HomeMy WebLinkAboutAQ_F_0400028_20111018_CMPL_InspRpt NORTH CAROLINA DIVISION OF � Fayetteville Re��iai�al Office
AIR QUALITY � CEMEX Construction Materials
I Atlantic,LLC-tivadeshoro
Inspection Report I NC Facility ID 0400028
Date: 10f20;2011 County%FIPS: Anson/007
Facility Data Compliance Data
C) h4EX Construction Materials Atlantic,LLC-Wadesboro Inspection Date 10i18/2011
Route 4,Box 110 Inspector's Name Cindy Grimes
Wadesboro,NC 28170 j Operating Status Operating
Lat: 34d 58.6320m Long: 80d 5.5620m Compliance Code Compliance- inspection I
SIC: 3273 /Ready-Mixed Concrete Action Code FCE
NAICS: 32732/Ready-Mix Concrete Manufacturing On-Site Inspection Result Compliance
i
L� Contact Data �� Permit Data
Facility Contact Authorized Contact Technical Contact
Perinit 04009/RI
Alvin Goins ( La+rry McSwain Johnny Tapia Issued 5 14,'200 i
Expires es 4l30/2012
Plant Manager VP!GM Carolinas Environmental Manager ! I
(704)694-3201 Division (704)598-2058 Classification Small
Permit Status Active I
_ (864)605-9877 1
Inspector's Signature: Comments: — — ---
Date of Signature: l �
MACT/GACT Applicability: None (facility has no known generators on site).
1) Location
CEMEX Construction Materials-Wadesboro is located at 1295 US Hwy 74 West.Wadesboro,NC,Anson County.
Directions
From FRO,take Hvv,N, 401 South to Wagram. Turn right at Old Wile Road (Hwyl 44) and go �- 11 ?!miles to
Laurel Hill. Turn right onto Hivy 74 West and go—35 miles to Wadesboro. Go all the way through town, drive
through the traffic light for Hwy 52 North and then drive another 50 yards. Look for a small CEMEX sign at a
gravel driveway on the left hand side; a Waffle House is immediately after the plant.
Safety Considerations: Standard DAQ safety equipment required. Watch for cement trucks entering and exiting.
2) Facility and Process Description
CEIMEX Construction Materials, LP -Wadesboro Plant is a batch concrete mixing plant. This facility is
permitted under Air Permit No. 04009R10, effective from 14 May 2007 until 30 April 2012. Cindy
Grimes conducted the last compliance inspection on 20 April 2011.
Fly ash and cement are brought in by transfer truck and loaded pneumatically into silos for storage.
01, ,_ ,. , , ,_ •,, , L _ i i led.
_ , f _._, ,_ ,__.,
vtner ITlaierials Such as Sand aria gravel are stocxpueU oil file-faro iinii1 iIUV( i. �.cu�eiit is tiiaci�wuen
delivery trucks pull under the loading shoot. Once the truck is in place nuclei-the loadout shoot, sand and
gravel are loaded into a bin on the yard and belt conveyed into the truck through the loadout slioot.Next,
a measured amount of cement and fly ash from the storage silos is transferred into a weigh hopper above
the loadout shoot. Once the proper amount of cement and fly ash for that batch is collected, it is dumped
into the truck and mixed while in transport to the delivery site.
a) Throughputs for 2010
Employees: 0 (Sallie in 2009)
Hours: 0 (same in 2009)
Production: 0 (same in 2009)
b) Permitted Sources
Emission Emission ,Source _F Control (( Control System
Source ID Description System 1D ( Description
ES-1 One cement silo F—CD-1 _ One(1) bagfilter(250 square feet of filter
larea) central collector
ES-2 One flyash silo CD-I One(1)bagfilter(250 square feet of filter
area) central collector I
ES-3 One wcgh hopper- CD-1 One(1)bagfilter(250 square feet of filter
i area) central collector
TM _ 10ne truck mix operation ( N/A N/A
e) Insignificant Sources
- �
Date of Exemption Source of Source of Title V j
Source Application Regulation ( TAPO Pollutants?
I-Sand/Agg—Yard 2Q .0102 �j
04/24/2007 No Yes
sand/ago0veigh hopper (c)(2)(E)(i)
3) Inspection Summary
Oa 18 October 2011;I(Cindy Grimes) drove to this facility to conduct its permit renewal compliance
inspection.I saw no activity or presence of personnel on site,and it looked like there had been no one here for
quite some time. There were also cement dividers blocking the entryway into this facility.
Note: This facility has not operated since 2008 due to the slow economy.
4) Permit Stipulations
Per permit.
5) Reporting Requirements
There are no reporting requirements in this facility's current permit.
6) 112R Status
This facility neither uses nor stores chemical compounds that require a written risk management plan under the
Clean Air Act, Section 112R.
7) DAQ Compliance History
This facility has had no previous DAQ violations in its permitted History.
8) Comments and Compliance Statement
This facility has not operated since 2008 and does not plan to reopen in the foreseeable future per CEMEX.
n.. ?n n + t- ..nni i T 1 T 1„„ ., Ir +ho 1 +�i 1 ,,� n,- a„d PcIL:,cal COraact at tl;lS
k-M, ....V Vc'C)Ue Gvl1, 1 emarlVU Jv111xtt_y �.aY1a, �iiv 1..uViivnliier��c.i.i uiiu C; v
facill�._i7:�_. a.+� 1..,1..:,-... -r+1'e,+:,��„�'.-..,,,o +1-,� - . 1 ,� cv� r7 i f lio haul ,-,1an;,ed ^:: ;'e;�elVin<T �l;e
ity,jli.jl i i]'_ta, 111---aware�! -I !1111b 11Sd111V 1v1 "3, �enevv as process arid .., i
permit. I also offered my assistance in the emissions inventory procedure. As of this report,I had not received a
response.
CEMEX Construction Material s-Wadesboro appeared to be in compliance on 18 October-2011.
/clg
cc: DAQ Central Files