Loading...
HomeMy WebLinkAboutAQ_F_0400009_20170428_CMPL_RFI ROY COOPER Governor MICHAEL S. REGAN r10_ Secretary MICHAEL A. ABIZACZINSKAS Air Quality Director ENVIRONMENTAL QUALITY 28 April 2017 Charles Home, Owner Hornwood Inc. 766 Hailey's Ferry Road Lilesville,NC 28091 9759 F SUBJECT: Compliance Additional Information Requested: 15A NCAC 2D .0521 Control of Visible Emissions Hornwood Inc.., Air Permit No. 04888R14 Lilesville, Anson County,NC 06/0400099 Fee Class: Synthetic Minor Dear Mr. Horne: On 13 April 2017, Jeffrey Cole of the Fayetteville Regional Office, DAQ, met with Mr. Benny Burr, Environmental Manager and Mr. Dale Kelly, Plant Engineer, and conducted an air quality compliance inspection at your facility, Homwood Inc., in Lilesville, NC. (;;During the inspection, Mr. Cole observed that the emissions from your Condenser/Mist Eliminator (ID No. CD-2) appeared to be emitting greater than 20% opacity. Over an approximately 30 minute period on your roof, while speaking with your facility's Environmental Manager and Plant Engineer, they observed this emission source and discussed the questionable emissions. Mr. Cole asked your plant personnel to look into this operation and determine if all parts of this source were operating normal. As cited in your air permit, stipulation A.6, 15A NCAC 2D .0521 Control of Visible Emissions, "...visible emissions from the emission sources, manufactured after July 1, 1971, shall not be more than 20 percent opacity when averaged over a six-minute period, except that six-minute periods averaging not more than 87 percent opacity may occur not more than once in any hour nor more than four times in any 24-hour period." Please consult with your control device company's technical contacts concerning the proper operation and maintenance of both of your facility's Condenser/Mist Eliminators (ID Nos. CD-1 and CD-2)to ensure their performance is within permitted limits. Also,we encourage you to contact the NCDEQ's Division of Environmental Assistance and Customer Service (DEACS) at 1-877-623-6748 (ncenvironmentalassistance.org) for their technical help in improving your facility's environmental performance. i I I State of North Carolina I Environmental Quality I Air Quality Fayetteville Regional Office 1 225 Green Street,Suite 714 1 Fayetteville,North Carolina 28301 f 910 433 3300 T 1910 485 7467 F Hornwood Inc. 28 April 2017 Page 2 Please provide to this office as soon as possible, but no later than 26 May 2017, a written response detailing the reasons for the control device's apparent excessive opacity, and the steps (and timeline) that you plan to take or have taken to ensure both devices are complying with the above-mentioned permit requirement. The Fayetteville Regional Office, Division of Air Quality appreciates your prompt attention to this matter. If you have any questions regarding this matter please contact Jeffrey Cole, Environmental Engineer, or Heather Carter, Compliance Coordinator, at 910-433-3300. Si erely, 0 Steven F. Vozzo � U Regional Air Quality Supervisor NCDEQ, Division of Air Quality SFV/jdc cc: FRO Facility File f i l I State of North Carolina I Environmental Quality I Air Quality Fayetteville Regional Office 1 225 Green Street,Suite 7141 Fayetteville,North Carolina 28301 - 910 433 3300 T 1 910 485 7467 F