Loading...
HomeMy WebLinkAboutAQ_F_0100010_20170310_CEM_RptRvwLtr (3) ROY COOPER Governor MICHAEL S. REGAN Secretary Air Quality MICHAEL A. ABRACZINSKAS ENVIRONMENTAL QUALITY Acting Director March 10, 2017 Mr. Alan Skrzypczak Facility Manager Stericycle, Inc. Post Office Box 310 Haw River,North Carolina 27258 SUBJECT: Review of 2016 Second Semester CO/02 CEMS Report Stericycle, Inc. —Haw River Facility Haw River, Alamance County,North Carolina Air Permit No. 05896T25 Facility ID No. 0100010 Dear Mr. Skrzypczak: Thank you for your timely submittal of the subject report, received February 2, 2017. The excess emissions report assessed the carbon monoxide (CO)/oxygen(02) continuous emissions monitoring systems (CEMS) operating at the Haw River Facility during the second half of 2016. The CEMS was installed pursuant to 15A NCAC 02D .1206—Hospital, Medical, and Infectious Waste Incinerators. The Division of Air Quality(DAQ)has completed its review and has the following comments: 1. Hospital, medical, and infectious waste incinerators (HMIWI) ESO1 &ES02 were reviewed for compliance with the state-only CO emissions limit of 11 parts per million by volume (ppmv, 7% 02, 12-hour rolling average) as stated in Air Permit No. 05896, Specific Condition 2.1.A.La. There were no exceedances reported during this time period. 2. Quarterly summary reports were reviewed for compliance with good operation and maintenance (O&M)practices pursuant to 15A NCAC 02D .0611(d), General Condition 3.F, and summarized as follows: Unit Quarter %EE %MD HMIWI ESO1 3rd 0.0 0.0 4th 0.0 0.1 HMIWI ES02 3rd 0.0 0.0 4th 0.0 0.1 The incinerators, along with associated CEMS units, appear to have operated using proper O&M practices for minimizing emissions since quarterly percent excess emissions (%EE) State of North Carolina I Environmental Quality I Air Quality 1641 Mail Service Center 1 217 W.Jones Street,Suite 4000 1 Raleigh,NC 27609-1641 919 707 8400 T Mr. Alan Skrzypczak March 10, 2017 Page 2 and percent monitor downtime (%MD) were less than 6% for any single calendar quarter and less than 3% for two consecutive quarters. 3. Quarterly CO/02 CEMS cylinder gas audits (CGA)were reviewed for each incinerator. The quality assurance (QA)results appear to have met the 15% accuracy requirement of 40 CFR Part 60, Appendix F— Quality Assurance Procedures, referenced in Specific Condition 2.1.A.2.6i. If you should have any questions,please contact me at 919-707-8493 or alan.drake@ncdenr.gov. Sincerely, w sZ Alan Drake, Environmental Engineer Division of Air Quality,NCDEQ c: Lisa Edwards, WSRO Michael Pjetraj, RCO IBEAM Documents, 0100010 Central Files, Alamance County