Loading...
HomeMy WebLinkAboutAQ_F_1400226_20220222_CMPL_InspRpt NORTH CAROLINA DIVISION OF Asheville Regional Office AIR QUALITY Caldwell Cabinets of NC, LLC NC Facility ID 1400226 Inspection Report County/FIPS: Caldwell/027 Date: 02/22/2022 Facility Data Permit Data Caldwell Cabinets of NC, LLC Permit 10413/R00 3441 Hickory Blvd. SW Issued 12/9/2014 Hudson,NC 28638 Expires 11/30/2022 Lat: 35d 49.8832m Long: 81 d 27.3999m Class/Status Small SIC: 2434/Wood Kitchen Cabinets Permit Status Active NAICS: 33711 /Wood Kitchen Cabinet and Countertop Manufacturing Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP James Hamrick Amy Moore James Hamrick Operations Manager Member Officer Operations Manager (828)455-1842 (828)244-2975 (828)455-1842 Compliance Data Comments: Inspection Date 02/22/2022. Inspector's Name Bob Graves Inspector's Signature: it.e�Nam✓ Operating Status Operating Compliance Status Compliance -inspection Action Code FCE Date of Signature: 1 ` 1-z2 Inspection Result Compliance Total Actual emissions in TONS/YEAR: TSP S02 NOX VOC CO PM10 * HAP No emissions inventory on record.The emissions inventory is due 09/01/2022. * Highest HAP Emitted(in pounds) Five Year Violation History:None Date Letter Type Rule Violated Violation Resolution Date Performed Stack Tests since last FCE:None Date Test Results Test Method(s) Source(s)Tested Inspection Report: 1) Location: Caldwell Cabinets of NC, LLC is located at 3441 Hickory Blvd. SW in Hudson, NC. Caldwell County. Caldwell Cabinets of NC, LLC Page 2 Directions: From ARO, take I-40 east Jamestown Road exit 100. Follow Jamestown Rd. to Hwy 70 East. Follow to hwy 18/64. Follow 18/64 to Lenoir. In Lenoir turn right onto Southwest Blvd and go to end that joins into 321 South. Follow to Hudson and go past Mission Road red light and look on right for 3441 address. 2) Facility Overview Safety: safety shoes and glasses. Facility Contacts: correct as listed. Verified the contacts based on FACFINDER printout. Reba Walker is the new invoice contact with a mailing address at PO Box 547, Hudson,NC. Her e-mail address is: rwalker@caseworxnc.com. Overview: Caldwell Cabinets of NC is a woodworking facility that produces cabinets for industry. This facility is permitted under Air Permit No. 10413R00, effective from December 9, 2014, until November 30, 2022. Last compliance inspection was performed by Richard Morris on December 3, 2019. Current throughputs: 2021 Employees: 30 Hours of operation: 40-48 hrs./wk., 52 wks./yr. Inspection Observations: On February 22, 2022, I (Bob Graves) arrived at the facility. No dust or odors were observed offsite of the facility's property. I met with the facility contact, James Hamrick, Operations Manager. Mr. Hamrick gave a tour of the facility and access to records. The facility was operating on the day of inspection. All woodworking equipment are connected to the dust collection system and appeared to be in good condition. I observed the bagfilter while operating and found that it is currently venting to the inside of the building. The bagfilter's duct work and dust loading trailer appeared to be in good condition. The dry filter paint booth was not in operation. The spray booth filters are changed about every two weeks. Based on my conversation with Mr. Hamrick, we discussed the following: a) The facility's business was increasing in 2021, but has been slower so far in 2022. We also discussed their upcoming permit renewal. Process Description: Various tools including a cnc, table saws, and sanders are used to manufacture custom cabinets. Caldwell Cabinets of NC, LLC Page 3 3) Emission Source and Regulatory Review: Permitted Sources are: Emission Emission Source Control Control System Source ID F Description System ID Description ES-1 woodworking and dust collection system CD-1 one bag filter (1,607 square feet of filter area) Insignificant Sources: None Stipulation Review: A.2 Permit Renewal. Emission inventory and permit required 90 days prior to permit expiration. A.3 Particulate Control Requirement. The Permittee shall not discharge particulate matter caused by the working, sanding, or finishing of wood without providing, as a minimum for its collection, adequate duct work and properly designed collectors. In compliance. All woodworking equipment was connected to dust control system. The duct work inside and outside the building appeared to be in good condition. A.4 Visible Emissions. In compliance. No emissions observed. A.6 Fugitive Dust Control. In compliance. The only source for fugitive dust is the parking lot which is small, and gravel covered. A.7 Fabric Filter Requirements. In compliance. I reviewed their bagfilter logbook. I observed good record keeping documentation. The facility keeps records on bag filter replacement, maintenance and repair. Last inspection dated February 4, 2022. A.8 Control of Odorous Emissions. In compliance. I did not detect any dust or odors before entering the facility property and during the inspection. 4) Reporting requirements: There are no reporting requirements in this permit. 5) Compliance History Review: There have been no violations at this facility since permit issuance in December 2014. 6) Stack Test Review: There is no stack test requirement. 7) 112R Status: Based on the facility's inventory, it was decided that they are not subject to 112R reporting requirements. Caldwell Cabinets of NC, LLC Page 4 8) Compliance Assistance and Recommendation: We discussed their upcoming permit renewal. Later, I emailed the facility the small business assistance link. No recommendations were discussed during the inspection. 8) Conclusion/Compliance Statement: Based on review of records and visual observations, this facility appeared to be operating in compliance with the Air Quality standards and regulations at the time of this inspection.