Loading...
HomeMy WebLinkAbout25050_Assistance League_Phase I ESA_20121101PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORT FORMER CAROLINA MARKING DEVICES, INC. 3405 SOUTH TRYON STREET CHARLOTTE, MECKLENBURG COUNTY, NORTH CAROLINA 28217 ECS PROJECT NO. 08-8606 FOR THE ASSISTANCE LEAGUE OF CHARLOTTE NOVEMBER 01, 2012 November 01, 2012 Mr. Randy Russell The Assistance League of Charlotte PO Box 471112 Charlotte, North Carolina 28247 ECS Project No. 08-8606 Reference:Phase I Environmental Site Assessment Report, Former Carolina Marking Devices, Inc., 3405 South Tryon Street, Charlotte, Mecklenburg County, North Carolina 28217 Dear Mr. Russell: ECS Carolinas, LLP (ECS) is pleased to provide The Assistance League of Charlotte with the results of our Phase I Environmental Site Assessment (ESA) for the referenced property. ECS services were provided in general accordance with ECS Proposal No. 08- 14220P dated September 18, 2012 and generally meet the requirements of ASTM E 1527-05, Standard Practice for Environmental Site Assessments: Phase I Environmental Site Assessment Process and EPA Standards and Practices for All Appropriate Inquiry contained in 40 CFR Part 312. If there are questions regarding this report, or a need for further information, please contact the undersigned at (704) 525-5152. ECS CAROLINAS, LLP David E. Valentine Environmental Technician Brian E. Maas, REM Director of Environmental Services ECS Project No. 08-8606 November 01, 2012 ENVIRONMENTAL PROFESSIONAL STATEMENT We declare that, to the best of our professional knowledge and belief,we meet the definition of Environmental Professional as defined in § 312.10 of 40 CFR 312. We have the specific qualifications based on education, training, and experience to assess a property of the nature, history, and setting of the subject property.We have developed and performed all appropriate inquiries in conformance with the standards and practices set forth in 40 CFR Part 312. Brian E. Maas, REM November 01, 2012 Director of Environmental Services Phase I Environmental Site Assessment Report Former Carolina Marking Devices, Inc. 3405 South Tryon Street Charlotte, Mecklenburg County, North Carolina 28217 CLIENT The Assistance League of Charlotte PO Box 471112 Charlotte, North Carolina 28247 SUBMITTED BY ECS Carolinas, LLP 1812 Center Park Drive Suite D Charlotte, North Carolina 28217 PROJECT 08-8606 DATE November 01, 2012 PHASE I ENVIRONMENTAL SITE ASSESSMENT REPORT FORMER CAROLINA MARKING DEVICES, INC. 3405 SOUTH TRYON STREET CHARLOTTE, NORTH CAROLINA 28217 ECS PROJECT NO. 08-8606 SECTION PAGE 1.0 EXECUTIVE SUMMARY ................................................................................1 2.0 INTRODUCTION.............................................................................................3 2.1 Purpose and Reason for Performing Phase I ESA.................................3 2.2 Scope of Services...................................................................................3 2.3 Limitations ..............................................................................................3 3.0 SITE DESCRIPTION.......................................................................................5 3.1 Site Location and Legal Description.......................................................5 3.2 Physical Setting and Hydrogeology........................................................5 3.3 Current Use and Description of the Site.................................................6 3.4 Current Uses of the Adjoining Properties ...............................................6 4.0 USER PROVIDED INFORMATION ................................................................7 4.1 Title Information......................................................................................7 4.2 Environmental Liens or Activity and Use Limitations..............................7 4.3 Specialized Knowledge ..........................................................................7 4.4 Commonly Known or Reasonably Ascertainable Information ................7 4.5 Valuation Reduction for Environmental Issues.......................................7 4.6 Owner, Property Manager, and Occupant Information...........................7 4.7 Degree of Obviousness ..........................................................................7 5.0 RECORDS REVIEW .......................................................................................8 5.1 Federal Databases .................................................................................9 5.2 State Databases...................................................................................11 5.3 Historical Use Information ....................................................................15 6.0 SITE AND AREA RECONNAISSANCE .......................................................19 6.1 Methodology and Limiting Conditions...................................................19 6.2 On-Site Features ..................................................................................19 6.3 Adjoining and Nearby Properties..........................................................21 7.0 ADDITIONAL SERVICES.............................................................................22 7.1 Non-Scope Issues ................................................................................22 7.2 Previous Reports Review .....................................................................22 8.0 INTERVIEWS................................................................................................23 9.0 FINDINGS .....................................................................................................24 10.0 CONCLUSIONS AND OPINIONS ................................................................26 11.0 REFERENCES..............................................................................................27 Table of Contents Page 2 APPENDICES I Figures II Correspondence and User Questionnaire III Regulatory Records Documentation IV Historical Research Documentation V Site Photographs VI Statement of Qualifications ECS Project No. 08-8606 November 01, 2012 -1 - 1.0 EXECUTIVE SUMMARY ECS Carolinas, LLP was contracted by The Assistance League of Charlotte to perform an ASTM Standard E-1527-05, Phase I Environmental Site Assessment (ESA) for a site located at 3405 South Tryon Street in Charlotte, Mecklenburg County, North Carolina. According to the Mecklenburg County tax information system, the site is identified as Parcel ID No. 14702131.Any exceptions to or deletions from this practice are described in Section 2.3 of this report. The site is an approximate 3.03 acre tract located at 3405 South Tryon Street in Charlotte, Mecklenburg County, North Carolina.The site is developed with an approximate 24,000 square foot, one-story commercial warehouse.The building was constructed in 1991 and was formerly occupied by Carolina Marking Devices, Inc.The site was used for production of marking devices (stamps, badges, notary seals, etc.) that utilized various inks.The building contains a showroom, offices, a production area and a warehouse.The remainder of the site consists of an asphalt paved parking lot and landscaped areas.The site is provided water and sanitary sewer services through the Charlotte Mecklenburg Utilities Department.The site is provided natural gas through Piedmont Natural Gas.ECS did not observe underground storage tanks (USTs) associated with the site. ECS observed two air compressors in the building that were leaking oil.The oil appeared to have traveled into cracks in the concrete flooring.ECS considers the oil from the air compressors to be a recognized environmental condition (REC) of the site. ECS observed five groundwater monitoring wells located on the site.The monitoring wells are associated with on-going remediation activities from the former Pelton & Crane facility as discussed in Section 5.2.ECS considers these monitoring wells to be RECs of the site. ECS reviewed historical aerial photographs and city directories for the subject site and surrounding areas.The aerial photograph review depicted the site to be historically undeveloped until the current facility was constructed in 1991.Surrounding properties were historically developed with residential and commercial structures.The site is listed as Carolina Marking Devices, Inc. and Caromark Stamps and Signs in the 2005 city directory. In the 2000, 1995 and 1992 city directories, the site is listed as Carolina Marking Devices, Inc. The site is not listed prior to the 1992 city directories.The site is currently bounded on the north by CATS bus facility; on the east by goodmortgage.com and Lifespan; on the south by USTT, Hertron, Staffzone and C.A.R.S.; and, on the west by South Tryon Street, 77 Corporate Park and Fast Signs. The site is located in a commercial/residential area of Charlotte, North Carolina. A regulatory records search report, dated October 8, 2012 of ASTM standard and supplemental databases was prepared for the site by FirstSearch. FirstSearch identified multiple properties within the search distance of inquiry and one to be of environmental concern with respect to the site: ECS Project No. 08-8606 November 01, 2012 -2 - ·Pelton & Crane Plant (Former), 200 Clanton Road -located on the adjoining property to the east and topographically upgradient of the site.According to the FirstSearch report, this facility formerly operated one 2,000-gallon oil UST and one 650-gallon oil UST.ECS reviewed regulatory files regarding this facility. During the removal of the USTs soil and groundwater contamination were identified.The contaminants identified included metals, chlorinated organic solvents and polyaromatic hydrocarbons.Contamination was discovered on the subject site (3405 South Tryon Street) along the eastern site boundary and in the creek bed.Soil remediation was completed in 2008. Groundwater source treatment has been conducted since 2005.Monitoring wells located on the subject site indicate elevated groundwater contaminants.The monitoring wells indicated that the groundwater flows radially from the facility towards the southwest, west and northwest.Additional remediation activities are planned for 2013.In October 2012,deep soil gas samples were collected on the subject site to evaluate the potential for vapor intrusion. The samples collected were below the state's industrial/commercial vapor intrusion levels.Based on contamination being identified on-site, ECS considers the release associated with this off-site facility to be an REC of the site. As documented and qualified by this report, this assessment has revealed the following evidence of RECs in connection with the property: On-Site: Potential exists that the discharge oil from the air compressors could impact soil and/or groundwater beneath the site.ECS recommends additional assessment to determine if soil and/or groundwater beneath the site has been impacted. ECS observed five groundwater monitoring wells on-site that are associated with on- going remediation activities at the former Pelton & Crane facility located on the adjoining property to the east. Off-Site: The former Pelton & Crane facility located on the adjoining property to the east is currently undergoing remediation activities.ECS recommends that the responsible party continue with remediation activities for the former Pelton & Crane facility.ECS also recommends requesting and periodically reviewing sampling and reporting conducted by the responsible party and having a qualified environmental professional review the findings. This Executive Summary is an integral part of the Phase I Environmental Site Assessment report. ECS recommends that the report be read in its entirety. ECS Project No. 08-8606 November 01, 2012 -3 - 2.0 INTRODUCTION 2.1 Purpose and Reason for Performing Phase I ESA The purpose of the ESA was to: ·evaluate the probability of impact to the surface water, groundwater and/or soils within the property boundaries through a review of regulatory information and a reconnaissance of the subject site and vicinity; ·evaluate historical land usage to identify previous conditions that could potentially impact the environmental condition of the site; ·evaluate the potential for on-site and off-site contamination; ·provide a professional opinion regarding the potential for environmental impact at the site, and a list of Recognized Environmental Conditions; and, ·conduct all appropriate inquiry as defined by ASTM-E 1527-05 The reason for the ESA is to qualify for landowner liability protections to CERCLA liability. 2.2 Scope of Services The environmental assessment was conducted in accordance with ASTM E 1527-05 and EPA Standards and Practices for All Appropriate Inquiry (40 CFR §312.10). The environmental assessment was conducted under the supervision or responsible charge of an individual that qualifies as an environmental professional, as defined in 40 CFR §312.10. ECS Carolinas, LLP was contracted by The Assistance League of Charlotte to perform a Phase I ESA for property located at 3405 South Tryon Street, Charlotte, Mecklenburg County, North Carolina. The site is identified as Mecklenburg County Parcel ID No. 14702131. 2.3 Limitations The ESA involved a reconnaissance of the site and contiguous properties and a review of regulatory and historical information in accordance with the ASTM standard and EPA regulation referenced herein. No non-scope considerations or additional issues such as asbestos, radon, wetlands or mold were investigated, unless otherwise described in Section 7.0 of this report. ECS Project No. 08-8606 November 01, 2012 -4 - The conclusions and/or recommendations presented within this report are based upon a level of investigation consistent with the standard of care and skill exercised by members of the same profession currently practicing in the same locality under similar conditions. The intent of this assessment is to identify the potential for recognized environmental conditions in connection with the site; however, no environmental site assessment can completely eliminate uncertainty regarding the potential for recognized environmental conditions in connection with the site. The findings of this ESA are not intended to serve as an audit for health and safety compliance issues pertaining to improvements or activities at the site. ECS is not liable for the discovery or elimination of hazards that may potentially cause damage, accidents or injury. Observations, conclusions and/or recommendations pertaining to environmental conditions at the subject site are necessarily limited to conditions observed, and or materials reviewed at the time this study was undertaken. It was not the purpose of this study to determine the actual presence, degree or extent of contamination, if any, at this site. This could require additional exploratory work, including sampling and laboratory analysis. No warranty, expressed or implied, is made with regard to the conclusions and/or recommendations presented within this report. ASTM E-1527-05 defines a "recognized environmental condition" as "the presence or likely presence of any hazardous substances or petroleum products on a property under conditions that indicate an existing release, a past release, or a material threat of a release of any hazardous substances or petroleum products into structures on the property or into the ground, groundwater, or surface water of the property. The term includes hazardous substances or petroleum products even under conditions in compliance with laws. The term is not intended to include de minimis conditions that generally do not present a threat to human health or the environment and that generally would not be the subject of an enforcement action if brought to the attention of appropriate governmental agencies." ASTM E-1527-05 defines a “business environmental risk” as “a risk which can have a material environmental or environmentally-driven impact on the business associated with the current or planned use of a parcel of commercial real estate”. Client-imposed limitations and site condition limitations, if encountered, are detailed in Section 6.1 Methodology and Limiting Conditions. This report is provided for the exclusive use of The Assistance League of Charlotte. This report is not intended to be used or relied upon in connection with other projects or by other unidentified third parties. The use of this report by undesignated third party or parties will be at such party’s sole risk and ECS disclaims liability for such third party use or reliance. ECS Project No. 08-8606 November 01, 2012 -5 - 3.0 SITE DESCRIPTION 3.1 Site Location and Legal Description The site referred to as “subject site”or “site” is located at 3405 South Tryon Street Charlotte, Mecklenburg County, North Carolina (Figure 1, Appendix I). A legal description of the property was not provided to ECS. 3.2 Physical Setting and Hydrogeology As determined from the USGS Topographic Map, Charlotte West & Charlotte East, North Carolina Quadrangles (Figure 1), the site’s elevation is approximately 720 feet above mean sea level.Surface runoff on the site generally flows to the west-northwest toward an unnamed tributary of Irwin Creek.Limited areas to the northeast-east appear to be upgradient of the site based on the groundwater flow direction inferred from the surface topography. According to the Geologic Map of North Carolina (1985), the subject property is situated in the Charlotte Belt of the Piedmont Physiographic Province with the underlying bedrock composed of metamorphosed mafic rock. The Piedmont Physiographic Province is characterized by gently rolling topography, deeply weathered bedrock, and a relative paucity of solid outcrop. Rocks are strongly weathered in the Piedmont's humid climate and bedrock is generally buried under a thick (2-20 m) blanket of saprolite. Outcrops are commonly restricted to stream valleys where saprolite has been removed by erosion. The topography becomes somewhat more rugged with proximity to the Blue Ridge, where local monadnocks of more resistant rock occur. The soils encountered in this area are the residual product of in-place chemical weathering of rock presently underlying the site. In general, shallow unconfined groundwater movement within the overlying soils is controlled largely by topographic gradients. However, as the groundwater percolates downward to the bedrock, it becomes controlled by the orientation of the rock fracture systems. Thus, the direction of groundwater movement may not be consistent with the reflecting topography. Recharge occurs primarily by infiltration along higher elevations and typically discharges into streams or other surface water bodies. The elevation of the shallow water table is transient and can vary with seasonal fluctuations in precipitation. Movement of groundwater under water table conditions is generally from higher to lower elevations. As such, shallow groundwater would be expected to flow to the west-northwest beneath the site. Actual site groundwater flow direction cannot be determined without site-specific groundwater information determined through the installation of groundwater monitoring wells. ECS Project No. 08-8606 November 01, 2012 -6 - 3.3 Current Use and Description of the Site The site is an approximate 3.03 acre tract located at 3405 South Tryon Street in Charlotte, Mecklenburg County, North Carolina.The site is developed with an approximate 24,000 square foot, one-story commercial warehouse.The building was constructed in 1991 and was formerly occupied by Carolina Marking Devices, Inc.The building contains a showroom, offices, a production area and a warehouse.The remainder of the site consists of an asphalt paved parking lot and landscaped areas. 3.4 Current Uses of the Adjoining Properties The site is bounded on the north by CATS bus facility; on the east by goodmortgage.com and Lifespan; on the south by USTT, Hertron, Staffzone and C.A.R.S.; and, on the west by South Tryon Street, 77 Corporate Park and Fast Signs. Additional information regarding the adjoining and nearby properties is located in Section 6.3. ECS Project No. 08-8606 November 01, 2012 -7 - 4.0 USER PROVIDED INFORMATION ECS was not provided with a User Questionnaire for our review. ECS considers this a data failure (historical data gap). If this information is provided at a later date, ECS will review it for evidence of environmental concerns and issue an addendum to this report it the review indicated a material difference in our findings. However, based on other historical information presented, ECS considers this data failure to be non-significant. This data failure has not affected ECS’s ability to identify Recognized Environmental Conditions (RECs) relative to the site. 4.1 Title Information ECS was not provided with a chain-of-title for our review. 4.2 Environmental Liens or Activity and Use Limitations At the time of this report, ECS was not provided with the environmental lien or activity and land use limitations for the subject site. 4.3 Specialized Knowledge At the time of this report, ECS was not provided with specialized knowledge for the subject site. 4.4 Commonly Known or Reasonably Ascertainable Information At the time of this report, ECS was not provided with commonly known or reasonably ascertainable information for the subject site. 4.5 Valuation Reduction for Environmental Issues At the time of this report, ECS was not provided with information regarding valuation reduction for environmental issues for the subject site. 4.6 Owner, Property Manager, and Occupant Information According to the Mecklenburg County tax information, the owner of the site is Soloman Shapiro. 4.7 Degree of Obviousness At the time of this report, ECS was not provided with degree of obviousness information for the subject site. ECS Project No. 08-8606 November 01, 2012 -8 - 5.0 RECORDS REVIEW A regulatory records search of ASTM standard and supplemental databases was conducted for the site and is included in Appendix III. The regulatory search report in the appendix includes additional details about the regulatory databases that were reviewed. The regulatory records search involves searching a series of databases for facilities that are located within a specified distance from the subject property. The ASTM standard specifies an approximate minimum search distance from the subject site for each database. Pursuant to ASTM, the approximate minimum search distance may be reduced for each standard environmental record except for Federal NPL site list, and Federal RCRA TSD list. According to ASTM, government information obtained from nongovernmental sources may be considered current if the source updates the information at least every 90 days or, for information that is updated less frequently than quarterly by the government agency, within 90 days of date the government agency makes the information available to the public. The following table indicates the standard environmental record sources and the approximate minimum search distances for each. Standard Environmental Record Sources Approximate Minimum Search Distance Per ASTM (miles) Federal NPL 1.0 Federal Delisted NPL 0.5 Federal CERCLIS 0.5 Federal CERCLIS NFRAP 0.5 Federal RCRA CORRACTS 1.0 Federal RCRA non-CORRACTS TSD 0.5 Federal RCRA Generators Subject Site and Adjoining Properties Federal IC/EC Subject Site Only Federal ERNS Subject Site Only State and Tribal Hazardous Waste Sites (NPL Equivalent)1.0 State and Tribal Hazardous Waste Sites (CERCLIS Equivalent)0.5 State and Tribal Landfill and/or solid waste disposal sites 0.5 State and Tribal LUST 0.5 State and Tribal Registered UST Subject Site and Adjoining Properties State and Tribal IC/EC Subject Site Only State and Tribal Voluntary Cleanup (VCP) Sites 0.5 State and Tribal Brownfield Sites 0.5 ECS Project No. 08-8606 November 01, 2012 -9 - Based on our knowledge of the subject property and the surrounding area, ECS attempts to verify and interpret this data. While this attempt at verification is made with due diligence, ECS cannot guarantee the accuracy of the record(s) search beyond that of information provided by the regulatory report(s). Mapped and unmapped sites identified in the regulatory report(s) that are not addressed below were field verified and are not believed to be within the approximate minimum search distance and are excluded from this ESA report. ECS makes no warranty regarding the accuracy of the database report information included within the regulatory report(s). ECS maintained the ASTM recommended search distances during this assessment. 5.1 Federal Databases Federal National Priorities List (NPL) The NPL is a subset of Comprehensive Environmental Response, Compensation, and Liability Information System (CERCLIS) and identifies “superfund” sites that have had documented contamination incidents. The site was not identified on the NPL. No off-site properties within the minimum search distance of inquiry were reported as being on the NPL. Federal Delisted NPL The Delisted NPL identifies sites previously listed on the NPL where no further response is appropriate. The site was not identified on the Delisted NPL. No off-site properties within the minimum search distance of inquiry were reported as being on the Delisted NPL. Federal CERCLIS CERCLIS contains data on potential hazardous waste sites that have been reported to the United States Environmental Protection Agency (USEPA). CERCLIS contains sites that are either proposed to or on the NPL and sites which are in the screening and assessment phase for possible inclusion on the NPL. The site was not identified on the CERCLIS database. No off-site properties within the minimum search distance of inquiry were reported as being on the CERCLIS database. Federal CERCLIS No Further Remedial Action Planned (NFRAP) CERCLIS sites designated as NFRAP have been removed from CERCLIS. NFRAP sites may be sites where, following an initial investigation, no contamination was found, contamination was removed quickly without the need for the site to be placed on the NPL, or the contamination was not serious enough to require federal Superfund action or NPL consideration. ECS Project No. 08-8606 November 01, 2012 -10 - The site was not identified on the CERCLIS NFRAP. One or more off-site properties within the minimum search distance of inquiry were reported as being on the CERCLIS NFRAP database. The FirstSearch report identified three properties within the search distance of inquiry. Based on the distance from the site and/or the presumed groundwater flow direction inferred from surface topography, ECS does not consider these facilities to be RECs of the site. Federal Corrective Action Report (CORRACTS) CORRACTS identifies hazardous waste handlers that have been subject to corrective action under Resource Conservation and Recovery Act (RCRA). The site was not identified by CORRACTS. No off-site properties within the minimum search distance of inquiry were reported as being on CORRACTS. Federal Resource Conservation and Recovery Information System (RCRIS)– Treatment, Storage and Disposal (TSD)Facilities RCRIS identifies facilities that treat, store or dispose of hazardous wastes as defined by the RCRA. TSDs treat, store or dispose of hazardous waste. The site was not identified as a hazardous waste TSD facility. No off-site properties within the minimum search distance of inquiry were reported as being a hazardous waste TSD facility. Federal RCRIS -Generators RCRIS identifies facilities that generate hazardous wastes as defined by the RCRA. Conditionally exempt small quantity generators generate less than 100 kilograms of hazardous waste, or less than 1 kilogram of acutely hazardous waste, per month. Small quantity generators (SQGs) generate between 100 and 1,000 kilograms of hazardous waste per month. Large quantity generators (LQGs) generate more than 1,000 kilograms of hazardous waste or more than 1 kilogram of acutely hazardous waste per month. The site was not identified as a hazardous waste generator. No off-site properties within the minimum search distance of inquiry were reported as being a hazardous waste generator. Federal Engineering Controls (EC) List The Federal EC list identifies engineering controls including various forms of caps, building foundations, liners, and treatment methods used to eliminate pathways for regulated substances to enter environmental media or affect human health. The site was not identified on the EC list. ECS Project No. 08-8606 November 01, 2012 -11 - Federal Institutional Controls (IC) List The Federal IC list identifies institutional controls including administrative measures, such as groundwater use restrictions, construction restrictions, property use restrictions, and post remediation care requirements intended to prevent exposure to contaminants. The site was not identified on the IC list. Federal Emergency Response Notification System (ERNS) The ERNS list is a national database that stores and records information on reported releases of hazardous substances, including petroleum products. The site was not identified on the ERNS list. 5.2 State Databases Incident Management Database (IMD) The IMD, maintained by NCDENR-DWM, is a record of groundwater and soil contamination incidents. The site was not identified on the IMD. One or more off-site properties within the minimum search distance of inquiry were reported as being on the IMD. ·Pelton & Crane Plant (Former), 200 Clanton Road -located on the adjoining property to the east and topographically upgradient of the site.According to the FirstSearch report, this facility formerly operated one 2,000-gallon oil UST and one 650-gallon oil UST.ECS reviewed regulatory files regarding this facility. During the removal of the USTs soil and groundwater contamination were identified.The contaminants identified included metals, chlorinated organic solvents and polyaromatic hydrocarbons.Contamination was discovered on the subject site (3405 South Tryon Street) along the eastern site boundary and in the creek bed.Soil remediation was completed in 2008. Groundwater source treatment has been conducted since 2005.Monitoring wells located on the subject site indicate elevated groundwater contaminants.The monitoring wells indicated that the groundwater flows radially from the facility towards the southwest, west and northwest.Additional remediation activities are planned for 2013.In October 2012,deep soil gas samples were collected on the subject site to evaluate the potential for vapor intrusion. The samples collected were below the state's industrial/commercial vapor intrusion levels.Based on contamination being identified on-site, ECS considers the release associated with this off-site facility to be an REC of the site. ·77 Corporate Park, Clanton Road & South Tryon Street -located approximately 150 feet southwest and topographically downgradient of the site. According to the FirstSearch report,oil and grease contamination was detected in the soil during redevelopment.The report indicates that the source is most likely the former junkyard that occupied the property prior to redevelopment. Based on groundwater flow direction inferred from surface topography, ECS ECS Project No. 08-8606 November 01, 2012 -12 - does not consider this facility to be an REC of the site. ·Acoustics, Inc., 3324 Pelton Street -located approximately 260 feet east and topographically upgradient of the site.According to the FirstSearch report, this facility formerly operated one 2,000-gallon gasoline UST.During the removal of the UST, minor soil contamination was detected.A No Further Action (NFA) was issued by the North Carolina Department of Environment and Natural Resources (NCDENR) on May 13, 1993.Based on the NFA issued by NCDENR, ECS does not consider this facility to be an REC of the site. The FirstSearch report identified an additional property within the search distance of inquiry. Based on the distance from the site and/or the presumed groundwater flow direction inferred from surface topography, ECS does not consider this facility to be RECs of the site. Leaking Underground Storage Tank (LUST) List The LUST list, maintained by NCDENR-Department of Waste Management (DWM), is a record of reported leaking underground storage tank incidents. The LUST list may also identify properties that have had soil and/or groundwater contamination associated with documented releases from aboveground storage tanks, surface spills and other sources. The site was not identified on the LUST list. One or more off-site properties within the minimum search distance of inquiry were reported as being on the LUST database. ·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing. ·Acoustics, Inc., 3324 Pelton Street -See IMD Listing. ·CATS Bus Maintenance & Operations Facility, 3251 South Tryon Street - located approximately 120 feet north and topographically crossgradient to downgradient of the site.According to the FirstSearch report, a release was reported on December 23, 2009.Based on the groundwater flow direction obtained from the monitoring wells located on-site, ECS does not consider this facility to be an REC of the site. The FirstSearch report identified an additional twenty properties within the search distance of inquiry. Based on the distance from the site and/or the presumed groundwater flow direction inferred from surface topography, ECS does not consider these facilities to be RECs of the site. Leaking Underground Storage Tanks (LUST TRUST) The LUST TRUST, maintained by NCDENR-DWM, contains information about claims against the State Trust Funds for reimbursements for expenses incurred while remediating Leaking USTs. The site was not identified on the Leaking Underground Storage Tank (LUST TRUST) list. ECS Project No. 08-8606 November 01, 2012 -13 - No off-site properties within the minimum search distance of inquiry were reported as being on the LUST TRUST database. Old Landfill Inventory (OLI) The OLI is maintained by the NCDENR. The inventory does not include no further action sites and other agency lead sites. The site was not identified on the OLI. No off-site properties within the minimum search distance of inquiry were reported as being on the OLI. Registered Underground Storage Tank (UST) List The Registered UST List inventories underground storage tanks registered with the NCDENR, Division of Water Quality. This list does not identify USTs that have not been registered with the NCDENR, such as home heating oil tanks and other unregulated tanks. The site was not identified on the Registered UST list. One or more off-site properties within the minimum search distance of inquiry were reported as being on the Registered UST list. ·Monarch Sprinkler, 308 Clanton Road -located on the adjoining property to the south and across a creek.According to the FirstSearch report, this facility formerly operated one 1,000-gallon gasoline UST.The UST was reportedly closed on October 1, 1988.Based on groundwater flow direction inferred from surface topography, ECS does not consider this facility to be an REC of the site. ·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing. Solid Waste Facilities/Historic Landfill List (HIST LF) State Historic Solid Waste Facility site records are maintained by the North Carolina Department of Environment and Natural Resource. The site was not identified on the HIST LF listing in the search report. No off-site properties within the minimum search distance of inquiry were reported as being on the HIST LF listing in the search report. Solid Waste Facilities/Landfill(SWL) List The North Carolina Solid Waste Section maintains a list of permitted solid waste facilities. These facilities may be active or inactive facilities or open dumps that failed to meet RCRA Subtitle D Section 4004 criteria for solid waste landfills or disposal sites. The site was not identified on the North Carolina SWL. No off-site properties within the minimum search distance of inquiry were reported as being on the North Carolina SWL. ECS Project No. 08-8606 November 01, 2012 -14 - State Brownfield Projects Inventory The State Brownfield Projects Inventory identifies brownfield projects inventoried with the North Carolina Department of Environment and Natural Resources (NCDENR). The properties in the inventory are working toward a brownfield agreement for cleanup and liability control. The site was not identified on the State Brownfield Projects Inventory. One or more off-site properties within the minimum search distance of inquiry were reported as being on the State Brownfield Projects Inventory. ·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing. The FirstSearch report identified an additional five properties within the search distance of inquiry. Based on the distance from the site and/or the presumed groundwater flow direction inferred from surface topography, ECS does not consider these facilities to be RECs of the site. State EC List The EC List identifies engineering controls including various forms of caps, building foundations, liners, and treatment methods used to eliminate pathways for regulated substances to enter environmental media or affect human health. The site was not identified on the State EC List. State Hazardous Substance Disposal Site (HSDS) The State HSDS records are locations of uncontrolled and unregulated hazardous waste sites. The records include sites on the NPL as well as those on the state priority list. The site was not identified on the HSDS list. No off-site properties within the minimum search distance of inquiry were reported as being on the HSDS. State Hazardous Waste Sites (SHWS) Inventory State hazardous waste site records are the states’ equivalent to CERCLIS. These sites may or may not be already listed on the federal CERCLIS database. The site was not identified on the SHWS Inventory. One or more off-site properties within the minimum search distance of inquiry were reported as being on the SHWS Inventory. ·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing. The FirstSearch report identified an additional seventeen properties within the search distance of inquiry. Based on the distance from the site and/or the presumed groundwater flow direction inferred from surface topography, ECS does not consider these facilities to be RECs of the site. ECS Project No. 08-8606 November 01, 2012 -15 - State Institutional Control (IC) List The State IC List identifies No Further Action facilities with land use restrictions monitoring requirements. The site was not identified on the State IC List. State Responsible Party Voluntary Action (VCP) Sites The VCP Sites is a listing of sites that parties wish to remediate voluntarily. The program is administered by the NCDENR. The site was not identified on the VCP Sites list. One or more off-site properties within the minimum search distance of inquiry were reported as being on the VCP Sites list. ·Pelton & Crane Plant (Former), 200 Clanton Road -See IMD Listing. State Unmapped (Orphan) Facilities and Sites Several properties were identified on the Orphan Summary List prepared by FirstSearch. These facilities are considered by FirstSearch as unmappable because the facility information in the database is insufficient and does not report accurate facility location information. The site was not identified on the Unmapped (Orphan) Facilities and Sites. No off-site properties within the minimum search distance of inquiry were reported as being on the Unmapped (Orphan) Facilities and Sites. Drycleaners The Drycleaners database identifies potential and known drycleaning sites, active and abandoned. The site was not identified on the Drycleaners database. No off-site properties within the minimum search distance of inquiry were reported as being on the Drycleaners database. 5.3 Historical Use Information Sanborn Fire Insurance Map Review Historic Fire Insurance Maps (i.e., Sanborns) were obtained from The University of North Carolina at Chapel Hill, University Libraries Digital Collections (via the internet). ECS reviewed maps from 1884 to 1910. According to the FirstSearch report, Sanborn maps were available for the area; however, the subject site was not covered on the Sanborns. ECS Project No. 08-8606 November 01, 2012 -16 - Aerial Photograph Review ECS reviewed aerial photographs of the site and immediately surrounding properties for evidence of former usage which may constitute a potential for environmental concern. The aerial photographs were obtained from the Mecklenburg County Natural Resource Conservation Service, Mecklenburg County Geographic Information Systems (GIS) Department and Google Earth. The aerial photographs reviewed were dated 1938, 1951, 1956, 1966, 1968, 1975, 1978, 1980, 1983, 1986, 1990, 1993, 1998, 2002, 2005 and 2010.Aerial photographs dated prior to 1938 were not available for review. On the 1938 aerial photograph, the site appears to be cleared land.Surrounding properties contain single family residences and cleared and wooded land.The site is bounded to the west by South Tryon Street.South Boulevard is located to the east of the site and Clanton Road is located south of the site. On the 1951 aerial photograph, the site is wooded.Commercial development is located to the east of the site along South Boulevard.Additional single family residences are located to the south along South Tryon Street. On the 1956 aerial photograph, the site is partially wooded.Commercial development is located on the adjoining properties to the east and south of the site.Additional commercial development is located to the north of the site. On the 1966 and 1968 aerial photographs, the site appears to be cleared.Commercial development is located to the east along Pelton Street and south of the site along Clanton Road.A vehicle storage lot is located to the west of the site at the intersection of South Tryon Street and Clanton Road. On the 1975 aerial photograph, the site is partially wooded.Additional commercial development is located to the west of the site and to the south of the site along Clanton Road. On the 1978 and 1980 aerial photographs, the site appears similar to the 1975 aerial photograph.The vehicle storage lot to the west is cleared and vacant. On the 1983, 1986 and 1990 aerial photographs, the site appears similar to the 1980 aerial photograph.Commercial development is located to the west of the site at the intersection of South Tryon Street and Clanton Road. On the 1993, 1998 and 2002 aerial photographs, the site is developed with a commercial building consistent with the current facility. Surrounding areas appear similar to the 1990 aerial photograph. On the 2005 aerial photograph, the site appears similar to the 2002 aerial photograph. Commercial development consistent with the CATS bus facility is located to the north of the site. On the 2010 aerial photograph, the site and surrounding areas appear consistent with conditions observed during the site reconnaissance. ECS Project No. 08-8606 November 01, 2012 -17 - ECS considers the lack of aerial photographs dated in excess of ten year intervals to be a data failure (historical data gap). City Directory Review One of the ASTM standard historic sources to be reviewed for previous site use are local street directories, commonly known as City Directories.The purpose of the directory review is to identify past occupants of the site, adjoining properties, or nearby properties.In some rural areas, street directories information is limited. The Charlotte city directories dated 1940, 1945, 1950, 1955, 1959, 1967, 1971, 1975, 1980, 1984, 1992, 1995, 2000, 2005 and 2012 were obtained from the Mecklenburg County Public Library. ECS reviewed listings for South Tryon Street, Clanton Road and Pelton Street. The purpose of the city directory review is to identify past occupants of the site and immediately surrounding properties. Site Listings -The site is listed as Carolina Marking Devices, Inc. and Caromark Stamps and Signs in the 2005 city directory. In the 2000, 1995 and 1992 city directories, the site is listed as Carolina Marking Devices, Inc. The site is not listed in city directories dated prior to 1992. South Tryon Street -Listings included Jackson Roofing, Neal Properties, Charlotte Area Transit Systems, Fast Signs, A Bedder Bedder, Carolina Concrete Pumping, Quality Dry Cleaning (approximately 780 feet southwest and topographically downgradient), Fina Oil Company (approximately 400 feet southwest and topographically downgradient) and single family residences. The property located at 3419 South Tryon Street (approximately 100 feet south and located across a creek) was listed as Bonded Oil gasoline station in 1967, Professional Oil gasoline station in 1971, Adam’s Garage in 1975, H&M Auto from 1980 to 1990 and as Cecil’s Auto Repair from 1995 to 2005. Based on the groundwater flow direction inferred from surface topography, ECS does not consider this property to be an REC of the site. Clanton Road -Listings included Hertron International, LLC (adjoining property to the south and across a creek), Staff Zone, SFI Electronics, Scooter Store, FN Thompson General Contractors, Lifespan Manufacturers, WB & Associate Inc of Charlotte, New South Drywall Contracting, Automotive Parts Express Inc., Sid Harvey Hasko Inc, Catawba Industrial Rubber Company, Superior Tile Marble and Terrazzo, Chain Belt Company and Pelton & Crane Company. Pelton & Crane Company is located on the adjoining property to the east and was listed from 1959 until 1992. Additional details regarding this facility are discussed in Section 5.2. Pelton Street -Listings included Triangle Fastener Corporation, Acoustics Incorporated, Engineering Sales Associates, Edwards Enterprises-Carolina, Laufen International, Threadline Products Incorporated, Pan Glo Charlotte, Tubelite Company Incorporated, Middlebury Mouldings, and Exotic Pet Supply. ECS considers the lack of city directories dated in excess of five year intervals to be a data failure (historical data gap). ECS Project No. 08-8606 November 01, 2012 -18 - Other Standard Historical Sources In accordance with the ASTM Standard, other historical sources should be reviewed, if necessary and if the information is likely to be useful, to obtain historical site use information. Other Standard Historical Sources may include property tax files, recorded land title records, historic USGS topographic maps, building department records, and zoning or land use records. ECS obtained tax information regarding the subject site from Mecklenburg County tax information via the internet. According to the tax information, the property is identified as tax Parcel ID No. 14702131.The owner of the parcel is Solomon Shapiro. Other Local Historical Sources Other credible historical sources may be reviewed to identify past uses of the property. These sources may include internet sites, county or State road maps, historical society documents, or local library information. ECS obtained tax information about the site from the Mecklenburg County GIS department (via the internet). ECS obtained city directories from the Mecklenburg County Public Library as discussed in the City Directories section in Section 5.4. Freedom of Information (FOIA)Requests ECS contacted Mr. Garry McCormick, Hazardous Material Coordinator with the Charlotte Mecklenburg County Fire Department regarding reported incidents of spills and environmental issues associated with the site and surrounding area. At the time of this report, ECS has not received a response from the Charlotte Mecklenburg Fire Department. ECS considers the lack of fire department information to be a data gap. An addendum will be issued if ECS receives a response at a later date that indicates a material difference in ECS’s findings. ECS Project No. 08-8606 November 01, 2012 -19 - 6.0 SITE AND AREA RECONNAISSANCE 6.1 Methodology and Limiting Conditions Mr. David E. Valentine of ECS conducted the field reconnaissance on October 10, 2012. The weather at the time of the reconnaissance was approximately 60 degrees Fahrenheit and sunny. Observations were made from a walking reconnaissance around the perimeter boundary and several transects through the site and building. Photographs, taken at the time of the site reconnaissance, are included in Appendix V. 6.2 On-Site Features The site is an approximate 3.03 acre tract located at 3405 South Tryon Street in Charlotte, Mecklenburg County, North Carolina.The site is developed with an approximate 24,000 square foot, one-story commercial warehouse.The building was constructed in 1991 and was formerly occupied by Carolina Marking Devices, Inc.The site was used for production of marking devices (stamps, badges, notary seals, etc.) that utilized various inks.The building contains a showroom, offices, a production area and a warehouse.The remainder of the site consists of an asphalt paved parking lot and landscaped areas.The site is provided water and sanitary sewer services through the Charlotte Mecklenburg Utilities Department.The site is provided natural gas through Piedmont Natural Gas. Underground or aboveground storage tanks We did not observe aboveground storage tanks or evidence of underground storage tanks at the site. Strong, pungent or noxious odors We did not notice strong, pungent or noxious odors at the site. Surface waters The following observations were made with regard to surface waters on the site: ECS observed a creek along the southern site boundary.Sheens, indicative of petroleum byproducts, was not observed on the surface of the water. Standing pools of liquid likely containing petroleum or hazardous substances We did not observe standing pools of liquid at the site. Drums or containers of petroleum or hazardous substances greater than five- gallons We did not observe drums or containers of petroleum or hazardous substances greater than five-gallons at the site. Drums or containers of petroleum or hazardous substances less than or equal to five-gallons The following observations were made with regard to drums or containers of petroleum ECS Project No. 08-8606 November 01, 2012 -20 - or hazardous substances less than or equal to five-gallons at the site: ECS observed various paint containers located in the warehouse.There was no visual evidence that the containers had leaked or the material had been spilled. Unidentified opened or damaged containers of hazardous substances or petroleum products We did not observe unidentified opened or damaged containers of hazardous substances or petroleum products at the site. Known or suspect PCB-containing equipment (excluding light ballasts) The following observations were made with regard to known or suspect PCB-containing equipment on the site: ECS observed one pad mounted transformer located on-site.The transformer is owned and maintained by Duke Energy.Staining was not observed on the ground surface in the vicinity of the transformer. Stains or corrosion to floors, walls or ceilings The following observations were made with regard to stains or corrosion to floors, walls or ceilings: ECS observed two air compressors in the building that were leaking oil.The oil appeared to have traveled into cracks in the concrete flooring.ECS considers the oil from the air compressors to be an REC of the site. ECS observed staining on the concrete in the ink storage room.The concrete appeared to be in good condition. Floor drains and sump pumps The following observations were made with regard to floor drains or sump pumps at the site: ECS observed a floor drain in the production area of the building.A wash basin is located next to the drain with a pipe running into the drain.The facility was not listed in the regulatory database as having a wastewater discharge permit and was not listed as having records of incidents. Pits, ponds or lagoons We did not observe pits, ponds or lagoons at the site. Stained soil or pavement We did not observe stained soils or pavement at the site. Stressed vegetation We did not observe stressed vegetation at the site. Solid waste mounds or non-natural fill materials We did not observe solid waste mounds or non-natural fill materials at the site. ECS Project No. 08-8606 November 01, 2012 -21 - Wastewater discharges into drains, ditches or streams We did not observe wastewater discharges at the site. Groundwater wells including potable, monitoring, dry, irrigation, injection and/or abandoned The following observations were made with regard to groundwater wells at the site: ECS observed five groundwater monitoring wells located on the site.The monitoring wells are associated with on-going remediation activities from the former Pelton & Crane facility as discussed in Section 5.2.ECS considers these monitoring wells to be RECs of the site. Septic systems or cesspools We did not observe evidence of septic systems or cesspools on the site. Elevators We did not observe elevators on the site. Dry Cleaning We did not observe dry-cleaning operations on the site. Onsite Emergency Electrical Generators We did not observe emergency generators on the site. 6.3 Adjoining and Nearby Properties Contiguous and nearby properties were observed during a walking and vehicular reconnaissance of the property boundary and public places.The site is located in a commercial/residential area of Charlotte, North Carolina. The site is bounded on the north by CATS bus facility with additional commercial development located further north. The site is bounded on the east by goodmortgage.com and Lifespan with additional commercial buildings and single family residences located further east. The site is bounded on the south by USTT, Hertron, Staffzone and C.A.R.S. with additional commercial development located further south. The site is bounded on the west by South Tryon Street, 77 Corporate Park and Fast Signs with additional commercial buildings and single family development located further west. ECS Project No. 08-8606 November 01, 2012 -22 - 7.0 ADDITIONAL SERVICES 7.1 Non-Scope Issues ASTM guidelines identify non-scope issues, which are beyond the scope of this practice. Non-scope issues have the potential to be business environmental risks. Some of these non-scope issues include; asbestos-containing building materials, radon, lead-based paint, lead in drinking water, wetlands and mold. We were not authorized to conduct non-scope services for the site. 7.2 Previous Reports Review We have conducted the following environmental and/or engineering assessment(s) for the site: ECS conducted a Property Condition Assessment for the subject site. Findings from the report are included under a separate cover, ECS Project No. 08-8606A, dated October 2012. We have not been provided with environmental or engineering assessment reports for the site completed by others. ECS Project No. 08-8606 November 01, 2012 -23 - 8.0 INTERVIEWS ECS spoke with Mr. Greg Pappanastos, President of Argos Real Estate Advisors and representative of the owner of the site.Mr. Pappanastos indicated that the site was formerly occupied with Carolina Marking Devices, Inc.Mr. Pappanastos indicated that the former tenant had occupied the site from 1991 to 2012.Mr. Pappanastos indicated that he is unaware of past operations on the site that would be considered an environmental concern for the site.Mr. Pappanastos indicated that the former Pelton & Crate Company facility (adjoining property to the east) was currently undergoing remediation activities and that contamination from the facility had been detected on the subject site.Mr. Pappanastos provided ECS with regulatory documents related to the remediation activities.Mr. Pappanastos indicated that he is unaware of USTs or environmental concerns associated with the subject site. ECS attempted to contact the Charlotte Mecklenburg Utilities Department regarding the subject site.At the time of this report, ECS has not recieved a response deom the Charlotte Mecklenburg Utilities Department.An addendum will be issued if ECS receives a response at a later date that indicates a material difference in ECS’ findings. ECS contacted Mr. Garry McCormick, Hazardous Material Coordinator with the Charlotte Mecklenburg County Fire Department regarding reported incidents of spills and environmental issues associated with the site and surrounding area. At the time of this report, ECS has not received a response from the Charlotte Mecklenburg Fire Department. ECS considers the lack of fire department information to be a data gap. An addendum will be issued if ECS receives a response at a later date that indicates a material difference in ECS’ findings. ECS Project No. 08-8606 November 01, 2012 -24 - 9.0 FINDINGS The site is an approximate 3.03 acre tract located at 3405 South Tryon Street in Charlotte, Mecklenburg County, North Carolina.The site is developed with an approximate 24,000 square foot, one-story commercial warehouse.The building was constructed in 1991 and was formerly occupied by Carolina Marking Devices, Inc.The site was used for production of marking devices (stamps, badges, notary seals, etc.) that utilized various inks.The building contains a showroom, offices, a production area and a warehouse.The remainder of the site consists of an asphalt paved parking lot and landscaped areas.The site is provided water and sanitary sewer services through the Charlotte Mecklenburg Utilities Department.The site is provided natural gas through Piedmont Natural Gas.ECS did not observe USTs associated with the site. ECS observed two air compressors in the building that were leaking oil.The oil appeared to have traveled into cracks in the concrete flooring.ECS considers the oil from the air compressors to be an REC of the site. ECS observed five groundwater monitoring wells located on the site.The monitoring wells are associated with on-going remediation activities from the former Pelton & Crane facility as discussed in Section 5.2.ECS considers these monitoring wells to be RECs of the site. ECS reviewed historical aerial photographs and city directories for the subject site and surrounding areas.The aerial photograph review depicted the site to be historically undeveloped until the current facility was constructed in 1991.Surrounding properties were historically developed with residential and commercial structures.The site is listed as Carolina Marking Devices, Inc. and Caromark Stamps and Signs in the 2005 city directory. In the 2000, 1995 and 1992 city directories, the site is listed as Carolina Marking Devices, Inc. The site is not listed prior to the 1992 city directories.The site is currently bounded on the north by CATS bus facility; on the east by goodmortgage.com and Lifespan; on the south by USTT, Hertron, Staffzone and C.A.R.S.; and, on the west by South Tryon Street, 77 Corporate Park and Fast Signs. The site is located in a commercial/residential area of Charlotte, North Carolina. A regulatory records search report, dated October 8, 2012 of ASTM standard and supplemental databases was prepared for the site by FirstSearch. FirstSearch identified multiple properties within the search distance of inquiry and one to be of environmental concern with respect to the site: ·Pelton & Crane Plant (Former), 200 Clanton Road -located on the adjoining property to the east and topographically upgradient of the site.According to the FirstSearch report, this facility formerly operated one 2,000-gallon oil UST and one 650-gallon oil UST.ECS reviewed regulatory files regarding this facility. During the removal of the USTs soil and groundwater contamination were identified.The contaminants identified included metals, chlorinated organic solvents and polyaromatic hydrocarbons.Contamination was discovered on the subject site (3405 South Tryon Street) along the eastern site boundary and in the creek bed.Soil remediation was completed in 2008. Groundwater source ECS Project No. 08-8606 November 01, 2012 -25 - treatment has been conducted since 2005.Monitoring wells located on the subject site indicate elevated groundwater contaminants.The monitoring wells indicated that the groundwater flows radially from the facility towards the southwest, west and northwest.Additional remediation activities are planned for 2013.In October 2012,deep soil gas samples were collected on the subject site to evaluate the potential for vapor intrusion. The samples collected were below the state's industrial/commercial vapor intrusion levels.Based on contamination being identified on-site, ECS considers the release associated with this off-site facility to be an REC of the site. ECS Project No. 08-8606 November 01, 2012 -26 - 10.0 CONCLUSIONS AND OPINIONS ECS has performed a Phase I Environmental Site Assessment in conformance with the scope and limitations of ASTM Practice E 1527-05 of the site located at 3405 South Tryon Street in Charlotte, Mecklenburg County, North Carolina.Any exceptions to, or deletions from, this practice are described in Section 2.3 of this report. As documented and qualified by this report, this assessment has revealed the following evidence of RECs in connection with the property: On-Site: Potential exists that the discharge oil from the air compressors could impact soil and/or groundwater beneath the site.ECS recommends additional assessment to determine if soil and/or groundwater beneath the site has been impacted. ECS observed five groundwater monitoring wells on-site that are associated with on- going remediation activities at the former Pelton & Crane facility located on the adjoining property to the east. Off-Site: The former Pelton & Crane facility located on the adjoining property to the east is currently undergoing remediation activities.ECS recommends that the responsible party continue with remediation activities for the former Pelton & Crane facility.ECS also recommends requesting and periodically reviewing sampling and reporting conducted by the responsible party and having a qualified environmental professional review the findings. ECS Project No. 08-8606 November 01, 2012 -27 - 11.0 REFERENCES Mecklenburg County NRCS Department, Aerial Photographs dated 1938, 1951, 1956, 1968 and 1983. Mecklenburg County GIS Department, Aerial Photographs dated 1966, 1975, 1978, 1980, 1983, 1986, 1990 and 1997. Google Earth, Aerial Photographs dated 1993, 1998, 2002, 2005 and 2010. Mecklenburg County City Directories, dated 1940, 1945, 1950, 1955, 1959, 1967, 1971, 1975, 1980, 1984, 1992, 1995, 2000, 2005 and 2012. FirstSearch Report dated October 8, 2012. Geologic Map of North Carolina, compiled by the North Carolina Geological Society, dated 1985. USGS Topographic Map, Charlotte West, North Carolina Quadrangle Dated 1993. USGS Topographic Map, Charlotte East, North Carolina Quadrangle Dated 1967. APPENDIX I FIGURES FIGURE 1 SITE LOCATION MAP Carolina Marking Devices, Inc. 3405 South Tryon St. Charlotte, Mecklenburg County, North Carolina ECS Project No. 08-8606 SOURCE: USGS TOPOGRAPHIC MAP: Charlotte West, Dated 1993 Charlotte East, Dated 1967 North Carolina Quadrangles Scale: 1” ~ 2,000’ SITE LEGEND 1 – Unity Auto Sales 2 – CATS Bus Facility 3 – Goodmortgage.com 4 – Lifespan (Former Pelton & Crane Co.) 5 – Engineering Sales Associates 6 – AEC 7 – USTT 8 – Hertron – Monitoring Well – LUST Incident SOURCE: Google Earth (via the Internet) Scale as Shown FIGURE 2 2010 AERIAL PHOTOGRAPH Carolina Marking Devices, Inc. 3405 South Tryon Street Charlotte, Mecklenburg County, North Carolina ECS Project No. 08-8606 2 4 1 315 5 6 7 8 9 16 11 10 12 13 14 9 – Staff Zone 10 – C.A.R.S 11 – Heineman 12 – Carolina Wood Flooring 13 – Retail Center 14 – Carolina Auto House 15 – 77 Corporate Park 16 – Fast Signs APPENDIX II CORRESPONDENCE AND USER QUESTIONNAIRE APPENDIX III REGULATORY RECORDS DOCUMENTATION ENVIRONMENTAL FIRSTSEARCH REPORT TARGET PROPERTY: 3405 SOUTH TRYON ST. 3405 S TRYON ST CHARLOTTE, NC 28217 JOB NUMBER: 8606 PREPARED FOR: ECS Carolinas, LLP 1812 Center Park Drive, Suite D Charlotte, NC 28217 October 8, 2012 Environmental FirstSearch Search Summary Report Target Site:3405 S TRYON ST CHARLOTTE, NC 28217 FirstSearch Summary Notice of Disclaimer Waiver of Liability Database Sel Updated Radius Site 1/8 1/4 1/2 1/2> ZIP TOTALS NPL Y 09-20-12 1.00 0 0 0 0 0 0 0 NPL Delisted Y 09-20-12 0.50 0 0 0 0 -0 0 CERCLIS Y 08-01-12 0.50 0 0 0 0 -1 1 NFRAP Y 08-01-12 0.50 0 0 0 4 -1 5 RCRA COR ACT Y 09-11-12 1.00 0 0 0 0 0 0 0 RCRA TSD Y 09-11-12 0.50 0 0 0 0 -0 0 RCRA GEN Y 09-11-12 0.25 0 0 5 --0 5 Federal Brownfield Y 07-15-12 0.50 0 0 0 2 -0 2 ERNS Y 10-04-12 0.12 0 0 ---1 1 Tribal Lands Y 12-15-08 1.00 0 0 0 0 0 1 1 State/Tribal Sites Y 06-08-12 1.00 0 1 1 8 9 1 20 State Spills 90 Y 06-01-12 0.12 0 4 ---0 4 State Spills 80 Y 06-14-01 0.25 0 0 1 --0 1 State/Tribal SWL Y 05-26-11 0.50 0 0 0 0 -8 8 State/Tribal LUST Y 06-01-12 0.50 0 4 3 20 -4 31 State/Tribal UST/AST Y 06-01-12 0.25 0 7 9 --0 16 State/Tribal EC Y NA 0.50 0 0 0 0 -0 0 State/Tribal IC Y 06-08-12 0.25 0 0 0 --0 0 State/Tribal VCP Y 07-30-07 0.50 0 1 0 0 -0 1 State/Tribal Brownfields Y 08-10-12 0.50 0 3 0 6 -1 10 State Other Y 06-24-10 0.25 0 0 0 --0 0 Federal IC/EC Y 09-18-12 0.50 0 0 0 0 -0 0 Dry Cleaners Y 05-21-12 0.25 0 0 0 --0 0 -TOTALS-0 20 19 40 9 18 106 Due to the limitations, constraints, and inaccuracies and incompleteness of government information and computer mapping data currently available to FirstSearch Technology Corp., certain conventions have been utilized in preparing the locations of all federal, state and local agency sites residing in FirstSearch Technology Corp.'s databases. All EPA NPL and state landfill sites are depicted by a rectangle approximating their location and size. The boundaries of the rectangles represent the eastern and western most longitudes; the northern and southern most latitudes. As such, the mapped areas may exceed the actual areas and do not represent the actual boundaries of these properties. All other sites are depicted by a point representing their approximate address location and make no attempt to represent the actual areas of the associated property. Actual boundaries and locations of individual properties can be found in the files residing at the agency responsible for such information. Although FirstSearch Technology Corp. uses its best efforts to research the actual location of each site, FirstSearch Technology Corp. does not and can not warrant the accuracy of these sites with regard to exact location and size. All authorized users of FirstSearch Technology Corp.'s services proceeding are signifying an understanding of FirstSeaarch Technology Corp.'s searching and mapping conventions, and agree to waive any and all liability claims associated with search and map results showing incomplete and or inaccurate site locations. Environmental FirstSearch Site Information Report Request Date:10-08-12 Search Type:COORD Requestor Name:Louise Bhavnani Job Number:8606 Standard:AAI Filtered Report Target Site:3405 S TRYON ST CHARLOTTE, NC 28217 Demographics Sites:106 Non-Geocoded:18 Population:NA Radon:NA Fire Insurance Map Coverage:Yes Site Location Degrees (Decimal) Degrees (Min/Sec) UTMs Longitude:-80.875927 -80:52:33 Easting:511294.955 Latitude:35.196858 35:11:49 Northing:3894683.119 Elevation:721 Zone:17 Comment Comment: Additional Requests/Services Adjacent ZIP Codes:Services: ZIP Code City Name ST Dist/Dir Sel Requested? Date Fire Insurance Maps No Aerial Photographs No Historical Topos No City Directories No Title Search No Municipal Reports No Liens No Historic Map Works No Online Topos No Environmental FirstSearch Target Site Summary Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0 No sites found for target address Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No. Environmental FirstSearch Sites Summary Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0 Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No. 1 UST MONARCH SPRINKLER 308 CLANTON RD 0.08 SW - 1 1 0-014170/PERM CLOSED REMOVED CHARLOTTE NC 28210 2 STATE PELTON & CRANE PLANT (FORMER)200 CLANTON RD 0.10 SE + 30 2 NCD055162069/ACTIVE CHARLOTTE NC 2 SPILLS CLANTON ROAD FACILITY 200 CLANTON RD 0.10 SE + 30 3 15846/CLOSED OUT CHARLOTTE NC 2 SPILLS PELTON & CRANE PLANT (FORMER,200 CLANTON RD 0.10 SE + 30 4 85670/NOD CHARLOTTE NC 2 UST CLANTON ROAD FACILITY 200 CLANTON RD 0.10 SE + 30 5 MO-4766/CHARLOTTE NC 28217 2 UST THE PELTON & CRANE CO.200 CLANTON RD 0.10 SE + 30 7 0-014524/PERM CLOSED REMOVED CHARLOTTE NC 28210 2 LUST CLANTON ROAD FACILITY 200 CLANTON RD 0.10 SE + 30 10 NCI-015846/CLOSED OUT CHARLOTTE NC 28217 2 LUST PELTON & CRANE PLANT (FORMER)200 CLANTON RD 0.10 SE + 30 11 NCI-085670/NOD CHARLOTTE NC 2 BROWNFIE FORMER PELTON & CRANEPLANT 200 CLANTON RD 0.10 SE + 30 12 NCBR-0206-047/ACTIVE CHARLOTTE NC 2 BROWNFIE PELTON & CRANE PLANT 200 CLANTON RD 0.10 SE + 30 13 NCBR-1106-033/FINALIZED CHARLOTTE NC 2 BROWNFIE PELTON AND CRANE PLANT - FORMER 200 CLANTON RD 0.10 SE + 30 14 09034-05-60/FINALIZED CHARLOTTE NC 2 VCP PELTON & CRANE PLANT (FORMER)200 CLANTON RD 0.10 SE + 30 15 VC-NCD055162069/VOLUNTARY CLEANUP CHARLOTTE NC 3 SPILLS 77 CORPORATE PARK CLANTON ROAD, SOUTH TRYON 0.10 SW + 3 16 86378/CURRENT RECORD CHARLOTTE NC 28217 4 SPILLS ACOUSTICS, INC.3324 PALTON ST 0.11 SE + 37 17 10174/CLOSED OUT CHARLOTTE NC 4 UST ACOUSTICS INCORPORATED 3324 PELTON ST 0.11 SE + 37 18 0-026559/PERM CLOSED REMOVED CHARLOTTE NC 28217 4 UST ACOUSTICS, INC.3324 PELTON ST 0.11 SE + 37 21 MO-3782/CHARLOTTE NC 28217 4 LUST ACOUSTICS, INC.3324 PALTON ST 0.11 SE + 37 23 NCI-010174/CLOSED OUT CHARLOTTE NC 28217 5 UST CATS BUS M AND O 3251 S TRYON ST 0.12 NE + 3 24 0-03679/UNKNOWN CHARLOTTE NC 28217 5 UST CATS BUS MAINTENANCE AND OPS FAC 3251 S TRYON ST 0.12 NE + 3 26 0-036729/CURRENTLY OPERATIONAL CHARLOTTE NC 28217 5 LUST CATS BUS M AND O 3251 S TRYON ST 0.12 NE + 3 29 NCI-036749/CURRENT RECORD CHARLOTTE NC 28217 Environmental FirstSearch Sites Summary Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0 Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No. 6 UST JOE B. WILLIAMS PROPERTY 3500 S TRYON ST 0.13 SW + 9 30 MO-4083/UNKNOWN CHARLOTTE NC 28217 6 LUST JOE B. WILLIAMS PROPERTY 3500 S STRYON ST 0.13 SW + 9 32 NCI-012153/CLOSED OUT CHARLOTTE NC 28217 7 UST 3206 SOUTH TRYON 3206 S TRYON ST 0.13 NE - 19 33 MO-2336/UNKNOWN CHARLOTTE NC 28217 8 RCRAGN ALTEC INDUSTRIES, INC 3335 PELTON ST 0.18 SE + 46 35 NCD986232510/SGN CHALOTTE NC 28220 9 UST BARCLAYS CAPITAL 3417 TRADE PARK CT 0.18 NW - 5 36 MO-180/CHARLOTTE NC 28217 9 UST BARCLAYS CAPITAL 3417 TRADE PARK CT 0.18 NW - 5 38 MO-0180/UNKNOWN CHARLOTTE NC 28217 9 UST BARCLAYS CAPITAL, INC.3417 TRADE PARK CT 0.18 NW - 5 40 0-035914/PERM CLOSED REMOVED CHARLOTTE NC 28217 10 RCRAGN CATS-BOD S TRYON BUS GARAGE 3145 S TRYON ST 0.19 NE - 4 41 NC0991302662/VGN CHARLOTTE NC 28202 11 RCRAGN PROVIDENCE PAINT CO 428 BLAIRHILL RD 0.19 SW + 6 43 NCR000143172/SGN CHARLOTTE NC 28217 12 RCRAGN PURE CLEAN 3601 S TRYON ST 0.20 SW + 6 45 NCD982163180/SGN CHARLOTTE NC 28205 13 STATE AMERICAN FENCE SOLVENTS 3605 S TRYON ST 0.20 SW + 5 46 NONCD0001255/ACTIVE CHARLOTTE NC 13 UST AMERICAN FENCE 3605 S TRYON ST 0.20 SW + 5 47 MO-7007/UNKNOWN CHARLOTTE NC 28217 13 LUST AMERICAN FENCE 3605 S TRYON ST 0.20 SW + 5 49 NCI-027713/CLOSED OUT CHARLOTTE NC 28217 14 RCRAGN ARTS ENGRAVING CO INC 3136 MAY ST 0.21 NW - 39 50 NCD003151701/VGN CHARLOTTE NC 28217 15 SPILLS80 CANTEEN CO.3621 TRYCLAN RD 0.22 SW + 4 52 6923/RESPONSE CHARLOTTE NC 15 LUST CANTEEN FOOD SERVICES 3621 TRYCLAN RD 0.22 SW + 4 53 NCI-006923/RESPONSE CHARLOTTE NC 28217 16 UST CANTEEN CORPORATION 3631 TRYCLAN DR 0.22 SW + 3 54 0-014703/PERM CLOSED REMOVED CHARLOTTE NC 28210 16 UST CANTEEN FOOD SERVICES 3631 TRYCLAN DR 0.22 SW + 3 55 MO-3117/UNKNOWN CHARLOTTE NC 28217 17 UST F N THOMPSON INC 201 CLANTON RD 0.22 SE + 30 57 0-002592/PERM CLOSED REMOVED CHARLOTTE NC 28232 18 LUST CATS MAINTENANCE FACITLITY 3200 SOUTH BLVD 0.27 SE + 41 60 NCI-027904/CLOSED OUT CHARLOTTE NC 28209 Environmental FirstSearch Sites Summary Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0 Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No. 19 STATE CITY OF CHARLOTTE-SCALEYBARK SITE 3610 SOUTH BLVD 0.30 SE + 34 61 NONCD0002805/ACTIVE CHARLOTTE NC 20 LUST CONOCO STORE #33066 605 CLANTON RD 0.30 NW 0 62 NCI-011918/CLOSED OUT CHARLOTTE NC 28217 21 LUST PEPSI-COLA 3101 GRIFFITH ST 0.33 NE + 29 63 NCI-009747/CLOSED OUT CHARLOTTE NC 28203 22 LUST SERVCO #01613 3040 SOUTH BLVD 0.33 NE + 30 64 NCI-027648/CURRENT RECORD CHARLOTTE NC 28209 22 LUST SERVCO STATION/S. BLVD 3040 SOUTH BLVD 0.33 NE + 30 65 NCI-008796/CLOSED OUT CHARLOTTE NC 28209 23 NFRAP WILLIARD SMELTING CO.101 NEW BERN ST 0.35 NE + 35 66 NCD003151651/NFRAP-N CHARLOTTE NC 28203 23 STATE WILLARD SMELTING CO.101 NEW BERN ST 0.35 NE + 35 67 NCD003151651/ACTIVE CHARLOTTE NC 23 LUST WILLARD INDUSTRIES (FORMER)101 NEW BERN ST 0.35 NE + 35 68 NCI-017690/CLOSED OUT CHARLOTTE NC 28203 23 LUST WILLARD SMELTING CO 101 NEW BERN ST 0.35 NE + 35 69 NCI-085678/NOD CHARLOTTE NC 23 BROWNFIE WILLARD LEAD FACILITY 101 NEW BERN ST 0.35 NE + 35 70 NCBR-0206-087/FINALIZED CHARLOTTE NC 24 NFRAP BORDEN CHEMICAL PRINTING INK 3013 GRIFFITH ST 0.36 NE + 31 71 NCD049774375/NFRAP-N CHARLOTTE NC 28203 24 STATE BORDEN CHEMICAL PRINTING INK 3013 GRIFFITH ST 0.36 NE + 31 72 NCD049774375/NFA CHARLOTTE NC 25 NFRAP PIEDMONT HEAT TREATING CORP 3311 GRIFFITH ST 0.36 NE + 6 73 NCD066309113/NFRAP-N CHARLOTTE NC 28203 25 STATE PIEDMONT HEAT TREATING CORP 3311 GRIFFITH ST 0.36 NE + 6 74 NCD066309113/NFA CHARLOTTE NC 26 LUST EPMORE INC.2941 S TRYON ST 0.37 NE + 17 75 NCI-015304/RESPONSE CHARLOTTE NC 28203 27 BROWNFIE RUSAK PROPERTY 3004 BANK ST 0.38 NE + 5 76 NCBR-0038/FINALIZED CHARLOTTE NC 28 STATE NIVENS PROPERTY 3022 GRIFFITH ST 0.38 NE + 38 77 NONCD0002204/ACTIVE CHARLOTTE NC 28 LUST FLOORING CONCEPTS 3022 GRIFFITH ST 0.38 NE + 38 78 NCI-027262/CLOSED OUT CHARLOTTE NC 28203 29 BROWNFIE RUSAK PROPERTY 3331 GRIFFITH ST 0.38 NE - 10 79 NCBF-0811-003/FINALIZED CHARLOTTE NC 30 LUST MRS. J. SPENCER BELL/WF (RP-D)111 NEW BERN ST 0.40 NE + 39 80 NCI-005176/RESPONSE CHARLOTTE NC 28203 Environmental FirstSearch Sites Summary Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0 Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No. 31 BROWNFIE BROWN S SOLVENT CO 2935 GRIFFITH ST 0.40 NE + 34 81 NCBR-0010/FINALIZED CHARLOTTE NC 31 BROWNFIE BROWN S SOLVENT CO.2935 GRIFFITH ST 0.40 NE + 34 82 05006-01-60/FINALIZED CHARLOTTE NC 31 FEDBROWN BROWN S SOLVENT COMPANY 2935 GRIFFITH ST 0.40 NE + 34 83 55781569-16/EPA BROWNFIELD CHARLOTTE NC 31 FEDBROWN BROWN S SOLVENT COMPANY 2935 GRIFFITH ST 0.40 NE + 34 85 13562/EPA BROWNFIELD CHARLOTTE NC 28203 32 BROWNFIE WILLARD LEAD RIGHT-OF-WAY 122 NEW BERN ST 0.40 NE + 38 87 15014-11-60/FINALIZED CHARLOTTE NC 33 LUST DIXIE WRECKER 3801 SOUTH BLVD 0.42 SE + 31 88 NCI-036241/CURRENT RECORD CHARLOTTE NC 28217 34 NFRAP SWIFT ADHESIVES & COATINGS 2917 YOUNGBLOOD ST 0.43 NE + 41 89 NCD980557763/NFRAP-N CHARLOTTE NC 28203 34 STATE SWIFT ADHESIVES & COATINGS/CHARLOT 2917 YOUNGBLOOD ST 0.43 NE + 41 90 NCD980557763/NFA CHARLOTTE NC 35 STATE TERRELL MACHINE SHOP 3000 SOUTH BLVD 0.43 NE + 27 91 NONCD0000011/ACTIVE CHARLOTTE NC 35 LUST TERRELL MACHINE COMPANY 0 P. O. BOX 240868 0.43 NE + 27 92 NCI-005015/RESPONSE CHARLOTTE NC 36 LUST SUMMERFIELD S AUTO 3017 SOUTH 0.43 NE + 33 93 NCI-005261/RESPONSE CHARLOTTE NC 28209 37 STATE CHARLOTTE BATTERY 2926 YOUNGBLOOD ST 0.44 NE + 34 94 NONCD0001150/ACTIVE CHARLOTTE NC 38 LUST C.M. ALLEN CONSTUCTION 3813 SOUTH BLVD 0.45 SE + 33 95 NCI-008582/RESPONSE CHARLOTTE NC 28209 39 LUST MEJIA AUTOMOTIVE PROPERTY 3821 SOUTH BLVD 0.47 SE + 29 96 NCI-036617/ARCHIVED CHARLOTTE NC 28209 40 LUST KRISPY KREME DOUGHNUT 2901 SOUTH BLVD 0.48 NE + 28 97 NCI-027265/CLOSED OUT CHARLOTTE NC 28217 41 LUST THE APPLE BUILDING 3809 WEONA AVE 0.48 SE + 31 98 NCI-010926/RESPONSE CHARLOTTE NC 28209 42 LUST PEPSI BOTTLING COMPANY 2820 SOUTH BLVD 0.50 NE + 48 99 NCI-027982/CLOSED OUT CHARLOTTE NC 28224 42 LUST PEPSI COLA BOTTLING COMPANY 2820 SOUTH BLVD 0.50 NE + 48 100 NCI-027939/CHARLOTTE NC 28209 43 LUST ROBERT MAHONEY RESIDENCE 3326 ANSON ST 0.50 SE - 5 101 NCI-009125/CLOSED OUT CHARLOTTE NC 28209 44 STATE MITCHELLS FORMAL WEAR (AFTER HOURS 115 SCALEYBARK RD 0.53 SE + 44 102 NONCD0002084/ACTIVE CHARLOTTE NC Environmental FirstSearch Sites Summary Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0 Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No. 45 STATE NCDOT ASPHALT SITE #57 - REA CONST 2701 YOUNGBLOOD CT 0.62 NE + 29 103 NONCD0002172/ACTIVE CHARLOTTE NC 45 STATE SUTTON PARK GROCERY 2701 YOUNGBLOOD ST 0.62 NE + 29 104 NONCD0002380/ACTIVE MONROE NC 46 STATE BALDOR ELECTRIC COMPANY 3821 BARRINGER RD 0.62 SW - 20 105 NONCD0001132/ACTIVE CHARLOTTE NC 47 STATE MECKLENBURG CO. OIL SPILL BASIN CR 626 MILLER ST 0.67 NE - 17 106 NCD986189983/NFA CHARLOTTE NC 48 STATE QUALEX 2519 DISTRIBUTION ST 0.75 NE + 44 107 NONCD0002348/ACTIVE CHARLOTTE NC 49 STATE AIR LIQUIDE 2414 SOUTH BLVD 0.81 NE + 42 108 NONCD0001231/ACTIVE CHARLOTTE NC 50 STATE TACO BELL #2 2405 SOUTH BLVD 0.87 NE + 49 109 NONCD0002573/ACTIVE CHARLOTTE NC 51 STATE SOUTHSIDE INVESTMENTS LLC 2222 SOUTH BLVD 1.00 NE + 56 110 NONCD0001076/ACTIVE CHARLOTTE NC Environmental FirstSearch Sites Summary Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 TOTAL:106 GEOCODED:88 NON GEOCODED:18 SELECTED:0 Map ID DB Type Site Name/ID/Status Address Dist/Dir ElevDiff Page No. CERCLIS STEWART CREEK UNKNOWN NON GC N/A N/A NCN000410138/NOT PROPOSED CHARLOTTE NC NFRAP CSX DERAILMENT UNKNOWN NON GC N/A N/A NCN000407318/NFRAP-N CHARLOTTE NC ERNS NORTH TRYON ST NORTH TRYON ST NON GC N/A N/A NRC-971718/FIXED CHARLOTTE NC STATE UNITED METAL FINISHING RIDGE LANE RD NON GC N/A N/A NONCD0002871/ACTIVE GREEENSBORO NC SWL BICKEL DEMOLITION LANDFILL SHOPTON ROAD NON GC N/A N/A 60AD/INACTIVECLOSED CHARLOTTE NC SWL DON MISENHEIMER RUBBLE SITE ALBEMARLE RT 1 NON GC N/A N/A P0292/INACTIVECLOSED CHARLOTTE NC SWL DON R ROBERTSON DEMO LANDFILL SHOPTON ROAD NON GC N/A N/A 60C/INACTIVECLOSED CHARLOTTE NC SWL ECOSOLVE LLC PO BOX 680517 NON GC N/A N/A NCS-00801/ACTIVE CHARLOTTE NC SWL L&L ENVIRONMENTAL SERVICES PO BOX 19491 NON GC N/A N/A NCS-01094/ACTIVE CHARLOTTE NC SWL LEFLER-STUART #369 PO BOX 31547 NON GC N/A N/A NCS-00761/ACTIVE CHARLOTTE NC SWL OLD CHARLOTTE LDFL/ VANGUARD 77 CENTER NON GC N/A N/A NONCD0001065/PRE-1983 CHARLOTTE NC SWL STATESVILLE RD. LF EAST SIDE OF NORTHERLY NO NON GC N/A N/A NCD000605097/PRE-1983 CHARLOTTE NC LUST ARROWOOD ROAD EXTENSION ARROWOOD AND PARK ACCESS R NON GC N/A N/A NCI-085236/CLOSED OUT CHARLOTTE NC LUST CSX PINOCA YARD CHEMWAY AREA OF CHARLOTTE NON GC N/A N/A NCI-085419/DI CHARLOTTE NC LUST EPISCOPAL DIOCESE OF NC 0 ARROWOOD RD NON GC N/A N/A NCI-010492/CLOSED OUT CHARLOTTE NC 28217 LUST PAW CREEK - PLANTATION PIPELIN PIPELINE R-O-W WEST OF TER NON GC N/A N/A NCI-085290/RESPONSE CHARLOTTE NC BROWNFIE 330 WEST TREMONT W TREMONT AVE & SOUTH TRYO NON GC N/A N/A 14009-10-60/FINALIZED CHARLOTTE NC TRIBALLA BUREAU OF INDIAN AFFAIRS CONTACT I UNKNOWN NON GC N/A N/A BIA-28217/ NC 28217 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:48 DIST/DIR:0.08 SW ELEVATION:720 MAP ID:1 NAME:MONARCH SPRINKLER REV:6/1/12 ADDRESS:308 CLANTON RD ID1:0-014170 CHARLOTTE NC 28210 ID2:00-0-0000014170 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:NISBET OIL COMPANY PHONE: SOURCE:NCDENR Site Details Page - 1 SITE INFORMATION TOTAL NUMBER OF TANKS: 1 CONTACT INFORMATION: NISBET OIL COMPANY 1818 BAXTER STREET/PO BOX 35367 CHARLOTTE NC 28204-5367 TANK NUMBER: 1 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Gasoline, Gas Mix CAPACITY IN GALLONS: 1000 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES ARCHIVED INFORMATION AS OF 2011 TANK NUMBER: 1 INSTALLATION DATE: 19700325 CLOSED DATE: 19881001 STATUS: PERMANENTLY CLOSED CONTENTS: GASOLINE, GASOLINE MIXTURE CAPACITY IN GALLONS: 1000 COMMENTS: CONSTRUCTION MATERIAL: STEEL INTERIOR: NONE EXTERIOR: PAINT CORROSION PROTECTION: LEAK DETECTION: PIPING MATERIAL: STEEL PIPE CORROSION PROTECTION: PIPE LEAK DETECTION: OVERFLOW PROTECTION: FINANCIAL RESPONSIBILITY: CERTIFICATION TYPE: GPS SITING CONFIRMED:N PERSON CONFIRMING: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:20 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:PELTON & CRANE PLANT (FORMER)REV:6/8/12 ADDRESS:200 CLANTON RD ID1:NCD055162069 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 2 SITE INFORMATION EPA ID:NCD055162069INCIDENT ID:85670 REP DISCOVERY DATE:14-MAY-01NOTICE DATE: NEXT DUE DATE:NEXT ACTION: INCIDENT COMMENTS:INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO. UIC Permit #WI0300104 for injecting Slow Release Substrate to enhance reductive dechlorination. DATE ADDED: 2/19/1998RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MF MEDIA CONTAMINATEDCONTAMINANT TYPE SOILMETALS SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: YESREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS DOCKET NUMBER: 99188ORDER, REQUEST, AOC: AA-REC RECEIVING PARTY: SIEMENS MEDICAL SYSTEMS, INC.MEDIA COVERED: ENTIRE SITE EXECUTION DATE: 1/29/2000WITHDRAWN: NO DATE COMPLETED: NOTICE CANCELED: STAFF INITIALS: KCREC CODE: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 SPILLS SEARCH ID:31 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:CLANTON ROAD FACILITY REV:12/6/05 ADDRESS:200 CLANTON RD ID1:15846 CHARLOTTE NC ID2: MECKLENBURG STATUS:CLOSED OUT CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 3 SITE INFORMATION OWNER/OPERATOR: DATE OF RELEASE: DATE SUBMITTED: 7/16/1996 DESCRIPTION OF INCIDENT: MINOR SOIL CONTAMINATION CONFIRMED DURING REMOVAL OF USTS. CONTAMINATION INFORMATION GROUNDWATER CONTAMINATED?: N MAJOR SOIL CONTAMINATION?: Y MATERIAL INVOLVED (1): WASTE OIL AMOUNT LOST (1): AMOUNT RECOVERED (1): MATERIAL INVOLVED (2): AMOUNT LOST (2): AMOUNT RECOVERED (2): MATERIAL INVOLVED (3): AMOUNT LOST (3): AMOUNT RECOVERED (3): NUMBER OF WELLS AFFECTED: 0 NAME(S) OF CONTAMINATED WELLS: PRIORITY INFORMATION: RISK SITE?: SITE PRIORITY: PRIORITY CODE: PRIORITY UPDATE: STATUS INFORMATION: LAST MODIFIED: 8/19/1996 INCIDENT PHASE: CLOSED OUT NOV ISSUED: NORR ISSUED: 45 DAY REPORT: CORRECTIVE ACTION PLAN: CLOSURE REQ DATE: CLOSE-OUT REPORT: 7/16/1996 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 SPILLS SEARCH ID:32 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:PELTON & CRANE PLANT (FORMER,REV:12/6/05 ADDRESS:200 CLANTON RD ID1:85670 CHARLOTTE NC ID2: MECKLENBURG STATUS:NOD CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 4 SITE INFORMATION OWNER/OPERATOR: , NC DATE OF RELEASE: 5/14/2001 DATE SUBMITTED: 5/14/2001 DESCRIPTION OF INCIDENT: INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO. UIC Permit #WI0300104 for injecting Slow Release Substrate to enhance reductive dechlorin CONTAMINATION INFORMATION GROUNDWATER CONTAMINATED?: Y MAJOR SOIL CONTAMINATION?: MATERIAL INVOLVED (1): AMOUNT LOST (1): AMOUNT RECOVERED (1): MATERIAL INVOLVED (2): AMOUNT LOST (2): AMOUNT RECOVERED (2): MATERIAL INVOLVED (3): AMOUNT LOST (3): AMOUNT RECOVERED (3): NUMBER OF WELLS AFFECTED: 0 NAME(S) OF CONTAMINATED WELLS: PRIORITY INFORMATION: RISK SITE?: SITE PRIORITY: PRIORITY CODE: NOD PRIORITY UPDATE: STATUS INFORMATION: LAST MODIFIED: 4/18/2005 INCIDENT PHASE: NOD NOV ISSUED: NORR ISSUED: 45 DAY REPORT: CORRECTIVE ACTION PLAN: CLOSURE REQ DATE: CLOSE-OUT REPORT: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:45 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:CLANTON ROAD FACILITY REV:6/10/11 ADDRESS:200 CLANTON RD ID1:MO-4766 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS: CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 5 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-4766 INCIDENT NUMBER:15846 CD NUMBER:5 REEL NUMBER:0 REGIONAL CONTACT:GSB REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:BOTH REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:7/17/1996 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:4/15/1993 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:5 RESPONSIBLE OWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:45 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:CLANTON ROAD FACILITY REV:6/10/11 ADDRESS:200 CLANTON RD ID1:MO-4766 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS: CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 6 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:49 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:THE PELTON & CRANE CO.REV:6/1/12 ADDRESS:200 CLANTON RD ID1:0-014524 CHARLOTTE NC 28210 ID2:00-0-0000014524 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:THE PELTON & CRANE CO.PHONE: SOURCE:NCDENR Site Details Page - 7 - Continued on next page - SITE INFORMATION TOTAL NUMBER OF TANKS: 2 CONTACT INFORMATION: THE PELTON & CRANE CO. P.O. BOX 7800 CHARLOTTE NC 28241-7800 TANK NUMBER: 1 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Oil, New/Used/Mix CAPACITY IN GALLONS: 2000 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES TANK NUMBER: 2 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Oil, New/Used/Mix CAPACITY IN GALLONS: 650 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES REGIONAL UST DATA UST NUMBER:MO-4766 INCIDENT NUMBER:15846 CD NUMBER:5 REEL NUMBER:0 REGIONAL CONTACT:GSB REGIONAL OFFICE:MOR DATE OCCURRED: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:49 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:THE PELTON & CRANE CO.REV:6/1/12 ADDRESS:200 CLANTON RD ID1:0-014524 CHARLOTTE NC 28210 ID2:00-0-0000014524 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:THE PELTON & CRANE CO.PHONE: SOURCE:NCDENR Site Details Page - 8 - Continued on next page - RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:BOTH REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:7/17/1996 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:4/15/1993 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:5 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 COMMENTS: ARCHIVED INFORMATION AS OF 2011 TANK NUMBER: 1 INSTALLATION DATE: 19840602 CLOSED DATE: 19921001 STATUS: PERMANENTLY CLOSED CONTENTS: OIL, NEW/USED/MIXTURE Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:49 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:THE PELTON & CRANE CO.REV:6/1/12 ADDRESS:200 CLANTON RD ID1:0-014524 CHARLOTTE NC 28210 ID2:00-0-0000014524 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:THE PELTON & CRANE CO.PHONE: SOURCE:NCDENR Site Details Page - 9 CAPACITY IN GALLONS: 2000 COMMENTS: CONSTRUCTION MATERIAL: STEEL INTERIOR: UNKNOWN EXTERIOR: PAINT CORROSION PROTECTION: LEAK DETECTION: PIPING MATERIAL: STEEL PIPE CORROSION PROTECTION: PIPE LEAK DETECTION: OVERFLOW PROTECTION: FINANCIAL RESPONSIBILITY: CERTIFICATION TYPE: GPS SITING CONFIRMED:N PERSON CONFIRMING: TANK NUMBER: 2 INSTALLATION DATE: 19780604 CLOSED DATE: 19840301 STATUS: PERMANENTLY CLOSED CONTENTS: OIL, NEW/USED/MIXTURE CAPACITY IN GALLONS: 650 COMMENTS: CONSTRUCTION MATERIAL: STEEL INTERIOR: UNKNOWN EXTERIOR: PAINT CORROSION PROTECTION: LEAK DETECTION: PIPING MATERIAL: STEEL PIPE CORROSION PROTECTION: PIPE LEAK DETECTION: OVERFLOW PROTECTION: FINANCIAL RESPONSIBILITY: CERTIFICATION TYPE: GPS SITING CONFIRMED:N PERSON CONFIRMING: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:56 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:CLANTON ROAD FACILITY REV:6/1/12 ADDRESS:200 CLANTON RD ID1:NCI-015846 CHARLOTTE NC 28217 ID2:15846 MECKLENBURG STATUS:CLOSED OUT CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 10 REGIONAL UST DATA UST NUMBER:MO-4766 INCIDENT NUMBER:15846 CD NUMBER:5 REEL NUMBER:0 REGIONAL CONTACT:GSB REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:BOTH REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:7/17/1996 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:4/15/1993 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:5 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:65 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:PELTON & CRANE PLANT (FORMER)REV:10/1/01 ADDRESS:200 CLANTON RD ID1:NCI-085670 CHARLOTTE NC ID2: MECKLENBURG STATUS:NOD CONTACT: PHONE: SOURCE: Site Details Page - 11 OWNER/OPERATOR: DATE OF RELEASE: DATE SUBMITTED: 5/14/2001 DESCRIPTION OF INCIDENT: NO FILE AT MRO. INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO. CONTAMINATION INFORMATION GROUNDWATER CONTAMINATED?: Y MAJOR SOIL CONTAMINATION?: MATERIAL INVOLVED (1): AMOUNT LOST (1): AMOUNT RECOVERED (1): MATERIAL INVOLVED (2): AMOUNT LOST (2): AMOUNT RECOVERED (2): MATERIAL INVOLVED (3): AMOUNT LOST (3): AMOUNT RECOVERED (3): NUMBER OF WELLS AFFECTED: 0 NAME(S) OF CONTAMINATED WELLS: PRIORITY INFORMATION: RISK SITE?: SITE PRIORITY: 0 PRIORITY CODE: PRIORITY UPDATE: STATUS INFORMATION: LAST MODIFIED: INCIDENT PHASE: NOD NOV ISSUED: NORR ISSUED: 45 DAY REPORT: CORRECTIVE ACTION PLAN: CLOSURE REQ DATE: CLOSE-OUT REPORT: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:79 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:FORMER PELTON & CRANEPLANT REV:5/10/07 ADDRESS:200 CLANTON RD ID1:NCBR-0206-047 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE: Site Details Page - 12 SITE INFORMATION PROSPECTIVE DEVELOPER:CLANTON PARTNERS I, LLC STATUS:ACTIVE = ACTIVE ELIGBLE PROJECT DESCRIPTION:Site of a manufacturing facility specializing in equipment for the dental industry, this approximately 6-acre property has known metals, chlorinated solvent and PAH contamination in soil and groundwater. PD intends to redevelop the site into office and showroom space for non-profit involved in serving the educational, employment and enrichment needs of developmentally disabled children and adults. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:80 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:PELTON & CRANE PLANT REV:9/30/10 ADDRESS:200 CLANTON RD ID1:NCBR-1106-033 CHARLOTTE NC ID2: MECKLENBURG STATUS:FINALIZED CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 13 SITE INFORMATION PROSPECTIVE DEVELOPER:CLANTON PARTNERS I, LLC FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS DESCRIPTION:The Property (Tax Parcel Identification Number is 14702106) is located at 200 Clanton Road, Charlotte, North Carolina and comprises approximately 6 acres. The Pelton & Crane Company, a division of Siemens Medical Solutions, USA, Inc., manufactured products for the dental industry on the Brownfields Property from 1955 until 1992. Soil and groundwater at the site are impacted by chlorinated solvents. Prospective Developer has committed itself to redevelopment of the Brownfields Property for no uses other than for warehouse and, with prior written DENR approval, other commercial purposes. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:81 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:PELTON AND CRANE PLANT - FORMER REV:8/10/12 ADDRESS:200 CLANTON RD ID1:09034-05-60 CHARLOTTE NC ID2:09034-05-60 MECKLENBURG STATUS:FINALIZED CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 14 SITE INFORMATION PROJECT NUMBER:09034-05-60 For more information please contact the NCDENR at (919) 707-8383 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 VCP SEARCH ID:88 DIST/DIR:0.10 SE ELEVATION:751 MAP ID:2 NAME:PELTON & CRANE PLANT (FORMER)REV:7/30/07 ADDRESS:200 CLANTON RD ID1:VC-NCD055162069 CHARLOTTE NC ID2:NCD055162069 MECKLENBURG STATUS:VOLUNTARY CLEANUP CONTACT: PHONE: SOURCE: Site Details Page - 15 SITE INFORMATION DATE ADDED: 2/19/1998RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MF MEDIA CONTAMINATEDCONTAMINANT TYPE SOILMETALS SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: YESREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NONON HAZ SUB SITE VOL:NO NON HAZ SUB SITE NFA:NO ORDERS, AGREEMENTS, AND SOLICITATIONS DOCKET NUMBER: 99188ORDER, REQUEST, AOC: AA-REC RECEIVING PARTY: SIEMENS MEDICAL SYSTEMS, INC.MEDIA COVERED: ENTIRE SITE EXECUTION DATE: 1/29/2000WITHDRAWN: NO DATE COMPLETED: NOTICE CANCELED: STAFF INITIALS: KCREC CODE: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 SPILLS SEARCH ID:29 DIST/DIR:0.10 SW ELEVATION:724 MAP ID:3 NAME:77 CORPORATE PARK REV:6/1/12 ADDRESS:CLANTON ROAD, SOUTH TRYON STRE ID1:86378 CHARLOTTE NC 28217 ID2:MO-86378 MECKLENBURG STATUS:CURRENT RECORD CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 16 SITE INFORMATION OWNER/OPERATOR: UNKNOWN, DATE OF RELEASE: 9/10/2002 DATE SUBMITTED: 9/19/2002 DESCRIPTION OF INCIDENT: O&G CONTAM FOUND IN SOIL. MOST LIKELY SOURCE IS FORMER JUNKYARD THAT OCCUPIED A PORTION OF THE PROPERTY PRIOR TO REDEVELOPMENT THAT OCCURRED 1979-MID 80S. SITE CONTAMINATION INFORMATION GROUNDWATER CONTAMINATED?: N MAJOR SOIL CONTAMINATION?: MATERIAL INVOLVED (1): AMOUNT LOST (1): AMOUNT RECOVERED (1): MATERIAL INVOLVED (2): AMOUNT LOST (2): AMOUNT RECOVERED (2): MATERIAL INVOLVED (3): AMOUNT LOST (3): AMOUNT RECOVERED (3): NUMBER OF WELLS AFFECTED: 0 NAME(S) OF CONTAMINATED WELLS: PRIORITY INFORMATION: RISK SITE?: SITE PRIORITY: 0 PRIORITY CODE: E PRIORITY UPDATE: STATUS INFORMATION: LAST MODIFIED: 9/19/2002 INCIDENT PHASE: DI NOV ISSUED: NORR ISSUED: 45 DAY REPORT: CORRECTIVE ACTION PLAN: CLOSURE REQ DATE: CLOSE-OUT REPORT: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 SPILLS SEARCH ID:30 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4 NAME:ACOUSTICS, INC.REV:12/6/05 ADDRESS:3324 PALTON ST ID1:10174 CHARLOTTE NC ID2: MECKLENBURG STATUS:CLOSED OUT CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 17 SITE INFORMATION OWNER/OPERATOR: DATE OF RELEASE: 12/28/1992 DATE SUBMITTED: 5/14/1993 DESCRIPTION OF INCIDENT: A SMALL AMOUNT OF SOIL CONTAM. WAS DISCOVERED UPON REMOVAL OF UST. CONTAMINATION INFORMATION GROUNDWATER CONTAMINATED?: N MAJOR SOIL CONTAMINATION?: Y MATERIAL INVOLVED (1): GASOLINE AMOUNT LOST (1): AMOUNT RECOVERED (1): MATERIAL INVOLVED (2): AMOUNT LOST (2): AMOUNT RECOVERED (2): MATERIAL INVOLVED (3): AMOUNT LOST (3): AMOUNT RECOVERED (3): NUMBER OF WELLS AFFECTED: 0 NAME(S) OF CONTAMINATED WELLS: PRIORITY INFORMATION: RISK SITE?: SITE PRIORITY: PRIORITY CODE: PRIORITY UPDATE: STATUS INFORMATION: LAST MODIFIED: 2/19/1997 INCIDENT PHASE: CLOSED OUT NOV ISSUED: NORR ISSUED: 45 DAY REPORT: CORRECTIVE ACTION PLAN: CLOSURE REQ DATE: CLOSE-OUT REPORT: 5/13/1997 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:35 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4 NAME:ACOUSTICS INCORPORATED REV:6/1/12 ADDRESS:3324 PELTON ST ID1:0-026559 CHARLOTTE NC 28217 ID2:00-0-0000026559 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:ACOUSTICS INCORPORATED PHONE: SOURCE:NCDENR Site Details Page - 18 - Continued on next page - SITE INFORMATION TOTAL NUMBER OF TANKS: 1 CONTACT INFORMATION: ACOUSTICS INCORPORATED 3324 PELTON STREET CHARLOTTE NC 28217 TANK NUMBER: 1 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Gasoline, Gas Mix CAPACITY IN GALLONS: 2000 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:1 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES REGIONAL UST DATA UST NUMBER:MO-3782 INCIDENT NUMBER:10174 CD NUMBER:3 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED:12/28/1992 RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:35 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4 NAME:ACOUSTICS INCORPORATED REV:6/1/12 ADDRESS:3324 PELTON ST ID1:0-026559 CHARLOTTE NC 28217 ID2:00-0-0000026559 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:ACOUSTICS INCORPORATED PHONE: SOURCE:NCDENR Site Details Page - 19 - Continued on next page - RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:5/13/1993 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:12/28/1992 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:3 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 COMMENTS: ARCHIVED INFORMATION AS OF 2011 TANK NUMBER: 1 INSTALLATION DATE: 19640927 CLOSED DATE: 19921231 STATUS: PERMANENTLY CLOSED CONTENTS: GASOLINE, GASOLINE MIXTURE CAPACITY IN GALLONS: 2000 COMMENTS: CONSTRUCTION MATERIAL: STEEL INTERIOR: UNKNOWN EXTERIOR: UNKNOWN CORROSION PROTECTION: LEAK DETECTION: PIPING MATERIAL: UNKNOWN PIPE CORROSION PROTECTION: PIPE LEAK DETECTION: OVERFLOW PROTECTION: FINANCIAL RESPONSIBILITY: CERTIFICATION TYPE: GPS SITING CONFIRMED:N Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:35 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4 NAME:ACOUSTICS INCORPORATED REV:6/1/12 ADDRESS:3324 PELTON ST ID1:0-026559 CHARLOTTE NC 28217 ID2:00-0-0000026559 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:ACOUSTICS INCORPORATED PHONE: SOURCE:NCDENR Site Details Page - 20 PERSON CONFIRMING: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:36 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4 NAME:ACOUSTICS, INC.REV:6/10/11 ADDRESS:3324 PELTON ST ID1:MO-3782 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS: CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 21 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-3782 INCIDENT NUMBER:10174 CD NUMBER:3 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED:12/28/1992 RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:5/13/1993 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:12/28/1992 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:3 RESPONSIBLE OWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:36 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4 NAME:ACOUSTICS, INC.REV:6/10/11 ADDRESS:3324 PELTON ST ID1:MO-3782 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS: CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 22 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:50 DIST/DIR:0.11 SE ELEVATION:758 MAP ID:4 NAME:ACOUSTICS, INC.REV:6/1/12 ADDRESS:3324 PALTON ST ID1:NCI-010174 CHARLOTTE NC 28217 ID2:10174 MECKLENBURG STATUS:CLOSED OUT CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 23 REGIONAL UST DATA UST NUMBER:MO-3782 INCIDENT NUMBER:10174 CD NUMBER:3 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED:12/28/1992 RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:5/13/1993 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:12/28/1992 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:3 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:43 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5 NAME:CATS BUS M AND O REV:6/1/12 ADDRESS:3251 S TRYON ST ID1:0-03679 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:DOUG PIEROTTI PHONE:7044325212 SOURCE:NCDENR Site Details Page - 24 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-8160 INCIDENT NUMBER:36749 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:DPB REGIONAL OFFICE:MOR DATE OCCURRED:12/23/2009 RESPONSIBLE COMPANY: CITY OF CHARLOTTE 600 EAST FOURTH STREET CHARLOTTE ,NC , 282022844 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED:1 SITE PRIORITY: RISK:U RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:RESIDENTIAL CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:12/23/2009 CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:0 RESPONSIBLE OWNER:-1 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:43 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5 NAME:CATS BUS M AND O REV:6/1/12 ADDRESS:3251 S TRYON ST ID1:0-03679 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:DOUG PIEROTTI PHONE:7044325212 SOURCE:NCDENR Site Details Page - 25 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 COMMENTS:tank pump controller malfunction, which resulted in inadvertently overfilling UST-3. Release then resulting from damaged spill bucket. Product migrated from stone backfill in the tankpit to a crack in the storm drain, which lead to an outfall, which lead to a drainage ditch, to a tributary of Irwin Creek. Surface water notified. As of 1-20-2010, several AFVR events have been conducted on an installed six inch recovery well, to dewater (water source unknown at this time) and to remove product from the pit as an emergency measure. Also storm water pipe has been and currently been through several repairs. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:44 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5 NAME:CATS BUS MAINTENANCE AND OPS FAC REV:6/1/12 ADDRESS:3251 S TRYON ST ID1:0-036729 CHARLOTTE NC 28217 ID2:00-0-0000036729 MECKLENBURG STATUS:CURRENTLY OPERATIONAL CONTACT:CHARLOTTE AREA TRANSIT SYSTEM PHONE: SOURCE:NCDENR Site Details Page - 26 - Continued on next page - SITE INFORMATION TOTAL NUMBER OF TANKS: 4 CONTACT INFORMATION: CHARLOTTE AREA TRANSIT SYSTEM 600 E. 4TH ST./DAVID WOLFE-E&PM CHARLOTTE NC 28202-2844 TANK NUMBER: 1 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Diesel CAPACITY IN GALLONS: 40000 TANK CONSTRUCTION:5 PIPE CONSTRUCTION:6 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK:NO COMMERCIAL TANK:YES REGULATED TANK:YES TANK NUMBER: 2 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Diesel CAPACITY IN GALLONS: 40000 TANK CONSTRUCTION:5 PIPE CONSTRUCTION:6 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK:NO COMMERCIAL TANK:YES REGULATED TANK:YES TANK NUMBER: 3 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Diesel CAPACITY IN GALLONS: 40000 TANK CONSTRUCTION:5 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:44 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5 NAME:CATS BUS MAINTENANCE AND OPS FAC REV:6/1/12 ADDRESS:3251 S TRYON ST ID1:0-036729 CHARLOTTE NC 28217 ID2:00-0-0000036729 MECKLENBURG STATUS:CURRENTLY OPERATIONAL CONTACT:CHARLOTTE AREA TRANSIT SYSTEM PHONE: SOURCE:NCDENR Site Details Page - 27 - Continued on next page - PIPE CONSTRUCTION:6 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK:NO COMMERCIAL TANK:YES REGULATED TANK:YES TANK NUMBER: 4 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Diesel CAPACITY IN GALLONS: 10000 TANK CONSTRUCTION:5 PIPE CONSTRUCTION:6 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK:NO COMMERCIAL TANK:YES REGULATED TANK:YES ARCHIVED INFORMATION AS OF 2011 TANK NUMBER: 1 INSTALLATION DATE: 20040430 CLOSED DATE: STATUS: CURRENTLY OPERATIONAL CONTENTS: DIESEL, DIESEL MIXTURE CAPACITY IN GALLONS: 40000 COMMENTS: CONSTRUCTION MATERIAL: FIBERGLASS REINFORCED PLASTIC INTERIOR: DOUBLE WALL EXTERIOR: FRP CORROSION PROTECTION: FRP TANK/PIPING LEAK DETECTION: AUTOMATIC TANK GAUGING PIPING MATERIAL: DOUBLE WALL PIPE CORROSION PROTECTION: FRP TANK/PIPING PIPE LEAK DETECTION: AUTOMATIC LINE LEAK DETECTORS OVERFLOW PROTECTION: CATCHMENT BASIN FINANCIAL RESPONSIBILITY: FINANCIAL TEST OF SELF INSURANCE CERTIFICATION TYPE: INSTALLER CERTIFIED BY TANK AND PIPING MANUFACTURERS GPS SITING CONFIRMED: PERSON CONFIRMING: TANK NUMBER: 2 INSTALLATION DATE: 20040430 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:44 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5 NAME:CATS BUS MAINTENANCE AND OPS FAC REV:6/1/12 ADDRESS:3251 S TRYON ST ID1:0-036729 CHARLOTTE NC 28217 ID2:00-0-0000036729 MECKLENBURG STATUS:CURRENTLY OPERATIONAL CONTACT:CHARLOTTE AREA TRANSIT SYSTEM PHONE: SOURCE:NCDENR Site Details Page - 28 - More Details Exist For This Site; Max Page Limit Reached - CLOSED DATE: STATUS: CURRENTLY OPERATIONAL CONTENTS: DIESEL, DIESEL MIXTURE CAPACITY IN GALLONS: 40000 COMMENTS: CONSTRUCTION MATERIAL: FIBERGLASS REINFORCED PLASTIC INTERIOR: DOUBLE WALL EXTERIOR: FRP CORROSION PROTECTION: FRP TANK/PIPING LEAK DETECTION: AUTOMATIC TANK GAUGING PIPING MATERIAL: DOUBLE WALL PIPE CORROSION PROTECTION: FRP TANK/PIPING PIPE LEAK DETECTION: AUTOMATIC LINE LEAK DETECTORS OVERFLOW PROTECTION: CATCHMENT BASIN FINANCIAL RESPONSIBILITY: FINANCIAL TEST OF SELF INSURANCE CERTIFICATION TYPE: INSTALLER CERTIFIED BY TANK AND PIPING MANUFACTURERS GPS SITING CONFIRMED: PERSON CONFIRMING: TANK NUMBER: 3 INSTALLATION DATE: 20040430 CLOSED DATE: STATUS: CURRENTLY OPERATIONAL CONTENTS: DIESEL, DIESEL MIXTURE CAPACITY IN GALLONS: 40000 COMMENTS: CONSTRUCTION MATERIAL: FIBERGLASS REINFORCED PLASTIC INTERIOR: DOUBLE WALL EXTERIOR: FRP CORROSION PROTECTION: FRP TANK/PIPING LEAK DETECTION: AUTOMATIC TANK GAUGING PIPING MATERIAL: DOUBLE WALL PIPE CORROSION PROTECTION: FRP TANK/PIPING PIPE LEAK DETECTION: AUTOMATIC LINE LEAK DETECTORS OVERFLOW PROTECTION: CATCHMENT BASIN FINANCIAL RESPONSIBILITY: FINANCIAL TEST OF SELF INSURANCE CERTIFICATION TYPE: INSTALLER CERTIFIED BY TANK AND PIPING MANUFACTURERS GPS SITING CONFIRMED: PERSON CONFIRMING: TANK NUMBER: 4 INSTALLATION DATE: 20040430 CLOSED DATE: STATUS: CURRENTLY OPERATIONAL CONTENTS: DIESEL, DIESEL MIXTURE CAPACITY IN GALLONS: 10000 COMMENTS: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:54 DIST/DIR:0.12 NE ELEVATION:724 MAP ID:5 NAME:CATS BUS M AND O REV:6/1/12 ADDRESS:3251 S TRYON ST ID1:NCI-036749 CHARLOTTE NC 28217 ID2:36749 MECKLENBURG STATUS:CURRENT RECORD CONTACT:DOUG PIEROTTI PHONE:7044325212 SOURCE:NCDENR Site Details Page - 29 REGIONAL UST DATA UST NUMBER:MO-8160 INCIDENT NUMBER:36749 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:DPB REGIONAL OFFICE:MOR DATE OCCURRED:12/23/2009 RESPONSIBLE COMPANY: CITY OF CHARLOTTE 600 EAST FOURTH STREET CHARLOTTE ,NC , 282022844 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED:1 SITE PRIORITY: RISK:U RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:RESIDENTIAL CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:12/23/2009 CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:0 RESPONSIBLE OWNER:-1 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:47 DIST/DIR:0.13 SW ELEVATION:730 MAP ID:6 NAME:JOE B. WILLIAMS PROPERTY REV:6/1/12 ADDRESS:3500 S TRYON ST ID1:MO-4083 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:MR. JOE WILLIAMS PHONE:803-831-1822 SOURCE:NCDENR Site Details Page - 30 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-4083 INCIDENT NUMBER:12153 CD NUMBER:211 REEL NUMBER:0 REGIONAL CONTACT:CBC REGIONAL OFFICE:MOR DATE OCCURRED:5/2/1994 RESPONSIBLE COMPANY: 6121 CHARLOTTE HIGHWAY YORK ,SC , 29745 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT:5/17/1994 VIOLATION: PHASE REQUIRED:2 SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:RESIDENTIAL CLOSED REVIEW REQUESTED: CASE CLOSED:6/3/2004 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:4/5/2004 CLEAN UP:5/2/1994 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:211 RESPONSIBLE OWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:47 DIST/DIR:0.13 SW ELEVATION:730 MAP ID:6 NAME:JOE B. WILLIAMS PROPERTY REV:6/1/12 ADDRESS:3500 S TRYON ST ID1:MO-4083 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:MR. JOE WILLIAMS PHONE:803-831-1822 SOURCE:NCDENR Site Details Page - 31 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 COMMENTS:Removal of five 4,000-gallon gasoline and one 4,000-gallon diesel tanks in 1993. Closure sampling indicated TPH as high as 14,000. LSA indicates no soil > residential. Groundwater exceeds 2L. Low risk. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:61 DIST/DIR:0.13 SW ELEVATION:730 MAP ID:6 NAME:JOE B. WILLIAMS PROPERTY REV:6/1/12 ADDRESS:3500 S STRYON ST ID1:NCI-012153 CHARLOTTE NC 28217 ID2:12153 MECKLENBURG STATUS:CLOSED OUT CONTACT:MR. JOE WILLIAMS PHONE:803-831-1822 SOURCE:NCDENR Site Details Page - 32 REGIONAL UST DATA UST NUMBER:MO-4083 INCIDENT NUMBER:12153 CD NUMBER:211 REEL NUMBER:0 REGIONAL CONTACT:CBC REGIONAL OFFICE:MOR DATE OCCURRED:5/2/1994 RESPONSIBLE COMPANY: 6121 CHARLOTTE HIGHWAY YORK ,SC , 29745 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT:5/17/1994 VIOLATION: PHASE REQUIRED:2 SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:RESIDENTIAL CLOSED REVIEW REQUESTED: CASE CLOSED:6/3/2004 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:4/5/2004 CLEAN UP:5/2/1994 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:211 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:34 DIST/DIR:0.13 NE ELEVATION:702 MAP ID:7 NAME:3206 SOUTH TRYON REV:6/1/12 ADDRESS:3206 S TRYON ST ID1:MO-2336 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:HADI GHRAIRI PHONE: SOURCE:NCDENR Site Details Page - 33 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-2336 INCIDENT NUMBER: CD NUMBER:59 REEL NUMBER:0 REGIONAL CONTACT:ARL REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: JANEEN INVESTMENT 3030 S TRYON STREET CHARLOTTE ,NC , 28217 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK: RISK OF INCIDENT: INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED:1/8/2001 CASE CLOSED:1/10/2001 CONTAMINATION:NONE SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP: CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:59 RESPONSIBLE OWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:34 DIST/DIR:0.13 NE ELEVATION:702 MAP ID:7 NAME:3206 SOUTH TRYON REV:6/1/12 ADDRESS:3206 S TRYON ST ID1:MO-2336 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:HADI GHRAIRI PHONE: SOURCE:NCDENR Site Details Page - 34 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 COMMENTS: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 RCRAGN SEARCH ID:5 DIST/DIR:0.18 SE ELEVATION:767 MAP ID:8 NAME:ALTEC INDUSTRIES, INC REV:9/14/10 ADDRESS:3335 PELTON ST ID1:NCD986232510 CHALOTTE NC 28220 ID2: MECKLENBURG STATUS:SGN CONTACT: PHONE: SOURCE:EPA Site Details Page - 35 CONTACT INFORMATION: RYAN MCKINNEY 7045250059 RYAN.MCKINNEY@ALTEC.COM UNIVERSE INFORMATION: GOVERNMENT PERFORMANCE AND RESULTS ACT (GPRA) GPRA CA BASELINE UNIVERSE:NO GPRA CA 2008:NO SUBJECT TO CORRECTIVE ACTION (SUBJCA) SUBJCA:NO SUBJCA TSD 3004:NO SUBJCA NON TSD:NO SUBJCA TSD DISCRETION:NO PERMIT WORKLOAD:----- CLOSURE WORKLOAD:----- POST CLOSURE WORKLOAD:----- PERMITTING /CLOSURE/POST-CLOSURE PROGRESS:----- CORRECTIVE ACTION WORKLOAD:NO GENERATOR STATUS:SQG TRANSPORTER:NO UNIVERSAL WASTE:NO RECYCLER:NO USED OIL:NO IMPORTER:NO MIXED WASTE GENERATOR:NO ONSITE BURNER EXEMPT:NO FURNACE EXEMPTION:NO UNDERGROUND INJECTION:NO NAIC 1:Motor Vehicle Body Manufacturing NAIC 2: NAIC 3: NAIC 4: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:38 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9 NAME:BARCLAYS CAPITAL REV:12/21/10 ADDRESS:3417 TRADE PARK CT ID1:MO-180 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS: CONTACT:B.J. EADS PHONE:704-529-1766 SOURCE:NCDENR Site Details Page - 36 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-180 INCIDENT NUMBER: CD NUMBER:60 REEL NUMBER:0 REGIONAL CONTACT:ARL REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: BARCLAYS CAPITAL 3417 TRADE PARK COURT CHARLOTTE ,NC , 28217 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK: RISK OF INCIDENT: INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED:1/25/2000 CASE CLOSED:1/26/2000 CONTAMINATION:NONE SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP: CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:60 RESPONSIBLE OWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:38 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9 NAME:BARCLAYS CAPITAL REV:12/21/10 ADDRESS:3417 TRADE PARK CT ID1:MO-180 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS: CONTACT:B.J. EADS PHONE:704-529-1766 SOURCE:NCDENR Site Details Page - 37 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:39 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9 NAME:BARCLAYS CAPITAL REV:6/1/12 ADDRESS:3417 TRADE PARK CT ID1:MO-0180 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:B.J. EADS PHONE:704-529-1766 SOURCE:NCDENR Site Details Page - 38 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-0180 INCIDENT NUMBER: CD NUMBER:60 REEL NUMBER:0 REGIONAL CONTACT:ARL REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: BARCLAYS CAPITAL 3417 TRADE PARK COURT CHARLOTTE ,NC , 28217 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK: RISK OF INCIDENT: INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED:1/25/2000 CASE CLOSED:1/26/2000 CONTAMINATION:NONE SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP: CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:60 RESPONSIBLE OWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:39 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9 NAME:BARCLAYS CAPITAL REV:6/1/12 ADDRESS:3417 TRADE PARK CT ID1:MO-0180 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:B.J. EADS PHONE:704-529-1766 SOURCE:NCDENR Site Details Page - 39 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 COMMENTS: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:40 DIST/DIR:0.18 NW ELEVATION:716 MAP ID:9 NAME:BARCLAYS CAPITAL, INC.REV:6/1/12 ADDRESS:3417 TRADE PARK CT ID1:0-035914 CHARLOTTE NC 28217 ID2:00-0-0000035914 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:BARCLAYS CAPITAL, INC.PHONE: SOURCE:NCDENR Site Details Page - 40 SITE INFORMATION TOTAL NUMBER OF TANKS: 1 CONTACT INFORMATION: BARCLAYS CAPITAL, INC. 3417 TRADE PARK CT ATTN:K NEWTON CHARLOTTE NC 28217 TANK NUMBER: 1 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Diesel CAPACITY IN GALLONS: 8000 TANK CONSTRUCTION:2 PIPE CONSTRUCTION:3 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES ARCHIVED INFORMATION AS OF 2011 TANK NUMBER: 1 INSTALLATION DATE: 19890101 CLOSED DATE: 19991228 STATUS: PERMANENTLY CLOSED CONTENTS: DIESEL, DIESEL MIXTURE CAPACITY IN GALLONS: 8000 COMMENTS: CONSTRUCTION MATERIAL: FIBERGLASS REINFORCED PLASTIC INTERIOR: FRP EXTERIOR: FRP CORROSION PROTECTION: FRP TANK/PIPING LEAK DETECTION: PIPING MATERIAL: FRP PIPE CORROSION PROTECTION: FRP TANK/PIPING PIPE LEAK DETECTION: MANUAL TANK GAUGING OVERFLOW PROTECTION: CATCHMENT BASIN FINANCIAL RESPONSIBILITY: CERTIFICATION TYPE: INSTALLER CERTIFIED BY TANK AND PIPING MANUFACTURERS GPS SITING CONFIRMED:N PERSON CONFIRMING: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 RCRAGN SEARCH ID:7 DIST/DIR:0.19 NE ELEVATION:717 MAP ID:10 NAME:CATS-BOD S TRYON BUS GARAGE REV:9/11/12 ADDRESS:3145 S TRYON ST ID1:NC0991302662 CHARLOTTE NC 28202 ID2: MECKLENBURG STATUS:VGN CONTACT: PHONE: SOURCE:EPA Site Details Page - 41 - Continued on next page - SITE INFORMATION CONTACT INFORMATION: JAY C FAGEL S TRYON ST CHARLOTTE NC 28217 PHONE: 704-336-4082 OWNER NAME:CHARLOTTE AREA TRANSIT SYSTEMS OWNER TYPE:F-FEDERAL OPERATOR:CHARLOTTE AREA TRANSIT SYSTEMS OPERATOR_TYPE:F-FEDERAL MAILING ADDRESS:3145 S TRYON ST UNIVERSE INFORMATION: RECEIVED DATE:06/28/2012 SUBJECT TO CORRECTIVE ACTION (SUBJCA) SUBJCA:N - NO SUBJCA TSD 3004:N - NO SUBJCA NON TSD:N - NO SIGNIFICANT NON-COMPLIANCE(SNC):N - NO BEGINNING OF THE YEAR SNC: PERMIT WORKLOAD:----- CLOSURE WORKLOAD:----- POST CLOSURE WORKLOAD:----- PERMITTING /CLOSURE/POST-CLOSURE PROGRESS:----- CORRECTIVE ACTION WORKLOAD:N - NO GENERATOR STATUS:CEG - CONDITIONALLY EXEMPT SMALL QUANTITY GENERATORS: GENERATES LESS THAN 100 KG/MONTH OF HAZARDOUS WASTE INSTITUTIONAL CONTROL:N-NOENGINEERING CONTROL:N HUMAN EXPOSURE:N-NOGW CONTROLS:N- NO LAND TYPE:P-PRIVATESHORT TERM GEN:N TRANS FACILITY:NREC WASTE FROM OFF SITE:N IMPORTER ACTIVITY:N - NOMIXED WASTE GEN:N - NO TRANS ACTIVITY:N - NOTSD ACTIVITY:N - NO RECYCLER ACTIVITY:N - NOONSITE BURNER EXEMPT:N - NO FURNACE EXEMPTION:N - NOUNDER INJECT ACTIVITY:N - NO REC WASTE FROM OFF SITE:N - NOUNIV WASTE DEST FAC:N USED OIL TRANS:N - NOUSED OIL PROCESSOR:N - NO USED OIL REFINER:N - NOUSED OIL FUEL BURNER:N - NO UO FUEL MARKETER TO BURNER:NUSED OIL SPEC MARKETER:N - NO NAIC INFORMATION 485113 - BUS AND OTHER MOTOR VEHICLE TRANSIT SYSTEMS 485112 - COMMUTER RAIL SYSTEMS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 RCRAGN SEARCH ID:7 DIST/DIR:0.19 NE ELEVATION:717 MAP ID:10 NAME:CATS-BOD S TRYON BUS GARAGE REV:9/11/12 ADDRESS:3145 S TRYON ST ID1:NC0991302662 CHARLOTTE NC 28202 ID2: MECKLENBURG STATUS:VGN CONTACT: PHONE: SOURCE:EPA Site Details Page - 42 ENFORCEMENT INFORMATION: VIOLATION INFORMATION: VIOLATION NUMBER: 1RESPONSIBLE: S - STATE DETERMINED: 10/17/2010DETERMINED BY: S - STATE CITATION: RESOLVED: 11/25/2011 TYPE: FEDERAL OR STATE STATUTE HAZARDOUS WASTE INFORMATION: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 RCRAGN SEARCH ID:8 DIST/DIR:0.19 SW ELEVATION:727 MAP ID:11 NAME:PROVIDENCE PAINT CO REV:9/11/12 ADDRESS:428 BLAIRHILL RD ID1:NCR000143172 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:SGN CONTACT: PHONE: SOURCE:EPA Site Details Page - 43 - Continued on next page - SITE INFORMATION CONTACT INFORMATION: DENNIS KRESSNER BLAIRHILL RD CHARLOTTE NC 28217 PHONE: 7045211250 OWNER NAME:JERRY KRESSNER OWNER TYPE:P-PRIVATE OPERATOR:JERRY KRESSNER OPERATOR_TYPE:P-PRIVATE MAILING ADDRESS: PO BOX 11965 CHARLOTTE, NC 28220-1965 UNIVERSE INFORMATION: RECEIVED DATE:08/10/2012 SUBJECT TO CORRECTIVE ACTION (SUBJCA) SUBJCA:N - NO SUBJCA TSD 3004:N - NO SUBJCA NON TSD:N - NO SIGNIFICANT NON-COMPLIANCE(SNC):N - NO BEGINNING OF THE YEAR SNC: PERMIT WORKLOAD:----- CLOSURE WORKLOAD:----- POST CLOSURE WORKLOAD:----- PERMITTING /CLOSURE/POST-CLOSURE PROGRESS:----- CORRECTIVE ACTION WORKLOAD:N - NO GENERATOR STATUS:SQG - SMALL QUANTITY GENERATOR: GENERATES 100 - 1000 KG/MONTH OF HAZARDOUS WASTE INSTITUTIONAL CONTROL:N-NOENGINEERING CONTROL:N HUMAN EXPOSURE:N-NOGW CONTROLS:N- NO LAND TYPE:P-PRIVATESHORT TERM GEN:N TRANS FACILITY:NREC WASTE FROM OFF SITE:N IMPORTER ACTIVITY:N - NOMIXED WASTE GEN:N - NO TRANS ACTIVITY:N - NOTSD ACTIVITY:N - NO RECYCLER ACTIVITY:N - NOONSITE BURNER EXEMPT:N - NO FURNACE EXEMPTION:N - NOUNDER INJECT ACTIVITY:N - NO REC WASTE FROM OFF SITE:N - NOUNIV WASTE DEST FAC:N USED OIL TRANS:N - NOUSED OIL PROCESSOR:N - NO USED OIL REFINER:N - NOUSED OIL FUEL BURNER:N - NO UO FUEL MARKETER TO BURNER:NUSED OIL SPEC MARKETER:N - NO NAIC INFORMATION 44412 - PAINT AND WALLPAPER STORES Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 RCRAGN SEARCH ID:8 DIST/DIR:0.19 SW ELEVATION:727 MAP ID:11 NAME:PROVIDENCE PAINT CO REV:9/11/12 ADDRESS:428 BLAIRHILL RD ID1:NCR000143172 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:SGN CONTACT: PHONE: SOURCE:EPA Site Details Page - 44 ENFORCEMENT INFORMATION: VIOLATION INFORMATION: HAZARDOUS WASTE INFORMATION: D001 - Ignitable waste D035 - Methyl ethyl ketone F003 - The following spent non-halogenated solvents: Xylene, acetone, ethyl acetate, ethyl benzene, ethyl ether, methyl isobutyl ketone, n-butyl alcohol, cyclohexanone, and methanol; all spent solvent mixtures/ blends containing, before use, only the above spent non- halogenated solvents; and all spent solvent mixtures/blends containing, before use, one or more of the above non-halogenated solvents, and a total of ten percent or more (by volume) of one or more of those solvents listed in F001, F002, F004, and F005; and still bottoms from the recovery of these spent solvents and spent solvent mixtures. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 RCRAGN SEARCH ID:9 DIST/DIR:0.20 SW ELEVATION:727 MAP ID:12 NAME:PURE CLEAN REV:9/14/10 ADDRESS:3601 S TRYON ST ID1:NCD982163180 CHARLOTTE NC 28205 ID2: MECKLENBURG STATUS:SGN CONTACT: PHONE: SOURCE:EPA Site Details Page - 45 SITE INFORMATION CONTACT INFORMATION: WILLIAM CARSTENS 3601 S TRYON ST CHARLOTTE NC 28217 PHONE: 7045250244 UNIVERSE INFORMATION: NAIC INFORMATION ENFORCEMENT INFORMATION: AGENCY: S - STATEDATE: 11/23/1994 TYPE: 120 - WRITTEN INFORMAL AGENCY: S - STATEDATE: 11/23/1994 TYPE: 120 - WRITTEN INFORMAL VIOLATION INFORMATION: VIOLATION NUMBER: 0001RESPONSIBLE: S - STATE DETERMINED: 11/23/1994DETERMINED BY: S - STATE CITATION: 130A-294-1 RESOLVED: 12/13/1994 TYPE: GENERATOR-GENERAL REQUIREMENTS HAZARDOUS WASTE INFORMATION: The following spent halogenated solvents: Tetrachloroethylene, methylene chloride, trichloroethylene, 1,1,1-trichloroethane, chlorobenzene, 1,1,2- trichloro-1,2,2-trifluoroethane, ortho-dichlorobenzene, trichlorofluoromethane Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:11 DIST/DIR:0.20 SW ELEVATION:726 MAP ID:13 NAME:AMERICAN FENCE SOLVENTS REV:6/8/12 ADDRESS:3605 S TRYON ST ID1:NONCD0001255 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 46 SITE INFORMATION EPA ID:NONCD0001255INCIDENT ID:85958 REP DISCOVERY DATE:23-OCT-01NOTICE DATE: NEXT DUE DATE:NEXT ACTION:REVU REPORT INCIDENT COMMENTS:LOW LEVEL SOLVENTS (UP TO 10 PPB PCE) DETECTED IN MWS DURING PHASE II. OFFSITE SOURCE POSSIBLE. ALSO ASTS & FORMER UST ON SITE AND NEXT DOOR (UST#6923), ANY OF WHICH MAY BE SOURCE OF PETROLEUM (UST SECTION LEAD ON PETROLEUM ISSUE). DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:37 DIST/DIR:0.20 SW ELEVATION:726 MAP ID:13 NAME:AMERICAN FENCE REV:6/1/12 ADDRESS:3605 S TRYON ST ID1:MO-7007 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:JAMES C. PRESSON PHONE:7045628101 SOURCE:NCDENR Site Details Page - 47 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-7007 INCIDENT NUMBER:27713 CD NUMBER:210 REEL NUMBER:0 REGIONAL CONTACT:CBC REGIONAL OFFICE:MOR DATE OCCURRED:7/11/2001 RESPONSIBLE COMPANY: AMERICAN FENCE SUPPLY COMPANY POST OFFICE BOX 241251 CHARLOTTE ,NC , 28224 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED:1 SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:SOIL TO GROUNDWATER CLOSED REVIEW REQUESTED: CASE CLOSED:8/10/2004 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:YES LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:8/27/2004 CLEAN UP:1/1/1986 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:210 RESPONSIBLE OWNER:-1 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:37 DIST/DIR:0.20 SW ELEVATION:726 MAP ID:13 NAME:AMERICAN FENCE REV:6/1/12 ADDRESS:3605 S TRYON ST ID1:MO-7007 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:JAMES C. PRESSON PHONE:7045628101 SOURCE:NCDENR Site Details Page - 48 RESPONSIBLE OPERATOR:-1 RESPONSIBLE LANDOWNER:-1 COMMENTS:One 1,000-gallon gasoline UST removed in 1986. ESA (2001) sampling indicates minor soil contamination and 2L exceedances. LSA submitted using ESA data. No additional soil collection. MW-2 qualifies for LSA well. Soil analytical during ESA not complete for UST closure. WSW survey letters not completed. WSW survey and soil boring completed. NRP for groundwater to close. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:51 DIST/DIR:0.20 SW ELEVATION:726 MAP ID:13 NAME:AMERICAN FENCE REV:6/1/12 ADDRESS:3605 S TRYON ST ID1:NCI-027713 CHARLOTTE NC 28217 ID2:27713 MECKLENBURG STATUS:CLOSED OUT CONTACT:JAMES C. PRESSON PHONE:7045628101 SOURCE:NCDENR Site Details Page - 49 REGIONAL UST DATA UST NUMBER:MO-7007 INCIDENT NUMBER:27713 CD NUMBER:210 REEL NUMBER:0 REGIONAL CONTACT:CBC REGIONAL OFFICE:MOR DATE OCCURRED:7/11/2001 RESPONSIBLE COMPANY: AMERICAN FENCE SUPPLY COMPANY POST OFFICE BOX 241251 CHARLOTTE ,NC , 28224 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED:1 SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:SOIL TO GROUNDWATER CLOSED REVIEW REQUESTED: CASE CLOSED:8/10/2004 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:YES LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:8/27/2004 CLEAN UP:1/1/1986 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:210 RESPONSIBLE OWNER:-1 RESPONSIBLE OPERATOR:-1 RESPONSIBLE LANDOWNER:-1 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 RCRAGN SEARCH ID:6 DIST/DIR:0.21 NW ELEVATION:682 MAP ID:14 NAME:ARTS ENGRAVING CO INC REV:9/11/12 ADDRESS:3136 MAY ST ID1:NCD003151701 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:VGN CONTACT: PHONE: SOURCE:EPA Site Details Page - 50 - Continued on next page - SITE INFORMATION CONTACT INFORMATION: WAYDE CLARK 3136 MAY ST CHARLOTTE NC 28217 PHONE: 7045235115 OWNER NAME:WILLIAM L PLEMMONS OWNER TYPE:P-PRIVATE OPERATOR: OPERATOR_TYPE: MAILING ADDRESS: PO BOX 32023 CHARLOTTE, NC 28232 UNIVERSE INFORMATION: RECEIVED DATE:12/18/1997 SUBJECT TO CORRECTIVE ACTION (SUBJCA) SUBJCA:N - NO SUBJCA TSD 3004:N - NO SUBJCA NON TSD:N - NO SIGNIFICANT NON-COMPLIANCE(SNC):N - NO BEGINNING OF THE YEAR SNC: PERMIT WORKLOAD:----- CLOSURE WORKLOAD:----- POST CLOSURE WORKLOAD:----- PERMITTING /CLOSURE/POST-CLOSURE PROGRESS:----- CORRECTIVE ACTION WORKLOAD:N - NO GENERATOR STATUS:CEG - CONDITIONALLY EXEMPT SMALL QUANTITY GENERATORS: GENERATES LESS THAN 100 KG/MONTH OF HAZARDOUS WASTE INSTITUTIONAL CONTROL:N-NOENGINEERING CONTROL:N HUMAN EXPOSURE:N-NOGW CONTROLS:N- NO LAND TYPE:P-PRIVATESHORT TERM GEN:N TRANS FACILITY:NREC WASTE FROM OFF SITE:N IMPORTER ACTIVITY:N - NOMIXED WASTE GEN:N - NO TRANS ACTIVITY:N - NOTSD ACTIVITY:N - NO RECYCLER ACTIVITY:N - NOONSITE BURNER EXEMPT:N - NO FURNACE EXEMPTION:N - NOUNDER INJECT ACTIVITY:N - NO REC WASTE FROM OFF SITE:N - NOUNIV WASTE DEST FAC:N USED OIL TRANS:N - NOUSED OIL PROCESSOR:N - NO USED OIL REFINER:N - NOUSED OIL FUEL BURNER:N - NO UO FUEL MARKETER TO BURNER:NUSED OIL SPEC MARKETER:N - NO NAIC INFORMATION Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 RCRAGN SEARCH ID:6 DIST/DIR:0.21 NW ELEVATION:682 MAP ID:14 NAME:ARTS ENGRAVING CO INC REV:9/11/12 ADDRESS:3136 MAY ST ID1:NCD003151701 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:VGN CONTACT: PHONE: SOURCE:EPA Site Details Page - 51 ENFORCEMENT INFORMATION: AGENCY: STATEDATE: 97/13/1997 TYPE: WRITTEN INFORMAL VIOLATION INFORMATION: VIOLATION NUMBER: 1RESPONSIBLE: S - STATE DETERMINED: 97/03/1997DETERMINED BY: S - STATE CITATION: RESOLVED: 97/10/1997 TYPE: GENERATORS - PRE-TRANSPORT HAZARDOUS WASTE INFORMATION: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 SPILLS80 SEARCH ID:33 DIST/DIR:0.22 SW ELEVATION:725 MAP ID:15 NAME:CANTEEN CO.REV:9/26/00 ADDRESS:3621 TRYCLAN RD ID1:6923 CHARLOTTE NC ID2: MECKLENBURG STATUS:RESPONSE CONTACT:CANTEEN COMPANY PHONE: SOURCE: Site Details Page - 52 SITE INFORMATION OWNER/OPERATOR: CANTEEN COMPANY MR. L. R. LENZNER 222 NORTH LASALLE STREET CHICAGO IL 60601 DATE OF RELEASE: 8/1/89 DATE SUBMITTED: 9/17/91 DESCRIPTION OF INCIDENT: UPON REMOVAL OF UST, SOIL SAMPLES CONFIRMED CONTAMINATION. CONTAMINATION INFORMATION GROUNDWATER CONTAMINATED?: MAJOR SOIL CONTAMINATION?: MATERIAL INVOLVED (1): GASOLINE AMOUNT LOST (1): AMOUNT RECOVERED (1): MATERIAL INVOLVED (2): AMOUNT LOST (2): AMOUNT RECOVERED (1): MATERIAL INVOLVED (3): AMOUNT LOST (3): AMOUNT RECOVERED (3): NUMBER OF WELLS AFFECTED: 0 NAME(S) OF CONTAMINATED WELLS: PRIORITY INFORMATION: RISK SITE?: Y SITE PRIORITY: 060E PRIORITY CODE: L PRIORITY UPDATE: 5/15/98 STATUS INFORMATION: LAST MODIFIED: INCIDENT PHASE: RESPONSE NOV ISSUED: NORR ISSUED: 45 DAY REPORT: CORRECTIVE ACTION PLAN: CLOSURE REQ DATE: CLOSE-OUT REPORT: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:53 DIST/DIR:0.22 SW ELEVATION:725 MAP ID:15 NAME:CANTEEN FOOD SERVICES REV:6/1/12 ADDRESS:3621 TRYCLAN RD ID1:NCI-006923 CHARLOTTE NC 28217 ID2:6923 MECKLENBURG STATUS:RESPONSE CONTACT:L. R. LENZNER PHONE: SOURCE:NCDENR Site Details Page - 53 REGIONAL UST DATA UST NUMBER:MO-3117 INCIDENT NUMBER:6923 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:DPB REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: CANTEEN CO 222 NORTH LASALLE STREET CHICAGO ,IL , 60601 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY:060E RISK:L RISK OF INCIDENT:I INTERMEDIATE CONDITION:SURFACE WATER LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:8/2/1989 CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:0 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:41 DIST/DIR:0.22 SW ELEVATION:724 MAP ID:16 NAME:CANTEEN CORPORATION REV:6/1/12 ADDRESS:3631 TRYCLAN DR ID1:0-014703 CHARLOTTE NC 28210 ID2:00-0-0000014703 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:CANTEEN CORPORATION PHONE: SOURCE:NCDENR Site Details Page - 54 SITE INFORMATION TOTAL NUMBER OF TANKS: 1 CONTACT INFORMATION: CANTEEN CORPORATION 3631 TRYCLAN DRIVE CHARLOTTE NC 28210 TANK NUMBER: 1 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Gasoline, Gas Mix CAPACITY IN GALLONS: 8000 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES ARCHIVED INFORMATION AS OF 2011 TANK NUMBER: 1 INSTALLATION DATE: 19690601 CLOSED DATE: 19890331 STATUS: PERMANENTLY CLOSED CONTENTS: GASOLINE, GASOLINE MIXTURE CAPACITY IN GALLONS: 8000 COMMENTS: CONSTRUCTION MATERIAL: STEEL INTERIOR: UNKNOWN EXTERIOR: PAINT CORROSION PROTECTION: LEAK DETECTION: PIPING MATERIAL: STEEL PIPE CORROSION PROTECTION: PIPE LEAK DETECTION: OVERFLOW PROTECTION: FINANCIAL RESPONSIBILITY: CERTIFICATION TYPE: GPS SITING CONFIRMED:N PERSON CONFIRMING: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:42 DIST/DIR:0.22 SW ELEVATION:724 MAP ID:16 NAME:CANTEEN FOOD SERVICES REV:6/1/12 ADDRESS:3631 TRYCLAN DR ID1:MO-3117 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:L. R. LENZNER PHONE: SOURCE:NCDENR Site Details Page - 55 - Continued on next page - SITE INFORMATION REGIONAL UST DATA UST NUMBER:MO-3117 INCIDENT NUMBER:6923 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:DPB REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: CANTEEN CO 222 NORTH LASALLE STREET CHICAGO ,IL , 60601 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY:060E RISK:L RISK OF INCIDENT:I INTERMEDIATE CONDITION:SURFACE WATER LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:8/2/1989 CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:0 RESPONSIBLE OWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:42 DIST/DIR:0.22 SW ELEVATION:724 MAP ID:16 NAME:CANTEEN FOOD SERVICES REV:6/1/12 ADDRESS:3631 TRYCLAN DR ID1:MO-3117 CHARLOTTE NC 28217 ID2: MECKLENBURG STATUS:UNKNOWN CONTACT:L. R. LENZNER PHONE: SOURCE:NCDENR Site Details Page - 56 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 COMMENTS:1-8000-gallon DIESEL UST (old Coor 35.1228 80.5241)-benzene and xylenes in g water so low boiling pts assigned to ranking Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:46 DIST/DIR:0.22 SE ELEVATION:751 MAP ID:17 NAME:F N THOMPSON INC REV:6/1/12 ADDRESS:201 CLANTON RD ID1:0-002592 CHARLOTTE NC 28232 ID2:00-0-0000002592 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:F N THOMPSON INC PHONE: SOURCE:NCDENR Site Details Page - 57 - Continued on next page - SITE INFORMATION TOTAL NUMBER OF TANKS: 5 CONTACT INFORMATION: F N THOMPSON INC 201 CLANTON ROAD CHARLOTTE NC 28232 TANK NUMBER: 001 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Diesel CAPACITY IN GALLONS: 5000 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES TANK NUMBER: 002 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Diesel CAPACITY IN GALLONS: 3000 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES TANK NUMBER: 003 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Gasoline, Gas Mix CAPACITY IN GALLONS: 8000 TANK CONSTRUCTION:3 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:46 DIST/DIR:0.22 SE ELEVATION:751 MAP ID:17 NAME:F N THOMPSON INC REV:6/1/12 ADDRESS:201 CLANTON RD ID1:0-002592 CHARLOTTE NC 28232 ID2:00-0-0000002592 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:F N THOMPSON INC PHONE: SOURCE:NCDENR Site Details Page - 58 - Continued on next page - PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES TANK NUMBER: 004 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Oil, New/Used/Mix CAPACITY IN GALLONS: 550 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES TANK NUMBER: 005 ROOT TANK ID: TANK STATUS: INSTALLATION DATE: PERM CLOSED: CONTENTS: Diesel CAPACITY IN GALLONS: 4000 TANK CONSTRUCTION:3 PIPE CONSTRUCTION:4 MAIN TANK:NO COMPARTMENT TANK:NO MANIFOLD TANK: COMMERCIAL TANK:YES REGULATED TANK:YES REGIONAL UST DATA UST NUMBER:MO-0901 INCIDENT NUMBER: CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 UST SEARCH ID:46 DIST/DIR:0.22 SE ELEVATION:751 MAP ID:17 NAME:F N THOMPSON INC REV:6/1/12 ADDRESS:201 CLANTON RD ID1:0-002592 CHARLOTTE NC 28232 ID2:00-0-0000002592 MECKLENBURG STATUS:PERM CLOSED REMOVED CONTACT:F N THOMPSON INC PHONE: SOURCE:NCDENR Site Details Page - 59 - More Details Exist For This Site; Max Page Limit Reached - , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK: RISK OF INCIDENT: INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION: SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP: CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:0 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 COMMENTS:NO UST CLOSURE RECEIVED ARCHIVED INFORMATION AS OF 2011 TANK NUMBER: 001 INSTALLATION DATE: 19560512 CLOSED DATE: 19900415 STATUS: PERMANENTLY CLOSED CONTENTS: DIESEL, DIESEL MIXTURE CAPACITY IN GALLONS: 5000 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:55 DIST/DIR:0.27 SE ELEVATION:762 MAP ID:18 NAME:CATS MAINTENANCE FACITLITY REV:6/1/12 ADDRESS:3200 SOUTH BLVD ID1:NCI-027904 CHARLOTTE NC 28209 ID2:27904 MECKLENBURG STATUS:CLOSED OUT CONTACT:FRANK WARD PHONE: SOURCE:NCDENR Site Details Page - 60 REGIONAL UST DATA UST NUMBER:MO-7219 INCIDENT NUMBER:27904 CD NUMBER:256 REEL NUMBER:0 REGIONAL CONTACT:BLM REGIONAL OFFICE:MOR DATE OCCURRED:4/14/2005 RESPONSIBLE COMPANY: CHARLOTTE AREA TRANSIT SERVICE 4701 HEDGEMOR DRIVE SUITE 810 CHARLOTTE ,NC , 28209 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:NON COMMERCIAL REGULATED:NON REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:SOIL TO GROUNDWATER CLOSED REVIEW REQUESTED: CASE CLOSED:7/1/2005 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:4/14/2005 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:HEATING OIL CD NUMBER:256 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:-1 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:15 DIST/DIR:0.30 SE ELEVATION:755 MAP ID:19 NAME:CITY OF CHARLOTTE-SCALEYBARK SITE REV:6/8/12 ADDRESS:3610 SOUTH BLVD ID1:NONCD0002805 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 61 SITE INFORMATION DATE ADDED: 6/16/2008RESIDENCE ON SITE: NO DW WELL DISTANCE: > 1/4 MILESW INTAKE DISTANCE: NO INFO PROCESS CODE: MF MEDIA CONTAMINATEDCONTAMINANT TYPE SOILORGANICS SOILMETALS SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:57 DIST/DIR:0.30 NW ELEVATION:721 MAP ID:20 NAME:CONOCO STORE #33066 REV:6/1/12 ADDRESS:605 CLANTON RD ID1:NCI-011918 CHARLOTTE NC 28217 ID2:11918 MECKLENBURG STATUS:CLOSED OUT CONTACT:MR. PAUL TAYLOR PHONE: SOURCE:NCDENR Site Details Page - 62 REGIONAL UST DATA UST NUMBER:MO-4037 INCIDENT NUMBER:11918 CD NUMBER:73 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED:1/5/1994 RESPONSIBLE COMPANY: CONOCOPHILLIPS PO BOX 4784 HOUSTON ,TX , 772104784 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT:3/22/1994 VIOLATION:2/14/1995 PHASE REQUIRED: SITE PRIORITY:060E RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED:8/7/2000 CASE CLOSED:1/12/2001 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:1/5/1994 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:73 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:68 DIST/DIR:0.33 NE ELEVATION:750 MAP ID:21 NAME:PEPSI-COLA REV:6/1/12 ADDRESS:3101 GRIFFITH ST ID1:NCI-009747 CHARLOTTE NC 28203 ID2:9747 MECKLENBURG STATUS:CLOSED OUT CONTACT:MR. STU MENTZEL PHONE: SOURCE:NCDENR Site Details Page - 63 REGIONAL UST DATA UST NUMBER:MO-3731 INCIDENT NUMBER:9747 CD NUMBER:79 REEL NUMBER:0 REGIONAL CONTACT:MT REGIONAL OFFICE:MOR DATE OCCURRED:12/2/1991 RESPONSIBLE COMPANY: PEPSI-COLA 3101 GRIFFITH STREET CHARLOTTE ,NC , 28203 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY:E RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:10/22/2001 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:12/2/1991 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:OTHER PETROLEUM PROD. CD NUMBER:79 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:70 DIST/DIR:0.33 NE ELEVATION:751 MAP ID:22 NAME:SERVCO #01613 REV:6/1/12 ADDRESS:3040 SOUTH BLVD ID1:NCI-027648 CHARLOTTE NC 28209 ID2:27648 MECKLENBURG STATUS:CURRENT RECORD CONTACT:STEVE SAUNDERS PHONE:7049822197 SOURCE:NCDENR Site Details Page - 64 REGIONAL UST DATA UST NUMBER:MO-6930 INCIDENT NUMBER:27648 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:DPB REGIONAL OFFICE:MOR DATE OCCURRED:1/9/2004 RESPONSIBLE COMPANY: SERVCO DISTRIBUTING COMPANY PO BOX 310 ALBEMARLE ,NC , 28001 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED:2 SITE PRIORITY: RISK:I RISK OF INCIDENT:I INTERMEDIATE CONDITION:GROSS CONTAMINENT LAND USE:IND CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:YES LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:6/21/2004 CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:0 RESPONSIBLE OWNER:-1 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:71 DIST/DIR:0.33 NE ELEVATION:751 MAP ID:22 NAME:SERVCO STATION/S. BLVD REV:6/1/12 ADDRESS:3040 SOUTH BLVD ID1:NCI-008796 CHARLOTTE NC 28209 ID2:8796 MECKLENBURG STATUS:CLOSED OUT CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 65 REGIONAL UST DATA UST NUMBER:MO-3536 INCIDENT NUMBER:8796 CD NUMBER:2 REEL NUMBER:0 REGIONAL CONTACT:MT REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:8/28/1991 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:8/12/1991 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE: CD NUMBER:2 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 NFRAP SEARCH ID:4 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23 NAME:WILLIARD SMELTING CO.REV:8/1/12 ADDRESS:101 NEW BERN ST ID1:NCD003151651 CHARLOTTE NC 28203 ID2:0402603 MECKLENBURG STATUS:NFRAP-N CONTACT: PHONE: SOURCE:EPA Site Details Page - 66 DESCRIPTION: ACTION/QUALITY AGENCY/RPS START/RAA END ARCHIVE SITEEPA In-House3/12/1987 SITE REASSESSMENTState, Fund Financed6/14/2005 NFRAP: NO FURTHER REMEDIAL ACTION PLANNED DISCOVERYEPA Fund-Financed6/6/1985 PRELIMINARY ASSESSMENTState, Fund Financed5/15/1986 LOW PRIORITY FOR FURTHER ASSESSMENT SITE INSPECTIONState, Fund Financed3/12/1987 NFRAP: NO FURTHER REMEDIAL ACTION PLANNED Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:28 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23 NAME:WILLARD SMELTING CO.REV:6/8/12 ADDRESS:101 NEW BERN ST ID1:NCD003151651 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 67 SITE INFORMATION EPA ID:NCD003151651INCIDENT ID:85678 REP DISCOVERY DATE:15-MAY-01NOTICE DATE: NEXT DUE DATE:NEXT ACTION: INCIDENT COMMENTS:NO FILE AT MRO. INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO. 10/05: Apparently this site is going into the brownfields program. DATE ADDED: 1/12/1988RESIDENCE ON SITE: NO DW WELL DISTANCE: > 1/4 MILESW INTAKE DISTANCE: NO INFO PROCESS CODE: BATTERY DUMPING/MANUFACTURING - BATTERY BREAKING-LEAD RECOVERY OPERATIONS OR CASING DISPOSAL ACTIVITIES AND BATTERY MANUFACTURING MEDIA CONTAMINATEDCONTAMINANT TYPE SOILMETALS SITE CATEGORIES SPL SCORE: 27.86SPL: YES VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:75 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23 NAME:WILLARD INDUSTRIES (FORMER)REV:6/1/12 ADDRESS:101 NEW BERN ST ID1:NCI-017690 CHARLOTTE NC 28203 ID2:17690 MECKLENBURG STATUS:CLOSED OUT CONTACT:C/O LOYD CAUDLE PHONE:704-377-1200 SOURCE:NCDENR Site Details Page - 68 REGIONAL UST DATA UST NUMBER:MO-5173 INCIDENT NUMBER:17690 CD NUMBER:290 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED:8/19/1996 RESPONSIBLE COMPANY: NEW BERN REALTY COMPANY 2660 INTERST. TWR,121 W. TRADE CHARLOTTE ,NC , 28202 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED:1 SITE PRIORITY:20E RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:SOIL TO GROUNDWATER CLOSED REVIEW REQUESTED: CASE CLOSED:7/19/2006 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:NO LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:8/3/2006 CLEAN UP:8/19/1996 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:290 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:-1 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:76 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23 NAME:WILLARD SMELTING CO REV:10/1/01 ADDRESS:101 NEW BERN ST ID1:NCI-085678 CHARLOTTE NC ID2: MECKLENBURG STATUS:NOD CONTACT: PHONE: SOURCE: Site Details Page - 69 OWNER/OPERATOR: DATE OF RELEASE: DATE SUBMITTED: 5/15/2001 DESCRIPTION OF INCIDENT: NO FILE AT MRO. INACTIVE HAZ WASTE SITE, CONTACT DWM IN RALEIGH FOR ADDITIONAL INFO. CONTAMINATION INFORMATION GROUNDWATER CONTAMINATED?: NOD MAJOR SOIL CONTAMINATION?: MATERIAL INVOLVED (1): AMOUNT LOST (1): AMOUNT RECOVERED (1): MATERIAL INVOLVED (2): AMOUNT LOST (2): AMOUNT RECOVERED (2): MATERIAL INVOLVED (3): AMOUNT LOST (3): AMOUNT RECOVERED (3): NUMBER OF WELLS AFFECTED: 0 NAME(S) OF CONTAMINATED WELLS: PRIORITY INFORMATION: RISK SITE?: SITE PRIORITY: PRIORITY CODE: PRIORITY UPDATE: STATUS INFORMATION: LAST MODIFIED: INCIDENT PHASE: NOD NOV ISSUED: NORR ISSUED: 45 DAY REPORT: CORRECTIVE ACTION PLAN: CLOSURE REQ DATE: CLOSE-OUT REPORT: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:84 DIST/DIR:0.35 NE ELEVATION:756 MAP ID:23 NAME:WILLARD LEAD FACILITY REV:8/10/12 ADDRESS:101 NEW BERN ST ID1:NCBR-0206-087 CHARLOTTE NC ID2:09044-05-60 MECKLENBURG STATUS:FINALIZED CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 70 SITE INFORMATION PROSPECTIVE DEVELOPER:HARRIS MURR & VERMILLION, LLC FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS DESCRIPTION:Groundwater at the approximately 4.5-acre site is contaminated with chlorinated solvents, while soil shows metals contamination. The majority of the property has been vacant since 1996, the PD intends to redevelop the property into residential, retail, and possibly other commercial uses. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 NFRAP SEARCH ID:1 DIST/DIR:0.36 NE ELEVATION:752 MAP ID:24 NAME:BORDEN CHEMICAL PRINTING INK REV:8/1/12 ADDRESS:3013 GRIFFITH ST ID1:NCD049774375 CHARLOTTE NC 28203 ID2:0402783 MECKLENBURG STATUS:NFRAP-N CONTACT: PHONE: SOURCE:EPA Site Details Page - 71 DESCRIPTION: ACTION/QUALITY AGENCY/RPS START/RAA END ARCHIVE SITEEPA In-House2/5/1991 DISCOVERYEPA Fund-Financed8/1/1980 PRELIMINARY ASSESSMENTState, Fund Financed9/18/1985 LOW PRIORITY FOR FURTHER ASSESSMENT SITE INSPECTIONEPA Fund-Financed2/5/1991 NFRAP: NO FURTHER REMEDIAL ACTION PLANNED Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:13 DIST/DIR:0.36 NE ELEVATION:752 MAP ID:24 NAME:BORDEN CHEMICAL PRINTING INK REV:6/8/12 ADDRESS:3013 GRIFFITH ST ID1:NCD049774375 CHARLOTTE NC ID2: MECKLENBURG STATUS:NFA CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 72 SITE INFORMATION DATE ADDED: 1/12/1988RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: PAINTING & PRINTING - PAINTING AND PRINTING OPERATIONS WITH THE EXCEPTION OF FURNITURE FINISHING; ALSO INCLUDES PAINT MANUFACTURE AND BLENDING OPERATIONS MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: YES NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 NFRAP SEARCH ID:2 DIST/DIR:0.36 NE ELEVATION:727 MAP ID:25 NAME:PIEDMONT HEAT TREATING CORP REV:8/1/12 ADDRESS:3311 GRIFFITH ST ID1:NCD066309113 CHARLOTTE NC 28203 ID2:0402850 MECKLENBURG STATUS:NFRAP-N CONTACT: PHONE: SOURCE:EPA Site Details Page - 73 DESCRIPTION: ACTION/QUALITY AGENCY/RPS START/RAA END ARCHIVE SITEEPA In-House3/26/1990 DISCOVERYEPA Fund-Financed1/1/1984 PRELIMINARY ASSESSMENTState, Fund Financed7/18/1986 LOW PRIORITY FOR FURTHER ASSESSMENT SITE INSPECTIONEPA Fund-Financed3/26/1990 NFRAP: NO FURTHER REMEDIAL ACTION PLANNED Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:21 DIST/DIR:0.36 NE ELEVATION:727 MAP ID:25 NAME:PIEDMONT HEAT TREATING CORP REV:6/8/12 ADDRESS:3311 GRIFFITH ST ID1:NCD066309113 CHARLOTTE NC ID2: MECKLENBURG STATUS:NFA CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 74 SITE INFORMATION DATE ADDED: 1/12/1988RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MF MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: YES NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:59 DIST/DIR:0.37 NE ELEVATION:738 MAP ID:26 NAME:EPMORE INC.REV:6/1/12 ADDRESS:2941 S TRYON ST ID1:NCI-015304 CHARLOTTE NC 28203 ID2:15304 MECKLENBURG STATUS:RESPONSE CONTACT:WILLAIM MOORE PHONE: SOURCE:NCDENR Site Details Page - 75 REGIONAL UST DATA UST NUMBER:MO-4573 INCIDENT NUMBER:15304 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:DPB REGIONAL OFFICE:MOR DATE OCCURRED:2/2/1990 RESPONSIBLE COMPANY: EPMORE INC. PO BOX 36094 CHARLOTTE ,NC , 28236 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY:E RISK:L RISK OF INCIDENT:U INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:2/2/1990 CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:0 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:83 DIST/DIR:0.38 NE ELEVATION:726 MAP ID:27 NAME:RUSAK PROPERTY REV:3/31/08 ADDRESS:3004 BANK ST ID1:NCBR-0038 CHARLOTTE NC ID2: MECKLENBURG STATUS:FINALIZED CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 76 HISTORIC INFORMATIONA 1.21-acre parcel that is adjacent to the Marie G. Davis Middle School. The site is contaminated from historical operations as a metal plating facility. The PD intends to incorporate the adjacent parcels into the new middle school construction. The brownfields parcel will be the plaza entrance. SITE INFORMATION PROSPECTIVE DEVELOPER:CharMeck Board of Education FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS DESCRIPTION:A 1.21-acre parcel that is adjacent to the Marie G. Davis Middle School. The site is contaminated from historical operations as a metal plating facility. The PD intends to incorporate the adjacent parcels into the new middle school construction. The brownfields parcel will be the plaza entrance. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:19 DIST/DIR:0.38 NE ELEVATION:759 MAP ID:28 NAME:NIVENS PROPERTY REV:6/8/12 ADDRESS:3022 GRIFFITH ST ID1:NONCD0002204 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 77 SITE INFORMATION EPA ID:NONCD0002204INCIDENT ID:86905 REP DISCOVERY DATE:21-JAN-04NOTICE DATE: NEXT DUE DATE:NEXT ACTION:AFFIDAVIT INCIDENT COMMENTS:LOW LEVEL OF TCE & CHLOROFORM DISCOVERD IN MONITORING WELLS DURING ENVIRONMENTAL SITE ASSESSMENT. SOURCE UNKNOWN AT THIS TIME. WAITING ON RESPONSE FROM AFFIDAVIT TO PROPOERTY OWNER. DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:60 DIST/DIR:0.38 NE ELEVATION:759 MAP ID:28 NAME:FLOORING CONCEPTS REV:6/1/12 ADDRESS:3022 GRIFFITH ST ID1:NCI-027262 CHARLOTTE NC 28203 ID2:27262 MECKLENBURG STATUS:CLOSED OUT CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 78 REGIONAL UST DATA UST NUMBER:MO-1299 INCIDENT NUMBER:27262 CD NUMBER:24 REEL NUMBER:0 REGIONAL CONTACT:MT REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:8/7/1991 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:8/5/1991 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:24 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:82 DIST/DIR:0.38 NE ELEVATION:711 MAP ID:29 NAME:RUSAK PROPERTY REV:8/10/12 ADDRESS:3331 GRIFFITH ST ID1:NCBF-0811-003 CHARLOTTE NC ID2:07020-03-60 MECKLENBURG STATUS:FINALIZED CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 79 SITE INFORMATION PROSPECTIVE DEVELOPER:CHARMECK BOARD OF EDUCATION FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS DESCRIPTION:A 1.21-acre parcel that is adjacent to the Marie G. Davis Middle School. The site is contaminated from historical operations as a metal plating facility. The PD intends to incorporate the adjacent parcels into the new middle school construction. The brownfields parcel will be the plaza entrance. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:64 DIST/DIR:0.40 NE ELEVATION:760 MAP ID:30 NAME:MRS. J. SPENCER BELL/WF (RP-D)REV:6/1/12 ADDRESS:111 NEW BERN ST ID1:NCI-005176 CHARLOTTE NC 28203 ID2:5176 MECKLENBURG STATUS:RESPONSE CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 80 REGIONAL UST DATA UST NUMBER:MO-2887 INCIDENT NUMBER:5176 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:DPB REGIONAL OFFICE:MOR DATE OCCURRED:6/25/1989 RESPONSIBLE COMPANY: ` DECEASED MRS J. SPENSER BELL DECEASED DECEASED ,DE , SOURCE:LEAK, UST PETROLEUM TYPE:NON PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY:040E RISK:L RISK OF INCIDENT:U INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:6/25/1989 CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER: POLLUTANT TYPE: CD NUMBER:0 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:77 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31 NAME:BROWN S SOLVENT CO REV:9/30/10 ADDRESS:2935 GRIFFITH ST ID1:NCBR-0010 CHARLOTTE NC ID2: MECKLENBURG STATUS:FINALIZED CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 81 SITE INFORMATION PROSPECTIVE DEVELOPER:KATHRYN C BELL ESTATE FAC ELIGIBILITY:FINALIZED = FINALIZED BROWNFIELD AGREEMENTS DESCRIPTION:Former paint and solvent formulation facility with known solvent-impacted soil and groundwater. PD intends to initially renovate & reuse the existing structure for office/warehouse use, and ultimately raze the building and redevelop the site as a mixed office/retail complex in keeping with other redevelopment taking place in Charlotte s South End. Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:78 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31 NAME:BROWN S SOLVENT CO.REV:8/10/12 ADDRESS:2935 GRIFFITH ST ID1:05006-01-60 CHARLOTTE NC ID2:05006-01-60 MECKLENBURG STATUS:FINALIZED CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 82 SITE INFORMATION PROJECT NUMBER:05006-01-60 For more information please contact the NCDENR at (919) 707-8383 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 FEDBROWNFIELD SEARCH ID:86 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31 NAME:BROWN S SOLVENT COMPANY REV:10/1/08 ADDRESS:2935 GRIFFITH ST ID1:55781569-16 CHARLOTTE NC ID2:13562 MECKLENBURG STATUS:EPA BROWNFIELD CONTACT: PHONE: SOURCE:EPA Site Details Page - 83 - Continued on next page - SITE INFORMATION: RECIPIENT NAME:CHARLOTTE, CITY OF GRANT PROJ NAME:CHARLOTTE, NC CURRENT USE: FUTURE USE: PAST USAGE TYPE: FUTURE USAGE TYPE: START DATE:9/30/2004 COMPLETION DATE:9/30/2004 CLEANUP REQUIRED: ACCOMP TYPE:PHASE I ENVIRONMENTAL ASSESSMENT ACCOMP AMOUNT(ACRES): PROPERTY ID:13562PROPRETY SIZE:0.6 PARCEL NUMBER:147-017-06 CURRENT OWNER:OWNER ENTITY: CONTAMINATION FOUND PETROLEUM PROD:CONTROLLED SUB: ASBESTOS:PCBS: VOCS:LEAD: OTHER METALS:PAHS: OTHER:NONE: UNKNOWN: MEDIA FOUND SOIL:AIR: SURFACE WATER:GROUND WATER: DRINKING WATER:SEDIMENTS: CONTAMINANTS CLEANED UP PETROLEUM:CONTROLLED SUB: ASBESTOS:PCB: VOC:LEAD: OTHER METAL:PAHS: OTHER:UNKNOWN: NONE: MEDIA CLEANED UP SOIL:AIR: SURFACE WATER:GROUND WATER: DRINKING WATER:SEDIMENTS: UNKNOWN:NONE: STATE/TRIBAL PROG ID: STATE/TRIBE PROG ENROLL: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 FEDBROWNFIELD SEARCH ID:86 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31 NAME:BROWN S SOLVENT COMPANY REV:10/1/08 ADDRESS:2935 GRIFFITH ST ID1:55781569-16 CHARLOTTE NC ID2:13562 MECKLENBURG STATUS:EPA BROWNFIELD CONTACT: PHONE: SOURCE:EPA Site Details Page - 84 NOT ENROLLED: NFA ISSUE DATE: IC REQUIRED: IC IN PLACE:U IC IN PLACE DATE: PROPRIETARY CONTROLS: GOVERNMENTAL CONTROLS: ENFORCE PERM TOOLS: INFORM DEVICES: IC DATA ADDRESS: PHOTO AVAIL: VIDEO AVAIL: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 FEDBROWNFIELD SEARCH ID:87 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31 NAME:BROWN S SOLVENT COMPANY REV:5/1/12 ADDRESS:2935 GRIFFITH ST ID1:13562 CHARLOTTE NC 28203 ID2:13562 MECKLENBURG STATUS:EPA BROWNFIELD CONTACT: PHONE: SOURCE:EPA Site Details Page - 85 - Continued on next page - SITE INFORMATION: Y= YES N=NO U=UNKNOWN GRANT RECIPIENT:CHARLOTTE, CITY OF TYPE OF GRANT:ASSESSMENT TYPE OF FUNDING:N/A ACRES PROPERTY ID:13562 PROPERTY SIZE (ACRES):.6 LOCAL PROPERTY NUMBER:147-017-06 OWNERSHIP ENTITTY: CURRENT OWNER: DID OWNERSHIP CHANGE: SUPERFUND LANDOWNER LIABILITY CHANGE: PAST USE GREENSPACE (ACRES): PAST USE RESIDENTIAL(ACRES): PAST USE COMMERCIAL (ACRES): PAST USE INDUSTRIAL (ACRES): CONTAMINATION FOUND PETROLEUM:CONTROLLED SUBSTANCES: ASBESTOS:PCBs: VOCs:LEAD: OTHER METALS:PAHs: OTHER: OTHER DESCRIPTION: CONTAMINATION CLEANED UP: CLEANUP REQUIRED: PETROLEUM:CONTROLLED SUBSTANCES: ASBESTOS:PCBs: VOCs:LEAD: OTHER METALS:PAHs: OTHER: OTHER DESCRIPTION: MEDIA AFFECTED SOIL:AIR: SURFACE WATER:GROUND WATER: DRINKING WATER:SEDIMENTS: NO MEDIA:UNKNOWN: MEDIA CLEANED: SOIL:AIR: SURFACE WATER:GROUND WATER: DRINKING WATER:SEDIMENTS: STATE OR TRIBAL PROGRAM:STATE/TRIBAL ID: NFA/CLEANUP COMPL ISSUED:DATE ENROLLED IN PROG: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 FEDBROWNFIELD SEARCH ID:87 DIST/DIR:0.40 NE ELEVATION:755 MAP ID:31 NAME:BROWN S SOLVENT COMPANY REV:5/1/12 ADDRESS:2935 GRIFFITH ST ID1:13562 CHARLOTTE NC 28203 ID2:13562 MECKLENBURG STATUS:EPA BROWNFIELD CONTACT: PHONE: SOURCE:EPA Site Details Page - 86 INSTITUTIONAL CONTROL INFORMATION (IC) IC REQUIRED:PROPERTY CONTROLS: INFORMATIONAL DEVICES:GOVERNMENTAL CONTROLS: ENFORCEMENT/PERMIT TOOLS:IC IN PLACE:U DATE IC IN PLACE: CLEANUP START DATE:CLEANUP COMPLETION: ACRES CLEANED UP:CLEANUP FUNDING SOURCE: PROVIDING CLEANUP FUNDS:AMOUNT OF FUNDING: REDEVELOP START: FUTURE USE (acres) GREEN SPACE:RESIDENTIAL: COMMERCIAL:INDUSTRIAL: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 BROWNFIELD SEARCH ID:85 DIST/DIR:0.40 NE ELEVATION:759 MAP ID:32 NAME:WILLARD LEAD RIGHT-OF-WAY REV:8/10/12 ADDRESS:122 NEW BERN ST ID1:15014-11-60 CHARLOTTE NC ID2:15014-11-60 MECKLENBURG STATUS:FINALIZED CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 87 SITE INFORMATION PROJECT NUMBER:15014-11-60 For more information please contact the NCDENR at (919) 707-8383 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:58 DIST/DIR:0.42 SE ELEVATION:752 MAP ID:33 NAME:DIXIE WRECKER REV:6/1/12 ADDRESS:3801 SOUTH BLVD ID1:NCI-036241 CHARLOTTE NC 28217 ID2:36241 MECKLENBURG STATUS:CURRENT RECORD CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 88 REGIONAL UST DATA UST NUMBER:MO-2069 INCIDENT NUMBER:36241 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:DPB REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:INDUSTRIAL/COMMERCIAL CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:YES LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP: CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:0 RESPONSIBLE OWNER:-1 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 NFRAP SEARCH ID:3 DIST/DIR:0.43 NE ELEVATION:762 MAP ID:34 NAME:SWIFT ADHESIVES & COATINGS REV:8/1/12 ADDRESS:2917 YOUNGBLOOD ST ID1:NCD980557763 CHARLOTTE NC 28203 ID2:0403025 MECKLENBURG STATUS:NFRAP-N CONTACT: PHONE: SOURCE:EPA Site Details Page - 89 DESCRIPTION: ACTION/QUALITY AGENCY/RPS START/RAA END ARCHIVE SITEEPA In-House9/9/1987 DISCOVERYEPA Fund-Financed6/1/1981 PRELIMINARY ASSESSMENTState, Fund Financed9/9/1987 NFRAP: NO FURTHER REMEDIAL ACTION PLANNED Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:25 DIST/DIR:0.43 NE ELEVATION:762 MAP ID:34 NAME:SWIFT ADHESIVES & COATINGS/CHARLOTTE REV:6/8/12 ADDRESS:2917 YOUNGBLOOD ST ID1:NCD980557763 CHARLOTTE NC ID2: MECKLENBURG STATUS:NFA CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 90 SITE INFORMATION DATE ADDED: 1/12/1988RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: PAINTING & PRINTING - PAINTING AND PRINTING OPERATIONS WITH THE EXCEPTION OF FURNITURE FINISHING; ALSO INCLUDES PAINT MANUFACTURE AND BLENDING OPERATIONS MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: YES NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:27 DIST/DIR:0.43 NE ELEVATION:748 MAP ID:35 NAME:TERRELL MACHINE SHOP REV:6/8/12 ADDRESS:3000 SOUTH BLVD ID1:NONCD0000011 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 91 SITE INFORMATION EPA ID:NONCD0000011INCIDENT ID:5015 REP DISCOVERY DATE:24-APR-89NOTICE DATE: NEXT DUE DATE:NEXT ACTION:MONITOR REPORT INCIDENT COMMENTS:CHLORINATED SOLVENTS, OFF-SITE PETRO. CONT.?;SELF-INITIATED REM. IN PLACE AND MONITORING. 2002: ACCEPTED INTO BROWNFIELDS PROGRAM. DATE ADDED: 3/9/1990RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MF MEDIA CONTAMINATEDCONTAMINANT TYPE SOILORGANICS GROUNDWATERORGANICS SITE CATEGORIES SPL SCORE: 39.62SPL: YES VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:73 DIST/DIR:0.43 NE ELEVATION:748 MAP ID:35 NAME:TERRELL MACHINE COMPANY REV:10/1/01 ADDRESS:0 P. O. BOX 240868 ID1:NCI-005015 CHARLOTTE NC ID2: MECKLENBURG STATUS:RESPONSE CONTACT:A. E. TERRELL PHONE: SOURCE: Site Details Page - 92 OWNER/OPERATOR: A. E. TERRELL TERRELL MACHINE COMPANY 1515 MOCKINGBIRD LANE CHARLOTTE NC DATE OF RELEASE: 4/24/1989 DATE SUBMITTED: 4/27/1989 DESCRIPTION OF INCIDENT: CHLORINATED SOLVENTS, OFF-SITE PETRO. CONT.?;SELF-INITIATED REM. IN PLACE AND MONITORING. 2002: ACCEPTED INTO BROWNFIELDS PROGRAM. CONTAMINATION INFORMATION GROUNDWATER CONTAMINATED?: Y MAJOR SOIL CONTAMINATION?: MATERIAL INVOLVED (1): AMOUNT LOST (1): AMOUNT RECOVERED (1): MATERIAL INVOLVED (2): AMOUNT LOST (2): AMOUNT RECOVERED (2): MATERIAL INVOLVED (3): AMOUNT LOST (3): AMOUNT RECOVERED (3): NUMBER OF WELLS AFFECTED: 0 NAME(S) OF CONTAMINATED WELLS: PRIORITY INFORMATION: RISK SITE?: SITE PRIORITY: 80 PRIORITY CODE: E PRIORITY UPDATE: STATUS INFORMATION: LAST MODIFIED: INCIDENT PHASE: RESPONSE NOV ISSUED: NORR ISSUED: 45 DAY REPORT: CORRECTIVE ACTION PLAN: CLOSURE REQ DATE: CLOSE-OUT REPORT: Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:72 DIST/DIR:0.43 NE ELEVATION:754 MAP ID:36 NAME:SUMMERFIELD S AUTO REV:6/1/12 ADDRESS:3017 SOUTH ID1:NCI-005261 CHARLOTTE NC 28209 ID2:5261 MECKLENBURG STATUS:RESPONSE CONTACT:MS. MARTHA REID/MR REID-DECEAS PHONE: SOURCE:NCDENR Site Details Page - 93 REGIONAL UST DATA UST NUMBER:MO-2899 INCIDENT NUMBER:5261 CD NUMBER:287 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: THE CUPBOARD, INC. 811 HILLSIDE AVENUE CHARLOTTE ,NC , 28209 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT:11/14/1989 VIOLATION: PHASE REQUIRED: SITE PRIORITY:110D RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION:GROSS CONTAMINENT LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:RESIDENTIAL CLOSED REVIEW REQUESTED: CASE CLOSED:9/14/2006 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:YES LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:10/10/2006 CLEAN UP:4/21/1989 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:287 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:14 DIST/DIR:0.44 NE ELEVATION:755 MAP ID:37 NAME:CHARLOTTE BATTERY REV:6/8/12 ADDRESS:2926 YOUNGBLOOD ST ID1:NONCD0001150 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 94 SITE INFORMATION DATE ADDED: 12/6/2005RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: BATTERY DUMPING/MANUFACTURING - BATTERY BREAKING-LEAD RECOVERY OPERATIONS OR CASING DISPOSAL ACTIVITIES AND BATTERY MANUFACTURING MEDIA CONTAMINATEDCONTAMINANT TYPE KNOWN/SUSPECTED SITE CATEGORIES SPL SCORE: 33.67SPL: YES VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:52 DIST/DIR:0.45 SE ELEVATION:754 MAP ID:38 NAME:C.M. ALLEN CONSTUCTION REV:6/1/12 ADDRESS:3813 SOUTH BLVD ID1:NCI-008582 CHARLOTTE NC 28209 ID2:8582 MECKLENBURG STATUS:RESPONSE CONTACT:MR. BILL JOHNS PHONE: SOURCE:NCDENR Site Details Page - 95 REGIONAL UST DATA UST NUMBER:MO-3407 INCIDENT NUMBER:8582 CD NUMBER:320 REEL NUMBER:0 REGIONAL CONTACT:BLM REGIONAL OFFICE:MOR DATE OCCURRED:2/20/1991 RESPONSIBLE COMPANY: NISBET OIL COMPANY PO BOX 35367 CHARLOTTE ,NC , 28235 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY:E? RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:RESIDENTIAL CLOSED REVIEW REQUESTED: CASE CLOSED:1/16/2007 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:YES LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:1/23/2007 CLEAN UP:2/20/1991 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:320 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:63 DIST/DIR:0.47 SE ELEVATION:750 MAP ID:39 NAME:MEJIA AUTOMOTIVE PROPERTY REV:6/1/12 ADDRESS:3821 SOUTH BLVD ID1:NCI-036617 CHARLOTTE NC 28209 ID2:36617 MECKLENBURG STATUS:ARCHIVED CONTACT:UNKNOWN PHONE: SOURCE:NCDENR Site Details Page - 96 REGIONAL UST DATA UST NUMBER:MO-8009 INCIDENT NUMBER:36617 CD NUMBER:393 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED:6/30/2008 RESPONSIBLE COMPANY: UNKNOWN ,NC , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED:1 SITE PRIORITY: RISK:U RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:SOIL TO GROUNDWATER CLOSED REVIEW REQUESTED: CASE CLOSED:1/28/2009 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:NO LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:2/5/2009 CLEAN UP: CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:OTHER PETROLEUM PROD. CD NUMBER:393 RESPONSIBLE OWNER:-1 RESPONSIBLE OPERATOR:-1 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:62 DIST/DIR:0.48 NE ELEVATION:749 MAP ID:40 NAME:KRISPY KREME DOUGHNUT REV:6/1/12 ADDRESS:2901 SOUTH BLVD ID1:NCI-027265 CHARLOTTE NC 28217 ID2:27265 MECKLENBURG STATUS:CLOSED OUT CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 97 REGIONAL UST DATA UST NUMBER:MO-1401 INCIDENT NUMBER:27265 CD NUMBER:24 REEL NUMBER:0 REGIONAL CONTACT:MT REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: , , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:BOTH AT SAME SITE REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED:4/20/1992 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:4/20/1992 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:24 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:74 DIST/DIR:0.48 SE ELEVATION:752 MAP ID:41 NAME:THE APPLE BUILDING REV:6/1/12 ADDRESS:3809 WEONA AVE ID1:NCI-010926 CHARLOTTE NC 28209 ID2:10926 MECKLENBURG STATUS:RESPONSE CONTACT:RODGER JOHNSON PHONE: SOURCE:NCDENR Site Details Page - 98 REGIONAL UST DATA UST NUMBER:MO-3891 INCIDENT NUMBER:10926 CD NUMBER:0 REEL NUMBER:0 REGIONAL CONTACT:BLM REGIONAL OFFICE:MOR DATE OCCURRED:6/28/1993 RESPONSIBLE COMPANY: APPLE MANAGEMENT 290 CYPRESS GARDENS BLVD WINTERHAVEN ,FL , 33880 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:NON COMMERCIAL REGULATED:NON REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:U INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA: CLOSED REVIEW REQUESTED: CASE CLOSED: CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:6/28/1993 CURRENT STATUS:CURRENT RECORD RBCA GROUNDWATER: POLLUTANT TYPE:HEATING OIL CD NUMBER:0 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:66 DIST/DIR:0.50 NE ELEVATION:769 MAP ID:42 NAME:PEPSI BOTTLING COMPANY REV:6/1/12 ADDRESS:2820 SOUTH BLVD ID1:NCI-027982 CHARLOTTE NC 28224 ID2:27982 MECKLENBURG STATUS:CLOSED OUT CONTACT: PHONE: SOURCE:NCDENR Site Details Page - 99 REGIONAL UST DATA UST NUMBER:MO-7324 INCIDENT NUMBER:27982 CD NUMBER:288 REEL NUMBER:0 REGIONAL CONTACT:BLM REGIONAL OFFICE:MOR DATE OCCURRED:10/12/2005 RESPONSIBLE COMPANY: PEPSI COLA BOTTLING COMPANY ,NC , SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:INDUSTRIAL/COMMERCIAL CLOSED REVIEW REQUESTED: CASE CLOSED:6/29/2006 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:YES LEAK DISCOVERED:0 LAND USE RESTRICTION FILED:7/6/2006 CLEAN UP:10/6/2005 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:288 RESPONSIBLE OWNER:-1 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:67 DIST/DIR:0.50 NE ELEVATION:769 MAP ID:42 NAME:PEPSI COLA BOTTLING COMPANY REV:6/1/12 ADDRESS:2820 SOUTH BLVD ID1:NCI-027939 CHARLOTTE NC 28209 ID2:27939 MECKLENBURG STATUS: CONTACT:STUART MENZEL PHONE:7045236761 SOURCE:NCDENR Site Details Page - 100 REGIONAL UST DATA UST NUMBER:MO-7281 INCIDENT NUMBER:27939 CD NUMBER:323 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED:9/6/2005 RESPONSIBLE COMPANY: PEPSI COLA BOTTLING OF CHARLOT 2820 SOUTH BLVD/PO BOX 241167 CHARLOTTE ,NC , 28224 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:COMMERCIAL REGULATED:REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY: RISK:U RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE:IND CORRECTIVE ACTION PLAN: RBCA:RESIDENTIAL CLOSED REVIEW REQUESTED: CASE CLOSED:5/25/2007 CONTAMINATION:GROUNDWATER/BOTH SUPPLY WELLS:0 MTBE IN WELL:0 MTBE IN GROUNDWATER:NO LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP: CURRENT STATUS:ARCHIVED RBCA GROUNDWATER:CLEANUPS TO ALTERNATE STANDARDS POLLUTANT TYPE:GASOLINE/DIESEL/KEROSENE CD NUMBER:323 RESPONSIBLE OWNER:-1 RESPONSIBLE OPERATOR:-1 RESPONSIBLE LANDOWNER:-1 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 LUST SEARCH ID:69 DIST/DIR:0.50 SE ELEVATION:716 MAP ID:43 NAME:ROBERT MAHONEY RESIDENCE REV:6/1/12 ADDRESS:3326 ANSON ST ID1:NCI-009125 CHARLOTTE NC 28209 ID2:9125 MECKLENBURG STATUS:CLOSED OUT CONTACT:ROBERT MAHONEY PHONE:7045218257 SOURCE:NCDENR Site Details Page - 101 REGIONAL UST DATA UST NUMBER:MO-3621 INCIDENT NUMBER:9125 CD NUMBER:80 REEL NUMBER:0 REGIONAL CONTACT:AJS REGIONAL OFFICE:MOR DATE OCCURRED: RESPONSIBLE COMPANY: 3326 ANSON STREET CHARLOTTE ,NC , 28209 SOURCE:LEAK, UST PETROLEUM TYPE:PETROLEUM COMMERCIAL/NONCOMMERCIAL:NON COMMERCIAL REGULATED:NON REGULATED REGULATORY REQUIREMENT: VIOLATION: PHASE REQUIRED: SITE PRIORITY:E? RISK:L RISK OF INCIDENT:L INTERMEDIATE CONDITION: LAND USE: CORRECTIVE ACTION PLAN: RBCA:SOIL TO GROUNDWATER CLOSED REVIEW REQUESTED: CASE CLOSED:5/25/1999 CONTAMINATION:SOIL SUPPLY WELLS:0 MTBE IN WELL: MTBE IN GROUNDWATER:UNKNOWN LEAK DISCOVERED:0 LAND USE RESTRICTION FILED: CLEAN UP:10/2/1992 CURRENT STATUS:ARCHIVED RBCA GROUNDWATER: POLLUTANT TYPE:HEATING OIL CD NUMBER:80 RESPONSIBLE OWNER:0 RESPONSIBLE OPERATOR:0 RESPONSIBLE LANDOWNER:0 Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:17 DIST/DIR:0.53 SE ELEVATION:765 MAP ID:44 NAME:MITCHELLS FORMAL WEAR (AFTER HOURS)REV:6/8/12 ADDRESS:115 SCALEYBARK RD ID1:NONCD0002084 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 102 SITE INFORMATION EPA ID:NONCD0002084INCIDENT ID:18799 REP DISCOVERY DATE:25-JUN-98NOTICE DATE: NEXT DUE DATE:NEXT ACTION: INCIDENT COMMENTS:PCE 17,000 PPB IN GW; PET. COMPOUNDS ALSO PRESENT IN GW MAY BE OFFSITE SOURCE; HISTORY OF PCE USE ON SITE BY AT LEAST THREE DRY CLEANER OPERATORS;SENT TO DRY CLEANERS FUND 1/99. HAS UIC PERMIT (WI0300056) FOR PERMANGANATE INJECTION (AKA AFTER HOURS FORMAL WEAR). 10/02: Certified into DSCA. 3/05: Prospective developer filed to enter Brownfields Program. 1/07: new UIC application to inject BOS-100, a combination of activated carbon and iron. DWM Brownfields and DSCA are both involved. Carolyn Minnich is project manager for Brownfields and it appears that Brownfields redevelopment associated with Scaleybark light rail station is driving this project forward on a fast track. DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:YES NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:18 DIST/DIR:0.62 NE ELEVATION:750 MAP ID:45 NAME:NCDOT ASPHALT SITE #57 - REA CONSTRUCTIO REV:6/8/12 ADDRESS:2701 YOUNGBLOOD CT ID1:NONCD0002172 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 103 SITE INFORMATION EPA ID:NONCD0002172INCIDENT ID:87948 REP DISCOVERY DATE:17-OCT-06NOTICE DATE: NEXT DUE DATE:NEXT ACTION: INCIDENT COMMENTS:ADDITIONAL AREA OF PRETOLEUM CONTAMINATED SOIL WAS DISCOVERED ON SITE. GW ALSO IMPACTED. LEAD ALSO DETECTED IN SOIL ABOVE BACKGROUND. EPA ID:NONCD0002172INCIDENT ID:17443 REP DISCOVERY DATE:05-JUN-97NOTICE DATE: NEXT DUE DATE:31-JUL-06NEXT ACTION:Annual Monitoring Report INCIDENT COMMENTS:PER NCDOT MOA CSA SUBMITTED EXTENT DEF. MINOR ADDTL WORK THEN CAP-ADDTL 2L MUST GO OUT FOR PET. COMPOUNDS DETECTED DURING INVEST.POSSIBLY INVOVLEMENT WITH REA IN FUTURE;WSW SURVEY 6/18/98 NO 1500 FT WSWS. 2002-05: L-Cap approved, soil contam is below site specific cleanup levels; semi-annual monitoring with annual reports due at end of July; concentrations are generally edging slightly downward. 2006-07 update: site is entering Brownfields agreement, MWs have been abandoned also petroleum issues at this same location; reports submitted in 2006 have not been reviewed. DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:24 DIST/DIR:0.62 NE ELEVATION:750 MAP ID:45 NAME:SUTTON PARK GROCERY REV:6/8/12 ADDRESS:2701 YOUNGBLOOD ST ID1:NONCD0002380 MONROE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 104 SITE INFORMATION DATE ADDED: 5/20/2009RESIDENCE ON SITE: NO DW WELL DISTANCE: > 1/4 MILESW INTAKE DISTANCE: NO INFO PROCESS CODE: OTHER - OTHER VARIOUS PROCESSES SUCH AS OTHER MANUFACTURING, SANITATION SERVICE COMPANIES, AND FIRE TRAINING GROUNDS; ALSO INCLUDES ALL SITES WHERE THE PROCESS CAUSING THE CONTAMINATION IS UNKNOWN MEDIA CONTAMINATEDCONTAMINANT TYPE GROUNDWATERORGANICS SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:12 DIST/DIR:0.62 SW ELEVATION:701 MAP ID:46 NAME:BALDOR ELECTRIC COMPANY REV:6/8/12 ADDRESS:3821 BARRINGER RD ID1:NONCD0001132 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 105 SITE INFORMATION EPA ID:NONCD0001132INCIDENT ID:14993 REP DISCOVERY DATE:02-DEC-92NOTICE DATE:3/22/1994 NEXT DUE DATE:NEXT ACTION:REQUEST CSA INCIDENT COMMENTS:TCE,PCE,1,1,1-TCA, NOV NEEDS TO BE SENT; BALDOR MOVED ITS OPERATION IN 1992; OTHER OPERATORS BEFORE BALDOR INCLUDE POWERTRON (1974-1980)AND CONTRAVES GOERZ (1980-88); ALL THREE COMPANIES MANUFACTURED ELECTRIC MOTORS. 2/03: BROWNFIELDS AGREEMENT IN PLACE. DATE ADDED: 12/2/2005RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: OTHER - OTHER VARIOUS PROCESSES SUCH AS OTHER MANUFACTURING, SANITATION SERVICE COMPANIES, AND FIRE TRAINING GROUNDS; ALSO INCLUDES ALL SITES WHERE THE PROCESS CAUSING THE CONTAMINATION IS UNKNOWN MEDIA CONTAMINATEDCONTAMINANT TYPE GROUNDWATERORGANICS SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:16 DIST/DIR:0.67 NE ELEVATION:704 MAP ID:47 NAME:MECKLENBURG CO. OIL SPILL BASIN CREE REV:6/8/12 ADDRESS:626 MILLER ST ID1:NCD986189983 CHARLOTTE NC ID2: MECKLENBURG STATUS:NFA CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 106 SITE INFORMATION DATE ADDED: 11/3/1992RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: PETROCHEMICALS - PETROCHEMICAL PRODUCTION, REFINING, TRANSPORT, STORAGE AND DISPOSAL MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: YES NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:22 DIST/DIR:0.75 NE ELEVATION:765 MAP ID:48 NAME:QUALEX REV:6/8/12 ADDRESS:2519 DISTRIBUTION ST ID1:NONCD0002348 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 107 SITE INFORMATION EPA ID:NONCD0002348INCIDENT ID:87247 REP DISCOVERY DATE:07-FEB-05NOTICE DATE:2/18/2005 NEXT DUE DATE:23-MAY-05NEXT ACTION:CSA INCIDENT COMMENTS:LARGE PHOTO PROCESSING FACILITY. SOIL CONTAMINATION INCLUDES SILVER,CYANIDE, SULFATE AND DRO & MOTOR OIL TPH. ONLY GROUNDWATER CONTAMINATION ABOVE 2L IS SULFATE. DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:10 DIST/DIR:0.81 NE ELEVATION:763 MAP ID:49 NAME:AIR LIQUIDE REV:6/8/12 ADDRESS:2414 SOUTH BLVD ID1:NONCD0001231 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 108 SITE INFORMATION EPA ID:NONCD0001231INCIDENT ID:22103 REP DISCOVERY DATE:02-JUN-00NOTICE DATE: NEXT DUE DATE:NEXT ACTION: INCIDENT COMMENTS:TCE, PCE, 1,1-DCE, C TET, 1,1,1,-TCA, CHLOROFORM FOUND IN GW DURING PHASE II ASSESSMENT FOR SALE OF PROPERTY; SOURCE MAY BE OFFSITE. DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:26 DIST/DIR:0.87 NE ELEVATION:770 MAP ID:50 NAME:TACO BELL #2 REV:6/8/12 ADDRESS:2405 SOUTH BLVD ID1:NONCD0002573 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 109 SITE INFORMATION EPA ID:NONCD0002573INCIDENT ID:85197 REP DISCOVERY DATE:17-NOV-98NOTICE DATE: NEXT DUE DATE:NEXT ACTION: INCIDENT COMMENTS:8 PPB PCE DETECTED DURING LSA FOR UST RELEASE #14261. DATE ADDED: 3/20/2008RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: MEDIA CONTAMINATEDCONTAMINANT TYPE SITE CATEGORIES SPL SCORE: SPL: NO VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: YESNFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Site Detail Report Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 STATE SEARCH ID:23 DIST/DIR:1.00 NE ELEVATION:777 MAP ID:51 NAME:SOUTHSIDE INVESTMENTS LLC REV:6/8/12 ADDRESS:2222 SOUTH BLVD ID1:NONCD0001076 CHARLOTTE NC ID2: MECKLENBURG STATUS:ACTIVE CONTACT: PHONE: SOURCE:NC DENR Site Details Page - 110 SITE INFORMATION DATE ADDED: 6/1/2001RESIDENCE ON SITE: NO DW WELL DISTANCE: NO INFOSW INTAKE DISTANCE: NO INFO PROCESS CODE: FURNITURE INDUSTRY - FURNITURE MANUFACTURING, FINISHING AND RESTORATION MEDIA CONTAMINATEDCONTAMINANT TYPE GROUNDWATERORGANICS GROUNDWATERMETALS SOILORGANICS SOILMETALS SITE CATEGORIES SPL SCORE: 38.05SPL: YES VOLUNTARY CLEANUP: NOREMEDIAL ACTION: EVALUATIONS PENDING: NONFA: NO NFA W/COVENANT: NODWQ: NO SW SECTION: NONON NPL CERCLA: NO NPL SITE: NONON TSD HAZ WASTE: NO TSD: NORADIATION PROTECTION: NO BROWNFIELD: DUPLICATE: NO UST LEAD:NODSCA LEAD:NO NON HAZ SUB SITE EP:NON HAZ SUB SITE VOL: NON HAZ SUB SITE NFA:NO POLLUTANT ONLY SITE-OPEN:0 POLLUTANT ONLY SITE -NFA RESTRICTED:0 ORDERS, AGREEMENTS, AND SOLICITATIONS Environmental FirstSearch Descriptions NPL: EPA NATIONAL PRIORITY LIST - The National Priorities List is a list of the worst hazardous waste sites that have been identified by Superfund. Sites are only put on the list after they have been scored using the Hazard Ranking System (HRS), and have been subjected to public comment. Any site on the NPL is eligible for cleanup using Superfund Trust money. A Superfund site is any land in the United States that has been contaminated by hazardous waste and identified by the Environmental Protection Agency (EPA) as a candidate for cleanup because it poses a risk to human health and/or the environment.FINAL - Currently on the Final NPLPROPOSED - Proposed for NPL NPL DELISTED: EPA NATIONAL PRIORITY LIST Subset - Database of delisted NPL sites. The National Oil and Hazardous Substances Pollution Contingency Plan (NCP) establishes the criteria that the EPA uses to delete sites from the NPL. In accordance with 40 CFR 300.425.(e), sites may be deleted from the NPL where no further response is appropriate.DELISTED - Deleted from the Final NPL CERCLIS: EPA COMPREHENSIVE ENVIRONMENTAL RESPONSE COMPENSATION AND LIABILITY INFORMATION SYSTEM (CERCLIS)- CERCLIS is a database of potential and confirmed hazardous waste sites at which the EPA Superfund program has some involvement. It contains sites that are either proposed to be or are on the National Priorities List (NPL) as well as sites that are in the screening and assessment phase for possible inclusion on the NPL.PART OF NPL- Site is part of NPL siteDELETED - Deleted from the Final NPLFINAL - Currently on the Final NPLNOT PROPOSED - Not on the NPLNOT VALID - Not Valid Site or IncidentPROPOSED - Proposed for NPLREMOVED - Removed from Proposed NPLSCAN PLAN - Pre-proposal SiteWITHDRAWN - Withdrawn NFRAP: EPA COMPREHENSIVE ENVIRONMENTAL RESPONSE COMPENSATION AND LIABILITY INFORMATION SYSTEM ARCHIVED SITES - database of Archive designated CERCLA sites that, to the best of EPA's knowledge, assessment has been completed and has determined no further steps will be taken to list this site on the National Priorities List (NPL). This decision does not necessarily mean that there is no hazard associated with a given site; it only means that, based upon available information, the location is not judged to be a potential NPL site.NFRAP – No Further Remedial Action PlanP - Site is part of NPL siteD - Deleted from the Final NPLF - Currently on the Final NPLN - Not on the NPLO - Not Valid Site or IncidentP - Proposed for NPLR - Removed from Proposed NPLS - Pre-proposal SiteW – Withdrawn RCRA COR ACT: EPA RESOURCE CONSERVATION AND RECOVERY INFORMATION SYSTEM SITES - Database of hazardous waste information contained in the Resource Conservation and Recovery Act Information (RCRAInfo), a national program management and inventory system about hazardous waste handlers. In general, all generators, transporters, treaters, storers, and disposers of hazardous waste are required to provide information about their activities to state environmental agencies. These agencies, in turn pass on the information to regional and national EPA offices. This regulation is governed by the Resource Conservation and Recovery Act (RCRA), as amended by the Hazardous and Solid Waste Amendments of 1984.RCRAInfo facilities that have reported violations and subject to corrective actions. RCRA TSD: EPA RESOURCE CONSERVATION AND RECOVERY INFORMATION SYSTEM TREATMENT, STORAGE, and DISPOSAL FACILITIES. - Database of hazardous waste information contained in the Resource Conservation and Recovery Act Information (RCRAInfo), a national program management and inventory system about hazardous waste handlers. In general, all generators, transporters, treaters, storers, and disposers of hazardous waste are required to provide information about their activities to state environmental agencies. These agencies, in turn pass on the information to regional and national EPA offices. This regulation is governed by the Resource Conservation and Recovery Act (RCRA), as amended by the Hazardous and Solid Waste Amendments of 1984.Facilities that treat, store, dispose, or incinerate hazardous waste. RCRA GEN: EPA/MA DEP/CT DEP RESOURCE CONSERVATION AND RECOVERY INFORMATION SYSTEM GENERATORS - Database of hazardous waste information contained in the Resource Conservation and Recovery Act Information (RCRAInfo), a national program management and inventory system about hazardous waste handlers. In general, all generators, transporters, treaters, storers, and disposers of hazardous waste are required to provide information about their activities to state environmental agencies. These agencies, in turn pass on the information to regional and national EPA offices. This regulation is governed by the Resource Conservation and Recovery Act (RCRA), as amended by the Hazardous and Solid Waste Amendments of 1984.Facilities that generate or transport hazardous waste or meet other RCRA requirements.LGN - Large Quantity GeneratorsSGN - Small Quantity GeneratorsVGN – Conditionally Exempt Generator.Included are RAATS (RCRA Administrative Action Tracking System) and CMEL (Compliance Monitoring & Enforcement List) facilities. CONNECTICUT HAZARDOUS WASTE MANIFEST – Database of all shipments of hazardous waste within, into or from Connecticut. The data includes date of shipment, transporter and TSD info, and material shipped and quantity. This data is appended to the details of existing generator records. MASSACHUSETTES HAZARDOUS WASTE GENERATOR – database of generators that are regulated under the MA DEP. VQN-MA = generates less than 220 pounds or 27 gallons per month of hazardous waste or waste oil.SQN-MA = generates 220 to 2,200 pounds or 27 to 270 gallons per month of waste oil.LQG-MA = generates greater than 2,200 lbs of hazardous waste or waste oil per month. Fed Brownfield: EPA BROWNFIELD MANAGEMENT SYSTEM (BMS) - database designed to assist EPA in collecting, tracking, and updating information, as well as reporting on the major activities and accomplishments of the various Brownfield grant Programs./n CLEANUPS IN MY COMMUNITY (subset) - Sites, facilities and properties that have been contaminated by hazardous materials and are being, or have been, cleaned up under EPA's brownfield’s program. ERNS: EPA/NRC EMERGENCY RESPONSE NOTIFICATION SYSTEM (ERNS) - Database of incidents reported to the National Response Center. These incidents include chemical spills, accidents involving chemicals (such as fires or explosions), oil spills, transportation accidents that involve oil or chemicals, releases of radioactive materials, sightings of oil sheens on bodies of water, terrorist incidents involving chemicals, incidents where illegally dumped chemicals have been found, and drills intended to prepare responders to handle these kinds of incidents. Data since January 2001 has been received from the National Response System database as the EPA no longer maintains this data. Tribal Lands: DOI/BIA INDIAN LANDS OF THE UNITED STATES - Database of areas with boundaries established by treaty, statute, and (or) executive or court order, recognized by the Federal Government as territory in which American Indian tribes have primary governmental authority. The Indian Lands of the United States map layer shows areas of 640 acres or more, administered by the Bureau of Indian Affairs. Included are Federally-administered lands within a reservation which may or may not be considered part of the reservation.BUREAU OF INDIAN AFFIARS CONTACT - Regional contact information for the Bureau of Indian Affairs offices. State/Tribal Sites: NCDENR STATE INACTIVE HAZARDOUS SITES LIST - database of sites and Facilities that are being investigated due to reported releases of Hazardous substances. Included within this Inactive Hazardous Waste Sites Inventory database are the following classifications: Inactive Hazardous Waste Sites (IHS), No Further Action Sites (NFA), Duplicate Sites (DS), Inactive Hazardous Waste Sites Priority List Sites (SPL) State Spills 90: NCDENR INCIDENT MANAGEMENT DATA (UST and Groundwater) - database of possible releases/spills of contaminants. The data includes media effected, material released, source and site priority. State/Tribal SWL: NCDENR ALL PERMITTED SOLID WASTE FACILITIES - database of C&D Landfill, Compost, House Hold Hazardous Waste landfill, Incinerator (Industrial) Landfill, Incinerator (Medical) Landfill, Industrial Landfill, Land Clearing and Inert Debris Landfill, Mixed Waste Processing Landfill, Municipal Solid Waste Landfill, Tire Treatment and Processing Landfill, and Transfer and Processing Stations. State/Tribal LUST: NCDENR INCIDENT MANAGEMENT DATA (UST and Groundwater) - database of leaking underground storage tanks. This database is a subset of the Incident Management Data (UST and Groundwater) where the source is a leaking ust. This data is concerned with petroleum storage systems and includes facilities and/or locations that have reported the possible release of contaminants. This database also includes State Spill Sites. REGIONAL UST DATABASE (SUBSET) - database of information obtained from the Regional Offices in which an incident has occurred. It provides a more detailed explanation of current and historic activity for individual sites, as well as what was previously found in the Incident Management Database. State/Tribal UST/AST: NCDENR/EPA REGISTERED TANKS and FACILITY DATABASE - database of underground storage tanks registered with the North Carolina Department of Environment and Natural Resources. Inclusion on this list indicates the presence of underground petroleum storage tanks and therefore the potential for environmental problems. It does not necessarily indicate existing problems.TRIBAL LAND UNDERGROUND STORAGE TANKS - database of underground storage tanks that are reported to be on Native American lands.REGIONAL UST DATABASE - database of information obtained from the Regional Offices. It provides a more detailed explanation of current and historic activity for individual sites, as well as what was previously found in the Incident Management Database. State/Tribal IC: NCDENR STATE INACTIVE HAZARDOUS SITES LIST SUBSET - database of sites and Facilities that have land use restrictions and are being investigated due to reported releases of Hazardous substances. Included within this Inactive Hazardous Waste Sites Inventory database are the following classifications: Inactive Hazardous Waste Sites (IHS), No Further Action Sites (NFA), Duplicate Sites (DS), Inactive Hazardous Waste Sites Priority List Sites (SPL) State/Tribal VCP: NCDENR STATE INACTIVE HAZARDOUS SITES LIST SUBSET- database of sites and Facilities that are being investigated due to reported releases of Hazardous substances and have a voluntary cleanup aggreement. Included within this Inactive Hazardous Waste Sites Inventory database are the following classifications: Inactive Hazardous Waste Sites (IHS), No Further Action Sites (NFA), Duplicate Sites (DS), Inactive Hazardous Waste Sites Priority List Sites (SPL) State/Tribal Brownfields: NCDENR BROWNFIELD PROJECTS INVENTORY - database of Active Eligible Sites, Projects Pending Eligibility, and Finalized Brownfields Agreements. State Other: NC DENR North Carolina Dry-Cleaning Solvent Cleanup Act Program (DSCA) – Database of certified site list and project managers DENR DRYCLEANING SITES LIST – Database of all sites identified by the department with possible dry-cleaning solvent contamination. List includes sites that have been certified into the DSCA Program. Federal IC / EC: EPA FEDERAL ENGINEERING AND INSTITUTIONAL CONTROLS- Superfund sites that have either an engineering or an institutional control. The data includes the control and the media contaminated. RESOURCE CONSERVATION AND RECOVERY INFORMATION SYSTEM SITES (RCRA) – RCRA site the have institutional controls. Dry Cleaners: NC DENR North Carolina Dry-Cleaning Solvent Cleanup Act Program (DSCA) – Database of certified site list and project managers DENR DRYCLEANING SITES LIST – Database of all sites identified by the department with possible dry-cleaning solvent contamination. List includes sites that have been certified into the DSCA Program. Environmental FirstSearch Database Sources NPL: EPA Environmental Protection Agency Updated quarterly NPL DELISTED: EPA Environmental Protection Agency Updated quarterly CERCLIS: EPA Environmental Protection Agency Updated quarterly NFRAP: EPA Environmental Protection Agency. Updated quarterly RCRA COR ACT: EPA Environmental Protection Agency. Updated quarterly RCRA TSD: EPA Environmental Protection Agency. Updated quarterly RCRA GEN: EPA/MA DEP/CT DEP Environmental Protection Agency, Massachusetts Department of Environmental Protection, Connecticut Department of Environmental Protection Updated quarterly Fed Brownfield: EPA Environmental Protection Agency Updated quarterly ERNS: EPA/NRC Environmental Protection AgencyNational Response Center. Updated annually Tribal Lands: DOI/BIA United States Department of the InteriorBureau of Indian Affairs Updated annually State/Tribal Sites: NCDENR North Carolina Department of Environment and Natural Resources, Division of Waste Management Updated quarterly State Spills 90: NCDENR North Carolina Department of Environment and Natural Resources, Division of Water Quality/Groundwater Section Updated quarterly State/Tribal SWL: NCDENR North Carolina Department of Environment and Natural Resources, Division of Waste Management Updated annually State/Tribal LUST: NCDENR North Carolina Department of Environment and Natural Resources, Division of Water Quality/Groundwater Section Updated quarterly State/Tribal UST/AST: NCDENR/EPA North Carolina Department of Environment and Natural Resources, Division of Waste ManagementEnvironmental Protection Agency Updated quarterly State/Tribal IC: NCDENR North Carolina Department of Environment and Natural Resources, Division of Waste Management Updated quarterly State/Tribal VCP: NCDENR North Carolina Department of Environment and Natural Resources, Division of Waste Management Updated quarterly State/Tribal Brownfields: NCDENR North Carolina Department of Environment and Natural Resources Updated quarterly State Other: NC DENR North Carolina Department of Environment and Natural Resources, Division of Waste Management Updated quarterly Federal IC / EC: EPA Environmental Protection Agency Updated quarterly Dry Cleaners: NC DENR North Carolina Department of Environment and Natural Resources, Division of Waste Management Updated quarterly Environmental FirstSearch Street Name Report for Streets within .25 Mile(s) of Target Property Target Property:3405 S TRYON ST JOB:8606 CHARLOTTE, NC 28217 Street Name Dist/Dir Street Name Dist/Dir Bank St 0.21 NE Blairhill Rd 0.18 SW Clanton Rd 0.09 NW Hartford Ave 0.24 SE Herman Ave 0.15 NE May St 0.11 NE Pelton St 0.13 SE S TRYON ST 0.00-- Saint Vardell Ln 0.25 NW State Hwy 49 0.02 NE Trade Park Ct 0.03 NW Tryclan Dr 0.13 SW Wayne Ave 0.07 NE Environmental FirstSearch 1 Mile Radius ASTM Map: NPL, RCRACOR, STATE Sites 3405 S TRYON ST, CHARLOTTE, NC 28217 Source: Tele Atlas Target Site (Latitude: 35.196858 Longitude: -80.875927) ....................... Identified Site, Multiple Sites, Receptor ..................................................... NPL, DELNPL, Brownfield, Solid Waste Landfill (SWL), Hazardous Waste Triballand..................................................................................................... Black Rings Represent 1/4 Mile Radius;Red Ring Represents 500 ft. Radius Environmental FirstSearch .5 Mile Radius ASTM Map: CERCLIS, RCRATSD, LUST, SWL 3405 S TRYON ST, CHARLOTTE, NC 28217 Source: Tele Atlas Target Site (Latitude: 35.196858 Longitude: -80.875927) ....................... Identified Site, Multiple Sites, Receptor ..................................................... NPL, DELNPL, Brownfield, Solid Waste Landfill (SWL), Hazardous Waste Triballand..................................................................................................... Black Rings Represent 1/4 Mile Radius;Red Ring Represents 500 ft. Radius Environmental FirstSearch .25 Mile Radius ASTM Map: RCRAGEN, ERNS, UST, FED IC/EC, METH LABS 3405 S TRYON ST, CHARLOTTE, NC 28217 Source: Tele Atlas Target Site (Latitude: 35.196858 Longitude: -80.875927) ....................... Identified Site, Multiple Sites, Receptor ..................................................... NPL, DELNPL, Brownfield, Solid Waste Landfill (SWL), Hazardous Waste Triballand..................................................................................................... Black Rings Represent 1/4 Mile Radius;Red Ring Represents 500 ft. Radius Environmental FirstSearch .5 Mile Radius Non-ASTM Map: Spills 90, Spills 80, Brownfield 3405 S TRYON ST, CHARLOTTE, NC 28217 Source: Tele Atlas Target Site (Latitude: 35.196858 Longitude: -80.875927) ....................... Identified Site, Multiple Sites, Receptor ..................................................... NPL, DELNPL, Brownfield, Solid Waste Landfill (SWL), Hazardous Waste Triballand..................................................................................................... National Historic Sites and Landmark Sites ................................................ Black Rings Represent 1/4 Mile Radius;Red Ring Represents 500 ft. Radius SEP_14-2812 1A?L4 AN JUDY SULLIVAN Soptember 10,2012 '784442e304 P-42 t(li.i Andrtly Drivt, Suitt A Wcrr (:hcrter, lA 19380'4291 l€l 610.840,9100 frr 610,t|40.9199 wrvi\,.ildvirncadgeoservi(es.c0tn 2004-1292.15 Ada Shapiro, Trustoo 7804 C Fain iew RD #123 Charlofie, NC 28226 RE: Remedial Activides Satus 3405 South 'Iryon Sroot CharlotlE, North Carolina Dear Mrs. Shapiro: Per your lequest, I have developed thc following infornation tLo summarize tle remediation aotivitiog ar the 200 clanton Road property, which is adjacent to your properry at 340s south rryon stroot. sismensMedical Soltrtions, the former owner of20O clanton Road. hes been performing inveitigation activities in nccordance with an Adminisrrativo Order ofConscnl with tho State of North Caroiina ind the Reqisterrd Environmontal Consultant Progtam sinoe 1999. These activities are ongoing. The remedial investigation identified -soil, sediment and groundwator impacted by the form€r plantop€mtions. ldentified substances of concem inoluded motals, chlorin;ted orginic solvents,'andpolyaromatic hydrocarbons. Thcso impact were both on and off the 200 clanton -noad proporty. Thosoil snd sedimcnt impscts lhat wor? on your propefty wer€ located in the e""ement "lon! y'our iastemproporty boufidary and in the dry creek bed along our southwestern property boundary. Th'e'remediationfor these soils aud sediments was completed in 2008, The soi) and sediments were excavated Ioresidential standsrds ald the material taken for disposal at a local landfill. Groundwater beneath the 200 clanto' Road propeft)- and your propcny is impacted with chlorinatedorqdnic. solvents (primarily trichloroethen6) and assoaialod bicdegradation breakdorvn compounds(primarily 1,2-dichloroeth6oe and vinyl ohloride). The on-site sources of groundwater contaminationhave resulted in the migration of dissorvod concontrations onto your properfy. siemons has beenperforming activc temediation ofth€ source areas ou-site since 2005. TheRemeiial Action plan foi tho200 Clantofl Road property calls for grourrdwater source troatment on-site. This on_sitg troatment isanticipaEd to generate a natural rcmediarion ofthe lowor concontrations on your properlv. To date, thePhase I snd Ph8.eo [I groundwater. remediation.hare been relatively suooossfui in significantly reducingthe on-sitc oontaminant concentration$. A third phase ofon-site romediarion is planied fo, *,. rrrsi trarof 2013. currently, the groundwater wclls on yo.ur property arong south rryon stroot and your westem prop€nyboundary hsve concotrtrations slightly above oi less thar-the srate's irinking water sundardr. etJng J;u,*^r:tm, prop:ry- l:undary, higher conc€ntrations are present. These higher concentrations are thJflcusot the ptann6d 2013 Foundwdter remedintion on the 200 Clanton Road piopeny. ln addition' in october 2012, five (5) deep soil gas sampres wero oolrected on your prop€rty per new stato Fui91nc6 tg evaluete the potential for uapors irom thi groundwater to mrgrate upwards and into vourbuilding. Two of the locations were next to your buildirig on the oastem "ia .*i'rr". riarr. ii. ir.,""(3) samples collectod rvore located in the eastem portion of your propeny where the higher groundwater f \t djdrp(rod\2ooa,2y2.P.t6n Cr$c tch{dtd Aertdn\S* fiLdcoeunnrisr\A.nldriidn Aahhlar Sutrrsrr {oci sEP- 14-2A 12 1E:15 Ail JUITY SULL I VAN '7944424=84 P. S3 Ada Shapiro, Trustet 2004-lan-rs Septemb$ I0, 20|2 Page 2 of2 ooncentrations ara looated. Two additional locations wore sttompt€d but thc samplas could not be collmted since tbe soils were very tight. All five (5) soil gas ramples w€re b€low thc stato's industriaUcommgrcial vapor inEusion screening lovels. Thereforc, no ftrrthor agtions were wafrantod or r6quirod, I hope this suftmary infomdtion sufficiently explaine thc historic snd ongoing remedial aotivitiog at the 200 Clanton Road property and related activitics on your propeny. In thc future we will need continu€d access to the moniloringwells on your proporly, Plcase do not h€Bitato !o contact mc with any questions. Sinoorely, ADVANCED CEOSERVICES SWK:vm sc: Robert Friodman, Siomens Stephefi W. KirsohniflP.E. F:\tldacdae4rmal292.f.l6i Cto. &$.dn ld.lvt .'l'd\Co'8hi!.rho4trE dirriq A.r,vita* Sur.uy.ds APPENDIX IV HISTORICAL RESEARCH DOCUMENTATION APPENDIX V SITE PHOTOGRAPHS PHOTOGRAPHS Photograph No. 1 View of the subject site. Photograph No. 2 View of the subject site. PHOTOGRAPHS Photograph No. 3 View of the showroom and offices. Photograph No. 4 View of the production area. PHOTOGRAPHS Photograph No. 5 View of the production area. Photograph No. 6 View of various paint containers. PHOTOGRAPHS Photograph No. 7 View of the ink storage room. Photograph No. 8 View of the wash basin and floor drain. PHOTOGRAPHS Photograph No. 9 View of one air compressor. Photograph No. 10 View of the second air compressor. PHOTOGRAPHS Photograph No. 11 Typical view of the monitoring wells on-site. Photograph No. 12 View of the creek on the southern property boundary. PHOTOGRAPHS Photograph No. 13 View of the natural gas connection. Photograph No. 14 View of the pad mounted transformer. APPENDIX VI STATEMENT OF QUALIFICATIONS plf David E. Valentine Staff Environmental Technician EDUCATION Bachelor of Science, 2011, Natural Resources The University of the South Sewanee, Tennessee Mr. Valentine is a Staff Environmental Technician for ECS, Carolinas, LLP. Mr. Valentine is primarily responsible for conducting environmental site assessments. ENVIRONMENTAL ASSESSMENT -Mr. Valentine has performed numerous Phase I Environmental Site Assessments (ESAs)to determine environmental liabilities for commercial, residential, institutional, industrial and retail facilities. He has performed environmental assessments in North Carolina and South Carolina. He has experience performing preliminary ESAs to evaluate on-site and off-site concerns that may impact the site. His scope of work typically includes performance of an on-site and off- site reconnaissance, reviewing regulatory lists, obtaining and reviewing aerial photographs, topographic maps, Sanborn Fire Insurance Maps, city directories, and other published information. PHASE II ENVIRONMENTAL SITE ASSESSMENT -Mr. Valentine has assisted with field activities for Phase II Environmental Site Assessments (ESAs)including both soil and groundwater investigations. Types of assessments include leaking underground storage tanks (USTs), oil and hazardous material spills or releases. On-site activities include locating and drilling soil borings, collecting and screening soil samples, installing monitoring wells and collecting groundwater samples. UNDERGROUND STORAGE TANKS -Mr. Valentine has assisted with several UST assessments and removals including collecting samples and monitoring field activities. He has performed several risk-based assessments including Limited Site Assessments (LSAs). He has monitored field activities and collected samples during removal of petroleum contaminated soils. SAMPLE PROJECT EXPERIENCE ·Skybrook Village, Huntersville, NC ·RW Garcia Building, Lincolnton, NC ·Charlotte Medical Office Building, Charlotte, NC ·Hartsville Apartments, Hartsville, SC ·Charter School, Mooresville, NC ·Westgate Industrial Site, Clover, SC ·Southcross Industrial Center, Rock Hill, SC ·International Corporate Center, Concord, NC ·Circle at Southend, Charlotte, NC ·Crossland Dental, Mount Pleasant, SC plf Brian E. Maas REM Director of Environmental Services EDUCATION  Bachelor of Science, Resource Management, 1986,  College of Environmental Science and Forestry,  Syracuse University, Syracuse, NY  Associates of Applied Science, 1984, SUNY Ranger  School, Wanakena, NY  REGISTRATIONS/CERTIFICATIONS  Registered Environmental Manager (REM); Asbestos  Inspector: NC, SC, TN, & VA; Asbestos  Management Planner: NC, SC, TN, & VA; Asbestos  Abatement Designer: NC, TN, & VA; Inspector/Risk  Assessor: NC; Certified Mold Remediator – Indoor  Air Quality Association; OSHA 40 Hour and 8 Hour  Training  Mr. Maas is the Director of Environmental Services  for ECS Carolinas, LLP and assists with business  development, marketing, technical oversight and  coordination of environmental services for 13  branches of ECS throughout North Carolina and  South Carolina. Mr. Maas has been performing  environmental consulting work for 20 years and has  worked with ECS for 15 years. His specialties include  transactional environmental services (Phase I ESAs,  Phase II and Phase III ESAs), Brownfields  assessments, remediation and redevelopment, mold,  asbestos, lead‐based paint, indoor air quality and  wetland services.      NATURAL RESOURCES SERVICES ‐ Mr. Maas has  experience in consulting with clients and performing  wetland identification, delineation, U.S. Army Corp.  of Engineers verification. He has experience in  delineating different varieties of wetland ecosystems  and has experience with Federal and State permitting  requirements and regulations. Additionally, Mr. Maas       has experience in performing endangered species  assessments, natural resource investigations, and  stream and riparian area restoration and mitigation.    PHASE 1, FCC/NEPA AND PHASE II ENVIRONMENTAL  ASSESSMENTS ‐ Mr. Maas has performed over 1,000  Phase I, FCC/NEPA, and Phase II environmental  assessments to determine environmental liabilities  for Real Property Transfers. He has performed  environmental liability assessments in North  Carolina, South Carolina, Virginia, West Virginia,  Alabama, Tennessee, Utah, Ohio and New York.    ENVIRONMENTAL SITE ASSESSMENTS ‐ Mr. Maas has  managed numerous phase II environmental site  assessments including both soil and groundwater  investigations. Types of assessments include leaking  underground storage tanks (USTs), oil and hazardous  material spills, and wastewater discharges. On‐site  activities include locating and drilling soil borings,  collecting and screening soil samples, installing  monitoring wells and collecting groundwater  samples. Mr. Maas uses the data collected from soil  and groundwater sample analyses to determine the  area impacted and to recommend further  assessment or remediation activities, if necessary.      Place picture  here.  The size  should be 2.06 x  163 or cover the  blue box