Loading...
HomeMy WebLinkAbout20060637 Ver 1_COMPLETE FILE_20060412 1•- o stem n n PROGRAM INVOICE Atlantic Seawinds Communications 620 Whiteville Rd NW Shallotte, NC 28459 o lp - o to 3r) June 12, 2006 DWQ#: N/A COE#: 200600849 Project: Wet Ash Swamp Cell Tower County: Brunswick ?' I You have elected to satisfy the compensatory mitigation requirements of the Section 401/404 permit issued for the above reference project through payment of a fee to the North Carolina Ecosystem Enhancement Program. In accordance with 15A NCAC 2H.0500, your fee has been calculated as follows (Please note: payment of wetlands is calculated in increments of 0.25 acres). If you have any questions concerning this payment, please call Chris Mankoff at 919-716-1921. Riparian Wetlands 0 acres x $ 26,246.00 = $ Non-Riparian Wetlands 0.25 acres x $ 13,123.00 = $ $3 280 75 Saltwater Wetland 0 acres x $131,230.00 = , . $ Stream 0 linear feet x $ 219.00 = $ Buffer -Zone 1 0 square feet x $ .96 = $ Buffer - Zone 2 0 square feet x $ .96 = $ Total amount of payment $ 3,280.75 Please mail a copy of this invoice with a check made payable to: NC DENR Ecosystem Enhancement Program 1652 Mail Service Center Raleigh, NC 27699-1652 Please call 919-716-1921 for an overnight mailing address or for an appointment to hand deliver the payment. Please note that a payment made to the NC Ecosystem Enhancement Program is not reimbursable unless a request for reimbursement is received within 12 months of the date of the receipt. Any such request must be accompanied by letters from the permitting agencies stating that the permit and/or authorization have been rescinded. YOU MUST BE IN POSSESSION OF THE PAYMENT RECEIPT FROM THE NC ECOSYSTEM ENHANCEMENT PROGRAM PROIR TO COMMENCING THE ACTIVITIES AUTHORIZED BY THE DEPARTMENT OF ARMY PERMIT AND/OR THE 401 WATER QUALITY CERTIFICATION. cc: Cyndi Karoly, Wetlands/401 Unit Scott Jones, USACE - Washington Kyle Barnes, DWQ Regional Office - Washington Doug Huggett, Division of Coastal Management - Morehead City File r L" tv ot Pro ? P/ ?rETIt°e} ` i `i •• , „; i _i?Bft""CN NCDENR North Carolina Ecosystem Enhancement Program, 1652 Mail Service Center, Raleigh, NC 27699-1652 / 919-715-0476 / www.nceep.net Eco stem ? E r d x i PROGRAM April 18, 2006 Tyler McEwen Kimley-Horn & Associates 3001 Weston Parkway Cary, NC 27513 Project: Wet Ashe Swamp County: Brunswick APR 2 ZUiiS tYETL/0„rENRbVV 7C??',=y?yT??iRt';t?CN The purpose of this letter is to notify you that the North Carolina Ecosystem Enhancement Program (NC EEP) is willing to accept payment for impacts associated with the above referenced project. Please note that this decision does not assure that the payment will be approved by the permit issuing agencies as mitigation for project impacts. It is the responsibility of the applicant to contact these agencies to determine if payment to the NC EEP will be approved. This acceptance is valid for six months from the date of this letter. If we have not received a copy of the issued 404 Permit/401 Certification within this time frame, this acceptance will expire. It is the applicant's responsibility to send copies of the 404/401/CAMA permits to NC EEP. Once NC EEP receives a copy of the 404 Permit and/or the 401 Certification an invoice will be issued and payment must be made. Based on the information supplied by you the impacts that may require compensatory mitigation are summarized in the following table. River Basin Wetlands Stream Buffer Buffer Cataloging (Acres) (Linear Feet) Zone 1 Zone 2 Unit (Sq. Ft.) (Sq. Ft.) Riparian on-Riparian Coastal Marsh Cold Cool Warm Cape Fear 0.04 0.04 0 0 0 0 0 0 03030002 Upon receipt of payment, EEP will take responsibility for providing the compensatory mitigation for the permitted impacts up to a 2:1 ratio (buffers, Zone 1 at a 3:1 ratio and Zone 2 at a 1.5:1 ratio). The type and amount of the compensatory mitigation will be as specified in the Section 404 Permit and/or 401 Water Quality Certification, and/or CAMA Permit. The mitigation will be performed in accordance with the Memorandum of Understanding between the N. C. Department of Environment and Natural Resources and the U. S. Army Corps of Engineers dated November 4, 1998. If you have any questions or need additional information, please contact Chris Mankoff at (919) 716-1921 Sin ly, ? • if ?ojL William D. Gilmore, PE Director cc: Cyndi Karoly, Wetlands/401 Unit Tom Farrell USACE-Wilmington Noelle Lutheran, DWQ-Wilmington Doug Huggett, DCM-Morehead City File R?stoY' ... E ... Protect' our sta,& dCDE © ENR North Carolina Ecosystem Enhancement Program, 1652 Mail Service Center, Raleigh, NC 27699-1652 / 919-715-0476 / www.nceep.net r ? v4viii PROGRAM RECEIPT Atlantic Telephone Membership Corporation P O Box 3198 Shallotte, NC 28459 JUL ? 8 2006 W 4 July 12, 2006 r ?? DWQ #: n/a pt 1J`? -CP COE #: 200600849 "Ov-51 Project: Wet Ash Swamp Cell Tower County: Brunswick The North Carolina Ecosystem Enhancement Program (NC EEP) has received a check in the amount of $3,280.75, included in check number 152718, as payment for the compensatory mitigation requirements of the 401 Water Quality Certification and/or US Army Corps of Engineers 404 and/or Division of Coastal Management CAMA permit(s) issued for the above referenced project. This receipt serves as notification that the compensatory mitigation requirements accepted by NC EEP for this project have been satisfied. Please note that you must also comply with all other conditions of the certification/permit(s) including any additional mitigation conditions not accepted by NC EEP and any other state, federal or local government permits or authorization associated with this activity. The NC EEP, by acceptance of this payment, acknowledges that the NC EEP is responsible and agrees to provide the compensatory mitigation requirements as indicated in the table below. The mitigation will be performed in accordance with the Memorandum of Understanding between the NC Department of Environment and Natural Resources and the US Army Corps of Engineers dated November 4, 1998. Catalo in Wetlands (credits) Stream (credits) River Basin g g Unit Riparian Non- Riparian Coastal Marsh Cold Cool Warm Buffer (sq. ft.) Lumber 03040206 0 0.04 0 0 0 0 0 Please note that a payment made to the Ecosystem Enhancement Program is not reimbursable unless a request for reimbursement is received within 12 months of the date of the receipt. Any such request must also be accompanied by letters from the permitting agencies stating that the permit and/or authorization have been rescinded. If you have any questions or need additional information, please contact David Robinson at (919) 715-5835. Sincerely, William D. Gilmore, PE Director cc: Cyndi Karoly, Wetlands/401 Unit Tom Farrell, USACE - Wilmington Noelle Lutheran, DWQ Regional Office - Wilmington Doug Huggett, DCM_Morehead City File k torus... ... Prot" our -t&& WDENR North Carolina Ecosystem Enhancement Program, 1652 Mail Service Center, Raleigh, NC 27699-1652 / 919-715-0476 / www.nceep.net OF WATER Michael F. Easley, Governor p William G. Ross Jr., Secretary p North Carolina Department of Environment and Natural Resources > Alan W. Klimek P.E., Director p -? Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality May 19, 2006 Mr. William Woodward, General Manger/CEO Atlantic Seawinds Communications, LLC 620 Whiteville Road NW Shallotte, NC 28459 Subject: General 401 Water Quality Certification #3374 Wet Ashe Swamp DWQ Project #060637 Brunswick County Dear Mr. Woodward: MAY 2 4 2006 DENR - WATER QUALITY WMMDS AND STOR0XTER BWCH Please replace this letter with the letter dated May 15, 2006. The Wilmington Regional Office received your application for a Nationwide 12 Permit from the US Army Corps of Engineers (USACE) and a General 401 Water Quality Certification on April 12, 2006. The wetland impacts proposed are for the purpose of constructing a guyed cell tower. You are authorized to impact 0.019 acres of Section 404 Wetlands under General Water Quality Certification (WQC) #3374 (enclosed). This Certification can be found on line at: http://h2o.enr.state.nc.us/ncwetlands/certs.html. This Certification allows you to use the Nationwide 12 Permit when the USACE issues it. Written concurrence from the Division of Water Quality (DWQ) is not required provided that you can meet all of the conditions of the General 401 Water Quality Certification. If at anytime during construction of your project you determine that you cannot meet these conditions or if there are any additional impacts to wetlands or water quality not described in your application, you must contact this office immediately. If you have any questions concerning this matter, please do not hesitate to call me at (910)-796-7215. Sincerely, Noelle Lutheran Environmental Specialist III Enclosure: WQC #3374 cc: Tyler McEwen, Kimley-Horn and Associates, Inc. Ian McMillan, 401 Oversight Unit Thomas Farrell, USACE Wilmington N. C. Division of Water Quality 127 Cardinal Drive Extension (910) 395-3900 Customer Service Wilmington Regional Office Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 ne An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper o Carolina atimallry WQC #3374 UTILITY LINE BACKFILL AND BEDDING CERTIFICATION GENERAL CERTIFICATION FOR PROJECTS ELIGIBLE FOR CORPS OF ENGINEERS NATIONWIDE PERMIT NUMBER 12 OR REGIONAL PERMIT 198100049 (UTILITY LINE BACKFILL AND BEDDING) AND RIPARIAN AREA PROTECTION RULES (BUFFER RULES) This General Certification is issued in conformity with the requirements of Section 401, Public Laws 92-500 and 95-217 of the United States and subject to the North Carolina Division of Water Quality (DWQ) Regulations in 15A NCAC 2H, Section .0500 and 15A NCAC 2B .0200 for the discharge of fill material to waters and wetland areas as described in 33 CFR 330 Appendix A (B) (12) and General Permit No. 198100049 of the Corps of Engineers regulations (i.e., including any fill activity for utility line backfill and bedding) and for the Riparian Area Protection Rules (Buffer Rules) in 15A NCAC 2B .0200. This certification replaces Water Quality Certification (WQC) Number 2664 issued on January 21, 1992, Water Quality Certification Number 3022 issued on September 6, 1995, Water Quality Certification (WQC) Number 3101 issued on February 11, 1997 and Water Quality Certification Number 3288 issued on June 1, 2000. This WQC is rescinded when the Corps of Engineers reauthorize Nationwide 12 or Regional Permit 198100049 or when deemed appropriate by the Director of the Division of Water Quality. The State of North Carolina certifies that the specified category of activity will not violate applicable portions of Sections 301, 302, 303, 306 and 307 of the Public Laws 92-500 and 95-217 if conducted in accordance with the conditions hereinafter set forth. Conditions of Certification: 1. Activities covered by this General Certification do not require written concurrence from the Division of Water Quality as long as they comply with all conditions of this General Certification and the conditions of Nationwide 12 or Regional Permit 198100049 as appropriate. If any condition in this Certification cannot be met, application to and written concurrence from DWQ are required. Also, Condition No. 6 is applicable to all streams in basins with riparian area protection rules; 2. In accordance with North Carolina General Statute Section 143-215.3D(e), any request for written concurrence for a 401 Water Quality Certification must include the appropriate fee. If a project also requires a CAMA Permit, one payment to both agencies shall be submitted and will be the higher of the two fees; 3. In accordance with 15A NCAC 2H .0506 (h) compensatory mitigation may be required for stream and/or wetland impacts. Streamside buffer mitigation may be required for any project with Buffer Rules in effect at the time of application for buffer impacts resulting from activities classified as "allowable with mitigation" within the "Table of Uses" section of the Buffer Rules or require a variance under the Buffer Rules. A determination of buffer, wetland and stream mitigation requirements shall be made by DWQ for any Certification involving written concurrences including those for relevant Buffer Rules; 4. The edge of the construction corridor shall not be installed parallel to and closer than 10 feet (3 meters) to a stream and 25 feet in waters classified as HQW. Utility lines shall not cross a stream channel at other than a near-perpendicular direction (i.e., stream channel crossings shall not be at an angle of less than 75 degrees or more than 105 degrees to the stream bank); WQC #3374 5. Any wastewater line that crosses any stream shown on the most recent version of the 1:24,000 USGS topographic map or NRCS (SCS) County Soil Survey as permanent or intermittent shall be installed with no joints connected within the footprint of a stream channel or within 2 feet of the stream banks. Otherwise, written concurrence from DWQ is required; 6. Impacts to any stream length in the Neuse, Tar-Pamlico, Randleman and Catawba River Basins (or any other river basins with Buffer Rules in effect at the time of application) requires written concurrence from DWQ in accordance with 15A NCAC 2B.0233,.0259, .0250 and .0243. Activities listed as "exempt" from these rules do not need to apply for written concurrence under this Certification. New development activities located in the protected 50-foot wide riparian areas (whether jurisdictional wetlands or not) within the Neuse, Tar-Pamlico and Randleman River Basins shall be limited to "uses" identified within and constructed in accordance with 15A NCAC 2B .0233-0259-0250 and .0243. All new development shall be located, designed, constructed, and maintained to have minimal disturbance to protect water quality to the maximum extent practicable through the use of best management practices; 7. Measures shall be taken to prevent live or fresh concrete from coming into contact with waters of the state until the concrete has hardened; 8. Herbicides can be applied in wetlands or other waters only when applied by a certified applicator, and in strict accordance with product labeling; 9. Placement of rip rap is restricted to the stream bottom and banks directly impacted by the placement of the utility line. Rip. rap may only be used below the normal high water level. The stream cross section must be restored to its original grade and elevation. Placement of rip rap or other materials shall not result in de-stabilization of the stream bed or banks upstream of downstream of the crossing; 10. That appropriate sediment and erosion control practices which equal or exceed those outlined in the most recent version of the "North Carolina Sediment and Erosion Control Planning and Design Manual' or the "North Carolina Surface Mining Manual" whichever is more appropriate (available from the Division of Land Resources (DLR) in the DENR Regional or Central Offices) shall be in full compliance with all specifications governing the proper design, installation and operation and maintenance of such Best Management Practices in order to assure compliance with the appropriate turbidity water quality standard; 11. All sediment and erosion control measures placed in wetlands or waters shall be removed and the original grade restored within two months after the Division of Land Resources has released the project; 12. Annual native species suitable for wet locations shall be planted and established within jurisdictional wetlands for soil and erosion control. Perennials such as fescue are prohibited; 13. No fertilizer shall be applied within 10 feet (3 meters) of streams. Any fertilizer application must comply with all other Federal, State and Local regulations; 14. The construction corridor (including access roads and stockpiling of materials) is limited to 40 feet (12.2 meters) in width in wetlands and across stream channels and must be minimized to the maximum extent practicable; WQC #3374 15. Permanent, maintained access corridors shall be restricted to the minimum width practicable and shall not exceed 10 feet (3 meters) in width except at manhole locations. A 10 feet (3 meters) by 10 feet (3 meters) perpendicular vehicle turnaround must be spaced at least 500 feet (152.4 meters) apart. Written concurrence is required if the maintenance corridor is greater than 10 feet (3 meters) wide except that a maintenance corridor larger than ten feet is acceptable for gas pipelines as long as mitigation is provided for additional wetland fills to the maintenance corridor beyond those widths specified in this General Certification; 16. An anti-seep collar shall be placed at the downstream (utility line gradient) wetland boundary and every 150 feet (45.7 meters) up the gradient until the utility exits the wetland for buried utility lines. Anti-seep collars may be constructed with class B concrete, compacted clay, PVC pipe, or metal collars. Wetland crossings that are directionally drilled, and perpendicular wetland crossings that are open cut and less than 150 feet (45.7 meters) long do not require anti-seep collars. The compacted clay shall have a specific discharge of 1 X 10- 5 cm/sec or less. A section and plan view diagram is attached for the anti-seep collars; The following specifications shall apply to class B concrete: a) Minimum cement content, sacks per cubic yard with rounded course aggregate 5.0 b) Minimum cement content, sacks per cubic yard with angular course aggregate 5.5 c) Maximum water-cement ratio gallons per sack 6.8 d) Slump range 2" to 4" e) Minimum strength - 28 day psi 2,500 17. This General Certification does not authorize any permanent changes in pre-construction elevation contours in waters or wetlands or stream dimension, pattern or profile. The permittee will have a specific plan for restoring wetland contours. Any excess material will be removed to a high ground disposal area; 18. If an environmental document is required, this Certification is not valid until a Finding of No Significant Impact (FONSI) or Record of Decision (ROD) is issued by the State Clearinghouse; 19. Stormwater management will not be required for this Certification as long as all other Conditions are met. However, in the twenty coastal counties, the appropriate DWQ Regional Office must be contacted to determine if Coastal Stormwater Regulations still apply; 20. Compensatory mitigation (i.e., restoration, creation or preservation) for wetland losses will not be required for this Certification if written concurrence is not needed; 21. Payment of a dollar per acre figure into the Wetland Restoration Program for these impacts is acceptable when compensatory mitigation is required as long as the Wetlands Restoration Program agrees in writing to accept this payment. Other mitigation plans must receive written DWQ concurrence; 22. This Certification does not relieve the applicant of the responsibility to obtain all other required Federal, State or local approvals; 23. Additional site-specific conditions may be added to projects for which written concurrence is required or requested under this Certification in order to ensure compliance with all applicable water quality and effluent standards; WQC #3374 24. Concurrence from DWQ that this Certification applies to an individual project shall expire three years from the date of the cover letter from DWQ or on the same day as the expiration date of the corresponding Nationwide Permit 12 or Regional Permit 198100049 whichever is sooner; 25. When written concurrence is required, the applicant is required to use the most recent version of the Certification of Completion form to notify DWQ when all work included in the 401 Certification has been completed. Non-compliance with or violation of the conditions herein set forth by a specific fill project may result in revocation of this Certification for the project and may also result in criminal and/or civil penalties. The Director of the North Carolina Division of Water Quality may require submission of a formal application for individual certification for any project in this category of activity that requires written concurrence under this certification, if it is determined that the project is likely to have a significant adverse effect upon water quality or degrade the waters so that existing uses of the wetland or downstream waters are precluded. Public hearings may be held for specific applications or group of applications prior to a certification decision if deemed in the public's best interest by the Director of the North Carolina Division of Water Quality. Effective date: 18 March 2002 DIVISION OF WATER QUALITY By Gregory J. Thorpe, Ph.D. Acting Director WQC # 3374 4 i WQC #3374 Winches .- Utii[tj7Lirrr? ` {Diamater varies 1 1 ICKot C Class 8 Concrete or Compacted Clay _?6 I 6 inches reach Width G Inphes Not to exceed 40 feet sgcmoN 'Gass B Concrete or Camp red. Clay i 12 aches PLAN- 5 Subject: Wet Ashe Swamp From: Bev Strickland <bev.strickland@ncmail.net> Date: Fri, 19 May 2006 11:25:52 -0400 To: Noelle Lutheran <Noelle.Lutheran@ncmail.net> The letter you issued for Wet Ashe Swamp, DWQ # 060637 has the wrong county listed. Could you please reissue the letter with the corrected county listed. Thanks Bev C r Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality May 15, 2006 Mr. William Woodward, General Manger/CEO Atlantic Seawinds Communications, LLC 620 Whiteville Road NW Shallotte, NC 28459 Subject: General 401 Water Quality Certification #3374 Wet Ashe Swamp DWQ Project #060637 New Hanover County Dear Mr. Woodward: The Wilmington Regional Office received your application for a Nationwide 12 Permit from the US Army Corps of Engineers (USACE) and a General 401 Water Quality Certification on April 12, 2006. The wetland impacts proposed are for the purpose of constructing a guyed cell tower. You are authorized to impact 0.019 acres of Section 404 Wetlands under General Water Quality Certification (WQC) #3374 (enclosed). This Certification can be found on line at: htip://h2o.enr.state.nc.us/ncwetlands/certs.html. This Certification allows you to use the Nationwide 12 Permit when the USACE issues it. Written concurrence from the Division of Water Quality (DWQ) is not required provided that you can meet all of the conditions of the General 401 Water Quality Certification. If at anytime during construction of your project you determine that you cannot meet these conditions or if there are any additional impacts to wetlands or water quality not described in your application, you must contact this office immediately. If you have any questions concerning this matter, please do not hesitate to call me at (910)-796-7215. Sincerely, Noelle Lutheran Environmental Specialist III Enclosure: WQC #3374 cc: Tyler McEwen, Kimley-Horn and Associates, Inc. Ian McMillan, 401 Oversight Unit Thomas Farrell, USACE Wilmington MAy 1 9 2006 N. C. Division of Water Quality 127 Cardinal Drive Extension (910) 395-3900 Customer Service Wilmington Regional Office Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper W--?FR North Carolina Naturally WQC #3374 UTILITY LINE BACKFILL AND BEDDING CERTIFICATION GENERAL CERTIFICATION FOR PROJECTS ELIGIBLE FOR CORPS OF ENGINEERS NATIONWIDE PERMIT NUMBER 12 OR REGIONAL PERMIT 198100049 (UTILITY LINE BACKFILL AND BEDDING) AND RIPARIAN AREA PROTECTION RULES (BUFFER RULES) This General Certification is issued in conformity with the requirements of Section 401, Public Laws 92-500 and 95-217 of the United States and subject to the North Carolina Division of Water Quality (DWQ) Regulations in 15A NCAC 2H, Section .0500 and 15A NCAC 2B .0200 for the discharge of fill material to waters and wetland areas as described in 33 CFR 330 Appendix A (B) (12) and General Permit No. 198100049 of the Corps of Engineers regulations (i.e., including any fill activity for utility line backfill and bedding) and for the Riparian Area Protection Rules (Buffer Rules) in 15A NCAC 2B .0200. This certification replaces Water Quality Certification (WQC) Number 2664 issued on January 21, 1992, Water Quality Certification Number 3022 issued on September 6, 1995, Water Quality Certification (WQC) Number 3101 issued on February 11, 1997 and Water Quality Certification Number 3288 issued on June 1, 2000. This WQC is rescinded when the Corps of Engineers reauthorize Nationwide 12 or Regional Permit 198100049 or when deemed appropriate by the Director of the Division of Water Quality. The State of North Carolina certifies that the specified category of activity will not violate applicable portions of Sections 301, 302, 303, 306 and 307 of the Public Laws 92-500 and 95-217 if conducted in accordance with the conditions hereinafter set forth. Conditions of Certification: 1. Activities covered by this General Certification do not require written concurrence from the Division of Water Quality as long as they comply with all conditions of this General Certification and the conditions of Nationwide 12 or Regional Permit 198100049 as appropriate. If any condition in this Certification cannot be met, application to and written concurrence from DWQ are required. Also, Condition No. 6 is applicable to all streams in basins with riparian area protection rules;. 2. In accordance with North Carolina General Statute Section 143-215.3D(e), any request for written concurrence for a 401 Water Quality Certification must include the appropriate fee. If a project also requires a CAMA.Permit, one payment to both agencies shall be submitted and will be the higher of the two fees; 3. In accordance with 15A NCAC 2H .0506 (h) compensatory mitigation may be required for stream and/or wetland impacts. Streamside buffer mitigation may be required for any project with Buffer Rules in effect at the time of application for buffer impacts resulting from activities classified as "allowable with mitigation" within the "Table of Uses" section of the Buffer Rules or require a variance under the Buffer Rules. A determination of buffer, wettand and stream mitigation requirements. shall be made by DWQ for any Certification involving written concurrences including those for relevant Buffer Rules; 4. The edge of the construction corridor shall not be installed parallel to and closer than 10 feet (3 meters) to a stream and 25 feet in waters classified as HQW. Utility lines shall not -cross a stream channel at other than a near-perpendicular direction (i.e., stream channel crossings shall not be at an angle of less than 75 degrees or more than 105 degrees to the stream bank); WQC #3374 5. Any wastewater line that crosses any stream shown on the most recent version of the 1:24,000 USGS topographic map or NRCS (SCS) County Soil Survey as permanent or intermittent shall be installed with no joints connected within the footprint of a stream channel or within 2 feet of the stream banks. Otherwise, written concurrence from DWQ is required; 6. Impacts to any stream length in the Neuse, Tar-Pamlico, Randleman and Catawba River Basins (or any other river basins with Buffer Rules in effect at the time of application) requires written concurrence from DWQ in accordance with 15A NCAC 2B.0233,.0259, .0250 and .0243. Activities listed as "exempt"from these rules do not need to apply for written concurrence under this Certification. New development activities located in the protected 50-foot wide riparian areas (whether jurisdictional wetlands or not) within the Neuse, Tar-Pamlico and Randleman River Basins shall be limited to "uses" identified within and constructed in accordance with 15A NCAC 2B .0233-0259-0250 and .0243. All new development shall be located, designed, constructed, and maintained to have minimal disturbance to protect water quality to the maximum extent practicable through the use of best management practices; 7. Measures shall betaken to prevent live or fresh concrete from coming into contact with waters of the state until the concrete has hardened; 8. Herbicides can be applied in wetlands or other waters only when applied by a certified applicator, and in strict accordance with product labeling; 9. Placement of rip rap is restricted to the stream bottom and banks directly impacted by the placement of the utility line. Rip rap may only be used below the normal high water level. The stream cross section must be restored to its original grade and elevation. Placement of rip rap or other materials shall not result in de-stabilization of the stream bed or banks upstream of downstream of the crossing; 10. That appropriate sediment and erosion control practices which equal or exceed those outlined in the most recent version of the "North Carolina Sediment and Erosion Control Planning and Design Manual" or the "North Carolina Surface Mining Manual" whichever is more appropriate (available. from the Division of Land Resources (DLR) in the DENR Regional or Central Offices) shall be in full compliance with all specifications governing the proper design, installation and operation and maintenance of such Best Management Practices in order to assure compliance with the appropriate turbidity water quality standard; 11. All sediment and erosion control measures placed in wetlands or waters shall be removed and the original grade restored within two months after the Division of Land Resources has released the project; 12. Annual native species suitable for wet locations shall be planted and established within jurisdictional wetlands for soil and erosion control. Perennials such as fescue are prohibited; 13. No fertilizer shall be applied within 10 feet (3 meters) of streams. Any fertilizer application must comply with all other Federal, State and Local regulations; 14. The construction corridor (including access roads and stockpiling of materials) is limited to --4O-fL-et(TZ.2-mG-t-ers)-in widthir wetlands and-across stream channe sand-mustbe minimized to the maximum extent practicable; WQC #3374 15. Permanent, maintained access corridors shall be restricted to the minimum width practicable and shall not exceed 10 feet (3 meters) in width except at manhole locations. A 10 feet (3 meters) by 10 feet (3 meters) perpendicular vehicle turnaround must be spaced at least 500 feet (152.4 meters) apart. Written concurrence is required if the maintenance corridor is greater than 10 feet (3 meters) wide except that a maintenance corridor larger than ten feet is acceptable for gas pipelines as long as mitigation is provided for additional wetland fills to the maintenance corridor beyond those widths specified in this General Certification; 16. An anti-seep collar shall be placed at the downstream (utility line gradient) wetland boundary and every 150 feet (45.7 meters) up the gradient until the utility exits the wetland for buried utility lines. Anti-seep collars may be constructed with class B concrete, compacted clay, PVC pipe, or metal collars. Wetland crossings that are directionally drilled, and perpendicular wetland crossings that are open cut and less than 150 feet (45.7 meters) long do not require anti-seep collars. The compacted clay shall have a specific discharge of 1 X 10- 5 cm/sec or less. A section and plan view diagram is attached for the anti-seep collars; The following specifications shall apply to class B concrete: a) Minimum cement content, sacks per cubic yard with rounded course aggregate 5.0 b) Minimum cement content, sacks per cubic yard with angular course aggregate 5.5 c) . Maximum water-cement ratio gallons per sack 6.8 d) Slump range 2" to 4" e) Minimum strength - 28 day psi 2,500 17. This General Certification does not authorize any permanent changes in pre-construction elevation contours in waters or wetlands or stream dimension, pattern or profile. The permittee will have a specific plan for restoring wetland contours. Any excess material will be removed to a high ground disposal .area; 18. If an environmental document is required, this Certification is not valid until a Finding of No Significant Impact (FONSI) or Record of Decision (ROD) is issued by the State Clearinghouse; 19. Stormwater management will not be required for this Certification as long as all other Conditions are met. However, in the twenty coastal counties, the appropriate DWQ Regional Office must be contacted to determine if Coastal Stormwater Regulations still apply; 20. Compensatory mitigation (i.e., restoration, creation or preservation) for wetland losses will not be required for this Certification if written concurrence is not needed; 21. Payment of a dollar per acre figure into the Wetland Restoration Program for these impacts is acceptable when compensatory mitigation is required as long as the Wetlands Restoration Program agrees in writing to accept this payment. Other mitigation plans must receive written DWQ concurrence; 22. This Certification does not relieve the applicant of the responsibility to obtain all other required Federal, State or local approvals; --23:-Addditional sire=specific conditions maybe adMd-fo projects Jor which written concurrence is required or requested under this Certification in order to ensure compliance with all applicable water quality and effluent standards; WQC #3374 24. Concurrence from DWQ that this Certification applies to an individual project shall expire three years from the date of the cover letter from DWQ or on the same day as the expiration date of the corresponding Nationwide Permit 12 or Regional Permit 198100049 whichever is sooner; 25. When written concurrence is required, the applicant is required to use the most recent version of the Certification of Completion form to notify DWQ when all work included in the 401 Certification has been completed. Non-compliance with or violation of the conditions herein set forth by a specific fill project may result in revocation of this Certification for the project and may also result in criminal and/or civil penalties. The Director of the North Carolina Division of Water Quality may require submission of a formal application for individual certification for any project in this category of activity that requires written concurrence under this certification, if it is determined that the project is likely to have a significant adverse effect upon water quality or degrade the waters so that existing uses of the wetland or downstream waters are precluded. Public hearings may be held for specific applications or group of applications prior to a certification decision if deemed in the public's best interest by the Director of the North Carolina Division of Water Quality. Effective date: 18 March 2002 DIVISION OF WATER QUALITY By Gregory J. Thorpe, Ph.D. Acting Director WQC # 3374 It WQC #3374 -?l 8 i i i nchas Utiht, *Lirtp, (Djameter'Varies) I foot 1 I Class B Concrete or Compacted Clay q t0 inches dth_ rench I 6 Indies Not to exceed 40 feet SECTION Cass Soncrt or Compacted CIay 2 k Inches 6 Inches PLAN 5 Triage Check List Date: 4/19/06 Project Name: West Ashe Swamp-Atlantic Seawinds Com. DWQ#: 06-0637 County: Brunswick j , To: Noelle Lutheran, Wilmington Regional Office 60-Day processing time: 4/12/06 to 6/10/06 From: Cyndi Karoly Telephone: (919) 733-9721 The file attached is being forwarded to you for your evaluation. Please call if you need assistance. ? Stream length impacted ? Stream determination Wetland determination and distance to blue-line surface waters on USFW topo maps ? Minimization/avoidance issues ? Buffer Rules (Meuse, Tar-Pamlico, Catawba, Randleman) ? Pond fill Mitigation Ratios ? Ditching ? Are the stream and or wetland mitigation sites available and viable? ? Check drawings for accuracy Is the application consistent with pre-application meetings? ? Cumulative impact concern Comments: As per our discussion regarding revision of the triage and delegation processes, please review the attached file. Note that you are the first reviewer, so this file will need to be reviewed for administrative as well as technical details. If you elect to place this project on hold,. please ask the applicant to provide your requested information to both the Central Office in Raleigh as well as the Asheville Regional Office. As we discussed, this is an experimental, interim procedure as we slowly transition to electronic applications. Please apprise me of any complications you encounter, whether related to workload, processing times, or lack of a "second reviewer" as the triage process in Central had previously provided. Also, if you think of ways to improve this process, especially so that we can plan for the electronic applications, let me know. Thanks! Office Use Only: Form Version March 05 USACE Action ID No. DWQ No. 2 0 0 8( 3 7 (If any particular item is not applicable to this project, please enter "Not Applicable" or "N/A".) 1. Processing Check all of the approval(s) requested for this project: ® Section 404 Permit ? Riparian or Watershed Buffer Rules ? Section 10 Permit ? Isolated Wetland Permit from DWQ ? 401 Water Quality Certification ? Express 401 Water Quality Certification 2. Nationwide, Regional or General Permit Number(s) Requested: Nationwide 12 3. If this notification is solely a courtesy copy because written approval for the 401 Certification is not required, check here: 4. If payment into the North Carolina Ecosystem Enhancement Program (NCEEP) is proposed for mitigation of impacts, attach the acceptance letter from NCEEP, complete section VIII, and check here: 5. If your project is located in any of North Carolina's twenty coastal counties (listed on page 4), and the project is within a North Carolina Division of Coastal Management Area of Environmental Concern (see the top of page 2 for further details), the o 1}ae: V II. Applicant Information ?55 U APR 1 2 2006 1. Owner/Applicant Information Name: Atlantic Seawinds Communications, LLC DENR - WATER QUALITY WEEP Awe wn eT RMWATee BFW Mailing Address: 620 Whiteville Rd. NW Shallotte NC 28459 Telephone Number: 888-367-2862 Fax Number: E-mail Address: (Website) atmc.net 2. Agent/Consultant Information (A signed and dated copy of the Agent Authorization letter must be attached if the Agent has signatory authority for the owner/applicant.) Name: Tyler McEwen Company Affiliation: Kimley-Horn and Associates, Inc. Mailing Address: 3001 Weston Parkway Cary, NC 27513 Telephone Number: (919) 677-2104 Fax Number: (919) 677-2050 E-mail Address: Tyler.McEwen@kimley-horn.com Updated 11/1/2005 Page 5 of 13 III. Project Information Attach a vicinity map clearly showing the location of the property with respect to local landmarks such as towns, rivers, and roads. Also provide a detailed site plan showing property boundaries and development plans in relation to surrounding properties. Both the vicinity map and site plan must include a scale and north arrow. The specific footprints of all buildings, impervious surfaces, or other facilities must be .included. If possible, the maps and plans should include the appropriate USGS Topographic Quad Map and NRCS Soil Survey with the property boundaries outlined. Plan drawings, or other maps may be included at the applicant's discretion, so long as the property is clearly defined. For administrative and distribution purposes, the USACE requires information to be submitted on sheets no larger than 11 by 17-inch format; however, DWQ may accept paperwork of any size. DWQ prefers full-size construction drawings rather than a sequential sheet version of the full-size plans. If full-size plans are reduced to a small scale such that the final version is illegible, the applicant will be informed that the project has been placed on hold until decipherable maps are provided. 1. Name of project: Wet Ashe Swamp 2. T.I.P. Project Number or State Project Number (NCDOT Only): 3. Property Identification Number (Tax PIN): 014700067 4. Location County: Brunswick Nearest Town: Honey Pond Subdivision name (include phase/lot number): Directions to site (include road numbers/names, landmarks, etc.): From Wilmington take US Highway 17 South. Turn northwest onto NC Highway 130 West, west of Shallotte. Approximately 0.5 mile north of Honey Pond, immediately after you cross Wet Ashe Swamp turn east (right) onto the cell tower gravel entrance road. Site coordinates (For linear projects, such as a road or utility line, attach a sheet that separately lists the coordinates for each crossing of a distinct waterbody.) Decimal Degrees (6 digits minimum): 34.039050 ON 78.502914 °W 6. Property size (acres): 43.00 7. Name of nearest receiving body of water: Wet Ashe Swamp 8. River Basin: Lumber River (Note - this must be one of North Carolina's seventeen designated major river basins. The River Basin map is available at http://h2o.enr.state.nc.us/admin/maps/.) 9. Describe the existing conditions on the site and generalland use in the vicinity of the project at the time of this application: The cell tower site has been constructed. The entrance from NC Highway 130 was constructed at a different location than the construction design drawings provided by Kimley-Horn and Associates,' Inc. (KHA). The cell tower was Updated 11/1/2005 Page 6 of 13 designed to avoid any wetland impacts by locating the cell tower and the entrance road within an existing agricultural field. The entrance of the access road was constructed and impacted a linear wetland adjacent to NC Highway 130.' 10. Describe the overall project in detail, including the type of equipment to be used: The construction was completed using heavy machinerv such as bulldozers, excavators, and cranes Primary construction began with the construction of the construction access/maintenance road. This involved grading and filling. According to the KHA designs, the construction access road was to be located completely within uplands, however the construction road was built and crossed a linear wetland feature. This feature was filled and graded for the entrance area of the construction access road. An 18-inch culvert was inserted to maintain the hydrologic connection. The next phase of the project is to pour the foundation for the M anchor locations the cell tower, the equipment shelter pad, and the generator pad This phase also requires grading of the 60' X 60' fenced compound area and the Uy anchor-locations. The concrete pads are poured from a cement truck. The final phase of erection is the tower. This phase is completed with the use of a crane. 11. Explain the purpose of the proposed work: This guyed cell tower will provide cellular coverage the local public IV. Prior Project History If jurisdictional determinations and/or permits have been requested and/or obtained for this project (including all prior phases of the same subdivision) in the past, please explain. Include the USACE Action ID Number, DWQ Project Number, application date, and date permits and certifications were issued or withdrawn. Provide photocopies of previously issued permits, certifications or other useful information. Describe previously approved wetland, stream and buffer impacts, along with associated mitigation (where applicable). If this is a NCDOT project, list and describe permits issued for prior segments of the same T.I.P. project, along with construction schedules. No previous permits or jurisdictional determinations have been obtained in the past for this project V. Future Project Plans Are any future permit requests anticipated for this project? If so, describe the anticipated work, and provide justification for the exclusion of this work from the current application. No future construction anticipated VI. Proposed Impacts to Waters of the United States/Waters of the State It is the applicant's (or agent's) responsibility to determine, delineate and map all impacts to wetlands, open water, and stream channels associated with the project. Each impact must be listed separately in the tables below (e.g., culvert installation should be listed separately from riprap dissipater pads). Be sure to indicate if an impact is temporary. All proposed impacts, permanent and temporary, must be listed, and must be labeled and clearly identifiable on an Updated 11/1/2005 Page 7 of 13 accompanying site plan. All wetlands and waters, and all streams (intermittent and perennial) should be shown on a delineation map, whether or not impacts are proposed to these systems. Wetland and stream evaluation and delineation forms should be included as appropriate. Photographs may be included at the applicant's discretion. If this proposed impact is strictly for wetland or stream mitigation, list and describe the impact in Section VIII below. If additional space is needed for listing or description, please attach a separate sheet. 1. Provide a written description of the proposed impacts: The construction of the construction access road was not completed as the KHA construction design drawings called for. The access road crosses and impacts approximately 810 square feet (0.019-acre) of a linear wetland feature located adjacent to NC Highway 130. This crossing includes an 18-inch culvert to maintain a hydrologic connection. 2. Individually list wetland impacts. Types of impacts include, but are not limited to mechanized clearing, grading, fill, excavation, flooding, ditching/drainage, etc. For dams, separately list impacts due to both structure and flooding. Wetland Impact Site Number (indicate on map) Type of Impact Type of Wetland (e.g., forested, marsh, herbaceous, bog, etc.) Located within 100-year Floodplain (yes/no) Distance to Nearest Stream linear feet) Area of Impact (acres) 1 Grading/Filling Forested Yes 250 0.019 Total Wetland Impact (acres) 0.019 3. List the total acreage (estimated) of all existing wetlands on the property: 0.125-acres 4. Individually list all intermittent and perennial stream impacts. Be sure to identify temporary impacts. Stream impacts include, but are not limited to placement of fill or culverts, dam construction, flooding, relocation, stabilization activities (e.g., cement walls, rip-rap, crib walls, gabions, etc.), excavation, ditching/straightening, etc. If stream relocation is proposed, plans and profiles showing the linear footprint for both the original and relocated streams must be included. To calculate acreage, multi ly length X width, then divide b 43,560. Stream Impact Number indicate on ma) Stream Name Type of Impact Intermittent. Perennial Intermittent? Average Stream Width Before Impact Impact Length linear feet Area of Impact (acres) Total Stream Impact (by length and acreage) 5. Individually list all open water impacts (including lakes, ponds, estuaries, sounds, Atlantic Ocean and any other water of the U.S.). Open water impacts include, but are not limited to fill, excavation, dredging, flooding, drainage, bulkheads, etc. Updated 11/1/2005 Page 8 of 13 Open Water Impact Site Number (indicate on ma Name of Waterbody (if applicable) Type of Impact Type of Waterbody (lake, pond, estuary, sound, bay, ocean, etc. Area of Impact acres Total Open Water Impact (acres) 6 List the cumulative impact to all Waters of the U.S. resulting from the project Stream Impact (acres): Wetland Impact (acres): 0.019 Open Water Impact (acres): Total Impact to Waters of the U.S. (acres) 0.019 Total Stream Impact (linear feet): 7. Isolated Waters Do any isolated waters exist on the property? ? Yes ® No Describe all impacts to isolated waters, and include the type of water (wetland or stream) and the size of the proposed impact (acres or linear feet). Please note that this section only applies to waters that have specifically been determined to be isolated by the USACE. Pond Creation If construction of a pond is proposed, associated wetland and stream impacts should be included above in the wetland and stream impact sections. Also, the proposed pond should be described here and illustrated on any maps included with this application. Pond to be created in (check all that apply): ? uplands ? stream ? wetlands Describe the method of construction (e.g., dam/embankment, excavation, installation of draw-down valve or spillway, etc.): Proposed use or purpose of pond (e.g., livestock watering, irrigation, aesthetic, trout pond, local stormwater requirement, etc.): Current land use in the vicinity of the pond: Size of watershed draining to pond: Expected pond surface area: VII. Impact Justification (Avoidance and Minimization) Specifically describe measures taken to avoid the proposed impacts. It may be useful to provide information related to site constraints such as topography, building ordinances, accessibility, and financial viability of the project. The applicant may attach drawings of alternative, lower-impact site layouts, and explain why these design options were not feasible. Also discuss how impacts were minimized once the desired site plan was developed. If applicable, discuss construction techniques to be followed during construction to reduce impacts. During construction of guyed tower Atlantic Seawinds Communications, LLC encroached upon a linear wetland by filling and grading approximately 0.019-acre of forested wetland. Atlantic Seawinds Communications LLC agrees to mitigate for all permanent impacts to waters of the Updated 11/1/2005 Page 9 of 13 United States via an In Lieu payment to the North Carolina Ecosystem Enhancement Program (NCEEP) VIII. Mitigation DWQ - In accordance with 15A NCAC 2H .0500, mitigation may be required by the NC Division of Water Quality for projects involving greater than or equal to one acre of impacts to freshwater wetlands or greater than or equal to 150 linear feet of total impacts to perennial streams. USACE - In accordance with the Final Notice of Issuance and Modification of Nationwide Permits, published in the Federal Register on jeanuary 15, 2002, mitigation will be required when necessary to ensure that adverse effects to the aquatic environment are minimal. Factors including size and type of proposed impact and function and relative value of the impacted aquatic resource will be considered in determining acceptability of appropriate and practicable mitigation as proposed. Examples of mitigation that may be appropriate and practicable include, but are not limited to: reducing the size of the project; establishing and maintaining wetland and/or upland vegetated buffers to protect open waters such as streams; and replacing losses of aquatic resource functions and values by creating, restoring, enhancing, or preserving similar functions and values, preferable in the same watershed. If mitigation is required for this project, a copy of the mitigation plan must be attached in order for USACE or DWQ to consider the application complete for processing. Any application lacking a required mitigation plan or NCEEP concurrence shall be placed on hold as incomplete. An applicant may also choose to review the current guidelines for stream restoration in DWQ's Draft Technical Guide for Stream Work in North Carolina, available at http://h2o.enr.state.nc.us/ncwetlands/strmgide.html. 1. Provide a brief description of the proposed mitigation plan. The description should provide as much information as possible, including, but not limited to: site location (attach directions and/or map, if offsite), affected stream and river basin, type and amount (acreage/linear feet) of mitigation proposed (restoration, enhancement, 'creation, or preservation), a plan view, preservation mechanism (e.g., deed restrictions, conservation easement, etc.), and a description of the current site conditions and proposed method of construction. Please attach a separate sheet if more space is needed. Payment to the North Carolina Ecosystem Enhancement Program. 2. Mitigation may also be made by payment into the North Carolina Ecosystem Enhancement Program (NCEEP). Please note it is the applicant's responsibility to contact the NCEEP at (919) 715-0476 to determine availability, and written approval from the NCEEP indicating that they are will to accept payment for the mitigation must be attached to this form. For additional information regarding the application process for the NCEEP, check the NCEEP website at http://h2o.enr.state.nc.us/wm/index.htm. If use of the NCEEP is proposed, please check the appropriate box on page five and provide the following information: Updated 11/1/2005 Page 10 of 13 Amount of stream mitigation requested (linear feet): 'N/A Amount of buffer mitigation requested (square feet): N/A Amount of Riparian wetland mitigation requested (acres): 0.040-acre Amount of Non-riparian wetland mitigation requested (acres): 0.040-acre Amount of Coastal wetland mitigation requested (acres): N/A IX. Environmental Documentation (required by DWQ) 1. Does the project involve an expenditure of public (federal/state/local) funds or the use of public (federal/state) land? Yes ? No 2. If yes, does the project require preparation of an environmental document pursuant to the requirements of the National or North Carolina Environmental Policy Act (NEPA/SEPA)? Note: If you are not sure whether a NEPA/SEPA document is required, call the SEPA coordinator at (919) 733-5083 to review current thresholds for environmental documentation. Yes ? No ? 3. If yes, has the document review been finalized by the State Clearinghouse? If so, please attach a copy of the NEPA or SEPA final approval letter. Yes ? No ? X. Proposed Impacts on Riparian and Watershed Buffers (required by DWQ) It is the applicant's (or agent's) responsibility to determine, delineate and map all impacts to required state and local buffers associated with the project. The applicant must also provide justification for these impacts in Section VII above. All proposed impacts must be listed herein, and must be clearly identifiable on the accompanying site plan. All buffers must be shown on a map, whether or not impacts are proposed to the buffers. Correspondence from the DWQ Regional Office may be included as appropriate. Photographs may also be included at the applicant's discretion. Will the project impact protected riparian buffers identified within 15A NCAC 2B .0233 (Meuse), 15A NCAC 2B .0259 (Tar-Pamlico), 15A NCAC 02B .0243 (Catawba) 15A NCAC 2B .0250 (Randleman Rules and Water Supply Buffer Requirements), or other (please identify V Yes ? No 2. If "yes", identify the square feet and acreage of impact to each zone of the riparian buffers. If buffer mitigation is required calculate the required amount of mitigation by applying the buffer multipliers. Impact Required Zone* Multiplier A4;*;-t;- 3 (2 for Catawba) 1.5 Total I I * Zone 1 extends out 30 feet perpendicular from the top of the near bank of channel; Zone 2 extends an additional 20 feet from the edge of Zone 1. Updated l l/1/2005 Page 11 of 13 3. If buffer mitigation is required, please discuss what type of mitigation is proposed (i.e., Donation of Property, Riparian Buffer Restoration / Enhancement, or Payment into the Riparian Buffer Restoration Fund). Please attach all appropriate information as identified within 15A NCAC 213 .0242 or.. 0244, or .0260. XI. Stormwater (required by DWQ) Describe impervious acreage (existing and proposed) versus total acreage on the site. Discuss stormwater controls proposed in order to protect surface waters and wetlands downstream from the property. If percent impervious surface exceeds 20%, please provide calculations demonstrating total proposed impervious level. Prior to construction of the guyed tower, no impervious acreage existed within the subject property. Construction of the guyed tower requires three 5' X 10' cement anchors one 3'6" X 8'6" cement base for the generator, and one 15' X 15' cement base for the equipment shed. XII. Sewage Disposal (required by DWQ) Clearly detail the ultimate treatment methods and disposition (non-discharge or discharge) of wastewater generated from the proposed project, or available capacity of the subject facility. No wastewater is proposed to be generated from this guyed tower. XIII. Violations (required by DWQ) Is this site in violation of DWQ Wetland Rules (15A NCAC 2H .0500) or any Buffer Rules? Yes ® No ? Is this an after-the-fact permit application? Yes ® No ? XIV. Cumulative Impacts (required by DWQ) Will this project (based on past and reasonably anticipated future impacts) result in additional development, which could impact nearby downstream water quality? Yes ? No If yes, please submit a qualitative or quantitative cumulative impact analysis in accordance with the most recent North Carolina Division of Water Quality policy posted on our website at http://l12o.enr.state.nc.us/ncwetlands. If no, please provide a short narrative description: The addition of this cell tower is not expected to induce further development. XV. Other Circumstances (Optional): It is the applicant's responsibility to submit the application sufficiently in advance of desired construction dates to allow processing time for these permits. However, an applicant may choose to list constraints associated with construction or sequencing that may impose limits on Updated 11/1/2005 Page 12 of 13 work schedules (e.g., draw-down schedules for lakes, dates associated with Endangered and Threatened Species, accessibility problems, or other issues outside of the applicant's control). ? G6 'Appficanf/Agent's Signature Date (Age 's signature is valid only if an authorization letter from the applicant is provided.) Updated 11/1/2005 Page 13 of 13 AGENT AUTHORIZATION FORM Name: Atlantic Seawinds Communications, LLC Address: 620 Whiteville Rd. NW Phone: Project Name/Description: -Wet Ashe Swamp/ Guyed Tower in Brunswick County_ Date: 04/04/2006 The Department of the Army U.S. Army Corps of Engineers, Wilmington District Attention: _Mr. Thomas Farrell Field Office: -Wilmington Re: Wetland Related Consulting and Permitting To Whom It May Concern: I, the current property owner, hereby designate and authorize Kimley-Horn and Associates, Inc. to act in my/our behalf as my/our agent solely for the purpose of processing of Section 404 permits and Section 401 Water Quality Certifications applications and to furnish upon request supplemental information in support of applications, etc. from this day forward until successful completion of the permitting process or revocation by the owner. Authorized this the 4t' day of April 2006 Tony L. Hall - Wireless Engineer Print Property Owner's Name P eity er's Signattu'e 1-888-367-2862 70? COLUMBUS f% \ B UNSw1l11 ?, r rJ U 50 100 0 10 iVliles O V p `o dN eoen '? ? , a P\\Ia \'R' I -N ?I -6 It / O U 130 w- Ludlun•Rd.NW • z \ O O Qm O T? O ti \r-- O 0 0.5 1 \ \ 1 Miles Title Vicinity Map Project Atlantic Seawinds Communications, LLC - Wet Ashe Swamp Prepared r°r Brunswick County, North Carolina Atlantic Seawinds Communications, LLC Date Project Number Figure 4/7/06 012537013 1 T?\pn\012537013 - Wet Ashe Swamp\figures.doc Prepared by Tyler McBwen [Mri .mr""i? . l % Nw) Par, .10 T, t. 16- _. ?o COer?n QC-.) Cerra \ C Hjv.39 <- f ¦ __ r \ 1>. + Griffin / ? • '? - - -- - - - - /_ ? .?- ?? it - • - f Certi ? - ?? '4 lion Ck j57? 66 _ _ - _ -Its -------?--- - -- Legend _ ) ` • Tower Center -? + t ® Lease Area -..- Title 7.5 Minute Topographic Map (Freeland and Exum, NC) P d F Project [Atlantic Seawinds Communications, LLC - Wet Ashe Swamp repare or runswick County, North C arolina Atlantic Seawinds Communications, LLC Date Project Number Figure 4/7/06 012537013 2 T:\pn\012537013 - Wet Ashe Swamp\figures doc Prepared by Tyler McEwen [=n m . ?f sib UAW,. 4A k ? " d *i .t. %4 `N .f p yw gcw Title Soils Map Project Atlantic Seawind YCommunications, LLC - Wet Ashe Swamp For Prepared Brunswick County, North Carolina Atlantic Seawinds Communications, LLC Date Project Number Figure 4/7/06 012537013 3 T:\pn\012537013 - Wet Ashe Swamp\figures.doe Prepared by Tyler McEwen 40 3 ?y . t?k &'?'" r x I z ? y u t l< ¦ Title Wetland Impacts Map Project Atlantic SeawindyCommunications, LLC - Wet Ashe Swamp Prepared For Brunswick County, North Carolina Atlantic Seawinds Communications, LLC Date Project Number Figure 4/7/06 012537013 4 T\pn`.012537013 - Wet Ashe Swamp\6gures. doc Prepared by Tyler McEwen s®?\ APPROXIMATE SCALE 2000 0 2000 FEET ZONE NATIONAL FL400 INSURANCE PROGRAM \ FIRM Iii it ll' FLOOD INSURANCE RATE MAP Milliken \ III Swamp ZONE C \.. BRUNSWICK IIL COUNTY, NORTH CAROLINA IIIIIIIIIII? (UNINCORPORATED AREAS) PANEL 200 OF 395 i? Long Bays COMMUNITY-PANEL NUMBER 370295 0200 C C-1 EFFECTIVE DATE: MAY 15, 1986 Federal Emergency Management Agency I This is an official copy of a portion of the above referenced flood map. It np was extracted using F-MIT On-Line. This map does not reflect changes or amendments which may ha" been made subsequent to the date on the title block. For the latest product information about National Flood Insurance Program flood maps check the FEMA Flood Map Store at www. msc. fema. go, DATA FORM ROUTINE WETLAND DETERMINATION (1987 COE Wetlands Determination Manual) Project / Site: W E AS c: w /t m - )?? Date: 03 0 20 o C. Applicant/ Owner: ItrLAwrlc. S Est w i N rJs 6 nx rAtAN (cpmoAlt(.AC c JC County: R &JS (At Investigator: 6RA (LJM State: C Do normal circumstances exist on the site? Yes ? No Community ID: Fog Is the site significantly disturbed (Atypical situation)? Yes No ? Transect ID: W I - Is the area a potential problem area? Yes No ? Plot ID: W ETA p-lb (explain on reverse if needed) VEGETATION Dominant Plant Species Stratum Indicator Dominant Plant Species Stratum Indicator 1. }Gtr rabrum TEA 9. 2. IQUid6^6a.i !*A491"A' Tl5 T=AC+ - 10. r P6 C' 3. f i?us it ed" 11. _ 4. l.iAv?slrvw? s?nonrt 5 FA C' 12. 5. AK re .-?o??? V ?( 13. FA&N 14. 15. 8, 16. Percent of Dominant Species that are OBL, FACW, or FAC excluding FAC-). I D D Remarks: Wetland Vegetation Present Based Upon Greater than 50% of the Plant Species are/are not Classified as FAC-OBL in the National List of Plant Species that Occur in Wetlands. Sample plot was taken... HYDROLOGY _ Recorded Data (Describe In Remarks): Wetland Hydrology Indicators _ Stream, Lake, or Tide Gauge Aerial Photographs Primary Indicators: _ Other Inundated " Saturated in Upper 12 No Recorded Data Available _ Water Marks _ Drift Lines Field Observations: Sediment Deposits Drainage Patterns in Wetlands N Depth of Surface Water: A (in.) Secondary Indicators: Oxidized Roots Channels in Upper 12" Depth to Free Water in Pit: (in.) _ Water-Stained Leaves Local Soil Survey Data Depth to Saturated Soil: 1 (in.) FAC-Neutral Test T Other (Explain in Remarks) Remarks: SOILS Map Unit Name (Series and Phase): Ly N (_H Qy,? I:--l N6 S&N /A Aftrainage Class: S oMCw? aoai aLa,?,Q Taxonomy (Subgroup): A ERIC Pit LE ft Q k 1_T-S Confirm Mapped Type? Yes_ No Profile Description: Depth Matrix Colors Mottle Colors Mottle Texture, Concretions, (inches) Horizon (Munsell Moist) (Munsell Moist) Abundance/Contrast Structure, etc. x(12 ??1 I o S aA Hydric Soil Indicators: _ Histosol _Concretions _ Histic Epipedon _ High Organic Content in Surface Layer in Sandy Soils _Sulfidic Odor Organic Streaking in Sandy Soils _Aquic Moisture Regime Listed On Local Hydric Soils List Reducing Conditions V Listed on National Hydric Soils List Gleyed or Low-Chroma Colors -Other (Explain in Remarks) Remarks: WETLAND DETERMINATION Hydrophytic Vegetation Present? Yes ? No Is the Sampling Point Wetland Hydrology Present? Yes No Within a Wetland? Yes ? No Hydric Soils Present? Yes No Remarks: Location (describe) is/is not classified as a wetland based upon the criteria set forth in the 1987 Army Corps of Engineers Wetlands Delineation Manual. DATA FORM ROUTINE WETLAND DETERMINATION (1987 COE Wetlands Determination Manual) Project/Site: Wt wtt-?11P a3 Date: 06 a?ob Applicant/ owner: -c. G a,vs LLC- County: B?.uswicK Investigator: rh State: A/C Do normal circumstances exist on the site? Yes No Community ID: ! wt- Is the site significantly disturbed (Atypical situation)? Yes No Transect ID: N I - S Is the area a potential problem area? Yes No Plot ID: 6C1. (explain on reverse if needed) VEGETATION Dominant Plant Species Stratum Indicator Dominant Plant Species Stratum Indicator 1. O JA M fro 915", LA^ /v T- 9. 2. 10. 3. 11. 4. 12. 5. 13. 6. 14. 7. 15. 8. 16. Percent of Dominant Species that are OBL, FACW, or FAC excluding FAC-). O Remarks: Wetland Vegetation Present Based Upon Greater than 50% of the Plant Species are/are not Classified as FAC-OBL in the National List of Plant Species that Occur in Wetlands. Sample plot was taken... HYDROLOGY _ Recorded Data (Describe In Remarks): Wetland Hydrology Indicators Stream, Lake, or Tide Gauge _ Aerial Photographs Primary Indicators: _ Other Inundated _ _Saturated in Upper 12" No Recorded Data Available _ Water Marks _ Drift Lines Field Observations: _ Sediment Deposits N Drainage Patterns in Wetlands Depth of Surface Water: (in.) Secondary Indicators: Depth to Free Water in Pit: > Ig fin.) _ Oxidized Roots Channels in Upper 12" _ Water-Stained Leaves _ Local Soil Survey Data Depth to Saturated Soil: Ig (in.) _ FAC-Neutral Test Other (Explain in Remarks) Remarks: .4.t SOILS Map Unit Name (Series and Phase): LyAICI+B ZC 6 N.- 5AW 01 L AA Drainage Ciass:SDmt ww noer,(,. faUa? C Taxonomy (Subgroup): IC ? A1-6&&U U LFT Confirm Mapped Type? Yes_ No Profile Description: Depth Matrix Colors Mottle Colors Mottle Texture, Concretions, (inches) Horizon (Munsell Moist) (Munsell Moist) Abundance/Contrast Structure, etc. C' s 2 f ?j JO A_ rM Hydric Soil Indicators: _ Histosol _ Concretions _ Histic Epipedon -High Organic Content in Surface Layer in Sandy Soils _ Sulfidic Odor -Organic Streaking in Sandy Soils _ Aquic Moisture Regime -Listed On Local Hydric Soils List _ Reducing Conditions -Listed on National Hydric Soils List _ Gleyed or Low-Chroma Colors -Other (Explain in Remarks) Remarks: WETLAND DETERMINATION Hydrophytic Vegetation Present? Yes _ No ? Is the Sampling Point Wetland Hydrology Present? Yes _ No 7_ Within a Wetland? Yes_ No Hydric Soils Present? Yes No ./ Remarks: Location (describe) is/is not classified as a wetland based upon the criteria set forth in the 1987 Army Corps of Engineers Wetlands Delineation Manual. Edward L. Killough and Associates Surveying 5823 Highway 74 Indian Trail, North Carolina 28079 Tel. (704) 821-7111 Fax (704) 821-7152 E-mail: e-killo@yahoo.com CERTIFICATION OF LOCATION AND ELEVATION ATLANTIC SEAWINDS COMMUNICATIONS, LLC SITE NO. 478-091 SITE NAME: WET ASH SWAMP LOCATION: 5915 Mill Branch Road Ash, NC 28420 This is to certify that a survey of the above referenced site has been conducted and the following information has been obtained from that survey. EXISTING GUYED TOWER LOCATION HORIZONTAL LOCATION BASED ON NAD 83 LATITUDE & LONGITUDE (Horizontal Accuracy 15' +/-) LATITUDE 34 Degrees 02 Minutes 20.6 Seconds N LONGITUDE 78 Degrees 30 Minutes 10.5 Seconds W BASE GROUND ELEVATION (Vertical Accuracy 3'+/-) VERTICAL ELEVATION BASED ON NAVD 1988 IN FEET GROUND ELEVATION AT BASE OF TOWER: 37.1' ELEVATION AT TOP OF TOWER STRUCTURE: 337.1' ELEVATION AT TOP OF LIGHTNING ROD: 346.7' Date of Survey: February 22, 2006 1 hereby certify that the above information is correct and accurate to within the specifications as indicated: f CARQ Name: ? =0 :.0?ESS/p2.,9 ' dward L. Killoug , N.C.P.L.S. -1519 Qo :a SEAL • .,? L-15'19 cc 0 Date: March 1, 2006 Czx i !y ti0 1_04'70 11i00 ? ?,,? NOTES -THIS AS-BUILT SURVEY HAS BEEN PREPARED PARTIALLY FROM AN ACTUAL FIELD SURVEY AND PARTIALLY FROM MAPS AND DEEDS OF RECORD -PROPERTY SUBJECT TO ANY VALID & ENFORCEABLE EASEMENTS, RESTRICTIONS & RIGHT OF WAY OF RECORD. -ALL PROPERTY OWNERS ARE NOW OR FORMERLY. -ADJACENT OWNER INFORMATION TAKEN FROM BRUNSWICK COUNTY TAX RECORDS -AREA BY COMPUTER (COORDINATE METHOD) ,ALL DISTANCES SHOWN ARE GROUND DISTANCES UNLESS OTHERWISE NOTED -NORTH BASED UPON NC GRID (NAD 83) ELEVATIONS BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD 88) -THIS MAP OF LEASED PROPERTY DOES NOT CREATE A SUBDIVISION OF LAND -THIS MAP IS FOR AS-BUILT PURPOSES AND IS NOT A BOUNDARY SURVEY OF THE ENTIRE TRACT PIN i 1470DO67 CRAVEN D. MILLIGAN D.B. 120 PG. 355 1 I SEAL ?* L-1519 L: KS „ I HEREBY CERTIFY THAT THIS MAP WAS DRAWN FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION AND ACCURATELY DEPICTS THE LOCATIONS OF THIS SITE AS SURVEYED IN THE FIELD AND IS NOT INTENDED TO BE A BOUNDARY SURVEY OF THE OPERTY SHOWN. EDWARD l» KILLOU H P.O. BOX 369 5823 HWY 74 INDIAN TRAIL, NC 28079 N.C. PROFESSIONAL LAND SURVEYOR NO. L-1519 © Nx uAV?1 w Acma-m. >tc R Mfl ?thlme tM MF •.t-lela 6 PIN /14700067 CRAVEN D. MILIGAN D.& 120 PG. 355 ti ti p0? X1.;0 4-1; LEGEND PP ql? MIS • - CALCULATED POINT CGF - COMBINED GRID FACTOR CT - 18" REINFORCED CONCRETE PIPE ELEV - NAVD88 ELEVATION ET - ELECTRICAL TRANSFORMER GIN - GUY WIRE 18 - ICE BRIDGE IPS - IRON PIN SET JS - FIBER OPTIC JUNCTION BOX PP - POWER POLE RW - RIGHT OF WAY SF - SILT FENCE SO. FT. - SQUARE FEET TBM - TEMPORARY BENCHMARK TL - TREE LINE TP - TELEPHONE PEDESTAL VICINITY MAP NOT TO SCALE PADS ?c '? ? ? /\Pa. Roo / LEASE AREA rnsluaeEO LIMITS P ? 2.ta ACRES DO RRDYEO auTED VIER LRAT$ ' 20' NGRE /EGRESS 216 ACRES V 't! EASEMENT T / PIN 1 14700057 CRAVEN D. M0.LGAN L GRAVEL - / _ D.O. 120 PG 375 oravE sF n s CEN OF CR OF CREEK LEASE AREA CENTERLINE OF CREEK s 3 Y C B PIN 1,4700066 GRAPHIC SCALE \ PIN 114 1301 CLYDE DAMS O.B. 912 PG. 741 MARVIN M. HELTON AND JEAN C. HELTON O.S. 688 M 249 200 p 100 200 400 I I I I ( IN FEET ) 1 inch - 200 fL A WET ASH SWAMP 478-091 5915 MILL BRANCH ROAD BRUNSWICK COUNTY ASH. NO 28420 5 4 6MS10N6 SURVEY FOR: AS-BUILT SURVEY ATLANTIC SEAN DS EXISTING GUYED TOWER COMMUNICATIONS, LLC ,,, 3 2 SHEET 1 OF 2 1 LEGEND • - CALCULATED POINT CGF = COMBINED GRID FACTOR CT - 18" REINFORCED CONCRETE PIPE ELEV = NAVD88 ELEVATION ET = ELECTRICAL TRANSFORMER GW = GUY WIRE 18 = ICE BRIDGE IPS = IRON PIN SET JB FIBER OPTIC JUNCTION BOX PP POWER POLE RW = RIGHT OF WAY SF = SILT FENCE SQ. FT. - SQUARE FEET TBM = TEMPORARY BENCHMARK TL = TREE LINE TP = TELEPHONE PEDESTAL „ 1n CAP SEAL L-1519 I HEREBY CERTIFY THAT THIS MAP WAS DRAWN FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION AND ACCURATELY DEPICTS THE LOCATIONS OF THIS SITE AS SURVEYED IN THE FIELD AND IS NOT INTENDED TO BE A BOUNDARY SURVEY OF THE P OPERTY SHOWN. g z' EDWARD L KILLO GH P.O. BOX 369 5823 HWY 74 INDIAN TRAIL, NC 28079 N.C. PROFESSIONAL LAND SURVEYOR NO. L-1519 © not 11llLnrael Nm noowlls, n: .0r. oma 1°II s,w to ? - ai irY°x om an-nA 6 CENTER OF GUYED TOWER LOCATION LAT = 34-02-20.6 N LONG = 78-30-10.5 W GROUND ELEV = 37.1' NAND 88 CONCRETE PAD ELEV = 37.1' NAVD 88 TOP OF GUYED TOWER STRUCTURE ELEV = 337.1' NAVD 88 TOP OF LIGHTNING ROD ELEV = 346.7' NAVD 88 LEASE AREA ?X 2 -fix X _-2 ? CE MAD W OF COORD91 ORDI TONER AlES N 105784.87 x E 2170608.97' x x EOUIPMENT PLATFORM P PAD \ x x \ _ ?qb m:Pa NODS CONTROL MONUMENT "FIVER' MAO 83 COOROIMA N 95051.41 E 2158207.99' EEV - 98.8' WET ASH SWAMP ""SONS SURVEY FOR: 478-091 ATLANTIC SEAWINDS 5915 MILL BRANCH ROAD COMMUNICATIONS, LLC BRUNSNICK COUNTY 0 ASH. NC 28420 5 I 4 r 3 517E VICINITY MAP NOT TO SCALE i k k LEASE AREA GRAPHIC SCALE 20 0 10 20 40 7- 17 1 ( W FEET ) I inch = 20 tL w AS-BUILT SURVEY _ EXISTING GUYED TOWER t+uwo N? rc Lx ° SHEET 2 OF 2 DC IX IX 2 1 D C 8 A ATLANTIC TELEPHONE MEMBERSHIP CORPORATION ATLANTIC SEAWINDS cingular' COMMUNICATIONS, LLC WIRELESS,LLC TELEP I= SITE NO: 478=091 SITE NAME: WET ASH SWAMP ADDRESS: 5915 MILL BRANCH ROAD ASH, NC 28420 COUNTY: BRUNSWICK COUNTY PIN #: 14700067 ZONING: RU - PROPOSED OCCUPANCY: UNMANNED TELECOMMUNICATIONS FACILITY C nNTAC'TS PROPERTY OWNER CRAVEN DEMETTE MILLIGAN 5915 MILL BRANCH ROAD ASH, NC 28420 (910) 287-3986 ZONING DEPARTMENT BRUNSWICK COUNTY 75 COURTHOUSE DRIVE, NE BUILDING I PO BOX 249 BOLIVIA, NC 28422 (910) 253-2035 ATTN. HELEN BUNCH UTWTIES - ELECTRICAL SITE DATA BRUNSWICK ELECTRIC MEMBERSHIP CORP. P.O. BOX 826 SHALLOTTE, NC 28459 (800) 842-5871 TOWER OWNER - ATLANTIC TELEPHONE MEMBERSHIP CORPORATION UTILITIES - TELEPHONE TOWER ID - 478-091 ATLANTIC TELEPHONE MEMBERSHIP CORP. LATITUDE - 34' 2' 20 6' N 620 WHITEVILLE ROAD NW . SHALLOTTE, NC 28459 (888) 367-2862 LONGITUDE a 78' 30' 10.5' W ELECTRICAL APOGEE CONSULTING GROUP 7330 CHAPEL HILL ROAD - SUITE 202 RALEIGH. NC 27607 (919) 858-7420 ATTN: MIKE BEEZLEY CONSULTANT KIMLEY-HORN AND ASSOCIATES 3001 WESTON PARKWAY CARY, NC 27513 (919) 677-2138 ATTN: KEITH MARKLAND SITE ACQUISITION RAMSEY DEVELOPMENT SOLUTIONS 426 CARRINGTON DRIVE GARNER, NC 27529 (919) 612-0823 ATTN: JAY RAMSEY PROJECT MANAGE BYERS ENGINEERING COMPANY 10934 SEDGEMOOR LANE CHARLOTTE. NC 28277 (704) 621-7575 ATTN: DAVE PARKER EXISTING GROUND ELEV a 35' AMSL PROPOSED TOWER HEIGHT - 300' (AGL) PROPOSED TYPE OF TOWER - GUYED TOWER DRIVING DIRECTIONS FROM WILMINGTON, TAKE US-17 SOUTH TO SHALLOTTE. AT SHALLOTTE. TAKE HWY 130 (WHITEVILLE RD) EXIT FROM US-11 AND TAKE LEFT ONTO HWY 130 WEST. PROCEED ON HWY 130 WEST FOR APPROXIMATELY S MILES AND TURN RIGHT ONTO MILL BRANCH ROAD. 5915 MILL BRANCH ROAD IS FIRST ADDRESS ON RIGHT. PROPOSED TOWER SITE IS BEHIND EXISTING BUDDING AND IN FRONT OF TREE LINE. INDEX OF DRAWINGS T-1 PROJECT INFORMATION, VICINITY MAP, SHEET INDEX - SITE SURVEY SHEET 1 OF 2 - SITE SURVEY SHEET 2 OF 2 C-0 GENERAL NOTES & SPECIFICATIONS C-1 OVERALL SITE LAYOUT C-2 SITE PLAN C-3 GRADING PLAN 1 OF 3 C-4 GRADING PLAN 2 OF 3 C-5 GRADING PLAN 3 OF 3 C-6 - TOWER ELEVATION & ANTENNA INFORMATION.... D-1 ICE BRIDGE DETAILS D-2 SITE SIGNAGE DETAILS D-3 ACCESS ROAD AND FENCE DETAILS S-1 FOUNDATION PLAN S-2 FRAMING PLAN S-3 EQUIPMENT LAYOUT AND FOUNDATION DETAILS S-4 STRUCTURAL DETAILS 1 OF 3 S-5 STRUCTURAL DETAILS 2 OF 3 S-6 STRUCTURAL DETAILS 3 OF 3 E-1 SERVICE ROUTING PLAN E-2 GROUNDING PLAN & DETAILS E-3 SINGLE-LINE DIAGRAM, PANEL SCHEDULE E-4 ELECTRICAL DETAILS E-5 ELECTRICAL DETAILS E-6 ELECTRICAL DETAILS E-7 H-FRAME DETAILS E-8 ANCHOR GROUNDING DETAIL ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS ccwwwacnwa.uc cingular' WrttElE55 U.C RiWYW R K O14 A Kimley Horn and Associates, Inc. ,ar a,a Rs mR uea, ,vix wa..m? aro v,,,® pro n AY6 ?RQCQf - O, ?DJl01] Rune e?c wsa Rm..wln wo wx -n .bU -n KRIA 1-A I 478-091 ?x •Ra WET ASH SWAMP nz- S91S MILL BRANCH ROAD ASH, NC 28420 -- PROJECT INFORMATION, VICINITY MAP, SHEET INDEX T-1 NOTES -THIS SITE SURVEY HAS BEEN PREPARED PARTIALLY FROM AN ACTUAL FIELD SURVEY AND PARTIALLY FROM MAPS AND DEEDS OF RECORD -PROPERTY SUBJECT TO ANY VAUD do ENFORCEABLE EASEMENTS. RESTRICTIONS k RIGHT OF WAY OF RECORD. -ALL PROPERTY OWNERS ARE NOW OR FORMERLY. -ADJACENT OWNER INFORMATION TAKEN FROM BRUNSWICK COUNTY TAX RECORDS -AREA BY COMPUTER (COORDINATE METHOD) ALL DISTANCES SHOWN ARE GROUND DISTANCES UNLESS OTHERWISE NOTED -NORTH BASED UPON NC GRID (NAD 83) -ELEVATIONS BASED ON NORTH AMERICAN VERTICAL DATUM 1988 (NAVD 88) THIS MAP OF LEASED PROPERTY DOES NOT CREATE A SUBDIVISION OF LAND -THIS MAP IS FOR LEASE PURPOSES AND IS NOT A BOUNDARY SURVEY i OF THE ENTIRE TRACT SEAL q_?L-1519 L. K1 ......... ulHnu ? 1 HEREBY CERTIFY THAT THIS MAP WAS DRAWN FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION AND ACCURATELY DEPICTS THE LOCATIONS OF THIS SITE AS SURVEYED IN THE FIELD AND IS NOT INTENDED TO. BE A BOUNDARY SURVEY OF THE PROPERTY SHOWN. P.O. BOX 369 5823 HWY 74 INDIAN TRAIL. NC 28079 N.C. PROFESSIONAL LAND SURVEYOR NO. L-1519 roar vrac aox axM T6 lsin¢sp17HN0 ra'?AY .11 .-NN 6 LEGEND • - CALCULATED POINT CGF - COMBINED GRID FACTOR ELEV - NAVD88 ELEVATION ET - ELECTRICAL TRANSFORMER IPS - IRON PIN SET JB - FIBER OPTIC JUNCTION BOX PP - POWER POLE RW - RIGHT OF WAY SO. FT. = SQUARE FEET TBM - TEMPORARY BENCHMARK TP - TELEPHONE PEDESTAL onf LEASE AR l CENTER DF GUYED TOWER \ OF CREIX _I \ PIN IF 1470001301 \ CLYDE DAVIS ANS D.B. 912 P0. 741 5 1 4 T 3 PIN { 14700087 CRAVEN D. MI LGAN D.B. 120 PO. 375 j? ?TE j- RE) VICINITY MAP NOT TO SCALE 3 C B CENTERUNE MEEK GRAPHIC SCALE 011, { 14700088 MARVIN M. HELMN AND 200 4 100 200 400 1 I JEAN C. HELM 0.6L 888 PD. 249 ( IN FEET ) I inch = 200 fL A SITE SURVEY - a« RAM-AND GUYED TOWER aara x. xv 11m I'011 ?flWR S1M 1CM1N OE IX IX 0 Z ,? aaEr a IX IX SHEET 1 OF 2 2 1 sown WET ASH SWAMP RL" SURVEY OR: °A" 478-091 ATLANTIC SEANDS 5915 MILL BRANCH ROAD COMMUNICATIONS. LLC BRUNSWICK COUNTY o w/w/os Ia9 LEGEND • CALCULATED POINT CGF COMBINED GRID FACTOR ELEV m NAVD88 ELEVATION ET - ELECTRICAL TRANSFORMER IPS a IRON PIN SET JB FIBER OPTIC JUNCTION BOX PP a POWER POLE RW RIGHT OF WAY SQ. FT. a SQUARE FEET TBM - TEMPORARY BENCHMARK TP - TELEPHONE PEDESTAL SSSI??I?I s ,'4'SF AR?l f. SEAL L-1519 PIN # 14700087 CRETE ' CRAVEN ` 0. Mwcu1 PADS Da. 120 rn ass UU ? JUG ''r('?-j?+I??I7','?'?- Q? ? 20' 91GRESS/EORESS a UTILITY EASEMENT LLLIJJ VICINITY MAP ?•; NOT TO SCALE i TOM PIN r `U7 UEVV 3611' CENTER OF GUYED TOWER LOCATION L LAT 34-02-20.6 N st \ LONG . 78-30-10.5 W i'; aw 5 GROUND ELEVATION - 35.0' NAVD 88 CENTER IRON PIN ELEVATION - 35.11' NAVD 88 TIE OF GUYED TOYER I vs IRON PIN SET I MAO 83 COORDINATES I ' N 10558&63' \? 1 E 2150800.7x' \ ' . 1Y+E / MCI 1R? Y IN l?? WEI: LINE CRAVEN D. MILUOAN F DA. 120 M LEASE AREA yo !? 6.49 ACRES ' 2 O ` 282,743 SQ. FT. \ CENTERUNE CENTERUNC OF CREEK OF CREEK 1 HEREBY CERTIFY THAT THIS MAP WAS DRAWN FROM AN ACTUAL SURVEY MADE UNDER MY SUPERVISION AND ACCURATELY DEPICTS THE LOCATIONS OF THIS SITE AS SURVEYED IN THE FIELD AND IS NOT INTENDED TO BE A BOUNDARY SURVEY OF T"E PROPERTY SHOWN. P.O. BOX 369 5823 HWY 74 LINE TABLE LINE LENGTH BEARING Ll 300,00' N80'57'03'W L2 106.84' NI0.25'5YW L3 183.31' N84-54'23'W CURVE TABLE CURVE RADIUS LENGTH CHORD BE CL 40.00' 51.99' 48.41' N47 T PIN / 14700088 _- ?• ?? T MNtVINAN a HEUON \ \ / Y.AN C. MELTON e. es5 PG 24v P91 0 14 70001,30 \ 1E DAMS DAMS 1 GRAPHIC SCALE ? o.aL 9u PQ 741 \ 100 0 50 100 200 NCCS CONTROL MONUMENT 111 . MAD 83 COORDINA1E5 AILING N 95051.47 E 2135207.98' •40'07•W ELEV IN ( IN FEEL' ) 1 inch a 100 IL Nffhy-ft ??? WET ASH SWAMP SITE SURVEY 478-091 SURVEY FOR: ATLANTIC SEAWINDS RAWLAND GUYED TOWER rs rnu sn-me. r.E n,»a 5918 MILL BRANCH ROAD COMMUNICATIONS, LLC OE Ex EN% 03 ?ASHNC 254420 TM - _ _ o • as s 01/tS/O! rssurn tart PaT/a0NS,11UEnort ISSUED IM MVIEM o< a [?[ a n SHEET 2 OF 2 0 GENERAL SITE NOTES= 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE DRAWINGS AND SPECIFICATIONS. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE REQUIREMENTS OF THE STANDARD BUILDING CODE, SOUTHERN BUILDING CODE CONGRESS INTERNATIONAL, INC. (SBCCI) WITH LATEST REVISIONS, NATIONAL CODES ORDINANCE AND REGULATIONS APPLICABLE TO THIS PROJECT. 2. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING, BRACING AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE PROJECT MANAGER AND/OR ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH THE WORK. WHERE THERE IS A CONFLICT BETWEEN DRAWING AND ATLANTIC SEAWINDS COMMUNICATIONS, LLC SPECIFICATIONS, THE PROJECT MANAGER AND/OR ENGINEER SHOULD BE CONTACTED FOR CLARIFICATION. 4. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE, BUT WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE PROJECT MANAGER AND/OR ENGINEER SO THAT PROPER REVISION MAY BE MADE. MODIFICATION OF DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT WRITTEN APPROVAL OF THE PROJECT MANAGER AND/OR ENGINEER. 5. CONTRACTOR SHALL REVIEW AND BE FAMILIAR WITH SITE CONDITIONS. 6. TOWER, ICE BRIDGE AND CABINETS ARE SHOWN FOR REFERENCE ONLY. REFER TO SEPARATE PRE-ENGINEERED DRAWINGS FOR SPECIFIC INFORMATION. 7. ALL FINISH GRADES SHALL SLOPE MINIMUM 1/4 IN./FT. AWAY FROM EQUIPMENT IN ALL DIRECTIONS. CONTRACTOR SHALL SLOPE SWALES, AS REQUIRED, ALONG EXISTING TERRAIN TO DRAIN AWAY FROM COMPOUND AND ACCESS DRIVE. 8. THE LOCATION OF UNDERGROUND UTILITIES AS SHOWN ON THESE PLANS ARE BASED ON ABOVE GROUND STRUCTURES. THE CONTRACTOR IS HEREBY NOTIFIED THAT PRIOR TO COMMENCING CONSTRUCTION, HE IS RESPONSIBLE FOR CONTACTING THE UTILITY COMPANIES INVOLVED AND SHALL REQUEST A VERIFICATION AT THE CONSTRUCTION SITE OF THE LOCATIONS OF THE UNDERGROUND UTILITIES AND WHERE THEY MAY POSSIBLY CONFLICT WITH THE PLACEMENT OF IMPROVEMENTS AS SHOWN ON THESE PLANS. THE CONTRACTOR OR ANY SUBCONTRACTOR FOR THIS CONTRACT WILL BE REQUIRED TO NOTIFY UTILITY PROTECTION SERVICES AT (800) 632-4949 AT LEAST 48 HOURS IN ADVANCE OF PERFORMING THE WORK. ANY UTILITIES DAMAGED BY CONSTRUCTION ACTIVITIES SHALL BE REPAIRED BY THE CONTRACTOR, AT NO EXPENSE TO THE OWNER. 9. ALL CONTRACTORS TO USE THESE PLANS IN CONJUNCTION WITH ANY AND ALL SPECIFICATIONS PROVIDED BY THE PROJECT MANAGER. 10. ALL PERMITS AND FEES ARE THE RESPONSIBILITY OF THE CONTRACTOR. ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS ?MU.G„XM cingular'' ,IBYA M K OI,Z Y, IGmley-Horn and Associates, Inc. IOf! ORL R n01! IIOII?q wyAgA,,+m?, IAI wra ?nw2ar - o,aes?o+a •nro nm..wn F MR ... .RD am®a KRM me 478-091 I- 777= WET ASH SWAMP S91S MILL BRANCH ROAD ASH, NC 28420 GENERAL NOTES & SPECIFICATIONS C-0 11. DESIGN OF PROPOSED TOWER AND FOUNDATIONS PERFORMED BY OTHERS. INFORMATION PROVIDED ON THESE PLANS ARE FOR REFERENCE PURPOSES ONLY. NOTIFY ENGINEER OR PROJECT MANAGER OF ANY CONFLICTS OR DISCREPANCIES. 12. EXISTING DIRT/SAND ACCESS DRIVE IS AN ALL WEATHER, COMPACTED AREA WITH LITTLE OR NO VEGETATION. EXISTING ACCESS DRIVE IMPROVEMENTS ARE NOT REQUIRED FOR CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION, THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY CONSTRUCTION ACTIVITIES TO THE EXISTING DIRT/SAND ACCESS ROAD. ANY NEW FILL MATERIALS SHALL BE WELL COMPACTED. 13. EQUIPMENT AND MATERIAL AT THE SITE SHALL BE PROTECTED FROM DAMAGE DUE TO CONSTRUCTION ACTIVITIES. DAMAGE WILL BE REPAIRED AT THE CONTRACTORS EXPENSE. 14. SITE SHALL REMAIN SECURE AT ALL TIMES. 15. CONTRACTOR SHALL PROVIDE RED LINE MARKUP ON CONSTRUCTION- DRAWINGS SHOWING AS-BUILT CONDITION OF ALL PLAN DEVIATIONS AND SUBSTITUTIONS TO THE PROJECT MANAGER FOR TURNOVER TO OWNER. PIN /14700067 CRAVEN D. MILLIGAN D.B. 120 PG. 355 PROPOSED 300' i _ GUYED TOWER PROPOSED 20' ACCESS k UTILITY EASEMENT WITH 12' GRAVEL ROAD PROPOSED 300' FALL ZONE PROPERTY SIZE 1.120.870.13 S0. FT. (25.7 ACRES) EXISTING IMPERVIOUS SURFACE 31.023.0± SQ. FT. MOM PROPOSED IMPERVIOUS SURFACE 8.807.0± SQ. FT. (0.870 TOTAL (EXISTING k PROPOSED) 39.830.0± SQ. FT. (3.6X[) IMPERVIOUS SURFACES R CHANGE 0.87. -a. 300' IVY 300' O PROPOSED 60' x 60' / FENCED COMPOUND PROPOSED 240' GUYED WIRE AND ANCHOR / (TYP OF 3) PROPOSED TREE PROTECTION '-FENCE (SEE DETAIL ON SHEET C3) F ATLANTIC TELEPHONE MEMBERSHIP CORP. ? ATLANTIC SEAWINDS awrnmTwnaxa uc ' cingular' YJOXEIESS ILO s MO lm Kimley-Horn and Associates, Inc. aeor-m oMn,.mea, AK rTO.eAT - 01163)OfJ i PROPOSED LEASE AREA (282.7433 SQ. FT.) EXTENT OR LIMITS OF CLEARING GRAPHIC SCALE 200 0 100 200 400 ( IN FEET ) L inch a 200 ft J. tllo ?? N cz) Z Jw uoum o? 4rNe nm..nrn e0nee a ms ew acne .c? rt i nnMw«m°f m'Ow?ne n x w rem woes m ex a ea ea.e reN M? mne®eeemeeoi __ ...._ ..en M enee ie?ua.i. M..n cum n JSD ame®n XMIA IMF 478-091 WET ASH SWAMP S915 MILL BRANCH ROAD ASH, NC 28420 OVERALL SITE LAYOUT C-1 GENERAL SITE PLAN NOTES: 1. THE SITE SHALL BE GRADED TO CAUSE SURFACE WATER TO FLOW AWAY FROM THE EQUIPMENT AND TONER AREA. 2. THE SUBGRADE SHALL BE COMPACTED AND BROUGHT TO A SMOOTH UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 3. GRASSED AREAS DISTURBED BY THE WORK OF THIS CONTRACT SHALL BE GRADED TO UNIFORM SLOPE. FERTIUZED, SEEDED AND COVERED WITH STRAW. 4. CONTRACTOR SHALL MINIMIZE DISTURBANCE TO OVERALL PROPERTY WRING CONSTRUCTION. EROSION CONTROL MEASURES SHALL BE IN CONFORMANCE WITH THE NORTH CAROLINA GUIDELINES FOR SOC. EROSION AND SEDIMENT CONTROL 5. AUTHORIZATION FOR ACCESS TO AND WORK WITHIN PUBLIC ROAD RO.W. SHALL BE OBTAINED BY THE CONTRACTOR. THE CONTRACTOR SHALL ADHERE TO ALL SPECIAL REQUIREMENTS SPECIFIED IN THE AUTHORIZATION. 6. ALL OTHER VEGETATIVE COVER DAMAGED OR REMOVED DURING CONSTRUCTION ACTIVITIES SHALL. BE REPLACED IN KIND BY THE CONTRACTOR (UNLESS OTHERWISE NOTED} 7. PARKING SPACES ARE NOT REQUIRED FOR THIS DEVELOPMENT, HOWEVER, A 12' x 20' PARKING AND VEHICLE TURNAROUND AREA HAS BEEN PROVIDED. 8. THIS SITE IS NOT MANNED. IT IS PROJECTED THAT ONCE CONSTRUCTED, A VEHICLE SHALL VISIT THE SITE APPROXIMATELY ONCE A MONTH. PROPOSED 60' It 60' CHAIN LINK FENCE (8' MIN. WITH 3 STRANDS OF BARBED WIRE) SEE DETAIL 1 3 ) D-2 -3 -3 %- X- x E VEL CR ? /1\ rb PROPOSED 300' x GUYED LOWER (SEE DETAIL ON SH EET 06) PROPOSED GUY ANCHOR ?k1 (TUTS) (SEE TOWER AND II FOUNDATION DRAWINGS BY OTHERS) F P ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS cwcwxaenxx.°.a.c cingular' WIR[3ES$ LLC Kmley-Horn and Assodates, Inc. ran ma ea ann uw.r. w aiw. mr.. Asc Plao.x!or - orzeasma 9'f ICE B ((SEE DETAIL / 1 t\I L-_J PROPOSED 12' GRAVEL ACCESS ROAD (SEE- FLOOD NOTE THE PROPOSED EQUIPMENT CABINETS AND GENERATOR WILL BE LOCATED IN A ZONE AE FLOOD PLAIN WITH A BFE OF 38' ACCORDING TO BRUNSWICK COUNTY FIRM MAP 3702950200 AND THE MOST RECENT FEMA MAPS AVAILABLE ON THE INTERNET. THE PROPOSED EQUIPMENT CABINETS AND GENERATOR WILL BE ELEVATED ON AN EQUIPMENT PLATFORM I' ABOVE THE EIFE. GRAPHIC SCALE m b zo 10 F:1' IN FM 1 inch - 20 ft PROPOSED 240' GUYED WIRE AND ANCHOR (TYP OF 3) FUTURE CO-LOCATOR (TYP OF 3) ?J PROPOSED EQUIPMENT CABINETS (SEE SHEET S3 FOR LAYOUT) I PROPOSED 15'-4' x 33' PLATFORM WITH EQUIPMENT ON 2'x2'xiB' CONCRETE SPREAD FOOTING (SEE DETAILS ON 'S' SHEETS) PROPOSED 3'-6' x 8'-6' GENERATOR (SEE SHEET S3 FOR LAYOUT) is, ,X X A PROPOSED 6' CHAIN LINK FENCE 1Wi}L 3 STRANDS OF BARBED WIRE (SEE PROPOSED 4 GANG DETAL/7\) METER RACK (SEE 'E' SHEETS) t PROPOSED 12' x 20' GRAVEI. PARKING AREA +?t PROPOSED 1Z' SWING GATE (SEE DETAIL anN lamo° A Mt 4d 1 wu n JSU - n KRM IR/ 1 478-091 WET ASH SWAMP 5915 MILL BRANCH ROAD ASH, NC 28420 SITE PLAN x.ar,anxa< C-2 EROSION CONTROL NOTES 1. EROSION CONTROLS SHALL BE QOM MAX. 5 INSTALLED PRIOR TO CONSTRUCTION AND SHALL BE ADEQUATE TO MAINTAIN SEDIMENT ON SIZE. 2. ALL EXCAVATED SOILS NOT NEEDED ON SITE FOR BACKFILL OPERATIONS SHALL BECOME PROPERTY OF THE CONTRACTOR AND SHALL BE TAKEN OFF SITE AND LEGALLY DISPOSED OF 3. . SOIL REMAINING ON SITE SHALL HAVE SILT FENCE TIGHTLY PLACED AROUND THE ENTIRE CIRCUMFERENCE OF THE PILE. ''•'{'' 4. PROVIDE EROSION CONTROLS AS NECESSARY TO PREVENT EXISTING SOILS FROM DRAINING OFF STE OR INTO EXISTING DRAINAGE STRUCTURES 5. ERECTION OF EROSION CONTROLS SHALL BE IN ACCORDANCE WITH STATE AND LOCAL EROSION CONTROL REGULATIONS NFATI*WROOF SIR! (AS SHDWN ABOVE} SEE NOTES BELOW FOR CONSTRUCTION AMD SPACNO DATA SECTION STEEL POSTS MAX. B' O.D. WIRE FENCE (1100 WIRE") ILTER FABRIC 30TTOM OF WIRE FENCE AND FILTER FABRIC BURIED B- IN EXCAVATED TRENCH STEEL POST DRIVEN 18' INTO GROUND SEDIMENT FENCE (SILT FENCE) NOT TO SCALE POST MAY BE EITHER 4' DIAMETER PINE. ?Y DIMIETR OAK. OR I -- lb/LF STEEL Tm Protection AM DO NOT ENTER s' NOTES MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. ADDITIONAL SIGNS MAY BE REWIRED BASED ON ACTUAL FIELD CONDITIONS. TREE PROTECTION FENCE NOT TO SCALE 5512! LEGEND EXISTING CONTOURS - -- - - PROPOSED CONTOURS SILT FENCE ev AM nor TPF w-- PROPOSED SPOT ELEVATION X842 tA A TLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWI ' cingular- WIRELESSLLC HViaW ? N eM w IGmley-Horn and Associates, Inc. w?e.?.am e+l?a.u an. pp mo pea armor r.. •rc rwoJCar - o,xeno,a GRAPHIC SCALE 20 0 t0 20 e0 77 1 SSS y?5 x? (W FEET ) x-x-x X- I inch - 20 fL >< r x ? I I L -J L SBd L J x 35.$ ?wI -_ x -x 7"', x j 'jo i wart es e?ee e> ML x, arwa s eeneeno w a e[ m Aaru,Y P M a•eR. . s r,1ca11t® ,w e: er x asa rAm.n,rea rewwa ""ro °mc?a s+e esoa _. emw ea JSD eose n KRM 478-091 I-- I WET ASH SWAMP ne- 5915 MILL BRANCH ROAD ASH, INC 28420 I- m GRADING PLAN 1 OF 3 o-3 LEGEND EXISTING CONTOURS — — — — PROPOSED CONTOURS SILT FENCE TPF +r w PROPOSED SPOT ELEVATION X842 GRAPHIC SCALE 20 0 10 20 w (INP') 1 inch — 20 iL ATLANTIC TELEPHONE MEMBERSHIP CORP. f ATLANTIC SEAWINDS cawr+anus uc cingulE p xwaw IClmiey-Horn and Associates, Inc. .or x xna w,mi r x o,w, sur b Jw Ym®M K0// 478-091 WET ASH SWAMP aw wows. 5915 MILL BRANCH ROAD ASH, NC 29420 GRADING PLAN 2OF3 C-4 NOTE CONTRACTOR TO OBTAIN ANY \ NECESSARY DRIVEWAY PERMITS FROM NCOOT AND FOR BRUNSWICK COUNTY. \ PROPOSED 20' 15- RCP (OR ..,? 31 g \,----APPROVED EQUIVALENT) \ _ .... J? \ \ \ \ \ ........«.?.r.+rr+.?....r,,........w?+.rr.w.rr «.+.,-.?.....r.r.....,..a rrr4...r.r,...,.,wr......r.+ EXISTING CONTOURS - - - - PROPOSED CONTOURS SILT FENCE .+ .« TPF - +?- PROPOSED SPOT ELEVATION X842 GRAPHIC SCALE 20 0 10 20 w ( IN FEET ) 1 inch - 20 & F ATLANTIC TELEPHONE MEMBERSHIP CORP. ° nB ATLANTIC SEAWINDS coW.vxrwnaNauG 0 a r- ' cingul l s • A - ?s? 19mley-Horn and Associates, Inc. wsc nnnaccr - 0+aesm+a 1l•5 wu at/u nmrxxn,a. wrt mwnis ro s K ni riov+n s°x a.wa rt s nm® au,a „e n K we, w m nmea K?lW WrtMmp s'?iwoN° e ?Kw10 MO?VK..K y w.wro ?W aaam ro Kml 478-091 30 5 -- I WET ASH SWAMP -- 5915 HILL BRANCH ROAD ASH, NC 28420 ror ro. GRADING PLAN 3OF3 C-5 TWELVE (12) PROPOSE D y,? b ANTENNAS ON TOWER. FOUR (4) RXl PER SECTOR. SEE TOWER DESIGN TX/ do STRUCTURAL ANALYSIS BY 1% XO PROPOSED ANTENNA OTHERS TO CONFIRM EXACT DECIBLE D898OG80T2E-M " MOUNT TYPE a 3 PROPOSED s! PROPOSED DECIBLE OBS80 GUYED TOWER FzD. I TYPICAL ANTENNA ORIENTATION PLAN 1 I SECTOR AZIMUTH MAC' ANTENNA ANTENNA DOWN DOWN (XAAXIAL CABLE COAXIAL CABLE AZIMUTH HEIGHT TILT ILI (Sim (OTY) ALPHA 350' 358' 3W DECIBEL DB98OG90T2E-M 2' 0' 771- 4 x 340't• BETA 120' 128' 300' DB98CG90 -M72E Y o• 2X- 4X340'!• 240' 248' 300' DECIBEL 48 T 0' 2k- 4 X 340'3• GAMMA 0G OOTIE-M D89 GE&R -mQ= 1. ANTENNA CENTERLINE HEIGHT BASED ON TOP OF GROUND ELEVATION AT TOWER CENTERLNE 2. ALL ANTENNA BRACIMIS PER ANTENNA MANUFACTURER. OR EQUAL CONTRACTOR TO C0"NATE REQUIRED MECHANICAL DOWNILT TWTH APPROPIMTE CAFUUM S ALL ANTENNA INFORMATION TO BE CONFNMED VATH PROJECT MANAGER PRIOR TO INSTALLATION. 4. ANTENNA INFORMATION OBTAINED FROM PROJECT MANAGER DATED APRIL 2Q 2004 • INCLUDES SAFETY FACTOR OF 15 FEET AT BOTH ENDS IANTENNA & COAX SCHEDULE 15GL` 1 9 1 COLOR CODES FOR RF LINES AND ANTENNAS SECTOR 1 SECTOR 2 SECTOR 3 (STRIPES) (STRIPES) (STRIPES) 1 WHITE I 1 WHITE 1 YELLOW 1 WHITE I GREEN RE 1 RED 1 YELLOW 1 GREEN 1 RED 1 RED 1 YELLOW 1 YELLOW 1 GREEN I GREEN 1 RED 1 YELLOW 1 GREEN COAX COLOR CODES AI PHA SECTOR RX MAN - RED/WHITE (TO DUPLEXER) TX1 ONLY - RED/RFD (TO TX FILTER) TX2 ONLY - RED/RED/RED (DITTO) RX DIVERSITY - RED (TO DUPLEXM) BETA SECTOR RX MAIN - YMLOW/WHITE (TO DUPLEXER) TXI ONLY - YELLOW/YELLOW (TO TX FILTER) TX2 ONLY - YELLOW/YELLOW/YELLOW (DITTO) RX DIVERSITY - YELLOW (TO DUPLEXER) GAMMA SECTOR RX MAIN - GREEN/WHITE (TO DUPLEXER) TXI ONLY - GREEN/GREEN (TO TX FILTER) TX2 ONLY - GREEN/GREEN/GREEN (DITTO) RX DIVERSITY - GREEN (TO DUPLEXER) ANT 1 ANT 2 ANT 3 ANT 4 D 1 T M 1 X X A V 2 3 1 N M1 NAA " C IRTAT. ON " POLE) TOP OF PROPOSED GUYED TOWER ELEVATION ANTENNAS CONTRACTOR RESPONSIBLE FOR INSTALLATION m 1. ANTENNAS AND ALL ASSOCIATED BRACKET MOUNTS AND HARDWARE. 2. LNA/MHA'S AND ALL ASSOCIATED BRACKET MOUNTS AND HARDWARE 3. COAXIAL • JUMPERS FROM ANTENNAS TO LNA/lMHA'S. • COAXIAL CABLE FROM LNA/MHA'S TO 7/8' JUMPERS AT BTS CABINETS • ALL CLAMPS STRAPS. CONNECTORS AND MISCELIANCOUS HARDWARE • GROUND KITS. • CONNECTORS R WEATHER PROOFING. NOTE ALL ABOVE MATERIALS SUPPLIED BY OWNER AND INSTALLED BY CONTRACTOR. - 4. GROUNDING • GROUNDING FROM THE LNA/MHA'S TO THE GROUND BAR AND ALL CRIMPS LUGS AND MISCELLANEXOUS HARDWARE SUPPLIED BY AND INSTALLED BY CONTRACTOR. • COAXIAL GROUND KITS TO BE CONNECTED TO GROUND LEAD FROM LNA/MHA'S WITH C-CRIMP SUPPLIED AND INSTALLED BY CONTRACTOR NOffi 1. ANTENNA CENTERLINE HEIGHT IS IN REFERENCE TO TOP OF GROUND ELEVATION. 2. ALL ANTENNAS TO BE FURNISHED WITH APPROPRIATE DOWNTLT BRACKETS. TOWER CONTRACTOR TO COORDINATE REQUIRED MECHANICAL DOWNTILT FOR EACH ANTENNA WITH PROJECT MANNER. 3. ANTENNA MOUNTS TO BE PROVIDED AND INSTALLED BY CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE 4. ICE BRIDGE AND WAVECUIDE LADDER R APPLICABLE. TO BE PROVIDED AND INSTALLED BY CONTRACTOR. 5. LINES AND ANTENNAS TO BE PROVIDED BY PROJECT MANAGER AND INSTALLED BY CONTRACTOR. 8. DURING CONSTRUCTION. THE CONTRACTOR SHALL PROTECT EXISTING EQUIPMENT AND STRUCTURES ANY DAMAGE WILL BE REPAIRED AT THE CONTRACTORS EXPENSE. CONTRACTOR SHALL NOT LEAVE THE SITE UNSECURED AT ANY TIME. 7. CONTRACTOR TO REFER TO FINAL RF CONFIC. PRIOR TO CONSTRUCTION. & CONTRACTOR TO INSTALL COAX PER STRUCTURAL ANALYSIS BY US CELLULAR. CONTRACTOR CAN OBTAIN A COPY FROM THE PROJECT' MANAGER. - LL-C. EQUIPMENT AND EQUIPMENT ??'I 3 ELEVATION N.LS. PROPOSED ATLANTIC SEAVANDS GUYED TOWER ELEVATION NOT TO SCALE (EXISTING GROUND EQUIPMENT NOT SHOWN FOR OAR IM ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS caw.urac•vons.us cingular- wmlaES IL.C Kimley-Horn and Associates, Inc. b.4 FTr?u Pq m-m Au Aez moATCr - olsaasola MR AAyae MvrwX? R?6 MR O WRn JSD aiv®N KRN XR F 478-091 BASE ELEVATION WET ASH SWAMP 1R Imo 5915 HILL BRANCH ROAD ASH, NC 28420 -- TOWER ELEVATION b ANTENNA INFORMATION C-6 CONTRACTOR SH41 ROUTE COAX UP TONER PER TOWER DESIGN. CONTRACTOR TO OBTAIN VARIES SEE STE PLAN COPY OF TOWER DES WANALYMS FROM PROJECT MVoam 2- 5!-0- D.C. MAX AS IN. PPE MAX MA%. 3' SID. STL 38• WIDE GMP STRUT, JB• RIDE GPoP SIRUP 14 OAUCE, 2' DFFP TH T (CALV.) 1FITH CMS 14 GAUGE. Y DEEP. SET ON TOP OF ANGLE IRON 4'-0' D.C. MAX PROPOSED GUYED IOWNR 3' STD. STL PPE 1- ? (GALV.) wm wS 1 U-BOLT MOUNTED OIRU ANGLE IRON _ NEW 2' z 2• (W L AINfXE u-Bator to STEEL PIPES J=w - LOWER TOWER BUSS BAR UNSTRUT ATACHED WNH BONDED TO 3/8' THREAM ROD. GUYED TOWER WASHERS " NUTS tS? AUGM HORIZONTAL CENTERLINE ,qq 1}77 qq ? OF COAX MOHWT H HORMONDL E OF CONNECTORS CLEI CENEER ... b S uNisnT ATTAOHFD W/ TN ? . UN I MUTS I WASI/ERS __ ? ? CONCRETE EIMASLMEM -1Y --- MIN. SEE MOTE (ft ICE BRIDGE DETAIL • NTS ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS COMMUeGATmm TLC cingular' novo r x rna m [Qmley-Horn and Associates, Inc. aW eT2 Rt Ar. went lall?l taasv. ? M6 erA.1mE M err-sa Mk AC M0.16CT ? OtRDSMti Ar>,N nmenar arms eo tu< w ttaew s woes rr ¦ x ct ?snxe'ma ierin?mru rarr.'Irl? R? V?Ils errs wNe rwnx?nolismois xwa. -_ - __ rrWtn JID rmo w OLY ea/ 478-091 WET ASH SWAMP rrt,eow 5915 MILL BRANCH ROAD ASH, NC 28420 ICE BRIDGE DETAILS D-1 E NOTE /3 GENERAL ICE BRIDGE NOTES: 1. CONNECT FAGN SUPPORT LED TO GROUND RING. 2 SUPPORT CDAINL CABLE EVERY 4'-D- O.F W%WUM. 3. REFER TO ELECTRICAL DRAWNGS FOR GROUNDING DEEAM 4. QED OF GRIP STRUT TO BE COVERED TO PREVENT EXPOSURE OF SHOAP EDGES. 1B. FOR ICE BRIDGE LEND" GREATER TKAN W ONLY - CONTRACTOR SHELL ALSO GROUND OOAX TO ISOLATED GROUND BAR ON RF CHAMBER D7U5EYENT ? 1'-0- ?' .. NOTE: ALL MATERUL AND HARDWARE TO BE HOT DIPPED GALVANIZED 2 ICE BRIDGE SECTION NTS ATLANTIC TELEPHONE FCC TOWER REGISTRATION N0 MEMBERSHIP CORP. . SIGNAGE NOTE: 1234567 ATLANTIC SEAWINDS 1. SIGNS SHALL MEASURE 8"X 12", BE FABRICATED FROM CORROSION RESISTANT $ WNrrEBACKGROUND NYBLACKETTHW(L PRESSED METAL. AND PAINTED WITH LONG LASTING UV RESISTANT COATINGS. Q OUANTRY.DTYPK'AL) (ONETO BE MOUNTED ON COMPOUND ACCESS GATE SEE MORE B) SIGNS (EXCEPT WHERE NOTED OTHERWISE) SHALL BEMOUNTED TOTHETOWER, 2 e cingular' "RELESSUC . AND FENCE USING A MINIMUM OF 9 GAUGE ALUMINUM WIRE, HOG RINGS (AS GATE , CKETS WHERE NECESSARY BRACKETS - . UTILIZED IN FENCE INSTALLATIONS) OR BRA SHALL BE OF SIMILAR METAL AS THE STRUCTURE T AVOID GALVANIC CORROSION. SITE ID# L 3. ATLANTIC SEAWINDS COMMUNICATIONS, LLC. SITE # AND EMERGENCY CONTACT # SIGNS SHALL BE MOUNTED ON THE A•BOX DOOR ADJACENT TO THE COMPOUND Kimle Horn Y ENTRY WITH PERMANENT SET ADHESIVE TWO-SIDED TAPE SHALL BE UTILIZED AT and Associates, Inc. EACH CORNER ON THE BACKSIDE TO AID PLACEMENT UNTIL ADHESIVE SETS. ? DO NOT NB ao AN+w. aN . 4 78 1 27 4. ADDITIONAL E911 ADDRESS SIGNS ARE REQUIRED AT EACH ACCESS ROAD GATE LEADING TO THE COMPOUND AS WELL AS ON THE COMPOUND GATE ITSELF. . a .,,aBOT _ p1 e63TOli CLIMB OBTAINING SIGNAGE : 5. RECOMMENDED SOURCE FOR CLAIR SIGNS RF EXPOSURE SIGNS ST MNrTE BACKGROUND W/ BLACK LETTERING WHRE BACKGROUND W1 BLACK LETTERING AMMY 1 C . 3184 WADE HAMPTON BLVD. RICHARD TELL ASSOCIATES SC 29687 3433 RINGSTAR ROAD. STE 3 TAYLORS OUANrRr. RI (rO BE MOUNTED ON ABOX DOOR ADUCENTTOCOMPOUND WW- SEE NOTE 3) ) L : ( (TO BE MOUNTED AT EYE LEVEL ON TOWER NEAR SAFWCLA1B) . (864) 244-0040 NORTH LAS VEGAS, NV 89WO - .. (702) 6453338 E-911 STREET ANTENNAS - W19TE Mro" ADDRESS MAY BE ACTIVE A. AB.Bac aw..:a GOmwiwnwuc qmY. eiwAOr AA,-Ytdalwsaa ah ? M saw • w.xn9 Me B x s.a 1IRE BIEET! OLINDWI wICKlETT6sN6 YELLOWSACM LN40 W1 BLACK LETTERING W EET A O GUANTrm (1) O ®71 STR e"? RsmtiA,lla,t7 bc1 FA'9 a-wY sMrsedahey AYpwba OownwnW)afaw.ah)Im..vMKelaaaw7M FFpAmr,MM AMwI rt?„"altm par rw lw W x,ae, ea m mum 1n.muaw w -sue saw NoA xMUeuni,artaton rterawoaw _ OUANTTIY : (1 IYPOM) Ro BE MOUNTED ON COANPDIaNO ACCESS wtq GREEN A-ft= YELLOW BAi01r1lr nT1011awna,0AP0. (TO BE MOUNTED ON FENCE FOR ALL VMS WMEIIETIEREM NO MSI®BREETIBKR4 Aq?-'?~ aawtn JSD ??•?> acooa A KRM IN CASE OF mme.e-a-a?.?wBaxe-eaa'a+:a.e.iabs •te F 478-091 NO TRESPASSING 1 WHITE - Beyond this point Radio frequency fields at this ske ` EMERGENCY p,OMszW M..r may exceed FCC rules for human WET ASH SWAMP AUTHORIZED a..GaP.:•a.w__?. --. exposure. ? ,. For your all Posted Bi9M OM ?Y. ?Y -A-A CALL ENTRY ONLY tz..rw..e.. Aa.a,e.?,bmc>-e+®.we *"? 1np? rado 5915 MILL swula rtaaD ASR. NC zsazo >_"`?."_ W"wiy,??,wAq,ti(Lw..4?a",)m„IA",AA•w-. i RIlpI P p ram.-Ism-Y.wr.N.:.Ww.iYY.AM.,I.,"t?•. F.awfwM?l -paa?s?vi-"4 1-800-298-3551 ?rMA[ WMMYEUOWBACAMOUNOWFOACKtETTEwuo SITE SIGNAGE DETAILS OUANUTY: m WHRE BAaQROUND WI BUCK LETTERING WHRE BACKGROIRD Ye REDLETIBOYG MASTS BACKGROUND W! &ACKIETTEtNB (TO BE MOUNTED AT EYE LEVEL ON TOWEL NEAR SAFETY CUMq au^NTTY:(t) OUP MY: 19 CUANTTM(1) PERACCESSGATE 4 PO BE MOUNTED ONCOMPOUiDACCESS GATq rTO BEON MOUNTEDASOX DOOR ADJA.CENMOOLFWD ENTRY- SEE NOYE31 MM 71COEMOI MON EACH SDEOFCOMPOUORENCE) TYPICAL SIGNS AND SPECIFICATIONS KT t ? D-2 2P (UNLESS NOTED OTHERMSE) F5c-I C LOOK MN. - /37 STONE GEOTEXTILE MATERIAL MIRAn-500X' (OR EQUAL) (OVERLAPPED 38' MIN.) COMPACTED SUBGRADE (95x MAX DRY f OENSTY N ACCORDANCE MTH ASTM 0696) NOTE AGGREGATE 15 BASED ON STANDARDS ANSI/ASTM D448 r SITE AREA SURFACING NTS MN. 4 FASTENERS ANGLED BARBED UK 45' ON ALL SIDES (TYP.) 7?p?m TC b«m lr 3 3 2 h J- PROVIDE CORNER POST WITH MIDRAIL AND T-Wo STARDAM ROUND PIPE D=ACE RAIL WHERE FENCE CHANGES DIRECTION BY MORE THAN W 2 GRAVEL ACCESS ROAD DETAIL NTS 110' MAX 811 MAX 8--0' MAX .ATE IRAIEE 2-0 SCH. 40 lfi x 3i' .. _ . SEE . SEE SIGH SHEET D-2, GA7FS /_( T7719ON BARS _ IYP.) W TRUSS RODS OTC. FTC. r v (T?•) TOY x 36' (nP-) ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS GOWAAAG11IDf4. Uv lr-? cinguELESS MN. ' LL M mItl m E)QSTND GRADE 1 PER FT SLOPE 7/4 PER FT SLOPE 1/4' X'y. ?.?•T't??. ('SI Ta^ l?? '.i?Sti..' •.Y tlry.:?.?ti' f1Cf .. ai, a •. a5. f... __.'R.,..i -.T:11•TY:r\ `ia. _ 19mley-Hom Inc. and Associates COMPACTED SUBGADE (%x MAX DRY DENSITY IN ACCORDANCE YATN ASTM 0896) B' Mn. cRUSRER RUN CONiRAC10R 10 NSTALL SURGE BEOIERTRE FABRIC MIRAR , ?* e? sLL T>A aq sn.>m Tq sn?LLa STONE AS NECESSARY. -I= OR APPROVED EQUAL wtle ?noUCVr - vRaeasoRa TOPE TOP OF CHAIN UKK FENCE (FABRIC) 7D BE 0`-O' ABOVE TOP OF FIN. STONE 3 TYPICAL FENCE SECTION NTS POST 2-.?.W1GE ( •) 'AM STEEL WIRE / 1-1('1 SID AROUND PIPE MY. MESH F CA. KUC (71P.) ??77 GAUGE BOTTOM 1E115pN MRE -FINISH GRADE TO BE FLU97 FINISHED GRADE SUPPLY rsx snsau xa a TILL ? tl CVA}Aw Ytl • M 7N p6??A'IiR ? 9?OIIIDAm Ytl O lle wLLIY /AA tlMMRI[?tlLLw1 ®ILL eK _.-_ ss?sll stl JED atln®w KRM >R 1 478-091 tlu rtl WET ASH SWAMP vw - 771 5915 LULL BRANCH ROAD ASH, NC 28420 ACCESS ROAD AND FENCE DETAILS D-3 PLATFORM FOUNDATION NOTES 2'X18 SPREAD c 1. GENERAL 1.1 FOUNDATIONS ARE DESIGNED BASED ON A PRESUMPTIVE ALLOWABLE SOIL BEARING CAPACITY OF 2.000 PSF. CONTRACTOR SHALL VERIFY SOL BEARING CAPACITY AND CONDITIONS PRIOR TO CCNSTRUcnoK 1.2 THE CONTRACTOR SHALL USE CAUTION WHEN EXCAVATING MORE THAN Y BELOW GRADE DUE TO THE POTENTIAL HIGH GROUND WATER CONDITIONS F ORGANIC OR SOFT SOBS ARE FOND THE FOOTING EXCAVATIONS SHALL BE UNDERCUT TO FIRMER BEARING MATERIALS AND BACKFILLED WITH UNIFORMLY GRADED WASHED '57 OR /57 STONE COMPACTED WITH A VIBRATORY PLATE TAMP. 1.3 CONTRACTOR SHALL BE RE" BIE FOR LOCATING, PROTECTING AND RELOCATING AS REOUIRED ALL SERVICE AND UTILITY LINES IN VICINITY OF THE WORK SRE ALL EXCAVATIONS NEAR THESE LINES TO BE CARRIED OUT WITH EXTREME CAUTION. 1.4 CONTRACTOR 70 Q/T/F1LL CONSTRUC1fOH AREA TO PROVIDE AN AREA AS LEVEL AS POSSIBLE FbORR . STRUCTURAL PLATFORM. ALL FILL AREAS ARE 70 BE FUZED WITH SUITABLE MAWdALS FILL MATERIALS ARE TO BE PLACED. COMPACTED. AND TESTED IN MAXIMUM LAYERS OF W. ALL TESTS MUST MEET THE MINIMUM SPECIFIED SO. BEARING CAPACITY. COMPACTION TESTING IS BY THE GEOTECHNICAL TESTING COMPANY DESIGNATED FOR THE PROJECT. SCHEIXANC AND COORDINATION B THE RESPONS381UTY OF THE GENERAL CONTRACTOR REPORTS OF ALL TESTING ARE TO BE PROMPTLY DELIVERED OR FAXED TO THE ATLANTIC SEAVANDS COMMUNICATIONS, IJP- AND ATLANTIC TELEPHONE MEMBERSHIP CORP., U.C. PROJECT MANAGER. 1.5 TOP OF FOUNDATION SHALL BE 3" ABOVE FINAL GRADE 2. MATERIALS 2.1 CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AT 28 DAYS AND SHALL BE INSTALLED N ACCORDANCE OATH THE LATEST REVISION TO AO-318 BUILDING CODE REQUIREMENTS FOR RENFORCfD CONCRETE. 2.2 CONCRETE SMALL HAVE A MAXIMUM SLUMP BETWEEN r AND C. 23 REWMCNO BARS SHALL CONFORM TO THE LATEST REVISION OF AS7M-ABI5 GRADE 60 SPECIFICATIONS AND BE DETAILED IN ACCORDANCE WITH THE LATEST REVISION TO AC-310. 2.4 TEST CYLINDERS SHALL BE MOLDED AND LABORATORY OARED IN ACCORDANCE WIN ASTM C31. THREE CYLINDERS SHALL BE TAKEN FOR EACH DAYS CONCRETE PLACEMENT. CYLINDERS SHALL BE TESTED IN ACCORDANCE VAIN THE LATEST REVISION TO ASIM C31L L5 CHAMFER ALL EXPOSED EXTERNAL CORNERS OF CONCRETE NTH 145' CHAMFER. VIER OTHERWISE NOTES 2.6 CONCRETE FORMHWORK B TO BE STRIPPED VAT IN 48 HOSTS VIBRATION OF THE CONCRETE MUST ASSURE THAT HONEYCOMBING WILL BE AT A MNMLAL MECHANICAL VIBRATION OF ALL CONCRETE IS REQUIRED UNLESS OTHERWISE DIRECTED BY ATLANTIC SEAWINDS COMMUNICATIONS. LUM AND ATLANTIC TELEPHONE MEMBERSHIP CORP., LLC PROJECT MANAGER. ABOVE GRADE CONCRETE IS TO SE RUBBED AND PATCHED TO ASSURE SMOOTH FINISH AT TIME OF FORMS REMOVAL CONTRACTOR SHALL PROVIDE A BROOM FINISH ON THE TOP SURFACE W THE EQUIPMENT FOUNDATION. L ELECTRICAL 3,1 CONTRACTOR SHALL REFER TO DRAWINGS OF OTHER TRADES AND VENDOR DRAWINGS FOR EMBEDDED MMS AND RECESSES NOT SHOWN ON THE STRUCTURAL DRAWINGS. CONTRACTOR SMALL VERIFY PLACEMENT OF EMPMENT AND LOCATION OF CONDUIT FOR MANUFACTURERS AND VENDORS SPECIFICATIONS. R SHALL BE THE RESPONSBFITY OF THE CONTRACTOR 70 PROVIDE ALL OPENINGS AND SLEEVES FOR PROPER GGIRIBU1UON FOR ALL UTEJIIM ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS QOMMJNKAIIONAMO ' cingular- WIRHESS LLC ?[ m,n Rn IGmley-Horn and Associates, Inc. ,p, RN%L WW a.. wan ?o?n w?aw aar bnl Tar-Tom R?9 ? Nr Arc PROJ[Gr - o'n - IBUz WR WYI NmaolNn RrRalr o a4 w c mnm?®re ? ?e nr< iwt.wn a TM< wla. rt e awAm '?Tw a tz a w?inw ?wo? WIN n JSD -n KRI R/ 478-091 R HWR WET ASH SWAMP I-- 5915 MILL BRANCH ROAD ASH, NC 28420 OQT TRI FOUNDATION PLAN 5-1 FOUNDATION PLAN SCALE: 1'S+5' 12' !,1 STRUCTURAL STEEL PLATFORM NOTES 1. STRUCTURAL STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-36 OR A992 OR 50. PIPING AND TUBING SHALL CONFORM TO ASTM A-500 CR B. ALL STD. PIPE SHALL BE SCHEDULE 40 UNLESS OTHERWISE NOTED. 2. ALL DETAILING, FABRICATION. AND ERECTION OF STRUCTURAL STEEL. UNLESS OTHERWISE NOTED. SHALL CONFORM TO THE LATEST REQUIREMENTS OF THE ALSO SPECIFICATIONS FOR BUILDINGS, LATEST EDITION. 3. PLATFORM WELDING SHALL BE DONE BY AN AWS CERTIFIED WELDER AND IN COMPLIANCE WITH AWS D1.1 ALL WELDS SIZES SHALL. BE THE MAXIMUM ALLOWED BY THE MATERIAL BEING WELDED WITH E70XX ELECTRODES. 4. UNLESS OTHERWISE NOTED, ALL FIELDS CONNECTIONS SHALL BE FULL DEPTH CONNECTIONS MADE WITH V DIAMETER HUGH STRENGTH BOLTS (ASTM A-325). 5. CONNECTIONS SHALL BE DESIGNED AS BEARING TYPE WITH THREADS :o EXCLUDED FROM THE SHEAR PLANE. ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS CO??AU,?CIITI K= cingular' WRiELFSS LLC 016 r Kimley-Horn and Associates, Inc. Iva was wn cw Iw0?1-m O+?u wo-m ra Arc ?nno.r<cr - waaa»,a 6. HOT DIP GALVANIZE ALL STRUCTURAL STEEL AND CRATING TOUCH UP ALL FIELD WELDS AND ABRADED AREAS WITH TWO COATS OF GALVANIZED PAINT. REPAIR OF ABRADED OR UNCOATED AREAS SHALL COMFORM TO THE LATEST VERSION OF ASTM A760-93A. 7. CONTRACTOR / STEEL FABRICATOR SHALL CONFORM TO THE MINIMUM EDGE DISTANCE REQUIREMENTS IN ACCORDANCE TO THE LATEST EDITION OF THE ALSO MANUAL OF STEEL CONSTRUCTION. FRAMING PLAN SCALE: 1'-5' & ALL STRUCTURAL STEEL SHALL BE FABRICATED TO FIT AT BOLTED CONNECTIONS WITHIN 1f INCH TOLERANCE. STRUCTURAL STEEL SHALL NOT BE FLAME CUT UNDER ANT CIRCUMSTANCES WITHOUT APPROVAL OF THE ENGINEER. 9. CONTRACTOR / STEEL FABRICATOR SHALL CAP OFF SEAL ALL PIPES AS REQUIRED TO PREVENT RAINWATER INTRUSION. 10. CONTRACTOR / STEEL FABRICATOR SHALL . SUBMIT SHOP DRAWINGS FOR in REVIEW PRIOR TO ANY STEEL. FABRICATION. AT THE CONTRACTOR'S OPTION, FIELD SPLICES MAY BE USED FOR ERECTION PURPOSES IF FIELD SPLICES ARE USED, THE SHOP DRAWINGS SHALL INCLUDE ALL DETAILS FOR THE PROPOSED FIELD SPLICES. 11. AT THE CONTRACTORS OPTION. SHOP WELDS MAY BE USED INSTEAD OF FIELD YIELDS 12 ATTACH GRATING TO FRAME PER THE MANUFACTURER'S RECOMMENDATION. b ' ifwac wx NN narrar armor ?a c our n SD -n KRM 1-0 1 478-091 WET ASH SWAMP n - 5915 MILL BRANCH ROAD ASH, NC 28420 rut m FRAMING PLAN most r.r, S-2 2'-B' 5' 15-4' 7 (j COLUMN 4-%"4 HILTI KWMK BOLT III EXPANSION ANCHORS WITH 43'4" HSS 4.5" x 0.237' MINIMUM EMBEDMENT PIPE COLUMN A e? ° n • ° . G .° 1' °• III 0 • '' Z K m? °x BTS 58000 U' q . d ..a .a G •$' F g g . o$w°0 F F°? RF mz STS x g 58000 3-/4 BARS TOP AND BOTTOM EACH WAY wow Z xg SECTION @ FOUNDATION ?? 1 $3 SCALE: 1" 1' Ir x >'(e" ORATING W1 BEARING / BARS O O O.C. GALVANIZED J - (GRATING NOT SHOWN TO SCALE) STAIRS ATTACH PER MANUFACTURERS SPECIFICATIONS 2' IYP. h a 4 -Fl!" HILTI KWIK BOLT RI EXPANSION ANCHORS WITH 4V.' INIMUM EMBEDMENT M GENERATOR g . HSS 4 .5" x 0.237" A CKK 3MIN. PIPE COLUMN (TTP) BASE PLATE DETAIL $3 scaLE:1"-r EQUIPMENT LAYOUT __.._-_-?_.?.._.....?--u?,., SCALE: 116 ?a •,r.?r.rr?r?r, ?"rrY??"wr ??M?Mw"?rr M ,Yrr?t MiY"rrrY?rl,tirr MxtiTSr "M ?V?ti4.YJ YIR,b WPx?,N?Y"F, ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS oaNnuxc?nwe, IJG cingularLLC N x[ Omz T Kimley-Horn and Associates, Inc. WE pq m-me Ni. w ModxOT - 01xAS 3 SEE FOUNDATION PLAN NOTE 1.2 ON SHEET ST FOR REQUIRED SUBGRADE PEPARATION :,.AN NxixeWY xtwaN xa xe ernes • enwaim NN N xc N1x rnmenr a• x< ona. x N nmKm n. N<n sa..a r,s w'u.,n ?a,?sNa xv..o wAM n JSD axa® w KRM Nc? 478-091 WET ASH SWAMP S91S MILL BRANOI ROAD ASH, NC 28420 EQUIPMENT LAYOUT AND FOUNDATION DETAILS 5-3 HSS PIPE C FRAME SECTION S4 SCALF:14s NOTE EQUIPMENT NOT SHOWN FOR CLARITY ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWIi6s oowaarwnonc. uc ' cingular- WIRELESS UC owns w x anw a, tGmley-Horn and Associates, Inc. ,mr was ww sow ?ir,?"^sm?ao-'am wx tie •no+cor - wau?wa W N nmrxrar auwn x wx se wwww n amewns r w x fai sm?: rw su rtw?wei wwin ?x .. xis a.'nrtwiso w n i ow?ma wwwrt x wmw nwrww s xwwn rww? n .6O oawm n RW 478-091 .x xna WET ASH SWAMP wn iaowos 5915 MILL BRANCH ROAD ASH, NC 28420 w -y- STRUCTURAL DETAILS 1 OF 3 SCALE: Pw1' 5-4 10 5 1B' 1Yi x 3Ce CRATING ??DIAGONAL BRACING CONNECTION HSS 4.5' z b.23r PIPE COLUMN o W THICK STIFFENER L W10c26 CIRDER-?/ BOLT W10x22 BEAM TO K. STIFFENER R. /- Q BEAM & COLUMN WIO?d2 BEAM --_q GIRDER & COUIMN GIRDER-EXTERIOR BEAM CONNECTION S5 SCALE: TST• PLAN VIEW f[ GIRDER & COLUMN V STIFFU NVO Ba W THICK (BI WI 0x20 2 GIRDER-CROSS BEAM CONNECTION SFj SCALE: 1" 1 PLAN VIEW BEAM ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS ca.MUr "Ta.%" cingular' WIRELESS LLC "o"o "vc ans w BEAM & COLUMN Krnley-Horn and Associates, Inc. qMp "eaev"r ic?aw ¦n &J -1 w."a ¦ mn"?ne w" x ? a ? o wn?iu:o "ems wv" ro JSD oca®ro KRM 478-091 WET ASH SWAMP m? 591S MILL BRANCH ROAD ASH, NC 28420 STRUCTURAL DETAILS 2OF•3 S-5 r 3 BEAM-GIRDER CONNECTION S5 SCALE: i`l' 7 TREADS O 11' - 6'-S' WELD HANDRAIL TO CHANNEL (TYP) 0 i TV I. WELD HANDRAIL TO CHANNEL (TYP.) o n I u I'1 `C10x15.3 O STEEL THREADS SHALL / 1 12" 316- OR NOSING (ORxAPPROVED EQUIVALENT) W10xu GIRDER BE TYPE B BY ICG RRA7RED IYP. 3x3x J'x O'-4' POST-MATCH LOCATION OF EACH CROSS-BEAM (WELD TO STIFFNER I PLATE) MAX SPACING - 5'-0' O.C. d I4-# STD. STEEL PIPE I RAIL-GRIND ALL WELDS (TYP.) (GALV.) VARIES W/ BEAM SIZE h TYPE (SEE FRAMING PUN) v d TOE PLATE Y.' x 4' CONT. WELD TO POSTS. I? i--GRATING • ? II SHOP WELD ej TYP 1/2- FACER . TYp GIRDER BEYOND BUILD-UP AREA AROUND STAIR FOOTING WITH COMPACTED GRAVEL OI \ `SPREAD F007ING 1• T„ 1'-6• DEEP w/ 5/8- ? MITI KTAK BOLT III /4 0 12- (MAX.) E.W. WALKWAY BEAM/GIRDER EXPANSION ANCHOR W THICK W/ 4' MIN. EMBEDMENT S"D FFNER PLATE HANDRAIL CONNECTION @ GIRDER STAIR DETAILS 2 SCALE: 1?1' S6 SB NOTTO SCALE ATLANTIC TELEPH MEMBERSHIP CORPONE . ATLANTIC SEAWINDS w?r+n.unm%uc ' cingular` MTMOAMOIQW lgmley-Horn and Associates, Inc. ==P= - Ase ?noxoT - o?xeaaoia iar.z - NN lame IIO. Ml? ?v° xc ..°?010? ss xrt xu Mn. ra sa I.Z v nu wn?'aort"'io? mrtrea w rt a romca iwrt is ?a.o.? a.x w.w u.r b .ISD ODJDA IOW >R ? 478-091 I-- WET ASH SWAMP m- 5915 MILL BRAN01 ROAD ASH, NC 28420 .arm STRUCTURAL DETAILS 3OF3 S-6 NOTE: CONTRACTOR TO PROVIDE PULL BOXES AS NEEDED TO ENSURE NO GREATER THAN 360 DEGREES OF BENDS IN CONDUIT BETWEEN PULL POINTS IN CONDUIT RUNS POWER CONDUIT STUBBED UP OUTSIDE FENCE CONTRACTOR TO COORDINATE WITH LOCAL POWER COMPANY FOR SERVICE TO THIS POINT. TELCO CONDUIT STUBBED OUTSIDE FENCE CONTRACT TO COORDINATE WITH LOC TELEPHONE COMPANY F SERVICE TO THIS POI 1. ALL ELECTRICAL WORK SHALL COMPLY WITH NEC, STATE, AND LOCAL CODES. 2. CONTRACTOR SHALL OBTAIN OWNER/TENANT SPECIFICATIONS AND RENEW FOR ADDITIONAL DETAILS MID REQUIREMENTS THAT MAY NOT BE SHOWN IN THESE DRAWINGS CONTRACTOR SHALL COMPLY WITH ANY ADDITIONAL OWNER/TENANT SPECIFICATIONS AND REQUIREMENTS. 3. CONTRACTOR SHALL APPLY FOR UTILITY SERVICES. B01H ELECTRIC AND TELEPHONE. FOR THE OWNER/TENANT. THIS APPUCATION SHALL BE MADE NO LATER THAN THE NEXT BUSINESS DAY FOLLOWING THE AWARD OF THE CONTRACT. CONTRACTOR SHALL COORDINATE WITH THE ELECTRIC UTILITY FOR THE EXACT TRANSFORMER LOCATION, METERING REQUIREMENTS, AND SERVICE ROUTING. CONTRACTOR SHALL COORDINATE WITH THE TELEPHONE UTILITY FOR THE EXACT TELEPHONE REQUIREMENTS AND SERVICE ROUTING. 4. PRIOR TO PURCHASING EQUIPMENT. THE CONTRACTOR SHALL CONTACT THE ELECTRIC 'UTILITY AND OBTAIN IN WRITING THE MAXIMUM AVAILABLE FAULT CURRENT AT THE UTILITY SERVICE POINT. THE CONTRACTOR SHALL ENSURE ALL ELECTRICAL EQUIPMENT, CIRCUIT BREAKERS. DISCONNECTS, FUSES, AND PANELBOARDS HAVE A FAULT CURRENT INTERRUPTING RATING GREATER THAN THE AVAILABLE FAULT CURRENT. IN NO CASE SHALL THE FAULT CURRENT INTERRUPTING RATING RE LESS THAN 10,000 AMPS & CONTRACTOR TO PROVIDE 2-200 LB TEST POLYETHYLENE PULL CORDS SECURELY FASTENED AT EACH END OF POWER AND TELCO CONDUIT. PROVIDE CAPS ON ENDS OF UNUSED CONDUIT. 6. PRIOR TO TRENCHING CONTRACTOR SHALL LOCATE ALL EXISTING UNDERGROUND UTILITIES CONTRACTOR SHALL REPAIR AT CONTRACTOR'S EXPENSE ANY DAMAGE TO EXISTING UTILITIES. 7. CONTRACTOR TO VERIFY EXACT ROUTING OF POWER AND TEL CO CONDUIT WITH LOCAL UTIU71ES AND OWNER/TENANT. ENSURE ALL CONDUIT STUD-UPS ACCOMMODATE EQUIPMENT REQUIREMENTS & UNDERGROUND CONDUITS SHALL BE SCHEDULE 80 PVC UNLESS NOTED OTHERWISE ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS coldw-NICATIMM itt Xcinaular' A POGEE I=.9'-- wav,vA nrgn.Ka var awlus..m saMgWaf .mvsascr?n ?_?_ W?AOO?daWS.hG. 9. CONDUIT RUNS SHALL HAVE A CONTINUOUS SLOPE DOWNWARD a? AND AWAY FROM THE EQUIPMENT TO ALLOW WATER TO FLOW ?n n?a AWAY FROM THE EQUIPMENT AND SHELTER. EXCAVATE TRENCHES ALONG STRAIGHT LINES PRIOR TO INSTALLING CONDUIT TO ACCOMMODATE ADJUSTING THE ELEVATION. AS NEEDED. od 10. CONDUIT ENTERING EQUIPMENT SHALL BE SEALED WITH A SEALANT THAT IS IDENTIFIED FOR USE WITH THE . CABLE/CCNDUCTOR INSULATION. SHIELDING, ETC. -... _ -X-%-X FURNISH AND THE CONTRACTOR SHALL SHALL OWNER It THE o ,n SM NA L S A L INSTALL ADDITIONAL SICNACE TO BE LOCATED AT THE COMPOUND FENCE CONTRACTOR SHALL COORDINATE WITH OWNER/TENANT cm n AS 1O PROPOSED H-FRAME U71UTY O (1) 2 1/Y POWER 8 g O (2) 3/4' CONDUITS FROM CONSTRUCTION MANAGER FOR PLACEMENT OF SIGNAGE s0 RACK (SEE SHEET E7) CONOUI FROM AUTOMATIC GENERATOR TO A-BOX LOW 12. PROVIDE CAP ON THE END OF ALL CONDUITS PROVIDE TRANSFER SWITCH TO PTS VOLTAGE ALARM TO TELCO SIDE MARKER (REPAR) AT END OF CONDUITS. MARKER SHALL BE 478-091 O NEW A-5 PPC CABINET CABINET. OF A-BOX 120V BATTERY ND OIL HEATER lO A MINIMUM OF 2 INCHES REMAINS ABOVE THAT DRIVEN SO D TH Oj GENERATOR WITH CHARGER A E WI SUB-GRADE. . EXPOSE PORTION OF REPAR TO BE COVERE I-- NEW 58000 EQUIPMENT NEW AUTOMATIC TRANSFER POWER SIDE OF A-BOX (SEE MANUFACTURER SPEC FOR ORANGE REPAR CAP. CABINET SWITCH CONDUCTOR SIZE). 13. CONTRACTOR SHALL SUPPLY AND INSTALL TERMINAL BLOCK WET ASH SWAMP O4 FUTURE N? SB000 EQUIPMENT ' 1' POWER CONDUIT FROM 10 AND WIRE FOR DOOR ALARMS ?aaum POWER CONDUIT © (1) 2 1/2 HAZARD LIGHTING PTS R ®(i) 3' lELCO CONDUIT FROM METER TO AUTOMATIC TRANSFER SWITCH CCONT OILER 5915 14LL BRANCH ROAD . 11 2-1/2" FLASH HEAD ASH, NC 28420 CONDUIT FROM HAZARD LIGHTING CONTROLLER TO HAZARD LIGHTS MOUNTED wim nn[ ON TOWER SERVICE ROUTING PLAN wm _ E1 SERVICE PLAN QCOMPRESSION LUG CONNECTOH ATLANTIC TELEPHONE (FURNISHED BY ®NEW A-5 BOX INSTALLED BY CONTRACTOR MEMBERSHIP CORP. . ATLANTIC SEAWINDS COMMUNICATION) ATLANTIC SEAWINDS X-X-X-X--x-X-%-%-X-7T %. OS NEW SB000 EQUIPMENT CABINET. INSTALLED Alm SUPPLIED BY ? G? uc ------------------------------- ATLANTIC SEAWN COMMUNICATION. 4O FUTURE 58000 EQUIPMENT CABINET. • r CI I I y U la r 1 / / I x RF1tSS LLC x @ )NEW ATLANTIC SEAWINDS COMMUNICATION ( p / / I I / x EQUIPMENT PLATFORM. ©NEW ATLANTIC SEAWINDS COMMUNICATION 5/8'XB' GROUND ROD. (TYP) " ' / \ P..- 'm I, ' i GROUND ROD XB O7 NEW ATLANTIC SEAWINDS COMMUNICATION 51B APOGEE l= 201 ? / I WITH INSPECTION SLEEVE TYP. FOR SINGLE POINT GROUND. awv, r?nm n .xa neoT ? - I 1 ( I 2 AWO BARE SOW TINNED COPPER WIRE ROUND RING W ?"°"m •o / . G ©NE " r.oec?mo.,sm?n x I 1 i / i BELOW GRADE. AT 30 ?? ?AUOdeles lm 1 ( \ 1 I COMMUNICATION ATLANTIC O GR O . . I 1 i SUPPORT LEG ON BOTH G R CONDUCTORS UNDI x I \ / x SIDES OF THE ICE BRIDGE USING EXOTHERMIC WELD. i,we =o.car - nzeroWs I I \\ D \ I I 7 10 SITE MASTER GROUND BUSS BAR FURNSHED WITH RF-BOX PROPOSE \ GUYED TOWER _N I it LOWER•TOWER BUSS BAR TO BE PROVIDED AND INSTALLED BY THE MOUNTED TO CONTRACTOR. TOLOWER WER (Z2)2RAWBUSS BAR SHALL C BARE TINNED BSOLID / - - - -- . COPPER GROUND WIRES ROOM BUSS BAR SHALL CAD - 14 ? ?• `` / \\ ?I x WELDED TO EOUIPMENT CARDIAC RING IN 2 PISCES. S REFERENCE 13 i ? 1 - -- DETAIL 2/E-5. ' f I ---- ' - ... ©BOND GROUND RING TO NEAREST FENCE POST (MIN. 2). 1 . B I x ' \ RF CHAMBER 13 CONNECT TO THE TOWER GROUND RING BY EXOTHERMIC WELD ?? I JJNNCCTION eo% WITH INSPECTION SEEVTS (TYP. T) --- --- A I I x 7g 10 14 TO TOWER SECTOR GROUND BAR (3 TYP.) GROUND TO EACH 16 OTHER AND THEN GROUND DIRECTLY TO TOWER WITH GREEN JACKET 4 AWG STRANDED COPPER WIRE. REFERENCE DETAIL .nr MA I I 2 OEN ..r.. e x ` 15 PTS GROUND BAR F31S ?: I ® 5 ( II i 16 TELCO GROUND BAR " 1 i lEGEBQ IIG M6 1 4 3 ? I ® SINGLE POINT GROUND ¦ CAD WELD CONNECTION --? 1 --- I x x e I -leJ ? INSPECTION PORT -1K--K- FENCE LINE O GROUND ROD - 51e X 8' LEASE LINE ---- - - - - - - - - -- - - - - - - - - - X-X-x-x-x-X X-x-X-X-X . COMPRESSION LUG CONNECTION - - - GROUND RING NOTE CONTRACTOR TO BO ND EACH JUNCTION BOX SPECIAL NOTE ww •n SAD TOGETHER WITH COMPRESSION LUGS, ALL JUNCTION BOXES TO A-5 PPC CABINET, AND ALL JUNCTION ANY EXCEPTIONS TO THIS BASIC GROUNDING ROUTING DESIGN OR DESIGN GUIDELINE a®? rn JMB BOXES TO RF CABINET. THE WHOLE SYSTEM WILL THEN BE GROUNDED TO PROPOSED ATLANTIC , , MODIFICATIONS, SHALL BE DOCUMENTED AND / SEAWINDS COMMUNICATION GROUND RING. DIMENSIONED BY WAY OF RED LINE DRAWINGS. N IS THE RESPONSIBILITY OF THE SELECTED 478-091 CONTRACTOR TO INSURE THE NEWLY INSTALLED GROUNDING SYSTEM MEETS THE STANDARD OF 5 S 3 8 / & / OHMS OR LESS. SEE GROUNDING NOTE WET ASH SWAMP SEE SITE PLAN FOR LOCATION OF CONCRETE PAD 1) THE GROUNDING FOR THE FUTURE PADS SHALL BE THE RESPONSIBILITY OF THE FUTURE CARRIER OR THEIR APPOINTED 4) R IS THE INTENT THAT AT NO TIME ARE THE GROUND LEADS TO BE INSTALLED BELOW THE SURFACE OF THOSE PADS OR SHELTERS U "x"°016` 771 OFSICNEE. RE AREAS DESIGNATED FOR FUT 5915 MILL BRANCH ROAD 2) ALL GROUNDING LEADS TO FLOW CLOCK WISE TO INSURE A SMOOTH PATH TO GROUND RING WITHOUT KINKS OR SHARP 5) THE GROUND WIRE LEADS FOR FENCE POST CORNERS AND RADIALS ARE TO BE INSTALLED AND CAD WELDED TO T CENTERS ASH, NC 28420 BENDS GROUND RODS ON MAX 20 FOO 3) CONTRACTOR SHAH UTILIZE THE 'FALL OF POTENTIAL-THREE POINT MEASUREMENT METHOD' UTILIZING THE AEMC-4500 MEASURING DEVICE OR APPROVED ATLANTIC SFAWINDS COMMUNICATION EOUAL ALL GROUND TESTING TO BE PERFORMED 6) THE CONTRACTOR SHALL DOCUMENT TEST RESULTS. REDLINE'THE DRAWINGS FOR THE LOCATION OF ALL UNDERGROUND GROUNDING COMPONENTS AND PHOTOGRAPH WITH A DIGITAL CAMERA THE ENTIRE NEWLY INSTALLED am mu t ND LAN BEFORE CONNECTING TO POWER UTILITY GROUND AND PRIOR TO ANY BACKFILL OF GROUNDING TRENCHES. ELECTRICAL GROUNDING SYSTEM SYSTEM PRIOR TO BACKTILL OF ANY OPEN TRENCHES. AND DETAILS CONTRACTOR SHALL PROVIDE A MINIMUM OF TWO (2) INSPECTION PORTS FOR TESTING GROUNDING RESISTANCE CONTRACTOR ' SEE GROUNDING PLAN FOR APPROX. LOCATIONS. MINIMUM NUMBER OF GROUND RODS INDICATED 7) GROUND WIRES TO TOWER GROUNDING SYSTEM SHALL ONLY BE CAD WELDED TO MANUFACTURERS GROUND LUG(S) . SHALL INSTALL THE CONTRACTOR SHALL INSTALL ADDITIONAL GROUNDING AS REQUIRED TO ACHIEVE 5 OHMS OR LESS GROUND RESISTANCE. ONLY. (NEVER CAD WELD DIRECTLY TO TOWER STRUCTURE) . ?? 1 E2 GROUNDING PLAN NOTES AND SPECIFICATIONS; 1. ALL ELECTRICAL WORK SHALL COMPLY WITH NEC. STATE, AND LOCAL CODES. 2. CONTRACTOR SHALL OBTAIN OWNER/TENANT EQUIPMENT DRAWINGS AND REVIEW FOR ADDITIONAL DETAILS AND REQUIREMENTS THAT MAY NOT BE SHOWN IN THESE DRAWINGS CONTRACTOR SHALT. COMPLY WITH ANY BE ADDRESSED IN THE EOUIPMENT DRAWINGS 3. THE GROUNDED SERVICE CONDUCTOR (NEUTRAL CONDUCTOR) SHALL BE GROUNDED AT THE SERVICE DISCONNECT ONLY. 4. ALL POWER CIRCUITS SHALL USE COPPER CONDUCTORS WITH THHN/THWN INSULATION. ALL TERMINATIONS SWILL BE RATED FOR AT LEAST 75 DEGREES C. 5. CONTRACTOR SHALL PROVIDE GROUND FAULT CIRCUIT INTERRUPTER (GFC0 TYPE RECEPTACLES FOR ALL UTILITY RECEPTACLES. 6. CONTRACTOR SHALT. ENSURE ALL NEUTRAL CONDUCTORS HAVE WHITE INSULATION AND EQUIPMENT GROUND CONDUCTORS HAVE GREEN INSULATION. COLOR TAPE IDENTIFICATION OF THESE CONDUCTORS IS NOT ALLOWED. 7. CONTRACTOR SHALL CONTACT THE LOCAL ELECTRICAL UTILITY AND OBTAIN, IN WRITING, THE MAXIMUM AVAILABLE FAULT CURRENT AT THE UTILITY SERVICE POINT. THE CONTRACTOR SHALL ENSURE ALL ELECTRICAL. EQUIPMENT, CIRCUIT BREAKERS, DISCONNECTS. FUSES, AND PANEL BOARDS HAVE A FAULT CURRENT INTERRUPTING RATING GREATER THAN THE AVAILABLE FAULT CURRENT. STEP DOWN TRANSFORMER BY UTILITY BY LOCAL U ILITY INCOMING HIGH VOLTAGE SERVICE T20/240V, 1 PHASE, BY LOCAL VfB.TTY 3- SECONDARY 2/0 AWG MBJ 20-KW GENERATOR WITH 2 PARALLEL. RUNS 2/0 AWG AUTOMATIC TRANSFER OF 3-500 KCMIL CEC SWITCH. ro ` AND PROPOSED METER V l T F] 190 SERVICE DISCONNECT. (SEE NOTE 7) v 4 'MDP' PANEL 200A 120/240VAC MCB ' M D P' PANEL 120/24W SINGLE PHASE 3 WIRE MIN. 10 WC, NEMA 3R 2P-125A BACKFED MAIN BREAKER NEUTRAL (100X) IN TOP GROUND BAR IN TOP LOAD IN KVA LOAD IN KVA A 0.00 B --- DESCRIPTION BACKFED MAIN EWER TRIP 2P-125 CKT 1 ZN4-+.rl CKT 17 TRIP -60 DESCRIPTION SURGE SUPPRESSOR A 0.00 B -- 0.00 - .00 -- 0.00 BACKFED MAIN BREAKER SPARE SPARE 2P-125 1P-15 - 2 18 19 0 2P-60 2P-50 P-50 5 RG SU RESSOR S-8000 BIN MAI N -8000 CABIN (MAIN BTS --- 4.20 0.00 - 4.20 0.00 PAR SPARE 1P-15 P-15 5 6 1-, 1 22 2P-b0 -50 S-8000 CAUINLISulmilyN B1S S-BWO CA81 IXTFNSI B 4. 0 --- - 0.00 SPARE P- 5 - 0 .00 .00 SPAR 10-15 B 24 1 F -T5 ARE 0.00 0.00 SPARE 1P-15 9 25 iP-15 SPARE 0.00 0.00 SPARE 1P-15 10 ?c 2 BLANK --- 0.00 --- SPAR 1P-1 1 2 - BLAN 0.00 SPAR P-15 1 28 -1 SPARE --- 0.00 0.00 SPAR 1P- 29 -15 SPARE - 0.00 PARE 30 - 0 TELCO F 0. 18 .00 SPARE 1P-15 15 31 -1P- 5 GFC RECEPTACLE 0.18 0.00 SPARE /P-15 16 2 1 -15 PTS OR -- 0.18 NOTE BACKFED CIRCUIT BREAKER SHALL BE SECURED IN PLACE BY ADDITIONAL A PER PHASE AMPS PER PHASE e 6 1'50 . 8.76 7,100 FASTENER IN ACCORDANCE WITH NEC ART. 408.16(F) JUIAL E D 1. LOLL CODE INSPECTOR MAY REQUIRE GROUNDING ELECTRODE CONDUCTOR CONNECTION WITHIN UTILITY METER (ACCESSIBLE FOR INSPECTION AND TESTING PURPOSES). 2. THE GROUNDING ELECTRODE CONDUCTOR (GEC) FROM THE SERVICE DISCONNECT NEUTRAL TO THE GROUNDING SYSTEM MUST BE CONTINUOUS WITHOUT SPLICES EXCEPT SERVICES IF MADE BY EXOTHERMIC WELD OR IRREVERSIBLE COMPRESSION-TYPE CONNECTORS PROTECTION (SEE NEC ART. 250.64 (C)) ENCLOSURE MAIN DISCONNECT A' A-5 PPC IY 'A ROX' INCOMING MEIEfi • CONDUCTOR NEUTRAL UCTOR UTILITY • 200A AWN BREAKER 2P I 3-3 AWC, L lOOA GEN 8 AWG EG, BREAKER 2P 10 KAIC 200A SPARE BREAKER 2P MOV SURGE PROTECTION 2-3/4- PVC CHARGER AND ALARM 2 AWC BARE TINNED C SINGLE-LINE DIAGRAM TRANSFORMER • O • ?- MASTER GROUND BAR 1 PROVIDED WITH _L SERVICES PROTECTION ENCLOSURE-AS GROUND ELECTRODE 2 AWC BARE SOLID -.,A- (BY LOCAL. UTILITY) - TINNED COPPER TO GROUND RING ISM-1 1 TYPICAL GROUNDING BLOCK DIAGRAM ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SLAWINDS COMM MCAT O M LLC 9' cingular'LLC RECESS A POGEEI'= ~ -- Oi G-PA ..w,M.C. VW, rmw. mm- +?rwr^? s A66 ?ROJ[OT - 013 0-37 moue 1R MR 2K 1 PPC CABINET PTS CABINET IMCO CABINET SEE Tam mwV ?n SAB PTS GROUND BAR BNB GROUND DETAIL E-5/2 BAR 1-0 478-091 • ATLANTIC SEAWINDS .G • COMMUNICATION 41 GROUND RING. 2 TO CABINET AWG BARE SOLID WET ASH SWAMP BONDING TINNED COPPER s¢ •oam 2 AWC BARE SOLED S91S MILL BRANCH ROAD TINNED COPPER ASH, NC 28420 SINGLE-LINE SINGLE POINT DIAGRAM, PANEL GROUND ROD WITH SCHEDULE INSPECTION WELL axm mwat rods, 2 E3 ATLANTIC TELEPHONE GATE FENCE MEMBERSHIP CORP. TOP OF GROUND ROD, 30' POST MIN. 8' BELOW FROSTUNE ATLANTIC SEAWINDS (WHICHE HEVER S DEEPER) HORIZONTAL 70 Ca9MMGnaNS, I1.C %NED GROUND ROD Y1?ry x ci larr / GRADE CADWELD TYPE GT TYPE SS TYPE OR u THERMOWEAD TYPE CONNECTfONS R LLC CR-2 1 GROUND / ^ RING /) C ROD SHALL NOT =-'°°'" POGEEI'n / BE ANGLED BE ANGLID MORE THAN a„,? uaw rA xx.gn.xc. zna - EXOTHERMIC WELD 30' FROM VERTICAL C, M4Nairxana CONNECTION TREATED ANGLE AWAY FROM ? r?.•? WITH TWO (2) COATS SHELTER OR PAD WHERE TYPE PT TYPE K 6 dA dri COLD GALVANIZED PAINT POSSIaIE DOUBLE GABLE OUND ROD GRAD sso n a A e w.aw DIAMETER COPPER TO GR .. xunxi amw•sa.xwr.rw CUD STEEL GROUND ROD ' LONG CADWELD TYPE NC THERMOWELD TYPE <Sol GATE JUMi'ER I 1 Are MO.COT - Otx0.! = 3 a CR-17 4/0 AWG . WELDING CABLE TYPE HA 1 O CADW LD CONNECTIONS ILYd ' 2 GATE GROUNDING DETAIL 3 D GROUND R BARBED WIRE CORNER FENCE S/S NUT POST COMPACTED 24' TRENCH OR AS READ - FRL BY POWEIVIELEPHONE CO. S/S BELLEVILLE WASHER FENCE UNEXCAVATED FABRIC ? HIGH TENSILE ELASTIC S/S FLIT WASHER Q WARNING TAPE GRAVEL FILL COMPACTED, (NO 2 AWE TNND SOLID BARE STONE/ ROCK R TOPPER WIR WIRE GD COMPACTED 1- 1/ 2' DVA) OR SIWb 7 70 EXFERIOR CROUNROUNO. RING g• 2 1/2' PVC --- 3' PVC TELEPHONE --- CONDUITS MAX FINISH xa wa I I POWER yQgFy Wr/ LOGY, CODES .111IT11 CONDUIT 1• AND UTILITIES ` I I I t * OR AS PER 2 AWC TINNED SOLID OCAL CODE BARE COPPER WIRE ' L REQUIREMENTS ."'- GROIR•1D ROD 5/8' x $' 19 . TYP. UTILITY CONDUIT TRENCH SECTION 4 LUG DETAIL 5 N.rs WALE FENCE GROUNDING DETAIL s wwx m vs amao m AID NON-THREADED • 6' DIAMETER x 3' PVC SLEEVE. V R NON-7HREADED - 6' DIAMETER x X PVC SLEEVE, COVER 1-f CO E FINISH FINISH " GRADE 478-091 EARTH GROUND LEAD TO ST GROUND LEAD TO 2 AWC SOLID, TINNED BARE COPPER TEST LOOP MASTER BUS QUARTTRWAVE STUB WEE ASH SWAMP I GROUND SRC Na 8 AGGREGAT DEEP. CR-e CRUSH RUN MIN ma EARTH SRC No. 8 AGGREGATES OR SRC CR-6 CRUSH RUN MW. 12' __T 5915 MILL BRANCH ROAD ASH, NC,28420 C1 8'- ?1NECT ION 'N°r 1Re CONNE CONNECTION ON ELECTRY DRIVEN COPPER CLAD DRIVEN COPPER CLAD ' ' ' DETAILS GROUND ROD 5/8'x6'-0' x8 -0 GROUND ROD 5/8 xm xux<x SINGLE POINT GROUND INSPECTION PORT DETAIL w;'a ' 7 INSPECTION PORT DETAIL N°:a ' 8 E4 TELCO CABINET DOOR SWITCH N/O R CON N/C G ATLANTIC SEAWINDS COMMUNICATION EXTERNAL BTS ALARM INTERFACE PHYSICAL WIRING STANDARD DETAIL POWER CABINET DOOR SWITCH N/0 COIN N/C MATERIAL NEEDED: -DUAL. POSITION, TEN PIN TERMINAL BLOCK. IDEAL PART NUMBER f 89-210 OR ; 89-410 -8 FEET OF 4 CONDUCTOR CABLE, CONDUCTORS 22 AWO, SOLID (STANDARD TELEPHONE WIRE IS OK) -ARROW STAPLE GUN, WITH T25 U SHAPED CABLE STAPLES -TWO f8 X 3/4' SELF TAPPING PHILLIPS HEAD SCREWS TO MOUNT TERMINAL BLACK -APPROPRIATE LASELJ14G DEVICE (SHARPIE PERMANENT MARKER. OR BROTHER P TOUCH LABEL MAKER IS ACCEPTABLE). -3M UY TYPE SCUTCHLOCK. : INSTALLATION 1. MOUNT THE TERMINAL BLOCK IN. THE TELCO SIDE OF THE ABOX. FACING THE ABOX TELCO COMPARTMENT, THE TERMINAL BLOCK SHALL BE MOUNTED WITH TWO NUMBER 8 X 3/4' SCREWS TO LEFT HAND SIDE OF CABINET PLYWOOD. THE TERMINAL BLOCK SHALL BE MOUNTED 6 INCHES FROM THE TOP OF THE CABINET, AND 6 INCHES FROM THE OUTSIDE DOOR EDGE OF THE PLYWOOD. 2. LABEL THE TERMINAL BLOCK ON THE OUTSIDE DOOR EDGE AS FOLLOWS: THE FFM AND SIXTH PINS FROM THE TOP OF THE TOP OF THE BLOCK SHALL BE LABELED AS FOLLOWS: A BOX DOOR'. ALL OTHER PINS TO BE LEFT WITHOUT LABELS. 3. WIRE THE DOOR SWITCHES IN SERIES USING THE 22 AWG CABLE USE ONLY TWO OF THE FOUR CONDUCTORS. TWO OF THE CONDUCTORS ARE SPARES 4. CUT A PIECE OF CABLE TO REACH FROM THE POWER SIDE OF THE A BOX TO THE DOOR SWITCH LOCATED ON THAT SIDE. CONNECT ONE WIRE TO COMMON 'C' AND THE OTHER WERE TO NORMALLY OPEN 'NO'. 5. FISH THIS WIRE THRU THE GROMMET HOLE IMMEDIATELY BEHIND THE SWITCH, AND INTO 1HE )4' HOLE IN THE REAR PANEL OF THE AC SIDE OF THE A BOX. DIRECTLY AND ABOUT 6' BEHIND THIS SWITCH. S. STRIP ONE WIRE OF THE TWO CONDUCTORS FROM THE POWER PANEL DOOR SWITCH TO TERMINAL '5; LEAVE THE OTHER ONE UNCONNECTED FOR NOW. DO NOT STRIP THIS WIRE 7. CUT A PIECE OF CABLE TO REACH FROM THE TELCO SIDE A BOX DOOR SWITCH LOCATED ON THE RIGHT SIDE CONNECT ONE WIRE TO COMMON 'C' AND THE OTHER WIRE TO NORMALLY OPEN 'NO. ' B. ROUTE THIS CABLE OVER TO THE TERMINAL BLOCK ON THE LEFT SIDE STRIP AND CONNECT ONE OF THE CONDUCTORS TO TERMINAL f S. 9. USING A 3M SCOTCHLOCK, INSERT THE TWO UNSHIPPED WIRES FROM EACH DOOR SWITCH INTO THE SCOTCHLDCK, AND USING PLIERS OR A SCOTCFAACK TOOL, COMPRESS THE UY CONNECTOR THAT WILL CONNECT THESE WIRES. 10. NEATLY AND IN AS STRAIGHT A LINE AS POSSIBLE, SECURE THE CABLE COMING FROM EACH SWITCH OVER TO THE TERMINAL BLOCK WITH T25 U TYPE CABLE STAPLES. STAPLE THE WIRE A MINIMUM OF EVERY 4 INCHES. 11. TEST THE ALARM SWITCHES USING AN OHMMETER AT THE TERMINAL BLOCK CONNECT ONE LEAD TO TB PIN 5 AND THE OTHER TO TB PIN 6. CLOSE THE POWER PANEL DOOR. PULL THE PLUNGER OUT ON THE TELCO DOOR SWITCH. A LOW RESISTANCE READING OF A FEW OHMS AT MOST SHOULD BE READ.ON THE METER. NOW. OPEN THE REAR DOOR. AND WITH THE OHMMETER STILL CONNECTED TO THE TERMINAL BLOCK. A HIGH RESISTANCE READING OF INFINITY OHMS SHOULD BE READ. WIRES FRt GROUND WIRES FROM WIRES FROM WIRES FROM - (NUMBER GROUND KITS GROUND KITS GROUND KITS COAXIAL ) (NUMBER OF (NUMBER OF (NUMBER OF - COAXIAL CABLES) J J COAXIAL GABLES) H COAXIAL CABLES) CONNECT GROUND WIRES TO 1/4'X4'XI5' CONNECT GROUND WIRES GROUND BAR WITH 2-HOLES LUGS. COPPER GROUND TO GROUND BAR WITH ALL SURFACES TO BE COATED WITH BAR (TYP) 2-HOLES LUGS. ALL KOPR-SHIELD. (TYP) 000000 0 0000 0 0 000000 0 SURFACES TO BE COATED WITH KDPR-SHIELD. 00 000000 0 000000 0 00000 0 00 000000 1 00000 0 0000 4-X4-XI CO 0 1 00000000 000000000 00 00000 PPER GROUND 00000 BAR CONNECT GROUND WARES TO 2 AWG TO GROUND BAR WITH 2-HOLES GROUND BAR LUGS. ALL SURFACES TO BE WITH CADWELO BUSS EWt SFIALL BE BONDED TO THE COATED WITH KOPR-SHIELD. TOWER USING A GREEN INSULATED 4 AWG STRANDED COPPER WIRE THE SECTOR BUSS BARS TO BE CAOWELDED 2 AWG BARE TINN SOLID COPPER WIRE BONDING STRAP SHALL BE CADWELDED TO EACH OTHER USING A GREEN TO THE BUSS BAR. INSULATED 4 AWG STRANDED COPPER CADWEIDED TO EQUIPMENT GROUND WIRE RING. TOP OR INTERMEDIATE GROUND BAR LOWER GROUND BAR CONNECTION DETAIL CONNECTION DETAIL CONNECT GROUND WIRES TO GROUND BAR WITH 2-HOLES LUGS. ALL SURFACES TO BE COATED WITH KOPR-SHIELD. WIRES FROM GROUND KITS (NUMBER OF BUSS BAR 2 AWG BARE CORRESPONDS 2-HOLES LUG SOLID TINNED WITH COAXIAL COPPER FROM CABLES) 4TH TERMINAL To CADWElD SINGLE POINT GROUND. GROUND WIRE CADWEDED TO 000 00000 BUSS BAR 000 0000 00000000 00000000 TO GROUNDING SYSTEM TELCO CABINETS GROUND BAR GROUND BAR END VIEW TELCO GROUND BAR DETAIL CONNECTION DETAIL ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SAWINDS CCMMBRIICA71(NS? 2 Xcing.ular' ?qR LLC POGEEI= ._ aow.rA AwiA.wc. nem PM?•*oa P?1 ?'® ?cros a rz wN m SAe Pm®m A18 478-091 -- WET ASH SWAMP 5915 MILL BRANCH ROAD ASH, NC 28420 I-- ELECTRICAL DETAILS MT GROUND BAR CONNECTION DETAIL °CAiF1: 2 E5 IDEAL IBT-300 SINGLE-POW GROUND TELCO CABINET'S GROUND BAR PIS PEDFSTAL TO SINGLE-POINT ///--- GROUND ROD AND INSPECTION SLEEVE. TO EXTERNAL GROUND BAR FACTORY FACTOR' AU-ED INSTALLED TELCO CABINET PEDESTAL GROUNDING THE AS PPC SINGLE-PONF /- GROUND Pfl TELCO CABINET RF CHAMBER PPCS JUNCTION Box GROUNDING BETWEEN THE CABINETS SECOND RF CHAMBER'S JUNCTION Box ¦1¦ JUNCTION Box PTS TELCO CABINET PTS'S GROUND BAR OPTIONAL PTS OPTIONAL PTS'S JUNCTION BOX OPTIONAL FOURTH JUNCTION BOX ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS COM"CAYIO N% MC Xcinkular' RE LLC A POGEEI'„ a,,rw1a1bi0 rower IA ro+p M.O r- ??I?.warnwem Mt,w.,m ?I-? MdAmrletn,Yn ?h?ne pMw,apMMa 11r[ MOJCQf - 01R8SIOti Mt ws olruul m SIB am®m JMB ims +? I 478-091 an M.a WET ASH SWAMP 5915 KILL BRANCH ROAD ASH, NC 28420 aar - ELECTRICAL DETAILS aar MiYlfl, E6 GENERAL NOTES: 1-ALL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE. STATE BUILDING CODES AND 6-SHOW LOCATION (INCLUDING DIMENSIONS) OF ALL CAPPED UNDERGROUND CONDUIT ON FINAL AS-BUILT THE LOCAL BUILDING CODES. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES AND EQUIPMENT DRAWINGS SUBMITTED TO OWNER. SHALL BE LABEL LISTED BY A NORTH CAROUNA APPROVED THIRD PARTY TESTING AGENCY. 7-COORDINATE EXALT lAGT10N OF UNDERGROUND FEEDERS AND dRWRR( WITH THE DINNER 2-REFER TO SITE LAYOUT PLAN FOR THE EXACT LOCATION OF H-FRAME B-CONTRACTOR SHALL COORDINATE EFFORTS WITH (LOCAL., ELEMI AL) AUTHORITY HAVING JURISDICTION (AHJ) AND 3-CONTRACTOR TO COORDINATE WITH LOCAL UTILITY COMPANY FOR METER, OTHER TRADES TO DETERMINE -FROST- LINE, AND TYPE(S) OF RACEWAYS REQUIRED FOR INSTALLATION. 4-CONTRACTOR TO PROVIDE AND INSTALL METER SOCKET. 9-BOND ALL ELECTRICAL EQUIPMENT TO RACK. 5-CONTRACTOR TO LOCATE METER RACK TO ENSURE WORKING SPACES REQUIRED BY THE NEC 10-DIMENSIONS SHOWN ARE APPROXIMATE AND MAY BE ALTERED IN THE FIELD AS APPROVED BY OWNER TO ART. 11026), STATE. OR LOCAL CODES ARE MAINTAINED BOTH ON THE FRONT SIDE AND THE BETTER SUIT ACTUAL CONDITIONS OR EQUIPMENT RECEIVED. M.K SIDE OF THE H-FRAME 8'-0" 4-CANG METER CENTER. S.E. RATED, U.L / LISTED, NEMA 3R ENCLOSURE. i- CAP END H O 3' SCR 40 GAILY. PIPE (TYPICAL) J 133 H Su O 175 FLASH HEAD L CAB E SEAL N N 133 _z u SILICO HAZARD LIGHTING L1 Z i s CONTROLLER NEMA 3R METER SOCKET-UL V w o ' ENCLOSURE LISTED, NEMA 3R gg PVC CONDUIT 1 ENCLOSURE ° ... FOR POWER FROM m a PTS N . { 0 2 GALV. UNISTRUT (TYPICAL) 5 E 21 h s 2/0 AWG HARE TINNED 4/0 AWG BARE TINNED I. PVC CONDUIT - SOLID COPPER GROUND SOLID CAPPER. CONNECT FOR TELCO FROM STRAP IN 3/4' PVC C TO NEAREST GROUND TELCO BO). TYPICAL PVC SLEEVE RING AND CADWELD TO POST (TYPICAL BOTH MIN. 24' INTO PIPES) GRDE GROUND S H EIAD CABLE 2 1/2' FI NOTE: O C PROTECTION CONDUIT (MIN. 18' BELOW j '• CONSTRUCT 50 GRADE)-STUB OUT TOWARD CONCRETE FOOTING EXTENDS 6" BELOW TOWER dl CAP S' FROM ACK L o AWG BARE LINE AND IN ?= MP R • • 4/ LANCE WITH ALL R ; . TINNED SIXID LOCAL AND STATE "•F" COPPER-BOND TO IXISTINC PROVIDE 2 PARALLEL if v RDA i GROUNDING RUNS OF 3-500 ICMIL. o RING 2 1/2' POWER EACH IN 3' SCHEDULE 80 PVC CONDUIT. TO \ j't 5/8" o It 8' CONDUIT TO ATS POWER CO. DEMARK. \ 1' (MIN) ` 30 DAY N COPPERCLAD STEEL CONCRETE MI . I DRIVEN GROUND STRENGTH OF 3000 PS ROD H-FRAME/METER RACK DETAILS (FRONT) I u 11 I H-FRAME/METER RACK DETAILS (REAR) ATLJWRC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS O0WMMMU7KK . UL' }'(cingular' RELES LLC A POGEEI=o,!`*- ° awp.M xr,g,,na f1MI smwaa r..?nw.m fm m ?_?_ fndA®odate[bc. Aac •nwfar - o,zs?so,a MMlaO frl M/ SAB am:MO Ma JMB 478-091 WET ASH SWAMP 59 KILL BRANCH ROAD ASH, NE 28420 -FRA E E A fMCT MN! 71 E7 ATLANTIC TELEPHONE MEMBERSHIP CORP. ATLANTIC SEAWINDS OMW. CATM% U.C Xcinular' REIESS LLC I#--r OAK STEEL BASE PlA A L P0GEEj==--- EXOTHERMIC WELD OR OmP.FA RYIIP?N.G DBDr e- V. 8/8' GROUND ROD BUPNDY KYOROUND pl?BweON ?mam APART AM SPACED A TO em M Of1EAACA y TO IX UAANFA SPECS)) IQmkµ#dR GROUND RBIG. IBC GUY WIRES 2 AWG BARE, TINNED SOW ROUTED AT 18' ANGLE N PVC BnerwAin u,nw. ?Inm.ww mnnww? TO TOWER BONDED TO TUNER GROUND IRNC USM ExOTHFRNIC WELD OR waR ??? - 0126?A?W BURNDY HYGRDVND SYSTEM. E7OlRUNG WELD OR BUNDY HICROUND TO FENCEPOST _ • TOWER . 2 AWG BARE. TINNED - GUY ANCHOR . GROUND RING GUY ANCHOR BASE DETAIL - TOP VIEW ROHM 310028 OR TOWER GUY WIRES (IYP) V. METAL CLAP CWT ERUIC WELD OR BUIUW WCOUND TO BASE (PER wrA? s?R A/W ?lurwn MANUFXWRER SPECS) . 2 AWO BARE. TINNED SOW' 2 AWG BARE TINNED., ROUTED AT . 48' ANGLE - GUY WIRE CAISSON ICM& OF THREE) 3/4r PVC SLEEVE THAT A UK OF Ur R?°01O (" • y NIO GROUND MR +r Of 4 GUY FENCE GROUND PoN0 IXOIHETRMIC 1BF1D OR N T O SYS EM 00M1N OF ?. BURIIDY NiGOU OMIT rA SIB BUM GRACE) o®® ac AID ROUT 340028 OR EOUIV MWTAL CLAMP 'R A 478-091 GUY ANCHOR BASE DETAIL - CROSS VIEW WET ASH SWAMP ra ysiea S91S MILL BRANCH ROAD ASH, NC 28420 rm >a? AN OR GROUNDING DETAIL ' BMQt RueOl GUY ANCHOR GROUNDING DETAILS 1Wevu EB