HomeMy WebLinkAboutAQ_F_2100073_20180911_ST_ProtRvw (4) =r s' 14. ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary MIC14AEL ABRACZINSKAS Director September 11,2018 Michael Aust Manager Environmental,Health and Safety Regulator Marine, Inc. 187 Peanut Drive Edenton,NC 27932 Subject: Regulator Marine, Inc. Edenton, Chowan County,North Carolina Facility ID 21-00073,Air Permit No. 07132T1 I Proposed Carbon Monoxide(CO)Emissions Testing of Diesel-Fired Peak Shaving Generator ES-I4 by Integrity Air Monitoring,Inc. October 25,2018 DAQ Tracking No. 2018-275ST Dear Mr.Aust: The North Carolina Division of Air Quality(DAQ)has reviewed the protocol submittal form(PSF)for CO emissions testing of generator ES-I4. Integrity Air Monitoring proposes EPA Method 3A for oxygen(02) and EPA Method 10 for CO emissions testing. The proposed methods are acceptable for demonstrating compliance with the applicable regulations. ES-I4 is a diesel-fired peak shaving generator controlled by diesel oxidation catalyst CD-I4. The generator is rated at 764 horsepower maximum capacity. 40 CFR 63 Subpart ZZZZ National Emissions Standards for Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines applies and specifies CO emissions shall be reduced by 70%or more using an oxidation catalyst. Permit condition 2.1.C.3 states the temperature of the catalyst inlet should be maintained at >_450 OF and< 1350 OF. The pressure drop across the catalyst should be maintained f 2 inches of water from the pressure drop that was measured during the most recent performance test with the engine operating at±10%of full load. Integrity proposes testing at the inlet and outlet of the catalyst with the differential pressure across the catalyst and temperatures being measured every minute and engine output being measured and recorded every 5 minutes. The CO and 02 measurements should be dry and the engine should be tested at±10%of maximum load. rroa'mcaaouragR`E Q_ o�rtmia�xr� r North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh,North Carolina 27699-1641 919.707.8400 Mr.Michael Aust Page 2 DAQ Tracking No. 2018-275ST The proposed testing is acceptable for demonstrating compliance with the regulations. Approval of the protocol does not exempt the tester from the minimum requirements of the methods. Deviation from the methods remains subject to approval by DAQ. If there are any questions regarding this review,please contact me at(919)707-8427 or Brent.Hall@ncdenr.gov. Sincerely, 944��� Brent W.Hall Environmental Engineer Cc: Andrew Dickson, Integrity Robert Fisher,WARO Central Files, Chowan County IBEAM Documents-2100073