HomeMy WebLinkAbout10002_Rea_Building 6-VMI Letter 2012_12_21Certification of Vapor Mitigation Installation-Building 6 S&ME Project Number 1353-12-060 Silos, Charlotte, NC (Brownfields Site No. 11009-07-60) December 21, 2012 ______________________________________________________________________________________ 2 Vapor Mitigation System As approved in the Notification letter, the vapor mitigation system for Building 6 consisted of a spray-applied (Geo-Seal®) seamless membrane located beneath the building’s concrete slab and above the ground surface. The membrane consists of a bottom layer of Geo-Seal Base, then the spray-applied 60-mil (minimum thickness)Geo- Seal Core, and topped with a Geo-Seal Bond layer. The installation of the vapor mitigation system was generally installed per the design specified in the approved April 12, 2012 Notification letter and appended Technical Specifications for Vapor Barrier And Active Venting System, Silos Community (Technical Specifications) dated April 11, 2012 prepared by WSP-Sells. The only deviation from these specifications was the August 24, 2012, NCDENR-approved reduction in specified curing time of the spray-applied barrier (Geo-Seal Core) prior to collecting thickness measurements. This reduced curing time was based on information and specifications provided to the NCDENR by the manufacturer. Installation Dates Since Building 6 is a relatively small building, the installation of the vapor barrier was conducted in one day (December 11, 2012). S&ME was present and observed the installation and conducted the specified Quality Assurance/Quality Control (QA/QC) testing, as indicated on Table 1.Figure 4 indicates the approximate location of the various QA/QC thickness test locations. QA/QC Testing As specified in the approved Notification and Technical Specifications, S&ME conducted and/or observed the following QA/QC testing during membrane installation: Observed the ground surface for sharp objects prior to installing the barrier system; Observed and documented the installation of the Geo-Seal Base; Observed and documented the installation of the spray-applied Geo-Seal Core; Observed the sealing of penetrations (i.e., piping, wiring conduits, etc.); Collected two samples per approximate 1,000 square feet of the Geo-Seal Base and Geo-Seal Core after application and measured for thickness; Observed and documented the smoke testing of the membrane installation, prior to installation of the Geo-Seal Bond layer; and Observed the installation of the Geo-Seal Bond layer. FIGURES Scale: AS SHOWN Checked by:DAH Drawn by: RAS Date:11/1/12 USGS Topographic Map Silos Site 121 Lancaster Street Charlotte, North Carolina Figure 1S&ME Project No.: 1353-12-060 Site Area Charlotte West USGS Quadrangle dated 1993 and Charlotte East USGS Quadrangle dated 1967 and Photorevised in 1988. Scale: AS SHOWN Checked by: DAH Drawn by: RAS Date:11/1/12 2009 Aerial Photographic Map Silos Site 121 Lancaster Street Charlotte, North Carolina Figure 2S&ME Project No.: 1353-12-060 Map obtained from Mecklenburg County GIS Website Site Boundary Light Rail Corridor South Boulevard Youngblood Street Fairwood Avenue Griffith Street Lancaster Street Remount Road Approximate Scale: 1” = 186’ Silos SILOS (EXISTING)SILOS (EXISTING)SILOS (EXISTING) POOL AREA S I T E C O N C E P T U A L P L A N P R O P O S E D W O O D F I E L D S I L O S C O M M U N I T Y L A N C A S T E R S T R E E T & Y O U N G B L O O D S T R E E T C H A R L O T T E , N O R T H C A R O L I N A 3 1 3 5 4 -1 1 -1 9 8 1 " = 8 0 D D H 1 -1 1 -2 0 1 2 R A S FIGURE NO. S C A L E : P R O J E C T N O : D A T E : D R A W N B Y : C H E C K E D B Y : W W W .S M E I N C .C O M REFERENCE:BASE MAP PROVIDED BY DESIGN RESOURCE GROUP, PA. PLEASE NOTE THIS MAP IS FOR INFORMATIONAL PURPOSES ONLY. IT IS NOTMEANT FOR DESIGN, LEGAL, OR ANY OTHER USES. THERE ARE NO GUARANTEES ABOUT ITS ACCURACY. S&ME, INC. ASSUMES NORESPONSIBILITY FOR ANY DECISION MADE OR ANY ACTIONS TAKEN BY THE USER BASED UPON THIS INFORMATION. 0 80 160 Feet ± 12 34 56 SR2SR1 BUILDING 6 VAPOR BARRIERTHICKNESS SAMPLE LOCATIONSWOODFIELD SILOS COMMUNITYLANCASTER STREET & YOUNGBLOOD STREETCHARLOTTE, NORTH CAROLINA 4 1353-12-060 DDH WWW.SMEINC.COM SCALE: PROJECT NO: DATE: DRAWN BY: FIGURE NO. 12-19-12 1 " = 20 ' Q :\1 3 5 3 \2 0 1 2 \0 6 0 S i l o s \f i g 4 _V a p o r B a r r i e r S a m p l e s B l d g 6 .m x d ENGINEERING LICENSE NO: F-0176 ± REFERENCE:BASE FIGURES PROVIDED BY DESIGN RESOURCE GROUP, P.A. AND HOUSING STUDIO, P.A. PLEASE NOTETHIS MAP IS FOR INFORMATIONAL PURPOSES ONLY. IT IS NOT MEANT FOR DESIGN, LEGAL, OR ANY OTHERUSES. THERE ARE NO GUARANTEES ABOUT ITS ACCURACY. S&ME, INC. ASSUMES NO RESPONSIBILITY FORANY DECISION MADE OR ANY ACTIONS TAKEN BY THE USER BASED UPON THIS INFORMATION.Approximate Sample Locations 0 20 40 Feet TABLE Table 1 Summary of QA/QC Testing Results Sample ID Average Thickness1 Pass/ Fail2 1 0.1050 Pass 2 0.1170 Pass 3 0.0893 Pass 4 0.0955 Pass 5 0.1425 Pass 6 0.0936 Pass SR-1 0.1870 Pass SR-2 0.1456 Pass Notes: N/A = Not Applicable Yes 12/11/2012 Observe installation of Base, spray-applied Core layer, collect thickness samples, and observe smoke testing. Building 6 - Sprinkler Room Yes Yes Yes 1 Thickness measured with pre-calibrated calipers. 3 On August 17, 2012, NCDENR verbally approved a reduction in required curing time that reduced the time between application of spray-on barrier (Core layer) and thickness testing from >24 hrs to same day as application. An email written approval was sent from the NCDENR on August 24, 2012. Building No. 6 - Silos Community Poindexter Drive & Griffith Street Charlotte, Mecklenburg County, North Carolina S&ME Project No. 1353-12-060 Date Activity Location Thickness Measured? Thickness Measurements Smoke Testing Conducted? NCDENR Brownfields Project No. 11009-07-60 2 Thickness measurement required to be a minimum of 74 mil (0.074") for 14 mil thick Geo-Seal Base layer and 60 mil thick Geo-Seal Core layer in order to meet specification requirement of 60 mil for Geo-Seal Core layer. Yes Smoke Testing Pass? Comment Building 6 Yes SITE PHOTOGRAPHS Silos Community Site 121 Lancaster Street, Charlotte, NC Project #: 1353-12-060 Sheet 1 of 2 9751 Southern Pine Blvd. Charlotte, NC 28273 Photo 1 D a t e : 1 2 /1 1 /2 0 1 2 P h o t o g r a p h e r . J i m m y G o s n e l l Location Silos Community – Building No. 6 Remarks Preparation of subsurface for vapor barrier installation. Photo 2 D a t e : 1 2 /1 1 /2 0 1 2 P h o t o g r a p h e r . J i m m y G o s n e l l Location Silos Community – Building No. 6 Remarks Installing Geo-Seal Base upon subsurface. Silos Community Site 121 Lancaster Street, Charlotte, NC Project #: 1353-12-060 Sheet 2 of 2 9751 Southern Pine Blvd. Charlotte, NC 28273 Photo 3 D a t e : 1 2 /1 1 /2 0 1 2 P h o t o g r a p h e r . J i m m y G o s n e l l Location Silos Community – Building No. 6 Remarks Smoke testing after Geo-Seal Core spray-applied to Base and prior to Bond Layer being installed.