HomeMy WebLinkAbout25050_Assistance League_Phase I ESA_20121101PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORT
FORMER CAROLINA MARKING DEVICES, INC.
3405 SOUTH TRYON STREET
CHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINA 28217
ECS PROJECT NO. 08-8606
FOR
THE ASSISTANCE LEAGUE OF CHARLOTTE
NOVEMBER 01, 2012
November 01, 2012
Mr. Randy Russell
The Assistance League of Charlotte
PO Box 471112
Charlotte, North Carolina 28247
ECS Project No. 08-8606
Reference:Phase I Environmental Site Assessment Report, Former Carolina Marking
Devices, Inc., 3405 South Tryon Street, Charlotte, Mecklenburg County,
North Carolina 28217
Dear Mr. Russell:
ECS Carolinas, LLP (ECS) is pleased to provide The Assistance League of Charlotte
with the results of our Phase I Environmental Site Assessment (ESA) for the referenced
property. ECS services were provided in general accordance with ECS Proposal No. 08-
14220P dated September 18, 2012 and generally meet the requirements of ASTM E
1527-05, Standard Practice for Environmental Site Assessments: Phase I Environmental
Site Assessment Process and EPA Standards and Practices for All Appropriate Inquiry
contained in 40 CFR Part 312.
If there are questions regarding this report, or a need for further information, please
contact the undersigned at (704) 525-5152.
ECS CAROLINAS, LLP
David E. Valentine
Environmental Technician
Brian E. Maas, REM
Director of Environmental Services
ECS Project No. 08-8606
November 01, 2012
ENVIRONMENTAL PROFESSIONAL STATEMENT
We declare that, to the best of our professional knowledge and belief,we meet the
definition of Environmental Professional as defined in § 312.10 of 40 CFR 312. We have
the specific qualifications based on education, training, and experience to assess a
property of the nature, history, and setting of the subject property.We have developed
and performed all appropriate inquiries in conformance with the standards and practices
set forth in 40 CFR Part 312.
Brian E. Maas, REM November 01, 2012
Director of Environmental Services
Phase I Environmental Site Assessment Report
Former Carolina Marking Devices, Inc.
3405 South Tryon Street
Charlotte, Mecklenburg County, North Carolina 28217
CLIENT
The Assistance League of Charlotte
PO Box 471112
Charlotte, North Carolina 28247
SUBMITTED BY
ECS Carolinas, LLP
1812 Center Park Drive
Suite D
Charlotte, North Carolina 28217
PROJECT 08-8606
DATE November 01, 2012
PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORT
FORMER CAROLINA MARKING DEVICES, INC.
3405 SOUTH TRYON STREET
CHARLOTTE, NORTH CAROLINA 28217
ECS PROJECT NO. 08-8606
SECTION PAGE
1.0 EXECUTIVE SUMMARY ................................................................................1
2.0 INTRODUCTION.............................................................................................3
2.1 Purpose and Reason for Performing Phase I ESA.................................3
2.2 Scope of Services...................................................................................3
2.3 Limitations ..............................................................................................3
3.0 SITE DESCRIPTION.......................................................................................5
3.1 Site Location and Legal Description.......................................................5
3.2 Physical Setting and Hydrogeology........................................................5
3.3 Current Use and Description of the Site.................................................6
3.4 Current Uses of the Adjoining Properties ...............................................6
4.0 USER PROVIDED INFORMATION ................................................................7
4.1 Title Information......................................................................................7
4.2 Environmental Liens or Activity and Use Limitations..............................7
4.3 Specialized Knowledge ..........................................................................7
4.4 Commonly Known or Reasonably Ascertainable Information ................7
4.5 Valuation Reduction for Environmental Issues.......................................7
4.6 Owner, Property Manager, and Occupant Information...........................7
4.7 Degree of Obviousness ..........................................................................7
5.0 RECORDS REVIEW .......................................................................................8
5.1 Federal Databases .................................................................................9
5.2 State Databases...................................................................................11
5.3 Historical Use Information ....................................................................15
6.0 SITE AND AREA RECONNAISSANCE .......................................................19
6.1 Methodology and Limiting Conditions...................................................19
6.2 On-Site Features ..................................................................................19
6.3 Adjoining and Nearby Properties..........................................................21
7.0 ADDITIONAL SERVICES.............................................................................22
7.1 Non-Scope Issues ................................................................................22
7.2 Previous Reports Review .....................................................................22
8.0 INTERVIEWS................................................................................................23
9.0 FINDINGS .....................................................................................................24
10.0 CONCLUSIONS AND OPINIONS ................................................................26
11.0 REFERENCES..............................................................................................27
Table of Contents
Page 2
APPENDICES
I Figures
II Correspondence and User Questionnaire
III Regulatory Records Documentation
IV Historical Research Documentation
V Site Photographs
VI Statement of Qualifications
ECS Project No. 08-8606
November 01, 2012
-1 -
1.0 EXECUTIVE SUMMARY
ECS Carolinas, LLP was contracted by The Assistance League of Charlotte to perform
an ASTM Standard E-1527-05, Phase I Environmental Site Assessment (ESA) for a site
located at 3405 South Tryon Street in Charlotte, Mecklenburg County, North Carolina.
According to the Mecklenburg County tax information system, the site is identified as
Parcel ID No. 14702131.Any exceptions to or deletions from this practice are described
in Section 2.3 of this report.
The site is an approximate 3.03 acre tract located at 3405 South Tryon Street in
Charlotte, Mecklenburg County, North Carolina.The site is developed with an
approximate 24,000 square foot, one-story commercial warehouse.The building was
constructed in 1991 and was formerly occupied by Carolina Marking Devices, Inc.The
site was used for production of marking devices (stamps, badges, notary seals, etc.) that
utilized various inks.The building contains a showroom, offices, a production area and a
warehouse.The remainder of the site consists of an asphalt paved parking lot and
landscaped areas.The site is provided water and sanitary sewer services through the
Charlotte Mecklenburg Utilities Department.The site is provided natural gas through
Piedmont Natural Gas.ECS did not observe underground storage tanks (USTs)
associated with the site.
ECS observed two air compressors in the building that were leaking oil.The oil
appeared to have traveled into cracks in the concrete flooring.ECS considers the oil
from the air compressors to be a recognized environmental condition (REC) of the site.
ECS observed five groundwater monitoring wells located on the site.The monitoring
wells are associated with on-going remediation activities from the former Pelton & Crane
facility as discussed in Section 5.2.ECS considers these monitoring wells to be RECs
of the site.
ECS reviewed historical aerial photographs and city directories for the subject site and
surrounding areas.The aerial photograph review depicted the site to be historically
undeveloped until the current facility was constructed in 1991.Surrounding properties
were historically developed with residential and commercial structures.The site is listed
as Carolina Marking Devices, Inc. and Caromark Stamps and Signs in the 2005 city
directory. In the 2000, 1995 and 1992 city directories, the site is listed as Carolina
Marking Devices, Inc. The site is not listed prior to the 1992 city directories.The site is
currently bounded on the north by CATS bus facility; on the east by goodmortgage.com
and Lifespan; on the south by USTT, Hertron, Staffzone and C.A.R.S.; and, on the west
by South Tryon Street, 77 Corporate Park and Fast Signs.
The site is located in a commercial/residential area of Charlotte, North Carolina. A
regulatory records search report, dated October 8, 2012 of ASTM standard and
supplemental databases was prepared for the site by FirstSearch. FirstSearch identified
multiple properties within the search distance of inquiry and one to be of environmental
concern with respect to the site:
ECS Project No. 08-8606
November 01, 2012
-2 -
·Pelton & Crane Plant (Former), 200 Clanton Road -located on the adjoining
property to the east and topographically upgradient of the site.According to the
FirstSearch report, this facility formerly operated one 2,000-gallon oil UST and
one 650-gallon oil UST.ECS reviewed regulatory files regarding this facility.
During the removal of the USTs soil and groundwater contamination were
identified.The contaminants identified included metals, chlorinated organic
solvents and polyaromatic hydrocarbons.Contamination was discovered on the
subject site (3405 South Tryon Street) along the eastern site boundary and in the
creek bed.Soil remediation was completed in 2008. Groundwater source
treatment has been conducted since 2005.Monitoring wells located on the
subject site indicate elevated groundwater contaminants.The monitoring wells
indicated that the groundwater flows radially from the facility towards the
southwest, west and northwest.Additional remediation activities are planned for
2013.In October 2012,deep soil gas samples were collected on the subject site
to evaluate the potential for vapor intrusion. The samples collected were below
the state's industrial/commercial vapor intrusion levels.Based on contamination
being identified on-site, ECS considers the release associated with this off-site
facility to be an REC of the site.
As documented and qualified by this report, this assessment has revealed the following
evidence of RECs in connection with the property:
On-Site:
Potential exists that the discharge oil from the air compressors could impact soil and/or
groundwater beneath the site.ECS recommends additional assessment to determine if
soil and/or groundwater beneath the site has been impacted.
ECS observed five groundwater monitoring wells on-site that are associated with on-
going remediation activities at the former Pelton & Crane facility located on the adjoining
property to the east.
Off-Site:
The former Pelton & Crane facility located on the adjoining property to the east is
currently undergoing remediation activities.ECS recommends that the responsible party
continue with remediation activities for the former Pelton & Crane facility.ECS also
recommends requesting and periodically reviewing sampling and reporting conducted by
the responsible party and having a qualified environmental professional review the
findings.
This Executive Summary is an integral part of the Phase I Environmental Site
Assessment report. ECS recommends that the report be read in its entirety.
ECS Project No. 08-8606
November 01, 2012
-3 -
2.0 INTRODUCTION
2.1 Purpose and Reason for Performing Phase I ESA
The purpose of the ESA was to:
·evaluate the probability of impact to the surface water, groundwater and/or soils
within the property boundaries through a review of regulatory information and a
reconnaissance of the subject site and vicinity;
·evaluate historical land usage to identify previous conditions that could potentially
impact the environmental condition of the site;
·evaluate the potential for on-site and off-site contamination;
·provide a professional opinion regarding the potential for environmental impact at
the site, and a list of Recognized Environmental Conditions; and,
·conduct all appropriate inquiry as defined by ASTM-E 1527-05
The reason for the ESA is to qualify for landowner liability protections to CERCLA
liability.
2.2 Scope of Services
The environmental assessment was conducted in accordance with ASTM E 1527-05
and EPA Standards and Practices for All Appropriate Inquiry (40 CFR §312.10). The
environmental assessment was conducted under the supervision or responsible charge
of an individual that qualifies as an environmental professional, as defined in 40 CFR
§312.10.
ECS Carolinas, LLP was contracted by The Assistance League of Charlotte to perform a
Phase I ESA for property located at 3405 South Tryon Street, Charlotte, Mecklenburg
County, North Carolina. The site is identified as Mecklenburg County Parcel ID No.
14702131.
2.3 Limitations
The ESA involved a reconnaissance of the site and contiguous properties and a review
of regulatory and historical information in accordance with the ASTM standard and EPA
regulation referenced herein. No non-scope considerations or additional issues such as
asbestos, radon, wetlands or mold were investigated, unless otherwise described in
Section 7.0 of this report.
ECS Project No. 08-8606
November 01, 2012
-4 -
The conclusions and/or recommendations presented within this report are based upon a
level of investigation consistent with the standard of care and skill exercised by members
of the same profession currently practicing in the same locality under similar conditions.
The intent of this assessment is to identify the potential for recognized environmental
conditions in connection with the site; however, no environmental site assessment can
completely eliminate uncertainty regarding the potential for recognized environmental
conditions in connection with the site. The findings of this ESA are not intended to serve
as an audit for health and safety compliance issues pertaining to improvements or
activities at the site. ECS is not liable for the discovery or elimination of hazards that
may potentially cause damage, accidents or injury.
Observations, conclusions and/or recommendations pertaining to environmental
conditions at the subject site are necessarily limited to conditions observed, and or
materials reviewed at the time this study was undertaken. It was not the purpose of this
study to determine the actual presence, degree or extent of contamination, if any, at this
site. This could require additional exploratory work, including sampling and laboratory
analysis. No warranty, expressed or implied, is made with regard to the conclusions
and/or recommendations presented within this report.
ASTM E-1527-05 defines a "recognized environmental condition" as "the presence or
likely presence of any hazardous substances or petroleum products on a property under
conditions that indicate an existing release, a past release, or a material threat of a
release of any hazardous substances or petroleum products into structures on the
property or into the ground, groundwater, or surface water of the property. The term
includes hazardous substances or petroleum products even under conditions in
compliance with laws. The term is not intended to include de minimis conditions that
generally do not present a threat to human health or the environment and that generally
would not be the subject of an enforcement action if brought to the attention of
appropriate governmental agencies."
ASTM E-1527-05 defines a “business environmental risk” as “a risk which can have a
material environmental or environmentally-driven impact on the business associated with
the current or planned use of a parcel of commercial real estate”. Client-imposed
limitations and site condition limitations, if encountered, are detailed in Section 6.1
Methodology and Limiting Conditions.
This report is provided for the exclusive use of The Assistance League of Charlotte. This
report is not intended to be used or relied upon in connection with other projects or by
other unidentified third parties. The use of this report by undesignated third party or
parties will be at such party’s sole risk and ECS disclaims liability for such third party use
or reliance.
ECS Project No. 08-8606
November 01, 2012
-5 -
3.0 SITE DESCRIPTION
3.1 Site Location and Legal Description
The site referred to as “subject site”or “site” is located at 3405 South Tryon Street
Charlotte, Mecklenburg County, North Carolina (Figure 1, Appendix I). A legal
description of the property was not provided to ECS.
3.2 Physical Setting and Hydrogeology
As determined from the USGS Topographic Map, Charlotte West & Charlotte East,
North Carolina Quadrangles (Figure 1), the site’s elevation is approximately 720 feet
above mean sea level.Surface runoff on the site generally flows to the west-northwest
toward an unnamed tributary of Irwin Creek.Limited areas to the northeast-east appear
to be upgradient of the site based on the groundwater flow direction inferred from the
surface topography.
According to the Geologic Map of North Carolina (1985), the subject property is situated
in the Charlotte Belt of the Piedmont Physiographic Province with the underlying bedrock
composed of metamorphosed mafic rock. The Piedmont Physiographic Province is
characterized by gently rolling topography, deeply weathered bedrock, and a relative
paucity of solid outcrop. Rocks are strongly weathered in the Piedmont's humid climate
and bedrock is generally buried under a thick (2-20 m) blanket of saprolite. Outcrops are
commonly restricted to stream valleys where saprolite has been removed by erosion.
The topography becomes somewhat more rugged with proximity to the Blue Ridge,
where local monadnocks of more resistant rock occur.
The soils encountered in this area are the residual product of in-place chemical
weathering of rock presently underlying the site. In general, shallow unconfined
groundwater movement within the overlying soils is controlled largely by topographic
gradients. However, as the groundwater percolates downward to the bedrock, it
becomes controlled by the orientation of the rock fracture systems. Thus, the direction of
groundwater movement may not be consistent with the reflecting topography. Recharge
occurs primarily by infiltration along higher elevations and typically discharges into
streams or other surface water bodies. The elevation of the shallow water table is
transient and can vary with seasonal fluctuations in precipitation. Movement of
groundwater under water table conditions is generally from higher to lower elevations.
As such, shallow groundwater would be expected to flow to the west-northwest beneath
the site. Actual site groundwater flow direction cannot be determined without site-specific
groundwater information determined through the installation of groundwater monitoring
wells.
ECS Project No. 08-8606
November 01, 2012
-6 -
3.3 Current Use and Description of the Site
The site is an approximate 3.03 acre tract located at 3405 South Tryon Street in
Charlotte, Mecklenburg County, North Carolina.The site is developed with an
approximate 24,000 square foot, one-story commercial warehouse.The building was
constructed in 1991 and was formerly occupied by Carolina Marking Devices, Inc.The
building contains a showroom, offices, a production area and a warehouse.The
remainder of the site consists of an asphalt paved parking lot and landscaped areas.
3.4 Current Uses of the Adjoining Properties
The site is bounded on the north by CATS bus facility; on the east by
goodmortgage.com and Lifespan; on the south by USTT, Hertron, Staffzone and
C.A.R.S.; and, on the west by South Tryon Street, 77 Corporate Park and Fast Signs.
Additional information regarding the adjoining and nearby properties is located in Section
6.3.
ECS Project No. 08-8606
November 01, 2012
-7 -
4.0 USER PROVIDED INFORMATION
ECS was not provided with a User Questionnaire for our review. ECS considers this a
data failure (historical data gap). If this information is provided at a later date, ECS will
review it for evidence of environmental concerns and issue an addendum to this report it
the review indicated a material difference in our findings. However, based on other
historical information presented, ECS considers this data failure to be non-significant.
This data failure has not affected ECS’s ability to identify Recognized Environmental
Conditions (RECs) relative to the site.
4.1 Title Information
ECS was not provided with a chain-of-title for our review.
4.2 Environmental Liens or Activity and Use Limitations
At the time of this report, ECS was not provided with the environmental lien or activity
and land use limitations for the subject site.
4.3 Specialized Knowledge
At the time of this report, ECS was not provided with specialized knowledge for the
subject site.
4.4 Commonly Known or Reasonably Ascertainable Information
At the time of this report, ECS was not provided with commonly known or reasonably
ascertainable information for the subject site.
4.5 Valuation Reduction for Environmental Issues
At the time of this report, ECS was not provided with information regarding valuation
reduction for environmental issues for the subject site.
4.6 Owner, Property Manager, and Occupant Information
According to the Mecklenburg County tax information, the owner of the site is Soloman
Shapiro.
4.7 Degree of Obviousness
At the time of this report, ECS was not provided with degree of obviousness information
for the subject site.
ECS Project No. 08-8606
November 01, 2012
-8 -
5.0 RECORDS REVIEW
A regulatory records search of ASTM standard and supplemental databases was
conducted for the site and is included in Appendix III. The regulatory search report in the
appendix includes additional details about the regulatory databases that were reviewed.
The regulatory records search involves searching a series of databases for facilities that
are located within a specified distance from the subject property. The ASTM standard
specifies an approximate minimum search distance from the subject site for each
database. Pursuant to ASTM, the approximate minimum search distance may be
reduced for each standard environmental record except for Federal NPL site list, and
Federal RCRA TSD list. According to ASTM, government information obtained from
nongovernmental sources may be considered current if the source updates the
information at least every 90 days or, for information that is updated less frequently than
quarterly by the government agency, within 90 days of date the government agency
makes the information available to the public. The following table indicates the standard
environmental record sources and the approximate minimum search distances for each.
Standard Environmental Record
Sources
Approximate Minimum Search
Distance Per ASTM (miles)
Federal NPL 1.0
Federal Delisted NPL 0.5
Federal CERCLIS 0.5
Federal CERCLIS NFRAP 0.5
Federal RCRA CORRACTS 1.0
Federal RCRA non-CORRACTS TSD 0.5
Federal RCRA Generators Subject Site and Adjoining Properties
Federal IC/EC Subject Site Only
Federal ERNS Subject Site Only
State and Tribal Hazardous Waste Sites
(NPL Equivalent)1.0
State and Tribal Hazardous Waste Sites
(CERCLIS Equivalent)0.5
State and Tribal Landfill and/or solid
waste disposal sites 0.5
State and Tribal LUST 0.5
State and Tribal Registered UST Subject Site and Adjoining Properties
State and Tribal IC/EC Subject Site Only
State and Tribal Voluntary Cleanup
(VCP) Sites 0.5
State and Tribal Brownfield Sites 0.5
ECS Project No. 08-8606
November 01, 2012
-9 -
Based on our knowledge of the subject property and the surrounding area, ECS
attempts to verify and interpret this data. While this attempt at verification is made with
due diligence, ECS cannot guarantee the accuracy of the record(s) search beyond that
of information provided by the regulatory report(s). Mapped and unmapped sites
identified in the regulatory report(s) that are not addressed below were field verified and
are not believed to be within the approximate minimum search distance and are
excluded from this ESA report. ECS makes no warranty regarding the accuracy of the
database report information included within the regulatory report(s).
ECS maintained the ASTM recommended search distances during this assessment.
5.1 Federal Databases
Federal National Priorities List (NPL)
The NPL is a subset of Comprehensive Environmental Response, Compensation, and
Liability Information System (CERCLIS) and identifies “superfund” sites that have had
documented contamination incidents.
The site was not identified on the NPL.
No off-site properties within the minimum search distance of inquiry were reported as
being on the NPL.
Federal Delisted NPL
The Delisted NPL identifies sites previously listed on the NPL where no further response
is appropriate.
The site was not identified on the Delisted NPL.
No off-site properties within the minimum search distance of inquiry were reported as
being on the Delisted NPL.
Federal CERCLIS
CERCLIS contains data on potential hazardous waste sites that have been reported to
the United States Environmental Protection Agency (USEPA). CERCLIS contains sites
that are either proposed to or on the NPL and sites which are in the screening and
assessment phase for possible inclusion on the NPL.
The site was not identified on the CERCLIS database.
No off-site properties within the minimum search distance of inquiry were reported as
being on the CERCLIS database.
Federal CERCLIS No Further Remedial Action Planned (NFRAP)
CERCLIS sites designated as NFRAP have been removed from CERCLIS. NFRAP sites
may be sites where, following an initial investigation, no contamination was found,
contamination was removed quickly without the need for the site to be placed on the
NPL, or the contamination was not serious enough to require federal Superfund action or
NPL consideration.
ECS Project No. 08-8606
November 01, 2012
-10 -
The site was not identified on the CERCLIS NFRAP.
One or more off-site properties within the minimum search distance of inquiry were
reported as being on the CERCLIS NFRAP database.
The FirstSearch report identified three properties within the search distance of inquiry.
Based on the distance from the site and/or the presumed groundwater flow direction
inferred from surface topography, ECS does not consider these facilities to be RECs of
the site.
Federal Corrective Action Report (CORRACTS)
CORRACTS identifies hazardous waste handlers that have been subject to corrective
action under Resource Conservation and Recovery Act (RCRA).
The site was not identified by CORRACTS.
No off-site properties within the minimum search distance of inquiry were reported as
being on CORRACTS.
Federal Resource Conservation and Recovery Information System (RCRIS)–
Treatment, Storage and Disposal (TSD)Facilities
RCRIS identifies facilities that treat, store or dispose of hazardous wastes as defined by
the RCRA. TSDs treat, store or dispose of hazardous waste.
The site was not identified as a hazardous waste TSD facility.
No off-site properties within the minimum search distance of inquiry were reported as
being a hazardous waste TSD facility.
Federal RCRIS -Generators
RCRIS identifies facilities that generate hazardous wastes as defined by the RCRA.
Conditionally exempt small quantity generators generate less than 100 kilograms of
hazardous waste, or less than 1 kilogram of acutely hazardous waste, per month. Small
quantity generators (SQGs) generate between 100 and 1,000 kilograms of hazardous
waste per month. Large quantity generators (LQGs) generate more than 1,000 kilograms
of hazardous waste or more than 1 kilogram of acutely hazardous waste per month.
The site was not identified as a hazardous waste generator.
No off-site properties within the minimum search distance of inquiry were reported as
being a hazardous waste generator.
Federal Engineering Controls (EC) List
The Federal EC list identifies engineering controls including various forms of caps,
building foundations, liners, and treatment methods used to eliminate pathways for
regulated substances to enter environmental media or affect human health.
The site was not identified on the EC list.
ECS Project No. 08-8606
November 01, 2012
-11 -
Federal Institutional Controls (IC) List
The Federal IC list identifies institutional controls including administrative measures,
such as groundwater use restrictions, construction restrictions, property use restrictions,
and post remediation care requirements intended to prevent exposure to contaminants.
The site was not identified on the IC list.
Federal Emergency Response Notification System (ERNS)
The ERNS list is a national database that stores and records information on reported
releases of hazardous substances, including petroleum products.
The site was not identified on the ERNS list.
5.2 State Databases
Incident Management Database (IMD)
The IMD, maintained by NCDENR-DWM, is a record of groundwater and soil
contamination incidents.
The site was not identified on the IMD.
One or more off-site properties within the minimum search distance of inquiry were
reported as being on the IMD.
·Pelton & Crane Plant (Former), 200 Clanton Road -located on the adjoining
property to the east and topographically upgradient of the site.According to the
FirstSearch report, this facility formerly operated one 2,000-gallon oil UST and
one 650-gallon oil UST.ECS reviewed regulatory files regarding this facility.
During the removal of the USTs soil and groundwater contamination were
identified.The contaminants identified included metals, chlorinated organic
solvents and polyaromatic hydrocarbons.Contamination was discovered on the
subject site (3405 South Tryon Street) along the eastern site boundary and in the
creek bed.Soil remediation was completed in 2008. Groundwater source
treatment has been conducted since 2005.Monitoring wells located on the
subject site indicate elevated groundwater contaminants.The monitoring wells
indicated that the groundwater flows radially from the facility towards the
southwest, west and northwest.Additional remediation activities are planned for
2013.In October 2012,deep soil gas samples were collected on the subject site
to evaluate the potential for vapor intrusion. The samples collected were below
the state's industrial/commercial vapor intrusion levels.Based on contamination
being identified on-site, ECS considers the release associated with this off-site
facility to be an REC of the site.
·77 Corporate Park, Clanton Road & South Tryon Street -located
approximately 150 feet southwest and topographically downgradient of the site.
According to the FirstSearch report,oil and grease contamination was detected
in the soil during redevelopment.The report indicates that the source is most
likely the former junkyard that occupied the property prior to redevelopment.
Based on groundwater flow direction inferred from surface topography, ECS
ECS Project No. 08-8606
November 01, 2012
-12 -
does not consider this facility to be an REC of the site.
·Acoustics, Inc., 3324 Pelton Street -located approximately 260 feet east and
topographically upgradient of the site.According to the FirstSearch report, this
facility formerly operated one 2,000-gallon gasoline UST.During the removal of
the UST, minor soil contamination was detected.A No Further Action (NFA) was
issued by the North Carolina Department of Environment and Natural Resources
(NCDENR) on May 13, 1993.Based on the NFA issued by NCDENR, ECS does
not consider this facility to be an REC of the site.
The FirstSearch report identified an additional property within the search distance of
inquiry. Based on the distance from the site and/or the presumed groundwater flow
direction inferred from surface topography, ECS does not consider this facility to be
RECs of the site.
Leaking Underground Storage Tank (LUST) List
The LUST list, maintained by NCDENR-Department of Waste Management (DWM), is a
record of reported leaking underground storage tank incidents. The LUST list may also
identify properties that have had soil and/or groundwater contamination associated with
documented releases from aboveground storage tanks, surface spills and other sources.
The site was not identified on the LUST list.
One or more off-site properties within the minimum search distance of inquiry were
reported as being on the LUST database.
·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing.
·Acoustics, Inc., 3324 Pelton Street -See IMD Listing.
·CATS Bus Maintenance & Operations Facility, 3251 South Tryon Street -
located approximately 120 feet north and topographically crossgradient to
downgradient of the site.According to the FirstSearch report, a release was
reported on December 23, 2009.Based on the groundwater flow direction
obtained from the monitoring wells located on-site, ECS does not consider this
facility to be an REC of the site.
The FirstSearch report identified an additional twenty properties within the search
distance of inquiry. Based on the distance from the site and/or the presumed
groundwater flow direction inferred from surface topography, ECS does not consider
these facilities to be RECs of the site.
Leaking Underground Storage Tanks (LUST TRUST)
The LUST TRUST, maintained by NCDENR-DWM, contains information about claims
against the State Trust Funds for reimbursements for expenses incurred while
remediating Leaking USTs.
The site was not identified on the Leaking Underground Storage Tank (LUST TRUST)
list.
ECS Project No. 08-8606
November 01, 2012
-13 -
No off-site properties within the minimum search distance of inquiry were reported as
being on the LUST TRUST database.
Old Landfill Inventory (OLI)
The OLI is maintained by the NCDENR. The inventory does not include no further action
sites and other agency lead sites.
The site was not identified on the OLI.
No off-site properties within the minimum search distance of inquiry were reported as
being on the OLI.
Registered Underground Storage Tank (UST) List
The Registered UST List inventories underground storage tanks registered with the
NCDENR, Division of Water Quality. This list does not identify USTs that have not been
registered with the NCDENR, such as home heating oil tanks and other unregulated
tanks.
The site was not identified on the Registered UST list.
One or more off-site properties within the minimum search distance of inquiry were
reported as being on the Registered UST list.
·Monarch Sprinkler, 308 Clanton Road -located on the adjoining property to the
south and across a creek.According to the FirstSearch report, this facility
formerly operated one 1,000-gallon gasoline UST.The UST was reportedly
closed on October 1, 1988.Based on groundwater flow direction inferred from
surface topography, ECS does not consider this facility to be an REC of the site.
·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing.
Solid Waste Facilities/Historic Landfill List (HIST LF)
State Historic Solid Waste Facility site records are maintained by the North Carolina
Department of Environment and Natural Resource.
The site was not identified on the HIST LF listing in the search report.
No off-site properties within the minimum search distance of inquiry were reported as
being on the HIST LF listing in the search report.
Solid Waste Facilities/Landfill(SWL) List
The North Carolina Solid Waste Section maintains a list of permitted solid waste
facilities. These facilities may be active or inactive facilities or open dumps that failed to
meet RCRA Subtitle D Section 4004 criteria for solid waste landfills or disposal sites.
The site was not identified on the North Carolina SWL.
No off-site properties within the minimum search distance of inquiry were reported as
being on the North Carolina SWL.
ECS Project No. 08-8606
November 01, 2012
-14 -
State Brownfield Projects Inventory
The State Brownfield Projects Inventory identifies brownfield projects inventoried with
the North Carolina Department of Environment and Natural Resources (NCDENR). The
properties in the inventory are working toward a brownfield agreement for cleanup and
liability control.
The site was not identified on the State Brownfield Projects Inventory.
One or more off-site properties within the minimum search distance of inquiry were
reported as being on the State Brownfield Projects Inventory.
·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing.
The FirstSearch report identified an additional five properties within the search distance
of inquiry. Based on the distance from the site and/or the presumed groundwater flow
direction inferred from surface topography, ECS does not consider these facilities to be
RECs of the site.
State EC List
The EC List identifies engineering controls including various forms of caps, building
foundations, liners, and treatment methods used to eliminate pathways for regulated
substances to enter environmental media or affect human health.
The site was not identified on the State EC List.
State Hazardous Substance Disposal Site (HSDS)
The State HSDS records are locations of uncontrolled and unregulated hazardous waste
sites. The records include sites on the NPL as well as those on the state priority list.
The site was not identified on the HSDS list.
No off-site properties within the minimum search distance of inquiry were reported as
being on the HSDS.
State Hazardous Waste Sites (SHWS) Inventory
State hazardous waste site records are the states’ equivalent to CERCLIS. These sites
may or may not be already listed on the federal CERCLIS database.
The site was not identified on the SHWS Inventory.
One or more off-site properties within the minimum search distance of inquiry were
reported as being on the SHWS Inventory.
·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing.
The FirstSearch report identified an additional seventeen properties within the search
distance of inquiry. Based on the distance from the site and/or the presumed
groundwater flow direction inferred from surface topography, ECS does not consider
these facilities to be RECs of the site.
ECS Project No. 08-8606
November 01, 2012
-15 -
State Institutional Control (IC) List
The State IC List identifies No Further Action facilities with land use restrictions
monitoring requirements.
The site was not identified on the State IC List.
State Responsible Party Voluntary Action (VCP) Sites
The VCP Sites is a listing of sites that parties wish to remediate voluntarily. The program
is administered by the NCDENR.
The site was not identified on the VCP Sites list.
One or more off-site properties within the minimum search distance of inquiry were
reported as being on the VCP Sites list.
·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing.
State Unmapped (Orphan) Facilities and Sites
Several properties were identified on the Orphan Summary List prepared by FirstSearch.
These facilities are considered by FirstSearch as unmappable because the facility
information in the database is insufficient and does not report accurate facility location
information.
The site was not identified on the Unmapped (Orphan) Facilities and Sites.
No off-site properties within the minimum search distance of inquiry were reported as
being on the Unmapped (Orphan) Facilities and Sites.
Drycleaners
The Drycleaners database identifies potential and known drycleaning sites, active and
abandoned.
The site was not identified on the Drycleaners database.
No off-site properties within the minimum search distance of inquiry were reported as
being on the Drycleaners database.
5.3 Historical Use Information
Sanborn Fire Insurance Map Review
Historic Fire Insurance Maps (i.e., Sanborns) were obtained from The University of North
Carolina at Chapel Hill, University Libraries Digital Collections (via the internet). ECS
reviewed maps from 1884 to 1910. According to the FirstSearch report, Sanborn maps
were available for the area; however, the subject site was not covered on the Sanborns.
ECS Project No. 08-8606
November 01, 2012
-16 -
Aerial Photograph Review
ECS reviewed aerial photographs of the site and immediately surrounding properties for
evidence of former usage which may constitute a potential for environmental concern.
The aerial photographs were obtained from the Mecklenburg County Natural Resource
Conservation Service, Mecklenburg County Geographic Information Systems (GIS)
Department and Google Earth. The aerial photographs reviewed were dated 1938, 1951,
1956, 1966, 1968, 1975, 1978, 1980, 1983, 1986, 1990, 1993, 1998, 2002, 2005 and
2010.Aerial photographs dated prior to 1938 were not available for review.
On the 1938 aerial photograph, the site appears to be cleared land.Surrounding
properties contain single family residences and cleared and wooded land.The site is
bounded to the west by South Tryon Street.South Boulevard is located to the east of
the site and Clanton Road is located south of the site.
On the 1951 aerial photograph, the site is wooded.Commercial development is located
to the east of the site along South Boulevard.Additional single family residences are
located to the south along South Tryon Street.
On the 1956 aerial photograph, the site is partially wooded.Commercial development is
located on the adjoining properties to the east and south of the site.Additional
commercial development is located to the north of the site.
On the 1966 and 1968 aerial photographs, the site appears to be cleared.Commercial
development is located to the east along Pelton Street and south of the site along
Clanton Road.A vehicle storage lot is located to the west of the site at the intersection
of South Tryon Street and Clanton Road.
On the 1975 aerial photograph, the site is partially wooded.Additional commercial
development is located to the west of the site and to the south of the site along Clanton
Road.
On the 1978 and 1980 aerial photographs, the site appears similar to the 1975 aerial
photograph.The vehicle storage lot to the west is cleared and vacant.
On the 1983, 1986 and 1990 aerial photographs, the site appears similar to the 1980
aerial photograph.Commercial development is located to the west of the site at the
intersection of South Tryon Street and Clanton Road.
On the 1993, 1998 and 2002 aerial photographs, the site is developed with a commercial
building consistent with the current facility. Surrounding areas appear similar to the 1990
aerial photograph.
On the 2005 aerial photograph, the site appears similar to the 2002 aerial photograph.
Commercial development consistent with the CATS bus facility is located to the north of
the site.
On the 2010 aerial photograph, the site and surrounding areas appear consistent with
conditions observed during the site reconnaissance.
ECS Project No. 08-8606
November 01, 2012
-17 -
ECS considers the lack of aerial photographs dated in excess of ten year intervals to be
a data failure (historical data gap).
City Directory Review
One of the ASTM standard historic sources to be reviewed for previous site use are local
street directories, commonly known as City Directories.The purpose of the directory
review is to identify past occupants of the site, adjoining properties, or nearby
properties.In some rural areas, street directories information is limited.
The Charlotte city directories dated 1940, 1945, 1950, 1955, 1959, 1967, 1971, 1975,
1980, 1984, 1992, 1995, 2000, 2005 and 2012 were obtained from the Mecklenburg
County Public Library. ECS reviewed listings for South Tryon Street, Clanton Road and
Pelton Street. The purpose of the city directory review is to identify past occupants of the
site and immediately surrounding properties.
Site Listings -The site is listed as Carolina Marking Devices, Inc. and Caromark Stamps
and Signs in the 2005 city directory. In the 2000, 1995 and 1992 city directories, the site
is listed as Carolina Marking Devices, Inc. The site is not listed in city directories dated
prior to 1992.
South Tryon Street -Listings included Jackson Roofing, Neal Properties, Charlotte Area
Transit Systems, Fast Signs, A Bedder Bedder, Carolina Concrete Pumping, Quality Dry
Cleaning (approximately 780 feet southwest and topographically downgradient), Fina Oil
Company (approximately 400 feet southwest and topographically downgradient) and
single family residences. The property located at 3419 South Tryon Street
(approximately 100 feet south and located across a creek) was listed as Bonded Oil
gasoline station in 1967, Professional Oil gasoline station in 1971, Adam’s Garage in
1975, H&M Auto from 1980 to 1990 and as Cecil’s Auto Repair from 1995 to 2005.
Based on the groundwater flow direction inferred from surface topography, ECS does
not consider this property to be an REC of the site.
Clanton Road -Listings included Hertron International, LLC (adjoining property to the
south and across a creek), Staff Zone, SFI Electronics, Scooter Store, FN Thompson
General Contractors, Lifespan Manufacturers, WB & Associate Inc of Charlotte, New
South Drywall Contracting, Automotive Parts Express Inc., Sid Harvey Hasko Inc,
Catawba Industrial Rubber Company, Superior Tile Marble and Terrazzo, Chain Belt
Company and Pelton & Crane Company. Pelton & Crane Company is located on the
adjoining property to the east and was listed from 1959 until 1992. Additional details
regarding this facility are discussed in Section 5.2.
Pelton Street -Listings included Triangle Fastener Corporation, Acoustics Incorporated,
Engineering Sales Associates, Edwards Enterprises-Carolina, Laufen International,
Threadline Products Incorporated, Pan Glo Charlotte, Tubelite Company Incorporated,
Middlebury Mouldings, and Exotic Pet Supply.
ECS considers the lack of city directories dated in excess of five year intervals to be a
data failure (historical data gap).
ECS Project No. 08-8606
November 01, 2012
-18 -
Other Standard Historical Sources
In accordance with the ASTM Standard, other historical sources should be reviewed, if
necessary and if the information is likely to be useful, to obtain historical site use
information. Other Standard Historical Sources may include property tax files, recorded
land title records, historic USGS topographic maps, building department records, and
zoning or land use records.
ECS obtained tax information regarding the subject site from Mecklenburg County tax
information via the internet. According to the tax information, the property is identified as
tax Parcel ID No. 14702131.The owner of the parcel is Solomon Shapiro.
Other Local Historical Sources
Other credible historical sources may be reviewed to identify past uses of the property.
These sources may include internet sites, county or State road maps, historical society
documents, or local library information.
ECS obtained tax information about the site from the Mecklenburg County GIS
department (via the internet).
ECS obtained city directories from the Mecklenburg County Public Library as discussed
in the City Directories section in Section 5.4.
Freedom of Information (FOIA)Requests
ECS contacted Mr. Garry McCormick, Hazardous Material Coordinator with the Charlotte
Mecklenburg County Fire Department regarding reported incidents of spills and
environmental issues associated with the site and surrounding area. At the time of this
report, ECS has not received a response from the Charlotte Mecklenburg Fire
Department. ECS considers the lack of fire department information to be a data gap. An
addendum will be issued if ECS receives a response at a later date that indicates a
material difference in ECS’s findings.
ECS Project No. 08-8606
November 01, 2012
-19 -
6.0 SITE AND AREA RECONNAISSANCE
6.1 Methodology and Limiting Conditions
Mr. David E. Valentine of ECS conducted the field reconnaissance on October 10, 2012.
The weather at the time of the reconnaissance was approximately 60 degrees
Fahrenheit and sunny. Observations were made from a walking reconnaissance around
the perimeter boundary and several transects through the site and building.
Photographs, taken at the time of the site reconnaissance, are included in Appendix V.
6.2 On-Site Features
The site is an approximate 3.03 acre tract located at 3405 South Tryon Street in
Charlotte, Mecklenburg County, North Carolina.The site is developed with an
approximate 24,000 square foot, one-story commercial warehouse.The building was
constructed in 1991 and was formerly occupied by Carolina Marking Devices, Inc.The
site was used for production of marking devices (stamps, badges, notary seals, etc.) that
utilized various inks.The building contains a showroom, offices, a production area and a
warehouse.The remainder of the site consists of an asphalt paved parking lot and
landscaped areas.The site is provided water and sanitary sewer services through the
Charlotte Mecklenburg Utilities Department.The site is provided natural gas through
Piedmont Natural Gas.
Underground or aboveground storage tanks
We did not observe aboveground storage tanks or evidence of underground storage
tanks at the site.
Strong, pungent or noxious odors
We did not notice strong, pungent or noxious odors at the site.
Surface waters
The following observations were made with regard to surface waters on the site:
ECS observed a creek along the southern site boundary.Sheens, indicative of
petroleum byproducts, was not observed on the surface of the water.
Standing pools of liquid likely containing petroleum or hazardous substances
We did not observe standing pools of liquid at the site.
Drums or containers of petroleum or hazardous substances greater than five-
gallons
We did not observe drums or containers of petroleum or hazardous substances greater
than five-gallons at the site.
Drums or containers of petroleum or hazardous substances less than or equal to
five-gallons
The following observations were made with regard to drums or containers of petroleum
ECS Project No. 08-8606
November 01, 2012
-20 -
or hazardous substances less than or equal to five-gallons at the site:
ECS observed various paint containers located in the warehouse.There was no visual
evidence that the containers had leaked or the material had been spilled.
Unidentified opened or damaged containers of hazardous substances or
petroleum products
We did not observe unidentified opened or damaged containers of hazardous
substances or petroleum products at the site.
Known or suspect PCB-containing equipment (excluding light ballasts)
The following observations were made with regard to known or suspect PCB-containing
equipment on the site:
ECS observed one pad mounted transformer located on-site.The transformer is owned
and maintained by Duke Energy.Staining was not observed on the ground surface in
the vicinity of the transformer.
Stains or corrosion to floors, walls or ceilings
The following observations were made with regard to stains or corrosion to floors, walls
or ceilings:
ECS observed two air compressors in the building that were leaking oil.The oil
appeared to have traveled into cracks in the concrete flooring.ECS considers the oil
from the air compressors to be an REC of the site.
ECS observed staining on the concrete in the ink storage room.The concrete appeared
to be in good condition.
Floor drains and sump pumps
The following observations were made with regard to floor drains or sump pumps at the
site:
ECS observed a floor drain in the production area of the building.A wash basin is
located next to the drain with a pipe running into the drain.The facility was not listed in
the regulatory database as having a wastewater discharge permit and was not listed as
having records of incidents.
Pits, ponds or lagoons
We did not observe pits, ponds or lagoons at the site.
Stained soil or pavement
We did not observe stained soils or pavement at the site.
Stressed vegetation
We did not observe stressed vegetation at the site.
Solid waste mounds or non-natural fill materials
We did not observe solid waste mounds or non-natural fill materials at the site.
ECS Project No. 08-8606
November 01, 2012
-21 -
Wastewater discharges into drains, ditches or streams
We did not observe wastewater discharges at the site.
Groundwater wells including potable, monitoring, dry, irrigation, injection and/or
abandoned
The following observations were made with regard to groundwater wells at the site:
ECS observed five groundwater monitoring wells located on the site.The monitoring
wells are associated with on-going remediation activities from the former Pelton & Crane
facility as discussed in Section 5.2.ECS considers these monitoring wells to be RECs
of the site.
Septic systems or cesspools
We did not observe evidence of septic systems or cesspools on the site.
Elevators
We did not observe elevators on the site.
Dry Cleaning
We did not observe dry-cleaning operations on the site.
Onsite Emergency Electrical Generators
We did not observe emergency generators on the site.
6.3 Adjoining and Nearby Properties
Contiguous and nearby properties were observed during a walking and vehicular
reconnaissance of the property boundary and public places.The site is located in a
commercial/residential area of Charlotte, North Carolina.
The site is bounded on the north by CATS bus facility with additional commercial
development located further north.
The site is bounded on the east by goodmortgage.com and Lifespan with additional
commercial buildings and single family residences located further east.
The site is bounded on the south by USTT, Hertron, Staffzone and C.A.R.S. with
additional commercial development located further south.
The site is bounded on the west by South Tryon Street, 77 Corporate Park and Fast
Signs with additional commercial buildings and single family development located further
west.
ECS Project No. 08-8606
November 01, 2012
-22 -
7.0 ADDITIONAL SERVICES
7.1 Non-Scope Issues
ASTM guidelines identify non-scope issues, which are beyond the scope of this practice.
Non-scope issues have the potential to be business environmental risks. Some of these
non-scope issues include; asbestos-containing building materials, radon, lead-based
paint, lead in drinking water, wetlands and mold.
We were not authorized to conduct non-scope services for the site.
7.2 Previous Reports Review
We have conducted the following environmental and/or engineering assessment(s) for
the site:
ECS conducted a Property Condition Assessment for the subject site. Findings from the
report are included under a separate cover, ECS Project No. 08-8606A, dated October
2012.
We have not been provided with environmental or engineering assessment reports for
the site completed by others.
ECS Project No. 08-8606
November 01, 2012
-23 -
8.0 INTERVIEWS
ECS spoke with Mr. Greg Pappanastos, President of Argos Real Estate Advisors and
representative of the owner of the site.Mr. Pappanastos indicated that the site was
formerly occupied with Carolina Marking Devices, Inc.Mr. Pappanastos indicated that
the former tenant had occupied the site from 1991 to 2012.Mr. Pappanastos indicated
that he is unaware of past operations on the site that would be considered an
environmental concern for the site.Mr. Pappanastos indicated that the former Pelton &
Crate Company facility (adjoining property to the east) was currently undergoing
remediation activities and that contamination from the facility had been detected on the
subject site.Mr. Pappanastos provided ECS with regulatory documents related to the
remediation activities.Mr. Pappanastos indicated that he is unaware of USTs or
environmental concerns associated with the subject site.
ECS attempted to contact the Charlotte Mecklenburg Utilities Department regarding the
subject site.At the time of this report, ECS has not recieved a response deom the
Charlotte Mecklenburg Utilities Department.An addendum will be issued if ECS
receives a response at a later date that indicates a material difference in ECS’ findings.
ECS contacted Mr. Garry McCormick, Hazardous Material Coordinator with the Charlotte
Mecklenburg County Fire Department regarding reported incidents of spills and
environmental issues associated with the site and surrounding area. At the time of this
report, ECS has not received a response from the Charlotte Mecklenburg Fire
Department. ECS considers the lack of fire department information to be a data gap. An
addendum will be issued if ECS receives a response at a later date that indicates a
material difference in ECS’ findings.
ECS Project No. 08-8606
November 01, 2012
-24 -
9.0 FINDINGS
The site is an approximate 3.03 acre tract located at 3405 South Tryon Street in
Charlotte, Mecklenburg County, North Carolina.The site is developed with an
approximate 24,000 square foot, one-story commercial warehouse.The building was
constructed in 1991 and was formerly occupied by Carolina Marking Devices, Inc.The
site was used for production of marking devices (stamps, badges, notary seals, etc.) that
utilized various inks.The building contains a showroom, offices, a production area and a
warehouse.The remainder of the site consists of an asphalt paved parking lot and
landscaped areas.The site is provided water and sanitary sewer services through the
Charlotte Mecklenburg Utilities Department.The site is provided natural gas through
Piedmont Natural Gas.ECS did not observe USTs associated with the site.
ECS observed two air compressors in the building that were leaking oil.The oil
appeared to have traveled into cracks in the concrete flooring.ECS considers the oil
from the air compressors to be an REC of the site.
ECS observed five groundwater monitoring wells located on the site.The monitoring
wells are associated with on-going remediation activities from the former Pelton & Crane
facility as discussed in Section 5.2.ECS considers these monitoring wells to be RECs
of the site.
ECS reviewed historical aerial photographs and city directories for the subject site and
surrounding areas.The aerial photograph review depicted the site to be historically
undeveloped until the current facility was constructed in 1991.Surrounding properties
were historically developed with residential and commercial structures.The site is listed
as Carolina Marking Devices, Inc. and Caromark Stamps and Signs in the 2005 city
directory. In the 2000, 1995 and 1992 city directories, the site is listed as Carolina
Marking Devices, Inc. The site is not listed prior to the 1992 city directories.The site is
currently bounded on the north by CATS bus facility; on the east by goodmortgage.com
and Lifespan; on the south by USTT, Hertron, Staffzone and C.A.R.S.; and, on the west
by South Tryon Street, 77 Corporate Park and Fast Signs.
The site is located in a commercial/residential area of Charlotte, North Carolina. A
regulatory records search report, dated October 8, 2012 of ASTM standard and
supplemental databases was prepared for the site by FirstSearch. FirstSearch identified
multiple properties within the search distance of inquiry and one to be of environmental
concern with respect to the site:
·Pelton & Crane Plant (Former), 200 Clanton Road -located on the adjoining
property to the east and topographically upgradient of the site.According to the
FirstSearch report, this facility formerly operated one 2,000-gallon oil UST and
one 650-gallon oil UST.ECS reviewed regulatory files regarding this facility.
During the removal of the USTs soil and groundwater contamination were
identified.The contaminants identified included metals, chlorinated organic
solvents and polyaromatic hydrocarbons.Contamination was discovered on the
subject site (3405 South Tryon Street) along the eastern site boundary and in the
creek bed.Soil remediation was completed in 2008. Groundwater source
ECS Project No. 08-8606
November 01, 2012
-25 -
treatment has been conducted since 2005.Monitoring wells located on the
subject site indicate elevated groundwater contaminants.The monitoring wells
indicated that the groundwater flows radially from the facility towards the
southwest, west and northwest.Additional remediation activities are planned for
2013.In October 2012,deep soil gas samples were collected on the subject site
to evaluate the potential for vapor intrusion. The samples collected were below
the state's industrial/commercial vapor intrusion levels.Based on contamination
being identified on-site, ECS considers the release associated with this off-site
facility to be an REC of the site.
ECS Project No. 08-8606
November 01, 2012
-26 -
10.0 CONCLUSIONS AND OPINIONS
ECS has performed a Phase I Environmental Site Assessment in conformance with the
scope and limitations of ASTM Practice E 1527-05 of the site located at 3405 South
Tryon Street in Charlotte, Mecklenburg County, North Carolina.Any exceptions to, or
deletions from, this practice are described in Section 2.3 of this report.
As documented and qualified by this report, this assessment has revealed the following
evidence of RECs in connection with the property:
On-Site:
Potential exists that the discharge oil from the air compressors could impact soil and/or
groundwater beneath the site.ECS recommends additional assessment to determine if
soil and/or groundwater beneath the site has been impacted.
ECS observed five groundwater monitoring wells on-site that are associated with on-
going remediation activities at the former Pelton & Crane facility located on the adjoining
property to the east.
Off-Site:
The former Pelton & Crane facility located on the adjoining property to the east is
currently undergoing remediation activities.ECS recommends that the responsible party
continue with remediation activities for the former Pelton & Crane facility.ECS also
recommends requesting and periodically reviewing sampling and reporting conducted by
the responsible party and having a qualified environmental professional review the
findings.
ECS Project No. 08-8606
November 01, 2012
-27 -
11.0 REFERENCES
Mecklenburg County NRCS Department, Aerial Photographs dated 1938, 1951, 1956,
1968 and 1983.
Mecklenburg County GIS Department, Aerial Photographs dated 1966, 1975, 1978,
1980, 1983, 1986, 1990 and 1997.
Google Earth, Aerial Photographs dated 1993, 1998, 2002, 2005 and 2010.
Mecklenburg County City Directories, dated 1940, 1945, 1950, 1955, 1959, 1967, 1971,
1975, 1980, 1984, 1992, 1995, 2000, 2005 and 2012.
FirstSearch Report dated October 8, 2012.
Geologic Map of North Carolina, compiled by the North Carolina Geological Society,
dated 1985.
USGS Topographic Map, Charlotte West, North Carolina Quadrangle Dated 1993.
USGS Topographic Map, Charlotte East, North Carolina Quadrangle Dated 1967.
APPENDIX I
FIGURES
FIGURE 1
SITE LOCATION MAP
Carolina Marking Devices, Inc.
3405 South Tryon St.
Charlotte, Mecklenburg County, North Carolina
ECS Project No. 08-8606
SOURCE:
USGS TOPOGRAPHIC MAP:
Charlotte West, Dated 1993
Charlotte East, Dated 1967
North Carolina Quadrangles
Scale: 1” ~ 2,000’
SITE
LEGEND
1 – Unity Auto Sales
2 – CATS Bus Facility
3 – Goodmortgage.com
4 – Lifespan (Former Pelton & Crane Co.)
5 – Engineering Sales Associates
6 – AEC
7 – USTT
8 – Hertron
– Monitoring Well – LUST Incident
SOURCE:
Google Earth
(via the Internet)
Scale as Shown
FIGURE 2
2010 AERIAL PHOTOGRAPH
Carolina Marking Devices, Inc.
3405 South Tryon Street
Charlotte, Mecklenburg County, North Carolina
ECS Project No. 08-8606
2
4
1
315 5
6
7
8
9
16
11
10
12
13
14
9 – Staff Zone
10 – C.A.R.S
11 – Heineman
12 – Carolina Wood Flooring
13 – Retail Center
14 – Carolina Auto House
15 – 77 Corporate Park
16 – Fast Signs
APPENDIX II
CORRESPONDENCE AND USER QUESTIONNAIRE
APPENDIX III
REGULATORY RECORDS DOCUMENTATION
ENVIRONMENTAL FIRSTSEARCH REPORT
TARGET PROPERTY:
3405 SOUTH TRYON ST.
3405 S TRYON ST
CHARLOTTE, NC 28217
JOB NUMBER: 8606
PREPARED FOR:
ECS Carolinas, LLP
1812 Center Park Drive, Suite D
Charlotte, NC 28217
October 8, 2012
Environmental FirstSearch
Search Summary Report
Target Site:3405 S TRYON ST
CHARLOTTE, NC 28217
FirstSearch Summary
Notice of Disclaimer
Waiver of Liability
Database Sel Updated Radius Site 1/8 1/4 1/2 1/2> ZIP TOTALS
NPL Y 09-20-12 1.00 0 0 0 0 0 0 0
NPL Delisted Y 09-20-12 0.50 0 0 0 0 -0 0
CERCLIS Y 08-01-12 0.50 0 0 0 0 -1 1
NFRAP Y 08-01-12 0.50 0 0 0 4 -1 5
RCRA COR ACT Y 09-11-12 1.00 0 0 0 0 0 0 0
RCRA TSD Y 09-11-12 0.50 0 0 0 0 -0 0
RCRA GEN Y 09-11-12 0.25 0 0 5 --0 5
Federal Brownfield Y 07-15-12 0.50 0 0 0 2 -0 2
ERNS Y 10-04-12 0.12 0 0 ---1 1
Tribal Lands Y 12-15-08 1.00 0 0 0 0 0 1 1
State/Tribal Sites Y 06-08-12 1.00 0 1 1 8 9 1 20
State Spills 90 Y 06-01-12 0.12 0 4 ---0 4
State Spills 80 Y 06-14-01 0.25 0 0 1 --0 1
State/Tribal SWL Y 05-26-11 0.50 0 0 0 0 -8 8
State/Tribal LUST Y 06-01-12 0.50 0 4 3 20 -4 31
State/Tribal UST/AST Y 06-01-12 0.25 0 7 9 --0 16
State/Tribal EC Y NA 0.50 0 0 0 0 -0 0
State/Tribal IC Y 06-08-12 0.25 0 0 0 --0 0
State/Tribal VCP Y 07-30-07 0.50 0 1 0 0 -0 1
State/Tribal Brownfields Y 08-10-12 0.50 0 3 0 6 -1 10
State Other Y 06-24-10 0.25 0 0 0 --0 0
Federal IC/EC Y 09-18-12 0.50 0 0 0 0 -0 0
Dry Cleaners Y 05-21-12 0.25 0 0 0 --0 0
-TOTALS-0 20 19 40 9 18 106
Due to the limitations, constraints, and inaccuracies and incompleteness of government information and computer mapping data currently available to FirstSearch
Technology Corp., certain conventions have been utilized in preparing the locations of all federal, state and local agency sites residing in FirstSearch Technology Corp.'s
databases. All EPA NPL and state landfill sites are depicted by a rectangle approximating their location and size. The boundaries of the rectangles represent the eastern
and western most longitudes; the northern and southern most latitudes. As such, the mapped areas may exceed the actual areas and do not represent the actual
boundaries of these properties. All other sites are depicted by a point representing their approximate address location and make no attempt to represent the actual
areas of the associated property. Actual boundaries and locations of individual properties can be found in the files residing at the agency responsible for such
information.
Although FirstSearch Technology Corp. uses its best efforts to research the actual location of each site, FirstSearch Technology Corp. does not and can not warrant the
accuracy of these sites with regard to exact location and size. All authorized users of FirstSearch Technology Corp.'s services proceeding are signifying an understanding
of FirstSeaarch Technology Corp.'s searching and mapping conventions, and agree to waive any and all liability claims associated with search and map results showing
incomplete and or inaccurate site locations.
Environmental FirstSearch
Site Information Report
Request Date:10-08-12 Search Type:COORD
Requestor Name:Louise Bhavnani Job Number:8606
Standard:AAI Filtered Report
Target Site:3405 S TRYON ST
CHARLOTTE, NC 28217
Demographics
Sites:106 Non-Geocoded:18 Population:NA
Radon:NA
Fire Insurance Map Coverage:Yes
Site Location
Degrees (Decimal) Degrees (Min/Sec) UTMs
Longitude:-80.875927 -80:52:33 Easting:511294.955
Latitude:35.196858 35:11:49 Northing:3894683.119
Elevation:721 Zone:17
Comment
Comment:
Additional Requests/Services
Adjacent ZIP Codes:Services:
ZIP
Code City Name ST Dist/Dir Sel Requested? Date
Fire Insurance Maps No
Aerial Photographs No
Historical Topos No
City Directories No
Title Search No
Municipal Reports No
Liens No
Historic Map Works No
Online Topos No
Environmental FirstSearch
Target Site Summary Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0
No sites found for target address
Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No.
Environmental FirstSearch
Sites Summary Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0
Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No.
1 UST MONARCH SPRINKLER 308 CLANTON RD 0.08 SW - 1 1
0-014170/PERM CLOSED REMOVED CHARLOTTE NC 28210
2 STATE PELTON & CRANE PLANT (FORMER)200 CLANTON RD 0.10 SE + 30 2
NCD055162069/ACTIVE CHARLOTTE NC
2 SPILLS CLANTON ROAD FACILITY 200 CLANTON RD 0.10 SE + 30 3
15846/CLOSED OUT CHARLOTTE NC
2 SPILLS PELTON & CRANE PLANT (FORMER,200 CLANTON RD 0.10 SE + 30 4
85670/NOD CHARLOTTE NC
2 UST CLANTON ROAD FACILITY 200 CLANTON RD 0.10 SE + 30 5
MO-4766/CHARLOTTE NC 28217
2 UST THE PELTON & CRANE CO.200 CLANTON RD 0.10 SE + 30 7
0-014524/PERM CLOSED REMOVED CHARLOTTE NC 28210
2 LUST CLANTON ROAD FACILITY 200 CLANTON RD 0.10 SE + 30 10
NCI-015846/CLOSED OUT CHARLOTTE NC 28217
2 LUST PELTON & CRANE PLANT (FORMER)200 CLANTON RD 0.10 SE + 30 11
NCI-085670/NOD CHARLOTTE NC
2 BROWNFIE FORMER PELTON & CRANEPLANT 200 CLANTON RD 0.10 SE + 30 12
NCBR-0206-047/ACTIVE CHARLOTTE NC
2 BROWNFIE PELTON & CRANE PLANT 200 CLANTON RD 0.10 SE + 30 13
NCBR-1106-033/FINALIZED CHARLOTTE NC
2 BROWNFIE PELTON AND CRANE PLANT - FORMER 200 CLANTON RD 0.10 SE + 30 14
09034-05-60/FINALIZED CHARLOTTE NC
2 VCP PELTON & CRANE PLANT (FORMER)200 CLANTON RD 0.10 SE + 30 15
VC-NCD055162069/VOLUNTARY CLEANUP CHARLOTTE NC
3 SPILLS 77 CORPORATE PARK CLANTON ROAD, SOUTH TRYON 0.10 SW + 3 16
86378/CURRENT RECORD CHARLOTTE NC 28217
4 SPILLS ACOUSTICS, INC.3324 PALTON ST 0.11 SE + 37 17
10174/CLOSED OUT CHARLOTTE NC
4 UST ACOUSTICS INCORPORATED 3324 PELTON ST 0.11 SE + 37 18
0-026559/PERM CLOSED REMOVED CHARLOTTE NC 28217
4 UST ACOUSTICS, INC.3324 PELTON ST 0.11 SE + 37 21
MO-3782/CHARLOTTE NC 28217
4 LUST ACOUSTICS, INC.3324 PALTON ST 0.11 SE + 37 23
NCI-010174/CLOSED OUT CHARLOTTE NC 28217
5 UST CATS BUS M AND O 3251 S TRYON ST 0.12 NE + 3 24
0-03679/UNKNOWN CHARLOTTE NC 28217
5 UST CATS BUS MAINTENANCE AND OPS FAC 3251 S TRYON ST 0.12 NE + 3 26
0-036729/CURRENTLY OPERATIONAL CHARLOTTE NC 28217
5 LUST CATS BUS M AND O 3251 S TRYON ST 0.12 NE + 3 29
NCI-036749/CURRENT RECORD CHARLOTTE NC 28217
Environmental FirstSearch
Sites Summary Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0
Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No.
6 UST JOE B. WILLIAMS PROPERTY 3500 S TRYON ST 0.13 SW + 9 30
MO-4083/UNKNOWN CHARLOTTE NC 28217
6 LUST JOE B. WILLIAMS PROPERTY 3500 S STRYON ST 0.13 SW + 9 32
NCI-012153/CLOSED OUT CHARLOTTE NC 28217
7 UST 3206 SOUTH TRYON 3206 S TRYON ST 0.13 NE - 19 33
MO-2336/UNKNOWN CHARLOTTE NC 28217
8 RCRAGN ALTEC INDUSTRIES, INC 3335 PELTON ST 0.18 SE + 46 35
NCD986232510/SGN CHALOTTE NC 28220
9 UST BARCLAYS CAPITAL 3417 TRADE PARK CT 0.18 NW - 5 36
MO-180/CHARLOTTE NC 28217
9 UST BARCLAYS CAPITAL 3417 TRADE PARK CT 0.18 NW - 5 38
MO-0180/UNKNOWN CHARLOTTE NC 28217
9 UST BARCLAYS CAPITAL, INC.3417 TRADE PARK CT 0.18 NW - 5 40
0-035914/PERM CLOSED REMOVED CHARLOTTE NC 28217
10 RCRAGN CATS-BOD S TRYON BUS GARAGE 3145 S TRYON ST 0.19 NE - 4 41
NC0991302662/VGN CHARLOTTE NC 28202
11 RCRAGN PROVIDENCE PAINT CO 428 BLAIRHILL RD 0.19 SW + 6 43
NCR000143172/SGN CHARLOTTE NC 28217
12 RCRAGN PURE CLEAN 3601 S TRYON ST 0.20 SW + 6 45
NCD982163180/SGN CHARLOTTE NC 28205
13 STATE AMERICAN FENCE SOLVENTS 3605 S TRYON ST 0.20 SW + 5 46
NONCD0001255/ACTIVE CHARLOTTE NC
13 UST AMERICAN FENCE 3605 S TRYON ST 0.20 SW + 5 47
MO-7007/UNKNOWN CHARLOTTE NC 28217
13 LUST AMERICAN FENCE 3605 S TRYON ST 0.20 SW + 5 49
NCI-027713/CLOSED OUT CHARLOTTE NC 28217
14 RCRAGN ARTS ENGRAVING CO INC 3136 MAY ST 0.21 NW - 39 50
NCD003151701/VGN CHARLOTTE NC 28217
15 SPILLS80 CANTEEN CO.3621 TRYCLAN RD 0.22 SW + 4 52
6923/RESPONSE CHARLOTTE NC
15 LUST CANTEEN FOOD SERVICES 3621 TRYCLAN RD 0.22 SW + 4 53
NCI-006923/RESPONSE CHARLOTTE NC 28217
16 UST CANTEEN CORPORATION 3631 TRYCLAN DR 0.22 SW + 3 54
0-014703/PERM CLOSED REMOVED CHARLOTTE NC 28210
16 UST CANTEEN FOOD SERVICES 3631 TRYCLAN DR 0.22 SW + 3 55
MO-3117/UNKNOWN CHARLOTTE NC 28217
17 UST F N THOMPSON INC 201 CLANTON RD 0.22 SE + 30 57
0-002592/PERM CLOSED REMOVED CHARLOTTE NC 28232
18 LUST CATS MAINTENANCE FACITLITY 3200 SOUTH BLVD 0.27 SE + 41 60
NCI-027904/CLOSED OUT CHARLOTTE NC 28209
Environmental FirstSearch
Sites Summary Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0
Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No.
19 STATE CITY OF CHARLOTTE-SCALEYBARK SITE 3610 SOUTH BLVD 0.30 SE + 34 61
NONCD0002805/ACTIVE CHARLOTTE NC
20 LUST CONOCO STORE #33066 605 CLANTON RD 0.30 NW 0 62
NCI-011918/CLOSED OUT CHARLOTTE NC 28217
21 LUST PEPSI-COLA 3101 GRIFFITH ST 0.33 NE + 29 63
NCI-009747/CLOSED OUT CHARLOTTE NC 28203
22 LUST SERVCO #01613 3040 SOUTH BLVD 0.33 NE + 30 64
NCI-027648/CURRENT RECORD CHARLOTTE NC 28209
22 LUST SERVCO STATION/S. BLVD 3040 SOUTH BLVD 0.33 NE + 30 65
NCI-008796/CLOSED OUT CHARLOTTE NC 28209
23 NFRAP WILLIARD SMELTING CO.101 NEW BERN ST 0.35 NE + 35 66
NCD003151651/NFRAP-N CHARLOTTE NC 28203
23 STATE WILLARD SMELTING CO.101 NEW BERN ST 0.35 NE + 35 67
NCD003151651/ACTIVE CHARLOTTE NC
23 LUST WILLARD INDUSTRIES (FORMER)101 NEW BERN ST 0.35 NE + 35 68
NCI-017690/CLOSED OUT CHARLOTTE NC 28203
23 LUST WILLARD SMELTING CO 101 NEW BERN ST 0.35 NE + 35 69
NCI-085678/NOD CHARLOTTE NC
23 BROWNFIE WILLARD LEAD FACILITY 101 NEW BERN ST 0.35 NE + 35 70
NCBR-0206-087/FINALIZED CHARLOTTE NC
24 NFRAP BORDEN CHEMICAL PRINTING INK 3013 GRIFFITH ST 0.36 NE + 31 71
NCD049774375/NFRAP-N CHARLOTTE NC 28203
24 STATE BORDEN CHEMICAL PRINTING INK 3013 GRIFFITH ST 0.36 NE + 31 72
NCD049774375/NFA CHARLOTTE NC
25 NFRAP PIEDMONT HEAT TREATING CORP 3311 GRIFFITH ST 0.36 NE + 6 73
NCD066309113/NFRAP-N CHARLOTTE NC 28203
25 STATE PIEDMONT HEAT TREATING CORP 3311 GRIFFITH ST 0.36 NE + 6 74
NCD066309113/NFA CHARLOTTE NC
26 LUST EPMORE INC.2941 S TRYON ST 0.37 NE + 17 75
NCI-015304/RESPONSE CHARLOTTE NC 28203
27 BROWNFIE RUSAK PROPERTY 3004 BANK ST 0.38 NE + 5 76
NCBR-0038/FINALIZED CHARLOTTE NC
28 STATE NIVENS PROPERTY 3022 GRIFFITH ST 0.38 NE + 38 77
NONCD0002204/ACTIVE CHARLOTTE NC
28 LUST FLOORING CONCEPTS 3022 GRIFFITH ST 0.38 NE + 38 78
NCI-027262/CLOSED OUT CHARLOTTE NC 28203
29 BROWNFIE RUSAK PROPERTY 3331 GRIFFITH ST 0.38 NE - 10 79
NCBF-0811-003/FINALIZED CHARLOTTE NC
30 LUST MRS. J. SPENCER BELL/WF (RP-D)111 NEW BERN ST 0.40 NE + 39 80
NCI-005176/RESPONSE CHARLOTTE NC 28203
Environmental FirstSearch
Sites Summary Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0
Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No.
31 BROWNFIE BROWN S SOLVENT CO 2935 GRIFFITH ST 0.40 NE + 34 81
NCBR-0010/FINALIZED CHARLOTTE NC
31 BROWNFIE BROWN S SOLVENT CO.2935 GRIFFITH ST 0.40 NE + 34 82
05006-01-60/FINALIZED CHARLOTTE NC
31 FEDBROWN BROWN S SOLVENT COMPANY 2935 GRIFFITH ST 0.40 NE + 34 83
55781569-16/EPA BROWNFIELD CHARLOTTE NC
31 FEDBROWN BROWN S SOLVENT COMPANY 2935 GRIFFITH ST 0.40 NE + 34 85
13562/EPA BROWNFIELD CHARLOTTE NC 28203
32 BROWNFIE WILLARD LEAD RIGHT-OF-WAY 122 NEW BERN ST 0.40 NE + 38 87
15014-11-60/FINALIZED CHARLOTTE NC
33 LUST DIXIE WRECKER 3801 SOUTH BLVD 0.42 SE + 31 88
NCI-036241/CURRENT RECORD CHARLOTTE NC 28217
34 NFRAP SWIFT ADHESIVES & COATINGS 2917 YOUNGBLOOD ST 0.43 NE + 41 89
NCD980557763/NFRAP-N CHARLOTTE NC 28203
34 STATE SWIFT ADHESIVES & COATINGS/CHARLOT 2917 YOUNGBLOOD ST 0.43 NE + 41 90
NCD980557763/NFA CHARLOTTE NC
35 STATE TERRELL MACHINE SHOP 3000 SOUTH BLVD 0.43 NE + 27 91
NONCD0000011/ACTIVE CHARLOTTE NC
35 LUST TERRELL MACHINE COMPANY 0 P. O. BOX 240868 0.43 NE + 27 92
NCI-005015/RESPONSE CHARLOTTE NC
36 LUST SUMMERFIELD S AUTO 3017 SOUTH 0.43 NE + 33 93
NCI-005261/RESPONSE CHARLOTTE NC 28209
37 STATE CHARLOTTE BATTERY 2926 YOUNGBLOOD ST 0.44 NE + 34 94
NONCD0001150/ACTIVE CHARLOTTE NC
38 LUST C.M. ALLEN CONSTUCTION 3813 SOUTH BLVD 0.45 SE + 33 95
NCI-008582/RESPONSE CHARLOTTE NC 28209
39 LUST MEJIA AUTOMOTIVE PROPERTY 3821 SOUTH BLVD 0.47 SE + 29 96
NCI-036617/ARCHIVED CHARLOTTE NC 28209
40 LUST KRISPY KREME DOUGHNUT 2901 SOUTH BLVD 0.48 NE + 28 97
NCI-027265/CLOSED OUT CHARLOTTE NC 28217
41 LUST THE APPLE BUILDING 3809 WEONA AVE 0.48 SE + 31 98
NCI-010926/RESPONSE CHARLOTTE NC 28209
42 LUST PEPSI BOTTLING COMPANY 2820 SOUTH BLVD 0.50 NE + 48 99
NCI-027982/CLOSED OUT CHARLOTTE NC 28224
42 LUST PEPSI COLA BOTTLING COMPANY 2820 SOUTH BLVD 0.50 NE + 48 100
NCI-027939/CHARLOTTE NC 28209
43 LUST ROBERT MAHONEY RESIDENCE 3326 ANSON ST 0.50 SE - 5 101
NCI-009125/CLOSED OUT CHARLOTTE NC 28209
44 STATE MITCHELLS FORMAL WEAR (AFTER HOURS 115 SCALEYBARK RD 0.53 SE + 44 102
NONCD0002084/ACTIVE CHARLOTTE NC
Environmental FirstSearch
Sites Summary Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0
Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No.
45 STATE NCDOT ASPHALT SITE #57 - REA CONST 2701 YOUNGBLOOD CT 0.62 NE + 29 103
NONCD0002172/ACTIVE CHARLOTTE NC
45 STATE SUTTON PARK GROCERY 2701 YOUNGBLOOD ST 0.62 NE + 29 104
NONCD0002380/ACTIVE MONROE NC
46 STATE BALDOR ELECTRIC COMPANY 3821 BARRINGER RD 0.62 SW - 20 105
NONCD0001132/ACTIVE CHARLOTTE NC
47 STATE MECKLENBURG CO. OIL SPILL BASIN CR 626 MILLER ST 0.67 NE - 17 106
NCD986189983/NFA CHARLOTTE NC
48 STATE QUALEX 2519 DISTRIBUTION ST 0.75 NE + 44 107
NONCD0002348/ACTIVE CHARLOTTE NC
49 STATE AIR LIQUIDE 2414 SOUTH BLVD 0.81 NE + 42 108
NONCD0001231/ACTIVE CHARLOTTE NC
50 STATE TACO BELL #2 2405 SOUTH BLVD 0.87 NE + 49 109
NONCD0002573/ACTIVE CHARLOTTE NC
51 STATE SOUTHSIDE INVESTMENTS LLC 2222 SOUTH BLVD 1.00 NE + 56 110
NONCD0001076/ACTIVE CHARLOTTE NC
Environmental FirstSearch
Sites Summary Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0
Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No.
CERCLIS STEWART CREEK UNKNOWN NON GC N/A N/A
NCN000410138/NOT PROPOSED CHARLOTTE NC
NFRAP CSX DERAILMENT UNKNOWN NON GC N/A N/A
NCN000407318/NFRAP-N CHARLOTTE NC
ERNS NORTH TRYON ST NORTH TRYON ST NON GC N/A N/A
NRC-971718/FIXED CHARLOTTE NC
STATE UNITED METAL FINISHING RIDGE LANE RD NON GC N/A N/A
NONCD0002871/ACTIVE GREEENSBORO NC
SWL BICKEL DEMOLITION LANDFILL SHOPTON ROAD NON GC N/A N/A
60AD/INACTIVECLOSED CHARLOTTE NC
SWL DON MISENHEIMER RUBBLE SITE ALBEMARLE RT 1 NON GC N/A N/A
P0292/INACTIVECLOSED CHARLOTTE NC
SWL DON R ROBERTSON DEMO LANDFILL SHOPTON ROAD NON GC N/A N/A
60C/INACTIVECLOSED CHARLOTTE NC
SWL ECOSOLVE LLC PO BOX 680517 NON GC N/A N/A
NCS-00801/ACTIVE CHARLOTTE NC
SWL L&L ENVIRONMENTAL SERVICES PO BOX 19491 NON GC N/A N/A
NCS-01094/ACTIVE CHARLOTTE NC
SWL LEFLER-STUART #369 PO BOX 31547 NON GC N/A N/A
NCS-00761/ACTIVE CHARLOTTE NC
SWL OLD CHARLOTTE LDFL/ VANGUARD 77 CENTER NON GC N/A N/A
NONCD0001065/PRE-1983 CHARLOTTE NC
SWL STATESVILLE RD. LF EAST SIDE OF NORTHERLY NO NON GC N/A N/A
NCD000605097/PRE-1983 CHARLOTTE NC
LUST ARROWOOD ROAD EXTENSION ARROWOOD AND PARK ACCESS R NON GC N/A N/A
NCI-085236/CLOSED OUT CHARLOTTE NC
LUST CSX PINOCA YARD CHEMWAY AREA OF CHARLOTTE NON GC N/A N/A
NCI-085419/DI CHARLOTTE NC
LUST EPISCOPAL DIOCESE OF NC 0 ARROWOOD RD NON GC N/A N/A
NCI-010492/CLOSED OUT CHARLOTTE NC 28217
LUST PAW CREEK - PLANTATION PIPELIN PIPELINE R-O-W WEST OF TER NON GC N/A N/A
NCI-085290/RESPONSE CHARLOTTE NC
BROWNFIE 330 WEST TREMONT W TREMONT AVE & SOUTH TRYO NON GC N/A N/A
14009-10-60/FINALIZED CHARLOTTE NC
TRIBALLA BUREAU OF INDIAN AFFAIRS CONTACT I UNKNOWN NON GC N/A N/A
BIA-28217/ NC 28217
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:48 DIST/DIR:0.08 SW ELEVATION:720 MAP ID:1
NAME:MONARCH SPRINKLER REV:6/1/12
ADDRESS:308 CLANTON RD ID1:0-014170
CHARLOTTE NC 28210 ID2:00-0-0000014170
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:NISBET OIL COMPANY PHONE:
SOURCE:NCDENR
Site Details Page - 1
SITE INFORMATION
TOTAL NUMBER OF TANKS: 1
CONTACT INFORMATION: NISBET OIL COMPANY
1818 BAXTER STREET/PO BOX 35367
CHARLOTTE NC 28204-5367
TANK NUMBER: 1
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Gasoline, Gas Mix
CAPACITY IN GALLONS: 1000
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
ARCHIVED INFORMATION AS OF 2011
TANK NUMBER: 1
INSTALLATION DATE: 19700325
CLOSED DATE: 19881001
STATUS: PERMANENTLY CLOSED
CONTENTS: GASOLINE, GASOLINE MIXTURE
CAPACITY IN GALLONS: 1000
COMMENTS:
CONSTRUCTION MATERIAL: STEEL
INTERIOR: NONE
EXTERIOR: PAINT
CORROSION PROTECTION:
LEAK DETECTION:
PIPING MATERIAL: STEEL
PIPE CORROSION PROTECTION:
PIPE LEAK DETECTION:
OVERFLOW PROTECTION:
FINANCIAL RESPONSIBILITY:
CERTIFICATION TYPE:
GPS SITING CONFIRMED:N
PERSON CONFIRMING:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:20 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:PELTON & CRANE PLANT (FORMER)REV:6/8/12
ADDRESS:200 CLANTON RD ID1:NCD055162069
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 2
SITE INFORMATION
EPA ID:NCD055162069INCIDENT ID:85670
REP DISCOVERY DATE:14-MAY-01NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:
INCIDENT COMMENTS:INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO. UIC Permit #WI0300104 for injecting
Slow Release Substrate to enhance reductive dechlorination.
DATE ADDED: 2/19/1998RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: MF
MEDIA CONTAMINATEDCONTAMINANT TYPE
SOILMETALS
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: YESREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
DOCKET NUMBER: 99188ORDER, REQUEST, AOC: AA-REC
RECEIVING PARTY: SIEMENS MEDICAL SYSTEMS, INC.MEDIA COVERED: ENTIRE SITE
EXECUTION DATE: 1/29/2000WITHDRAWN: NO
DATE COMPLETED: NOTICE CANCELED:
STAFF INITIALS: KCREC CODE:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
SPILLS
SEARCH ID:31 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:CLANTON ROAD FACILITY REV:12/6/05
ADDRESS:200 CLANTON RD ID1:15846
CHARLOTTE NC ID2:
MECKLENBURG STATUS:CLOSED OUT
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 3
SITE INFORMATION
OWNER/OPERATOR:
DATE OF RELEASE:
DATE SUBMITTED: 7/16/1996
DESCRIPTION OF INCIDENT: MINOR SOIL CONTAMINATION CONFIRMED DURING REMOVAL OF USTS.
CONTAMINATION INFORMATION
GROUNDWATER CONTAMINATED?: N
MAJOR SOIL CONTAMINATION?: Y
MATERIAL INVOLVED (1): WASTE OIL
AMOUNT LOST (1):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (2):
AMOUNT LOST (2):
AMOUNT RECOVERED (2):
MATERIAL INVOLVED (3):
AMOUNT LOST (3):
AMOUNT RECOVERED (3):
NUMBER OF WELLS AFFECTED: 0
NAME(S) OF CONTAMINATED WELLS:
PRIORITY INFORMATION:
RISK SITE?:
SITE PRIORITY:
PRIORITY CODE:
PRIORITY UPDATE:
STATUS INFORMATION:
LAST MODIFIED: 8/19/1996
INCIDENT PHASE: CLOSED OUT
NOV ISSUED:
NORR ISSUED:
45 DAY REPORT:
CORRECTIVE ACTION PLAN:
CLOSURE REQ DATE:
CLOSE-OUT REPORT: 7/16/1996
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
SPILLS
SEARCH ID:32 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:PELTON & CRANE PLANT (FORMER,REV:12/6/05
ADDRESS:200 CLANTON RD ID1:85670
CHARLOTTE NC ID2:
MECKLENBURG STATUS:NOD
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 4
SITE INFORMATION
OWNER/OPERATOR: ,
NC
DATE OF RELEASE: 5/14/2001
DATE SUBMITTED: 5/14/2001
DESCRIPTION OF INCIDENT: INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO. UIC Permit #WI0300104 for
injecting Slow Release Substrate to enhance reductive dechlorin
CONTAMINATION INFORMATION
GROUNDWATER CONTAMINATED?: Y
MAJOR SOIL CONTAMINATION?:
MATERIAL INVOLVED (1):
AMOUNT LOST (1):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (2):
AMOUNT LOST (2):
AMOUNT RECOVERED (2):
MATERIAL INVOLVED (3):
AMOUNT LOST (3):
AMOUNT RECOVERED (3):
NUMBER OF WELLS AFFECTED: 0
NAME(S) OF CONTAMINATED WELLS:
PRIORITY INFORMATION:
RISK SITE?:
SITE PRIORITY:
PRIORITY CODE: NOD
PRIORITY UPDATE:
STATUS INFORMATION:
LAST MODIFIED: 4/18/2005
INCIDENT PHASE: NOD
NOV ISSUED:
NORR ISSUED:
45 DAY REPORT:
CORRECTIVE ACTION PLAN:
CLOSURE REQ DATE:
CLOSE-OUT REPORT:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:45 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:CLANTON ROAD FACILITY REV:6/10/11
ADDRESS:200 CLANTON RD ID1:MO-4766
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 5
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-4766
INCIDENT NUMBER:15846
CD NUMBER:5
REEL NUMBER:0
REGIONAL CONTACT:GSB
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:BOTH
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:7/17/1996
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:4/15/1993
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:5
RESPONSIBLE OWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:45 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:CLANTON ROAD FACILITY REV:6/10/11
ADDRESS:200 CLANTON RD ID1:MO-4766
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 6
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:49 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:THE PELTON & CRANE CO.REV:6/1/12
ADDRESS:200 CLANTON RD ID1:0-014524
CHARLOTTE NC 28210 ID2:00-0-0000014524
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:THE PELTON & CRANE CO.PHONE:
SOURCE:NCDENR
Site Details Page - 7
- Continued on next page -
SITE INFORMATION
TOTAL NUMBER OF TANKS: 2
CONTACT INFORMATION: THE PELTON & CRANE CO.
P.O. BOX 7800
CHARLOTTE NC 28241-7800
TANK NUMBER: 1
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Oil, New/Used/Mix
CAPACITY IN GALLONS: 2000
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
TANK NUMBER: 2
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Oil, New/Used/Mix
CAPACITY IN GALLONS: 650
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
REGIONAL UST DATA
UST NUMBER:MO-4766
INCIDENT NUMBER:15846
CD NUMBER:5
REEL NUMBER:0
REGIONAL CONTACT:GSB
REGIONAL OFFICE:MOR
DATE OCCURRED:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:49 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:THE PELTON & CRANE CO.REV:6/1/12
ADDRESS:200 CLANTON RD ID1:0-014524
CHARLOTTE NC 28210 ID2:00-0-0000014524
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:THE PELTON & CRANE CO.PHONE:
SOURCE:NCDENR
Site Details Page - 8
- Continued on next page -
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:BOTH
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:7/17/1996
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:4/15/1993
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:5
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
COMMENTS:
ARCHIVED INFORMATION AS OF 2011
TANK NUMBER: 1
INSTALLATION DATE: 19840602
CLOSED DATE: 19921001
STATUS: PERMANENTLY CLOSED
CONTENTS: OIL, NEW/USED/MIXTURE
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:49 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:THE PELTON & CRANE CO.REV:6/1/12
ADDRESS:200 CLANTON RD ID1:0-014524
CHARLOTTE NC 28210 ID2:00-0-0000014524
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:THE PELTON & CRANE CO.PHONE:
SOURCE:NCDENR
Site Details Page - 9
CAPACITY IN GALLONS: 2000
COMMENTS:
CONSTRUCTION MATERIAL: STEEL
INTERIOR: UNKNOWN
EXTERIOR: PAINT
CORROSION PROTECTION:
LEAK DETECTION:
PIPING MATERIAL: STEEL
PIPE CORROSION PROTECTION:
PIPE LEAK DETECTION:
OVERFLOW PROTECTION:
FINANCIAL RESPONSIBILITY:
CERTIFICATION TYPE:
GPS SITING CONFIRMED:N
PERSON CONFIRMING:
TANK NUMBER: 2
INSTALLATION DATE: 19780604
CLOSED DATE: 19840301
STATUS: PERMANENTLY CLOSED
CONTENTS: OIL, NEW/USED/MIXTURE
CAPACITY IN GALLONS: 650
COMMENTS:
CONSTRUCTION MATERIAL: STEEL
INTERIOR: UNKNOWN
EXTERIOR: PAINT
CORROSION PROTECTION:
LEAK DETECTION:
PIPING MATERIAL: STEEL
PIPE CORROSION PROTECTION:
PIPE LEAK DETECTION:
OVERFLOW PROTECTION:
FINANCIAL RESPONSIBILITY:
CERTIFICATION TYPE:
GPS SITING CONFIRMED:N
PERSON CONFIRMING:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:56 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:CLANTON ROAD FACILITY REV:6/1/12
ADDRESS:200 CLANTON RD ID1:NCI-015846
CHARLOTTE NC 28217 ID2:15846
MECKLENBURG STATUS:CLOSED OUT
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 10
REGIONAL UST DATA
UST NUMBER:MO-4766
INCIDENT NUMBER:15846
CD NUMBER:5
REEL NUMBER:0
REGIONAL CONTACT:GSB
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:BOTH
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:7/17/1996
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:4/15/1993
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:5
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:65 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:PELTON & CRANE PLANT (FORMER)REV:10/1/01
ADDRESS:200 CLANTON RD ID1:NCI-085670
CHARLOTTE NC ID2:
MECKLENBURG STATUS:NOD
CONTACT: PHONE:
SOURCE:
Site Details Page - 11
OWNER/OPERATOR:
DATE OF RELEASE:
DATE SUBMITTED: 5/14/2001
DESCRIPTION OF INCIDENT: NO FILE AT MRO. INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO.
CONTAMINATION INFORMATION
GROUNDWATER CONTAMINATED?: Y
MAJOR SOIL CONTAMINATION?:
MATERIAL INVOLVED (1):
AMOUNT LOST (1):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (2):
AMOUNT LOST (2):
AMOUNT RECOVERED (2):
MATERIAL INVOLVED (3):
AMOUNT LOST (3):
AMOUNT RECOVERED (3):
NUMBER OF WELLS AFFECTED: 0
NAME(S) OF CONTAMINATED WELLS:
PRIORITY INFORMATION:
RISK SITE?:
SITE PRIORITY: 0
PRIORITY CODE:
PRIORITY UPDATE:
STATUS INFORMATION:
LAST MODIFIED:
INCIDENT PHASE: NOD
NOV ISSUED:
NORR ISSUED:
45 DAY REPORT:
CORRECTIVE ACTION PLAN:
CLOSURE REQ DATE:
CLOSE-OUT REPORT:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:79 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:FORMER PELTON & CRANEPLANT REV:5/10/07
ADDRESS:200 CLANTON RD ID1:NCBR-0206-047
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:
Site Details Page - 12
SITE INFORMATION
PROSPECTIVE DEVELOPER:CLANTON PARTNERS I, LLC
STATUS:ACTIVE = ACTIVE ELIGBLE PROJECT
DESCRIPTION:Site of a manufacturing facility specializing in equipment for the dental industry, this approximately 6-acre property has known
metals, chlorinated solvent and PAH contamination in soil and groundwater. PD intends to redevelop the site into office and showroom space for
non-profit involved in serving the educational, employment and enrichment needs of developmentally disabled children and adults.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:80 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:PELTON & CRANE PLANT REV:9/30/10
ADDRESS:200 CLANTON RD ID1:NCBR-1106-033
CHARLOTTE NC ID2:
MECKLENBURG STATUS:FINALIZED
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 13
SITE INFORMATION
PROSPECTIVE DEVELOPER:CLANTON PARTNERS I, LLC
FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS
DESCRIPTION:The Property (Tax Parcel Identification Number is 14702106) is located at 200 Clanton Road, Charlotte, North Carolina and
comprises approximately 6 acres. The Pelton & Crane Company, a division of Siemens Medical Solutions, USA, Inc., manufactured products for the
dental industry on the Brownfields Property from 1955 until 1992. Soil and groundwater at the site are impacted by chlorinated solvents.
Prospective Developer has committed itself to redevelopment of the Brownfields Property for no uses other than for warehouse and, with prior
written DENR approval, other commercial purposes.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:81 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:PELTON AND CRANE PLANT - FORMER REV:8/10/12
ADDRESS:200 CLANTON RD ID1:09034-05-60
CHARLOTTE NC ID2:09034-05-60
MECKLENBURG STATUS:FINALIZED
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 14
SITE INFORMATION
PROJECT NUMBER:09034-05-60
For more information please contact the NCDENR at (919) 707-8383
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
VCP
SEARCH ID:88 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2
NAME:PELTON & CRANE PLANT (FORMER)REV:7/30/07
ADDRESS:200 CLANTON RD ID1:VC-NCD055162069
CHARLOTTE NC ID2:NCD055162069
MECKLENBURG STATUS:VOLUNTARY CLEANUP
CONTACT: PHONE:
SOURCE:
Site Details Page - 15
SITE INFORMATION
DATE ADDED: 2/19/1998RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: MF
MEDIA CONTAMINATEDCONTAMINANT TYPE
SOILMETALS
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: YESREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NONON HAZ SUB SITE VOL:NO
NON HAZ SUB SITE NFA:NO
ORDERS, AGREEMENTS, AND SOLICITATIONS
DOCKET NUMBER: 99188ORDER, REQUEST, AOC: AA-REC
RECEIVING PARTY: SIEMENS MEDICAL SYSTEMS, INC.MEDIA COVERED: ENTIRE SITE
EXECUTION DATE: 1/29/2000WITHDRAWN: NO
DATE COMPLETED: NOTICE CANCELED:
STAFF INITIALS: KCREC CODE:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
SPILLS
SEARCH ID:29 DIST/DIR:0.10 SW ELEVATION:724 MAP ID:3
NAME:77 CORPORATE PARK REV:6/1/12
ADDRESS:CLANTON ROAD, SOUTH TRYON STRE ID1:86378
CHARLOTTE NC 28217 ID2:MO-86378
MECKLENBURG STATUS:CURRENT RECORD
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 16
SITE INFORMATION
OWNER/OPERATOR: UNKNOWN,
DATE OF RELEASE: 9/10/2002
DATE SUBMITTED: 9/19/2002
DESCRIPTION OF INCIDENT: O&G CONTAM FOUND IN SOIL. MOST LIKELY SOURCE IS FORMER JUNKYARD THAT OCCUPIED A PORTION OF
THE PROPERTY PRIOR TO REDEVELOPMENT THAT OCCURRED 1979-MID 80S. SITE
CONTAMINATION INFORMATION
GROUNDWATER CONTAMINATED?: N
MAJOR SOIL CONTAMINATION?:
MATERIAL INVOLVED (1):
AMOUNT LOST (1):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (2):
AMOUNT LOST (2):
AMOUNT RECOVERED (2):
MATERIAL INVOLVED (3):
AMOUNT LOST (3):
AMOUNT RECOVERED (3):
NUMBER OF WELLS AFFECTED: 0
NAME(S) OF CONTAMINATED WELLS:
PRIORITY INFORMATION:
RISK SITE?:
SITE PRIORITY: 0
PRIORITY CODE: E
PRIORITY UPDATE:
STATUS INFORMATION:
LAST MODIFIED: 9/19/2002
INCIDENT PHASE: DI
NOV ISSUED:
NORR ISSUED:
45 DAY REPORT:
CORRECTIVE ACTION PLAN:
CLOSURE REQ DATE:
CLOSE-OUT REPORT:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
SPILLS
SEARCH ID:30 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4
NAME:ACOUSTICS, INC.REV:12/6/05
ADDRESS:3324 PALTON ST ID1:10174
CHARLOTTE NC ID2:
MECKLENBURG STATUS:CLOSED OUT
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 17
SITE INFORMATION
OWNER/OPERATOR:
DATE OF RELEASE: 12/28/1992
DATE SUBMITTED: 5/14/1993
DESCRIPTION OF INCIDENT: A SMALL AMOUNT OF SOIL CONTAM. WAS DISCOVERED UPON REMOVAL OF UST.
CONTAMINATION INFORMATION
GROUNDWATER CONTAMINATED?: N
MAJOR SOIL CONTAMINATION?: Y
MATERIAL INVOLVED (1): GASOLINE
AMOUNT LOST (1):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (2):
AMOUNT LOST (2):
AMOUNT RECOVERED (2):
MATERIAL INVOLVED (3):
AMOUNT LOST (3):
AMOUNT RECOVERED (3):
NUMBER OF WELLS AFFECTED: 0
NAME(S) OF CONTAMINATED WELLS:
PRIORITY INFORMATION:
RISK SITE?:
SITE PRIORITY:
PRIORITY CODE:
PRIORITY UPDATE:
STATUS INFORMATION:
LAST MODIFIED: 2/19/1997
INCIDENT PHASE: CLOSED OUT
NOV ISSUED:
NORR ISSUED:
45 DAY REPORT:
CORRECTIVE ACTION PLAN:
CLOSURE REQ DATE:
CLOSE-OUT REPORT: 5/13/1997
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:35 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4
NAME:ACOUSTICS INCORPORATED REV:6/1/12
ADDRESS:3324 PELTON ST ID1:0-026559
CHARLOTTE NC 28217 ID2:00-0-0000026559
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:ACOUSTICS INCORPORATED PHONE:
SOURCE:NCDENR
Site Details Page - 18
- Continued on next page -
SITE INFORMATION
TOTAL NUMBER OF TANKS: 1
CONTACT INFORMATION: ACOUSTICS INCORPORATED
3324 PELTON STREET
CHARLOTTE NC 28217
TANK NUMBER: 1
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Gasoline, Gas Mix
CAPACITY IN GALLONS: 2000
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:1
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
REGIONAL UST DATA
UST NUMBER:MO-3782
INCIDENT NUMBER:10174
CD NUMBER:3
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:12/28/1992
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:35 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4
NAME:ACOUSTICS INCORPORATED REV:6/1/12
ADDRESS:3324 PELTON ST ID1:0-026559
CHARLOTTE NC 28217 ID2:00-0-0000026559
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:ACOUSTICS INCORPORATED PHONE:
SOURCE:NCDENR
Site Details Page - 19
- Continued on next page -
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:5/13/1993
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:12/28/1992
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:3
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
COMMENTS:
ARCHIVED INFORMATION AS OF 2011
TANK NUMBER: 1
INSTALLATION DATE: 19640927
CLOSED DATE: 19921231
STATUS: PERMANENTLY CLOSED
CONTENTS: GASOLINE, GASOLINE MIXTURE
CAPACITY IN GALLONS: 2000
COMMENTS:
CONSTRUCTION MATERIAL: STEEL
INTERIOR: UNKNOWN
EXTERIOR: UNKNOWN
CORROSION PROTECTION:
LEAK DETECTION:
PIPING MATERIAL: UNKNOWN
PIPE CORROSION PROTECTION:
PIPE LEAK DETECTION:
OVERFLOW PROTECTION:
FINANCIAL RESPONSIBILITY:
CERTIFICATION TYPE:
GPS SITING CONFIRMED:N
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:35 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4
NAME:ACOUSTICS INCORPORATED REV:6/1/12
ADDRESS:3324 PELTON ST ID1:0-026559
CHARLOTTE NC 28217 ID2:00-0-0000026559
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:ACOUSTICS INCORPORATED PHONE:
SOURCE:NCDENR
Site Details Page - 20
PERSON CONFIRMING:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:36 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4
NAME:ACOUSTICS, INC.REV:6/10/11
ADDRESS:3324 PELTON ST ID1:MO-3782
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 21
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-3782
INCIDENT NUMBER:10174
CD NUMBER:3
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:12/28/1992
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:5/13/1993
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:12/28/1992
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:3
RESPONSIBLE OWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:36 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4
NAME:ACOUSTICS, INC.REV:6/10/11
ADDRESS:3324 PELTON ST ID1:MO-3782
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 22
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:50 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4
NAME:ACOUSTICS, INC.REV:6/1/12
ADDRESS:3324 PALTON ST ID1:NCI-010174
CHARLOTTE NC 28217 ID2:10174
MECKLENBURG STATUS:CLOSED OUT
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 23
REGIONAL UST DATA
UST NUMBER:MO-3782
INCIDENT NUMBER:10174
CD NUMBER:3
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:12/28/1992
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:5/13/1993
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:12/28/1992
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:3
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:43 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5
NAME:CATS BUS M AND O REV:6/1/12
ADDRESS:3251 S TRYON ST ID1:0-03679
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:DOUG PIEROTTI PHONE:7044325212
SOURCE:NCDENR
Site Details Page - 24
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-8160
INCIDENT NUMBER:36749
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:DPB
REGIONAL OFFICE:MOR
DATE OCCURRED:12/23/2009
RESPONSIBLE COMPANY:
CITY OF CHARLOTTE
600 EAST FOURTH STREET
CHARLOTTE ,NC , 282022844
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:1
SITE PRIORITY:
RISK:U
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:RESIDENTIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:12/23/2009
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:0
RESPONSIBLE OWNER:-1
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:43 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5
NAME:CATS BUS M AND O REV:6/1/12
ADDRESS:3251 S TRYON ST ID1:0-03679
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:DOUG PIEROTTI PHONE:7044325212
SOURCE:NCDENR
Site Details Page - 25
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
COMMENTS:tank pump controller malfunction, which resulted in inadvertently overfilling UST-3. Release then resulting from damaged spill
bucket. Product migrated from stone backfill in the tankpit to a crack in the storm drain, which lead to an outfall, which lead to a drainage ditch, to
a tributary of Irwin Creek. Surface water notified. As of 1-20-2010, several AFVR events have been conducted on an installed six inch recovery
well, to dewater (water source unknown at this time) and to remove product from the pit as an emergency measure. Also storm water pipe has
been and currently been through several repairs.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:44 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5
NAME:CATS BUS MAINTENANCE AND OPS FAC REV:6/1/12
ADDRESS:3251 S TRYON ST ID1:0-036729
CHARLOTTE NC 28217 ID2:00-0-0000036729
MECKLENBURG STATUS:CURRENTLY OPERATIONAL
CONTACT:CHARLOTTE AREA TRANSIT SYSTEM PHONE:
SOURCE:NCDENR
Site Details Page - 26
- Continued on next page -
SITE INFORMATION
TOTAL NUMBER OF TANKS: 4
CONTACT INFORMATION: CHARLOTTE AREA TRANSIT SYSTEM
600 E. 4TH ST./DAVID WOLFE-E&PM
CHARLOTTE NC 28202-2844
TANK NUMBER: 1
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Diesel
CAPACITY IN GALLONS: 40000
TANK CONSTRUCTION:5
PIPE CONSTRUCTION:6
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:NO
COMMERCIAL TANK:YES
REGULATED TANK:YES
TANK NUMBER: 2
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Diesel
CAPACITY IN GALLONS: 40000
TANK CONSTRUCTION:5
PIPE CONSTRUCTION:6
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:NO
COMMERCIAL TANK:YES
REGULATED TANK:YES
TANK NUMBER: 3
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Diesel
CAPACITY IN GALLONS: 40000
TANK CONSTRUCTION:5
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:44 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5
NAME:CATS BUS MAINTENANCE AND OPS FAC REV:6/1/12
ADDRESS:3251 S TRYON ST ID1:0-036729
CHARLOTTE NC 28217 ID2:00-0-0000036729
MECKLENBURG STATUS:CURRENTLY OPERATIONAL
CONTACT:CHARLOTTE AREA TRANSIT SYSTEM PHONE:
SOURCE:NCDENR
Site Details Page - 27
- Continued on next page -
PIPE CONSTRUCTION:6
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:NO
COMMERCIAL TANK:YES
REGULATED TANK:YES
TANK NUMBER: 4
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Diesel
CAPACITY IN GALLONS: 10000
TANK CONSTRUCTION:5
PIPE CONSTRUCTION:6
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:NO
COMMERCIAL TANK:YES
REGULATED TANK:YES
ARCHIVED INFORMATION AS OF 2011
TANK NUMBER: 1
INSTALLATION DATE: 20040430
CLOSED DATE:
STATUS: CURRENTLY OPERATIONAL
CONTENTS: DIESEL, DIESEL MIXTURE
CAPACITY IN GALLONS: 40000
COMMENTS:
CONSTRUCTION MATERIAL: FIBERGLASS REINFORCED PLASTIC
INTERIOR: DOUBLE WALL
EXTERIOR: FRP
CORROSION PROTECTION: FRP TANK/PIPING
LEAK DETECTION: AUTOMATIC TANK GAUGING
PIPING MATERIAL: DOUBLE WALL
PIPE CORROSION PROTECTION: FRP TANK/PIPING
PIPE LEAK DETECTION: AUTOMATIC LINE LEAK DETECTORS
OVERFLOW PROTECTION: CATCHMENT BASIN
FINANCIAL RESPONSIBILITY: FINANCIAL TEST OF SELF INSURANCE
CERTIFICATION TYPE: INSTALLER CERTIFIED BY TANK AND PIPING MANUFACTURERS
GPS SITING CONFIRMED:
PERSON CONFIRMING:
TANK NUMBER: 2
INSTALLATION DATE: 20040430
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:44 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5
NAME:CATS BUS MAINTENANCE AND OPS FAC REV:6/1/12
ADDRESS:3251 S TRYON ST ID1:0-036729
CHARLOTTE NC 28217 ID2:00-0-0000036729
MECKLENBURG STATUS:CURRENTLY OPERATIONAL
CONTACT:CHARLOTTE AREA TRANSIT SYSTEM PHONE:
SOURCE:NCDENR
Site Details Page - 28
- More Details Exist For This Site; Max Page Limit Reached -
CLOSED DATE:
STATUS: CURRENTLY OPERATIONAL
CONTENTS: DIESEL, DIESEL MIXTURE
CAPACITY IN GALLONS: 40000
COMMENTS:
CONSTRUCTION MATERIAL: FIBERGLASS REINFORCED PLASTIC
INTERIOR: DOUBLE WALL
EXTERIOR: FRP
CORROSION PROTECTION: FRP TANK/PIPING
LEAK DETECTION: AUTOMATIC TANK GAUGING
PIPING MATERIAL: DOUBLE WALL
PIPE CORROSION PROTECTION: FRP TANK/PIPING
PIPE LEAK DETECTION: AUTOMATIC LINE LEAK DETECTORS
OVERFLOW PROTECTION: CATCHMENT BASIN
FINANCIAL RESPONSIBILITY: FINANCIAL TEST OF SELF INSURANCE
CERTIFICATION TYPE: INSTALLER CERTIFIED BY TANK AND PIPING MANUFACTURERS
GPS SITING CONFIRMED:
PERSON CONFIRMING:
TANK NUMBER: 3
INSTALLATION DATE: 20040430
CLOSED DATE:
STATUS: CURRENTLY OPERATIONAL
CONTENTS: DIESEL, DIESEL MIXTURE
CAPACITY IN GALLONS: 40000
COMMENTS:
CONSTRUCTION MATERIAL: FIBERGLASS REINFORCED PLASTIC
INTERIOR: DOUBLE WALL
EXTERIOR: FRP
CORROSION PROTECTION: FRP TANK/PIPING
LEAK DETECTION: AUTOMATIC TANK GAUGING
PIPING MATERIAL: DOUBLE WALL
PIPE CORROSION PROTECTION: FRP TANK/PIPING
PIPE LEAK DETECTION: AUTOMATIC LINE LEAK DETECTORS
OVERFLOW PROTECTION: CATCHMENT BASIN
FINANCIAL RESPONSIBILITY: FINANCIAL TEST OF SELF INSURANCE
CERTIFICATION TYPE: INSTALLER CERTIFIED BY TANK AND PIPING MANUFACTURERS
GPS SITING CONFIRMED:
PERSON CONFIRMING:
TANK NUMBER: 4
INSTALLATION DATE: 20040430
CLOSED DATE:
STATUS: CURRENTLY OPERATIONAL
CONTENTS: DIESEL, DIESEL MIXTURE
CAPACITY IN GALLONS: 10000
COMMENTS:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:54 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5
NAME:CATS BUS M AND O REV:6/1/12
ADDRESS:3251 S TRYON ST ID1:NCI-036749
CHARLOTTE NC 28217 ID2:36749
MECKLENBURG STATUS:CURRENT RECORD
CONTACT:DOUG PIEROTTI PHONE:7044325212
SOURCE:NCDENR
Site Details Page - 29
REGIONAL UST DATA
UST NUMBER:MO-8160
INCIDENT NUMBER:36749
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:DPB
REGIONAL OFFICE:MOR
DATE OCCURRED:12/23/2009
RESPONSIBLE COMPANY:
CITY OF CHARLOTTE
600 EAST FOURTH STREET
CHARLOTTE ,NC , 282022844
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:1
SITE PRIORITY:
RISK:U
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:RESIDENTIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:12/23/2009
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:0
RESPONSIBLE OWNER:-1
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:47 DIST/DIR:0.13 SW ELEVATION:730 MAP ID:6
NAME:JOE B. WILLIAMS PROPERTY REV:6/1/12
ADDRESS:3500 S TRYON ST ID1:MO-4083
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:MR. JOE WILLIAMS PHONE:803-831-1822
SOURCE:NCDENR
Site Details Page - 30
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-4083
INCIDENT NUMBER:12153
CD NUMBER:211
REEL NUMBER:0
REGIONAL CONTACT:CBC
REGIONAL OFFICE:MOR
DATE OCCURRED:5/2/1994
RESPONSIBLE COMPANY:
6121 CHARLOTTE HIGHWAY
YORK ,SC , 29745
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:5/17/1994
VIOLATION:
PHASE REQUIRED:2
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:RESIDENTIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:6/3/2004
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:4/5/2004
CLEAN UP:5/2/1994
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:211
RESPONSIBLE OWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:47 DIST/DIR:0.13 SW ELEVATION:730 MAP ID:6
NAME:JOE B. WILLIAMS PROPERTY REV:6/1/12
ADDRESS:3500 S TRYON ST ID1:MO-4083
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:MR. JOE WILLIAMS PHONE:803-831-1822
SOURCE:NCDENR
Site Details Page - 31
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
COMMENTS:Removal of five 4,000-gallon gasoline and one 4,000-gallon diesel tanks in 1993. Closure sampling indicated TPH as high as 14,000.
LSA indicates no soil > residential. Groundwater exceeds 2L. Low risk.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:61 DIST/DIR:0.13 SW ELEVATION:730 MAP ID:6
NAME:JOE B. WILLIAMS PROPERTY REV:6/1/12
ADDRESS:3500 S STRYON ST ID1:NCI-012153
CHARLOTTE NC 28217 ID2:12153
MECKLENBURG STATUS:CLOSED OUT
CONTACT:MR. JOE WILLIAMS PHONE:803-831-1822
SOURCE:NCDENR
Site Details Page - 32
REGIONAL UST DATA
UST NUMBER:MO-4083
INCIDENT NUMBER:12153
CD NUMBER:211
REEL NUMBER:0
REGIONAL CONTACT:CBC
REGIONAL OFFICE:MOR
DATE OCCURRED:5/2/1994
RESPONSIBLE COMPANY:
6121 CHARLOTTE HIGHWAY
YORK ,SC , 29745
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:5/17/1994
VIOLATION:
PHASE REQUIRED:2
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:RESIDENTIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:6/3/2004
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:4/5/2004
CLEAN UP:5/2/1994
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:211
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:34 DIST/DIR:0.13 NE ELEVATION:702 MAP ID:7
NAME:3206 SOUTH TRYON REV:6/1/12
ADDRESS:3206 S TRYON ST ID1:MO-2336
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:HADI GHRAIRI PHONE:
SOURCE:NCDENR
Site Details Page - 33
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-2336
INCIDENT NUMBER:
CD NUMBER:59
REEL NUMBER:0
REGIONAL CONTACT:ARL
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
JANEEN INVESTMENT
3030 S TRYON STREET
CHARLOTTE ,NC , 28217
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:
RISK OF INCIDENT:
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:1/8/2001
CASE CLOSED:1/10/2001
CONTAMINATION:NONE
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:59
RESPONSIBLE OWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:34 DIST/DIR:0.13 NE ELEVATION:702 MAP ID:7
NAME:3206 SOUTH TRYON REV:6/1/12
ADDRESS:3206 S TRYON ST ID1:MO-2336
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:HADI GHRAIRI PHONE:
SOURCE:NCDENR
Site Details Page - 34
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
COMMENTS:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
RCRAGN
SEARCH ID:5 DIST/DIR:0.18 SE ELEVATION:767 MAP ID:8
NAME:ALTEC INDUSTRIES, INC REV:9/14/10
ADDRESS:3335 PELTON ST ID1:NCD986232510
CHALOTTE NC 28220 ID2:
MECKLENBURG STATUS:SGN
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 35
CONTACT INFORMATION:
RYAN MCKINNEY
7045250059
RYAN.MCKINNEY@ALTEC.COM
UNIVERSE INFORMATION:
GOVERNMENT PERFORMANCE AND RESULTS ACT (GPRA)
GPRA CA BASELINE UNIVERSE:NO
GPRA CA 2008:NO
SUBJECT TO CORRECTIVE ACTION (SUBJCA)
SUBJCA:NO
SUBJCA TSD 3004:NO
SUBJCA NON TSD:NO
SUBJCA TSD DISCRETION:NO
PERMIT WORKLOAD:-----
CLOSURE WORKLOAD:-----
POST CLOSURE WORKLOAD:-----
PERMITTING /CLOSURE/POST-CLOSURE PROGRESS:-----
CORRECTIVE ACTION WORKLOAD:NO
GENERATOR STATUS:SQG
TRANSPORTER:NO
UNIVERSAL WASTE:NO
RECYCLER:NO
USED OIL:NO
IMPORTER:NO
MIXED WASTE GENERATOR:NO
ONSITE BURNER EXEMPT:NO
FURNACE EXEMPTION:NO
UNDERGROUND INJECTION:NO
NAIC 1:Motor Vehicle Body Manufacturing
NAIC 2:
NAIC 3:
NAIC 4:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:38 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9
NAME:BARCLAYS CAPITAL REV:12/21/10
ADDRESS:3417 TRADE PARK CT ID1:MO-180
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:
CONTACT:B.J. EADS PHONE:704-529-1766
SOURCE:NCDENR
Site Details Page - 36
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-180
INCIDENT NUMBER:
CD NUMBER:60
REEL NUMBER:0
REGIONAL CONTACT:ARL
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
BARCLAYS CAPITAL
3417 TRADE PARK COURT
CHARLOTTE ,NC , 28217
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:
RISK OF INCIDENT:
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:1/25/2000
CASE CLOSED:1/26/2000
CONTAMINATION:NONE
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:60
RESPONSIBLE OWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:38 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9
NAME:BARCLAYS CAPITAL REV:12/21/10
ADDRESS:3417 TRADE PARK CT ID1:MO-180
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:
CONTACT:B.J. EADS PHONE:704-529-1766
SOURCE:NCDENR
Site Details Page - 37
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:39 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9
NAME:BARCLAYS CAPITAL REV:6/1/12
ADDRESS:3417 TRADE PARK CT ID1:MO-0180
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:B.J. EADS PHONE:704-529-1766
SOURCE:NCDENR
Site Details Page - 38
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-0180
INCIDENT NUMBER:
CD NUMBER:60
REEL NUMBER:0
REGIONAL CONTACT:ARL
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
BARCLAYS CAPITAL
3417 TRADE PARK COURT
CHARLOTTE ,NC , 28217
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:
RISK OF INCIDENT:
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:1/25/2000
CASE CLOSED:1/26/2000
CONTAMINATION:NONE
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:60
RESPONSIBLE OWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:39 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9
NAME:BARCLAYS CAPITAL REV:6/1/12
ADDRESS:3417 TRADE PARK CT ID1:MO-0180
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:B.J. EADS PHONE:704-529-1766
SOURCE:NCDENR
Site Details Page - 39
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
COMMENTS:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:40 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9
NAME:BARCLAYS CAPITAL, INC.REV:6/1/12
ADDRESS:3417 TRADE PARK CT ID1:0-035914
CHARLOTTE NC 28217 ID2:00-0-0000035914
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:BARCLAYS CAPITAL, INC.PHONE:
SOURCE:NCDENR
Site Details Page - 40
SITE INFORMATION
TOTAL NUMBER OF TANKS: 1
CONTACT INFORMATION: BARCLAYS CAPITAL, INC.
3417 TRADE PARK CT ATTN:K NEWTON
CHARLOTTE NC 28217
TANK NUMBER: 1
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Diesel
CAPACITY IN GALLONS: 8000
TANK CONSTRUCTION:2
PIPE CONSTRUCTION:3
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
ARCHIVED INFORMATION AS OF 2011
TANK NUMBER: 1
INSTALLATION DATE: 19890101
CLOSED DATE: 19991228
STATUS: PERMANENTLY CLOSED
CONTENTS: DIESEL, DIESEL MIXTURE
CAPACITY IN GALLONS: 8000
COMMENTS:
CONSTRUCTION MATERIAL: FIBERGLASS REINFORCED PLASTIC
INTERIOR: FRP
EXTERIOR: FRP
CORROSION PROTECTION: FRP TANK/PIPING
LEAK DETECTION:
PIPING MATERIAL: FRP
PIPE CORROSION PROTECTION: FRP TANK/PIPING
PIPE LEAK DETECTION: MANUAL TANK GAUGING
OVERFLOW PROTECTION: CATCHMENT BASIN
FINANCIAL RESPONSIBILITY:
CERTIFICATION TYPE: INSTALLER CERTIFIED BY TANK AND PIPING MANUFACTURERS
GPS SITING CONFIRMED:N
PERSON CONFIRMING:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
RCRAGN
SEARCH ID:7 DIST/DIR:0.19 NE ELEVATION:717 MAP ID:10
NAME:CATS-BOD S TRYON BUS GARAGE REV:9/11/12
ADDRESS:3145 S TRYON ST ID1:NC0991302662
CHARLOTTE NC 28202 ID2:
MECKLENBURG STATUS:VGN
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 41
- Continued on next page -
SITE INFORMATION
CONTACT INFORMATION: JAY C FAGEL
S TRYON ST
CHARLOTTE NC 28217
PHONE: 704-336-4082
OWNER NAME:CHARLOTTE AREA TRANSIT SYSTEMS
OWNER TYPE:F-FEDERAL
OPERATOR:CHARLOTTE AREA TRANSIT SYSTEMS
OPERATOR_TYPE:F-FEDERAL
MAILING ADDRESS:3145 S TRYON ST
UNIVERSE INFORMATION:
RECEIVED DATE:06/28/2012
SUBJECT TO CORRECTIVE ACTION (SUBJCA)
SUBJCA:N - NO
SUBJCA TSD 3004:N - NO
SUBJCA NON TSD:N - NO
SIGNIFICANT NON-COMPLIANCE(SNC):N - NO
BEGINNING OF THE YEAR SNC:
PERMIT WORKLOAD:-----
CLOSURE WORKLOAD:-----
POST CLOSURE WORKLOAD:-----
PERMITTING /CLOSURE/POST-CLOSURE PROGRESS:-----
CORRECTIVE ACTION WORKLOAD:N - NO
GENERATOR STATUS:CEG - CONDITIONALLY EXEMPT SMALL QUANTITY GENERATORS: GENERATES LESS THAN 100 KG/MONTH OF
HAZARDOUS WASTE
INSTITUTIONAL CONTROL:N-NOENGINEERING CONTROL:N
HUMAN EXPOSURE:N-NOGW CONTROLS:N- NO
LAND TYPE:P-PRIVATESHORT TERM GEN:N
TRANS FACILITY:NREC WASTE FROM OFF SITE:N
IMPORTER ACTIVITY:N - NOMIXED WASTE GEN:N - NO
TRANS ACTIVITY:N - NOTSD ACTIVITY:N - NO
RECYCLER ACTIVITY:N - NOONSITE BURNER EXEMPT:N - NO
FURNACE EXEMPTION:N - NOUNDER INJECT ACTIVITY:N - NO
REC WASTE FROM OFF SITE:N - NOUNIV WASTE DEST FAC:N
USED OIL TRANS:N - NOUSED OIL PROCESSOR:N - NO
USED OIL REFINER:N - NOUSED OIL FUEL BURNER:N - NO
UO FUEL MARKETER TO BURNER:NUSED OIL SPEC MARKETER:N - NO
NAIC INFORMATION
485113 - BUS AND OTHER MOTOR VEHICLE TRANSIT SYSTEMS
485112 - COMMUTER RAIL SYSTEMS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
RCRAGN
SEARCH ID:7 DIST/DIR:0.19 NE ELEVATION:717 MAP ID:10
NAME:CATS-BOD S TRYON BUS GARAGE REV:9/11/12
ADDRESS:3145 S TRYON ST ID1:NC0991302662
CHARLOTTE NC 28202 ID2:
MECKLENBURG STATUS:VGN
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 42
ENFORCEMENT INFORMATION:
VIOLATION INFORMATION:
VIOLATION NUMBER: 1RESPONSIBLE: S - STATE
DETERMINED: 10/17/2010DETERMINED BY: S - STATE
CITATION: RESOLVED: 11/25/2011
TYPE: FEDERAL OR STATE STATUTE
HAZARDOUS WASTE INFORMATION:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
RCRAGN
SEARCH ID:8 DIST/DIR:0.19 SW ELEVATION:727 MAP ID:11
NAME:PROVIDENCE PAINT CO REV:9/11/12
ADDRESS:428 BLAIRHILL RD ID1:NCR000143172
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:SGN
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 43
- Continued on next page -
SITE INFORMATION
CONTACT INFORMATION: DENNIS KRESSNER
BLAIRHILL RD
CHARLOTTE NC 28217
PHONE: 7045211250
OWNER NAME:JERRY KRESSNER
OWNER TYPE:P-PRIVATE
OPERATOR:JERRY KRESSNER
OPERATOR_TYPE:P-PRIVATE
MAILING ADDRESS: PO BOX 11965
CHARLOTTE, NC 28220-1965
UNIVERSE INFORMATION:
RECEIVED DATE:08/10/2012
SUBJECT TO CORRECTIVE ACTION (SUBJCA)
SUBJCA:N - NO
SUBJCA TSD 3004:N - NO
SUBJCA NON TSD:N - NO
SIGNIFICANT NON-COMPLIANCE(SNC):N - NO
BEGINNING OF THE YEAR SNC:
PERMIT WORKLOAD:-----
CLOSURE WORKLOAD:-----
POST CLOSURE WORKLOAD:-----
PERMITTING /CLOSURE/POST-CLOSURE PROGRESS:-----
CORRECTIVE ACTION WORKLOAD:N - NO
GENERATOR STATUS:SQG - SMALL QUANTITY GENERATOR: GENERATES 100 - 1000 KG/MONTH OF HAZARDOUS WASTE
INSTITUTIONAL CONTROL:N-NOENGINEERING CONTROL:N
HUMAN EXPOSURE:N-NOGW CONTROLS:N- NO
LAND TYPE:P-PRIVATESHORT TERM GEN:N
TRANS FACILITY:NREC WASTE FROM OFF SITE:N
IMPORTER ACTIVITY:N - NOMIXED WASTE GEN:N - NO
TRANS ACTIVITY:N - NOTSD ACTIVITY:N - NO
RECYCLER ACTIVITY:N - NOONSITE BURNER EXEMPT:N - NO
FURNACE EXEMPTION:N - NOUNDER INJECT ACTIVITY:N - NO
REC WASTE FROM OFF SITE:N - NOUNIV WASTE DEST FAC:N
USED OIL TRANS:N - NOUSED OIL PROCESSOR:N - NO
USED OIL REFINER:N - NOUSED OIL FUEL BURNER:N - NO
UO FUEL MARKETER TO BURNER:NUSED OIL SPEC MARKETER:N - NO
NAIC INFORMATION
44412 - PAINT AND WALLPAPER STORES
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
RCRAGN
SEARCH ID:8 DIST/DIR:0.19 SW ELEVATION:727 MAP ID:11
NAME:PROVIDENCE PAINT CO REV:9/11/12
ADDRESS:428 BLAIRHILL RD ID1:NCR000143172
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:SGN
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 44
ENFORCEMENT INFORMATION:
VIOLATION INFORMATION:
HAZARDOUS WASTE INFORMATION:
D001 - Ignitable waste
D035 - Methyl ethyl ketone
F003 - The following spent non-halogenated solvents: Xylene, acetone, ethyl acetate, ethyl benzene, ethyl ether, methyl isobutyl ketone, n-butyl
alcohol, cyclohexanone, and methanol; all spent solvent mixtures/ blends containing, before use, only the above spent non- halogenated solvents;
and all spent solvent mixtures/blends containing, before use, one or more of the above non-halogenated solvents, and a total of ten percent or
more (by volume) of one or more of those solvents listed in F001, F002, F004, and F005; and still bottoms from the recovery of these spent solvents
and spent solvent mixtures.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
RCRAGN
SEARCH ID:9 DIST/DIR:0.20 SW ELEVATION:727 MAP ID:12
NAME:PURE CLEAN REV:9/14/10
ADDRESS:3601 S TRYON ST ID1:NCD982163180
CHARLOTTE NC 28205 ID2:
MECKLENBURG STATUS:SGN
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 45
SITE INFORMATION
CONTACT INFORMATION: WILLIAM CARSTENS
3601 S TRYON ST
CHARLOTTE NC 28217
PHONE: 7045250244
UNIVERSE INFORMATION:
NAIC INFORMATION
ENFORCEMENT INFORMATION:
AGENCY: S - STATEDATE: 11/23/1994
TYPE: 120 - WRITTEN INFORMAL
AGENCY: S - STATEDATE: 11/23/1994
TYPE: 120 - WRITTEN INFORMAL
VIOLATION INFORMATION:
VIOLATION NUMBER: 0001RESPONSIBLE: S - STATE
DETERMINED: 11/23/1994DETERMINED BY: S - STATE
CITATION: 130A-294-1
RESOLVED: 12/13/1994
TYPE: GENERATOR-GENERAL REQUIREMENTS
HAZARDOUS WASTE INFORMATION:
The following spent halogenated solvents: Tetrachloroethylene, methylene chloride, trichloroethylene, 1,1,1-trichloroethane, chlorobenzene, 1,1,2-
trichloro-1,2,2-trifluoroethane, ortho-dichlorobenzene, trichlorofluoromethane
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:11 DIST/DIR:0.20 SW ELEVATION:726 MAP ID:13
NAME:AMERICAN FENCE SOLVENTS REV:6/8/12
ADDRESS:3605 S TRYON ST ID1:NONCD0001255
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 46
SITE INFORMATION
EPA ID:NONCD0001255INCIDENT ID:85958
REP DISCOVERY DATE:23-OCT-01NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:REVU REPORT
INCIDENT COMMENTS:LOW LEVEL SOLVENTS (UP TO 10 PPB PCE) DETECTED IN MWS DURING PHASE II. OFFSITE SOURCE POSSIBLE. ALSO
ASTS & FORMER UST ON SITE AND NEXT DOOR (UST#6923), ANY OF WHICH MAY BE SOURCE OF PETROLEUM (UST SECTION LEAD ON
PETROLEUM ISSUE).
DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE:
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:37 DIST/DIR:0.20 SW ELEVATION:726 MAP ID:13
NAME:AMERICAN FENCE REV:6/1/12
ADDRESS:3605 S TRYON ST ID1:MO-7007
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:JAMES C. PRESSON PHONE:7045628101
SOURCE:NCDENR
Site Details Page - 47
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-7007
INCIDENT NUMBER:27713
CD NUMBER:210
REEL NUMBER:0
REGIONAL CONTACT:CBC
REGIONAL OFFICE:MOR
DATE OCCURRED:7/11/2001
RESPONSIBLE COMPANY:
AMERICAN FENCE SUPPLY COMPANY
POST OFFICE BOX 241251
CHARLOTTE ,NC , 28224
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:1
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:SOIL TO GROUNDWATER
CLOSED REVIEW REQUESTED:
CASE CLOSED:8/10/2004
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:YES
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:8/27/2004
CLEAN UP:1/1/1986
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:210
RESPONSIBLE OWNER:-1
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:37 DIST/DIR:0.20 SW ELEVATION:726 MAP ID:13
NAME:AMERICAN FENCE REV:6/1/12
ADDRESS:3605 S TRYON ST ID1:MO-7007
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:JAMES C. PRESSON PHONE:7045628101
SOURCE:NCDENR
Site Details Page - 48
RESPONSIBLE OPERATOR:-1
RESPONSIBLE LANDOWNER:-1
COMMENTS:One 1,000-gallon gasoline UST removed in 1986. ESA (2001) sampling indicates minor soil contamination and 2L exceedances. LSA
submitted using ESA data. No additional soil collection. MW-2 qualifies for LSA well. Soil analytical during ESA not complete for UST closure.
WSW survey letters not completed. WSW survey and soil boring completed. NRP for groundwater to close.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:51 DIST/DIR:0.20 SW ELEVATION:726 MAP ID:13
NAME:AMERICAN FENCE REV:6/1/12
ADDRESS:3605 S TRYON ST ID1:NCI-027713
CHARLOTTE NC 28217 ID2:27713
MECKLENBURG STATUS:CLOSED OUT
CONTACT:JAMES C. PRESSON PHONE:7045628101
SOURCE:NCDENR
Site Details Page - 49
REGIONAL UST DATA
UST NUMBER:MO-7007
INCIDENT NUMBER:27713
CD NUMBER:210
REEL NUMBER:0
REGIONAL CONTACT:CBC
REGIONAL OFFICE:MOR
DATE OCCURRED:7/11/2001
RESPONSIBLE COMPANY:
AMERICAN FENCE SUPPLY COMPANY
POST OFFICE BOX 241251
CHARLOTTE ,NC , 28224
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:1
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:SOIL TO GROUNDWATER
CLOSED REVIEW REQUESTED:
CASE CLOSED:8/10/2004
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:YES
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:8/27/2004
CLEAN UP:1/1/1986
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:210
RESPONSIBLE OWNER:-1
RESPONSIBLE OPERATOR:-1
RESPONSIBLE LANDOWNER:-1
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
RCRAGN
SEARCH ID:6 DIST/DIR:0.21 NW ELEVATION:682 MAP ID:14
NAME:ARTS ENGRAVING CO INC REV:9/11/12
ADDRESS:3136 MAY ST ID1:NCD003151701
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:VGN
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 50
- Continued on next page -
SITE INFORMATION
CONTACT INFORMATION: WAYDE CLARK
3136 MAY ST
CHARLOTTE NC 28217
PHONE: 7045235115
OWNER NAME:WILLIAM L PLEMMONS
OWNER TYPE:P-PRIVATE
OPERATOR:
OPERATOR_TYPE:
MAILING ADDRESS: PO BOX 32023
CHARLOTTE, NC 28232
UNIVERSE INFORMATION:
RECEIVED DATE:12/18/1997
SUBJECT TO CORRECTIVE ACTION (SUBJCA)
SUBJCA:N - NO
SUBJCA TSD 3004:N - NO
SUBJCA NON TSD:N - NO
SIGNIFICANT NON-COMPLIANCE(SNC):N - NO
BEGINNING OF THE YEAR SNC:
PERMIT WORKLOAD:-----
CLOSURE WORKLOAD:-----
POST CLOSURE WORKLOAD:-----
PERMITTING /CLOSURE/POST-CLOSURE PROGRESS:-----
CORRECTIVE ACTION WORKLOAD:N - NO
GENERATOR STATUS:CEG - CONDITIONALLY EXEMPT SMALL QUANTITY GENERATORS: GENERATES LESS THAN 100 KG/MONTH OF
HAZARDOUS WASTE
INSTITUTIONAL CONTROL:N-NOENGINEERING CONTROL:N
HUMAN EXPOSURE:N-NOGW CONTROLS:N- NO
LAND TYPE:P-PRIVATESHORT TERM GEN:N
TRANS FACILITY:NREC WASTE FROM OFF SITE:N
IMPORTER ACTIVITY:N - NOMIXED WASTE GEN:N - NO
TRANS ACTIVITY:N - NOTSD ACTIVITY:N - NO
RECYCLER ACTIVITY:N - NOONSITE BURNER EXEMPT:N - NO
FURNACE EXEMPTION:N - NOUNDER INJECT ACTIVITY:N - NO
REC WASTE FROM OFF SITE:N - NOUNIV WASTE DEST FAC:N
USED OIL TRANS:N - NOUSED OIL PROCESSOR:N - NO
USED OIL REFINER:N - NOUSED OIL FUEL BURNER:N - NO
UO FUEL MARKETER TO BURNER:NUSED OIL SPEC MARKETER:N - NO
NAIC INFORMATION
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
RCRAGN
SEARCH ID:6 DIST/DIR:0.21 NW ELEVATION:682 MAP ID:14
NAME:ARTS ENGRAVING CO INC REV:9/11/12
ADDRESS:3136 MAY ST ID1:NCD003151701
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:VGN
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 51
ENFORCEMENT INFORMATION:
AGENCY: STATEDATE: 97/13/1997
TYPE: WRITTEN INFORMAL
VIOLATION INFORMATION:
VIOLATION NUMBER: 1RESPONSIBLE: S - STATE
DETERMINED: 97/03/1997DETERMINED BY: S - STATE
CITATION: RESOLVED: 97/10/1997
TYPE: GENERATORS - PRE-TRANSPORT
HAZARDOUS WASTE INFORMATION:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
SPILLS80
SEARCH ID:33 DIST/DIR:0.22 SW ELEVATION:725 MAP ID:15
NAME:CANTEEN CO.REV:9/26/00
ADDRESS:3621 TRYCLAN RD ID1:6923
CHARLOTTE NC ID2:
MECKLENBURG STATUS:RESPONSE
CONTACT:CANTEEN COMPANY PHONE:
SOURCE:
Site Details Page - 52
SITE INFORMATION
OWNER/OPERATOR: CANTEEN COMPANY
MR. L. R. LENZNER
222 NORTH LASALLE STREET
CHICAGO IL 60601
DATE OF RELEASE: 8/1/89
DATE SUBMITTED: 9/17/91
DESCRIPTION OF INCIDENT: UPON REMOVAL OF UST, SOIL SAMPLES CONFIRMED CONTAMINATION.
CONTAMINATION INFORMATION
GROUNDWATER CONTAMINATED?:
MAJOR SOIL CONTAMINATION?:
MATERIAL INVOLVED (1): GASOLINE
AMOUNT LOST (1):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (2):
AMOUNT LOST (2):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (3):
AMOUNT LOST (3):
AMOUNT RECOVERED (3):
NUMBER OF WELLS AFFECTED: 0
NAME(S) OF CONTAMINATED WELLS:
PRIORITY INFORMATION:
RISK SITE?: Y
SITE PRIORITY: 060E
PRIORITY CODE: L
PRIORITY UPDATE: 5/15/98
STATUS INFORMATION:
LAST MODIFIED:
INCIDENT PHASE: RESPONSE
NOV ISSUED:
NORR ISSUED:
45 DAY REPORT:
CORRECTIVE ACTION PLAN:
CLOSURE REQ DATE:
CLOSE-OUT REPORT:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:53 DIST/DIR:0.22 SW ELEVATION:725 MAP ID:15
NAME:CANTEEN FOOD SERVICES REV:6/1/12
ADDRESS:3621 TRYCLAN RD ID1:NCI-006923
CHARLOTTE NC 28217 ID2:6923
MECKLENBURG STATUS:RESPONSE
CONTACT:L. R. LENZNER PHONE:
SOURCE:NCDENR
Site Details Page - 53
REGIONAL UST DATA
UST NUMBER:MO-3117
INCIDENT NUMBER:6923
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:DPB
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
CANTEEN CO
222 NORTH LASALLE STREET
CHICAGO ,IL , 60601
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:060E
RISK:L
RISK OF INCIDENT:I
INTERMEDIATE CONDITION:SURFACE WATER
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:8/2/1989
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:0
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:41 DIST/DIR:0.22 SW ELEVATION:724 MAP ID:16
NAME:CANTEEN CORPORATION REV:6/1/12
ADDRESS:3631 TRYCLAN DR ID1:0-014703
CHARLOTTE NC 28210 ID2:00-0-0000014703
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:CANTEEN CORPORATION PHONE:
SOURCE:NCDENR
Site Details Page - 54
SITE INFORMATION
TOTAL NUMBER OF TANKS: 1
CONTACT INFORMATION: CANTEEN CORPORATION
3631 TRYCLAN DRIVE
CHARLOTTE NC 28210
TANK NUMBER: 1
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Gasoline, Gas Mix
CAPACITY IN GALLONS: 8000
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
ARCHIVED INFORMATION AS OF 2011
TANK NUMBER: 1
INSTALLATION DATE: 19690601
CLOSED DATE: 19890331
STATUS: PERMANENTLY CLOSED
CONTENTS: GASOLINE, GASOLINE MIXTURE
CAPACITY IN GALLONS: 8000
COMMENTS:
CONSTRUCTION MATERIAL: STEEL
INTERIOR: UNKNOWN
EXTERIOR: PAINT
CORROSION PROTECTION:
LEAK DETECTION:
PIPING MATERIAL: STEEL
PIPE CORROSION PROTECTION:
PIPE LEAK DETECTION:
OVERFLOW PROTECTION:
FINANCIAL RESPONSIBILITY:
CERTIFICATION TYPE:
GPS SITING CONFIRMED:N
PERSON CONFIRMING:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:42 DIST/DIR:0.22 SW ELEVATION:724 MAP ID:16
NAME:CANTEEN FOOD SERVICES REV:6/1/12
ADDRESS:3631 TRYCLAN DR ID1:MO-3117
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:L. R. LENZNER PHONE:
SOURCE:NCDENR
Site Details Page - 55
- Continued on next page -
SITE INFORMATION
REGIONAL UST DATA
UST NUMBER:MO-3117
INCIDENT NUMBER:6923
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:DPB
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
CANTEEN CO
222 NORTH LASALLE STREET
CHICAGO ,IL , 60601
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:060E
RISK:L
RISK OF INCIDENT:I
INTERMEDIATE CONDITION:SURFACE WATER
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:8/2/1989
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:0
RESPONSIBLE OWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:42 DIST/DIR:0.22 SW ELEVATION:724 MAP ID:16
NAME:CANTEEN FOOD SERVICES REV:6/1/12
ADDRESS:3631 TRYCLAN DR ID1:MO-3117
CHARLOTTE NC 28217 ID2:
MECKLENBURG STATUS:UNKNOWN
CONTACT:L. R. LENZNER PHONE:
SOURCE:NCDENR
Site Details Page - 56
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
COMMENTS:1-8000-gallon DIESEL UST (old Coor 35.1228 80.5241)-benzene and xylenes in g water so low boiling pts assigned to ranking
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:46 DIST/DIR:0.22 SE ELEVATION:751 MAP ID:17
NAME:F N THOMPSON INC REV:6/1/12
ADDRESS:201 CLANTON RD ID1:0-002592
CHARLOTTE NC 28232 ID2:00-0-0000002592
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:F N THOMPSON INC PHONE:
SOURCE:NCDENR
Site Details Page - 57
- Continued on next page -
SITE INFORMATION
TOTAL NUMBER OF TANKS: 5
CONTACT INFORMATION: F N THOMPSON INC
201 CLANTON ROAD
CHARLOTTE NC 28232
TANK NUMBER: 001
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Diesel
CAPACITY IN GALLONS: 5000
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
TANK NUMBER: 002
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Diesel
CAPACITY IN GALLONS: 3000
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
TANK NUMBER: 003
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Gasoline, Gas Mix
CAPACITY IN GALLONS: 8000
TANK CONSTRUCTION:3
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:46 DIST/DIR:0.22 SE ELEVATION:751 MAP ID:17
NAME:F N THOMPSON INC REV:6/1/12
ADDRESS:201 CLANTON RD ID1:0-002592
CHARLOTTE NC 28232 ID2:00-0-0000002592
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:F N THOMPSON INC PHONE:
SOURCE:NCDENR
Site Details Page - 58
- Continued on next page -
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
TANK NUMBER: 004
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Oil, New/Used/Mix
CAPACITY IN GALLONS: 550
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
TANK NUMBER: 005
ROOT TANK ID:
TANK STATUS:
INSTALLATION DATE:
PERM CLOSED:
CONTENTS: Diesel
CAPACITY IN GALLONS: 4000
TANK CONSTRUCTION:3
PIPE CONSTRUCTION:4
MAIN TANK:NO
COMPARTMENT TANK:NO
MANIFOLD TANK:
COMMERCIAL TANK:YES
REGULATED TANK:YES
REGIONAL UST DATA
UST NUMBER:MO-0901
INCIDENT NUMBER:
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
UST
SEARCH ID:46 DIST/DIR:0.22 SE ELEVATION:751 MAP ID:17
NAME:F N THOMPSON INC REV:6/1/12
ADDRESS:201 CLANTON RD ID1:0-002592
CHARLOTTE NC 28232 ID2:00-0-0000002592
MECKLENBURG STATUS:PERM CLOSED REMOVED
CONTACT:F N THOMPSON INC PHONE:
SOURCE:NCDENR
Site Details Page - 59
- More Details Exist For This Site; Max Page Limit Reached -
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:
RISK OF INCIDENT:
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:0
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
COMMENTS:NO UST CLOSURE RECEIVED
ARCHIVED INFORMATION AS OF 2011
TANK NUMBER: 001
INSTALLATION DATE: 19560512
CLOSED DATE: 19900415
STATUS: PERMANENTLY CLOSED
CONTENTS: DIESEL, DIESEL MIXTURE
CAPACITY IN GALLONS: 5000
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:55 DIST/DIR:0.27 SE ELEVATION:762 MAP ID:18
NAME:CATS MAINTENANCE FACITLITY REV:6/1/12
ADDRESS:3200 SOUTH BLVD ID1:NCI-027904
CHARLOTTE NC 28209 ID2:27904
MECKLENBURG STATUS:CLOSED OUT
CONTACT:FRANK WARD PHONE:
SOURCE:NCDENR
Site Details Page - 60
REGIONAL UST DATA
UST NUMBER:MO-7219
INCIDENT NUMBER:27904
CD NUMBER:256
REEL NUMBER:0
REGIONAL CONTACT:BLM
REGIONAL OFFICE:MOR
DATE OCCURRED:4/14/2005
RESPONSIBLE COMPANY:
CHARLOTTE AREA TRANSIT SERVICE
4701 HEDGEMOR DRIVE SUITE 810
CHARLOTTE ,NC , 28209
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:NON COMMERCIAL
REGULATED:NON REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:SOIL TO GROUNDWATER
CLOSED REVIEW REQUESTED:
CASE CLOSED:7/1/2005
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:4/14/2005
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:HEATING OIL
CD NUMBER:256
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:-1
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:15 DIST/DIR:0.30 SE ELEVATION:755 MAP ID:19
NAME:CITY OF CHARLOTTE-SCALEYBARK SITE REV:6/8/12
ADDRESS:3610 SOUTH BLVD ID1:NONCD0002805
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 61
SITE INFORMATION
DATE ADDED: 6/16/2008RESIDENCE ON SITE: NO
DW WELL DISTANCE: > 1/4 MILESW INTAKE DISTANCE: NO INFO
PROCESS CODE: MF
MEDIA CONTAMINATEDCONTAMINANT TYPE
SOILORGANICS
SOILMETALS
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:57 DIST/DIR:0.30 NW ELEVATION:721 MAP ID:20
NAME:CONOCO STORE #33066 REV:6/1/12
ADDRESS:605 CLANTON RD ID1:NCI-011918
CHARLOTTE NC 28217 ID2:11918
MECKLENBURG STATUS:CLOSED OUT
CONTACT:MR. PAUL TAYLOR PHONE:
SOURCE:NCDENR
Site Details Page - 62
REGIONAL UST DATA
UST NUMBER:MO-4037
INCIDENT NUMBER:11918
CD NUMBER:73
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:1/5/1994
RESPONSIBLE COMPANY:
CONOCOPHILLIPS
PO BOX 4784
HOUSTON ,TX , 772104784
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:3/22/1994
VIOLATION:2/14/1995
PHASE REQUIRED:
SITE PRIORITY:060E
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:8/7/2000
CASE CLOSED:1/12/2001
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:1/5/1994
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:73
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:68 DIST/DIR:0.33 NE ELEVATION:750 MAP ID:21
NAME:PEPSI-COLA REV:6/1/12
ADDRESS:3101 GRIFFITH ST ID1:NCI-009747
CHARLOTTE NC 28203 ID2:9747
MECKLENBURG STATUS:CLOSED OUT
CONTACT:MR. STU MENTZEL PHONE:
SOURCE:NCDENR
Site Details Page - 63
REGIONAL UST DATA
UST NUMBER:MO-3731
INCIDENT NUMBER:9747
CD NUMBER:79
REEL NUMBER:0
REGIONAL CONTACT:MT
REGIONAL OFFICE:MOR
DATE OCCURRED:12/2/1991
RESPONSIBLE COMPANY:
PEPSI-COLA
3101 GRIFFITH STREET
CHARLOTTE ,NC , 28203
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:E
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:10/22/2001
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:12/2/1991
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:OTHER PETROLEUM PROD.
CD NUMBER:79
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:70 DIST/DIR:0.33 NE ELEVATION:751 MAP ID:22
NAME:SERVCO #01613 REV:6/1/12
ADDRESS:3040 SOUTH BLVD ID1:NCI-027648
CHARLOTTE NC 28209 ID2:27648
MECKLENBURG STATUS:CURRENT RECORD
CONTACT:STEVE SAUNDERS PHONE:7049822197
SOURCE:NCDENR
Site Details Page - 64
REGIONAL UST DATA
UST NUMBER:MO-6930
INCIDENT NUMBER:27648
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:DPB
REGIONAL OFFICE:MOR
DATE OCCURRED:1/9/2004
RESPONSIBLE COMPANY:
SERVCO DISTRIBUTING COMPANY
PO BOX 310
ALBEMARLE ,NC , 28001
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:2
SITE PRIORITY:
RISK:I
RISK OF INCIDENT:I
INTERMEDIATE CONDITION:GROSS CONTAMINENT
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:YES
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:6/21/2004
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:0
RESPONSIBLE OWNER:-1
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:71 DIST/DIR:0.33 NE ELEVATION:751 MAP ID:22
NAME:SERVCO STATION/S. BLVD REV:6/1/12
ADDRESS:3040 SOUTH BLVD ID1:NCI-008796
CHARLOTTE NC 28209 ID2:8796
MECKLENBURG STATUS:CLOSED OUT
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 65
REGIONAL UST DATA
UST NUMBER:MO-3536
INCIDENT NUMBER:8796
CD NUMBER:2
REEL NUMBER:0
REGIONAL CONTACT:MT
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:8/28/1991
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:8/12/1991
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:
CD NUMBER:2
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
NFRAP
SEARCH ID:4 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23
NAME:WILLIARD SMELTING CO.REV:8/1/12
ADDRESS:101 NEW BERN ST ID1:NCD003151651
CHARLOTTE NC 28203 ID2:0402603
MECKLENBURG STATUS:NFRAP-N
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 66
DESCRIPTION:
ACTION/QUALITY AGENCY/RPS START/RAA END
ARCHIVE SITEEPA In-House3/12/1987
SITE REASSESSMENTState, Fund Financed6/14/2005
NFRAP: NO FURTHER REMEDIAL ACTION PLANNED
DISCOVERYEPA Fund-Financed6/6/1985
PRELIMINARY ASSESSMENTState, Fund Financed5/15/1986
LOW PRIORITY FOR FURTHER ASSESSMENT
SITE INSPECTIONState, Fund Financed3/12/1987
NFRAP: NO FURTHER REMEDIAL ACTION PLANNED
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:28 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23
NAME:WILLARD SMELTING CO.REV:6/8/12
ADDRESS:101 NEW BERN ST ID1:NCD003151651
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 67
SITE INFORMATION
EPA ID:NCD003151651INCIDENT ID:85678
REP DISCOVERY DATE:15-MAY-01NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:
INCIDENT COMMENTS:NO FILE AT MRO. INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO. 10/05:
Apparently this site is going into the brownfields program.
DATE ADDED: 1/12/1988RESIDENCE ON SITE: NO
DW WELL DISTANCE: > 1/4 MILESW INTAKE DISTANCE: NO INFO
PROCESS CODE: BATTERY DUMPING/MANUFACTURING - BATTERY BREAKING-LEAD RECOVERY OPERATIONS OR CASING DISPOSAL
ACTIVITIES AND BATTERY MANUFACTURING
MEDIA CONTAMINATEDCONTAMINANT TYPE
SOILMETALS
SITE CATEGORIES
SPL SCORE: 27.86SPL: YES
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:75 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23
NAME:WILLARD INDUSTRIES (FORMER)REV:6/1/12
ADDRESS:101 NEW BERN ST ID1:NCI-017690
CHARLOTTE NC 28203 ID2:17690
MECKLENBURG STATUS:CLOSED OUT
CONTACT:C/O LOYD CAUDLE PHONE:704-377-1200
SOURCE:NCDENR
Site Details Page - 68
REGIONAL UST DATA
UST NUMBER:MO-5173
INCIDENT NUMBER:17690
CD NUMBER:290
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:8/19/1996
RESPONSIBLE COMPANY:
NEW BERN REALTY COMPANY
2660 INTERST. TWR,121 W. TRADE
CHARLOTTE ,NC , 28202
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:1
SITE PRIORITY:20E
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:SOIL TO GROUNDWATER
CLOSED REVIEW REQUESTED:
CASE CLOSED:7/19/2006
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:NO
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:8/3/2006
CLEAN UP:8/19/1996
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:290
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:-1
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:76 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23
NAME:WILLARD SMELTING CO REV:10/1/01
ADDRESS:101 NEW BERN ST ID1:NCI-085678
CHARLOTTE NC ID2:
MECKLENBURG STATUS:NOD
CONTACT: PHONE:
SOURCE:
Site Details Page - 69
OWNER/OPERATOR:
DATE OF RELEASE:
DATE SUBMITTED: 5/15/2001
DESCRIPTION OF INCIDENT: NO FILE AT MRO. INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO.
CONTAMINATION INFORMATION
GROUNDWATER CONTAMINATED?: NOD
MAJOR SOIL CONTAMINATION?:
MATERIAL INVOLVED (1):
AMOUNT LOST (1):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (2):
AMOUNT LOST (2):
AMOUNT RECOVERED (2):
MATERIAL INVOLVED (3):
AMOUNT LOST (3):
AMOUNT RECOVERED (3):
NUMBER OF WELLS AFFECTED: 0
NAME(S) OF CONTAMINATED WELLS:
PRIORITY INFORMATION:
RISK SITE?:
SITE PRIORITY:
PRIORITY CODE:
PRIORITY UPDATE:
STATUS INFORMATION:
LAST MODIFIED:
INCIDENT PHASE: NOD
NOV ISSUED:
NORR ISSUED:
45 DAY REPORT:
CORRECTIVE ACTION PLAN:
CLOSURE REQ DATE:
CLOSE-OUT REPORT:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:84 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23
NAME:WILLARD LEAD FACILITY REV:8/10/12
ADDRESS:101 NEW BERN ST ID1:NCBR-0206-087
CHARLOTTE NC ID2:09044-05-60
MECKLENBURG STATUS:FINALIZED
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 70
SITE INFORMATION
PROSPECTIVE DEVELOPER:HARRIS MURR & VERMILLION, LLC
FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS
DESCRIPTION:Groundwater at the approximately 4.5-acre site is contaminated with chlorinated solvents, while soil shows metals contamination.
The majority of the property has been vacant since 1996, the PD intends to redevelop the property into residential, retail, and possibly other
commercial uses.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
NFRAP
SEARCH ID:1 DIST/DIR:0.36 NE ELEVATION:752 MAP ID:24
NAME:BORDEN CHEMICAL PRINTING INK REV:8/1/12
ADDRESS:3013 GRIFFITH ST ID1:NCD049774375
CHARLOTTE NC 28203 ID2:0402783
MECKLENBURG STATUS:NFRAP-N
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 71
DESCRIPTION:
ACTION/QUALITY AGENCY/RPS START/RAA END
ARCHIVE SITEEPA In-House2/5/1991
DISCOVERYEPA Fund-Financed8/1/1980
PRELIMINARY ASSESSMENTState, Fund Financed9/18/1985
LOW PRIORITY FOR FURTHER ASSESSMENT
SITE INSPECTIONEPA Fund-Financed2/5/1991
NFRAP: NO FURTHER REMEDIAL ACTION PLANNED
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:13 DIST/DIR:0.36 NE ELEVATION:752 MAP ID:24
NAME:BORDEN CHEMICAL PRINTING INK REV:6/8/12
ADDRESS:3013 GRIFFITH ST ID1:NCD049774375
CHARLOTTE NC ID2:
MECKLENBURG STATUS:NFA
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 72
SITE INFORMATION
DATE ADDED: 1/12/1988RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: PAINTING & PRINTING - PAINTING AND PRINTING OPERATIONS WITH THE EXCEPTION OF FURNITURE FINISHING; ALSO
INCLUDES PAINT MANUFACTURE AND BLENDING OPERATIONS
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: YES
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
NFRAP
SEARCH ID:2 DIST/DIR:0.36 NE ELEVATION:727 MAP ID:25
NAME:PIEDMONT HEAT TREATING CORP REV:8/1/12
ADDRESS:3311 GRIFFITH ST ID1:NCD066309113
CHARLOTTE NC 28203 ID2:0402850
MECKLENBURG STATUS:NFRAP-N
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 73
DESCRIPTION:
ACTION/QUALITY AGENCY/RPS START/RAA END
ARCHIVE SITEEPA In-House3/26/1990
DISCOVERYEPA Fund-Financed1/1/1984
PRELIMINARY ASSESSMENTState, Fund Financed7/18/1986
LOW PRIORITY FOR FURTHER ASSESSMENT
SITE INSPECTIONEPA Fund-Financed3/26/1990
NFRAP: NO FURTHER REMEDIAL ACTION PLANNED
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:21 DIST/DIR:0.36 NE ELEVATION:727 MAP ID:25
NAME:PIEDMONT HEAT TREATING CORP REV:6/8/12
ADDRESS:3311 GRIFFITH ST ID1:NCD066309113
CHARLOTTE NC ID2:
MECKLENBURG STATUS:NFA
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 74
SITE INFORMATION
DATE ADDED: 1/12/1988RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: MF
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: YES
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:59 DIST/DIR:0.37 NE ELEVATION:738 MAP ID:26
NAME:EPMORE INC.REV:6/1/12
ADDRESS:2941 S TRYON ST ID1:NCI-015304
CHARLOTTE NC 28203 ID2:15304
MECKLENBURG STATUS:RESPONSE
CONTACT:WILLAIM MOORE PHONE:
SOURCE:NCDENR
Site Details Page - 75
REGIONAL UST DATA
UST NUMBER:MO-4573
INCIDENT NUMBER:15304
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:DPB
REGIONAL OFFICE:MOR
DATE OCCURRED:2/2/1990
RESPONSIBLE COMPANY:
EPMORE INC.
PO BOX 36094
CHARLOTTE ,NC , 28236
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:E
RISK:L
RISK OF INCIDENT:U
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:2/2/1990
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:0
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:83 DIST/DIR:0.38 NE ELEVATION:726 MAP ID:27
NAME:RUSAK PROPERTY REV:3/31/08
ADDRESS:3004 BANK ST ID1:NCBR-0038
CHARLOTTE NC ID2:
MECKLENBURG STATUS:FINALIZED
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 76
HISTORIC INFORMATIONA 1.21-acre parcel that is adjacent to the Marie G. Davis Middle School. The site is contaminated from historical
operations as a metal plating facility. The PD intends to incorporate the adjacent parcels into the new middle school construction. The brownfields
parcel will be the plaza entrance.
SITE INFORMATION
PROSPECTIVE DEVELOPER:CharMeck Board of Education
FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS
DESCRIPTION:A 1.21-acre parcel that is adjacent to the Marie G. Davis Middle School. The site is contaminated from historical operations as a
metal plating facility. The PD intends to incorporate the adjacent parcels into the new middle school construction. The brownfields parcel will be the
plaza entrance.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:19 DIST/DIR:0.38 NE ELEVATION:759 MAP ID:28
NAME:NIVENS PROPERTY REV:6/8/12
ADDRESS:3022 GRIFFITH ST ID1:NONCD0002204
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 77
SITE INFORMATION
EPA ID:NONCD0002204INCIDENT ID:86905
REP DISCOVERY DATE:21-JAN-04NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:AFFIDAVIT
INCIDENT COMMENTS:LOW LEVEL OF TCE & CHLOROFORM DISCOVERD IN MONITORING WELLS DURING ENVIRONMENTAL SITE
ASSESSMENT. SOURCE UNKNOWN AT THIS TIME. WAITING ON RESPONSE FROM AFFIDAVIT TO PROPOERTY OWNER.
DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE:
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:60 DIST/DIR:0.38 NE ELEVATION:759 MAP ID:28
NAME:FLOORING CONCEPTS REV:6/1/12
ADDRESS:3022 GRIFFITH ST ID1:NCI-027262
CHARLOTTE NC 28203 ID2:27262
MECKLENBURG STATUS:CLOSED OUT
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 78
REGIONAL UST DATA
UST NUMBER:MO-1299
INCIDENT NUMBER:27262
CD NUMBER:24
REEL NUMBER:0
REGIONAL CONTACT:MT
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:8/7/1991
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:8/5/1991
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:24
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:82 DIST/DIR:0.38 NE ELEVATION:711 MAP ID:29
NAME:RUSAK PROPERTY REV:8/10/12
ADDRESS:3331 GRIFFITH ST ID1:NCBF-0811-003
CHARLOTTE NC ID2:07020-03-60
MECKLENBURG STATUS:FINALIZED
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 79
SITE INFORMATION
PROSPECTIVE DEVELOPER:CHARMECK BOARD OF EDUCATION
FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS
DESCRIPTION:A 1.21-acre parcel that is adjacent to the Marie G. Davis Middle School. The site is contaminated from historical operations as a
metal plating facility. The PD intends to incorporate the adjacent parcels into the new middle school construction. The brownfields parcel will be the
plaza entrance.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:64 DIST/DIR:0.40 NE ELEVATION:760 MAP ID:30
NAME:MRS. J. SPENCER BELL/WF (RP-D)REV:6/1/12
ADDRESS:111 NEW BERN ST ID1:NCI-005176
CHARLOTTE NC 28203 ID2:5176
MECKLENBURG STATUS:RESPONSE
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 80
REGIONAL UST DATA
UST NUMBER:MO-2887
INCIDENT NUMBER:5176
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:DPB
REGIONAL OFFICE:MOR
DATE OCCURRED:6/25/1989
RESPONSIBLE COMPANY:
` DECEASED MRS J. SPENSER BELL
DECEASED
DECEASED ,DE ,
SOURCE:LEAK, UST
PETROLEUM TYPE:NON PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:040E
RISK:L
RISK OF INCIDENT:U
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:6/25/1989
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:
POLLUTANT TYPE:
CD NUMBER:0
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:77 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31
NAME:BROWN S SOLVENT CO REV:9/30/10
ADDRESS:2935 GRIFFITH ST ID1:NCBR-0010
CHARLOTTE NC ID2:
MECKLENBURG STATUS:FINALIZED
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 81
SITE INFORMATION
PROSPECTIVE DEVELOPER:KATHRYN C BELL ESTATE
FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS
DESCRIPTION:Former paint and solvent formulation facility with known solvent-impacted soil and groundwater. PD intends to initially renovate &
reuse the existing structure for office/warehouse use, and ultimately raze the building and redevelop the site as a mixed office/retail complex in
keeping with other redevelopment taking place in Charlotte s South End.
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:78 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31
NAME:BROWN S SOLVENT CO.REV:8/10/12
ADDRESS:2935 GRIFFITH ST ID1:05006-01-60
CHARLOTTE NC ID2:05006-01-60
MECKLENBURG STATUS:FINALIZED
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 82
SITE INFORMATION
PROJECT NUMBER:05006-01-60
For more information please contact the NCDENR at (919) 707-8383
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
FEDBROWNFIELD
SEARCH ID:86 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31
NAME:BROWN S SOLVENT COMPANY REV:10/1/08
ADDRESS:2935 GRIFFITH ST ID1:55781569-16
CHARLOTTE NC ID2:13562
MECKLENBURG STATUS:EPA BROWNFIELD
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 83
- Continued on next page -
SITE INFORMATION:
RECIPIENT NAME:CHARLOTTE, CITY OF
GRANT PROJ NAME:CHARLOTTE, NC
CURRENT USE:
FUTURE USE:
PAST USAGE TYPE:
FUTURE USAGE TYPE:
START DATE:9/30/2004
COMPLETION DATE:9/30/2004
CLEANUP REQUIRED:
ACCOMP TYPE:PHASE I ENVIRONMENTAL ASSESSMENT
ACCOMP AMOUNT(ACRES):
PROPERTY ID:13562PROPRETY SIZE:0.6
PARCEL NUMBER:147-017-06
CURRENT OWNER:OWNER ENTITY:
CONTAMINATION FOUND
PETROLEUM PROD:CONTROLLED SUB:
ASBESTOS:PCBS:
VOCS:LEAD:
OTHER METALS:PAHS:
OTHER:NONE:
UNKNOWN:
MEDIA FOUND
SOIL:AIR:
SURFACE WATER:GROUND WATER:
DRINKING WATER:SEDIMENTS:
CONTAMINANTS CLEANED UP
PETROLEUM:CONTROLLED SUB:
ASBESTOS:PCB:
VOC:LEAD:
OTHER METAL:PAHS:
OTHER:UNKNOWN:
NONE:
MEDIA CLEANED UP
SOIL:AIR:
SURFACE WATER:GROUND WATER:
DRINKING WATER:SEDIMENTS:
UNKNOWN:NONE:
STATE/TRIBAL PROG ID:
STATE/TRIBE PROG ENROLL:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
FEDBROWNFIELD
SEARCH ID:86 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31
NAME:BROWN S SOLVENT COMPANY REV:10/1/08
ADDRESS:2935 GRIFFITH ST ID1:55781569-16
CHARLOTTE NC ID2:13562
MECKLENBURG STATUS:EPA BROWNFIELD
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 84
NOT ENROLLED:
NFA ISSUE DATE:
IC REQUIRED:
IC IN PLACE:U
IC IN PLACE DATE:
PROPRIETARY CONTROLS:
GOVERNMENTAL CONTROLS:
ENFORCE PERM TOOLS:
INFORM DEVICES:
IC DATA ADDRESS:
PHOTO AVAIL:
VIDEO AVAIL:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
FEDBROWNFIELD
SEARCH ID:87 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31
NAME:BROWN S SOLVENT COMPANY REV:5/1/12
ADDRESS:2935 GRIFFITH ST ID1:13562
CHARLOTTE NC 28203 ID2:13562
MECKLENBURG STATUS:EPA BROWNFIELD
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 85
- Continued on next page -
SITE INFORMATION:
Y= YES N=NO U=UNKNOWN
GRANT RECIPIENT:CHARLOTTE, CITY OF
TYPE OF GRANT:ASSESSMENT
TYPE OF FUNDING:N/A
ACRES PROPERTY ID:13562
PROPERTY SIZE (ACRES):.6
LOCAL PROPERTY NUMBER:147-017-06
OWNERSHIP ENTITTY:
CURRENT OWNER:
DID OWNERSHIP CHANGE:
SUPERFUND LANDOWNER LIABILITY CHANGE:
PAST USE GREENSPACE (ACRES):
PAST USE RESIDENTIAL(ACRES):
PAST USE COMMERCIAL (ACRES):
PAST USE INDUSTRIAL (ACRES):
CONTAMINATION FOUND
PETROLEUM:CONTROLLED SUBSTANCES:
ASBESTOS:PCBs:
VOCs:LEAD:
OTHER METALS:PAHs:
OTHER:
OTHER DESCRIPTION:
CONTAMINATION CLEANED UP:
CLEANUP REQUIRED:
PETROLEUM:CONTROLLED SUBSTANCES:
ASBESTOS:PCBs:
VOCs:LEAD:
OTHER METALS:PAHs:
OTHER:
OTHER DESCRIPTION:
MEDIA AFFECTED
SOIL:AIR:
SURFACE WATER:GROUND WATER:
DRINKING WATER:SEDIMENTS:
NO MEDIA:UNKNOWN:
MEDIA CLEANED:
SOIL:AIR:
SURFACE WATER:GROUND WATER:
DRINKING WATER:SEDIMENTS:
STATE OR TRIBAL PROGRAM:STATE/TRIBAL ID:
NFA/CLEANUP COMPL ISSUED:DATE ENROLLED IN PROG:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
FEDBROWNFIELD
SEARCH ID:87 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31
NAME:BROWN S SOLVENT COMPANY REV:5/1/12
ADDRESS:2935 GRIFFITH ST ID1:13562
CHARLOTTE NC 28203 ID2:13562
MECKLENBURG STATUS:EPA BROWNFIELD
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 86
INSTITUTIONAL CONTROL INFORMATION (IC)
IC REQUIRED:PROPERTY CONTROLS:
INFORMATIONAL DEVICES:GOVERNMENTAL CONTROLS:
ENFORCEMENT/PERMIT TOOLS:IC IN PLACE:U
DATE IC IN PLACE:
CLEANUP START DATE:CLEANUP COMPLETION:
ACRES CLEANED UP:CLEANUP FUNDING SOURCE:
PROVIDING CLEANUP FUNDS:AMOUNT OF FUNDING:
REDEVELOP START:
FUTURE USE (acres)
GREEN SPACE:RESIDENTIAL:
COMMERCIAL:INDUSTRIAL:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
BROWNFIELD
SEARCH ID:85 DIST/DIR:0.40 NE ELEVATION:759 MAP ID:32
NAME:WILLARD LEAD RIGHT-OF-WAY REV:8/10/12
ADDRESS:122 NEW BERN ST ID1:15014-11-60
CHARLOTTE NC ID2:15014-11-60
MECKLENBURG STATUS:FINALIZED
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 87
SITE INFORMATION
PROJECT NUMBER:15014-11-60
For more information please contact the NCDENR at (919) 707-8383
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:58 DIST/DIR:0.42 SE ELEVATION:752 MAP ID:33
NAME:DIXIE WRECKER REV:6/1/12
ADDRESS:3801 SOUTH BLVD ID1:NCI-036241
CHARLOTTE NC 28217 ID2:36241
MECKLENBURG STATUS:CURRENT RECORD
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 88
REGIONAL UST DATA
UST NUMBER:MO-2069
INCIDENT NUMBER:36241
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:DPB
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:INDUSTRIAL/COMMERCIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:YES
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:0
RESPONSIBLE OWNER:-1
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
NFRAP
SEARCH ID:3 DIST/DIR:0.43 NE ELEVATION:762 MAP ID:34
NAME:SWIFT ADHESIVES & COATINGS REV:8/1/12
ADDRESS:2917 YOUNGBLOOD ST ID1:NCD980557763
CHARLOTTE NC 28203 ID2:0403025
MECKLENBURG STATUS:NFRAP-N
CONTACT: PHONE:
SOURCE:EPA
Site Details Page - 89
DESCRIPTION:
ACTION/QUALITY AGENCY/RPS START/RAA END
ARCHIVE SITEEPA In-House9/9/1987
DISCOVERYEPA Fund-Financed6/1/1981
PRELIMINARY ASSESSMENTState, Fund Financed9/9/1987
NFRAP: NO FURTHER REMEDIAL ACTION PLANNED
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:25 DIST/DIR:0.43 NE ELEVATION:762 MAP ID:34
NAME:SWIFT ADHESIVES & COATINGS/CHARLOTTE REV:6/8/12
ADDRESS:2917 YOUNGBLOOD ST ID1:NCD980557763
CHARLOTTE NC ID2:
MECKLENBURG STATUS:NFA
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 90
SITE INFORMATION
DATE ADDED: 1/12/1988RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: PAINTING & PRINTING - PAINTING AND PRINTING OPERATIONS WITH THE EXCEPTION OF FURNITURE FINISHING; ALSO
INCLUDES PAINT MANUFACTURE AND BLENDING OPERATIONS
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: YES
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:27 DIST/DIR:0.43 NE ELEVATION:748 MAP ID:35
NAME:TERRELL MACHINE SHOP REV:6/8/12
ADDRESS:3000 SOUTH BLVD ID1:NONCD0000011
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 91
SITE INFORMATION
EPA ID:NONCD0000011INCIDENT ID:5015
REP DISCOVERY DATE:24-APR-89NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:MONITOR REPORT
INCIDENT COMMENTS:CHLORINATED SOLVENTS, OFF-SITE PETRO. CONT.?;SELF-INITIATED REM. IN PLACE AND MONITORING. 2002:
ACCEPTED INTO BROWNFIELDS PROGRAM.
DATE ADDED: 3/9/1990RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: MF
MEDIA CONTAMINATEDCONTAMINANT TYPE
SOILORGANICS
GROUNDWATERORGANICS
SITE CATEGORIES
SPL SCORE: 39.62SPL: YES
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:73 DIST/DIR:0.43 NE ELEVATION:748 MAP ID:35
NAME:TERRELL MACHINE COMPANY REV:10/1/01
ADDRESS:0 P. O. BOX 240868 ID1:NCI-005015
CHARLOTTE NC ID2:
MECKLENBURG STATUS:RESPONSE
CONTACT:A. E. TERRELL PHONE:
SOURCE:
Site Details Page - 92
OWNER/OPERATOR: A. E. TERRELL
TERRELL MACHINE COMPANY
1515 MOCKINGBIRD LANE
CHARLOTTE NC
DATE OF RELEASE: 4/24/1989
DATE SUBMITTED: 4/27/1989
DESCRIPTION OF INCIDENT: CHLORINATED SOLVENTS, OFF-SITE PETRO. CONT.?;SELF-INITIATED REM. IN PLACE AND MONITORING. 2002:
ACCEPTED INTO BROWNFIELDS PROGRAM.
CONTAMINATION INFORMATION
GROUNDWATER CONTAMINATED?: Y
MAJOR SOIL CONTAMINATION?:
MATERIAL INVOLVED (1):
AMOUNT LOST (1):
AMOUNT RECOVERED (1):
MATERIAL INVOLVED (2):
AMOUNT LOST (2):
AMOUNT RECOVERED (2):
MATERIAL INVOLVED (3):
AMOUNT LOST (3):
AMOUNT RECOVERED (3):
NUMBER OF WELLS AFFECTED: 0
NAME(S) OF CONTAMINATED WELLS:
PRIORITY INFORMATION:
RISK SITE?:
SITE PRIORITY: 80
PRIORITY CODE: E
PRIORITY UPDATE:
STATUS INFORMATION:
LAST MODIFIED:
INCIDENT PHASE: RESPONSE
NOV ISSUED:
NORR ISSUED:
45 DAY REPORT:
CORRECTIVE ACTION PLAN:
CLOSURE REQ DATE:
CLOSE-OUT REPORT:
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:72 DIST/DIR:0.43 NE ELEVATION:754 MAP ID:36
NAME:SUMMERFIELD S AUTO REV:6/1/12
ADDRESS:3017 SOUTH ID1:NCI-005261
CHARLOTTE NC 28209 ID2:5261
MECKLENBURG STATUS:RESPONSE
CONTACT:MS. MARTHA REID/MR REID-DECEAS PHONE:
SOURCE:NCDENR
Site Details Page - 93
REGIONAL UST DATA
UST NUMBER:MO-2899
INCIDENT NUMBER:5261
CD NUMBER:287
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
THE CUPBOARD, INC.
811 HILLSIDE AVENUE
CHARLOTTE ,NC , 28209
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:11/14/1989
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:110D
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:GROSS CONTAMINENT
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:RESIDENTIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:9/14/2006
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:YES
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:10/10/2006
CLEAN UP:4/21/1989
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:287
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:14 DIST/DIR:0.44 NE ELEVATION:755 MAP ID:37
NAME:CHARLOTTE BATTERY REV:6/8/12
ADDRESS:2926 YOUNGBLOOD ST ID1:NONCD0001150
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 94
SITE INFORMATION
DATE ADDED: 12/6/2005RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: BATTERY DUMPING/MANUFACTURING - BATTERY BREAKING-LEAD RECOVERY OPERATIONS OR CASING DISPOSAL
ACTIVITIES AND BATTERY MANUFACTURING
MEDIA CONTAMINATEDCONTAMINANT TYPE
KNOWN/SUSPECTED
SITE CATEGORIES
SPL SCORE: 33.67SPL: YES
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:52 DIST/DIR:0.45 SE ELEVATION:754 MAP ID:38
NAME:C.M. ALLEN CONSTUCTION REV:6/1/12
ADDRESS:3813 SOUTH BLVD ID1:NCI-008582
CHARLOTTE NC 28209 ID2:8582
MECKLENBURG STATUS:RESPONSE
CONTACT:MR. BILL JOHNS PHONE:
SOURCE:NCDENR
Site Details Page - 95
REGIONAL UST DATA
UST NUMBER:MO-3407
INCIDENT NUMBER:8582
CD NUMBER:320
REEL NUMBER:0
REGIONAL CONTACT:BLM
REGIONAL OFFICE:MOR
DATE OCCURRED:2/20/1991
RESPONSIBLE COMPANY:
NISBET OIL COMPANY
PO BOX 35367
CHARLOTTE ,NC , 28235
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:E?
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:RESIDENTIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:1/16/2007
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:YES
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:1/23/2007
CLEAN UP:2/20/1991
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:320
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:63 DIST/DIR:0.47 SE ELEVATION:750 MAP ID:39
NAME:MEJIA AUTOMOTIVE PROPERTY REV:6/1/12
ADDRESS:3821 SOUTH BLVD ID1:NCI-036617
CHARLOTTE NC 28209 ID2:36617
MECKLENBURG STATUS:ARCHIVED
CONTACT:UNKNOWN PHONE:
SOURCE:NCDENR
Site Details Page - 96
REGIONAL UST DATA
UST NUMBER:MO-8009
INCIDENT NUMBER:36617
CD NUMBER:393
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:6/30/2008
RESPONSIBLE COMPANY:
UNKNOWN
,NC ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:1
SITE PRIORITY:
RISK:U
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:SOIL TO GROUNDWATER
CLOSED REVIEW REQUESTED:
CASE CLOSED:1/28/2009
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:NO
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:2/5/2009
CLEAN UP:
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:OTHER PETROLEUM PROD.
CD NUMBER:393
RESPONSIBLE OWNER:-1
RESPONSIBLE OPERATOR:-1
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:62 DIST/DIR:0.48 NE ELEVATION:749 MAP ID:40
NAME:KRISPY KREME DOUGHNUT REV:6/1/12
ADDRESS:2901 SOUTH BLVD ID1:NCI-027265
CHARLOTTE NC 28217 ID2:27265
MECKLENBURG STATUS:CLOSED OUT
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 97
REGIONAL UST DATA
UST NUMBER:MO-1401
INCIDENT NUMBER:27265
CD NUMBER:24
REEL NUMBER:0
REGIONAL CONTACT:MT
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
, ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:BOTH AT SAME SITE
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:4/20/1992
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:4/20/1992
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:24
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:74 DIST/DIR:0.48 SE ELEVATION:752 MAP ID:41
NAME:THE APPLE BUILDING REV:6/1/12
ADDRESS:3809 WEONA AVE ID1:NCI-010926
CHARLOTTE NC 28209 ID2:10926
MECKLENBURG STATUS:RESPONSE
CONTACT:RODGER JOHNSON PHONE:
SOURCE:NCDENR
Site Details Page - 98
REGIONAL UST DATA
UST NUMBER:MO-3891
INCIDENT NUMBER:10926
CD NUMBER:0
REEL NUMBER:0
REGIONAL CONTACT:BLM
REGIONAL OFFICE:MOR
DATE OCCURRED:6/28/1993
RESPONSIBLE COMPANY:
APPLE MANAGEMENT
290 CYPRESS GARDENS BLVD
WINTERHAVEN ,FL , 33880
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:NON COMMERCIAL
REGULATED:NON REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:U
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:
CLOSED REVIEW REQUESTED:
CASE CLOSED:
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:6/28/1993
CURRENT STATUS:CURRENT RECORD
RBCA GROUNDWATER:
POLLUTANT TYPE:HEATING OIL
CD NUMBER:0
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:66 DIST/DIR:0.50 NE ELEVATION:769 MAP ID:42
NAME:PEPSI BOTTLING COMPANY REV:6/1/12
ADDRESS:2820 SOUTH BLVD ID1:NCI-027982
CHARLOTTE NC 28224 ID2:27982
MECKLENBURG STATUS:CLOSED OUT
CONTACT: PHONE:
SOURCE:NCDENR
Site Details Page - 99
REGIONAL UST DATA
UST NUMBER:MO-7324
INCIDENT NUMBER:27982
CD NUMBER:288
REEL NUMBER:0
REGIONAL CONTACT:BLM
REGIONAL OFFICE:MOR
DATE OCCURRED:10/12/2005
RESPONSIBLE COMPANY:
PEPSI COLA BOTTLING COMPANY
,NC ,
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:INDUSTRIAL/COMMERCIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:6/29/2006
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:YES
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:7/6/2006
CLEAN UP:10/6/2005
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:288
RESPONSIBLE OWNER:-1
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:67 DIST/DIR:0.50 NE ELEVATION:769 MAP ID:42
NAME:PEPSI COLA BOTTLING COMPANY REV:6/1/12
ADDRESS:2820 SOUTH BLVD ID1:NCI-027939
CHARLOTTE NC 28209 ID2:27939
MECKLENBURG STATUS:
CONTACT:STUART MENZEL PHONE:7045236761
SOURCE:NCDENR
Site Details Page - 100
REGIONAL UST DATA
UST NUMBER:MO-7281
INCIDENT NUMBER:27939
CD NUMBER:323
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:9/6/2005
RESPONSIBLE COMPANY:
PEPSI COLA BOTTLING OF CHARLOT
2820 SOUTH BLVD/PO BOX 241167
CHARLOTTE ,NC , 28224
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:COMMERCIAL
REGULATED:REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:
RISK:U
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:IND
CORRECTIVE ACTION PLAN:
RBCA:RESIDENTIAL
CLOSED REVIEW REQUESTED:
CASE CLOSED:5/25/2007
CONTAMINATION:GROUNDWATER/BOTH
SUPPLY WELLS:0
MTBE IN WELL:0
MTBE IN GROUNDWATER:NO
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS
POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE
CD NUMBER:323
RESPONSIBLE OWNER:-1
RESPONSIBLE OPERATOR:-1
RESPONSIBLE LANDOWNER:-1
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
LUST
SEARCH ID:69 DIST/DIR:0.50 SE ELEVATION:716 MAP ID:43
NAME:ROBERT MAHONEY RESIDENCE REV:6/1/12
ADDRESS:3326 ANSON ST ID1:NCI-009125
CHARLOTTE NC 28209 ID2:9125
MECKLENBURG STATUS:CLOSED OUT
CONTACT:ROBERT MAHONEY PHONE:7045218257
SOURCE:NCDENR
Site Details Page - 101
REGIONAL UST DATA
UST NUMBER:MO-3621
INCIDENT NUMBER:9125
CD NUMBER:80
REEL NUMBER:0
REGIONAL CONTACT:AJS
REGIONAL OFFICE:MOR
DATE OCCURRED:
RESPONSIBLE COMPANY:
3326 ANSON STREET
CHARLOTTE ,NC , 28209
SOURCE:LEAK, UST
PETROLEUM TYPE:PETROLEUM
COMMERCIAL/NONCOMMERCIAL:NON COMMERCIAL
REGULATED:NON REGULATED
REGULATORY REQUIREMENT:
VIOLATION:
PHASE REQUIRED:
SITE PRIORITY:E?
RISK:L
RISK OF INCIDENT:L
INTERMEDIATE CONDITION:
LAND USE:
CORRECTIVE ACTION PLAN:
RBCA:SOIL TO GROUNDWATER
CLOSED REVIEW REQUESTED:
CASE CLOSED:5/25/1999
CONTAMINATION:SOIL
SUPPLY WELLS:0
MTBE IN WELL:
MTBE IN GROUNDWATER:UNKNOWN
LEAK DISCOVERED:0
LAND USE RESTRICTION FILED:
CLEAN UP:10/2/1992
CURRENT STATUS:ARCHIVED
RBCA GROUNDWATER:
POLLUTANT TYPE:HEATING OIL
CD NUMBER:80
RESPONSIBLE OWNER:0
RESPONSIBLE OPERATOR:0
RESPONSIBLE LANDOWNER:0
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:17 DIST/DIR:0.53 SE ELEVATION:765 MAP ID:44
NAME:MITCHELLS FORMAL WEAR (AFTER HOURS)REV:6/8/12
ADDRESS:115 SCALEYBARK RD ID1:NONCD0002084
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 102
SITE INFORMATION
EPA ID:NONCD0002084INCIDENT ID:18799
REP DISCOVERY DATE:25-JUN-98NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:
INCIDENT COMMENTS:PCE 17,000 PPB IN GW; PET. COMPOUNDS ALSO PRESENT IN GW MAY BE OFFSITE SOURCE; HISTORY OF PCE USE
ON SITE BY AT LEAST THREE DRY CLEANER OPERATORS;SENT TO DRY CLEANERS FUND 1/99. HAS UIC PERMIT (WI0300056) FOR
PERMANGANATE INJECTION (AKA AFTER HOURS FORMAL WEAR). 10/02: Certified into DSCA. 3/05: Prospective developer filed to enter
Brownfields Program. 1/07: new UIC application to inject BOS-100, a combination of activated carbon and iron. DWM Brownfields and DSCA are
both involved. Carolyn Minnich is project manager for Brownfields and it appears that Brownfields redevelopment associated with Scaleybark light
rail station is driving this project forward on a fast track.
DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE:
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:YES
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:18 DIST/DIR:0.62 NE ELEVATION:750 MAP ID:45
NAME:NCDOT ASPHALT SITE #57 - REA CONSTRUCTIO REV:6/8/12
ADDRESS:2701 YOUNGBLOOD CT ID1:NONCD0002172
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 103
SITE INFORMATION
EPA ID:NONCD0002172INCIDENT ID:87948
REP DISCOVERY DATE:17-OCT-06NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:
INCIDENT COMMENTS:ADDITIONAL AREA OF PRETOLEUM CONTAMINATED SOIL WAS DISCOVERED ON SITE. GW ALSO IMPACTED. LEAD
ALSO DETECTED IN SOIL ABOVE BACKGROUND.
EPA ID:NONCD0002172INCIDENT ID:17443
REP DISCOVERY DATE:05-JUN-97NOTICE DATE:
NEXT DUE DATE:31-JUL-06NEXT ACTION:Annual Monitoring Report
INCIDENT COMMENTS:PER NCDOT MOA CSA SUBMITTED EXTENT DEF. MINOR ADDTL WORK THEN CAP-ADDTL 2L MUST GO OUT FOR
PET. COMPOUNDS DETECTED DURING INVEST.POSSIBLY INVOVLEMENT WITH REA IN FUTURE;WSW SURVEY 6/18/98 NO 1500 FT WSWS.
2002-05: L-Cap approved, soil contam is below site specific cleanup levels; semi-annual monitoring with annual reports due at end of July;
concentrations are generally edging slightly downward. 2006-07 update: site is entering Brownfields agreement, MWs have been abandoned also
petroleum issues at this same location; reports submitted in 2006 have not been reviewed.
DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE:
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:24 DIST/DIR:0.62 NE ELEVATION:750 MAP ID:45
NAME:SUTTON PARK GROCERY REV:6/8/12
ADDRESS:2701 YOUNGBLOOD ST ID1:NONCD0002380
MONROE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 104
SITE INFORMATION
DATE ADDED: 5/20/2009RESIDENCE ON SITE: NO
DW WELL DISTANCE: > 1/4 MILESW INTAKE DISTANCE: NO INFO
PROCESS CODE: OTHER - OTHER VARIOUS PROCESSES SUCH AS OTHER MANUFACTURING, SANITATION SERVICE COMPANIES, AND FIRE
TRAINING GROUNDS; ALSO INCLUDES ALL SITES WHERE THE PROCESS CAUSING THE CONTAMINATION IS UNKNOWN
MEDIA CONTAMINATEDCONTAMINANT TYPE
GROUNDWATERORGANICS
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:12 DIST/DIR:0.62 SW ELEVATION:701 MAP ID:46
NAME:BALDOR ELECTRIC COMPANY REV:6/8/12
ADDRESS:3821 BARRINGER RD ID1:NONCD0001132
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 105
SITE INFORMATION
EPA ID:NONCD0001132INCIDENT ID:14993
REP DISCOVERY DATE:02-DEC-92NOTICE DATE:3/22/1994
NEXT DUE DATE:NEXT ACTION:REQUEST CSA
INCIDENT COMMENTS:TCE,PCE,1,1,1-TCA, NOV NEEDS TO BE SENT; BALDOR MOVED ITS OPERATION IN 1992; OTHER OPERATORS
BEFORE BALDOR INCLUDE POWERTRON (1974-1980)AND CONTRAVES GOERZ (1980-88); ALL THREE COMPANIES MANUFACTURED
ELECTRIC MOTORS. 2/03: BROWNFIELDS AGREEMENT IN PLACE.
DATE ADDED: 12/2/2005RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: OTHER - OTHER VARIOUS PROCESSES SUCH AS OTHER MANUFACTURING, SANITATION SERVICE COMPANIES, AND FIRE
TRAINING GROUNDS; ALSO INCLUDES ALL SITES WHERE THE PROCESS CAUSING THE CONTAMINATION IS UNKNOWN
MEDIA CONTAMINATEDCONTAMINANT TYPE
GROUNDWATERORGANICS
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:16 DIST/DIR:0.67 NE ELEVATION:704 MAP ID:47
NAME:MECKLENBURG CO. OIL SPILL BASIN CREE REV:6/8/12
ADDRESS:626 MILLER ST ID1:NCD986189983
CHARLOTTE NC ID2:
MECKLENBURG STATUS:NFA
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 106
SITE INFORMATION
DATE ADDED: 11/3/1992RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: PETROCHEMICALS - PETROCHEMICAL PRODUCTION, REFINING, TRANSPORT, STORAGE AND DISPOSAL
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: YES
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:22 DIST/DIR:0.75 NE ELEVATION:765 MAP ID:48
NAME:QUALEX REV:6/8/12
ADDRESS:2519 DISTRIBUTION ST ID1:NONCD0002348
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 107
SITE INFORMATION
EPA ID:NONCD0002348INCIDENT ID:87247
REP DISCOVERY DATE:07-FEB-05NOTICE DATE:2/18/2005
NEXT DUE DATE:23-MAY-05NEXT ACTION:CSA
INCIDENT COMMENTS:LARGE PHOTO PROCESSING FACILITY. SOIL CONTAMINATION INCLUDES SILVER,CYANIDE, SULFATE AND DRO &
MOTOR OIL TPH. ONLY GROUNDWATER CONTAMINATION ABOVE 2L IS SULFATE.
DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE:
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:10 DIST/DIR:0.81 NE ELEVATION:763 MAP ID:49
NAME:AIR LIQUIDE REV:6/8/12
ADDRESS:2414 SOUTH BLVD ID1:NONCD0001231
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 108
SITE INFORMATION
EPA ID:NONCD0001231INCIDENT ID:22103
REP DISCOVERY DATE:02-JUN-00NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:
INCIDENT COMMENTS:TCE, PCE, 1,1-DCE, C TET, 1,1,1,-TCA, CHLOROFORM FOUND IN GW DURING PHASE II ASSESSMENT FOR SALE OF
PROPERTY; SOURCE MAY BE OFFSITE.
DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE:
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:26 DIST/DIR:0.87 NE ELEVATION:770 MAP ID:50
NAME:TACO BELL #2 REV:6/8/12
ADDRESS:2405 SOUTH BLVD ID1:NONCD0002573
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 109
SITE INFORMATION
EPA ID:NONCD0002573INCIDENT ID:85197
REP DISCOVERY DATE:17-NOV-98NOTICE DATE:
NEXT DUE DATE:NEXT ACTION:
INCIDENT COMMENTS:8 PPB PCE DETECTED DURING LSA FOR UST RELEASE #14261.
DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE:
MEDIA CONTAMINATEDCONTAMINANT TYPE
SITE CATEGORIES
SPL SCORE: SPL: NO
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: YESNFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch
Site Detail Report
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
STATE
SEARCH ID:23 DIST/DIR:1.00 NE ELEVATION:777 MAP ID:51
NAME:SOUTHSIDE INVESTMENTS LLC REV:6/8/12
ADDRESS:2222 SOUTH BLVD ID1:NONCD0001076
CHARLOTTE NC ID2:
MECKLENBURG STATUS:ACTIVE
CONTACT: PHONE:
SOURCE:NC DENR
Site Details Page - 110
SITE INFORMATION
DATE ADDED: 6/1/2001RESIDENCE ON SITE: NO
DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO
PROCESS CODE: FURNITURE INDUSTRY - FURNITURE MANUFACTURING, FINISHING AND RESTORATION
MEDIA CONTAMINATEDCONTAMINANT TYPE
GROUNDWATERORGANICS
GROUNDWATERMETALS
SOILORGANICS
SOILMETALS
SITE CATEGORIES
SPL SCORE: 38.05SPL: YES
VOLUNTARY CLEANUP: NOREMEDIAL ACTION:
EVALUATIONS PENDING: NONFA: NO
NFA W/COVENANT: NODWQ: NO
SW SECTION: NONON NPL CERCLA: NO
NPL SITE: NONON TSD HAZ WASTE: NO
TSD: NORADIATION PROTECTION: NO
BROWNFIELD: DUPLICATE: NO
UST LEAD:NODSCA LEAD:NO
NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL:
NON HAZ SUB SITE NFA:NO
POLLUTANT ONLY SITE-OPEN:0
POLLUTANT ONLY SITE -NFA RESTRICTED:0
ORDERS, AGREEMENTS, AND SOLICITATIONS
Environmental FirstSearch Descriptions
NPL: EPA NATIONAL PRIORITY LIST - The National Priorities List is a list of the worst hazardous waste sites that have been
identified by Superfund. Sites are only put on the list after they have been scored using the Hazard Ranking System (HRS),
and have been subjected to public comment. Any site on the NPL is eligible for cleanup using Superfund Trust money. A
Superfund site is any land in the United States that has been contaminated by hazardous waste and identified by the
Environmental Protection Agency (EPA) as a candidate for cleanup because it poses a risk to human health and/or the
environment.FINAL - Currently on the Final NPLPROPOSED - Proposed for NPL
NPL DELISTED: EPA NATIONAL PRIORITY LIST Subset - Database of delisted NPL sites. The National Oil and Hazardous
Substances Pollution Contingency Plan (NCP) establishes the criteria that the EPA uses to delete sites from the NPL. In
accordance with 40 CFR 300.425.(e), sites may be deleted from the NPL where no further response is
appropriate.DELISTED - Deleted from the Final NPL
CERCLIS: EPA COMPREHENSIVE ENVIRONMENTAL RESPONSE COMPENSATION AND LIABILITY INFORMATION
SYSTEM (CERCLIS)- CERCLIS is a database of potential and confirmed hazardous waste sites at which the EPA Superfund
program has some involvement. It contains sites that are either proposed to be or are on the National Priorities List (NPL)
as well as sites that are in the screening and assessment phase for possible inclusion on the NPL.PART OF NPL- Site is part
of NPL siteDELETED - Deleted from the Final NPLFINAL - Currently on the Final NPLNOT PROPOSED - Not on the
NPLNOT VALID - Not Valid Site or IncidentPROPOSED - Proposed for NPLREMOVED - Removed from Proposed
NPLSCAN PLAN - Pre-proposal SiteWITHDRAWN - Withdrawn
NFRAP: EPA COMPREHENSIVE ENVIRONMENTAL RESPONSE COMPENSATION AND LIABILITY INFORMATION
SYSTEM ARCHIVED SITES - database of Archive designated CERCLA sites that, to the best of EPA's knowledge,
assessment has been completed and has determined no further steps will be taken to list this site on the National Priorities
List (NPL). This decision does not necessarily mean that there is no hazard associated with a given site; it only means that,
based upon available information, the location is not judged to be a potential NPL site.NFRAP – No Further Remedial
Action PlanP - Site is part of NPL siteD - Deleted from the Final NPLF - Currently on the Final NPLN - Not on the NPLO -
Not Valid Site or IncidentP - Proposed for NPLR - Removed from Proposed NPLS - Pre-proposal SiteW – Withdrawn
RCRA COR ACT: EPA RESOURCE CONSERVATION AND RECOVERY INFORMATION SYSTEM SITES - Database of
hazardous waste information contained in the Resource Conservation and Recovery Act Information (RCRAInfo), a national
program management and inventory system about hazardous waste handlers. In general, all generators, transporters,
treaters, storers, and disposers of hazardous waste are required to provide information about their activities to state
environmental agencies. These agencies, in turn pass on the information to regional and national EPA offices. This
regulation is governed by the Resource Conservation and Recovery Act (RCRA), as amended by the Hazardous and Solid
Waste Amendments of 1984.RCRAInfo facilities that have reported violations and subject to corrective actions.
RCRA TSD: EPA RESOURCE CONSERVATION AND RECOVERY INFORMATION SYSTEM TREATMENT, STORAGE, and
DISPOSAL FACILITIES. - Database of hazardous waste information contained in the Resource Conservation and Recovery
Act Information (RCRAInfo), a national program management and inventory system about hazardous waste handlers. In
general, all generators, transporters, treaters, storers, and disposers of hazardous waste are required to provide
information about their activities to state environmental agencies. These agencies, in turn pass on the information to
regional and national EPA offices. This regulation is governed by the Resource Conservation and Recovery Act (RCRA), as
amended by the Hazardous and Solid Waste Amendments of 1984.Facilities that treat, store, dispose, or incinerate
hazardous waste.
RCRA GEN: EPA/MA DEP/CT DEP RESOURCE CONSERVATION AND RECOVERY INFORMATION SYSTEM
GENERATORS - Database of hazardous waste information contained in the Resource Conservation and Recovery Act
Information (RCRAInfo), a national program management and inventory system about hazardous waste handlers. In
general, all generators, transporters, treaters, storers, and disposers of hazardous waste are required to provide
information about their activities to state environmental agencies. These agencies, in turn pass on the information to
regional and national EPA offices. This regulation is governed by the Resource Conservation and Recovery Act (RCRA), as
amended by the Hazardous and Solid Waste Amendments of 1984.Facilities that generate or transport hazardous waste or
meet other RCRA requirements.LGN - Large Quantity GeneratorsSGN - Small Quantity GeneratorsVGN – Conditionally
Exempt Generator.Included are RAATS (RCRA Administrative Action Tracking System) and CMEL (Compliance Monitoring
& Enforcement List) facilities. CONNECTICUT HAZARDOUS WASTE MANIFEST – Database of all shipments of hazardous
waste within, into or from Connecticut. The data includes date of shipment, transporter and TSD info, and material
shipped and quantity. This data is appended to the details of existing generator records. MASSACHUSETTES
HAZARDOUS WASTE GENERATOR – database of generators that are regulated under the MA DEP. VQN-MA =
generates less than 220 pounds or 27 gallons per month of hazardous waste or waste oil.SQN-MA = generates 220 to
2,200 pounds or 27 to 270 gallons per month of waste oil.LQG-MA = generates greater than 2,200 lbs of hazardous waste
or waste oil per month.
Fed Brownfield: EPA BROWNFIELD MANAGEMENT SYSTEM (BMS) - database designed to assist EPA in collecting,
tracking, and updating information, as well as reporting on the major activities and accomplishments of the various
Brownfield grant Programs./n CLEANUPS IN MY COMMUNITY (subset) - Sites, facilities and properties that have been
contaminated by hazardous materials and are being, or have been, cleaned up under EPA's brownfield’s program.
ERNS: EPA/NRC EMERGENCY RESPONSE NOTIFICATION SYSTEM (ERNS) - Database of incidents reported to the
National Response Center. These incidents include chemical spills, accidents involving chemicals (such as fires or
explosions), oil spills, transportation accidents that involve oil or chemicals, releases of radioactive materials, sightings of
oil sheens on bodies of water, terrorist incidents involving chemicals, incidents where illegally dumped chemicals have
been found, and drills intended to prepare responders to handle these kinds of incidents. Data since January 2001 has
been received from the National Response System database as the EPA no longer maintains this data.
Tribal Lands: DOI/BIA INDIAN LANDS OF THE UNITED STATES - Database of areas with boundaries established by
treaty, statute, and (or) executive or court order, recognized by the Federal Government as territory in which American
Indian tribes have primary governmental authority. The Indian Lands of the United States map layer shows areas of 640
acres or more, administered by the Bureau of Indian Affairs. Included are Federally-administered lands within a reservation
which may or may not be considered part of the reservation.BUREAU OF INDIAN AFFIARS CONTACT - Regional contact
information for the Bureau of Indian Affairs offices.
State/Tribal Sites: NCDENR STATE INACTIVE HAZARDOUS SITES LIST - database of sites and Facilities that are being
investigated due to reported releases of Hazardous substances. Included within this Inactive Hazardous Waste Sites
Inventory database are the following classifications: Inactive Hazardous Waste Sites (IHS), No Further Action Sites (NFA),
Duplicate Sites (DS), Inactive Hazardous Waste Sites Priority List Sites (SPL)
State Spills 90: NCDENR INCIDENT MANAGEMENT DATA (UST and Groundwater) - database of possible releases/spills
of contaminants. The data includes media effected, material released, source and site priority.
State/Tribal SWL: NCDENR ALL PERMITTED SOLID WASTE FACILITIES - database of C&D Landfill, Compost, House Hold
Hazardous Waste landfill, Incinerator (Industrial) Landfill, Incinerator (Medical) Landfill, Industrial Landfill, Land Clearing and
Inert Debris Landfill, Mixed Waste Processing Landfill, Municipal Solid Waste Landfill, Tire Treatment and Processing
Landfill, and Transfer and Processing Stations.
State/Tribal LUST: NCDENR INCIDENT MANAGEMENT DATA (UST and Groundwater) - database of leaking underground
storage tanks. This database is a subset of the Incident Management Data (UST and Groundwater) where the source is a
leaking ust. This data is concerned with petroleum storage systems and includes facilities and/or locations that have
reported the possible release of contaminants. This database also includes State Spill Sites. REGIONAL UST DATABASE
(SUBSET) - database of information obtained from the Regional Offices in which an incident has occurred. It provides a
more detailed explanation of current and historic activity for individual sites, as well as what was previously found in the
Incident Management Database.
State/Tribal UST/AST: NCDENR/EPA REGISTERED TANKS and FACILITY DATABASE - database of underground storage
tanks registered with the North Carolina Department of Environment and Natural Resources. Inclusion on this list indicates
the presence of underground petroleum storage tanks and therefore the potential for environmental problems. It does not
necessarily indicate existing problems.TRIBAL LAND UNDERGROUND STORAGE TANKS - database of underground
storage tanks that are reported to be on Native American lands.REGIONAL UST DATABASE - database of information
obtained from the Regional Offices. It provides a more detailed explanation of current and historic activity for individual
sites, as well as what was previously found in the Incident Management Database.
State/Tribal IC: NCDENR STATE INACTIVE HAZARDOUS SITES LIST SUBSET - database of sites and Facilities that have
land use restrictions and are being investigated due to reported releases of Hazardous substances. Included within this
Inactive Hazardous Waste Sites Inventory database are the following classifications: Inactive Hazardous Waste Sites (IHS),
No Further Action Sites (NFA), Duplicate Sites (DS), Inactive Hazardous Waste Sites Priority List Sites (SPL)
State/Tribal VCP: NCDENR STATE INACTIVE HAZARDOUS SITES LIST SUBSET- database of sites and Facilities that are
being investigated due to reported releases of Hazardous substances and have a voluntary cleanup aggreement. Included
within this Inactive Hazardous Waste Sites Inventory database are the following classifications: Inactive Hazardous Waste
Sites (IHS), No Further Action Sites (NFA), Duplicate Sites (DS), Inactive Hazardous Waste Sites Priority List Sites (SPL)
State/Tribal Brownfields: NCDENR BROWNFIELD PROJECTS INVENTORY - database of Active Eligible Sites, Projects
Pending Eligibility, and Finalized Brownfields Agreements.
State Other: NC DENR North Carolina Dry-Cleaning Solvent Cleanup Act Program (DSCA) – Database of certified site list
and project managers DENR DRYCLEANING SITES LIST – Database of all sites identified by the department with possible
dry-cleaning solvent contamination. List includes sites that have been certified into the DSCA Program.
Federal IC / EC: EPA FEDERAL ENGINEERING AND INSTITUTIONAL CONTROLS- Superfund sites that have either an
engineering or an institutional control. The data includes the control and the media contaminated. RESOURCE
CONSERVATION AND RECOVERY INFORMATION SYSTEM SITES (RCRA) – RCRA site the have institutional controls.
Dry Cleaners: NC DENR North Carolina Dry-Cleaning Solvent Cleanup Act Program (DSCA) – Database of certified site list
and project managers DENR DRYCLEANING SITES LIST – Database of all sites identified by the department with possible
dry-cleaning solvent contamination. List includes sites that have been certified into the DSCA Program.
Environmental FirstSearch Database Sources
NPL: EPA Environmental Protection Agency
Updated quarterly
NPL DELISTED: EPA Environmental Protection Agency
Updated quarterly
CERCLIS: EPA Environmental Protection Agency
Updated quarterly
NFRAP: EPA Environmental Protection Agency.
Updated quarterly
RCRA COR ACT: EPA Environmental Protection Agency.
Updated quarterly
RCRA TSD: EPA Environmental Protection Agency.
Updated quarterly
RCRA GEN: EPA/MA DEP/CT DEP Environmental Protection Agency, Massachusetts Department of Environmental
Protection, Connecticut Department of Environmental Protection
Updated quarterly
Fed Brownfield: EPA Environmental Protection Agency
Updated quarterly
ERNS: EPA/NRC Environmental Protection AgencyNational Response Center.
Updated annually
Tribal Lands: DOI/BIA United States Department of the InteriorBureau of Indian Affairs
Updated annually
State/Tribal Sites: NCDENR North Carolina Department of Environment and Natural Resources, Division of Waste
Management
Updated quarterly
State Spills 90: NCDENR North Carolina Department of Environment and Natural Resources, Division of Water
Quality/Groundwater Section
Updated quarterly
State/Tribal SWL: NCDENR North Carolina Department of Environment and Natural Resources, Division of Waste
Management
Updated annually
State/Tribal LUST: NCDENR North Carolina Department of Environment and Natural Resources, Division of Water
Quality/Groundwater Section
Updated quarterly
State/Tribal UST/AST: NCDENR/EPA North Carolina Department of Environment and Natural Resources, Division of Waste
ManagementEnvironmental Protection Agency
Updated quarterly
State/Tribal IC: NCDENR North Carolina Department of Environment and Natural Resources, Division of Waste
Management
Updated quarterly
State/Tribal VCP: NCDENR North Carolina Department of Environment and Natural Resources, Division of Waste
Management
Updated quarterly
State/Tribal Brownfields: NCDENR North Carolina Department of Environment and Natural Resources
Updated quarterly
State Other: NC DENR North Carolina Department of Environment and Natural Resources, Division of Waste Management
Updated quarterly
Federal IC / EC: EPA Environmental Protection Agency
Updated quarterly
Dry Cleaners: NC DENR North Carolina Department of Environment and Natural Resources, Division of Waste
Management
Updated quarterly
Environmental FirstSearch
Street Name Report for Streets within .25 Mile(s) of Target Property
Target Property:3405 S TRYON ST JOB:8606
CHARLOTTE, NC 28217
Street Name Dist/Dir Street Name Dist/Dir
Bank St 0.21 NE
Blairhill Rd 0.18 SW
Clanton Rd 0.09 NW
Hartford Ave 0.24 SE
Herman Ave 0.15 NE
May St 0.11 NE
Pelton St 0.13 SE
S TRYON ST 0.00--
Saint Vardell Ln 0.25 NW
State Hwy 49 0.02 NE
Trade Park Ct 0.03 NW
Tryclan Dr 0.13 SW
Wayne Ave 0.07 NE
Environmental FirstSearch
1 Mile Radius
ASTM Map: NPL, RCRACOR, STATE Sites
3405 S TRYON ST, CHARLOTTE, NC 28217
Source: Tele Atlas
Target Site (Latitude: 35.196858 Longitude: -80.875927) .......................
Identified Site, Multiple Sites, Receptor .....................................................
NPL, DELNPL, Brownfield, Solid Waste Landfill (SWL), Hazardous Waste
Triballand.....................................................................................................
Black Rings Represent 1/4 Mile Radius;Red Ring Represents 500 ft. Radius
Environmental FirstSearch
.5 Mile Radius
ASTM Map: CERCLIS, RCRATSD, LUST, SWL
3405 S TRYON ST, CHARLOTTE, NC 28217
Source: Tele Atlas
Target Site (Latitude: 35.196858 Longitude: -80.875927) .......................
Identified Site, Multiple Sites, Receptor .....................................................
NPL, DELNPL, Brownfield, Solid Waste Landfill (SWL), Hazardous Waste
Triballand.....................................................................................................
Black Rings Represent 1/4 Mile Radius;Red Ring Represents 500 ft. Radius
Environmental FirstSearch
.25 Mile Radius
ASTM Map: RCRAGEN, ERNS, UST, FED IC/EC, METH LABS
3405 S TRYON ST, CHARLOTTE, NC 28217
Source: Tele Atlas
Target Site (Latitude: 35.196858 Longitude: -80.875927) .......................
Identified Site, Multiple Sites, Receptor .....................................................
NPL, DELNPL, Brownfield, Solid Waste Landfill (SWL), Hazardous Waste
Triballand.....................................................................................................
Black Rings Represent 1/4 Mile Radius;Red Ring Represents 500 ft. Radius
Environmental FirstSearch
.5 Mile Radius
Non-ASTM Map: Spills 90, Spills 80, Brownfield
3405 S TRYON ST, CHARLOTTE, NC 28217
Source: Tele Atlas
Target Site (Latitude: 35.196858 Longitude: -80.875927) .......................
Identified Site, Multiple Sites, Receptor .....................................................
NPL, DELNPL, Brownfield, Solid Waste Landfill (SWL), Hazardous Waste
Triballand.....................................................................................................
National Historic Sites and Landmark Sites ................................................
Black Rings Represent 1/4 Mile Radius;Red Ring Represents 500 ft. Radius
SEP_14-2812 1A?L4 AN JUDY SULLIVAN
Soptember 10,2012
'784442e304 P-42
t(li.i Andrtly Drivt, Suitt A
Wcrr (:hcrter, lA 19380'4291
l€l 610.840,9100 frr 610,t|40.9199
wrvi\,.ildvirncadgeoservi(es.c0tn
2004-1292.15
Ada Shapiro, Trustoo
7804 C Fain iew RD #123
Charlofie, NC 28226
RE: Remedial Activides Satus
3405 South 'Iryon Sroot
CharlotlE, North Carolina
Dear Mrs. Shapiro:
Per your lequest, I have developed thc following infornation tLo summarize tle remediation aotivitiog ar
the 200 clanton Road property, which is adjacent to your properry at 340s south rryon stroot. sismensMedical Soltrtions, the former owner of20O clanton Road. hes been performing inveitigation activities in
nccordance with an Adminisrrativo Order ofConscnl with tho State of North Caroiina ind the Reqisterrd
Environmontal Consultant Progtam sinoe 1999. These activities are ongoing.
The remedial investigation identified -soil, sediment and groundwator impacted by the form€r plantop€mtions. ldentified substances of concem inoluded motals, chlorin;ted orginic solvents,'andpolyaromatic hydrocarbons. Thcso impact were both on and off the 200 clanton -noad proporty. Thosoil snd sedimcnt impscts lhat wor? on your propefty wer€ located in the e""ement "lon! y'our iastemproporty boufidary and in the dry creek bed along our southwestern property boundary. Th'e'remediationfor these soils aud sediments was completed in 2008, The soi) and sediments were excavated Ioresidential standsrds ald the material taken for disposal at a local landfill.
Groundwater beneath the 200 clanto' Road propeft)- and your propcny is impacted with chlorinatedorqdnic. solvents (primarily trichloroethen6) and assoaialod bicdegradation breakdorvn compounds(primarily 1,2-dichloroeth6oe and vinyl ohloride). The on-site sources of groundwater contaminationhave resulted in the migration of dissorvod concontrations onto your properfy. siemons has beenperforming activc temediation ofth€ source areas ou-site since 2005. TheRemeiial Action plan foi tho200 Clantofl Road property calls for grourrdwater source troatment on-site. This on_sitg troatment isanticipaEd to generate a natural rcmediarion ofthe lowor concontrations on your properlv. To date, thePhase I snd Ph8.eo [I groundwater. remediation.hare been relatively suooossfui in significantly reducingthe on-sitc oontaminant concentration$. A third phase ofon-site romediarion is planied fo, *,. rrrsi trarof 2013.
currently, the groundwater wclls on yo.ur property arong south rryon stroot and your westem prop€nyboundary hsve concotrtrations slightly above oi less thar-the srate's irinking water sundardr. etJng J;u,*^r:tm, prop:ry- l:undary, higher conc€ntrations are present. These higher concentrations are thJflcusot the ptann6d 2013 Foundwdter remedintion on the 200 Clanton Road piopeny.
ln addition' in october 2012, five (5) deep soil gas sampres wero oolrected on your prop€rty per new stato
Fui91nc6 tg evaluete the potential for uapors irom thi groundwater to mrgrate upwards and into vourbuilding. Two of the locations were next to your buildirig on the oastem "ia .*i'rr". riarr. ii. ir.,""(3) samples collectod rvore located in the eastem portion of your propeny where the higher groundwater
f \t djdrp(rod\2ooa,2y2.P.t6n Cr$c tch{dtd Aertdn\S* fiLdcoeunnrisr\A.nldriidn Aahhlar Sutrrsrr {oci
sEP- 14-2A 12 1E:15 Ail JUITY SULL I VAN '7944424=84 P. S3
Ada Shapiro, Trustet
2004-lan-rs
Septemb$ I0, 20|2
Page 2 of2
ooncentrations ara looated. Two additional locations wore sttompt€d but thc samplas could not be
collmted since tbe soils were very tight. All five (5) soil gas ramples w€re b€low thc stato's
industriaUcommgrcial vapor inEusion screening lovels. Thereforc, no ftrrthor agtions were wafrantod or
r6quirod,
I hope this suftmary infomdtion sufficiently explaine thc historic snd ongoing remedial aotivitiog at the
200 Clanton Road property and related activitics on your propeny. In thc future we will need continu€d
access to the moniloringwells on your proporly, Plcase do not h€Bitato !o contact mc with any questions.
Sinoorely,
ADVANCED CEOSERVICES
SWK:vm
sc: Robert Friodman, Siomens
Stephefi W. KirsohniflP.E.
F:\tldacdae4rmal292.f.l6i Cto. &$.dn ld.lvt .'l'd\Co'8hi!.rho4trE dirriq A.r,vita* Sur.uy.ds
APPENDIX IV
HISTORICAL RESEARCH DOCUMENTATION
APPENDIX V
SITE PHOTOGRAPHS
PHOTOGRAPHS
Photograph No. 1
View of the subject site.
Photograph No. 2
View of the subject site.
PHOTOGRAPHS
Photograph No. 3
View of the showroom and offices.
Photograph No. 4
View of the production area.
PHOTOGRAPHS
Photograph No. 5
View of the production area.
Photograph No. 6
View of various paint containers.
PHOTOGRAPHS
Photograph No. 7
View of the ink storage room.
Photograph No. 8
View of the wash basin and floor drain.
PHOTOGRAPHS
Photograph No. 9
View of one air compressor.
Photograph No. 10
View of the second air compressor.
PHOTOGRAPHS
Photograph No. 11
Typical view of the monitoring wells on-site.
Photograph No. 12
View of the creek on the southern property boundary.
PHOTOGRAPHS
Photograph No. 13
View of the natural gas connection.
Photograph No. 14
View of the pad mounted transformer.
APPENDIX VI
STATEMENT OF QUALIFICATIONS
plf David E. Valentine
Staff Environmental Technician
EDUCATION
Bachelor of Science, 2011, Natural Resources
The University of the South Sewanee, Tennessee
Mr. Valentine is a Staff Environmental Technician for
ECS, Carolinas, LLP. Mr. Valentine is primarily
responsible for conducting environmental site
assessments.
ENVIRONMENTAL ASSESSMENT -Mr. Valentine has
performed numerous Phase I Environmental Site
Assessments (ESAs)to determine environmental
liabilities for commercial, residential, institutional,
industrial and retail facilities. He has performed
environmental assessments in North Carolina and
South Carolina. He has experience performing
preliminary ESAs to evaluate on-site and off-site
concerns that may impact the site. His scope of work
typically includes performance of an on-site and off-
site reconnaissance, reviewing regulatory lists,
obtaining and reviewing aerial photographs,
topographic maps, Sanborn Fire Insurance Maps, city
directories, and other published information.
PHASE II ENVIRONMENTAL SITE ASSESSMENT -Mr.
Valentine has assisted with field activities for Phase II
Environmental Site Assessments (ESAs)including
both soil and groundwater investigations. Types of
assessments include leaking underground storage
tanks (USTs), oil and hazardous material spills or
releases. On-site activities include locating and
drilling soil borings, collecting and screening soil
samples, installing monitoring wells and collecting
groundwater samples.
UNDERGROUND STORAGE TANKS -Mr. Valentine has
assisted with several UST assessments and removals
including collecting samples and monitoring field
activities. He has performed several risk-based
assessments including Limited Site Assessments
(LSAs). He has monitored field activities and collected
samples during removal of petroleum contaminated
soils.
SAMPLE PROJECT EXPERIENCE
·Skybrook Village, Huntersville, NC
·RW Garcia Building, Lincolnton, NC
·Charlotte Medical Office Building, Charlotte, NC
·Hartsville Apartments, Hartsville, SC
·Charter School, Mooresville, NC
·Westgate Industrial Site, Clover, SC
·Southcross Industrial Center, Rock Hill, SC
·International Corporate Center, Concord, NC
·Circle at Southend, Charlotte, NC
·Crossland Dental, Mount Pleasant, SC
plf Brian E. Maas REM
Director of Environmental Services
EDUCATION
Bachelor of Science, Resource Management, 1986,
College of Environmental Science and Forestry,
Syracuse University, Syracuse, NY
Associates of Applied Science, 1984, SUNY Ranger
School, Wanakena, NY
REGISTRATIONS/CERTIFICATIONS
Registered Environmental Manager (REM); Asbestos
Inspector: NC, SC, TN, & VA; Asbestos
Management Planner: NC, SC, TN, & VA; Asbestos
Abatement Designer: NC, TN, & VA; Inspector/Risk
Assessor: NC; Certified Mold Remediator – Indoor
Air Quality Association; OSHA 40 Hour and 8 Hour
Training
Mr. Maas is the Director of Environmental Services
for ECS Carolinas, LLP and assists with business
development, marketing, technical oversight and
coordination of environmental services for 13
branches of ECS throughout North Carolina and
South Carolina. Mr. Maas has been performing
environmental consulting work for 20 years and has
worked with ECS for 15 years. His specialties include
transactional environmental services (Phase I ESAs,
Phase II and Phase III ESAs), Brownfields
assessments, remediation and redevelopment, mold,
asbestos, lead‐based paint, indoor air quality and
wetland services.
NATURAL RESOURCES SERVICES ‐ Mr. Maas has
experience in consulting with clients and performing
wetland identification, delineation, U.S. Army Corp.
of Engineers verification. He has experience in
delineating different varieties of wetland ecosystems
and has experience with Federal and State permitting
requirements and regulations. Additionally, Mr. Maas
has experience in performing endangered species
assessments, natural resource investigations, and
stream and riparian area restoration and mitigation.
PHASE 1, FCC/NEPA AND PHASE II ENVIRONMENTAL
ASSESSMENTS ‐ Mr. Maas has performed over 1,000
Phase I, FCC/NEPA, and Phase II environmental
assessments to determine environmental liabilities
for Real Property Transfers. He has performed
environmental liability assessments in North
Carolina, South Carolina, Virginia, West Virginia,
Alabama, Tennessee, Utah, Ohio and New York.
ENVIRONMENTAL SITE ASSESSMENTS ‐ Mr. Maas has
managed numerous phase II environmental site
assessments including both soil and groundwater
investigations. Types of assessments include leaking
underground storage tanks (USTs), oil and hazardous
material spills, and wastewater discharges. On‐site
activities include locating and drilling soil borings,
collecting and screening soil samples, installing
monitoring wells and collecting groundwater
samples. Mr. Maas uses the data collected from soil
and groundwater sample analyses to determine the
area impacted and to recommend further
assessment or remediation activities, if necessary.
Place picture