HomeMy WebLinkAboutAQ_F_1400008_20170619_ST_RvwMemo DIVISION OF AIR QUALITY
June 19,2017
MEMORANDUM
To: Brendan Davey,P.E. Asheville Regional Office
From: Shannon Vogel, Stationary Source Compliance Branc%�V LV
Subject: Bernhardt Furniture Company—Plants 2 & 5
Lenoir,Caldwell County,North Carolina
Facility ID 1400008,Permit No. 01755R22
Total Particulate Matter Emissions Testing of Emission Source ES-515
Performed November 15,2016 by Montrose Air Quality Services(MAQS)
Tracking No.2016-267st
MAQS performed EPA Method 5/202 and 9 to determine the total particulate matter(PM)and visible
emissions(VE)from Boiler ES-515 on November 15,2016. The test results are acceptable and
demonstrate compliance with the applicable emissions standards as discussed below.
Emissions Source ID ES-515 is wood waste/coal-fired boiler controlled by simple cyclone CD-203 and
bagfilter CD-219. The maximum permitted heat input rate is 25 million Btu per hour(mmBtu/hr). 15A
NCAC 2D .0503 Particulates From Fuel Burning Indirect Heat Exchangers limits PM to 0.43 pounds per
million Btu(lb/mmBtu)when firing coal and 15A NCAC 2D .0504 Particulates From Wood Burning
Indirect Heat Exchangers limits PM to 0.57 lb/mmBtu when firing wood. 15A NCAC 21) .0521 Control
of Visible Emissions applies and limits VE to 40%opacity. The test results tabulated below demonstrate
compliance with the applicable emissions standards.
Pollutant Test Results Emission Limit Standard Compliance
Filterable PM 0.385 lb/mmBtu --- --- ---
Condensible PM 0.003 lb/mmBtu --- --- ---
Total PM 0.388 lb/mmBtu 0.57 lb/mmBtu 2D .0504 Yes
Visible Emissions 7.10° 40% 2D .0521 Yes
Highest 6-min average
Heat Input Rate 19.5 mmBtu/hr 25 mmBtu/hr __-
Permitted maximum
The heat input rate during testing is acceptable. Compliance was demonstrated. If you have any
questions regarding the results of this review,please contact me at 919-707-8416 or
shannon.vo gel(&,ncdenr.gov.
cc: Central Files, Caldwell County
IBEAM Documents- 1400008