Loading...
HomeMy WebLinkAboutAQ_F_1900039_20141208_ST_ProtRvw A=&4*44A. NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary December 8, 2014 Chatham County Mr. Brian VanGelder Project Manager/Environmental Boise Cascade-Moncure Plywood 306 Corinth Road Moncure,NC 27559 Subject: Boise Cascade-Moncure Plywood, Moncure, Chatham County Air Permit No. 03424T23 Facility ID 1900039 Proposed Emissions Testing of 40-Panel Hot Press (ES-13-40HP) Proposed Test Date: December 10, 2014 Tracking No. 2014-233ST Dear Mr. VanGelder: DAQ has reviewed the proposed testing plan contained in the Protocol Submittal Form (PSF) for methanol, formaldehyde and VOC emissions from the 40-panel Hot Press. The applicable regulation is 40 CFR 63 Subpart DDDD (413)National Emissions Standards for Hazardous Air Pollutants:Plywood and Composite Wood Products. Emissions are uncontrolled for this source. A temporary total enclosure (TTE)will be constructed around the press to capture emissions and duct them to a sampling location. The PSF is acceptable as discussed below. The purpose for testing is to demonstrate compliance with 40 CFR 63 Subpart 4D. The subpart requires that the emissions meet one of the following requirements: 1. Reduce emissions from total HAP, measured as THC (Carbon)by 90 percent; or 2. Limit emissions of total HAP, measured as THC (as carbon) to 20 ppmvd; or 3. Reduce methanol emissions by 90 percent; or 4. Limit methanol emissions to < 1ppmvd if uncontrolled methanol emissions entering the control device are> 10 ppmvd; or 5. Reduce formaldehyde emissions by 90 percent; or 6. Limit formaldehyde emissions to < 1 ppmvd if uncontrolled formaldehyde emissions entering the control device are> 10 ppmvd. 1641 Mail Service Center,Raleigh,North Carolina 27699-1641 Phone:919-707-84001 Internet:www.ncdenr.gov An Equal Opportunity 1 Affirmative Action Employer—Made in part by recycled paper Mr. Brian VanGelder December 8, 2014 Page 2 Emissions measurement of formaldehyde and methanol will be conducted using NCASI Method 98.01. Total VOC will be measured using EPA Reference Method 25A. The capture efficiency of the TTE will be confirmed using Reference Method 204. DAQ approves the testing protocol and sampling procedures as specified in the PSF. Production data must be gathered during the testing period and included in the test report. If you have questions, please contact me at(919) 707-8413 or gary.saunders@ncdenngov, Sincerely, Gary L. Saunders Environmental Engineer cc: Patrick Butler, Raleigh Regional Office Central Files, Chatham County IBEAM Documents