HomeMy WebLinkAboutDEQp00022638STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES Division of Water Quality Suite 714, Wachovia Bldg. Fayetteville, North Carolina 28301 July 21, 1997 MICHAEL JOHNSON DUPONT-FAYETTEVILLE P.O. DRAWER Z FAYETTEVILLE NC 28302 SUBJECT: Notice of Violation - Effluent Limitations NPDES No. NC0003573 DUPONT-FAYETTEVILLE BLADEN County Dear MICHAEL JOHNSON: Review of subject self-monitoring report for the month of April, 1997 revealed violation(s) of the following parameter(s): Reported Limits Pipe Parameter Value/Unit Value/Type/Unit 001 00530 RES/TSS 1715.7 LBS/DA 1030.0 FIN LBS/DA Remedial actions, if not already implemented, should be taken to correct the problem(s). The Division of Water Quality may pursue enforcement actions for this and.any additional violations of State Law. If you have questions or if you need assistance, please call Michael C. Wicker, Regional Water Quality Supervisor, at 910/486-1541. Sincerely, -V. Kerr T. Stevens Regional Supervisor CC: Central Files GKBDEX96/BL L6 E0 p DuPont Fluoroproducts P. 0. Drawer Z Fayetteville, NC 28302-1770 ome DuPont Fluoroproducts April 16, 1997 NC Dept. of Environment, Health, and Natural Resources Division of Environmental Management Central Files P. O. Box 29535 b aob�Raleigh, NC 27626-0535 RE: NPDES Permit No. NC0003573 TSS Exceedance - April 7, 1997 Dear Sirs: The April 7, 1997, Outfall 001 sample was measured as 1,715 lb/day Total Suspended Solids (TSS) versus the Daily Maximum permit limit of 1,030 lb/day. The likely cause of the TSS exceedance is that gas bubbles either under or throughout the sludge blanket in both clarifiers caused the sludge to float, resulting in the discharge of the biomass to Outfall 001. The site's ORC was successful in minimizing the amount of sludge discharged, and returning the system to normal. The Outfall 001 samples for April 8 and 9, 1997, indicate that the TSS level has returned to the normal amount of less than 150 lb/day. Therefore, we do not anticipate that the Monthly Average limit of 317.8 lb/day will be exceeded for the month of April 1997. If you have any questions regarding this matter, please feel free to call me at (910) 678-1155. Michael E. Johnson Environmental Coordinator cc: Ms. Kitty Kramer, Fayetteville Regional Office E. I. du Pont de Nemours and Company Printed on Recycled Paper FLA State of North Carolina Department of Environment, Health and Natural Resources Fayetteville Regional Office James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary Mr. Michael Mayberry E.I. Dupont PO Drawer 7 Fayetteville, NC 28302 Dear Mr. Mayberry: MW �0=% M000% a E)EHNR DIVISION OF WATER QUALITY January 17, 1997 SUBJECT: Compliance Evaluation Inspection E.I. Dupont de Nemours WWTP NPDES Permit No. NC0003573 Bladen County Please find enclosed a copy of the Compliance Evaluation Inspection Report for the inspection conducted on January 16,1997, by Mr. D.T. Jones of this office. The report should be self-explanatory and contains observations and recommendations. If you have any questions or require additional clarification, please do not hesitate to contact me at (910) 486-1541. Sincerely 4d D.T. Joo Chemist DTJ/bs EnclosureL6 00 tjVj, L6 zZ NVr c` .Tj Roger Pfaff , • v fry i' ° i 1i` A - !'j AS 00.ai Wachovia Building, Suite 714, Fayetteville 4 -r* - North 910-486-0707 North caroling 6-15415043 NDC An Equal Opportunity Affirmative Action Employer Voice 910-486-1541 5M recycled/ 10% post -consumer paper NPDES COMPLIANCE INSPECTION REPORT Division of Water Quality Fayetteville Regional Office Section A. National Data System Coding Transaction Code: N NPDES NO. NC0003573 Date:970116 Inspection Type: C Inspector: S Facility Type: 2 Facility Evaluation Rating: BI: N QA: N Section B: Facility Data Name and Location of Facility Inspected: E.I. Dupont de Nemours WWTP Entry Time: 1:00 p.m. Exit Time/Date: 970116 Name(s), Title(s) of On -Site Representative(s): Robert Geddie (Cert. Lic. Gr. IV) - "ORC" Kenneth Hall (Cert. Lic. Gr. III) - "Back-up Operator" Mike Johnson - Environmental Coordinator (No License) John Johnson (Cert. Lic. Gr. Il) - "Operator" Phone Number(s): 910-678-1219 Name, Title and Address of Responsible Official: Michael Mayberry - Plant Manager Phone Number: 910-678-1223 Section C: Areas Evaluated During Inspection Reserved: Reserved: Permit Effective Date: 960901 Permit Expiration Date: 010531 Contacted: No (S = Satisfactory, M = Marginal, U = Unsatisfactory, N = Not Evaluated) Section D: Summary of Findings/Comments: 1. According. to the DMR data reviewed for the period December 1995 through October 1996, the plant's effluent was in compliance with the NPDES permit's limits. 2. Aqua -Tech Laboratory performs the "outside" permit required analytical work for the facility. 3. All logs, calibrations, and records were being adequately maintained. 4. Fischer and Porter last checked/calibrated the effluent flow meter in October 1996. 5. On the day of inspection, a grab sample of the effluent revealed a settleable solids level of a trace/ltr of settleable solids with a relatively clear supernatant in the test vessel (Imhoff Cone). 6. DMR and laboratory data agree for discharge pipe .001 for June 1996 (spot check). 7. Sludge is (was) routed from the bottom of the clarifier to the "DAF" unit and from there to the sludge holding tank. The screw press then dewaters the sludge to about 12-14%. Dryers then dewater the sludge to about 45-50%. It is then put in bins and delivered to "BFI" site in Roseboro where it is disposed. Name and Signature of Inspector Agency/Office/Telephone D.T. Jones j �(910)486-1541 ayetteville /j Name and Signature of Reviewer Paul Rawls Agency/Office/Telephone DEHNR/Fayetteville (910)486-1541 Regulatory Office Use Only Action Taken Date Noncompliance -Compliance Date 1/16/97 Date 1-1-1 7 Compliance Status r