NORTH CAROLINA DIVISION OF Fayetteville Regional Office
AIR QUALITY Anson County Waste Management Facility
NC Facility ID 0400052
Inspection Report County/FIPS:Anson/007
Date: 06/27/2011
Facility Data Compliance Data
Anson County Waste Management Facility Inspection Date 06/24/2011
375 Allied Rd Inspector's Name Mitch Revels
Polkton,NC 28135 Operating Status Operating
'l Lat:35d 0.2610m Long: 80d 9.7720m Compliance Code Compliance-inspection
SIC: 4953/Refuse Systems Action Code FCE
NAICS: 562212/Solid Waste Landfill On-Site Inspection Result Compliance
Contact Data Permit Data
i
Facility Contact Authorized Contact Technical Contact permit 09835/R00
J.Fitzgerald J.Fitzgerald Kurt Shaner Issued 10/30/2007
Expires 9130/2012
District Manager District Manager Regional Engineering Classification Synthetic Minor
(704)694-6900 (704)694-6900 Manager
Permit Status Active
A
(901)259-8249
Inspector's Signature: „ Comments:
. 4�A
Date of Signature: re w
This facility has no RICE,therefore not subject to MACT ZZZZ.
1) Location: Anson County Waste Management Facility is located at 375 Allied Rd. near Polkton,NC.
Anson County.
Directions: From FRO,take Raeford Road,Hwy 401,south to Wagram,—32 miles. Just past
Wagram,turn right onto Old Wire Road(SR 144)to Laurel Hill. Turn right(west)on Highway 74
and go approx 41 miles. Turn right between NC DMV office building and bridge over Brown Creek.
Go approx 0.4 mile and the landfill office is on the right.
Safety: Helmet, safety boots and safety vest is required when near the working face of the landfill.
The principal hazards are from truck traffic and falls/sprains from walking on the uneven ground.
2) Description:Anson County Waste Management Facility(ACWMF)is a municipal solid waste
(MSW)landfill. The MSW facility is not required to have a permit as an emission source, because
2Q .0 1 02(c)(1)(K) exempts MSW LF from air permit until Title V threshold as reached or exceeded.
ACWMF applied for a synthetic minor permit to install and operate a landfill gas capture and control
system with a candlestick flare. Therefore,ACWMF has a state air permit for the candlestick flare.
ACWMF first accepted waste in CY 2001. During CY2012,the amount of in place waste is projected
to exceed both 2.5.million megagrams and 2.5 million cubic meters. Therefore,when these limits are
exceeded in an operational permit(PTO) issued by NC Solid Waste,the facility must apply within 90
days for a Title V air permit. Presently ACWMF has a solid waste permit to construct(PTC)for a
capacity of 4.67 mm yd3. NOTE: 1 yd3=0.7646 m3 and 1 ton=0.9072 Mg. The next issued SW
PTO will most likely trigger the TV permit requirements and NSPS WWW and MALT AAAA
requirements. The facility already has a gas collection and control system(GCCS)required by NSPS
WWW. Facility chose to install a GCCS before the required date where calculated NMOC reach 50
Mega Grams per year. This allowed them to build carbon credits and pursue a gas-to energy project.
The facility may test out per Tier 2 as outlined in NSPS WWW..
This facility is permitted under Air Permit No. 09835R00, effective from 30 Oct 2007, until 30 Sept
2012.
3) Current throughputs: Per the most recent data online indicates NC DENR MSW Annual Report FY
2008-2009,total waste in place was 2.07 million tons,with 208,982 tons disposed in FY 2007-2008.
During this inspection on 6/24/2011,the landfill gas flow rate, 400 acfm,was observed at the flare
recorder.
4) Permitted Sources are:
Emission Emission Source Control Control System
Source ID Description System ID Description
Municipal Solid Waste Landfill,NSPS WWW,including:
CD-1 lCandlestick flare,75 mmBtu per hour maximum heat N/A N/A
E ,input
Insignificant Sources are:
Source Date of f Exemption .'Source of ' Source of Title V
Application Regulation TAPs! Pollutants?
_ - _
A ES-1 - Municipal solid waste
09/21/2007
! !2Q .0102 ' yes Yes
,landfill
`IES-2 Two diesel abovegroundi_._...�..____.�......_...M._.._...€
!2Q .0102
storage tanks, 10,000 gallon capacity j 09/21/2007 '(c)(1)(D)(i) Yes Yes
::each '
DIES-3 - Gasoline aboveground I `2Q .0102
09/21/2007 Yes Yes
{storage tank, 1,000 gallon capacity
IES-4 - Two leachate aboveground
t
;storage tanks, 250,000 gallon ; 09/21/2007 `2Q .0102 yes Yes f
} i(c)(2)(E)(i)
capacity each i
5) Preinspection Conference: On 24 June 2011, I,Mitchell Revels met with the Mr. William Melton.
We discussed the following:
a) Verified the contacts based on FACFINDER printout.
b) We discussed the design capacity of the facility and the TV permit requirements when
modification of SW PTO increases to or greater than 2.5 MM cubic meters and 2.5 MM Mg.
c) We discussed that facility presently holds a state only permit with a limit of 2000 acfm to
flare and a weekly recordkeeping requirement.
d) The facility has completed the ownership change.
e) The facility presently has 19 operating gas extraction wells, 4 leachate clean headers and an
average acceptance rate of 1100 TPD. It was stated by Mr. Melton that one gas well has been
abandoned due to infiltration of oxygen.
6) Inspection Summary: Mr. William and I,Mitchell Revels tour the LF. The flare was observed
operating with no opacity. Mr. William indicated that the control system is engineered to close and
not vent to atmosphere(bypassing control device)during flare downtime. This was verified by
observing the physical design of the system(no bypass vent and auto shut-off valve). The wellheads
appeared to be well maintained and no LF gas odor was detected,a good indication of no leaks. The
LF flow recorder was observed and recording around 400 cfm... I indicated that when the GCCS is
required by NSPS the complete system will need to meet all requirements and gas flow recording is
included as a requirement. Presently the facility holds a permit for the flare, however when Title V,
NSPS WWW and NESHAP AAAA requirement began the facility will need to comply accordingly.
7) Stipulation Review:
a. SULFUR DIOXIDE CONTROL REQUIREMENT-As required by 15A NCAC 2D .0516
"Sulfur Dioxide Emissions from Combustion Sources," sulfur dioxide emissions from Flare
(ID No. CD-1)shall not exceed 2.3 pounds per million Btu heat input.
COMPLIANCE INDICATED. The AP42 emission factor for flare combustion of MSW
landfill gas is equivalent to natural gas at 0.0061bs/mmBtu.
b. VISIBLE EMISSIONS CONTROL REQUIREMENT-As required by 15A NCAC 2D .0521
"Control of Visible Emissions," visible emissions from Flare(ID No. CD-1), manufactured
after July 1, 1971, shall not be more than 20 percent opacity when averaged over a six-minute
period,except that six-minute periods averaging not more than 87 percent opacity may occur
not more than once in any hour nor more than four times in any 24-hour period. However,
sources which must comply with 15A NCAC 2D .0524 "New Source Performance
Standards" or .1110 "National Emission Standards for Hazardous Air Pollutants"must
comply with applicable visible emissions requirements contained therein.
COMPLIANCE INDICATED. Opacity from the flare was 0
15A NCAC 2D .0524,"NEW SOURCE PERFORMANCE STANDARDS" -
COMPLIANCE INDICATED. NSPS WWW not yet applicable but will likely apply at
next modification.
c. FUGITIVE DUST CONTROL REQUIREMENT-As required by 15A NCAC 2D .0540
"Particulates from Fugitive Dust Emission Sources,"the Permittee shall not cause or allow
fugitive dust emissions to cause or contribute to substantive complaints or excess visible
emissions beyond the property boundary.If substantive complaints or excessive fugitive dust
emissions from the facility are observed beyond the property boundaries for six minutes in
any one hour(using Reference Method 22 in 40 CFR,Appendix A),the owner or operator
may be required to submit a fugitive dust plan as described in 2D .0540(f).
"Fugitive dust emissions"means particulate matter from process operations that does not pass
through a process stack or vent and that is generated within plant property boundaries from
activities such as: unloading and loading areas,process areas stockpiles, stock pile working,
plant parking lots, and plant roads(including access roads and haul roads).
COMPLIANCE INDICATED. No dust or fugitive PM was observed leaving property.
The facility has a large buffer with no nearby neighbors. The access road is paved..
d. TOXIC AIR POLLUTANT EMISSIONS LIMITATION AND REPORTING
REQUIREMENT-Pursuant to 15A NCAC 2D .1100 "Control of Toxic Air Pollutants," and
in accordance with the approved application for an air toxic compliance demonstration,the
following permit limits shall not be exceeded:
Affected Source Toxic Air Pollutant _ Emission Limit
=Candlestick flare(CD-1) JHydrogen chloride(7647-01-0) 0.47 lb/hr
! f
COMPLIANCE INDICATED. Modeling was based on LANDGEM-generated flow rates
and indicated less than 7%AAL.
e. CONTROL AND PROHIBITION OF ODOROUS EMISSIONS -As required by 15A
NCAC 2D .1806 the Permittee shall not operate the facility without implementing
management practices or installing and operating odor control equipment sufficient to prevent
odorous emissions from the facility from causing or contributing to objectionable odors
beyond the facility's boundary
COMPLIANCE INDICATED DAQ has not received any odor complaints. I detected
typical landfill gas odor onsite,but not offensive. No odor was detected offsite.
f. LIMITATION TO AVOID 15A NCAC 2Q .0501 -Pursuant to 15A NCAC 2Q .0315
"Synthetic Minor Facilities,"to avoid the applicability of 15A NCAC 2Q .0501 "Purpose of
Section and Requirement for a Permit," as requested by the Permittee, facility-wide CO
emissions shall be less than 100 TPY:
COMPLIANCE INDICATED Based on the LANDGEM flow rate, CO was 40 tons in
2007, and will peak at 98 TPY(controlled). The expected 2007 emissions are base on a
landfill gas flow rate of 618 cfm, as projected in the permit application. The potential
emissions after control are based on 2,000 cfm, as requested in the permit application.
The potential emissions before control are based on 2,500 cfm. The present LF gas
flow rate was indicated to be 400 cfm.
g. TOXIC AIR POLLUTANT EMISSIONS LIMITATION REQUIREMENT-Pursuant to 15A
NCAC 2Q .0711 "Emission Rates Requiring a Permit," for each of the below listed toxic air
pollutants(TAPS),the Permittee has made a demonstration that facility-wide actual emissions
do not exceed the Toxic Permit Emission Rates(TPERs)listed in 15A NCAC 2Q .0711.The
facility shall be operated and maintained in such a manner that emissions of any listed TAPs
from the facility, including fugitive emissions,will not exceed TPERs listed in 15A NCAC
2Q .0711.
The Permittee shall maintain records of operational information demonstrating that the TAP
emissions do not exceed the TPERs as listed below:
Chronic i Acute Systemic
Carcinogens Acute Irritants ;
Pollutant. ? Toxicants Toxicants lb/hr(lb/yr) f
(lb/day). (lb/hr). . .
3 ;
f i
Benzene(71-43-2) 8.1
;Vinyl chloride(75-01- � 26
COMPLIANCE INDICATED. Per the permit review, under normal MSW landfill
operations,these levels cannot be exceeded.
8) Reporting requirements: Presently no reporting is required..
9) 112R Status: COMPLIANCE INDICATED Typical MSW landfill does not use or store chemical
compounds subject to requirement for a written RMP.
10) Comments and Compliance Statement: Facility appears in compliance.Based on inspection and
NC Solid Waste documentation,this facility will become subject to TV after next modification to
increase capacity per a Solid Waste Permit to Operate.
Next inspection should be after extended dry weather to evaluate fugitive dust control.
11) 5 Year Compliance History:
No history of noncompliance.
/mr