Loading...
HomeMy WebLinkAboutAQ_F_1900104_20170728_CEM_RptRvwLtr ROY COOPER Governor MICHAEL S. REGAN N. Set retan, Air Quality ENVIRONMENTAL QUALITY MICHAEL A. ABRACZINSKAS 1)hccvor July 28,2017 Mr.Blake Arnett Plant Manager 3M Company-Pittsboro 4191 Highway 87 South Moncure,NC 27559 Subject: Review of First Semester 2016 Continuous Opacity Monitoring Systems(COMS)Excess Emissions Report(EER) for ID No. ES1415,ESCPPHI &ESCPPH2-40 CFR Part 60, Subparts A and UUU; Facility ID No.1900104 Dear Mr.Arnett: The Division of Air Quality(DAQ)has reviewed the subject report,dated July 18, 2017. The report was reviewed for compliance with the monitoring and reporting requirements as well as compliance with the emission control standard(opacity limit) set forth in the current Air Quality Permit# 09006T04. The report was also reviewed for compliance with good operation and maintenance(O&M) practices set forth in 40 CFR Subpart A, Section 60.11(d), 60.13,and Subpart UUU. When the report was reviewed for compliance with the emission control standard(opacity limit), no opacity excursion was reported. Therefore,no violations appear to have occurred for any of the units. When the report was reviewed for compliance with the use of good O&M practices,the following percent opacity excess emissions(%EE)and percent monitor downtime(%MD)were reported for each of the units: UNIT FIRST QUARTER 2017 SECOND QUARTER 2017 C&S Dryer(ES 1415) %EE 0.0% %EE 0.0% %MD 0.73% %MD 0.85% COLOR Dryer(ESCPPHI) %EE 0.0% %EE 0.0% %MD 0.88% %MD 1.37% COLOR Dryer(ESCPPH2) %EE 0.0% %EE 0.0% %MD 1.62% %MD 1.10% DAQ considers sources to have operated with proper O&M if%EE and/or%MD is less than the target criteria of 6.0% for any single quarter or less than 3.0%for any two consecutive quarters.The data shown above suggests that the facility and monitoring systems were operated using proper O&M practices for minimizing emissions in accordance with 40 CFR Subpart A, Section 60.11(d), 60.13,and Subpart UUU since the target criteria for making this assessment was not exceeded. The opacity audits were also reviewed with respect to Procedure 3 of 40 CFR Part 60,Appendix F.Based on the information provided,the quality assurance(QA)test results for the COMS operating at ESCPPHI,ESCPPH2 and C&S Dryers appear to have met the quarterly specifications. State of North Carolina I Environmental Quality I Air Quality 1641 Mail Service Center 1 217 W.Jones Street,Suite 4000 1 Raleigh,NC 27609-1641 919 707 8400 T i. Mr.Blake Arnett July 28, 2017 Page 2 If you have any questions regarding this review,please call me at(919)707-8410 or dennis.i gbokoiu nedenr. gov Sincerely, v' rntal . Dennis U. IX ko,Environm Engineer Division of Air Quality,NCDENR CC: Donald R. van der Vaart, Ph.D.,J.D., P.E., Chief- RCO Patrick Butler—RRO Adam Driscoll—3M Environmental Operations, 3M Center,Bldg 224-5W—03, St Paul,MN 55144-1000 Central File-Chatham County IBEAM—Documents— 1900104