Loading...
HomeMy WebLinkAboutAQ_F_1800419_20170203_ST_ProtRvw (4) ROY COOPER Governor MICHAEL S. REGAN Secretary Air Quality SHEILA C. HOLMAN ENVIRONMENTAL QUALITY Director February 3, 2017 Mr. Steve Linden,Plant Manager Prysmian Cables and Systems USA, LLC 2512 Penny Road Claremont,NC 28610-8634 Subject: Prysmian Cables and Systems USA,LLC,Facility ID 1800419, Tracking No.2017-045ST Claremont, Catawba County,North Carolina,Air Permit No. 07334T27 Protocol for Particulate Matter(PM),Hydrogen Chloride(HC1),Hydrogen Fluoride(HF), Chlorine (Cl), and Nitrogen Oxide(NO,,)Emissions Testing Proposed Test Date: The Week of February 20,2017, To be performed by Air-Tech Environmental, LLC Dear Mr. Linden: The emissions test protocol for the subject facility has been reviewed. Testing will be performed to meet the requirements in permit conditions 2.l.A.La,2.2.A.Lb, and 2.2.C.Ld. The test methods are acceptable to determine compliance with 15A NCAC 2D .0515 Particulates from Miscellaneous Industrial Processes and 15A NCAC 2Q .0317 Avoidance Conditions for 15A NCAC 2D .1111 Maximum Achievable Control Technology(MACT)and 15A NCAC 2D .0530 Prevention of Significant Deterioration (PSD)listed in the air permit. In order to avoid MACT applicability,the permit limits facility-wide individual hazardous air pollutants to less than 10 tons per consecutive 12-month period and combined hazardous air pollutants to 25 tons per consecutive 12-month period. To avoid PSD applicability,the permit limits NO,, emissions from all sources facility-wide to less than 250 tons per year. Testing will be performed at the wet scrubber outlet to determine the (PM/HCl,BF,and Cl)emissions. Testing will also be performed at the dry scrubber inlet to determine the NO,,emissions. The following table lists the pollutants and the test methods: Table 1: Pollutants and Test Methods - Sampling at Outlet of Wet scrubber 3WS EPA Methods/ Source ID No. Test Location Run Time Target Standard Emissions Limit Chemical vapor PM 15A NCAC 2D .0515 E=4.10 P0.67" deposition Units` Cell 5,6,7 (ES-1,ES-4-3WS, ES-14) 3 runs HCl 15A NCAC 2Q .0317 Facility-wide Chemical room 5/26A 60 minutes each HF,� MACT Avoidance of < 10 tons/yr each (ES-11) Cl 15A NCAC 2D .I I 11 and <25 tons/ combined SiCL4 bulk storage Y1 room (ES-18) ' Note:According to the protocol submittal only 2 units are operating and only 2 will be operating in 2016. " For P<30 tons/hr: Allowable emissions limit E(lb/hr),Proccess weight P(tons/hr) Note audit samples analysis is required for EPA Method 26A. During the test period the audit sample must be present for inspection on request. For additional information please see EPA web page http://www.ppa.;;ov/emc/emc-technical-support. State of North Carolina I Environmental Quality I Air Quality 217 W.Jones Street 11641 Mail Service Center I Raleigh,North Carolina 27699-1641 919 707 8400 Mr. Steve Linden,Plant Manager February 3, 2017 Page 2 Table 2: Pollutants and Test Methods - Sampling at Inlet of H drated lime injection fabric filter 2DS EPA Methods/ Source ID No. I Test Location Run Time I Target Standard Emissions Limit 15A NCAC 2Q .0317 7E** 3 runs, NO, PSD Avoidance of <250 tons/yr 60 minutes each Over-cladding 15A NCAC 2D .0530 Units*Cell 5,6,7 1-4 3 runs, Flow Rate, --- -- (ES-9a) (With Method 7E) 30 minutes each Moisture 205 _ Calibration (For Method 7E) Gas Dilution * Note: According to the protocol submittal only 2 units are operating and only 2 will be operating in 2016. *' The tester must conduct a stratification test as described in Section 8.1.2 of EPA Method 7E to determine the NO,,sampling traverse points/point to be used. The test protocol is approved. The tester must verify the absence of cyclonic flow as described in Section 11.4 of EPA Method 1. Please note that when using EPA Methods 26A the limits of detection are based on actual source parameters. There are no estimated detection limits in the test protocol. Therefore, the responsibility will remain with Prysmian Cables and Systems USA and Air-Tech Environmental to insure that the minimum detection limits are low enough to demonstrate compliance with the applicable emissions limits. The result cannot be reported as zero. The result must be reported as less than the method detection limit determined from the test. The EPA Method 205 Verification of Gas Dilution Systems for Field Instrument Calibrations testing must be performed prior to beginning the test. The dilution ratios to be used during the test period shall be verified during the Method 205 procedure. The test data may be rejected if Method 205 is not performed appropriately. Also the request to assign dry ambient air a molecular weight of 29.0 is approved provided the tester documents the reasons the default value is appropriate. Prysmian Cables and Systems USA shall be responsible for ensuring, within the limits of practicality,that the subject facility being tested is operated at maximum normal operating conditions. The target process rate is 0.0024 tons per hour. The final report must include information documenting the test period production target rate and the permit required emissions factors for monitoring, recordkeeping and reporting. The wet scrubber operating parameters during testing must also be included with the report (i.e., pressure drop, liquid flow rate,pH,make up liquid rate). Approval of the proposed testing methods does not exempt the tester,in any way, from the minimum requirements of the applicable test methods. Any deviations from the applicable methodologies not specifically addressed in this letter remain subject to the approval of the Division of Air Quality. If there are questions concerning this matter,please contact me at(919) 707-8415 or gregg.onealLwncdenngov.. Sincerely, Thomas G. ONeal,I11,P.E., Environmental Engineer Division of Air Quality,NCDEQ cc: Rick Miller,Prysmian Cables and Systems USA,LLC -Claremont,NC Mike Hartman/Darrell Doerie, Air-Tech Environmental, LLC -Durham,NC Bruce Ingle,Mooresville Regional Office Central Files,Catawba County IBEAM Documents - 1800419