Loading...
HomeMy WebLinkAboutCentral Ave Apts_BF Additional Assmt Rpt Via Email December 11, 2015 NC Department of Environmental Quality – Brownfields Program 1646 Mail Service Center Raleigh, NC 27699-1646 Attention: Mr. Jim Rudder Re: Brownfields Additional Assessment Report Central Avenue Apartments Charlotte, North Carolina Brownfields ID 19032-15-60 H&H Job No. DPJ-001 Dear Jim: 1.0 Introduction and Background In accordance with our authorized scope of work, Hart & Hickman, PC (H&H) has completed additional assessment activities for the Central Avenue Apartments project located at 1931-2027 Central Avenue (Site) in Charlotte, Mecklenburg County, North Carolina (Figure 1). This site is currently in the North Carolina Brownfields Redevelopment Now Program (Brownfields Project #19032-15-60). The proposed future use is multi-family residential. The Site is comprised of six parcels totaling approximately 1.96 acres and is currently developed with a commercial/residential building that contains 4,576 square feet and an automotive service building that is 7,400 square feet. H&H completed a Phase I Environmental Site Assessment (ESA) for the six parcels in March 2015. Based on the findings of the Phase I ESA, H&H identified several Recognized Environmental Conditions (RECs) associated with the site. Mr. Jim Rudder December 11, 2015 Page 2 S:\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\BFAddReport.docx On June 4 and 5 and June 8 and 9, 2015, H&H completed initial Brownfields assessment activities at the site. The assessment activities included the advancement and sampling of soil borings and temporary monitoring wells to assess for the potential of a release related to the historical use of 2027 Central Avenue, to further define the petroleum hydrocarbon groundwater impacts associated with 2013 Central Avenue, and to assess potential for site impacts from the adjacent off-site 7- Eleven Store property. Additionally, soil gas (SG) sampling was completed to evaluate potential risk for vapor intrusion from petroleum hydrocarbons in groundwater beneath the site. The results of the soil sampling indicated a concentration of TPH-DRO above the North Carolina Department of Environmental Quality (DEQ) Action Level of 10 mg/kg in one soil sample. No volatile organic compounds (VOCs) or semi-VOCs (SVOCs) were detected above the laboratory reporting limits in this sample or the other soil samples. The results of the groundwater samples collected from two temporary monitoring wells indicated various VOC concentrations above their respective 15A NCAC 2L Groundwater Quality Standards (2L Standards) and the DEQ Residential Vapor Intrusion Groundwater Screening Levels (GWSLs). Additionally, laboratory analytical results for the soil gas samples indicated that VOCs were detected above DEQ Residential Soil Gas Screening Levels (SGSLs). The results of the Brownfields assessment activities were presented in H&H’s Brownfields Assessment Report dated July 23, 2015. Following review of the report, DEQ requested that additional soil gas and groundwater sampling be conducted downgradient of the site. A Brownfields Additional Assessment Work Plan was sent to DEQ on September 16, 2015. The work plan was approved by DEQ via email on September 28, 2015. Additional assessment sampling methodology, results, and conclusions are presented in the following sections. Mr. Jim Rudder December 11, 2015 Page 3 S:\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\BFAddReport.docx 2.0 Assessment Activities 2.1 Groundwater Assessment Activities On June 4 and 5, 2015, temporary monitoring well TMW-6 was installed on the adjacent 2020 Hamorton Place property and temporary monitoring well TMW-7 was installed on the adjacent 2028 Hamorton Place property (Figure 2). The temporary monitoring wells were installed to help define the downgradient extent of the petroleum groundwater plume. The temporary wells were installed with a DPT rig and constructed of 1-inch diameter PVC casing and with a 15 ft section of 10 slot well screen. Well construction specifics are presented in Table 1. Boring logs, temporary well construction records, and well abandonment records are included in Appendix A. Following installation, the wells were developed until readings of pH, conductivity, and temperature stabilized. Once stabilization was reached, groundwater samples were collected and placed in an iced cooler. The samples were delivered under standard chain-of-custody protocol to Prism Laboratories, Inc. for analysis of VOCs by EPA Method 8260. On October 7, 2015, H&H obtained top of casing (TOC) elevations and gauged the new temporary monitoring wells and existing permanent monitoring wells. No free product was detected in any of the monitoring wells (Table 1). 2.2 Soil Gas Sampling Activities To assess the potential for vapor intrusion into off-site buildings, four SG sample points were installed at the locations shown on Figure 3. The SG points were installed as described below and were sampled in general accordance with the DEQ Vapor Intrusion Guidance dated April 2014 (VI Guidance). The soil gas sample points SG-9 and SG-12 were installed 5 to 7 ft above the Mr. Jim Rudder December 11, 2015 Page 4 S:\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\BFAddReport.docx groundwater table using a direct push technology (DPT) drill rig. Due to limited drill rig access, soil gas sample points SG-10 and SG-11 were installed to depths of approximately 8 to 10 feet bgs using a decontaminated stainless steel hand auger. Soil borings were described for lithologic purposes, observed for the presence of staining and odors, and field-screened for the presence of VOCs with a calibrated photo-ionization detector (PID). Boring logs are presented in Appendix A. Each vapor monitoring point was constructed with a 6-inch stainless steel sampling point at the final depth. Teflon® tubing was secured to the screen and extended to the ground surface. Well filter sand was placed around the annulus of the screened interval of the sample point, and extended to approximately 6 inches above the top of the screen interval. A bentonite seal was placed above the sand pack to grade and hydrated. The soil gas sample points were allowed to cure for a minimum of 12 hours prior to sampling. Prior to sampling, a leak check was conducted at each SG point by constructing a shroud around the sampling point and flooding the air within the shroud with helium (He) gas until a He atmosphere of 75% to 100% was achieved. A He gas detector was used to measure the % He within the shroud. Once the levels within the shroud reached near saturation concentrations, vapor from the monitoring point was purged and collected into a Tedlar® bag using a three way syringe. Following the purge of vapor into the Tedlar® bag, the contents of the bag were analyzed using the field He gas detector to ensure that He concentrations were less than 10% of the concentration detected in the shroud. Following successful field leak checks using He, vapor samples were collected from each sampling location into 1.4-liter Summa canisters for laboratory analysis. The Summa canisters were filled slowly using a lab-set airflow regulator over a period of approximately 60-65 minutes (less than 200 mL/min). As part of the testing, H&H collected measurements of ambient temperature at the beginning, middle, and end of the sampling day. Mr. Jim Rudder December 11, 2015 Page 5 S:\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\BFAddReport.docx The Summa canisters were shipped to Con-Test Analytical Laboratory, a North Carolina certified laboratory, under standard chain-of-custody protocol for analysis of VOCs by EPA Method TO- 15. 2.3 Well Abandonment and Investigation Derived Waste Because significant soil impacts were not encountered, soil cuttings generated during the additional assessment activities were spread on-site. Each boring was abandoned with bentonite and/or grout and the ground surface was patched to match the surrounding area. The temporary wells were abandoned in accordance with North Carolina regulations on October 12, 2015. Well abandonment records are included in Appendix A. 3.0 Assessment Results 3.1 Groundwater Sampling Results Results of the groundwater samples collected from TMW-6 and TMW-7 indicated VOC concentrations above the 2L Groundwater Standards. Additionally, 1,2,4-trimethylbenzene, benzene, ethylbenzene, toluene, and total xylenes were detected in these wells above the DEQ Residential Vapor Intrusion Groundwater Screening Levels (GWSLs). Naphthalene also was detected in TMW-6 above the Residential Vapor Intrusion GWSL. Concentrations in groundwater are shown on Figure 2. A summary of the groundwater analytical data is provided in Table 2, and the laboratory analytical report is included in Appendix B. 3.2 Soil Gas Sampling Results Laboratory analytical results for the soil gas samples indicate that benzene, ethylbenzene, hexane, methylene chloride, naphthalene, toluene, tetrachloroethylene, 1,2,4-trimethylbenzene, and xylenes were detected above DENR Residential Soil Gas Screening Levels (SGSLs). No other Mr. Jim Rudder December 11, 2015 Page 6 S:\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\BFAddReport.docx VOCs were detected in the soil gas samples above specified DENR Residential SGSLs. A summary of the soil gas vapor detections are provided in Table 3 and presented in Figure 3. The laboratory analytical report is included in Appendix B. 4.0 Summary and Conclusions H&H completed groundwater and soil gas assessment activities at the Central Avenue Apartments Brownfields site located in Charlotte, Mecklenburg County, North Carolina. The assessment activities included the collection and analysis of two groundwater samples and four soil gas samples. The results of the assessment activities are summarized below. • VOCs were detected above 2L Groundwater Standards in two temporary monitoring wells located downgradient of the site. Additionally, 1,2,4-trimethylbenzene, benzene, ethylbenzene, toluene, and total xylenes were detected in both wells and naphthalene was detected in one well above the DEQ Residential Vapor Intrusion GWSLs. • Benzene, ethylbenzene, hexane, methylene chloride, naphthalene, toluene, tetrachloroethylene, 1,2,4-trimethylbenzene, and xylenes were detected above DENR Residential SGSLs in soil gas samples located downgradient of the site. No other VOCs were detected in the soil gas samples above specified DENR Residential SGSLs. Based upon the results of the groundwater and soil gas assessment activities, vapor intrusion could be a cause for concern to the off-site residential buildings and should be further evaluated. Based on discussions with the Brownfields Program, H&H understands that any additional off-site assessments will be completed by the DEQ Underground Storage Tank (UST) Section. Mr. Jim Rudder December 11, 2015 Page 7 S:\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\BFAddReport.docx H&H appreciates the opportunity to work with you on this project. If you have any questions or require additional information, please do not hesitate to contact us at 704-586-0007. Sincerely, Hart & Hickman, PC Stephen R. Libbey, PG Project Manager cc: Mr. D. Porter Jones (via email) Table 1 Summary of Groundwater Elevation Mesurements Central Avenue Apartments Brownfields Charlotte, North CarolinaH&H Job No. DPJ-001 \\hhfs01.harthickman.local\masterfiles\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\GW Table12/11/2015 Hart & Hickman, PC Monitoring DTW DTP DTW DTP Well ID (ft)(ft)(ft)(ft) Jun-15 Jun-15 Jun-15 Oct-15 Oct-15 Oct-15 MW-1 35 15-35 100.00 28.43 --71.57 28.43 --71.57 MW-2 35 15-35 98.86 25.94 --72.92 25.94 --72.92 MW-3 35 15-35 99.40 27.10 --72.30 27.10 --72.30 MW-4 35 15-35 99.68 27.93 --71.75 27.93 --71.75 MW-5 40 35-40 98.52 27.67 --70.85 27.67 --70.85 MW-6 40 25-40 99.73 28.40 --71.33 28.40 --71.33 MW-7 40 25-40 99.40 28.25 --71.15 28.25 --71.15 MW-8 40 25-40 98.46 28.58 --69.88 28.58 --69.88 MW-9 28 13-28 93.68 24.89 --68.79 24.89 --68.79 SB-1/TMW-1 38 23-38 97.49 32.03 --65.46 SB-5/TMW-2 39.5 24.5-39.5 97.27 30.50 --66.77 TMW-3 35 20-35 101.35 27.73 --73.62 TMW-4 38 23-38 95.53 30.25 --65.28 TMW-5 38 23-38 102.02 31.66 --70.36 TMW-6 25 10-25 80.78 15.89 --64.89 TMW-7 25 10-25 85.98 21.05 --64.93 Notes: TOC = Top of PVC well casing; DTW = Depth to water from TOC; DTP = Depth to product from TOC; ft bgs = Feet below ground surface; -- = No measurable free product; NI = Not Installed; ABN = Abandoned Total Depth (ft bgs) Screen Interval (ft bgs)TOC Elevation (msl) Relative Groundwater ElevationRelative Groundwater Elevation ABN ABN NI NI ABN ABN ABN Table 2 Summary of Groundwater Analytical Data Central Avenue Apartments Brownfields Charlotte, North Carolina H&H Job No. DPJ-001 \\hhfs01.harthickman.local\masterfiles\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\GW Table 12/11/2015 Hart & Hickman, PC Sample ID TMW-6 TMW-7 Sample Date 10/2/2015 10/2/2015 Units (µg/L)(µg/L)(µg/L)(µg/L) VOCs (8260B) 1,2,4-Trimethylbenzene 260 1,600 400 5.8 1,3,5-Trimethylbenzene 82 <500 400 NS Benzene 4,700 14,000 1 15.9 Ethylbenzene 560 2,400 600 34.9 Isopropylbenzene 560 <500 70 NS Naphthalene 310 <1,000 6 34.8 Styrene 34 <500 70 1,860 Toluene 4,700 35,000 600 3,840 Total Xylene 2,220 11,000 500 98.5 Notes: Only those compounds detected in at least one sample shown above 1) 15A North Carolina Administrative Code 2L Groundwater Standards 2) Division of Waste Management Residential Vapor Intrusion Groundwater Screening Level Bold indicates an exceedance of the NCAC 2L Standard Highlighted indicates an exceedance of the Division of Waste Management Residential Vapor Intrusion Groundwater Screening Level. Method number follows parameter in parenthesis VOCs = volatile organic compounds; NS = screening criteria not specified µg/L = micrograms per liter 2020 Hamorton Place 2028 Hamorton Place 15A NCAC 2L1 DWM VI Residential Groundwater Screening Level2 Screening Critera Table 3 Summary of Soil Gas Analytical Data Central Avenue Apartments Brownfields Charlotte, North Carolina H&H Job No. DPJ-001 \\hhfs01.harthickman.local\masterfiles\AAA-Master Projects\DPJ Residential LLC (DPJ)\BF Assessment\Additional GW Vapor Assessment\Report\SG Data Table 12/11/2015 Hart & Hickman, PC Screening Criteria 2020 Hamorton Place 2101 Central Avenue 1427 Landis Avenue 2028 Hamorton Place Sample ID SG-9 SG-10 SG-11 SG-12 Sample Date 10/1/2015 10/1/2015 10/1/2015 10/1/2015 Units (ug/m3)(ug/m3)(ug/m3)(ug/m3)(ug/m3) VOCs (TO-15) Acetone 216,000 <1,900 98 31 <1,900 Benzene 120 55,000 1.2 1.9 32,000 2-Butanone (MEK)34,800 <2,400 11 4.8 <2,400 Carbon Disulfide 4,870 120 1.6 1.3 96 Chloroform 40.7 <98 0.57 2.5 <98 Chloromethane 626 100 <1.1 1.1 <83 Cyclohexane 41,700 3,900 <0.92 <0.92 18,000 Dichlorodifluoromethane (Freon 12)695 87 1.6 1.7 <99 Ethanol NS <1,500 21 11 <1,500 Ethylbenzene 374 31,000 0.51 4.9 8,200 4-Ethyltoluene NS 5,200 0.50 5.7 1,300 Heptane NS 2,900 <1.1 6.8 12,000 Hexane 4,870 13,000 3.4 <38 79,000 Isopropanol 1,390 <2,000 <26 2.0 <2,000 Methylene Chloride 4,170 7,800 3.3 1.7 <690 Naphthalene 20.9 490 <1.4 0.87 63 Propylene 20,900 4,900 21 28 <1,400 Styrene 6,950 220 <1.1 <1.1 <85 Tetrachloroethylene 278 170 4.4 5.0 670 Toluene 34,800 49,000 12 58 13,000 Trichlorofluoromethane (Freon 11)4,870 180 1.6 1.6 <450 1,1,2-Trichloro-1,2,2-trifluoroethane (Freon 113)209,000 <610 2.1 1.6 52 1,2,4-Trimethylbenzene 48.7 26,000 1.2 7.3 2,500 1,3,5-Trimethylbenzene NS 6,000 0.26 1.8 1,500 Xylene, Total 695 87,000 2.86 23.3 21,600 Notes:1 NC Department of Environmental Quality (DEQ) Divison of Waste Management Residential Subslab and Exterior Soil Gas Screening Levels (September 2015) Only those compounds detected in at least one sample shown above Bold indicates an exceedance of the Residential Soil Gas Screening Level (SGSL) VOCs = volatile organic compounds; NS = screening criteria not specified; µg/m3 = micro grams per cubic meter DWM Residential SGSL1 SITE LOCATION MAP CENTRAL AVENUE APARTMENTS 1931-2027 CENTRAL AVENUE CHARLOTTE, NORTH CAROLINA DATE: JOB NO: REVISION NO: FIGURE NO: 12/11/2015 0 1DPJ-001 0 2000 4000 APPROXIMATE SCALE IN FEET N U.S.G.S. QUADRANGLE MAP 7.5 MINUTE SERIES (TOPOGRAPHIC) 2923 S. Tryon Street, Suite 100Charlotte, NC 28203704.586.0007(p) 704.586.0373(f) CHARLOTTE EAST, NORTH CAROLINA 1991 SITE MW-5 MW-8 MW-7MW-6MW-1 MW-4 MW-3 MW-2 RESIDENCE CENTRAL AVENUE 2013 CENTRAL AVENUE (095-077-12) MCLAMB GROUP (2101 CENTRAL AVENUE) 2027 CENTRAL AVENUE (095-077-13) PARTS WASHER MW-9 2020 Hamorton Place 2009 CENTRAL AVENUE (095-077-36) 2028 Hamorton Place 1427 Landis Avenue JOB NO. DPJ-001 REVISION NO. 0DATE: 12-11-15 FIGURE NO. 2 2923 South Tryon Street-Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(f) License # C-1269 / #C-245 Geology CENTRAL AVENUE APARTMENTS 1931-2027 CENTRAL AVENUE CHARLOTTE, NORTH CAROLINA GROUNDWATER SAMPLE LOCATIONS MAP LEGEND SITE PROPERTY BOUNDARY APPROXIMATE EXTENT OF CELLAR APPROXIMATE FUTURE BUILDING FOOTPRINT POLE MOUNTED TRANSFORMER MONITORING WELL LOCATION TEMPORARY MONITORING WELL LOCATION &21&(175$7,21 ȝJ/ TMW-6 BENZENE 160 SAMPLE ID NOTES: 1.ONLY COMPOUNDS EXCEEDING THE 15A NCAC 2L GROUNDWATER STANDARDS IN AT LEAST ONE SAMPLE SHOWN. 2.HIGHLIGHTED INDICATES EXCEEDANCE OF RESIDENTIAL VAPOR INTRUSION GROUNDWATER SCREENING LEVEL. COMPOUND TMW-6 1,2,4-TRIMETHYLBENZENE 260 BENZENE 4,700 ETHYLBENZENE 560 ISOPROPYLBENZENE 560 NAPHTHALENE 310 TOLUENE 4700 XYLENES 2,220 TMW-7 1,2,4-TRIMETHYLBENZENE 1,600 BENZENE 14,000 ETHYLBENZENE 2,400 ISOPROPYLBENZENE <500 NAPHTHALENE <1,000 TOLUENE 35,000 XYLENES 11,000 MW-5 MW-8 MW-7MW-6MW-1 MW-4 MW-3 MW-2 RESIDENCE CENTRAL AVENUE 2013 CENTRAL AVENUE (095-077-12) MCLAMB GROUP (2101 CENTRAL AVENUE) 2027 CENTRAL AVENUE (095-077-13) PARTS WASHER MW-9 2020 Hamorton Place 2009 CENTRAL AVENUE (095-077-36) 2028 Hamorton Place 1427 Landis Avenue JOB NO. DPJ-001 REVISION NO. 0DATE: 12-11-15 FIGURE NO. 3 2923 South Tryon Street-Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(f) License # C-1269 / #C-245 Geology CENTRAL AVENUE APARTMENTS 1931-2027 CENTRAL AVENUE CHARLOTTE, NORTH CAROLINA SOIL GAS SAMPLE LOCATIONS MAP LEGEND SITE PROPERTY BOUNDARY APPROXIMATE EXTENT OF CELLAR APPROXIMATE FUTURE BUILDING FOOTPRINT MONITORING WELL LOCATION SOIL GAS POINT &21&(175$7,21 ȝJP3) SAMPLE ID NOTES: 1.ONLY COMPOUNDS EXCEEDING THE DENR RESIDENTIAL SGSLS IN EACH SAMPLE SHOWN. 2.SGSL = DENR SOIL GAS SCREENING LEVEL. SG-1 BENZENE 350 CONTAMINANT SG-9 BENZENE 55,000 ETHYLBENZENE 31,000 HEXANE 13,000 METHYLENE CHLORIDE 7,800 NAPHTHALENE 490 TOLUENE 49,000 1,2,4-TMB 26,000 XYLENES 87,000 SG-12 BENZENE 32,000 ETHYLBENZENE 8,200 HEXANE 79,000 NAPHTHALENE 63 PCE 670 TOLUENE 13,000 1,2,4-TMB 2,500 XYLENES 21,600 SG-11 VOCs <SGSLsSG-10 VOCs <SGSLs Appendix A Boring Logs Organic grassy Topsoil Moist, Slightly stiff, dark brown sandy SILT Slightly moist, medium, red and brown SILT Moist, medium, dull orange and brown SILT Very moist, medium, dull orange and tan SILT with traceclay and no odor Wet, medium, tan and gray SILT with strong odor Wet, very stiff, tan and gray SILT with saprolite and strongodor Wet, hard, tan and gray SILT with saprolite and strongodor Bottom of borehole at 25.0 feet. 0.1 1.4 1.6 1.6 2.8 4.2 25.9 25.7 954.5 729.8 556.3 303.1 0 0 0 0 0 0 0 0 0 0 0 0 1" PVCRiser BentoniteSeal FIlter Sand 0.0100"Slotted Screen FIlter Sand DRAWN BY:KJW BORING COMPLETED:10/1/15 DRILLING CONTRACTOR:Geologic Exploration Remarks: DRILL RIG/ METHOD:Geoprobe 8040DT / HA/DPT SAMPLING METHOD:DPT Sleeves Installed temporary monitoring well,screened from 10-25 feet bgs. BORING STARTED:10/1/15 LOGGED BY:KJW TOTAL DEPTH: 25 ft. TOP OF CASING ELEV: DEPTH TO WATER: DE P T H (f t ) DE P T H (f t )MATERIAL DESCRIPTION LI T H O L O G Y SA M P . BK G . BL O W CO U N T S (N V A L U E ) WELL DIAGRAM OV A ( p p m ) RE C O V E R Y ( % ) SA M P L E T Y P E NU M B E R Sheet 1 of 1 BORING NUMBER TMW-6 PROJECT:Central Ave Brownfields JOB NUMBER:DPJ.001 LOCATION:Charlotte, NC WE L L L O G - H A R T H I C K M A N . G D T - 1 0 / 2 / 1 5 1 3 : 5 8 - S : \ A A A - M A S T E R G I N T P R O J E C T S \ D P J . 0 0 1 C E N T R A L A V E S E P T 2 0 1 5 . G P J 2923 South Tryon Street-Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(f) 3334 Hillsborough Street Raleigh, North Carolina 27607 919-847-4241(p) 919-847-4261(f) 0 5 10 15 20 25 0 5 10 15 20 25 Slightly moist, medium, dull red clayey SILT Moist, medium, dull red orange SILT Saturated, soft, dull red SILT with slight odor Very moist, slightly stiff, dull orange and brown SILT withodor Wet, slightly stiff, dull orange and brown SILT with odor Saturated, slightly stiff, dull orange and brown SILT withstrong odor Saturated, slightly stiff, dull orange and brown SILT withsaprolite and strong odor Bottom of borehole at 25.0 feet. 1.1 1.7 14.3 9.3 25.9 9.9 53.8 64.5 69.1 72 2716 1635 0 0 0 0 0 0 0 0 0 0 0 0 1" PVCRiser BentoniteSeal FIlter Sand 0.0100"Slotted Screen FIlter Sand DRAWN BY:KJW BORING COMPLETED:10/1/15 DRILLING CONTRACTOR:Geologic Exploration Remarks: DRILL RIG/ METHOD:Geoprobe 8040DT / HA/DPT SAMPLING METHOD:DPT Sleeves Installed temporary monitoring well,screened from 10-25 feet bgs. BORING STARTED:10/1/15 LOGGED BY:KJW TOTAL DEPTH: 25 ft. TOP OF CASING ELEV: DEPTH TO WATER: DE P T H (f t ) DE P T H (f t )MATERIAL DESCRIPTION LI T H O L O G Y SA M P . BK G . BL O W CO U N T S (N V A L U E ) WELL DIAGRAM OV A ( p p m ) RE C O V E R Y ( % ) SA M P L E T Y P E NU M B E R Sheet 1 of 1 BORING NUMBER TMW-7 PROJECT:Central Ave Brownfields JOB NUMBER:DPJ.001 LOCATION:Charlotte, NC WE L L L O G - H A R T H I C K M A N . G D T - 1 0 / 2 / 1 5 1 3 : 5 8 - S : \ A A A - M A S T E R G I N T P R O J E C T S \ D P J . 0 0 1 C E N T R A L A V E S E P T 2 0 1 5 . G P J 2923 South Tryon Street-Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(f) 3334 Hillsborough Street Raleigh, North Carolina 27607 919-847-4241(p) 919-847-4261(f) 0 5 10 15 20 25 0 5 10 15 20 25 Organic grassy Topsoil Moist, soft, dark brown gravelly SILT Moist, medium, dull red clayey SILT Slightly moist, medium, dull orange and tan SILT Moist, medium, dull orange and tan SILT Bottom of borehole at 11.5 feet. 2 3 3.9 3.3 3.1 3.9 0 0 0 0 0 0 DRAWN BY:KJW BORING COMPLETED:10/1/15 DRILLING CONTRACTOR:Geologic Exploration Remarks: DRILL RIG/ METHOD:Geoprobe 8040DT / HA/DPT SAMPLING METHOD:DPT Sleeves Installed soil gas point 11.5 feet bgs. BORING STARTED:10/1/15 LOGGED BY:KJW TOTAL DEPTH: 11.5 ft. TOP OF CASING ELEV: DEPTH TO WATER: DE P T H (f t ) DE P T H (f t )MATERIAL DESCRIPTION LI T H O L O G Y SA M P . BK G . BL O W CO U N T S (N V A L U E ) WELL DIAGRAM OV A ( p p m ) RE C O V E R Y ( % ) SA M P L E T Y P E NU M B E R Sheet 1 of 1 BORING NUMBER SG-9 PROJECT:Central Ave Brownfields JOB NUMBER:DPJ.001 LOCATION:Charlotte, NC WE L L L O G - H A R T H I C K M A N . G D T - 1 0 / 2 / 1 5 1 3 : 5 8 - S : \ A A A - M A S T E R G I N T P R O J E C T S \ D P J . 0 0 1 C E N T R A L A V E S E P T 2 0 1 5 . G P J 2923 South Tryon Street-Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(f) 3334 Hillsborough Street Raleigh, North Carolina 27607 919-847-4241(p) 919-847-4261(f) 0.0 2.5 5.0 7.5 10.0 0.0 2.5 5.0 7.5 10.0 Organic grassy Topsoil Moist, slightly stiff, dull red SILT Slightly moist, very stiff, dull red clayey SILT Moist, medium, dull red and tan SILT Moist, slightly stiff, dull red and orange SILT with no odor Bottom of borehole at 10.0 feet. 0 0.1 0 0.1 0.1 0 0 0 0 0 DRAWN BY:KJW BORING COMPLETED:10/1/15 DRILLING CONTRACTOR:Geologic Exploration Remarks: DRILL RIG/ METHOD:Hand Auger / HA SAMPLING METHOD:Auger Cuttings Installed soil gas point 10 feet bgs. BORING STARTED:10/1/15 LOGGED BY:KJW TOTAL DEPTH: 10 ft. TOP OF CASING ELEV: DEPTH TO WATER: DE P T H (f t ) DE P T H (f t )MATERIAL DESCRIPTION LI T H O L O G Y SA M P . BK G . BL O W CO U N T S (N V A L U E ) WELL DIAGRAM OV A ( p p m ) RE C O V E R Y ( % ) SA M P L E T Y P E NU M B E R Sheet 1 of 1 BORING NUMBER SG-10 PROJECT:Central Ave Brownfields JOB NUMBER:DPJ.001 LOCATION:Charlotte, NC WE L L L O G - H A R T H I C K M A N . G D T - 1 0 / 2 / 1 5 1 3 : 5 8 - S : \ A A A - M A S T E R G I N T P R O J E C T S \ D P J . 0 0 1 C E N T R A L A V E S E P T 2 0 1 5 . G P J 2923 South Tryon Street-Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(f) 3334 Hillsborough Street Raleigh, North Carolina 27607 919-847-4241(p) 919-847-4261(f) 0.0 2.5 5.0 7.5 10.0 0.0 2.5 5.0 7.5 10.0 Slightly moist, slightly stiff, reddish brown clayey SILT Moist, slightly stiff, reddish brown clayey SILT with blackmottling Moist, tan clayey SILT with black mottling and gravel Bottom of borehole at 8.0 feet. 0 0 0 0 0 0 0 0 DRAWN BY:KJW BORING COMPLETED:10/1/15 DRILLING CONTRACTOR:Geologic Exploration Remarks: DRILL RIG/ METHOD:Hand Auger / HA SAMPLING METHOD:Auger Cuttings Installed soil gas point 8 feet bgs. BORING STARTED:10/1/15 LOGGED BY:KJW TOTAL DEPTH: 8 ft. TOP OF CASING ELEV: DEPTH TO WATER: DE P T H (f t ) DE P T H (f t )MATERIAL DESCRIPTION LI T H O L O G Y SA M P . BK G . BL O W CO U N T S (N V A L U E ) WELL DIAGRAM OV A ( p p m ) RE C O V E R Y ( % ) SA M P L E T Y P E NU M B E R Sheet 1 of 1 BORING NUMBER SG-11 PROJECT:Central Ave Brownfields JOB NUMBER:DPJ.001 LOCATION:Charlotte, NC WE L L L O G - H A R T H I C K M A N . G D T - 1 0 / 2 / 1 5 1 3 : 5 8 - S : \ A A A - M A S T E R G I N T P R O J E C T S \ D P J . 0 0 1 C E N T R A L A V E S E P T 2 0 1 5 . G P J 2923 South Tryon Street-Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(f) 3334 Hillsborough Street Raleigh, North Carolina 27607 919-847-4241(p) 919-847-4261(f) 0.0 2.5 5.0 7.5 0.0 2.5 5.0 7.5 Slightly moist, medium, dull red clayey SILT Moist, medium, dull red and orange SILT Moist, very stiff dull orange and brown SILT with traceodor Bottom of borehole at 14.0 feet. 1.3 1.9 6.3 9.7 16.3 20.6 40.2 0 0 0 0 0 0 0 DRAWN BY:KJW BORING COMPLETED:10/1/15 DRILLING CONTRACTOR:Geologic Exploration Remarks: DRILL RIG/ METHOD:Geoprobe 8040DT / HA/DPT SAMPLING METHOD:DPT Sleeves Installed soil gas point 14 feet bgs. BORING STARTED:10/1/15 LOGGED BY:KJW TOTAL DEPTH: 14 ft. TOP OF CASING ELEV: DEPTH TO WATER: DE P T H (f t ) DE P T H (f t )MATERIAL DESCRIPTION LI T H O L O G Y SA M P . BK G . BL O W CO U N T S (N V A L U E ) WELL DIAGRAM OV A ( p p m ) RE C O V E R Y ( % ) SA M P L E T Y P E NU M B E R Sheet 1 of 1 BORING NUMBER SG-12 PROJECT:Central Ave Brownfields JOB NUMBER:DPJ.001 LOCATION:Charlotte, NC WE L L L O G - H A R T H I C K M A N . G D T - 1 0 / 2 / 1 5 1 3 : 5 8 - S : \ A A A - M A S T E R G I N T P R O J E C T S \ D P J . 0 0 1 C E N T R A L A V E S E P T 2 0 1 5 . G P J 2923 South Tryon Street-Suite 100 Charlotte, North Carolina 28203 704-586-0007(p) 704-586-0373(f) 3334 Hillsborough Street Raleigh, North Carolina 27607 919-847-4241(p) 919-847-4261(f) 0.0 2.5 5.0 7.5 10.0 12.5 15.0 0.0 2.5 5.0 7.5 10.0 12.5 15.0 Appendix B Laboratory Analytical Reports Page 1 of 14 Page 2 of 14 Page 3 of 14 Page 4 of 14 Page 5 of 14 Page 6 of 14 Page 7 of 14 Page 8 of 14 Page 9 of 14 Page 10 of 14 Page 11 of 14 Page 12 of 14 Page 13 of 14 Page 14 of 14 Page 1 of 26 Page 2 of 26 Page 3 of 26 Page 4 of 26 Page 5 of 26 Page 6 of 26 Page 7 of 26 Page 8 of 26 Page 9 of 26 Page 10 of 26 Page 11 of 26 Page 12 of 26 Page 13 of 26 Page 14 of 26 Page 15 of 26 Page 16 of 26 Page 17 of 26 Page 18 of 26 Page 19 of 26 Page 20 of 26 Page 21 of 26 Page 22 of 26 Page 23 of 26 Page 24 of 26 Page 25 of 26 Page 26 of 26