HomeMy WebLinkAboutAQ_F_0400056_20141112_ST_RvwLtr NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary 12 November 2014 Martin Petchul Managing Director,Engineering and Technical Services Piedmont Natural Gas,Inc. Post Office Box 33068 Charlotte,North Carolina 28233 -- SUBJECT: Central Office Review of Source Test Result-Source ID Nos. COMP01-04 Air Quality Permit No. 10097ROO _ Piedmont Natural Gas,Inc. -Wadesboro Wadesboro,North Carolina,Anson County Facility ID: 0400056 Fee Class: Title V Dear Mr. Petchul• The Division has reviewed your source test report that was received by our Central Office on 25 April 2014. This report was from nitrogen oxides, carbon monoxide, and volatile organic compound testing of natural gas-fired compressor engines COMPOI through 04,which was conducted on 25 to 27 April 2014. On 29 October 2014, this Division determined that the subject testing performed at your facility was an acceptable source test. The review indicates that compliance with Air Permit No. 10097ROO is indicated for these sources. A copy of the determination memorandum issued by Mr. James Hammond,of the N.C.Division of Air Quality, Stationary Source Compliance Branch, is attached. Should you have any questions regarding this matter, please contact Mr. Neil Joyner, Environmental Specialist, at(910)433-3300, in the Fayetteville Regional Office. erel Steven F. Vozzo Regional Air Quality Supervisor Fayetteville Regional Office SFV\caj Attachment: DAQ RCO review(1),dated 29 October 2014 [2014-007ST] cc: ❑ FRO Files(w/attachment) Fayetteville Regional Office 225 Green Street,Suite 714,Fayetteville,North Carolina 28301-5095 Main Phone: 910433-3300 \ Internet: http://www,ncdenr.gov An Equal Opportunity 1 Aflirmmve Action Employer—Made in part by Recycled Paper Anson County to� DIVISION OF AIR QUALITY October 29, 2014 MEMORANDUM To: Steven Vozzo,Regional Supervisor,Fayetteville Regional Office From: James E. Hammond, Stationary Source Compliance Branch(SSCB) i1 Subject: Piedmont Natural Gas(PNG),Wadesboro Compressor Station,Anson County,North Carolina Facility ID'0400056;Permit No. 10097ROO Initial Emissions Testing of Compressor Engines ID COMPOI, COMP02,COMP03, COMP04 Performed April 25 to 27,2014 by Air-Tech Environmental Corporation(Air-Tech) DAQ Tracking No.2014-007st _ This is a revision to the October 1, 2014 memo issued for DAQ tracking No. 2014-007st. This memo supersedes the October 1,2014 memo. Air-Tech performed initial testing on COMPOI, COMP02, COMP03,and COM204 compressor engines. Emission sources COMP01 through COW04 are four natural gas-fired,four-stroke lean bum(4FSLB) internal combustion reciprocating engines(4,735 horsepower rating)equipped with oxidation catalyst CO control on each engine. Each engine powers a natural gas compressor. The test report has been reviewed and is deemed acceptable. EPA reference methods(RM)performed were:RM10 for carbon monoxide(CO),RM25A for total volatile organic compounds(VOC),RM18 for methane(CH,), and Method RM7E nitrogen oxides(NO ) emissions for COMPOI, COMP02, COMP03, and COMP04. COMPOI, COMP02,COMP03,and COMP04 are subject to: s 40 CFR 60 Subpart JJJJ Standards of Performance for Stationary Spark ignition Internal ,Combustion Engines e 40CFR 63-Subpart ZZZZ NationalEmission Standardsfor Hazardous Air Pollutants for ,Reciprocating Internal Combustion Engines(RICE MALT) e 15A NCAC 2D .1423 Large Internal Combustion Engines(PACT).. 63 Subpart ZZZZ states that a facility subject to both 60 Subpart JJJJ and 63 Subpart ZZZZ meets the requirements of 63 Subpart ZZZZ by meeting the requirements of 60 Subpart JJJJ. SSCB has reviewed the testing. The results are acceptable to establish CO and VOC emission factors for PSD/NSR avoidance assessments as required by permit section 2.2 A.3.b. Results are also acceptable to demonstrate compliance with the applicable standards. The test results, limits, and operating parameters' are tabulated on the following page;' The test results are acceptable and demonstrate compliance of COMP01 through COMP04 for applicable NOx, CO and VOC emissions requirements. If there are any questions concerning this review,please contact me at(919)707-8412 orjames.hammond@ncdenr.gov. cc: Central Files-Anson County 1BEAM Documents 0400056 Steven Vozzo FRO Regional Supervisor October 29, 2014 Paget DAQ Tracking No.2014-007sf Table 1: Piedmont Natural Gas-Wadesboro CO Emissions During April 25 through 27,2014 Testin Rated Engine Tested _ Power Load CO Emissions Compliance Engine (BHF HP) Standard CO Emissions Indicated* 0.02 g/hp-hr COMPOl 4,705 1.8 mvd 15%002 Yes 2.0 gthp-br 0.03 g/hp-hr COMP02 4,735 4,825 or 3.0 p mvd 15%002 Yes 270 ppmvd@l5%O2 0.03 glhp-hr COMP03 4,546 (60 Subpart JJJJ) 2.5 mvd 15%O2 Yes 0.03 gmp-hr COMP04 4,506 2.4 ppmvd 15%002 Yes *Note: PNG-Wadesboro elected to test for CO reduction across the oxidizer and exhaust emissions. Table 2:Piedmont Natural Gas-Wadesboro NO.Emissions:During April 25 through 27,2014 Testing Rated Engine Tested Power Load NOx Emissions Compliance Engine (BHP) (BHP) Standard NOx Emissions Indicated 0.33 g/hp-hr COMP01 4,705 1'0 p 22 mvd 15%02 Yes or 0.28 g/bp-hr COM202 4825 82ppmvd@15%02, 20 mvd 15%02 Yes 4,735 (60 Subpart JJJJ) 0.39 g/hp hr COMP03 4 546 and 22 mvd 15%0 Yes ' 125 ppmvd@15%O2 VV 0.43 g/hp-hr 2 COMP04 1 4,506 1 (2D .1423) 24 ppmvd 15%O2 Yes Table 3: Piedmont Natural Gas-Wadesboro VOC in terms'ofNMOC(Methane subtracted)Emissions During April 25 through 27,2014 Testing Rated Engine `Tested Power Load VOC Emissions Compliance Engine (BHP HP) Standard' NMOC Emissions' Indicated Smp hr GOMP01 4,705. 0 pmvdQ3H8 15%O2 Yes 0.7 g/hp-hr 0.49 g/hp-hr COMP02 "4 735 4,825 or 34.2 mvdC3H8 15%O2 Yes 60 ppmvdC3Hg@l5%o02 . 01 g(hp-hr, COMP03 4,546. (60 Subpart 7JJJ) 5.0 mvdC3H8 15%. Yes 4p-hr COMP04 4,506 0 mvdC3H8 15%OZ Yes 'VOC is in terms of propane. 'NMOC means non-methane organic compounds. Methane has been subtracted from total VOC.