HomeMy WebLinkAbout21010_Reman Properties_UST Inspeciton Rpt-10,000 gallon diesel_20140226 Page 1 of 5 2/26/2014 6:47 PM North Carolina Department of Environment and Natural Resources Underground Storage Tank NC Printed: 2/26/2014 6:46 PM Inspection Result: Failed Inspection Date: 2/26/2014 Partial Inspection: No Arrive and Depart Times: 12:20 PM-12:50 PM Facility ID: 0-0-0000032432 Inspector Pam Harrelson Facility Name TOWNSENDS, INC Insp. Type Compliance Facility Address 270 MONCURE ROAD PITTSBORO, NC 27312 Chatham County Facility Located Reason(s) Routine Compliance Location 35.704468, -79.176041 Permit Exp. 9/30/2011 CONTACTS Contact Type Contact Information Regulatory Owner since 12/1/2010 OMNTRON USA LLC , P O BOX 370 PITTSBORO, NC 27312 Manager since 10/10/2002 ROGER MASHBURN, 270 MONCURE ROAD PITTSBORO, NC 27312, Phone: (919) 663-2050 Owner since 1/1/1986 TOWNSENDS, INC , 1100 E 3RD ST/PO BOX 709 SILER CITY, NC 27344, Phone: (919) 663-2050 OWNERSHIP CHANGE New Owner Change Date Basis Transfer of Ownership Form (UST-15) Submitted Yes 3/30/2010 TAX RECORDS No EMERGENCY RESPONSE Emergency Response Operator at inspection is listed in training log? No Emergency Response Operator log (UST-26) onsite and completed with names of trained employees? No OTHER PARTICIPANTS Name Organization INSPECTOR COMMENTS Type Date Comment Facility 2/26/2014 FACILITY WAS BOUGHT OUT OF BANKRUPTCY FROM TOWNSENDS FARMS, INC. IN DECEMBER 2010. FACILITY CLOSED IN OCTOBER 2011. Corr. Prot. 2/26/2014 NO ELECTRICTY. RECTIFIER READING ZERO FOR VOLTS AND AMPS. SYSTEM HAS BEEN INTEMPORARY CLOSURE SINCE OCTOBER 2011. TANKS AND PIPING INFORMATION Tanks Tank #1(1) Tank ID 1 TIMS Tank ID 1 Is tank registered? Yes Date tank installed 2/20/1961 Capacity of Tank in Gallons 10000 Tank / Product use Motor Fuel Product stored in Tank Diesel if gasoline, Detail If hazardous substance, CAS# or description If other, description Tank Status Temporarily Closed Facility ID: 0-0-0000032432 Page 2 of 5 2/26/2014 6:47 PM Tanks Tank #1(1) Tank closure report submitted Date tank last operated 10/31/2011 Inches of product in Tank 0.000000 Manifolded Tank No Manifolded with tanks New Tank System installed in accordance with NC or MI Tank Construction Material (DW required after 11/1/07) Single Wall Steel If other, description Tank Manufacturer/Model Unknown If other, describe Tank material verified by Date Pipe Installed 2/20/1961 Was UST Piping Installed on or after 11/1/2007? No Piping Construction Material (DW required after 11/1/07) Single Wall FRP If other, description Pipe Manufacturer/Model Unknown If other, describe Pipe material verified by If E-blend > 10% or Biodiesel Blend > 20%; Was UST-20 completed and approved? CORROSION PROTECTION Tank Corrosion Protection Tank #1(1) DWM notified of current CP method No Integrity assessment performed after 3/1/06 No CP Method 1 Impressed Current if other, Description CP Installation Date 4/1/1993 CP Method 2 if other, Description CP Installation Date Flex Connector , Piping Extensions, and/or other metal fittings Present Elbow Flex connector isolated from ground N/A Source of verification of CP for Flex Connectors, piping extensions and/or other metal fittings Visual if other, Description Submersible pump (STP) is isolated from ground No Piping extensions and/or other metal fittings are isolated from ground No Flex connector, STP and/or other metal fittings protected from corrosion No Corrosion protection method Impressed Current Flex connector , Piping extensions, and/or other metal fittings CP Installation Date 4/26/1993 Dielectric Coating Installed (If tank installed after 12/22/88 N/A Pipe Corrosion Protection Tank #1(1) DWM notified of current CP method Yes CP method FRP Piping if other, Description CP Installation Date 4/1/1993 Dielectric Coating Installed (If piping installed after 12/22/88 Yes CP Conclusions CP Requirements Met? No Issues Permanently close the UST system (MT1H) Impressed Current Systems System # 1 Applies to Tanks #1(1) Current voltage 0.0000 Current Amperage 0.0000 Facility ID: 0-0-0000032432 Page 3 of 5 2/26/2014 6:47 PM Impressed Current Systems System # 1 Last three 60-day readings available No System operating properly No If no, select all that apply System disabled or not operational If other, describe Hour Meter Reading? 57042 Hour meter Installed Yes CP Test No CP Test Results Provided SPILL PREVENTION Has DWM been notified of spill methods? Yes Spill/Overfill Details Tank #1(1) Is a drop tube present? No Type of Stage I vapor recovery? Coaxial Local Fill Tank #1(1) Does Tank have a Remote Fill? No Spill Protection Catchment Basin Is spill prevention equipment provided and verified? N/A Spill bucket is double-walled? (If installed after 11/1/07) N/A Spill bucket is isolated or made of non-corroding materials? (If installed after 11/1/07) N/A Date spill prevention provided 4/1/1993 Is spill prevention operating properly? No If No, select all that apply N/A If other, describe OVERFILL PREVENTION Has DWM been notified of overfill methods? Yes Overfill Control Tank #1(1) Is overfill prevention equipment provided and verified? Yes Date overfill control provided 4/1/1993 Type of overfill equipment Auto Shutoff Device Source of information for overfill control verification Visual observation If other, describe Is overfill control operating properly? Yes If No, select all that apply If other, describe Annual overfill check date (If installed after 11/1/07)(UST-22A) Annual overfill check results(UST-22A) SITING AND SECONDARY CONTAINMENT Siting And Sec.Containment-General Tank #1(1) UST system upgraded with corrosion protection, spill and overfill before 1/1/91? No UST system and/or piping are located within siting and secondary containment areas? No LEAK DETECTION General Tank #1(1) DWM notified of leak detection method? No Piping type Pressurized System Suction Check Type Type LLD present. MLLD Facility ID: 0-0-0000032432 Page 4 of 5 2/26/2014 6:47 PM General Tank #1(1) Tank – Primary leak detection method Not Required Tank - if other, specify Tank – Secondary leak detection method Tank - if other, specify Piping - Primary leak detection method Not Required Piping - if other, specify Piping - Secondary leak detection method Piping - if other, specify Facility ID: 0-0-0000032432 Page 5 of 5 2/26/2014 6:47 PM TEMPORARY CLOSURE Temporary Closure Temporary Closure Requirements Met? No Issues CP system not maintained: Permanently close UST System (CL3:A7) TRANSPORTER/FUEL DELIVERY INFORMATION Delivery Information Tank #1(1) All deliveries made to permitted tanks SITE DIAGRAM