HomeMy WebLinkAboutAQ_F_1900104_20170207_CEM_RptRvwLtr ROY COOPER Governor MICHAEL S. REGAN Secretary Air Quality SHEILA C. HOLMAN Y Director ENVIRONMENTAL QUALITY February 7, 2017 Mr. Blake Arnett Plant Manager 3M Company- Pittsboro 4191 Highway 87 South Moncure,NC 27559 Subject: Review of Second Semester 2016 Continuous Opacity Monitoring Systems (COMS) Excess Emissions Report(EER) for ID No.ES1415, ESCPPHI &ESCPPH2-40 CFR Part 60,Subparts A and UUU; Facility ID No.1900104' Dear Mr.Arnett: The Division of Air Quality(DAQ) has reviewed the subject report, dated January 17, 2017. The report was reviewed for compliance with the monitoring and reporting requirements as well as compliance with the emission control standard (opacity limit)set forth in the current Air Quality Permit#09006T04. The report was also reviewed for compliance with good operation and maintenance (0&M) practices set forth in 40 CFR Subpart A,Section 60.11(d),60.13,and Subpart UUU. When the report was reviewed for compliance with the emission control standard (opacity limit),no opacity excursion was reported.Therefore,no violations appear to have occurred for any of the units. When the report was reviewed for compliance with the use of good 0&M practices,the following percent opacity excess emissions (%EE) and percent monitor downtime (% MD)were reported for each of the units: UNIT THIRD QUARTER 2016 FOURTH QUARTER 2016 C&S Dryer(ES 1415) % EE 0.0% % EE 0.0% % MD 0.96% % MD 1.31% COLOR Dryer(ESCPPHI) % EE 0.0% % EE 0.0% % MD 1.38% %MD 1.76% COLOR Dryer(ESCPPH2) % EE 0.0% %EE 0.0% %MD 2.15% % MD 2.74% DAQ considers sources to have operated with proper 0&M if%EE and/or%MD is less than the target criteria of 6.0%for any single quarter or less than 3.0%for any two consecutive quarters. The data shown above suggests that the facility and monitoring systems were operated using State of North Carolina I Environmental Quality I Air Quality 217 West Jones Street 1 1641 Mail Service Center I Melgh,North Carolina 27699-1641 919 707 8400 Mr. Blake Arnett February 7, 2017 Page 2 proper 0&M practices for minimizing emissions in accordance with 40 CFR Subpart A,Section 60.11(d),60.13,and Subpart UUU since the target criteria for making this assessment was not exceeded. The opacity audits were also reviewed with respect to Procedure 3 of 40 CFR Part 60, Appendix F.Based on the information provided,the quality assurance (QA)test results for the COMS operating at ESCPPHI, ESCPPH2 and C&S Dryers appear to have met the quarterly specifications. If you have any questions regarding this review,please call me at(919) 707-8410 or dennis.i bg oko.,,'&ncdenr.gov Sincerely, n Dennis U. Igboko,Environmental Engineer Division of Air Quality, NCDENR CC: Mike Pjetraj, RCO Patrick Butler- RRO Adam Driscoll- 3M Environmental Operations, 3M Center, Bldg 224-5W- 03,St Paul, MN 55144-1000 Central File-Chatham County IBEAM -Documents- 1900104