Loading...
HomeMy WebLinkAbout20060808 Ver 1_Complete File_20060713Staff Report Project Num: 20060808 Name: NCDOT- SR 1588 County: Macon Location: Walnut Creek Franklin Latitude: +35°10'19" Version: 1 Status: Issued Project Type: Pave road Region: Asheville Longitude: -83°15'16" SW Plan Location: Owner: NC DOT Division 14 - Andrews Contact Person: Tippett, Lyndo Title: Phone: Inspection Date: 06/08/2006 Entry Time: 09:40 AM Exit Time: 10:00 AM Reason for Inspection: Routine Inspection Type: Staff Report On-Site Representative(s): Primary Inspector: Michael R Parker Secondary Inspector(s): Question Areas: 0 Site Visit Inspection Summary: Phone: 828-296-4500 DOT is proposing to grade, widen and pave NCSR 1588 in Macon County. Proposed impacts are for 35 linear feet of new pipe and 182 linear feet of stream relocation and the replacement of two existing driveway culverts. During the site visit on 06-08-2006 additional impacts were noted that were not included in the application. Mark Davis DEO Division 14, has gone back to review the project and he indicated to me in a telephone conversation on 06-13-2006 that there were additional impacts and a new revised application would be submitted within the next week. It is recommended that WQ Certification Nos. 3404 and 3366 be issued. The 401 Certification was issued on July 13, 2006. Page: 1 Project Num: 20060808 Owner: NC DOT Division 14 - Andrews Inspection Date: 06/08/2006 Inspection Type: Staff Report Reason for Visit: Routine Site Visit Yes No NA NE Do impacts described in the application differ those seen in the field? ¦ ? ? ? If yes, please describe differences: Are the Intermittent/Perennial calls different in the application? ¦ ? ? ? If yes, please describe differences, and how mitigation ratios are affected: Are there additional impacts not described in the application? ¦ ? ? ? If yes, please describe and quantify: Were the impacts in place prior to the application for the 401 Certification? ? ¦ ? ? Additional conditions recommended for the Certification: Recommended project modifications: Is this a modification request to an existing Certification? ? ¦ ? ? Are there additional stromwater conditions that should be required due to the following classifications: ? ¦ ? n # 303(d)list, Class WS, NSW, ORW, HQW Describe: Is this a subdivision or otherwise part of a larger project? ? ? ¦ ? # If yes, what phase is this? Are there prior impacts from prior phases? ? ? ¦ ? If yes, what are the cumulative imacts for this project? Possible secondary impacts noted: Comment: Page: 2 ??F W AT ?RQ Michael F. Easley, Governor ?c G Q William G. Ross Jr., Secretary ?- North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director _ l? ?- e,0 ??? ??/' ? Division of Water Quality !1r r T +1i a?/J? 'cos oR?Gpcr/ ?(' July 13, 2006 Macon County gTF?,e, DWQ Project No. 060808 cy NCSR 1588 (Stiwinter Mountain Road) APPROVAL of 401 Water Quality Certification with Additional Conditions Mr. J. B. Setzer, P.E. Division Engineer N C Department of Transportation 253 Webster Road Sylva, North Carolina 28779 Dear Mr. Setzer: You have our approval, in accordance with the attached conditions and those listed below, to impact 216 linear feet in three (3) unnamed tributaries to Walnut Creek (34 linear feet of new pipe, replace two (2) existing driveway culverts, relocate 182 linear feet of roadside stream channel and temporary dewatering), in order to make improvements to NCSR 1588 (Stiwinter Mountain Road) in Macon County. The project should be constructed in accordance with your application dated May 11, 2006 (received May 16, 2006) and revised application dated July 6, 2006 (received July 10, 2006), including the environmental commitments made in the application letter. After reviewing your application, we have decided that this fill is covered by General Water Quality Certification Nos. 3404 and 3366, corresponding to the U.S. Army Corps of Engineers Nationwide Permit Numbers 14 and 33. In addition, you must acquire any other federal, state or local permits before you proceed with your project including (but not limited to) Sediment and Erosion Control, Non-Discharge and Water Supply Watershed regulations. This Water Quality Certification will expire with the accompanying 404 Permit issued by the US Army Corps of Engineers. This approval is valid solely for the purpose and design described in your application (unless modified below). Should your project change, you must notify the DWQ in writing and submit a new application. If the property is sold, the new owner must be given a copy of this Certification and approval letter, and is thereby responsible for complying with all the conditions. If total wetland fills for this project (now or in the future) exceed one acre, or if total impacts to streams (now or in the future) exceed 150 linear feet, compensatory mitigation may be required as described in 15A NCAC 2H .0506 (h) (6) and (7). For this approval to be valid, you must follow the conditions listed in the attached certification and any additional conditions listed below. 1. Erosion and sediment control practices must be in full compliance with all specifications governing the proper design, installation and operation and maintenance of such Best Management Practices in order to protect surface waters standards: a. The erosion and sediment control measures for the project must be designed, installed, operated, and maintained in accordance with the most recent version of the North Carolina Sediment and Erosion Control Planning and Design Manual. b. The design, installation, operation, and maintenance of the sediment and erosion control measures must be such that they equal, or exceed, the requirements specified in the most recent version of the North Carolina Sediment and Erosion Control Manual. The devices shall be maintained on all construction sites, borrow sites, and waste pile (spoil) projects, including contractor-owned or leased borrow pits associated with the project. Noe Carolina Nlaturally North Carolina Division of Water Quality 2090 U.S. Highway 70 Swannanoa, NC 28778 Phone (828) 296-4500 Customer Service Internet: www.ncwaterquality.org FAX (828) 299-7043 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer Mr. J. B. Setzer, P.E. July 13, 2006 Page Two c. For borrow pit sites, the erosion and sediment control measures must be designed, installed, operated, and maintained in accordance with the most recent version of the North Carolina Surface Mining Manual. d. The reclamation measures and implementation must comply with the reclamation in accordance with the requirements of the Sedimentation Pollution Control Act. 2. There shall be no excavation from or waste disposal into, jurisdictional wetlands or waters associated with this permit without appropriate modification. Should waste or borrow sites be located in wetlands or streams, compensatory mitigation will be required since that is a direct impact from road construction activities. 3. Sediment and erosion control measures shall not be placed in wetlands or waters unless otherwise approved by this Certification. If placement of sediment and erosion control devices in wetlands and waters is unavoidable, they shall be removed and the natural grade restored upon completion of the project. 4. Placement of culverts and other structures in waters, streams and wetlands, shall be placed below the elevation of the streambed by one foot for all culverts with a diameter greater than 48-inches, and 20 percent of the culvert diameter for culverts having a diameter less than 48-inches, to allow low flow passage of water and aquatic life. Design and placement of culverts and other structures including temporary erosion control measures shall not be conducted in a manner that may result in dis-equilibrium of wetlands, streambeds or banks, adjacent to, or upstream and down stream of the above structures. The applicant is required to provide evidence that equilibrium is being maintained, if requested in writing by DWQ. If this condition is unable to be met due to bedrock or other limiting features encountered during construction, please contact the NC DWQ for guidance on how to proceed and to determine whether or not a permit modification will be required. 5. Adequate sedimentation and erosion control measures must be installed and maintained on the project site to minimize sediment transport to downstream aquatic resources. Temporary cover (wheat, millet or similar annual grain) or permanent herbaceous cover should be planted on all bare soil within fifteen (15) days of ground disturbing activities to provide long-term erosion control. Erosion control mating should be used in conjunction with appropriate seeding on disturbed soils in steep slope and riparian areas. Matting should be secured in place with staples or wherever possible, live stakes of native trees. Straw mulch and tall fescue should not be used in riparian areas. 6. In-stream work and land disturbance within the 25-foot wide buffer zone are prohibited during the trout-spawning season of January 1 through April 15 to protect the egg and fry stages of trout from off-site sedimentation during construction of the roadway. 7. Compensatory mitigation for impacts to 216 linear feet of streams at a replacement ratio of 1:1 is required. We understand, based on the 401 Certification Application, that you have chosen to perform compensatory mitigation for impacts to streams through the North Carolina Ecosystem Enhancement Program (EEP). 8. The dimension, pattern and profile of the stream, above and below the crossing, should not be modified. Disturbed floodplains and streams should be restored to natural geomorphic conditions. 9. For projects impacting waters classified by the NC Environmental Management Commission as Trout (Tr), High Quality Waters (HQW) or Water Supply I or H (WS I or WS II), stormwater shall be directed to vegetated buffer areas, grass lined ditches or other means appropriate to the site for the purpose of pre-treating storm water runoff prior to discharging directly into streams. Mowing of existing vegetated buffers is strongly discouraged. 10. Native riparian vegetation (e.g. rhododendron, dog hobble, willows, alders, sycamores, dogwoods, black walnut and red maple) must be reestablished within the construction limits of the project by the end of the growing season following completion of construction. 11. Any riprap placed for bank stabilization should be limited to the streambank below the high water mark, and vegetation should be used for stabilization above the high water elevation. Riprap should not be place in the active thalweg channel or placed in the streambed in such a manner that precludes aquatic life passage. Bioengineering boulders or structures should be properly designed, sized and installed. 12. Heavy equipment should be operated from the banks rather than in the stream channels in order to minimize sedimentation and reduce the introduction of other pollutants into the stream. 13. All mechanized equipment operated near surface waters must be regularly inspected daily and maintained to prevent contamination of stream waters from fuels, lubricants, hydraulic fluids, or other toxic materials. 14. Rock check dams at culvert outlets should be removed at project completion to avoid impeding aquatic life movement. 15. All work in or adjacent to stream waters shall be conducted in a dry work area. Approved BMP measures from the most current version of NCDOT Construction and Maintenance Activities manual such as sandbags, rock berms, cofferdams and other diversion structures should be used to prevent excavation in flowing water. Mr. J. B. Setzer, P.E. July 13, 2006 Page Three 16. Discharging hydroseed mixtures and washing out hydroseeders and other equipment in or adjacent to surface waters is prohibited. 17. If concrete is used during construction (e.g., headwalls), a dry work area should be maintained to prevent direct contact between curing concrete and stream water. Water that inadvertently contacts uncured concrete should not be discharged to surface waters due to the potential for elevated pH and possible aquatic life and fish kills. 18. No rock, sand or other materials shall be dredged from the stream channel, except where authorized by this certification. 19. The permittee and its authorized agents shall conduct its activities in a manner consistent with State water quality standards (including any requirements resulting from compliance with §303(d) of the Clean Water Act) and any other appropriate requirements of State or Federal law. If DWQ determines that such standards or laws are not being met (including failure to sustain a designated achieved use) or that State of Federal law if being violated, or that further conditions are necessary to assure compliance, DWQ may reevaluate and modify this certification. 20. This certification does not authorize the discharge of waste rock and dirt into the stream or riparian zone except for permitted areas associated with the bank stabilization work. 21. During the construction of the project, no staging of equipment of any kind is permitted in waters of the U.S., or protected riparian buffers. 22. Upon completion of the project, the NCDOT Division Engineer, shall complete and return the enclosed "Certificate of Completion Form" to notify NCDWQ when all work included in the §401 Certification has been completed. This form shall be returned to the Transportation Permitting Unit of the NC Division of Water Quality, 2321 Crabtree Blvd., Suite 250, Raleigh, North Carolina 27604. If you do not accept any of the conditions of this certification, you may ask for an adjudicatory hearing. You must act within 60 days of the date that you receive this letter. To ask for a hearing, send a written petition, which conforms to Chapter 150B of the North Carolina General Statutes to the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, N.C. 27699-6714. This certification and its conditions are final and binding unless you ask for a hearing. This letter completes the review of the Division of Water Quality under Section 401 of the Clean Water Act. If you have any questions, please telephone Mr. Mike Parker of the Asheville Regional Office at 828.296.4500. Sincerely, Ldtee 17 Ian W. Klimek, P.E., Director uu Division of Water Quality Attachment cc: Mark Davis, Division 14, DEO Ed Ingle, Roadside Environmental Steve Lund, USACE Asheville Field Office Transportation Permitting Unit Mike Parker, Asheville Regional Office L77 N d mays 011"11 STATE OF NORTH CAROLINA DEPARTMENT OF TRANSPORTATION MICHAEL F. EASLEY GOVERNOR July 6, 2006 Mr. David K. Baker, NCDOT Regulatory Project Manager U.S. Army Corps of Engineers 151 Patton Avenue, Room 208 Asheville, NC 28801-2714 Subject: Nationwide 14 Permit Application (Revised) SR 1588 - Stiwinter Mountain Road LYNDO TIPPETT SECRETARY lam, of 10 "?4iy0S ?Vi p' 4y ?O ghOSTTFRQU 06, RB?cH Macon County State Project No. 14C.056009 (DWQ Minor Permit Fee $200) Dear Mr. Baker: 060808 The North Carolina Department of Transportation (NCDOT) recently submitted a permit application for the above referenced project. After submission of the application, it was brought to our attention that there were two sites inadvertently omitted from the original permit application. Please find attached a revised permit application. I apologize for any inconvenience this has caused. The NCDOT is proposing to widen, grade, and pave SR 1588, Stiwinter Mountain Road, in Macon County to a standard 18-foot roadway. The proposed improvements of SR 1588 have been identified as necessary maintenance and safety improvements. Funds have been allocated for this project and NCDOT would like to construct the project during the 2006-construction season. I am sending drawings for pipe culvert replacements, a marked county map and a USGS quad map. We propose to install the new culverts slightly below the existing streambed elevations where bedrock is not encountered to minimize impacts to aquatic habitats and allow the existing stream gradients to remain as unchanged as physically possible. Andrews District Office 191 Robbinsville Road Andrews, NC 28901 A* IsanbaI Iluuod sup,3unuaouoo auI of A1133-11p Iuaulluoa oI `(ZOQON) .Iaauaug suolluiad0 ploi3 Iuluauzuozinug apispuOU `OI2UI P3 *JW Put' SJuaHOW UW Sul?lsu ure I `UOPIPPn uI •(OAVI 1411L aaWA uotsinlQ `(ZINgQ) saainoso-d IummuN puu IuoulawlAug jo Iuou4mdaQ uuilo o gpoN agl uzojj IOV zaluAA. uua10 Dip jo IOI, uoilooS iapun uolluzuoglnu 5ugsanbaz um I `.algal snpjo Sdoo Xq `oslV •isonbai Iluua,,l apimuozluN tot, Dip 5uiuza3uoo noX of Xlloazlp Iuauzuloo of (O dM;DM) uolsslulMo0 sao.Inosold OMPHAk uullOJUO gl.IoN oql jo `zoluulpzoo0 uol.2a-d urelunow `flulaHOW ptnuQ *JW 5uplsu um I `?allal sell jo Moo Xg anoqu paulllno su Iauuugo u 5uptloolai put, sodid oqI ftouldai glim paaoozd of loV talurn usala oql jo {,O{, uollooS Iapun uolluzuoglnu 5ullsonbaz Xgang sI ZOQON Iasi nouil Z81 Iouduq tiiujoduzas laaj nouil I7£ louduzl luouuuuad IulojL palsanbag silm xad 19Z dY D ,tZ X ,gJ7 dWO J7Z X ,OZ S17+LZ `Z NIS i- dwo 1181 X IN atlsuid poluzoi.Iad 119 X G IZ d Z olis 101 dwD Il 7Z X I0£ dwD 1191 X IN Z olis 0 dwo 1181 X I0£ dWD «SI X ,OE OL+I `V I MIS O IauuugD opispuoW olqulS paluoolaz jo IozJ Z81 iaUlMg0 OMSPuOU fuipoag jo laai Z8I L6+1 `I MIS ° s;auduiI aN uouipuo0 pasodoad uoplpuoa 2URSIx9 U01 *ON axis •sloudun posodord oql jo famiums u si moloq palsl l •(.zZ O ssulo bAk(j) looio InuluAA, oI sauulnqul pauzuuun uI sl.Ianlna Iulaul oml aouldaz puu louuugo u oluoolaz of 5uusonbaz sI LO(ION `XiluajjiaadS ulsug ian d aassauUO I, apli'I agl uI salulS palzun agl JO saalum loudun of Xnssooou aq Illm Ii `sprepuuls puoz Xnpuooos luouno mo illim oouupioaou ui loofozd oql Ion4suoo of tapzo ul •snout'dug jo sdzo0 XuuV •S•n oql jo uoilolpsunf oql zapun an suxea.zls aql anailoq om `suosuaz osagl iod •uollula$an )Iau1 slauuugo agl `XIluuoillppV •olggoo put, Ianuf puns jo posodum on slouuugo umo4s oU •suz o4s luiuuazad 11uuls are sauulnqul poureuun aqs sallalS pallun aq;;o saaluA-k o; s;audml •saolnap zmllag gltm paouldal Slalntpounut ag Ilim Amp `popuolul su guulollouna lou are somop pouuuld zip jj •pattouuoo AlanllaajJa guioq si uoisoza put, uolluluauupas amsuo of A11UP samsuaul Io.Iluoo uolsoza IIu matna.I Iltm uuuzaJOJ uollonllsuoo aqL •loofozd sup uo uolsoja puu uoilrluoullpas louuoa put, ozimiulul of posn oq Illm soollouzd Iuaum2uuuul Isaq agZ •soioods pazafuepua puu paualvomp uo «1aa33a ou„ anug Illm loafoid slgl `suosuaz osagl zo3 •Iumiulul aq Illm loafozd sup uzo4 sloudim ags •gsg .ioj Iullgug apinozd of ozis luatoUjns jo lou are Alqugozd put, slassnul poddns of azis Iuatoljns jo lou azu puu lluuzs are paloudull aq of souulnqul pouzuuun agZ pagszalunn ?IaaaO InuleAk agl.ioj palsll smods pazafuupua puu poualua.Igl jo spzoooi ou on, om-LU •saioods paraiiuupuo put, poualu iql jo spzooaz joj pa3loago sum osuquluQ a&uluaH IumluN uullo.IUO WON agy If you have any questions or need additional information, please contact me at (828) 321-4105. Your early review and consideration will be greatly appreciated. Sincerely, Joshua B. Deyton, P.E. County Maintenance Engineer cc: Mr. John Hennessy, DWQ, DENR, Raleigh (seven copies) Mr. David McHenry, Mountain Region Coordinator, NCWRC Mr. Mike Parker, DWQ, DENR, Asheville Mr. Joel Setzer, P.E., Division Engineer, NCDOT Mr. Mark Davis, Division Environmental Officer, NCDOT Mr. E. L. Ingle, Roadside Environmental Field Operations Engineer, NCDOT 4r x OF VVAT€O ?Q Pre-Construction Notification (PCN) Application Form For Section 404 and/or Section 10 Nationwide, Regional and General Permits, Section 401 General Water Quality Certifications, and Riparian Buffer and Watershed Buffer Rules SR 1588, Stiwinter Mountain Road, Macon County of ?sorcm 6 ?i ?t 'rurl$aNSea NCDOT Division 14, District III Prepared By: Joshua B. Deyton, P.E. Page 1 Office Use Only: Form Version May 2002 SU808 USACE Action ID No. DWQ No. (If any particular item is not applicable to this project, please enter "Not Applicable" or "N/A".) 1. Processing 1. Check all of the approval(s) requested for this project: ® Section 404 Permit ? Riparian or Watershed Buffer Rules ? Section 10 Permit ? Isolated Wetland Permit from DWQ ® 401 Water Quality Certification 2. Nationwide, Regional or General Permit Number(s) Requested: NW 14 3. If this notification is solely a courtesy copy because written approval for the 401 Certification is not required, check here: ? 4. If payment into the North Carolina Ecosystem Enhancement Program (NCEEP) is proposed for mitigation of impacts (verify availability with NCEEP prior to submittal of PCN), complete section VIII and check here: 5. If your project is located in any of North Carolina's twenty coastal counties (listed on page 4), and the project is within a North Carolina Division of Coastal Management Area of Environmental Concern (see the top of page 2 for further details), check here: ? II. Applicant Information 1. Owner/Applicant Information Name: North Carolina Department of Transportation (NCDOT) Mailing Address: 191 Robbinsville Road Andrews NC 28901 Telephone Number: 828.321.4105 Fax Number: 828.321.3228 E-mail Address: jbdeyton@dot.state.nc.us 2. Agent Information (A signed and dated copy of the Agent Authorization letter must be attached if the Agent has signatory authority for the owner/applicant.) Name: Joshua B. Deyton P.E. Company Affiliation: County Maintenance Engineer Mailing Address: (same as above) Telephone Number: Fax Number: Page 2 E-mail Address: III. Project Information Attach a vicinity map clearly showing the location of the property with respect to local landmarks such as towns, rivers, and roads. Also provide a detailed site plan showing property boundaries and development plans in relation to surrounding properties. Both the vicinity map and site plan must include a scale and north arrow. The specific footprints of all buildings, impervious surfaces, or other facilities must be included. If possible, the maps and plans should includ6 the appropriate USGS Topographic Quad Map and NRCS Soil Survey with the property boundaries outlined. Plan drawings, or other maps may be included at the applicant's discretion, so long as the property is clearly defined. For administrative and distribution purposes, the USAC' E requires information to be submitted on sheets no larger than 11 by 17-inch format; however, DWQ may accept paperwork of any size. DWQ prefers full-size construction drawings rather than a sequential sheet version of the full-size plans. If full-size plans are reduced to a small scale such that the final version is illegible, the applicant will be informed that the project has been placed on hold until decipherable maps are provided. 1. Name of project: Stiwinter Mountain Road, SR 1588 2. T.I.P. Project Number or State Project Number (NCDOT Only): 14C.056099 3. Property Identification Number (Tax PIN): N/A 4. Location County: Macon Nearest Town: Franklin Subdivision name (include phase/lot number): N/A Directions to site (include road numbers, landmarks, etc.): From Franklin, take US 64/28 southeast to SR 1533, Walnut Creek Road. Turn left onto Walnut Creek and continue for approximately 4 miles to SR 1588, Stiwinter Mountain Road. See attached vicinity map. 5. Site coordinates, if available (UTM or Lat/Long): Site 1 - 35.1669° N 83.2531°W, Site lA - 35 1667° N 83.2447° W, Site 2 - 35.1719° N 83.2544° W, Site 2A - 35.1683° N 83 2456° W Site 3 - 35.1764° N 83.2572° W (Note - If project is linear, such as a road or utility line, attach a sheet that separately lists the coordinates for each crossing of a distinct waterbody.) 6. Property size (acres): 0.98 7. Nearest body of water (stream/river/sound/ocean/lake): Walnut Creek (C tr) 8. River Basin: Little Tennessee (Note - this must be one of North Carolina's seventeen designated major river basins. The River Basin map is available at h!tp://h2o.enr.state.nc.us/admin/ma-ps/.) Page 3 9. Describe the existing conditions on the site and general land use in the vicinity of the project at the time of this application: forest and light residential 10. Describe.the overall project in detail, including the type of equipment to be used: The road will be widened by clearing, grubbing, cutting and filling. Necessary drainage will be installed. Necessary drainage pipe will be installed and two culverts will be extended. A roadside seep will be relocated. The road will then be graded and paved. The work will be performed using hydraulic excavator, backhoes, loader, dozer, wheel loader, motor grader, dump trucks and hand tools. 11. Explain the purpose of the proposed work: To improve the secondary road by widening an d paving to bring the road to current secondary road standards. IV. Prior Project History If jurisdictional determinations and/or permits have been requested and/or obtained for this project (including all prior phases of the same subdivision) in the past, please explain. Include the USACE Action ID Number, DWQ Project Number, application date, and date permits and certifications were issued or withdrawn. Provide photocopies of previously issued permits, certifications or other useful information. Describe previously approved wetland, stream and buffer impacts, along with associated mitigation (where applicable). If this is a NCDOT project, list and describe permits issued for prior segments of the same T.I.P. project, along with construction schedules. V. Future Project Plans Are any future permit requests anticipated for this project? If so, describe the anticipated work, and provide justification for the exclusion of this work from the current application. None anticipated at this time. VI. Proposed Impacts to Waters of the United States/Waters of the State It is the applicant's (or agent's) responsibility to determine, delineate and map all impacts to wetlands, open water, and stream channels associated with the project. The applicant must also provide justification for these impacts in Section VII below. All proposed impacts, permanent and temporary, must be listed herein, and must be clearly identifiable on an accompanying site plan. All wetlands and waters, and all streams (intermittent and perennial) must be shown on a delineation map, whether or not impacts are proposed to these systems. Wetland and stream evaluation and delineation forms should be included as appropriate. Photographs may be included at the applicant's discretion. If this proposed impact is strictly for wetland or stream mitigation, list and describe the impact in Section VIII below. If additional space is needed for listing or description, please attach a separate sheet. Page 4 1. Provide a written description of the proposed impacts: Two culverts will be extended and two culverts will be replaced in small unnamed tributaries of Walnut Creek. Additionally, 182 feet of roadside seep will be moved away from the road to gain the necessary road width. 2. Individually list wetland impacts below: Wetland Impact Site Number (indicate on ma) Type of Impact* Area of Impact (acres) Located within 100-year Floodplain** (es/no) Distance to Nearest Stream (linear feet) Type of Wetland*** N/A * List each impact separately and identify temporary impacts. Impacts include, but are not limited to: mechanized clearing, grading, fill, excavation, flooding, ditching/drainage, etc. For dams, separately list impacts due to both structure and flooding. ** 100-Year floodplains are identified through the Federal Emergency Management Agency's (FEMA) Flood Insurance Rate Maps (FIRM), or FEMA-approved local floodplain maps. Maps are available through the FEMA Map Service Center at 1-800-358-9616, or online at http://www.fema.gov. *** List a wetland type that best describes wetland to be impacted (e.g., freshwater/saltwater marsh, forested wetland, beaver pond, Carolina Bay, bog, etc.) Indicate if wetland is isolated (determination of isolation to be made by USACE only). List the total acreage (estimated) of all existing wetlands on the property: N/A Total area of wetland impact proposed: N/A 3. Individually list all intermittent and perennial stream impacts below: Stream Impact Site Number indicate on ma) Type of Impact* Length of Impact (linear feet) Stream Name** Average Width of Stream Before Im act Perennial or Intermittent? ( leasespecify) Site #1 Roadside Seep (Relocation) 182 feet (Temporary) UT to Walnut Creek 0.5' P Site #IA Culvert (Driveway) None UT to Walnut Creek 0.5 P Site #2 Culvert 10 feet UT to Walnut Creek 1' P Site #2A Culvert (Driveway) _1 foot UT to Walnut Creek 1' P Site #3 Culvert 25 feet UT to Walnut Creek 0.5' P * List each impact separately and identify temporary impacts. Impacts include, but are not limited to: culverts and associated rip-rap, dams (separately list impacts due to both structure and flooding), relocation (include linear feet before and after, and net loss/gain), stabilization activities (cement wall, rip-rap, crib wall, gabions, etc.), excavation, ditching/straightening, etc. If stream relocation is proposed, plans and profiles showing the linear footprint for both the original and relocated streams must be included. Page 5 ** Stream names can be found on USGS topographic maps. If a stream has no name, list as UT (unnamed tributary) to the nearest downstream named stream into which it flows. USGS maps are available through the USGS at 1-800-358-9616, or online at www.us¢s.gov. Several internet sites also allow direct download and printing of USGS maps (e.g., www.topozone.com, www.mapguest.com, etc.). Cumulative impacts (linear distance in feet) to all streams on site: 34 Permanent 182 Relocation 4. Individually list all open water impacts (including lakes, ponds, estuaries, sounds, Atlantic Ocean and any other water of the U.S.) below: Open Water Impact Site Number (indicate on ma ,? Type of Impact* Area of Impact (acres) Name of Waterbody (if applicable) Type of Waterbody (lake, pond, estuary, sound, bay, ocean, etc.) N/A * List each impact separately and identify temporary impacts. Impacts include, but are not limited to: fill, excavation, dredging, flooding, drainage, bulkheads, etc. 5. Pond Creation If construction of a pond is proposed, associated wetland and stream impacts should be included above in the wetland and stream impact sections. Also, the proposed pond should be described here and illustrated on any maps included with this application. Pond to be created in (check all that apply): ? uplands ? stream ? wetlands Describe the method of construction (e.g., dam/embankment, excavation, installation of draw-down valve or spillway, etc.): N/A Proposed use or purpose of pond (e.g., livestock watering, irrigation, aesthetic, trout pond, local stormwater requirement, etc.): N/A Size of watershed draining to pond: N/A Expected pond surface area: N/A VII. Impact Justification (Avoidance and Minimization) Specifically describe measures taken to avoid the proposed impacts. It may be useful to provide information related to site constraints such as topography, building ordinances, accessibility, and financial viability of the project. The applicant may attach drawings of alternative, lower-impact site layouts, and explain why these design options were not feasible. Also discuss how impacts were minimized once the desired site plan was developed. If applicable, discuss construction techniques to be followed during construction to reduce impacts. Minimal lengths of pipe were used to achieve the minimum design widths for secondary roadways in North Carolina A roadside seep is being moved to prevent any net loss of channel. VIII. Mitigation Page 6 DWQ - In accordance with 15A NCAC 2H .0500, mitigation may be required by the NC Division of Water Quality for projects involving greater than or equal to one acre of impacts to freshwater wetlands or greater than or equal to 150 linear feet of total impacts to perennial streams. USACE - In accordance with the Final Notice of Issuance and Modification of Nationwide Permits, published in the Federal Register on March 9, 2000, mitigation will be required when necessary to ensure that adverse effects to the aquatic environment are minimal. Factors including size and type of proposed impact and function and relative value of the impacted aquatic resource will be considered in determining acceptability of appropriate and practicable mitigation as proposed. Examples of mitigation that may be appropriate and practicable include, but are not limited to: reducing the size of the project; establishing and maintaining wetland and/or upland vegetated buffers to protect open waters such as streams; and replacing losses of aquatic resource functions and values by creating, restoring, enhancing, or preserving similar functions and values, preferable in the same watershed. If mitigation is required for this project, a copy of the mitigation plan must be attached in order for USACE or DWQ to consider the application complete for processing. Any application lacking a required mitigation plan or NCEEP concurrence shall be placed on hold as incomplete. An applicant may also choose to review the current guidelines for stream restoration in DWQ's Draft Technical Guide for Stream Work in North Carolina, available at http://h2o.enr.state.nc.us/ncwetlands/strrngide.htrnl. 1. Provide a brief description of the proposed mitigation plan. The description should provide as much information as possible, including, but not limited to: site location (attach directions and/or map, if offsite), affected stream and river basin, type and amount (acreage/linear feet) of mitigation proposed (restoration, enhancement, creation, or preservation), a plan view, preservation mechanism (e.g., deed restrictions, conservation easement, etc.), and a description of the current site conditions and proposed method of construction. Please attach a separate sheet if more space is needed. N/A 2. Mitigation may also be made by payment into the North Carolina Ecosystem Enhancement Program (NCEEP). Please note it is the applicant's responsibility to contact the NCEEP at (919) 715-0476 to determine availability and to request written approval of mitigation prior to submittal of a PCN. For additional information regarding the application process for the NCEEP, check the NCEEP website at http://www.neegp.net. If use of the NCEEP is proposed, please check the appropriate box on page three and provide the following information: Amount of stream mitigation requested (linear feet): 34 Amount of buffer mitigation requested (square feet): N/A Amount of Riparian wetland mitigation requested (acres): N/A Amount of Non-riparian wetland mitigation requested (acres): N/A Page 7 Amount of Coastal wetland mitigation requested (acres): N/A IX. Environmental Documentation (required by DWQ) Does the project involve an expenditure of public (federal/state) funds or the use of public (federal/state) land? Yes ® No ? If yes, does the project require preparation of an environmental document pursuant to the requirements of the National or North Carolina Environmental Policy Act (NEPA/SEPA)? Note: If you are not sure whether a NEPA/SEPA document is required, call the SEPA coordinator at (919) 733-5083 to review current thresholds for environmental documentation. Yes ? No If yes, has the document review been finalized by the State Clearinghouse? If so, please attach a copy of the NEPA or SEPA final approval letter. Yes ? No ? X. Proposed Impacts on Riparian and Watershed Buffers (required by DWQ) It is the applicant's (or agent's) responsibility to determine, delineate and map all impacts to required state and local buffers associated with the project. The applicant must also provide justification for these impacts in Section VII above. All proposed impacts must be listed herein, and must be clearly identifiable on the accompanying site plan. All buffers must be shown on a map, whether or not impacts are proposed to the buffers. Correspondence from the DWQ Regional Office may be included as appropriate. Photographs may also be included at the applicant's discretion. Will the project impact protected riparian buffers identified within 15A NCAC 2B .0233 (Meuse), 15A NCAC 2B .0259 (Tar-Pamlico), 15A NCAC 2B .0250 (Randleman Rules and Water Supply Buffer Requirements), or other (please identify. N/A )? Yes ? No ® If you answered "yes", provide the following information: Identify the square feet and acreage of impact to each zone of the riparian buffers. If buffer mitigation is required calculate the required amount of mitigation by applying the buffer multipliers. Zone* Impact (square feet) Multiplier Required Mitigation 1 3 2 1.5 Total * Zone 1 extends out 30 feet perpendicular from near bank of channel; Zone 2 extends an additional 20 feet from the edge of Zone 1. If buffer mitigation is required, please discuss what type of mitigation is proposed (i.e., Donation of Property, Conservation Easement, Riparian Buffer Restoration / Enhancement, Preservation or Page 8 Payment into the Riparian Buffer Restoration Fund). Please attach all appropriate information as identified within 15A NCAC 2B .0242 or. 0260. XI. Stormwater (required by DWQ) Describe impervious acreage (both existing and proposed) versus total acreage on the site. Discuss stormwater controls proposed in order to protect surface waters and wetlands downstream from the property. The existing compacted gravel roadway acts as an impervious surface. Paving of the roadway should eliminate sedimentation from fines associated with gravel surface treatment. The roadway surface will be approximately 40% of the right-of-way area. Storm water will be diverted through settling basins lined with filtering stone or grass lined buffers prior to entering streams. (See erosion control plan) XII. Sewage Disposal (required by DWQ) Clearly detail the ultimate treatment methods and disposition (non-discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. N/A XIII. Violations (required by DWQ) Is this site in violation of DWQ Wetland Rules (15A NCAC 2H .0500) or any Buffer Rules? Yes ? No Is this an after-the-fact permit application? Yes ? No XIV. Other Circumstances (Optional): It is the applicant's responsibility to submit the application sufficiently in advance of desired construction dates to allow processing time for these permits. However, an applicant may choose to list constraints associated with construction or sequencing that may impose limits on work schedules (e.g., draw-down schedules for lakes, dates associated with Endangered and Threatened Species, accessibility problems, or other issues outside of the applicant's control). 41- `? - July 6, 2006 Applicant/Agent's Signature Date (Agent's signature is valid only if an authorization letter from the applicant is provided.) Page 9 SR. NO SR -1588 CPS` 3 RD, Nom= STIWINTER MT. RD. g PIPE STA-_ SITE No. 1 - G Q? STA. 2+00 I ' 1+50 , 7' f 1! e 1+00 9' J j 0+50 ! ' I -- STA. 0+22_ 17' '-q--WALNUT CREEK RD. alp S 10 0 1 N. 3 0 14 1 71 It K- Gs' . v? O EXIST. DR. PIPE f ' - 6" br. PROPOSED DR-PIPE 6" br. ?• - SHIFT EXIST. TO A POINT 16' RT. OF NEW CL PROP, 161 RT. OF NEW CL -EXIST. CROSS PIPE I I I 1 1 1 1 1 1 1 I I 1 1 1 1 1 1 1 1 1 ,. 1 1 1 I I I I I I t I I I I I at I I I I ? I ? I I I I I I I I i t I II I I I 1 I 11 I I ' I 1 I I I I I I I I I t 1 1 1 1 I I I I I ? I I I I I 1 1 1? 1 1 1 I I I I I I I 1 1 I I I I I I I I 1 V I I I I I I I 11 II II VIII I I I I I I I I I I 1 1? 1 a l I I I I I I I I I 1 1 1 I I I 1 I I I 1 1 I I I I 1 1 1 I I I 1 1 1 1 1 1 1 1 1 i I I I I I I I ' I I I 1 1 111 1 I I I I I I I I I I I 1 1I1 , 1 -1 4 - - -'-1 H t _ 1 4 - - _I. +1 1 H _, t 1 I 1 I I 1 I I ' I I I I I 1 1 I I i 1 I 1 ' - H 11 41 -1 H -7 I I I T ] IN II 1 I I I I I I ? I I I ? I I 1 I 1 1 1 i I I 11 I I I 1 1 I I I I I I t 1 I I I I I I I 1 1 I 1 i H 1 1' 1 I I I 1 I 1 I I I f i t 1 I 1 1 1 1 1 1 I 1 11 I I I i I I I I I I I I I IIII-I-I I I I I I I I II- F 1 ' I I I I 1 t l l l l l I I I 1 1 V I I I I I I I 1 1 1 I I I I' I! t 1 t I t I I I I I I I I 1 1 1 1 1 1 1 I I I 1 1 I I I I t t l l ?' COUNTY:_ MAC'ON GPS: 35 ° 10 00 " H. SR. NO. 1 5$ n --- RD. NAME:,-_a,_3d? ntPr mi- _ Rn 83 14 41 N- PIPE STA*_ 2+00 SITE No. #1 -A old/new ri cl CHECK DAMS AS RE SILT BASIN RIP RAP TYPE B HEADWALL 12x3x2 t 2' BR ?2+ 7' t?l 00 0 ? I SILT FENCE ( -? - - - -- - - - - - _ & t ? ROCK BERMS I ? 7• 1+70 F RIP RAP 'REPLACE END WALL WITH 30'x18"cmp, dr CHECK DAMS AS REQ. 2' BR V I I I I 1 1 1 1 1 1 1 I I I I I I I I I I I I I I 1 I I I 1 1 1 I I t l l I I I 1 1 1 1 1 1 1 1 1 1 I •-I 1 1 1 I I 1 1 1 I I I t l l l I I I I I I I I ( I 1 1 1 1 1 1 1 1 1 1 1 ?I I I I V I I I 1 1 1 1 1 1( 1 I i t I I 1 1 1 1 1 I I I I I 1 1 1 1 1 1 1 1 1 1 I I I I I 1 1 1 1 I I I I I I I I i I I I I I I-I i t IL I L I I 1 1 1 1 I I I I I t I I I I I I I I I I I I I I 1 1 1 I I I I I I I ' t V I I I I I I I 11 I I I I I I I I I 1 i I _ I _ I- I _ f {I _I I H l --- - _ I- - I l i lt I I t I t i ll , t 1 1 If I I I I I I I 1 ! t I I I 1 I I t I I 1 1 1 I I IC M !V 7- -1 771 7:'M I I -T j t --T 13 I I I T (I I gm v t L a -T I I I 1 1- I I I 5 LL I i l l 1 1 1 I 1 I I I I I I I I I + I I 1 I I I I i I S V 4 I 1 1 I I i l 1I I I I II 1 1 1 1 I I I l i I I I 1 1 1 1 1 1 1 1 I I I V I I I 1 1 1 1 I I I I I t I I I I I I I I 1 1 1 1 1 1 1 " 1 1 1 1 1 1 1 1. 1 1 1 1 1 1 I I i 1 i 1 1.--- I I 1 1? : 1 1 1 1 1 1 1 1 1 1 1 1 1 : 1 1 COUNTY: MACON GPS: 35 0 09 79rT N. SR. N0. ROAD ADDITION r rr RD Nom: STIWINTER MOUNTAIN Rd. 83 ° 14 76 W. PIPE STA-. 5+76 SITE No. 2 OLD . NEW y C EPA DAMS AS REQ O , BASIN E B 3'x2' SILT FENCE i i ROCK BERM _-? r x15" CS ?.u. EXISTING 2O I e PROP. 4' EII.DW ALL +I 1 R SILT FENCE & ., ROCK BERM / f -1 -NT5 4 -R C I4 Cy ?I? ??Tl 1 1 1??? i -I 1-1 1=1-LLI- oxx 1` $ PROP. 4' HEADWALL CHECK DAMS SPACED AS REQUIREDI i COUNTY:__M_ACON GPS: 35 0 10 SR. NO_ 1588 RD. NAHE: STIWINTER MOUNTAIN 83 ° 14 ` PIPE STA-. 6+25 SITE No. 2_A s 7+00 1 7 O ?HEW CL 6+50 i! r-f i 6+25 3 ?. - ? - 6+00? 5+75 2' •? ?`? ? 06 " N. 44 " K. P RAP HEADWALL i I REPLACE _ WITH co W - 20'x1 8"cmp I H I. ? 1 Q I RIP RAP ENDWALL . 2' BRANCH 1 1 1 1 1 1 1 1 1 ! I. 1 I 1 I 1 1 1 1 1 1 1 ! 1 1 1 1 t 1 I 1 1 1 1 I 1 1 1 1 1 1 1 1 1 1 I 1 1 I 1 1 1 I I I l I I I t l 1 1 1 1 1 I I I ' I I I I l f l I I I I= I 1 I XAEN rl tJ . 1 11 I V I I I 1 1 1 1 1 1 1 1 I I 1 I I 1 I 11 I 1 1 11r I I ?. I I I 1 1 1 I I I I I I 1 I 1 I I I I l i I I I • I I I I I ! I I I 1 1 1 I ! 1 1 1 1 1 I I I 1 1 1 1 ( 1 1 I ! 1 1 1 1 I I I I I I I ' f i l l l l I I I I I I I I I ( I I I 1 I I I _ I' 1 1 I i 1 ?? I l I I I I I I 1 I ? I ! 1 1 -1 - H I -I -J 1 1 - - 1 I I II I II I I 1 I I 1 1 I I 1 1 1 1 , I _ I 1 1 I I I ' ? I I 1 ! I d I ! ! ( I I I I ! I I I I11 II I I ? i I I I I 1 I I I ! I , I I I t I I I I 1 1 I 1 I 1 I I' 1 1 1 1 1 1 4 i! 1 1 1 1 1 1 1 1 1 I 1 1 1 I ' - l l l 1. l 1 1 I I 1 1 1 1 ? I I f l i ?- _ 1 1 1 I 1 1 1 1 1 1 1 11 I I I I l I I l l I l I I ? l t' UUUN-EZ : MACON - 91 SR. NO---RD. ADDITION GPS • 35 ° 09 I 95 N. n RD- NAME = STIWINTER MOUNTAIN g3 0 14 86 W. ' PIPE STA-. 9+85 END OF PROJECT SITE No_ 3 CL AT E.O.P. NEW PROP.3'HEADWAL SILT BASI ?.• OLD CL RT. SIDE ..f : ` TYPE B S OLD CL 2x3x CHECK DAMS AS REQ. S-F & R.B. TEMP. SILT FENCE y & ROCK BERM PROP. 6'ENDWALL CHECK DAMS ?. AS REQ. CHECK DAMS SIFT BASIN TYPE B 8'x 3'x 2' AS RE y 1 _7 -*- - - - - I - - - _ - - - - - J i NL 1 1 1 I II - ' ' I 11 1 1 1 11 1 I i 1 1 r)A7 +0 H ! - I _ - - - - - - - - - f i i I 1 _ Z Wit L I 1 1 1 - - - - - - - - - - - - - - - - - - i l 4 c l - T = - - - _ - - - - -- - - - _ - - - - - _ _ - _ _ - - - - - - - _ - _ _ _ _ ? - _ 2 0 - ` 1 T - - - - - - - - - -r - - - - - - - - - - - - - - - - - - T T - - - - - - - - - - - - = 5 - - = = T - - V 4 4 +4 - 03 ?0 O ??1 V L Mn 00 W kr) -. -1 m s aa+? ?. t ?N A r, + A I rn *?y1d • a i' I 8 ?` ofg F ! ? .4 ail ? +?•. ? lc? i T V L -cl 03 O P4 . r-I T? V 1 W TP4 V 1 r O r? FBI V 1 Mir r n 0 L ?.{ fY ? rV -, a t 'v f J l t ??ty 4:A ! ?r f 1 1 ? ?-..FS y- ? Cd O P4 . ro ?I OC) fin / 00 V 1 T? V 1 t. r r'?l 4!.j ? . •? -.;i R-4;v .C is«j•r'Y ?1 .+? f r it N O 1 N -4--J V 1 I N N O 0 a? V 1 Mn 00 00 V ? V1 :y w t 'r J 01,4- 'Wife. - 61 0 N V N V 1 e--r CD W CD W O t.4 '*, r• You + , - -l:? ?' l ? I Gr?aaaiii % ilk 1P i r s CA pc? 00 1..r r-P rr u? • I 1991 OOOZ slenbe youi 6 :aleoS Ajunoo uooeW 'peon{ ulelunoN jejuimilS `qqq? US :uolldeo 90OZILIL :ale(I M .6v'"34 0£80 N ,.l£'ZO M o9£O :u011eoo-1 3111AN319:aweN ajaaaC?.jnuteM zzgz 2J KNJair 959: 1Ff V?fl J )tanQ aIrit'F \ !, 1 / t e i G tl. `I 9S ? ooo' - j ??L? ?/ ?j? ulw aa;eM Mon8 ooo, `°?b?? \ ?l ` 0982 ) 1tO O219}l 99911 J Hl NF; ujV4 M,3egSc) , N + a t ', age a l_ / ?_? _ - /dam --? / ?? -i., ' `t / ,ri ?• ?- qou?j ?._ % C'p Baal1 ( gout'{ /, \ ! qouy9n way uro aepa? ?- deSf49i if+l vaF1 ?of£ / / C^tr \;nuleM penoajpnuai?-) ?junoj t `:_ i C1?t uooeW pb .,W U10 L ?aluin qg 99s l V ?? - ? ? _ ? --, Dour- - I - ,•/ - gou?j )lead -y ?gouyj r- gouts auolspuug 4W Pal.qM ot? S auo;spu,aq i'jj 1, o ? ? 1 flLE?l •'••. ?O?f ?\1 ?. /°S1J '?OYt. ? ,fV i. n d v 7 J -? LL N, H ' y ? 1 94 .is[tlI:? ! -.ice/.?,\? .--. / _ •-. ? x ` , r 0091 SR 1588 l I Y A r ? t ? w 1533 306 7 1 5a 1 ?-. a? /193 ? a s 1 I ? ° 1677 328--- 55 f{ ? J `v WK r ° f 177 A r /'200 r f I 1566 ?? r ti- t 53 a HOGBACK MTN. ELEV. 44950 15 t - 153? ? 1 r-- ti r -> *'- Gneiss 0106 F J f j I r?{ 1 1535 z- 1679 Ruck` " S 109 J 64 1674 . ilijj? 195 Brush ?? - 1679 SKY-HI - ?-? CII 0 CAMP f f yr J^ti f l./, t J 7 1 r- A A d?ST STATE OF NORTH CAROLINA ?OV Mq y 1 '101 6 °s?ay°s oR?"?i?y DEPARTMENT OF TRANSPORTATION ??ReRavcy MICHAEL F. EASLEY GOVERNOR May 11, 2006 LYNDO TIPPETT SECRETARY o Mr. Steve Lund, NCDOT Regulatory Project Manager - .S. Army Corps of Engineers :S 151 Patton Avenue, Room 208 Asheville, NC 28801-2714 06()808 Subject: Nationwide 14 Permit Application SR 1588 - Stiwinter Mountain Road Macon County Ul= State Project No. 14C.056009 (DWQ Minor Permit Fee 5200 ) Dear Mr. Lund: The North Carolina Department of Transportation (NCDOT) is proposing to widen, grade, and pave SR 1588, Stiwinter lvlountain Road, in Macon County to a standard 18-foot roadway. The proposed improvements of SR 1588 have been identified as necessary maintenance and safety improvements. Funds have been allocated for this project and NCDOT would like to construct the project during the 2006-construction season. I am sending drawings for pipe culvert replacements, a marked county map and a USGS quad map. We propose to install the new culverts slightly below the existing streambed elevations where bedrock is not encountered to minimize impacts to aquatic habitats and allow the existing stream gradients to remain as unchanged as physically possible. The North Carolina Natural Heritage Database was checked for records of threatened and endangered species. There are no records of threatened and endangered species listed for the Walnut Creek watershed. The unnamed tributaries to be impacted are small and are not of sufficient size to support mussels and probably are not of sufficient size to provide habitat for fish. The impacts from this project will be minimal. For these reasons, this project will have "no effect" on threatened and endangered species. The best management practices will be used to minimize and control sedimentation and erosion on this project. The construction foreman will review all erosion control measures daily to ensure sedimentation and erosion is being effectively controlled. If the planned devices are not functioning as intended, they will be immediately replaced with better devices. Impacts to Waters of the United States The unnamed tributaries are small perennial streams. The stream channels are composed of sand gravel and cobble. Additionally, the channels lack vegetation. For these reasons, we believe the Andrews District Office 191 Robbinsville Road, Andrews, N. C. 28901 Phone: (828) 321-4105 Fax: (828) 321-3228 I. streams are under the jurisdiction of the U.S. Army Corps of Engineers. In order to construct the project in accordance with our current secondary road standards, it will be necessary to impact waters of the United States in the Little Tennessee River Basin. Specifically, NCDOT is requesting to relocate a channel and replace two metal culverts in unnamed tributaries to Walnut Creek (DWQ Class C Tr). Listed below is a summary of the proposed impacts. Site No. Station Existing Condition Proposed Condition Net Impacts Site 1 20'x 15" CMP 30' x 24" CMP 10' Site IA, 1+97 182 feet of Eroding Roadside Channel 182 feet of relocated Stable Roadside Channel 0 Site 2, 27+45 20' x 24" CMP 45' x 24" CMP 25' Total Permanent Impact 35 linear feet Temporary Impact 182 linear feet Permits Requested NCDOT is hereby requesting authorization under Section 404 of the Clean Water Act to proceed with replacing the pipes and relocating a channel as outlined above. By copy of this letter, I am asking Mr. David McHenry, Mountain Region Coordinator, of the North Carolina Wildlife Resources Commission (NCWRC) to comment directly to you concerning the 404 Nationwide Permit request. Also, by copy of this letter. I am requesting authorization under Section 401 of the Clean Water Act from the North Carolina Department of Environment and Natural Resources (DENR), Division of Water Quality (DWQ). In addition, I am. asking Mr. McHenry and Mr. Ed Ingle, Roadside Environmental Field Operations Engineer (NCDOT), to comment directly to me concerning this permit request. If you have any questions or need additional information, please contact me at (828) 321-4105. Your early review and consideration will be greatly appreciated. Sincerely, Joshua B. Deyton, P.E. County Maintenance Engineer cc: Mr. John Hennessy, DWQ, DENR, Raleigh (seven copies) Mr. David McHenry, Mountain Region Coordinator, NCWRC Mr. Mike Parker, DWQ, DENR, Asheville Mr. Joel Setzer, P.E., Division Engineer, NCDOT Mr. Mark Davis, Division Environmental Officer, NCDOT Mr. E. L. Ingle, Roadside Environmental Field Operations Engineer, NCDOT A TFRQ ?O G > O Pre-Construction Notification (PCN) Application Form For Section 404 and/or Section 10 Nationwide, Regional and General Permits, Section 401 General Water Quality Certifications, and Riparian Buffer and Watershed Buffer Rules SR 1588, Stiinter Mountain Road, Macon County Of NORTH ?q b 7 o z O C 9?J PtC I" of Tilt P. NCDOT Division 14, District III Prepared By: Joshua B. Deyton, P.E. Page 1 Office Use Only: Form Version May 2002 20060808 USACP Action ID No. DWQ No. (If any particular item is not applicable to this project, please enter "Not Applicable" or "N/A".) I. Processing 1. Check all of the approval(s) requested for this project: ® Section 404 Permit ? Riparian or Watershed Buffer Rules ? Section 10 Permit ? Isolated Wetland Permit from DWQ ® 401 Water Quality Certification 2. Nationwide, Regional or General Permit Number(s) Requested: NW 14 3. If this notification is solely a courtesy copy because written approval for the 401 Certification is not required, check here: ? 4. If payment into the North Carolina Ecosystem Enhancement Program (NCEEP) is proposed for mitigation of impacts (verify availability with NCEEP prior to submittal of PCN), complete section VIII and check here: 5. If your project is located in any of North Carolina's twenty coastal counties (listed on page 4), and the project is within a North Carolina Division of Coastal Management Area of Environmental Concern (see the top of page 2 for further details), check here: ? II. Applicant Information 1. Owner/Applicant Information Name: North Carolina Department of Transportation (NCDOT) Mailing Address: 191 Robbinsville Road Andrews. NC 28901 Telephone Number: 828.321.4105 Fax Number: 828.321.3228 E-mail Address: ibdeytonLadot.state. nc.us 2. Agent Information (A signed and dated copy of the Agent Authorization letter must be attached if the Agent has signatory authority for the owner/applicant.) Name: Joshua B. Deyton, P.E. Company Affiliation: County Maintenance Engineer Mailing?Address: (same as above) Telephone Number: Fax Number: Page 2 E-mail Address:_ III. Project Information Attach a vicinity map clearly showing the location of the property with respect to local landmarks such as towns, rivers, and roads. Also provide a detailed site plan showing property boundaries and development plans in relation to surrounding properties. Both the vicinity map and site plan must include a scale and north arrow. The specific footprints of all buildings, impervious surfaces, or other facilities must be included. If possible, the maps and plans should include the appropriate USGS Topographic Quad Map and NRCS Soil Survey with the property boundaries outlined. Plan drawings, or other maps may be included at the applicant's discretion, so long as the property is clearly defined. For administrative and distribution purposes, the USACE requires information to be submitted on sheets no larger than 11 by 17-inch format; however, DWQ may accept paperwork of any size. DWQ prefers full-size construction drawings rather than a sequential sheet version of the full-size plans. If full-size plans are reduced to a small scale such that the final version is illegible, the applicant will be informed that the project has been placed on hold until decipherable maps are provided. 1. Name of project: Stiwinter Mountain Road. SR 1588 2. T.I.P. Project Number or State Project Number (NCDOT Only): 14C.056099 3. Property Identification Number (Tax PIN) N/A 4. Location County: Macon Nearest Town: Franklin Subdivision name (include phase/lot number): N/A Directions to site (include road numbers, landmarks, etc.): From Franklin, take US 64%'28 southeast to SR 1533, Walnut Creek Road. Turn left onto Walnut Creek and continue for annroximately 4 miles to SR 1588. Stiwinter Mountain Road. See attached vicinity man. 5. Site coordinates, if available (UTM or Lat/Long): Site 1 - 35.1719 N 83.2544° W. Site IA - 35.1669° N 83.2531°W. Site ..2 - 35.1764° N 83.2572° W (Note - If project is linear, such as a road or utility line, attach a sheet that separately lists the coordinates for each crossing of a distinct waterbody.) 6. Property size (acres): 0.98 7. Nearest body of water (stream/river/sound/ocean/lake): Walnut Creek (C tr River Basin: Little Tennessee ver basins. The (Note this must be one of North Carolina's seventeen designated major ri River Basin map is available at http://h2o.enr.state.nc.us/admin/maps/.) 9. Describe the existing conditions on the site and general land use in the vicinity of the project at the time of this application: forest and light residential Page 3 10. Describe the overall project in detail, including the type of equipment to be used: The road will be widened by clearing= grubbing, cutting and filling. Necessary drainage will be installed. Necessary drainage pipe will be installed and two culverts will be extended. A roadside seep will be relocated. The road will then be graded and paved. The work will be performed using hydraulic excavator, backhoes, loader, dozer. wheel loader, motor grader. dump trucks and hand tools. 11. Explain the purpose of the proposed work: To improve the secondary road by widening and paving to bring the road to current secondary road standards. IV. Prior Project History If jurisdictional determinations and/or permits have been requested and/or obtained for this project (including all prior phases of the same subdivision) in the past, please explain. Include the USACE Action ID Number, DWQ Project Number, application date, and date permits and certifications were issued or withdrawn. Provide photocopies of previously issued permits, certifications or other useful information. Describe previously approved wetland, stream and buffer impacts, along with associated mitigation (where applicable). If this is a NCDOT project, list and describe permits issued for prior segments of the same T.I.P. project, along with construction schedules. N/A V. Future Project Plans Are any future permit requests anticipated for this project? If so, describe the anticipated work, and provide justification for the exclusion of this work from the current application. None anticipated at this time. VI. Proposed Impacts to Waters of the United States/Waters of the State It is the applicant's (or agent's) responsibility to determine, delineate and map all impacts to wetlands, open water, and stream channels associated with the project. The applicant must also provide justification for these impacts in Section VII below. All proposed impacts, permanent and temporary, must be listed herein, and must be clearly identifiable on an accompanying site plan. All wetlands and waters, and all streams (intermittent and perennial) must be shown on a delineation map, whether or not impacts are proposed to these systems. Wetland and stream evaluation and delineation forms should be included as appropriate. Photographs may be included at& applicant's discretion. If this proposed impact is strictly for wetland or stream mitigation,'list and describe the impact in Section VIII below. If additional space is needed for listing or description, please attach a separate sheet. Page 4 1. Provide a written description of the proposed impacts: Two culverts will be extended in small unnamed tributaries of Walnut Creek. Additionally, 182 feet of roadside seep will be moved away from the road to gain the necessary road width. 2. Individually list wetland impacts below: Wetland Impact Site Number (indicate on map) Type of Impact* Area of Impact (acres) Located within 100-year Floodplain** (yes/no) Distance to Nearest Stream (linear feet) Type of Wetland*** N/A * List each impact separately and identify temporary impacts. Impacts include, but are not limited to: mechanized clearing, grading, till, excavation, flooding, ditching/drainage, etc. For dams, separately list impacts due to both structure and flooding. ** 100-Year floodplains are identified through the Federal Emergency Management Agency's (FEMA) Flood Insurance Rate Maps (FIRM), or FEMA-approved local floodplain maps. Maps are available through the FEMA Map Service Center at 1-800-358-9616, or online at http:, www.fema.eov. *** List a wetland type that best describes wetland to be impacted (e.g., freshwater/ saltwater marsh, forested wetland, beaver pond, Carolina Bay, boa, etc.) Indicate if wetland is isolated (detennination of isolation to be made by USAGE only). List the total acreage (estimated) of all existing wetlands on the property: N/A Total area of wetland impact proposed: N/A 3. Individually list all intermittent and perennial stream impacts below: Stream Impact Site Number (indicate on map) Type of Impact* Length of ? Impact (linear feet) Stream Name** Average Width of Stream Before Impact Perennial or Intermittent'? (please specify) Site #?lA Roadside Seep (Relocation) 182 feet (Temporary) UT to walnut Creek 1' P Site 1 Culvert 10 feet UT to Walnut Creek I' P Site #2 Culvert 25 feet UT to Walnut Creek 0.5' P List each impact separately and identify temporary impacts. Impacts include, but are not limited to: culverts and associated rip-rap, dams (separately list impacts due to both structure and flooding), relocation (include linear feet before and after, and net loss/gain), stabilization activities (cement wall, rip-rap, crib wall, gabions, etc.), excavation, ditch i ng/straightenin a, etc. If stream relocation is proposed, plans and profiles showing the linear footprint for both the original and relocated streams must be included. ** Stream names can be found on USGS topographic maps. If a stream has no name, list as UT (unnamed tributary) to the nearest downstream names} stream into which it flows. USGS maps are available through the USGS at 1-800-358-9616, or online at www.us-s.gov. !4everal intemet sites also allow direct download and printing of USGS maps (e.g., Nww.topozone.com, www.mapquest.com, etc.). Cumulative impacts (linear distance in feet) to all streams on site: 35 Permanent 182 Relocation Page 5 4. Individually list all open water impacts (including lakes, ponds, estuaries, sounds, Atlantic Ocean and any other water of the U.S.) below: Open Water Impact Site Number (indicate on map) Type of Impact* Area of Impact (acres) Name Wat) (if applicable) Type of Waterbody (lake, pond, estuary, sound, bay, ocean, etc.) N/A * List each impact separately and identify temporary impacts. Impacts include, but are not limited to: till, excavation, dredging, flooding, drainage, bulkheads, etc. 5. Pond Creation If construction of a pond is proposed, associated wetland and stream impacts should be included above in the wetland and stream impact sections. Also, the proposed pond should be described here and illustrated on any maps included with this application. Pond to be created in (check all that apply): ? uplands ? stream ? wetlands Describe the method of construction (e.g., dam/embankment, excavation, installation of draw-down valve or spillway, etc.): N/A Proposed use or purpose of pond (e.g., livestock watering, irrigation, aesthetic, trout pond, local stormwater requirement, etc.): N/A Size of watershed draining to pond: N/A Expected pond surface area: N/A VII. Impact Justification (Avoidance and Minimization) Specifically describe measures taken to avoid the proposed impacts. It may be useful to provide information related to site constraints such as topography, building ordinances, accessibility, and financial viability of the project. The applicant may attach drawings of alternative, lower-impact site layouts, and explain why these design options were not feasible. Also discuss how impacts were minimized once the desired site plan was developed. If applicable, discuss construction techniques to be followed during construction to reduce impacts. Minimal lengths of pipe were used to achieve the minimum design widths for secondary roadways in North Carolina. A roadside seep is being moved to prevent any net loss of channel. VIII. Mitigation DWQ - In;, accordance with 15A NCAC 2H .0500, mitigation may be required by the NC Division of Water Quality for projects involving greater than or equal to one acre of impacts to freshwater wetlands or greater than or equal to 150 linear feet of total impacts to perennial streams. Page 6 USACE - In accordance with the Final Notice of Issuance and Modification of Nationwide Permits, published in the Federal Register on March 9, 2000, mitigation will be required when necessary to ensure that adverse effects to the aquatic environment are minimal. Factors including size and type of proposed impact and function and relative value of the impacted aquatic resource will be considered in determining acceptability of appropriate and practicable mitigation as proposed. Examples of mitigation that may be appropriate and practicable include, but are not limited to: reducing the size of the project; establishing and maintaining wetland and/or upland vegetated buffers to protect open waters such as streams; and replacing losses of aquatic resource functions and values by creating, restoring, enhancing, or preserving similar functions and values, preferable in the same watershed. If mitigation is required for this project, a copy of the mitigation plan must be attached in order for USACE or DWQ to consider the application complete for processing. Any application lacking a required mitigation plan or NCEEP concurrence shall be placed on hold as incomplete. An applicant may also choose to review the current guidelines for stream restoration in DWQ's Draft Technical Guide for Stream Work in North Carolina, available at http:/ih2o.enr.state.ne.us/ncwetlands/strm!alde.html. Provide a brief description of the proposed mitigation plan. The description should provide as much information as possible, including, but not limited to: site location (attach directions and/or map, if offsite), affected stream and river basin, type and amount (acreage/linear feet) of mitigation proposed (restoration, enhancement, creation, or preservation), a plan view, preservation mechanism (e.g., deed restrictions, conservation easement, etc.), and a description of the current site conditions and proposed method of construction. Please attach a separate sheet if more space is needed. N/A 2. Mitigation may also be made by payment into the North Carolina Ecosystem Enhancement Program (NCEEP). Please note it is the applicant's responsibility to contact the NCEEP at (919) 715-0476 to determine availability and to request written approval of mitigation prior to submittal of a PCN. For additional information regarding the application process for the NCEEP, check the NCEEP website at http://www.nee!?p.net. If use of the NCEEP is proposed, please check the appropriate box on page three and provide the following information: Amount of stream mitigation requested (linear feet): 35 Amount of buffer mitigation requested (square feet): N/A Amount of Riparian wetland mitigation requested (acres): N/A Amount of Non-riparian wetland mitigation requested (acres): N/A Aniount of Coastal wetland mitigation requested (acres): N/A IX. Environmental Documentation (required by DWQ) Page 7 Does the project involve an expenditure of public (federal/state) funds or the use of public (federal/state) land? Yes ® No ? If yes, does the project require preparation of an environmental document pursuant to the requirements of the National or North Carolina Environmental Policy Act (NEPA/SEPA)? Note: If you are not sure whether a NEPA/SEPA document is required, call the SEPA coordinator at (919) 733-5083 to review current thresholds for environmental documentation. Yes ? No If yes, has the document review been finalized by the State Clearinghouse? If so, please attach a copy of the NEPA or SEPA final approval letter. Yes ? No ? X. Proposed Impacts on Riparian and Watershed Buffers (required by DWQ) It is the applicant's. (or agent's) responsibility to determine, delineate and map all impacts to required state and local buffers associated with the project. The applicant must also provide justification for these impacts in Section VII above. All proposed impacts must be listed herein, and must be clearly identifiable on the accompanying site plan. All buffers must be shown on a map, whether or not impacts are proposed to the buffers. Correspondence from the DWQ Regional Office may be included as appropriate. Photographs may also be included at the applicant's discretion. Will the project impact protected riparian buffers identified within 15A NCAC 2B .0233 (Neuse), 15A NCAC 2B .0259 (Tar-Pamlico), 15A NCAC 2B .0250 (Randleman Rules and Water Supply Buffer Requirements), or other (please identify N/A )? Yes ? No ® If you answered "yes'' provide the following information: Identify the square feet and acreage of impact to each zone of the riparian buffers. If buffer mitigation is required calculate the required amount of mitigation by applying the buffer multipliers. Zone* Impact (square feet) Multiplier Required Mitigation 1 3 2 1.5 Total * Zone I extends out 30 feet perpendicular from near bank of channel; Zone 2 extends an additional 20 feet from the edge of Zone 1. If buffer mitigation is required, please discuss what type of mitigation is proposed (i.e., Donation of Propert y, Conservation Easement, Riparian Buffer Restoration / Enhancement, Preservation or Payment into the Riparian Buffer Restoration Fund). Please attach all appropriate information as identified within 15A NCAC 2B.0242 or.0260. N/A Page 8 XI. Stormwater (required by DWQ) Describe impervious acreage (both existing and proposed) versus total acreage on the site. Discuss stormwater controls proposed in order to protect surface waters and wetlands downstream from the property. The existing compacted gravel roadway acts as an impervious surface. Paving of the roadway should eliminate sedimentation from fines associated with gravel surface treatment. The roadway surface will be approximately 40% of the right-of-way area. Storm water will be diverted through settling basins lined with filtering stone or grass lined buffers prior to entering streams. (See erosion control plan). XII. Sewage Disposal (required by DWQ) Clearly detail the ultimate treatment methods and disposition (non-discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. N/A XIII. Violations (required by DWQ) Is this site in violation of DWQ Wetland Rules (I 5A NCAC 2H .0500) or any Buffer Rules? Yes ? No Is this an after-the-fact permit application? Yes ? No XIV. Other Circumstances (Optional): It is the applicant's responsibility to submit the application sufficiently in advance of desired construction dates to allow processing time for these permits. However, an applicant may choose to list constraints associated with construction or sequencing that may impose limits on work schedules (e.g., draw-down schedules for lakes, dates associated with Endangered and Threatened Species, accessibility problems, or other issues outside of the applicant's control). N/A May 11, 2006 Applicant/Agent's Signature Date (Agent's signature is valid only if an authorization letter from -the applicant is provided.) Page 9 cn pc? e--h CD e--f- ?.J c-i- n Vl 00 00 I's e--1- O N et ?0 x-6.1 ct 0 OC) 00 r-? Q? F-? r-1 4-j N r--a IZ c? O . r, ct O N 00 00 O N N 4J N N SR 1588 1533 53 j 200 HOGBACK MTN° I ELEV. 4,950 9 3 533 `-2 1 3 04 /,-1 566 ' - r1, ti 2.6 1677 -ciu, ? Gneiss U. =1672 4 2 5 4?50 153 U, f 10 ? 64 WS A&A &A 1 674 11 95 -= SKY-HI Y_-- ,1 x - - 1 679 r. - - C11 0 ` - CAMP - 7 rn n 1 `7 A i I i s I i I I I I !i l ', I ! i V / V / ?lJ C7 ? D - o ? z o c-) z co C/) D ? o 00 m m o ? ? -? - - - - - - -< FT 171 o D z ? o C ID