Loading...
HomeMy WebLinkAboutUniversity Ford Asbestos Report_20160726July 26, 2016 Mr. Peter McGrath Moore & Van Allen PLLC 100 North Tryon Street, Suite 4700 Charlotte, North Carolina 28202-4003 Reference: Report of Asbestos Survey 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A Dear Mr. McGrath: Atlantic Shores Environmental Services, Ltd. (ASE) has completed an asbestos survey at the above referenced property. The purpose of the testing was to determine the presence and general location of asbestos containing materials (ACM) within the renovation area. This report includes a summary of the project background information, our survey approach and sampling results, and conclusions and recommendations. PROJECT INFORMATION The site includes approximately 11.19 acres of developed land located in downtown Durham, North Carolina, adjacent to the west of the American Tobacco Historic District. Four structures currently occupy the site. A Ford dealership and Kia dealership currently occupy the property. The structures include: Ford Showroom/Office Space Building: This is an approximate 21,642 square-foot single-story cinderblock and steel building constructed on a slab foundation. The roof is a combination gabled shingle roof and flat rubber roof. This structure is utilized for both a showroom for University Ford (occupying the southeast half of the building) and office space (occupying the north-northwest half of the building) for University Ford employees. The building was reportedly built in 1973, with an addition to the north side of the building in 1984. Maintenance and Repair Building: This is a single story cinderblock and steel building encompassing approximately 33,894 square-feet, with a mezzanine located within the eastern portion of the building. This building was built in 1973 on a slab foundation with a metal roof. Atlantic Shores Environmental Services, Ltd. 154 Backhoe Road, L e land NC 28451 • P:(91 O) 3 71-5980 • F:(91 O) 3 71-6652 -A Woman Owned Business- Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A 2 Paint and Auto body Building: This building is a single story cinderblock and steel framed building encompassing approximately 16,200 square-feet in area. The structure was built in 1973 on a slab foundation with a metal roof. University Kia Showroom and Office Building: This building is a single-story cinderblock and steel framed building encompassing approximately 3,500 square feet in area. It is used as a showroom and office space for University Kia. According to the historical research conducted by ASE and the as-built drawing, the eastern approximately 1,400 square-feet portion of this building was originally constructed in 1973. The western portion of the building was constructed as an addition to the original building around 2010. The building is constructed on a concrete slab foundation and has a flat rubber roof. SCOPE OF SERVICES The asbestos survey was performed by Cheryl Moody (North Carolina Asbestos Inspector No.12067) and Mr. Elliot Swain of ASE on June 9 and 10, 2016. The survey consisted of observing the accessible areas of the project area for the presence of suspect materials, which may contain asbestos. The survey involved detecting both friable materials (materials which can be pulverized or reduced to a powder by hand pressure when dry) and nonfriable materials (materials which pose a hazard when sawn, sanded, drilled or pulverized). Homogeneous materials (based on material type, color, texture, etc.) were identified in various functional spaces (bathroom, etc.) during the survey. In order to determine if the suspect materials observed during the visual survey contained asbestos, representative bulk samples were collected and placed in sealed packages. Sampling was performed to National Emission Standard for Hazardous Air Pollutants (NESHAP) protocols. Three samples of each suspect surfacing asbestos material or thermal system insulation (TSI) and one to two samples of each suspect miscellaneous asbestos material were collected for laboratory analysis. One hundred and eighty eight (188) bulk samples were collected during the survey and submitted to EMSL Analytical, Inc. in Mooresville, North Carolina for analysis using the EPA recommended method of Polarized Light Microscopy (PLM) coupled with dispersion staining (Method No. EPA 600/M4-020-82, Dec. 1982). EMSL participates in the National Voluntary Laboratory Accreditation Program (NVLAP). Their NVLAP accreditation number is 200671-0. Several samples were layered and analyzed as multiple samples. A positive stop approach was used to reduce sample costs. The EPA defines an asbestos-containing material as a material containing one percent or more asbestos. EPA regulations require that multiple samples of each homogeneous area be collected for laboratory analysis. If the first sample in each set of homogeneous materials is determined to be asbestos-containing (1% or more asbestos), then the remaining samples in that set are presumed to be asbestos-containing and the laboratory does not analyze them. Therefore, the laboratory analyzed 209 samples. In addition, six (6) samples were re-analyzed by the 400-point count method (with or without gravimetric reduction) in an attempt to reduce the quantity of material requiring abatement prior to renovation or demolition. Ford Showroom/Office Building Sampled materials from this building consisted of various floor tiles and mastic, wallboard, drywall/joint compound, 2x2’ and 2x4’ ceiling tiles, exterior surfacing, window caulk, carpet mastic, baseboard mastic, and roofing materials. Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A 3 Maintenance and Repair Building: Sampled materials from this building consisted of various floor tiles and mastic, HVAC duct tape, drywall/joint compound, 2x4’ ceiling tiles, door sealant, wall joint sealant, window sealant and roofing materials. Paint and Auto body Building: Sampled materials from this building consisted of floor tile and mastic, sink sealant, drywall/joint compound, 2x4’ ceiling tiles, door sealant, baseboard mastic and roofing material. University Kia Showroom and Office Building: Sampled materials from this building consisted of floor tile and mastic, drywall/joint compound, 2x4’ ceiling tiles, exterior surfacing, exterior paneling, exterior caulk, baseboard mastic, and roofing materials. RESULTS The results have been presented in the attached Table 1. The EPA defines an asbestos-containing material as a material containing one percent or more asbestos. ASE has listed both asbestos-containing materials (>1% asbestos) and materials that contain trace amounts of asbestos (<1% asbestos) in the table. Approximate quantities of asbestos containing building materials have been included in the table. However, these quantities are rough estimates and should be quantified independently by any abatement contractor. It should be noted that destructive testing was not conducted as part of this survey. Ford Showroom/Office Building: Asbestos containing building materials were not identified in the Ford Showroom/Office Building. Maintenance and Repair Building: Asbestos containing building materials identified in the Maintenance and Repair Building include: •Floor tile mastic located beneath the 12x12 tile in the parts department. •HVAC duct wrap located upstairs in the storage area. •12x12 floor tile and mastic located in the shop technician locker room. •Exterior sealant located between the metal exterior and cinderblock. •Interior sealant located between the interior cinderblock wall and door on the southeast corner of the shop. Paint and Auto body Building: Asbestos containing building materials identified in the Paint and Auto Body Building included: •Exterior sealant located on the south entrance door. •Penetration sealant located on fume hoods on the roof of the building. •Roof sealant located down the length of the roof and on penetrations. All penetration sealant on this roof should be assumed asbestos containing. Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A 4 University Kia Showroom and Office Building: Asbestos containing building material was not identified in the University Kia Showroom and Office Building. CONCLUSIONS AND RECOMMENDATIONS Based on the results of our sampling, asbestos containing materials were identified at the site. The material consists of as various 12x12 floor tile and mastic, interior and exterior sealants (this includes roofing penetration sealants), and HVAC duct wrap. If the above referenced asbestos materials are to be disturbed by renovations or demolition, the asbestos must be removed in accordance with EPA, State of North Carolina and OSHA asbestos regulations. The State of North Carolina, Health Hazards Control Unit (HHC) has specific regulations that must be adhered to during asbestos removal/abatement projects. The EPA and State of North Carolina defines an asbestos-containing material as a material containing one percent or more asbestos. The EPA and State of North Carolina do not regulate a material containing less than one percent asbestos and the abatement of the material is not required prior to renovation of the structure. Since the structure is scheduled for renovation and or demolition, we recommend the following: 1.Abate the friable and non-friable asbestos-containing materials in the structures prior to renovation or demolition. 2.ASE can perform a final visual inspection after asbestos removal is completed and conduct clearance testing during your abatement, as needed. You should be aware that stringent requirements are imposed upon anyone renovating or demolishing a structure in which ACM will be disturbed. This work must be performed in accordance with OSHA asbestos regulations, 29 CFR 1910 & 1926, and NESHAP asbestos regulations 40 CFR 61, subpart M. North Carolina regulations require the accreditation of personnel who work in the asbestos field and notification and permitting fees for asbestos removal projects. There is a 10 working day notification period required prior to abatement of more than 160 square-feet or 260 linear-feet of regulated asbestos in a facility. Failure to take proper precautions and actions to protect human health and the environment can result in penalties, danger to personnel, and construction delays. Please note that this document is not a specification for asbestos removal. It does not contain means and methods for asbestos abatement. If you are planning an asbestos abatement project, please contact ASE to discuss the requirements. Use of this document without the express written consent of ASE is at the sole risk of the user and or/abatement contractor. This report summarizes our evaluation of the conditions observed at the site. The findings prepared by ASE are based upon testing performed in the building. Additional ACM may exist (undetected) in other areas due to their inaccessibility or due to the limited nature of our testing. Our recommendations are based on the guidelines presented in EPA, State of North Carolina or OSHA asbestos regulations. Use of this document without the express written consent of ASE is at the sole risk of the user. ASE Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A 5 appreciates the opportunity to provide our environmental services for this project. If you have questions or need additional information, please contact us at (910) 371-5980. Respectfully, ATLANTIC SHORES ENVIRONMENTAL SERVICES, LTD. Cheryl J. Moody, REM, CMRS, CIEC Elliot Swain Principal Scientist Staff Scientist NC Asbestos Inspector No. 12067 Attachments: Bulk Asbestos Analysis Sheets Asbestos Chain of Custody Photographs Table Figure EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Attention:Phone:Cheryl Moody (910) 371-5980 Fax:Atlantic Shores Environmental Svcs., Ltd (910) 371-6652 Received Date:154 Backhoe Road 06/09/2016 5:00 PM Analysis Date:Leland, NC 28451 06/10/2016 Collected Date:06/09/2016 Project:1272A Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type S-1A-Floor Tile 291603738-0001 None DetectedNon-fibrous (Other)100%Blue Non-Fibrous Homogeneous University Ford Showroom Building - Blue 12x12 FT Female BR S-1A-Mastic 291603738-0001A None DetectedNon-fibrous (Other)98%Cellulose2%Tan/Clear Fibrous Homogeneous University Ford Showroom Building - Blue 12x12 FT Female BR S-1B-Floor Tile 291603738-0002 None DetectedNon-fibrous (Other)100%Cellulose<1%Blue Non-Fibrous Homogeneous University Ford Showroom Building - Blue 12x12 FT Male BR Insufficient amount of mastic S-2A 291603738-0003 None DetectedNon-fibrous (Other)93%Cellulose Glass 5% 2% Brown/Gray Fibrous Homogeneous University Ford Showroom Building - Tile 12x12 Under S-1AB FT S-2B 291603738-0004 None DetectedNon-fibrous (Other)75%Cellulose Glass 15% 10% Brown Fibrous Homogeneous University Ford Showroom Building - Tile 12x12 Under S-1AB FT S-3A-Floor Tile 291603738-0005 None DetectedNon-fibrous (Other)98%Cellulose2%White Fibrous Homogeneous University Ford Showroom Building - White 12x12 FT Storage Closet S-3A-Mastic 291603738-0005A None DetectedNon-fibrous (Other)97%Cellulose3%Tan Fibrous Homogeneous University Ford Showroom Building - White 12x12 FT Storage Closet S-3B-Floor Tile 291603738-0006 None DetectedNon-fibrous (Other)98%Cellulose2%White Fibrous Homogeneous University Ford Showroom Building - White 12x12 FT Storage Closet S-3B-Mastic 291603738-0006A None DetectedNon-fibrous (Other)92%Cellulose8%Brown Fibrous Homogeneous University Ford Showroom Building - White 12x12 FT Storage Closet S-4A 291603738-0007 None DetectedNon-fibrous (Other)78%Cellulose Glass 20% 2% White Fibrous Homogeneous University Ford Showroom Building - Tongue & Groove Wallboard Closet Inseparable texture/coating layer included in analysis S-4B 291603738-0008 None DetectedNon-fibrous (Other)78%Cellulose Glass 20% 2% White Fibrous Homogeneous University Ford Showroom Building - Tongue & Groove Wallboard Closet Inseparable texture /coating layer included in analysis Initial Report From: 06/13/2016 10:14:44 Page 1 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type S-4C 291603738-0009 None DetectedNon-fibrous (Other)77%Cellulose Glass 15% 8% Gray/White Fibrous Homogeneous University Ford Showroom Building - Tongue & Groove Wallboard Closet Inseparable texture /coating layer included in analysis S-5A-Floor Tile 291603738-0010 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous University Ford Showroom Building - Black Tile @ Closet Door S-5A-Mastic 291603738-0010A None DetectedNon-fibrous (Other)95%Cellulose5%Beige Fibrous Homogeneous University Ford Showroom Building - Black Tile @ Closet Door S-5B-Floor Tile 291603738-0011 None DetectedNon-fibrous (Other)100%Cellulose<1%Black Non-Fibrous Homogeneous University Ford Showroom Building - Black Tile @ Closet Door S-5B-Mastic 291603738-0011A None DetectedNon-fibrous (Other)98%Cellulose2%Tan Fibrous Homogeneous University Ford Showroom Building - Black Tile @ Closet Door S-6A-Floor Tile 291603738-0012 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous University Ford Showroom Building - White Tile 12x12 Hallway S-6A-Mastic 291603738-0012A None DetectedNon-fibrous (Other)98%Glass2%Brown Fibrous Homogeneous University Ford Showroom Building - White Tile 12x12 Hallway S-6B-Floor Tile 291603738-0013 None DetectedNon-fibrous (Other)100%Cellulose<1%White Non-Fibrous Homogeneous University Ford Showroom Building - White Tile 12x12 Showroom S-6B-Mastic 291603738-0013A None DetectedNon-fibrous (Other)98%Cellulose2%Brown/Tan Fibrous Homogeneous University Ford Showroom Building - White Tile 12x12 Showroom S-7A-Floor Tile 291603738-0014 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous University Ford Showroom Building - Gray Tile 12x12 Hallway S-7A-Mastic 291603738-0014A None DetectedNon-fibrous (Other)98%Cellulose2%Brown Fibrous Homogeneous University Ford Showroom Building - Gray Tile 12x12 Hallway S-7B-Floor Tile 291603738-0015 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous University Ford Showroom Building - Gray Tile 12x12 Showroom S-7B-Mastic 291603738-0015A None DetectedNon-fibrous (Other)98%Cellulose2%Brown/Tan Fibrous Homogeneous University Ford Showroom Building - Gray Tile 12x12 Showroom S-8A-Floor Tile 291603738-0016 None DetectedNon-fibrous (Other)98%Cellulose2%Gray Fibrous Homogeneous University Ford Showroom Building - Gray Tile 12x12 Lunch Room Initial Report From: 06/13/2016 10:14:44 Page 2 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type S-8A-Mastic 291603738-0016A None DetectedNon-fibrous (Other)98%Cellulose2%Brown Fibrous Homogeneous University Ford Showroom Building - Gray Tile 12x12 Lunch Room S-8B-Floor Tile 291603738-0017 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous University Ford Showroom Building - Gray Tile 12x12 Lunch Room S-8B-Mastic 291603738-0017A None DetectedNon-fibrous (Other)98%Cellulose2%Brown/Tan Fibrous Homogeneous University Ford Showroom Building - Gray Tile 12x12 Lunch Room S-9A 291603738-0018 None DetectedNon-fibrous (Other)86%Cellulose Glass Wollastonite 12% 2% <1% White Fibrous Homogeneous University Ford Showroom Building - Lunch Room DW/JC This is a composite result of drywall, and joint compound. S-9B 291603738-0019 None DetectedNon-fibrous (Other)85%Cellulose Glass Wollastonite 12% 3% <1% White Fibrous Homogeneous University Ford Showroom Building - Hall DW/JC This is a composite result of drywall, and joint compound. S-9C 291603738-0020 None DetectedNon-fibrous (Other)77%Cellulose Glass Wollastonite 15% 8% <1% Gray/White Fibrous Homogeneous University Ford Showroom Building - Showroom DW/JC This is a composite result of drywall, and joint compound. S-10A 291603738-0021 None DetectedNon-fibrous (Other)5%Cellulose Min. Wool Glass 5% 60% 30% Brown/White Fibrous Homogeneous University Ford Showroom Building - Smooth CT 2x2 Hall S-10B 291603738-0022 None DetectedNon-fibrous (Other)5%Cellulose Min. Wool Glass 5% 60% 30% Brown/White Fibrous Homogeneous University Ford Showroom Building - Smooth CT 2x2 Hall S-10C 291603738-0023 None DetectedNon-fibrous (Other)15%Cellulose Min. Wool Glass 5% 60% 20% Tan/White Fibrous Homogeneous University Ford Showroom Building - Smooth CT 2x2 Hall S-11A 291603738-0024 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous University Ford Showroom Building - Smooth/Small Holes CT 2x4 Hall S-11B 291603738-0025 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous University Ford Showroom Building - Smooth/Small Holes CT 2x4 Hall S-11C 291603738-0026 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Gray/White Fibrous Homogeneous University Ford Showroom Building - Smooth/Small Holes CT 2x4 Hall S-12A 291603738-0027 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous University Ford Showroom Building - Large Hole CT 2x2 Hall S-12B 291603738-0028 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous University Ford Showroom Building - Large Hole CT 2x2 Hall S-12C 291603738-0029 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% White/Beige Fibrous Homogeneous University Ford Showroom Building - Large Hole CT 2x2 Hall Initial Report From: 06/13/2016 10:14:44 Page 3 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type S-13A 291603738-0030 None DetectedNon-fibrous (Other)90%Glass10%Gray/White Fibrous Homogeneous University Ford Showroom Building - Surfacing on Addition S-13B 291603738-0031 None DetectedNon-fibrous (Other)100%Cellulose<1%White Non-Fibrous Homogeneous University Ford Showroom Building - Surfacing Showroom S-13C 291603738-0032 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous University Ford Showroom Building - Surfacing Showroom S-14A 291603738-0033 None DetectedNon-fibrous (Other)97%Glass3%Gray Fibrous Homogeneous University Ford Showroom Building - Grey Caulking Window S-14B 291603738-0034 None DetectedNon-fibrous (Other)97%Cellulose Glass <1% 3% Gray Fibrous Homogeneous University Ford Showroom Building - Grey Caulking Window S-15A 291603738-0035 None DetectedNon-fibrous (Other)100%Gray/White Non-Fibrous Homogeneous University Ford Showroom Building - White Caulking S-15B 291603738-0036 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous University Ford Showroom Building - White Caulking S-16A 291603738-0037 None DetectedNon-fibrous (Other)98%Cellulose2%Tan Fibrous Homogeneous University Ford Showroom Building - Carpet Mastic S-16B 291603738-0038 None DetectedNon-fibrous (Other)95%Cellulose Synthetic 2% 3% Tan Fibrous Homogeneous University Ford Showroom Building - Carpet Mastic S-17A 291603738-0039 None DetectedNon-fibrous (Other)98%Cellulose2%Tan/White/Black Fibrous Homogeneous University Ford Showroom Building - Baseboard Mastic S-17B 291603738-0040 None DetectedNon-fibrous (Other)95%Cellulose5%Tan Fibrous Homogeneous University Ford Showroom Building - Baseboard Mastic S-18A-Floor Tile 291603738-0041 None DetectedNon-fibrous (Other)100%Tan Non-Fibrous Homogeneous University Ford Showroom Building - 12x12 FT Black w/ Mastic S-18A-Mastic 291603738-0041A None DetectedNon-fibrous (Other)95%Cellulose Synthetic 3% 2% Black Fibrous Homogeneous University Ford Showroom Building - 12x12 FT Black w/ Mastic S-18B-Floor Tile 291603738-0042 None DetectedNon-fibrous (Other)100%Brown/Tan Non-Fibrous Homogeneous University Ford Showroom Building - 12x12 FT Black w/ Mastic S-18B-Mastic 291603738-0042A None DetectedNon-fibrous (Other)95%Cellulose Synthetic 2% 3% Brown/Black Fibrous Homogeneous University Ford Showroom Building - 12x12 FT Black w/ Mastic S-19A 291603738-0043 None DetectedNon-fibrous (Other)10%Cellulose Min. Wool Glass 10% 45% 35% Brown/White Fibrous Homogeneous University Ford Showroom Building - Smooth CT Show Addition Initial Report From: 06/13/2016 10:14:44 Page 4 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type S-19B 291603738-0044 None DetectedNon-fibrous (Other)10%Cellulose Min. Wool Glass 10% 45% 35% Brown/White Fibrous Homogeneous University Ford Showroom Building - Smooth CT Show Addition S-19C 291603738-0045 None DetectedNon-fibrous (Other)25%Cellulose Min. Wool Glass 5% 60% 10% Tan/White Fibrous Homogeneous University Ford Showroom Building - Smooth CT Show Addition SR-1A 291603738-0046 None DetectedNon-fibrous (Other)15%Cellulose85%Brown Fibrous Homogeneous Showroom Bldg Roof - Roofing Felts SR-1B 291603738-0047 None DetectedNon-fibrous (Other)15%Cellulose85%Brown Fibrous Homogeneous Showroom Bldg Roof - Roofing Felts SR-1C 291603738-0048 None DetectedNon-fibrous (Other)20%Cellulose80%Brown Fibrous Homogeneous Showroom Bldg Roof - Roofing Felts SR-2A 291603738-0049 None DetectedNon-fibrous (Other)70%Cellulose30%Black Fibrous Homogeneous Showroom Bldg Roof - Tar/Tar Paper SR-2B 291603738-0050 None DetectedNon-fibrous (Other)70%Cellulose30%Black Fibrous Homogeneous Showroom Bldg Roof - Tar/Tar Paper SR-4A 291603738-0051 None DetectedNon-fibrous (Other)80%Glass20%Black Fibrous Homogeneous Showroom Bldg Roof - Shingles Roof SR-4B 291603738-0052 None DetectedNon-fibrous (Other)75%Cellulose Glass 5% 20% Black Fibrous Homogeneous Showroom Bldg Roof - Shingles Roof SR-5A 291603738-0053 None DetectedNon-fibrous (Other)75%Glass25%Black Fibrous Homogeneous Showroom Bldg Roof - Tar Paper Under Shingle SR-5B 291603738-0054 None DetectedNon-fibrous (Other)85%Glass15%Various/Black Fibrous Homogeneous Showroom Bldg Roof - Tar Paper Under Shingle SR-6A 291603738-0055 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous Showroom Bldg Roof - Sealant by Addition Light Grey SR-6B 291603738-0056 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous Showroom Bldg Roof - Sealant by Addition Light Grey SR-7A 291603738-0057 None DetectedNon-fibrous (Other)100%Synthetic<1%Black Non-Fibrous Homogeneous University Ford Showroom Roof - Sealant on AC (NW) SR-7B 291603738-0058 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous University Ford Showroom Roof - Sealant on AC (NW) SR-8A 291603738-0059 None DetectedNon-fibrous (Other)100%Cellulose<1%Gray Non-Fibrous Homogeneous University Ford Showroom Roof - Sealant on AC (NE) Dark Gray SR-8B 291603738-0060 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous University Ford Showroom Roof - Sealant on AC (NE) Dark Gray Initial Report From: 06/13/2016 10:14:44 Page 5 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type SR-9A 291603738-0061 None DetectedNon-fibrous (Other)100%Gray/White/Blue Non-Fibrous Homogeneous University Ford Showroom Roof - Surfacing on Parapit Wall Inseparable paint / coating layer included in analysis SR-9B 291603738-0062 None DetectedNon-fibrous (Other)98%Glass2%Gray/White Fibrous Homogeneous University Ford Showroom Roof - Surfacing on Parapit Wall SR-9C 291603738-0063 None DetectedNon-fibrous (Other)98%Glass2%Gray Fibrous Homogeneous University Ford Showroom Roof - Surfacing on Parapit Wall SR-10A 291603738-0064 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous University Ford Showroom Roof - Sealant on Parapit Wall SR-10B 291603738-0065 None DetectedNon-fibrous (Other)100%Gray/Black Non-Fibrous Homogeneous University Ford Showroom Roof - Sealant on Parapit Wall SR-11A 291603738-0066 None DetectedNon-fibrous (Other)98%Cellulose2%Black Fibrous Homogeneous University Ford Showroom Roof - Sealant Around Patch Work SR-11B 291603738-0067 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous University Ford Showroom Roof - Sealant Around Patch Work SR-12A 291603738-0068 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous Showroom Addition - White Sealant Near Additoin SR-12B 291603738-0069 None DetectedNon-fibrous (Other)100%White/Black Non-Fibrous Homogeneous Showroom Addition - White Sealant Near Additoin SA-1A-Floor Tile 291603738-0070 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous Showroom Addition - Black FT SA-1A-Mastic 291603738-0070A None DetectedNon-fibrous (Other)95%Cellulose Glass 3% 2% Tan Fibrous Homogeneous Showroom Addition - Black FT SA-1B-Floor Tile 291603738-0071 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous Showroom Addition - Black FT SA-1B-Mastic 291603738-0071A None DetectedNon-fibrous (Other)98%Cellulose2%Brown Fibrous Homogeneous Showroom Addition - Black FT SA-2A-Floor Tile 291603738-0072 None DetectedNon-fibrous (Other)100%Cellulose<1%White Non-Fibrous Homogeneous Showroom Addition - White FT SA-2A-Mastic 291603738-0072A None DetectedNon-fibrous (Other)98%Cellulose2%Yellow Fibrous Homogeneous Showroom Addition - White FT SA-2B-Floor Tile 291603738-0073 None DetectedNon-fibrous (Other)100%Beige Non-Fibrous Homogeneous Showroom Addition - White FT Initial Report From: 06/13/2016 10:14:44 Page 6 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type SA-2B-Mastic 291603738-0073A None DetectedNon-fibrous (Other)98%Cellulose2%Yellow Fibrous Homogeneous Showroom Addition - White FT SA-3A-Floor Tile 291603738-0074 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous Showroom Addition - Gray FT SA-3A-Mastic 291603738-0074A None DetectedNon-fibrous (Other)98%Cellulose2%Yellow Fibrous Homogeneous Showroom Addition - Gray FT SA-3B-Floor Tile 291603738-0075 None DetectedNon-fibrous (Other)100%Beige Non-Fibrous Homogeneous Showroom Addition - Gray FT SA-3B-Mastic 291603738-0075A None DetectedNon-fibrous (Other)98%Cellulose2%Yellow Fibrous Homogeneous Showroom Addition - Gray FT SA-4A 291603738-0076 None DetectedNon-fibrous (Other)85%Cellulose Glass Wollastonite 12% 3% <1% White Fibrous Homogeneous Showroom Addition - DW/JC SA-4B 291603738-0077 None DetectedNon-fibrous (Other)85%Cellulose Glass Wollastonite 12% 3% <1% White Fibrous Homogeneous Showroom Addition - DW/JC SA-4C 291603738-0078 None DetectedNon-fibrous (Other)75%Cellulose Glass 20% 5% Brown/White Fibrous Homogeneous Showroom Addition - DW/JC AR-1A 291603738-0079 None DetectedNon-fibrous (Other)98%Glass2%White Non-Fibrous Homogeneous Showroom Addition Roof - Surfacing on Side of Roof AR-1B 291603738-0080 None DetectedNon-fibrous (Other)98%Glass2%Gray/White Fibrous Homogeneous Showroom Addition Roof - Surfacing on Side of Roof AR-1C 291603738-0081 None DetectedNon-fibrous (Other)98%Glass2%Gray Fibrous Homogeneous Showroom Addition Roof - Surfacing on Side of Roof AR-2A 291603738-0082 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous Showroom Addition Roof - Sealant at Corner of bldg AR-2B 291603738-0083 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous Showroom Addition Roof - Sealant at Corner of bldg AR-3A 291603738-0084 None DetectedNon-fibrous (Other)15%Cellulose85%Brown/Black Fibrous Homogeneous Showroom Addition Roof - Roofing Felts AR-3B 291603738-0085 None DetectedNon-fibrous (Other)15%Cellulose85%Brown Fibrous Homogeneous Showroom Addition Roof - Roofing Felts AR-3C 291603738-0086 None DetectedNon-fibrous (Other)20%Cellulose80%Brown Fibrous Homogeneous Showroom Addition Roof - Roofing Felts AR-4A 291603738-0087 None DetectedNon-fibrous (Other)80%Cellulose20%Black Fibrous Homogeneous Showroom Addition Roof - Tar/Tar Paper AR-4B 291603738-0088 None DetectedNon-fibrous (Other)80%Cellulose20%Black Fibrous Homogeneous Showroom Addition Roof - Tar/Tar Paper AR-5A 291603738-0089 None DetectedPerlite Non-fibrous (Other) 20% 5% Cellulose75%Brown Fibrous Homogeneous Showroom Addition Roof - Roofing Insulation Initial Report From: 06/13/2016 10:14:44 Page 7 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type AR-5B 291603738-0090 None DetectedPerlite Non-fibrous (Other) 20% 5% Cellulose75%Brown Fibrous Homogeneous Showroom Addition Roof - Roofing Insulation AR-5C 291603738-0091 None DetectedPerlite Non-fibrous (Other) 30% 10% Cellulose60%Brown Fibrous Homogeneous Showroom Addition Roof - Roofing Insulation R-1A 291603738-0092 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous Maintenance and Repair Bldg - Black FT 12x12 Insufficient amount of mastic for analysis. R-1B-Floor Tile 291603738-0093 None DetectedNon-fibrous (Other)100%Black Non-Fibrous Homogeneous Maintenance and Repair Bldg - Black FT 12x12 R-1B-Mastic 291603738-0093A None DetectedNon-fibrous (Other)93%Cellulose Glass 2% 5% Red Fibrous Homogeneous Maintenance and Repair Bldg - Black FT 12x12 R-2A 291603738-0094 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous Maintenance and Repair Bldg - Grey FT 12x12 Insufficient amount of mastic for analysis. R-2B-Floor Tile 291603738-0095 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous Maintenance and Repair Bldg - Grey FT 12x12 R-2B-Mastic 291603738-0095A None DetectedNon-fibrous (Other)98%Cellulose2%Yellow Fibrous Homogeneous Maintenance and Repair Bldg - Grey FT 12x12 R-3A 291603738-0096 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous Maintenance and Repair Bldg - White FT 12x12 Insufficient amount of mastic for analysis. R-3B-Floor Tile 291603738-0097 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous Maintenance and Repair Bldg - White FT 12x12 R-3B-Mastic 291603738-0097A <1% ChrysotileNon-fibrous (Other)98%Cellulose2%Orange Fibrous Homogeneous Maintenance and Repair Bldg - White FT 12x12 R-4A 291603738-0098 25% ChrysotileNon-fibrous (Other)45%Cellulose30%Gray/White Fibrous Homogeneous Maintenance and Repair Bldg - HVAC Duct Upstairs Storage R-4B 291603738-0099 Positive Stop (Not Analyzed)Maintenance and Repair Bldg - HVAC Duct Upstairs Storage R-4C 291603738-0100 Positive Stop (Not Analyzed)Maintenance and Repair Bldg - HVAC Duct Upstairs Storage R-5A 291603738-0101 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous Maintenance and Repair Bldg - 2x4 CT Pits Dips R-5B 291603738-0102 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous Maintenance and Repair Bldg - 2x4 CT Pits Dips R-5C 291603738-0103 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 40% 30% Gray/White Fibrous Homogeneous Maintenance and Repair Bldg - 2x4 CT Pits Dips R-6A 291603738-0104 None DetectedNon-fibrous (Other)80%Cellulose Glass 15% 5% White Fibrous Homogeneous Maintenance and Repair Bldg - DW/JC Initial Report From: 06/13/2016 10:14:44 Page 8 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type This is a composite result of drywall, and joint compound. R-6B 291603738-0105 None DetectedNon-fibrous (Other)80%Cellulose Glass 15% 5% White Fibrous Homogeneous Maintenance and Repair Bldg - DW/JC This is a composite result of drywall, and joint compound. R-6C 291603738-0106 None DetectedNon-fibrous (Other)75%Cellulose Glass 20% 5% Tan/White Fibrous Homogeneous Maintenance and Repair Bldg - DW/JC This is a composite result of drywall, and joint compound. RR-1A 291603738-0107 None DetectedNon-fibrous (Other)95%Synthetic5%Gray/White Fibrous Homogeneous Maintenance and Repair Bldg Roof - Roofing Sealant/Paint RR-1B 291603738-0108 None DetectedNon-fibrous (Other)97%Cellulose3%Gray/White Fibrous Homogeneous Maintenance and Repair Bldg Roof - Roofing Sealant/Paint RR-2A 291603738-0109 None DetectedNon-fibrous (Other)98%Cellulose2%Gray/White Fibrous Homogeneous Maintenance and Repair Bldg Roof - Penetration Sealant RR-2B 291603738-0110 None DetectedNon-fibrous (Other)100%White/Black Non-Fibrous Homogeneous Maintenance and Repair Bldg Roof - Penetration Sealant RR-3A 291603738-0111 None DetectedNon-fibrous (Other)98%Cellulose Glass 2% <1% Gray/White Fibrous Homogeneous Maintenance and Repair Bldg Roof - White Sealant RR-3B 291603738-0112 None DetectedNon-fibrous (Other)96%Cellulose Glass 2% 2% Tan/Black Fibrous Homogeneous Maintenance and Repair Bldg Roof - White Sealant RR-4A 291603738-0113 None DetectedNon-fibrous (Other)80%Cellulose20%Black Fibrous Homogeneous Maintenance and Repair Bldg Roof - Black Tar Under RR-3 RR-4B 291603738-0114 None DetectedNon-fibrous (Other)85%Cellulose15%Black Fibrous Homogeneous Maintenance and Repair Bldg Roof - Black Tar Under RR-3 BR-1A 291603738-0115 15% ChrysotileNon-fibrous (Other)85%Gray/White/Black Fibrous Homogeneous Auto Body Shop Roof - Penetration Sealant BR-1B 291603738-0116 Positive Stop (Not Analyzed)Auto Body Shop Roof - Penetration Sealant BR-2A 291603738-0117 5% ChrysotileNon-fibrous (Other)85%Cellulose10%Brown/White/Silver Fibrous Homogeneous Auto Body Shop Roof - Sealant (Brown) w/ Outer Layer BR-2B 291603738-0118 Positive Stop (Not Analyzed)Auto Body Shop Roof - Sealant (Brown) w/ Outer Layer BR-3A 291603738-0119 None DetectedNon-fibrous (Other)60%Synthetic40%Gray/White Fibrous Homogeneous Auto Body Shop Roof - Surface Fabric BR-3B 291603738-0120 None DetectedNon-fibrous (Other)80%Synthetic20%Gray Fibrous Homogeneous Auto Body Shop Roof - Surface Fabric S-22A 291603738-0121 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous University Ford Showroom Bldg - Addition Pitted CT S-22B 291603738-0122 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous University Ford Showroom Bldg - Addition Pitted CT Initial Report From: 06/13/2016 10:14:44 Page 9 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603738EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type S-22C 291603738-0123 None DetectedPerlite Non-fibrous (Other) 30% 10% Cellulose Min. Wool 40% 20% Tan/White Fibrous Homogeneous University Ford Showroom Bldg - Addition Pitted CT Analyst(s) Joshua Moorman (79) Kelly Gallisdorfer (25) Roxsee Stover (37) Essie Spencer, Laboratory Manager or Other Approved Signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296 Initial Report From: 06/13/2016 10:14:44 Page 10 of 10PLM - 1.69 Printed: 6/13/2016 10:14 AM OrderID: 291603738 Page 1 Of 6 ..... A-~-~-~"1.-IL_..._.,~-· -----~-~------,~SL ANALYTICAL, INC. ,.. Atlantic Shores Environmental Svcs .• Lid Order ID: 291603738 00 GATEWAY CENTRE 12m No samples: 120 Due: 06111 5:00 PM BLVD, SUITE 600 619/201617:0 PLM TAT: 48 Hour Bulk Fax: 91 D-371-6652 RRISVILLE, NC 27560 EM Wt . rlONE: (919) 465-3900 FAX: (919) 465-3950 EMSL-Bill to: l...'1'"5ame D Different If 8111 to is Different note instructions in Comments** Comcanv: A ~)~,,,tc Shor(.() (.;M' . .-,~..,,,k,,\ Oisb"') Street: )s'\ IS'",ti..,~ QJ. Third Parlv Bi/lino reauires written authorization from third oartv Citv: l.<-l.,,J I State/Province: /J (, Zic/Postal Code: I Countrv: Reoort To INamel: lhtrv\ ;t,J.nJ., Telechone #: Fax#: I Purchase Order: Proiect Name/Number: )l '1 J, A Please Provide Results: D Fax D Email U.S. State Samples Taken: ~rr CT Samcles: D CommercialrTaxable D ResidentialrTax Exemct Turnaround Time (TAT) Options* -Please Check D 3 Hour I D 6 Hour I D 24 Hour I , x4a Hour I D 72 Hour I D 96 Hour I D 1 Week I D 2 Week *For TEM Air3 hr through 6 hr, please call ahead to schedule ... ,here is a premium charge for3 Hour TEM AHERA or EPA Level II TAT. You will be asked to sign an authorization form for this service. Analvsis comofeted in accordance with EMSL's Terms and Conditions located in the Anafvticaf Price Guide. / PLM • Bulk (reporting limit} TEM -Bulk G"PlM EPA 600/R-93/116 (<1%) .......... ··········---··-··-····-·-................ 0 TEM EPA NOB -EPA 600/R-93/116 Section 2.5.5.1 ......... . _g_1:'_1J,,1_E!'llf'l()E!(-<1'Y~L__ .. ...... ... . ...... .. ......... ........ . ... _D NY ELAPMethod198.4(TEM) ... ... .. ........... ...... ...... .. ..................... . Point Count __ D_400 (<0.25%)_0_1000 (<0.1%)___ ......... _D_Chatfield_Protocol_(semi-quantitative) _____ .. ____ ............. . _Point Count w/Gravimetric D 400_(<0.25%)_0 1000 (<0.1%) _D TEM_% by_Mass_-_EPA 600/R-93/1_16_Section 2.5.5.2 __ D NIOSH __ 9002 (<1_%L................. . ......... .... _ ...... D TEMQualitative via_Filtration Prep Technique ...... _ D NY ELAP Method 198.1 (friable in NY) D TEM Qualitative via Drop Mount Prep Technique _ 0 NY ELAP Method 198.6. NOB (non-friable-NY)....... ....... ... ......... Other O OSHA ID-191 Modified ----·-············-·····--··-····-··-·-·····--····--····· .. ·······························--·-· ··-·-···· D Standard Addition Method D D Check For Positive Stop -Clearly ldentifv Homoaenous Group I Date Sampled: Samplers Name: t/J.~I .)w.,'."'-L £, ', -;., / Ji2 v.rd, I Samplers Signature: . , . Sample# HA# Samele Location Material Description S-1 t3 l v ,,· /.e. 5-!iA Client Sample# (s): ;::i-IA . ,,rs e --~ s Total# of Samples: 12..o Relinquished (Client): /. Date: I, /tJcl /J 1., Time: JI] DS- Received (Lab): A.A...---oate: 1" le, I Iv Time: S' Or-- Comments/Special Instructions: ( -l I . Controlled Document-Asbestos COC -R2 -41912013 Page 1 of ___fu_ pages OrderID: 291603738 Page 2 Of 6 Asbestos Bulk Building Material Chain of Custody EMSL ANALYTICAL, INC. 2500 GATEWAY CENTRE BLVD, SUITE 600 WILLE, NC 27560 EMSL~ LA!lORATO Atlantic Shores Environmental Svcs., Ltd 1272A 6/9/2016 17:0 PLM TAT: 48 Hour Bulk Order ID: 291603738 No Samples: 120 Due: 06/11 5:00 PM Fax: 910-371-6652 ~E: 919-465-3900 l\X. § I §-455-3§55 Additiona, jJages OT Crlf:t L,/lt/111 UI \.JU.:>tvuy a11;; VIIJ.Y ,,....,...,,..,..,,.,o.J,J .. "~----. -----Jn Sample# HA# Sam pie Location Material Descriotion ;i --5A \.)"':v,r;; :kj fo,J ;';'hov-> ttv= 1:?"11r"" fj),,,l ]c., 'I--·t-<. r@ c.1,s,} k,.r I <..) ll h 5-513 C' -, ..J ~ ~ s-loA wk:t! ./-.'/.{. //..,(/) ]-\ .-.1 t vJ"""I ( s-(u l3 \A.l l: \;. \_.' l-i IJ.t)L c5!.,wl'c0,,., 25-'/ A l., r," )-,'/'{. iJ.~ /). 1-1,,11 "'''Y ' ' -3. 'If 1._,.,..v /..,'k Ux/L 31..a"-'.,,. ,__ 5 -6"A '/_,,.,, )-. h 1µ/L .£ n t /,._ tr""',_ 6-_158 \ ._' . 7; S-9A l v" l !,, rov,.,. ))\;-' /., ( .5-91-3 l-1,,,, ~"'-' / ~ (. 5-9t. 5 h11,-,Jv J ·"-))Vu/:,(, s-1 oA Svi,,wiLc CT J,xQ_ /~,a.ll 5-to G "' {; <;;· Io l " 1, ' ·.' 3'-II A 5...,..,1,1./~.,.,. lot~ GT 2.,<L ,~ 5.11 0 \<.-"'' S-l·IC lL ;!; ,')-)LA .l.J-c,_, l.o lt. c, l,< k. 1-t.,, l l S-11 y ,, Jl ~ ..... ,5-ltl < LL .t I 5-)3A 5,1f..c:.,_, """ t,.,U_.·P-~ :5-IJ 13 ;)vJf..,,.<\ ,Jt...av-> n,o,,.,_ < ' / .. 7-le) '--~ . ,, •comments/Special Instructions: Page _1_ of __k_ pages controlled Document -Asbestos COC-R2-41912013 OrderID: 291603738 Page 3 Of 6 ...A.. Asbestc:,.s Bulk Building Material ~ OrderlD: 291603738 EMSL ANALYTICAL, INC . '~y CENTRE BLVD, SUITE 600 /ILLE, NC 27560 , Atlantic Shores Environmental Svcs., Ud No samples: 120 1272A Due: 06/11 5:00 PM ~ TAT: 48 Hour 371-6652 I.ABORATORV 6191201617:0 Fax: 910-______ Bulk PLM _;: 919-465-3900 FAX. !3 I §-4C>a-3!:!0a Additiona, , a>J"'" u1 me c;nain of Custody are only necessary if needed for additional sample information Sample# HA# Samele Location Material Descriotion S-1'-IA LJ Y1 ) ii !<) : !"I F~rJ :J "'""""°"" 6.,: I J.',0 1 l nN.,1 (c,i u l I:.'~· .{!J; v..do vV 5-1 J.J '.8 ,J l .J 'z _, S-JS'A ~ \,...l l,c_ {,,.~Jtc!,, 5-15 JJ L\ -.., 1t S-Ji A (r,.r\l l-1'1"'5 <-c s-n .ls \, 1; 5 -1'],l\ g., t t.1:, o«r J. )1..SL'r._ 5-l'l /J ,, '1 S-17 A J)x!J. [.T J/n d-, ,1,v/ ,r,w;s /_1-(._ 5-17 t3' \\ // 5-/q,/.l 5-noo t,k. c, ohoiP c..dd ,'/."-. 6-)q L? \C ,:./ s-,q c. \ I VI. ,, jg· lA S hw· t""""' !JIJ._ 'f2.oof fo.A-<,,,, J_,_ I \.;i v '-J ~f -I !3 IC /, Sf<!· IL \\ ,, 5fL-~A lw / /,,r ;,~pv-. l.51e-JG \\ I· ISQ-1-\ A :51,,1.._~,,-{Rovf) 5(l-'-11? ,, v t, ..... 5(2.-s---A f,,.r ,-.,,.,v-,.,,,J,,... st...:~,'-<-- 1, ' ' v St!.-SB ,., $112-loA , s~,,.J..., r by ,.d,!.;"\,.., (J.0~ ,.__ ~"Y ) -\ l ' ..J It.· \.sHJ ~ . ' •comments/Special Instructions: Page _5__ of __l_ pages Controlled Documenl -Asbestos coc -R2 -4/9/2013 OrderID: 291603738 Page 4 Of 6 Asbestos Bulk Building Material EMSLANALn1cAL, INc. 2500 GATEWAY CENTRE BLVD, ~---c:-------~Cbain of Custod}! su1TE 500 !antic Shores Environmental Svcs., Ud Order ID: 291-603-73-8---------\LE, NC 27560 • 1272A EMSL ANAi No Samples: 120 ~·•=m~·'" 6/9/201617:0 TAT: 48 Hour Due: 06/115:00 PM 919-465-3900 ------PLM Bulk Fax: 910-371-6652 § I §-465-3§55 Additional Pages of the Chain ot Cusrooy are omy ner.;e:s:sa1y" """u"u ,u, guurnvuv, vu .. ,,-,_····-····-··-_ Sample# HA# Sample Location Material Descrioti on S"f-1A \Jn '.o~, ~ ~ J SJ..011u'• .:,,--lfuol 3,t,J ... c //,,, ,Al [/\J'v-J~ 51!-., ·1'.3 \ '-,.., 3i-1A Se",,...,. i-o...... AG [AJb-') J,4. yty 5"¥?.-713 1, I, 5,2-q /.l l~v,4,.L •A -'"'""' L w-1 l ~ , sn-"113 k "' Si-C/L ''-..,,, SY.?-1o A Si~/ ,a ~ O"\ fl> Al' 1<J>' l w,-,11 SYl-1of3 "' ' ., -J'/2.-Ii A 5-lAI,-.,. ~ A,M, ~J r, ,.h l. k),,,-1:.. :312-1113 " I-, 511.-Jl A wh'.k s,"1,.,J--}l\{,r t'-Jc!JLL 1512-n 13 \,,. \: '\. /1 fi'A -I A .5 /... 0 ..,. l'OtJ ....._ .,.) d : r."\. _ E'/1-dc F, SA -? 13 " t-, 5A-, .1.A (/'-l l.: k FT 5A; ,-13 ,-,, SA_:lA &,,-.,,, FT S'A-JfJ ' ,.. 1, J/1-l/.JI , .... l:,iN /;(__ 54-,i-! B ~ ,, 5 A -,i.j,1., IL It *Comments/Special Instructions: Page 2_ of ___k__ pages Controlled Documenl -Asbestos coc-R2 -41912013 OrderID: 291603738 Page 5 Of 6 ------------- • Asbestos Bulk Building Material EMSLANALYT1cAL, /Ne. 2500 GATEWAY CENTRE BLVD, ~------__ Chain_oJ_Cus_todv ________ ~ su1TE 500 Atlantic Shores Environmental Svcs., Ltd Order ID: 291603738 VILLE, NC 27560 EMSLAI ~ 1272A No Samples: 120 Due: 06/11 5.00 PM IE: 919-465-3900 6/9/2016 17:0 TAT: 48 Hour Bulk PLM Fax: 910.371-6652 .x. § I §-4fla-3§06 Additional Pages of the Chain ot custoay are only necessary IJ flf:lf:jUtJU /UI dUU/llUlfat ;;,a,11,.,,0 1/f/VllrnAuVn Sample# HA# Sample Location Material Description At<-I!.\ '3 ~ VW IV 0•"'-AJJ: J '"" Je,.../ '3v,4rc !1 0 "-s:ck t I 't-&r; ! ~ 1112-13 \ I. '7 A 12-I L VL ,,.., A12-lA 3 01...,. i-,,J ( () r,ef :J. j, ,d~- v AR· .l 8 ,, 1, A1Q-JA fop4'e, 4,_JJ.., ~' -'1 Ml-; B 4fl-] l ~ ,, flff2. l\J.l )f.r /T" 1 ~ .. p,r-. A i2-l\ i} '-'-'r f:i-5 A fooef.'., ,1"".S"IA i.ti:t-. All· S iJ ~ v < At'-5L " ,, ,i,. ~-JA ;'1~ '~J.....,Vnl<.. Ml J N ~-· lr bu/J, tJuJc Pr 1.L<U • v \ ' ., ~-l J3 Q-J,A &, "''( r:, J,:',,,J). ' R-JB ,~ ., V.-].A 1,,Vk f, 1L, I .L (2.-J]3 ,, ,, 12· >lA .... ,.. l-1 v A L. bud-utfk,·,s .s.. to-1",ut • v £. i;,3 .... ,, p -t.tL ,v ,, I' 'Comments/Special Instructions: Page __L of _k_ pages Controlled Do~ument-Asbastos CCC -R2 -41912013 OrderID: 291603738 Page 6 Of 6 • Asbestos Bulk Building Material ___ ~EMSLANALYT1cAL, INc. --\T8NAY CENTRE BLVD, ' A!!antic Shores Environmental Svcs., Ud Order ID: 291603738 SUITE 600 No Samples: 120 1272A Due: 06111 5:00 PM RRISVILLE, NC 27560 !e!, 6'912D1617:0 TAT: 4BHo~:lk Fax: 910-371-6652 'HONE: 919-465-3900 ----LAI: PLM FAX. § I S-4i'l5-3§51'.l Additional Pages of the Chain of Custody are only necessary if needed for additional sample information Sample# HA# Sample Location Material Description t-~A /I>(),.:" L., 111, "-), tP{l~I Bid~ ,2x~ er f~!.5 -4' l. v /Z-5 3 ,-., fl-5G, ,, 1 R-fu ,4 PW/TC (2-bij ,, ,, fZ-~l. 'IV ... It ,Ztz-JA ;11.:., k~."" J, l-1.p14 !,-),/,I, /col fl"'' </:,, (.,, m 1-J.-/Pt!\ J-- v v , "1Z.1! -I 13 \' /} gfl.-2/l ~"' 1-,.,. J:,,_,_ .;,,,,, I«-,'+- (2£-J.13 " ,, 12.f!-3 A wL.:k S-e,,i,,\4 J.- [}fl-.113 \c " /Zll · '-lA )51,., L iL -1,..r v~ .l.,--/2 R.-.J /W.-<.J J? ~/ \,'. ,, if1.-1A Auh, bodv Sk,,,, ~ p, .( "'-< th. J.,l.,_ s-l.,_ 1,...,-J-. ' ' BR.-V!3 ,, ,._, 5e-1.A-c;,RIP-I, C:!3 ........... \ ,,,..:!-(._ '" J..t-I"''-' ,,__ )> P. ' )._, I] ''-,,_ i,l-5-A Jvr4,. <<--{.-,,,b rJ L Be-313, ~, \,-. 'I ,., f;-;lA u..,: • .,,:l, [u.rJ .:Sk...,,,.~'"' !,.,1.1\ AdJ:Lm i.-)h.t r-, 15-}t 1> ' . 5-2 l c_ ll/ •comments/Special Instructions: Page~ of .Ja.__ pages Controlled Document -Asbestos COC -R2-41912013 EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603781EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Attention:Phone:Cheryl Moody (910) 371-5980 Fax:Atlantic Shores Environmental Svcs., Ltd (910) 371-6652 Received Date:154 Backhoe Road 06/10/2016 3:30 PM Analysis Date:Leland, NC 28451 06/10/2016 Collected Date: Project:1272 A Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type K-1A 291603781-0001 None DetectedNon-fibrous (Other)100%Gray/White Non-Fibrous Homogeneous Kia Building - Exterior Surfacing K-1B 291603781-0002 None DetectedNon-fibrous (Other)100%Gray/White Non-Fibrous Homogeneous Kia Building - Exterior Surfacing K-1C 291603781-0003 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous Kia Building - Exterior Surfacing K-2A 291603781-0004 None DetectedNon-fibrous (Other)90%Cellulose10%Gray Fibrous Homogeneous Kia Building - Exterior Panneling K-2B 291603781-0005 None DetectedNon-fibrous (Other)92%Cellulose8%Gray Fibrous Homogeneous Kia Building - Exterior Panneling K-2C 291603781-0006 None DetectedNon-fibrous (Other)85%Cellulose15%Gray Fibrous Homogeneous Kia Building - Exterior Panneling K-3A 291603781-0007 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous Kia Building - Window (exterior) Caulking K-3B 291603781-0008 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous Kia Building - Window (exterior) Caulking K-4A-Floor Tile 291603781-0009 None DetectedNon-fibrous (Other)100%Gray/Blue Non-Fibrous Homogeneous Kia Building - Window (exterior) Caulking K-4A-Mastic 291603781-0009A None DetectedNon-fibrous (Other)95%Cellulose Synthetic 3% 2% Tan Fibrous Homogeneous Kia Building - Window (exterior) Caulking K-4B 291603781-0010 None DetectedNon-fibrous (Other)100%Cellulose<1%Gray/Blue Non-Fibrous Homogeneous Kia Building - 12x12 Light Blue FT Insufficient amount of mastic for analysis. K-5A 291603781-0011 None DetectedNon-fibrous (Other)100%Tan/White Non-Fibrous Homogeneous Kia Building - 12x12 Light Blue FT K-5B 291603781-0012 None DetectedNon-fibrous (Other)93%Cellulose Synthetic 5% 2% Tan/White Fibrous Homogeneous Kia Building - 12x12 Light Blue FT K-5C 291603781-0013 None DetectedNon-fibrous (Other)95%Cellulose Synthetic 3% 2% Gray/Tan Fibrous Homogeneous Kia Building - Backboard Mastic (original) K-6A 291603781-0014 None DetectedNon-fibrous (Other)77%Cellulose Glass 15% 8% Gray/White Fibrous Homogeneous Kia Building - Backboard Mastic (original) This is a composite result of drywall and jt. compound Initial Report From: 06/13/2016 13:26:41 Page 1 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603781EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type K-6B 291603781-0015 None DetectedNon-fibrous (Other)82%Cellulose Glass Wollastonite 10% 8% <1% Gray/White Fibrous Homogeneous Kia Building - Backboard Mastic (add on) This is a composite result of drywall and jt. compound K-6C 291603781-0016 None DetectedNon-fibrous (Other)80%Cellulose Glass 15% 5% White Fibrous Homogeneous Kia Building - DW/JC original This is a composite result of drywall, and jt. compound. K-7A 291603781-0017 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 30% 40% Gray/White Fibrous Homogeneous Kia Building - DW/JC original K-7B 291603781-0018 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 30% 40% Gray/White Fibrous Homogeneous Kia Building - DW/JC original K-7C 291603781-0019 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous Kia Building - 2x2 Powder CT K-8A 291603781-0020 None DetectedNon-fibrous (Other)85%Cellulose Glass Wollastonite 10% 5% <1% Gray/White Fibrous Homogeneous Kia Building - 2x2 Powder CT This is a composite result of drywall and jt. compound K-8B 291603781-0021 None DetectedNon-fibrous (Other)78%Cellulose Glass Wollastonite 15% 5% 2% Gray/White Fibrous Homogeneous Kia Building - 2x2 Powder CT This is a composite result of drywall and jt. compound K-8C 291603781-0022 None DetectedNon-fibrous (Other)80%Cellulose Glass Wollastonite 15% 5% <1% Brown/White Fibrous Homogeneous Kia Building - DW/JC Addition This is a composite result of drywall, and joint compound. K-9A 291603781-0023 None DetectedNon-fibrous (Other)98%Cellulose2%White Fibrous Homogeneous Kia Building - DW/JC Addition K-9B 291603781-0024 None DetectedNon-fibrous (Other)98%Cellulose2%White Fibrous Homogeneous Kia Building - DW/JC Addition S-20A 291603781-0025 None DetectedNon-fibrous (Other)10%Cellulose Min. Wool Glass 10% 65% 15% Gray/White Fibrous Homogeneous University Ford Showroom - HVAC Sealant S-20B 291603781-0026 None DetectedNon-fibrous (Other)5%Cellulose Min. Wool Glass 15% 65% 15% Gray/White Fibrous Homogeneous University Ford Showroom - HVAC Sealant S-20C 291603781-0027 None DetectedNon-fibrous (Other)15%Cellulose Min. Wool Glass 5% 60% 20% Brown/White Fibrous Homogeneous University Ford Showroom - HVAC Sealant S-21A 291603781-0028 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 30% 40% Gray/White Fibrous Homogeneous University Ford Showroom - Smooth CT Showroom S-21B 291603781-0029 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Gray/White Fibrous Homogeneous University Ford Showroom - Smooth CT Showroom S-21C 291603781-0030 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous University Ford Showroom - Smooth CT Showroom R-7A 291603781-0031 None DetectedPerlite Non-fibrous (Other) 5% 72% Cellulose Glass 15% 8% Tan/White Fibrous Homogeneous Maintenance & Repair Building - Pitted CT Showroom Initial Report From: 06/13/2016 13:26:41 Page 2 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603781EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type R-7B 291603781-0032 None DetectedPerlite Non-fibrous (Other) 5% 72% Cellulose Glass 15% 8% Tan/White Fibrous Homogeneous Maintenance & Repair Building - Pitted CT Showroom R-7C 291603781-0033 None DetectedNon-fibrous (Other)75%Cellulose Glass 20% 5% Brown/White Fibrous Homogeneous Maintenance & Repair Building - Pitted CT Showroom R-8A 291603781-0034 None DetectedNon-fibrous (Other)95%Cellulose5%Gray Fibrous Homogeneous Maintenance & Repair Building - CT 2x2 in drive thru R-8B 291603781-0035 None DetectedNon-fibrous (Other)98%Cellulose2%Gray Fibrous Homogeneous Maintenance & Repair Building - CT 2x2 in drive thru R-9A 291603781-0036 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 30% 40% Tan/White Fibrous Homogeneous Maintenance & Repair Building - CT 2x2 in drive thru R-9B 291603781-0037 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 30% 40% Tan/White Fibrous Homogeneous Maintenance & Repair Building - HVAC Sealant Upstairs R-9C 291603781-0038 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous Maintenance & Repair Building - HVAC Sealant Upstairs R-10A 291603781-0039 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 15% 55% Gray/Black Fibrous Homogeneous Maintenance & Repair Building - CT Bathroom 2x2 R-10B 291603781-0040 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 15% 55% Gray/Black Fibrous Homogeneous Maintenance & Repair Building - CT Lockeroom 2x2 R-10C 291603781-0041 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/Gray Fibrous Homogeneous Maintenance & Repair Building - CT Storage Room 2x4 R-11A-Floor Tile 291603781-0042 2% ChrysotileNon-fibrous (Other)96%Cellulose2%Gray/White Fibrous Homogeneous Maintenance & Repair Building - Locker FT w/ Mastic R-11A-Mastic 291603781-0042A 3% ChrysotileNon-fibrous (Other)97%Tan/Black Fibrous Homogeneous Maintenance & Repair Building - Locker FT w/ Mastic R-11B-Floor Tile 291603781-0043 Positive Stop (Not Analyzed)Maintenance & Repair Building - Locker FT w/ Mastic R-11B-Mastic 291603781-0043A Positive Stop (Not Analyzed)Maintenance & Repair Building - Locker FT w/ Mastic R-12A 291603781-0044 None DetectedNon-fibrous (Other)98%Cellulose2%Gray/White Fibrous Homogeneous Maintenance & Repair Building - North Shop Door Sealant R-12B 291603781-0045 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous Maintenance & Repair Building - North Shop Door Sealant R-13A 291603781-0046 8% ChrysotileNon-fibrous (Other)84%Cellulose Min. Wool 3% 5% Gray/Black Fibrous Homogeneous Maintenance & Repair Building - Sealant b/w Metal C-Block R-13B 291603781-0047 Positive Stop (Not Analyzed)Maintenance & Repair Building - Sealant b/w Metal C-Block R-14A 291603781-0048 3% ChrysotileNon-fibrous (Other)95%Cellulose2%Gray/White Fibrous Homogeneous Maintenance & Repair Building - C-Block Interior Corner Sealant Initial Report From: 06/13/2016 13:26:41 Page 3 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603781EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type R-14B 291603781-0049 Positive Stop (Not Analyzed)Maintenance & Repair Building - C-Block Interior Corner Sealant R-15A 291603781-0050 None DetectedNon-fibrous (Other)98%Cellulose2%White Fibrous Homogeneous Maintenance & Repair Building - Drive Thru Door Window Glazing R-15B 291603781-0051 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous Maintenance & Repair Building - Drive Thru Door Window Glazing R-16A 291603781-0052 None DetectedNon-fibrous (Other)100%Gray/White Non-Fibrous Homogeneous Maintenance & Repair Building - Caulking by R-15 R-16B 291603781-0053 None DetectedNon-fibrous (Other)100%Gray/White Non-Fibrous Homogeneous Maintenance & Repair Building - Caulking by R-15 B-1 291603781-0054 None DetectedNon-fibrous (Other)100%Gray/White Non-Fibrous Homogeneous Auto Body Shop Building - North Door Exterior Sealant B-2A 291603781-0055 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous Auto Body Shop Building - CT 2x4 E-Room B-2B 291603781-0056 None DetectedPerlite Non-fibrous (Other) 20% 10% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous Auto Body Shop Building - CT 2x4 E-Room B-2C 291603781-0057 None DetectedPerlite Non-fibrous (Other) 15% 15% Cellulose Min. Wool 30% 40% Brown/White Fibrous Homogeneous Auto Body Shop Building - CT 2x4 E-Room B-3A 291603781-0058 None DetectedNon-fibrous (Other)77%Cellulose Glass 15% 8% Gray/White Fibrous Homogeneous Auto Body Shop Building - DW/JC E- & Office This is a composite result of drywall and jt. compound B-3B 291603781-0059 None DetectedNon-fibrous (Other)80%Cellulose Glass Wollastonite 15% 5% <1% Gray/White Fibrous Homogeneous Auto Body Shop Building - DW/JC E- & Office This is a composite result of drywall and jt. compound B-3C 291603781-0060 None DetectedNon-fibrous (Other)75%Cellulose Glass Wollastonite 20% 5% <1% Brown/White Fibrous Homogeneous Auto Body Shop Building - DW/JC E- & Office This is a composite result of drywall, and jt. compound. B-4A 291603781-0061 None DetectedNon-fibrous (Other)98%Cellulose2%Gray/White Fibrous Homogeneous Auto Body Shop Building - Bathroom Sink Sealant B-4B 291603781-0062 None DetectedNon-fibrous (Other)98%Cellulose2%Gray/White Fibrous Homogeneous Auto Body Shop Building - Bathroom Sink Sealant B-5A-Floor Tile 291603781-0063 None DetectedNon-fibrous (Other)100%Gray Non-Fibrous Homogeneous Auto Body Shop Building - 12x12 FT w/ Mastic B-5A-Mastic 291603781-0063A None DetectedNon-fibrous (Other)98%Cellulose2%Tan Fibrous Homogeneous Auto Body Shop Building - 12x12 FT w/ Mastic B-5B-Floor Tile 291603781-0064 None DetectedNon-fibrous (Other)100%White Non-Fibrous Homogeneous Auto Body Shop Building - 12x12 FT w/ Mastic B-5B-Mastic 291603781-0064A None DetectedNon-fibrous (Other)98%Cellulose2%Tan Fibrous Homogeneous Auto Body Shop Building - 12x12 FT w/ Mastic Initial Report From: 06/13/2016 13:26:41 Page 4 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291603781EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type B-6A 291603781-0065 None DetectedNon-fibrous (Other)97%Cellulose3%Tan Fibrous Homogeneous Auto Body Shop Building - Backboard Mastic Office B-6B 291603781-0066 None DetectedNon-fibrous (Other)90%Cellulose10%Tan Fibrous Homogeneous Auto Body Shop Building - Backboard Mastic Office B-7A 291603781-0067 2% ChrysotileNon-fibrous (Other)94%Cellulose Wollastonite 2% 2% Gray Fibrous Homogeneous Auto Body Shop Building - South Door Interior Sealant B-7B 291603781-0068 Positive Stop (Not Analyzed)Auto Body Shop Building - South Door Interior Sealant Analyst(s) Joshua Moorman (24) Kelly Gallisdorfer (44) Essie Spencer, Laboratory Manager or Other Approved Signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296 Initial Report From: 06/13/2016 13:26:41 Page 5 of 5PLM - 1.69 Printed: 6/13/2016 1:26 PM EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600, Morrisville, NC 27560 Phone/Fax:(919) 465-3900 / (919) 465-3950 http://www.EMSL.com raleighlab@emsl.com 291603781 CustomerID:ATLS78 CustomerPO: ProjectID: EMSL Order: Attn:Cheryl Moody Atlantic Shores Environmental Svcs., Ltd 154 Backhoe Road Leland, NC 28451 Received: 06/10/16 3:30 PM 1272 A Fax:(910) 371-6652 Phone:(910) 371-5980 Project: 6/23/2016Analysis Date: Collected: SAMPLE ID APPEARANCE NON- ASBESTOS % NON-FIBROUS (%) Matrix Organic Acid ASBESTOS % TYPESDESCRIPTION NON- ASBESTOS % Fibrous Test Report: Polarized Light Microscopy (PLM) - Point Count Performed by EPA 600/R- 93/116 Method with Gravimetric Reduction and 400 Point Count R-11A-Floor Tile 291603781-0042 Gray/White 22.2Maintenance & Repair Building - Locker FT w/ Mastic Fibrous Homogeneous 36.3 Chrysotile3.2Non-fibrous (other)38.3 R-11A-Mastic 291603781-0042A Tan/Black 39.4Maintenance & Repair Building - Locker FT w/ Mastic Fibrous Homogeneous 52.3 Chrysotile0.5Non-fibrous (other)7.8 R-11B-Floor Tile 291603781-0043 Positive Stop (Not Analyzed) Maintenance & Repair Building - Locker FT w/ Mastic Positive Stop (Not Analyzed) R-11B-Mastic 291603781-0043A 43.4Maintenance & Repair Building - Locker FT w/ Mastic Fibrous Homogeneous 37.4 Chrysotile3.9Non-fibrous (other)15.3 R-14A 291603781-0048 Gray/White 14.1Maintenance & Repair Building - C-Block Interior Corner Sealant Fibrous Homogeneous 37.0 Chrysotile4.9Non-fibrous (other)44.0 R-14B 291603781-0049 Positive Stop (Not Analyzed) Maintenance & Repair Building - C-Block Interior Corner Sealant Positive Stop (Not Analyzed) Billy Barnes, Asbestos Lab Manager or other approved signatory Test Report PLMPCGrav-7.26.0 Printed: 6/23/2016 10:42:48 AM 1 Analyst(s) Disclaimers: Some samples may contain asbestos fibers present in dimensions below PLM resolution limits. The limit of detection as stated in the method is 0.25%. EMSL Analytical Inc. suggests that samples reported as <0.25% or none detected undergo additional analysis via TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical Inc.. This report must not be used to claim product endorsement by NVLAP or any agency of the United States Government. EMSL Analytical Inc. bears no responsibility for sample collection activities, analytical method limitations, or the accuracy of results whin requested to separate layer samples. EMSL Analytical Inc. liability is limited to the cost of sample analysis. The test results contained within this report meet the requirements of NELAC unless otherwise noted. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296 Joshua Moorman (4) Olivia Bradley (2) Initial report from 06/22/2016 16:43:59 EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600, Morrisville, NC 27560 Phone/Fax:(919) 465-3900 / (919) 465-3950 http://www.EMSL.com raleighlab@emsl.com 291603781 CustomerID:ATLS78 CustomerPO: ProjectID: EMSL Order: Attn:Cheryl Moody Atlantic Shores Environmental Svcs., Ltd 154 Backhoe Road Leland, NC 28451 Received: 06/10/16 3:30 PM 1272 A Fax:(910) 371-6652 Phone:(910) 371-5980 Project: 6/23/2016Analysis Date: Collected: SAMPLE ID APPEARANCE NON- ASBESTOS % NON-FIBROUS (%) Matrix Organic Acid ASBESTOS % TYPESDESCRIPTION NON- ASBESTOS % Fibrous Test Report: Polarized Light Microscopy (PLM) - Point Count Performed by EPA 600/R- 93/116 Method with Gravimetric Reduction and 400 Point Count B-7A 291603781-0067 Tan 32.3Auto Body Shop Building - South Door Interior Sealant Fibrous Homogeneous 29.9 Chrysotile0.9Non-fibrous (other)36.9 B-7B 291603781-0068 Tan 31.8Auto Body Shop Building - South Door Interior Sealant Fibrous Homogeneous 21.5 Chrysotile2.2Non-fibrous (other)44.5 Billy Barnes, Asbestos Lab Manager or other approved signatory Test Report PLMPCGrav-7.26.0 Printed: 6/23/2016 10:42:48 AM 2 Analyst(s) THIS IS THE LAST PAGE OF THE REPORT. Disclaimers: Some samples may contain asbestos fibers present in dimensions below PLM resolution limits. The limit of detection as stated in the method is 0.25%. EMSL Analytical Inc. suggests that samples reported as <0.25% or none detected undergo additional analysis via TEM. The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval by EMSL Analytical Inc.. This report must not be used to claim product endorsement by NVLAP or any agency of the United States Government. EMSL Analytical Inc. bears no responsibility for sample collection activities, analytical method limitations, or the accuracy of results whin requested to separate layer samples. EMSL Analytical Inc. liability is limited to the cost of sample analysis. The test results contained within this report meet the requirements of NELAC unless otherwise noted. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296 Joshua Moorman (4) Olivia Bradley (2) Initial report from 06/22/2016 16:43:59 OrderID: 291603781 Page 1 Of 4 • Asbestos Bulk Building Material Atlantic Shores Environmental Svcs .. Ltd Order ID: 291603781 1272 A No Samples: 68 EMSLANALv· 6/10/201615:30 TAT: 24Hour Due: 06/113.00PM EMSL ANALYTICAL lt.C "f:_\/'/AY CFNTR:= ID. SUITE 6JJ E. NC 2750C '-ABOll,•:ro ...... ~1100, PLM Bulk Fax: 910-371,6652 19 J 465-3900 --• ,v, ,d19) 465-3950 I I I , · ~ , I EMSL-Bill to: L.JSame D Different Company: ,'-I IH'\4' L 0 V\CJf~ (: viV ·~ 1.M......H'-<.l ~-\, l t) i If Bill to 1s Different note instructions in Comments·· Street: i c;· ~ CS:. L 'lk l ti J --------[ Third Partv 811/1nn renu1res written authonzation from third oartv City: (, ,·~-r ~le/Province: /\_;L I Zip/Postal Code: -~uritry:______ _ Renert To /Name\: c_lu,, \ /•ice•! _ Telephone#: I Email Address: (.Lici.,1'/ (£_• (,L~ . .:C.ls.1..,~1<~-(-j,tV (e,,V"L --Fax#:-::=="-----------r~~~r~------ Project Name/Number: /1 'l l ,6_ _ -------PlemP;:;;;;-;;~~ 0 Fax O Email ------ U.S. State Samoles Taken: JJ I -----CT Samoles: 0 Commercial/Taxable D Residential/Tax Exempt ,.--Turnaround Time IT A Tl Ootions• -Please Check D 3 Hour I D 6 Hour I ''"" 24 Hour I D 48 Hour I D 72 Hour I D 96 Hour I O 1 Week I D 2 Week "For TEM Air 3 hr through 6 hr, please call ahead to schedule. •rhere is a premium charge for 3 Hour TEM AHERA or EPA Level fl TAT You will be asked to sign an authorization form for this service. Ana/vsis comr.leted in accordance with EMSL 's Terms and Conditions located in the Ana/vfica! Price Guide. ,, PLM -Bulk (reporting limit) _ , TEM -Bulk _ @1fLM EPA 600/R-93/116 (<1%) 0 TEM EPA NOB-EPA 600/R-93/116 Section 2.5.51--- O PLM EPA NOB (<1 %) 0 NY ELAP Method 198-4 (TEM) Point Count D 400 (<0.25%) D 1000 (<0.1 %) D Chatfield Protocol (semi-quantitative) Point Count w/Gravimetric D 400 (<O 25%) D 1000 (<0.1 %) D TEM % by Mass -EPA 600/R-93/116 Section 2.5.5.2 D NIOSH 9002 (<1%) D TEM Qualitative via Filtration Prep Technique D NY ELAP Method 198.1 (friable ,n NY) 0 TEM Qualitative via Drop Mount Prep Tec_hnique ___ _ O NY ELAP Method 198.6 NOB (non-friable-NY) ____ _ Other ____ _ O OSHA ID-191 Modified D Standard Add1t1on Method 0 ~eek For Positive Stoa -Clea riv ldentifv Homoaenous Grouo I Date Samoled: Samplers Name: tJ! t L S0l,· , I Samplers Signature: k#Y- ' Sample# HA# Sam nle Location )(-iil t,\. !:- I (--,k c " Z5"c, Jc.-JB I I -x. -) (._ I I ,\ t )Ji 1 ,., /....-I v li 'L I ll 'tr-)l 1-I k > a ~ -'::> _A--j ) t· Material Descriotion ,, S'v4i'"-' ·~l-•\ ·,.; 1, /1 -J ;, !, /c-6' p J l'-It J JI'.-!_JA L/ )l ~g L/ \I I , Client Sample# (s): ---~k~ c.1_71_-__ 157 -'> Total# of Samples: Gr Relinquished (Client): Date: Time: Received (Lab): . L---' Date: (, I J --, I ,, ,---, Time: Sn - Comments/Special Instructions: -' Controlled Document -Asbes1os COC -R2 -41912013 Page 1 of __j__ pages I OrderID: 291603781 Page 2 Of 4 A!':h~!':tos Bulk Buildina Material EMSL ANALYTICAi .. INC -ENTRE BL';O SUITE 6GJ E:MSL ANALYT LABORATOFfY•PROCU Atlantic Shores Environmental Svcs., Ltd 1272A 6/10/2016 15 30 PLM TAT: 24 Hour Bulk OrderlD: 291603781 No Samples: 68 Due: 06/11 3:00 PM Fax: 91Cl-371-6652 ., NC 27S6C, 9-465-3S);}J Additional Pages of the Chain of Custody are only necessary if needed for additional sample information Sample# HA# Sample Location Material Descriotion }(.-·i A r ~ •'- -,. \~:,c, ti· tb .-i \a:.\....,) be .. l ~LI..,'-J\.,1<....\ f-'(._ j I )l. 'j 13 ) \'-!; k '5 C.. ) \ '-ll c ,, A, c \ I: -le A C-l)LJ /:f L r~;J \ ,\t,-{ '-' )('. -lt 1$ (_, ,, " K-1,c L-h 1, i(-1 /:, ' )..x )_ pc, .. ~ (T . t-11> "] k " Ii. -1 (_ ' k ;, /l [A q I) ~0 / YL. .A Jd. \ ·~ ,, (, IL·!'> (> JC YL y I, I, ):. <J _,4 a MV I+ (_, 5{af,,~~ ~ -') 13 1 I l,, !; 5-)oA b Un,VJ,:;, l 1 f. ·f ,C. 5h£\.-J /t:t:'•:A. 5 ,"1 :c .I k (T s M.-t. ~-.l't..'lv\.'\.._ 5 )NS 2(} " 1, 5 /e,1 ( '7f~I •\ '/ S-J/ ,~ " I v ,: )-.i--,) Cr 3 hcv·vi(1;:.1 ~"'\. 5 )_/ 1> 2-1 \\ I, s ).\ (_ • I ,. ,, u/ ' g-7A '?._-:-] iVi,,,-.,, ~..,.,,,,_ + ,?.,-i . .';-t <)' /.!. l., (f ).1 ,~1. ' c:I t V; ~ \..AJ I.,"\. /Z-7 5 (1_, 7 ~ (~ ,, /?.. 7 ( r-1 \ ,/ 1~ .,_ *Comments/Special Instructions: 1 i Page~-of~-pages Controlled Document -Asbestos COC -R2 -4.'0.'20 1 J OrderID: 291603781 Page 3 Of 4 Asbestos Bulk Building Material EMSL ANALYTICAL. INC ,;r::nr-. r.;ATEWAY CENTRE 8L1JO SUITE 6DC )RRISVILLE. NC 27Ssc, Atlantic Shores Environmental Svcs., Ltd 1272 A ' 6110/20161530 TAT: 24 Hour PLM Bulk Order ID: 291603781 No Samples: 68 Due: 06/11 3:00 PM Fax: 910-371-6652 PHONE 919-465-390J FAX. 9 I 9-4(:L~:-J::i~,~· Additional Pages of the Chain of Custody are only necessary if needed for additional sample information Sample# HA# Sample Location Material Descriotion f fit f?.--'t A I,, : '\ k.,...,LU .1 ,1, I,\\,., l-/ L!A (__ _S'tc, \,"'-\-t \ ' ,., ~<, \,,. (.-::,o..r -~ t-'f \:S (?_ 5 j .,, r', ,o .), ' '"'---Jxl ll-C\ .A R,_ 'i (, ls',: ~I,,·"'''"" -,,1, r '\ 15 f •' I 1, /) {2-'] {____ /2 'f 1, It )Z-iv ,4 /(_ -/0 /T LtJ Lt ...,~rot1 J-""\. J,...j e-lo i) f-tv \\ 1, (2-\o L l'lf<.J LT <-_;J,,1-.-..__, it,(. ...... ~-.J . f JIA I I I i<.· (_ l(. • f'A.,, 1A,_ j:T V'2/1 v\1· ·,; L (!.110 fl; I l~ I/ )? I! A /2fl--))Ln th '3 hz.,"" J,cr ;5,e ,,Iµ ,,,j '{'. 11 ~ I • f'r l 1-~ £-15 ·\ /2;3 5, .. lvi \ 6_;,;." ,IM 1-,.( ,, c -b 1,i/C P.-l>l';, /)_/ ':, 1, ,, fH A (LI'-/ (-}1i0t.k · ... ,l-(,.:c:J-(,_,,,c,r ~ ,~ l,., ~ J2H / 3,. J?-1'1/ ,,, '1 £-ic; 4 f;J Dr ivt. +iN J,,<-r c\J .',J,;,..,-\ i<.u "'-, v 12-is-13 r2 )J , '-~ '7 i,2-/ I; ,_'./ /!.! (, (,, ul le "'~ I=, x-is- /-/(, J I 11 {?-lk;)) \ I \\ )5 -I &! /l,)1 J,,c!y s;i.-,., ~0-A-\ Ale: ~Le Jui--n.k ,/' Se~·-fa\A. + 8 J-A ' __., f!,L {T ) , '-l </ )C"'U •""-- B-;_ 13 f, 2 ,l ,,, l) 1.C f,L \ J "" ,j .. Comments/Special Instructions: Page _3___ of _j__ pages Controlled Document -Asbestos COC -R2 -419.'20 1 3 OrderID: 291603781 Page 4 Of 4 • EMSL ANALYTIC/. CA9QJIATOflV•POIOtlV(:T$• Asbestos Bulk Building Material Atlantic Shores Environmental Svcs., Ltd 1272 A 6/10/20161530 PLM TAT: 24 Hour Bulk Order ID: 291603781 No Samples: 68 Due: 06111 3 00 PM Fax: 910-371-6652 EMSL ANALYTICAL. INC ?t;()() GATf=\~,/4Y r.i::NTRE BL\/[) SU!TE 6C:,'~, JC 27Sf:=iC Additional Pages of the Chain of Custody are only necessary 1f needed for additional sample information Sample# HA# Sample Location Material Description lJ > ,1\ ~-_s Ac. 1.c &-"', 3[.,, . ., !Sc J),--.J / J L ,{ -w..., }, p • (•'-!-l l J Jf ,-:;B ~-3 [\ I ' ,'-i-5 C e-3 I\ I/ l3-1,1/\ Cs -Y B., ri,,,-:~ ,,, j: :;,,~~-r !3'·4J (3 i.j I\ /} $-'i A IP, J-/2 x I l FT ,,/,-,1,s)'' L Ii'..-s l3 ig (' C\ I; /} (;,AC & l. t.1l t6c_,,J ,&!,,:,./,(_ A I l.{ t·- 13 ~ ,::, f3 (., ,, ' /, ff 7A £ 1 -I :5.,_,-Jl, D,:cJc ,;,,k.,.cr S-,-i«--1 ~ g-13 8-7 " 'I " "'Comments/Special Instructions: Page __1____ of_"\ __ pages Ct:mlrollra Document -Asbestos C::'.lC -R2 -4/9:20 T 3. EMSL Analytical, Inc. 2500 Gateway Centre Blvd., Suite 600 Morrisville, NC 27560 Tel/Fax: (919) 465-3900 / (919) 465-3950 http://www.EMSL.com / raleighlab@emsl.com 291604081EMSL Order: Customer ID:ATLS78 Customer PO: Project ID: Attention:Phone:Cheryl Moody (910) 371-5980 Fax:Atlantic Shores Environmental Svcs., Ltd (910) 371-6652 Received Date:154 Backhoe Road 06/23/2016 10:00 AM Analysis Date:Leland, NC 28451 06/23/2016 Collected Date:06/19/2016 Project:1272A Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy Sample Description Appearance % Fibrous % Non-Fibrous Non-Asbestos Asbestos % Type R-3C 291604081-0001 3% ChrysotileNon-fibrous (Other)95%Cellulose2%Black/Yellow Fibrous Heterogeneous Maintenance and Repair Bldg - 12x12 Tile w/ Mastic Analyst(s) Olivia Bradley (1)Billy Barnes, Asbestos Lab Manager or Other Approved Signatory EMSL maintains liability limited to cost of analysis. This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1% Samples analyzed by EMSL Analytical, Inc. Morrisville, NC NVLAP Lab Code 200671-0, VA 3333 000278, WVA LT000296 Initial Report From: 06/23/2016 11:57:49 Page 1 of 1PLM - 1.69 Printed: 6/23/2016 11:57 AM OrderID: 291604081 Page 1 Of 1 EMSL Analytical, Inc. ~~cShores Environmental Sv~ .• Ud ·------·-~rde~.1~/~1:~-;1--:.-.l 2500 Gateway Centre Bouleva -------- eM< 6/23/2016 10:0 PLM I TAT: 24Hour Bulk No Samples: 1 Due: 06/2410.00 AM Fax: 910-371-6652 ~. NC 27560 •19-465-3900 119-465-3950 Comnanv: Atlantic Shores Environmental Svcs., Ltd EMSL-Bill to: 0 Same D Different If 8111 to Is Different note instructions in Comments•• Street: 154 Backhoe Road Third Part.v Bil/inn requires written authorization from third nartv Citv: Leland I State/Province: NC Zin/Postal Code: 28451 l Count=: US Report To INamel: Elliot Swain Telephone#: 910-371-5980 Email Address: eswain@atlanticshoresenv.com Fax#: 910-371-6652 I Purchase Order: Pro;ect Name/Number: 1272A Please Provide Results: I IF ax I v' Email I Mail U.S. State Samnles Taken: NC CT Samples: D Commercialffaxable D Residential/Tax Exemot _ Turnaround Time (TAT) Options* -Please Check D 3 Hour I D 6 Hour I ,..., 24 Hour ID 48 Hour I D 72 Hour 10 96 Hour ID 1 Week IO 2Week *For TEM Air 3 hr through 6 hr, please call ahead to schedule. *There is a premium charge for 3 Hour TEM AHERA or EPA Level II TAT. You will be asked to sign an authorizatwn form for this service. Analvsis comoleted in accordance with EMSL 's Terms and Conditions located in the Analvlica/ Price Guide. PLM ~ Bulk {reBorting limit} TEM-Bulk M EPA 600/R-93/116 (<1%) O TEM EPA NOB -EPA 600/R-93/116 Section 2.5.5.1 ----------------------- 0PLM_EJ'_II_NOB(<1%) ·--·---------___________ . 0 NY ELAP Method 198.4 (TEM) ---------------·· ·--Point Count D 400 (<0.25%) D 1000 (<0.1%) D Chatfield Protocol (semi-quantitative) ~0nt Count w/S,ravimetric O 400 (<0.25°/,U;=l _1 O_C!2_l<9.1 %)__ 0 _TEl-1~_by ~ass -EPA 600/R-93/116 Section 2.~.5.2 _ 0 NIOSH~(<1%) _ -------------__ D TEM Qualitat.i?e via Filtration Prep Technique _ --------O NY ELAP Method 198.1 (friable in NY) D TEM Qualitative via Drop Mount Prep Technique O NY ELAP Method 198.6 NOB (non-friable-NY) Other O OSHA ID-191 Modified --D ---------------------------D Standard Addition Method ~ck For Positive Stoo -Clearlv Jdentifv Homogenous Group J Date Sampled: 1u/!1/1, Sampler~ Name:[J/.~iSv->•·i,... /{1-uy I )),4 I ~amplers-~ignature: ~~ -------- Sample# HA# Sample Location Material Descriotion rt-3L 3 )l11).,,./,111an1.<-tmJ If A \f-t.?u:IJ~ ?}_;( ll.. J·4 w/.11.~~'L. ~ Client Sample# Isl: E-f~/ -Total# of Sam oles: I Relinquished (Client): // _,.,,/A----Date: ,:; /, t,;JJ L, Time: )l .'r' Received (Lab):'\?..t\ ~ ~ / Time: I 0<=-1'Y\ Date: In-'Z 1 -\ k, Comments/Special Instructions: J\J;-~ 11. ({ d Mt•:> t:1 frt1M i-1-1. f(J/ 5A""i'" i-J fit V)v~\;,' S., h,."· H-< ) • Page 1 of _I_ pages E r'.:. ~ c-f fC(S-( ~ ( ~q Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A 1 Photograph 1 – HVAC duct sealant Photograph 2 –HVAC duct sealant Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A  2 Photograph 3 – Maintenance & Repair building locker room tile and mastic Photograph 4 – Maintenance & repair building. Sealant between metal and cinderblock. Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A 3 Photograph 5 – Auto body shop roofing sealant on fume hoods. Photograph 6 – Auto body shop roofing sealant on fume hoods. Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A  4 Photograph 7 – Auto body shop roofing sealant on fume hoods close-up. Photograph 8 – Brown penetration sealant on auto body building (See Photo 12). Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A  5 Photograph 9 – Mastic in Parts Department located in Maintenance and Repair building Photograph 10 – Interior cinder block corner sealant in Maintenance and Repair building. Report of Asbestos Survey July 26, 2016 601 Willard Street and 600 Julian Car Street Durham, North Carolina ASE Project No. 1272A 6 Photograph 11 – Auto body building south door cinder block corner sealant. Photograph 12 – Roof sealant on auto body building SAMPLE ID PHOTOGRAPH NO.DESCRIPTION APPEARANCE ASBESTOS % TYPES CONDITION APPROXIMATE QUANTITY* R-3B-Mastic Maintenance & Repair Building - White FT 12x12 mastic - Parts Dept.Black/Yellow <1% Chrysotile R-3C Maintenance & Repair Building - White FT 12x12 mastic - Parts Dept.Black/Yellow 3% Chrysotile R-4A Maintenance & Repair Building - HVAC Duct Upstairs Storage Gray/White 25% R-4B Maintenance & Repair Building - HVAC Duct Upstairs Storage Gray/White Positive Stop (Not Analyzed) R-4C Maintenance & Repair Building - HVAC Duct Upstairs Storage Gray/White Positive Stop (Not Analyzed) R-11A-Floor Tile Maintenance & Repair Building - Locker FT w/ Mastic Gray/White 3.2% Chrysotile R-11A-Mastic Maintenance & Repair Building - Locker FT w/ Mastic Tan/Black 0.5% Chrysotile R-11B-Floor Tile Maintenance & Repair Building - Locker FT w/ Mastic Gray/White Positive Stop (Not Analyzed) R-11B-Mastic Maintenance & Repair Building- Locker mastic Fibrous 3.9% Chrysotile R-13A Maintenance & Repair Building - Sealand b/w Metal C-Block Gray/Black 8% Chrysotile R-13B Maintenance & Repair Building - Sealand b/w Metal C-Block Gray/Black Positive Stop (Not Analyzed) R-14A Maintenance & Repair Building- C-Block Interior corner sealant Gray/White 4.9% Chrysotile R-14B Maintenance & Repair Building- C-Block Interior corner sealant Gray/White Positive Stop (Not Analyzed) B-7A Auto Body Shop Building - South Door Interior Sealant Tan 0.9% Chrysotile B-7B Auto Body Shop Building - South Door Interior Sealant Tan 2.2% Chrysotile BR-1A Auto Body Shop Roof - Penetration Sealant - Fume Hoods Gray/White/Black 15% Chrysotile BR-1B Auto Body Shop Roof - Penetration Sealant - Fume Hoods Gray/White/Black Positive Stop (Not Analyzed) BR-2A Auto Body Shop Roof - Roof Sealant (Brown with outer layer)Brown/White/Silver 5% Chrysotile BR-2B Auto Body Shop Roof - Roof Sealant (Brown with outer layer)Brown/White/Silver Positive Stop (Not Analyzed) Non Friable 100 square- feet 1,100 square - feet Table 1. Positive Asbestos Results 1 and 2 9 3 4 10 11 5, 6 and 7 8 Non Friable Friable Non Friable Non Friable Non Friable Non Friable 20 linear feet 20 linear feet 1,520 square- feet 7 linear feet 270 square-feet 100 linear feet Non Friable feet meters 1000 400 FIGURE 1: ASBESTOS LOCATION MAP NApproximate Scale: Not to Scale Source: Google Earth 2013 Aerial Photograph ASE Project No. 1272A July 2016 University Ford Showroom/Office Space University Kia Showroom/Office Space Maintenance and Repair Building Paint and Body Building Asbestos Survey 601 Willard and 600 Julian Carr Street Durham, Durham County, North Carolina Duct wrap (mezzanine) Roof sealant - in rows on roof and around sky lights Corner sealant (typ) Corner sealant (typ) Roof penetration sealant (fume hoods and vents) Tile and/or mastic