Loading...
HomeMy WebLinkAboutAQ_F_0400052_20090724_CMPL_InspRpt i NOI;TH CAROLINA DIVISION OF , - Fayetteville Regional Offico,' j AIR QUALITY "Anson County WasteManagemcntFacility NC Facility IA 0400052 Inspection Report County/FIPS:Anson/007 , Date: 07/27/2009 Taoil ty Data �Comliliamtce Data Anson Count 'Waste ManagerncntFacility InspectimrDate 07/24/2069" M Allied Rd Inspector's Name,Mitch Revels Polk ta6,NC` 28135 (Qperating.Status Operating I Lat: 35d,0,2610n ,Long: 8Od9.7720an Coutpliaoce-Code x fnplimice-inspection' ' SI6,4953 I Refuse Systems+ kctiou Co' i7e FCE NAIL : 562212/Soli Waste Landfill On-Site Inspection Result Compliance Cootaetbats permit Data . Facility Contact Autllorized,Contact 71Toehnical Contact 'permit ,09835/R09 J.Fitzgerald J, Fitzgcrald KurtShancr issued 10/30/2007 District Manager} District Manager, Regional Engineering Expires 9/30/2012 (704)b94.6900" (704)694�6900 Manager Classiticotion SynthuticMinof (901);259-$249 PernritStatns Active: ,insbator's Signahire: r Corutneut5: Date of Signature: 2007 I" — i i I) L"oration: Anson Coonly Waste Management Facility is located at 375 Allied Rd, near I ollcton,NC: Anson;Coutity, Directions: Froni FRO,jakeRaeford Load; Hwy 401 south to Wagram, 32 Wailes.'lustpast Wagram, turn right onto Old Wire Road,(SR 744) to Laurel Hill. Turn-right(west) on Highway74 >and g6,approx 41 mites. Turn right b6tween"NO DMA office building:and bridge ovef'Brown Creek. - Go approx�0,4 mile and the landfill office is on the right. ,Safety'"I{cl nel, safety boots and safety vest is 1"Naired-wheh'near the working face-of the landfill - �" The principal hazardsare from ta'iack traffic'and falls/spraiits from walking;on"the uneven grout tt,, 2) Dpseriptlon,Anson County Waste Management Facility(ACWMF) is a awhieipalsolid waste (MSW i'landfill. ,The facility,was not regilir¢cl to iavo u permit because 2Q .6102(c)(1)(K) exempts MSW-LF from-air permit until Title V threshold as reactied,or exceeded. ACWMF applied fora` synfGetic minor permit to install"and operate a landfill;gas capture and control system}with a candlestick flare. ACWMF first accepted waste in(Y 2001.-,During CX2012, the amount of in plaeo waste is projected to exceed both 2.5 million megagrams and 2.5 inihiort cubic moteas. Ilowevet;when these limits arc " exceeded in an operational permit(PTO)issued by NO Solid Waste,the facility ryust,apply within 90 days for a Title V air permit: Presently AC,VJMF has a,solid waste permit to construct(PT.C) for a -- capacity of4.67 n"' yd3:,NOTL+: I"yd3—10.7646,W and 1�ton=0.9072 MR. The next issued SW" PTO will most likely initicate the Wpermit roquir6ments and NSPS WW W and,MACT AAAA requirements. The,facility alreadylias a gas collection and control system;(GCCS)required by NSPS W WW. Faeility,ch4se to install a GCCS;bef6ic the required date.,This allowed them to buil&carbon credits and piu'stte'a,gas-to energy project: ,The facility may test out per Tier 2 as outlined"iln NSPS I I l t I I I 1 I I W W W.. This facility is permitted raider AirTerniit No. 0983500;effective from.3a Oct 2007,:until 30'Sept 2012. This is the initial compliance inspection by DAQ 3) Current throughputs: Per NC DENR MSW Annual Report FY 2007-2008, total waste in place was 2,07 fin lion tons, with,208,982 toils disposed.in,PY2007-2008., 4) Perndttcd,Souicesare; . Emission Emission Source Control Control System .. Source ill .. Description] I Sysicinr ID i Description" , Municipal Solid Waste Landfill,NSPS W WW,including;', CD-I •Candlestick flare, 75 mmT3tu per hour maximum heat T `,N/A l N/A - ;input Insignificant Sources are: , Date of Exennptioli ;Source of Source of Title V .' Source Applicatlon Regulation TAI's?, . . Pollutants?, =IES-1`-Municipal solid waste ,2Q .0102 09/21/2007 Y68 Yes ,landfill :: IPS-2 r Two diesel aboveground; - 2Q 0102 ;storage tanks, 10,000 gallon capacity, 09/21/2007 Yes ; Yes 1 - each (e)(1)(D)(i) { IFS-3 - Gasoline aboveground .2Q,0102- ' 09/21/2007 Yes " ; Yes; storage tank, 1,000 gallop capacity. IES-4 -Two lcaehate aboveground 2Q .0102,"= store e tanks,250 000 allon 09/21/2907 Yes Yes capacity each g 5), Preinspection Conference: On,24 Juty 2009,t,Mitchell'Revels'ruet with the complianee contact,I Tyter Fitzgerald; We discussed the following: , a) Verified the contacts based on FAC INDER printout, - b) ,'We discussed the desigtr capacity of the facility and the TV.perinit-roquircnients when uiodification;of SW,PTQ increases t¢or greater than 2.5-MM,cuhic meters and2.5 MM Mg. c) We discussed that facility presently holds astateonly permit, A The,faedity is itr the proee$s,of an ownership change. Cs) Inspection Summary: Mr.T,itzge,ratd and I,Mitchell Revels tour the LF, The flare was observed . . ,operating with no opacity above S%; Mr.Fitzgerald indicated that the control�systcm is engineered to i 'cluse,and-not vent to atmosphere(bypassing control,device) during flare downtime:-.This was verified 1 by obserying.the physicaldcsign.of the system (no bypass vent and auto shut-off valve)."The, wellheads,appeared to be well mairrtained and no LE gas odor.was detected,,a good indication"of' no leaks. The,LF flow recorder was observed"and recordhtg'around 200 ofin..: l indicated that when the GCCS is;requh•ed by T4SPS the complete system-will need to meet a all regrurcrneuts and gas flow recording is included as requirement. Presently the facility holds apermit-for the flare,however when Title V N,SPS WW W and,NESIL P AAAA;requirement began the facihty,will need to comply" accordingly, f � . 1 i , , ! 7) Stipulation Review: I a. " SULFUR DIOXIDE CONTROL REQUIREMENT-As required by 15A NCAC 2D .0516 ""Sulfur Dioxide Emissions from Combustion Sources," sulfar dioxide emissions from Flare, (ID No, CD-1)shall riot exceed 2.3;pounds}rer mil]ionBtu]leaf input: " j COlV[K ANCE"INDICATED. The AP42 emission factor for flare combustion of MSW landfill gas is equivalentlo natural gas at"0,0061bslinm$tu." I b. VISIBLE"EMISSIONS CONTROL RFOtJ1REMENT-;As reguiyed by 15A NCAC D 0521 "Controho£Uisible Emissions," visible emissions from Flare(JD No. CD-1),'manufactured after July 1,1971,shall not be more than"20 0crceut opacity when averaged over a six-minute, period, except that six-minute periods averaging"riot rnoic than 87.pereent,otacityinay`occur "not more"than once m any hour nor more than four thnes m any 24-hour perfod. flowevcr;- " sources whichriiust comply with 151A NCAC..2D.p524 "Now-Soui•ce1'crforinance" " Standards"or 1110 "Natioviatl EmissiorrStandards for llazatdous"Air Polhrlant5"most comply with applicable visible emissions requircmonks contained, therein. COMPLIANCE I"NDICATED. Opacity fioitr:tlte flare was lcss than 5°la. l"5A NCAC 2D .0524 "NEW SOURCEPERPORMANCE STANDARDS" - j COMPLIANCE"IINDYCATED."NSPS"W W W"not yet applicable but will likely apply at " next modification:. . " FUOITIUE DUST CONTROL RE:OUIREMENT-As tegtiired by"l5A NCAC 2D A540 "parkiculates£iom Eugitive`Dust"Emissiou Sources," the Perrnittee shalt not cause or allow" fugt)ve dust emissions to cause or contribute to substantive Complainfs or excess;visible emissions beyorlddhe property boundary.If sybstantive,canrplaints or excessive fugitive dust " e'rir$sums"firorn the"facility are obserGed beyond the propertyboundaries for six minutes.in, any one hour(using Reference Method 22-iu 40 CFR,Apportdi 'A),the�owrrcr bfblierator maybe required to submit a fugitive dtist plan as described in 2D :0540(f)." "Fugitive dust emissions" means particlrlate matter from praeess operations that does riot pass " throughA process slack or ventand that is generated within plantproperty"bormdaries from actiYit[es such:a"s: unloading and loading areas, process areas stockpiles, stock-pile working, " plant par-king lots,and plant roads(including access roads and hard roads). " COMPLIANCE INDIGAIM WSoil was moist during the inspection due to recent rain, " 'Cornpliance.wi11 be evaluated during ,future inspection under drier conditions. I " d. TOXJC AIR POLLUTANT EMISSIONS 1,IlVIITATI6N ANDREPORTING REQUIREMENT-Pursuant to,I5A NCAC 2D .1100""Control of Toxic Air.Pollutants," and', in accordance with the a lrrovecJ Opfrcation for an air toxic compliance demonstration;the" " following permit limits strait not be exceeded: ! AffectedSo rec. ' Toxic Air Pollutant �lmissionlAnrit"I " Candlestick"fl re(CD4) "Hydrogen chloride"(7447-01-0) - j 0.47 lblhr �_. COMPLIANCE"INDICATED. Modeling- was based oir"LANDGEM-gene atcd"flow rates " and.indicated less thun"7%"AAL. " , i I I e. CONTROL AND PROHIBITION OF ODOROUS EMISSIONS As required by 15A NCAC 21D .1806 the Perinmce shall not operate"thc eility without implementing management practices or installing and operating odor control equipment sufficient to prevent { odetous emissions from the facility from causing or oontributing to objectionable odors beyond the facility's'boundary COMPLIANCE INDICATED "DAQ has not received any odor complaints. I detected " typical landfill gas odor onsite, but not offensive. 'No odor was detected offste; " f. LIMITATION TO AVOID t5A"N6AC 2Q .0501 1--Pa ismint to 15A NCr1 C ZQ.0315 ` Syothetie"Miiror Facilities;'to avoid the appiioabilltyof 15A NCAC 2Q .0501 "Purpose of" . Section and Requirement for a to, as"requested`by the Perrnittee, facility-wick CQ I erriissions shall be less than ]00 TPY. " COMPC IANCE INDICATED Based on the LANDGEM flowaates CO"was 40 tons in 2061, and will peak at 98 TPY(controlled). The expected 200") emissions arc base on 'a , landfill gas"flowmate of.618 ofiu;as projected in the permit application. ['he potential" emissions"after control are basedon 2,000 cfm, as requosted in the permit application." The potential emissions-before control are based oii 2,500 efnr. lnh ,present LF.gas " flow rate wasindicated"-to be.200-250 efm. g. " TOXIC AIR,POLLUTANT EMISSIONS LIMITATION"REOUII2EML,NT:-,Pursuant to 15A NCAC 2Q".0711 "Emission Rates Requiring a Pcr nit, for oachof the below listed toxic air " pollutants(TAPs),the:Permittee has"madc a"demonstration thatfacility-wide actual emissions do not exceed the Toxic Permit Emission Rates(.TPERs) listed m"15ANCAC 2Q".071 L The facility shall be operated,and-maintained ip such a manner that emission's of any listed TAPS " item the facility; me fugitive ettiissions,will snot exceed TPERs listed in 15A NCAC 20 ,oill. The Perinittee`shall maintain records of operational information demonstrating that the TAP -emmsssions do riot exceed'_the TPERs as listed below: I Chronic Acute Systemic aYciuo ens Acute It•ri"tants Pollutant (lblY) Toxicants Toxicants (Iblday) (ib/lir) - t ' 'Benzene(71-43-2) Vinyl chloride(75-01= 26 I '4) i I " COMPL[f�NCfi INDICATED, P".er the permit review,tinder normal MSW landfill " operations;these Ievels cannot be exceeded. 8)" Reporting requirements: Presently no reportipgis-required.. " j 9)'1112R Status: COMPLIANCE INDICATED Typical MSW landfill does notuse nor store j chemical compounds subject W requirement for a written RMP. " JOI Comments and Compliance Statement. Faeility'appears in compliance. Based on inspection and NC"Solid Waste documentation,"this facility will become subject to TV after next modification'to" increase capacity per a Solid Waste Permit to.Operate, " Next inspection should be after"extended dry weather to evaluate fugitive dust"control. i I I C " I i 2) 5-Year Compliance,0,istory: - No history of noncompliance. /mr cc: . DAQ,Cenfral Filcs