Loading...
HomeMy WebLinkAboutAQ_F_0100010_20140813_CEM_RptRvwLtr PUMA Ate= NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary August 13, 2014 Mr. Alan Skrzypczak Facility Manager Stericycle,Inc. Post Office Box 310 Haw River,North Carolina 27258 SUBJECT: Review of 2014 First Semester CO CEMS Report Stericycle, Inc. —Haw Raver Facility Haw River, Alamance County,North Carolina Air Permit No. 05896T22 Facility ID# 0100010 Dear Mr. Skrzypczak: Thank you for your timely submittal of the subject report, received July 31, 2014. The excess emissions report assessed the carbon monoxide (CO) continuous emissions monitoring systems (CEMS) operating at the Haw River Facility during the first half of 2014. The Division of Air Quality (DAQ) has completed its review and offers the following comments: 1. Hospital, medical and infectious waste incinerators(HMIWI) ES01 &ES02 were reviewed for compliance with a state-only CO emissions limit of 11 ppmvd(permit condition 2.LA.La) and a federal CO emissions standard of 40 ppmvd (permit condition 2.LA.1.h). Emissions were corrected to 7% 02 and calculated on a 12-hour rolling average. All excess emissions were attributed to either startup, shut down or malfunction. These emissions were reviewed and allowed in accordance with applicable emission rules. 2. Quarterly summary reports were reviewed for compliance with good operation and maintenance (O&M)practices pursuant to 40 CFR 60.11(d), General Condition 3.F and summarized as follows: Unit Quarter %EE %MD HMIWI ESO1 1st 0.6 0.33 2nd 1 0.0 0.44 HMIWI ES02 1st 0.0 0.00 2nd 0.0 0.11 The incinerators, along with associated CEMS units, appear to have operated using good O&M practices since quarterly percent excess emissions (%EE)and percent monitor downtime 1641 Mail Service Center,Raleigh,North Carolina 27699-1641 Phone:919-707-84001 Internet:www.ncdenr.gov An Equal Opportunity 1 Affirmative Action Employer—Made in part by recycled paper Mr. Alan Skrzypczak August 13, 2014 Page 2 (%MD) were less than 6% for any single calendar quarter and less than 3% for two consecutive quarters. 3. For both incinerators, CO CEMS cylinder gas audits (CGA) results were reviewed with respect to specifications set forth in Section 5 of 40 CFR Part 60, Appendix F. The quality assurance (QA)results appear to have met the 15% accuracy specification. If you should have any questions,please contact me at (919) 707-8493 or alan.drake@ncdenr.gov. Sincerely, Alan Drake Environmental Engineer cc: Michael Pjetraj, RCO Ray Stewart, WSRO Central Files, Alamance County IBEAM (0100010)