Loading...
HomeMy WebLinkAboutAQ_F_0100010_20151001_CEM_RptRvwLtr (4) North Carolina Department of Environmental Quality Pat McCrory Donald R. van der Vaart Governor Secretary October 1, 2015 Mr. Alan Skrzypczak Facility Manager Stericycle, Inc. Post Office Box 310 Haw River, North Carolina 27258 SUBJECT: Review of 2015 First Semester CO CEMS Report Stericycle, Inc. —Haw River Facility Haw River,Alamance County,North Carolina Air Pen-nit No. 05896T22 Facility ID# 0100010 Dear Mr. Skrzypczak: Thank you for your timely submittal of the subject report, dated July 23, 2015. The excess emissions report assessed the carbon monoxide (CO)/oxygen (02) continuous emissions monitoring systems (CEMS) operating at the Haw River Facility during the first half of 2015. We requested and received additional clarification from you via email concerning excess emissions of CO during startup. The Division of Air Quality(DAQ)has completed its review and offers the following comments: 1. Hospital, medical, and infectious waste incinerators (HMIWI) ESO1 & ES02 were reviewed for compliance with the state-only CO emissions limit of 11 parts per million by volume(ppmv, 7% 02, 12-hour rolling average) as stated in Air Pen-nit No. 05896, Specific Condition 2.1.A.La. Although there were no exceedances reported for ESO1 during this time period, there were nine (9) exceedances reported for ES02. All CO exceedances occurred during incinerator startup on January 11, 2015, with a maximum 12-hour average of 14.41 ppmv. The report indicated the startup for ES02 was extended [no waste was incinerated] until the elevated 12-hour CO average had cleared. Based on the above facts and the current permit monitoring condition, no further action will be taken. 2. Quarterly summary reports were reviewed for compliance with good operation and maintenance (O&M) practices pursuant to 15A NCAC 02D .0611(d), General Condition 3.F, and summarized as follows: Unit Quarter %EE %MD HMIWI ESO1 1st 0.0 0.1 2nd 0.0 0.0 1641 Mail Service Center,Raleigh,North Carolina 27699-1641 Phone:919-707-84001 Internet:www.ncdenr.gov An Equal Opportunity 1 Affirmative Action Employer-Made in part by recycled paper Mr. Alan Skrzypczak October 1,2015 Page 2 Unit Quarter %EE I %MD HMIWI ES02 1 st 0.5 0.2 2nd 0.0 0.0 The incinerators, along with associated CEMS units, appear to have operated using proper O&M practices since quarterly percent excess emissions (%EE) and percent monitor downtime (%MD) were less than 6% for any single calendar quarter and less than 3% for two consecutive quarters. If you should have any questions, please contact me at 919-707-8493 or alan.drake@ncdenr.gov. Sincerely, Alan Drake, Environmental Engineer Division of Air Quality,NCDEQ cc: Lisa Edwards, WSRO Michael Pjetraj, RCO Central Files, Alamance County IBEAM (0100010)