HomeMy WebLinkAboutAQ_F_0400052_20120507_ST_RvwLtr A74 .
NCDENR
North Carolina Department of Environment and Natural Resources
Beverly Eaves Perdue, Governor Division of Air Quality Dee Freeman,Secretary
Sheila C. Holman, Director
7 May 2012
Mr. J.Fitzgerald,District Manager
Anson County Waste Management Facility
375 Allied Road
Polkton,NC 28135
SUBJECT: Central Office Review of Source Retest Results-
Tier 2 Non-Methane Organic Compounds
Air Quality Permit No.09835R00
Anson County Waste Management Facility
Polkton,North Carolina,Anson County
Facility ID: 0400052 Fee Class: Synthetic Minor
Dear Mr. Fitzgerald:
The Division has reviewed your source retest report that was received by our Central Office
on 17 January 2012. There was one report that was submitted for New Source Performance Standard
Tier 2 Testing for Non-Methane Organic Compounds (NMOC) emitted from the municipal solid
waste landfill. The test was performed on 15 December 2011. On 19 April 2012, this Division
determined that the subject test performed at your facility was an acceptable source test. The review
indicates that compliance with Air Permit No.09835R00 is indicated for this source and that the site-
specific test results are acceptable for calculating annual NMOC emissions from the landfill. A copy
of the determination memorandum, issued by Mr. James Hammond, of the N.C. Division of Air
Quality, Stationary Source Compliance Branch, is attached.
Should you have any questions regarding this matter, please contact Neil Joyner,
Environmental Specialist, at(910)433-3300, in the Fayetteville Regional Office.
S`'-cerely,
`Steven F. Vozzo
Regional Air Quality Supervisor
Fayetteville Regional Office
SFV\caj
Attachment-DAQ RCO review(1),dated 19 April 2012 [2011-224ST]
cc:FRO Files(with attachment)
Fayetteville Regional Office-Division of Air Quality �7One
225 Green Street,Suite 714,Fayetteville,North Carolina 28301-5043 1 V olthCarolina
Main Phone: 910-433-3300\DAQ Fax:910-485-7467 \ Internet: http://www,ncair.org
An Equal Opportunity/Affirmative Action Employer-50%Recycled/10%Post Consumer Paper Nah(rally
,-
Anson County
Division of Air Quality
April 19, 2012 RECEIVED
MEMORANDUM '
To: Steven Vozzo,Fayetteville Regional Office
From: James E. Hammond, Stationary Source Compliance Branch(SSCB)
Subject: Anson County Waste Management Facility, Polkton, Anson County,North Carolina
Facility ID 0400052; Permit No. 09835R00
Tier 2 Emissions Testing for Non-methane Organic Compounds from the Municipal
Solid Waste Landfill Performed December 15, 2011
by Riley, Park, Hayden&Associates, Inc. (RPH)
Tracking No. 2011-224st
The subject test report has been reviewed and is deemed acceptable. This is a New Source
Performance Standard (NSPS) Tier 2 retest in accordance with 40 CFR 60.754(b). The site-
specific test results are acceptable for calculating annual non-methane organic compounds
(NMOC) emissions from the landfill.
The source is a municipal solid waste landfill with a footprint of approximately 40 acres. A
landfill gas collection and control system (GCCS), consisting of vertical extraction wells, lateral
piping, and a 2,500 standard cubic feet per minute (sefm) flare (CD-1), is currently installed on
Cells IA and 113. Note this system does not control emissions from all areas where there is
currently waste in place (Cells I through 1D).
The landfill is subject to 40 CFR 60 Subpart WWW Standards of Performance for Municipal Solid
Waste Landfills. The regulation requires landfills with design capacities greater than 2.5 million
mega-grams and 2.5 million cubic meters to calculate annual emissions of NMOC. For an emissions
rate greater than 50 Mglyr, the landfill is required to install a landfill gas collection and control
system. Subpart WWW also allows the landfill to obtain site-specific data on non-methane organic
compound (NMOC) emissions.
Surface emission monitoring was performed to detect the methane concentration at the surface in the
vicinity of the GCCS. Background emissions were determined to be acceptable at 0.15 ppm.
Landfill gas testing was performed for emissions of NMOC as hexane using the procedure
specified in Subpart WWW using EPA Methods 25C and 18. RPH collected samples from a
sampling port located in the main header upstream of the flare, blower and condensate knockout
pot. Three samples and one back up sample were obtained from the header. "Flare2" sample
canister leaked before reaching the laboratory. Three canisters were intact and acceptable for
analysis. The average NMOC emissions from the landfill were 483 ppmv as hexane.
The average NMOC emissions rate was then used in the Tier 2 equation developed by USEPA to
project average annual NMOC emissions from the landfill for the next 5 years. The calculated