Loading...
HomeMy WebLinkAboutAQ_F_1600120_20161220_CMPL_InspRpt NORTH CAROLINA DIVISION OF Wilmington Regional Office AIR QUALITY Parker Marine Enterprises Inc NC Facility ID 1600120 Inspection Report County/FIPS: Carteret/031 Date: 12/22/2016 Facility Data Permit Data Parker Marine Enterprises Inc Permit 06848/T09 2570 Highway 101 Issued 2/25/2015 Beaufort,NC 28516 Expires 1/30/2020 Lat: 34d 48.6580m Long: 76d 40.3280m Classification Title V SIC: 3732/Boat Building And Repairing Permit Status Active NAILS: 336612/Boat Building Current Permit Application(s)None Contact Data Program Applicability Facility Contact Authorized Contact Technical Contact SIP/Title V Eric Denton Lynwood Parker III Eric Denton MACT Part 63: Subpart VVVV Engineering Technician President Engineering Technician 252-728-5621 252-728-5621 252-728-5621 Comments: l tb Compliance Data Inspection Date 12/20/2016 Inspector's Signature: Inspector's Name Ashby Armistead Operating Status Operating Compliance Code Compliance-inspection Action Code ICE Date of Signature: 12/22/16 On-Site Inspection Result Compliance Total Actual emissions in TONS/YEAR: TSP SO2 NOX VOC CO PM10 * HAP 2015 --- --- --- 15.78 --- --- 28818.31 2014 --- --- 12.03 --- --- 21957.53 2013 --- 10.96 --- --- 20065.65 * Highest HAP Emitted(inpounds) Five Year Violation History: None Date Letter Type Rule Violated Performed Stack Tests since last FCE: None Date Test Results Test Method(s) Source(s)Tested General Facility Summary The facility can be reached by taking Highway 70 through Morehead City and into Beaufort. Follow Hwy. 70 through Beaufort. On the far side veer left to take Hwy. 101 N. The facility is located approximately 6 miles up Hwy. 101 on the right. A BP station is across from it. To get to the office, take a right onto Laurel. The first driveway on the left is the parking lot. Safety boots and glasses are required. Parker manufactures 18 to 34 foot center console/cabin sport fishing boats. Many different configurations are available. They introduced a 34 ft cabin boat in 2008. I Currently Permitted Sources Emission Emission Source Description Control Control Device Source ID Device ID Description No, No. i Building No. Laminating, gel coating, and DF Dry filters 1 assembly (110,500 sq. ft. of (MALT, production area) Subpart VVVV) i i The equipment list for boat manufacturers is intentionally vague. It gives the facility more production flexibility by allowing them to move equipment and add or remove lamination guns as needed without going through a permit modification. j i Inspection Results The facility expanded their production area with the addition of a 39,000 ft2 building. The facility modeled styrene emissions to demonstrate compliance with toxics. The new permit was issued by RCO before the modeling was completed. A condition [Section 2.2(3)] (T04)was placed in the permit requiring a demonstration of compliance for styrene within 90 days of permit issuance. The original modeling request was sent to AQAB in September 2000. After revisions on March 16 and March 28, 2001, the modeling was approved by AQAB on April 3, 2001. Two different production scenarios were modeled, a temporary one in which all VOC emissions exit through the lamination stacks, and the normal operating configuration in which emissions from lamination exit through the lamination stacks and gel coat emissions exit the gel coat booth stacks. The worst case was the normal operation, in which styrene emissions would be 93% of the 1 hour AAL. In both cases,the stacks had to be raised to achieve compliance. The two lamination stacks by—15 ft to 45 ft above ground level (agl), and the gel coat booth one by—15 ft to 40 ft agl. All the stacks have been raised and the facility is operating under the normal configuration. I was accompanied during the inspection by Mr. Denton. The newer building is attached to the old building and can be isolated by large doors. All lamination is done in the newer building. Nine lamination of resin guns on booms were installed at the time of inspection. Three were operating. These are the "flow coater" guns. The portable gun was not being used. The foam gun on the small boom was not being used. There are 22 filters down the left side of the building. There are 20 on the right side. Each side is vented via external ductwork to its own stack. The filters looked ok but a couple were sagging due to missing retainer rods. Eric said they would fix them asap. No problems were noted with the ductwork. The opacity was 0% from each stack. i The gel coat booth(2 guns) was not moved to the new building as originally planned. Instead it was moved against the shared wall between buildings. As a result, Parker had to remodel their normal operating scenario. Compliance was indicated, though the stack had to be raised. The second gel coat booth, which has not been installed, was also remodeled. The plan at the time of remodeling was to also put it on the shared wall, on the other side of the bay door. The relocation of the existing booth began around the end of May of 2001, the booth resumed operation during the first week of September according to Mr. Harrison(former employee). During that time, all gel coating was done in the new building, as modeled in the temporary scenario. The booth was operating during the inspection. The 34 filters were ok. The grinding booth is installed in the old building. The booth draws air through the back wall into a room containing 18 cylindrical filters. The air travels through the two banks of filters and is exhausted over the top of the booth back into the plant via ductwork. The front of the booth is separated from the plant by vertical sections of suspended clear plastic. Grinding was being done. The filters are cleaned by air pulses and looked ok. The photohelic gauge read 3.5 inches of H2O on the left bank. The current AP range is 1.5 — 3.5. The right bank was not operating. A water mist j system was added to comply with OSHA's explosion risk requirements. The facility is keeping a record of their weekly filter inspections as required. No problems were noted in the records for the period of June of 2016 through 12/13/16. 'I All observed containers were covered, and the facility is keeping a monthly inspection log as required by 2D .0958. No problems were noted in the records reviewed for the period of June of 2016 through 12/15/16. This also satisfies their MACT work practices requirement (63.5731). The facility is tracking VOC usage as required to stay below their PSD avoidance limit of 250 tons per year. No problems were seen in the records for the period since the last inspection through November of 2016. The November VOC emission total for the previous 12 months is 18.4 tons. Parker has off-white, yellow, sage green, tan, light and dark blue gel coats. They have different VOC contents, and Parker uses the highest value for all gel coats in their calculations. Parker submitted their semi-annual report for the first half of 2016. It covers PSD avoidance and the filter and work practices inspections. No problems were noted. The facility had additional monitoring and quarterly reporting for toxics due to styrene and MEK limits. Resin, gel coat, and catalyst usage were tracked on a daily basis. The NC toxics conditions and quarterly reporting requirements were removed with issuance of T09. Those VOC sources are covered by the Boat MACT. Under the averaging option for the Boat MACT, HAP emissions are compared to a calculated limit on a monthly basis and reported on a semi-annual basis. Parker submitted their initial report (Implementation Plan) on 09/21/05. The semi-annual report for the first half of 2016 was submitted. Parker is using EPA"approved" software to track compliance. No emission limits have been exceeded based on the data through November of 2016. They are keeping the required product usage records. Parker cleans their equipment with acetone which is not classified as a HAP. Compliance with 63.5734 is indicated. ! I 63.5740 requires that carpet and adhesive fabric glue contain no more than 5% organic HAP. Parker uses a water-based glue so compliance is indicated. I Compliance History The facility was assessed a$1,000 civil penalty on 07/21/05 for failing to submit their 2004 emissions inventory by 06/30/05. The inventory was submitted on July 12'h. Parker also submitted a request for remission which was denied by the EMC. The facility was issued a NOV on 08/28/02 for submitting a semi-annual report late. No problems were contained in the report itself. Permit Revisions T09 was a renewal. The 2D .1100 condition was removed. Several Boat MACT conditions that don't apply to this facility were also removed. SSM language was added since Subpart VVVV doesn't address it and the SSM exemption rules were vacated. T08 was a renewal. T07 was an administrative amendment to correct a date. T06 was a renewal. Conclusions, Comments, and Recommendations The regulation table in Section 2.LA of the permit still list 2D .1100 as being applicable. This should be removed during the next permit revision. Parker does not have any emergency generators. No stack testing has been performed at this facility in at least 14 years. The facility has two 6,000 gallon resin tanks that were previously determined to be exempt from permitting. They are considered part of the laminating process and were included in the modeling. The facility added a 213 x 35ft section to the old building in 2002. It is used for storage. The woodworking operation moved in there as well. The woodworking operation is not permitted, it exhausts inside. No lamination or gel coating is done in there. A ventilation system for worker comfort is installed in the old building. The system exhausts through a stack on the roof. No lamination is done in this building. Mr. Peffer(former employee) submitted a permit exemption request to RCO in June of 2003. Parker wanted to exhaust the new grinding booth outside in the summer to keep the plant cooler. The booth was determined by RCO Permits to be an insignificant source. As of this inspection, Parker had not altered the booth to vent outside. In their 2007 emissions inventory, Parker began using the Unified Emission Factors for open molding of composites published on 07/23/01. Boat manufactures were instructed to start using these factors. Parker was using factors from the study published in August of 1997 for the National Marine Manufacturers Association. The Unified Emission Factors appear to have lowered Parker's estimated emissions. The facility appeared to be operating in compliance with their air permit at the time of the ! inspection.