HomeMy WebLinkAboutAQ_F_1300038_20221020_CMPL_InspRpt NORTH CAROLINA DIVISION OF Mooresville Regional Office AIR QUALITY Martin Marietta Materials,Inc.-Rocky River Quarry Inspection Report NC Facility ID 1300038 Date: 10/20/2022 County/FIPS: Cabarrus/025 Facility Data Permit Data Martin Marietta Materials,Inc.-Rocky River Quarry Permit 05615/R13 430 Running Brook Road Issued 7/13/2018 Midland,NC 28107 Expires 6/30/2026 Lat: 35d 16.9630m Long: 80d 34.1730m Class/Status Small SIC: 1423/Crushed And Broken Granite Permit Status Active NAICS: 212313/Crushed and Broken Granite Mining and Quarrying Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP Jay Nivens Ron Kopplin Jay Nivens NSPS: Subpart 000 Manager Environmental President-East Division Manager Environmental Engineering (919)510-4777 Engineering (704)409-1475 (704)409-1475 Compliance Data Comments: Inspection Date 10/20/2022 Inspector's Name Donna Cook Inspector's Signature: D04tna e040A D w Operating Status Operating Compliance Status Compliance-inspection Action Code FCE Date of Signature: 10/20/2022 Inspection Result Compliance Total Actual emissions in TONS/YEAR: TSP S02 NOX VOC CO PM10 *HAP 2017 --- --- --- 2012 --- --- --- *--- Highest HAP Emitted in ounds Five Year Violation History:None Date Letter Type Rule Violated Violation Resolution Date Performed Stack Tests since last FCE: None Date Test Results Test Method(s) Source(s)Tested Martin Marietta Materials,Inc.—Rocky River Quarry October 20, 2022 Page 2 Type Action: X Full Compliance _Partial Compliance _Complaint Other: Evaluation Evaluation/Reinspection Investigation Data Tracking: X Date submitted for initial review 10/20/2022 _IBEAM WARNING/OB,NOD,NOV,NRE X IBEAM Document X IBEAM Inspection,list date inspected X IBEAM LAT/LONG,Facility Locked X IBEAM Inspection, list date draft is submitted X IBEAM LAT/LONG,Coordinates checked X IBEAM Inspection,pollutants/programs checked _IBEAM Complaint X IBEAM Planning,Next Inspection Date 10/01/2024 Directions: From Mooresville Regional Office to Midland, travel Highway 3 South; turn right onto Odell School Road; turn right at the stop light onto Poplar Tent Road due to the no left turn; make a U turn at the next stop light heading east on Poplar Tent Road; turn right on Highway 601/29 (referred to as the Concord Parkway); turn left on Highway 601 Bypass (Warren C. Coleman Boulevard); at the first. stop light past Mary Frances Wall Center School turn right onto Flowes Store Road; and approximately 6 '/2 miles turn left onto Running Brook Road (see entrance sign to Martin Marietta). Martin Marietta Materials,Inc.,Rocky River Quarry, is located 0.2 miles on the right at the address of 430 Running Brook Road. Safety Equipment: This company requires that the inspector watch a video on safety procedures at Martin Marietta Materials,Inc. before the air quality inspection can be conducted. This company requires a hard hat, safety vest, steel-toed shoes, ear protection and safety glasses be worn by the inspector at the quarry. Safety Issues: The inspector should be cautious of conveying and crushing equipment, heavy equipment and truck traffic. Lat/Long Coordinates: A review of the "Facilities Regulated by Air Quality" on the DAQ web site indicates the facility's location is accurate and matches the facility's latitude and longitude coordinates listed in IBEAM. No changes to the latitude and longitude coordinates of this facility are needed in IBEAM. The latitude and longitude coordinates of this facility are locked in IBEAM. Email Contacts: The email addresses for the facility,authorized and technical contacts were verified by Mr. Jay Nivens, manager environmental engineering, during a telephone conversation. No changes to the email contacts are needed in IBEAM. 1. General Information: The purpose of this site visit was to conduct a routine air quality inspection. An air quality permit was issued to this company for the construction and operation of stationary and portable crushing, screening and conveying equipment at the Rocky River quarry site. I phoned Mr. Jay Nivens, manager environmental engineering at(704)409-1475 to discuss the operational status of this facility. Mr.Nivens stated that there is no equipment currently at the quarry site and selling of stockpiled granite rock materials to various customers ceased at this quarry site in 2011 due to the lack of demand for this product. Mr.Nivens stated that Martin Marietta Materials, Inc. has no plans at this time to reopen this quarry site. Martin Marietta Materials, Inc. —Rocky River Quarry October 20, 2022 Page 3 2. Facility Contact Information: During the inspection, I verified the facility contact information in IBEAM with Mr. Nivens during a telephone conversation. No changes to the facility contacts are needed in IBEAM. 3. Compliance history file review: No problems have been noted in the last five years by DAQ prior to this inspection. The current compliance status is discussed in the following sections. 4. Observations of permitted air emission sources and control devices: On July 13, 2018, this office issued Air Permit No. 05615R13 to this company for the construction and operation of the crushing, screening and conveying equipment at this facility. 1: Emission Emission Source Control Control System Source ID Description System ID j Description lNon-metallic mineral processing plant utilizing water suppression with no other control j devices,including: ES-Crush(NSPS) crushing operations N/A N/A ES-Screen(NSPS) screening operations I N/A j N/A ES-Convey(NSPS) conveying operations I N/A j N/A FObserved. Per a telephone conversation with Mr.Nivens,there is no stationary or portable shing, screening or conveying equipment at this quarry site. During the inspection on October 2022, I observed that the gate to this quarry site was locked, and no one was present. 5. Observations of insignificant air emission sources and control devices listed on the current permit: a. None. 6. Observations of air emission sources and control devices not listed on the current permit: a. None. 7. Compliance with specific permit conditions and limitations: This company has no stationary or portable crushing screening or conveying equipment at this quarry site. The stock-piled granite rock materials are located at this quarry site and could be sold to various customers. However,this facility is not operating due to the lack of demand for granite rock materials. Compliance with the specific permit conditions and limitations will be determined once the facility is operational. 8. NSPS/NESHAP Review: EPA has not developed any NESHAP requirements for nonmetallic mineral processing plants. This facility is subject to 40 CFR Part 60, NSPS, Subpart 000 for stationary and portable crushing, conveying and screening nonmetallic mineral processing plants. Currently, this Martin Marietta Materials,Inc.—Rocky River Quarry October 20,2022 Page 4 company has no stationary or portable crushing, screening or conveying equipment at this quarry . site. This facility has stock-piled granite rock materials on-site that could be sold to various customers. However, this facility is currently closed due to the lack of demand for the granite rock materials. This company has no boilers, emergency generators, peak shaving generators, fire pump engines or gasoline storage tanks at this facility. 9. Summary of changes needed to the current permit: None. 10. Compliance assistance offered during the inspection: None. 11. Section 112(r) gpi2licability: This facility does not appear to be subject to the requirements of the Chemical Accident Release Prevention Program, Section 112(r) of the Clean Air Act. 12. Compliance determination: The quarry site is temporarily inactive as indicated by Mr. Nivens during a telephone conversation. No stationary or portable crushing, screening and conveying equipment is located at this quarry site. The compliance status of this facility will be determined when the air emission sources are operational at this quarry site. However, various portable crushing, screening and conveying equipment has operated in past years at this quarry site and-was in compliance with the applicable air quality regulations at the time of the previous inspections. DLC: c: Laserfiche https://ncconnect.sharepoint.com/sites/DAQ-MRO/Counties/CABARRUS/00038/INSPECT 20221020.doex