HomeMy WebLinkAboutDEQp00022668North Carolina Department of Environmental Quality Pat McCrory Governor September 28, 2015 Michael E Johnson The Chemours Company Fc LLC 22828 NC Highway 87 West Fayetteville, NC 283067332 SUBJECT: 9/16/2015 Compliance Evaluation Inspection The Chemours Company Fc LLC Chemours Company -Fayetteville Works Permit No: NC0003573 Bladen County Dear Mr.Johnson: Donald R. van der Vaart Secretary RECEIVED SEP 3 0 2015 CENTRAL FILES DWR SECTION Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on 9/16/2015. The Compliance Evaluation Inspection was conducted by Mark Brantley, Environmental Senior Specialist, of the Fayetteville Regional Office. The facility was found to be in Compliance with permit NC0003573. The cooperation of Jamie Lewis, Grade 4 facility ORC, was greatly appreciated. As a reminder, preservation of the Waters of the State can only be achieved through consistent NPDES Permit compliance. Comments • Facility was clean and neat in appearance at the time of the inspection. • Maintenance records are maintained on an electronic work order system. • ORC logbooks are well kept. Laboratory records for the month of February 2015 were compared to the monthly DMR and no transcription errors were found at that time. • Facility's NPDES permit will expire on October 31, 2016. Please remember that the permit renewal application is to be submitted at least 180 days prior to the expirations date. • Enclosed is a registration form for the Division of Water Resources eDMR program. Once the facility is registered staff from the Fayetteville Regional Office will conduct a technical help session for Chemours Staff. Fayetteville Regional Office 225 Green Street, Suite 714, Fayetteville, North Carolina 28301-5095 Main Phone: 910-433-3300 \ Internet: hftp://www.ncdenr.gov An Equal Opportunity \ Affirmative Action Employer — Made in part by Recycled Paper Mr. Johnson Page 2 September 28, 2015 Please refer to the enclosed inspection report for additional observations and comments. If you or your staff have any questions, please call me at 910-433-3327. Sincerely, Mark Brantley Environmental Senior Specialist Division of Water Resources Water Quality Regional Operations Section cc: Jamie Ray Lewis, ORC Central Files Fayetteville Files (kmb) United States Environmental Protection Agency Forth Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NC0003573 111 12 15/09/16 117 18 I S I 19 I c 1 20 LJ 2111111[ IIIIII IIIIIIIIIIIIIIIIIII IIIIII_IIIII f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ----------------Reserved ------------- 67 L 70 L 71 Iu j 72 I ti I 731 '74 75 80 LJ LLJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES aermit Number) 09:30AM 15/09/16 12103/01 Chemours Company -Fayetteville Works Exit Time/Date permit Expiration Date 22828 NC Highway 87 West 12:30PM 15/09/16 16/10!31 Fayetteville NC 283067332 Name(s) of Onsite Representative(s)ITities(s)/Phone and Fax Number(s) Other Facility Data !// Jamie Ray Lewis/ORC1910-678-1219/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Michael E Johnson,22828 NC Highway 87 West Fayetteville NC No 28306733211910-678-1155/ Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit E Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program N Sludge Handling Disposal Facility Site Review Eftluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Mark Brantley FRO WQ/1910-433-3300 Ext.727/ C� Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date p B 'n aS H nson WQ//910-433-3300 Ext.72( C— 'tr` EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type (Cont.) 1 31 NC0003573 '11 12 15/09/16 17 18 (qj Section D: Summary of Finding/Comments (Attach additional sheets ofnarrative and checklists as necessary) Comments -Facility was clean and neat in appearance at the time of the inspection. -Maintenance records are maintained on an electronic work order system. •ORC logbooks are well kept. Laboratory records for the month of February 2015 were compared to the monthly DMR and no transcription errors were found at that time. -Facility's NPDES permit will expire on October 31, 2016. Please remember that the permit renewal application is to be submitted at least 180 days prior to the expirations date. -Enclosed is a registration form for the Division of Water Resources eDMR program. Once the facility is registered staff from the Fayetteville Regional Office will conduct a technical help session for Chemours Staff. Page# 2 Permit: NC0003573 Owner - Facility: Chemours Company -Fayetteville Works Inspection Date: 09/16/2015 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? M ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ 0 ❑ application? ❑ ❑ ❑ ❑ Is the facility as described in the permit? ❑ ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? M ❑ ❑ ❑ Is all required information readily available, complete and current? ❑ ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? ❑ ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? 0 ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? M ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? M ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? 0 ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? 0 ❑ ❑ ❑ Page# 3 Permit: NC0003573 Owner - Facility: Chemours Company -Fayetteville Works Inspection Date: 09/16/2015 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 0 - Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? M ❑ ❑ ❑ Is the flow meter operational? M ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? ❑ ❑ 0 ❑ Comment: Aerobic Digester Yes No NA NE Is the capacity adequate? M ❑ ❑ ❑ Is the mixing adequate? M ❑ ❑ ❑ Is the site free of excessive foaming in the tank? 0 ❑ ❑ ❑ # Is the odor acceptable? N ❑ ❑ ❑ # Is tankage available for properly waste sludge? 0 ❑ ❑ ❑ Comment: Solids Handling Equipment Yes No NA NE Is the equipment operational? ❑ ❑ ❑ Is the chemical feed equipment operational? ❑ ❑ ❑ Is storage adequate? ❑ ❑ ❑ Is the site free of high level of solids in filtrate from filter presses or vacuum filters? ❑ ❑ ❑ 0 Is the site free of sludge buildup on belts and/or rollers of filter press? ❑ ❑ ❑ 0 Is the site free of excessive moisture in belt filter press sludge cake? ❑ ❑ ❑ ❑ The facility has an approved sludge management plan? M ❑ ❑ ❑ Comment: Page# 4 Permit: NC0003573 Owner - Facility: Inspection Date: 09/16/2015 Inspection Type: Chemours Company -Fayetteville Works Compliance Evaluation Mode of operation Fact. Air Secondary Clarifier Yes No NA NE Is the clarifier free of black and odorous wastewater? E ❑ ❑ ❑ Is the site free of excessive buildup of solids in center well of circular clarifier? M ❑ ❑ ❑ Are weirs level? 0 ❑ ❑ ❑ Is the site free of weir blockage? 0 ❑ ❑ ❑ Is the site free of evidence of short-circuiting? ! ❑ ❑ ❑ Is scum removal adequate? 0 ❑ ❑ ❑ Is the site free of excessive floating sludge? N ❑ ❑ ❑ Is the drive unit operational? N ❑ ❑ ❑ Is the return rate acceptable (low turbulence)? M ❑ ❑ ❑ Is the overflow clear of excessive solids/pin floc? 0 ❑ ❑ ❑ Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) 0 ❑ ❑ ❑ Comment: Aeration Basins Yes No NA NE Mode of operation Fact. Air ❑ 110 Type of aeration system Diffused 0 ❑ Is the basin free of dead spots? 0 ❑ ❑ ❑ Are surface aerators and mixers operational? ❑ ❑ 0 ❑ Are the diffusers operational? N ❑ ❑ ❑ Is the foam the proper color for the treatment process? 0 ❑ ❑ ❑ Does the foam cover less than 25% of the basin's surface? ■ ❑ ❑ ❑ Is the DO level acceptable? ! ❑ ❑ ❑ Is the DO level acceptable?(1.0 to 3.0 mg/1) 0 ❑ ❑ ❑ Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? i ❑ 110 Is sample collected below all treatment units? 0 ❑ ❑ ❑ Is proper volume collected? N ❑ ❑ ❑ Is the tubing clean? E ❑ ❑ ❑ # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees ❑ ❑ ❑ Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type N ❑ ❑ ❑ representative)? Page# 5 Permit: NC0003573 Inspection Date: 09/16/2015 Effluent Sampling Comment: Upstream / Downstream Sampling Owner - Facility: Chemours Company -Fayetteville Works Inspection Type: Compliance Evaluation Is the facility sampling performed as required by the permit (frequency, sampling type, and sampling location)?. Comment: Facility is a member of the Middle Cape Fear River Basin Association Yes No NA NE Yes No NA NE ❑ ❑ N ❑ Page# 6