HomeMy WebLinkAboutAQ_F_1400008_20161101_ST_ProtRvw (4) PAT MCCRORY
Governor
DONALD R. VAN DER VAART
seeretary
Air Quality SHEILA C. HOLMAN
ENVIRONMENTAL QUALITY Director
November 1, 2016
Mr. Eddie Pitts
Corporate Environmental Manager
Bernhardt Furniture Company
1828 Morganton Boulevard
Lenoir,North Carolina 28645
Subject: Bernhardt Furniture Company—Plants 2&5
Lenoir, Caldwell County,North Carolina
Facility ID 1400008, Permit No. 01755R22
Total Particulate Matter and Visible Emissions Test Protocol for ES-515 Boiler
Submitted by Montrose Air Quality Services
Proposed Test Date: November 16, 2016
Tracking No. 2016-267st
Dear Mr. Pitts:
The North Carolina Division of Air Quality has reviewed the protocol for the particulate matter(PM) and
visible emissions(VE)testing of boiler ES-515. The proposed test methods and operating conditions are
acceptable for the compliance testing as discussed below.
Emission Source ES-515 is a wood waste/coal-fired boiler with no flyash reinjection controlled by
multicyclone CD-515. The maximum permitted heat input rate is 25 million Btu per hour. 15A NCAC
2D .0504 Particulates From Wood Burning Indirect Heat Exchangers and 15A NCAC 2D .0521 Control
of Visible Emissions apply. 15A NCAC 2D .0504 limits PM for wood firing to 0.57 pounds per million
Btu and 15A NCAC 2D .0521 limits VE to 40%opacity.
Montrose has proposed EPA Method 5/202 for total particulate matter and EPA Method 9 for visible
emissions. EPA Methods 1, 2, 3A and 4 are also proposed in support of the EPA Method 5/202 PM
sampling. The proposed operating rate is 90%of normal operating load. The protocol submittal form
indicates that the fuel usage will be monitored and reported in terms of pounds per minute of wood
burned. The proposed methods are acceptable.
Approval of this sampling protocol does not exempt the tester from the minimum requirements of the test
methods. Any deviations remain subject to approval by DAQ. If you have any questions,please contact
me at 919-707-8416 or shannon.vogel@ncdenr.gov.
Sincerely,
4
Shannon Vogel, Environm al Engineer
Division of Air Quality,NC DEQ
cc: Central Files,Caldwell County Brendan Davey, Asheville Regional Office
Kent Childers,Montrose Air Quality Services IBEAM Document - 1400008
State of North Carolina I Environmental Quality I Air Quality
1641 Mail Service Center 1 217 W.Jones Street.Suite 4000 1 Raleigh,NC 27699-1641
919 707 8400 T