Loading...
HomeMy WebLinkAboutWS-9844_45028_CA_WR_20240422Speedway 7940 Guilford College, NC- Monitoring Well Abandonment Letter April 2024 AECOM 919.461.1559 tel 5438 Wade Park Boulevard, Suite 200 Raleigh, NC 27607 April 22, 2024 Mr. Gene Mao Guilford County Department of Environmental Health 400 W. Market Street, Suite 300 Greensboro, NC 27401 AECOM Project #: 60687379 Subject:Monitoring Well Abandonment LetterSpeedway #7940 5729 W. Friendly AvenueGreensboro, NC 27410Guilford CountyIncident No. 45028 Dear Mr. Mao, Please see attached well abandonment form and photos associated with monitoring well MW-5.Monitoring well MW- 5 was abandoned on April 5, 2024.Should you have any questions concerning these activities please contact Nathan Pinsker with AECOM at 919-461-1559. Sincerely, Nathan Pinsker Marie TreiberProject Manager Regional Senior Program ManagerNathan.Pinsker@aecom.com Marie.Treiber@aecom.com Attachments: Attachment A Photographic Log Attachment B Well Abandonment Record Attachment A Photographic Log Page 1 of 1 Photographic Log Client Name: Speedway LLC. Site Location: Speedway #7940 Guilford College, NC Project No. 60687379 Photo No. 1 Date: 4/5/24 Direction Photo Taken: NA Description: MW-5 before and after abandonment. Attachment B Well Abandonment Record WELL ABANDONMENT RECORD This form can be used for single or multiple wells Form GW-30 North Carolina Department of Environment and Natural Resources Division of Water Quality Revised March 2013 1. Well Contractor Information: Well Contractor Name (or well owner personally abandoning well on his/her property) NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well construction permits (i.e. County, State, Variance, etc.) if known 3. Well use (check well use): Water Supply Well: Agricultural Municipal/Public Geothermal (Heating/Cooling Supply)Residential Water Supply (single) Industrial/Commercial Residential Water Supply (shared) Irrigation Non-Water Supply Well: Monitoring Recovery Injection Well: Aquifer Recharge Groundwater Remediation Aquifer Storage and Recovery Salinity Barrier Aquifer Test Stormwater Drainage Experimental Technology Subsidence Control Geothermal (Closed Loop)Tracer Geothermal (Heating/Cooling Return)Other (explain under 7g) 4. Date well(s) abandoned: 5a. Well location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W CONSTRUCTION DETAILS OF WELL(S) BEING ABANDONED Attach well construction record(s) if available. For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 6a. Well ID#: 6b. Total well depth:(ft.) 6c. Borehole diameter:(in.) 6d. Water level below ground surface:(ft.) 6e. Outer casing length (if known):(ft.) 6f. Inner casing/tubing length (if known):(ft.) 6g. Screen length (if known):(ft.) WELL ABANDONMENT DETAILS 7a. Number of wells being abandoned: For multiple injection or non-water supply wells ONLY with the same construction/abandonment, you can submit one form. 7b. Approximate volume of water remaining in well(s):(gal.) FOR WATER SUPPLY WELLS ONLY: 7c. Type of disinfectant used: 7d. Amount of disinfectant used: 7e. Sealing materials used (check all that apply): Neat Cement Grout Bentonite Chips or Pellets Sand Cement Grout Dry Clay Concrete Grout Drill Cuttings Specialty Grout Gravel Bentonite Slurry Other (explain under 7g) 7f. For each material selected above, provide amount of materials used: 7g. Provide a brief description of the abandonment procedure: 8. Certification: Signature of Certified Well Contractor or Well Owner Date By signing this form, I hereby certify that the well(s) was (were) abandoned in accordance with 15A NCAC 02C .0100 or 2C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 9. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well abandonment details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 10a. For All Wells:Submit this form within 30 days of completion of wellabandonment to the following: Division of Water Quality, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 10b. For Injection Wells:In addition to sending the form to the address in 10a above, also submit one copy of this form within 30 days of completion of well abandonment to the following: Division of Water Quality, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 10c. For Water Supply & Injection Wells:In addition to sending the form to the address(es) above, also submit one copy of this form within 30 days of completion of well abandonment to the county health department of the countywhere abandoned. For Internal Use ONLY: Lawrence D. Opper 3322-A Regional Probing Services 4/5/2024 MW-5 Speedway #7940 5729 W. Friendly Avenue, Greensboro Guilford 36.089381 79.888268 MW-5 30 well I.D.=2.0 approx 25 1 0 bentonite chips: 1.6 lbs/ft (48 lbs) Filled/ hydrated from bottom-up. Capped with stained concrete. Lawrence Opper Digitally signed by Lawrence OpperDN: cn=Lawrence Opper, o=RegionalProbingServices, ou,email=larry@regionalrprobing.com, c=USDate: 2024.04.21 11:30:17 -04'00'4/21/2024