HomeMy WebLinkAboutAQ_F_1000067_20050609_CEM_RptRvwLtr NCDENR
North Carolina Department of Environment and Natural Resources
Division of Air Quality
Michael F. Easley,Governor William G. Ross,Jr.,Secretary
B. Keith Overcash, P.E., Director
June 9, 2005
Mr. Gary Willer
The Plant Manager
Cogentrix of North Carolina,Inc.
P.O. Box 10836
Southport,North Carolina 28461-0836
Subject: Excess Emissions Report(EER)for the 1 st Quarter, 2005
Relative Accuracy Test Audit(RATA)report for NO,and CO., CEMS Analyzers
on Units 1 and 2, 2005
Facility I.D.No. 1000067
Dear Mr. Willer:
The Division of Air Quality(DAQ)has reviewed the subject reports dated April 19 and March 18,
2005 and submitted by Cogentrix of Southport, Inc. for Units No. 1 and 2. The reports were reviewed
for compliance with the applicable emission standards set forth in 40 CFR Part 60 Subpart Db, the
general provisions of 40 CFR 60.11(d) and 40 CFR 60.13,
For Units 1 and 2, compliance with the nitrogen oxide emission standard is determined through the use
of a 30-day rolling average emission rate in accordance with 40 CFR 60.46b. There were no violations
of the NO, emission standard for Units 1 and 2.
Also,Units 1 and 2 are subject to the opacity standards set forth in 40 CFR 60 Subpart Db. Thus, when
reviewed for compliance with the standards, the report indicated 90 minutes(15 periods) of opacity
excursions for Unit 1 and 186 minutes (31 periods)of opacity excursions for Unit 2. The six-minute
opacity excess emission incidents for Unit 1 occurred due to broken bags and shutdown. The six-
minute opacity excess emission incidents for Unit 2 occurred due to broken bags, loss of pulse air, and
shutdown
DAQ's review of the Continuous Emissions Monitoring Compliance Report(CEMCR)for NO,., the
Excess Emissions Report(EER) for opacity, and Continuous Monitoring System(CMS)downtime
(DT) for Units 1 and 2 during the quarter ending March 31, 2005 confirmed the reported results as
follows:
Units: No. 1 No. 2
NOX Excess Emission: 0.00% 0.00%
NO,CMS Downtime: 0.12% 0.13%
Opacity Excess Emission: 0.09% 0.19%
Opacity CMS Downtime: 0.10% 0.19%
Technical Services Section
1641 Mail Service Center,Raleigh,North Carolina 27699-1641 One
2728 Capital Blvd.,Raleigh, North Carolina 27604 NorthCarohna
Phone: 91 9-733-1 728 1 FAX 919-733-18121 Internet: www.ncair.org ;Vaturallff
An Equal OpportunitylAffirmative Action Employer-50% Recycled110% Post Consumer Paper
Mr. Gary E. Willer
June 9, 2005
For the purpose of assessing good operation and maintenance(O&M)practices for particulate emission
control devices and all continuous monitoring systems, the DAQ uses, among other things, the EPA
Region IV CEM Enforcement Plan (CEP). Based on this plan, excess emissions(opacity only)and/or
monitor downtime(all CMS) greater than 2%, 5%for two consecutive quarters or 10% for any one
quarter is followed by appropriate agency response and for enforcement purposes only. All data in your
first quarter report indicated you were below the CEP threshold levels for all of your Units 1 and 2.
The CEM RATA report was reviewed and the NO,, and COZ CEMs monitors on Units 1 and 2 appear
to have been tested in accordance with 40 CFR 60, Appendix B, Perfonnance Specifications 2 and 3
and therefore acceptable. The model/serial numbers and relative accuracy values are as follows:
Source Parameter Monitored Model and Serial No. % Relative Accuracy
Unit 1 NOx TEI 42C-71812-369 2.7%of RM
Unit 2 NOx TEI 42C-71830-369 7.7%of RM
The next relative accuracy test for Unit 1 is due by March 31, 2006.
Finally, unless the pen-nit or any applicable rule states otherwise,your future quarterly Continuous
Emission Monitoring Compliance Report and Excess Emission Reports will be reviewed consistent
with the compliance of the emission control standards set forth in 40 CFR 60, Subpart Db, and the CEP
will be used to assess excess opacity emissions and CMS downtime. All violations of the NO,emission
standard may result in enforcement actions.
If you have any questions regarding the issues discussed in this letter,please contact me at
(919)715-0726.
Sincerely,
Richard R. Simpson
Environmental Engineer
cc: _� ike Aldridge
Wayne Cook-WIRO
Central File-Brunswick Co.
Tracy Patterson—Cogentrix
IMPAQ—Documents — 1000067 (Filename : SimpsonRR\Cogentrix\2005\cgEER1Q05sp.doc)