HomeMy WebLinkAboutAQ_F_0100010_20160302_CEM_RptRvwLtr (3) PAT MCCRORY ;. Governor r- 0- DONALD R. VAN DER VAART Secretary AirQuafity SHEILA C. HOLMAN ENVIRONMENTAL QUALITY Director March 2, 2016 Mr. Alan Skrzypczak Facility Manager Stericycle, Inc. Post Office Box 310 Haw River, North Carolina 27258 SUBJECT: Review of 2015 Second Semester CO CEMS Report Stericycle, Inc. —Haw River Facility Haw River, Alamance County,North Carolina Air Permit No. 05896T22 Facility ID#0100010 Dear Mr. Skrzypczak: Thank you for your timely submittal of the subject report, received January 29, 2016. The excess emissions report assessed the carbon monoxide (CO)/oxygen(02) continuous emissions monitoring systems (CEMS) operating at the Haw River Facility during the second half of 2015. We requested and received additional clarification from you via email concerning excess emissions of CO during the third quarter. The Division of Air Quality(DAQ) has completed its review and offers the following comments: 1. Hospital, medical, and infectious waste incinerators (HMIWI) ES01 & ES02 were reviewed for compliance with the state-only CO emissions limit of 11 parts per million by volume (ppmv, 7% 02, 12-hour rolling average) as stated in Air Permit No. 05896, Specific Condition 2.1.A.l.a. There were no exceedances reported for ES01 during this time period; however, there were eleven (11) exceedances reported for ES02 during the third quarter. All CO exceedances occurred on July 6, 2015, with a maximum 12-hour average of 12.75 ppmv. It is our understanding the averaging time will be corrected to a 24-hour block average during the next permit revision. When the July 6, 2015 CO emissions were recalculated using the correct averaging time, the 24-hour block average was only 6.96 ppmv. Based on the above facts and the impending permit correction, no further action will be taken at this time. 2. Quarterly summary reports were reviewed for compliance with good operation and maintenance (O&M)practices pursuant to 15A NCAC 02D .0611(d), General Condition 31, and summarized as follows: Unit Quarter %EE %MD HMIWI ES01 3rd 0.0 0.0 4th 0.0 0.0 State of North Carolina I Environmental Quality I Air Quality 1641 Mail Service Center 1 217 W.Jones Street,Suite 4000 1 Raleigh,NC 27609-1641 919 707 8400 T Mr. Alan Skrzypczak March 2, 2016 Page 2 Unit Quarter %EE %MD HMIWI ES02 3rd 0.6 0.0 4th 0.0 0.0 The incinerators, along with associated CEMS units, appear to have operated using proper O&M practices since quarterly percent excess emissions (%EE) and percent monitor downtime (%MD)were less than 6% for any single calendar quarter and less than 3% for two consecutive quarters. If you should have any questions, please contact me at 919-707-8493 or alan.drake@ncdenr.gov. Sincerely, Alan Drake, Environmental Engineer Division of Air Quality, NCDEQ cc: Lisa Edwards, WSRO Michael Pjetraj, RCO Central Files, Alamance County IBEAM (0100010)