HomeMy WebLinkAboutAQ_F_0000075_20130725_PRMT_Permit NCER
North Carolina Department of Environment and Natural Resources
Division of Air Quality
Pat McCrory Sheila C. Holman John E. Skvarla, III
Governor Director Secretary
July 25,2013
Mr. Walter L. Hillis III
Sr. Environmental Engineer
Ralph Rogers and Company
250 Union Valley Road
Oak Ridge, TN 37830
Subject: Air Permit No. 09935R05
Ralph Rogers and Company - Burnsville Plant
Yancey County,North Carolina
Permit Class:Synthetic Minor
Facility ID# 0000075
Dear Mr. Hillis:
In accordance with your completed application received May 30, 2013, we are forwarding
herewith Permit No. 09935R05 to Ralph Rogers and Company - Burnsville Plant, Yancey County,
North Carolina for the construction and operation of air emissions sources or air cleaning devices
and appurtenances. Additionally, any emissions activities determined from your air permit
application as meeting the exemption requirements contained in 15A NCAC 2Q .0102 have been
listed for information purposes as an "ATTACHMENT" to the enclosed air permit. Please note the
records retention requirements are contained in General Condition 2 of the General Conditions and
Limitations.
If any parts,requirements, or limitations contained in this permit are unacceptable to you,
you have the right to request a formal adjudicatory hearing within 30 days following receipt of this
permit, identifying the specific issues to be contested. Such a request will stay the effectiveness of
the entire permit. This hearing request must be in the form of a written petition, conforming to G.S.
150B-23 of the North Carolina General Statutes, and filed with the Office of Administrative
Hearings, 6714 Mail Service Center, Raleigh,NC 27699-6714. The form for requesting a formal
adjudicatory hearing may be obtained upon request from the Office of Administrative Hearings.
Unless a request for a hearing is made pursuant to G.S. 15013-23,this air permit shall be final and
binding.
. You may request modification of your air permit through informal means pursuant to G.S.
15013-22. This request must be submitted in writing to the Director and must identify the specific
Asheville Regional Office-Division of Air Quality
2090 U.S.Highway 70,Swannanoa,North Carolina 28778
Phone:828-296-4500/FAX:828-299-7043
Internet:www.ncair,orq
An Equal Opportunity\Affirmative Action Employer-Made in part by Recycled Paper
Mr. Walter L. Hillis III
July 25, 2013
Page 2
provisions or issues for which the modification is sought. Please-note that the permit will become
final and binding regardless of a request for informal modification unless a request for a hearing is
also made under G.S. 15013-23.
Unless exempted by a condition of this permit or the regulations, construction of new
air pollution sources or air cleaning devices, or modifications to the sources or air cleaning
devices described in this permit must be covered under a permit issued by the Division of Air
Quality prior to construction. Failure to do so is a violation of G.S. 143-215.108 and may
subject the Permittee to civil or criminal penalties as described in G.S. 143-215.114A and 143-
215.114B.
This permit shall be effective from July 25, 2013 until June 30, 2018, is nontransferable to
future owners and operators, and shall be subject to the conditions and limitations as specified
therein.
Changes have been made to the permit stipulations. The Permittee is responsible for
carefully reading the entire permit and evaluating the requirements of each permit
stipulation. The Permittee shall comply with all terms, conditions, requirements, limitations
and restrictions set forth in this permit. Noncompliance with any permit condition is grounds
for enforcement action, for permit termination, revocation and reissuance, or modification, or
for denial of a permit renewal application. Specific changes and additions are summarized
below (note: this list may not include all changes and additions):
* Stack testing to determine compliance with 2D .0506 (Particulates from Hot Mix
Asphalt Plants) and 2D .0524 (NSPS, Subpart I) is added to the permit with this
renewal. Results from testing are due by June 30, 2017. If the facility initiates
combustion of recycled No. 2 or recycled No. 4 fuel oil,written notification is required
within 30 days and results from testing while burning recycled No. 2 or recycled No. 4
fuel oil are due within 90 days.
• The RAP system is removed from the equipment list. The Division has concluded that
this type of equipment is no longer required to be listed in the permit.
• This Permit contains an emissions inventory requirement for the 2017 calendar year as
part of the next renewal in 2018.
Should you have any questions concerning this matter,please contact Christopher Scott at(828)
296-4500.
Sincerely,
'A't- 4.
Paul K. Muller, P.E.
Regional Air Quality Supervisor
PKM:ces
Enclosures
c: Asheville Regional Office
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF AIR QUALITY
AIR PERMIT NO. 09935R05
Issue Date: July 25,2013 Effective Date: July 25, 2013
Expiration Date: June 30, 2018 Replaces Permit: 09935R04
To construct and operate air emission source(s) and/or air cleaning device(s), and for the
discharge of the associated air contaminants into the atmosphere in accordance with the provisions
of Article 21B of Chapter 143, General Statutes of North Carolina(NCGS) as amended, and other
applicable Laws, Rules and Regulations,
Ralph Rogers and Company - Burnsville Plant
421 OMC Drive
Burnsville, Yancey County, North Carolina
Permit Class: Synthetic Minor
Facility ID# 0000075
(the Permittee) is hereby authorized to construct and operate the air emissions sources and/or air
cleaning devices and appurtenances described below:
Emission Emission Source Control # Control System
Source ID Description System ID Description
_ _ P __. .... .. . ._
one drum-mix asphalt plant(300 tons per hour maximum capacity), consisting of:
ES-01 one natural gas/virgin No. CD-1 'one bagfilter
(NSPS) 2/recycled No. 2/virgin No. (10,374 square feet of filter area)
4/recycled No. 4 fuel oil-fired drum'
mix asphalt plant (105 million Btu
per hour maximum heat input rate) ' f
ES-02, ES-03`three 150-ton asphalt storage silos
and ES-04
(NSPS)
N/A j N/A
FUG1 one silo filling operation and one N/A N/A
(NSPS) 11truck loadout operation
ES-10 one fines silo CD-2 one bagfilter
(NSPS) ( (176 square feet of filter area)
CD-1 in series with one bagfilter
(10,374 square feet of filter area)
Permit No. 09935R05
Page 2
Emission p Emission Source Control Control System
Source ID Description System ID I Description
..............
IlPost-consumer Reclaimed Asphalt Shingles (PRAS) processing system consisting of:
!F_9S-_08 oneaPRAS loading bin (20-ton
N/A N/A
capacity)
................. .........................................
ES-09 11one PRAS conveyor(250 ton per N/A 1 N/A
hour maximum process rate)
in accordance with the completed application 0000075.13B received May 30,2013 including any
plans, specifications,previous applications, and other supporting data, all of which are filed with the
Department of Environment and Natural Resources, Division of Air Quality(DAQ)and are
incorporated as part of this permit.
This permit is subject to the following specified conditions and limitations including any
TESTING,REPORTING, OR MONITORING REQUIREMENTS:
A. SPECIFIC CONDITIONS AND LIMITATIONS
1. Any air emission sources or control devices authorized to construct and operate above must
be operated and maintained in accordance with the provisions contained herein. The
Permittee shall comply with applicable Environmental Management Commission
Regulations, including Title 15A North Carolina Administrative Code (NCAC), Subchapter
2D .0202,2D .0506,2D .0516,2D .0521,2D .0524 (40 CFR 60, Subpart 1), 2D .0535,2D
.0540, 2D .0605, 2D .0611,2D .1100, 2D .1806,2Q .0315, 2Q .0317 (Avoidance) and 2Q
.0711.
2. PERMIT RENEWAL AND EMISSION INVENTORY REQUIREMENT -The Permittee,
at least 90 days prior to the expiration date of this permit, shall request permit renewal by
letter in accordance with 15A NCAC 2Q .0304(d) and(f). Pursuant to 15A NCAC 2Q
.0203(i), no permit application fee is required for renewal of an existing air permit (without
a modification request). The renewal request (with AA application form) should be
submitted to the Regional Supervisor,DAQ. Also, at least 90 days prior to the expiration
date of this permit,the Permittee shall submit the air pollution emission inventory report
(with Certification Sheet) in accordance with 15A NCAC 2D .0202,pursuant to N.C.
General Statute 143 215.65. The report shall be submitted to the Regional Supervisor, DAQ
and shall document air pollutants emitted for the 2017 calendar year.
3. PARTICULATE CONTROL REQUIREMENT- As required by 15A NCAC 2D .0506
"Particulates from Hot Mix Asphalt Plants,"
a. Particulate matter emissions resulting from the operation of a hot mix asphalt plant
shall not exceed allowable emission rates. The allowable emission rates are, as
defined in 15A NCAC 2D .0506, a function of the process weight rate and shall be
determined by the following equation(calculated to three significant figures), where
P is.the process throughput rate in tons per hour(tons/hr) and E is the allowable
emission rate in pounds per hour(lbs/hr).
Permit No. 09935R05
Page 3
E=4.9445 * (P) 0.4376 for P <300 tons/hr, or
E =60 lbs/hr for P>=300 tons/hr
b. Visible emissions from stacks or vents at a hot mix asphalt plant shall be less than 20
percent opacity when averaged over a six-minute period.
c. Fugitive dust emissions shall be controlled as required by 15A NCAC 2D .0540
"Particulates From Fugitive Dust Emission Sources."
d. Fugitive emissions for sources at a hot mix asphalt plant not covered elsewhere
under this Rule shall not exceed 20 percent opacity averaged over six minutes.
4. SULFUR DIOXIDE CONTROL REQUIREMENT -As required by 15A NCAC 2D .0516
"Sulfur Dioxide Emissions from Combustion Sources," sulfur dioxide emissions from the
drum mix asphalt plant(ID No. ES-01) shall not exceed 2.3 pounds per million Btu heat
input.
5. VISIBLE EMISSIONS CONTROL REQUIREMENT -As required by 15A NCAC 2D
.0521 "Control of Visible Emissions," visible emissions from the PRAS loading bin(ID No.
ES-08) and the PRAS conveyor(ID No. ES-09), manufactured after July 1, 1971, shall not
be more than 20 percent opacity when averaged over a six-minute period, except that six-
minute periods averaging not more than 87 percent opacity may occur not more than once in
any hour nor more than four times in any 24-hour period. However, sources which must
comply with 15A NCAC 2D .0524 "New Source Performance Standards" or .1110
"National Emission Standards for Hazardous Air Pollutants" must comply with applicable
visible emissions requirements contained therein.
6. 15A NCAC 2D .0524 "NEW SOURCE PERFORMANCE STANDARDS" - For the drum
mix asphalt plant(ID No. ES-01), three storage silos (ID Nos. ES-02, ES-03 and ES-04), the
fines silo (ID No. ES-10) and the silo filling and truck loadout operation (ID No. FUG1), the
Permittee shall comply with all applicable provisions, including the notification, testing,
reporting, recordkeeping, and monitoring requirements contained in Environmental
Management Commission Standard 15A NCAC 2D .0524 "New Source Performance
Standards" (NSPS) as promulgated in 40 CFR 60, Subpart I, including Subpart A "General
Provisions."
a. NSPS Emissions Limitations - As required by 15A NCAC 2D .0524, the Permittee
shall not discharge or cause the discharge into the atmosphere from any affected
source any gases which:
i. Contain particulate matter in excess of 90 mg/dscm(0.04 gr/dscf); or
ii. Exhibit 20 percent opacity, or greater.
7. NOTIFICATION REQUIREMENT - As required by 15A NCAC 2D .0535,the Permittee of
a source of excess emissions that last for more than four hours and that results from a
malfunction, a breakdown of process or control equipment or any other abnormal
conditions, shall:
Permit No. 09935R05
Page 4
a. Notify the Director or his designee of any such occurrence by 9:00 a.m. Eastern time
of the Division's next business day of becoming aware of the occurrence and
describe:
i. the name and location of the facility,
ii. the nature and cause of the malfunction or breakdown,
iii. the time when the malfunction or breakdown is first observed,
iv. the expected duration, and
V. an estimated rate of emissions.
b. Notify the Director or his designee immediately when the corrective measures have
been accomplished.
This reporting requirement does not allow the operation of the facility in excess of
Environmental Management Commission Regulations.
8. FUGITIVE DUST CONTROL REQUIREMENT -As required by 15A NCAC 2D .0540
"Particulates from Fugitive Dust Emission Sources," the Permittee shall not cause or allow
fugitive dust emissions to cause or contribute to substantive complaints or excess visible
emissions beyond the property boundary. If substantive complaints or excessive fugitive
dust emissions from the facility are observed beyond the property boundaries for six minutes
in any one hour(using Reference Method 22 in 40 CFR, Appendix A), the owner or
operator may be required to submit a fugitive dust plan as described in 2D .0540(f).
"Fugitive dust emissions" means particulate matter that does not pass through a process
stack or vent and that is generated within plant property boundaries from activities such as:
unloading and loading areas,process areas stockpiles, stock pile working,plant parking lots,
and plant roads (including access roads and haul roads).
9. TESTING REQUIREMENT-Under the provisions of North Carolina General Statute 143-
215.108 and in accordance with 15A NCAC 2D .0605, the Permittee shall demonstrate
compliance with the emission limit(s) by testing the emission source(s) for the specified
pollutant(s) as follows:
t .
Affected Source(s) Pollutant Emission Limit Test Method
Filterable rN
D .0506 and f
one drum dryer/mixer, and Particulate MatterS Subpart I Method 5
associated material handling Condensable per 2D .0506 FMethod 202
equipment(ID No. ES-1) Particulate Matter;
Visible Emissions 20% opacity Method 9 I
_p Y.
a. At least 45 days prior to performing any required emissions testing, the Permittee
must submit a testing protocol to the Regional Supervisor, DAQ for review and
approval. All testing protocols must be approved by the DAQ prior to performing
such tests.
Permit No. 09935R05
Page 5
b. To afford the Regional Supervisor, DAQ, the opportunity to have an observer
present, the Permittee shall PROVIDE the Regional Office, in WRITING, at least 15
days notice of any required performance test(s).
c. Two copies of the test results must be submitted to the Regional Supervisor, DAQ, in
accordance with the approved procedures of the Environmental Management
Commission by June 30, 2017. If this performance test is not conducted using
recycled No. 2 or recycled No. 4 fuel oil, an additional test shall be conducted
using recycled No. 2 or recycled No. 4 fuel oil within 90 days of startup on
recycled No. 2 or recycled No. 4 fuel oil.
d. This permit may be revoked,with proper notice to the Permittee, or enforcement
procedures initiated, if the results of the test(s) indicate that the facility does not meet
applicable limitations.
e. The source shall be responsible for ensuring, within the limits of practicality, that the
equipment or process being tested is operated at or near its maximum normal
production rate, or at a lesser rate if specified by the Director or his delegate.
f. All associated testing costs are the responsibility of the Permittee.
10. FABRIC FILTER REQUIREMENTS includingcartridge artridge filters, baghouses, and other dry
filter particulate collection devices -As required by 15A NCAC 2D .0611, particulate matter
emissions shall be controlled as described in the permitted equipment list.
a. Inspection and Maintenance Requirements - To comply with the provisions of this
permit and ensure that emissions do not exceed the regulatory limits, the Permittee
shall perform, at a minimum, an annual (for each 12 month period following the
initial inspection) internal inspection of each bagfilter system. In addition, the
Permittee shall perform periodic inspections and maintenance as recommended by
the equipment manufacturer.
b. Recordkeeping Requirements - The results of all inspections and any variance from
manufacturer's recommendations or from those given in this permit (when
applicable) shall be investigated with corrections made and dates of actions recorded
in a logbook. Records of all maintenance activities shall be recorded in the logbook.
The logbook (in written or electronic format) shall be kept on-site and made
available to DAQ personnel upon request.
11. TOXIC AIR POLLUTANT EMISSIONS LIMITATION AND REPORTING
REQUIREMENT- Pursuant to 15A NCAC 2D .1100 "Control of Toxic Air Pollutants," and
in accordance with the approved application for an air toxic compliance demonstration, the
following permit limits shall not be exceeded:
Permit No. 0993 5RO5
Page 6
............................... ......................
' Emission Limit'
Affected Source(s) Toxic Air Pollutant
........... ..........
..............
Arsenic & Compounds
0.016 lb/yr
Arsenic
(7778394))
................
Benzene (71-43-2) 11.19 lb/yr
one drum mix asphalt plant aggregate ';IFormaldehyde (50-00-0) 0.930 lb/hr I
dryer(ID No. E S-1) Mercury, vapor
i 0 0 19 lb/day
(Component of HGC) (7439-97-6),
..................
Vickel metal(C 0.45 lb/day
omponent of NIC) (7440- 2
.......... 0 -0..........
Benzene (71-43-2)
�F 0.11 lb/yr
three 150-ton asphalt storage silos
Formaldehyde (50-00-0) 02521
'(ID Nos. ES-2,ES-3, and ES-4) 0. b/hr
................. . ........... .............- . ..... .. ..............
0.062 lb/yr
nz
;F
one silo filling operation and one truck e ene (71-43-2 ..........
loadout operation(ID No. FUG1) Formaldehyde (50-00-0) 0.00 11 lb/hr
a. Restrictions - To ensure compliance with the above limits,the following restrictions
shall apply:
i. the production of hot mix asphalt may not exceed 275,000 tons per 12-month
period or 300 tons per hour
ii. particulate matter emissions shall be controlled by the two bagfilters (ID No.
CD-1 and CD-2)
iii. the facility equipment shall be constructed and operated according to the
parameters set forth in the submitted modeling result approved by DAQ on
July 29, 2008 such that:
A. the height of the main dryer stack(ID No. ES-1) shall not be less than
30 feet(9.14 meters) high;
B. the main dryer stack (ID No. ES-1) shall not be closer than 519 feet
(15 8 meters) from the nearest property boundary;
C. the silo vent(ID No. ES-2) shall not be closer than 594 feet (181
meters) from the nearest property boundary;
D. the silo loadout(ID No. ES-3) shall not be closer than 594 feet (181
meters) from the nearest property boundary; and
E. only one truck shall be loaded with asphalt at any one time.
b. Reporting Requirements - Compliance with this limit shall be established by
compliance with the Synthetic Minor limit,recordkeeping, and reporting
requirements outlined in Specific Condition and Limitation No. 13.
Permit No. 09935R05
Page 7
12. CONTROL AND PROHIBITION OF ODOROUS EMISSIONS -As required by 15A
NCAC 2D .1806 "Control and Prohibition of Odorous Emissions" the Permittee shall not
operate the facility without implementing management practices or installing and operating
odor control equipment sufficient to prevent odorous emissions from the facility from
causing or contributing to objectionable odors beyond the facility's boundary.
13. LIMITATION TO AVOID 15A NCAC 2Q .0501 - Pursuant to 15A NCAC 2Q .0315
"Synthetic Minor Facilities," to avoid the applicability of 15A NCAC 2Q .0501 "Purpose of
Section and Requirement for a Permit," as requested by the Permittee, facility-wide
emissions shall be less than the following:
ollutant Emission Limit
( (Tons per consecutive 12-month period)
S02 —y 100
CO^ 100
a. Operations Restrictions - To ensure emissions do not exceed the limitations above,
the following restrictions shall apply:
i. The amount of asphalt produced shall be less than 275,000 tons per
consecutive 12-month period.
ii. The sulfur content of the No. 2 fuel oil, including recycled No. 2 fuel oil shall
be limited to 0.5% sulfur by weight.
iii. the sulfur content of No. 4 fuel oil, including recycled No. 4 fuel oil, shall be
limited to 2.0%sulfur by weight
iv. If multiple fuels are used, emissions should be determined using the sum of
the individual emissions rates.
b. Fuel Certification Requirement - Fuel supplier certification shall be kept on-site
and made available to DAQ personnel upon request. The Permittee shall keep each
record on file for a minimum of three years.
c. Reporting Requirements - Within 30 days after each calendar year, regardless of
the actual emissions,the Permittee shall submit the following to the Regional
Supervisor, DAQ, in writing:
i. the monthly amount of asphalt produced for each fuel type, and the total
annual amount of asphalt produced for each fuel type, for the previous 12-
month period; and
ii. a copy of the fuel certification for the shipment of each fuel oil type with the
highest sulfur content by weight delivered during the 12-month period. The
fuel supplier certification shall include the following information:
A. the name of the oil supplier; and
Permit No. 09935R05
Page 8
B. a certified statement signed by the owner or operator of the facility
that the records of fuel supplier certification submitted represent all of
the fuel combusted during the reporting period.
14. LIMITATION TO AVOID 15A NCAC 2D .0530 "PREVENTION OF SIGNIFICANT
DETERIORATION" - In accordance with 15A NCAC 2Q .0317, to comply with this permit
and avoid the applicability of 15A NCAC 2D .0530 "Prevention of Significant
Deterioration," as requested by the Permittee, emissions shall be limited as follows:
Emission Limit
Affected Source(s)i Pollutant(Tons Per Consecutive 12-month Period)
one drum mix asphalt plant; SO2 �250
(ID No. ES-1)
Compliance with this limit shall be established by compliance with the Synthetic Minor
limit, recordkeeping, and reporting requirements outlined in Specific Condition and
Limitation No. 13, above.
15. RECYCLED ASPHALT SHINGLE REQUIREMENTS - In accordance with Rule 2Q
.0317, the Permittee is avoiding the applicability of Rule 2Q .0700 and 2D .1100 for
asbestos, and 40 CFR 61, Subpart M,National Emission Standard for Asbestos by using
post-consumer reclaimed asphalt roofing shingles (also known as PRAS and herein denoted
as recycled shingles) which are equivalent to their virgin or unadulterated counterparts. The
Permittee is allowed to use the recycled shingles and associated asphalt roofing materials
provided the following conditions are met:
Specifications - The recycled shingles shall be considered equivalent to unadulterated
asphalt and aggregate for use in manufacturing of asphalt concrete by meeting the following
criteria:
The recycled shingles and roofing materials are certified to be free of asbestos containing
material (ACM). This certification shall be provided by demonstration that the materials
sampled are representative of the recycled asphalt roofing materials and are certified to be
free of ACM as measured by the method specified in appendix E, 40 CFR 763, Section 1,
polarized light microscopy (PLM). Certification shall be provided by NC-accredited
Asbestos Inspectors or Roofing Supervisors to sample the PRAS to meet the above criteria.
Accreditation shall be obtained through the Division of Public Health's Health Hazards
Control Unit.
a. The Permittee is responsible for ensuring that the recycled shingles and roofing
materials, as used at the site,meet the approved criteria for unadulterated materials
including meeting minimum sampling criteria as specified by best practices. These
practices shall include visual inspection of each load for suspect ACM and a
sampling of at least one sample event per 100 tons of recycled shingles received for
processing.
Permit No. 09935R05
Page 9
i. Each load or batch of recycled asphalt roofing materials purchased from or
provided by an outside vendor shall include a certification that the material
does not contain ACM and that it was tested in accordance with the best
practices specified above, or
ii. If certification of the incoming recycled shingle material is not provided at
delivery by an outside vendor, the Permittee shall arrange for testing and
certification of the material as not being ACM, meeting the specifications
outlined above,prior to use in the process. The Permittee shall arrange for the
results of such sampling and testing to be provided in a manner and form
consistent with meeting the recordkeeping requirements cited below.
b. The Permittee is held responsible for any discrepancies discovered by DAQ as a
result of any sampling and analysis of the recycled shingles and asphalt roofing
materials.
c. Recordkeeping Requirements - The Permittee shall maintain certifications that the
materials received and used are not ACM. These certifications shall be maintained at
the facility for a minimum of three years, and shall be made available to
representatives of the DAQ upon request. In addition, accurate records of the
following shall be maintained:
i. The actual amount of recycled shingles delivered to and used at the facility in
the production of asphalt concrete pavement.
ii. Each load or batch of recycled shingles shall include the following:
A. A delivery manifest document clearly showing the shipment content
and amount, its place and date of loading, and place and date of
destination.
B. A batch specific analytical report that contains an analysis for all
constituents/properties listed above in the specification. Analytical
results of the samples representative of the recycled shingles/roofing
materials shipment from the vendor shall be no more than one year
old when received.
C. Batch signature information consisting of the following: a batch
number, batch weight or volume of recycled shingles/roofing
materials delivered.
D. A certification statement indicating that the recycled shingles were
sampled in accordance with best practices and tested according to
appendix E, 40 CFR 763, Section 1 and do not contain ACM or are
otherwise asbestos-free as determined by PLM prior to grinding.
Permit No. 09935R05
Page 10
d. The Permittee shall be obligated to comply with any additional regulations or obtain
any additional permits associated with the receipt and/or storage of the recycled
asphalt roofing materials. This permit condition to use these materials in the asphalt
concrete manufacturing process creates no waiver from other applicable laws and
regulations.
e. The DAQ reserves the right to require additional testing and/or monitoring of the
recycled shingles/roofing materials in accordance with Rule 2Q. 0317.
16. VENDOR SUPPLIED RECYCLED No(s). 2 and 4 FUEL OIL REQUIREMENTS - In
accordance with Rule 2Q .0317,the Permittee is avoiding the applicability of Rule 2Q .0700
by using recycled fuels which are equivalent to their virgin counterparts. The Permittee is
allowed to use the recycled fuel oil(s) supplied by a DAQ-approved vendor as follows:
a. Specifications - The recycled fuel oil(s) shall be equivalent to unadulterated fossil
fuel by meeting the following criteria:
Constituent/Property Allowable Level
Arsenic �1 0 ppm maximum
_.. . . m _.. _ _ . ... . _..
Cadmium 2.0 p=111-11pm maximum_
Chromium 5.0 ppm maximum
Lead 100 ppm maximum
Total Halogens 1000 ppm maximum
Flash Point
No. 2 100°F minimum
No. 4 130T minimum
Sulfur
No. 2 0.5%maximum (by weight);
No. 4 2.0%maximum (by weight);
Ash 1 0%maximum
b. The Permittee is responsible for ensuring that the recycled fuel oil(s), as received at
the site,meet(s)the approved criteria for unadulterated fuel. The Permittee is held
responsible for any discrepancies discovered by DAQ as a result of any sampling and
analysis of the fuel oil(s).
c. Recordkeeping Requirements - The Permittee shall maintain at the facility for a
minimum of three years, and shall make available to representatives of the DAQ
upon request, accurate records of the following:
i. The actual amount of recycled fuel oil(s) delivered to, and combusted at the
facility on an annual basis.
ii. Each load of recycled fuel oil received shall include the following:
Permit No. 09935R05
Page 11
A. A delivery manifest document clearly showing the shipment content
and amount, its place and date of loading, and place and date of
destination.
B. A batch specific analytical report that contains an analysis for all
constituents/properties listed above. Analytical results of the samples
representative of the recycled oil shipment from the vendor shall be
no more than one year old when received.
C. Batch signature information consisting of the following: a batch
number, tank identification with batch volume of recycled oil, date
and time the batch completed treatment, and volume(s) delivered.
D. A certification indicating that the recycled fuel oil does not contain
detectable PCBs (<2ppm).
d. Reporting Requirements- Within 30 days after each calendar year, regardless of the
amount received or combusted,the Permittee shall submit in writing to the Regional
Supervisor, DAQ, the following:
i. A summary of the results of the analytical testing for the previous 12 months.
ii. The total gallons of recycled fuel oil(s) from each approved vendor
combusted at the facility for the previous 12 months.
e. The DAQ reserves the right to require additional testing and/or monitoring of the
recycled fuel oil(s) on an annual basis or without notice.
17. TOXIC AIR POLLUTANT EMISSIONS LIMITATION REQUIREMENT —Pursuant to
15A NCAC 2Q .0711 "Emission Rates Requiring a Permit," for each of the below listed
toxic air pollutants (TAPs), the Permittee has made a demonstration that facility-wide actual
emissions do not exceed the Toxic Permit Emission Rates (TPERs) listed in 15A NCAC 2Q
.0711. The facility shall be operated and maintained in such a manner that emissions of any
listed TAPs from the facility, including fugitive emissions, will not exceed TPERs listed in
15A NCAC 2Q .0711.
a. A permit to emit any of the below listed TAPs shall be required for this facility if
actual emissions from all sources will become greater than the corresponding
TPERs.
b. PRIOR to exceeding any of these listed TPERs, the Permittee shall be responsible
for obtaining a permit to emit TAPs and for demonstrating compliance with the
requirements of 15A NCAC 2D .1100 "Control of Toxic Air Pollutants".
c. In accordance with the approved application, the Permittee shall maintain records of
operational information demonstrating that the TAP emissions do not exceed the
TPERs as listed below:
Permit No. 09935R05
Page 12
Chronic Acute ` Acute
Pollutant Carcinogens Toxicants Systemic Irritants
(Ib/yr) (lb/day) Toxicants (lb/hr)
_ (lb/hr).__
= Acetaldehyde-�'���
i
(75-07-0)
.._.__... _. ............ .. .....- ...._.__--. ......... 1 ......_.. _...._ ....� _______. ........r. _-•-.__.. ......... .�________�... .... _.....
Acrolein 0.02 i
�107.02"g) j
Benzo(a)pyrene (Component of
83329/POMTV & 56553/7PAH) 2.2
(50-32-8)
- ........... _IT. ....__.._....,
Beryllium metal (unreacted) j
(Component of BEC) 0.28
(7440 41-7) ....._ -- __ '.........
- .---- -
CFC-11 ! f
(Trichlorofluoromethane) 140
(75 69-4) - I i
...................... ........... _ ..-_... .......... ............................--- .........................................
Cadmium Metal(elemental -
unreacted, Component of CDC) 0.37 j
(7440-43-9)..
Carbon Disulfide ---^ 3.9
(75-15-0)
_- ......... I ._ ___
Chromium(VI) Soluble Chromate
Compounds (Component of CRC) 0.013
(SolCR6)
Hexachlorodibenzo-p-dioxin
1,2,3,6,7,8 (Component of CLDC) 0.0051
(57653-85-7) '
In-l-lexane 23
(110-54-3)
........... F-
Manganese &Compounds i
( C) ...-_.. .0.63.......... : .
Methyl Chloroform
(71-55-6) 250 64
Methyl Ethyl Ketone j 78 22.4
(78-93 -3.). __ .
Methylene Chloride
1600 0.39
i
Perchloroethylene j 3
(Tetrachloroethylene) (127-18-4) 13000
Phenol 0.24
(108 95..'2)
Permit No. 09935R05
Page 13
Chronic Acute Acute
Carcino ens ; Systemic
4
Pollutant (lb/yr) Toxicants Toxicants Irritants
(lb/day) (lb/hr) (lb/hr)
Styrene --- �
2.7 i
. .._ __
Tetrachlorodibenzo-p-dioxin,
2,3,7,8- (Component of CLDC & 0.0001
83329/POMTV) (1746-01-6)
Toluene
(108-88-3) 98 14.4
Trichloroethylene 4000
(79 01 6)......._............. ................._.... �....._ ---.. ..............._. ......... ......... .... ........._ ._.,.....I
Xylene ---� 57 � 16.4 #
(1330 20-7) .__..
d. To ensure compliance with the above limits, the following restrictions shall apply:
i. production of hot mix asphalt may not exceed 275,000 tons per 12-month
period or 3 00 tons per hour;
ii. particulate matter emissions shall be controlled by the two bagfilters (ID Nos.
CD-1 and CD-2); and
iii. Compliance with this limit shall be established by compliance with the
Synthetic Minor limit, recordkeeping, and reporting requirements outlined in
Specific Condition and Limitation No. 13 above.
B. GENERAL CONDITIONS AND LIMITATIONS
1. TWO COPIES OF ALL DOCUMENTS, REPORTS, TEST DATA, MONITORING DATA,
NOTIFICATIONS, REQUESTS FOR RENEWAL, AND ANY OTHER INFORMATION
REQUIRED BY THIS PERMIT shall be submitted to the:
Regional Air Quality Supervisor
North Carolina Division of Air Quality
Asheville Regional Office
2090 U.S. Highway 70
Swannanoa,NC 28778
828-296-4500
For identification purposes, each submittal should include the facility name as listed on the
permit,the facility identification number, and the permit number.
Permit No. 09935R05
Page 14
2. RECORDS RETENTION REQUIREMENT - Any records required by the conditions of this
permit shall be kept on site and made available to DAQ personnel for inspection upon
request. These records shall be maintained in a form suitable and readily available for
expeditious inspection and review. These records must be kept on site for a minimum of 2
years, unless another time period is otherwise specified.
3. ANNUAL FEE PAYMENT -Pursuant to 15A NCAC 2Q .0203(a),the Permittee shall pay
the annual permit fee within 30 days of being billed by the DAQ. Failure to pay the fee in a
timely manner will cause the DAQ to initiate action to revoke the permit.
4. EQUIPMENT RELOCATION -A new air permit shall be obtained by the Permittee prior to
establishing,building, erecting, using, or operating the emission sources or air cleaning
equipment at a site or location not specified in this permit.
5. REPORTING REQUIREMENT -Any of the following that would result in previously
unpermitted, new, or increased emissions must be reported to the Regional Supervisor,
DAQ:
a. changes in the information submitted in the application regarding facility emissions;
b. changes that modify equipment or processes of existing permitted facilities; or
c. changes in the quantity or quality of materials processed.
If appropriate, modifications to the permit may then be made by the DAQ to reflect any
necessary changes in the permit conditions. In no case are any new or increased emissions
allowed that will cause a violation of the emission limitations specified herein.
6. This permit is subject to revocation or modification by the DAQ upon a determination that
information contained in the application or presented in the support thereof is incorrect,
conditions under which this permit was granted have changed, or violations of conditions
contained in this permit have occurred. The facility shall be properly operated and
maintained at all times in a manner that will effect an overall reduction in air pollution.
Unless otherwise specified by this permit, no emission source may be operated without the
concurrent operation of its associated air cleaning device(s) and appurtenances.
7. This permit is nontransferable by the Permittee. Future owners and operators must obtain a
new air permit from the DAQ.
8. This issuance of this permit in no way absolves the Permittee of liability for any potential
civil penalties which may be assessed for violations of State law which have occurred prior
to the effective date of this permit.
9. This permit does not relieve the Permittee of the responsibility of complying with all
applicable requirements of any Federal, State, or Local water quality or land quality control
authority.
10. Reports on the operation and maintenance of the facility shall be submitted by the Permittee
to the Regional Supervisor, DAQ at such intervals and in such form and detail as may be
Permit No. 09935R05
Page 15
required by the DAQ. Information required in such reports may include, but is not limited
to, process weight rates, firing rates, hours of operation, and preventive maintenance
schedules.
11. A violation of any term or condition of this permit shall subject the Permittee to enforcement
pursuant to G.S. 143-215.114A, 143-215.114B, and 143-215.114C, including assessment of
civil and/or criminal penalties.
12. Pursuant to North Carolina General Statute 143-215.3(a)(2), no person shall refuse entry or
access to any authorized representative of the DAQ who requests entry or access for
purposes of inspection, and who presents appropriate credentials, nor shall any person
obstruct,hamper, or interfere with any such representative while in the process of carrying
out his official duties. Refusal of entry or access may constitute grounds for permit
revocation and assessment of civil penalties.
13. The Permittee must comply with any applicable Federal, State, or Local requirements
governing the handling, disposal, or incineration of hazardous, solid, or medical wastes,
including the Resource Conservation and Recovery Act(RCRA) administered by the
Division of Waste Management.
14. PERMIT RETENTION REQUIREMENT - The Permittee shall retain a current copy of the
air permit at the site. The Permittee must make available to personnel of the DAQ, upon
request, the current copy of the air permit for the site.
15. CLEAN AIR ACT SECTION 112(r) REQUIREMENTS -Pursuant to 15A NCAC 2D .2100
"Risk Management Program," if the Permittee is required to develop and register a risk
management plan pursuant to Section 112(r) of the Federal Clean Air Act, then the
Permittee is required to register this plan with the USEPA in accordance with 40 CFR Part
68.
16. PREVENTION OF ACCIDENTAL RELEASES - GENERAL DUTY - Pursuant to Title I
Part A Section 112(r)(1) of the Clean Air Act "Hazardous Air Pollutants - Prevention of
Accidental Releases - Purpose and General Duty," although a risk management plan may not
be required, if the Permittee produces, processes, handles, or stores any amount of a listed
hazardous substance, the Permittee has a general duty to take such steps as are necessary to
prevent the accidental release of such substance and to minimize the consequences of any
release. This condition is federally-enforceable only.
17. GENERAL EMISSIONS TESTING AND REPORTING REQUIREMENTS - If emissions
testing is required by this permit, or the DAQ, or if the Permittee submits emissions testing
to the DAQ in support of a permit application or to demonstrate compliance, the Permittee
shall perform such testing in accordance with 15A NCAC 2D .2600 and follow all DAQ
procedures including protocol approval, regional notification, report submittal, and test
results approval.
Permit No. 09935R05
Page 16
Permit issued this the 25th of July, 2013.
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
Paul K. Muller, P. .
Regional Air Quality Supervisor
By Authority of the Environmental Management Commission
Air Permit No. 09935R05
ATTACHMENT to Permit No. 09935R05, July 25, 2013
Insignificant/Exempt Activities
_.. . , - .
Exemption Source of Source of
Source Regulation TAPS? Title V
Pollutants?
IES-1 - fuel oil storage tanks ~� 2Q .0102
Yes i
_ (c)(1)(D)(1). . ... ., Yes ?.. ....
;IES-2 - asphalt cement storage tanks) 2Q .0102 ! yes Yes
(30,000 gallon capacity) _. ............:............__. .__..._ . (c)(1)(L)(xii)..!..._.. . _ . _....
IES-3 - one natural gas/propane fired 2 0102 --—
asphalt heater (1.6 million Btu per hour (c)(�(B)(i)(I) Yes Yes
maximum heat input rate)
IES-4 - one aggregate handling system 2Q .0102- _ _.^
i
including RAP handling equipment (c)(2)(E)(i) i No Yes
1. Because an activity is exempted from being required to have a permit or permit modification
does not mean that the activity is exempted from an applicable requirement or that the owner
or operator of the source is exempted from demonstrating compliance with any applicable
requirement.
2. When applicable, emissions from stationary source activities identified above shall be
included in determining compliance with the permit requirements for toxic air pollutants
under 15A NCAC 2D .1100 "Control of Toxic Air Pollutants" or 2Q .0711 "Emission Rates
Requiring a Permit."