HomeMy WebLinkAboutAQ_F_1600005_20191204_CMPL_InspRpt NORTH CAROLINA DIVISION OF Wilmington Regional Office
AIR QUALITY Atlantic Veneer Corporation
NC Facility ID 1600005
Inspection Report County/FIPS:Carteret/031
Date: 12/04/2019
Facility Data Permit Data
Atlantic Veneer Corporation Permit n/a
2457 Lennoxville Road Issued n/a
Beaufort,NC 28516 Expires n/a
Lat: 34d 42.5710m Long: 76d 37.7250m Class/Status Permit Exempt
SIC: 2435/Hardwood Veneer And Plywood Permit Status Inactive
NAICS: 321211 /Hardwood Veneer and Plywood Manufacturing Current Permit Application(s)None
Contact Data Program Applicability
Facility Contact Authorized Contact Technical Contact SJP
Scott Van der Werf Michael Kraszeski Scott Vander Werf MACT Part Subpart 6J
Plant Engineer President Plant Engineer NSPS: Subpart
Dc
(252)723-9224 (252)223-8002 (252)723-9224
Compliance Data
Comments:
Inspection Date 12/03/2019
Inspector's Name Tony Sabetti
Inspector's Signature: / Operating Status Operating
Compliance Code Compliance-inspection
Action Code FCE
G3 On-Site Inspection Result Compliance
Date of Signature: A7 141
r2 La /9
Total Actual emissions in TONS/YEAR:
TSP S02 NOX VOC CO PM10 *HAP
2015 26.91 1.88 11.99 2.22 32.33 20.35 2045.28
2010 21.06 4.43 7.22 1.79 11.04 9.47 1067.19
*Highest HAP Emitted inpounds)
Five Year Violation History:
Date Letter Tvoe Rule Violated Violation Resolution Date
08/09/2017 NOV 213.1904 Air Curtain Burners 07/25/2017
01/24/2017 NOV Part 63 -NESHAP/GACT Subpart JJJJJJ Industrial, 03/16/2017
Commercial and Institutional Boilers at Area Sources
10/29/2015 NOV Part 63 -NESHAP/GACT Subpart JJJJJJ Industrial, 12/08/2015
Commercial and Institutional Boilers at Area Sources
Performed Stack Tests since last FCE:None
Date Test Results Test Method(s) Source(s)Tested
Compliance Inspection
Contact for the inspection was made with Scott Van der Werf,plant engineer. The facility was
operating during the inspection. Personnel should wear safety shoes, safety glasses, head protection
(hard-hat),and hearing protection(ear plugs) during inspections.
Compliance History
Atlantic Veneer Corporation has had three NOVs during the past 5 years. October 29, 2015 for not
performing a tune up on boiler 1. Failure to conduct biannual tune ups for ES-Boiler 2 and 3 were
not done within 25 months of the previous tune ups,a NOV dated 1/24/17 was issued. NOV dated
8/9/17 for operating an unauthorized air curtain burner to open burn wood waste.
Plant Description
Atlantic Veneer Corporation receives hardwood veneers. Veneers are clipped horizontally and
vertically. Waste is conveyed to a waste hog then blown through cyclone CD-5 and loaded into a
trailer.
Air Emission Sources
Atlantic Veneer Corporation is operating the air emissions sources and air cleaning devices below:
ES-5 one clipper line CD-5 one simple cyclone (72 inches in
diameter CD-5
Applicable DAQ Rules Atlantic Veneer Corporation shall comply with applicable Environmental
Management Commission Regulations, including Title 15A North Carolina Administrative Code
(NCAC), Subchapter 2D .0202, .0512, .0515, .0521, .0535, .0540 and 2D .0611.
15A NCAC 2D .0202,"Registration of Air Pollution Sources" -Atlantic Veneer Corporation is
registered and exempt from permitting effective July 30,2019.
15A NCAC 2D .0512 "Particulates from Wood Products Finishing Plants," Atlantic Veneer
Corporation is properly operating adequate duct work and collection devices on all particulate
emitting sources and all collection devices are registered and approved by the Commission.
15A NCAC 2D.0515, "Particulates from Miscellaneous Industrial Processes" Particulate
matter emissions from emission source ES-5 is controlled by approved collection device CD-5.
15A NCAC 2D .0521,"Control of Visible Emissions" Visible emissions were evaluated to be
zero percent at the cyclone vent and 10 percent opacity at the discharge vent into the trailer. Scott
stated that Atlantic Veneer are going to install a door on the trailer to better control the wood chip
collection.
15A NCAC 2D .0535,"Excess Emissions Reporting and Malfunctions",No reported excess
emissions during the compliance period.
15A NCAC 2D .0540 "Particulates from Fugitive Dust Emission Sources," No substantive
complaints have been received during the compliance period and no fugitive emission were
observed beyond the property line.
15A NCAC 2D .0611, "Monitoring Emissions from other Sources"
Cyclone Requirements-Inspection and maintenance requirements were verified during the
compliance inspection. Electronic log book records were reviewed during the inspection. Cyclone
CD-8 was last inspected on 12/2/2019.
Inspection Summary
From the observed information, recommend accept this facility as operating in compliance with
applicable EMC Air Quality Regulations at this time.