Loading...
HomeMy WebLinkAboutAQ_F_1900015_20140224_CMPL_Fac-Ltr � 985 Corinth Road (Plakeboard M l:919- , North Carolina 27559 Tel:919-642 6600 Toll Free:855-427-2826 COMMITTED•M SIONATE Fax:919-545-5822 SUSTAINABLE February 21, 2014 Mr. Michael Pjetraj, P.E. f NCDENR—Division of Air Quality F F B Z 4 2�14 217 West Jones Street 1641 Mail Service Center Raleigh, NC 27699-1641 r Subject: Deferral of Enforcement Request—Wellons Wood Furnace Bypass Moncure, Chatham County, North Carolina Air Permit#03449T43 Dear Mr. Pjetraj: As you are aware,Arauco's Moncure, North Carolina facility entered in to Special Order by Consent 2013-002 on June 3`", 2013 due to violation of Title V 03449 condition 2.1.F.5.a limiting the particleboard dryers to 20%opacity emissions. The Wet ESP unit is controlling the emissions from three wood combustion units:the Wellons furnace used to heat thermal oil for the particleboard press and two furnish dryer burners. The Wellons unit burns primarily hog fuel while the dryer burners burn sanderdust, a byproduct of the particleboard sanding process. In an effort to attain the 20%opacity limit,Arauco staff recently permitted an existing Wellons natural gas burner that had not been commissioned or permitted since the 1987 startup of the Particleboard facility. The Wellons natural gas burner permit was issued on January 10, 2014. Now, the Wellons has three permitted operating scenarios: combust wood with emissions directed to dryers controlled by Wet ESP, combust natural gas with emissions directed to dryers controlled by Wet ESP, and combust natural gas with emissions vented to atmosphere. Deferral of Enforcement Arauco has recently received proposals for rebuilding and refurbishing the natural gas burner in the Wellons unit. Prior to performing this work,Arauco would like to attempt to run the Wellons while firing wood in bypass to see if the Wet ESP, while controlling PM from the two dryers combusting sanderdust, can meet the 20%opacity limit. The Wellons is currently subject to 40 CFR 63 Subpart DDDD PCWP MACT as the wood-fired operating scenario emits through PCWP MACT equipment and is controlled by PCWP MACT control devices. The formaldehyde emitted from the combustion of wood residuals will not be controlled. The Wellons burner is subject to 15A NCAC 2D.0516 SOZ emission limits for combustion devices but should not violate this standard due to inherently low sulfur content in wood fuels. The Wellons is also subject to the particulates emission standard for wood-burning indirect heat exchangers 15A NCAC 2D.0504. This emission source has never been source tested so there is a potential to exceed 0.365 total particulate Ibs/MMBtu heat input during this test event. The emissions from the Wellons in bypass will also potentially exceed the 20%opacity limit set by 15A NCAC 2D.0521. Arauco requests a deferral of enforcement for any excess emissions caused by the bypass of the Wellons stack during a testing period preferably to occur within the next two weeks pending the weather(February 24th-March 7th) not to exceed 2 hours.Arauco has several Method 9 certified observers that will perform Method 9 observations during the trial. If you have any questions related to this request, please do not hesitate to contact John Bird, Moncure's EHS Manager at 919-642-6658. Sincerely, Tom Quesenberry Site Manager