Loading...
HomeMy WebLinkAboutAQ_F_0400056_20210301_CMPL_CompRpt REVIEW OF TITLE V 2020 ANNUAL COMPLIANCE CERTIFICATION Reviewer Assigned: GREG REEVES FACILITY PIEDMONT NATURAL GAS FACILITY 0400056 NAME: WADESBORO COMPRESSOR STATION ID: l. Is the Certification sheet signed by the authorized/responsible official? Y❑ N ❑ 2. Print the"Summary of Violations for a Facility"report from IBEAM and attach. a 3. Are all NOD/NOV/NREs accounted for in the Deviation Summary Report? Y❑ N N/A 4. If deviations are noted, did FRO address them all?(i.e. send letter)? Check paper file for any issues that may not be recorded in IBEAM Violations. Y F-1 N 1-1 N!A ❑� 5. Discuss deviations details with Compliance Coordinator. Y❑ N/A F,/] 6. If there was more than one permit applicable during the year, have all the permits been addressed in this ACC? Permit Numbers 10097T02 Y❑ N ❑ N1AFV-1 7. Do reported sources and conditions match those in the permit(s)? Y F,/] N ❑ 8. Is the Compliance Summary Report for Specific Conditions complete and accurate? Y[1-4 N ❑ 9. Is the Compliance Summary Report for General Conditions complete and accurate? Y❑� N ❑ 10. Is compliance with the ACC requirements indicated? Y F7 N ❑ 11. Record in IBEAM Actions/Reporting(date received, date reviewed,compliance status,comments). Completed on 03/10/2021 (date) REMEMBER—Compliance determination here refers to the ACC submitting requirements(late, not submitted, incomplete, etc). Talk to the Compliance Coordinator before you code a facility in violation. 12. Initial and date the top of the ACC Certification Sheet(not this cover sheet). Fv/1 13. File FRO copy in a"Reports"or an"ACC"folder in facility file after Compliance Coordinator review. 14. Comments: Reviewed by: _ C 2U2 Date: 0311012021 initials Coordinator Review: 17e D 0311012021 � ate (initials) 0 Page 1 of 1 3/10/2021 Summary of Violations Violator: P EO�0� b�aAL 6AS - A Facility I OqO n v 56 Letter Date77 iolation(s): County: Letter Type: Case#: Date Assessed: Amount Assessed: i Case Closed: Total Amount Paid : j '10 N o 20 vO i Piedmont Natural Gas February 22,2021 Air and EPCRA Enforcement Branch RECEIVED U.S. Environmental Protection Agency Region 4 MAR - 1 2021 61 Forsyth Street, SW Atlanta,GA 30303 DEQ-FAYETTEVILLE REGIONAL Subject: 2020 Annual Compliance Certification PO 2�zL LI Piedmont Natural Gas Company, Inc.—Wadesboro Compressor Station Wadesboro,North Carolina; Anson County Title V Permit No. 10097T; Facility ID 0400056 To Whom It May Concern: Piedmont Natural Gas Company, Inc. (Piedmont)operates a compressor station located at 379 Pleasant Grove Church Road, Wadesboro, Anson County,North Carolina (Wadesboro Compressor Station). The Wadesboro Compressor Station operated under North Carolina Division of Air Quality(DAQ)Title V Permit No. 10097T02 during the 2020 reporting year. Piedmont is submitting this 2020 CY Annual Compliance Certification by March 1,2021 in accordance with General Condition 3.P.of the Title V permit. The required Annual Compliance Certification form is included as Attachment 1. The Permit Conditions Summary table indicating the compliance status of the federally- enforceable permit conditions is included as Attachment 2 to this letter. The Compliance Summary for the general permit conditions is included in Attachment 3. The facility did not experience any deviations during the period from January 1,2020 through December 31,2020. PIease contact Kristen Belisario at(440)668-8785 or via email at kristenkristen.belisario,:ci duke-eners�eners�if you have any questions concerning this complimnce certification. Sincerely, Adam B. Long,P.E. tt VP,Gas Pipeline Operations cc: Heather Carter,Regional Supervisor Fayetteville Regional P.O,Box 33068 - Charlotte,North Carolina 28233 pledmontng.com North Carolina Department of Environmental Quality Division of Air Quality(DAQ) Title V Annual Compliance Certification Forms Facility Name: Piedmont Natural Gas Company,Inc.-Wadesboro Compressor Station Facility Location: 379 Pleasant Grove Church Road,Wadesboro,NC Facility ID Number: 0.100056 (Refer to first page of Title V Permit) Title V Permit Number: 10097T2 (Refer to first page of Title V Permit) Start of Reporting Period: January 1,2020 (Month, Day,Year) End of Reporting Period: December 31,2020 (Month,Day,Year) Compliance Statement(Check only one of the following options) X During the reporting period specified above,this facility was in compliance with all terms and conditions identified in the above referenced Title V Operating Permit. As such,there were no deviations2,excess emissions events,or other reportable incidents including those attributable to equipment malfunctions,breakdown,or upset conditions (please fill out the Compliance Summary Report). During the reporting period specified above,this facility was in compliance with ALL terms and conditions identified in the above referenced Tide V Operating Permit,EXCEPT for the deviations identified in the Deviation Summary Report(please fill out both the Compliance Summary Report and Deviation Summary Report). Does the above compliance statement differ from what is indicated on your most recent Title V Report(i.e.,last Semi- Annual Monitoring Report,Annual Emissions Inventory,etc.)? O Yes (7) No Are you submitting this Annual Compliance Certification form to also fulfill a Title V Semi-Annual Monitoring reporting requirement? If so,this certification must be submitted by January-30. O Yes O No Certification By Responsible Official Based on information and belief formed after reasonable inquiry,the undersigned certified under penalty of law(federal rule 40 CFR 70.5(d))that all information and statements provided in this form(including any attachments)are true,accurate,and complete. (Signature of Responsible Official) (Date) Name Adam B. Long, P.E. (Type or Print) Number of Attached Pages(not including Instructions Page) 19 i An annual compliance certification(ACC)is required pursuant to federal rule 40 CFR 110.6(c),state rules ISM!NCAC Sections?Q 0308rt)and 2Q.0508(bb),and Section 3-General Condition P of the Title V Operaling Permit A copy of your ACC is to be submitted to both the N arth Carolina DAQ and the U.S EPA(Air and EPCRA Enforcement Branch,EPA,Region 4,61 Forsyth Street,Atlanta,GA 30303). The submittal date for the ACC is specified in Section 3-General Condition P ofyour Title Vpermit For the purposes of this form,the term "deviation"means anv action or circumstance not in accordance with the terms and conditions of the Title C Operating Permit including those attributable to equipment malfunction,breakdown.or upset conditions and'or excess emissions events The ackno►i ledgemeni of deviattons from specific permit requirements is not necessarily an acknowledgement of a violation.However,failure to report am,and all deviations mm,constitute a violation of the Title V operating Permit and the underlying emission standard.For more information about deviations, please refer to the DAQ memorandum outlining the definition of deviation for Title Vreportingon the DAQ web site(hip deq nc gov about divisions air- qualit)-Air-quality-enforcenienilexcess-emissions-deviations-malfunction-determinations) Revision 3.0 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 Terms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining Omission Source Description Device ID Condition Condition Summary (Yes/No) Maintained? non-compliance Compliance Status (comments (Yes/NO/NA) Issue. (Yes/No) Number(s) No.10097T2 15A NCAC 2D.0516: No monitoring/ Sulfur Dioxide recordkeeping/reporting is 2.I.A.l Emissions From No N. N A Use of natural gas only. required for sulfur dioxide Combustion Sources emissions from the firing of natural gas. 15A NCAC 2D.0521: No monitoring/ Eight(8)four-stroke lean burn 2.1.A.2 Control of Visible No NA NA Use of natural gas only. recordkeeping/reporting is natural gas-fired reciprocating required for visible emissions COMP 01- internal combustion engines(4,735 COMP08, Emissions from the firing of natural gas. horsepower rating each)powering I COMPO 1 C- eight compressors each equipped Compliance with the 30-day with a catalytic oxidizer(at least 24 COMP08C rolling average emissions of 125 Piedmont complied with the ft3 of oxidation catalyst) ppm and the alternative 3 rolling average 15A NCAC 2D.1423: monitoring and recordkeeping emission ssion limit all times 2.1.A.4 Large Internal No Yes NA plan including submission of and submitted a timely ozone Combustion Engines NOx emissions during ozone season report. All specified records are maintained on- season from May 1-September 30 by October 31 of each year. site for a period of at least five years. Attachment 2-Page 2 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT- Permit No. 10097T02 For Calendar Year 2020 "Perms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining Emission Source Description Device ID Condition Condition Summary (Yes/No) Maintained? non-compliance Compliance Status Comments Issue?(Yes/No) Number(s) No.10097T2 15A NCAC 2D Compliance with this .0524:New Source Units meet all applicable condition is demonstrated by 2.1.A.3.a Performance Standards No Ycs NA provisions under 40 CFR 60 meeting the emission [40 CFR 60 Subpart Subpart JJJJ. standards in condition JJJJ] 2.2.A.2.b through 2.2.A.2.k. COMP05-COMP08 have not yet commenced construction. Initial performance testing for Eight(8)four-stroke lean burn 15A NCAC 2D COMPOI-COMP04 was natural gas-fired reciprocating COMPO 1- .0524:New Source Comply with general provisions conducted in February 2014 internal combustion engines(4,735 of 40 CFR 60 Subpart A as and subsequent testing was horsepower rating each powering COMP08, 2.1.A.3.b Performance Standards No Yes NA p g )po g presented in Table 3 of 40 CFR conducted in August 2016. eight compressors each equipped COMPOIC- [40 CFR 60 Subpart 60 Subpart JJJJ Performance testing was with a catalytic oxidizer(at least 24 COMP08C JJJJ] completed August 6,2019 on 113 of oxidation catalyst) COMPOI.Results demonstrated compliance with 40 CFR 60 Subpart JJJJ Table 1. Compliance with emission performance testing for 15A NCAC 2D standards in 40 CFR 60 Subpart .0524:New Source JJJJ,Table I(Non-Emergency CO gustPOI was performed9adto on August 6,2019 and test 2.1.A.3.c Performance Standards No Yes NA SI Engine,HP>500, results demonstrated [40 CFR 60 Subpart manufacture date after JJJJ] 7/I/2010)by conducting initial compliance with emission and subsequent stack testing. limits. Attachment 2-Page 3 of 19 I North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 Terms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining k�:mission Source Description "Device ID Condition Condition Summary (Yes/No) Maintained? non-compliance Compliance Status Comments Issue. (Yes/No) Number(s) No.10097'1'2 15A NCAC 2D Testing shall be performed in Performance testing for .0524:New Source accordance with General COMPOI was performed on 2.1.A.3.d Performance Standards No Yes NA Condition JJ;and each August 6,2019 and test [40 CFR 60 Subpart performance test shall follow results demonstrated JJJJ] the procedures in 60.4244 compliance with emission limits. A copy of the maintenance Non-Certified engine:keep plan and recorded maintenance plan,maintain maintenance is maintained 15A NCAC 2D on-site. Initial performance Eight(8)four-stroke lean burn .0524:New Source records of conducted testing was conducted in natural as-fired reciprocating maintenance. Conduct initial g P g 2.1.A.3.e Performance Standards No Yes NA February 2014 and internal combustion engines 4,735 COMPOI- performance tests and g ( [40 CFR 60 Subpart subsequent testing was horsepower rating each)powering COMP08, JJJJ subsequent performance tests conducted in August 2019. eight compressors each equipped COMPOIC- � every 8,760 hours or 3 years, Results demonstrated with a catalytic oxidizer(at least 24 COMP08C whichever comes first. compliance with 40 CFR 60 113 of oxidation catalyst) Subpart JJJJ Table 1. 15A NCAC 2D .0524:New Source Operate and maintain the Units are operated and 2.l.A.3.f Performance Standards No Yes NA stationary SI ICE to achieve the maintained to meet emission [40 CFR 60 Subpart emission standards as required standards over the life of iiiii over the entire life of the engine each engine. 15A NCAC 2D The AFR controllers are used .0524:New Source Maintain and operate air-to-fuel and proper operation of the 2.1.A.3.g Performance Standards No Yes NA ratio(AFR)controller to ensure engines and corresponding [40 CFR 60 Subpart proper operation of the engine catalytic oxidizers is JJJJ and control device. maintained. Attachment 2-Page 4 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 Terms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining Emission Source Description Maintained? non-compliance Comments Device ID Condition Condition Summary (Yes/No) (Yes/No/NA) Issue?(Yes/No) Compliance Status Number(s) No.10097 T2 Maintain records and supporting 15A NCAC 2D documentation for all .0524:New Source notifications,reports, All required records are 2.1.A.3.h Performance Standards No Yes NA performance tests,and [40 CFR 60 Subpart maintenance records that show maintained on-site. JJJJ] compliance with emission standards. 15A NCAC 2D .0524:New Source Initial notifications were 2.1.A.3.i Performance Standards No Yes NA Submit initial notifications. submitted and captured under Eight(8)four-stroke lean burn [40 CFR 60 Subpart previous ACC submittals. JJJJ natural gas-fired reciprocating COMPOI- All required records are internal combustion engines(4,735 COMP08, maintained on-site. horsepower rating each)powering COMPOI C- Maintain records and supporting Initial notification for eight compressors each equipped COMP08C documentation for all COMPO I-COMP04 was with a catalytic oxidizer(at least 24 15A NCAC 2D notifications,reports, submitted no later than 30 ft3 of oxidation catalyst) .0524:New Source performance tests,and days after construction. 2.1.A.3.1 Performance Standards No Yes NA maintenance records that show Performance testing for [40 CFR 60 Subpart compliance with emission COMP01 was conducted in JJJJ] standards. Submit performance August 6,2019 and the test reports within 60 days of performance test report was test completion. submitted September 20, 2019,within 60 days of test completion. 15A NCAC 2D 015A New Source Submit summary reports of Semiannual reports were 2.1.A.3.k Performance Standards No Yes NA monitoring and recordkeeping submitted in a timely manner [40 CFR 60 Subpart activities 30 days after the end and included all required JJJJ of the semiannual period. elements. Attachment 2-Page 5 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 Terms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining Emission Source Description Device 1D Condition Condition Summary (Yes/No) Maintained? non-compliance Compliance Status Comments (Yes/No/NA) issue?(Ves/No) Number(s) No.10097T2 15A NCAC 2D.0516: No monitoring/ Sulfur Dioxide recordkeeping/reporting is 2.1.B.1 Emissions From No N' NA Use of natural gas only. required for sulfur dioxide Combustion Sources emissions from the firing of natural gas. 15A NCAC 2D.0521: No monitoring/ recordkeeping/reporting is 2.1.B.2 Control of Visible No NA NA Use of natural gas only. required for visible emissions Emissions from the firing of natural gas. 15A NCAC 2D Compliance with this .0524:New Source Units meet all applicable condition is demonstrated by 2.1.B.3.a Performance Standards No Yes NA provisions under 40 CFR 60 meeting the emission One(1)four-stroke lean burn natural [40 CFR 60 Subpart Subpart JJJJ. standards in condition gas-fired emergency generator(880 EG-01 iiiij 2.I.B.2.b through 2.1.13.21. hp maximum rating) 15A NCAC 2D Comply with general provisions .0524:New Source 2.1.B.3.b Performance Standards No Yes NA of 40 CFR 60 Subpart A as [40 CFR 60 Subpart presented in Table 3 of 40 CFR Compliance with this JJJJ 60 Subpart JJJJ condition is demonstrated by meeting the emission 15A NCAC 2D .0524:New Source Comply with emission limits as standards in the following conditions. 2.1.B.3.c Performance Standards No Yes NA presented in Table 1 of 40 CFR [40 CFR 60 Subpart 60 Subpart JJJJ JJJJ 15A NCAC 2D Testing shall be performed in .0524:New Source accordance with General Testing was completed for EGO1 was conducted May 2.1.B.3.d Performance Standards No Yes NA Condition JJ;and each 2019 and followed the [40 CFR 60 Subpart performance test shall follow required procedures. JJJJ the procedures in 60.4244 Attachment 2-Page 6 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 "Perms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining Emission Source Description . Device ID Condition Condition Summary (Yes/Nt►) Maintained? non-compliance Compliance Status Comments (Yes/No/NA) Issue?(Yes/No) Number(s) No.10097T2 15A NCAC 21) The emergency engine is .0524:New Source The engine shall be equipped equipped with a non- with a non-resettable hour meter resettable hour meter. 2.1.B.3.e Performance Standards No Yes NA 140 CFR 60 Subpart if manufactued after July 1, Records are maintained on- JJJJ] 2010 site. A copy of the maintenance Non-Certified engine:keep plan and recorded maintenance plan,maintain maintenance is maintained One(1)four-stroke lean burn natural 15A NCAC 21) records of conducted on-site. Initial performance gas-fired emergency generator(880 EG-01 0524:New Source maintenance. Conduct initial testing was conducted in hp maximum rating) 2.1.B.3.f Performance Standards No Yes Nn performance tests and February 2014 and [40 CFR 60 Subpart subsequent testing was Jim] conducted performance tests conducted in May 2019. every 8,760 hours or 3 years, Results demonstrated whichever comes first. compliance with 40 CFR 60 Subpart JJJJ Table 1. 15A NCAC 21) .0524:New Source Operate and maintain the Units are operated and 2.1.B.3.g Performance Standards No Yes NA stationary SI ICE to achieve the maintained to meet emission [40 CFR 60 Subpart emission standards as required standards over the life of JJJJ over the entire life of the engine each engine. Attachment 2-Page 7 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 Terms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining Emission Source Description Device ID Condition Condition Summary (Yes/No) Maintained? non-compliance Compliance Status Comments Number(s) No.10097T2 (Yes/No/1�A) Issue. (Yes/No) Limit emergency engine operation to 100 hrs/yr for Hours of operation of the maintenance and testing, emergency engine are emergency demand response, recorded using the non- and operation in non-emergency resettable hour meter. Hours 15A NCAC 2D situations. Operation in non- of operation during CY 2020 .0524:New Source emergency situations is limited did not exceed the 50 hr/yr 2.1.B.3.h Performance Standards No Yes NA to 50 hrs/yr,and is counted limitation for operation in [40 CFR 60 Subpart towards the as part of the 100 non-emergency situations,or JJJJ] hrs/yr total. Maintain records of the 100 hr/yr limitation for runtime during emergency maintenance and testing and situations,non-emergency operation in non-emergency situations,and periods of situations. Records are maintenance and readiness maintained on-site. testing. One(1)four-stroke lean burn natural Maintain records and supporting gas-fired emergency generator(880 EG-01 15A NCAC 2D documentation for all hp maximum rating) .0524:New Source notifications,reports, All required records are 2.1.13.31 Performance Standards No Yes NA performance tests,and maintained on-site. [40 CFR 60 Subpart maintenance records that show JJJJ] compliance with emission standards. 15A NCAC 2D .0524:New Source Initial notification is not 2.1.B.3.j Performance Standards No Yes NA required for emergency NA [40 CFR 60 Subpart stationary SI ICE. JJJJ 15A NCAC 2D Performance testing for the .0524:New Source Submit copy of each emergency engine was 2.1.13.31 Performance Standards No Yes NA performance test as conducted submitted June 17,2019 and [40 CFR 60 Subpart in 60.4244 within 60 days after demonstrated compliance JJJJ] the test has been completed. with 40 CFR 60 Subpart JJJJ. Attachment 2-Page 8 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 Terms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)ol'Determining Emission Source Description Maintained? non-compliance Comments Device ID Condition Condition Summary (Yes/No) (Yes/No/NA) Issue?(Yes/No) Compliance Status Number(s) No.10097T2 15A NCAC 2D Submit summary reports of Semiannual reports were One(1)four-stroke lean burn natural .0524:New Source monitoring and recordkeeping submitted in a timely manner gas-fired emergency generator(880 EG-01 2.1.13.3.1 Performance Standards No Y C', NA activities 30 days after the end and included all required hp maximum rating) [40 CFR 60 Subpart of the semiannual period. elements. JJJJ Eight(8)four-stroke lean burn 15A NCAC 2D.I 111: Compliance with 40 CFR Part There are no requirements Maximum Achievable uirements natural as-fired reciprocating 63 Subpart ZZZZ by complying for these emission sources g p g 2.2.A.1 Control Technology[40 No Nn NA with 40 CFR Part 60 Subpart under Sub art ZZZZ. No internal combustion engines(4,735 COMPOI- CFR Part 63,Subpart p p horsepower rating each)powering ZZZZ] JJJJ• further requirements apply. eight compressors each equipped COMP with a catalytic oxidizer(at least 24 COMPOIC- COMP08C, ft3 of oxidation catalyst)and EG-01 One(1)four-stroke lean burn natural gas-fired emergency generator(880 hp maximum rating) 15A NCAC 2D.0524: Compliance with this New Source Units meet all applicable condition is demonstrated by -- Performance Standards No Yes NA provisions under 40 CFR 60 meeting the emission [40 CFR 60 Subpart Subpart JJJJ. standards in condition JJJJ] 2.2.A.2.b through 2.2.A.2.s. Attachment 2-Page 9 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT- Permit No. 10097T02 For Calendar Year 2020 'Perms and Conditions Source or Records Was Deviation a Control Permit Deviations? (Yes/No/NA) Issue?(Yes/No) Method(s)of Determining Comments Emission Source Description Device ID Condition Condition Summary (Yes/No) Maintained? non-compliance Compliance Status Number(s) No,10097T2 COMP05-COMP08 have not yet commenced construction. Initial Compliance with emission performance testing for 15A NCAC 2D.0524: standards in 40 CFR 60 Subpart COMPOI -COMP04 was conducted in February 2014 New Source JJJJ,Table 1 (Non-Emergency and subsequent testing was -- Performance Standards No Yes NA SI Engine,HP>500, [40 CFR 60 Subpart manufacture date after conducted in August 2016 ] 7/1/2010 JJJJ and performance testing for Eight(8)four-stroke lean burn )by conducting initial COMPOI was conducted in natural gas-fired reciprocating and subsequent stack testing. August 6,2019.. Results internal combustion engines(4,735 horsepower rating each)powering COMP01- demonstrated compliance COMP08, with 40 CFR 60 Subpart JJJJ eight compressors each equipped with a catalytic oxidizer(at least 24 COMPOIC- Table I. ft3 of oxidation catalyst)and COMP08C, g Not Applicable. All engines Compliance with field testing One(1)four-stroke lean burn natural EG-01 -- p g. q at the Wadi s ion facility No NA NA provisions for en mes re wired meet the emission standards gas-fired emergency generator(880 to meet standards referenced in in 40 CFR 60 Subpart JJJJ, hp maximum rating) 15A NCAC 2D.0524: 40 CFR 1048.101. Table 1. New Source Units are operated and Performance Standards Units meet all applicable No Yes NA provisions under 40 CFR 60 maintained to meet emission [40 CFR 60 Subpart standards over the life of JJJJ] Subpart JJJJ. each engine. After July 1,2009,do not install All engines>_500 HP were -- No Yes NA SI ICE>500 HP that do not installed after July 1,2009 meet the applicable and meet the applicable requirements of§60.4233. requirements of '60.4233. Attachment 2-Page 10 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 "Perms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining Emission Source Description Comments Device ID Condition Condition Summary (Yes/No) Maintained? non-compliance Compliance Status Number(s) No,10097'1'2 (Yes/No/NA) Issue?(YesfNo) A copy of the maintenance plan and recorded Non-Certified engine:keep maintenance is maintained 15A NCAC 2D.0524: maintenance plan,maintain on-site. Initial performance New Source records of conducted testing for COMPOI- -- Performance Standards No Yes NA maintenance. Conduct initial COMP04 was conducted in [40 CFR 60 Subpart performance tests and February 2014 and JJJJ] subsequent performance tests subsequent testing was every 8,760 hours or 3 years, conducted in August 2016. whichever comes first. Results demonstrated compliance with 40 CFR 60 Eight(8)four-stroke lean burn Subpart JJJJ Table 1. natural gas-fired reciprocating The AFR controllers are used internal combustion engines(4,735 Maintain and operate air-to-fuel and proper operation of the horsepower rating each powering COMPOI- ratio(AFR)controller to ensure horse p g ) g COMP08, -- No Yes NA engines and corresponding eight compressors each equipped proper operation of the engine catalytic oxidizers is with a catalytic oxidizer(at least 24 COMPOIC- and control device.COMP08C, maintained. 113 of oxidation catalyst)and EG-01 One(1)four-stroke lean burn natural gas-fired emergency generator(880 15A NCAC 2D.0524: Conduct initial stack testing to Subsequent performance testing for the emergency hp maximum rating) New Source meet the emission limit for -- Performance Standards No Yes N A emergency stationary ICE in 40 engine was conducted in May 2019 and demonstrated [40 CFR 60 Subpart CFR 60 Subpart JJJJ Table 1 JJJJ] (Emergency z 130 HP). compliance with 40 CFR 60 Subpart JJJJ. Performance testing was Conduct performance testing in conducted in May 2019 for -- No Yes NA accordance with§60.4244 of EGO and in August 2019 Subpart JJJJ. for COMPOI and test results demonstrated compliance with emission limits. Attachment 2-Page 11 of 19 of Environmental Quality North Carolina Department � y Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 Terms and Conditions Source or Records Was Deviation a Control Permit Deviations'' Method(s)of Determining Emission Source Description Device 1D Condition Condition Summary (Yes/No) Maintained? non-compliance Com Hance Status Comments Number(s) No.10097'1'2 (Yes/No/NA) Issue?(Yes/No) p All required records are maintained on-site. Initial notification for COMPOI-COMP04 was Maintain records and supporting submitted no later than 30 documentation for all days after construction. Performance testing for notifications,reports, EGO was conducted on May Eight(8)four-stroke lean burn performance tests,and 2019 and the performance natural gas-fired reciprocating -- No Yc, NA maintenance records that show test report was submitted e internal combustion engines(4,735 compliance with emission June report within 60 days n horsepower rating each werinof COMPOI- 15A NCAC 2D.0524: standards. Submit initial P g )Po g test completion. eight compressors each equipped COMP08, New Source notifications. Submit 1� PCOMPOI C- Performance Standards Performance testing for with a catalytic oxidizer at least 24 performance test reports within � ( 40 CFR 60 Subpart COMP014 was conducted in 3 COMPOBC, [ P 60 days of test completion. ft of oxidation catalyst)and EG-01 JJJJ] August 2019 and the One(1)four-stroke lean burn natural performance test report was gas-fired emergency generator(880 submitted September hp maximum rating) 20,2019,within 60 days of test completion. The emergency engine is Equip the emergency engine equipped with a non- No Y cs NA with a non-resettable hour meter resettable hour meter. prior to startup. Records are maintained on- site. Attachment 2-Page 12 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT- Permit No. 10097T02 For Calendar Year 2020 "Perms and Conditions Source or Records Was Deviation a Control Permit Deviations? Method(s)of Determining Emission Source Description Maintained? non-compliance Comments Device 1D Condition Condition Summary (Yes/No) p Com lianee Status Number(s) No.10097T2 (Yes/No/NA) Issue?(Yes/No) COMP05-COMP08 have Non-Certified engine:keep not yet commenced -- No Yes NA maintenance plan,maintain construction. A copy of the records of conducted maintenance plan and maintenance. recorded maintenance is maintained on-site. Limit emergency engine Eight(8)four-stroke lean burn operation to 100 hrs/yr for Hours of operation of the natural gas-fired reciprocating maintenance and testing, emergency engine are internal combustion engines(4,735 emergency demand response, recorded using the non- horsepower rating each)powering COMPO , New Source 15A NCAC 2D.0524: and operation in non-emergency resettable hour meter. Hours eight compressors each equipped COMP08 situations. Operation in non- of operation during CY 2020 with a catalytic oxidizer(at least 24 COMPOIC, Performance Standards emergency situations is limited did not exceed the 50 hr/yr ft s of oxidation catalyst)and COMP08C __ [40 CFR 60 Subpart No Yes NA to 50 hrs/yr,and is counted limitation for operation in One(1)four-stroke lean burn natural EG-01 JJJJ] towards the as part of the 100 non-emergency situations,or gas-fired emergency generator(880 hrs/yr total. Maintain records of the 100 hr/yr limitation for hp maximum rating) runtime during emergency maintenance and testing and situations,non-emergency operation in non-emergency situations,and periods of situations. Records are maintenance and readiness maintained on-site. testing. Limit propane usage for the emergency engine to less than No propane was burned by -- No Yes NA the emergency engine in CY 100 hours per year during 2019. emergency operations. Non-Certified engine <500 Not Applicable. All engines HP:Conduct an initial at the Wadesboro facility are performance test and conduct greater than 500 HP in size. -- No NA NA subsequent performance tests if Initial and subsequent the stationary engine is rebuilt performance tests for EGO or undergoes major repair or are conducted in accordance maintenance. with§60.4243(b)(2)(ii). Attachment 2-Page 13 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-Permit No. 10097T02 For Calendar Year 2020 "terms and Conditions Source or Records Was Deviation a Emission Source Description Control Permit Deviations? 1N1aintained? non-compliance Method(s)of Determining Comments Device ID Condition Condition Summary (Ves/No) (yes/No/NA) Issue.?(Yes/No) Compliance Status Number(s) No.10097T2 iR(8)lour-stroke lean bum The AFR controllers are used natural gas-fired reciprocating Maintain and operate air-to-fuel and proper operation of the internal combustion engines(4,735 ratio(AFR)controller to ensure COMPOI- -- 15A NCAC 2D.0524: No Yes NA engines and corresponding horsepower rating each)powering proper operation of the engine COMP08 New Source catalytic oxidizers is COMPOIC- Performance Standards eight compressors each equipped and control device. maintained. with a catalytic oxidizer(at least 24 3 COMP08C, [40 CFR 60 Subpart Maintain records and supporting ft of oxidation catalyst)and EG-01 JJJJ] documentation for all One(1)four-stroke lean burn natural notifications,reports, All required records are hp maximum rating) gas-fired emergency generator(880 q -- N o Yes NA performance tests,and maintenance records that show maintained on-site. compliance with emission standards. Initial notification is not -- No NA NA required for emergency NA stationary SIICE. Submit summary reports of Semiannual reports were -- No Yes NA monitoring and recordkeeping submitted in a timely manner activities 30 days after the end and included all required of the semiannual period. elements. Eight(8)four-stroke lean burn natural gas-fired reciprocating CO is a surrogate for internal combustion engines(4,735 COMPOI- 15A NCAC 2Q.0317: Total annual emissions from formaldehyde. Compliance COMP08, horsepower rating each)powering Avoidance Conditions COMPOI-08 and EGO less with this condition is eight compressors each equipped than 10 tpy for a single HAP COMPOIC- 2.2.A.2 for HAP Major Source No Yes NA demonstrated by complying with a catalytic oxidizer(at least 24 COMP08C, Classification and less than 25 tpy for all with the CO monitoring, W of oxidation catalyst)and EG-01 Avoidance HAP,per consecutive 12-month recordkeeping,and reporting One(1)four-stroke lean burn natural period. of 2.2.A.2. gas-fired emergency generator(880 hp maximum rating) Attachment 2-Page 14 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-GENERAL CONDITIONS For Calendar Year 2020 Terms and Conditions Was Deviation a Records Deviations? ? non-compliance Method(s)of Determining Compliance Comments Condition Maintained. omments Condition Summary (Yes/No) (Yes/No/NA) Issue',� Status No. (Yes/No) 3.A General Provisions[NCGS 143-215& 15A No NA NA General Provisions acknowledged. NA NCAC 2Q.0508(i)(16)] 3.13 Permit Availability[15A NCAC 2Q No Yes NA Permit available on-site. NA .0507(k)&.0508(i)(9)(B)] 3.0 Severability Clause[15A NCAC 2Q No NA NA No administrative challenges. NA .0508(i)(2)] 3.13 Submissions[15A NCAC 2Q.0507(e)& No Yes NA Two copies of all documents and reports NA 2Q.0508(i)(16)] submitted. Records maintained on-site. 3.E Duty to Comply[15A NCAC 2Q No Yes NA Complied with all terms,conditions, NA .0508(i)(3)] requirements,limitations,and restrictions. Records maintained on-site. 3.G Permit Modifications[15A NCAC 2Q No Yes NA No changes. NA .0514,2Q.0524&2Q.0505,2Q.0515, 2Q.0516&2Q.0517] 3.11 Changes Not Requiring Permit No NA NA No changes. NA Modifications[15A NCAC 2Q.0523(a),2Q .0523(b)&2Q.0523(c)] 31A Reporting Requirements for Excess No NA NA No excess emissions or permit deviations NA Emissions and Permit Deviations[15A occurred during CY 2020.Records NCAC 2D.0535(f)and 2Q.508(f)(2)] maintained on-site. 3.1.13 Other Requirements under 15A NCAC 2D No NA NA No excess emissions occurred during CY NA .0535 2020. 3.J Emergency Provisions[40 CFR 70.6(g)] No NA NA No emergencies occurred during CY 2020. NA 3.K Permit Renewal[15A NCAC 2Q.0508(e) No NA NA No permit renewal required under 2Q.0500 NA and 2Q.0513(b)] during CY 2020. 3.L Need to Halt or Reduce Activity Not a No N A NA Not required. NA Defense[15A NCAC 2Q.0508(i)(4)] Attachment 3-Page 15 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-GENERAL CONDITIONS For Calendar Year 2020 'Perms and Conditions Was Deviation a Records Deviations? ? non-compliance Method(s)of Determining Compliance Permit Condition Yes/No) Maintained. Issue? Status Comments No. Condition Summary ( (Yes/No/NA) (Yes/No) 3.M Duty to Provide Information(submittal of No NA NA No information requested. NA information)[15A NCAC 2Q.0508(i)(9)] 3.N Duty to Supplement[15A NCAC 2Q No NA NA No information requested. NA .0507(f)] 3.0 Retention of Records[15A NCAC 2Q No Yes NA Records maintained on-site for a period of at NA .0508(f)and 2Q.0508(1)] least 5 years. 3.P Compliance Certification[15A NCAC 2Q No Yes NA This report serves as the Title V annual NA .0508(n)] compliance certification. 3.Q Certification by Responsible Official[15A No Yes NA Responsible Official signed all required NA NCAC 2Q.0520] Title V reports and submissions during CY 2020. 3.R Permit Shield for Applicable Requirements No NA NA Compliance with terms and conditions of the NA [15A NCAC 2Q.0512] permit. 3.S Termination,Modification,and Revocation No NA NA Not required. NA of the Permit 15A NCAC 2Q.0519 3.T Insignificant Activities[15A NCAC 2Q No Yes NA Insignificant activities documented in NA .0503] application and permit. Records maintained on-site. 3.U Property Rights[15 A NCAC 2Q No N A NA No rights conveyed by permit. N A .0508(i)(8)] 3.V Inspection and Entry[I 5A NCAC 2Q No N A NA Inspection and entry granted with NA .0508(1)and NCGS 143-215.3(a)(2)] credentials. 3.W Annual Fee Payment[15A NCAC 2Q No Yes NA Annual fee payment completed within 30 NA .0508(i)(10)] days after being billed. 3.X Annual Emission Inventory Requirements No Yes NA Emission inventory submitted by due date. NA [15A NCAC 2Q.0207] Attachment 3-Page 16 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-GENERAL CONDITIONS For Calendar Year 2020 'Perms and Conditions Records Was Deviation a Deviations? non-compliance Method(s)of Determining Compliance Permit Condition Yes/No) Maintained? Issue? Status Comments No Condition Summary ( (Yes/No/NA) (Yes/No) 3.Y Confidential Information[15A NCAC 2Q No NA NA No contidential intonnation submitted. NA .0107 and 2Q.0508(i)(9)] 32 Construction and Operating Permits[15A No NA NA There were no construction or operating NA NCAC 2Q.0100 and.0300] permit applications submitted during CY 2020. 3.AA Standard Application Form and Required No NA NA There were no construction or operating NA Information[15A NCAC 2Q.0505 and permit applications submitted during .0507] CY 2020. 3.1313 Financial Responsibility and Compliance No NA NA Not required. NA History[15A NCAC 2Q.0507(d)(4)] 3.CC Refrigerant Requirements(Stratospheric No Yes NA Complied with the requirements of 40 CFR NA Ozone and Climate Protection)[I 5A NCAC 82,as applicable. 2Q.0501(e)] 3.DD Prevention of Accidental Release-Section No NA NA The facility does not store any chemicals NA 112 r 15A NCAC 2Q.0508 h listed in 40 CFR 68.130. 3.EE Prevention of Accidental Release General No Yes NA The facility does not store any chemicals NA Duty Clause-Section I I2(r)(1)- listed in 40 CFR 68.130. FEDERALLY-ENFORCEABLE ONLY 3.FF Title IV Allowances[15A NCAC 2Q No NA NA Facility does not participate in Title IV. NA .0508(i)(1)] 3.GG Air Pollution Emergency Episode[15A No NA NA No emergency episodes occurred. NA NCAC 2D.0300] 3.HH Registration of Air Pollution Sources[15A No NA NA Not required. NA NCAC 2D.0202] 3.I1 Ambient Air Quality Standards 1 15A No NA NA Facility does not cause or contribute to NA NCAC 213.0501 c AAQS exceedances. Attachment 3-Page 17 of 19 North Carolina Department of Environmental Quality Division of Air Quality COMPLIANCE SUMMARY REPORT-GENERAL CONDITIONS For Calendar Year 2020 Terms and Conditions Was Deviation a Records Deviations? ? non-compliance Method(s)of Determining Compliance Permit Condition �es/No) Maintained. Issue? Status Comments No Condition Summary ( (Yes/No/NA) (Yes/No) _)j.1 General Emissions Testing and Reporting No Yes NA Performance testing for C0MPU1 was N;1 Requirements[15A NCAC 2Q.0508(i)(16)] conducted on August 2019 and testing for EGO was conducted May 2019. All testing was conducted in accordance with NSPS Subpart JJJJ requirements and General Condition 3.JJ. Performance test protocol and test reports were submitted as required. 3.K K Reopening for Cause[I 5A NCAC 2Q N o N A NA Not required. N A .0517 3.LL Reporting Requirements for Non-Operating No Yes NA Records of operation of all sources N A Equipment 15A NCAC 2Q.0508(i)(16) maintained on-site. 3.NN Specific Permit Modifications[15A NCAC No NA NA Not required. NA 2Q.0501 and.0523 3.00 Third Party Participation&EPA Review No NA NA Piedmont acknowledges EPA's right to a 45- NA [15A NCAC 2Q.0521,.0522,and day review period. .0525(7)] Attachment 3-Page 18 of 19 North Carolina Department of Environmental Quality Division of Air Quality DEVIATION SUMMARY REPORT For Calendar Year 2020 Page 1 of 1 Source or Deviation Deviation Suspected Cause of Corrective Action Emission Source Description Control Device Pollutant Deviation Description Date(s) Duration Deviation Taken 1D Number(s) No deviations occurred during the 2020 calendar year. Attachment 4-Page 19 of 19