HomeMy WebLinkAboutAQ_F_0400060_20170629_CMPL_InspRpt NORTH CAROLINA DIVISION OF Fayetteville Regional Office AIR QUALITY NC Biogas, LLC NC Facility ID 0400060 Inspection Report County/FIPS:Anson/007 Date: 07/03/2017 Facility Data Permit Data NC Biogas,LLC Permit 10515/R00 2916 Stanback Ferry Road Issued 12/1/2016 Wadesboro,NC 28170 Expires 11/30/2024 Lat: 34d 58.7498m Long: 80d 1.9002m Classification Synthetic Minor SIC: 4931 /Elec&Other Services Combined Permit Status Active NAICS: 221119/Other Electric Power Generation Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP MACT Part 63: Subpart ZZZZ Anwar Shareef Anwar Shareef Anwar Shareef NSPS: Subpart IIII,Subpart JJJ7 Managing Member Managing Member Managing Member (919)882-3901 (919)882-3901 (919) 882-3901 Compliance Data Comments: Inspection Date 06/29/2017 Inspector's Name Joshua L.Harris Inspector's Signature: �— Operating Status Operating Compliance Code Compliance-inspection Action Code FCE Date of Signature: On-Site Inspection Result Compliance Total Actual emissions in TONS/YEAR: TSP S02 NOX VOC CO PM10 *HAP No emissions inventory on record.The emissions inventory is due 09/01/2024. * Highest HAP Emitted inpounds) Five Year Violation History:None Date Letter Type Rule Violated Violation Resolution Date Performed Stack Tests since last FCE: None Date Test Results Test Method(s) Source(s)Tested I. DIItECTIONS TO SITE: From FRO,take US 401 South through Wagram. South of Wagram,take Old Wire Road(NC 144)to US74. Follow US 74 west toward Wadesboro for—31 miles,then turn right onto Firetower Rd. Follow Firetower Rd. for—1 mile;turn left onto Wall St.then right onto Stanback Ferry Rd. Follow Stanback Ferry Rd. to the"Tee" intersection,and turn left to stay on Stanback Ferry Rd. The facility entrance is on the left—1/4 mile away. H. SAFETY: Standard FRO safety gear. M. FACILITY DESCRIPTION: NC Biogas, LLC is a proposed greenfield poultry manure to energy facility located in Wadesboro,Anson County. Anaerobic digesters will generate biogas using poultry manure received from local farms as a feedstock. The biogas,consisting primarily of methane, carbon dioxide,and hydrogen sulfide, will be passed through two biofilters and an activated carbon filter to reduce H2S to less than 10 ppm before being combusted in four 2,079 hp spark ignition engines which will drive one 1,550 kW generator each. A 59 mmBtu/hr flare will combust the biogas during emergencies or if the engines are down for maintenance. Each engine's exhaust will be controlled using selective catalytic reduction(SCR), and ammonia slip catalyst,and an oxidation catalyst to reduce NOx, CO,and VOC emissions. Solids from the digester will be removed,extruded into pellets, and dried in a 5.2 TPH belt dryer which will be indirectly heated by the engine exhaust. When the engines are not running,the dryer can be run using direct heat from an 8.8 mmBtu/hr natural gas-fired, low NOx,burner. Before being released to the atmosphere,the emissions from the dryer will pass through a venturi scrubber to remove particulates, a packed bed scrubber using sulfuric acid solution to remove ammonia, and a packed bed scrubber using sodium hydroxide and sodium hypochlorite solutions to remove VOCs and H2S, all operating in series. The scrubbers will also handle room air from the manure receiving building for odor control. The dried pellets will be stored in a three-sided bunker,and sold as fertilizer IV. INSPECTION SUMMARY: On 29 June 2017, I,Joshua Harris, DAQ FRO, arrived at NC Biogas, LLC. Upon arrival,I found the gate to be chained and locked,and there was no apparent activity indicating that construction had begun at the facility. I contacted Anwar Shareef,Managing Member, and Authorized Contact,to inquire as to the status of construction. Mr. Shareef responded on 03 July 2017, stating that construction has not begun and he has been in the process of securing other permits required for the facility. He stated that the goal is to commence construction by the end of this year, and to begin commercial operation sometime in Q3 2018. V. PERMITTED EMISSION SOURCES: *No sources have been constructed* Emission Emission So' ES-ENGI, Four(4)2,079 hp Biogas-fired ES-ENG2, Spark Ignition Internal Four(4)Catalytic emission control units, ES-ENG3, Combustion Engines,utilizing CD-SCRCOI, one(1)per engine,each consisting of a ES-ENG4 CD-SCRCO2, selective catalytic reduction(SCR)system low-sulfur,conditioned digester CD-SCRC03, utilizing urea injection,an ammonia slip (NSPS) gas,in combination with one(1) CD-SCRC04 catalyst,and an oxidation catalyst (NESHAP) 1,550 kW electrical generator (30 cubic feet total catalyst volume each) (SB3 BACT) each Three-stage scrubber system consisting of: 5.2 TPH Belt Dryer heated Venturi Scrubber indirectly utilizing waste heat CD-SCRUB 1 in series with from engine exhaust or directly in series with Packed Bed Scrubber ES-DRYI by a low-NOx natural gas-fired CD-SCRUB2 (utilizing sulfuric acid solution) burner in series with in series with (8.8 mmBtu/hr maximum heat CD-SCRUB3 Packed Bed Scrubber input) (utilizing sodium hydroxide and/or sodium hypochlorite solutions) Biogas-fired enclosed safety flare ES-FLAREI (59 mmBtu/hr maximum heat N/A N/A input) VI. INSIGNIFICANT ACTIVITIES: Source of Souree`of . �N..ce. _..f� ., f u111t•Pu . :. Title V IES-Bunker Pellet Storage Bunker 2Q•0102(h)(5) No Yes IES-EmGen One(1) 100 kW Diesel-fired emergency generator NESHAP Subpart ZZZZ 2Q •0102(h)(5) Yes Yes NSPS Subpart IIII VII. NON-COMPLIANCE HISTORY SINCE 2010: No negative compliance history. VIII. RISK MANAGEMENT(112r): This facility does not store any 112(r)subject materials above threshold limits. Therefore,the facility is not required to maintain a written Risk Management Plan(RMP). IX. CONCLUSION AND RECOMMENDATIONS: NC Biogas,LLC has not yet been constructed. PINK SHEET ADDITIONS: None /j lh