HomeMy WebLinkAboutAQ_F_1800419_20150515_ST_RvwMemo DIVISION OF AIR QUALITY May 15, 2015 MEMORANDUM To: Ron Slack, Mooresville Regional Office From: Gary Saunders, Stationary Source Compliance Branch Subject: Prysmian Cables and Systems USA, LLC Claremont, Catawba County,North Carolina Facility ID 1800419,Permit No. 07334T25 Tracking No. 2014-052ST NOx Control Efficiency and Emission Factor Testing Performed April 15, 2014 by Analytical Testing Company(ATC). SSCB has reviewed the subject emissions test report. The test results are acceptable to establish the control efficiency for the Dry Scrubber 2DS, demonstration of avoidance of PSD requirements and development of emission factors for future emission inventory estimation calculations. The emissions sources are the Overcladding Units(cells 6, 7 and remaining cell 5 units)under emission source ID ES-9a. A dry scrubber using a fabric filter and lime injection is used to control emissions. EPA Method 7E was performed on April 15,2014 at the inlet and outlet of the dry scrubber fabric filter to determine the emission rate and removal efficiency of NO,. Although there were slight differences in the inlet and outlet volumes,they were within the expected error range for measurement of volumetric flow rates. The inlet emission rate of NO,,was determined to be 41.421b/hr,while the outlet emission rate was 37.59 lb/hr. Annual potential emissions of NOx are reported as 181.41 tons/yr at the inlet and 164.64 tons/yr at the outlet. It appears that the emission factors may also be used for future emission inventory calculations. If you have any questions regarding the results of this review,please contact me at(919) 707-8413 or gary.saunders@ncdenr.gov cc: Central Files, Catawba County IBEAM Documents-1800419