Loading...
HomeMy WebLinkAboutDEQp00021247(Guideline limitations, if applicable, are to be listed on the back of this form.) Design Tbmp.: Drainage Area (mi 2)= Avg, Streamflow (cfs): 7Q10 (cfs) /1. C.,� X ) Winter 7Q10 (cfs) 30Q2 (cfs) Location of D.O. minimum (miles below outfall): Slope (fpm) Velocity ( fps) : Kl (base e, per day): K2 (base e. per day): Ori' cation 0 Comments: frlpw Zmc taa6a *ftm 0•5 Wvb '1-o I.I #46D R s Allocation G irmata.on O Reviewed By: Date: Prepared By: NIDES WASTE LOAD ALLOCATIONineer f Date Rec . ;1 -tc,A-M-1612-010 Facility. Name:. �. " Date Existing Proposed O Permit No.: Ne' 006MM , Pipe No.: GO t County: Q Design Capacity (MGD) : +: Industrial (% of Flow) : too Domestic (% of Flow) : �---� Receiving Stream: CAVOL RUMA Class: I ■ Sub -Basin : ® Sorg iia Reference USGS Quad: (Please attach) Requestor: 14" Fi a Regional, Office. a (Guideline limitations, if applicable, are to be listed on the back of this form.) Design Tbmp.: Drainage Area (mi 2)= Avg, Streamflow (cfs): 7Q10 (cfs) /1. C.,� X ) Winter 7Q10 (cfs) 30Q2 (cfs) Location of D.O. minimum (miles below outfall): Slope (fpm) Velocity ( fps) : Kl (base e, per day): K2 (base e. per day): Ori' cation 0 Comments: frlpw Zmc taa6a *ftm 0•5 Wvb '1-o I.I #46D R s Allocation G irmata.on O Reviewed By: Date: Prepared By: For AppWiate .Dischargers, List Complete Guideline Limitations Below Effluent Monthly Maximum Daily Characteristics Average Average Cbmments Type of Product Produced I Lbs/Day Produced f Effflierit Guideline Reference I Reauest NA. . 7-040 --------------------- WASTELOAD ALLOCATION APPROVAL. FORM ----------------------- 4 Facilitw Name # E.I. DUPONT--FAYETTEVTL.LE PLANT Twpe Of Waste INDUSTRIAL -1 Receiving Stream CAPE FEAR RIVER (7 Stream Class Cgs Subbasin 030616 1AJ AN 28 198 Countw BLADEN Regional Office FAYETTEVILLE Reauestor DOUG FINAN ENV. MANAGEMENT Drainage Area (so mi) FAYETTEVILLE REG. OFFICE 7010 (cfs) 700 Winter 7010 (cfs) 3002 (cfs) ------------------------- RECOMMENDED EFFLUENT LIMITS -------------------------- �ar►ly Marc Wasteflow (mg 14.1 "Al # 259 359 5-Dav BOB (14 PH (SU) 6-9 TSS (11*/d) 209 350 — -------------------------------- COMMENTS ----------------------------------- LIMITS ARE SAME AS THOSE PREVIOUSLY ASSIGNED WITH THE EXCEPTION OF WASTEFLOW WHICH INCREASED FROM 0*5 TO 1*1 MOD, FACILITY IS PROPOSED ( ) EXISTING (*) NEW ( ) LIMITS ARE REVISION 04.) CONFIRMATION ( ) OF THOSE PREVIOUSLY ISSUED RECOMMENDED BY#* DATE: REVIEWED BY1# -C'5 SUPERVISORY TECH. SUPPORT -,DATE REGIONAL SUPERVISOR Approval is Preliminary final PERMITS MANAGER ?OZ18 DIVISION OF ENVIRONMENTAL MANAGEMENT January 16, 1985 MEMORANDUM TO Trevor Clements FROM . Doug Finan !7)- SUBJECT: WLA for E.I. DuPont De Nemours & Company, Inc. Please find attached a request by Dupont to increase the flow on pipe #001. Because the facility has production based limits, the total pounds of BOD should not increase. However, please review the WLA for this facility to confirm that problems should not arise from this change. A -NE TEC"NaL SERVICES UR11 Res.: (919)485-1412 THOMAS W. OLCOTT Environmental Control Coordinator Senior Chemist E. I. DU PONT DE NEMOURS & COMPANY (INC.) Polymer Products Department Manufacturing Division Fayetteville Works P.O. Drawer Z Fayetteville, NC 28302 (919) 483-4680 Z-544 REV. 12-79 _ oUPONT ESTABLISHED 1802 E. I. DU PONT DE NEMOURS & COMPANY INCORPORATED P. O. DRAWER Z FAYETTEVILLE, N. C. 28302 POLYMER PRODUCTS DEPARTMENT December 18, 1984 Douglas S. Finan, Acting Supervisor NPDES Permits Group • North Carolina Department of Natural Resources and Community Development P.O. Box 27687 Raleigh, North Carolina 27611-7687 Dear Mr. Finan: Thank you for your letter of December 10. I apologize for making an inappropriate assumption that you had detailed data on our biofacilities at your fingertips. As we discussed by telephone yesterday, the data you requested are given below: Aeration Basin Effective Volume - 440,000 gallons Clarifier Effective Surface Area - 1590 ft.2 Fayetteville Flow., Million gal. GLUMRB Standard* 0.5 1_1 Aeration Detention, hrs. 21.1 9.6 6.0 - 7.5 Clarifier Overflow (gpd/ft.2) 314 692 700 * Great Lakes - Upper Mississippi River Board of State Sanitary Engineers, Recommended Standards for Sewage Works, 1971. The values reported above are for plants in the flow range of 0.5 million gpd to 1.5 million gpd. R CEIVE ► � E, 1 91984 NATER QUALIFY Y SECTION OPERATIONS BRANCH There's a world of things we're doing something about �•q _ ter': .� r DOUGLAS S. FINAN -2- DECEMBER 18, 1984 The recommended standards are based on peak flow (for "significant flow periods", i -.e. maximum daily) rather than average values. Maximum daily flow is a more appropriate design parameter than average flow. We still maintain that flow limits are unnecessary for an effluent limited discharge because exceeding the hydraulic or oxidative capacity of the plant will result in exceeding the mass -based discharge limits. However if the Department feels a flow limitation is required, only a daily maximum value, rather than daily average value, need be imposed to.conform to recommended standard practice. If you need any further information or clarification on this subject, please contact me. Sincerely, Thomas W. Olcott Environmental Control Coordinator (919) 483-4581 TWO:mm 0882M CC: M.J. Noland Regional Supervisor