Loading...
HomeMy WebLinkAboutAQ_F_0400056_20190426_ST_ProtRvw ROY COOPER NORTH CAROLINA Governor Environmental Quality MICHAEL S.REGAN Secretary MICHAEL ABRACZINSKAS Director April 26, 2019 Ms.Macrae Walters Sr. Environmental Specialist Piedmont Natural Gas 526 South Church Street(EC 12J) Charlotte,NC 28202-1802 Subject: Piedmont Natural Gas,Inc. -Wadesboro Compressor Station Wadesboro,Anson County,North Carolina,Air Permit No. 10097TO1 Protocol for Nitrogen Oxides, Carbon Monoxide,Volatile Organic Compounds Emissions Testing Emergency Generator(ID No. EGO1) To Be Performed Week of May 6,2019 by Mostardi Platt Facility ID 0400056,Tracking No. 2019-093ST Dear Ms.Walters: The North Carolina Division of Air Quality(DAQ)has reviewed the subject protocol submittal form for the emissions testing of EGO1. The proposed testing is acceptable to demonstrate emissions compliance. The table lists the proposed test methods and emissions limits. EGO1 is a 804 horsepower(BP) four-stroke lean burn natural gas-fired emergency generator. The emissions from EGO1 are uncontrolled. EGO1 is subject to 40 CFR 63 Subpart ZZZZ National Emission Standards for Hazardous Air Pollutants for Reciprocating Internal Combustion Engines(RICE)which requires that the facility comply with 40 CFR 60 Subpart JJJJ Standards of Performance for Stationary Spark Ignition Internal Combustion Engines. Target EPA Method Run Time Standard Emission Limit Volumetric Flow Rate 1 and 2 3 runs,60 minutes each --- Concurrent with(320) Molecular Weight 3A 3 runs,60 minutes each ___ ___ Oxygen Concurrent with(320) Moisture Content --- Nitrogen Oxides 2.0 g/HP-hr (NOX) 60 Subpart JJJJ (or 160 ppmvd@15%02) Carbon Monoxide 320 3 runs,60 minutes each 60 Subpart JJJJ 4.0 gd P-hr 0 (CO) (or 540 ppmvd@15 0 02) Volatile Organic Compounds 1.0 g/HP-hr (VOC*) 60 Subpart JJJJ (or 86 ppmvd(&15%02) *VOC as non-methane organic compounds as propane Q4MOC as C3H8). D_E Q nbrarN��r wn � r�� North Carolina Department of Environmental Quality I Division of Air Quality 217 West Jones Street 1 1641 Mail Service Center I Raleigh,North Carolina 27699-1641 919.707.8400 Ms.Macrae Walters, Sr. Environmental Specialist April 26,2019 Page 2(Piedmont Natural Gas-Testing Generator ESO1 for NOx, CO, and VOC Emissions) Prior to sampling,the EPA Method 7E Section 8.1.2 stratification test must be performed to determine the sampling points. VOC means non-methane organic compounds(NMOC)as defined in 40 CFR 51.100(s). Note that 40 CFR 60 Subpart JJJJ requires testing to be conducted every 8,760 hours of operation or every three years,whichever comes first. Approval of this protocol does not exempt the tester or Piedmont Natural Gas from the minimum requirements of the sampling methods and applicable regulations. Any deviations remain subject to approval by DAQ. The proposed operating rate for testing is greater than 90%maximum normal. The proposed rate meets the 40 CFR 60 Subpart JJJJ requirement to perform testing within 10%of peak load (or maximum achievable load). The report must include the test period process rate and associated monitoring parameters (i.e.engine speed,power output levels, fuel flow, fuel pressure,air intake data and operating temperatures). If there are any questions concerning this matter,please contact me at(919)707-8415 or gre ag.oneal(a,ncdenr.gov. Sincerely, s� Thomas G. ONeal,1I1,P.E.,Environmental Engineer Division of Air Quality,NCDEQ cc: David Ozawa,Mostardi Platt-Elmhurst,IL Heather Carter,Fayetteville Regional Office Central Files,Anson County ]]BEAM Documents-0400056