Loading...
HomeMy WebLinkAboutAQ_F_0800044_20221208_ST_ProtRvw_2022-261p �t,.c STATE`u� ROY COOPER Governor ELIZABETH S.BISER Secretary rf$ ^P µ* MICHAEL ABRACZINSKAS NORTH CAROLINA Director Environmental Quality December 8,2022 Mr. Brian Conner,Environmental Health& Safety Manager Avoca LLC P.O. Box 129 Merry Hill,NC 27957-0129 Subject: Avoca LLC—(841 Avoca Farm Road) Merry Hill,Bettie County,North Carolina Protocol for Particulate Matter(PM),Hydrogen Chloride (HCI), Carbon Monoxide (CO), and Mercury(Hg)Emissions Testing Biomass Boilers ES-BB1 and ES-BB2 Proposed Test Date: December 13,2022, To Be Performed by Integrity Air Monitoring,Inc. Facility ID 0800044,Air Permit No. 01819T53,Tracking No. 2022-261ST Dear Mr. Conner: The North Carolina Division of Air Quality(DAQ)has reviewed the protocol submittal form(PSF)for the emissions testing of biomass boilers ES-BB 1 and ES-BB2. Integrity Air Monitoring has proposed EPA Method 5 for particulate matter(PM),EPA Method 26A for hydrogen chloride(HCl),EPA Method 10 for carbon monoxide(CO), and EPA Method 30B for mercury(Hg). The proposed testing is acceptable for demonstrating compliance with the applicable regulations. ES-BB 1 and ES-BB2 are two biomass/bio-based solids-fired boilers(24 million Btu per hour maximum permitted heat input rate each) controlled by bagfilter CD-BB 1BH. 15A NCAC 2D .0503 Particulates From Fuel Burning Indirect Heat Exchangers and 40 CFR 63 Subpart DDDDD National Emissions Standards for Hazardous Air Pollutants for Industrial, Commercial, and Institutional Boilers and Process Heaters apply to the biomass boilers. The emissions limits and regulations are shown in the table below. Table 1: Testing Methods and Limits for each Boiler Tested EPA Target Method Run Time Emission Limit Regulation Volumetric Flow Rate Molecular Weight and 4 with Methods 5,26A,30B ___ ___ 1,2,3A 3 runs Concurrent Moisture Content 0.33 lb/MMBtu of heat input 15A NCAC 2D .0503 Filterable PM 5 3 runs, 120 minutes each Permit Section 2.1 E.l.a (minimum 2 dscm/run)* 3.0E-02 lb/MMBtu of heat input CO 10 3 runs,60 minutes each 620 ppmvd @ 3%02 3 runs,60 minutes each 40 CFR 63 Subpart DDDDD Hg 30B minimum sample as specified in 8.0E-07 lb/MMBtu of heat input Permit Section 2.1 E.5.f the method* 3 runs, 120 minutes each HCl 26A (26A minimum 1 dscm/run)*or 2.2E-02 lb/MMBtu of heat input (5/26A minimum 2 dscm/run)* * Collect a minimum sample volume as specified. Note: As proposed sampling will be performed via a combined Method 5/26A sample train. Thus,tester must meet the more restrictive method requirements of each of the two methods(i.e.,temperatures and sample volumes). Test period heat input rates to be determined using the EPA Method 19 for wood(Fd=9,240 dscf/MMBtu). DE Q� North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh,North Carolina 27699-1641 N09J I'>CA%OUNA 0"a�orEnyGn uftIOLmlI\ 919.707.8400 Mr. Brian Conner,Environmental Health& Safety Manager December 8,2022 Page 2 (Avoca LLC-Boilers ES-BB 1 and ES-BB2,40 CFR 63 Subpart DDDDD MACT Testing) The final test report should include information to establish that the testing performed was near maximum normal or approximately>90%of maximum normal. The proposed test process rate for boiler ES-BB 1 and ES-13132 is approximately 21.6 MMBtu/hr each. The applicable test period monitoring parameters should also be included in the final report. The proposed testing is acceptable for demonstrating compliance with the applicable regulations. Approval of the proposed methods does not exempt the tester from the minimum requirements of the applicable test methods. Any deviations from the applicable methods remain subject to approval by DAQ. If there are questions concerning this matter,please contact me at(919) 707-8415 or gregg.onealgricdenn gov. Sincerely, f Thomas G. O'Neal,111,P.E.,Environmental Engineer Division of Air Quality,NCDEQ cc: James Lewis,Integrity Air Monitoring,Inc. -Huntersville,NC Betsy Huddleston,Washington Regional Office Laserfiche -0800044 �t,.c STATE`u� ROY COOPER Governor ELIZABETH S.BISER Secretary rf$ ^P µ* MICHAEL ABRACZINSKAS NORTH CAROLINA Director Environmental Quality December 8,2022 Mr. Brian Conner,Environmental Health& Safety Manager Avoca LLC P.O. Box 129 Merry Hill,NC 27957-0129 Subject: Avoca LLC—(841 Avoca Farm Road) Merry Hill,Bettie County,North Carolina Protocol for Particulate Matter(PM),Hydrogen Chloride (HCI), Carbon Monoxide (CO), and Mercury(Hg)Emissions Testing Biomass Boilers ES-BB1 and ES-BB2 Proposed Test Date: December 13,2022, To Be Performed by Integrity Air Monitoring,Inc. Facility ID 0800044,Air Permit No. 01819T53,Tracking No. 2022-261ST Dear Mr. Conner: The North Carolina Division of Air Quality(DAQ)has reviewed the protocol submittal form(PSF)for the emissions testing of biomass boilers ES-BB 1 and ES-BB2. Integrity Air Monitoring has proposed EPA Method 5 for particulate matter(PM),EPA Method 26A for hydrogen chloride(HCl),EPA Method 10 for carbon monoxide(CO), and EPA Method 30B for mercury(Hg). The proposed testing is acceptable for demonstrating compliance with the applicable regulations. ES-BB 1 and ES-BB2 are two biomass/bio-based solids-fired boilers(24 million Btu per hour maximum permitted heat input rate each) controlled by bagfilter CD-BB 1BH. 15A NCAC 2D .0503 Particulates From Fuel Burning Indirect Heat Exchangers and 40 CFR 63 Subpart DDDDD National Emissions Standards for Hazardous Air Pollutants for Industrial, Commercial, and Institutional Boilers and Process Heaters apply to the biomass boilers. The emissions limits and regulations are shown in the table below. Table 1: Testing Methods and Limits for each Boiler Tested EPA Target Method Run Time Emission Limit Regulation Volumetric Flow Rate Molecular Weight and 4 with Methods 5,26A,30B ___ ___ 1,2,3A 3 runs Concurrent Moisture Content 0.33 lb/MMBtu of heat input 15A NCAC 2D .0503 Filterable PM 5 3 runs, 120 minutes each Permit Section 2.1 E.l.a (minimum 2 dscm/run)* 3.0E-02 lb/MMBtu of heat input CO 10 3 runs,60 minutes each 620 ppmvd @ 3%02 3 runs,60 minutes each 40 CFR 63 Subpart DDDDD Hg 30B minimum sample as specified in 8.0E-07 lb/MMBtu of heat input Permit Section 2.1 E.5.f the method* 3 runs, 120 minutes each HCl 26A (26A minimum 1 dscm/run)*or 2.2E-02 lb/MMBtu of heat input (5/26A minimum 2 dscm/run)* * Collect a minimum sample volume as specified. Note: As proposed sampling will be performed via a combined Method 5/26A sample train. Thus,tester must meet the more restrictive method requirements of each of the two methods(i.e.,temperatures and sample volumes). Test period heat input rates to be determined using the EPA Method 19 for wood(Fd=9,240 dscf/MMBtu). DE Q� North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh,North Carolina 27699-1641 N09J I'>CA%OUNA 0"a�orEnyGn uftIOLmlI\ 919.707.8400 Mr. Brian Conner,Environmental Health& Safety Manager December 8,2022 Page 2 (Avoca LLC-Boilers ES-BB 1 and ES-BB2,40 CFR 63 Subpart DDDDD MACT Testing) The final test report should include information to establish that the testing performed was near maximum normal or approximately>90%of maximum normal. The proposed test process rate for boiler ES-BB 1 and ES-13132 is approximately 21.6 MMBtu/hr each. The applicable test period monitoring parameters should also be included in the final report. The proposed testing is acceptable for demonstrating compliance with the applicable regulations. Approval of the proposed methods does not exempt the tester from the minimum requirements of the applicable test methods. Any deviations from the applicable methods remain subject to approval by DAQ. If there are questions concerning this matter,please contact me at(919) 707-8415 or gregg.onealgricdenn gov. Sincerely, f Thomas G. O'Neal,111,P.E.,Environmental Engineer Division of Air Quality,NCDEQ cc: James Lewis,Integrity Air Monitoring,Inc. -Huntersville,NC Betsy Huddleston,Washington Regional Office Laserfiche -0800044