HomeMy WebLinkAboutAQ_F_1100542_20170308_ST_ProtRvw (4) ROY COOPER Governor MICHAEL S. REGAN 11.0 Secretary Air Quality MICHAEL A. ABRACZINSKAS ENVIRONMENTAL QUALITY /Acting Arector March 7, 2017 Kristy Smith Bioreactor Project Manager Buncombe County Landfill H 81 Panther Branch Rd Alexander,NC 29701 Subject: Buncombe County Landfill H Alexander,Buncombe County,NC Facility ID 11-00542,Air Permit No. 10398T01 Nitrogen Oxides, Carbon Monoxide,and Volatile Organic Compounds Emissions Testing of Landfill Gas-Fired Engine/Generator ES-G1 Proposed Test Date: April 4, 2017 DAQ Tracking No. 2017-097ST Dear Ms. Smith: The protocol submittal form(PSF) submitted by GEL Engineering, LLC (GEL)has been reviewed by the N.C. Division of Air Quality(DAQ). The proposed EPA Methods 7E, 10, and 25A emissions testing for generator ES-G1 is acceptable. ES-G1 is a landfill gas-fired engine/generator set with an engine rated at 1966 horsepower(hp)or 17 million Btu per hour(mmBtu/hr)and a generator rated at 1466 kilowatt(kW)output capacity. There are no control devices associated with the generator. 40 CFR 63 Subpart ZZZZ National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines(RICE)requires that the facility comply with emission limits as stated in 40 CFR 60 Subpart JJJJ Standards ofPerformancefor Stationary Spark Ignition Internal Combustion Engines. Permit section 2.1.13.5. also specifies that North Carolina General Statute GS 62-133.8(g)—SB3 BACT limits apply. SB3 BACT defers to Subpart JJJJ for emission limits. Subpart JJJJ and permit section 2.1.B.3.b. specifies the following emission limits: • CO: 5.0 g/hp-hour or 610 ppmvd at 15%02 • NO.: 2.0 g/hp-hour or 150 ppmvd at 15%02 • VOCS: 1.0 b/hp-hour or 80 ppmvd at 15%02 GEL proposed EPA Method 10 for CO, Method 7E for NO, and Method 25A for VOCs. EPA Method 25A will be used with a methane cutter. The proposed methods are acceptable for testing. State of North Carolina i Environmental Quality I Air Quality 217 W.Jones Street 11641 Mail Service Center I Raleigh,North Carolina 27699-1641 919 707 8400 Kristy Smith March 7,2017 Page 2 Approval of the proposed methods does not exempt the tester, in anyway, from the minimum requirements of the applicable test methods. Any deviations from the applicable methodologies remains subject to the approval of the Division of Air Quality. If you have any questions concerning this review, please contact me at Brent.Hall(d-nedenngov or(919)707-8427. Sincerely, Brent W. Hall Environmental Engineer N.C.Division of Air Quality,NCDEQ Cc: Brendan Davey, P.E., ARO Central Files, Buncombe County Kirk Alexander, GEL IBEAM Documents— 1100542