Loading...
HomeMy WebLinkAbout26093_Dynamic Auto II_Final EMP+Appendice_20240112 1 EMP Version 3, March 2023 I. NORTH CAROLINA BROWNFIELDS REDEVELOPMENT SECTION II. ENVIRONMENTAL MANAGEMENT PLAN This form is to be used to prepare an Environmental Management Plan (EMP) for projects in the North Carolina Brownfields Redevelopment Section at the direction of a Brownfields project manager. The EMP is a standard requirement of a Brownfields Agreement (BFA). Its purpose is to clarify actions to be taken during demolition and construction at Brownfields properties in an effort to avoid delays in the event of the discovery of new contamination sources or other environmental conditions. The EMP provides a means to document redevelopment plans and environmental data for each applicable environmental medium to inform regulatory-compliant decision-making at the site. As much detail as possible should be included in the EMP, including contingency planning for unknowns. Consult your project manager if you have questions. Prospective Developers and/or their consultants must complete and submit this form and all pertinent attachments, see checklist below, to their Brownfields project manager prior to any earthmoving or other development-related activities that have the potential to disturb soil at the Brownfields Property, including demolition. For the EMP to be valid for use, it must be completed, reviewed by the Section, signed by all parties working on the project, and approved by the Brownfields project manager. Failure to comply with the requirements of the EMP could jeopardize project eligibility, or in the event of a recorded agreement, be cause for a reopener. The EMP is valid only for the scope of work described herein and must be updated to be applicable for new phases of redevelopment or after significant changes in applicable regulatory guidance. Risk characterization of a Brownfields Property to DEQ’s written satisfaction is required prior to EMP approval. Voluntary Metrics Tab The NC Brownfields Redevelopment Section updates estimated capital investment (from the Brownfields Property Application) and estimated jobs created (from the Brownfields Agreement) whenever possible. As a voluntary measure, you may opt to complete the below information for capital investment and jobs created as estimated by your final redevelopment plans for the Brownfields Property: 1. Estimated capital investment in redevelopment project: $174 million 2. Estimated jobs created: a. Construction Jobs: 1,000 b. Full Time Post-Redevelopment Jobs: 200 2 EMP Version 3, March 2023 III. Table of Contents NORTH CAROLINA BROWNFIELDS REDEVELOPMENT SECTION .................................................................. 1 ENVIRONMENTAL MANAGEMENT PLAN .................................................................................................... 1 GENERAL INFORMATION ........................................................................................................................ 4 COMMUNICATIONS ................................................................................................................................ 4 NOTIFICATIONS TO THE BROWNFIELDS REDEVELOPMENT SECTION ..................................................... 5 REDEVELOPMENT PLANS ........................................................................................................................ 6 CONTAMINATED MEDIA ......................................................................................................................... 8 PART 1. SOIL ........................................................................................................................................ 8 PART 2. GROUNDWATER .................................................................................................................. 22 PART 3. SURFACE WATER .................................................................................................................. 24 PART 4. SEDIMENT ............................................................................................................................ 25 PART 5. SOIL VAPOR ......................................................................................................................... 25 PART 6. INDOOR AIR ......................................................................................................................... 26 VAPOR INTRUSION MITIGATION SYSTEM ............................................................................................. 27 CONTINGENCY PLAN ............................................................................................................................. 28 POST-REDEVELOPMENT REPORTING..................................................................................................... 30 APPROVAL SIGNATURES ....................................................................................................................... 31 3 EMP Version 3, March 2023 So that the EMP provides value in protecting Brownfields eligibility and public health, the preparer shall ensure that the following steps have been completed prior to submitting the EMP for review. Any EMP prepared without completing all of the following is premature and may be returned without comment. ☒ Site sampling and assessment that meets Brownfields’ objectives is complete and has been reviewed and approved by the Brownfields project manager. ☒ Specific redevelopment plans, even if conceptual, have been developed for the project, submitted and reviewed by the Brownfields project manager. Please submit, along with the completed EMP form, the following attachments, as relevant and applicable to the proposed redevelopment: ☒ A set of redevelopment plans, including architectural/engineering plans, if available; if not, conceptual plans may suffice if updated when detailed plans are drafted. (Att. 1.0) ☒ A figure overlaying redevelopment plans on a map of the extent of contamination for each media. (Att. 2.0, 2.1, 2.3, 2.4, 2.5, and 2.6) ☒ Site grading plans that include a cut and fill analysis. (Att. 3.0 and 3.1) ☐ A figure showing the proposed location and depth of impacted soil that would remain onsite after construction grading. ☒ Any necessary permits for redevelopment (i.e. demolition, etc.). (Att. 4.0) ☒ A detailed construction schedule that includes timing and phases of construction. (Att. 5.0) ☒ Tabulated data summaries for each impacted media (i.e. soil, groundwater, soil gas, etc.) applicable to the proposed redevelopment. (Att. 2.2, 6.0, 6.1, 6.2, 6.3, 6.4, and 7.0) ☒ Figures with the sampling locations and contamination extents for each impacted media applicable to the proposed redevelopment. (Att. 2.0, 2.1, 2.3, 2.4, 2.5, and 2.6) ☐ A full final grade sampling and analysis plan, if the redevelopment plan is final. ☐ If known, information about each proposed potential borrow soil source, such as aerial photos, historic site maps, historic Sanborn maps, a site history, necessary for Brownfields approval. ☐ Information and, analytical data if required, for quarries, or other borrow sources, 4 EMP Version 3, March 2023 detailing the type of material proposed for import to the Brownfields Property. ☐ A work plan for the sampling and analysis of soil to be brought onto the Brownfields Property. Refer to Issue Resolution 15 in Brownfields Redevelopment Section Guidelines. ☒ A map of the Brownfields Property showing the location of soils proposed for export and sampling data from those areas. (Att. 2.0, 2.2, and 6.0) ☒ If a Vapor Intrusion Mitigation System (VIMS) is required by the Brownfields Redevelopment Section, the VIMS plan will be signed and sealed by a NC Professional Engineer. The VIMS Plan may also be submitted under separate cover. GENERAL INFORMATION Date: 10/16/2023 Revision Date (if applicable): 12/21/2023 Brownfields Assigned Project Name: Dynamic Auto Works II (primary redevelopment) and Foundry Brownfields Project Number: 26093-22-060 (primary redevelopment) and 17021-13-060 Brownfields Property Address: 600 Eldridge Street, Charlotte, NC 28202, a portion of Parcel 07318201, and “Stonewall Alley” (primary redevelopment) and Foundry (619 & 623 S Cedar Street) Brownfields Property Area (acres): The Dynamic Auto Works II property is approximately 1.5 acres and the proposed development is anticipated to disturb approximately 0.9 acres. The Foundry property is an adjoining parcel of approximately 3.5 acres and the Dynamic Auto Works II development is anticipated to encroach on approximately 1.6 acres. The redevelopment will span both properties. Combined, this EMP has been prepared for both Dynamic Auto Works II and Foundry properties. A site map is provided in Attachment 2.0. Is Brownfields Property Subject to RCRA Permit?.......................☐ Yes ☒ No If yes enter Permit No.: Click or tap here to enter text. Is Brownfields Property Subject to a Solid Waste Permit….……..☐ Yes ☒ No If yes, enter Permit No.: Click or tap here to enter text. COMMUNICATIONS A copy of this EMP shall be distributed to all the parties below as well as any contractors or site workers that may be exposed to site vapors, soil, groundwater, and/or surface water. Additionally, a copy of the EMP shall be maintained at the Brownfields Property during redevelopment activities in an area that is prominently accessible to site workers. NOTE, THE EMP DOES NOT TAKE THE PLACE OF A SITE-SPECIFIC HEALTH AND SAFETY PLAN. Prospective Developer (PD): AP Foundry, LP 5 EMP Version 3, March 2023 Contact Person: Welch Liles Phone Numbers: Office: 704-423-1660 Mobile: Click or tap here to enter text. Email: wliles@asanapartners.com Contractor for PD: Mill Creek Residential Contact Person: Justin Houston Phone Numbers: Office: 704-565-0835 Mobile: Click or tap here to enter text. Email: jhouston@MCRTrust.com Environmental Consultant: ONE Environmental Group of Carolina, PLLC Contact Person: Jenny Tang Phone Numbers: Office: 301-787-2690 Mobile: Click or tap here to enter text. Email: jtang@oneenv.com Brownfields Redevelopment Section Project Manager: Carolyn Minnich Phone Numbers: Office: 704-661-0330 Mobile: Click or tap here to enter text. Email: Carolyn.minnich@deq.nc.gov Other DEQ Program Contacts (if applicable, i.e., UST Section, Inactive Hazardous Site Branch, Hazardous Waste, Solid Waste): Click or tap here to enter text. NOTIFICATIONS TO THE BROWNFIELDS REDEVELOPMENT SECTION Written advance Notification Times to Brownfields project manager: Check each box to accept minimum advance notice periods (in calendar days) for each type of onsite task: On-site assessment or remedial activities:……………………………………….…… 10 days Prior ☒ Construction or grading start:……………………………………….………………………. 10 days Prior ☒ Discovery of stained soil, odors, USTs, buried drums or waste, landfill, or other signs of previously unknown contamination: ……………………………….……………………………………. Within 48 hours ☒ Implementation of emergency actions (e.g. dewatering, flood or soil erosion control measures in area of contamination, ventilation of work zones):…………….……….……… Within 48 hours ☒ Installation of mitigation systems:………………………….………………….……….. 10 days Prior ☒ Other notifications as required by local, state or federal agencies to implement redevelopment activities: (as applicable): ……………………….…………………………………………..… Within 30 days ☒ 6 EMP Version 3, March 2023 REDEVELOPMENT PLANS 1) Type of Redevelopment (check all that apply): ☒Residential ☐Townhomes (Prior written DEQ approval REQUIRED regardless of ownership structure) ☐Recreational ☐Institutional ☒Commercial ☐Office ☒Retail ☐Industrial ☐Other specify: Proposed redevelopment plans include razing a portion of the existing site buildings and constructing a new multi-tenant commercial retail building with an associated parking deck and high-density residences above. The redevelopment plans are provided as Attachment 1.0. The structures located at 623 S Cedar Street and 600 Eldridge Street will be demolished. The structures located at 601 and 619 S Cedar Street will continue to be used in their present state. The redevelopment will include a ground-level 2-story commercial retail space, located plan west, with 3 stories of residential apartments above. Adjoining this structure due plan south will be a ground-level 2-story space to include a leasing office, clubhouse, residential lobby, storage, mechanical/utility rooms, commercial retail space, and retail lobby. Residential apartments and portions of the parking deck will be located on levels 3-5 above the retail space and residential amenity areas. A 5-story parking deck will be a part of this structure located along the plan south of the redevelopment. Two (2) additional multi-family residential buildings will begin on level 6, constructed above the parking deck & retail/amenity space (levels 1-2), and residential space (levels 3-5). 2) Check the following activities that will be conducted prior to commencing earth-moving activities at the site: ☒ Review of historic maps (Sanborn Maps, facility maps) ☒ Conducting geophysical surveys to evaluate the location of suspect UST, fuel lines, utility lines, etc. ☒ Interviews with employees/former employees/facility managers/neighbors 3) Summary of Redevelopment Plans (MANDATORY: attach detailed plans or conceptual plans, if detailed plans are not available. EMP review without such information would be premature): Provide brief summary of redevelopment plans, including demolition, removal of building slabs/pavement, grading plans and planned construction of new structures: A copy of the most recent redevelopment plans is included in Attachment 1.0. Copies of the cut- fill analysis and grading plan are included in Attachments 3.0 and 3.1. Redevelopment plans include razing a portion of the existing site buildings and constructing a new multi-tenant commercial retail building with an associated parking deck and high-density residences above. The structures located at 623 S Cedar Street and 600 Eldridge Street will be demolished. The structures located at 601 and 619 S Cedar Street will continue to be used in their present state. Redevelopment activities also include the construction of access drives and landscaped areas. The building located along plan west of the redevelopment consists of a ground-level 2-story 7 EMP Version 3, March 2023 commercial retail space. Soil from zones EX-0 through EX-2 will be excavated to construct the foundations of this structure. Multi-family residential will start on level 3 and extend up to level 5. All ground contact space is two stories in height. A cumulative total of 20,000 sq ft of occupiable space is located on the ground floor. The space will consist of open retail space and service corridors. An open-air, mechanically vented parking deck is located along the plan south of the redevelopment. Adjoining the parking deck will be a cumulative 18,800 sq ft of occupiable space on the ground floor located along the plan north of the parking deck. Soil from zones EX-3 through EX-13 will be excavated to construct the foundations of this structure. The occupiable space will consist of a leasing office, clubhouse, residential lobby, storage, mechanical/utility rooms, commercial retail space, and retail lobby. All ground contact space is two stories in height. Residential units and portions of the parking deck will be located on levels 3-5 above the retail space and residential amenity areas. Two (2) additional buildings will begin on level 6, constructed above the parking deck & retail/amenity space (levels 1-2), and residential space (levels 3-5). The space will consist of multi-family residential. 4) Do plans include demolition of structure(s)?: ☒ Yes ☐ No ☐ Unknown ☒ If yes, please check here to confirm that demolition will be conducted in accordance with applicable legal requirements, including without limitation those related to lead and asbestos abatement that are administered by the Health Hazards Control Unit within the Division of Public Health of the North Carolina Department of Health and Human Services. If available, please provide a copy of your demolition permit. 5) Are sediment and erosion control measures required by federal, state, or local regulations? S&EC requirements can be found at: https://deq.nc.gov/about/divisions/energy-mineral-and-land- resources/erosion-and-sediment-control/erosion-and-sediment-control-laws-and-rules ☒ Yes ☐ No ☐ Unknown ☒ If yes, please check here to confirm that earth-work will be conducted in accordance with applicable legal requirements. If soil disturbance is necessary to install sediment and erosion control measures, they may not begin until this EMP is approved. 6) Which category of risk-based screening level is used or is anticipated to be specified in the Brownfields Agreement? Note: If children frequent the property, residential screening levels shall be cited in the Brownfields Agreement for comparison purposes. ☒ Residential ☐ Non-Residential or Industrial/Commercial 7) Schedule for Redevelopment (attach construction schedule): a) Construction start date: 1/1/2024 b) Anticipated duration (specify activities during each phase): 8 EMP Version 3, March 2023 Site work and demolition of the existing site buildings are projected to begin in January 2024. The redevelopment is expected to be completed and structures occupied in November 2026. A copy of the preliminary construction schedule is provided in Attachment 5.0. c) Additional phases planned? ☐ Yes ☒ No If yes, specify the start date and/or activities if known: Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. Start Date: Click or tap to enter a date. Planned Activity: Click or tap here to enter text. d) Provide the planned date of occupancy for new buildings: 11/1/2026 CONTAMINATED MEDIA Please fill out the sections below, using detailed site plans, if available, or estimate using known areas of contaminated soil and a conceptual redevelopment plan. Provide a figure overlaying new construction onto figure showing contaminated soil and groundwater locations. 1) Contaminated Media on the Brownfields Property Part 1. Soil: ☒ Yes ☐ No ☐ Suspected ☐ Unknown Part 2. Groundwater: .................................... ☒ Yes ☐ No ☐ Suspected ☐ Unknown Part 3. Surface Water: ☐ Yes ☒ No ☐ Suspected ☐ Unknown ☐ N/A Part 4. Sediment: .......................................... ☐ Yes ☒ No ☐ Suspected ☐ Unknown ☐ N/A Part 5. Soil Vapor: ......................................... ☒ Yes ☐ No ☐ Suspected ☐ Unknown Part 6. Sub-Slab Soil Vapor: .......................... ☒ Yes ☐ No ☐ Suspected ☐ Unknown Part 7. Indoor Air: ......................................... ☐ Yes ☐ No ☐ Suspected ☒ Unknown 2) For the Area of Proposed Redevelopment on the Brownfields Property, attach tabulated data summaries for each impacted media and figure(s) with sample locations. PART 1. SOIL 1) Known or suspected contaminants in soil (list general groups of contaminants): ONE conducted soil assessment activities in April 2023 to characterize site soils and to 9 EMP Version 3, March 2023 determine proper soil disposal procedures before grading activities begin. ONE divided the site into fourteen (14) in situ soil characterization sections (EX-0 through EX-13) based on the proposed excavation depths and anticipated bedrock. In each soil characterization section, a set of three (3) (A through C) or five (5) (A through E) soil borings were advanced to pre-determined excavation depths or until drill rig refusal. Additionally, two (2) soil borings (SB-1 and SB-2) were advanced to a depth of approximately 2 ft bgs in the interior and exterior of the former Dynamic Auto Works building to evaluate for shallow impacts by the former auto repair facility. In total, 53 soil samples were submitted for laboratory analysis. In situ soil characterization sections EX- 0, EX-1, EX-2, EX-3, EX-9, and EX-10 were located on the Foundry property. All other in situ soil characterization sections were located on the Dynamic Auto Works II property. A Sample Location Map is included in Attachment 2.0. It should be noted that excavation zone EX-0 is depicted on the sample location map; however, no soil samples were collected based on the available soil analytical data from 2013 as further discussed below. Soil analytical results were compared to the North Carolina Department of Environmental Quality (NCDEQ) Preliminary Soil Remediation Goals (PSRGs) and Protection of Groundwater (POG) standards dated January 2023. Additionally, metal concentrations were compared to The Rule of 20 Values derived from the United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP) Maximum Concentration of Contaminants for Toxicity Characteristic, dated November 2004, metals concentrations of Tarmac Virginia Brownfields Property (Tarmac Virginia) (Brownfields Project No. 26067-22-060), and background ranges established for Old 27 Land Clearing and Inert Debris (LCID) and Griffin Farms LCID landfills to assist in off-site disposal. A tabular summary of the soil sample analytical data is included in Attachment 6.0. Soil sample locations and characterization sections are included in Attachment 2.0. A summary of the soil assessment results is provided below: Volatile Organic Compounds (VOCs) Laboratory analytical results reported low detections of VOCs across the site and at estimated laboratory values denoted by a “J”. All detections were below Residential and POG PSRGs. It should be noted that acetone was detected in all samples; however, is a common laboratory contaminant and not a constituent of concern at the site. Semi-Volatile Organic Compounds (SVOCs) Laboratory analytical results reported low detections of SVOCs across the site, predominantly in the shallow 0-2’ intervals and at estimated laboratory values denoted by a “J”. Benzo(a)pyrene was detected in zones EX-8, EX-9, EX-10, and EX-11 at concentrations up to 0.612 milligrams per kilogram (mg/kg) which exceeds the Residential PSRG of 0.11 mg/kg and the Protection of Groundwater (POG) PSRG of 0.12 mg/kg. Detections of 1-methylnaphthalene and naphthalene were also reported above the POG PSRG in zone EX-8 with concentrations of 0.419 mg/kg and 0.489 mg/kg, respectively. Benzo(a)anthracene was detected in zone EX-10 at 0.578 mg/kg which is above the POG PSRG of 0.35 mg/kg. No other volatile compounds were detected above a screening criterion. 10 EMP Version 3, March 2023 Environmental Assessments & Consulting, Inc. (EAC) conducted soil assessment activities in April 2013. Soil sample GP-2 was collected within the footprint of the newly proposed development and is denoted by a pink-colored circle in zone EX-0 of Attachment 2.0. A historical sample location map is included in Attachment 2.1 for reference. Petroleum compounds were detected in the soil sample at estimated laboratory values denoted by a “J”. A tabular summary of historical soil sample analytical data is included in Attachment 6.1. Benzo(a)anthracene was detected at concentrations up to 3.2 mg/kg, which exceeds the POG PSRG and Residential PSRG of 0.35 mg/kg and 1.1 mg/kg, respectively. Benzo(b)fluoranthene was detected at concentrations up to 5.1 mg/kg, which exceeds the POG PSRG and Residential PSRG of 1.2 mg/kg and 1.1 mg/kg, respectively. Indeno(123-cd)pyrene was detected at concentrations up to 3.6 mg/kg, which exceeds the Residential PSRG of 1.1 mg/kg. No other volatile compounds were detected above a screening criterion. Metals RCRA metals arsenic, chromium, hexavalent chromium, mercury, and selenium were detected at concentrations ranging above the POG, Residential, and/or Industrial/Commercial PSRGs. - Arsenic was detected in all samples collected at the site. 36 samples reported concentrations above the Residential PSRG of 0.68 mg/kg. Seven (7) samples reported concentrations above the Industrial/Commercial PSRG of 3.0 mg/kg. One (1) sample reported a concentration above the POG PSRG of 5.8 mg/kg. Concentrations ranged between 0.326 mg/kg to 21.7 mg/kg which is consistent with published background concentrations of the area and did not warrant additional TCLP analysis. - Mercury was detected sporadically across the site in 28 samples. Two (2) samples reported concentrations above the Residential PSRG of 2.3 mg/kg and POG PSRG of 1.0 mg/kg in zones EX-5 and EX-11. Most mercury detections at the site ranged between 0.0286 mg/kg to 0.145 mg/kg which is consistent with the published background concentrations of the area. Eight (8) samples reported concentrations that were above background concentrations ranging from 0.207 mg/kg to 2.79 mg/kg. The mercury concentrations did not warrant additional TCLP analysis. - Selenium was detected in all samples collected at the site. Two (2) samples from zones EX-2 and EX-4 reported concentrations above the POG PSRG of 2.1 mg/kg. Most selenium detections at the site ranged between 0.259 mg/kg to 1.61 mg/kg which is consistent with the published background concentrations of the area. One (1) sample reported a concentration that was above background concentrations at 5.4 mg/kg. Additional TCLP analysis was not warranted. - Hexavalent chromium was detected sporadically across the site in 21 samples. One (1) sample in zone EX-2 reported a concentration above the POG PSRG of 3.8 mg/kg. Hexavalent chromium concentrations detected at the site ranged between 0.211 mg/kg to 3.95 mg/kg. - Total chromium was detected in all samples collected at the site. Most total chromium detections at the site ranged between 4.54 mg/kg to 78.6 mg/kg which is consistent with 11 EMP Version 3, March 2023 published background concentrations of the area. Three (3) samples reported concentrations that were above background concentrations in Zone EX-6 and SB-2. These samples were resubmitted for TCLP analysis and returned with total chromium concentrations below the TCLP regulatory screening value of 5.0 mg/L. - Trivalent chromium was calculated to be detected in all samples collected at the site by subtracting hexavalent chromium from total chromium. Most trivalent chromium detections at the site ranged between 4.54 mg/kg to 77.5 mg/kg which is consistent with published background concentrations of the area. Three (3) samples reported concentrations that were above background concentrations in Zone EX-6 and SB-2. These samples were resubmitted for TCLP analysis and returned with total chromium concentrations below the TCLP regulatory screening value of 5.0 mg/L. - Lead was detected in all samples collected at the site. No concentration exceeded the PSRGs. Most lead concentrations detected at the site ranged between 2.85 mg/kg to 38.1 mg/kg which is consistent with published background concentrations. Four (4) samples reported concentrations that were above background concentrations but below the Rule of 20 Value ranging from 65.5 mg/kg to 99.9 mg/kg. Six (6) samples reported concentrations that were above background concentrations and the Rule of 20 Value of 100 mg/kg in zones EX-5, EX-8, EX-9, EX-10, and EX-11. These samples were resubmitted for TCLP analysis and returned with lead concentrations below the TCLP regulatory screening value of 5.0 mg/L. Through inadvertence, TCLP analysis was not performed for one (1) sample, EX-9 (0-2’). Considering that the total lead concentration for EX-9 (0-2’) was 106 mg/kg and only slightly above the Rule of 20 Value of 100 mg/kg, the sample result was discussed with the laboratory, Brownfields, and Republic. The highest lead concentration detected at the site was 197 mg/kg with a TCLP analysis result of 0.041 mg/L. Based on the results of the remaining TCLP analyses demonstrating concentrations significantly below the TCLP regulatory screening level, this sample does not exhibit a risk of significant hazardous toxicity. 2) Depth of known or suspected contaminants (feet): The soil assessment activities conducted by EAC in April 2013 detected petroleum compounds in soil sample GP-2 at depths up to 6 ft bgs. Benzo(a)anthracene and benzo(b)fluoranthene were detected above the Residential PSRG and POG PSRG. Indeno(123-cd)pyrene was detected above the Residential PSRG. During soil assessment activities conducted by ONE in April 2023, benzo(a)pyrene was detected above the Residential and POG PSRG in four (4) in situ soil characterization sections, EX-8 through EX-11, at depths up to 10 ft bgs. Benzo(a)anthracene was detected above the POG PSRG in situ soil characterization section EX-10 at 2 to 5 ft bgs. 1-methylnaphthalene and naphthalene were detected above the POG PSRG in situ soil 12 EMP Version 3, March 2023 characterization section EX-8 at 0 to 2 ft bgs. RCRA metals were detected above Residential, Industrial/Commercial, and POG PSRGs and across the site, predominantly in the shallow 0-2’ and 2-5’ intervals. Arsenic, hexavalent chromium, and selenium were detected above PSRGs at depths up to 20 ft bgs. 3) Area of soil disturbed by redevelopment (square feet): Approximately 152,000 square feet of soil will be disturbed for clearing and leveling. A copy of the cut-fill analysis and grading plan are included in Attachment 3.0 and 3.1. 4) Depths of soil to be excavated (feet): Cut depths range from less than 1 ft bgs to approximately 20 ft bgs. Bedrock is anticipated to be encountered at depths beyond 20 ft bgs. 5) Estimated volume of soil (cubic yards) to be excavated (attach grading plan): Based on the grading plans and cut and fill analysis, approximately 51,700 cubic yards of soil will be excavated from the site during the proposed grading and redevelopment activities (Attachments 3.0 and 3.1). 6) Estimated volume of excavated soil (cubic yards) anticipated to be impacted by contaminants: Based on the results of in situ soil characterization assessment activities, approximately 11,050 cubic yards of soil contain compounds reported at concentrations above PSRGs or background metals concentrations of Old 27 and Griffin Farms. 7) Estimated volume of contaminated soil expected to be disposed of offsite, if applicable: Soil expected to be disposed of offsite will be transported to the following preapproved sites. If an alternative receiving site is required, prior DEQ written approval will be obtained. - Griffin Farms LCID landfill (Griffin Farms) located at 4242 Morgan Mill Road in Unionville, North Carolina, - Old 27 LCID landfill (Old 27) located at 120 Tate Street in Mount Holly, North Carolina, - Tarmac Virginia Brownfields Property (Tarmac Virginia) (Brownfields Project No. 26067- 22-060) located at 3934 Raleigh Street in Charlotte, North Carolina, - Republic Services RCRA Subtitle D Landfill (Republic) located at 5105 A Morehead Road in Concord, North Carolina. Approximately 31,900 cubic yards of soil with compounds within acceptable metals background ranges will be transported to Griffin Farms, Old 27, Tarmac Virginia, or Republic. Approximately 8,750 cubic yards of soil contain compounds reported at concentrations above the acceptable metals background range of Griffin Farms. This volume of soil will be transported to Old 27, Tarmac Virginia, or Republic. Approximately 9,850 cubic yards of soil contain compounds reported at concentrations above the acceptable metals background range of Griffin Farms and Old 27. This volume of soil will be transported to Tarmac Virginia or Republic. Approximately 1,200 cubic yards of soil contain SVOC compounds reported at concentrations above the 13 EMP Version 3, March 2023 Residential PSRG and/or POG PSRG. This volume of soil will be transported to Republic. PART 1.A. MANAGING ONSITE SOIL If soil is anticipated to be excavated from the Brownfield Property, relocated on the Brownfields Property, or otherwise disturbed during site grading or other redevelopment activities, please provide a grading plan that clearly illustrates areas of cut and fill (approximate areas & volumes are acceptable, if only preliminary data available). 1) HAZARDOUS WASTE DETERMINATION: a) Does the soil contain a LISTED WASTE as defined in the North Carolina Hazardous Waste Section under 40 CFR Part 261.31-261.35?....................................... ☐Yes ☒No ☐ If yes, explain why below, including the level of knowledge regarding processes generating the waste (include pertinent analytical results as needed). Click or tap here to enter text. ☐ If yes, do the soils exceed the “Contained-Out” levels in Attachment 1 of the North Carolina Contained-In Policy?................................................. ☐ Yes ☐ No b) NOTE: IF SOIL MEETS THE DEFINITION OF A LISTED HAZARDOUS WASTE AND EXCEEDS THE CONTAINED-OUT LEVELS IN ATTACHMENT 1 TO THE NORTH CAROLINA CONTAINED-IN POLICY, THE SOIL MAY NOT BE RE-USED ONSITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. c) Does the soil contain a CHARACTERISTIC WASTE?.................................... ☐ Yes ☒ No ☐ If yes, mark reason(s) why below (and include pertinent analytical results). ☐ Ignitability Click or tap here to enter text. ☐ Corrosivity Click or tap here to enter text. ☐ Reactivity Click or tap here to enter text. ☐ Toxicity Click or tap here to enter text. ☐ TCLP results Click or tap here to enter text. ☐ Rule of 20 results (20 times total analytical results for an individual hazardous constituent on TCLP list cannot, by test method, exceed regulatory TCLP standard) Click or tap here to enter text. ☒ If no, explain rationale: Lead was detected in select samples at concentrations greater than the Rule of 20 value of 100 mg/kg. These samples were resubmitted for TCLP analysis and 14 EMP Version 3, March 2023 returned with lead concentrations below the TCLP regulatory screening value of 5.0 mg/L. Based on the results of soil assessment activities and TCLP analysis, no compounds have been identified at characteristically hazardous levels. d) NOTE: IF SOIL MEETS THE DEFINITION OF A CHARACTERISTIC HAZARDOUS WASTE, THE SOIL MAY NOT BE RE-USED ONSITE AND MUST BE DISPOSED OF IN ACCORDANCE WITH DEQ HAZARDOUS WASTE SECTION RULES AND REGULATIONS. 2) Screening criteria by which soil disposition decisions will be made (e.g., left in place, capped in place with low permeability barrier, removed to onsite location and capped, removed offsite): ☒ Preliminary Health-Based Residential SRGs ☒ Preliminary Health-Based Industrial/Commercial SRGs ☒ Division of Waste Management Risk Calculator (For Brownfields Properties Only) ☐ Site-specific risk-based cleanup level. Please provide details of methods used for determination/explanation. Click or tap here to enter text. Additional comments: Click or tap here to enter text. 3) If known impacted soil is proposed to be reused within the Brownfields Property boundary, please check the measures that will be utilized to ensure safe placement and documentation of same. Please attach a proposed location diagram/site map. ☒ Provide documentation of analytical report(s) to Brownfields project manager. ☒ Provide documentation of final location, thickness and depth of relocated soil onsite map to Brownfields project manager once known. ☐ Geotextile to mark depth of fill material. Provide description of material: Click or tap here to enter text. ☒ Manage soil under impervious cap ☒ or clean fill ☒ ☒Describe cap or fill: Documented impacted soils will be covered with an impervious surface (asphalt pavement, sidewalks, buildings, etc.) or covered with a minimum of 2 ft of demonstrably clean fill material. ☒ Confer with NC BF project manager if Brownfield Plat must be revised (or re-recorded if actions are Post-Recordation). ☒ GPS the location and provide site map with final location. ☐ Other. Please provide a description of the measure: Click or tap here to enter text. 15 EMP Version 3, March 2023 4) Please describe the following action(s) to be taken during and following excavation and management of site soils: ☒ Check to confirm that management of fugitive dust from site activities will be handled in accordance with applicable local, state, and federal requirements. Field screening of site soil At a minimum, contractors shall be made aware of protocols should impacted soils (e.g. staining, unusual odors, fill materials) be identified. Describe the field screening method, frequency of field screening, person conducting field screening: During all soil disturbance at the site (excavation and trenching), workers and contractors will observe soil for evidence of potential impacts. Evidence of potentially impacted soil includes a distinct unnatural color, strong odor, or filled or previously disposed materials of potential environmental concern (i.e., chemicals, tanks, drums, etc.). Should the above be observed during site work, the contractor shall stop all work and contact ONE to assess the suspect condition. If ONE confirms that the material may be impacted, then the procedures below will be implemented. In addition, the DEQ Brownfields project manager will be contacted within 48 hours to advise of the condition. Soil sample collection ☐ Yes ☒ Not anticipated - In order to avoid delays in construction, a plan shall be in place for sampling of suspect soils should they be encountered during redevelopment. If soil sample collection is not anticipated but the need to do so is identified during redevelopment, notify the Brownfields project manager of the anticipated sample and report dates for scheduling purposes. Describe the sampling method (e.g., in-situ grab, composite, stockpile, etc.) and confirm that all procedures outlined in applicable DEQ guidance for assessment shall be followed Typically, at least one representative sample (per 500 yd3 for residential and 1,000 yd3 for commercial) consisting of a 3 to 5-point composite sample with grab sample for VOCs based on the highest PID reading is required to determine soil management options: The collection of additional soil samples is not anticipated based on the completed soil characterization activities to date. If impacted soil is encountered during grading and/or installation or removal of utilities, excavation will proceed only as far as needed to allow grading or other construction-related activity to continue and/or only as far as needed to allow alternate corrective measures as described below. Suspect-impacted soil excavated during redevelopment activities that have not been previously characterized may be stockpiled and covered in a secure area to allow construction to progress. Suspect impacted soil will be underlain and covered with a minimum of 10-mil plastic sheeting, following the NCBP Diagram for Temporary 16 EMP Version 3, March 2023 Containment of Impacted or Potentially Impacted Soil. At least one representative soil sample (no less than three aliquot soil samples) at a sample ratio of one soil sample per approximately 1,000 cubic yards of soil will be collected for analyses selected below (i.e., total VOCs, SVOCs, RCRA metals, and hexavalent chromium). The VOC sample will be a grab sample from the aliquot exhibiting the highest PID field screen reading. If the soil sample laboratory analytical results indicate that the soil could potentially exceed the hazardous characteristic criteria based on the Rule of 20, then the soil will also be analyzed by TCLP methods for the compounds that could exceed the hazardous characteristic criteria. Soil will be managed in accordance with the table below. If impacted soil with concentrations above Residential or POG PSRGs is moved to an on-site location, the location and depth will be documented and provided to DEQ. Check applicable chemical analytes for soil samples: ☒ Minimum Sample Requirements: Volatile organic compounds (VOCs) by EPA Method 8260; Semi-volatile organic compounds (SVOCs) by EPA Method 8270; and Metals RCRA List + Hexavalent Chromium by EPA Method 6020/7199 ☐ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Other Constituents & Respective Analytical Method(s) (e.g. Herbicides): Click or tap here to enter text. ☒ Check to confirm that by the owner’s signature and the North Carolina Professional Engineer/Geologist sealing this EMP the consultant understands that no work plan for suspect soil sample collection will be submitted beyond this EMP, and that it is the responsibility of the sealing professional and property owner to ensure that all applicable guidelines and methodologies are followed and reported to DEQ for determination and approval of soil placement prior to final relocation. If impacted soils above applicable PSRGs and/or site specific risk thresholds are proposed to be relocated on-site, prior to final placement on-site, the following shall be submitted for DEQ review/approval - Analytical data that has been sampled in accordance with the above referenced frequency and following procedures outlined in the most recent Brownfields Redevelopment Section Environmental Site Assessment Work Plan Minimum Requirements Checklist (Checklist) and in accordance with DEQ IHSB Guidelines for Assessment and Cleanup of Contaminated Sites (Guidelines) - Figure outlining planned soil placement and any future site features including buildings/hardscape/open areas - A North Carolina PE/PG recommendation of placement 17 EMP Version 3, March 2023 Impacts Options Onsite Placement without conditions Onsite placement under 2 ft of cap or clean fill1, 2 All Constituents below applicable PSRGs X Constituents3 below applicable PSRGs; Metals below background but above PSRGs X Constituents3 below applicable PSRGs; Metals above Background /PSRGs X Constituents above Applicable PSRGs X 1: Requires Prior Written DEQ Approval 2: VOC impacted soils above applicable PSRGs shall not be placed directly beneath building footprints without prior written DEQ approval. 3: Constituents indicate any samples evaluated for other than metals. ☒ Check to confirm that stockpiling of known or suspected impacted soils will be conducted in accordance with Figure 1 of this EMP. Stockpile methodology should provide erosion control, prohibiting contact between surface water/precipitation and contaminated soil, and preventing contaminated runoff. Explain any variances or provide additional details as needed: ☒ Final grade sampling of exposed native soil (i.e., soil that will not be under buildings or permanent hardscape). Select chemical analyses for final grade samples with check boxes below (Check all that apply): ☒ Minimum Sample Requirements: Volatile organic compounds (VOCs) by EPA Method 8260; Semi-volatile organic compounds (SVOCs) by EPA Method 8270; and Metals RCRA List + Hexavalent Chromium by EPA Method 6020/7199 ☐ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Other Constituents & Respective Analytical Method(s) (e.g. Herbicides): Click or tap here to enter text. Please provide a scope of work for final grade sampling, including a diagram of soil sampling locations, number of samples to be collected, and brief sampling methodology. Samples should be collected from 0-2 ft below ground surface, with the exception of VOCs which should be taken from 1-2 ft below ground surface. Alternatively, indicate if a work Click or tap here to enter text. 18 EMP Version 3, March 2023 plan for final grade sampling may be submitted under separate cover. Following completion of soil disturbance for future site development (i.e., after grading and utility construction), ONE will evaluate the site for disturbed areas that will not be covered upon completion of the redevelopment with a minimum of 2 ft of demonstrably clean fill material, landscaping materials, building foundations, sidewalks, asphalt or concrete parking areas, driveways, or other impervious areas (e.g., tightly spaced pavers or bricks). If uncovered disturbed areas with suspected impact exist, a Work Plan will be prepared for final grade sampling for DEQ Brownfields review and approval. ☐ If final grade sampling was NOT selected, please explain rationale: Click or tap here to enter text. PART 1.B. IMPORTED FILL SOIL NO SOIL MAY BE BROUGHT ONTO THE BROWNFIELDS PROPERTY WITHOUT PRIOR APPROVAL FROM THE BROWNFIELDS REDEVELOPMENT SECTION. According to the Brownfields IR 15, “Documenting imported soil (by sampling, analysis, and reporting in accordance with review and written approval in advance by the Brownfields Redevelopment Section), will safeguard the liability protections provided by the brownfields agreement and is in the best interest of the prospective developer/property owner.” Requirements for importing fill: ☒ Check to confirm that the import volumes outlined below have been confirmed based on geotechnical evaluations. 1) Will fill soil be imported to the site?................................................ ☐ Yes ☐ No ☒ Unknown 2) If yes, what is the estimated volume of fill soil to be imported? 3) If yes, what is the anticipated depth that fill soil will be placed at the property? (If a range of depths, list the range.) Click or tap here to enter text. PRIOR TO SOIL PLACEMENT AT THE BROWNFIELDS PROPERTY, a Soil Import Request must be submitted for DEQ Brownfields review and approval. The request shall consist of a data package that details: - Fill source location/history (Phase I if available, current aerials, etc.) - Analytical data that has been sampled in accordance with the below frequency and following procedures outlined in the most recent Brownfields Redevelopment Section Environmental Site Assessment Work Plan Minimum Requirements Checklist (Checklist) and in accordance with DEQ IHSB Guidelines for Assessment and Cleanup of Contaminated Sites (Guidelines) - A table comparing the import soil to existing site concentrations 19 EMP Version 3, March 2023 - A PE/PG recommendation of import - All relevant attachments listed in the Checklist Soil Import Sampling Requirements: Source Sample Frequency Sample Analysis Virgin Material from DEQ Brownfields Pre- approved Quarry None (Contact Brownfields project manager for list of pre- approved Quarries DEQ Permitted Quarry (Not Brownfields Pre- approved) At least one representative sample from area of planned import VOCs, SVOCs, RCRA Metals, any site specific COCs (e.g. pesticides, PCBs, etc.) Other NC DEQ Brownfields Property At least one representative sample per 1,000 yd3 consisting of a 3-point composite sample with grab sample for VOCs based on the highest PID reading VOCs, SVOCs, RCRA Metals, any site specific COCs (e.g. pesticides, PCBs, etc.) Off-site unpermitted/regulated property Bulk Landscape Material from Commercial Vendor (i.e. topsoil) No Sampling Required If other special considerations apply, discuss: Click or tap here to enter text. ☒ Check to confirm that by the owner’s signature and the North Carolina Professional Engineer/Geologist sealing this EMP the consultant understands that no work plan for suspect soil sample collection will be submitted beyond this EMP, and that it is the responsibility of the sealing professional and property owner to ensure that all applicable guidelines are followed and reported in the Soil Import Request for DEQ approval. Failure to meet these requirements could result in resampling and/or failure to approve import. PART 1.C. SOIL EXPORT NO SOIL MAY LEAVE THE BROWNFIELDS PROPERTY WITHOUT APPROVAL FROM THE BROWNFIELDS REDEVELOPMENT SECTION. Failure to obtain approval may violate a brownfields agreement causing a reopener or jeopardizing eligibility in the Section, endangering liability protections and making said action possibly subject to enforcement. Justifications provided below must be approved by the Section in writing prior to completing transport activities. Refer to Brownfields IR 15 for additional details. 1) If export from the Brownfields Property is anticipated, export soil must be sampled at a frequency of one sample per 1,000 yd3 consisting of a 3-point composite sample with a grab sample for VOCs based on the highest PID reading. Samples shall be analyzed at a minimum for VOCs, SVOCs, and RCRA metals plus any site specific COCs. 20 EMP Version 3, March 2023 PRIOR TO EXPORT FROM THE BROWNFIELDS PROPERTY, a Soil Export Request must be submitted for DEQ Brownfields review and approval. The request shall consist of a Data Package that details: - Proposed Receiving Facility - Analytical data that has been sampled in accordance with the above referenced frequency and following procedures outlined in the most recent Brownfields Redevelopment Section Environmental Site Assessment Work Plan Minimum Requirements Checklist (Checklist) and in accordance with DEQ IHSB Guidelines for Assessment and Cleanup of Contaminated Sites (Guidelines) - A table comparing the export soil to concentrations on the receiving site concentrations including risk comparison (Note that calculated risk cannot be increased on the receiving site) - A North Carolina PE/PG recommendation of export - Written approval from the receiving site property owner representative for export - All relevant attachments listed in the Checklist Soil Export Options Impacts Options Use as Beneficial Fill Off-site disposal at other Brownfields Property2,6,7 Off-site disposal at LCID/CD Landfill1, 3 Off-site disposal at Subtitle D MSW/Permitted Landfarm4 All Constituents below applicable PSRGs X X X X Constituents5 below applicable PSRGs; Metals below background but above PSRGs X X X Constituents5 below applicable PSRGs; Metals above Background /PSRGs X X X Constituents above Applicable PSRGs X X 1: Requires Prior Written DEQ Approval 2: VOC impacted soils above applicable PSRGs shall not be placed directly beneath building footprints without prior written DEQ approval. 3: Requires comparison to site specific metals concentrations. 4: Facility to determine if they can accept soil within their permit. 5: Constituents indicate any samples evaluated for other than metals. 6: Requires written approval from receiving site property owner representative. 7. Site COCs must be in comparable concentrations to receiving site and not significantly raise risk of the receiving site. ☒ Check to confirm that by the owner’s signature and the North Carolina Professional Engineer/Geologist sealing this EMP the consultant understands that no work plan for suspect soil sample collection will be submitted beyond this EMP, and that it is the responsibility of the sealing professional and property owner to ensure that all applicable guidelines are followed and reported in 21 EMP Version 3, March 2023 the Soil Export Request for DEQ approval. Failure to meet these requirements could result in resampling and/or failure to approve export. If other special considerations apply, discuss: In situ soil characterization assessment activities were completed at the site in April 2023. Based on the results of the assessment activities, approximately 40,650 cubic yards of excess soil that do not contain compound concentrations above the PSRGs (or background levels in the case of metals) will be directly loaded onto trucks and transported off-site to an LCID landfill, other Brownfields property, Subtitle D Landfill, or other locations with DEQ prior approval. Approximately 9,850 cubic yards of excess soil that contains compound concentrations above the PSRGs (or background levels in the case of metals) will be transported off-site for disposal at another Brownfields property, a Subtitle D Landfill, or other location with DEQ prior approval. Approximately 1,200 cubic yards of excess soil that contains compound concentrations above the PSRGs will be transported off-site for disposal at a Subtitle D Landfill or other location with DEQ prior approval. Additional information is provided under Contaminated Media, Part 1. Soil, Subsection 7. A summary of in situ soil characterization export options is provided in Attachment 2.2. PART 1.D. MANAGEMENT OF UTILITY TRENCHES ☐ Install liner between native impacted soils and base of utility trench before filling with clean fill (Preferred) ☒ Last out, first in principle for impacted soils (if soil can safely be reused onsite and is not a hazardous waste), i.e., impacted soils are placed back at approximately the depths they were removed from such that impacted soil is not placed at a greater depth than the original depth from which it was excavated. ☒ Evaluate whether necessary to install barriers in conduits to prevent soil vapor transport, and/or degradation of conduit materials due to direct impact with contaminants. ☒ If yes, provide specifications on barrier materials or provide the results of this evaluation in the Vapor Mitigation Plan. Note that if vapor mitigation is planned for site buildings, utility corridors will need to be evaluated as part of mitigation designs: The PD plans to install a vapor barrier and passive-to-active vapor intrusion mitigation system (VIMS) during construction. As part of the VIMS design, the locations of sub-grade utilities will be evaluated to confirm that the proposed VIMS will effectively minimize potential vapor intrusion from lateral migration of vapors through utility trenches. The Vapor Intrusion Mitigation Plan will be submitted under separate cover. ☐ If no, include rationale here: Click or tap here to enter text. ☒ Unknown, details to be provided in the Vapor Mitigation Plan for site buildings 22 EMP Version 3, March 2023 Other comments regarding managing impacted soil in utility trenches: During utility installation activities, workers and contractors will observe soil for evidence of potential impacts. Evidence of potentially impacted soil includes a distinct unnatural color, strong odor, or filled or previously disposed materials of potential environmental concern (i.e., chemicals, tanks, drums, etc.). Should the above be observed during site work, the contractor will stop all work and contact ONE to assess the suspect condition. If ONE confirms that the material may be impacted, then the procedures outlined in Part 1.A. Managing Onsite Soil above will be implemented. In addition, the DEQ Brownfields project manager will be contacted within 48 hours to advise of the condition. Should impacted soil be discovered during utility installation activities, appropriate safety screening of the vapors will be performed to protect workers. Appropriate safety screening activities include monitoring the breathing zone with a calibrated photoionization detector or similar instrument. If results indicate further action is warranted to protect workers from vapors, appropriate engineering controls (such as the use of industrial fans) will be implemented. PART 2. GROUNDWATER 1) What is the depth to groundwater at the Brownfields Property? Depth to groundwater was measured ranging from approximately 15 ft bgs in the low-lying western portion of the site to approximately 27 ft bgs in the higher-elevated southeastern portion of the site. A site potentiometric map is included as Attachment 2.6. Monitoring well locations are also shown in Attachment 2.0. A tabular summary of groundwater elevations is included in Attachment 7.0. 2) What is the maximum depth of soil disturbance onsite? Cut depths extend to approximately 20 ft bgs. Bedrock is anticipated to be encountered at depths beyond 20 ft bgs. 3) Is groundwater known to be contaminated by ☐onsite ☒offsite ☐both or ☐unknown sources? Describe source(s): ONE collected groundwater samples from preexisting monitoring wells during assessment activities conducted in April 2023. As shown in Attachment 2.0, MW-1 through MW-3 were located on the Dynamic Auto Works II property. MW-4 was located on the Foundry property. Groundwater is known to be impacted by TCE as a result of an offsite release from the former H.M. Wade Furniture/textile chemical facility located adjacent and topographically up-gradient of the property. A summary of the most recent groundwater assessment results is provided below: Volatile Organic Compounds (VOCs) Laboratory analytical results reported low detections of VOCs across the site and at estimated laboratory values denoted by a “J”. Only trichloroethene (TCE) was detected at concentrations above the 15A NCAC 02L .0202 Groundwater Quality Standards (2L GWQS) in two (2) sample locations and the consequent investigation derived waste (IDW). Samples MW-2, MW-3, and the IDW reported TCE concentrations of 71.5 μg/L, 83.4 μg/L, and 45.2 μg/L, respectively. 23 EMP Version 3, March 2023 Semi-Volatile Organic Compounds (SVOCs) Laboratory analytical results reported low detections of SVOCs in one sample at estimated laboratory values analyzed outside of sample hold time denoted by a “J” and “H.” Sample MW- 01 reported detections of diethyl phthalate (0.868 JH μg/L) and dimethyl phthalate (3.81 JH μg/L) at concentrations below the 2L GWQS and GCL. No other SVOCs were detected. Metals Laboratory analytical results reported low detections of several metals across the site, including barium (up to 90.2 μg/L), total chromium (up to 3.74 μg/L), lead (up to 0.561 J μg/L), and selenium (up to 1.51 μg/L). No metal concentrations were reported above the 2L GWQS or GCL. A tabular summary of groundwater sample analytical results is included in Attachment 6.2. Sample MW-4 reported no exceedances of 2L GWQS or GCLs. A map depicting groundwater sample locations with 2L GWQS analytical exceedances is shown in Attachment 2.3. 4) What is the direction of groundwater flow at the Brownfields Property? The direction of groundwater flow is expected to be northwest toward Irwin Creek as shown in figure 2.6. This is consistent with surface topography, as shown in Attachments 3.0 and 3.1. 5) Will groundwater likely be encountered during planned redevelopment activities (e.g. footer/utility construction or helical pilings?) ☒Yes ☐No If yes, describe these activities: Groundwater may be encountered during redevelopment activities including excavations for deeper foundational components associated with the proposed building. If groundwater is encountered during redevelopment activities, the procedures outlined below will be implemented. In the event that groundwater is encountered during redevelopment activities (even if no is checked above), list activities for contingent management of groundwater (e.g., dewatering of groundwater from excavations or foundations, containerizing, offsite disposal, discharge to sanitary sewer, NPDES permit, or sampling procedures). If groundwater is encountered during redevelopment activities and gathers in an open excavation, appropriate worker safety measures will be undertaken. The contractor will contact ONE to assess the area of accumulation. The accumulated water will be allowed to evaporate/infiltrate to the extent that dissipation does not disrupt the construction schedule. Should the time needed for the natural dissipation of accumulated water be deemed inadequate, the water will be pumped into a holding container, sampled for the presence of VOCs, SVOCs, and RCRA metals, and disposed of at an appropriate off-site facility. Accumulated water that does not contain constituents above 2L Standards and the NCDEQ Surface Water Standards will be managed on-site by being discharged to the stormwater system following consultation with local stormwater officials and in accordance with applicable municipal and State regulations for erosion control and construction stormwater control. In accordance with 15A North Carolina Administrative Code (NCAC) 2H .0106 (f)(7), groundwaters generated by well construction or other construction activities are deemed to be permitted pursuant to G.S. 24 EMP Version 3, March 2023 143-215.1(c) provided that no water quality standards are contravened, or expected to be contravened. 6) Are monitoring wells currently present on the Brownfields Property?.................☒Yes ☐No If yes, are any monitoring wells routinely monitored through DEQ or other agencies?..................................................................................................................☐Yes ☒No 7) Please check methods to be utilized in the management of known and previously unidentified wells. ☒ Abandonment of site monitoring wells in accordance with all applicable regulations. It is the Brownfields Redevelopment Section’s intent to allow proper abandonment of well(s) as specified in the Brownfields Agreement, except if required for active monitoring through another section of DEQ or the EPA. ☐ Location of existing monitoring wells marked ☐ Existing monitoring wells protected from disturbance ☒ Newly identified monitoring wells will be marked and protected from further disturbance until notification to DEQ Brownfields can be made and approval for abandonment is given. 8) Please provide additional details as needed: Please note, disturbance of existing site monitoring wells without approval by DEQ is not permissible. If monitoring wells are damaged and/or destroyed, DEQ may require that the PD be responsible for replacement of the well. PART 3. SURFACE WATER 1) Is surface water present at the property? ☒ Yes ☐ No 2) If yes, attach a map showing the location of surface water at the Brownfields Property 3) Is surface water at the property known to be contaminated? ☐ Yes ☒ No ☐ Unknown 4) Will workers or the public be in contact with surface water during planned redevelopment activities or as part of the final redevelopment? ☒ Yes ☐ No 5) In the event that contaminated surface water is encountered during redevelopment activities, or clean surface water enters open excavations, list activities for management of such events (e.g. flooding, contaminated surface water run-off, stormwater impacts): All surface water activities will be performed in compliance with United States Army Corps of Engineers (USACE) Nationwide Permit 29, Residential Developments (Attachment 4.0). There are no known impacts to surface water on site. In the unlikely event suspected contaminated surface water is encountered during redevelopment activities, the contractor will contact ONE to assess the area(s) suspected to be impacted. If surface water run-off gathers in an open DEQ will be notified if newly identified monitoring wells are discovered on site. 25 EMP Version 3, March 2023 excavation within an area suspected to be impacted during construction activities, appropriate worker safety and groundwater management measures will be undertaken. The accumulated water will be allowed to evaporate/infiltrate to the extent that dissipation does not disrupt the construction schedule. Should the time needed for the natural dissipation of accumulated water be deemed inadequate, the water will be pumped into a holding container, sampled for the presence of VOCs, SVOCs, and RCRA metals, and disposed of at an appropriate off-site facility. Accumulated water that does not contain constituents above 2L Standards and the NCDEQ Surface Water Standards will be managed on-site by being discharged to the stormwater system following consultation with local stormwater officials and in accordance with applicable municipal and State regulations for erosion control and construction stormwater control. PART 4. SEDIMENT 1) Are sediment sources present on the property? ☒ Yes ☐ No 2) If yes, is sediment at the property known to be contaminated? ☐ Yes ☒ No ☐ Unknown 3) Will workers or the public be in contact with sediment during planned redevelopment activities? ☒ Yes ☐ N 4) Attach a map showing the location of known contaminated sediment at the property. 5) In the event that contaminated sediment is encountered during redevelopment activities, list activities for management of such events (stream bed disturbance): All sediment activities will be performed in accordance with USACE Nationwide Permit 29, Residential Developments (Attachment 4.0). During redevelopment activities, workers and contractors will observe sediment for evidence of potential impacts. Evidence of potentially impacted sediment includes a distinct unnatural color, strong odor, or filled or previously disposed materials of potential environmental concern (i.e., chemicals, tanks, drums, etc.). Should the above be observed during site work, the contractor will stop all work and contact ONE to assess the suspect condition. If ONE confirms that the material may be impacted, then the procedures outlined in Nationwide Permit 29 and Part 1.A. Managing Onsite Soil above will be implemented. In addition, the DEQ Brownfields project manager will be contacted within 48 hours to advise of the condition. Should impacted sediment be discovered during box culvert bypass installation activities, appropriate safety screening of the vapors will be performed to protect workers. Appropriate safety screening activities include monitoring the breathing zone with a calibrated photoionization detector or similar instrument. If results indicate further action is warranted to protect workers from vapors, appropriate engineering controls (such as the use of industrial fans) will be implemented. PART 5. SOIL VAPOR 1) Do concentrations of volatile organic compounds at the Brownfields property exceed the vapor intrusion screening levels (current version) in the following media: 26 EMP Version 3, March 2023 Groundwater Exterior Soil Vapor Sub-Slab Soil Vapor Residential ☒ Yes ☐ No ☐ Unknown ☒ Yes ☐ No ☐ Unknown ☒ Yes ☐ No ☐ Unknown Commercial ☒ Yes ☐ No ☐ Unknown ☒ Yes ☐ No ☐ Unknown ☒ Yes ☐ No ☐ Unknown 2) Attach a map showing the locations of all soil vapor samples including any soil vapor contaminants that exceeds screening levels and overlays planned site development features. 3) If applicable, at what depth(s) is exterior soil vapor known to be contaminated? 4) If applicable, at what depth(s) is sub-slab soil vapor known to be contaminated? ☐0-6 inches ☒Other, please describe: ONE conducted soil gas assessment activities in April 2023 that included the collection of four (4) sub-slab soil gas samples. Tetrachloroethene (PCE) was detected at concentrations above the non-residential DEQ Vapor Intrusion SGSLs. Sample collection depth ranged from nine (9) to 11 inches bgs. Locations of sub-slab soil gas samples and compound concentrations above the DEQ Vapor Intrusion SGSLs are shown in Attachment 2.4. A tabular summary of the sub-slab soil gas analytical data is included in Attachment 6.3. 5) Will workers encounter contaminated exterior or sub-slab soil vapor during planned redevelopment activities? ☐ Yes ☐ No ☒ Unknown In the event that apparent contaminated soil vapor is encountered (based on elevated PID readings, unusual odors, etc.) during redevelopment activities (trenches, manways, basements or other subsurface work,) list activities for management of such contact, INCLUDING notification to DEQ within 48 hours of identification of the issue for determination of additional requirements: If impacted soil vapors are encountered during redevelopment activities, appropriate safety screening of the vapors will be performed to protect workers. Appropriate safety screening activities include monitoring the breathing zone with a calibrated photoionization detector or similar instrument. If results indicate further action is warranted to protect workers from vapors, appropriate engineering controls (such as the use of industrial fans) will be implemented. In addition, the DEQ Brownfields project manager will be contacted within 48 hours to advise of the condition. PART 6. INDOOR AIR 1) Are indoor air data available for the Brownfields Property? ☒ Yes ☐ No ONE conducted soil gas assessment activities in April 2023 that included the collection of 17 exterior soil gas samples. Compounds 1,3-butadiene and trichloroethene (TCE) were detected at concentrations above the non-residential DEQ Vapor Intrusion Soil Gas Screening Levels (SGSLs). Sample collection depths ranged from six (6) to 15 ft bgs. Locations of the exterior soil gas samples and compound concentrations above the DEQ Vapor Intrusion SGSLs are shown in Attachment 2.4. A tabular summary of the soil gas analytical data is included in Attachment 6.3. 27 EMP Version 3, March 2023 2) If applicable, attach a map showing the location(s) where indoor air contaminants exceed site screening levels. 3) If the structures where indoor air has been documented to exceed risk-based screening levels will not be demolished as part of redevelopment activities, will workers encounter contaminated indoor air during planned redevelopment activities? ☐ Yes ☐ No ☐ Unknown ☒ N/A ☒ If no, include rationale here: Indoor air samples were collected at 601 and 619 S Cedar Street in June 2014. A historical sample location map is included in Attachment 2.5. Laboratory analytical results reported no detections of EPA Method TO-15 constituents. A tabular summary of historical indoor air analytical data is included in Attachment 6.4. No indoor air samples have been collected within the footprint of the proposed redevelopment. Existing buildings within the footprint of the proposed redevelopment will be razed. 4) In the event that contaminated indoor air is encountered during redevelopment activities, list activities for management of such contact: VAPOR INTRUSION MITIGATION SYSTEM 1) Is a vapor intrusion mitigation system (VIMS) proposed for this Brownfields Property? ☒ Yes ☐ No ☐ Unknown ☐ If no or unknown, include rationale here as well as plans for pre-occupancy sampling, as necessary: Click or tap here to enter text. If yes, ☐ VIMS Plan Attached or ☒ VIMS Plan to be submitted separately If submitted separately provide date: The PD intends to install a DEQ-approved passive-to-active vapor intrusion mitigation system designed by a North Carolina licensed Professional Engineer. The vapor intrusion mitigation plan will be submitted under separate cover. VIMS Plan shall be signed and sealed by a NC Professional Engineer and follow the DEQ Brownfields Redevelopment Section’s Vapor Intrusion Mitigation System Design Submittal Requirements. Note that approval of this EMP does not imply approval with any vapor intrusion mitigation land In the unlikely event there is evidence of potential indoor air issues (i.e., unusual odors) during redevelopment activities, the area will be evacuated, and appropriate safety screening of the indoor air will be performed. Appropriate safety screening activities include monitoring the breathing zone with a calibrated photoionization detector or similar instrument. If results indicate further action is warranted to protect workers from vapors, appropriate engineering controls (such as the use of industrial fans) will be implemented and DEQ Brownfields will be notified within 48 hours. 28 EMP Version 3, March 2023 use restrictions or requirements of the recorded or draft Brownfields Agreement and that separate approval of mitigation measures will be required. CONTINGENCY PLAN In this section, please provide actions that will be taken to identify or manage unknown potential new sources of contamination. During redevelopment activities, it is not uncommon that unknown tanks, drums, fuel lines, landfills, or other waste materials are encountered. Notification to DEQ Brownfields project manager, UST Section, Fire Department, and/or other officials, as necessary and appropriate, is required when new potential source(s) of contamination are discovered. These Notification Requirements were outlined on Page 1 of this EMP. Should potentially impacted materials be identified that are inconsistent with known site impacts, the DEQ Brownfields project manager will be notified, and a sampling plan will be prepared based on the EMP requirements and site-specific factors. Samples will generally be collected to document the location of the potential impacts. Check the following chemical analysis that are to be conducted on newly identified releases: ☒ Minimum Sample Requirements: Volatile organic compounds (VOCs) by EPA Method 8260; Semi-volatile organic compounds (SVOCs) by EPA Method 8270; and Metals RCRA List + Hexavalent Chromium by EPA Method 6020/7199 ☐ Pesticides: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ PCBs: Specify Analytical Method Number(s): Click or tap here to enter text. ☐ Other Constituents & Analytical Method(s) (e.g. Herbicides) Please note, if field observations indicate the need for additional analyses, they should be conducted, even if not listed here. Click or tap here to enter text. Please provide details on the proposed methods of managing the following commonly encountered issues during redevelopment of Brownfields Properties. Underground Storage Tanks – Note that UST Section guidelines must be followed for sample frequency during UST closure. Unless damage to onsite structures to remain as part of redevelopment would occur, USTs shall be removed from the Brownfields Property: In the event a UST or impacts associated with a UST release are discovered on-site during redevelopment activities, the UST and/or associated impacts will be addressed through DEQ Brownfields. DEQ Brownfields will be notified within 48 hours of discovery. If a UST is encountered, residual fluids (if present) will be removed, sampled for VOCs, SVOCs, and RCRA metals, and transported off-site for disposal at an approved facility. The tank will be assessed 29 EMP Version 3, March 2023 for closure and removal and soil sampling will be performed following DEQ UST Section guidelines. Soil samples will be analyzed for VOCs, SVOCs, RCRA metals, and hexavalent chromium. Impacted soil will be managed under Part 1 A. Managing Onsite Soil. If the UST cannot be removed, DEQ will be notified for approval of in-place closure and soil sampling will be performed following DEQ UST Section guidelines. If present, residual fluids will be removed, sampled for VOCs, SVOCs, and RCRA metals, and transported off-site for disposal at an approved facility. The bottom of the UST may be penetrated to prevent fluid accumulation. Impacted soil will be managed under Part 1.A. Managing Onsite Soil. Sub-Grade Feature/Pit: If a sub-grade feature or pit is encountered and does not require removal, it will be backfilled with demonstrably clean fill material and construction will proceed. Where appropriate, the bottom may be penetrated before backfilling to prevent fluid accumulation. If the pit is observed to contain waste, the waste will be relocated to a secure area and will be sampled for TCLP VOCs, TCLP SVOCs, and TCLP metals. Based on laboratory analytical results, the waste will be disposed of offsite at an approved facility or managed under Part 1.A. Managing Onsite Soil, whichever is most applicable based on the type of waste present. Buried Waste Material – Note that if buried waste, non-native fill, or any obviously filled materials is encountered, the DEQ Brownfields Redevelopment Section must be notified to determine if investigation of landfill gases is required: If excavation into buried wastes or impacted soils occurs, the contractor will cease work in that location and notify ONE. ONE will assess the suspect area and collect samples if warranted. In this event, confirmation sampling will be conducted at representative locations in the base and sidewalls of the excavation after waste or impacted soil is removed. The samples will be analyzed for VOCs, SVOCs, RCRA metals, hexavalent chromium, and any other analyses deemed appropriate based on the type of waste material. If buried debris is encountered, DEQ Brownfields will be notified to determine if methane sampling is required. DEQ Brownfields will be informed regarding the permitted facility used for disposal of the waste and/or impacted soil. Areas of suspected contaminated soil that remain at the site after excavation is complete will be managed under Part 1. A. Managing Onsite Soil. Re-Use of Impacted Soils Onsite: Please refer to the procedures outlined in Part 1.A. Managing Onsite Soil. If unknown, impacted soil is identified onsite, management onsite can be considered after the project team provides the necessary information, outlined in Part 1.A. Item 11, for Brownfields project manager approval prior to final placement onsite. If other potential contingency plans are pertinent, please provide other details or scenarios as needed below: Click or tap here to enter text. 30 EMP Version 3, March 2023 POST-REDEVELOPMENT REPORTING ☒ Check this box to acknowledge that a Redevelopment Summary Report will be required for the project. If the project duration is longer than one year, an annual update is required and will be due by January 31 of each year, or 30 days after each one-year anniversary of the effective date of this EMP (as agreed upon with the project manager). These reports will be required for as long as physical redevelopment of the Brownfields Property continues, except that the final Redevelopment Summary Report will be submitted within 90 days after completion of redevelopment. Based on the estimated construction schedule, the first Redevelopment Summary Report is anticipated to be submitted on 1/31/2025 The Redevelopment Summary Report shall include environment-related activities since the last report, with a summary and drawings, that describes: 1. actions taken on the Brownfields Property; 2. soil grading and cut and fill actions; 3. methodology(ies) employed for field screening, sampling and laboratory analysis of environmental media; 4. stockpiling, containerizing, decontaminating, treating, handling, laboratory analysis and ultimate disposition of any soil, groundwater or other materials suspected or confirmed to be contaminated with regulated substances; and 5. removal of any contaminated soil, water or other contaminated materials (for example, concrete, demolition debris) from the Brownfields Property (copies of all legally required manifests shall be included). ☒ Check box to acknowledge consent to provide a NC licensed P.G. or P.E. sealed, Redevelopment Summary Report in compliance with the site’s Brownfields Agreement. 31 EMP Version 3, March 2023 A. APPROVAL SIGNATURES Brownfields Project Number: 17021-13-060 (primary redevelopment) and 26093-22-060 Brownfields Project Name: Dynamic Auto Works II (primary redevelopment) and Foundry PE/PG Professional License #: 051886 Firm PE/PG License #: P-0771 Insert PE/PG Seal Above Prospective Developer: AP Foundry, LP Date 1/11/2024 Printed Name/Title/Company: Mr. Welch Liles / Managing Director / AP Foundry, LP Consultant: ONE Environmental Group of Carolina, PLLC Date 1/8/2024 Printed Name/Title/Company: Hillary Goodell / Operations Manager / ONE Environmental Group of Carolina, PLLC Brownfields Project Manager: Carolyn Minnich Date Click or tap to enter a date. __________________________________________________ 1/12/2024 32 EMP Version 3, March 2023 • BLAH C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: TEAM MEMBERS PROJECT INFORMATION PROJECT RENDERING VICINITY MAP CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLYING WITH APPLICABLE CODES OR STATUS WHETHER OR NOT SPECIFICALLY REFERENCED IN THE CONSTRUCTION DOCUMENTS THE DRAWINGS FOR THIS PROJECT ARE THE PROPERTY OF DWELL DESIGN STUDIO, LLC. COPIES OF THE DRAWINGS MAY BE USED ONLY BY THE OWNER TO CONSTRUCT AND OCCUPY THIS PROJECT. NEITHER THE DRAWINGS NOR THE DESIGN INDICATED ON THE DRAWINGS MAY BE REPRODUCED NOR USED FOR ANY OTHER PROJECT OR PURPOSE. DWELL DESIGN STUDIO, LLC. ACCEPTS RESPONSIBILITY ONLY FOR THOSE DRAWINGS WHICH HAVE AN ORIGINAL SEAL, SIGNATURE, CONSTRUCTION ISSUE DATE, AND DATE OF FINAL REVISION FOR THE DRAWINGS REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:53:46 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.00 2247601 COVER SHEET SCHEMATIC DESIGN PACKAGE THE FOUNDRY 619 SOUTH CEDAR ST. CHARLOTTE, NC MILL CREEK RESIDENTIAL TRUST, LLC 101 W. WORTHINGTON AVE., SUITE 201 CHARLOTTE, NC 28203 SCHEMATIC DESIGN PACKAGE - 11/30/2022 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCOWNER JUSTIN HOUSTON MILL CREEK RESIDENTIAL TRUST, LLC 101 W. WORTHINGTON AVE, SUITE 210 CHARLOTTE, NC 28203 (704) 942-7639 ARCHITECT JASON R. SHEPARD DWELL DESIGN STUDIO, LLC 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 (770) 864-1035 CIVIL RICHARD PETERSHEIM LANDDESIGN 223 NORTH GRAHAM STREET CHARLOTTE, NC 28202 (704) 333-0325 MECHANICAL SAMUEL WEAVER JORDAN & SKALA ENGINEERS, INC. 4501 CHARLOTTE PARK DR., SUITE 100 CHARLOTTE, NC 28217 (704) 559-4377 ELECTRICAL WILLIAM R. BUSH JORDAN & SKALA ENGINEERS, INC. 4501 CHARLOTTE PARK DR., SUITE 100 CHARLOTTE, NC 28217 (704) 559-4377 PLUMBING SAMUEL WEAVER JORDAN & SKALA ENGINEERS, INC. 4501 CHARLOTTE PARK DR., SUITE 100 CHARLOTTE, NC 28217 (704) 559-4377 FIRE PROTECTION SAMUEL WEAVER JORDAN & SKALA ENGINEERS, INC. 4501 CHARLOTTE PARK DR., SUITE 100 CHARLOTTE, NC 28217 (704) 559-4377 STRUCTURAL MICHAEL STANSBURY SEVEN24 CONSULTING GROUP 119 BALCH SPRINGS CIR. SE LEESBURG, VA 20175 APPLICABLE CODES: • 2018 NC STATE BUILDING CODE • 2018 NC STATE PLUMBING CODE • 2018 NC STATE MECHANICAL CODE • 2018 NC STATE FUEL GAS CODE • 2020 NC STATE ELECTRICAL CODE AMENDMENTS • 2018 NC STATE FIRE CODE • 2018 NC STATE ENERGY CODE • 2018 NC ADMINISTRATIVE CODE & POLICIES ACCESSIBILITY CODES: • 2009 ANSI ICC A117.1 -EFFECTIVE 1/1/2019 • FAIR HOUSING LANDSCAPE/HARDSCAPE DESIGN RICHARD PETERSHEIM LANDDESIGN 223 NORTH GRAHAM STREET CHARLOTTE, NC 28202 (704) 333-0325 INTERIOR DESIGN JOANN MCINNIS CARLYN & COMPANY 746 WALKER ROAD GREAT FALLS, VA 22066 (703) 759 0155 SITE LOCATION N EW S NOTE:RENDERING IS ONLY A GRAPHIC REPRESENTATION OF THE PROJECT AND NOT A CONSTRUCTION DOCUMENT DATE DESCRIPTION REV SHEET INDEX SHEET NUMBER SHEET NAME 2022/11/04 SCHEMATIC DESIGN PACKAGEGENERAL A00.00 COVER SHEET X A00.01 SHEET INDEX X A00.06 GENERAL NOTES X CODE DATA A00.11 UNIT MATRIX AND SCHEDULES X A00.12 BUILDING CODE SUMMARY - APPENDIX B X A00.13 IBC CODE DATA - BUILDING SECTIONS X A00.30 LIFE SAFETY PLAN - LEVEL 1 X A00.35 LIFE SAFETY PLAN - LEVEL 6 X A00.60 FAIR HOUSING ACCESSIBILITY GUIDELINES X A00.61 2010 ADA GUIDELINES X A00.62 2009 ANSI A117.1 GUIDELINES X A00.70 PARTITION & ASSEMBLY GENERAL NOTES X A00.71 MASS WALL PARTITION DETAILS X A00.72 METAL STUD WALL PARTITION DETAILS X A00.73 METAL STUD WALL PARTITION DETAILS X A00.74 WALL PARTITION DETAILS X A00.75 FLOOR/CEILING & ROOF/CEILING ASSEMBLY DETAILS X A00.76 FLOOR/CEILING & ROOF/CEILING ASSEMBLY DETAILS X A00.80 UL ASSEMBLIES - U210 & U344 X A00.81 UL ASSEMBLIES- U305 X A00.82 UL ASSEMBLIES - U301 & D906 X A00.83 UL ASSEMBLIES - U341 & U905 X A00.84 UL ASSEMBLIES - L528 X A00.85 UL ASSEMBLIES - G524 X A00.86 UL ASSEMBLIES - L563 X A00.87 UL ASSEMBLIES - U415 X A00.88 UL ASSEMBLIES - P580 X A00.89 UL ASSEMBLIES - U419 X A00.90 UL ASSEMBLIES - U420 & U428 X A00.91 UL ASSEMBLIES - V454 X A00.92 UL ASSEMBLIES - U425 X ARCHITECTURAL A02.00 SITE PLAN X A02.01 LEVEL 1 OVERALL FLOOR PLAN X A02.01A LEVEL 1 - ENLARGED FLOOR PLAN - AREA A X A02.01B LEVEL 1 - ENLARGED FLOOR PLAN - AREA B X A02.01C LEVEL 1 - ENLARGED FLOOR PLAN - AREA C X A02.02 LEVEL 2 OVERALL FLOOR PLAN X A02.02A LEVEL 2 - ENLARGED FLOOR PLAN - AREA A X A02.02B LEVEL 2 - ENLARGED FLOOR PLAN - AREA B X A02.02C LEVEL 2 - ENLARGED FLOOR PLAN - AREA C X A02.03 LEVEL 3 OVERALL FLOOR PLAN X A02.03A LEVEL 3 - ENLARGED FLOOR PLAN - AREA A X A02.03B LEVEL 3 - ENLARGED FLOOR PLAN - AREA B X A02.03C LEVEL 3 - ENLARGED FLOOR PLAN - AREA C X A02.04 LEVEL 4 OVERALL FLOOR PLAN X A02.04A LEVEL 4 - ENLARGED FLOOR PLAN - AREA A X A02.04B LEVEL 4 - ENLARGED FLOOR PLAN - AREA B X A02.04C LEVEL 4 - ENLARGED FLOOR PLAN - AREA C X A02.05 LEVEL 5 OVERALL FLOOR PLAN X A02.06 LEVEL 6 OVERALL FLOOR PLAN X A02.06A LEVEL 6 - ENLARGED FLOOR PLAN - AREA A X A02.06B LEVEL 6 - ENLARGED FLOOR PLAN - AREA B X A02.06C LEVEL 6 - ENLARGED FLOOR PLAN - AREA C X A02.07 LEVELS 7 OVERALL FLOOR PLAN X A02.07A LEVELS 7 - ENLARGED FLOOR PLAN - AREA A X A02.07B LEVELS 7 - ENLARGED FLOOR PLAN - AREA B X A02.07C LEVELS 7 - ENLARGED FLOOR PLAN - AREA C X A02.08 LEVEL 8 OVERALL FLOOR PLAN X A02.08A LEVEL 8 - ENLARGED FLOOR PLAN - AREA A X A02.08B LEVEL 8 - ENLARGED FLOOR PLAN - AREA B X A02.08C LEVEL 8 - ENLARGED FLOOR PLAN - AREA C X A02.09 LEVEL 9 OVERALL FLOOR PLAN X A02.09A LEVEL 9 - ENLARGED FLOOR PLAN - AREA A X A02.09B LEVEL 9 - ENLARGED FLOOR PLAN - AREA B X A02.10 LEVEL 10 - OVERALL FLOOR PLAN X A02.10A LEVEL 10 - ENLARGED FLOOR PLAN - AREA A X A02.10B LEVEL 10 - ENLARGED FLOOR PLAN - AREA B X A02.11 OVERALL ROOF PLAN X A02.11A ENLARGED ROOF PLAN - AREA A X A02.11B ENLARGED ROOF PLAN - AREA B X A02.11C ENLARGED ROOF PLAN - AREA C X A03.01 STAIR 1 X A03.02 STAIR 2 X A03.03 STAIR 3 X A03.04 STAIR 4 X A03.05 STAIR 5 X A03.06 STAIR DETAILS X A03.07 STAIR DETAILS X A03.08 STAIR DETAILS X A03.09 ELEVATOR 1 X A03.10 ELEVATOR 2 AND 3 X A03.11 TYPICAL ELEVATOR DETAILS X A04.00 UNIT NOTES X A04.01 TYPICAL KITCHEN ELEVATIONS X A04.02 TYPICAL BATH ELEVATIONS X A04.04 S2 UNIT PLANS X A04.05 S3 UNIT PLANS X A04.06 S3_TYPE A UNIT PLANS X A04.07 S4 UNIT PLANS X A04.08 A1 UNIT PLANS X A04.09 A2 UNIT PLANS X A04.10 A2_TYPE A UNIT PLANS X A04.11 A3 UNIT PLANS X A04.12 A4 UNIT PLANS X A04.13 A5 UNIT PLANS X A04.14 A6 UNIT PLANS X A04.15 A7 UNIT PLANS X A04.16 AU1 UNIT PLANS X A04.18 BA1 UNIT PLANS X A04.20 B1 UNIT PLANS X A04.21 B2 UNIT PLANS X A04.22 B3 UNIT PLANS X A04.24 B4 UNIT PLANS X A04.27 B6 UNIT PLANS X A04.28 AD2 UNIT PLANS X A04.30 B10 UNIT PLANS X A05.01 OVERALL BUILDING ELEVATIONS X A05.02 OVERALL BUILDING ELEVATIONS X A05.03 COURTYARD ELEVATIONS X A05.20 SITE AXON VIEWS X A06.01 BUILDING SECTIONS X A06.02 BUILDING SECTIONS X A06.10 SECTION DETAILS X A08.00 WINDOW SCHEDULE X A08.20 STOREFRONT SCHEDULE X A08.21 STOREFRONT SCHEDULE X C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:18:29 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA00.01 2247601 SHEET INDEX SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV TOTAL DRAWINGS ISSUED: 44 M07.02 CALCULATIONS M07.01 CALCULATIONS M06.02 SCHEDULES M06.01 SCHEDULES M05.03 DETAILS M05.02 DETAILS M05.01 DETAILS M04.04 UNIT PLANS M04.03 UNIT PLANS M04.02 UNIT PLANS M04.01 UNIT PLANS M02.10C ROOF PLAN - AREA C M02.10B ROOF PLAN - AREA B M02.10A ROOF PLAN - AREA A M02.09C LEVEL 9-10 - FLOOR PLAN - AREA C M02.09B LEVEL 9-10 - FLOOR PLAN - AREA B M02.09A LEVEL 9-10 - FLOOR PLAN - AREA A M02.08C LEVEL 8 - FLOOR PLAN - AREA C M02.08B LEVEL 8 - FLOOR PLAN - AREA B M02.08A LEVEL 8 - FLOOR PLAN - AREA A M02.07C LEVEL 7 - FLOOR PLAN - AREA C M02.07B LEVEL 7 - FLOOR PLAN - AREA B M02.07A LEVEL 7 - FLOOR PLAN - AREA A M02.06C LEVEL 6 - FLOOR PLAN - AREA C M02.06B LEVEL 6 - FLOOR PLAN - AREA B M02.06A LEVEL 6 - FLOOR PLAN - AREA A M02.05C LEVEL 5 - FLOOR PLAN - AREA C M02.05B LEVEL 5 - FLOOR PLAN - AREA B M02.05A LEVEL 5 - FLOOR PLAN - AREA A M02.04C LEVEL 4 - FLOOR PLAN - AREA C M02.04B LEVEL 4 - FLOOR PLAN - AREA B M02.04A LEVEL 4 - FLOOR PLAN - AREA A M02.03C LEVEL 3 - FLOOR PLAN - AREA C M02.03B LEVEL 3 - FLOOR PLAN - AREA B M02.03A LEVEL 3 - FLOOR PLAN - AREA A M02.02C LEVEL 2 - FLOOR PLAN - AREA C M02.02B LEVEL 2 - FLOOR PLAN - AREA B M02.02A LEVEL 2 - FLOOR PLAN - AREA A M02.01C LEVEL 1 - FLOOR PLAN - AREA C M02.01B LEVEL 1 - FLOOR PLAN - AREA B M02.01A LEVEL 1 - FLOOR PLAN - AREA A M00.03 SEQUENCES M00.02 GENERAL NOTES M00.01 COVER SHEET SHEET NO. SHEET NAME DRAWING INDEX - MECHANICAL TOTAL DRAWINGS ISSUED: 36 P04.02 UNIT PLANS P04.01 UNIT PLANS P02.09B LEVEL 9-10 - FLOOR PLAN - AREA B P02.09A LEVEL 9-10 - FLOOR PLAN - AREA A P02.08C LEVEL 8 - FLOOR PLAN - AREA C P02.08B LEVEL 8 - FLOOR PLAN - AREA B P02.08A LEVEL 8 - FLOOR PLAN - AREA A P02.07C LEVEL 7 - FLOOR PLAN - AREA C P02.07B LEVEL 7 - FLOOR PLAN - AREA B P02.07A LEVEL 7 - FLOOR PLAN - AREA A P02.06C LEVEL 6 - FLOOR PLAN - AREA C P02.06B LEVEL 6 - FLOOR PLAN - AREA B P02.06A LEVEL 6 - FLOOR PLAN - AREA A P02.05C LEVEL 5 - FLOOR PLAN - AREA C P02.05B LEVEL 5 - FLOOR PLAN - AREA B P02.05A LEVEL 5 - FLOOR PLAN - AREA A P02.04C LEVEL 4 - FLOOR PLAN - AREA C P02.04B LEVEL 4 - FLOOR PLAN - AREA B P02.04A LEVEL 4 - FLOOR PLAN - AREA A P02.03C LEVEL 3 - FLOOR PLAN - AREA C P02.03B LEVEL 3 - FLOOR PLAN - AREA B P02.03A LEVEL 3 - FLOOR PLAN - AREA A P02.02C LEVEL 2 - FLOOR PLAN - AREA C P02.02B LEVEL 2 - FLOOR PLAN - AREA B P02.02A LEVEL 2 - FLOOR PLAN - AREA A P02.01C-UF LEVEL 1 - UNDER FLOOR - AREA C P01.03 LEVEL 3 - FLOOR PLAN - SITE PLAN P01.01 LEVEL 1 - UNDERFLOOR - SITE PLAN P00.06 RISER DIAGRAMS P00.05 RISER DIAGRAMS P00.04 RISER DIAGRAMS P00.03 RISER DIAGRAMS P00.02 PLUMBING DETAILS P00.01 PLUMBING DETAILS P00.00 PLUMBING LEGEND, SCHEDULES AND NOTES FP00.00 FIRE PROTECTION - LEGEND, SCHEDULES AND DETAILS SHEET NO. SHEET NAME DRAWING INDEX -PLUMBING TOTAL DRAWINGS ISSUED: 36 E05.01 ELECTRICAL RISER DIAGRAM E04.04 UNIT PLANS E04.03 UNIT PLANS E04.02 UNIT PLANS E04.01 UNIT PLANS E02.10C ROOF PLAN - AREA C E02.10B ROOF PLAN - AREA B E02.10A ROOF PLAN - AREA A E02.09C LEVEL 9-10 - FLOOR PLAN - AREA C E02.09B LEVEL 9-10 - FLOOR PLAN - AREA B E02.09A LEVEL 9-10 - FLOOR PLAN - AREA A E02.08C LEVEL 8 - FLOOR PLAN - AREA C E02.08B LEVEL 8 - FLOOR PLAN - AREA B E02.08A LEVEL 8 - FLOOR PLAN - AREA A E02.07C LEVEL 7 - FLOOR PLAN - AREA C E02.07B LEVEL 7 - FLOOR PLAN - AREA B E02.07A LEVEL 7 - FLOOR PLAN - AREA A E02.06C LEVEL 6 - FLOOR PLAN - AREA C E02.06B LEVEL 6 - FLOOR PLAN - AREA B E02.06A LEVEL 6 - FLOOR PLAN - AREA A E02.05C LEVEL 5 - FLOOR PLAN - AREA C E02.05B LEVEL 5 - FLOOR PLAN - AREA B E02.05A LEVEL 5 - FLOOR PLAN - AREA A E02.04C LEVEL 4 - FLOOR PLAN - AREA C E02.04B LEVEL 4 - FLOOR PLAN - AREA B E02.04A LEVEL 4 - FLOOR PLAN - AREA A E02.03C LEVEL 3 - FLOOR PLAN - AREA C E02.03B LEVEL 3 - FLOOR PLAN - AREA B E02.03A LEVEL 3 - FLOOR PLAN - AREA A E02.02C LEVEL 2 - FLOOR PLAN - AREA C E02.02B LEVEL 2 - FLOOR PLAN - AREA B E02.02A LEVEL 2 - FLOOR PLAN - AREA A E02.01C LEVEL 1 - FLOOR PLAN - AREA C E02.01B LEVEL 1 - FLOOR PLAN - AREA B E02.01A LEVEL 1 - FLOOR PLAN - AREA A E00.00 ELECTRICAL TITLE SHEET SHEET NO. SHEET NAME DRAWING INDEX - ELECTRICAL TOTAL SHEETS: 59 S05.21 ROOF FRAMING DETAILS S05.14 WOOD FRAMING AT BALCONIES S05.13 WOOD FRAMING AT BALCONIES S05.12 WOOD FRAMING DETAILS S05.11 TYPICAL WOOD FRAMING DETAILS S04.11 SHEAR WALL DETAILS S04.01C SHEAR WALL LAYOUT PLAN - PART C S04.01B SHEAR WALL LAYOUT PLAN - PART B S04.01A SHEAR WALL LAYOUT PLAN - PART A S03.11B LEVEL 11 ROOF FRAMING PLAN - PART B S03.11A LEVEL 11 ROOF FRAMING PLAN - PART A S03.10B LEVEL 10 FLOOR FRAMING PLAN - PART B S03.10A LEVEL 10 FLOOR FRAMING PLAN - PART A S03.09C LEVEL 9 LOW ROOF FRAMING PLAN - PART C S03.09B LEVEL 9 FLOOR FRAMING PLAN - PART B S03.09A LEVEL 9 FLOOR FRAMING PLAN - PART A S03.08C LEVEL 8 FLOOR FRAMING PLAN - PART C S03.08B LEVEL 8 FLOOR FRAMING PLAN - PART B S03.08A LEVEL 8 FLOOR FRAMING PLAN - PART A S03.07C LEVEL 7 FLOOR FRAMING PLAN - PART C S03.07B LEVEL 7 FLOOR FRAMING PLAN - PART B S03.07A LEVEL 7 FLOOR FRAMING PLAN - PART A S03.06C LEVEL 6 FLOOR FRAMING PLAN - PART C S03.05C LEVEL 5 FLOOR FRAMING PLAN - PART C S02.06BR LEVEL 6 ELEVATED SLAB REINF. PLAN - PART B S02.06B LEVEL 6 ELEVATED SLAB PLAN - PART B S02.06AR LEVEL 6 ELEVATED SLAB REINF. PLAN - PART A S02.06A LEVEL 6 ELEVATED SLAB PLAN - PART A S02.05BR LEVEL 5 ELEVATED SLAB REINF. PLAN - PART B S02.05B LEVEL 5 ELEVATED SLAB PLAN - PART B S02.05AR LEVEL 5 ELEVATED SLAB REINF. PLAN - PART A S02.05A LEVEL 5 ELEVATED SLAB PLAN - PART A S02.04CR LEVEL 4 ELEVATED SLAB REINF. PLAN - PART C S02.04C LEVEL 4 ELEVATED SLAB PLAN - PART C S02.04BR LEVEL 4 ELEVATED SLAB REINF. PLAN - PART B S02.04B LEVEL 4 ELEVATED SLAB PLAN - PART B S02.04AR LEVEL 4 ELEVATED SLAB REINF. PLAN - PART A S02.04A LEVEL 4 ELEVATED SLAB PLAN - PART A S02.03CR LEVEL 3 ELEVATED SLAB REINF. PLAN - PART C S02.03C LEVEL 3 ELEVATED SLAB PLAN - PART C S02.03BR LEVEL 3 ELEVATED SLAB REINF. PLAN - PART B S02.03B LEVEL 3 ELEVATED SLAB PLAN - PART B S02.03AR LEVEL 3 ELEVATED SLAB REINF. PLAN - PART A S02.03A LEVEL 3 ELEVATED SLAB PLAN - PART A S02.02C LEVEL 2 ELEVATED SLAB PLAN - PART C S02.02B LEVEL 2 SLAB/FOUNDATION PLAN - PART B S02.02A LEVEL 2 ELEVATED SLAB PLAN - PART A S02.01C FOUNDATION PLAN - PART C S02.01B FOUNDATION PLAN - PART B S02.01A FOUNDATION PLAN - PART A S01.61 MASONRY DETAILS S01.42 ELEVATED SLAB DETAILS S01.41 TYPICAL ELEVATED SLAB DETAILS S01.21 CONCRETE COLUMN DETAILS S01.12 FOUNDATION DETAILS S01.11 TYPICAL FOUNDATION DETAILS S00.03 COUNTY SPECIAL INSPECTIONS FORMS S00.02 GENERAL SCHEDULES AND SPECIAL INSPECTIONS S00.01 DESIGN CRITERIA AND STRUCTURAL SPECIFICATIONS SHEET NO. SHEET NAME SHEET INDEX - STRUCTURAL TOTAL DRAWINGS ISSUED: 14 C8-00 REQUIRED PLANTING PLAN C7-10 UTILITY DETAILS C7-00 UTILITY PLAN C6-10 STORM DETAILS C6-01 STORM PROFILES C6-00 STORMWATER PLAN C5-00 OVERALL GRADING PLAN C4-01 PRODUCT SCHEDULE C4-00 MATERIALS PLAN C3-01 EROSION CONTROL PH 2 C3-00 EROSION CONTROL PH 1 C2-00 DEMOLITION PLAN C1-10 OVERALL SITE PLAN C1-00 COVER SHEET NO. SHEET NAME DRAWING INDEX - CIVIL AB.ANCHOR BOLT ABV.ABOVE ACT.ACOUSTICAL TILE ADH.ADHESIVE ADJ. ADJUSTABLE A.F.F ABOVE FINISH FLOOR ALUM.ALUMINUM ALT.ALTERNATE APPROX.APPROXIMATELY ARCH.ARCHITECT/ARCHITECTURAL ASHP.ASPHALT AVG.AVERAGE BALC.BALCONY BD.BOARD BDRM.BEDROOM BLDG.BUILDING BLKG.BLOCKING BM. BEAM BRK.BREAK B.O.BOTTOM OF BRNG.BEARING BSMT.BASEMENT B.T.U./HR.BRITISH THERMAL UNIT/OUR BF.BI-FOLD C. CELSIUS CAB.CABINET C.F.M.CUBIC FEET OF AIR PER MINUTE C.I.P.CAST-IN-PLACE C.I.S.CONTINUOUS INSULATION SYSTEM C.J.CONTROL JOINT C.L.CENTER LINE CLO.CLOSET CLG.CEILING C.M.U CONCRETE MASONRY UNIT COL. COLUMN COMP.COMPOSITION CONC.CONCRETE CONST.CONSTRUCTION CONT.CONTINUOUS CORR.CORRIDOR CPT.CARPET C.T.CERAMIC TILE DEG.DEGREE D.F.DRINKING FOUNTAIN DIA.DIAMETER DIM.DIMENSION DN.DOWN DR.DOOR D.S.DOWN SPOUT DWGS.DRAWINGS EA.EACH E.F.EXHAUST FAN E.J.EXPANSION JOINT EL.ELEVATION ELEC.ELECTRICAL ELEV.ELEVATOR E.O.C.END OF CARPET EQ.EQUAL EQUIP.EQUIPMENT E.W.EACH WAY E.W.C.ELECTRICAL WATER COOLER E.W.H ELECTRIC WATER HEATER EXIST.EXISTING EXP.EXPANSION EXT.EXTERIOR F.FAHRENHEIT FAB.FABRICATE F.A.C FIRE ALARM CABINET F.B.O.FURNISHED BY OTHER F.C.FIRE CODE F.D.FLOOR DRAIN FDN FOUNDATION F.E.FIRE EXTINGUISHER F.E.C.FIRE EXTINGUISHER CABINET F.F.FINISH FLOOR F.F.E.FINISH FLOOR ELEVATION FIN.FINISH FLASH.FLASHING FLOUR.FLUORESCENT FLR.FLOOR F.O.F.FACE OF FINISH F.P.FIRE PLACE F.P.M.FOOT/MINUTE FT.FOOT/FEET FTG.FOOTING FURN.FURNISHED FURR.FURRING FMG.FRAMING FR.FRAME GALV.GALVANIZED GA.GAUGE GEN.GENERAL G.C.GENERAL CONTRACTOR G.B GRAB BAR GL.GLASS G.P.M.GALLONS PER MINUTE GR.GRADE GYPBD.GYPSUM BOARD HC.HANDICAPPED HD. HT. HEAD HEIGHT HDR.HEADER HDW.HARDWARE H.M.HOLLOW METAL HORIZ.HORIZONTAL H.P.HORSE POWER HR.HOUR HT.HEIGHT H.V.A.C.HEATING, VENTILATION, & AIR CONDITIONING HWD.HARDWARE HZ.HERTZ I.D.INSIDE DIAMETER IN.INCH INSUL.INSULATION INT.INTERIOR JAN.JANITOR JB.JAMB JST.JOIST JT.JOINT KIT.KITCHEN L.LIGHT LAM.LAMINATE LAV.LAVATORY MAS.MASONRY MAT.MATERIAL MAX.MAXIMUM M.C.MEDICINE CABINET M.D.MASONRY DIMENSION M.D.O.MEDIUM DENSITY OVERLAY MECH.MECHANICAL MFR.MANUFACTURER MIN.MINIMUM MISC.MISCELLANEOUS M.M.MOLDED MASONITE M.O.MASONRY OPENING MTD.MOUNTED MTL METAL M.W.W.T.METAL WITH WOOD TRIM N.NORTH NAT.NATURAL N/A NOT APPLICABLE N.I.C NOT IN CONTRACT NO.NUMBER NOM.NOMINAL N.T.S NOT TO SCALE O.C.ON CENTER O.C.E.W ON CENTER EACH WAY O.D.OUTSIDE DIAMETER O.H.D OVER HEAD DOOR OPG.OPENING OPP.H.OPPOSITE HAND O.S.B ORIENTED STRAND BOARD PR.PAIR PART.PARTITION PC.PRE-CAST PL.PLATE PLAS.LAM.PLASTIC LAMINATE(PL.) PLYWD.PLYWOOD. PNT.PAINT(ED) PREFAB.PRE-FABRICATED P.S.F.POUND PER SQUARE FOOT P.S.I.POUND PER SQUARE INCH P.T.PRESSURE TREATED P.T.D PAPER TOWEL DISPENSER PVMT.PAVEMENT Q.T.QUARRY TILE QTY.QUANTITY R.RADIUS OR RISER R.D.ROOF DRAIN R & S ROD & SHELF RECPT.RECEPTION REF.REFRIGERATOR REINF.REINFORCING REQ'D REQUIRED REV.REVISION R.H.RIGHT HAND RM.ROOM R.O.ROUGH OPENING R.O.W RIGHT OF WAY RSTRM.RESTROOM S.SPECIFIED OR SPECIFICATION S.A.B.SOUND ATTENUATION BLANKET S.C.W.D SOLID CORE WOOD DOOR SCHED.SCHEDULE S.D.SOAP DISH SECT.SECTION S.F.SQUARE FOOT.(FEET) S.F.E.SUB FLOOR ELEVATION S.H.SHOWER HEAD SHT.SHEET SIM.SIMILAR SPEC.SPECIFICATION SQ.SQUARE S.R.SHOWER ROD S.R.O.SHEET ROCK OPENING S.T.C SOUND TRANSMISSION CLASS STD.STANDARD STL.STEEL STOR.STORAGE STRUC.STRUCTURAL SUSP.SUSPENDED T.THREAD, TILE OR TOP T.O.S.TOP OF SLAB T/-TOP OF _ T+G TONGUE AND GROOVE T.C.TOP OF CURB T.B.TOWEL BAR TEL.TELEPHONE TEMP.TEMPERATURE THK.THICK THR.THRESHOLD T.W.TOP OF WALL TYP.TYPICAL U.L.UNDERWRITERS LABORATORIES U.N.O UNLESS NOTED OTHERWISE UR.URINAL V.C.T VINYL COMPOSITION TILE VERT VERTICAL VEST.VESTIBULE VIN.VINYL V.W.C.VINYL WALL COVERING W.WEST OR WIDTH WD.WOOD W.I.C WALK IN CLOSET WT.WEIGHT W.W.F.WELDED WIRE FABRIC W.W.M.WELDED WIRE MESH W.W.W.T.WOOD WITH WOOD TRIM @ AT &AND #POUND, NUMBER OWNER 1. THE OWNER SHALL OBTAIN AND PAY FOR THE GENERAL BUILDING PERMITS AND IMPACT FEES. THESE PERMITS SHALL BE PROVIDED TO THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. 2. THE OWNER SHALL APPROVE ALL MATERIAL FINISH AND COLOR SELECTIONS, VIA CONTRACTOR SUBMITTED SHOP DRAWINGS, PRIOR TO ORDERING AND INSTALLATION FOR ANY EQUIPMENT. 3. THE OWNER SHALL COORDINATE AND SECURE AN AGREEMENT FOR ACCESS TO SITE CONSTRUCTION, STAGING AREA, AND STORAGE AREAS. CONTRACTOR 1. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ARCHITECT AND OWNER, IN WRITING, AND SHALL HAVE RESOLVED AND DOCUMENTED, IN WRITING, PRIOR TO CONTINUING WITH THE WORK IN QUESTION IF THERE ARE: A. ANY ERRORS, OMISSIONS, DISCREPANCIES, CONFLICTS, OR INCONSISTENCIES ON THESE CONTRACT DOCUMENTS. B. ANY VARIATION OR AMBIGUITIES BETWEEN THESE DRAWINGS AND ACTUAL SITE AND CONSTRUCTION CONDITIONS AND/OR REQUIREMENTS. C. DISCREPANCIES AND/OR UNCERTAINTIES AS TO WHAT MATERIAL OR PRODUCT IS TO BE USED. 2. THE CONTRACTOR SHALL NOT RELY SOLELY ON THE ELECTRONIC VERSIONS OF THE PLANS, SPECIFICATIONS, AND DATA FILES THAT ARE OBTAINED FROM THE DESIGNERS, BUT SHALL VERIFY THE LOCATION OF PROJECT FEATURE DIMENSIONS IN ACCORDANCE WITH THE HARD COPIES OF THE PLANS AND SPECIFICATIONS THAT ARE SUPPLIED AS PART OF THE CONTRACT DOCUMENTS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR: A. COORDINATION OF CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, AND PROCEDURES REQUIRED FOR SAFE EXECUTION OF EFFICIENT AND ORDERLY INSTALLATION OF EACH PART OF WORK TO BE COMPLETED. B. INITIATING, MAINTAINING, AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK. 4. THE CONTRACTOR SHALL: A. OBTAIN AND PAY FOR ALL OTHER PERMITS, CERTIFICATIONS AND APPROVALS REQUIRED IN CONNECTION WITH ALL WORK UNDER CONTRACT DOCUMENTS THAT ARE NOT PROVIDED BY THE OWNER. B. SURVEY THE PROJECT AND BECOME FAMILIAR WITH THE EXISTING CONDITIONS. VERIFY ALL SITE DIMENSIONS ON CIVIL DRAWINGS, EXISTING CONSTRUCTION GRADES AND UTILITIES ON PROJECT AT PROJECT SITE PRIOR TO BEGINNING PROJECT. C. EXAMINE AND BECOME FAMILIAR WITH ALL CONTRACT DOCUMENTS AND SCOPE OF WORK IN THEIR ENTIRETY. ALL ITEMS INDICATED ON ANY DRAWING SHALL BE INCLUDED AS A COMPLETE SYSTEM, UNLESS NOTED OTHERWISE. D. ALL COSTS SUBMITTED SHALL BE BASED ON THOROUGH KNOWLEDGE OF ALL WORK AND MATERIALS REQUIRED. E. INSURE THAT ALL AREAS ON THE ACCESSIBLE ROUTE THROUGHOUT THE SITE MEET THE REQUIREMENTS OF THE APPLICABLE ACCESSIBILITY CODES. COORDINATE BETWEEN CIVIL AND ARCHITECTURAL PLANS. F. VERIFY ALL DIMENSIONS IN THE FIELD, AND COORDINATE WORK BETWEEN ALL TRADES. G. PAINT ALL SURFACES WHICH REQUIRE PROTECTION FROM THE ELEMENTS WITH THE APPROPRIATE PAINT, INCLUDING NECESSARY PRIMER COATS AND BACK PRIMING. H. SEAL WITH THE APPROPRIATE TYPE OF SEALANT, AND FLASH AT ALL LOCATIONS NECESSARY TO PREVENT PENETRATION OF MOISTURE AT TRANSITIONS OF DISSIMILAR MATERIALS TO INCLUDE, BUT ARE NOT LIMITED TO: a. FLASHING: • CONTINUOUS 25 MIL MEMBRANE FLASHING TO ALL INSIDE AND OUTSIDE WALL CORNERS. • FLASHING SHALL BE INSTALLED AROUND ALL WINDOW OPENINGS, ROOF OPENINGS, AND AT THE INTERSECTION OF CHIMNEYS, WOOD CONSTRUCTION, AND FRAME WALLS. SEAL AND MAKE WEATHER-TIGHT. b. AIR IMPERMEABLE SEALANT: • CONTINUOUS AT ALL EXTERIOR JOINTS AROUND WINDOW FRAMES, DOOR FRAMES, BETWEEN WALL CAVITIES, BETWEEN WALL AND FOUNDATION, BETWEEN WALL AND ROOF, BETWEEN WALL AND PANELS, ALL PENETRATIONS AND UTILITIES THROUGH WALLS AND ROOFS, BETWEEN ALL DISSIMILAR MATERIALS, AND ALL OTHER OPENINGS IN BUILDING ENVELOPE. • PLUMBING & WIRING PENETRATIONS IN ENVELOPE. • SOLE PLATES AT EXTERIOR SLAB ON GRADE c. WEATHERSTRIP: • CONTINUOUS AT ALL EXTERIOR DOORS & WINDOWS. • CONTINUOUS AT ALL ATTIC ACCESSES IN CONDITIONED AREAS. • CONTINUOUS AT INTERIOR DOOR OPENINGS INTO UNTREATED SPACE. d. ALL EXTERIOR WORK SHALL BE INSTALLED IN WEATHER TIGHT MANNER AS REQUIRED. I. EMPLOY, AS REQUIRED BY GOVERNING AUTHORITIES, AN APPROVED TESTING LABORATORY TO MAKE ALL TESTS FOR CONCRETE, SOIL COMPACTION AND WELDING TO INSURE COMPLIANCE WITH PLANS, STANDARDS AND CODES. REFER TO CONCRETE SPECIFICATION FOR FREQUENCY OF TESTING REQUIRED. THESE COSTS SHALL BE INCLUDED IN THE CONTRACT. J. FIELD VERIFY ALL ROUGH OPENINGS. K. FULLY GUARANTEE THE WORK AND EQUIPMENT FOR ONE (1) YEAR FROM THE DATE OF FINAL PAYMENT AND ACCEPTANCE FROM ALL SUBCONTRACTORS AND MATERIAL SUPPLIERS. L. REMOVE RUBBISH FROM PREMISES AS OFTEN AS NECESSARY OR AS DIRECTED. ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO THE OWNER. M. INSPECT, REPAIR AND PREPARE FLOORS AS REQUIRED TO PROVIDE A SATISFACTORY SUB-FLOOR FOR FLOOR FINISH MATERIALS. SATISFACTORY SUB-FLOOR IS DEFINED AS A SURFACE THAT IS FREE FROM CRACKS, HOLES, RIDGES, COATINGS, OR DEFECTS THAT WOULD PREVENT ADHESIVE BOND OR IMPAIR PERFORMANCE OR APPEARANCE OF FINISHED MATERIALS. N. UPON COMPLETION OF THE WORK, REMOVE ALL TOOLS, EQUIPMENT, TEMPORARY PROTECTION, AND EXCESS MATERIALS FROM THE SITE. CLEAN / POLISH ALL HARDWARE AND FIXTURES. CLEAN / REMOVE ALL PAINT DRIPS / SPLATTERS AND STAINS. REMOVE ALL APPLIANCE PROTECTIONS AND LEAVE INTERIOR AREAS BROOM CLEAN, FREE OF STAINS, FILM AND FOREIGN SUBSTANCES. O. BRING TO THE ATTENTION OF THE OWNER ANY MATERIAL SUSPECTED OF BEING HAZARDOUS WHILE ENCOUNTERED DURING EXECUTION OF THE WORK. A DETERMINATION WILL BE MADE BY THE OWNER AS TO WHETHER THE CONTRACTOR SHALL PERFORM TESTS TO DETERMINE IF THE MATERIAL IS HAZARDOUS. 5. THE CONTRACTOR SHALL PROVIDE AND INSTALL: A. ALL NECESSARY FLASHING INCLUDING (BUT NOT LIMITED TO) THROUGH FLASHING, STEP FLASHING, COUNTER FLASHING, CAP FLASHING, BASE FLASHING, AND FLEXIBLE FLASHING, WHERE NECESSARY, TO ENSURE A WATER TIGHT BUILDING. B. CONTINUOUS METAL CORNER BEADS AT ALL GYPSUM BOARD EXTERIOR CORNERS FROM FLOOR TO CEILING. C. CONTINUOUS METAL 'L' BEADS AT ALL EXPOSED GYPSUM BOARD EDGES FROM FLOOR TO CEILING. D. ALL LOCKING DEVICES, SECURITY DEVICES, AND GLASS IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL LAWS, REGULATIONS AND REQUIREMENTS. E. AN INSULATION AND VAPOR BARRIER THAT IS CONTINUOUS AT WALLS, CEILINGS, AND FLOOR SURFACES AT ALL OCCUPIED SPACES EXPOSED TO NON-TEMPERED AREAS. 6. THE CONTRACTOR SHALL PROTECT: A. MATERIALS WHICH ARE SENSITIVE TO DETERIORATION. B. THE REQUIRED PROTECTION OVER SHEAR WALLS AT ALL RATED WALLS AS APPROVED BY THE BUILDING OFFICIAL. C. ALL EXISTING TREES, AS NOTED TO REMAIN ON CIVIL PLANS, SHALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTION BY BOXING OR OTHER OWNER APPROVED MEANS. D. ALL EXISTING WORK, UTILITIES, CONDUIT, PIPING, EQUIPMENT, AND/OR ADJACENT AREAS NOT SHOWN TO BE ALTERED OR REMOVED FROM DAMAGE DURING EXECUTION OF THE WORK. THE CONTRACTOR SHALL BEAR THE TOTAL EXPENSE FOR, AND SHALL REPAIR TO EXISTING CONDITIONS, DAMAGE TO EXISTING CONSTRUCTION, EQUIPMENT, OR IMPROVEMENTS NOT INDICATED IN THE DRAWINGS SPECIFICATIONS TO RECEIVE ALTERATIONS, ADDITIONS, OR REMOVAL. E. EXISTING SURFACE STREET AND SURFACE PARKING AREAS IN A CLEAN CONDITION AND PROVIDE ADEQUATE MEANS TO CLEAN TRUCKS AND OTHER EQUIPMENT. 7. THE CONTRACTOR SHALL PROVIDE FULL SCALE, WOOD FRAMED MOCK-UP WITH ACCURATE DETAILS OF CONSTRUCTION. THE APPROXIMATE SIZE SHALL BE: 20' LONG X 10' HIGH. A. MOCK UP SHALL INCLUDE: 1 DOOR, 2 WINDOWS, CEMENTITIOUS PANEL, BRICK, METAL PANEL, METAL RAILING, ROOF MATERIAL. B. THE LOCATION OF THE MOCK-UP ON THE SITE TO BE APPROVED BY OWNER AND CONTRACTOR. GENERAL 1. THERE SHALL BE NO DEVIATION FROM SPECIFICATIONS WITHOUT THE WRITTEN APPROVAL OF THE OWNER, ARCHITECT, AND/OR ENGINEER 2. QUANTITIES INDICATED ON THE PLANS ARE PROVIDED FOR THE BENEFIT OF THE CONTRACTOR, BUT SHOULD NOT BE ASSUMED TO ALWAYS BE CORRECT. IN THE EVENT OF DISCREPANCY, THE PLAN TAKES PRECEDENCE OVER THE QUANTITY INDICATED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OWN QUANTITY CALCULATIONS AND THE LIABILITY PERTAINING TO THOSE QUANTITIES AND ANY OTHER RELATED CONTRACT DOCUMENTS AND/OR PRICE QUOTATIONS 3. “TYPICAL”MEANS THE REFERENCED DETAIL SHALL APPLY FOR ALL SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. 4. ALL MATERIALS SHALL BE NEW AND SHALL BE INSTALLED IN STRICT CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS AND/OR RECOMMENDATIONS. 5. ROOFING SHALL BE CLASS -B OR BETTER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. 6. INSULATE ALL EXTERIOR WALLS & CONDITIONED SPACES W/ KRAFT FACED FIBERGLASS, UNLESS NOTED OTHERWISE, INSULATION. FRICTION FIT IS NOT ACCEPTABLE TO MEET REQUIRED ENERGY EFFICIENCY STANDARD. 7. FIELD MODIFICATION TO WORK IN PLACE MUST COMPLY WITH THE CUTTING AND PATCHING REQUIREMENTS. 8. GYPSUM WALL BOARD SHALL BE: A. INSTALLED IN CONFORMANCE WITH THE GYPSUM ASSOCIATION'S RECOMMENDED PRACTICES FOR THICKNESS, NAILING, TAPING, AND STUD SPACING. B. 5/8" TYPE "X" MADE IN USA. WITH MATERIAL SOURCE IN THE U.S.A. C. WATER-RESISTANT GYPSUM BOARD AT KITCHEN/TOILET BACKSPLASHES, AND LAUNDRY WET WALLS. 9. FILL ALL CONTROL JOINTS WITH TRAFFIC SEALANT AND EXPANSION JOINTS WITH EXPANSION JOINT SYSTEM IN PARKING DECK 10. SIZE AND LOCATION OF ALL FLOOR OPENINGS TO BE VERIFIED WITH TRADE AFFECTED BEFORE WORK. PATCH AND SEAL ALL PENETRATIONS IN FLOOR TO COMPLY WITH APPLICABLE BUILDING AND/ OR FIRE CODES. 11. MAXIMUM FLAME SPREAD RATING ON ALL INTERIOR FINISH MATERIALS SHALL NOT BE GREATER THAN THE REQUIREMENTS SPECIFIED IN IBC & NFPA 101. SITE 1. ALL SITEWORK AND LANDSCAPING SHALL BE ESTABLISHED AND DESIGNED BY OTHERS (THAN THE ARCHITECT). 2. ALL WORK AND EQUIPMENT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO OWNER. 3. STORE MATERIALS IN SPACES DESIGNATED BY OWNER. 4. REFER TO CIVIL DRAWINGS FOR DIMENSIONAL CONTROL PLAN AND GRADING, FIRE HYDRANT LOCATIONS, AND CURB CUTS. 5. REFER TO LANDSCAPING DRAWINGS FOR LOCATION OF SIDEWALKS AND DETAILS. 6. REFER TO CIVIL AND LANDSCAPE DRAWINGS FOR SITE DETAILS. 7. REFER TO ELECTRICAL AND LANDSCAPING DRAWINGS FOR EXTERIOR BUILDING LIGHTING AND TRANSFORMER LOCATIONS. STRUCTURAL / FRAMING 1. DIMENSIONS: A. ALL DIMENSIONS ON PLANS ARE TO FACE OF STRUCTURE/STUD UNLESS OTHERWISE NOTED. B. ALL ANGLED WALLS ARE 45 DEGREES UNLESS NOTED OTHERWISE. C. DOOR LOCATIONS NOT DIMENSIONED SHALL BE LOCATED AT MIDPOINT OF WALL OR 4" CLEAR OF ROOM, FROM ADJACENT WALL CORNER, TYPICAL IF CLEARANCE ALLOWS. D. DOORS AND WINDOWS ARE DIMENSIONED TO THE CENTERLINE OF THE ELEMENT U.N.O. 2. STRUCTURAL AND FIRE RESISTIVE INTEGRITY IS TO BE MAINTAINED AT ALL PENETRATIONS IN ACCORDANCE WITH THE REQUIREMENTS OF GOVERNING CODES AND AUTHORITIES. 3. SEE STRUCTURAL DRAWINGS FOR SHEAR WALL & NAILING PATTERN TABLE FOR GYPSUM WALL BOARD. 4. WIND BRACE WALLS PER STRUCTURAL DRAWINGS AND PER BUILDING-CODE. 5. FLOOR TOLERANCE: IN LAYING OUT AND DETAILING THE WORK TO BE COMPLETED CONSIDERATION SHALL BE GIVEN TO VARIATIONS IN THE FLOOR LEVEL RESULTING FROM CONSTRUCTION QUALITY AND LIVE AND DEAD LOADS IMPOSED ON THE STRUCTURE. FIELD VERIFICATION SHALL BE MADE OF CONDITIONS TO VERIFY CONSTRUCTION TOLERANCES. 6. ALIGNMENT OF DOOR HEADS AND OTHER HORIZONTAL ELEMENTS SHALL BE MAINTAINED AT A CONSTANT LEVEL AND SHALL NOT FOLLOW VARIATIONS IN FLOOR PLANE. 7. ALL WOOD SILLS IN CONTACT WITH CONCRETE TO BE PRESSURE TREATED AND HAVE A CONTINUOUS SILL SEALER. PROVIDE TERMITE SHIELDS AT CONCEALED UNDER FLOOR SPACES. 8. ALL CHIMNEYS SHALL TERMINATE 2'-0" MINIMUM HEIGHT ABOVE A POINT MEASURED 10'-0 HORIZONTALLY FROM THE NEAREST BUILDING OR ROOF. 9. LUMBER / WALLS: A. COORDINATE LOCATION, CONSTRUCTION AND DETAIL OF LOAD BEARING WALLS BEFORE WORK B. ALL LUMBER SHALL BE GRADE MARKED. C. O.S.B. IS AN ACCEPTABLE SUBSTITUTE FOR PLYWOOD EXCEPT WHERE SPECIFIED BY STRUCTURAL ENGINEER. D. STUD WALLS ARE DIMENSIONED 3-1/2", 5-1/2", OR 7-1/4", UNLESS NOTED OTHERWISE. E. PARTY WALLS ARE DIMENSIONED 8" (3-1/2" + 1" + 3-1/2") F. PLUMBING WALLS SHALL BE FRAMED WITH 2X6 OR 2X8 STUDS, UNLESS NOTED OTHERWISE. G. REFER TO UNIT PLANS FOR LOCATION OF 2X6 WALLS. H. REFER TO STRUCTURAL DRAWINGS FOR UNUSUAL OR SPECIAL FRAMING CONDITIONS I. WATER RESISTANT 1/2" CERAMIC TILE BACK BOARD SHALL BE INSTALL IN BOTH TUB AND SHOWER SURROUNDS, UNLESS NOTED OTHERWISE. J. ALL PENETRATIONS IN GYPSUM DRYWALL CONSTRUCTION SHALL BE SEALED WITH JOINT COMPOUND OR APPROVED ACOUSTICAL SEALANT TO PREVENT SOUND LEAKAGE. K. ALL CAVITY OR CONCEALED SPACES SHALL BE DRAFT STOPPED & FIRE BLOCKED.PROVIDE BLOCKING FOR ALL CABINETS, CEILING FANS, AND BATH ACCESSORIES. INCLUDE BLOCKING FOR GRAB BARS AT ALL LOCATIONS. 10. PATIOS AND BALCONIES SHALL BE SLOPED MIN. 1/4" PER 1'-0"" IN DIRECTION INDICATED OR TO OUTERMOST EDGE OF BUILDING STRUCTURE. 11. ALL EXPOSED MATERIALS FOR BALCONIES, PATIOS, SOFFITS, OVERHANGS ETC. SHALL BE APPROVED EXTERIOR GRADE. 12. BALCONY AND PATIO SUPPORTS VARY ACCORDING TO THE EXTERIOR ELEVATIONS. SEE ELEVATIONS FOR LOCATION OF BRICK PIER, STONE PIER, POLY COLUMN OR RAILINGS AT BALCONIES. 13. PROVIDE GALVANIZED METAL ANCHOR FOR WOOD POSTS BEARING DOWN ON CONCRETE SLABS, UNLESS NOTED OTHERWISE. 14. ALL CONCRETE WORK SHALL CONFORM TO ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS" AND THAT DESIGN IS BASED ON ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE”AND ACI 318.1. “CONCRETE TEST REPORTS”WILL BE AVAILABLE ON JOB SITE IN CONSTRUCTION TRAILER. 15. ALL FRAMING TO BE IN CONFORMANCE WITH THE NATIONAL FOREST PRODUCTS "MANUAL FOR HOUSE FRAMING." 16. FIREBLOCKING SHALL BE PROVIDED TO FORM EFFECTIVE FIRE BARRIERS BETWEEN STORIES AND BETWEEN A STORY AND ROOF SPACE. WHERE FIREBLOCKS ARE WOOD, THEY SHALL NOT BE LESS THAN A NOMINAL TWO INCHES IN THICKNESS. FIRESTOPS SHALL BE LOCATED IN EXTERIOR AND INTERIOR WALLS, PARTITIONS AT CEILING AND FLOOR LEVELS. MECHANICAL, ELECTRICAL, AND PLUMBING 1. ALL PLUMBING CHASES ARE TO EXTEND TO THE UNDERSIDE OF STRUCTURE ABOVE, UNLESS NOTED OTHERWISE. 2. WHERE ELECTRICAL, MECHANICAL, AND/OR OTHER WALL MOUNTED DEVICES OCCUR AT THE SAME LOCATION BUT DIFFERENT HEIGHTS, THEY SHALL BE CENTERED ABOVE EACH OTHER. 3. WATER SERVICE SHALL NOT BE PLACED IN CONCEALED SPACES OUTSIDE OF THE CONDITIONED BUILDING ENVELOPE (BREEZEWAY OR PATIO FLOOR SPACES OR ATTICS). 4. PENETRATIONS AND FIXTURES TO ALIGN VERTICALLY FROM FLOOR TO FLOOR. 5. PROVIDE SUPPORT/REINFORCEMENT TO ACCOMMODATE WALL MOUNTED EQUIPMENT INCLUDING SUPPORT OF FUTURE GRAB BARS IN ALL BATHROOMS AS REQUIRED BY ADA AND/OR FAIR HOUSING ACT. 6. COORDINATE LOCATION AND/OR ELEVATION OF FLOOR DRAINS, REGISTERS, GRILLES, LOUVERS CONVECTORS, PANELS, ETC. WITH MECHANICAL AND ELECTRICAL CONTRACTORS 7. FIRE PROTECTION SYSTEM SHALL BE DESIGNED BY THE FIRE PROTECTION CONTRACTOR. A. PROVIDE COMPLETE DESIGN AND SHOP DRAWINGS FOR FIRE SPRINKLER SYSTEM. B. PROVIDE FOR ALL STATE AND LOCAL SUBMITTALS AND/OR APPROVALS FOR QUICK RESPONSE SPRINKLER SYSTEM. C. ALL SPRINKLER PIPING SUBJECT TO FREEZING SHALL BE DRY-TYPE SYSTEMS WHERE PERMITTED. 8. VENT DRYERS TO OUTSIDE. SEE MECHANICAL DRAWINGS. 9. ALL OUTLETS @ KITCHEN SINK & BATH LAVATORY COUNTERS TO BE GFCI. 10. MECHANICAL DUCTWORK TO BE SEPARATED FROM ELECTRICAL PANELS. 11. SMOKE DETECTORS SHALL NOT BE PLACED IN FRONT OF EXHAUST GRILLS. 12. SMOKE DETECTORS SHALL BE CONTINUOUSLY BE POWERED BY BUILDING ELECTRICAL SYSTEM AND INSTALLED IN ACCORDANCE WITH NFPA AND IBC W/ BATTERY BACK UP. CODE 1. THE CONTRACTOR SHALL MEET: A. ALL REQUIREMENTS OF THE BUILDING CODE AND FEDERAL, STATE, AND LOCAL LAWS, REGULATIONS, AND REQUIREMENTS, EVEN IF IT REQUIRES LABOR AND/OR MATERIALS NOT INDICATED ON PLANS. B. ALL LAWS, ORDINANCES, RULES AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION. C. ALL WORK PERFORMED UNDER, AND IN CONNECTION WITH THESE DRAWINGS SHALL BE IN STRICT COMPLIANCE WITH THE LATEST O.S.H.A SAFETY AND HEALTH STANDARDS. D. OPERATING FEATURES SHALL COMPLY WITH IBC AND NFPA WHILE BUILDING IS UNDER CONSTRUCTION. E. ALL INSTALLED SIGNAGE TO COMPLY WITH 2010 ADA SECTIONS 216 AND 703. 2. PROVIDE ACCESS PANELS AS MANDATED BY LOCAL GOVERNING AUTHORITIES. 3. PROJECT SITE, BUILDINGS AND UNITS SHALL MEET OR EXCEED THE FAIR HOUSING ACCESSIBILITY GUIDELINES AS PUBLISHED IN THE FEDERAL REGISTER VOLUME 56, NUMBER 44, ON MARCH 6, 1991. THE FOLLOWING ARE ADDRESSED IN MEETING THE GUIDELINES: A. ACCESSIBLE ENTRANCES/ ACCESSIBLE ROUTES. B. PUBLIC AND COMMON AREAS MEETING ADA/ANSI AND ADA TITLE II REQUIREMENTS C. USABLE DOORS D. ACCESSIBLE ROUTE INTO AND THROUGH THE COVERED UNIT E. LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTAT, AND ENVIRONMENTAL LOCATIONS F. GRAB BAR REINFORCEMENT LOCATIONS. G. USABLE BATHROOMS AND KITCHENS. 4. ALL HANDICAPPED RAMPS SHALL BE BROOM FINISHED PERPENDICULAR TO SLOPE. SLOPE RAMPS AT 1:12 (MAX). 5. NO FRAMING AT ANY TIME IS TO BE CONCEALED PRIOR TO INSPECTION BY GOVERNING AUTHORITIES 6. WHILE BUILDING IS UNDER CONSTRUCTION, OPERATING FEATURES SHALL COMPLY WITH IBC CHAPTER 33 & NFPA 241. EARTH CONCRETE STEEL CONCRETE MASONRY UNITS WOOD FINISHES WOOD- CONTINUOUS WOOD- BLOCKING INSULATION- BATTS PLYWOOD BRICK GYPSUM- BOARD GRAVEL ALUMINUM INSULATION- RIGID GLAZING (ELEVATION) INTERIOR ELEVATION MARKER EXTERIOR ELEVATION MARKER LEVEL HEAD UNIT TAG SECTION MARK CENTERLINE ENLARGED PLAN MARK NORTH ARROW B01DOOR TYPE W10WINDOW TYPE WALL TYPE STRUCTURAL GRIDLINE BUBBLE ACCESSIBILITY SYMBOL WB1 022 A4-03 3 4 2 1 REFERENCE NUMBER A3-03 6 7 8 5 REFERENCE NUMBER SHEET NUMBER SHEET NUMBER A6-03 3 REFERENCE NUMBER SIMILAR DETAIL SHEET NUMBER SIM. N EW S 2103 BUILDING NUMBER FLOOR NUMBER UNIT NUMBER UNIT # SHEET # UNIT TYPE STOREFRONT TYPE SF01 A2-03 3 REFERENCE NUMBER SIMILAR DETAIL SHEET NUMBER SIM. 55.5 0 CL BUILDING CONTROL- GRID BUBBLE UNIT CENTERLINE BUBBLE C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:53:50 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.06 2247601 GENERAL NOTES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCSYMBOLS GRAPHIC REPRESENTATION ABBREVIATIONS DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:53:57 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.11 2247601 UNIT MATRIX AND SCHEDULES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUNIT MIX SUMMARY (ROOMS) - BUILDINGS UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 703.17 SF 69 48,518.40 SF 18.45% UNIT A2 1 BR / 1 BA 704.35 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710.39 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865.15 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 964.86 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678.05 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730.38 SF 24 17,529.02 SF 6.42% UNIT A7 1 BR / 1 BA 717.54 SF 15 10,763.03 SF 4.01% UNIT AD2 1 BR / 1 BA / D 854.46 SF 18 15,380.28 SF 4.81% UNIT AD2.1 1 BR / 1 BA / D 890.33 SF 8 7,122.61 SF 2.14% UNIT B1 2 BR / 2 BA 1,036.45 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,022.66 SF 5 5,113.31 SF 1.34% UNIT B2.1 2 BR / 2 BA 1,024.98 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026.09 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214.34 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,131.57 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,061.47 SF 3 3,184.42 SF 0.80% UNIT BA1-A 2 BR / 2 BA 1,061.36 SF 2 2,122.72 SF 0.53% UNIT BA1.1 2 BR / 2 BA 1,051.72 SF 10 10,517.18 SF 2.67% UNIT S2 STUDIO 610.96 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 537.71 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 538.74 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 626.63 SF 5 3,133.17 SF 1.34% BUILDING 1: 280 280 236,566.65 SF 74.87% UNIT A1 1 BR / 1 BA 686.44 SF 12 8,237.28 SF 3.21% UNIT A6 1 BR / 1 BA 728.59 SF 6 4,371.55 SF 1.60% UNIT AU1 1 BR / 1 BA 667.80 SF 12 8,013.56 SF 3.21% UNIT AD2 1 BR / 1 BA / D 891.15 SF 6 5,346.90 SF 1.60% UNIT A8 2 BR / 2 BA 848.58 SF 6 5,091.49 SF 1.60% UNIT B2 2 BR / 2 BA 1,070.95 SF 28 29,986.69 SF 7.49% UNIT BA1 2 BR / 2 BA 1,008.95 SF 16 16,143.14 SF 4.28% UNIT BA1-A 2 BR / 2 BA 1,010.20 SF 2 2,020.40 SF 0.53% UNIT C1 2 BR / 2 BA 1,403.09 SF 6 8,418.53 SF 1.60% BUILDING 2: 94 94 87,629.55 SF 25.13% Grand total 374 324,196.20 SF 100.00% UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 AMENITY SF NAME AREA LEASING/LOBBY 5,207.92 SF MAIL ROOM 1,318.52 SF LEVEL 1: 2 6,526.45 SF GAME ROOM 754.92 SF LEVEL 4: 1 754.92 SF AMENITY 1,443.92 SF FITNESS 1,233.70 SF LEVEL 6: 2 2,677.62 SF 9,958.99 SF RETAIL/RESTAURANT NAME AREA RESTAURANT 5,532.54 SF RETAIL 18,180.89 SF LEVEL 1: 6 23,713.42 SF 23,713.42 SF DATE DESCRIPTION REV UL / 85' The Foundry Mecklenburg Mill Creek Residential 704.942.7639 B1 ACT 104' / AGP 79' 601 S Cedar Street, Charlotte, NC UL / 5 5 / 3 jhouston@MCRtrust.com Mixed-Use Residential over Commercial. Five levels of Type III-A Wood construction (residential / amenity) over three levels of cast-in-place concrete Type I-A construction (residential / amenity / commercial / parking). Enclosed parking garage, elevated courtyards on top podium level, including a pool. +/-375 residential units , . Jason Shepard 770.864.1035XXXX jshepard@dwelldesignstudio.comDwell Design Studio Jordan & Skala Engineers LandDesign B1 - IA ALL USES UNLIMITED -UNLIMITED - 0 0 1 Residential-R2 Residential-R2 - 53,534 17,944 - - - I-A 3 Hr. III-A 2 Hr. 2 Hr. 2 Hr. 1 Hr. Fire Partition 3 Hr. SEE MECHANICAL DRAWINGS - M0.01 374 0 0 * Per 2018 NCSBC 1004.2 Increased Occupant Load 2 0 0 1 110 02 2 20 00 0 SEE ELECTRICAL DRAWINGS - E0.01 SEE STRUCTURAL DRAWINGS - S001 GrossBuilding Area Table BUILDING 1 New (SQ FT) TOTAL ALLOWABLE AREA Primary OccupancyClassification(s): Assembly A-1 A-2 A-3 A-4 A-5 Business Educational Factory F-1 Moderate F-2 Low Hazardous H-1 Detonate H-2 Deflagrate H-3 Combust H-4 Health H-5 HPM Institutional I-1 Condition 1 2 I-2 Condition 1 2 I-3 Condition 1 2 3 4 5 I-4 Mercantile Residential R-1 R-2 R-3 R-4 Storage S-1 Moderate S-2 Low High-piled Parking Garage Open Enclosed Repair Garage Utility and Miscellaneous Accessory Occupancy Classification(s): Incidental Uses(Table 509): Special Uses(Chapter 4 –List Code Sections): SpecialProvisions:(Chapter 5 –List Code Sections): Mixed Occupancy:No Yes Separation: _____ Hr.Exception: _____________________ Non-Separated Use (508.3)- The required type of construction for the building shall be determined by applying the height and area limitations for each of the applicable occupancies to the entire building. The most restrictive type of construction, so determined, shall apply to the entire building. Separated Use (508.4)- See below for area calculations for each story, the area of the occupancy shall be such that the sum of the ratios of the actual floor area of each use divided by the allowable floor area for each use shall not exceed 1. +<1 STORY NO. DESCRIPTION AND USE (A) BLDG AREA PER STORY (ACTUAL ) (B) TABLE 506.24 AREA (C) AREA FOR FRONTAGE INCREASE1,5 (D) ALLOWABLE AREA PER STORY OR UNLIMITED 2,3 1 Frontage area increases from Section 506.2 are computed thus: a.Perimeter which fronts a public way or open space having 20 feet minimum width = _______ (F) b.Total Building Perimeter = ________ (P) c.Ratio (F/P) = ___________(F/P) d.W = Minimum width of public way = ________ (W) e.Percent of frontage increase If = 100[–0.25] x /30 = ________ (%) 2 Unlimited area applicable under conditions ofSection 507. 3 Maximum Building Area = total number of stories in the building x D(maximum 3 stories)(506.2). 4 The maximum area ofopenparking garages must comply withTable406.5.4. The maximum area of air traffic control towers must comply withTable412.3.1 5 Frontage increase is based on the unsprinklered area value in Table 506.2. ALLOWABLE HEIGHT ALLOWABLE SHOWN ON PLANS CODE REF. Building Height in Feet (Table 504.3) Building Height in Stories(Table 504.4) 1 Provide code reference if the “Shown on Plans”quantity is not based on Table 504.3 or 504.4. FIRE PROTECTION REQUIREMENTS BUILDING ELEMENT FIRE SEPARATION DISTANCE (FEET) RATING DETAIL # AND SHEET # DESIGN # FOR RATED ASSEMBLY SHEET # FOR RATED PENETRATION SHEET # FOR RATED JOINTS REQ'D PROVIDED (W/_________* REDUCTION) Structural Frame, including columns, girders, trusses Bearing Walls Exterior Plan North Plan East Plan West Plan South Interior Nonbearing Walls and Partitions Exterior walls North East West South Interior walls and partitions Floor Construction Including supporting beams and joists Floor Ceiling Assembly Columns Supporting Floors Roof Construction, including supporting beams and joists Roof Ceiling Assembly Columns Supporting Roof Shaft Enclosures-Exit Shaft Enclosures-Other Corridor Separation Occupancy/Fire Barrier Separation Party/Fire Wall Separation Smoke Barrier Separation Smoke Partition Tenant/ Dwelling Unit/ Sleeping Unit Separation Incidental Use Separation *Indicate section number permitting reduction PERCENTAGE OF WALL OPENING CALCULATIONS FIRE SEPARATION DISTANCE (FEET)FROM PROPERTY LINES DEGREE OF OPENINGS PROTECTION (TABLE 705.8) ALLOWABLE AREA (%) ACTUAL SHOWN ON PLANS (%) LIFE SAFETY SYSTEM REQUIREMENTS Emergency Lighting: No Yes Exit Signs:No Yes Fire Alarm: No Yes Smoke Detection Systems:No Yes Partial _______ Panic Hardware: No Yes LIFE SAFETY PLAN REQUIREMENTS Life Safety Plan Sheet #: __________________________________ Fire and/or smoke rated wall locations (Chapter 7) Assumed and real property line locations(if not on the site plan) Exterior wall opening area with respect to distance to assumed property lines(705.8) Occupancy Use for each area as it relates to occupant load calculation(Table 1004.1.2) Occupant loads for each area Exit access travel distances (1017) Common path of travel distances (Tables 1006.2.1 & 1006.3.2(1)) Dead end lengths (1020.4) Clear exit widths for each exit door Maximum calculated occupant load capacity each exit door can accommodate based on egress width (1005.3) Actual occupant load for each exit door A separate schematic plan indicating where fire rated floor/ceiling and/or roof structure is provided for purposes of occupancy separation Location of doors with panic hardware (1010.1.10) Location of doors with delayed egress locks and the amount of delay(1010.1.9.7) Location of doors with electromagnetic egress locks (1010.1.9.9) Location of doors equipped with hold -open devices Location of emergency escape windows (1030) The square footage of each fire area (202) The square footage of each smoke compartment for Occupancy Classification I-2 (407.5) Note any code exceptions or table notes that may have been utilized regarding the items above ACCESSIBLE DWELLING UNITS (SECTION 1107) TOTAL UNITS ACCESSIBLE UNITS REQUIRED ACCESSIBLE UNITS PROVIDED TYPE A UNITS REQUIRED TYPE A UNITS PROVIDED TYPE B UNITS REQUIRED TYPE B UNITS PROVIDED TOTAL ACCESSIBLE UNITS PROVIDED ACCESSIBLE PARKING (SECTION 1106) LOT OR PARKING AREA TOTAL #OF PARKING SPACES #OF ACCESSIBLE SPACES PROVIDED TOTAL # ACCESSIBLE PROVIDED REQUIRED PROVIDED REGULAR WITH 5'ACCESS AISLE VAN SPACES WITH 132”ACCESS AISLE 8'ACCESS AISLE TOTAL PLUMBING FIXTURE REQUIREMENTS (TABLE 2902.1) USE WATERCLOSETS URINALS LAVATORIES SHOWERS /TUBS DRINKING FOUNTAINS MALE FEMALE UNISEX MALE FEMALE UNISEX REGULAR ACCESSIBLE SPACE REQUIRED PROVIDED SPECIAL APPROVALS Special approval: _______________________________________________________________________________________ _______________________________________________________________________________________ BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS STRUCTURAL DESIGN (PROVIDE ON THESTRUCTURAL SHEETS IF APPLICABLE) DESIGN LOADS: Importance Factors: Snow (IS)_________ Seismic (IE)_________ Live Loads:Roof _________ psf Mezzanine _________ psf Floor _________ psf Ground Snow Load: _________ psf Wind Load:Basic Wind Speed _________ mph (ASCE-7) Exposure Category _________ SEISMIC DESIGN CATEGORY:A B C D Provide the following Seismic Design Parameters: Risk Category (Table 1604.5)I II III IV Spectral Response Acceleration SS_________ %g S1_________ %g SiteClassification (ASCE 7)A B C D E F Data Source:Field Test Presumptive Historical Data Basic structural system Bearing Wall Dual w/Special Moment Frame Building Frame Dual w/Intermediate R/C or Special Steel Moment Frame Inverted Pendulum Analysis Procedure:Simplified Equivalent Lateral Force Dynamic Architectural, Mechanical, Components anchored?Yes No LATERAL DESIGN CONTR OL:Earthquake Wind SOIL BEARING CAPACIT IES: Field Test (provide copy of test report)___________________psf PresumptiveBearing capacity ___________________psf Pile size, type, and capacity ______________________________________ BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS MECHANICAL DESIGN (PROVIDE ON THE MECHANICAL SHEETSIF APPLICABLE ) MECHANICAL SUMMARY MECHANICAL SYSTEMS, SERVICE SYSTEMS AND EQUIPMENT Thermal Zone winter dry bulb:___________ summer dry bulb:___________ Interior design conditions winter dry bulb:___________ summer dry bulb:___________ relative humidity:___________ Building heating load :___________ Building cooling load:___________ Mechanical Spacing Conditioning System Unitary description of unit:___________ heating efficiency:___________ cooling efficiency:___________ size category ofunit:___________ Boiler Size category. If oversized, state reason.:___________ Chiller Size category. If oversized, state reason.:___________ List equipment efficiencies:___________ BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS ELECTRICAL DESIGN (PROVIDE ON THE ELECTRICAL SHEETSIF APPLICABLE ) ELECTRICAL SUMMARY ELECTRICAL SYSTEM AND EQUIPMENT Method of Compliance: Energy Code Performance Prescriptive ASHRAE 90.1 Performance Prescriptive Lighting schedule (each fixturetype) lamp type required in fixture number of lamps in fixture ballast type used in the fixture number of ballasts in fixture total wattage per fixture total interior wattage specified vsallowed(whole building or space by space) total exterior wattage specified vs .allowed Additional Efficiency Package Options (When using the 2018 NCECC; not required for ASHRAE 90.1) C406.2 More Efficient HVAC Equipment Performance C406.3 Reduced Lighting Power Density C406.4 Enhanced Digital Lighting Controls C406.5 On-Site Renewable Energy C406.6 Dedicated Outdoor Air System C406.7 Reduced Energy Use in Service Water Heating BUILDING CODE SUMMARY FOR ALL COMMERCIAL PROJECTS (EXCEPT 1AND 2-FAMILY DWELLINGS AND TOWNHOUSES) (Reproduce the following data on the building plans sheet 1 or 2) Name of Project:_______________________________________________________________________________ Address:_____________________________________________________________Zip Code_________ Owner/Authorized Agent: ______________Phone #E-Mail _______________ Owned By: City/County Private State Code Enforcement Jurisdiction:City____________ County_________State 2018 BUILDING CODE: New Building Addition Renovation 1stTime Interior Completion Shell/Core-Contact the local inspection jurisdiction for possible additional procedures and requirements Phased Construction - Shell/Core- Contact the local inspection jurisdiction for possible additional procedures and requirements 2018 EXISTING BUILDING CODE: EXISTING: Prescriptive Repair Chapter 14 Alteration:Level I Level II Level III Historic Property Change of Use CONSTRUCTED :(date)__________ CURRENT OCCUPANCY (S)(Ch. 3): RENOVATED :(date)PROPOSEDOCCUPANCY (S)(Ch. 3):________________ OCCUPANCY CATEGORY (Table 1604.5):Current:I II III IV Proposed: I II III IV BASIC BUILDING DATA Construction Type:I-A II-A III-A IV V-A (check all that apply)I-B II-B III-B V-B Sprinklers:No Partial Yes NFPA 13 NFPA 13R NFPA 13D Standpipes:No Yes Class I II III Wet Dry Fire District: No Yes Flood Hazard Area: No Yes Special Inspections Required:No Yes(Contact the local inspection jurisdiction for additional procedures and requirements.) __________ PROJECT DESCRIPTION (Local Jurisdiction, Department of Insurance, OSC, DPI, DHHS, etc., describe below) 2018 APPENDIX B CONTACT : DESIGNER FIRM NAME LICENSE#TELEPHONE #E-Mail Architectural ___________________ _______________ _______ ________________ Civil Electrical Fire Alarm Plumbing Mechanical Sprinkler-Standpipe Structural Retaining Walls >5' High Other (“Other”should include firms and individuals such as truss, precast, pre-engineered, interior designers, etc.) __________ _________________ Landscape ARRANGEMENT MEANS OF EGRESS (SECTION 1015.2) EXIT REQUIREMENTS NUMBER AND ARRANGEMENT OF EXITS SHOWN ON PLANS FLOOR, ROOM OR SPACE DESIGNATION 2 1,3 Life Safety Plan Sheet #: MINIMUMNUMBER OF EXITS REQUIRED T1021.2 ACTUAL DISTANCE SHOWN ON PLANS REQUIRED DISTANCE BETWEEN EXIT DOORS ALLOWABLE TRAVEL DISTANCE (TABLE 1017.2) ACTUAL TRAVEL DISTANCE SHOWN ON PLANS TRAVEL DISTANCE Common Path of Travel (Section 1014.3) Buildings with Single Exits (Table 1021.2), Spaces with one means of egress (Table 1015.1) Corridor Dead Ends (Section 1018.4) 2 3 1 See Table 1004.1.1 to determine whether net or gross area is applicable. See definition "Area, Gross" and "Area, Net" (Section 1002). LEVEL OCCUPANT LOAD AND EXIT WIDTH USE GROUP OR SPACE DESCRIPTION 1 (a) AREA (SF) STAIR 1 (b) AREA PER OCCUPANT (Table 1004.1.1) LEVEL (c)EXIT WIDTH (in) STAIR LEVEL STAIR 2,3,4,5,6 1 2 ACTUAL WIDTH SHOWN ON PLANS EGRESS WIDTH PER OCCUPANT (Table 1005.1) REQUIRED WIDTH (Section 1005.1) (a / b) x c Minimum stairway width (Section 1009.1); minimum corridor width (Section 1018.2); minimum door width (Section 1008.1.1) The loss of one means of egress shall not reduce the available capacity to less than 50 percent of the total required (Section 1005.1) Minimum width of exit passageway (Section 1023.2) Assembly Occupancies (Section 1028) 5 6 3 4 CALCULATED OCCUPANT LOAD (a / b) See Section 1004.5 for converging exits. 7 Spaces within occupancies or use groups shall be calculated independently. (Ex. lobbies, lounges, break rooms, conference rooms)7 Life Safety Plan Sheet #: ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ___________________ _______________ _______ __________________________ ________________ + = 0.28 A0.04 & A0.05 A0.04 & A0.05 A0.04 & A0.05 Schedule of Special Inspection Services Exterior Insulation and Finish Systems (EIFS) Verify that EIFS is installed in conformance with project specifications If a water resistive barrier coating complying with ASTM E2570 is installed over a sheathing substrate, verify that the water-barrier and drainage strip are installed in conformance with the project specifications. Inspection Task Task Req'd Freq Reference for Criteria Standard NCBC Agent P P 1705.16 1705.16.1 1 2 ______________ Justin Houston Jordan & Skala Engineers Jordan & Skala Engineers Jordan & Skala Engineers Jordan & Skala Engineers Seven24 Consulting, Inc. LandDesign 28202 1 17,983 sf Open to Below 17,944 sf 17,944 sf LEVEL 1 LEVEL 2 LEVEL 3-5 LEVEL 6 LEVEL 7-10 New (SQ FT) 20,266 sf 53,168 sf 72,810 sf 72,810 sf 53,534 sf BUILDING 2 LEVEL 1 LEVEL 2 LEVEL 3-5 LEVEL 6-8 578,810 sf Subtotal 20,266 sf 53,168 sf 218,430 sf 72,810 sf 214,136 sf 125,647 sf 17,983 sf Open to Below 53,832 sf 53,832 sf Subtotal B2 - IA UNLIMITED UNLIMITED B1 - IIIA B2 - IIIA 96,000 96,000 B2 ACT 82' / AGP 75' 5 / 5 SEE AREA CALCULATIONS THIS PAGE 288,000 B1-IIIA = 286,946 11 11 ALL REMAINING 363 11 10<X< 30 / >30'-0" >30'-0" >30'-0" >30'-0" 1 Hr. / 0 Hr. 0 Hr. 0 Hr. 0 Hr. 10<X< 30 / >30'-0" 1 Hr. / 0 Hr. I-A 3 Hr. III-A 1 Hr. I-A 3 Hr. III-A 1 Hr. I-A 2 Hr. III-A 1 Hr. I-A 1.5 Hr. III-A 1 Hr. 1 Hr. Section 510.2 Section 510.5 403-High Rise Buildings, 420-Group R-2 Section 708.3 Section 708.7 Section 708.8 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:23:59 PM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA00.12 2247601 BUILDING CODE SUMMARY - APPENDIX B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCBUILDING GROSS AREA TABLE BUILDING NUMBER LEVEL USE GROUP FUNCTION AREA PHASE 1 BUILDING 1 - TYPE I-A LEVEL 1 M RETAIL/COMMERCIAL 20,044 SF BUILDING 1 - TYPE I-A LEVEL 2 S-2 PARKING 52,429 SF BUILDING 1 - TYPE I-A LEVEL 2 OPEN TO BELOW 19,657 SF BUILDING 1 - TYPE I-A LEVEL 3 S-2 PARKING 52,427 SF BUILDING 1 - TYPE I-A LEVEL 3 R-2 RESIDENTIAL 20,207 SF BUILDING 1 - TYPE I-A LEVEL 4 S-2 PARKING 52,427 SF BUILDING 1 - TYPE I-A LEVEL 4 R-2 RESIDENTIAL 20,207 SF BUILDING 1 - TYPE I-A LEVEL 5 S-2 PARKING 52,433 SF BUILDING 1 - TYPE I-A LEVEL 5 R-2 RESIDENTIAL 20,336 SF 310,167 SF BUILDING 1 - TYPE III-A LEVEL 6 R-2 RESIDENTIAL 56,967 SF BUILDING 1 - TYPE III-A LEVEL 7 R-2 RESIDENTIAL 57,328 SF BUILDING 1 - TYPE III-A LEVEL 8 R-2 RESIDENTIAL 57,236 SF BUILDING 1 - TYPE III-A LEVEL 9 R-2 RESIDENTIAL 57,273 SF BUILDING 1 - TYPE III-A LEVEL 10 R-2 RESIDENTIAL Not Enclosed 228,803 SF PHASE 2 BUILDING 2 - TYPE I-A LEVEL 1 M RETAIL/COMMERCIAL 16,122 SF BUILDING 2 - TYPE I-A LEVEL 2 OPEN TO BELOW 16,148 SF BUILDING 2 - TYPE I-A LEVEL 3 R-2 RESIDENTIAL 17,444 SF BUILDING 2 - TYPE I-A LEVEL 4 R-2 RESIDENTIAL 18,702 SF BUILDING 2 - TYPE I-A LEVEL 5 R-2 RESIDENTIAL 18,967 SF 87,383 SF BUILDING 2 - TYPE III-A LEVEL 6 R-2 RESIDENTIAL 18,737 SF BUILDING 2 - TYPE III-A LEVEL 7 R-2 RESIDENTIAL 18,758 SF BUILDING 2 - TYPE III-A LEVEL 8 R-2 RESIDENTIAL 18,753 SF 56,247 SF TOTAL GROSS BUILDING AREA 682,600 SF GROSS BUILDING - AMENITY EXTERIOR BLDG NUMBER Level Area Use Area PHASE 1 BUILDING 1 - TYPE III-A LEVEL 6 AMENITIES - EXTERIOR 14,330 SF GROSS BUILDING - PARKING DECK BLDG NUMBER Level Area Use Area PHASE 1 BUILDING 1 - TYPE I-A LEVEL 2 PARKING 52,429 SF BUILDING 1 - TYPE I-A LEVEL 3 PARKING 52,427 SF BUILDING 1 - TYPE I-A LEVEL 4 PARKING 52,427 SF BUILDING 1 - TYPE I-A LEVEL 5 PARKING 52,433 SF 209,715 SF GROSS BUILDING - RESIDENTIAL AREA BLDG NUMBER Level Area Use Area PHASE 1 BUILDING 1 - TYPE I-A LEVEL 3 RESIDENTIAL 20,207 SF BUILDING 1 - TYPE I-A LEVEL 4 RESIDENTIAL 20,207 SF BUILDING 1 - TYPE I-A LEVEL 5 RESIDENTIAL 20,336 SF BUILDING 1 - TYPE III-A LEVEL 6 RESIDENTIAL 56,967 SF BUILDING 1 - TYPE III-A LEVEL 7 RESIDENTIAL 57,328 SF BUILDING 1 - TYPE III-A LEVEL 8 RESIDENTIAL 57,236 SF BUILDING 1 - TYPE III-A LEVEL 9 RESIDENTIAL 57,273 SF BUILDING 1 - TYPE III-A LEVEL 10 RESIDENTIAL 0 SF 289,553 SF PHASE 2 BUILDING 2 - TYPE I-A LEVEL 3 RESIDENTIAL 17,444 SF BUILDING 2 - TYPE I-A LEVEL 4 RESIDENTIAL 18,702 SF BUILDING 2 - TYPE I-A LEVEL 5 RESIDENTIAL 18,967 SF BUILDING 2 - TYPE III-A LEVEL 6 RESIDENTIAL 18,737 SF BUILDING 2 - TYPE III-A LEVEL 7 RESIDENTIAL 18,758 SF BUILDING 2 - TYPE III-A LEVEL 8 RESIDENTIAL 18,753 SF 111,361 SF 400,913 SF GROSS BUILDING - RETAIL/COMMERCIAL BLDG NUMBER Level Area Use Area PHASE 1 BUILDING 1 - TYPE I-A LEVEL 1 RETAIL/COMMERCIAL 20,044 SF PHASE 2 BUILDING 2 - TYPE I-A LEVEL 1 RETAIL/COMMERCIAL 16,122 SF 36,166 SF DATE DESCRIPTION REV GEN F. D. C.F. D. C. 3-HR HORIZONTAL SEPARATION 3-HR SEPARATION PHASE 1 5 STORIES TYPE I-A S-2 PARKING GARAGE NFPA 13 FULLY SPRINKLERED PHASE 1 5 STORIES TYPE III-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 1 5 STORIES TYPE III-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLEREDPHASE 2 5 STORIES TYPE III-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 2 3 STORIES TYPE I-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 2 TYPE I-A M RETAIL NFPA 13 FULLY SPRINKLERED 837 1/8" FIRE SEPARATION DISTANCE PHASE 1 5 STORIES TYPE III-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 1 5 STORIES TYPE III-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 1 4 STORIES TYPE I-A S-2 PARKING GARAGE NFPA 13 FULLY SPRINKLERED 699 1/4" FIRE SEPARATION DISTANCE PHASE 1 5 STORIES TYPE III-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 1 5 STORIES TYPE III-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 1 4 STORIES TYPE I-A S-2 PARKING GARAGE NFPA 13 FULLY SPRINKLERED PHASE 2 5 STORIES TYPE III-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 2 3 STORIES TYPE I-A R-2 RESIDENTIAL NFPA 13 FULLY SPRINKLERED PHASE 2 TYPE I-A M RETAIL NFPA 13 FULLY SPRINKLERED 3-HR HORIZONTAL SEPARATION 1 A00.13 1 A00.13 2 A00.13 2 A00.13 3 A00.13 3 A00.13 4 A00.13 4 A00.13 SOUTH CEDAR STREET STADIUM VIEW DRIVESETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ONEXISTING BUILDING EXISTING BUILDING EXISTING BUILDING C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:54:21 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.13 2247601 IBC CODE DATA - BUILDING SECTIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1" = 20'-0"1 BUILDING OCCUPANCY / FIRE RATING SECTION 1 1" = 20'-0"2 BUILDING OCCUPANCY / FIRE RATING SECTION 2 1" = 20'-0"3 BUILDING OCCUPANCY / FIRE RATING SECTION 3 1" = 20'-0"4 BUILDING OCCUPANCY / FIRE RATING SECTION 4 1" = 50'-0"5 CODE DATA KEY PLAN DATE DESCRIPTION REV 1-HOUR RATED WALL 2-HOUR RATED WALL LIFE SAFETY LEGEND TEMPORARY 2-HR RATED WALL (TO BE REMOVED UPON COMPLETION OF ADJACENT PHASE) LIFE SAFETY NOTES ARROW INDICATES EGRESS POINT FROM BUILDING FEC FIRE EXTINGUISHER CABINET WITH 75' MAX TRAVEL DISTANCE EGRESS EXIT SIGNAGE -WITH DIRECTIONAL ARROW AS NEEDED. MAX VIEWING DISTANCE = 100 FEET 3-HOUR RATED WALL 45 MINUTE RATED EGRESS DOOR 90 MINUTE RATED EGRESS DOOR 180 MINUTE RATED EGRESS DOOR A. FOR CLARITY, PRINT ALL CODE DATA SHEETS IN COLOR. B. OCCUPANT LOADS FOR FUTURE BUILDINGS ARE SHOWN TO ILLUSTRATE COMPLIANCE FOR EGRESS WIDTHS IN THE STAIRS. C. COURTYARD ACCESS DOOR FROM POOL COURTYARD WITH KEY CARD ACCESS AT 45" A.F.F. AND MAGNETIC LOCK TO DISENGAGE UPON FIRE ALARM ACTIVATION PER NFPA 101.7.2.1.6.2. D. PROVIDE 48" HIGH PATIO GUARDRAILS WITH VERTICAL PICKETS FOR ALL UNITS FACING POOL/POOL DECK AT FIRST FLOOR ONLY. E. WINDOWS AT DWELLING UNITS FACING POOL/POOL DECK WILL BE PINNED SO AS NOT TO OPEN MORE THAN 4" AT FIRST FLOOR ONLY. 75' MAX 20 MINUTE RATED EGRESS DOOR (PER IBC TABLE 716.5) AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 7,344 SF 123 OCC BUILDING 2 -TYPE I-A 60 SF / OCC M AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 2,591 SF 44 OCC BUILDING 1 -TYPE I-A 60 SF / OCC M AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 4,348 SF 290 OCC BUILDING 1 -TYPE I-A 15 SF / OCC A-2 AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 812 SF 3 OCC BUILDING 1 -TYPE I-A 300 SF / OCC U AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 546 SF 2 OCC BUILDING 1 -TYPE I-A 300 SF / OCC U LIFE SAFETY PLAN LEGEND AMENITIES - INTERIOR BUSINESS - LEASING CORE RESTAURANT RETAIL AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 5,558 SF 371 OCC BUILDING 2 -TYPE I-A 15 SF / OCC A-2 AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 1,494 SF 5 OCC BUILDING 2 -TYPE I-A 300 SF / OCC S-2 AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 692 SF 7 OCC BUILDING 1 -TYPE I-A 100 SF / OCC B DIAGONAL DISTANCE = 129' -10" DIAGONAL DISTANCE = 105' -10" DIAGONAL DISTANCE = 89' -11" SERVICE CORRIDOR MAIL ROOM LEASING/LOBBY RETAIL RETAIL RETAIL TRASH RESTAURANT TRASH DISTANCE BETWEEN EXITS = 65' -11" DISTANCE BETWEEN EXITS = 68' -0" TRAVEL DISTANCE = 161' -11" DISTANCE BETWEEN EXITS = 119' -10" TRAVEL DISTANCE = 58' -11" TRAVEL DISTANCE = 95' -3" MAXIMUM ALLOWED = 250' -0" TRAVEL DISTANCE = 94' -9" MAXIMUM ALLOWED = 250' -0" TRAVEL DISTANCE = 91' -0" MAXIMUM ALLOWED = 250' -0" TRAVEL DISTANCE = 113' -7" MAXIMUM ALLOWED = 250' -0" 44 OCCUPANTS 44 OCC.(RETAIL) DOOR = 0.2 X 44 = 8.8" (34" PROVIDED) 44 OCCUPANTS 44 OCC.(RETAIL) DOOR = 0.2 X 44 = 8.8" (68" PROVIDED) 46 OCCUPANTS 46 OCC.(RETAIL) DOOR = 0.2 X 46 = 9.2" (68" PROVIDED) 46 OCCUPANTS 46 OCC.(RETAIL) DOOR = 0.2 X 46 = 9.2" (68" PROVIDED) 46 OCCUPANTS 46 OCC.(RETAIL) DOOR = 0.2 X 46 = 9.2" (68" PROVIDED) 129 OCCUPANTS 129 OCC.(RESTAURANT) DOOR = 0.2 X 129 = 25.8" (68" PROVIDED) 129 OCCUPANTS 129 OCC.(RESTAURANT) DOOR = 0.2 X 129 = 25.8" (34" PROVIDED) AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 1,830 SF 19 OCC BUILDING 1 -TYPE I-A 100 SF / OCC B AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 427 SF 29 OCC BUILDING 1 -TYPE I-A 15 SF / OCC A-3 AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 1 4,861 SF 49 OCC BUILDING 1 -TYPE I-A 100 SF / OCC B C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:54:27 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.30 2247601 LIFE SAFETY PLAN -LEVEL 1 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LIFE SAFETY PLAN - LEVEL 1 AREA SCHEDULE - LEVEL 1 AREA NAME USE GROUP AREA LOAD FACTOR OCCUPANTS BUILDING 1 - TYPE I-A RESTAURANT A-2 4,348 SF 15 SF 365 CIRCULATION A-3 427 SF 15 SF LEASING/LOBBY B 4,861 SF 100 SF 48 MAIL ROOM B 692 SF 100 SF 7 RESTAURANT KITCHEN B 1,830 SF 100 SF 19 RETAIL M 2,591 SF 60 SF 56 BOH U 812 SF 300 SF 3 BOH U 546 SF 300 SF 1 16,106 SF 499 BUILDING 2 - TYPE I-A RESTAURANT A-2 5,558 SF 15 SF 397 RETAIL M 7,344 SF 60 SF 138 TRASH S-2 1,494 SF 300 SF 7 14,396 SF 542 DATE DESCRIPTION REV AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 Not Enclosed 0 OCC BUILDING 1 -TYPE III-A 200 SF / OCC R-2 AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 1,469 SF 98 OCC BUILDING 1 -TYPE III-A 15 SF / OCC A-3 LIFE SAFETY PLAN LEGEND AMENITIES - EXTERIOR AMENITIES - INTERIOR CORE RESIDENTIAL COURTYARD A AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 3,761 SF 251 OCC BUILDING 1 -TYPE III-A 15 SF / OCC A-3 AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 2,897 SF 194 OCC BUILDING 1 -TYPE III-A 15 SF / OCC A-3 AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 724 SF 49 OCC BUILDING 1 -TYPE III-A 15 SF / OCC A-3 DIAGONAL DISTANCE = 94' -4" DISTANCE BETWEEN EXITS = 100' -11" DIAGONAL DISTANCE = 147' -11" TRAVEL DISTANCE = 145' -8" MAXIMUM ALLOWED = 250' -0" AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 18,194 SF 91 OCC BUILDING 2 -TYPE III-A 200 SF / OCC R-2 COURTYARD B COURTYARD C DISTANCE BETWEEN EXITS = 199' -2" DIAGONAL DISTANCE = 474' -1" DISTANCE BETWEEN EXITS = 158' -0" DISTANCE BETWEEN EXITS = 75' -9" DIAGONAL DISTANCE = 234' -10" AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 600 SF 13 OCC BUILDING 1 -TYPE III-A 50 SF / OCC A-4 POOL TRAVEL DISTANCE = 172' -9" MAXIMUM ALLOWED = 250' -0" AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 900 SF 61 OCC BUILDING 1 -TYPE III-A 15 SF / OCC A-4 97 OCCUPANTS 97 OCC.(COURTYARD B) DOOR = 0.2 X 97 = 19.4" (34" PROVIDED) 97 OCCUPANTS 97 OCC.(COURTYARD B) DOOR = 0.2 X 97 = 19.4" (34" PROVIDED) 49 OCCUPANTS 49 OCC.(COURTYARD C) DOOR = 0.2 X 49 = 9.8" (34" PROVIDED) 126 OCCUPANTS 126 OCC.(COURTYARD A) DOOR = 0.2 X 126 = 25.2" (34" PROVIDED) 126 OCCUPANTS 126 OCC.(COURTYARD A) DOOR = 0.2 X 126 = 25.2" (34" PROVIDED) TRAVEL DISTANCE = 161' -7" MAXIMUM ALLOWED = 250' -0" TRAVEL DISTANCE = 65' -5" MAXIMUM ALLOWED = 250' -0" TRAVEL DISTANCE = 190' -11" MAXIMUM ALLOWED = 250' -0" TRAVEL DISTANCE = 190' -2" MAXIMUM ALLOWED = 250' -0" TRAVEL DISTANCE = 189' -5" MAXIMUM ALLOWED = 250' -0" TRAVEL DISTANCE = 182' -0" MAXIMUM ALLOWED = 250' -0" DIAGONAL DISTANCE = 63' -10" DISTANCE BETWEEN EXITS = 43' -0" AMENITY JAN ELEC ROOM TRASH TRAVEL DISTANCE = 79' -11" MAXIMUM ALLOWED = 125' -0" WITHIN DWELLING UNIT TRAVEL DISTANCE = 97' -7" MAXIMUM ALLOWED = 125' -0" WITHIN DWELLING UNIT TRAVEL DISTANCE = 177' -10" MAXIMUM ALLOWED = 250' -0" FITNESS AREA:OCCUPANCY TYPE: OCC CALC:TOTAL # OCCUPANTS: LEVEL 6 1,264 SF 13 OCC BUILDING 1 -TYPE III-A 100 SF / OCC B 1-HOUR RATED WALL 2-HOUR RATED WALL LIFE SAFETY LEGEND TEMPORARY 2-HR RATED WALL (TO BE REMOVED UPON COMPLETION OF ADJACENT PHASE) LIFE SAFETY NOTES ARROW INDICATES EGRESS POINT FROM BUILDING FEC FIRE EXTINGUISHER CABINET WITH 75' MAX TRAVEL DISTANCE EGRESS EXIT SIGNAGE -WITH DIRECTIONAL ARROW AS NEEDED. MAX VIEWING DISTANCE = 100 FEET 3-HOUR RATED WALL 45 MINUTE RATED EGRESS DOOR 90 MINUTE RATED EGRESS DOOR 180 MINUTE RATED EGRESS DOOR A. FOR CLARITY, PRINT ALL CODE DATA SHEETS IN COLOR. B. OCCUPANT LOADS FOR FUTURE BUILDINGS ARE SHOWN TO ILLUSTRATE COMPLIANCE FOR EGRESS WIDTHS IN THE STAIRS. C. COURTYARD ACCESS DOOR FROM POOL COURTYARD WITH KEY CARD ACCESS AT 45" A.F.F. AND MAGNETIC LOCK TO DISENGAGE UPON FIRE ALARM ACTIVATION PER NFPA 101.7.2.1.6.2. D. PROVIDE 48" HIGH PATIO GUARDRAILS WITH VERTICAL PICKETS FOR ALL UNITS FACING POOL/POOL DECK AT FIRST FLOOR ONLY. E. WINDOWS AT DWELLING UNITS FACING POOL/POOL DECK WILL BE PINNED SO AS NOT TO OPEN MORE THAN 4" AT FIRST FLOOR ONLY. 75' MAX 20 MINUTE RATED EGRESS DOOR (PER IBC TABLE 716.5)C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:54:49 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.35 2247601 LIFE SAFETY PLAN -LEVEL 6 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LIFE SAFETY PLAN - LEVEL 6 AREA SCHEDULE - LEVEL 6 AREA NAME USE GROUP AREA LOAD FACTOR OCCUPANTS BUILDING 1 - TYPE III-A AMENITY A-3 1,469 SF 15.00 SF 98 COURTYARD A A-3 3,761 SF 15.00 SF 251 COURTYARD B A-3 2,897 SF 15.00 SF 194 COURTYARD C A-3 724 SF 15.00 SF 49 POOL A-4 600 SF 50.00 SF 13 POOL DECK A-4 900 SF 15.00 SF 61 FITNESS B 1,264 SF 100.00 SF 13 LEVEL 6 R-2 Not Enclosed 200.00 SF 273 BOH U 21 SF 300.00 SF 1 BOH U Not Enclosed 300.00 SF 1 BOH U 21 SF 300.00 SF 1 BOH U 21 SF 300.00 SF 1 BOH U 21 SF 300.00 SF 1 BOH U 21 SF 300.00 SF 1 BOH U 21 SF 300.00 SF 1 BOH U 21 SF 300.00 SF 1 BOH U 21 SF 300.00 SF 1 BOH U 222 SF 300.00 SF 1 BOH U 66 SF 300.00 SF 1 BOH U 255 SF 300.00 SF 1 ELECTRICAL U 105 SF 300.00 SF 1 12,431 SF 965 BUILDING 2 - TYPE III-A LEVEL 6 R-2 18,194 SF 200.00 SF 91 BOH U 19 SF 300.00 SF 1 BOH U 61 SF 300.00 SF 1 BOH U 26 SF 300.00 SF 1 BOH U 92 SF 300.00 SF 1 BOH U 54 SF 300.00 SF 1 BOH U 47 SF 300.00 SF 1 BOH U 26 SF 300.00 SF 1 BOH U 51 SF 300.00 SF 1 18,571 SF 99 DATE DESCRIPTION REV 48"30"60"30"48"30"1' - 6" LINE OF CLEAR FLOOR SPACE DIRECTION OF TRAVEL DIRECTION OF TRAVEL 56" MIN CLEAR60" MIN CLEAR24" MAX.LINE OF CLEAR FLOOR SPACE DIRECTION OF TRAVEL LAVATORY OR ANY OTHER FIXTURE OR WING WALL MAY NOT PROJECT MORE THAN 24" INTO ROOM(TYP) 15" MIN 1' - 6" 33" MIN CLEAR 48" MIN CLEAR 56" MIN CLEAR15" MIN 1' - 6" LINE OF CLEAR FLOOR SPACE LAVATORY OR ANY OTHER FIXTURE OR WING WALL MAY NOT PROJECT MORE THAN 24" INTO ROOM(TYP) DIRECTION OF TRAVEL DIRECTION OF TRAVEL 48" MIN CLEAR 66" MIN CLEAR24" MAXFRONT AND SIDE APPROACH WITH SIDE OBSTRUCTION SIDE APPROACH WITH SIDE OBSTRUCTION FRONT AND SIDE APPROACH WITHOUT SIDE OBSTRUCTION 33" MIN. CLEAR BACK WALL HEADFOOT (CONTROL)LINE OF CLEAR FLOOR SPACE15" MINLAVATORY W/ KNEE SPACE BELOW DIRECTION OF TRAVEL 19" MAX BACK WALL HEADFOOT(CONTROL)LINE OF CLEAR FLOOR SPACE BACK WALL HEADFOOT(CONTROL)LINE OF CLEAR FLOOR SPACE 30" MIN DIRECTION OF TRAVEL1' - 3"18" MIN33" MIN48" MIN CLEAR60" CLEAR MIN SPECIFICATION "B" BATHROOM SPECIFICATION "A" BATHROOM SPECIFICATION "A" BATHROOM 48" MIN CLEAR 30" MIN CLEAR60" MIN. CLEAR30" MIN. CLEAR1' - 6"1' - 6" 18" MIN 12" MIN HORIZONTAL 2X WD. BLOCKING SHOWN SHADED (TYP) PROPOSED 24" GRAB BAR (TYP) PROPOSED FOLDING GRAB BAR (TYP) NOTE:GRAB BARS SHOWN ARE TO REPRESENT ADAPTIVE DESIGN INTENT ONLY AND ARE NOT REQUIRED TO BE INSTALLED AT TIME OF CONSTRUCTION 1' - 3 3/4"PREFERRED30" MAX32" MAX38" MIN.1' - 6"12" MIN 34" AFF1' - 6" MIN. AREA OF BLOCKING SHOWN HATCHED(TYP) WHERE APPLICABLE PROPOSED 24" GRAB BAR, (TYP) ADDITIONAL 2" RECOMMENDED REINF. AREA SHOWN SHADED12" PREFERREDFLOOR LINE PROPOSED FOLDING GRAB BAR (TYP) TRANSFER SIDE FRONT ELEVATION PLAN NOTE:IN SUCH CASES WHERE A SIDE WALL IS NOT PRESENT, OR INADEQUATE ACCOMMODATION FOR MINIMUM SIDE WALL BLOCKING REQUIREMENTS HAVE BEEN PROVIDED, REFER TO DETAIL 4 OF THIS SHEET FOR ALTERNATIVE W.C. REAR WALL BLOCKING REQUIREMENTS NOTE:GRAB BARS SHOWN ARE TO REPRESENT ADAPTIVE DESIGN INTENT ONLY AND ARE NOT REQUIRED TO BE INSTALLED AT TIME OF CONSTRUCTION 42" PREFERRED24" MIN12" MIN 12" MIN PROPOSED 24" GRAB BAR (TYP.) HORIZONTAL 2X WD. BLOCKING SHOWN SHADED, TYP. 1' - 6" CL 30" MAX. PREFERRED32" MAX.38" MIN.24" MIN12" MAX 34" AFFMIN. AREA OF BLOCKING SHOWN HATCHED (TYP) WHERE APPLICABLE PROPOSED 24" GRAB BAR, (TYP) ADDITIONAL 2" TO 4" RECOMMENDED REINFORCING AT SIDES AND BOTTOM FLOOR LINE 42" PREFERRED PREFERRED30" MAX32" MAX38" MIN.12" MIN 12" MIN 34" AFF1' - 6" MIN. AREA OF BLOCKING SHOWN HATCHED(TYP) WHERE APPLICABLE PROPOSED 24" GRAB BAR, (TYP) ADDITIONAL 2" RECOMMENDED REINF. AREA SHOWN SHADED SIDE ELEVATION FRONT ELEVATION PLAN NOTE:IN SUCH CASES WHERE A SIDE WALL IS NOT PRESENT, OR INADEQUATE ACCOMMODATION FOR MINIMUM SIDE WALL BLOCKING REQUIREMENTS HAVE BEEN PROVIDED, REFER TO DETAIL 4 OF THIS SHEET FOR ALTERNATIVE W.C. REAR WALL BLOCKING REQUIREMENTS NOTE:GRAB BARS SHOWN ARE TO REPRESENT ADAPTIVE DESIGN INTENT ONLY AND ARE NOT REQUIRED TO BE INSTALLED AT TIME OF CONSTRUCTION 12"42" PREFERRED24" MIN12" MIN 12" MIN PROPOSED 24" GRAB BAR (TYP.) HORIZONTAL 2X WD. BLOCKING SHOWN SHADED, TYP. 1' - 6" CL 30" MAX. PREFERRED32" MAX.38" MIN.24" MIN12" MAX 34" AFFMIN. AREA OF BLOCKING SHOWN HATCHED (TYP) WHERE APPLICABLE PROPOSED 24" GRAB BAR, (TYP) ADDITIONAL 2" TO 4" RECOMMENDED REINFORCING AT SIDES AND BOTTOM FLOOR LINE 42" PREFERRED PREFERRED30" MAX32" MAX38" MIN.12" MIN 12" MIN 34" AFF1' - 6" MIN. AREA OF BLOCKING SHOWN HATCHED(TYP) WHERE APPLICABLE PROPOSED 24" GRAB BAR, (TYP) ADDITIONAL 2" RECOMMENDED REINF. AREA SHOWN SHADED SIDE ELEVATION FRONT ELEVATION PLAN PROPOSED 24" GRAB BAR, (TYP) HORIZONTAL BLOCKING FOR REINFORCEMENT AREA OF GRAB BARS SHOWN HATCHED (TYP.) NOTE:GRAB BARS SHOWN ARE TO REPRESENT ADAPTIVE DESIGN INTENT ONLY AND ARE NOT REQUIRED TO BE INSTALLED AT TIME OF CONSTRUCTION HEAD BACK WALL FOOT (CONTROL)PER FHADM. 6.938" MIN.6" MAX.0' - 9"34" AFF24" MAX 12" MAX 6" MAX.48" MIN.6" MAX 24" MIN HEAD0' - 2"0' - 4" 2' - 0"0' - 9"34" AFF38" MIN30" MAX PREFERRED32" MAX.ADDITIONAL RECOMMENDED REINF. AREA SHOWN SHADED HORIZONTAL BLOCKING FOR REINF. AREA OF GRAB BARS SHOWN HATCHED(TYP.) PROPOSED 24" GRAB BAR, (TYP) NOTE:GRAB BAR AT HEAD SIDE OF TUB CAN BE OMITTED IF A BUILT IN TRANSFERSEAT IS PROVIDED 0' - 2"2' - 0"0' - 8" 0' - 4" 24" MIN 0' - 9"34" AFF38" MIN30" MAX PREFERRED32" MAX.ADDITIONAL RECOMMENDED REINF. AREA SHOWN SHADED HORIZONTAL BLOCKING FOR REINF. AREA OF GRAB BARS SHOWN HATCHED(TYP.) PROPOSED 24" GRAB BAR, (TYP) FOOT (CONTROL WALL)54" MAX54" MAX9" MINCLOTHES HANGER ROD (TYP.) HANGER RODS MAY BE ADJUSTABLE WITHIN THIS RANGE (TYP). 2X4 WD. STUD WALLS (TYP.) SHELVES MAY BE ADJUSTABLE WITHIN THIS RANGE (TYP.) SEE DETAILS FOR SHELVING TYPE15" MIN.OPERABLE PARTS48" MAX. TO TOP OF HIGHESTFLOOR LINE RECEPTACLE (TYP.) DIRECTION OF TRAVEL SWITCHES/THERMOSTAT (TYP.) (30" C.F.S. PERP. TO WALL)TO THE LOWESTOPERABLE PARTS2' - 3"FLOOR LINE 4" MAX. PROJECTION FOR OBJECTS HIGHER THAN 27" (TYP.) THAN 27" (TYP.) PROTRUDING OBJECTS LESS THAN 27" ARE DETECTABLE (TYP.) IF THE ACCESSIBLE ROUTE IS REDUCED TO LESS THAN 36", THE WALL HUNG OBJECT CANNOT BE WIDER THAN 24" MAX. (TYP.) 32" MIN SECURITY SIGHTS (PEEPHOLES). IF PROVIDED, SHALL BE LOCATED @ 44" MAX. A.F.F FOR H.C. UNITS & 60" A.F.F FOR ALL OTHERS (TYP.) LEVER TYPE DOOR HANDLEDOOR (SEE DOOR SCHEDULE)44" MAX60".1/2" MAX CURB BEVELED AT 1:2 RECOMMENDEDFINISHED CLEAR DIMENSION36" MINOPTIONAL SHOWER SEAT FINISHED CLEAR DIMENSION 36" MIN HORIZONTAL 2X WOOD BLOCKING PROVIDE REINFORCING FOR OPTIONAL SEAT WHEN THE SHOWER IS THE ONLY BATHING FIXTURE. REINFORCING MUST RUN THE FULL WIDTH OF THE STALL, STARTING AT THE FLOOR TO A HEIGHT OF 24". FHADM 1998, REQ. 6, PG. 6.13 PROVIDE WALL REINFORCEMENT THE FULL LENGTH OF THE WALL BETWEEN 32" MAX. AFF AND 38" MIN. AFF PER FHADM 1998 REQ. 6, PG. 6.12 48" MIN30" MINPROJECT SHALL COMPLY WITH THE FAIR HOUSING AMENDMENTS ACT OF 1998. THE FOLLOWING REQUIREMENTS ARE TO BE COMPLIED WITH. THIS INCLUDES SITE ACCESSIBILITY, PUBLIC AND COMMON USE SPACES AND GROUND FLOOR UNITS OF NON-ELEVATED BUILDINGS. THE REQUIREMENTS LISTED HEREIN ARE BASED ON ANSI A117.1-2009. DWELLING UNITS AND H.U.D. PROPOSED GUIDELINES (24 CFR CHAPTER 1 - FEDERAL REGISTER, FINAL FAIR HOUSING ACCESSIBILITY GUIDELINES-MODIFIED AUGUST 1996) SITE: 1. ACCESSIBLE ROUTES:PROVIDE TO BUILDING ENTRIES, COMMON USE SPACES AND FACILITIES, ROUTES TO COMPLY WITH THE REQUIREMENTS NOTED ON THE CIVIL AND LANDSCAPE PLANS, TYP. --ALL BUILDINGS MUST HAVE AT LEAST ONE ACCESSIBLE ROUTE, UNLESS IT IS EXEMPTED BY THE SITE ANALYSIS TEST DEEMING IT IMPRACTICAL --SHOWN ON ARCHITECTURAL SITE PLAN. 2. COMMON USE FACILITIES: A. BUILDING, MAIL KIOSKS, EXERCISE/ LAUNDRY FACILITIES, COMPACTORS, ETC., PUBLIC AND COMMON USE SPACES MUST BE READILY ACCESSIBLE TO AND USABLE BY PEOPLE WITH DISABILITIES. FEDERAL, STATE, AND LOCAL MUNICIPAL REGULATIONS AND ANSI A117.1-1998 STANDARDS. PROVIDE FOR A CLEAR OPENING OF 32" WIDE (ANSI 404.2.3). CORRIDORS AND PASSAGEWAYS SHALL HAVE A MINIMUM CLEAR WIDTH OF 3'-0" (36), AND MINIMUM CLEAR HEAD ROOM OF 6'-8" (80") WITH CLOSES PROVIDED MUST HAVE A SAFE SWEEP PERIOD PER ANSI 404.2.8 B. DEAD BOLT LOCKS AND LEVER HARDWARE PER ANSI 404.2.7 SHALL BE LOCATED AT THE ENTRY DOOR TO THE UNIT AT A HEIGHT NO HIGHER THAN 48" A.F.F. DOOR SECURITY VIEWERS (PEEPHOLES) ARE TO BE PLACED AT A HEIGHT OF 44" MAX A.F.F. IN THE CENTER OF THE DOOR AT H.C. UNITS AND 60" A.F.F IN ALL OTHER TYP. DOORS. MUST ALLOW FOR USE OF" LOW FORCE" TO BE APPLIED WHEN BEING OPENED PER ANSI 404.2.9 C. CHANGES IN LEVEL WITHIN THE DWELLING UNITS BETWEEN 1/4" AND 1/2" ARE TO BE BEVELED WITH SLOPE NOT GREATER THAN 1:2. CHANGES IN LEVEL GREATER THAN 1/2" ARE TO BE RAMPED. THRESHOLDS AT ALL EXTERIOR DOORS, INCLUDING SLIDING DOOR TRACKS, MAY NOT BE MORE THAN 1/2" WITH CHANGES BEVELED WITH A SLOPE LESS THAN 1:2. SEE DETAILS PER ANSI 404.2.5, RAMPS ARE TO BE 1:12 MAX SLOPE (8.33%) BUT PREFERRED AT 1:20 (5%) a. LANDING SURFACE AT THE PRIMARY ENTRY DOOR TO THE UNIT ARE TO BE NO MORE THAN 1/2" BELOW FINISHED FLOOR. THE FINISHED FLOOR SURFACE OF THIS AREA THAT IS LOCATED IMMEDIATELY OUTSIDE THE ENTRY DOOR MAY BE SLOPED UP TO 1/8" PER FOOT FOR DRAINAGE. SEE NOTES ON BUILDING PLAN SHEETS. b. EXTERIOR BREEZEWAY, PATIO, OR BALCONY SURFACES ARE NOT TO BE MORE THAN 1/2" BELOW FINISHED FLOOR UNLESS THEY ARE CONSTRUCTED OF IMPERVIOUS MATERIALS SUCH AS CONCRETE. IN SUCH CASES THE SURFACE CANNOT BE MORE THAN 4" BELOW FINISHED FLOOR. UNITS: 1. BATHROOM NOTES: A. WALL DIMENSIONS AND FIXTURE LOCATIONS MUST BE HELD SO THAT THE MINIMUM CLEARANCES ARE PROVIDED AS SHOWN IN THE DETAILS. A CLEAR FLOOR SPACE (C.F.S) MINIMUM OF 30" X 48" MUST BE PROVIDED WITHIN THE BATHROOM EXCLUSIVE OF THE DOOR SWING. B. PROVIDE 2X MEMBER SIZE REQUIRED WOOD BLOCKING IN LINE OF STUD PLANE FOR WALLS NOTED AS REQUIRING REINFORCING FOR FUTURE GRAB BARS. SEE DETAILS. C. NOT USED D. LAVATORIES ARE TO BE INSTALLED WITH THE CENTERLINE OF THE FIXTURE A MINIMUM OF 2'-0" HORIZONTALLY FROM AN ADJOINING FINISHED WALL OR FIXTURE. SEE DETAILS. E. ACCESSIBLE URINALS IN COMMON USE BUILDINGS -BOTTOM TO BE AT 15" A.F.F. F. WATER CLOSETS ARE TO BE INSTALLED WITH THE CENTERLINE OF THE FIXTURE AT 18" HORIZONTALLY FROM THE FINISHED FACE OF THE ADJACENT WALL 2. CLOSET NOTES: A. WALK -IN CLOSETS: AT LEAST ONE (1) CLOTHES ROD MOUNTED NOT HIGHER THAN 54" A.F.F OR LESS THAN 9" A.F.F OR PROVIDE AN ADDITIONAL CLOSET ROD AS REQUIRED. SEE DETAILS. B. CLOSETS LESS THAN 25" IN DEPTH: PROVIDE SPACE AND/OR BRACKETS FOR RELOCATION OR RODS HIGHER THAN 54" A.F.F., TYP. SEE DETAILS. 3. KITCHEN NOTES: A. BASE CABINETS AND APPLIANCES FACING EACH OTHER SHALL HAVE A 40" MINIMUM CLEAR DIMENSION BETWEEN THEM. DIMENSION IS TAKEN FROM COUNTERTOP FACE TO OPPOSING WALL, APPLIANCE, OR COUNTERTOP FACE B. CLEAR FLOOR SPACE OF 30"X48" IS REQUIRED WITHIN KITCHENS TO ALLOW FOR PARALLEL OR PERPENDICULAR CENTERED APPROACH TO THE APPLIANCES AND FIXTURES, TYP. SEE UNIT PLANS. C. ENSURE THAT REFRIGERATOR, DISHWASHER, AND OVEN DOORS OPEN WITHOUT INTERFERING WITH EACH OTHER OR OTHER CABINETRY OR HARDWARE. 4. ELECTRICAL/ ENVIRONMENTAL CONTROLS: A. LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS AND OTHER ENVIRONMENTAL CONTROL ITEMS MUST BE POSITIONED SO THAT CONTROLS AND OUTLETS REMAIN REACHABLE EITHER WITH A PARALLEL OR PERPENDICULAR APPROACH WITH OR WITHOUT THE INTERFERENCE OF AN OBSTRUCTION. IN AN UNOBSTRUCTED CONDITION SWITCHES AND OUTLETS MUST BE MOUNTED IN A RANGE FROM 15" TO 48" ABOVE THE FLOOR. IN OBSTRUCTED CONDITIONS, OUTLETS AND SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" WHEN OBSTRUCTIONS PROTRUDE 20" OR LESS FROM THE DEVICE OR OUTLET BEING REACHED. IN AN OBSTRUCTED CONDITION WHERE A PARALLEL APPROACH IS NECESSARY FOR USE, OUTLETS AND SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 46". IN AN OBSTRUCTED CONDITION WHERE THE OBSTRUCTION PROTRUDES MORE THAN 20" FROM THE SWITCH OR DEVICE ARE TO BE MOUNTED AT A MAXIMUM HEIGHT OF 44". ALL HEIGHTS NOTED ARE TO BE TO THE HIGHEST PART OF THE DEVICE. B. PROVIDE ALL KITCHEN RECEPTACLES LOCATED ABOVE COUNTER SURFACES AT 44 INCHES MAXIMUM HEIGHT MEASURED TO THE CENTERLINE OF THE HIGHEST OUTLET AND INCLUDE THE FOLLOWING MOUNTING: a. 36" MIN. FROM ANY INSIDE CORNER IN "L" SHAPED KITCHEN b. 12" MIN. FROM ANY VERTICAL OBSTRUCTION (DEAD END WALL/REFRIGERATOR) c. WHERE MOUNTED OVER A COUNTER LESS THAN 12" IN WIDTH, PROVIDE THE OUTLET ON THE DEAD END WALL ADJACENT TO THE COUNTER AT NO MORE THAN 10" FROM THE FRONT EDGE OF THE COUNTER SURFACE. 5. MISC.: A. WATER FOUNTAINS TO BE MOUNTED AT 36" TO TOP OF SPOUT. B. UNOBSTRUCTED PUBLIC PAYPHONES TO BE MOUNTED AT 48" TO TOP OF PHONE OR OPERATIONAL CONTROL IT IS THE INTENT OF THE CONTRACT DOCUMENTS TO COMPLY WITH ALL APPROPRIATE FAIR HOUSING ACCESSIBILITY GUIDELINES AND GENERAL NOTES FOR PUBLIC AND COMMON USE FACILITIES. REPORT ANY CONFLICTS OR DISCREPANCIES TO THE ARCHITECT. FAIR HOUSING NOTES C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:54:53 AMC:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.60 2247601 FAIR HOUSING ACCESSIBILITY GUIDELINES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/2" = 1'-0"1 MIN. CLEAR FLOOR SPACE AT TOILETS 1/2" = 1'-0"2 MIN. CLEAR FLOOR SPACE AT BATHTUBS & SHOWERS 1/2" = 1'-0"3 MIN. BLOCKING AT TOILETS W/ FOLD-UP GRAB BARS 1/2" = 1'-0"4 BLOCKING AT TOILETS W/ ADJACENT WALLS 1/2" = 1'-0"5 BLOCKING AT BATHTUBS 1/2" = 1'-0"6 TYP. SHELVING MOUNTING HEIGHTS 1/2" = 1'-0"7 TYP. OUTLETS / SWITCHES / CONTROLS MOUNTING HEIGHTS 1/2" = 1'-0"8 MIN. ACCESSIBLE ROUTE CLEARANCES 3/4" = 1'-0"9 TYP. VIEW WINDOW MOUNTING HEIGHTS 1/2" = 1'-0"10 BLOCKING AT SHOWER STALL DATE DESCRIPTION REV GENERAL NOTES PROJECT SHALL COMPLY WITH ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES (SECTION 1009, CHAPTER 11 & APPENDIX E OF NCBC AND ICC A117.1-2009). I. SITE: 1. ACCESSIBLE SITE & EXTERIOR FACILITIES A. ACCESSIBLE ROUTES TO BE PROVIDED THROUGHOUT THE SITE TO ALL BUILDINGS B. ACCESSIBLE PARKING SPACES, LOADING ZONES AND CURB RAMPS TO BE PROVIDED, REFER TO CIVIL LANDSCAPE PLANS FOR ALL ACCESSIBLE ROUTES TO ALL BUILDINGS AND AMENITIES. II. COMMON USE FACILITIES 1. ACCESSIBLE STRUCTURES: A.BUILDINGS, MAIL KIOSKS, EXERCISE/LAUNDRY FACILITIES, COMPACTORS, ETC., PUBLIC AND COMMON USE SPACES MUST BE READILY ACCESSIBLE TO AND USABLE BY PEOPLE WITH DISABILITIES.PER FEDERAL, STATE, AND LOCAL MUNICIPAL REGULATIONS AND ANSI A117.1-2009 STANDARDS. 2. EXTERIOR DOORS: A.PROVIDE ½”MAX. LOW PROFILE THRESHOLD. THRESHOLDS ABOVE ¼”MUST BE BEVELED AT A SLOPE NO GREATER T HAN 1:2. B LEVER TYPE HARDWARE WITH DEAD-BOLT LOCKS TO BE PROVIDED. MAX. HEIGHT OF 48”A.F.F C.DOOR CLOSURE: MUST ALLOW FOR “LOW FORCE”TO BE APPLIED IN ORDER TO OPEN. D.SECURITY VIEWERS (PEEP HOLES) IF PROVIDED IN DOOR, TO BE INSTALLED AT A MAX. OF 44”A.F.F. E.PROVIDE A MINIMUM OF 32”CLEAR WIDTH OPENING (3’-0”DOOR) 3. INTERIOR DOORS: A.ALL DOORS TO PROVIDE A MINIMUM OF 32”CLEAR WIDTH WHEN OPENED. (3’-0”DOOR) AND PROVIDE 1’-6”CLEAR SPACE ON THE “PULL SIDE“AT THE HANDLE. B.LEVER TYPE HARDWARE TO BE PROVIDED. MAX. HEIGHT OF 48”AF.F. & MIN. HEIGHT OF 32”A.F.F. 4. KITCHENS/BREAK ROOMS A.PROVIDE ACCESSIBLE KNEE SPACE UNDER SINK AS REQUIRED. B.PROVIDE A 2’-6”MIN. (30”) WIDE WORK SPACE COUNTERTOP. C.MAXIMUM HEIGHT OF 34”AT TOP OF SINK AND TOP OF WORK SPACE SURFACE. D.SINK & PLUMBING TRIM TO BE H.C. ACCESSIBLE, OR HAVE A BOTTOM MOUNTED FREEZER. E.REFRIGERATOR NEEDS TO BE “SIDE BY SIDE”ACCESSIBLE, OR HAVE A BOTTOM MOUNTED FREEZER. F.ALL APPLIANCE CONTROLS NEED TO BE FRONT MOUNTED AND LESS THAN 4’-0”(48) A.F.F TYP. G.PROVIDE A 2’-6”(30”) X 4’-0”(48”) CLEAR FLOOR SPACE (C.F.S) APPROACH TO ALL APPLIANCES. C.F.S. MAY OVERLAP EACH OTHER. H.CLEAR FLOOR SPACE OF 30”X 48”IS REQUIRED WITHIN KITCHENS TO ALLOW FOR PARALLEL OR PERPENDICULAR APPROACH TO THE APPLIANCES AND FIXTURES, TYP. SEE UNIT PLANS FOR ADDITIONAL INFORMATION. 5. RESTROOMS: A.PROVIDE ACCESSIBLE KNEE SPACE UNDER SINK AS REQUIRED. B.ACCESSIBLE LAVATORY HEIGHT TO BE 34”MAX. A.F.F. C.INSTALL GRAB BARS AT H.C. ACCESSIBLE TOILET STALLS AS REQUIRED. D.TOILET ACCESSORIES TO MEET ALL H.C ACCESSIBLE REACH RANGES, AND BE APPROVED H.C. FIXTURES. E.ALL PLUMBING FIXTURES & TRIM UTILIZED IN H.C. ACCESSIBLE STALLS AND LAVATORIES SHOULD BE H.C. APPROVED FIXTURE TYPES. F.PROVIDE A 60”DIAMETER CLEAR FLOOR SPACE TURNING RADIUS WITHIN ROOM EXCLUSIVE OF DOOR SWING. G.ROLL-IN SHOWER TYPES TO PROVIDE CLEAR FLOOR SPACE, GRAB BARS AND ACCESSIBLE SEAT. SEE DETAILS H.WALL DIMENSIONS AND FIXTURE LOCATIONS MUST BE HELD SO THAT THE MINIMUM CLEARANCES ARE PROVIDED AS SHOWN. I.PROVIDE 2X MEMBER SIZE REQUIRED WOOD BLOCKING IN LINE OF STUD PLANE FOR WALLS NOTED AS REQUIRING REINFORCING FOR ALL GRAB BARS. SEE DETAILS J.LAVATORIES ARE TO BE INSTALLED WITH THE CENTERLINE OF THE FIXTURE A MINIMUM OF 2’-0" HORIZONTALLY FROM FINISHED SURFACE OF AN ADJOINING WALL OR FIXTURE. K.ACCESSIBLE URINALS IN COMMON USE BUILDINGS, LIP TO BE SET AT 17”MAX. A.F.F 6. FLOOR FINISHES: A.PROVIDE ”NON-SLIP”ABRASIVE SURFACE THROUGHOUT BUILDINGS ALONG ALL ACCESSIBLE ROUTES. B.FLOOR TRANSITIONS BETWEEN DIFFERENTMATERIALS NEED TO BE FLUSH, OR MEET THE ½”MAX. THRESHOLD REQUIREMENTS. 7. ELECTRICAL/ENVIRONMENTAL CONTROLS: A.LIGHT SWITCHES, ELECTRICAL OUTLETS, THERMOSTATS, AND OTHER ENVIRONMENTAL CONTROL ITEMS MUST BE POSITIONED SO THAT CONTROLS AND OUTLETS REMAIN REACHABLE EITHER WITH A PARALLEL OR PERPENDICULAR APPROACH WITH OR WITHOUT THE INTERFERENCE OF AN OBSTRUCTION. IN AN UNOBSTRUCTED CONDITION SWITCHES AND OUTLETS MUST BE MOUNTED IN A RANGE FROM 15”TO 48”ABOVE THE FLOOR. IN OBSTRUCTED CONDITIONS, OUTLETS AND SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48” WHEN OBSTRUCTIONS PROTRUDE 20”OR LESS FROM THE DEVICE OR OUTLET BEING REACHED. IN AN OBSTRUCTED CONDITION WHERE A PARALLEL APPROACH IS NECESSARY FOR USE, OUTLETS AND SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 46”. IN AN OBSTRUCTED CONDITION WHERE THE OBSTRUCTION PROTRUDES MORE THAN 20”FROM THE SWITCH OR DEVICE, AND WHEN A PERPENDICULAR APPROACH IS NECESSARY FOR USE, OUTLETS AND SWITCHES ARE TO BE MOUNTED AT A MAXIMUM HEIGHT OF 44”. 8. MISCELLANEOUS/OTHER: A.CORRIDORS TO HAVE A MINIMUM CLEAR WIDTH OF 4’-0”(48”) AND A MIN. HEAD HEIGHTS OF 6’-8”(80”). B.ELECTRIC WATER COOLERS & DRINKING FOUNTAINS TO BE MOUNTED AT 36”TO TOP OF SPOUT. C.UNOBSTRUCTED PUBLIC PAY-PHONES TO BE MOUNTED AT 48”TO TOP OF PHONE, AND WITH H.C. REACH RANGES. IT IS THE INTENT OF THE CONTRACT DOCUMENTS TO COMPLY WITH ALL APPROPRIATE FAIR HOUSING ACCESSIBILITY GUIDELINES AND GENERAL NOTES FOR LIVING UNITS AND GENERAL NOTES ON SHEET CD-60 ACCESSIBILITY GUIDELINES AND GENERAL NOTES FOR PUBLIC AND COMMON USE FACILITIES ON SHEETS CD-60 & CD-61 REPORT ANY CONFLICTS OR DISCREPANCIES TO THE ARCHITECT • PER THE NORTH CAROLINA ACCESSIBILITY CODE, PUBLIC AREAS (INCLUDING THE LEASING AREA AND MAIL ROOM) SHALL COMPLY WITH THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. • PER THE NORTH CAROLINA ACCESSIBILITY CODE, TENANT USE FACILITIES (INCLUDING THE CLUBROOM, CYBER CAFE, FITNESS ROOM, YOGA ROOM, OUTDOOR AMENITIES, POOL AND POOL COURTYARD) SHALL COMPLY WITH ANSI A 117.1, 2009 EDITION & NCBC 2018. • PER 1107.6.2.2 OF NCBC, A TYPE ACCESSIBLE DWELLING UNITS SHALL BE (100 X .05) + (334 X .02) = 11.68 ~ 12 TYPE A UNITS REQUIRED WITH 422 TYPE B UNITS REQUIRED. • 5%OF UNITS SHALL PROVIDE COMMUNICATION FEATURES COMPLYING WITH SECTION 809.5 OF THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. (SUCH FEATURES INCLUDE VISIBLE ALARMS FOR FIRE ALARM / SMOKE DETECTION, NOTIFICATION AND IDENTIFICATION.) THE FOLLOWING CHAPTER REQUIREMENTS ARE TO BE COMPLIED WITH FOR ALL NEW PROJECTS: CHAPTER (2) –GENERAL, (3) MISCELLANEOUS, (4) ACCESSIBLE ELEMENTS AND SPACES AND (7) BUSINESS AND MERCANTILE. GENERAL NOTES REPRINTED FROM THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN FOR THE PUBLIC AREAS OF THE PROJECT AND ANSI 117.1, 2009 EDITION FOR THE TENANT USE AREAS OF THE PROJECT. IT IS THE INTENT OF THE CONTRACT DOCUMENTS TO COMPLY WITH ALL APPROPRIATE FAIR HOUSING ACCESSIBILITY GUIDELINES AND GENERAL NOTES FOR LIVING UNITS ON SHEET CD-61. ANSI 117.1, 2009 EDITION IS BEING REFERENCED FOR TENANT USE FACILITIES ON CD-62. ADA ACCESSIBILITY GUIDELINES AND GENERAL NOTES FOR PUBLIC USE FACILITIES ARE LOCATED ON SHEETS CD-60 . REPORT ANY CONFLICTS OR DISCREPANCIES TO THE ARCHITECT NOTES: 1. DETAILS LISTED ON CD-61 ARE COMMON TO BOTH ANSI 117.1 AND 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. 2. DETAILS LISTED ON CD-62 ARE SPECIFIC TO ANSI 117.1, 2009 EDITION 3. DETAILS LISTED ON CD-61 ARE SPECIFIC TO 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. 4. 2010 ADA IN DETAILS BELOW REFERS TO 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. ANSI 117.1.1 IN THE DETAILS BELOW REFERS TO THE 2009 EDITION. 5. ACCESSIBILITY SHALL COMPLY WITH SECTION 1009, CHAPTER 11 & APPENDIX E OF NCBC AND ICC A117.1-2009. THE PROJECT SHALL COMPLY WITH CHAPTER 11: ACCESSIBLITY OF THE 2018 NORTH CAROLINA STATE BUILDING CODE ACCESSIBILITY NOTES: -PER SECTION 1103 OF THE 2018 NORTH CAROLINA STATE BUILDING CODE, "SITES, BUILDINGS, STRUCTURES, FACILITIES, ELEMENTS AND SPACES, TEMPORARY OR PERMANENT, SHALL BE ACCESSIBLE TO INDIVIDUALS WITH DISABILITIES." COMMON USE FACILITIES (INCLUDING MAIL ROOMS, EXERCISE ROOMS, CLUB ROOMS, LEASING AREAS, ETC, SHALL COMPLY WITH: ICC/ANSI A117.1 -09 -PER SECTION 1107.2, DWELLING UNITS AND SLEEPING UNITS THAT ARE REQUIRED TO BE ACCESSIBLE UNITS, TYPE "A" UNITS AND TYPE "B" UNITS SHALL COMPLY WITH THE APPLICABLE PORTIONS OF CHAPTER 10 OF ICC/ANSI A117.1 -09 -PER THE SECTION 1107.6.2.2.1, AT LEAST 5%, BUT NOT LESS THAN 1 UNIT SHALL BE TYPE "A"UNIT. ALL GROUP R-2 UNITS ON SITE SHALL BE CONSIDERED TO DETERMINE THE TOTAL NUMBER OF UNITS AND THE REQUIRED NUMBER OF TYPE "A" UNITS. TYPE "A" UNITS SHALL BE DISPERSED AMONG THE VARIOUS CLASSES OF UNITS. 1107.6.2.2.1 ACCESSIBLE DWELLING UNITS AND SLEEPING UNITS (SEE SITE PLANS AND BUILDING PLANS FOR UNITS LOCATIONS) (SEE BUILDING PLANS FOR UNITS DESIGNATED WITH H/C SYMBOL) -(100 X .05) + (257 X .02) = 10.14 ~ 12 TYPE A UNITS REQUIRED. -PER SECTION 1107.6.2.2.2, "WHERE THERE ARE FOUR OR MORE DWELLING UNITS OR SLEEPING UNITS INTENDED TO BE OCCUPIED AS A RESIDENCE IN A SINGLE STRUCTURE, EVERY DWELLNG UNIT AND SLEEPING UNIT INTENDED TO BE OCCUPIED AS A RESIDENCE SHALL BE A TYPE "B" UNIT" -ALL UNITS SHALL BE PROVIDED WITH COMMUNICATION FEATURES AND VISIBLE ALARMS PER FOR FIRE ALARM / SMOKE DETECTION PER CHAPTER 9 OF THE NCBC AND IN ACCORDANCE WITH ICC/ANSI A117.1 -ALL "PUBLIC" AREAS OF THE PROJECT SHALL COMPLY WITH THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN. *DWELLING UNITS SHALL COMPLY WITH REQUIREMENTS FOR ICC/ ANSI A117.1-03 AS "SAFE HARBOR" FOR COMPLIANCE WITH FAIR HOUSING ACT'S DESIGN AND CONSTRUCTION REQUIREMENTS PER FHA DESIGN MANUAL 1998.PREFERRED30" MAX32" MAX38" MIN.33" - 36"MAX 1' - 6" NOTE: 36" LONG MINIMUM GRAB BAR INSTALL WITH ONE END SPACE A MAX. OF 6" FROM THE SIDE WALL. 6" MAX.36" MIN. 60" CLEARANCE MIN. AREA OF BLOCKING SHOWN HATCHED(TYP.) ADDITIONAL 2" RECOMMENDED REINF. AREA SHOWN SHADED FLOOR LINE INSTALLED 36" GRAB BAR(TYP.) NOTE: IN TYPE "B" UNITS, WHERE WALL SPACE DOES NOT PERMIT A GRAB BAR COMPLYING WITH SECTION 604.5.2, REINFORCEMENT FOR A REAR WALL GRAB BAR 24" MIN. IN LENGTH CENTERED ON THE WATER CLOSET SHALL BE PROVIDED (SECTION, EXCEPTION 3.)PREFERED30" MAX.32" MIN.38" MIN.12" MAX TOP OF GRIPPING SURFACE33" - 36"MIN. AREA OF BLOCKING SHOWN HATCHED(TYP) WHERE APPLICABLE PROPOSED 42" GRAB BAR, (TYP) ADDITIONAL 2" RECOMMENDED REINF. AREA SHOWN SHADED 15" MIN.7"-9" 36" MAX 54" MIN FROM WALL 42" MIN FLOOR LINE NOTE: GRAB BARS, INCLUDING THOSE THAT ARE CONTINUOUS, MUST BE MOUNTED TO EXTEND AT LEAST 54" INCHES FROM THE BACK WALL. VERTICAL GRAB BAR NOT REQUIRED @ UNIT BATHS PER 1003.11.1, EXCEPTION 3 39"-41"18"39"-41" NOTE: IN TYPE "B" UNITS, AT WATER CLOSETS WHERE A SIDE WALL IS NOT AVAILABLE FOR A 42-INCH GRAB BAR, REINFORCEMENT FOR A SWING-UP GRAB BAR SHALL BE PERMITTED (SECTION, EXCEPTION 5) VERTICAL GRAB BAR NOT REQUIRED PER 2010 ADA 0' - 3"VARIES (SEE NOTE) +/- 2" MOUNTING PLATE(TYP.) ESCUTCHEON TO CONCEAL SCREWS(TYP.) GRAB BAR ADD APPROX. 2" TO EA. SIDE OF CENTERLINE DIMENSION FOR MOUNTING PLATE NOTE: GRAB BAR SIZES AS FOLLOWS: 12", 24", 36", & 48". (SEE PLANS FOR ADDITIONAL INFORMATION)60" MIN.(A) PULL SIDE 18" MIN XX > 8"48" MIN.(B) PUSH SIDEXX > 8"48" MIN.(C) PUSH SIDE, DOOR PROVIDED WITH BOTH CLOSER AND LATCHXX > 8"12" MIN BACK WALL HEAD END WALL CONTROL END WALL 24" MIN.12" MAX.24" MIN.24" MAX.12" MIN.15" - 16" REMOVABLE IN-TUB SEAT 9B 9A 9C 4" MAX.NOTE: IN TYPE A UNITS, GRAB BARS ARE NOT REQUIRED WHERE REINFORCEMENT COMPLYING WITH SECTION 1003.11.9 IS INSTALLED FOR THE FUTURE INSTALLATION OF GRAB BARS.38" MINIMUMHEAD END WALL8" - 10"33" - 36"30" MINIMUMGRAB BAR BLOCKING 12" GRAB BAR MIN. C 12" MAX. 24" MIN.24" MAX.8" - 10"33" - 36"4' - 0" MINIMUM HANDHELD SHOWER UNIT W/ SLIDEBAR & 59" LONG MIN. HOSE. (HANDHELD ATTACHMENT TO BE LOCATED BETWEEN 38" -48" A.F.F.)0' - 6" MIN.6" MAX.6" MAX.38" MINIMUMGRAB BAR BLOCKING 24" GRAB BAR MIN. BACK WALL B 38" MIN.24" MIN.CONTROL END WALL 8" - 10"33" - 36"30" MAX.24" GRAB BAR MIN. A HANDHELD SHOWER UNIT W/ SLIDEBAR & 59" LONG MIN. HOSE (HANDHELD ATTACHMENT TO BE LOCATED BETWEEN 38" - 48" A.F.F.) CONTROL LOCATION REMOVABLE IN-TUB SEAT 18" GRAB BAR MIN. VERTICAL GRAB BARS NOT REQUIRED PER 2010 ADA GRAB BAR BLOCKING 4" MAX 3" - 6"LOCATION OF SHOWER CONTROLS MIN. AREA OF BLOCKING SHOWN HATCHED, TYP.32" MIN.CLEAR CLEARCLEAR FLOOR SPACE TO ALIGN WITH FINISH SIDE OF CONTROL WALL C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:54:56 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.61 2247601 2010 ADA GUIDELINES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCACCESSIBILITY NOTES ACCESSIBILITY STATEMENT 1/2" = 1'-0"1 BLOCKING AT TOILETS - REARWALL 1/2" = 1'-0"2 BLOCKING AT TOILETS - SIDEWALL 3" = 1'-0"3 GRAB BAR 1/2" = 1'-0"4 MANEUVERING CLEARANCES AT RECESSED DOORS & GATES 3/4" = 1'-0"5 GRAB BARS FOR STANDARD BATHTUBS - PLAN 3/4" = 1'-0"6 GRAB BARS FOR STANDARD BATHTUBS - ELEVATION 3/4" = 1'-0"7 TRANSFER TYPE SHOWER COMPARTMENT SIZE AND CLEARANCE DATE DESCRIPTION REV 60" MIN.60" MIN.COMPLY WITH ANSI A117.1 FIG. 304.3(a) 60" MIN.36" MIN.12" MIN.12" MIN.36" MIN.60" MIN.COMPLY WITH ANSI A117.1 FIG. 304.3(b) 4' - 0"27" MIN28" - 34" MAXZY X NOTE: X SHALL BE < 25" (IN.) Z SHALL BE > X. WHEN X IS LESS THAN 20" (IN), Y SHALL BE 48" (IN) MAX. WHEN X IS 20"-25" (IN), Y SHALL BE 44" (IN) MAX. 4' - 0"2' - 6"Z X COMPLY WITH ANSI A117.1 FIG. 308.3, 308.3.1, 308.3.2 48" MIN.30" MIN.48" MIN.30" MIN.30" MIN.48" MIN.CLEAR FLOOR SPACE ANSI A117.1 -FIG. 305.3 FORWARD APPROACH ANSI A117.1 -FIG. 305.5(a) PARALLEL APPROACH ANSI A117.1 -FIG. 305.5(b)0' - 9"27" MAX80" MAX.CANE DETECTION AREA COMPLY WITH ANSI A117.1 FIG. 307.4 LATCH SIDE APPROACH -SWINGING DOORS 48" MIN.YPULL SIDE NOTE: Y = 48" IF DOOR HAS A CLOSER. PUSH SIDE 42" MIN24" MIN 24" MIN.YCOMPLY WITH ANSI A117.1 FIG. 404.2.3.2 NOTE: Y = 54" IF DOOR HAS A CLOSER.60"HINGE SIDE APPROACH -SWINGING DOORS 42" MIN.YPULL SIDE PUSH SIDE NOTE: X=12" & Y=48" IF DOOR HAS BOTH A CLOSER AND LATCH. 36" X 22" MIN. COMPLY WITH ANSI A117.1 FIG. 404.2.3.260" MIN.PULL SIDE PUSH SIDE 48" MIN.NOTE: X=12" IF DOOR HAS BOTH A CLOSER AND LATCH.X FRONT APPROACH -SWINGING DOORS 24" PREFERRED 18" MIN COMPLY WITH ANSI A117.1 FIG. 404.2.3.2 0' - 4"2' - 3"32" MIN. 32" MIN 36" PREFERRED FLOOR LINE 4" MAX. PROJECTION FOR OBJECTS HIGHER THAN 27" (TYP.) THAN 27" (TYP.) PROTRUDING OBJECTS LESS THAN 27" ARE DETECTABLE (TYP.) IF THE ACCESSIBLE ROUTE IS REDUCED TO LESS THAN 36", THE WALL HUNG OBJECT CANNOT BE WIDER THAN 24" MAX. (TYP.) 48" MIN. CLEARMIN.1' - 3"48" MAX. TOP OF SWITCHESFLOOR LINE RECEPTACLE (TYP.) DIRECTION OF TRAVEL SWITCHES/THERMOSTAT (TYP) (30" C.F.S PERP. TO WALL)9" MIN0' - 6" MIN.0' - 8" MIN. 17"-19"27" MIN.36" MAX.3' - 2 9/32"EQUIPMENT PERMITTED IN SHADED AREA SPOUT HEIGHT AND KNEE CLEARANCE 30" MIN.48" MIN. 24" MAX 17"-19"36" MIN.COMPLY WITH ANSI A117.1 FIG. 306.3 & FIG. 602.5 11" MIN. NOTE: ANY DRINKING FOUNTAIN THAT PROTUDES MORE THAN 4" INTO THE ACCESSIBLE PATH SHALL HAVE A CANE BARRIER ON BOTH SIDES. MAX. 0' - 6" 11" MIN. MIN. 0' - 8" 17" MIN 27" MIN.OF LAVATORY34" MAX TO TOPTO REFLECTING SURFACE40" MAX48" MIN. CLEAR DASHED LINE DENOTES MAX. SIZE OF MOUNTING BRACKETS FOR REMOVABLE PROTECTION AND APPEARANCE PANEL. FLOOR LINE DIRECTION OF TRAVEL HOT WATER AND DRAIN PIPES EXPOSED UNDER SINK SHALL BE INSULATED OR OTHERWISE CONFIGURED SO AS TO PROTECT AGAINST CONTACT. THERE SHALL ALSO BE NO SHARP OR ABRASIVE SURFACES UNDER SINK. REFLECTING SURFACE(WHEN APPLICABLE) COMPLY WITH ANSI A117.1 SEC. 606.10' - 9" MIN.PROVIDE FULL HEIGHT, OUTWARD SWINGING BASE CABINET DOORS AND TOE KICK OR REMOVABLE FACE AND TOE KICK AT BASE CABINET TO PERMIT ACCESSIBLE FRONT APPROACH 34" MAXCLEAR 30" MIN 2' - 10"OPEN 14 CD-29 COMPLY WITH ANSI A117.1 SEC. 804.4 11" MIN.12" PREFERRED9" MIN27" MIN.6 1/2" MAX34" MAX8" MIN. SINKS WITH REAR DRAIN PREFERRED PIPE PROTECTION AND APPEARANCE PANEL ADJACENT CABINET, WALL, AND FLOOR MUST BE FINISHED TO MATCH OPEN BOTTOM FOR VENTILATION AND ACCESS TO RESET BUTTONS PROVIDE FULL -HEIGHT OUTWARD SWINGING BASE CABINET DOORS AND TOE KICK OR REMOVABLE FACE AND TOE KICK TO PERMIT ACCESSIBLE FRONT APPROACH COMPLY WITH ANSI A117.1 SEC. 804.1 THE FRONT PARTITION AND AT LEAST ONE SIDE PARITION SHALL PROVIDE A TOE CLEARANCE OF 9" MINIMUM ABOVE THE FLOOR AND EXTENDING 6" BEYOND THE COMPARTMENT SIDE FACE OF THE PARTITION, EXCLUSIVE OF PARTITION SUPPORT MEMBERS. ■TOE CLEARANCE AT THE FRONT PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 62 INCHES (1575 MM) DEEP WITH A WALL-HUNG WATER CLOSET OR 65 INCHES (1650 MM) DEEP WITH A FLOOR-MOUNTED WATER CLOSET ■TOE CLEARANCE AT THE SIDE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 66" IN WIDTH. (ANSI 2003: 604.8.5 / ADA 2010: 604.8.1.4) 2' - 10"CLEAR 30" MIN27" MINMAX. 1' - 11 125/128" 1- 1/2" MAX COMPLY WITH ANSI A117.1 SEC. 804.1 KNEE AND TOE CLEARANCES REQUIRED ONLY IN TYPE 'A' DWELLING UNITS AND COMMON/PUBLIC AREAS 17" - 19"33" - 36"0' - 6" MIN.12" MIN.24" MIN. 36" MIN REAR WALL ELEVATION COMPLY WITH ANSI A117.1 SEC. 604.5.2 9" MIN. - 12" MAX.3' - 0"CLEAR MIN. 2' - 6"MAX17" MAX44" MAX2' - 6"4' - 0"18" MIN. - 2'-0" MAX DEEPTYP. URINAL URINAL PARTITION ACCESSIBLE ELONGATED RIM URINAL 30"X48" CLEAR FLOOR SPACE IN FRONT OF URINAL. NOTE: PROVIDE BLOCKING AND/OR ANCHORS IN WALLS FOR URINALS AND PARTITIONS PER MANUF. PRINTED INSTRUCTIONS COMPLY WITH ANSI A117.1 SEC. 605.1 PER 1210.3.2 OF NCBC, URINAL SCREENS SHALL BE 9" MIN. -12" MAX. ABOVE FLOOR AND BE 18" MIN. DEEP AND EXTEND 60" MIN. ABOVE FLOOR 17"-19"33" - 36"12" MIN.42" MIN. SIDE WALL ELEVATOIN 18" MIN.COMPLY WITH ANSI A117.1 FIGS. 604.4, 604.5.1, 604.7 INSTALL DISPENSORS PER ANSI A117.1 FIG. 604.7 TOILET PAPER DISPENSER ACCESS RANGE, DISPENSER LOCATED 1 1/2" BELOW GRAB BAR 18" MIN.2' - 9" MAX.0' - 1 1/2"42" MAX. 7" - 9" 24" MIN. 54" MIN.1' - 6"60" MIN.36" MIN12" MAX 54" MIN 59" MIN W/ FLOOR MOUNTED W.C 56" MIN. W/ WALL MOUNTED W.C.32" MIN4" MAX 32" MIN ALTERNATE DOOR LOCATION FLUSH HANDLE SHALL BE LOCATED ON WIDE SIDE OF ENCLOSURE 42" MIN LATCH APPROACH ONLY. OTHER APPROACHED 48" MIN. NOTE: IF PROVIDED, COAT HOOKS WITHIN TOILET COMPARTMENTS SHALL BE 48" AFF. COMPLY WITH ANSI A117.1 SEC. 604.9.3.10' - 4" MAX.60" MIN. 36" MIN.59" MIN. W/ FLOOR MOUNTED W.C.56" MIN W/ WALL MOUNTED W.C.36" MINFLUSH HANDLE SHALL BE LOCATED ON WIDE SIDE OF ENCLOSURE NOTE: IF PROVIDED, COAT HOOKS WITHIN TOILET COMPARTMENTS SHALL BE 48" AFF 12" MAX.54" MIN.42" MIN.1' - 6" MIN. 12" MIN. 24" 30X40 CLEAR FLOOR SPACE CENTERED TOP LOADING APPLIANCE. EITHER PROVIDE DOOR SWING AT 180 DEGREES LAUNDRY EQUIPMENT PLAN FRONT LAUNDRY EQUIPMENT ELEVATION TOP LAUNDRY EQUIPMENT ELEVATION 15" MIN - 34" MAX TO BOTTOM OF OPENING36" , MAX TO DOORCOMPLY WITH ANSI A117.1 FIG. 611.2 & 611.4 30X40 CLEAR FLOOR SPACE CAN OFFSET A MAXIMUM OF 24" FROM CENTER OF DOOR OPENING C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:01 AMC:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.62 2247601 2009 ANSI A117.1 GUIDELINES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/2" = 1'-0"1 CLEAR FLOOR SPACE REQUIREMENTS 1/2" = 1'-0"2 CLEAR FLOOR SPACE REQUIREMENTS B1 1/2" = 1'-0"3 CLEAR FLOOR SPACE REQUIREMENTS C1 1/2" = 1'-0"4 CLEAR FLOOR SPACE REQUIREMENTS D1 1/4" = 1'-0"5 STAIR PROTECTION 1/2" = 1'-0"6 ACCESSIBLE DOORS - A1 1/2" = 1'-0"7 ACCESSIBLE DOORS - B1 1/2" = 1'-0"8 ACCESSIBLE DOORS - C1 1/2" = 1'-0"9 TYP. MOUNTING HEIGHTS 1/2" = 1'-0"10 DRINKING FOUNTAIN & WATER COOLERS 1/2" = 1'-0"11 ACCESSIBLE LAVATORY 1/4" = 1'-0"12 KITCHEN SINK ELEVATION 1/2" = 1'-0"13 KITCHEN / BATHROOM SINK SECTION 1/4" = 1'-0"14 COUNTERTOP & WORK SPACE 1/2" = 1'-0"17 ACCESSIBLE STALL - STANDARD STALL B1 1/4" = 1'-0"16 MOUNTING HEIGHTS & CLEARANCES FOR URINALS 1/2" = 1'-0"15 ACCESSIBLE STALLS - STANDARD STALL B1 1/2" = 1'-0"18 ACCESSIBLE STALL - STANDARD STALL C1 1/2" = 1'-0"19 ACCESSIBLE STALLS - STANDARD STALL D1 1/2" = 1'-0"20 LAUNDRY EQUIPMENT DATE DESCRIPTION REV ROOM CORRIDOR NOTE: PARTITION TAGS SHOWN ARE EXAMPLES ONLY AND DO NOT REPRESENT ACTUAL TAGS USED ON PLANS ALL OTHER WALLS ARE WB3 088 WB3 077 EXTENDS THIS DISTANCE ROOM CORRIDOR WB3 077 WB3 099 WB3 088 1. FOR WALL FINISH, SEE FINISH SCHEDULE. 2. FOR EXTENT OF FIRE RATED ASSEMBLIES, SEE FLOOR/UNIT PLANS. RATED PARTITIONS SHALL BE CONTINUOUS FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE. PARTITIONS SHALL BE TIGHT FITTING AROUND ALL STRUCTURAL SHAPES AND PENETRATIONS. ALL PERIMETERS SHALL BE CAULKED WITH ACOUSTIC SEALANT. PROVIDE FIRE STOPPING. SEE SPECIFICATIONS. 3. DIFFERING PARTITION TYPES ARE TO BE ALIGNED SO THAT THE FINISH SURFACES ARE FLUSH AND CONTINUE UNBROKEN IN ROOM, UNLESS OTHERWISE NOTED. 4. PROVIDE BACKING PLATES AS REQUIRED AT ALL STUDS SUPPORTING EQUIPMENT AND FIXTURES SHOWN ON THE PLAN AND INTERIOR ELEVATIONS, SUCH AS GRAB BARS, HANDRAILS, ACCESSORIES, CASEWORK, SHELVING, LIGHT FIXTURES, PLUMBING, ETC. REFER TO THE SPECIFICATIONS. 5. AT CERAMIC TILE WALLS, PROVIDE CONTINUOUS BEAD OF SEALANT AT ALL INTERIOR CORNERS 6. SEE STRUCTURAL DRAWINGS FOR LOCATIONS OF PLYWOOD SHEATHING FOR SHEAR WALLS 7. PROVIDE TILE BACKER BOARD (SIMILAR TO A DENSSHIELD TILE BACKER BOARD) WHEREVER TILE IS INSTALLED IN A WET AREA. 8. AT ALL OTHER WET AREAS SUCH AS ALL REMAINING BATHROOMS WALLS/CEILINGS/LAUNDRY ROOM WALLS WHERE WET UTILITIES ARE LOCATED. WALLS WHERE ICE MACHINE CONNECTIONS ARE LOCATED AND MECHANICAL ROOM WHERE WET UTILITIES ARE LOCATED. MOISTURE RESISTANT GYPSUM BOARD IS REQUIRED. 9. MOISTURE RESISTANT GYPSUM BOARD IS ALSO ACCEPTABLE TO BE USED AS KITCHEN THE BACK SPLASHES. 10. PARTITION TYPES ARE INDICATED IN SQUARE BOX SYMBOLS LINKED TO THE WALL THEY DESCRIBE. 11. THE PARTITION TYPE EXTENDS THE ENTIRE LENGTH OF THE WALL WHERE IT IS SHOWN, ACROSS DOORS, WINDOWS, AND MINOR PROJECTIONS OR RECESSES (E.G. AT WATER FOUNTAINS). THE PARTITION TYPE ENDS AT THE INTERSECTION WITH ANOTHER SPACE, DEFINED BY AN INSIDE OR OUTSIDE CORNER, INCLUDING INTERVENING CORRIDORS, UNLESS OTHERWISE SPECIFICALLY NOTED ON THE DRAWINGS. SEE EXAMPLES BELOW: PARTITION GENERAL NOTES NOTES: 1. CI = CONTINUOUS INSULATION 2. NR = NO REQUIRED 3. SHGC = SOLAR HEAT GAIN COEFFICIENT 4. PF = PROJECTION FACTOR LOCATION / ASSEMBLY ROOFS: INSULATION ENTIRELY ABOVE DECK ATTIC AND OTHER BUILDING INSULATION SCHEDULE R-25 R-38 R-VALUE U-VALUE PER 2018 NORTH CAROLINA STATE BUILDING CODE: ENERGY CONSERVATION CODE PROJECT FALLS INTO ZONE 3A ( TABLE R301.1 C402.1.3 & C402.4 ) SHGC CI WALLS, ABOVE GRADE: MASS: METAL FRAMED WOOD FRAMED AND OTHER R-13 + R-3.8 OR R-20 WALLS, BELOW GRADE: BELOW GRADE WALL R-7.5 FLOORS: MASS WOOD FRAMING R-12.5 R-30 CI SLAB ON GRADE FLOORS: UNHEATED SLABS: HEATED SLABS: R-10 for 24" OPAQUE DOORS: SWINGING ROLL-UP OR SLIDING U-0.50 FENESTRATION: U-0.32 U-0.45 U-0.77 FRAMING MATERIAL OTHER THAN METAL W/ OR W/OUT REINFORCEMENT OR CLADDING STOREFRONT ENTRANCE DOORS CI R-9.5 CICI R-13 + R-7.5CI CI U-0.039 U-0.041 U-0.104 U-0.064 U-0.064 C-0.119C-0.119 U-0.064 U-0.033 F-0.540 F-0.860 U-0.50 0.25 0.33 0.40 PF <0.25 0.25<PF<0.5 PF>0.5 ALL OTHER GROUP R ALL OTHER GROUP R R-25 R-38 CI R-7.6 R-13 + R-7.5CI R-13 + R-3.8 OR R-20 CI R-7.5 CI R-12 R-30 CI R-15 for 24" NR R-15 for 24" U-0.039 U-0.041 U-0.123 U-0.064 U-0.064 U-0.064 U-0.033 F-0.730 F-0.860 U-0.70 U-0.50 WW3 33 WALL TYPE LEGEND: 1ST LETTER INDICATES STRUCTURAL MATERIAL C POURED IN PLACE CONCRETE F METAL FURRING / WOOD FURRING M MASONRY P PRECAST CONCRETE S METAL STUD / CHANNEL W WOOD 2ND LETTER INDICATES INSULATION O NONE B BATT INSULATION C CELLULOSE D BATT + BOARD INSULATION R BOARD INSULATION S SOUND FIRE RATING 1 1 HOUR 2 2 HOUR 3 3 HOUR 4 4 HOUR NUMBER INDICATES VARIATIONS Structural Number Component Size & Composition Material Designation Non-Stud if if Applicable Stud if Applicable C,M,P 00-09 MATERIAL C,F,M,P,S,W 10-19 MATERIAL +< 2x4 WOOD STUD 20-39 MATERIAL +2x4 WOOD STUD 40-59 MATERIAL +2x6 WOOD STUD 60-69 > 2x6 WOOD STUD C,M,P,S,W 70-79 MATERIAL +2x4 WOOD STUD EACH SIDE 80-89 MATERIAL +2x6 WOOD STUD EACH SIDE 90-99 MATERIAL VARYING DOUBLE STUD CONDITIONS C,F,M,P,S,W 100-109 MATERIAL +< 3 5/8" METAL STUD 110-129 MATERIAL +3 5/8" =< 6" METAL STUD 130-149 MATERIAL +>= 6" METAL STUD 150-159 MATERIAL +3 5/8"=< 6" METAL STUD EACH SIDE 160-169 MATERIAL +>=6" METAL STUD EACH SIDE C,M,P,S,W 170-179 MATERIAL +VARYING DOUBLE STUD CONDITIONS M 180-189 OTHER MASONRY *FIRE AND SOUND TEST NUMBERS BASED ON THE FOLLOWING: -FIRE RESISTANCE DIRECTORY 2011 EDITION BY UL (UNDERWRITERS LAB INC.) -FIRE RESISTANCE SOUND CONTROL DESIGN MANUAL 18TH EDITION 2009 BY GYPSUM ASSOCIATIONS. C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:03 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.70 2247601 PARTITION & ASSEMBLY GENERAL NOTES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1HR RATED 8" CMU FILL AS REQUIRED BY STRUCTURAL AND/ OR FIRE RATING NOTE: WHERE C.I.P. / CMU WALL ASSEMBLY IS USED BELOW GRADE, A 60MIL SELF-ADHERING MEMBRANE SHALL BE PROVIDED AS WATER RESISTIVE BARRIER. 60MIL SELF-ADHERING MEMBRANE AS REQ WHEN BELOW GRADE STRUCTURAL THICKNESS PER 2 HOUR CONCRETE WALL -WALL TYPE CO2 (PER FIGURE 721.1 (2)(a) -NCBC CHAP. 7 ITEM NUMBER 4.1.1) -SILICEOUS AGGREGATE CONCRETE 2 HOUR RATING- MIN. FINISH THICKNESS OF 5.0" -CARBONDATE AGGREGATE CONCRETE: 2 HOUR RATING - MIN. FINISHED THICKNESS OF 4.6" CO2 002 10" 12" 5/8" TYPE 'X' GWB OVER 7/8" METAL FURRING AT EITHER SIDE OR BOTH SIDES PER FINISH SCHEDULE CO2 003 8" NOTE: 1) SEE ELEVATIONS FOR LOCATIONS WHERE EXTERIOR FINISH IS REQUIRED FOR WALL TYPE CO2 2) SEE FINISH SCHEDULE FOR INTERIOR FINISHES WITH WALL TYPE CO2 3) WHERE CMU WALL ASSEMBLY IS USED BELOW GRADE, A 60MIL SELF-ADHERING MEMBRANE SHALL BE PROVIDED AS WATER RESISTIVE BARRIER. R-7.5 (MIN) INSULATION BOARD AT OCCUPIED SPACES ON EXTERIOR FACE OF WALL CO2 001 STO FINISH STO MESH EMBEDDED IN BASE COAT FLUID-APPLIED STOGUARD AIR/MOISTURE BARRIER EXTERIOR COORDINATE W/ ELEVATIONS INTERIOR COORDINATE W/ FINISH SCHEDULE LIQUID APPLIED AIR AND MOISTURE BARRIER CAST-IN-PLACE CONCRETE WALL -REFER TO STRUCTURAL CO3 003 12" 3 HOUR CONCRETE WALL -WALL TYPE CO3 (PER FIGURE 721.1 (2)(a) -NCBC CHAP. 7 ITEM NUMBER 4.1.1) -SILICEOUS AGGREGATE CONCRETE 3 HOUR RATING- MIN. FINISH THICKNESS OF 6.2" -CARBONDATE AGGREGATE CONCRETE: 3 HOUR RATING - MIN. FINISHED THICKNESS OF 5.7" 5/8" TYPE 'X' GWB OVER 7/8" METAL FURRING PER FINISH SCHEDULE CO3 002 10" R-7.5 (MIN) INSULATION BOARD AT OCCUPIED SPACES ON EXTERIOR FACE OF WALL NOTE: WHERE C.I.P. / CMU WALL ASSEMBLY IS USED BELOW GRADE, A 60MIL SELF-ADHERING MEMBRANE SHALL BE PROVIDED AS WATER RESISTIVE BARRIER. STO FINISH STO MESH EMBEDDED IN BASE COAT FLUID-APPLIED STOGUARD AIR/MOISTURE BARRIER STRUCTURAL THICKNESS PER EXTERIOR COORDINATE W/ ELEVATIONS INTERIOR COORDINATE W/ FINISH SCHEDULE UL# U905 2 HR RATED 8" CMU FILL AS REQUIRED BY STRUCTURAL 7/8" FURRING CHANNEL (1) LAYER 5/8" GYPSUM BOARD WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) FIBER CEMENT PANEL R-7.5 CONTINUOUS RIGID INSULATION Z-CHANNEL EXTERIOR INTERIOR UL# U905 2 HR RATED 8" CMU FILL AS REQUIRED BY STRUCTURAL 7/8" FURRING CHANNEL (1) LAYER 5/8" GYPSUM BOARD UL# U905 2 HR RATED 8" CMU FILL AS REQUIRED BY STRUCTURAL (1) LAYER 5/8" GYPSUM BOARD EXTERIOR INTERIOR FIRE RETARDANT EXTERIOR SHEATHING WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) R-7.5 CONTINUOUS RIGID INSULATION METAL PANEL SNAP-ON STANDING SEAM CLIP W/ FASTENERS ATTACHED PER MANUFACTURER SNAP-ON STANDING SEAM CAP DRAINAGE MAT 7/8" FURRING CHANNEL FILL AS REQUIRED BY STRUCTURAL 8" 7/8" FURRING CHANNEL (1) LAYER 5/8" GYPSUM BOARD UL# U905 2 HR RATED 8" CMU FILL AS REQUIRED BY STRUCTURAL *STC RATING 55-59 SOUND TEST : EXTERIOR COORDINATE W/ ELEVATIONS LIQUID APPLIED AIR AND MOISTURE BARRIER 12" 5/8" TYPE 'X' GWB OVER 7/8" METAL FURRING PER FINISH SCHEDULE CO 002 10" R-7.5 (MIN) INSULATION BOARD AT OCCUPIED SPACES ON EXTERIOR FACE OF WALL NOTE: WHERE C.I.P. / CMU WALL ASSEMBLY IS USED BELOW GRADE, A 60MIL SELF-ADHERING MEMBRANE SHALL BE PROVIDED AS WATER RESISTIVE BARRIER. STO FINISH STO MESH EMBEDDED IN BASE COAT FLUID-APPLIED STOGUARD AIR/MOISTURE BARRIER INTERIOR COORDINATE W/ FINISH SCHEDULE CO 003 6" CAST-IN-PLACE CONCRETE WALL -REFER TO STRUCTURAL STRUCTURAL THICKNESS PER CO 001 8" 8" CMU FILL AS REQUIRED BY STRUCTURAL AND/ OR FIRE RATING NOTE: WHERE C.I.P. / CMU WALL ASSEMBLY IS USED BELOW GRADE, A 60MIL SELF-ADHERING MEMBRANE SHALL BE PROVIDED AS WATER RESISTIVE BARRIER. 60MIL SELF-ADHERING MEMBRANE AS REQ WHEN BELOW GRADE FIBER CEMENT LAP SIDING FILL AS REQUIRED BY STRUCTURAL FIBER CEMENT PANEL EXTERIOR INTERIOR FIRE RETARDANT EXTERIOR SHEATHING WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) FIBER CEMENT PANEL ON Z- CHANNELS FILL AS REQUIRED BY STRUCTURAL CEMBRIT PANEL EXTERIOR INTERIOR FIRE RETARDANT EXTERIOR SHEATHING WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) CEMBRIT PANEL FILL AS REQUIRED BY STRUCTURAL FIRE RETARDANT EXTERIOR SHEATHING WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) FIBER CEMENT LAP SIDING ON Z- CHANNELS EXTERIOR INTERIOR FILL AS REQUIRED BY STRUCTURAL METAL PANEL EXTERIOR INTERIOR FIRE RETARDANT EXTERIOR SHEATHING WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) METAL PANEL SNAP-ON STANDING SEAM CLIP W/ FASTENERS ATTACHED PER MANUFACTURER DRAINAGE MAT 8" BRICK VENEER EXTERIOR INTERIOR FIRE RETARDANT EXTERIOR SHEATHING BRICK VENEER WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) GALVANIZED STEEL 2 PIECE ADJUSTABLE WALL TIES SPACED AT 16" O.C.C VERTICALLY AND 32" O.C. HORIZONTALLY AIR SPACE 6" STRIP SELF ADHERED FLASHING AT WALL TIES FILL AS REQUIRED BY STRUCTURAL R-7.5 CONTINUOUS RIGID INSULATION R-7.5 CONTINUOUS RIGID INSULATION R-7.5 CONTINUOUS RIGID INSULATION FIBER CEMENT PANEL ON Z- CHANNELS SNAP-ON STANDING SEAM CAP R-7.5 CONTINUOUS RIGID INSULATION 8" 7/8" FURRING CHANNEL (1) LAYER 5/8" GYPSUM BOARD UL# U905 2 HR RATED 8" CMU FILL AS REQUIRED BY STRUCTURAL AND/ OR FIRE RATING *STC RATING 55-59 SOUND TEST : STO FINISH R-7.5 (MIN) INSULATION BOARD AT OCCUPIED SPACE ON EXTERIOR FACE OF WALL MO2 102 12" NOTE: WHERE C.I.P. / CMU WALL ASSEMBLY IS USED BELOW GRADE, A 60MIL WATERPROOF MEMBRANE SHALL BE PROVIDED AS WATER RESISTIVE BARRIER. MO3 001 8" UL# U907 -3HR CMU WALL STO MESH EMBEDDED IN BASE COAT FLUID-APPLIED STOGUARD AIR/MOISTURE BARRIER EXTERIOR COORDINATE W/ ELEVATIONS INTERIOR COORDINATE W/ FINISH SCHEDULE C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:06 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.71 2247601 MASS WALL PARTITION DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1HR RATED CMU WALL 1 2 HR RATED CAST IN PLACE WALL 2 3 HR CAST IN PLACE WALL 3 UL# U905 - 2 HR 8" CMU W/ FIBER CEMENT PANEL 4 UL# U905 - 2 HR 8" CMU W/ FURRING 5 UL# U905 - 2 HR 8" CMU W/ FIBER CEMENT PANEL 7 UL# U905 - 2 HR 8" CMU W/ FURRING 8 NON RATED CAST IN PLACE WALL 9 NON RATED CMU WALL 10 UL# U905 2 HR EXT. CMU WALL W/ MULTIPLE FINISH CONDITIONS 11 UL# U905 - 2HR CMU WALL 12 DATE DESCRIPTION REV FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF SEALANT 1 LAYER 5/8" TYPE "X" GYPSUM BOARD METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF SEALANT, CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS FO 1306" FB 130 WALL TO HAVE BATT INSULATION AT WALL TYPES FB 110 AND FB 130 FB 110 6" 3 5/8" FO 110 3 5/8" FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF SEALANT, EACH SIDE 1 LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF SEALANT, EACH SIDE CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS UNIT UNIT SO 130 6" 3 5/8" SB 130 WALL TO HAVE BATT INSULATION AT WALL TYPES SB 110 AND SB 130 SB 110 3 5/8" 6" FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF SEALANT, EACH SIDE (2) LAYER 5/8" TYPE "X" GYPSUM BOARD ONE SIDE TO ALIGN WITH (2) LAYERS GWB AT RATED WALL ASSEMBLY ADJACENT-REFER TO PLAN FOR SPECIFIC CONDITIONS AND MAINTAIN WALL FINISH ALIGNMENT METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF SEALANT, EACH SIDE CL CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS CL UNIT UNIT 3 5/8" 1 LAYER 5/8" TYPE "X" GYPSUM BOARD FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF FIRE SEALANT, EACH SIDE 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD EACH SIDE METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF FIRE SEALANT, EACH SIDE CL CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS CL INTERIOR INTERIOR SB2 170 MIN 3 1/2" BATT INSULATION IN BOTH WALLS 1" AIRSPACE *STC RATING 55-59 SOUND TEST : RAL TL76-156 0' - 1" HEAD CONDITION PLAN CONDITION SB2 1503 5/8" EA. SIDE 6" EA. SIDE 3 5/8" (1) SIDE 6" (1) SIDE BRACING, VERTICAL SPACING NOT TO EXCEED 48" O.C. FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF FIRE SEALANT, EACH SIDE 1 LAYER 5/8" TYPE "X" GYPSUM BOARD EACH SIDE METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF FIRE SEALANT, EACH SIDE CL CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS CL INTERIOR INTERIOR SB1 135 6" 3 5/8" BATT INSULATION; R-13 WITH 3 5/8" MTL STUD, R-19 WITH 6" MTL STUD; REF UL ASSEMBLY FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF FIRE SEALANT, EACH SIDE 1 LAYER 1-3/8" QUIETROCK 545 GYPSUM BOARD EACH SIDE METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF FIRE SEALANT, EACH SIDE CL CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS CL INTERIOR INTERIOR SB1 135 6" 3 5/8" BATT INSULATION FLOOR CONDITION SB1 140 -STC 53 PER SLR REPORT 6" FLOOR STRUCTURE CONT. BEAD OF FIRE SEALANT, EACH SIDE 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD EACH SIDE BASE AS SCHEDULE, SEE INTERIOR DWGS. CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF FIRE SEALANT, EACH SIDE CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS UNIT OR ELEC. / MECH. R-19 BATT INSULATION CORRIDOR 1 HR CORRIDOR -25 GAUGE 6" METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. 2 HR INT BRNG -6" METAL STUD FRAMING (SEE STRUCTURAL FOR GAUGE AND SPACING 6" SB1 140 UL# U425 1HR CORRIDOR NON BEARING METAL STUD WALL AT PODIUM LEVELS FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF FIRE SEALANT, EACH SIDE 2 LAYERS 5/8" TYPE 'X' GYPSUM BOARD FOR STC RATING SHOWN BELOW 6" METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. R-19 BATT INSULATION CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF FIRE SEALANT, EACH SIDE CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS UNIT UNIT 6" STC 59 PER SLR REPORT 1/2" RESILIENT CHANNELS SPACED VERTICALLY @ 24" O.C. FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF SEALANT 1 LAYER 5/8" TYPE "X" GYPSUM BOARD METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF SEALANT, CL CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS CL SB1 133 6" 3 5/8" CORRIDORPARKING DECK BATT INSULATION 1/2" STRUCTUAL FRT SHEATHING 1 HOUR BEARING STUD WALL: (CALCULATED PER IBC CH. 7, SECTION 722.6) -(1) LAYER 5/8" TYPE 'X' GYPSUM BOARD = 40 MIN. -(1) LAYER 1/2" STRUCTURAL FRT SHEATHING = 30 MIN. SB1 132 6" 3 5/8" FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF FIRE SEALANT, EACH SIDE 2 LAYERS 1/2" TYPE "X" GYPSUM BOARD EACH SIDE METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. SOUND ATTENUATION BATT (SEE WALL ASSEMBLY) CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF FIRE SEALANT, EACH SIDE CL CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS CL CORRIDOR UNIT 6" METAL STUD 1 LAYER 5/8" GYPSUM BOARD SHEATING 2 LAYERS 3/4" TYPE "X" GYPSUM BOARD STUCCO R-13 BATT INSULATION IN 6" METAL STUD STO FINISH COAT FLUID-APPLIED STOGUARD AIR/MOISTURE BARRIER STO MESH EMBEDDED IN BASE COAT R-7.5 ci (MIN) CONTINUOUS RIGID INSULATION NOTE: ENVELOPE BASIS OF DESIGN IS TO BE StoTherm ci XPS SD2 140 8" METAL STUD EXTERIOR COORDINATE W/ ELEVATIONS INTERIOR COORDINATE W/ FINISH SCHEDULE FLOOR CONDITION 6" STC: 60 TEST # NOAL 18-0910 SEPARATING AMENITY SPACES FROM RESIDENTIAL SPACES FLOOR STRUCTURE CONT. BEAD OF FIRE SEALANT, EACH SIDE 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD FOR STC RATING SHOWN BELOW 6" METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF FIRE SEALANT, EACH SIDE CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS AMENITY R-19 BATT INSULATION UNIT 1 LAYER 1-3/8" QUIETROCK 545 GYPSUM BOARD 5/8" CEMENT BOARD AT WET WALL FOR SPA AREA FINISH AS SCHEDULED C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:10 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.72 2247601 METAL STUD WALL PARTITION DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCNON-RATED INTERIOR NON-BEARING METAL STUD FURRING WALL 1 NON-RATED INTERIOR NON-BEARING METAL STUD WALL 2 NON-RATED INTERIOR NON-BEARING METAL STUD WALL W/ EXTRA GWB LAYER (1) SIDE 3 UL# U420 2 HR INTERIOR NON-BEARING METAL STUD WALL 4 UL# U425 1 HR INTERIOR BEARING METAL STUD WALL 5 UL# U425 1 HR INTERIOR BEARING METAL STUD WALL 6 UL# U425 2HR CORRIDOR / DEMISING BEARING METAL STUD WALL 7 UL# U425 - 1HR DEMISING BEARING METAL STUD WALL 8 UL# U425 - 1HR RATED BEARING METAL STUD WALL 9 UL# U425 - 1HR RATED CORRIDOR BEARING METAL STUD WALL 10 UL# W425 2 HR - EXTERIOR METAL STUD WALL WITH STUCCO FINISH CONDITIONS 11 UL# U425 2 HR INTERIOR BEARING METAL STUD WALL 12 DATE DESCRIPTION REV 1 LAYER 5/8" TYPE "X" GYPSUM BOARD 7/8" RESILIENT CHANNEL 7/8" RESILIENT CHANNEL EXTERIOR FIRE RETARDANT EXTERIOR SHEATHING WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) 3/8" THICK BY 1-1/2" WIDE FRT WOOD FURRING STRIP INSTALLED VERTICALLY (MUST COMPLY W/ NFPA 285) SPACING PER MANUFACTUERS SPECIFICATIONS FIBER CEMENT PANEL FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF FIRE SEALANT, EACH SIDE 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD @ EACH SIDE FOR UNIT TO UNIT STC RATING SHOWN BELOW 25 GAUGE 6" METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONTINUOUS METAL RUNNER CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK CONT. BEAD OF FIRE SEALANT, EACH SIDE CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS CL UNIT OR MAILROOM 6" R-19 BATT INSULATION STC 57 PER SLR REPORT UNIT OR FIRE COMMAND CENTER FLOOR STRUCTURE FLOOR CONDITION CONT. BEAD OF SEALANT AT EACH SIDE 1 LAYER 5/8" TYPE "X" GYPSUM BOARD AT EACH SIDE METAL STUD FRAMING SPACED AT 24" O.C. U.N.O. BASE AS SCHEDULE, SEE INTERIOR DWGS. CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK AT EACH SIDE CONT. BEAD OF SEALANT, CONT. BEAD OF ACOUSTICAL SEALANT, ALONG TOP OF TRACK ON SCHEDULED SOUND PARTITIONS AT EACH SIDE 0' - 0 5/8"0' - 2 1/2" 0' - 7" @SB 151 0' - 5"0' - 2 1/2"0' - 0 5/8" SB 151 12" 10" INTERIOR ADDITIONAL LAYER OF GYP AS NEEDED TO ALIGN WITH WALLS BEYOND. (2) 5/8" TYPE "X" GWB 1 LAYER 1" GYPSUM LINER PANEL SHAFT BATT INSULATION 2 1/2" C-H SHAPED 25 GAUGE METAL STUDS SPACED 24" (MAX) O.C. SYSTEM B FURRING WALL WHERE LOAD BEARING CONDITIONS OCCUR SB2 106 UL# U415 2 HR RATED SHAFT WALL -SYSTEM B SYSTEM A 5/8" TYPE "X" GWB 1 LAYER 1" GYPSUM LINER PANEL BATT INSULATION 6" METAL STUD INTERIOREXTERIOR FIRE RETARDANT EXTERIOR SHEATHING 1 LAYER 5/8" TYPE "X" GYPSUM BOARD WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) R-7.5 CONTINUOUS RIGID INSULATION FIRE RETARDANT EXTERIOR SHEATHING 6" METAL STUD INTERIOREXTERIOR FIRE RETARDANT EXTERIOR SHEATHING 1 LAYER 5/8" TYPE "X" GYPSUM BOARD WEATHER RESISTANT BARRIER (MUST COMPLY W/ NFPA 285) CEMBRIT PANEL R-7.5 CONTINUOUS RIGID INSULATION HP GFRC PANELS BACKER ROD AND SEALANT FIELD ATTACH "Z" CLIP AT STUD FRAMING 2 LAYERS 5/8" TYPE "X" GYPSUM BOARD 1 LAYER 1" GYPSUM LINER PANEL 2 1/2" C-H METAL STUDS @ 24" O.C. SHAFT INTERIOR BATT INSULATION C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:13 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.73 2247601 METAL STUD WALL PARTITION DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC7/8" FURRING WALL 1 EXTERIOR 7/8" FURRING WALL 2 UL #U419 - 1HR DEMISING NON-BEARING WALL 3 NON-RATED INTERIOR NON-BEARING METAL DOUBLE STUD WALL 4 UL# U415 1 HR RATED SHAFT WALL - SYSTEM A 5 UL# V454 1 HR - EXTERIOR METAL STUD WALL W/ SHEATHING FINISH 6 UL# V454 1 HR - EXTERIOR METAL STUD WALL W/ GFRC FINISH 7 UL# U428 2 HR RATED NON-BEARING SHAFT WALL 8 DATE DESCRIPTION REV 5/8" TYPE "X" GYPSUM BOARD @ EACH SIDE 2X4 WOOD STUD (SEE STRUCTURAL, DWGS.) NOTE: USE 1/2" CEMENT BACKER UNIT WITH CERAMIC TILE WHERE INDICATED ON FINISH SCHEDULE INTERIOR INTERIOR *BATT INSULATION PER WALL TAG 5/8" GYPSUM BOARD @ EACH SIDE 2x4 WOOD STUD (SEE STRUCTURAL DWGS.) NOTE: USE 1/2" CEMENT BACKER UNIT W/ CERAMIC TILE WHERE INDICATED ON FINISH SCHEDULE INTERIORINTERIOR *BATT INSULATION PER WALL TAG INTERIOR 5/8" GYPSUM BOARD 7/8" METAL HAT CHANNEL INTERIOR 5/8" TYPE "X" GYPSUM BOARD ** BATT INSULATION PER WALL TAG 2X4 WOOD STUD 1" AIR SPACE SEPERATION FROM ANY WALL OR FOUNDATION, U.N.O. 0' - 1" 5/8" GYPSUM BOARD 2X4 WOOD STUD INTERIOR 1" AIR SPACE SEPARATION FROM ANY WALL OR FOUNDATION, U.N.O. *BATT INSULATION PER WALL TAG 0' - 1" 5/8" TYPE 'X' GYPSUM BD. *3 1/2" BATT INSULATION IN BOTH WALLS 2X4 WD STUDS STAGGERED @ 16" O.C. -SEE STRUCTURAL DWGS. 1" AIRSPACE 5/8" TYPE 'X' GYP. BD. STRUCTURAL SHEATHING ONE SIDE OF AIR SPACE AS REQUIRED BY STRUCTURAL DRAWINGS. AMENITY UNIT NOTES: THE FIRE BLOCKING GYPSUM BD. SHOULD BE HELD 1/4" SHORT & ATTACHED TO ONE SIDE ONLY. SEAL ALL PENETRATIONS THROUGH DEMISING WALL PARTITIONS USE PUTTY PADS ON THE BACK OF ALL OUTLET BOXES, BOTH HIGH-VOLTAGE & LOW-VOLTAGE BOXES. 1-3/8" THICK QUIETROCK 545 GYPSUM PANEL 5/8" TYPE 'X' GYPSUM BD. *3 1/2" BATT INSULATION IN BOTH WALLS 2X4 WD STUDS STAGGERED @ 16" O.C. -SEE STRUCTURAL DWGS. 1" AIRSPACE 5/8" TYPE 'X' GYP. BD. STRUCTURAL SHEATHING ONE SIDE OF AIR SPACE AS REQUIRED BY STRUCTURAL DRAWINGS. **STC -56 INTERIOR INTERIOR NOTES: THE FIRE BLOCKING GYPSUM BD. SHOULD BE HELD 1/4" SHORT & ATTACHED TO ONE SIDE ONLY. SEAL ALL PENETRATIONS THROUGH DEMISING WALL PARTITIONS USE PUTTY PADS ON THE BACK OF ALL OUTLET BOXES, BOTH HIGH-VOLTAGE & LOW-VOLTAGE BOXES. 0' - 1" 5/8" TYPE "X" GYPSUM BOARD 2X6 WOOD STUD (SEE STRUCTURAL) BLDG 4" AIR SPACE SEPARATION FROM PARKING DECK WALL, U.N.O. *BATT INSULATION PER WALL TAG 0' - 4" PARKING DECK STRUCTURAL SHEATING AS REQUIRED BY STRUCTURAL DWGS. 2X4 WOOD STUD WALL 1 HOUR BEARING STUD WALL: (CALCULATED PER IBC CH. 7) -2X WOOD STUDS @ 16" O.C. -(1) LAYER 5/8" TYPE "X" GYPSUM BOARD AT FIRE WALL UNIT DEMISING WALL: MIN. 3 1/2" BATT INSULATION @ 2X4 STUD WALL. (MIN. 5 1/2" @ 2X6) AT FIRE WALL 3" REINFORCED AUTOCLAVED AERATED CONCRETE PANELS 0' - 1 1/2" GAP AAC PANEL 0' - 3" 0' - 1 1/2" GAP 0' - 6" 5/8" TYPE "X" GYPSUM BOARD EACH SIDE (TYP.) 2X4 WOOD STUD (SEE STRUCTURAL DWGS.) NOTE: USE 5/8" CEMENT BACKER UNIT W/ CERAMIC TILE WHERE INDICATED ON FINISH SCHEDULE 1/2" RESILIENT CHANNEL DELUXE UNIT CORRIDOR MIN. R-13 BATT INSULATION, PRESSURE FIT TO FILL STUD CAVITY **STC 56 SHEAR CONDITION PROVIDE STRUCTURAL SHEATHING IN LIEU OF RESILIENT CHANNEL AS REQUIRED BY STRUCTURAL DRAWINGS C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:17 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.74 2247601 WALL PARTITION DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U305 1-HOUR RATED INT. BEARING WALLWO1 021 WO1 041 WB1 021 WB1 041 SIMILAR TO WO1 021 EXCEPT FOR 2x6 WOOD STUDS SIMILAR TO WO1 021 EXCEPT WITH BATT INSULATION SIMILAR TO WO1 041 EXCEPT WITH BATT INSULATION NON-RATED & NON BEARING INTERIOR WALLWO 020 WO 040 WB 020 WB 040 SIMILAR TO WO 020 EXCEPT FOR 2x6 WOOD STUDS SIMILAR TO WO 020 EXCEPT WITH BATT INSULATION SIMILAR TO WO 020 EXCEPT WITH BATT INSULATION INTERIOR METAL HAT CHANNEL FURRING WALLFO 100 FO 104 SIMILAR TO FO 100 EXCEPT FOR 1 5/8" METAL STUDS 1-HOUR INTERIOR BEARING WOOD STUD FURRING WALLFB1 020 FB1 040 SIMILAR TO FB1 020 EXCEPT FOR 2x6 WOOD STUDS FO1 020 SIMILAR TO FB1 020 EXCEPT WITHOUT BATT INSULATION FO1 040 SIMILAR TO FB1 020 EXCEPT FOR 2X6 WOOD STUDS WITHOUT BATT INSULATION NON-RATED & NON-BEARING WOOD FURRING WALLFO 020 FO 040 FB 020 FB 040 SIMILAR TO FO 020 EXCEPT FOR 2x6 WOOD STUDS SIMILAR TO FO 020 EXCEPT WITH BATT INSULATION SIMILAR TO FO 040 EXCEPT WITH BATT INSULATION UL #341 1-HOUR RATED DEMISING WALL AT AMENITYWB1 072 WB1 082 WB1 092 SIMILAR TO WB1 072 EXCEPT FOR 2X6 WOOD STUDS ONE EACH SIDE SIMILAR TO WB1 072 EXCEPT FOR 2X6 WOOD STUDS ON ONE SIDE AND 2X4 WOOD STUDS ON THE OTHER SIDE UL #341 1-HOUR RATED DEMISING WALLWB1 070 WB1 080 WB1 090 SIMILAR TO WB1 070 EXCEPT FOR 2x6 WOOD STUDS ON EACH SIDE SIMILAR TO WB1 070 EXCEPT FOR 2x6 WOOD STUDS ON ONE SIDE & 2X4 WOOD STUDS ON THE OTHER SIDE IBC CHAPTER 7 CALCULATED 1-HOUR BEARING WOOD STUD FURRING WALL @ PARKING DECKFB1 040 UL #U210 3-HOUR RATED AUTOCLAVED AERATED CONCRETE (ACC) FIREWALL 1 UL #U344 1-HOUR INT. BEARING WALL AT UNIT/CORRIDOR 2 DATE DESCRIPTION REV 16" HAMBRO STEEL JOISTS, SEE STRUCTURAL 1 LAYER 5/8" TYPE 'C' GYP. BD. INTERIOR OF UNIT/ ELECTRICAL ROOM INTERIOR OF UNIT / IDF ROOM 7/8" FURRING CHANNELS @ 24" O.C. WIRE TIED TO JOISTS 3" THICK CONCRETE SLAB 1/8" PLITEQ GENIEMAT RST02 UNDERLAYMENT (AT REQUIRED LOCATIONS) UNDER LVT FLOOR FINISH STC RATING 57 IIC RATING 51 R-11 BATT INSULATION CORRIDOR CORRIDOR HANGER WIRE 4'-0" O.C. MAX 1 1/2" CHANNEL, 4'-0 O.C.,MAX. (MAIN RUNNER) WIRE TIE 1 LAYER 5/8" TYPE 'C' GYP. BD. CEILING HAMBRO MINI JOIST 3" CONCRETE SLAB 1 LAYER 5/8" TYPE 'C' GYP. BD. ON 7/8" FURRING CHANNELSASSEMBLY8 1/2" RATEDLIGHTWEIGHT CONCRETE TOPPING MIN. 2.5" THICK MIN. 1 HOUR RATED PER IBC 2018 SECTION 722.2.1.1 -BROOM FINISH METAL DECKING STAIR METAL POUR STOP STEEL STAIR SUPPORT1' - 1 1/2"7/8" RESILIENT CHANNELS @ 24" O.C. 1 LAYER OF 5/8" TYPE 'X' GYPSUM BOARD EXTERIOR INTERIOR 60 MIL SINGLE PLAY TPO ROOFING MEMBRANE (FULLY ADHERED) OVER 1/2" PROTECTION BOARD 3" CONCRETE TOPPING, SEE STRUCTURAL R-25 CONTINUOUS INSULATION VAPOR BARRIER PER MFR, SEE SPECS MECHANICALLY FASTENED BATT INSULATION HAMBRO JOIST, SEE STRUCTURAL 3" COMPOSITE METAL DECKING WELDED WIRE MESH TAPPERED INSULATION 1/2" PROTECTION BOARD WATERPROOFING MEMBRANE TPO FLASHING TO LAP OVER TPO MEMBRANE AND METAL FLASHING 60 MIL SINGLE PLAY TPO ROOFING MEMBRANE (FULLY ADHERED) OVER PROTECTION BOARD LW CONCRETE TOPPING POST-TENSIONED CONCRETE SLAB SYSTEM, SEE STRUCTURAL DWGS. PROVIDE R-12.5ci (MIN) FACED FIBERGLASS BATT INSULATION STC 50 (MIN) 1/8" PLITEQ GENIEMAT RST02 UNDERLAYMENT (AT REQUIRED LOCATIONS) UNDER LVT FLOOR FINISH LEVEL 6 -UNITS / AMENITIES LEVEL 6 -GARAGE / STORAGE OUTDOOR DECK UNIT HANGER WIRE 4'-0" O.C. MAX 7/8" CHANNEL, 4'-0 O.C.,MAX. (MAIN RUNNER) WIRE TIE 1 LAYER 5/8" TYPE 'C' GYP. BD. CEILING POST-TENSIONED CONCRETE SLAB SYSTEM, SEE STRUCTURAL DWGS. R-13 BATT INSULATION MECHANICALLY FASTENED TO BOTTOM OF CONCRETE1' - 0"0' - 5"0' - 0 1/2"0' - 2"CEILING HEIGHT 9' -0" A.F.F. PAVER ON PEDESTAL, SEE LANDSCAPE R-25 ci CONTINUOUS RIGID INSULATION 215MIL HOT FLUID-APPLIED WATERPROOFING, SEE SPEC FOR MFR (3) 5/8" TYPE 'C' GYP 1/2" RESILIANT CHANNELS 16" O.C. 5/8" TYPE 'C' GYP 2HR RATED FIRE SEALANT STEEL STUDS(2) 5/8" TYPE 'X' GYP C-CHANNEL STUD W/ BATT INSULATION CABLE TRAY, SEE MECH/ELEC DWGS2HR RATED FIRE SEALANT 1" GYPSUM LINER PANEL CORRIDOR CEILING UL U415 UL I514 (3) 5/8" TYPE 'C' GYP 1/2" RESILIANT CHANNELS 16" O.C. 5/8" TYPE 'C' GYP 2HR RATED FIRE SEALANT C-CHANNEL STUDS(2) 5/8" TYPE 'X' GYP C-CHANNEL STUD W/ BATT INSULATION CABLE TRAY, SEE MECH/ELEC DWGS 2HR RATED FIRE SEALANT 1" GYPSUM LINER PANEL CORRIDOR CEILING UL U415 UL I514 METAL J-RUNNERS C-CHANNEL STUD W/ BATT INSULATION CONTINUOUS 5/8" GYP BD. TYPE 'C' UP TO 1 HOUR CEILING ASSEMBLY METAL STUD WALL W/ INSULATION, SEE STRUCTURAL UNDERSIDE OF 1HR CEILING ASSEMBLY UL # L563 PLYWOOD @ SHEAR WALLS ONLY (SEE STRUCTURAL FOR LOCATIONS) 1 LAYER 5/8" GYP BD. TYPE 'C' ON RESILIENT CHANNELS PLYWOOD @ SHEAR WALLS ONLY (SEE STRUCTURAL FOR LOCATIONS) CONTINUOUS 5/8" GYP BD. TYPE 'C' UP TO 1 HOUR CEILING ASSEMBLY METAL STUD WALL W/ INSULATION, SEE STRUCTURAL SD1 149 2X6 2X8 (EXAMPLE) SD1 129 (3) 5/8" TYPE 'C' GYP 1/2" RESILIANT CHANNELS 16" O.C. 5/8" TYPE 'C' GYP 2HR RATED FIRE SEALANT STEEL STUDS(2) 5/8" TYPE 'X' GYP C-CHANNEL STUD W/ BATT INSULATION CABLE TRAY, SEE MECH/ELEC DWGS2HR RATED FIRE SEALANT 1" GYPSUM LINER PANEL CORRIDOR CEILING UL U415 UL I514 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:20 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.75 2247601 FLOOR/CEILING & ROOF/CEILING ASSEMBLY DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL#G524 2 HR FLOOR/ CEILING ASSEMBLY @ UNITFCA-1 UL# G524 2-HR FLOOR/CEILING ASSEMBLY @ CORRIDORFCA-2 FLOOR/CEILING ASSEMBLY @ STAIRFCA-3 UL# G524 1 HR ROOF/CEILING ASSEMBLYRCA-1 UL #D906 2 HR RATED ROOF @ STAIRS & ELEVATORRCA-2 3-HOUR RATED FLOOR/CEILING ASSEMBLYFCA-6 3-HR RATED FLOOR CEILING ASSEMBLY @ OUTDOOR DECKFCA 5 UL U415 B VERTICAL & UL I514 HORIZONTAL HORIZONTAL 2HR RATED HORIZONTAL SHAFTFCA-7 UL U415 B VERTICAL & UL I514 HORIZONTAL HORIZONTAL 2HR RATED HORIZONTAL SHAFT @ GARAGEFCA-8 1 1/2" = 1'-0"1 UL# xxx RATED WALL 1 1/2" = 1'-0"2 UL U415 B VERTICAL & UL I514 HORIZONTAL HORIZONTAL 2HR RATED HORIZONTAL SHAFT1 DATE DESCRIPTION REV 1" GYPCRETE TOPPING FLOOR SHEATHING, SEE STRUCTURAL PREFAB WOOD FLOOR TRUSS, SEE STRUCTURAL DWGS. 1 LAYER 5/8" TYPE 'C' GYP. BD. (DRYWALL SCREWS ARE NOT TO PENETRATE WOOD TRUSS JOISTS) 1/2" RESILIENT CHANNELS @ 12" O.C. BLOWN-IN INSULATION INTERIOR CORRIDIOR INTERIOR CORRIDIOR FLOOR FINISH PER SCHEDULE NOTE: ALTERNATE PER UL #L528, BLOWN -IN INSULATION CAN BE SUBSITUTED WITH R-30 BATT INSULATION AT BOTTOM CHORD OF FLOOR TRUSS. THIS WILL REQUIRE FULLY SPRINKLERING THE INTERSITIAL SPACE. 1 1/2" LIGHTWEIGHT CONCRETE FLOOR SHEATHING, SEE STRUCTURAL 60 MIL WATERPROOFING MEMBRANE 1 LAYER 5/8" TYPE 'C' GYP. BD. (DRYWALL SCREWS ARE NOT TO PENETRATE WOOD TRUSS JOISTS) 1/2" RESILIENT CHANNELS @ 12" O.C. 2X10 WOOD FRAMING SEE STRUCTURAL DWGS STRUCTURE TO SLOPE 1/4" PER 1'-0" EXTERIOR EXTERIOR 2 1/2" -1 1/2" MINIMUM LIGHTWEIGHT CONCRETE FLOOR SHEATHING, SEE STRUCTURAL 12" DEEP PREFAB WOOD FLOOR TRUSS, SEE STRUCTURAL 1 LAYER 5/8" TYPE 'C' GYP. BD. (DRYWALL SCREWS ARE NOT TO PENETRATE WOOD TRUSS JOISTS) 1/2" RESILIENT CHANNELS @ 12" O.C. STAIR STAIR ROOF DECKING, SEE STRUCTURAL PREFAB WOOD ROOF TRUSS, SEE STRUCTURAL 1/2" RESILIENT CHANNELS @ 12" O.C. 1 LAYER OF 5/8" TYPE 'C' GYPSUM BOARD EXTERIOR INTERIOR R-38 MINIMUM, BLOWN-IN FIBERGLASS INSULATION. FULLY FILL ROOF ASSEMBLY 60 MIL. SINGLE PLY TPO ROOF MEMBRANE, FULLY ADHERED 1/4" COVER BOARD, MECHANICALLY FASTENED TAPERED INSULATION, MECHANICALLY FASTENED -R-25 MIN. 1'-8" PREFAB WOOD ROOF TRUSS, SEE STRUCTURAL 1 LAYER 5/8" TYPE 'S' GYP. BD. 'GENIE CLIP RST' BY PLITEQ SKY DECK UNIT TAPERED INSULATION, MECHANICALLY FASTENED -R-25 MIN. ADJUSTABLE PEDESTAL SYSTEM, PROVIDE KINETICS NPS NEOPRENE PADS BENEATH BACK PEDESTAL. WOOD TILE DECKING 80 MIL. SINGLE PLY TPO ROOF MEMBRANE, FULLY ADHERED ROOF DECKING, SEE STRUCTURAL 1/2" COVER BOARD, MECHANICALLY FASTENED 'GENIE MAT FF17' BY PLITEQ 1" GYPCRETE FLOOR SHEATHING, SEE STRUCTURAL DWGS. PREFAB WOOD FLOOR TRUSS, SEE STRUCTURAL DWGS. SOUND ISOLATION MAT 1/4" (REFER TO SHEET CD-88 FOR UL AND A3 SERIES FOR REQUIRED LOCATIONS) BLOWN-IN INSULATION 1 LAYER 5/8" TYPE 'C' GYP. BD. (DRYWALL SCREWS ARE NOT TO PENETRATE WOOD TRUSS JOISTS) INTERIOR OF UNIT INTERIOR OF UNIT 1/2" RESILIENT CHANNELS DELUX @ 12" O.C. FLOOR FINISH PER SCHEDULE 1" GYPCRETE FLOOR SHEATHING, SEE STRUCTURAL DWGS. PREFAB WOOD FLOOR TRUSS, SEE STRUCTURAL DWGS. SOUND ISOLATION MAT 1/4" (REFER TO SHEET CD-88 FOR UL AND A3 SERIES FOR REQUIRED LOCATIONS) BLOWN-IN INSULATION COMPOSITE METAL PANEL SYSTEM EXTERIOR UNIT EXTERIOR SHEATHING FLOOR FINISH PER SCHEDULE AIR / MOISTURE BARRIER C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:23 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.76 2247601 FLOOR/CEILING & ROOF/CEILING ASSEMBLY DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #L528 1-HOUR FLOOR ASSEMBLY AT CORRIDORFCA 2 UL #L528 1-HOUR FLOOR/ CEILING ASSEMBLY AT BALCONYFCA 3 UL #L563 1-HOUR FLOOR/ CEILING ASSEMBLY AT STAIRFCA 4 UL #P522 1-HOUR ROOF/CEILING ASSEMBLY (TPO MEMBRANE)FCA 5 UL #P580 1-HOUR RATED ROOF/CEILING ASSEMBLY AT AMENITYFCA 6 UL #L528 1-HOUR FLOOR/CEILING ASSEMBLY AT UNITFCA 1 UL #L528 1-HOUR FLOOR / CEILING ASSEMBLY AT UNIT AND EXTERIORFCA 7 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:33 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.80 2247601 UL ASSEMBLIES - U210 & U344 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U210 UL #U344 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:41 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.81 2247601 UL ASSEMBLIES- U305 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U305 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:47 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.82 2247601 UL ASSEMBLIES - U301 & D906 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U301 UL #D906 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:55:55 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.83 2247601 UL ASSEMBLIES - U341 & U905 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U341 UL #U905 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:08 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.84 2247601 UL ASSEMBLIES - L528 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #L528 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:25 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.85 2247601 UL ASSEMBLIES - G524 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #G524 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:35 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.86 2247601 UL ASSEMBLIES - L563 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #L563 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:42 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.87 2247601 UL ASSEMBLIES - U415 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U415 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:47 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.88 2247601 UL ASSEMBLIES - P580 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #P580 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:56 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.89 2247601 UL ASSEMBLIES - U419 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U419 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:57:03 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.90 2247601 UL ASSEMBLIES - U420 & U428 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U420 UL #U428 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:57:08 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.91 2247601 UL ASSEMBLIES - V454 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #V454 DATE DESCRIPTION REV C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:57:15 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA00.92 2247601 UL ASSEMBLIES - U425 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCUL #U425 - OPTION 1 UL #U425 - OPTION 2 DATE DESCRIPTION REV LANDDESIGN223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325CONTACT NAME:LANDSCAPE ARCHITECTOWNER/DEVELOPERMILL CREEK RESIDENTIAL101 W. WORTHINGTON AVESUITE 210CHARLOTTE, NC 28203704.565.0835ARCHITECTDWELL DESIGN STUDIO, LLC1910 SOUTH BLVD.SUITE 200CHARLOTTE, NC 28203980.357.9075LANDDESIGN223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325CONTACT NAME:CIVIL ENGINEERVICINITY MAPPROJECT TEAMDATE:11/11/2022 9:20 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_COVR.DWG11.11.2022CHARLOTTE, NCMULTI-FAMILYMODERA AT THE FOUNDRYSCHEMATIC DESIGNCHAPTER INDEXLD PNCOVER1022147MODERA AT THEFOUNDRYC1-00SITE6003000150CE DAR S T .STADIUM VW DR.W. MOREHEAD ST.JOHN BELK FWY.S M INT ST .S GRAHAM ST .SHAUN HICKSMARC MOMSENSheet List TableSheet NumberSheet TitleCH1- GENERALC1-00COVERC1-10OVERALL SITE PLANCH2 - DEMOLITIONC2-00DEMOLITION PLANCH3 - EROSION CONTROLC3-00EROSION CONTROL PH 1C3-01EROSION CONTROL PH 2CH4 - SITEC4-00MATERIALS PLANC4-01PRODUCT SCHEDULECH5 - GRADINGC5-00OVERALL GRADING PLANCH6 - STORMWATERC6-00STORMWATER PLANC6-01STORM PROFILESC6-10STORM DETAILSCH7 - UTILITYC7-00UTILITY PLANC7-10UTILITY DETAILSCH8 - PLANTINGC8-00REQUIRED PLANTING PLAN 8,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 DNSTAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD28,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 DNSTAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD2GENTR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WTTTTTTTR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WXXSOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)EXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINRETAILLEASING/LOBBYPARKINGDECK ENTRYLOADINGRETAIL/EDEERETAILFUTURE 36' CATSRAIL ROWPARCEL NOT PARTOF PROJECT(PARCEL ID 07318310)14' SETBACK 14' SETBACKEXISTINGPARKING TOREMAINRETAILRETAILRETAILFITNESSFUTURE 55' CATSRAIL ROWFUTURE 36' CATSRAIL ROW8,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 DNSTAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD2REQUIRED 5' WIDEEGRESS/FIRE/MAINTENANCE PATHREQUIRED 5' WIDEEGRESS/FIRE/MAINTENANCE PATH20' STORM DRAIN EASEMENT20' STORM DRAIN EASEMENT30' PEDESTRIAN EASEMENT15' SANITARY SEWER EASEMENTINGRESS/EGRESSEASEMENT32' X 205.5'NON-EXCLUSIVEEASEMENTINGRESS/EGRESSEASEMENT30' PEDESTRIAN EASEMENT20' VEHICULAR/PEDESTRIAN EASEMENTMODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147OVERALL SITE PLANN/AC1-1011/11/2022 10:14 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_OVRL.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####9/12/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020010 STSTXXXXXXXXX STSTSTSTGASGASGASGASGASGASGASGASGASGASSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPWWWWWWWWWWWWW WWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWW48.8'3.0'1.5'39.0'50.5'41.9'ST 20'SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTS T STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSTST693680678678670675665665670675680685690695700 710710705700695690685705700690685680675670665670670680665685690695700705705665665SOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147DEMOLITION PLANN/AMMKMKMC2-0011/11/2022 10:28 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_DEMO.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####11/8/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221##############################1" = 20'4020010EX. BLDG., FOOTING, SIDEWALK,AND MISC. STRUCTURES(TO BE REMOVED)EX. CONCRETE/ ASPHALT/GRAVEL (TO BE REMOVED)LEGENDEX. UTILITY POLES, MISC. SITESTRUCTURES (TO BE REMOVED)EX. FENCE AND WALL(TO BE REMOVED)EX. TREES AND SHURBS(TO BE REMOVED)EX. BUILDING TO REMAINEX. BUILDING TO REMAINEX. BUILDING TO REMAINEX. UTILITIES(TO BE REMOVED)EX. STREAM TO BE REROUTEDTHROUGH PROPOSED BOX CULVERT STSTR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSTSTSTSTGASGASGASGASGASGASGASGASGASGASSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPWWWWWWWWWWWWW WWW W WWWWWWWWWWWWWWWW WWWWWWWWWWWWST 20'SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTS T STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSTST693680678678670675665665670675680685690695700 710710705700695690685705700690685680675670665670670680665685690695700705705665665SOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LDLDLDLD661664663 664661665670675665 TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD-> TD-> TD-> TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EROSION CONTROL PH 1N/AMMKMKMC3-0011/11/2022 10:15 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_EROS1.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####11/10/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020#10EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING PLAZATOTAL DENUDED AREA:3.60 ACRESEROSION CONTROL NOTES:1.CONTRACTOR TO PROVIDE AS MUCH SPACE AS POSSIBLE BETWEEN TOE OF FILLSLOPE AND SILT FENCE.2.PLEASE CONTACT CITY INSPECTOR TO ADVISE ON START DATE AND SCHEDULEPRE-CONSTRUCTION MEETING.3.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROMTHE ZONING ADMINISTRATOR.4.ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION SHOWN ON THIS PLAN ISSUBJECT TO A FINE.5.GRADING 1 ACRE OR MORE WITHOUT AN APPROVED EROSION CONTROL PLAN IS AVIOLATION AND SUBJECT TO A FINE.6.ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 7 CALENDAR DAYS.7.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIREDBY THE EROSION CONTROL COORDINATOR.8.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. FILL SLOPES GREATER THAN10' REQUIRE ADEQUATE TERRACING. SLOPES GREATER THAN 3:1 SHALL RECEIVEMATTING.9.ALL ELEVATIONS ARE IN REFERENCE TO THE SURVEYORS BENCHMARK WHICHMUST BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING.10.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE N.C.EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.11.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULDBE CONSTRUCTED AT 3:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENTSLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND ASINDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTEMATERIAL IS HAULED FROM THE PROPERTY THEN THE CONTRACTOR SHALLDISCLOSE THE LOCATION OF ANY ON-SITE AND/OR OFF-SITE BORROW LOCATIONAND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR.BORROW AND WASTE SITES MUST HAVE APPROVE EROSION CONTROL PLAN.12.LIMITS OF CLEARING SHOWN ARE BASED ON CUT AND FILL SLOPES OR OTHERGRADING REQUIREMENTS.13.CONTRACTOR SHALL INSTALL ALL EROSION CONTROL MEASURES AS INDICATEDPRIOR TO GRADING OPERATIONS. NO DEVICE MAY BE REMOVED WITHOUTAPPROVAL OF EROSION CONTROL COORDINATOR.14.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTINGCONTOURS.15.ALL DISTANCES ARE HORIZONTAL GROUND.16.ANCHOR SILT FENCE WITH STONE ON TREE PROTECTION ZONES. DO NOT BURY.17.INLET PROTECTION IS REQUIRED FOR ALL INLETS LOCATED IN THE WORKING AREA18.INLET PROTECTION IS REQUIRED FOR ALL PHASES OF THE PROJECT AND UNTILTHE DISTURBED AREA IS FULLY STABILIZED.19.SEDIMENT TRAP AND BASIN SLOPES SHALL BE STABILIZED AND SEEDEDIMMEDIATELY AFTER CONSTRUCTION.20.CONTRACTOR TO REPLACE ALL STAGING AND STOCKPILE AREAS TO PRECONSTRUCTION CONDITIONS. PROVIDE PHOTO DOCUMENTATION OFPRE-CONSTRUCTION CONDITION AT THESE AREASCONSTRUCTION SEQUENCE1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE CITY OFCHARLOTTE ENGINEERING DEPARTMENT.2.FLAG THE CONSTRUCTION LIMITS AND MARK ANY TREES, WETLANDS, OREXISTING STRUCTURES NOTED TO REMAIN.3.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH EROSION CONTROLINSPECTOR OF THE CITY ENGINEERING DEPARTMENT TO DISCUSS EROSIONCONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURSPRIOR TO ANY LAND-DISTURBING ACTIVITY IS A VIOLATION OF THE CITY CODEAND IS SUBJECT TO FINE.4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE.5.INSTALL ALL TEMPORARY SILT FENCE, TREE PROTECTION, AND ANY OTHERTEMPORARY MEASURES AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.6.INSTALL SKIMMER SEDIMENT BASIN, CHECK DAMS AND DIVERSION DITCHES.7.CALL FOR ON-SITE INSPECTION BY EROSION CONTROL INSPECTOR. WHENAPPROVED, INSPECTOR WILL ISSUE THE GRADING PERMIT AND CLEARING,GRUBBING AND DEMOLITION MAY BEGIN.8.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES AREIN PLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS.9.BEGIN CLEARING, GRUBBING AND DEMOLITION OPERATIONS. CLEARING ANDGRUBBING SHALL BE DONE ONLY IN AREAS WHERE EARTHWORK WILL BEPERFORMED AND ONLY IN AREAS WHERE CONSTRUCTION IS PLANNED TOCOMMENCE WITHIN 14 DAYS AFTER CLEARING AND GRUBBING.10.BEGIN MASS GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURESAS INDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSIONCONTROL INSPECTOR.11.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDINGIS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS ANDESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTIONSEQUENCE.12.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED AND WITH APPROVALFROM EROSION CONTROL INSPECTOR.13.ALL EROSION CONTROL DEVICES SHOULD BE MONITORED ONCE A WEEK ANDAFTER EVERY STORM EVENT OF 6" OR GREATER BY A CERTIFIED INSPECTOR. IFANY FAILURES ARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE.14.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCEWITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGNMANUAL, U.S. DEPT. OF AGRICULTURE, CITY OF CHARLOTTE, EROSION CONTROLORDINANCE, AND THE CHARLOTTE MECKLENBURG LAND DEVELOPMENTSTANDARDS.15.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENTPROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING,PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.16.UPON STABILIZATION OF ALL UPSTREAM AREA, SKIMMER SEDIMENT BASIN TO BEMUCKED OUT AND FILLED. (PHASE 3)LIMITS OF DISTURBANCELEGENDLDLDTEMPORARY SILT FENCE (CLDS 30.06A)PROPOSED BAFFLESPROPERTY LINEPROPOSED STABILIZED CONSTRUCTIONENTRANCE (CLDS 30.11A)INLET PROTECTIONSKIMMER SEDIMENT BASIN (SSB 1)DRAINAGE AREA : 3.10 ACSURFACE AREA REQUIRED: 6,729 SFSURFACE AREA PROVIDED: 7,145 SFVOLUME PROVIDED: 15,120 CFBOTTOM OF BASIN: 661'SIDE SLOPE: 3:1PROP. SKIMMER DEWATERINGDEVICESKIMMER SIZE: 2.00"ORIFICE DIAMETER: 1.50"SKIMMER INVERT: 662.00'DE-WATERING TIME: 7.13 DAYSPROP. BAFFLESPROP. 12" PVC TO TIEINTO EX. STORM INLETPROP. 12" PVC (TYP.)PROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)PROP. SLOPE DRAINPIPE (TYP.)EX. STORMWATER (TYP.)PROP. LIMITS OFDISTURBANCE(TYP.)PROP. TRIPLE ROWSILT FENCE (TYP.)EX. SANITARYSEWER (TYP.)EX. STORMWATER (TYP.)PROP. TEMPORARY DIVERSIONDITCH WITH ROCK CHECK DAMSEVERY 50 LF (TYP.)PROP. TEMPORARY DIVERSIONDITCH WITH ROCK CHECK DAMSEVERY 50 LF (TYP.)PROP. LIMITS OFDISTURBANCE (TYP.)DRAINAGE AREADRAINAGE AREAPROPERTY LINEPROPERTY LINE R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSTSTSTSTGASGASGASGASGASGASGASGASGASGASSTSTSTSTSTSTUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPWWWWWWWWWWWWW WWW W WWWWWWWWWWWWWWWW WWWWWWWWWWWWSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSS693680678678670675665665670675680685690695700 710710705700695690685705700690685680675670665670670680665685690695700705705665665SOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LDLDLDLD666.00 FG662.93 EX TC663.32 FG664.15 EX FG665.53 EX FG665.35 EX FG665.22 EX FG665.84 EX FG665.98 EX FG666.03 EX FG664.82 EX FG665.70 RIM666.00 FG669.50 TS666.00 BS670.20 BS674.20 TS674.60 BS678.60 TS682.00 FG681.11 FG4.3%1.7%665.74 EX FG666.61 EX FG666.00 BS665.86 RIM0.1%0.6%663.63 EX TC665.74 EX TC675.00 EX TC685.80 EX TC685.65 EX BC668.61 FG0.4%1.7%688.00 EX TC687.70 EX BC689.03 FG689.14 FG689.77 FG691.80 EX TC691.50 EX BC692.19 FG699.00 EX TC698.61 EX BC697.85 FG697.95 FG698.71 FG670675680685690700.80 FG696.80 EX TC696.50 EX BC699.11 FG699.21 FG699.37 FG692.00 FG692.06 FG702.11 FG688686683678673668688.00 FG695697687.87 EX FG701.00 FG705.08 FG701702703704705 705706707708709706 707 70 8 666.00 FG666.00 BS669.50 TS1.5%670.20 BS1.9%674.20 TS674.60 BS678.24 TS1.7%677.69 EX FG677.83 EX FG677.78 EX FG677.66 EX FG677.84 EX FG679.50 BC680.00 TC678.40 BC678.90 TC678.34 FG1.5%0.8%678.00 TC678.96 FG1.5%0.5%1.9%1.1%0.3%1.7%3.1%3.3%680.75 FG3.0%680.96 FG678.79 FG1.0%0.9%4.3%687.00 FG4.5%681.00 FG4.8%686.00 FG686.16 FG686.42 FG690.00 FG5.0%665.90 FG665.95 FG1.5%0. 7 % 0.8 %1.1%1.9%0.7%0.4%665.11 FG665.69 FG1.9%663.50 TC1.4%0.7%663.88 FG664.00 FG686.00 FG683.00 FG683.65 FG684.57 TS685.02 TS9.9%6.4%6.3%1.9%685.06 FG13.8%1.8%5.0%1.0%1.0%2.7%1.0%1.7%4.8%5.0%1.7%700.05 FG701.00 FG700.19 FG702.03 FG4.7%702.14 FG705.00 FG704.00 FG4.8%706.00 FG706.00 FG705.00 FG1.1%4.6%706.08 FG705.53 FG2.5%2 . 5%664663665665674674MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EROSION CONTROL PH 2N/AMMKMKMC3-0111/11/2022 10:15 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_EROS2.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####11/10/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020#10EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING PLAZATOTAL DENUDED AREA:3.60 ACRESEROSION CONTROL NOTES:1.CONTRACTOR TO PROVIDE AS MUCH SPACE AS POSSIBLE BETWEEN TOE OF FILLSLOPE AND SILT FENCE.2.PLEASE CONTACT CITY INSPECTOR TO ADVISE ON START DATE AND SCHEDULEPRE-CONSTRUCTION MEETING.3.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROMTHE ZONING ADMINISTRATOR.4.ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION SHOWN ON THIS PLAN ISSUBJECT TO A FINE.5.GRADING 1 ACRE OR MORE WITHOUT AN APPROVED EROSION CONTROL PLAN IS AVIOLATION AND SUBJECT TO A FINE.6.ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 7 CALENDAR DAYS.7.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIREDBY THE EROSION CONTROL COORDINATOR.8.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. FILL SLOPES GREATER THAN10' REQUIRE ADEQUATE TERRACING. SLOPES GREATER THAN 3:1 SHALL RECEIVEMATTING.9.ALL ELEVATIONS ARE IN REFERENCE TO THE SURVEYORS BENCHMARK WHICHMUST BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING.10.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE N.C.EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.11.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULDBE CONSTRUCTED AT 3:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENTSLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND ASINDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTEMATERIAL IS HAULED FROM THE PROPERTY THEN THE CONTRACTOR SHALLDISCLOSE THE LOCATION OF ANY ON-SITE AND/OR OFF-SITE BORROW LOCATIONAND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR.BORROW AND WASTE SITES MUST HAVE APPROVE EROSION CONTROL PLAN.12.LIMITS OF CLEARING SHOWN ARE BASED ON CUT AND FILL SLOPES OR OTHERGRADING REQUIREMENTS.13.CONTRACTOR SHALL INSTALL ALL EROSION CONTROL MEASURES AS INDICATEDPRIOR TO GRADING OPERATIONS. NO DEVICE MAY BE REMOVED WITHOUTAPPROVAL OF EROSION CONTROL COORDINATOR.14.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTINGCONTOURS.15.ALL DISTANCES ARE HORIZONTAL GROUND.16.ANCHOR SILT FENCE WITH STONE ON TREE PROTECTION ZONES. DO NOT BURY.17.INLET PROTECTION IS REQUIRED FOR ALL INLETS LOCATED IN THE WORKING AREA18.INLET PROTECTION IS REQUIRED FOR ALL PHASES OF THE PROJECT AND UNTILTHE DISTURBED AREA IS FULLY STABILIZED.19.SEDIMENT TRAP AND BASIN SLOPES SHALL BE STABILIZED AND SEEDEDIMMEDIATELY AFTER CONSTRUCTION.20.CONTRACTOR TO REPLACE ALL STAGING AND STOCKPILE AREAS TO PRECONSTRUCTION CONDITIONS. PROVIDE PHOTO DOCUMENTATION OFPRE-CONSTRUCTION CONDITION AT THESE AREASCONSTRUCTION SEQUENCE1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE CITY OFCHARLOTTE ENGINEERING DEPARTMENT.2.FLAG THE CONSTRUCTION LIMITS AND MARK ANY TREES, WETLANDS, OREXISTING STRUCTURES NOTED TO REMAIN.3.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH EROSION CONTROLINSPECTOR OF THE CITY ENGINEERING DEPARTMENT TO DISCUSS EROSIONCONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURSPRIOR TO ANY LAND-DISTURBING ACTIVITY IS A VIOLATION OF THE CITY CODEAND IS SUBJECT TO FINE.4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE.5.INSTALL ALL TEMPORARY SILT FENCE, TREE PROTECTION, AND ANY OTHERTEMPORARY MEASURES AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.6.INSTALL SKIMMER SEDIMENT BASIN, CHECK DAMS AND DIVERSION DITCHES.7.CALL FOR ON-SITE INSPECTION BY EROSION CONTROL INSPECTOR. WHENAPPROVED, INSPECTOR WILL ISSUE THE GRADING PERMIT AND CLEARING,GRUBBING AND DEMOLITION MAY BEGIN.8.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES AREIN PLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS.9.BEGIN CLEARING, GRUBBING AND DEMOLITION OPERATIONS. CLEARING ANDGRUBBING SHALL BE DONE ONLY IN AREAS WHERE EARTHWORK WILL BEPERFORMED AND ONLY IN AREAS WHERE CONSTRUCTION IS PLANNED TOCOMMENCE WITHIN 14 DAYS AFTER CLEARING AND GRUBBING.10.BEGIN MASS GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURESAS INDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSIONCONTROL INSPECTOR.11.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDINGIS NECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS ANDESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTIONSEQUENCE.12.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED AND WITH APPROVALFROM EROSION CONTROL INSPECTOR.13.ALL EROSION CONTROL DEVICES SHOULD BE MONITORED ONCE A WEEK ANDAFTER EVERY STORM EVENT OF 6" OR GREATER BY A CERTIFIED INSPECTOR. IFANY FAILURES ARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE.14.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCEWITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGNMANUAL, U.S. DEPT. OF AGRICULTURE, CITY OF CHARLOTTE, EROSION CONTROLORDINANCE, AND THE CHARLOTTE MECKLENBURG LAND DEVELOPMENTSTANDARDS.15.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENTPROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING,PERMISSION MUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.16.UPON STABILIZATION OF ALL UPSTREAM AREA, SKIMMER SEDIMENT BASIN TO BEMUCKED OUT AND FILLED. (PHASE 3)LIMITS OF DISTURBANCELEGENDLDLDTEMPORARY SILT FENCE (CLDS 30.06A)PROPOSED BAFFLESPROPERTY LINEPROPOSED STABILIZED CONSTRUCTIONENTRANCE (CLDS 30.11A)INLET PROTECTIONPROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)PROP. LIMITS OFDISTURBANCE (TYP.)PROP. TRIPLE ROW SILTFENCE (TYP.)EX. SANITARYSEWER (TYP.)EX. STORMWATER(TYP.)PROP. LIMITS OFDISTURBANCE (TYP.)EXCAVATION TO BECOLLECTED IN SUMP ANDDISCHARGED TO EX. DITHROUGH DIRT BAGFFE: 665'FFE: 665'FFE: 674' - 3"PROPOSED BUILDING (FORREFERENCE ONLY)ELEVATIONS ARE TO TOP OFFINISHED GRADE. CONTRACTOR TOSUBTRACT PAVEMENT AND/OR SLABSECTION. CUT 1' TO SUB-GRADE.FFE'S PER ARCHITECTURAL GROUNDFLOOR PLAN.PROPERTY LINEPROPERTY LINE R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/W8,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD28,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD2GENTR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WTTTTTTTSOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)EXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINRETAILLEASING/LOBBYPARKINGDECK ENTRYLOADINGRETAIL/EDEERETAILFUTURE 36' CATSRAIL ROWPARCEL NOT PARTOF PROJECT(PARCEL ID 07318310)14' SETBACK 14' SETBACKEXISTINGPARKING TOREMAINRETAILRETAILRETAILFITNESSFUTURE 55' CATSRAIL ROWFUTURE 36' CATSRAIL ROWST-101BA-101EL-101PV-05ASW-101APV-06APA-101PV-02BPV-02APV-02A01-0101-0102-0102-0102-0202-0201-0201-0201-0201-02POTENTIAL FOR DRIVEWAYIMPROVEMENTS IN THISZONEUPGRADE EXISTINGROADWAY LIGHT TO DUKELEDPV-03APV-03APV-04APV-04APV-04APV-04ASF-101SF-101SF-101PV-0750' x 50' SIGHTTRIANGLE10' x 10' PEDESTRIANSIGHT TRIANGLE10' x 10' PEDESTRIANSIGHT TRIANGLEPV-02BPV-02BEL-101PA-101PA-101PA-101PA-101PV-02APV-02ASF-102BA-102SF-101PV-06BPA-101SW-102APV-03BPV-03BPV-03BPV-03BPV-03BPV-03CPROVIDE TREEUPLIGHTINGPROVIDE TREEUPLIGHTINGPROVIDE TREEUPLIGHTINGPROVIDE TREEUPLIGHTINGPROVIDE TREEUPLIGHTINGEL-102PV-03DSF-103EL-101EL-101EL-101PV-05BPV-02A02-03PV-02APV-05BSW-102BPV-08PV-06BPV-02APV-08PV-06BTIE TOEXISTING TRAILSW-101BPV-03B01 EXISTING CONDITIONS TO REMAINSYMBOLDESCRIPTIONDETAILEXISTING CONCRETE CURB AND GUTTER TO REMAINEXISTING POWER POLES TO REMAIN02 GENERAL IMPROVEMENTSSYMBOLDESCRIPTIONDETAILTIE INTO EXISTING CURB-GUTTERTYPE II MODIFIED DRIVEWAYPROPOSED TRANSFORMER LOCATIONBARRIERS, FENCING, RAILINGSSYMBOLDESCRIPTIONDETAILSTAINLESS STEEL DECORATIVE HANDRAIL W/ LED LIGHTINGSTAINLESS CABLE RAILING W/ IPE TOPELECTRICAL, SITE LIGHTINGSYMBOLDESCRIPTIONDETAILPEDESTRIAN POLE LIGHT TYPE IOVERHEAD CATENARY LIGHTINGPLANTING, LANDSCAPESYMBOLDESCRIPTIONDETAILPLANTING AREA TYP.PAVEMENTSSYMBOLDESCRIPTIONDETAILCONCRETE PAVING - PEDESTRIAN RATEDCONCRETE PAVING - VEHICULAR RATEDCURB - 2C-6" CONCRETE CURB + GUTTERCURB - PRECAST CONCRETE VERTICAL CURBCURB - CIP CONCRETE VERTICAL CURBCURB - 18" FLUSH RIBBON CURBSUSPENDED SLAB PAVEMENTPEDESTRIAN PAVER - TYPE IPEDESTRIAN PAVER - TYPE IIVEHICULAR PAVER - TYPE IVEHICULAR PAVER - TYPE IIRAMP - ACCESSIBLERIVER ROCKSITE FURNITURESYMBOLDESCRIPTIONDETAIL5C SQUARE TREE GRATEDECORATIVE PLANTERCONCRETE CURB STOPSTEPSSYMBOLDESCRIPTIONDETAILPRECAST CONCRETE STAIRSITE WALLS, EMBANKMENTSSYMBOLDESCRIPTIONDETAILSITE WALL - TYPE ISITE WALL - TYPE IITRANSFORMER ENCLOSURE WITH DECORATIVE GATESGENERATOR ENCLOSURE WITH DECORATIVE GATES01-0101-0202-0102-0202-03BA-101BA-102EL-101EL-102PA-101PV-02APV-02BPV-03APV-03BPV-03CPV-03DPV-04APV-05APV-05BPV-06APV-06BPV-07PV-08SF-101SF-102SF-103ST-101SW-101ASW-101BSW-102ASW-102BREFERENCE NOTES SCHEDULEMODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147MATERIALS PLANN/AC4-0011/11/2022 10:16 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_MATR.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####10/20/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020010 01 EXISTING CONDITIONS TO REMAINSYMBOLDESCRIPTIONDETAILREMARKSEXISTING CONCRETE CURB AND GUTTER TO REMAINEXISTING POWER POLES TO REMAIN02 GENERAL IMPROVEMENTSSYMBOLDESCRIPTIONDETAILREMARKSTIE INTO EXISTING CURB-GUTTERTYPE II MODIFIED DRIVEWAYPROPOSED TRANSFORMER LOCATIONBARRIERS, FENCING, RAILINGSSYMBOLDESCRIPTIONDETAILVENDORPRODUCTSIZECOLORFINISHREMARKSSTAINLESS STEEL DECORATIVE HANDRAIL W/ LED LIGHTINGSTAINLESS CABLE RAILING W/ IPE TOPCUSTOMELECTRICAL, SITE LIGHTINGSYMBOLDESCRIPTIONDETAILVENDORPRODUCTSIZECOLORFINISHREMARKSPEDESTRIAN POLE LIGHT TYPE IDUKE ENERGYENTERPRISETBDTBD*LEASED AND INSTALLED BY DUKE ENERGY, INCLUDE METAL POLEOVERHEAD CATENARY LIGHTINGLANDSCAPEFORMSARNEPROVIDE ALL REQUIRED CABLE AND SUPPORTSPLANTING, LANDSCAPESYMBOLDESCRIPTIONDETAILVENDORPRODUCTSIZECOLORFINISHREMARKSPLANTING AREA TYP.CONTRACTORREFER TO CHAPTER 8 FOR PLANTING PLANS AND DETAILSPAVEMENTSSYMBOLDESCRIPTIONDETAILVENDORPRODUCTSIZECOLORFINISHREMARKSCONCRETE PAVING - PEDESTRIAN RATEDN/ACONCRETEPER DETAILNATURAL GREYM. BROOMSAW CUT JOINTSCONCRETE PAVING - VEHICULAR RATEDCONTRACTORN/ASTANDARDCURB - 2C-6" CONCRETE CURB + GUTTERCURB - PRECAST CONCRETE VERTICAL CURBHANOVERROCKCURBCURB - CIP CONCRETE VERTICAL CURBCURB - 18" FLUSH RIBBON CURBSUSPENDED SLAB PAVEMENTPEDESTRIAN PAVER - TYPE IUNILOCKARTLINEPAVERS TO BE SET ON CONCRETE SLABPEDESTRIAN PAVER - TYPE IIUNILOCKGRANITOPAVERS TO BE SET ON CONCRETE SLABVEHICULAR PAVER - TYPE IUNILOCKSERIESPAVERS TO BE SET ON CONCRETE SLABVEHICULAR PAVER - TYPE IIUNILOCKSERIESPAVERS TO BE SET ON CONCRETE SLABRAMP - ACCESSIBLEREFER TO CLDSM DETAILRIVER ROCKSITE FURNITURESYMBOLDESCRIPTIONDETAILVENDORPRODUCTSIZECOLORFINISHREMARKS5C SQUARE TREE GRATEURBAN ACCESSORIESCASCADE5C SQ.RUST CONDITIONERDUCTILE IRON MATERIALDECORATIVE PLANTERKORNEGAY DESIGNTBDTBDPROVIDE IRRIGATIONCONCRETE CURB STOPSTEPSSYMBOLDESCRIPTIONDETAILVENDORPRODUCTSIZECOLORFINISHREMARKSPRECAST CONCRETE STAIRCONTRACTORSITE WALLS, EMBANKMENTSSYMBOLDESCRIPTIONDETAILTYPECONSTRUCTIONHEIGHTWALL CAPFINISHDESIGN BYSITE WALL - TYPE IRETAININGCAST-IN-PLACEVARIESSMOOTH-RUBBEDTO BE DESIGNED BY STRUCTURAL ENGINEER, WALL TO SLOPE WITH STAIRSSITE WALL - TYPE IIRETAININGCAST-IN-PLACEVARIESSMOOTH-RUBBEDTRANSFORMER ENCLOSURE WITH DECORATIVE GATESBRICK VENEER8CGENERATOR ENCLOSURE WITH DECORATIVE GATESBRICK VENEERCMU BLOCK8CROWLOCK01-0101-0202-0102-0202-03BA-101BA-102EL-101EL-102PA-101PV-02APV-02BPV-03APV-03BPV-03CPV-03DPV-04APV-05APV-05BPV-06APV-06BPV-07PV-08SF-101SF-102SF-103ST-101SW-101ASW-101BSW-102ASW-102BREFERENCE NOTES SCHEDULEMODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147PRODUCT SCHEDULEN/AC4-0111/11/2022 10:16 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_MATR.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####10/20/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 N/A R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WXXXUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPXX693680678678675665665670675680685690695700705710 7107107057006956906857057006906856806756706656706706806656856906957007057056656658,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD28,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD2R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WTTTTTT666.00 FG662.93 EX TC663.32 FG664.15 EX FG665.53 EX FG665.35 EX FG665.22 EX FG665.84 EX FG665.98 EX FG666.03 EX FG664.82 EX FG665.70 RIM666.00 FG669.50 TS666.00 BS670.20 BS674.20 TS674.60 BS678.60 TS682.00 FG681.11 FG4.3%1.7%665.74 EX FG666.61 EX FG666.00 BS665.86 RIM0.1%0.6%663.63 EX TC665.74 EX TC675.00 EX TC685.80 EX TC685.65 EX BC668.61 FG0.4%1.7%CEDAR STREETSTADIUM VIEW DRIVE688.00 EX TC687.70 EX BC689.03 FG689.14 FG689.77 FG691.80 EX TC691.50 EX BC692.19 FG699.00 EX TC698.61 EX BC697.85 FG697.95 FG698.71 FG670675680685690700.80 FG696.80 EX TC696.50 EX BC699.11 FG699.21 FG699.37 FG692.00 FG692.06 FG702.11 FG688686683678673668688.00 FG695697687.87 EX FG701.00 FG705.08 FG701702703704705 705706707708709706 707 70 8 666.00 FG666.00 BS669.50 TS1.5%670.20 BS1.9%674.20 TS674.60 BS678.24 TS1.7%677.69 EX FG677.83 EX FG677.78 EX FG677.66 EX FG677.84 EX FG679.50 BC680.00 TC678.40 BC678.90 TC678.34 FG1.5%0.8%678.00 TC678.96 FG1.5%0.5%1.9%1.1%0.3%1.7%3.1%3.3%680.75 FG3.0%680.96 FG678.79 FG1.0%0.9%4.3%687.00 FG4.5%681.00 FG4.8%686.00 FG686.16 FG686.42 FG690.00 FG5.0%665.90 FG665.95 FG1.5%0. 7% 0.8 %1.1%1.9%0.7%0.4%665.11 FG665.69 FG1.9%663.50 TC1.4%0.7%663.88 FG664.00 FG686.00 FG683.00 FG683.65 FG684.57 TS685.02 TS9.9%6.4%6.3%1.9%685.06 FG13.8%1.8%5.0%1.0%1.0%2.7%1.0%1.7%4.8%5.0%1.7%700.05 FG701.00 FG700.19 FG702.03 FG4.7%702.14 FG705.00 FG704.00 FG4.8%706.00 FG706.00 FG705.00 FG1.1%4.6%706.08 FG705.53 FG2.5%2 . 5%MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147OVERALL GRADING PLANN/AMMKMKMC5-0011/11/2022 10:17 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_GRAD.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####10/21/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020010 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSTSTSTSTGASGASGASGASGASGASGASGASGASGASSTSTSTSTSTSTUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPWWWWWWWWWWWWW WWW W WWWWWWWWWWWWWWWW WWWWWWWWWWWWSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSS693680678678670675665665670675680685690695700 7107107057006956906857057006906856806756706656706706806656856906957007057056656658,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD28,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD2GENTR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WTTTTTTT666.00 FG662.93 EX TC663.32 FG664.15 EX FG665.53 EX FG665.35 EX FG665.22 EX FG665.84 EX FG665.98 EX FG666.03 EX FG664.82 EX FG665.70 RIM666.00 FG669.50 TS666.00 BS670.20 BS674.20 TS674.60 BS678.60 TS682.00 FG681.11 FG665.74 EX FG666.61 EX FG666.00 BS665.86 RIM663.63 EX TC665.74 EX TC675.00 EX TC685.80 EX TC685.65 EX BC668.61 FG688.00 EX TC687.70 EX BC689.03 FG689.14 FG689.77 FG691.80 EX TC691.50 EX BC692.19 FG699.00 EX TC698.61 EX BC697.85 FG697.95 FG698.71 FG670675680685690700.80 FG696.80 EX TC696.50 EX BC699.11 FG699.21 FG699.37 FG692.00 FG692.06 FG702.11 FG688686683678673668688.00 FG695697687.87 EX FG701.00 FG705.08 FG701702703704705 705706707708709706 707 70 8 666.00 FG666.00 BS669.50 TS670.20 BS674.20 TS674.60 BS678.24 TS677.69 EX FG677.83 EX FG677.78 EX FG677.66 EX FG677.84 EX FG679.50 BC680.00 TC678.40 BC678.90 TC678.34 FG678.00 TC678.96 FG680.75 FG680.96 FG678.79 FG687.00 FG681.00 FG686.00 FG686.16 FG686.42 FG690.00 FG665.90 FG665.95 FG665.11 FG665.69 FG663.50 TC663.88 FG664.00 FG686.00 FG683.00 FG683.65 FG684.57 TS685.02 TS685.06 FG700.05 FG701.00 FG700.19 FG702.03 FG702.14 FG705.00 FG704.00 FG706.00 FG706.00 FG705.00 FG706.08 FG705.53 FG0+000+501+001+502+002+05S-9S-12S-10S-11SDMH - 1CB - 1DI - 2DI - 1SDCO - 1SDCO - 2SDMH - 26'x6' RCB6'x6' RCB6'x6' RCB18" R C P18" RCP18" RCP18" R C P18" RCP10" HDPE10" HDPE 10" HDPESOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)EXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINRETAILLEASING/LOBBYPARKINGDECK ENTRYLOADINGRETAIL/EDEERETAILFUTURE 36' CATSRAIL ROWPARCEL NOT PARTOF PROJECT(PARCEL ID 07318310)14' SETBACK 14' SETBACKEXISTINGPARKING TOREMAINRETAILRETAILRETAILFITNESSFUTURE 55' CATSRAIL ROWFUTURE 36' CATSRAIL ROWMODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147STORMWATER PLANN/A MM KM KMC6-0011/11/2022 10:18 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_STRM.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####11/10/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020010E X . 2 0 ' S TO RMW A T E R E A S EM E N T PROP. 30'STORMWATEREASEMENTEX. WATER (TYP.)EX. WATER (TYP.)EX. STORM (TYP.)PROPERTY LINEPROPERTY LINEEX. 6'X6' BOX CULVERTEX. SANITARY SEWER (TYP.)TIE TO EX. 12" RCP STORMPROP. TRENCH DRAINPROP. 6'X6' BOX CULVERT.TIE TO EX. CULVERT.PROP. 6'X6' BOX CULVERT.TIE TO EX. CULVERT.EX. STORM TO REMAIN (TYP.)EX. STORM TO REMAIN (TYP.)PROP. ROOF LEADER CONNECTIONPROP. 4" PERFORATED PIPE (TYP.)PROP. 4" PERFORATED PIPE (TYP.)TIE FOUNDATION DRAINAGE TO STORM SYSTEM4" PVCTREE PIT DRAIN (TYP.)PROP. UNDERGROUND DETENTIONCHAMBERSURFACE AREA: 4,000 SFTOTAL VOLUME PROVIDED: 28,000 CF PROFILE - PROP BOX CULVERTSCALE: 1" = 20' H & 1" = 2' V6556606656706756806856556606656706756806850+00668.85668.850+50668.49668.491+00676.10676.10 1+50679.77 679.77 2+00681.00 681.00 2+50S-10RIM: 677.0072" INV. IN: 666.00 (S-12)72" INV. OUT: 662.45 (S-11)S-12RIM: 679.3272" INV. IN: 668.18 (S-9)72" INV. OUT: 668.18 (S-10)S-9RIM: 681.0872" INV. OUT: 672.40 (S-12)S-11RIM: 669.8872" INV. IN: 661.46 (S-10)72" INV. IN: 661.46 ()72" INV. OUT: 661.46 ()MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147STORM PROFILES1" = 2'MMKMKMC6-0111/11/2022 10:18 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PRO_STRM.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####11/3/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020010PROP. GRADEEX. GRADE MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147STORM DETAILSN/AMMKMKMC6-1011/11/2022 10:18 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_DTL_STRM.DWGAS NOTEDKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####9/12/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 DUCTILE IRONDO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLASTHDPE LEADER TO BUILDINGDOWNSPOUT @ MINIMUM 1.00% SLOPE,SEE ROOF DRAINAGE DOWNSPOUTCONNECTION DETAILHEADER / STORM DRAINAGE LINE,SEE PLANS FOR SIZE AND MATERIALTEE-WYE CONNECTIONINLINE DRAIN BASIN (IFNECESSARY) - SEE PLANS FORLOCATION, GRATE, AND SIZEFLOW DIRECTIONFLOW DIRECTIONDUCTILE IRON DO NOT POLLUTE DRAINS TO WATERWAYSNYLOPLASTHDPE LEADER TO BUILDINGDOWNSPOUT @ MINIMUM 1.00% SLOPE45° BEND45° WYE ANDREDUCER TO 4"GASKETEDCONNECTIONREDUCER ASNECESSARY90° BEND6" PIPE4" CLEANOUT END CAPINSTALLED FLUSHWITH GRADEDOWNSPOUT ADAPTER INSERTED INRISER PIPE(GROUT CONNECTION WATERTIGHT)DOWNSPOUTHDPE ORPVC PIPEREDUCER ASNECESSARYHEADER PIPE, SEEPLANS FOR SIZEAND MATERIALWYE AND45° BENDBUILDINGROOF DRAINAGE HEADER/STORM DRAINAGE LINEPLANNTSROOF DRAINAGE DOWNSPOUT CONNECTIONSECTIONNTS1C6-102C6-10 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WSTSTSTSTGASGASGASGASGASGASGASGASGASGASSTSTSTSTSTSTUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPWWWWWWWWWWWWW WWW W WWWWWWWWWWWWWWWW WWWWWWWWWWWWSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSS8,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD28,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD2R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WTTTTTTSOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)EXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINRETAILLEASING/LOBBYPARKINGDECK ENTRYLOADINGRETAIL/EDEERETAILFUTURE 36' CATSRAIL ROWPARCEL NOT PARTOF PROJECT(PARCEL ID 07318310)14' SETBACK 14' SETBACKEXISTINGPARKING TOREMAINRETAILRETAILRETAILFITNESSFUTURE 55' CATSRAIL ROWFUTURE 36' CATSRAIL ROWSSMH - 1RIM: 694.528" INV. IN: 684.00 (SSCO - 1)8" INV. IN: 683.72 (S-20)8" INV. OUT: 683.52 (SSMH - 2)8" PVCSSCO - 1RIM: 695.288" INV. OUT: 685.00 (SSMH - 1)SSMH - 2RIM: 670.328" INV. IN: 663.55 (SSCO - 2)8" INV. IN: 663.55 (SSMH - 1)8" INV. OUT: 663.35 (S-21)8" PVCSSCO - 2RIM: 666.468" INV. OUT: 663.94 (SSMH - 2)MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147UTILITY PLANN/A MM KM KMC7-0011/14/2022 1:16 PM MARC MOMSEN P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_UTIL.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####11/10/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020010E X . 2 0 ' S T ORMW A T E R E A S E M EN T PROP. 30'STORMWATEREASEMENTPROP. STORM (TYP.)EX. WATER (TYP.)EX. 6" WATER MAINAPPROX. LOCATIONOF EX. 6" WATER MAINEX. 8" SANITARY SEWER MAINEX. 18" SANITARY SEWER MAINEX. 24" SANITARY SEWER MAINPROP. 4' DOGHOUSE MANHOLEPROP. 4' DOGHOUSE MANHOLEINTERNAL 1" REDUCED PRESSURE PRINCIPLEBACKFLOW PREVENTION ASSEMBLY PER CLTWATERREQUIREMENTS. SEE DETAIL ON SHEET C7-10. REFERTO PLUMBING FOR ADDITIONAL INFORMATION.PROP. 2" IRRIGATION CONNECTION2" G.V. 6" X 2" TAPPING SADDLE1 - 2" IRRIGATION METERSEE DETAIL ON SHEET C7-10PROP. 6" FIRE LINE1 - 6" X 6" TAPPING SLEEVE & VALVEPROP. 6" FIRE LINE ASSEMBLY W/1" DETECTOR METER.SEE DETAIL ON SHEET C7-10INTERNAL 6" REDUCED PRESSURE PRINCIPLE BACKFLOWPREVENTION ASSEMBLIES PER CLTWATER REQUIREMENTS.1 - 6" FIRESEE DETAIL ON SHEET C7-10. REFER TO PLUMBING FORADDITIONAL INFORMATION.INTERNAL 6" REDUCED PRESSURE PRINCIPLE BACKFLOWPREVENTION ASSEMBLIES PER CLTWATER REQUIREMENTS.1 - 6" DOMESTICSEE DETAIL ON SHEET C7-10. REFER TO PLUMBING FORADDITIONAL INFORMATION.PROP. 6" DOMESTIC CONNECTION6" G.V. 6" X 6" TAPPING SLEEVEAND VALVE1 - 6" COMPOUND METERSEE DETAIL ON SHEET C7-10PROP. TRANSFORMERLOCATIONSPROP. GENERATORLOCATIONPROP. TRANSFORMERLOCATIONSEX. STORM (TYP.)PROPERTY LINEPROPERTY LINEEX. 6'X6' BOX CULVERTPROPOSED DROPPOLEPROPOSED DROPPOLEPROPOSED ELECTRICMANHOLEPROPOSED TELECOMMANHOLEPROPOSED TELECOM MANHOLERECONNECTION TO EXISTING BUILDNGSPROPOSED TELECOM MANHOLERECONNECTION TO EXISTING BUILDNGSPROPOSED DROPPOLEPROP. TRANSFORMERPROPOSED OFFSITE TRANSFORMERTO SERVE EXISTING BUILDINGSON STADIUM VIEW DRIVEPROPOSED ELECTRICMANHOLEPROPOSED DUCT BANKELEC - NINE WAY 6" CONDUITSTELE FOUR WAY 4" CONDUITSPROPOSED DUCT BANKELEC - NINE WAY 6" CONDUITSTELE FOUR WAY 4" CONDUITSPROPOSED DUCT BANKELEC - NINE WAY 6" CONDUITSTELE FOUR WAY 4" CONDUITSPROPOSED DUCT BANKELEC - FIFTEEN WAY 6" CONDUITSTELE - SIX WAY 4" CONDUITS MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147UTILITY DETAILSN/AMMKMKMC7-1011/11/2022 10:19 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_DTL_UTIL.DWGAS NOTEDKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####9/12/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WXXXUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPXX W W W W W SSSSSSSSTELTELUGPUGPUGPUGPUGPUGPTELTELTELTELUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELTELUGPUGPUGPUGPUGP 8,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD28,022 SFRESTAURANT2,616 SFRETAILSTAIR 1STAIR 5 3,529 SFLEASING/LOBBY2,840 SFRETAILSTAIR 251 SFL ROOMELEVATOR 2ELEVATOR 1ELEVATOR 32,644 SFRETAIL5,353 SFRETAIL1,893 SFTRASH2,622 SFRETAIL1,531 SFFITNESSSTAIR 5 STAIR 2UNIT B2UNIT AU1UNIT B21,000 SFPUMP ROOMUNIT AU1UNIT B2LOADINGSTAIR 3RESIDENTIALSTORAGETRASH313 SFBOHBOHUNIT A1UNIT A1UNIT B1UNIT B1STAIR 4UNIT A5UNIT S1BOHBOHUNIT A5UNIT AD2UNIT AD2GENTR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WTTTTTTTSOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)EXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINEXISTINGBUILDING TOREMAINRETAILLEASING/LOBBYPARKINGDECK ENTRYLOADINGRETAIL/EDEERETAILFUTURE 36' CATSRAIL ROWPARCEL NOT PARTOF PROJECT(PARCEL ID 07318310)14' SETBACK 14' SETBACKEXISTINGPARKING TOREMAINRETAILRETAILRETAILFITNESSFUTURE 36' CATSRAIL ROWZONE OF SUSPENDED SLABPAVEMENT, INSTALL PERSTANDARD CLDS DETAILSZONE OF SUSPENDED SLABPAVEMENT, INSTALL PERSTANDARD CLDS DETAILSZONE OF SUSPENDED SLABPAVEMENT, INSTALL PERSTANDARD CLDS DETAILSZONE OF SUSPENDED SLABPAVEMENT, INSTALL PERSTANDARD CLDS DETAILSMIN. 15'-0"EXISTING POLE TO REMAINEXISTING POLE TO REMAINEXISTING POLE TO REMAINEXISTING POLE TOREMAINZONE OF SUSPENDEDSLAB PAVEMENT ORSILVA CELL SYSTEM40' PARKINGCOVERAGE TYP.ZONE OF SUSPENDED SLABPAVEMENT, INSTALL PERSTANDARD CLDS DETAILSTREESCODEQTYBOTANICAL NAMECOMMON NAMEMIN. CONT.MIN. CAL.MIN. HT.REMARKSLPW17LARGE MATURING TREEINTERNAL TREEB & B3" MIN.8-10CSPECIES TO BE DETERMINED*SPECIES TO BE FROM THEAPPROVED CHARLOTTE TREE LIST.SWD4SMALL MATURING TREESTREET TREE A (CEDAR STREET)B & B3" MIN.8-10CSPECIES TO BE DETERMINED*SPECIES TO BE FROM THEAPPROVEDCHARLOTTE TREE LIST.SWE9SMALL MATURING TREESTREET TREE B (STADIUM VIEW DR)B & B3" MIN.8-10CSPECIES TO BE DETERMINED*SPECIES TO BE FROM THEAPPROVEDCHARLOTTE TREE LIST.GROUND COVERSCODEQTYBOTANICAL NAMECOMMON NAMEMIN. CONT.SPACINGMIN. HT.REMARKSAF16,380ACCENT SHRUBS/GROUNDCOVERVARIESVARIESVARIES- SOIL & BED PREPARATION /FERTILIZER- 3IN MULCH DEPTH- 10% GROUNDCOVER @ 12IN O.C.- 30% SMALL SHRUBS @ 2FT O.C.- 30% MEDIUM SHRUBS @ 3FT O.C.- 30% LARGE SHRUBS @ 5FT O.C.- FULLY IRRIGATEDPLANT SCHEDULEMODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147REQUIRED PLANTING PLANN/AC8-0011/11/2022 10:20 AM KIERA MURUVE P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_PLNT.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658THESE DOCUMENTS ARE FOR DESIGNREVIEW ONLY AND NOT INTENDED FORCONSTRUCTION, BIDDING, OR PERMITPURPOSE. THEY ARE PREPARED BY, ORUNDER THE SUPERVISION OF:ENGINEERDATEPRELIMINARY-FOR REVIEW ONLY-XXXXX XXXXXXXX####10/21/22REG. #NOT FORCONSTRUCTIONSCHEMATIC DESIGN11.11.20221 1" = 20'4020010GENERAL PLANTING NOTES1.AN UNDISTURBED TREE ANALYSIS WILL BE CONDUCTED IN THE FIELD WITH URBANFORESTRY PRIOR TO SITE CONSTRUCTION COMMENCEMENT.2.TREES WITHIN THE STREET RIGHT-OF-WAY ARE PROTECTED BY LAW. A PERMIT ISREQUIRED FROM THE CITY ARBORIST AT (704) 336-5753 PRIOR TO THE REMOVAL OF ANYRIGHT-OF-WAY TREES.3.ALL LARGE MATURING TREES IN R/W MUST BE AT LEAST 30' APART.4.ALL LARGE MATURING TREES OUTSIDE OF R/W MUST BE AT LEAST 25' APART.5.TREES NEED TO BE AT LEAST 10' FROM BUILDINGS AND UTILITIES.6.PLANTING SHOWN IS FOR MINIMUM REQUIRED PLANTING PER THE ORDINANCE FORPERMITTING ONLY. REFER TO FINAL PLANTING PLANS FOR ADDITIONAL SCHEDULE,QUANTITIES, DETAIL, AND PLANTING DESIGN.CHARLOTTE URBAN FORESTRY - TREE PLANTING AND PRESERVATION REQUIREMENTS(UPDATED 1/26/2022)INSPECTOR CONTACT INFO: HTTPS://CHARLOTTEEXPLORER/ CLICK PLANNING LAYER > LANDDEVELOPMENT – URBAN FORESTRY INSPECTORSPLANT MATERIAL1.MINIMUM TREE SIZE AT PLANTING IS 2” CALIPER AND 8’ TALL FOR SINGLE-STEM TREES.ALL MULTI-STEM PLANTS MUST BE TREE FORM, MAXIMUM 3 TO 5 TRUNKS, AND MINIMUM10’ TALL. WHERE 3” SINGLE-STEM CALIPER TREES ARE SPECIFIED/REQUIRED THEMINIMUM HEIGHT SHALL BE 10’ TALL, IF MULTI-STEM TREES ARE SPECIFIED THEN THEYSHALL BE A MINIMUM OF 12’ TALL.2.ALL NEW TREES MUST HAVE STRAIGHT TRUNKS WITH STRONG CENTRAL LEADERSINTACT TO THE TOP OF THE CROWN UNLESS MULTI-STEM TREES ARE SPECIFIED. ALLREQUIRED TREES SHALL BE TYPICAL OF THEIR SPECIES AND VARIETY, HAVE NORMALGROWTH HABITS, HAVE WELL-DEVELOPED BRANCHES, BE VIGOROUS AND HAVEFIBROUS ROOT SYSTEMS. TREES WITH MAJOR GIRDLING ROOTS WILL NOT BEACCEPTED. TREES WITH CODOMINANT BRANCHING WILL NOT BE ACCEPTED. TREESTHAT HAVE BEEN SHEARED, TOPPED OR CUT BACK TO MULTIPLY THE BRANCHINGSTRUCTURE WILL NOT BE ACCEPTED. TREES SHALL BE FREE OF ABRASIONS, DAMAGE,DISEASE, PESTS AND CRACKS. ALL PRUNING CUTS GREATER THAN ½ INCH DIAMETERSHALL HAVE CALLUS TISSUE FORMED PRIOR TO PLANTING. NO PRUNING CUT ON THETRUNK SHALL BE MORE THAN ONE-HALF THE DIAMETER OF THE CENTRAL LEADER ATTHE HEIGHT WHERE THE CUT WAS MADE. ROOT FLARES SHALL BE LOCATED AT GRADE.TREES WITH MORE THAN 2” OF SOIL COVERING THE ROOT BALL/FLARE FROM WILL NOTBE ACCEPTED (CLDS.40.09).3.SIZE OF REQUIRED PLANTS, SPREAD OF ROOTS AND SIZE OF BALLS SHALL BE INACCORDANCE WITH ANSI Z60.1 (LATEST EDITION) AS PUBLISHED BY THE AMERICANNURSERY & LANDSCAPE ASSOCIATION, EXCEPT WHERE SPECIFIED/AUTHORIZED BYURBAN FORESTRY. ALL REQUIRED TREES OF A PARTICULAR SPECIES AND VARIETYSHALL BE UNIFORM IN SIZE AND CONFIGURATION.4.PERIMETER TREES IN URBAN ZONES SHALL BE 3” IN CALIPER AND BE FREE OFBRANCHES UP TO 6’ FROM THE TOP OF ROOT CROWN (BALL).5.A MINIMUM OF 50% OF NEW TREES MUST BE NATIVE SPECIES, AND SITES WITH MORETHAN 20 TREES REQUIRED WILL HAVE TO INSTALL MULTIPLE (3 OR MORE) SPECIESPURSUANT TO THE TREE ORDINANCE GUIDELINES.6.75% OF REQUIRED TREES MUST BE LARGE MATURE SPECIES EXCEPT IN SITUATIONSWITH OVERHEAD POWER LINE CONFLICTS.PLANTING REQUIREMENTS7.SEE CLDS 40.01 & 40.09 (ON PLAN) FOR DETAILED TREE PLANTING REQUIREMENTS.8.PLASTIC HOSE PARTS WILL NOT BE ACCEPTED FOR TREE STAKING. SEE CLDS 40.01 FORAPPROVED STAKING METHOD/MATERIALS.9.ALL STRAPPING, AND TOP 1/3 OF WIRE BASKET AND BURLAP MUST BE CUT AWAY ANDREMOVED FROM ROOT BALL WHEN PLANTING.10.FOR NEW PLANTING AREAS, REMOVE ALL PAVEMENT, GRAVEL SUB-BASE ANDCONSTRUCTION DEBRIS; REMOVE COMPACTED SOIL AND ADD 18" NEW TOPSOIL, OR TILLAND AMEND THE TOP 18" OF EXISTING SOIL TO MEET TOPSOIL/PLANTING MIXSTANDARDS FOR TREES (WITHIN ENTIRE MINIMUM AREA OF 274 SQUARE FEET).11.TREES PLANTED ON PUBLIC STREET RIGHT-OF-WAY REQUIRE APPROVAL FROM URBANFORESTRY PRIOR TO INSTALLATION.12.REVIEW SOIL REQUIREMENTS IN THE TREE ORDINANCE GUIDELINES.UTILITY ISSUES13.IF UTILITY IS TO BE INSTALLED IN/NEAR ANY REQUIRED TREE(S) OR TREE SAVE AREA(S),CALL URBAN FORESTRY PRIOR TO UTILITY INSTALLATION.14.LARGE MATURING TREES MAY NOT BE PLANTED WITHIN 25’ OF OVERHEAD POWERDISTRIBUTION OR TRANSMISSION LINES.15.IF TREES CONFLICT WITH ANY UTILITIES OR SIGNS; CALL URBAN FORESTER TO RESOLVEBEFORE PLANTING.16.ADJUST TREE PLANTING LOCATIONS TO AVOID EXISTING UNDERGROUND UTILITIES.PLANT 15’ FROM ALL UNDERGROUND UTILITIES.17.NO LIGHT POLES, UTILITIES OR TRANSFORMERS CAN BE INSTALLED IN TREE ISLANDS.18.COMMERCIAL SCALE LIGHTING (> 15’ IN HEIGHT) MUST BE A MINIMUM DISTANCE OF 30’FROM A TREE. PEDESTRIAN SCALE LIGHTING (≤ 15’ IN MUST BE A MINIMUM DISTANCE OF15’ FROM A TREE. SHOW SITE LIGHTING ON LANDSCAPE PLAN.TREE SAVE AND PRESERVATION19.TREE PROTECTION MUST BE INSTALLED AND VERIFIED BY URBAN FORESTRY PRIOR TOSTARTING ANY CONSTRUCTION ACTIVITY.20.SHOW TREE PROTECTION AND TREES SAVE AREAS ON DEMOLITION, EROSION CONTROL,GRADING AND LANDSCAPE PLAN SHEETS.21.COMMERCIAL TREE SAVE AREAS MUST BE RECORDED ON A FINAL PLAT WITH THEMECKLENBURG COUNTY REGISTER OF DEEDS BEFORE URBAN FORESTRY HOLDS CAN BERELEASED. A 10’ NO BUILD ZONE AROUND TREE SAVE AREAS MUST BE REFERENCED ONTHE PLAT.22.TREE SAVE AREAS SHALL BE FREE OF INVASIVE PLANT SPECIES. IF AN AREA PROPOSEDFOR TREE SAVE CONTAINS INVASIVE PLANT SPECIES AT TIME OF PROPOSAL, SUCHINVASIVE PLANT SPECIES SHALL BE REMOVED PRIOR TO FINAL CO.23.THE AREA OF ANY EASEMENTS (WATER, SEWER, UTILITY, ETC.) CAN NOT BE COUNTEDTOWARD THE TREE SAVE REQUIREMENT.24.ANY ACTIVITY IN TREE SAVE AREAS MUST BE ACCOMPLISHED WITHOUT MECHANIZEDEQUIPMENT.25.NO STRUCTURE WILL BE ALLOWED WITHIN 10’ OF TREE SAVE AREAS UNLESS APPROVEDBY URBAN FORESTRY.26.ALL TREES ON PUBLIC STREET RIGHT-OF-WAY/PROPERTY ARE PROTECTED ANDREMOVAL MUST BE PERMITTED BY URBAN FORESTRY.27.CONTACT URBAN FORESTRY PRIOR TO ANY CRANE SET-UP, MACHINERY OPERATION ORTEMPORARY BUILDING ERECTION THAT MAY IMPACT PROTECTED TREES, TREE SAVEAREAS, INCLUDING CITY TREES IN PUBLIC RIGHT-OF-WAY. IMPACTS MAY INCLUDE BUTARE NOT LIMITED ENCROACHING IN TREE DRIP-LINES, EXCAVATION, SOIL COMPACTION,TREE TRIMMING, ERECTING AND DISMANTLING OF CONSTRUCTION CRANES.GENERAL28.SUBMIT REQUIRED CO/HOLD RELEASE FORM ATHTTPS://CHARLOTTENC.GOV/DEVELOPMENTCENTER FOR AN INSPECTION OF TREEPROTECTION/PLANTING AREAS, A MINIMUM OF 3 DAYS BEFORE THE CO/HOLD RELEASE ISNEEDED.29.VISIT CITY OF CHARLOTTE’S CLT DEVELOPMENT CENTER WEBSITE FOR ADDITIONALINFORMATION AND URBAN FORESTRY REQUIREMENTS:HTTPS://CHARLOTTENC.GOV/DEVELOPMENTCENTER THEN CLICK TREES.30.ALL TREE SAVE PAYMENT-IN-LIEU, PERIMETER TREE PAYMENT IN LIEU, AND CITY TREEMITIGATION PAYMENTS (CHECKS) MUST BE SUBMITTED TO:ATTN: URBAN FORESTRY SUPERVISORCLT DEVELOPMENT CENTER600 E. FOURTH ST. (1ST FLOOR)CHARLOTTE, NC 28202CEDAR STREET:TREES REQUIRED = 11 TREES (365'/35' = 10.4)± 365 LF TOTALTREES PROVIDED = 4 TREES(SMALL MATURING)7 TREES PAY IN LIEU(7 x $6,500 = $45,500)STADIUM VIEW DR:TREES REQUIRED = 15 TREES (522/35' = 14.9)± 522 LF TOTALTREES PROVIDED = 9 TREES(SMALL MATURING)6 TREES PAY IN LIEU(6 x $6,500 = $39,000)TOTAL PAY IN LIEU:$84,500*TOTAL PAY IN LIEU MAY BE REDUCED IF FRONTAGE LIMITS(CEDAR ST. EXISTING BUILDINGS + CATS DEDICATED ROWALONG STADIUM VIEW DR.) CAN BE REDUCEDREQUIREMENT: 50% OF NEW TREESMUST BE NATIVE SPECIES.XX NATIVE TREES REQUIRED29 TOTAL NEW TREES PROVIDED29 NATIVE TREES PROVIDED (100%)CONTINUOUS PLANTING STRIP; AVG WIDTH 8'; 1 LARGE TREE PER 40' OR 1 SMALLTREE PER 30' PER STREET FRONTAGE, 3” CAL. MIN.NATIVE SPECIES REQUIREMENT (SEC. 21-96 C)PERIMETER PLANTING REQUIREMENT (SEC. 21-96 F)1 LARGE MATURING SHADE TREE PER10,000 SF IMPERVIOUS AREA17 TREES REQUIRED17 TREES PROVIDED±XXX SF PLANTING AREA REQUIRED±XXX SF PLANTING AREA PROVIDEDPLANTING AREA EQUAL TO 10% OFTOTAL IMPERVIOUS SURFACE AREATOTAL IMPERVIOUS AREA: ±167,716 SFINTERNAL PLANTING REQUIREMENT (SEC. 21-96 G)INTERNAL TREES REQUIREDTREE SAVE AREA (TSA) REQUIREMENTS- EXEMPT FROM TREE SAVE. *SITE LOCATED WITHIN A TRANSIT CENTER. F. D. C. GEN F. D. C.F. D. C. SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)PROPER TY LINE SETBACK FOR LIGHT RAIL FUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)FUTURE LIGHT RAIL EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING NEW TRANSFORMER TO SERVE EXISTING BUILDINGS COURTYARD A COURTYARD BCOURTYARD C BUILDING 01 3 HOURS FIRE WALL BUILDING 02 ROOF ACCESS 100' - 0"140' - 0"140' - 0"71' - 8" TRANSFORMER #T4 - REFER TO ELECTRICAL TRANSFORMER #T5 - REFER TO ELECTRICAL TRANSFORMER #T1 - REFER TO ELECTRICAL TRANSFORMER #T2 - REFER TO ELECTRICAL TRANSFORMER #T3 - REFER TO ELECTRICAL PROPOSED ADDRESS:619 SOUTH CEDAR ST. CHARLOTTE, NC ZONING: SITE AREA: BUILDING SETBACKS SIDE YARD: REAR YARD: PROPOSED OVERALL USE: MULTI-FAMILY:374 UNITS REQUIRED PARKING: RESIDENTIAL: MIN. REQUIRED:XXX PARKING PROVIDED:XXX MAX. ALLOWED:XXX NON-RESIDENTIAL: MIN. REQUIRED:XXX PARKING PROVIDED:XXX MAX. ALLOWED:XXX PARKING PROVIDED: STANDARD:XXX COMPACT:XXX HANDICAP:XXX ELECTRIC:XXX ELECTRIC READY:XXX TOTAL:599 SIZES: STANDARD:XX X XX COMPACT:XX X XX BICYCLE PARKING: RESIDENTIAL: MIN. REQUIRED:XXX PARKING PROVIDED:XXX NON-RESIDENTIAL: MIN. REQUIRED:XXX PARKING PROVIDED:XXX SITE DATA LEGEND C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:02 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.00 2247601 SITE PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1" = 20'-0"1 LEVEL 1 - SITE PLAN DATE DESCRIPTION REV TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING 2 A06.01 7,968 SF RETAIL 2,337 SF RETAIL SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)SETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)C D E F G H J K L M N P Q R 4 U 7 6 5 1 2 1 A06.01 1 A06.01 3 A06.02 3 A06.02 2 A06.02 2 A06.02 3 A06.01 30' - 0"63' - 0 1/2"20.45° SSTAIR 15,208 SF LEASING/LOBBY 533 SF TRASH 2,548 SF RETAIL STAIR 4 1,319 SF MAIL ROOM 25' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"28' - 3"16' - 9" 9 10 11 13 14 16 17 421' - 0"15' - 6"24' - 0"24' - 6"24' - 6"24' - 6"30' - 1"24' - 5"24' - 0"27' - 0"25' - 0"18' - 6 1/2"14' - 6"276' - 6 1/2"ELEVATOR 2 ELEVATOR 3 ELEVATOR 1 8 3 T B OV XY 15 12 1 A06.02 2,606 SF RETAIL 5,533 SF RESTAURANT 1,445 SF TRASH 2,722 SF RETAIL 4 A06.02 6' - 0"39 SF MECH CLOSET 1 A06.10 11' - 6"11' - 6"11' - 6"11' - 6"13' - 0"11' - 6"11' - 6"11' - 6"11' - 6"13' - 0"11' - 6"11' - 6"11' - 6"11' - 6"78 SF MDF ROOM 25 SF STANDPIPE ROOM STAIR 5 7' - 6" LINE OF BUILDING ABOVE FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:03 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.01 2247601 LEVEL 1 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 1 OVERALL FLOOR PLAN UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV UP 2 A06.01 2 A06.01 K L M N P Q R 4 U 7 6 5 1 2 3 A06.02 3 A06.02 3 A06.01 SREFER TO: 1 / A02.01B533 SF TRASH ELEVATOR 1 2,548 SF RETAIL 7,968 SF RETAIL STAIR 1 8 3 T MECH SHAFT ABOVE FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:04 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.01A 2247601 LEVEL 1 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 1 - ENLARGED FLOOR PLAN - AREA A UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 2 A06.01 C D E F G H J 4 7 6 5 1 2 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01REFER TO: 1 / A02.01AREFER TO: 1 / A02.01C SERVICE CORRIDOR 1,319 SF MAIL ROOM ELEVATOR 2 ELEVATOR 3 5,208 SF LEASING/LOBBY 2,548 SF RETAIL 8 3 B OV XY 39 SF MECH CLOSET 1 A06.10 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:09 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.01B 2247601 LEVEL 1 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 1 - ENLARGED FLOOR PLAN - AREA B UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV C D E 1 A06.01 1 A06.01 A05.024 2,337 SF RETAIL 9 10 11 13 14 16 17 8 B OV XY 15 12 1 A06.02 1 A06.02 4 A06.02 4 A06.02 1 A06.10 RESIDENTIAL RETAIL MECH SHAFT ABOVE 2,722 SF RETAIL 2,606 SF RETAIL FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:15 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.01C 2247601 LEVEL 1 - ENLARGED FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 1 - ENLARGED FLOOR PLAN - AREA C UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV UP 2 A06.01 SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)SETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)C D E F G H J K L M N P Q R STAIR 14 U 7 6 5 1 2 STAIR 3 1 A06.01 3 A06.02 2 A06.02 3 A06.01 A05.01 S STAIR 4 2 5.7% 9 10 11 13 14 16 17 ELEVATOR 2 ELEVATOR 3 ELEVATOR 1 CIRCULATION 8 3 T B OV XY 15 12 1 A06.02 25' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"28' - 3"16' - 9" 421' - 0"15' - 6"24' - 0"24' - 6"24' - 6"24' - 6"30' - 1"24' - 5"24' - 0"27' - 0"25' - 0"18' - 6 1/2"14' - 6"30' - 0"15' - 0"15' - 0"30' - 0"366' - 6 1/2"50,619 SF GARAGE 4 A06.02 11' - 0"2' - 6"23' - 4 113/128"170 SF MECH INTAKE SHAFT 263 SF MECH EXHAUST SHAFT 1 A06.10 214 SF BOH 18' - 0"4 ' - 4"10 ' - 0"3' - 4 "10 ' - 0"4' - 0"17' - 6"4 ' - 0"17' - 0" LINE OF BUILDING ABOVE FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:17 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.02 2247601 LEVEL 2 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 2 OVERALL FLOOR PLAN UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV UP 2 A06.01 2 A06.01 K L M N P Q R 4 U 7 6 5 1 2 3 A06.02 3 A06.02 3 A06.01 S A05.02 3 REFER TO: 1 / A02.02BELEVATOR 1 CIRCULATION STAIR 1 8 3 T 263 SF MECH EXHAUST SHAFT 50,619 SF GARAGE FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:18 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.02A 2247601 LEVEL 2 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 2 - ENLARGED FLOOR PLAN - AREA A UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 2 A06.01 C D E F G H J 4 7 6 5 1 2 1 A06.01 1 A06.01 2 A06.02 3 A06.01 3 A06.01 STAIR 3 REFER TO: 1 / A02.02C ELEVATOR 2 ELEVATOR 3CIRCULATION 8 3 B OV XY 170 SF MECH INTAKE SHAFT 1 A06.10 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:18 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.02B 2247601 LEVEL 2 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 2 - ENLARGED FLOOR PLAN - AREA B UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV C D E 1 A06.01 1 A06.01 A05.024 REFER TO: 1 / A02.02B 9 10 11 13 14 16 17 8 B OV XY 15 12 1 A06.02 1 A06.02 4 A06.02 4 A06.02 1 A06.10 WASTE RECYCLE FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:19 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.02C 2247601 LEVEL 2 - ENLARGED FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 2 - ENLARGED FLOOR PLAN - AREA C UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV DN UP 60" 2 A06.01 SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)SETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)C D E F G H J K L M N P Q R 614 SF ELEC ROOM 4 U 7 6 5 1 2STAIR 1STAIR 3 1 A06.01 3 A06.02 2 A06.02 3 A06.01 A05.01 S JANSTAIR 4 UNIT AU1 2 UNIT A4 RESIDENTIAL STORAGE 5.7%5.7% 873 SF PUMP ROOM 862 SF ELEC ROOM 9 10 11 13 14 16 17 ELEVATOR 3 ELEVATOR 2 ELEVATOR 1 TRASH 8 3 T B OV XY 15 12 UNIT AU1 1 A06.02 25' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"28' - 3"16' - 9" 421' - 0"15' - 6"24' - 0"24' - 6"24' - 6"24' - 6"30' - 1"24' - 5"24' - 0"27' - 0"25' - 0"18' - 6 1/2"14' - 6"30' - 0"15' - 0"15' - 0"30' - 0"366' - 6 1/2"UNIT A6 UNIT A6 UNIT A6 25' - 0"34' - 0"17' - 6" 125 SF FIRE COMMAND 413 SF PET SPA RESIDENTIAL STORAGE RESIDENTIAL STORAGE 10 UNITS13 UNITS13 UNITS UNIT A6 UNIT S2 UNIT S3 UNIT AD2 UNIT BA1UNIT BA1 4 A06.02 170 SF MECH INTAKE SHAFT 263 SF MECH EXHAUST SHAFT MECH SHAFT MECH SHAFT MECH EXHAUST SHAFT 1 A06.10 214 SF BOH UNIT B3UNIT B3 EMERGENCY PANEL ROOM MECH SHAFT TELECOM BOH TELECOM MECH EXHAUST SHAFT RAMP STARTSSLOPE RAMP 1-2% TOWARD CENTER FOR DRAIANGEUNIT A1 UNIT AD2 UNIT AD2.1 UNIT B2 UNIT B2 UNIT B2 UNIT A1 UNIT BA1 UNIT BA1 UNIT C1 UNIT A8 UNIT B2 UNIT A1 LINE OF BUILDING ABOVE UNIT A1 1" / 12"FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:22 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.03 2247601 LEVEL 3 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 3 OVERALL FLOOR PLAN UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV UP 2 A06.01 K L M N P Q R 4 U 7 6 5 1 2 3 A06.02 3 A06.02 3 A06.01 614 SF ELEC ROOM STAIR 1 S A05.02 3 REFER TO: 1 / A02.03BELEVATOR 1 TRASH GARAGE UNIT A4 8 3 T UNIT A6 192 SF TELECOM 413 SF PET SPA UNIT S2 UNIT S3 614 SF ELEC ROOM 263 SF MECH EXHAUST SHAFT MECH SHAFT MECH EXHAUST SHAFT RAMP STARTSSLOPE RAMP 1-2% TOWARD CENTER FOR DRAIANGEUNIT A1 UNIT A1 UNIT AD2 UNIT AD2.1 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:29 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.03A 2247601 LEVEL 3 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 3 - ENLARGED FLOOR PLAN - AREA A UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 2 A06.01 C D E F G H J 4 7 6 5 1 2 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 STAIR 3 REFER TO: 1 / A02.03AREFER TO: 1 / A02.03C 873 SF PUMP ROOM STAIR 4 JAN ELEVATOR 3 ELEVATOR 2 RESIDENTIAL STORAGE GARAGE 862 SF ELEC ROOM 8 3 B OV XY 125 SF FIRE COMMAND UNIT A6 724 SF UNIT A6 170 SF MECH INTAKE SHAFT MECH SHAFT 1 A06.10 UNIT B3UNIT B3 1" / 12"7' - 0"214 SF BOH EMERGENCY PANEL ROOM TELECOM FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:35 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.03B 2247601 LEVEL 3 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 3 - ENLARGED FLOOR PLAN - AREA B UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV DN C D E 1 A06.01 1 A06.01 A05.024 REFER TO: 1 / A02.03B 9 10 11 13 14 16 17 669 SF UNIT AU1 8 B OV XY 15 12 660 SF UNIT AU1 1 A06.02 1 A06.02 4 A06.02 4 A06.02 1 A06.10 MECH EXHAUST SHAFT 729 SF UNIT A6 1,001 SF UNIT BA1 681 SF UNIT A1 1,005 SF UNIT BA1 680 SF UNIT A1 1,005 SF UNIT BA1 1,010 SF UNIT B2 888 SF UNIT AD2 1,073 SF UNIT B2 1,025 SF UNIT B2 1,139 SF UNIT B2 MECH SHAFT TELECOM 845 SF UNIT A8 WASTE RECYCLE 1,394 SF UNIT C1 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:10:44 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.03C 2247601 LEVEL 3 - ENLARGED FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 3 - ENLARGED FLOOR PLAN - AREA C UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)SETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)C D E F G H J K L M N P Q R 4 U 7 6 5 1 2STAIR 1STAIR 3 1 A06.01 3 A06.02 2 A06.02 3 A06.01 A05.01 S 49,343 SF GARAGE LOADING LOADING ENTRANCEAND EXITSTAIR 4 2 UNIT A4 5.7%5.7% 8 3 T B 1 A06.02 25' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"28' - 3"16' - 9" 421' - 0"25' - 0"18' - 6 1/2"14' - 6"30' - 0"15' - 0"15' - 0"30' - 0"UNIT A6 UNIT A6 UNIT BA1UNIT BA1 4 A06.02 158 SF MECH INTAKE SHAFT 263 SF MECH EXHAUST SHAFT MECH SHAFT MECH EXHAUST SHAFT 1 A06.10 JAN 723 SF MAINTENENCE AND ENGINEERING 180 SF OFFICE 341 SF MAINTENENCE STORAGE 755 SF GAME ROOM 163 SF MOVIE ROOM UNIT A1 UNIT A1 UNIT AD2 UNIT AD2.1UNIT S3UNIT A6 UNIT A6 UNIT B2 UNIT B2 UNIT AU1 UNIT AU1 UNIT B2 UNIT AD2 UNIT A8 UNIT B2 UNIT A1 UNIT BA1 UNIT A1 UNIT BA1 UNIT C1 UNIT B3UNIT B3 MECH SHAFT ELEC ROOM TRASH TELECOM MECH SHAFT MECH EXHAUST SHAFT RAMP STARTSSLOPE RAMP 1-2% TOWARD CENTER FOR DRAIANGEUNIT S2 455 SF GOLF SIMULATION ROOM RESIDENTIAL STORAGE RESIDENTIAL STORAGE 13 UNITS13 UNITS LINE OF BUILDING ABOVE1" / 12"FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:42:41 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.04 2247601 LEVEL 4 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 4 OVERALL FLOOR PLAN UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 2 A06.01 K L M N P Q R 4 U 7 6 5 1 2 3 A06.02 3 A06.02 3 A06.01 3 A06.01 STAIR 1 S A05.02 3 REFER TO: 1 / A02.04BELEVATOR 1 TRASH 49,343 SF GARAGE UNIT A4 8 3 T UNIT S3 263 SF MECH EXHAUST SHAFT DUCKPIN EQUIPMENT: 9'-2" X 39'-10" POOL TABLE: 7'-0" X 4'-0" CLEARANCE: 17'-0" X 11'-0"755 SF GAME ROOM 455 SF GOLF SIMULATION ROOM 10'-0" X 16'-0"10'-0" X 16'-0" 131 SF TELECOM RAMP STARTSSLOPE RAMP 1-2% TOWARD CENTER FOR DRAIANGEUNIT A6 UNIT A1 UNIT A1 UNIT AD2 UNIT AD2.1 UNIT S2 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:42:49 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.04A 2247601 LEVEL 4 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 4 - ENLARGED FLOOR PLAN - AREA A UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 2 A06.01 C D E F G H J 4 7 6 5 1 2 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.01 REFER TO: 1 / A02.04C STAIR 3STAIR 4 JAN ELEVATOR 3 ELEVATOR 2 RESIDENTIAL STORAGE 1,865 SF LOADING 8 3 B 158 SF MECH INTAKE SHAFT MECH SHAFT 1 A06.10 UNIT B3UNIT B3UNIT A6 724 SF UNIT A6 341 SF MAINTENENCE STORAGE1" / 12"7' - 0"FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:42:56 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.04B 2247601 LEVEL 4 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 4 - ENLARGED FLOOR PLAN - AREA B UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV C D 1 A06.01 1 A06.01 A05.024 REFER TO: 1 / A02.04B 8 B 1 A06.02 1 A06.02 4 A06.02 4 A06.02 1 A06.10 MECH EXHAUST SHAFT 728 SF UNIT A6 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1 1,016 SF UNIT B2 892 SF UNIT AD2 1,077 SF UNIT B2 664 SF UNIT AU1 673 SF UNIT AU1 1,028 SF UNIT B2 1,145 SF UNIT B2 43 SF ELEC ROOM 849 SF UNIT A8 WASTE RECYCLE 1,405 SF UNIT C1 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:05 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.04C 2247601 LEVEL 4 - ENLARGED FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 4 - ENLARGED FLOOR PLAN - AREA C UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)SETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)2 A06.01 C D E F G H J K L M N P Q R 4 U 7 6 5 1 2STAIR 1STAIR 3 1 A06.01 3 A06.02 2 A06.02 3 A06.01 A05.01 S 2 STAIR 4 5.7% 399 SF POOL EQUIP AND STORAGE ROOM TRASH 8 3 T B 1 A06.02 25' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"27' - 0"28' - 3"16' - 9" 421' - 0"25' - 0"18' - 6 1/2"14' - 6"30' - 0"15' - 0"15' - 0"30' - 0"PARKING DECK ENTRANCE AND EXITSHORT TERM BIKE STORAGE TELECOM LONG TERM BIKE STORAGE 4 A06.02 158 SF MECH INTAKE SHAFT MECH SHAFT MECH EXHAUST SHAFT 1 A06.10 JAN 26' - 6" UNIT A4 UNIT AD2.1UNIT AD2 UNIT A1UNIT A1UNIT S3-AUNIT A6UNIT A6UNIT A6 UNIT A6 UNIT BA1-A UNIT A1 UNIT BA1 UNIT A1 UNIT BA1-A UNIT C1 UNIT B2 UNIT A8 UNIT AD2 UNIT B2 UNIT B2 UNIT B2 UNIT AU1 UNIT AU1 UNIT B2 MECH EXHAUST SHAFT UNIT B3 UNIT B3 MECH SHAFT TELECOM ELEC ROOMELEC ROOM MECH SHAFT MECH EXHAUST SHAFT 2' - 0"4' - 9"10' - 0"2' - 0"10' - 0"2' - 10" WOMENSMENS UNIT S2 RAMP STARTSSLOPE RAMP 1-2% TOWARD CENTER FOR DRAIANGEBOH 18' - 6"23' - 0"18' - 6"FUTURE TENANT FUTURE TENANT 15 MINUTE PARKING 15 MINUTE PARKING 15 MINUTE PARKING LINE OF BUILDING ABOVE1" / 12"FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:14 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.05 2247601 LEVEL 5 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 5 OVERALL FLOOR PLAN UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 2 A06.01 K L M N P Q R 4 U 7 6 5 1 2 3 A06.02 3 A06.02 3 A06.01 3 A06.01 STAIR 1 S A05.02 3 REFER TO: 1 / A02.05B8 3 T 730 SF UNIT A6 537 SF UNIT S3-A 753 SF UNIT A1 743 SF UNIT A1 849 SF UNIT AD2 916 SF UNIT AD2.1 994 SF UNIT A4 617 SF UNIT S2 STAIR 2 263 SF MECH EXHAUST SHAFT 131 SF ELEC ROOM 67 SF ELEVATOR 1 139 SF ELEV LOBBY 37 SF TRASH 209 SF WOMENS 137 SF MENS JAN.RAMP STARTSSLOPE RAMP 1-2% TOWARD CENTER FOR DRAIANGEFLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:23 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.05A 2247601 LEVEL 5 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 5 - ENLARGED FLOOR PLAN - AREA A UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 2 A06.01 C D E F G H J 4 7 6 5 1 2 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.01STAIR 3REFER TO: 1 / A02.05C REFER TO: 1 / A02.05A 8 3 B 158 SF MECH INTAKE SHAFT MECH SHAFT 1 A06.10 5' - 1"10' - 1"25 % OPENINGS ALLOWED PER NC BUILDING CODE SECTION 70 5.8 15 % OPENING S ALLOWED PER NC BUILDING CODE SECTION 705.8 724 SF UNIT A6 730 SF UNIT A6 1,026 SF UNIT B3 1,026 SF UNIT B3 49,139 SF GARAGE 531 SF ELEV LOBBY 746 SF LONG TERM BIKE STORAGE 36 SF TELECOM 399 SF POOL EQUIP AND STORAGE ROOM 137 SF MENS JAN. 104 SF ELEC ROOM 724 SF UNIT A6 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:30 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.05B 2247601 LEVEL 5 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 5 - ENLARGED FLOOR PLAN - AREA B UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV C D 1 A06.01 1 A06.01 A05.024 REFER TO: 1 / A02.05A 8 B 1 A06.02 1 A06.02 4 A06.02 4 A06.02 1 A06.10 WASTE RECYCLE MECH EXHAUST SHAFT 729 SF UNIT A6 1,010 SF UNIT BA1-A 688 SF UNIT A1 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1-A 1,016 SF UNIT B2 892 SF UNIT AD2 1,077 SF UNIT B2 664 SF UNIT AU1 672 SF UNIT AU1 1,028 SF UNIT B2 1,146 SF UNIT B2 1,101 SF UNIT B2 26 SF MECH SHAFT 43 SF BOH 1,404 SF UNIT C1 849 SF UNIT A8 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:39 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.05C 2247601 LEVEL 5 - ENLARGED FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 5 - ENLARGED FLOOR PLAN - AREA C UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% TOTAL PARKING COUNT BY LEVEL SPACE TYPE WIDTH LENGTH QUANTITY ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 159 LEVEL 2 167 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 152 LEVEL 3 160 ADA 8' - 6" 18' - 0" 3 C 8' - 0" 16' - 0" 5 STND 8' - 6" 18' - 6" 147 LEVEL 4 155 ADA 8' - 6" 18' - 0" 2 C 8' - 0" 16' - 0" 6 STND 8' - 6" 18' - 6" 107 VAN 9' - 0" 18' - 6" 2 LEVEL 5 117 Grand total 599 PARKING RATIO: PARKING COUNT -599 REPLACEMENT SPACES -46 COMMERCIAL SPACES -47 RESIDENTIAL PARKING COUNT -506 UNIT COUNT -374 PARKING PER UNIT -1.35 BICYCLE PARKING: UNIT COUNT -374 TOTAL BICYCLE PARKING -75 LONG TERM BICYCLE PARKNG -60 SHORT TERM BICYCLE PARKING -15 DATE DESCRIPTION REV 2 A06.01 2 A06.01 SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)SETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)STAIR 3 1 A06.01 1 A06.01 3 A06.02 3 A06.02 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.03 5 4 7 6 A05.03 2 13 A05.03 10 9 A05.01 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 STAIR 1UNIT B6 UNIT A1 6,417 SF COURTYARD B POOL 6,346 SF COURTYARD A 748 SF COURTYARD C 1,444 SF AMENITY 5' - 1"8 CIRCULATION UNIT B6 STAIR 4 UNIT A1 ELEC ROOM UNIT A1 UNIT A1 UNIT A1 2 UNIT A4 ELEVATOR 3 ELEVATOR 2 ELEVATOR 1 TRASH UNIT A6 1 A06.02 UNIT BA1.1UNIT BA1.1 252 SF ELEC ROOM 10' - 1"2' - 4"8' - 8"2' - 4"13' - 0"2' - 4"6' - 8"2' - 4"8' - 8"2' - 4"9' - 8"1' - 2 97/128" UNIT S2 UNIT A7 UNIT BA1 UNIT BA1 UNIT B1 UNIT B2 UNIT B2.1 4 A06.02 1,234 SF FITNESS MECH EXHAUST SHAFT UNIT B1 MECH SHAFT MECH SHAFT MECH CLOSET MECH SHAFT MECH SHAFT MECH SHAFT 1 A06.10 10' - 0"10' - 0"10' - 0" JAN MECH SHAFT ELEC ROOM MECH SHAFT MECH EXHAUST SHAFT UNIT A7 UNIT B1 UNIT A7 UNIT A5 UNIT S4 UNIT AD2.1UNIT AD2UNIT A1UNIT A1 UNIT B1 UNIT B1 UNIT B1 UNIT AD2 STAIR 2 UNIT A6 UNIT A6UNIT A5UNIT AD2 UNIT B1 UNIT S2 UNIT B6UNIT A6 UNIT B1 UNIT B2 UNIT B2 UNIT B2 UNIT AU1 UNIT AU1 UNIT B2 UNIT AD2 UNIT A8 UNIT B2 UNIT C1 UNIT BA1 UNIT A1 UNIT BA1 UNIT A1 2'-0" x 2'-6" SOFFIT DUCT FOR COORDINATION WITH PME AND STRUCTURAL BOTTOM OF SOFFIT TO BE 7'-6" MIN (FINISHED) LINE OF BUILDING ABOVE FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:42 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.06 2247601 LEVEL 6 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 6 OVERALL FLOOR PLAN UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% DATE DESCRIPTION REV 2 A06.01 2 A06.01 3 A06.02 3 A06.02 3 A06.01 3 A06.01 A05.03 5 4 7 6 STAIR 1 A05.02 3 REFER TO: 1 / A02.06B1,444 SF AMENITY 699 SF UNIT A1 699 SF UNIT A1 1,052 SF UNIT BA1.1 1,052 SF UNIT BA1.1 699 SF UNIT A1 699 SF UNIT A1 699 SF UNIT A1 699 SF UNIT A1 709 SF UNIT A5 635 SF UNIT S4 947 SF UNIT A4 11' - 6 3/4"48' - 3 1/2"11' - 6 1/4" 6,346 SF COURTYARD A 252 SF ELEC ROOM STAIR 2 733 SF UNIT A6 WB1 031 WB1 070 WB1 080 WB1 070 WB1 070 WB1 070 WB1 070 WB1 070 WB1 070 WB1 070 WB1 070 WB1 070 11' - 6 1/4"36' - 10 1/4"UNIT S2 622 SF UNIT S2 WB1 070 WB1 070 WB1 070 24' - 6" 1,037 SF UNIT B1WB1 070 WB1 070 1,023 SF UNIT B2 WB1 070 1,025 SF UNIT B2.1 WB1 070 1,036 SF UNIT B1 1,037 SF UNIT B1 1,037 SF UNIT B1 1,037 SF UNIT B1 12' - 0"5' - 4"9' - 0"5' - 8"12' - 0"676 SF UNIT A7 2'-0" x 2'-6" SOFFIT DUCT FOR COORDINATION WITH PME AND STRUCTURAL BOTTOM OF SOFFIT TO BE 7'-6" MIN (FINISHED) 1,234 SF FITNESS 694 SF UNIT A1 707 SF UNIT A1 840 SF UNIT AD2 875 SF UNIT AD2.1 864 SF UNIT AD2 801 SF UNIT A7 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:45 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.06A 2247601 LEVEL 6 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 6 - ENLARGED FLOOR PLAN - AREA A DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.03 2 13 A05.03 10 9 A05.01 142 SF STAIR 3 8 REFER TO: 1 / A02.06AREFER TO: 1 / A02.06C 6,849 SF CIRCULATION 67 SF ELEVATOR 2 67 SF ELEVATOR 3 699 SF UNIT A1 699 SF UNIT A1 699 SF UNIT A1 699 SF UNIT A1 647 SF UNIT A5 699 SF UNIT A1 1,131 SF UNIT B6 42 SF JAN 6,417 SF COURTYARD B 600 SF POOL 748 SF COURTYARD C 699 SF UNIT A1 699 SF UNIT A1 1,131 SF UNIT B6 142 SFSTAIR 4733 SF UNIT A6 676 SF UNIT A7 864 SF UNIT AD2 1,133 SF UNIT B6 11 SF MECH SHAFT 1 A06.10 5' - 1"10' - 1"25 % O PENINGS ALLOW ED PER NC BUILDING CODE SECTION 705.8 15 % OPENINGS ALLOWED PER N C BUILDING CODE SECTION 705.8 1,037 SF UNIT B1 1,037 SF UNIT B1 733 SF UNIT A6 537 SF UNIT S2 1,037 SF UNIT B1 ELEV LOBBY210 SF ELEC ROOM 1,062 SF UNIT BA1 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:46 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.06B 2247601 LEVEL 6 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 6 - ENLARGED FLOOR PLAN - AREA B DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 1 A06.01 A05.024 REFER TO: 1 / A02.06B 42 SF JAN 142 SFSTAIR 41 A06.02 1 A06.02 4 A06.02 4 A06.02 1 A06.10 WASTE RECYCLE ?SITE TRIANG LESETBACKMECH EXHAUST SHAFT 728 SF UNIT A6 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1 1,016 SF UNIT B2 892 SF UNIT AD2 1,077 SF UNIT B2 664 SF UNIT AU1 673 SF UNIT AU1 1,028 SF UNIT B2 1,145 SF UNIT B2 1,101 SF UNIT B2 26 SF MECH SHAFT 43 SF ELEC ROOM 1,405 SF UNIT C1 849 SF UNIT A8 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:48 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.06C 2247601 LEVEL 6 - ENLARGED FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 6 - ENLARGED FLOOR PLAN - AREA C DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)SETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)1 A06.01 3 A06.02 2 A06.02 3 A06.01 A05.03 5 4 7 6 A05.03 2 13 A05.03 10 9 A05.01 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 STAIR 1STAIR 3 UNIT B6 UNIT A1 UNIT A1 UNIT A5 8 UNIT A3 UNIT A3UNIT A3 UNIT B6 STAIR 4 ELEC ROOM UNIT S4 2 UNIT A4 CIRCULATION 1 A06.02 UNIT BA1.1 UNIT BA1.1 ELEVATOR 2 ELEVATOR 3 TELECOM ELEVATOR 1 TRASH UNIT A6 TRASH ELEC ROOM UNIT A5 UNIT A6 UNIT A6 UNIT BA1 4 A06.02 UNIT S2 UNIT B1UNIT B1 UNIT B1 UNIT B1UNIT B1 UNIT B2.1 UNIT B2 UNIT A7 MECH SHAFT TELECOM TELECOM MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT MECH EXHAUST SHAFT 1 A06.10 UNIT A1 JAN MECH SHAFT TELECOM UNIT B2 UNIT A8 UNIT AD2 UNIT B2 UNIT AU1 UNIT AU1 UNIT B2 UNIT B2 UNIT B2 UNIT A6 UNIT A1 UNIT BA1 UNIT BA1 UNIT A1 UNIT BA1 UNIT C1 UNIT B6 UNIT A2UNIT B1 UNIT A1 UNIT B1 UNIT A7 UNIT A1 TELECOM UNIT A7 UNIT AD2 STAIR 2 UNIT AD2UNIT B1 UNIT AD2 UNIT AD2.1 LINE OF BUILDING ABOVE FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:51 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.07 2247601 LEVELS 7 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 7 OVERALL FLOOR PLAN DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 3 A06.02 3 A06.02 3 A06.01 3 A06.01 A05.03 5 4 7 6 STAIR 1 A05.02 3 REFER TO: 1 / A02.07BTELECOM 1,036 SF UNIT B1 1,052 SF UNIT BA1.1 1,052 SF UNIT BA1.1 1,037 SF UNIT B1 699 SF UNIT A1 865 SF UNIT A3 698 SF UNIT A1 698 SF UNIT A1 676 SF UNIT A7 1,036 SF UNIT B1 865 SF UNIT A3 699 SF UNIT A1 1,037 SF UNIT B1 864 SF UNIT AD2 230 SF ELEC ROOM 1,025 SF UNIT B2.1 1,023 SF UNIT B2 799 SF UNIT A7 710 SF UNIT A5 625 SF UNIT S4 694 SF UNIT A1 707 SF UNIT A1 840 SF UNIT AD2 875 SF UNIT AD2.1 947 SF UNIT A4 622 SF UNIT S2 733 SF UNIT A6 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:54 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.07A 2247601 LEVELS 7 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 7 - ENLARGED FLOOR PLAN - AREA A DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.03 2 13 A05.03 10 9 A05.01 STAIR 3 8 REFER TO: 1 / A02.07AREFER TO: 1 / A02.07C MECH SHAFT TELECOM 1 A06.10 5' - 1"10' - 1"25 % OPENINGS ALLO W ED PER N C BU ILDING CO DE SEC TION 705.8 15 % O PENINGS ALLOW ED PER NC BUILDING CODE SECTION 705.8 1,062 SF UNIT BA1 1,130 SF UNIT B6 699 SF UNIT A1 1,037 SF UNIT B1 699 SF UNIT A1 865 SF UNIT A3 211 SF ELEC ROOM 727 SF UNIT A6 1,133 SF UNIT B6 699 SF UNIT A1 704 SF UNIT A2 1,037 SF UNIT B1 699 SF UNIT A1 676 SF UNIT A7 699 SF UNIT A1 733 SF UNIT A6 733 SF UNIT A6 647 SF UNIT A5 864 SF UNIT AD2 1,131 SF UNIT B6 699 SF UNIT A1 1,037 SF UNIT B1 295 SF ELEV LOBBY JAN ELEVATOR 3 ELEVATOR 2 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:56 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.07B 2247601 LEVELS 7 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 7 - ENLARGED FLOOR PLAN - AREA B DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 1 A06.01 1 A06.01 A05.024 REFER TO: 1 / A02.07B 1 A06.02 1 A06.02 4 A06.02 4 A06.02 MECH EXHAUST SHAFT 1 A06.10 728 SF UNIT A6 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1 1,016 SF UNIT B2 892 SF UNIT AD2 1,077 SF UNIT B2 664 SF UNIT AU1 673 SF UNIT AU1 1,028 SF UNIT B2 1,146 SF UNIT B2 1,101 SF UNIT B2 26 SF MECH SHAFT 43 SF TELECOM WASTE RECYCLE 727 SF UNIT A6 1,405 SF UNIT C1SETBACK 849 SF UNIT A8 JAN FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:43:57 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.07C 2247601 LEVELS 7 - ENLARGED FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 7 - ENLARGED FLOOR PLAN - AREA C DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM 2 A06.01 1 A06.01 3 A06.02 2 A06.02 3 A06.01 A05.03 5 4 7 6 A05.03 2 13 A05.03 10 9 A05.01 8 2 UNIT A4 STAIR 4 ELEC ROOM UNIT B6 UNIT A1 UNIT A1 UNIT A3 UNIT B6 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A3 UNIT A1 UNIT A1 UNIT A1 UNIT A3 STAIR 1ELEVATOR 1 TRASH ELEVATOR 3 ELEVATOR 2 CIRCULATION STAIR 3 1 A06.02 UNIT BA1.1 UNIT BA1.1 UNIT A6 UNIT A6 ELEC ROOM UNIT BA1 UNIT BA1-A 4 A06.02 MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT MECH EXHAUST SHAFT 1 A06.10 JAN MECH SHAFT UNIT B6 UNIT S3-A UNIT A1 UNIT A1 UNIT AD2 UNIT AD2.1 UNIT S2 UNIT B1UNIT B1 UNIT B1 UNIT B1UNIT AD2 UNIT B2.1 UNIT B2 UNIT A7 UNIT A5 UNIT S4 UNIT A7 UNIT B5 UNIT B1 UNIT A7 UNIT A6UNIT A6UNIT A5UNIT AD2 UNIT B1 UNIT A2-A UNIT B6 UNIT B1 UNIT B1 STAIR 2 UNIT B2 UNIT B2 UNIT B2 UNIT AU1 UNIT AU1 UNIT B2 UNIT AD2 UNIT A8 UNIT B2 UNIT C1 UNIT BA1 UNIT A1 UNIT BA1 UNIT A1 UNIT BA1 UNIT A6 STAIR 5 B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:44:08 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.08 2247601 LEVEL 8 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 8 OVERALL FLOOR PLAN DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 3 A06.02 3 A06.02 3 A06.01 3 A06.01 A05.03 5 4 7 6 STAIR 1 A05.02 3 REFER TO: 1 / A02.08BREFER TO: 1 / A02.08B 1,131 SF UNIT B6 540 SF UNIT S3-A 694 SF UNIT A1 707 SF UNIT A1 840 SF UNIT AD2 875 SF UNIT AD2.1 947 SF UNIT A4 622 SF UNIT S2 1,214 SF UNIT B5 1,036 SF UNIT B1 1,052 SF UNIT BA1.1 1,052 SF UNIT BA1.1 1,037 SF UNIT B1 1,037 SF UNIT B1 699 SF UNIT A1 865 SF UNIT A3 699 SF UNIT A1 865 SF UNIT A3 625 SF UNIT S4 709 SF UNIT A5 801 SF UNIT A7 1,023 SF UNIT B2 1,025 SF UNIT B2.1 1,036 SF UNIT B1 698 SF UNIT A1 676 SF UNIT A7 698 SF UNIT A1 1,037 SF UNIT B1 252 SF ELEC ROOM 864 SF UNIT AD2 733 SF UNIT A6 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:44:17 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.08A 2247601 LEVEL 8 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 8 - ENLARGED BUILDING PLAN - AREA A DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.03 2 13 A05.03 10 9 A05.01 STAIR 3 8 REFER TO: 1 / A02.08C MECH SHAFT 1 A06.10 5' - 1"10' - 1"15 % OPENINGS ALLOWED PER NC BUILDING CODE S ECTION 705.8 25 % OPENINGS ALLOWED PER NC BUILDING CODE S ECTION 705.8 1,061 SF UNIT BA1-A 1,131 SF UNIT B6 211 SF ELEC ROOM 699 SF UNIT A1 1,037 SF UNIT B1 699 SF UNIT A1 865 SF UNIT A3 1,131 SF UNIT B6 699 SF UNIT A1 1,037 SF UNIT B1 864 SF UNIT AD2 647 SF UNIT A5 733 SF UNIT A6 733 SF UNIT A6 677 SF UNIT A7 699 SF UNIT A1 699 SF UNIT A1 1,036 SF UNIT B1 699 SF UNIT A1 710 SF UNIT A2-A 1,133 SF UNIT B6 727 SF UNIT A6 295 SF ELEV LOBBY ELEVATOR 3 ELEVATOR 2 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:44:25 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.08B 2247601 LEVEL 8 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 8 - ENLARGED BUILDING PLAN - AREA B DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 1 A06.01 1 A06.01 A05.024 REFER TO: 1 / A02.08B 1 A06.02 1 A06.02 4 A06.02 4 A06.02 1 A06.10 WASTE RECYCLE MECH EXHAUST SHAFT 728 SF UNIT A6 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1 688 SF UNIT A1 1,010 SF UNIT BA1 1,016 SF UNIT B2 892 SF UNIT AD2 1,077 SF UNIT B2 664 SF UNIT AU1 673 SF UNIT AU1 1,028 SF UNIT B2 1,146 SF UNIT B2 1,101 SF UNIT B2 26 SF MECH SHAFT 1,405 SF UNIT C1 849 SF UNIT A8 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:44:33 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.08C 2247601 LEVEL 8 - ENLARGED FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 8 - ENLARGED BUILDING PLAN - AREA C DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM 2 A06.01 1 A06.01 3 A06.02 2 A06.02 3 A06.01 SOUTH CEDAR STREET STADIUM VIEW DRIVE (HILL ST.)SETBACK FOR LIGHT RAILFUTURE BROOKLYN VI LLAGE AVENUE EXTENSI ON (STONEWALL ST.)A05.03 5 4 7 6 A05.03 2 13 A05.03 10 9 A05.01 8 STAIR 3 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 STAIR 1UNIT A1 UNIT B6 STAIR 4 ELEC ROOM UNIT S4 UNIT A3 UNIT A3 UNIT A3 UNIT A5 2 UNIT A4 ELEVATOR 1 ELEVATOR 2 ELEVATOR 1 TRASH 1 A06.02 UNIT BA1.1 UNIT BA1.1 UNIT A6 ELEC ROOM 4 A06.02 MECH SHAFT TELECOM MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT 1 A06.10 JAN UNIT A2 UNIT B6 UNIT B6 UNIT B5 TELECOM UNIT S3 ? ? UNIT A1 UNIT AD2 UNIT AD2.1 UNIT S2 UNIT A7 UNIT B2 UNIT B2.1 UNIT A7 UNIT B1UNIT B1 UNIT B1 UNIT B1 UNIT B1 UNIT AD2 STAIR 2 UNIT A7 UNIT B1 UNIT AD2 UNIT A5 UNIT A6 UNIT A6 UNIT B1UNIT A1UNIT B6 UNIT BA1 TELECOM TELECOM LINE OF BUILDING ABOVE B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:44:42 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.09 2247601 LEVEL 9 OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 9 OVERALL FLOOR PLAN DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 3 A06.02 3 A06.02 3 A06.01 3 A06.01 A05.03 5 4 7 6 STAIR 1 A05.02 3 REFER TO: 1 / A02.09BTELECOM 1,131 SF UNIT B6 539 SF UNIT S3 694 SF UNIT A1 707 SF UNIT A1 840 SF UNIT AD2 875 SF UNIT AD2.1 947 SF UNIT A4 622 SF UNIT S2 1,214 SF UNIT B5 1,036 SF UNIT B1 1,052 SF UNIT BA1.1 1,052 SF UNIT BA1.1 1,037 SF UNIT B1 1,037 SF UNIT B1 699 SF UNIT A1 865 SF UNIT A3 699 SF UNIT A1 865 SF UNIT A3 625 SF UNIT S4 709 SF UNIT A5 801 SF UNIT A7 1,023 SF UNIT B2 1,025 SF UNIT B2.1 1,036 SF UNIT B1 698 SF UNIT A1 676 SF UNIT A7 698 SF UNIT A1 1,037 SF UNIT B1 229 SF ELEC ROOM 862 SF UNIT AD2 733 SF UNIT A6 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:44:51 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.09A 2247601 LEVEL 9 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 9 - ENLARGED FLOOR PLAN - AREA A DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.03 2 13 A05.03 10 9 A05.01 STAIR 3 8 MECH SHAFT TELECOM 1 A06.10 5' - 1"10' - 1"15 % OPENINGS ALLO W ED PER N C BU ILDING CO DE SEC TION 705.8 25 % OPENINGS ALLOWED PER NC BUILDING CODE SECTION 705.8 1,061 SF UNIT BA1 1,131 SF UNIT B6 211 SF ELEC ROOM 699 SF UNIT A1 1,037 SF UNIT B1 699 SF UNIT A1 865 SF UNIT A3 1,131 SF UNIT B6 699 SF UNIT A1 1,037 SF UNIT B1 864 SF UNIT AD2 647 SF UNIT A5 733 SF UNIT A6 733 SF UNIT A6 677 SF UNIT A7 699 SF UNIT A1 699 SF UNIT A1 1,036 SF UNIT B1 699 SF UNIT A1 704 SF UNIT A2 1,133 SF UNIT B6 733 SF UNIT A6 305 SF ELEV LOBBY ELEVATOR 1 ELEVATOR 2 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:44:58 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.09B 2247601 LEVEL 9 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 9 - ENLARGED FLOOR PLAN - AREA B DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 1 A06.01 3 A06.02 2 A06.02 3 A06.01 SETBACK FOR LIGHT RAIL A05.03 5 4 7 6 A05.03 2 13 A05.03 10 9 A05.01 8 STAIR 3 STAIR 4 STAIR 3 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 UNIT A1 STAIR 1UNIT B6 UNIT A1 UNIT B6 STAIR 4 UNIT A1 ELEC ROOM UNIT S4 UNIT A3 UNIT A3 UNIT A5 2 ELEVATOR 3 ELEVATOR 2 ELEVATOR 1 TRASH CIRCULATION UNIT BA1.1 UNIT BA1.1 UNIT A6 ELEC ROOM UNIT A5 UNIT A6 UNIT A6 UNIT A2 MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT MECH SHAFT 1 A06.10 UNIT B6 UNIT B1 UNIT B1 UNIT AD2 UNIT B1 UNIT AD2 UNIT B1 UNIT A7 UNIT A7 UNIT B1 JAN UNIT S3 UNIT A1 UNIT A1 UNIT B6 UNIT S2 UNIT B2 UNIT B2.1 UNIT B1 UNIT B1UNIT B1 UNIT B5 UNIT AD2.1UNIT AD2 UNIT A7 STAIR 2 UNIT BA1-A UNIT A4 LINE OF BUILDING ABOVE FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:45:07 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.10 2247601 LEVEL 10 - OVERALL FLOOR PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 LEVEL 10 OVERALL FLOOR PLAN DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 3 A06.02 3 A06.02 3 A06.01 3 A06.01 A05.03 5 4 7 6 STAIR 1 A05.02 3 REFER TO: 1 / A02.10B733 SF UNIT A6 24' - 7 11/16"1,131 SF UNIT B6 539 SF UNIT S3 694 SF UNIT A1 707 SF UNIT A1 840 SF UNIT AD2 875 SF UNIT AD2.1 947 SF UNIT A4 622 SF UNIT S2 1,214 SF UNIT B5 1,036 SF UNIT B1 1,052 SF UNIT BA1.1 1,052 SF UNIT BA1.1 1,037 SF UNIT B1 1,037 SF UNIT B1 699 SF UNIT A1 865 SF UNIT A3 699 SF UNIT A1 865 SF UNIT A3 623 SF UNIT S4 709 SF UNIT A5 801 SF UNIT A7 1,023 SF UNIT B2 1,025 SF UNIT B2.1 1,036 SF UNIT B1 698 SF UNIT A1 676 SF UNIT A7 698 SF UNIT A1 1,037 SF UNIT B1 252 SF ELEC ROOM 862 SF UNIT AD2 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:45:15 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.10A 2247601 LEVEL 10 - ENLARGED FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 10 - ENLARGED FLOOR PLAN - AREA A DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 2 A06.01 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.03 2 13 A05.03 10 9 A05.01142 SFSTAIR 38 REFER TO: 1 / A02.10A11 SF MECH SHAFT 1 A06.10 1,061 SF UNIT BA1-A 1,131 SF UNIT B6 699 SF UNIT A1 1,037 SF UNIT B1 JAN 733 SF UNIT A6 699 SF UNIT A1 865 SF UNIT A3 1,131 SF UNIT B6 699 SF UNIT A1 1,037 SF UNIT B1 863 SF UNIT AD2 647 SF UNIT A5 733 SF UNIT A6 733 SF UNIT A6 699 SF UNIT A1 677 SF UNIT A7 699 SF UNIT A1 11 SF MECH SHAFT 1,036 SF UNIT B1 699 SF UNIT A1 704 SF UNIT A2 1,133 SF UNIT B6ELEVATOR 3 ELEVATOR 2STAIR 4211 SF ELEC ROOM PROPERTY LINE5' - 1"10' - 1"15 % OPENINGS ALLOWE D PER NC BUILDING CODE SECTION 705.8 25 % OPENINGS ALLOWED PER N C BUILDING CODE SECTION 705.8 FLOOR PLAN NOTES 1. ALL DIMENSIONS ARE TO THE FACE OF STUD UNLESS OTHERWISE NOTED. 2. REFER TO SHEET A00.70 THRU A00.74 FOR PARTITION DETAILS. 3. REFER TO STRUCTURAL DRAWINGS FOR ALL EXTERIOR LOADBEARING WALLS. EXTERIOR LOADBEARING WALLS ARE TO BE CONSTRUCTED PER UL# U349 AND NON-LOADBEARING WALLS UL# U356 4. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 5. ALL CORRIDOR WALL ARE 1-HR RATED PER UL# U305 6. SEE UNIT PLANS (A4 SERIES) AND ENLARGED CORE PLANS (A3 SERIES) FOR ADDITIONAL WALL OR DOOR TAGS. 7. ALL TENANT SEPARATION WALL ARE 1-HR RATED PER UL# U341. 8. REFER TO SP-05 FOR ADDRESSING PLAN 9. PIPE SAFETY GUARDS -PROVIDE GUARDS AROUND EVERY VERTICAL PIPE (STORM, SANITARY, ETC.) IN THE PARKING GARAGE TO PROTECT THE PIPES FROM DAMAGE. UNIT TYPE LEGEND BASE UNIT UNIT VARIATION TYPE A UNIT SPRAY-APPLIED INSULATION UNDER PODIUM SLAB -R-10 Cl TYPE III-A (WOOD STUD) CONSTRUCTION = B1 TYPE I-A (METAL STUD) CONSTRUCTION = B1M B1.1 B1.1M B1-A B1-AM B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:45:23 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.10B 2247601 LEVEL 10 - ENLARGED FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 LEVEL 10 - ENLARGED FLOOR PLAN - AREA B DATE DESCRIPTION REV UNIT MIX SUMMARY (ROOMS) UNIT NAME UNIT TYPE AVERAGE UNIT AREA COUNT TOTAL SF % of UNITS UNIT A1 1 BR / 1 BA 701 SF 81 56,755.68 SF 21.66% UNIT A2 1 BR / 1 BA 704 SF 3 2,113.04 SF 0.80% UNIT A2-A 1 BR / 1 BA 710 SF 1 710.39 SF 0.27% UNIT A3 1 BR / 1 BA 865 SF 12 10,381.81 SF 3.21% UNIT A4 1 BR / 1 BA 965 SF 8 7,718.90 SF 2.14% UNIT A5 1 BR / 1 BA 678 SF 10 6,780.54 SF 2.67% UNIT A6 1 BR / 1 BA 730 SF 30 21,900.57 SF 8.02% UNIT A7 1 BR / 1 BA 718 SF 15 10,763.03 SF 4.01% UNIT AU1 1 BR / 1 BA 668 SF 12 8,013.56 SF 3.21% 1 BR / 1 BA: 172 172 125,137.52 SF 45.99% UNIT AD2 1 BR / 1 BA / D 864 SF 24 20,727.18 SF 6.42% UNIT AD2.1 1 BR / 1 BA / D 890 SF 8 7,122.61 SF 2.14% 1 BR / 1 BA / D: 32 32 27,849.79 SF 8.56% UNIT A8 2 BR / 2 BA 849 SF 6 5,091.49 SF 1.60% UNIT B1 2 BR / 2 BA 1,036 SF 40 41,458.11 SF 10.70% UNIT B2 2 BR / 2 BA 1,064 SF 33 35,100.01 SF 8.82% UNIT B2.1 2 BR / 2 BA 1,025 SF 5 5,124.92 SF 1.34% UNIT B3 2 BR / 2 BA 1,026 SF 6 6,156.54 SF 1.60% UNIT B5 2 BR / 2 BA 1,214 SF 3 3,643.02 SF 0.80% UNIT B6 2 BR / 2 BA 1,132 SF 18 20,368.27 SF 4.81% UNIT BA1 2 BR / 2 BA 1,017 SF 19 19,327.57 SF 5.08% UNIT BA1-A 2 BR / 2 BA 1,036 SF 4 4,143.12 SF 1.07% UNIT BA1.1 2 BR / 2 BA 1,052 SF 10 10,517.18 SF 2.67% UNIT C1 2 BR / 2 BA 1,403 SF 6 8,418.53 SF 1.60% 2 BR / 2 BA: 150 150 159,348.76 SF 40.11% UNIT S2 STUDIO 611 SF 9 5,498.66 SF 2.41% UNIT S3 STUDIO 538 SF 4 2,150.82 SF 1.07% UNIT S3-A STUDIO 539 SF 2 1,077.49 SF 0.53% UNIT S4 STUDIO 627 SF 5 3,133.17 SF 1.34% STUDIO: 20 20 11,860.13 SF 5.35% Grand total 374 324,196.20 SF 100.00% AVERAGE NET AREA PER UNIT (ROOMS) AVERAGE UNIT NET AREA COUNT TOTAL SF % of UNITS 866.83 SF 374 324,196.20 SF 100.00% 2 A06.01 1 A06.01 3 A06.02 2 A06.02 3 A06.01 A05.03 5 4 7 6 A05.03 2 13 A05.03 10 9 A05.01 8 2 A02.11A 1 A02.11B 1 A02.11C 2 1 A06.10 PROPERTY LINE PROPERTY LINE SETBACKPOWER LINEEASEMENT1 2 1 /2 5 6 " B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:45:28 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.11 2247601 OVERALL ROOF PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 OVERALL ROOF PLAN DATE DESCRIPTION REV 2 A06.01 2 A06.01 3 A06.02 3 A06.02 3 A06.01 3 A06.01 A05.03 5 4 7 6 A05.02 3 REFER TO: 1 / A02.11BC dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:45:31 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.11A 2247601 ENLARGED ROOF PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 HIGH ROOF - ENLARGED ROOF PLAN - AREA A DATE DESCRIPTION REV 2 A06.01 2 A06.01 1 A06.01 1 A06.01 2 A06.02 2 A06.02 3 A06.01 3 A06.01 A05.03 2 13 A05.03 10 9 A05.01 8 REFER TO: 1 / A02.11A1 A06.10 PROPERTY LINE B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:45:34 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.11B 2247601 ENLARGED ROOF PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"1 HIGH ROOF - ENLARGED ROOF PLAN - AREA B DATE DESCRIPTION REV 1 A06.01 1 A06.01 A05.024 1 A06.02 1 A06.02 4 A06.02 4 A06.02 1 A06.10 B A CBUILDING 2BUILDING 1 BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 1:45:37 PM C:\Users\AGladden\Documents\Revit\2247601_MCRT_Foundry_Option 5_agladdenF5NHC.rvtA02.11C 2247601 ENLARGED ROOF PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/8" = 1'-0"2 LOW ROOF - ENLARGED ROOF PLAN - AREA C DATE DESCRIPTION REV UP UP LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 7 A03.01 9' - 3"9' - 3"9' - 3"9' - 3"11' - 6"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 6 A03.01 7 A03.01 6 A03.01 STAIR 1 7 6 7 A03.01 6 A03.01 STAIR 1 7 6 7 A03.01 6 A03.01 7 6 7 A03.01 6 A03.01 7 A03.01 6 A03.01 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:49:41 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.01 2247601 STAIR 1 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"6 STAIR 01 - SECTION 1 1/4" = 1'-0"7 STAIR 01 - SECTION 2 1/4" = 1'-0"5 STAIR 01 - LEVEL 10 1/4" = 1'-0"3 STAIR 01 - LEVELS 3-5 1/4" = 1'-0"1 STAIR 01 - LEVEL 1 1/4" = 1'-0"2 STAIR 01 - LEVEL 2 (LEVEL OF DISCHARGE) 1/4" = 1'-0"4 STAIR 01 - LEVELS 6-9 DATE DESCRIPTION REV 1 5 A03.02 6 A03.02 5 A03.02 6 A03.02 5 A03.02 6 A03.02 LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 6 A03.02 LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 5 A03.02 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:49:45 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.02 2247601 STAIR 2 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 STAIR 4 - LEVELS 5-6 1/4" = 1'-0"2 STAIR 4 - LEVELS 7-9 1/4" = 1'-0"3 STAIR 4 - LEVEL 10 DATE DESCRIPTION REV 1/4" = 1'-0"5 STAIR 02 - SECTION 1 1/4" = 1'-0"6 STAIR 02 - SECTION 2 6 A03.03 7 A03.03 STAIR 3 B LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 7 A03.03 LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 6 A03.03 6 A03.03 7 A03.03 B 6 A03.03 7 A03.03 6 A03.03 7 A03.03 B 6 A03.03 7 A03.03 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:49:50 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.03 2247601 STAIR 3 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"3 STAIR 3 - LEVEL 5 1/4" = 1'-0"6 STAIR 3 - SECTION 1 1/4" = 1'-0"7 STAIR 3 - SECTION 2 1/4" = 1'-0"2 STAIR 3 - LEVEL 4 (LEVEL OF DISCHARGE) 1/4" = 1'-0"5 STAIR 3 - LEVEL 10 1/4" = 1'-0"1 STAIR 3 - LEVELS 2-3 1/4" = 1'-0"4 STAIR 3 - LEVELS 6-9 DATE DESCRIPTION REV C 5 A03.04 6 A03.04 8 C 5 A03.04 6 A03.04 8 V 5 A03.04 6 A03.04 LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 6 A03.04 10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" 5 A03.04 C 5 A03.04 6 A03.04 8 V C 5 A03.04 6 A03.04 8 5 A03.04 6 A03.04 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:49:55 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.04 2247601 STAIR 4 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"3 STAIR 04 - LEVEL 5 1/4" = 1'-0"2 STAIR 04 - LEVEL 3 1/4" = 1'-0"4 STAIR 04 - LEVEL 10 1/4" = 1'-0"5 STAIR 04 - SECTION 1 1/4" = 1'-0"6 STAIR 04 - SECTION 2 1/4" = 1'-0"1 STAIR 04 - LEVEL 1 1/4" = 1'-0"7 STAIR 04 - LEVEL 4 1/4" = 1'-0"8 STAIR 04 - LEVELS 6-9 DATE DESCRIPTION REV 5 A03.05 4 A03.05 LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LOW ROOF F.F.E. = 745' -6" 5 A03.05 10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LOW ROOF F.F.E. = 745' -6" 4 A03.05 9' - 3"9' - 3"9' - 3"9' - 3"11' - 6"10' - 8"10' - 8"10' - 8"5 A03.05 4 A03.05 14 V 5 A03.05 4 A03.05 5 A03.05 4 A03.05 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:50:00 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.05 2247601 STAIR 5 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"2 STAIR 05 - LEVELS 3-5 1/4" = 1'-0"4 STAIR 05 - SECTION 1 1/4" = 1'-0"5 STAIR 05 - SECTION 2 1/4" = 1'-0"1 STAIR 05 - LEVEL 1 (LEVEL OF DISCHARGE) 1/4" = 1'-0"3 STAIR 05 - LEVELS 6-7 1/4" = 1'-0"6 STAIR 05 - LEVEL 8 DATE DESCRIPTION REV CONCRETE SLAB ON GRADE PRECAST CONCRETE TREAD ATTACHED TO METAL STRINGER WITH ANGLES, PROTECT DURING CONSTRUCTION FROM DAMAGE METAL CLOSURE PANEL BETWEEN RISERS, PAINTED STEEL BENT PLATE STAIR SUPPORT, ATTACHED TO LVL BEAM, SEE STRUCTURAL (2) 1/2" DIA. EXPANSION BOLTS @ 5" O.C. -SEE STRUCTURAL STEEL STRINGER, PAINTED 3"RISER4" - 7"STEEL STRINGER, PAINTED 14 GAUGE BENT PLATE FROM STRINGER TO STRINGER AT ALL RISERS TO CREATE CLOSED RISERS AT ALL METAL STAIRS (BOTH ENDS PAINTED)RISER7" MAX2"1"10"0' - 2 1/2" PRECAST CONCRETE TREAD 1 1/2"3' - 6"1 1/2" SEE STAIR PLANS FOR VARIATIONS 4' - 0" MIN CLEAR 1 1/2"2 3/4" 1 1/2" 1 1/2" SEE STAIR PLANS FOR VARIATIONS 4' - 0" MIN CLEAR 2' - 10"WELDED CLIP ANGLES TO STRINGER STEEL STRINGERS, PAINTED METAL BRACKET AT 4' -0" O.C. TYP. MECHANICAL FASTENERS TYP. STAIR TREAD 1 1/2" O.D. STEEL GUARDRAIL, PRIMED AND PAINTED 5/8" BAR PICKETS AT 4" O.C. MAX, PAINTED 1 1/2" O.D. STEEL BOTTOM RAIL 1 1/2" DIA. METAL HANDRAIL SECURED TO GUARDRAIL BY BRACKET AT EACH 1 1/2" SQ. INTERMEDIATE VERTICAL SUPPORT, TYP.2"FCA 3 STEEL GUARDRAIL POST WELDED CLIP ANGLES TO STRINGER STEEL STRINGERS, PAINTED STAIR TREAD 2 1/4" CONCRETE TOPPING- BROOM FINISH METAL DECKING, SEE STRUCTURAL DWGS. METAL POUR STOP CONTINUOUS SEALANT GROUT SOLID BEHIND ALL STAIR SUPPORT LOCATIONSSTEEL STAIR SUPPORT, SEE STRUCTURAL DWGS.3' - 6"8' - 8 3/4" 4' - 3"2 3/4"4' - 3" 1 1/2" 3" 3/8" OC BOLT, TYP. PRECAST TREAD 2 1/4" X 12" X 4'-0" 14 GAUGE METAL PLAN WELDED TO STRINGERS, PAINTED 42" HIGH GUARDRAIL, PAINTED MIN 11"1" MIN 11" 1" TREAD DEPTH 11"REJECT ø 0' - 4" REJECT ø 0' - 4" PAINT2 1/4"MIN 12" 4' - 0" MAX EQ 4' - 0" MAX EQ 4' - 0" MAX EQ 4' - 0" MAX EQ 2' - 10"WALL MOUNTED BRACKET ATTACHMENT VARIES WITH WALL CONSTRUCTION 1 1/2" O.D. 13 GA. TUBE TREAD DEPTH 11" INSIDE FACE OF STAIR CORE WALL 2' - 10"MAX27"CANE DETECTION RAIL MINIMUM HEAD ROOM6' - 8"CLOSED END (SMOOTH) 12" MIN. FIRST OR FINAL STAIR RISER, OR EDGE OF RAMP WALL BRACKET, PROVIDE BLOCKING BEHIND FOR ATTACHMENT CLOSED END (SMOOTH) CMU 1 1/2" STEEL TUBE HANDRAIL, PAINTED BASE PLATE AT MOUNTING SUPPORT MECHANICAL FASTENERS2 1/4"1 1/2" MAX.REJECT ø 0' - 4" REJECT ø 0' - 4" METAL POUR STOP STEEL STRINGER, PAINTED STEEL BEAM, SEE STRUCTURAL DWGS. CONCRETE TOPPING- BROOM FINISH METAL DECKING, SEE STRUCTURAL DWGS. MIN 11" 1" MIN 11" 1" 1"2 1/2" METAL END CAPS (TYP) 1 1/2" X 11 GA. TUBE POSTS @ QUARTER POINTS OF RAIL. WELD TO STRINGERS WITH 1/4" WEB STIFFENERS AT HANDRAIL POST LOCATIONS. 1 1/2" O.D. X 13 GA. TUBING 42" HIGH GUARDRAIL. 5/8" DIA STEEL BAR PICKET. PAINTED 3 3/4"3' - 6"2' - 10"A03.06 5 TYP PRECAST CONCRETE TREAD ATTACHED TO METAL STRINGER WITH ANGLES, PROTECT DURING CONSTRUCTION FROM DAMAGE METAL CLOSURE PANEL BETWEEN RISERS, PAINTED STEEL STRINGER, PAINTED 3" METAL POUR STOP STEEL BEAM, SEE STRUCTURAL DWGS. CONCRETE TOPPING- BROOM FINISH METAL DECKING, SEE STRUCTURAL DWGS. 1" MIN 11" PRECAST TREADS, ANCHORED WITH ANGLES TO STEEL STRINGER, PROTECT DURING CONSTRUCTION FROM DAMAGE STEEL STRINGER, PAINTED METAL POUR STOP METAL CLOSURE BETWEEN RISERS, PAINTED SEE STRUCTURAL DWGS. FOR STRINGER TO STEEL BEAM ATTACHMENT STEEL BEAM, SEE STRUCTURAL DWGS. CONCRETE TOPPING-BROOM FINISHMETAL DECKING, SEE STRUCTURAL DWGS. 1" MIN 11" 1" ONE-WAY BARRIER GATEGATE WIDTH 4' - 0"TOP OF GATE32"FLOOR MOUNTED METAL POST WELDED TO BASE ANGLE PLATE VERTICAL METAL PICKETS 1/2" DIA. EXPANSION BOLTS @ 48" O.C - SEE STRUCTURAL BASE ANGLE PLATE BOLTED TO THE FLOOR FLOOR COMPONENT BOTTOM GUARD RAIL TOP METAL RAILING 3' - 6"0' - 9"27" MAX80" MIN.CANE DETECTION AREA COMPLY WITH ANSI A117.1 FIG. 307.4 WELD 2 1/4" X 1/4" ST; STRAP "Z" BRACING TO STEEL STRINGER, SEE STRUCTURAL STEEL STAIR STRINGER, SEE STRUCTURAL PRECAST CONCRETE TREAD C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:50:04 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.06 2247601 STAIR DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1 1/2" = 1'-0"1 STAIR DETAIL AT BASE 3" = 1'-0"5 PRECAST CONCRETE TREAD DETAIL 1 1/2" = 1'-0"9 STAIR TRANSVERSE SECTION 1 1/2" = 1'-0"10 STAIR HANDRAIL AT BASE 1/2" = 1'-0"11 HANDRAIL - ELEVATION 3" = 1'-0"6 HANDRAIL DETAIL AT ADJACENT WALL - CMU 1 1/2" = 1'-0"7 STAIR HANDRAIL AT TOP 1 1/2" = 1'-0"3 STAIR LANDING DETAIL STL - BOTTOM 1 1/2" = 1'-0"4 STAIR LANDING DETAIL STL - TOP 1/2" = 1'-0"13 ONE-WAY BARRIER ELEVATION 1 1/2" = 1'-0"8 FLOOR MOUNTED RAILING DETAIL - METAL 1/4" = 1'-0"14 CANE DETECTION REQUIREMENT 3" = 1'-0"2 'Z' BRACING DETAIL DATE DESCRIPTION REV 3' - 6"SEE STAIR PLANS FOR VARIATIONS 4' - 0" CLEAR 0' - 1 1/2"VARIES 0' - 1 1/2" SEE STAIR PLANS FOR VARIATIONS 3' - 8" MIN. CLEAR 2' - 10"5" MIN METAL BRACKET AT 4' -0" O.C. TYP. ANCHOR BOLTS AT EACH BRACKET 1 1/2" O.D. STEEL GUARDRAIL, PRIMED AND PAINTED 5/8" BAR PICKETS AT 4" O.C. MAX, PAINTED 1 1/2" O.D. STEEL BOTTOM RAIL 1 1/2" DIA. METAL HANDRAIL SECURED TO GUARDRAIL BY BRACKET AT EACH 1 1/2" SQ. INTERMEDIATE VERTICAL SUPPORT, TYP. STEEL GUARDRAIL POST 1 1/2" MIN GROUT SOLID AT WALL BRACKET LOCATION PRECAST BY OTHERS PRECAST BY OTHERS PRECAST BY OTHERS PAINTED INSIDE FACE OF STAIR CORE WALL 0' - 1 3/4"4' - 0" MAX EQ 4' - 0" MAX EQ 4' - 0" MAX EQ 4' - 0" MAX EQ 4'-0" Max EQ 4' - 0" MAX 2' - 4" WALL MOUNTED BRACKET ATTACHMENT VARIES WITH WALL WALL CONSTRUCTION 1 1/2" O.D. 13 GA. TUBE MINIMUM HEADROOM6' - 8"MAX27"CANE DETECTION RAIL 2' - 10"PRECAST BY OTHERS. 1' - 0" STEEL ANGLE BY STAIR MANUFACTURER FASTEN TO FLOOR W/ EXPANSION ANCHOR 42" HIGH GUARDRAIL, PAINTED ALIGN POST (CENTER LINE) W/ STAIR NOSING POINT 34" HIGH HANDRAIL 1 1/2" DIAMETER, PAINTED; RETURN HANDRAIL TO POST 12"34"1 1/2" SQ TUBE STEEL GUARDRAIL AND POST, PRIMED AND PAINTED 5/8" BAR PICKETS AT 4" O.C. MAX, PAINTED REJECT ø 0' - 4" 1 1/2" SQ TUBE STEEL BOTTOM RAIL, PRIMED AND PAINTED PRECAST BY OTHERS. 0' - 4 1/4" GATE 3' - 6"0' - 4 3/4" SELF-CLOSING GATE HINGE 1 1/4" DIA. PIPE GATE FRAME 2 1/2" X 1 1/2" HOLLOW STEEL SECTION WITH (2) 1/4" MOUNTING PLATES ANCHORED TO WALL. PROVIDE ADEQUATE WOOD BLOCKING IN WALL AT ATTACHMENT LOCATION STAIRS WALL WALL TOP VIEW 2' - 8"4' - 4".0' - 8"STAIR 4 FLOOR LINE FRONT -1/4" CLEAR ACRYLIC FROSTED P9S 2ND SURFACE PAINTED / EDGES CLEAR TACTILE ICON 1/32" PIGMENTED ROWMARK ON 1ST SURFACE TACTILE ICON 1/32" PIGMENTED ROWMARK ON 1ST SURFACE 0' - 6" NOTE: AT THE DOOR THAT LEADS TO THE OUTSIDE, THERE SHOULD BE ADDITIONAL RAISED AND BRAILLE SIGNAGE INDICATING "EXIT". STAIR LEVEL IDENTIFICATION SHALL COMPLY WITH ICC A117.1-2009 SECTION 504.9 AT THE DOOR THAT LEADS TO THE OUTSIDE, THERE SHOULD BE ADDITIONAL RAISED AND BRAILLE SIGNAGE INDICATING "EXIT". STAIR LEVEL IDENTIFICATION SHALL COMPLY WITH ICC A117.1-2009 SECTION 504.9 -1' - 6"MIN. 1/4" THICK NON TRANSLUCENT PLASTIC SIGN PANEL ALUMINUM PIN ATTACHMENTS TO WALL, HOLD SIGN OFF WALL 1/2" 2" UPPER CASE STAIR DESIGNATION LETTERING 1" LOWER CASE ROOF ACCESS DESIGNATION PROVIDE TACTILE LETTERING FOR EACH DESIGNATION 5" UPPERCASE FLOOR LEVEL DESIGNATION (LOCATE NUMBER IN CENTER OF SIGN) 2" LOWER CASE LETTERING 1" LOWER CASE LETTERING FOR EXIT LEVEL DESIGNATION 1" UPPER CASE FLOOR CONNECTION DESIGNATION NOTE: 1. ALL LETTERING TO BE RAISED FROM PANEL 1/4" AND BE OF A CONTRASTING COLOR. 2. CHARACTERS AND THEIR BACKGROUND SHALL HAVE A NON-GLARE FINISH. 3. CHARACTERS SHALL CONTRAST WITH THEIR BACKGROUND, WITH EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND. 4. SIGNAGE SHALL STATE THE STORY OF, AND THE DIRECTION TO, THE EXIT DISCHARGE. FLOOR LANDING LINE5"1 3/4"3/4"7 1/4"3/4"2 1/2"3' -8"1' - 2" NO STORAGE ALLOWED IN THIS ROOM 1' - 0"0' - 6"MOUNT SIGN 60" A.F.F. 60"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:50:08 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.07 2247601 STAIR DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1 1/2" = 1'-0"1 STAIR TRANSVERSE SECTION AT STEEL (PRECAST) 1/2" = 1'-0"2 HANDRAIL - ELEVATION (PRECAST) 1 1/2" = 1'-0"3 STAIR HANDRAIL AT BASE (PRECAST) 1" = 1'-0"4 SINGLE SWING GATE DETAIL 6" = 1'-0"7 EXTERIOR STAIR SIGNAGE 1 1/2" = 1'-0"5 TACTILE EXIT SIGN 3" = 1'-0"6 STAIR SIGNAGE DETAIL DATE DESCRIPTION REV A03.08 1 TYP.8 1/8"9 7/8" 1-1/4" PIPE HANDRAIL 1 ' - 0 5 /8 " 2 HR RATED 30"X 96" ROOF ACCESS HATCH. CENTERED ON TREAD DEVICE BELOW AS REQUI RED8' - 0" 2 HR RATED ROOF ASSEMBLY PROVIDE LOCKABLE GATE MAINTAIN 2 HR CEILING ASSEMBLY, WRAPPED INTO ACCESS HATCH CURB ON ROOF AROUND ACCESS HATCH TYPICAL STAIR FLOOR / CEILING ASSEMBLY18" CURBMETAL DECKING, SEE STRUCTURAL DWGS. METAL POUR STOP STEEL STAIR SUPPORT, SEE STRUCTURAL DWGS. GRANULE SURFACED MODIFIED BITUMEN BASE FLASHING P.T. 1X4 WOOD OR MANUFACTURED CANT FASTENED W/ RING SHANK NAILS APPROVED ROOFING MATERIAL APA RATED STRUCTURAL DECK APPROVED ROOF HATCH 1 1/2" RIGID FIBERBOARD INSULATION CURB WITH INTEGRAL CAP FLASHING CURB FLANGE ATTACH TO ROOF DECK PER MANUFACTURE'S RECOMMENDATIONS PROVIDE HATCH RAIL SYSTEM AND SUPPORTS 3' - 6"18" CURBFIBERGLASS REINFORCED POLYMER (FRP), YELLOW, UV RESISTANT & FIRE RETARDANT. D = 1.19"SURFACE OR DECK42" ABOVE THE ROOFALUMINUM POST HINGE STAINLESS STEEL TORSION ROD ALUMINUM GATE HINGE SELF CLOSING RFP GATE. D = 1.91" STEEL CORNER BRACKETS, HOT DIP GALVANIZED ALUMINUM POST SUPPORTS BASIS OF DESIGN: BILCO BIL-GUARD TYPE NB HATCH RAIL SYSTEM. SINGLE LEAF ROOF SCUTTLE C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:50:11 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.08 2247601 STAIR DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"2 ALTERNATE TREAD DEVICE - SECTION DETAIL 1 1/2" = 1'-0"1 ROOF HATCH & FLASHING DETAIL 1 1/2" = 1'-0"3 HATCH RAIL SYSTEM AND SUPPORTS DATE DESCRIPTION REV 3 A03.09 2 A03.09 3 A03.09 2 A03.09 3 A03.09 2 A03.09 LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" AGP BLDG 2 F.F.E. = 672' -2" AGP BLDG 1 F.F.E. = 690' -0" 3 A03.09 LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" AGP BLDG 2 F.F.E. = 672' -2" AGP BLDG 1 F.F.E. = 690' -0" 2 A03.09 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:50:15 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.09 2247601 ELEVATOR 1 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 ELEVATOR 1 - LEVEL 5 1/4" = 1'-0"4 ELEVATOR 1 - ROOF PLAN 1/4" = 1'-0"5 ELEVATOR 1 - LEVEL 7 DATE DESCRIPTION REV 1/4" = 1'-0"2 ELEVATORS 01 SECTION 1 1/4" = 1'-0"3 ELEVATOR 01 SECTION 2 D 7 7 A03.10 6 A03.10 D 7 7 A03.10 6 A03.10 O D 7 7 A03.10 6 A03.10 O 7 A03.10 6 A03.10 7 A03.10 6 A03.10 LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" HIGH ROOF F.F.E. = 766' -10" 7 A03.10 10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"5' - 0" PIT DEPTHLEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" HIGH ROOF F.F.E. = 766' -10" 6 A03.10 5' - 0"9' - 3"9' - 3"9' - 3"9' - 3"11' - 6"10' - 8"10' - 8"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:50:20 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.10 2247601 ELEVATOR 2 AND 3 SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"3 ELEVATOR 2 AND 3 - LEVEL 5 PLAN 1/4" = 1'-0"1 ELEVATOR 2 AND 3 - LEVEL 2 PLAN 1/4" = 1'-0"2 ELEVATOR 2 AND 3 - LEVELS 3-4 PLAN 1/4" = 1'-0"5 ELEVATOR 2 AND 3 - ROOF PLAN 1/4" = 1'-0"4 ELEVATOR 2 AND 3 - LEVEL 7 PLAN DATE DESCRIPTION REV 1/4" = 1'-0"6 ELEVATOR2 AND 3 - SECTION 1 1/4" = 1'-0"7 ELEVATOR 2 AND 3 - SECTION 2 ROOF MEMBRANE ATTACHED TO SHEATHING TYPICAL ROOF / CEILING ASSEMBLY PREMANUFACTURED WOOD TRUSS 5/8" GWB. MAINTAIN 2 HR CEILING ASSEMBLY 2 x 10 BAND BOARD AND FRAMING WOOD ROOF DECK SHEATHING TAPERED INSULATION TO CREATE A 1/4" PER 1'-0" SLOPE WRAP ROOF MEMBRANE OVER ROOF EDGE AND DOWN WALL BOND BEAM 2 HOUR RATED CMU ELEVATOR WALL PRESSURE TREATED WOOD SILL PLATES ROOF MEMBRANE RUN UP WALL HEAT WELD TERMINATION BAR -APPLY ROOF SYSTEM WATER STOP BEHIND MEMBRANE AND TERMINATION BAR. SEAL TOP OF TERMINATION BAR WITH COVE BEAD SEALANT HEAT WELD ROOF MEMBRANE FROM UPPER ROOF LAP OVER TERMINATION BAR AND HEAT WELD TO LOWER MEMBRANE MECHANICALLY FASTEN ROOF MEMBRANE AS NEEDED AT EDGE CONDITION, PER MANUF. RECOMMENDATIONSSEE MANUF.1' - 0" MIN.FASTENERS @ 8" O.C. MIN. OF 2" HIGH DOMED, CAPPED & GASKETED FASTENERS 18" O.C. PER SIDE ROOF MEMBRANE WOOD CANT STRIP 2X10 P.T. WOOD REMOVABLE SHEET METAL COUNTER FLASHING ROOF HOOD, SEE MECH. TAPERED INSULATION TO CREATE A 1/4" PER 1'-0" SLOPE 0' - 0 5/8"0' - 2" CMU WALL SEALANT 5/8" TYPE 'X' GYP. BOARD ELEVATOR SHAFT CORRIDOR FLOOR DESIGNATION BELOW CENTERED IN FRAME WIDTH 0' - 2"CMU HEADER -SEE STRUCTURAL FOR REINFORCING 5/8" TYPE 'X' GYP. BD. MECHANICALLY ATTACHED TO STUDS 7/8" FURRING CHANNEL SEALANT ELEVATOR DOOR FRAME 7' -0" CLEAR OPENINGELEVATOR DOOR FRAME HEADER TRACK FASCIA ELEVATOR SHAFT DOOR HANGER (NON METALLIC FACED ROLLERS WITH THRUST ROLLERS CORRIDOR TOP OF SILL SUPPORT FINISH FLOOR FINISH FLOOR (LIGHTWEIGHT CONCRETE) TYPICAL 1 HR RATED FLOOR/CEILING 5/8" TYPE 'X' GYP BD. 8" CMU. WALL CORRIDOR ELEVATOR SHAFT 16" CMU LINTEL BLOCK GROUT SOLID TOE GUARD SEE STRUCTURAL FOR ANCHOR BOLTS STEEL ANGLE FULL WIDTH OF HOIST0' - 2 1/2"DOOR FRAME BEYOND ELEVATOR DOOR FACE OF CAB 0' - 6 1/2"0' - 1 1/4" 0' - 0 1/4" SILL BY ELEVATOR MFR SIGHT GUARD CONCRETE SLAB WATERSTOP CONCRETE ELEVATOR PIT WALL. SEE STRUCTURAL DWGS. CONCRETE FOOTING, SEE STRUCTURAL DWGS. SUMP PIT IN CORNER OF ELEVATOR. 1/2" X 1 1/2" METAL GRATE OVER TOP SET IN LIP PROVIDE LIGHT ABOVE LADDER ELEVATOR LOBBY S 1' - 6" LADDER TO PIT 18" WIDE W/ 3" STRINGER CHAN. AND 3/8" STEEL CLIP ANGLE BRACKETS AT TOP AND BOTTOM ANCHOR BOLTS. RUNS TO BE 3/4" @ 12" O.C. ELEVATOR SILL ANGLE SILL ANGLE EMBEDED PLATE SEE STRUCTURAL DWGS. SUMP PIT SEE MECH. FOR LOCATION, PROVIDE WATERPROOFING AT ALL JOINTS IN CONCRETE WATERSTOP 5' - 0"4' - 0"MAX0' - 11 241/256"TYP1' - 0"60 MIL, SELF ADHERING BELOW GRADE WATERPROOFING WITH PROTECTION BOARD C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:50:22 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA03.11 2247601 TYPICAL ELEVATOR DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1 1/2" = 1'-0"1 ELEVATOR ROOF SECTION DETAIL - CMU 3" = 1'-0"2 ELEVATOR JAMB DETAIL - CMU 3" = 1'-0"3 ELEVATOR HEAD DETAIL - CMU 1 1/2" = 1'-0"4 SILL SUPPORT - TWO SPEED DOORS - CMU 3/4" = 1'-0"5 ELEVATOR PIT SECTION - CMU DATE DESCRIPTION REV 48"30" 48"30"48"30"48"30"1. ALL CABINETS ARE ON 3" MODULE. 2. KITCHEN BASE CABINETS SHALL BE 24" DEEP AND WALL CABINETS SHALL BE 12" DEEP, UNLESS OTHERWISE NOTED. 3. MAXIMUM WIDTH OF CABINET DOORS NOT TO EXCEED 24". DOOR SWING AS INDICATED ON INTERIOR ELEVATIONS. 4. BATHROOM VANITY CABINETS SHALL BE 21" DEEP, UNLESS OTHERWISE NOTED. 5. ALL SHELVES TO HAVE HARD SURFACE EDGES. 6. FIELD VERIFY ALL DIMENSIONS. 7. DWR = DRAWERS H = HAMPER MC= MEDICINE CABINET 8. PROVIDE BLIND CABINET IN CORNERS OF ALL CABINETS. 9. CABINET SUB TO CONSTRUCT AND INSTALL ALL DESK COUNTERTOPS SO THAT THEY DO NOT DEFLECT UNDER LOADS OF 75 LBS. 10. ALL DESK COUNTERTOPS TO HAVE A SLIDE-OUT COMPUTER KEYBOARD TRAY MOUNTED TO BOTTOM OF COUNTERTOP. 11. REFER TO FINISH PACKAGES FOR CABINET, HARDWARE, COUNTERTOP FINISHES AND APPLIANCES. 12. PROVIDE SCRIBE MOLDING AND/OR FINISHED ENDS AS REQUIRED. 13. SUPPLIER TO FIELD VERIFY AREA OF WORK AFTER ROUGH FRAMING TO ASSURE FIT. THE CABINETS SHALL MATCH PLANS (NOTIFY ARCHITECT IN WRITING OF ANY DISCREPANCIES.) 14. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL PRIOR TO FABRICATIONS. 1. ALL FLOOR PLAN DIMENSIONS ARE TO FACE OF STUD FRAMING UNLESS NOTED OTHERWISE. 2. ALL REFLECTED CEILING PLAN DIMENSIONS ARE TO FACE OF STUD FRAMING UNLESS NOTED OTHERWISE. 3. ALL ANGLED WALLS ARE 45 DEGREES UNLESS NOTED OTHERWISE 4. REFER TO STRUCTURAL DRAWINGS FOR SHEAR WALL LOCATIONS. 5. REFERENCE BUILDING PLAN WITH ELEVATIONS TO COORDINATE WINDOW LOCATION. PARTICULAR CONDITIONS MAY EXIST. NOTIFY ARCHITECT IN WRITING WITH QUESTIONS PRIOR TO COMMENCEMENT OF CONSTRUCTION. 6. DOOR LOCATIONS NOT DIMENSIONED SHALL BE LOCATED AT MIDPOINT OF ROOM OR 4" CLEAR FROM ADJACENT WALL CORNER, TYPICAL. 7. ALL PLUMBING WALLS SHALL BE FRAMED WITH 2X6 STUDS, REFER TO PLANS FOR LOCATIONS. 8. CONTRACTOR TO PROVIDE STENCIL LABELING ON ALL FIRE RATED WALLS (TYP. ALL WALLS) 9. ALL GYP. BD TO BE 5/8" TYPE "X". PROVIDE WATER-RESISTANT GYPSUM BOARD AT ALL WET LOCATIONS (KITCHEN/TOILET) BACKSPLASHES, TUB SURROUNDS AND LAUNDRY WET WALLS). 10. PROVIDE 2'-8" DEEP PLATFORM IN MECHANICAL CLOSET (3/4" PLYWOOD OVER 2X6 FRAMING @ 16" O.C.) WHERE WATER HEATER OCCURS. 11. CONTRACTOR TO VERIFY AND COORDINATE PLUMBING ROUGH-IN DIMENSIONS WITH PLUMBER. 12. FOR TYPICAL BATHTUB INSTALLATION, SEE DETAIL . 13. FRAMING CONTRACTOR SHALL PROVIDE BLOCKING FOR ALL CABINETS, CEILING FANS, AND BATH ACCESSORIES. INCLUDE BLOCKING FOR GRAB BARS AT ALL LOCATIONS. 14. SHADED AREAS INDICATE FURR DOWN BELOW THE 1 HR. RATED FLOOR/CEILING ASSEMBLY FOR MECHANICAL EQUIPMENT. OTHER FURR DOWN AREAS ARE INDICATED. 15. VENT DRYERS TO OUTSIDE. SEE MECHANICAL DRAWINGS. 16. MECHANICAL DUCTWORK TO BE SEPARATED FROM ELECTRICAL PANELS. 17. CONTRACTOR TO COORDINATE RECESSED LIGHTING WITH MECHANICAL DUCT LOCATIONS. 18. ALL OUTLETS @ KITCHEN SINK & BATH LAVATORY COUNTER TO BE GFCI. 19. PROVIDE (1) 5 LB ABC FIRE EXTINGUISHER @ KITCHEN CABINET RANGE, TYP. 20. SMOKE DETECTORS SHALL NOT BE PLACED IN FRONT OF EXHAUST GRILLS. 21. SMOKE DETECTORS SHALL BE CONTINUOUSLY POWERED BY BUILDING ELECTRICAL SYSTEM AND INSTALLED IN ACCORDANCE WITH NFPA 101, 7-6.29 AND NFPA 74 W/ BATTERY BACK UP. 22. QUICK RESPONSE SPRINKLER SYSTEM TO BE PROVIDED THROUGHOUT, EXACT DESIGN AND SPECIFICATIONS TO BE NFPA 13 SUBMITTED BY CONTRACTOR TO ARCHITECT FOR SHOP DRAWING APPROVAL 23. INSPECT, REPAIR, AND PREPARE FLOORS AS REQUIRED TO PROVIDE A SATISFACTORY SUB-FLOOR FOR FLOOR FINISH MATERIALS. SATISFACTORY SUB-FLOOR IS DEFINED AS A SURFACE THAT IS FREE FROM CRACKS, HOLES, RIDGES, COATINGS, OR DEFECTS THAT WOULD PREVENT ADHESIVE BOND OR IMPAIR PERFORMANCE OR APPEARANCE OF FINISHED MATERIALS. 24. SEE FINISH SCHEDULES FOR ACTUAL FLOOR FINISH MATERIALS. FLOOR DEMARCATION LINES ON PLANS ARE FOR REFERENCE WHEN MATERIALS ARE TO DIFFER. 25. CONTRACTOR TO COORDINATE WITH CABINET MANUFACTURER FOR EXACT LOCATIONS OF KITCHEN EQUIPMENT AND FIXTURES. CONTRACTOR TO REVIEW PLUMBING, ELECTRICAL, AND FINISH LOCATIONS WITH CABINET DESIGN. 26. ALL SHELVING IN CLOSETS, LAUNDRY ROOMS, AND LINEN CLOSETS TO BE VENTILATED W/ OPEN WIRE SHELVING, PROVIDED AND MOUNTED IN ACCORDANCE WITH SHELVING PROFILES ON A3-00. 27. ALL SHELVING IN PANTRY CLOSETS TO BE "CLOSET MESH" VENTILATED WIRE SHELVING SYSTEM, PROVIDED AND MOUNTED IN ACCORDANCE WITH SHELVING PROFILES ON A3-00 28. PROVIDE 2" FAUX WOOD BLINDS AT ALL APARTMENT FRENCH DOORS AND WINDOWS. 29. MEZZANINE WINDOWS DO NOT RECEIVE MINI BLINDS. 1. INTERIOR ELEVATIONS ARE DRAWN TO FACE OF INTERIOR FINISH, U.N.O. 2.BATHROOM ACCESSORIES ARE TO BE MOUNTED AT THE FOLLOWING HEIGHTS. A. PROVIDE TOILET PAPER HOLDER ON WALL ADJACENT TO WATER CLOSET, TYPICAL ( 2'-0" A.F.F. TO CENTER). B. PROVIDE 18" TOWEL BAR, TYPICAL (4'-2" A.F.F. TO CENTER) C. PROVIDE CERAMIC TOWEL BAR OPPOSITE WET WALL AT BATHTUB, TYPICAL (4'-0" A.F.F. +/-TO CENTER) D. PROVIDE CERAMIC SOAP DISH, CENTERED ON BATHTUB SIDEWALL, TYPICAL (2'-2" A.F.F. TO CENTER) E. SHOWER HEAD SHALL BE MOUNTED AT 6'-6" A.F.F. F. SHOWER CURTAIN ROD TO BE AT 6'-8" A.F.F. TO CENTER. G. TILE TUB SURROUND SHALL EXTEND 5'-0" ABOVE RIM OF BATHTUB (6'-4" A.F.F.). 3.WALL MOUNTED LIGHT FIXTURES SHALL BE LOCATED PER ARCHITECT. 4.REFER TO ENLARGED UNIT PLANS FOR MILLWORK ELEVATIONS. UNIT PLAN NOTES UNIT ELEVATION NOTES CABINET NOTES TOILET TUB / SHOWERBATH VANITY 3' - 6" MAX. TOWEL BAR ABOVE TOILET AT 60" A.F.F. OTHERWISE AT 50" T.P. AT 24" A.F.F.7' - 6" A.F.F. TO CENTER LINE OF SHOWER ARM1' - 8"4' - 0" TO SHELF / NICHESOFFIT HEIGHT8' - 6"OF MIRROR7' - 0" TO TOP44" H. MIRROR 4" BACKSPLASH, TYP. INSTALL SO THAT TOP OF COUNTER IS AT 34" MAX. A.F.F., TYP. WOOD BASE BASE OF DESIGN OF NICHE IS TILE REDI MODEL RN1620S-BI EQ 1' - 4"EQ 6"WHEN PROVIDED ABOVE TOILET ON UNIT PLANS TUB TP SHOWER HEAD AND CONTROLS TO BE CENTERED ON TUB 2' - 6"4' - 0" TO SHELFEQ EQ EQ EQ EQ EQ TILE TO BE CENTERED ON SHOWER HEAD AND CONTROLS A.F.F. TO CENTER LINE OF CURTAIN RODMANUF.VERIFY WITHOF TOWEL BAR5' - 0" A.F.F. TO CENTERLINESOAP SHELF ON OPPOSITE WALL FROM SHOWER HEAD TYP. UNIT DOOR CENTERED DOOR PLACEMENT EQ EQ VARIES0' - 4" VARIES SEE UNIT PLANS TYP. UNIT DOOR OFFSET 0' - 6" U1 2' - 0" CORRIDOR UNIT TYP. UNIT ENTRY DOOR CABINETRY @ RANGE KITCHEN ISLAND TYPICAL2' - 3"1' - 3"4' - 6"RECEPTACLE IN CABINET MICROWAVE RANGE 3' - 6"1' - 6"3' - 0"FULL TILE BACKSPLASH 3' - 0"0' - 10"0' - 1"3' - 0"KITCHEN CABINETRY PROFILES @ TYPICAL UNITS FULL TILE BACKSPLASH CABINET LIGHT, ADD ALTERNATE 1' - 6"TO BOTTOM OF PENDANT LIGHT FIXTURECABINETRY TAG LEGEND VS48_4 FIRST POSITION •B = BASE CABINET •DB = DRAWER BANK •FP = FILLER PANEL •L = LINEN CLOSET •P = PANTRY •SB = SINK BASE CABINET •VS = VANITY SINGLE SINK •VD = VANITY DOUBLE SINK •W = WALL CABINET THIRD POSITION IF APPLICABLE •_ = WIDTH OF DRAWERS •- = DEPTH SECOND POSITION •WIDTH •WIDTH & HEIGHT W3624-24 NOTE: DIMENSIONS SHOWN ARE IN INCHES TYPICAL 3' - 0"1' - 10"2' - 10"FULL TILE BACKSPLASH CABINET LIGHT, ADD ALTERNATE KITCHEN ISLAND3' - 2"0' - 10"0' - 1"2' - 10"TO BOTTOM OF PENDANT LIGHT FIXTURE1' - 6"3' - 4"2' - 10"RECEPTACLE IN CABINET HOOD RANGE FULL TILE BACKSPLASH 2' - 10"CABINETRY @ RANGE KITCHEN CABINETRY PROFILES @ TYPE A UNITS 8' - 0"7' - 8"7' - 8"TYP. TOP LOAD WASHER AND FRONT LOAD DRYER CLEAR FLOOR SPACE REQUIREMENTS @ WASHER AND DRYER TYP. FRONT LOAD WASHER AND DRYER EQ EQ VARIESEQ EQ TYP. STACK LAUNDRYVARIES VARIES / -5 SHELVES CLOSET -1R/1S CLOSET -2R/2S1' - 1"1' - 1"1' - 1"1' - 1"1' - 8"3' - 0"SHELF 6' - 0"LAUNDRY -1 SHELF5' - 0"SHELF SHELVING PROFILES @ TYPICAL UNITS 6' - 0"B C D E A 1' - 4" 1' - 0". CLOSET -1R/1S @ H.C. UNITS4' - 0"D @ TYPE A UNITS BATH VANITY @ TYPE A UNITSOF MIRROR40" MAX TO BOTTOMBATHROOM PROFILES REFLECTING SURFACE3' - 4" TO BOTTOM OFTUB / SHOWER -TYPE B UNIT GRAB BAR LOCATIONS CONTROL WALLBACK WALL 9"-12"24" - 27" 36" MIN. GRAB BAR BLOCKING 18" MIN.69" MIN.9"-12" TUB / SHOWER -TYPE B UNIT GRAB BAR LOCATIONS HEAD WALL8" - 10" ABOVE TUB RIM.12" MAX.24" MAX. GRAB BAR BLOCKING GRAB BARS TO BE INSTALLED IN ALL SHOWERS AND TUB/SHOWER COMBINATIONS, PER 2018 NFPA 101 (LIFE SAFETY), SECTION 24.2.8 INSTALL VERTICAL GRAB BAR ON EITHER CONTROL WALL OR HEAD WALL. GRAB BAR IS NOT REQUIRED ON BOTH WALLS. INSTALL ON SIDE THAT IS LEAST OBSTRUCTIVE FOR ENTRY AND EGRESS. WHEN PROVIDED ABOVE TOILET ON UNIT PLANS SHOWER TP SHOWER HEAD AND CONTROLS TO BE CENTERED ON SHOWER PAN 2' - 6"4' - 0" TO SHELFEQ EQ EQ EQ EQ EQ TILE TO BE CENTERED ON SHOWER HEAD AND CONTROLS OF SHOWER ARM6' - 8" A.F.F. TO CENTER LINE OF TOWEL BAR5' - 0" A.F.F. TO CENTERLINECORNER SOAP SHELF ON OPPOSITE WALL FROM SHOWER HEAD HEAD WALL 9"-12"36" - 39" 24" MIN. GRAB BAR BLOCKING 30" MIN.69" MIN.9"-12" SHOWER -TYPE B UNIT GRAB BAR LOCATIONS INSTALL VERTICAL GRAB BAR ON EITHER CONTROL WALL OR HEAD WALL. GRAB BAR IS NOT REQUIRED ON BOTH WALLS. INSTALL ON SIDE THAT IS LEAST OBSTRUCTIVE FOR ENTRY AND EGRESS. CONTROL WALL SHOWER BATHROOM PROFILES 7' - 0" TO TOP OF GLASSREFER TO UNIT PLANS CEILING HEIGHTVARIES3' - 3"6' - 8" A.F.F. TO CENTER LINE OF SHOWER ARM4' - 0" TO SHELF CORNER SOAP SHELF ON OPPOSITE WALL FROM SHOWER HEAD C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 10:57:08 AMC:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.00 2247601 UNIT NOTES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 48"30"48"30"48"30"48"30"48"30"48"30"48"30"48"30"48"30"48"30"48"30"48"30"3' - 6"1' - 6"3' - 0"W3024 W09 W3042 W24 W3624W09 11' - 6" B09 B09 B30 7 5 6A21 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36" W3624 W24 W3042 W09 W3024 W09 3' - 6"1' - 6"3' - 0"P1896 B09 B09B30 6A 5 21 7 13' - 0" W3624 W09 W3024 W09 W3042 W21 W21 3' - 6"1' - 6"3' - 0"14' - 3" B30 B18B09B09L1596 6A 7 21 5 W24 W3024 W21 3' - 0"1' - 6"3' - 6"6' - 3" 7 B12 B21 W3624 W3342W24W3042 B30 B21P1896 5 6A 21 3 11' - 9" A04.01 4 8' - 6"3' - 0" 7 21 6A5 A04.01 2 1' - 6"3' - 0"8' - 7" 3 6A 5 21 7 A04.01 6 1' - 3"3' - 0"10' - 0" ISLAND LOCATION VARIES - SEE UNIT PLAN3'-6" MINIMUM3' - 6"3 6A 7 21 5 A04.01 10 9 8' - 9 1/4"3' - 0"1' - 6" 73'-6" MINIMUM3' - 6"3 6A 21 7 5 3' - 6"4' - 9"3' - 0"4' - 6" B21 B21 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 10:57:13 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.01 2247601 TYPICAL KITCHEN ELEVATIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/2" = 1'-0"4 KITCHEN 02 1/2" = 1'-0"2 KITCHEN 01 1/2" = 1'-0"6 KITCHEN 03 1/2" = 1'-0"10 KITCHEN 04 - CORNER 2 1/2" = 1'-0"9 KITCHEN 04 - CORNER 1 1/2" = 1'-0"3 KITCHEN 02 1/2" = 1'-0"1 KITCHEN 01 1/2" = 1'-0"5 KITCHEN 03 1/2" = 1'-0"8 KITCHEN 04 1/2" = 1'-0"7 TYPICAL KITCHEN ISLAND DATE DESCRIPTION REV UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36" 28 25 23 27 18" MIN. VSDB45_4 TYP34"45" 9C 29 31 291318 VSDB72_3 27 23 23 28 25 6' - 0"2' - 10"VSDB72_3 2323 27 28 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 10:57:17 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.02 2247601 TYPICAL BATH ELEVATIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/2" = 1'-0"1 BATH VANITY TYPE I - ELEVATION 1/2" = 1'-0"5 BATH - TUB/SHOWER ELEVATION 1/2" = 1'-0"2 BATH VANITY TYPE II - ELEVATION 1/2" = 1'-0"3 BATH VANITY TYPE III - ELEVATION 1/2" = 1'-0"6 BATH - SHOWER ELEVATION 1/2" = 1'-0"4 BATH VANITY - ADA DATE DESCRIPTION REV 48"56"9'-0" x 10'-10" BEDROOM 6'-11" x 14'-0" KITCHEN 10'-11" x 8'-9" LIVING 5'-5" x 8'-10" DINING 7'-7" x 8'-3" BATHROOM 5'-0" x 8'-3" ENTRY48"30"48"30"48"30"48"30"48"30"48"56"5' - 6"15' - 3 183/256"1' - 4 3/16" A04.01 4 A04.02 1 A04.02 5 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com NEW UNIT 11/30/2022 10:57:31 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.04 2247601 S2 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT S2 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT S2 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - S2 UNIT NAME AVERAGE UNIT AREA COUNT UNIT S2 610.96 SF 9 9 1/4" = 1'-0"3 UNIT S2 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56"11'-5" x 9'-11" BEDROOM 6'-0" x 5'-9" ENTRY 7'-3" x 8'-1" WIC 8'-4" x 16'-0" KITCHEN 11'-3" x 9'-11" LIVING 10'-10" x 6'-0" BATHROOM48"56"UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36" 11' - 9"10' - 9"6"5' - 6"A04.02 3 A04.025 A04.01 2 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 10:57:44 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.05 2247601 S3 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCLEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 1/4" = 1'-0"1 UNIT S3 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT S3 REFLECTED CEILING PLAN 1/4" = 1'-0"4 UNIT S3 TAG PLAN DATE DESCRIPTION REV UNIT COUNT - S3 UNIT NAME AVERAGE UNIT AREA COUNT UNIT S3 537.71 SF 4 4 60"66" 11'-5" x 9'-2" BEDROOM 8'-0" x 15'-11" KITCHEN 7'-3" x 6'-1" WIC 8'-5" x 8'-11" BATHROOM 5'-0" x 4'-11" ENTRY 10'-5" x 4'-10" BALCONY 11'-3" x 9'-0" LIVING ROOM 60"66" A04.02 4 A04.02 5 A04.012 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com NEW UNIT 11/30/2022 10:57:58 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.06 2247601 S3_TYPE A UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT S3 TYPE A CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT S3 TYPE A TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - S3 UNIT NAME AVERAGE UNIT AREA COUNT UNIT S3 537.71 SF 4 4 1/4" = 1'-0"3 UNIT S3_TYPE A REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56"48"30"12'-10" x 12'-3" BEDROOM 8'-6" x 13'-1" KITCHEN 13'-2" x 10'-9" LIVING 9'-5" x 6'-0" BATHROOM 5'-6" x 5'-5" ENTRY 9'-9" x 6'-9" WIC 48"56"48"30"UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36" 2 5 ' - 5 2 3 9 /2 5 6 "22' - 3"A04.02 1 A04.025 A04.01 27 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com NEW UNIT 11/30/2022 10:58:12 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.07 2247601 S4 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCLEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 1/4" = 1'-0"1 UNIT S4 CONSTRUCTION PLAN 1/4" = 1'-0"3 UNIT S4 REFLECTED CEILING PLAN 1/4" = 1'-0"2 UNIT S4 TAG PLAN DATE DESCRIPTION REV UNIT COUNT - S4 UNIT NAME AVERAGE UNIT AREA COUNT UNIT S4 626.63 SF 5 5 48"56" 11'-2" x 10'-9" BEDROOM 10'-0" x 13'-2" KITCHEN 12'-2" x 11'-2" LIVING 7'-5" x 7'-0" WIC 9'-6" x 7'-4" DINING 8'-5" x 9'-0" BATHROOM 10'-9" x 5'-0" BALCONY 48"30"48"30"48"30"48"30"48"30"48"56"3' - 6"11' - 11 1/2"1' - 4 1/2"10' - 9"11"5' - 6"A04.02 2A04.025 A04.01 2 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com LOSO UNIT 11/30/2022 10:58:25 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.08 2247601 A1 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT A1 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT A1 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - A1 UNIT NAME AVERAGE UNIT AREA COUNT UNIT A1 700.69 SF 81 81 1/4" = 1'-0"3 UNIT A1 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56" 10'-9" x 12'-4" BEDROOM 8'-6" x 13'-0" KITCHEN 12'-2" x 12'-8" LIVING 8'-6" x 9'-0" WIC 7'-3" x 6'-0" DINING 8'-4" x 9'-1" BATHROOM 5'-11" x 5'-6" ENTRY 10'-9" x 5'-0" BALCONY 48"30"48"30"48"30"48"30"48"30"48"56"5' - 6"11"10' - 9"12' - 4" A04.02 2A04.025 A04.01 2 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com MODIFIED LOSO UNIT 11/30/2022 10:58:39 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.09 2247601 A2 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT A2 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT A2 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - A2 UNIT NAME AVERAGE UNIT AREA COUNT UNIT A2 704.35 SF 3 3 1/4" = 1'-0"3 UNIT A2 REFLECTED CEILING PLAN DATE DESCRIPTION REV 60"56" 10'-9" x 12'-4" BEDROOM 7'-10" x 13'-2" KITCHEN 12'-2" x 12'-8" LIVING 8'-6" x 7'-0" WIC 7'-0" x 6'-0" DINING 8'-4" x 11'-1" BATHROOM 5'-11" x 7'-5" ENTRY 10'-9" x 5'-0" BALCONY 48"30"48"30"48"30"48"30"48"30"60"56"5' - 6"11"10' - 9" A04.02 4 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com MODIFIED LOSO UNIT 11/30/2022 10:58:53 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.10 2247601 A2_TYPE A UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT A2 TYPE A CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT A2 TYPE A TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - A2_A UNIT NAME AVERAGE UNIT AREA COUNT 1/4" = 1'-0"3 UNIT A2 TYPE A REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56" 12'-11" x 10'-9" BEDROOM 11'-0" x 13'-0" KITCHEN 16'-3" x 12'-4" LIVING 9'-3" x 7'-0" WIC 11'-5" x 7'-0" DINING 10'-5" x 9'-0" BATHROOM 10'-9" x 5'-0" BALCONY 48"56" UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"3' - 6"11"10' - 9"1' - 4 1/2"17' - 5 1/2" A04.02 2A04.025 A04.012 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 10:59:06 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.11 2247601 A3 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCLEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 1/4" = 1'-0"1 UNIT A3 CONSTRUCTION PLAN 1/4" = 1'-0"3 UNIT A3 REFLECTED CEILING PLAN 1/4" = 1'-0"2 UNIT A3 TAG PLAN UNIT COUNT - A3 UNIT NAME AVERAGE UNIT AREA COUNT UNIT A3 865.15 SF 12 12 DATE DESCRIPTION REV 48"56"48"30"48"30"17'-9" x 12'-5" BEDROOM 20'-4" x 10'-0" KITCHEN 13'-7" x 15'-3" LIVING 9'-1" x 6'-1" WIC 9'-6" x 7'-4" DINING 8'-3" x 9'-4" BATHROOM 10'-9" x 5'-0"BALCONY18'-3" x 4'-6" ENTRY48"56" UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36" 31 ' - 1 1/2"33' - 6"A04.022A04.02 5 A04.01 6 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 10:59:20 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.12 2247601 A4 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCLEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 1/4" = 1'-0"1 UNIT A4 REFLECTED CEILING PLAN 1/4" = 1'-0"2 UNIT A4 CONSTRUCTION PLAN 1/4" = 1'-0"3 UNIT A4 TAG PLAN DATE DESCRIPTION REV UNIT COUNT - A4 UNIT NAME AVERAGE UNIT AREA COUNT UNIT A4 964.86 SF 8 8 48"56"11'-0" x 12'-6" BEDROOM 8'-0" x 14'-2" KITCHEN 7'-3" x 8'-5" WIC 10'-10" x 6'-0" BATHROOM 5'-0" x 5'-10" ENTRY 10'-9" x 5'-0" BALCONY 11'-11" x 11'-10" LIVING ROOM 48"30"48"30"48"30" 48"30"48"56"5' - 6"1' - 0"10' - 9"12' - 3" A04.02 3 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com LOSO UNIT 11/30/2022 10:59:34 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.13 2247601 A5 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT A5 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT A5 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - A5 UNIT NAME AVERAGE UNIT AREA COUNT UNIT A5 678.05 SF 10 10 1/4" = 1'-0"3 UNIT A5 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56"12'-6" x 10'-11" BEDROOM 13'-2" x 8'-5" KITCHEN 16'-3" x 11'-3" LIVING 8'-6" x 6'-0" DINING 9'-5" x 5'-9" BATHROOM 8'-8" x 7'-5" WIC 6'-5" x 5'-10" ENTRY 10'-9" x 5'-0" BALCONY 48"30"48"30"48"30"48"30"48"56"5' - 6"11' - 9 1/2"18' - 2 1/2" A04.02 1 A04.02 5 A04.01 2 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com MODIFIED LOSO UNIT 11/30/2022 10:59:47 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.14 2247601 A6 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT A6 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT A6 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - A6 UNIT NAME AVERAGE UNIT AREA COUNT UNIT A6 730.02 SF 30 30 DATE DESCRIPTION REV 48"56" 10'-11" x 13'-2" BEDROOM 10'-4" x 18'-10" KITCHEN 10'-6" x 12'-8" LIVING 7'-3" x 8'-1" WIC 7'-3" x 6'-0" DINING 8'-4" x 9'-1" BATHROOM 6'-2" x 5'-3" ENTRY 10'-9" x 5'-0" BALCONY 48"30"48"30"48"30"48"30"48"56"5' - 0"32' - 6"3"10' - 9"11' - 4" A04.02 2A04.025 A04.012 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com NEW UNIT 11/30/2022 11:00:00 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.15 2247601 A7 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT A7 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT A7 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - A7 UNIT NAME AVERAGE UNIT AREA COUNT UNIT A7 717.54 SF 15 15 1/4" = 1'-0"3 UNIT A7 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56" 10'-7" x 10'-6" BEDROOM 6'-2" x 16'-2" KITCHEN 7'-9" x 12'-11" LIVING 7'-1" x 7'-3" WIC 12'-5" x 5'-0" DINING 8'-4" x 9'-1" BATHROOM 5'-9" x 8'-11" ENTRY 48"30"48"30"48"30"48"30"48"30"48"56" 3' - 11 1/2"10' - 9"9 1/2" A04.01 2 A04.02 2 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com LOSO UNIT 11/30/2022 11:00:14 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.16 2247601 AU1 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT AU1 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT AU1 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - AU1 UNIT NAME AVERAGE UNIT AREA COUNT UNIT AU1 667.80 SF 12 12 1/4" = 1'-0"3 UNIT AU1 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56" 9'-11" x 13'-4" BEDROOM 8'-1" x 13'-1" KITCHEN 12'-0" x 13'-10" LIVING 9'-11" x 6'-6" WIC 11'-7" x 6'-0" DINING 7'-6" x 9'-8" BATHROOM 5'-6" x 7'-10" ENTRY 10'-10" x 13'-5" BEDROOM 8'-11" x 7'-8" WIC 9'-11" x 7'-0" BATHROOM 10'-9" x 5'-0" BALCONY 48"30" 48"30"48"30"48"30"48"30"48"30"48"56" UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36" 12' - 2"10' - 9"1' - 4"10' - 3"3' - 6"A04.02 6A04.022 A04.02 1 A04.02 5 A04.012 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com LOSO UNIT 11/30/2022 11:00:27 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.18 2247601 BA1 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT BA1 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT BA1 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - BA1 UNIT NAME AVERAGE UNIT AREA COUNT UNIT BA1 <varies> 19 19 1/4" = 1'-0"3 UNIT BA1 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56"48"56"13'-4" x 14'-8" BEDROOM 8'-3" x 13'-1" KITCHEN 13'-6" x 14'-10" LIVING 5'-6" x 7'-0" WIC 7'-3" x 6'-0" DINING 5'-6" x 10'-3" BATHROOM 6'-2" x 6'-1" ENTRY 14'-10" x 11'-1" BEDROOM 5'-11" x 5'-8" WIC 11'-7" x 5'-8" BATHROOM14'-0" x 10'-6"BALCONY48"30"48"30"48"30"48"30"48"30"48"56"48"56"A04.02 2 A04.02 5 A04.01 2 A04.02 1A04.02 5 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com LOSO UNIT 11/30/2022 11:00:41 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.20 2247601 B1 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT B1 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT B1 TAG PLAN UNIT COUNT - B1 UNIT NAME AVERAGE UNIT AREA COUNT UNIT B1 1,036.45 SF 40 40 1/4" = 1'-0"3 UNIT B1 REFLECTED CEILING PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 DATE DESCRIPTION REV 48"56"48"56"48"30"11'-9" x 11'-8" BEDROOM 9'-2" x 14'-7" KITCHEN 12'-0" x 12'-10" LIVING 5'-2" x 4'-5" WIC 9'-5" x 7'-2" DINING 6'-0" x 9'-3" BATHROOM 7'-4" x 10'-0" BATHROOM 11'-0" x 12'-0" BEDROOM 4'-10" x 9'-4" WIC 8'-3" x 8'-0" ENTRY 10'-9" x 5'-0" BALCONY 48"30"48"30"48"30"48"30"48"30"48"30"48"56"48"56"48"30"TRANSOM WINDOW IN B2 UNITS; B2.1 UNITS HAVE WINDOW TO EXTERIOR5' - 6"11"10' - 9"13' - 0" 24' - 8" A04.016 A04.02 1A04.02 5 A04.02 2A04.026 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com LOSO UNIT 11/30/2022 11:00:54 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.21 2247601 B2 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT B2 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT B2 TAG PLAN UNIT COUNT - B2 UNIT NAME AVERAGE UNIT AREA COUNT UNIT B2 1,063.64 SF 33 UNIT B2.1 1,024.98 SF 5 38 1/4" = 1'-0"3 UNIT B2 REFLECTED CEILING PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 DATE DESCRIPTION REV 30"48"48"56"30"48"48"56"12'-6" x 10'-10" BEDROOM 13'-0" x 9'-8" KITCHEN 10'-1" x 16'-2" LIVING 5'-9" x 6'-0" WIC 7'-8" x 11'-6" DINING 10'-1" x 5'-9" BATHROOM 10'-1" x 5'-9" BATHROOM 10'-1" x 12'-3" BEDROOM 8'-7" x 7'-5" WIC 7'-3" x 5'-9" ENTRY 10'-9" x 5'-0" BALCONY 30"48"48"56"30"48"48"56"5' - 6"10' - 9"19' - 2" A04.02 1 A04.02 5A04.02 1 A04.025 A04.01 2 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com LOSO UNIT 11/30/2022 11:01:08 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.22 2247601 B3 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT B3 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT B3 TAG PLAN LEVEL 3, 4, & 5 LEVEL 9 & 10 LEVEL 6 & 7 LEVEL 8 UNIT COUNT - B3 UNIT NAME AVERAGE UNIT AREA COUNT UNIT B3 1,026.09 SF 6 6 1/4" = 1'-0"4 UNIT B3 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56"48"56"10'-5" x 13'-4" BEDROOM13'-1" x 12'-11" LIVING 6'-5" x 6'-0" WIC 12'-8" x 8'-8" DINING 9'-5" x 5'-11" BATHROOM 8'-0" x 8'-9" BATHROOM 7'-1" x 7'-8" WIC 13'-4" x 11'-1" KITCHEN 6'-1" x 8'-9" ENTRY 10'-3" x 11'-0" BEDROOM 10'-9" x 5'-0" BALCONY 48"56"48"56"5' - 6"11"10' - 9"25' - 4" A04.0110 9 7 A04.02 1 A04.025 A04.02 2A04.026 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com LOSO UNIT 11/30/2022 11:01:21 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.24 2247601 B4 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT B4 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT B4 TAG PLAN UNIT COUNT - B4 UNIT NAME AVERAGE UNIT AREA COUNT LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 1/4" = 1'-0"3 UNIT B4 REFLECTED CEILING PLAN DATE DESCRIPTION REV 30"48"48"56"48"56" 10'-11" x 15'-6" BEDROOM 10'-11" x 12'-1" LIVING 8'-6" x 5'-3" WIC 8'-6" x 12'-1" DINING 8'-6" x 9'-3" BATHROOM 6'-9" x 9'-0" BATHROOM 3'-7" x 6'-1" WIC 19'-0" x 8'-2" KITCHEN 12'-8" x 6'-11" ENTRY 11'-6" x 13'-6" BEDROOM 5'-0" x 10'-9" BALCONY 48"30"48"30"48"30"30"48"48"56"48"56"1' - 9"10' - 9"25' - 0"5' - 6"14' - 1 1/2"5' - 11"9' - 4"2' - 5"31' - 8" A04.02 1 A04.02 5 A04.022A04.02 6 A04.01 6 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com NEW UNIT 11/30/2022 11:01:48 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.27 2247601 B6 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT B6 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT B6 TAG PLAN UNIT COUNT - B6 UNIT NAME AVERAGE UNIT AREA COUNT UNIT B6 1,131.57 SF 18 18 LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 1/4" = 1'-0"3 UNIT B6 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56" 11'-0" x 12'-6" BEDROOM 12'-2" x 13'-1" KITCHEN 12'-4" x 10'-0" LIVING 5'-0" x 5'-8" WIC 7'-4" x 5'-5" DINING 5'-7" x 11'-9" BATHROOM 8'-9" x 7'-7" ENTRY 11'-0" x 10'-7" DEN 10'-9" x 5'-0" BALCONY 48"30"48"30"48"30"48"30"5'-0" x 5'-8" WIC48"56" 11"10' - 9"12' - 10"5' - 6"A04.012 A04.02 2A04.02 5 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com MODIFIED LOSO UNIT 11/30/2022 11:02:01 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.28 2247601 AD2 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT AD2 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT AD2 TAG PLAN LEVEL 3, 4, & 5 LEVEL 6 & 7LEVEL 8 LEVEL 9 & 10 UNIT COUNT - AD2 UNIT NAME AVERAGE UNIT AREA COUNT UNIT AD2 863.63 SF 24 24 1/4" = 1'-0"4 UNIT AD2 REFLECTED CEILING PLAN DATE DESCRIPTION REV 48"56"48"56" 11'-4" x 14'-2" BEDROOM 17'-6" x 8'-8" KITCHEN 12'-5" x 13'-11" LIVING 7'-0" x 7'-0" WIC 14'-11" x 7'-6" DINING 9'-1" x 8'-6" BATHROOM 7'-6" x 6'-11" ENTRY 10'-5" x 13'-6" BEDROOM 9'-1" x 5'-3" WIC 6'-7" x 9'-4" BATHROOM 48"30"48"30"48"30"48"30"48"30" 48"56"48"56"1' - 3"10' - 9"19' - 6"31' - 6"5' - 6"36' - 6" 42' - 0" A04.021A04.02 5 A04.02 2 A04.02 6 A04.01 6 UNIT LEGEND 1 HVAC UNIT/WATER HEATER SEE MECHANICAL DWGS 2 WASHER 3 PANTRY CABINET 4 WASHER & DRYER - STACKABLE 5 DISHWASHER 6A 22 CU.FT. REFRIGERATOR 7 RANGE W/ MICROWAVE ABOVE & VENTLESS HOOD 8 DRYER 9A 36" x 60" GARDEN TUB 10 THERMOSTAT CONTROL 11 ELECTRICAL PANEL 12 SOAP DISH 13 SHOWER CURTAIN ROD 14 PEDESTAL SINK 15 FOLDING GRAB BAR 16 MOVEABLE ISLAND W/ COUNTERTOP ON ALUMINIUM CASTERS 17A 36" x 36" 17B 42" x 34" 21 SINGLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 22 DOUBLE STAINLESS STEEL KIT. SINK W/ DISPOSAL 23 SINGLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 24 DOUBLE BOWL & OVERFLOW COUNTERTOP - GRANITE UNDERMOUNT 25 TOILET PAPER HOLDER 26 TOWEL BAR (24") 27 MIRROR 28 ELONGATED TOILET 29 SHOWER HEAD 30 SHOWER & TUB FAUCET 31 TUB FAUCET 32 EXHAUST 33 CORNER GRAB BAR 34 DOUBLE OVEN 35 TILE BACKSPLASH 6B 25 CU.FT. REFRIGERATOR 9B 42" x 60" GARDEN TUB 9C 30" x 60" GARDEN TUB F COMPUTER DESK WITH (1) WOOD SHELF ABOVE AND GRANITE COUNTERTOP 17 SHOWER PAN WITH ACRYLIC BASE 18 TILE SHOWER SURROUND, SEE 7/A3-00 19 ROBE HOOK 20 TOWEL RING UNIT SHELVING LEGEND A (1) 12" DEEP SHELF @ WASHER / DRYER B (5) 16" DEEP SHELVES C (5) 12" DEEP SHELVES D DOUBLE HANGING ROD & SHELF E HANGING ROD AND SHELF ACCESSIBILITY LEGEND 41 SINGLE BOWL STAINLESS STEEL SINK, WITH ADA FAUCET, PROVIDE PIPE WRAP BELOW, BASE CABINET TO BE REMOVABLE WITH FLOOR AND WALL FINISH BELOW, BOWL TO BE AT 34" MAX. HIGH A.F.F. 42 34" HIGH WORK SURFACE, MIN. 30" WIDE WITH FLOOR AND WALL FINISH BELOW, MIN. 27" KNEE HEIGHT CLEARANCE 43 SIDE BY SIDE REFRIGERATOR 44 RECIRCULATING EXHAUST HOOD WITH LIGHT, SWITCH FROM WALL ADJACENT TO STOVE 45 ALL IN ONE WASHER/ DRYER 46 ELONGATED ADA TOILET BOWL WITH SEAT HEIGHT AT 18" AND FLUSH VALVE ON OPEN SIDE OF WATER CLOSET 47 FUTURE GRAB BAR - SEE ELEVATIONS FOR SIZES 48 REMOVABLE BASE CABINET AT VANITY, PROVIDE FLOOR AND WALL FINISH BELOW, WRAP ALL PIPES 49 SHOWER HEAD WITH SLIDE BAR AND ADJUSTABLE HEIGHT HEAD 50 LOCATION OF FUTURE BATHING SEAT 51 ADA RANGE WITH CONTROLS ON FRONT OF RANGE 52 CLOSET SHELF AND ROD AT 48" MAX HEIGHT 53 ONE (1) WINDOW SHALL BE ACCESSIBLE W/ OPERABLE PARTS LOACTED AT 48" MAX HEIGHT 54 ADA DISHWASHER UNDER 34" HIGH COUNTER 1. REFER TO SHEET A4-00 FOR UNIT PLAN NOTES 2. ELECTRICAL OUTLETS SHALL NOT BE CUT INTO MIRROR 3. NOTE T INDICATES THERMOSTAT 4. REFER TO SHEET A4-00 FOR STANDARD ARCHWAY DETAIL 5. REFER TO "CD" SERIES FOR FAIR HOUSING CONSTRUCTION REQUIREMENTS. ALL UNITS TO RECEIVE BLOCKING AS SHOWN IN "CD" SERIES 6. CEILING FIXTURES NOT DIMENSIONED ARE TO BE CENTERED ON ROOM NOTES 55 ADA COMBINATION WASHER/DRYER 17C 42" x 42" 17D 60" x 34" 17E 60" x 36"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com NEW UNIT 11/30/2022 11:02:15 AM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA04.30 2247601 B10 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 UNIT B10 CONSTRUCTION PLAN 1/4" = 1'-0"2 UNIT B10 TAG PLAN UNIT COUNT - B10 UNIT NAME AVERAGE UNIT AREA COUNT 1/4" = 1'-0"3 UNIT B10 REFLECTED CEILING PLAN LEVEL 3, 4, & 5 LEVEL 9 & 10 LEVEL 6 & 7 LEVEL 8 DATE DESCRIPTION REV LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 2 A06.01 LOW ROOF F.F.E. = 745' -6" 3 A06.01 A05.03 9 1 A06.02 2 A00.13 3 A00.13 4 A00.13 4 A06.02 4' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"105' - 10"LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 1 A06.01 LOW ROOF F.F.E. = 745' -6" 3 A06.02 2 A06.02 1 A00.13 4' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"CORRUGATED METAL PANEL FIBER CEMENT PANEL FIBER CEMENT PANEL MODULAR FACE BRICK VENEER CAST IN PLACE CONCRETE FIBER CEMENT PANEL BALCONY RAILING W/ WIRE MESH BALCONY RAILING C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:15:23 PM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA05.01 2247601 OVERALL BUILDING ELEVATIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 OVERALL ELEVATION - WEST 1/16" = 1'-0"2 OVERALL ELEVATION - SOUTH DATE DESCRIPTION REV EXTERIOR FINISH KEY LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" 1 A06.01 LOW ROOF F.F.E. = 745' -6" 1 A00.13 9' - 3"9' - 3"9' - 3"9' - 3"11' - 6"10' - 8"10' - 8"10' - 8"4' - 0"LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" 3 A06.02 2 A06.02 A05.03 2 9' - 3"9' - 3"9' - 3"9' - 3"11' - 6"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"5' - 0"106' - 10"LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6"5' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LOW ROOF F.F.E. = 745' -6" 1 A06.02 4 A00.13 4 A06.02 5' - 0"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"85' - 6"CORRUGATED METAL PANEL FIBER CEMENT PANEL FIBER CEMENT PANEL MODULAR FACE BRICK VENEER CAST IN PLACE CONCRETE FIBER CEMENT PANEL BALCONY RAILING W/ WIRE MESH BALCONY RAILING C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:16:40 PM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA05.02 2247601 OVERALL BUILDING ELEVATIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 OVERALL ELEVATION - NORTH - PART 1 1/16" = 1'-0"2 OVERALL ELEVATION - NORTH - PART 2 1/16" = 1'-0"3 OVERALL ELEVATION EAST - PART 1 1/16" = 1'-0"4 OVERALL ELEVATION - EAST - PART 2 DATE DESCRIPTION REV EXTERIOR FINISH KEY LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 2 A06.01 LOW ROOF F.F.E. = 745' -6" 3 A00.13 4' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" 2 A06.02 10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 2 A06.01 LOW ROOF F.F.E. = 745' -6" 3 A00.13 LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" 3 A06.02 10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" 3 A06.01 2 A00.13 10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" 3 A06.02 10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"4' - 0"LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" 3 A06.01 2 A00.13 10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" 3 A06.01 2 A00.13 4' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 1 A06.01 LOW ROOF F.F.E. = 745' -6" 1 A00.13 10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"4' - 0"LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" 1 A06.01 LOW ROOF F.F.E. = 745' -6" 1 A00.13 1 A06.10 4' - 0"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 2:39:44 PM C:\Users\ahamilton\Documents\Revit\2247601_MCRT_Foundry_Option 5_ahamiltonBUUMR.rvtA05.03 2247601 COURTYARD ELEVATIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 COURTYARD A ELEVATION - EAST 1/16" = 1'-0"2 COURTYARD A ELEVATION - SOUTH 1/16" = 1'-0"3 COURTYARD A ELEVATION - WEST 1/16" = 1'-0"4 COURTYARD B ELEVATION - NORTH 1/16" = 1'-0"5 COURTYARD B ELEVATION - EAST 1/16" = 1'-0"6 COURTYARD B ELEVATION - SOUTH 1/16" = 1'-0"7 COURTYARD B ELEVATION - WEST 1/16" = 1'-0"9 PRIVATE TERRACES ELEVATION - EAST 1/16" = 1'-0"10 PRIVATE TERRACES ELEVATION - SOUTH 1/16" = 1'-0"8 PRIVATE TERRACES ELEVATION - NORTH DATE DESCRIPTION REV AGP BLDG 2 F.F.E. = 672' -2" AGP BLDG 1 F.F.E. = 690' -0" AGP BLDG 2 F.F.E. = 672' -2" AGP BLDG 1 F.F.E. = 690' -0" AGP BLDG 2 F.F.E. = 672' -2" AGP BLDG 1 F.F.E. = 690' -0" AGP BLDG 2 F.F.E. = 672' -2" AGP BLDG 1 F.F.E. = 690' -0" FIREWALL AVERAGE GRADE PLANE BUILDING 2 AVERAGE GRADE PLANE BUILDING 1 FIREWALL AVERAGE GRADE PLANE BUILDING 2 AVERAGE GRADE PLANE BUILDING 1 FIREWALL AVERAGE GRADE PLANE BUILDING 1 AVERAGE GRADE PLANE BUILDING 2 FIREWALL AVERAGE GRADE PLANE BUILDING 2 AVERAGE GRADE PLANE BUILDING 1 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:06 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA05.20 2247601 SITE AXON VIEWS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1 AXON - WEST CORNER2AXON - SOUTH CORNER 3 AXON - NORTH CORNER 4 AXON - EAST CORNER DATE DESCRIPTION REV LEVEL 1 F.F.E. = 665' -0" LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" LOW ROOF F.F.E. = 745' -6" AGP BLDG 2 F.F.E. = 672' -2" AGP BLDG 1 F.F.E. = 690' -0"8' - 2"76' - 10"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"102' - 6 1/2"19' - 5"10' - 11 1/2"74' - 0 1/2"81' - 2 1/2"LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"7' - 3"7' - 6"101' - 10"LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:11 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA06.01 2247601 BUILDING SECTIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"1 BUILDING SECTION 1 1/16" = 1'-0"2 BUILDING SECTION 2 1/16" = 1'-0"3 BUILDING SECTION 3 DATE DESCRIPTION REV LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"AGP BLDG 2 F.F.E. = 672' -2" AGP BLDG 1 F.F.E. = 690' -0" LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6"10' - 8"10' - 8"10' - 8"10' - 8"10' - 8"11' - 6"9' - 3"9' - 3"9' - 3"9' - 3"LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" LOW ROOF F.F.E. = 745' -6" LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" LOW ROOF F.F.E. = 745' -6"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 12:19:34 PM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA06.02 2247601 BUILDING SECTIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/16" = 1'-0"2 BUILDING SECTION 5 1/16" = 1'-0"3 BUILDING SECTION 61/16" = 1'-0"1 BUILDING SECTION 4 1/16" = 1'-0"4 BUILDING SECTION 8 DATE DESCRIPTION REV LEVEL 1 F.F.E. = 665' -0" LEVEL 2 F.F.E. = 674' -3" LEVEL 3 F.F.E. = 683' -6" LEVEL 4 F.F.E. = 692' -9" LEVEL 5 F.F.E. = 702' -0" LEVEL 6 F.F.E. = 713' -6" LEVEL 7 F.F.E. = 724' -2" LEVEL 8 F.F.E. = 734' -10" LEVEL 9 F.F.E. = 745' -6" LEVEL 10 F.F.E. = 756' -2" HIGH ROOF F.F.E. = 766' -10" LOW ROOF F.F.E. = 745' -6" A06.10 2 A06.10 3 A06.10 4 A06.10 5 7"7"10"1" / 12" 1" / 12" 1" / 12" LEVEL 4 F.F.E. = 692' -9" AGP BLDG 1 F.F.E. = 690' -0" LEVEL 5 F.F.E. = 702' -0"1 1/4"1 1/4"LEVEL 8 F.F.E. = 734' -10"1 1/4"1 1/4"LEVEL 9 F.F.E. = 745' -6" LOW ROOF F.F.E. = 745' -6"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:18 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA06.10 2247601 SECTION DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NC1/4" = 1'-0"1 BUILDING SECTION AT FIREWALL DATE DESCRIPTION REV 1 1/2" = 1'-0"2 FIRE WALL - CONCRETE PODIUM 1 1/2" = 1'-0"3 FIRE WALL - CONCRETE TO WOOD TRUSS TRANSITION 1 1/2" = 1'-0"4 FIRE WALL - WOOD TRUSSES 1 1/2" = 1'-0"5 FIRE WALL - LOW ROOF TERMINATION WINDOW SCHEDULE LEGEND 1' - 9"6' - 0"HEAD HEIGHT7' - 9"1' - 9"6' - 0"HEAD HEIGHT7' - 9"1' - 9"6' - 0"HEAD HEIGHT7' - 9"HEAD HEIGHT8' - 0"3' - 0"9' - 0"5' - 10 1/2"6' - 0"HEAD HEIGHT8' - 0"HEAD HEIGHT8' - 0"6' - 0"6' - 3"HEAD HEIGHT8' - 0"8' - 3"HEAD HEIGHT8' - 0"1' - 0"7' - 0"HEAD HEIGHT8' - 0"8' - 0" 2' - 0" W01 W02 W03 W04 W06 W07 W08 W09 W10 HEAD HEIGHT8' - 0"W05 3' - 0" F F F F F F F F F F F F F F F F F F F F C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:22 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA08.00 2247601 WINDOW SCHEDULE SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCWINDOW SCHEDULE TYPE WINDOW FRAME MANUFACTURER NOTES SIZE GLAZING MAT'L FINISHWIDTH HEIGHT W01 5' - 10 1/2" 6' - 0" VINYL GREY STERGIS SINGLE HUNG, EQUAL SASH, 2/2 Horizontal W02 5' - 10 1/2" 6' - 0" VINYL GREY STERGIS DOUBLE, SINGLE HUNG, EQUAL SASH, 2/2 Horizontal W03 9' - 0" 6' - 0" VINYL GREY STERGIS TRIPLE, SINGLE HUNG, EQUAL SASH, 2/2 Horizontal W04 3' - 0" 5' - 9 1/2" VINYL GREY STERGIS SINGLE HUNG / FIXED, EQUAL SASH W05 6' - 0" 5' - 9" VINYL GREY STERGIS DOUBLE, SINGLE HUNG / FIXED, EQUAL SASH, 2/2 Horizontal W06 6' - 0" 5' - 9" VINYL GREY STERGIS DOUBLE, SINGLE HUNG / FIXED, EQUAL SASH W07 6' - 3" 5' - 9 1/2" VINYL GREY STERGIS DOUBLE, SINGLE HUNG / FIXED, EQUAL SASH W08 2' - 8" 6' - 2 1/2" VINYL GREY STERGIS TRIPLE, SINGLE HUNG / FIXED, EQUAL SASH W09 2' - 8" 6' - 0" VINYL GREY STERGIS TRIPLE, SINGLE HUNG / FIXED, EQUAL SASH W10 2' - 0" 7' - 0" VINYL GREY STERGIS FIXED DATE DESCRIPTION REV 3' -0"000000 8' -3"000000 8' -0"000000 8' -0"000000 8' -0"000000 8' -0"000000 8' -0"000000 8' -0"000000 8' -0"000000 ALL OPERABLE WINDOWS SHALL HAVE 4" LIMITER PER CODE SECTION XXXX.XX 3' - 8"3' - 8"3' - 8" 11' - 0"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"5' - 0"1' - 3"10' - 0"16' - 3"SF-03 SF-04 9' - 6" 4' - 9"4' - 9"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"5' - 0"1' - 3"10' - 0"16' - 3"SF-01 SF-02 9' - 6" SF-05 SF-06 3' - 1"3' - 4"3' - 1"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"5' - 0"1' - 3"10' - 0"16' - 3"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"1' - 3"5' - 0"16' - 3"SF-07 SF-08 4' - 0"4' - 0"4' - 0" 12' - 0" 3' - 4"3' - 4"3' - 4" 10' - 0"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"1' - 3"5' - 0"16' - 3"SF-09 SF-10 SF-11 SF-12 3' - 4"3' - 4" 6' - 8"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"5' - 0"1' - 3"10' - 0"16' - 3"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"1' - 3"5' - 0"16' - 3"3' - 4"3' - 4"3' - 4" 10' - 0" SF-13 SF-14 2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"5' - 0"1' - 3"7' - 6"13' - 9"11' - 0" 3' - 8"3' - 8"3' - 8" SF-15 SF-16 2' - 6"2' - 6"3' - 8"3' - 8"3' - 8"5' - 0"SF-17 11' - 0" SF-18 3' - 4"3' - 4"3' - 4" 10' - 0"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"3' - 4"3' - 4"6' - 8"3' - 4"3' - 4" 20' - 0"2' - 6"2' - 6"2' - 6"2' - 6"2' - 6"12' - 6"SF-19 2' - 8 1/4"3' - 1 7/8"3' - 1 7/8" 9' - 0"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"1' - 6"3' - 0"14' - 6"SF-20 SF-21 EQ EQ EQ 10' - 8"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"1' - 6"3' - 0"14' - 6"SF-22 SF-23 3' - 4 3/4"3' - 2 1/2"3' - 4 3/4" 10' - 0"10' - 0"1' - 6"3' - 0"2' - 6"2' - 6"2' - 6"2' - 6"14' - 6"SF-24 SF-25 3' - 10 3/4"6' - 2 1/2"3' - 10 3/4" 14' - 0"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"1' - 6"3' - 0"14' - 6"SF-27 SF-26 2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"1' - 6"3' - 0"14' - 6"4' - 6"4' - 6" 9' - 0" SF-28 SF-29 4' - 6"4' - 6"4' - 6"4' - 6" 18' - 0"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"5' - 6"SF-30 3' - 4"3' - 4"3' - 4" 10' - 0"2' - 6"2' - 6"2' - 6"2' - 6"10' - 0"5' - 6"SF-31 17' - 6"2' - 6"2' - 6"2' - 6"7' - 6"8' - 0"SF-32 4' - 4 1/2"4' - 4 1/2"4' - 4 1/2"4' - 4 1/2" 17' - 0"2' - 6"2' - 6"5' - 0"10' - 6"SF-33 4' - 3"4' - 3"4' - 3"4' - 3" 17' - 2"2' - 0"14' - 3"SF-34 4' - 3 1/2"4' - 3 1/2"4' - 3 1/2"4' - 3 1/2"C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:30 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA08.20 2247601 STOREFRONT SCHEDULE SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV STOREFRONT SCHEDULE Storefront Number Length Height Manufacturer Comments SF-01 9' - 6" 5' - 0" SF-02 9' - 6" 10' - 0" SF-03 11' - 0" 5' - 0" SF-04 11' - 0" 10' - 0" SF-05 9' - 6" 5' - 0" SF-06 9' - 6" 10' - 0" SF-07 12' - 0" 5' - 0" SF-08 12' - 0" 10' - 0" SF-09 10' - 0" 5' - 0" SF-10 10' - 0" 10' - 0" SF-11 6' - 8" 5' - 0" SF-12 6' - 8" 10' - 0" SF-13 10' - 0" 5' - 0" SF-14 10' - 0" 10' - 0" SF-15 11' - 0" 5' - 0" SF-16 11' - 0" 7' - 6" SF-17 11' - 0" 5' - 0" SF-18 10' - 0" 10' - 0" SF-19 20' - 0" 12' - 6" SF-20 9' - 0" 3' - 0" SF-21 9' - 0" 10' - 0" SF-22 10' - 8" 3' - 0" SF-23 10' - 8" 10' - 0" SF-24 10' - 0" 3' - 0" SF-25 10' - 0" 10' - 0" SF-26 14' - 0" 3' - 0" SF-27 14' - 0" 10' - 0" SF-28 9' - 0" 3' - 0" SF-29 9' - 0" 10' - 0" SF-30 18' - 0" 10' - 0" SF-31 10' - 0" 10' - 0" SF-32 17' - 6" 7' - 6" SF-33 17' - 0" 5' - 0" SF-34 17' - 2" 2' - 0" SF-35 9' - 8" 8' - 0" SF-36 9' - 8" 10' - 0" SF-37 8' - 8" 8' - 0" SF-38 8' - 8" 10' - 0" SF-39 6' - 8" 8' - 0" SF-40 6' - 8" 10' - 0" SF-41 13' - 0" 8' - 0" SF-42 13' - 0" 10' - 0" SF-43 9' - 0" 8' - 0" SF-44 9' - 0" 10' - 0" SF-45 9' - 0" 8' - 0" SF-46 9' - 0" 10' - 0" SF-47 5' - 0" 8' - 0" SF-48 5' - 0" 10' - 0" LEVEL 1 F.F.E. = 665' - 0" LEVEL 2 F.F.E. = 674' - 3" LEVEL 1 F.F.E. = 665' - 0" LEVEL 2 F.F.E. = 674' - 3" LEVEL 1 F.F.E. = 665' - 0" LEVEL 2 F.F.E. = 674' - 3" LEVEL 1 F.F.E. = 665' - 0" LEVEL 2 F.F.E. = 674' - 3" 6' - 0"2' - 0"8' - 0"2' - 0"10' - 0"8"8' - 0"18' - 8"SF-35 SF-36 3' - 4 1/2"1' - 5 1/2"3' - 0"1' - 10" 9' - 8"6' - 0"2' - 0"2' - 0"6' - 0"2' - 0"10' - 0"8"8' - 0"18' - 8"4' - 4"2' - 0"2' - 4" 8' - 8" SF-37 SF-38 6' - 0"2' - 0"2' - 0"6' - 0"2' - 0"10' - 0"8"8' - 0"18' - 8"4' - 0"2' - 8" 6' - 8" SF-39 SF-40 6' - 0"2' - 0"2' - 0"6' - 0"2' - 0"10' - 0"8"8' - 0"18' - 8"4' - 0"2' - 0"4' - 0"3' - 0" 13' - 0" SF-41 SF-428' - 0"8"2' - 0"8' - 0"18' - 8"2' - 8 1/4"6' - 3 3/4" 9' - 0" SF-43 SF-44 5' - 0"2' - 0"2' - 0" 9' - 0"2' - 0"6' - 0"8"2' - 0"8' - 0"18' - 8"SF-46 SF-45 1' - 8"3' - 4" 5' - 0"2' - 0"6' - 0"8"2' - 0"8' - 0"18' - 8"SF-47 SF-48 C dwell design studio - ALL RIGHTS RESERVED JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD, SUITE 200 CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/30/2022 11:56:35 AM C:\Users\lward\Documents\Revit\2247601_MCRT_Foundry_Option 5_laura_ward.rvtA08.21 2247601 STOREFRONT SCHEDULE SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE X MILL CREEK RESIDENTIAL TRUST, LLCTHE FOUNDRY619 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV LEVEL 1 F.F.E. = 665' - 0" LEVEL 2 F.F.E. = 674' - 3" STOREFRONT SCHEDULE Storefront Number Length Height Manufacturer Comments SF-01 9' - 6" 5' - 0" SF-02 9' - 6" 10' - 0" SF-03 11' - 0" 5' - 0" SF-04 11' - 0" 10' - 0" SF-05 9' - 6" 5' - 0" SF-06 9' - 6" 10' - 0" SF-07 12' - 0" 5' - 0" SF-08 12' - 0" 10' - 0" SF-09 10' - 0" 5' - 0" SF-10 10' - 0" 10' - 0" SF-11 6' - 8" 5' - 0" SF-12 6' - 8" 10' - 0" SF-13 10' - 0" 5' - 0" SF-14 10' - 0" 10' - 0" SF-15 11' - 0" 5' - 0" SF-16 11' - 0" 7' - 6" SF-17 11' - 0" 5' - 0" SF-18 10' - 0" 10' - 0" SF-19 20' - 0" 12' - 6" SF-20 9' - 0" 3' - 0" SF-21 9' - 0" 10' - 0" SF-22 10' - 8" 3' - 0" SF-23 10' - 8" 10' - 0" SF-24 10' - 0" 3' - 0" SF-25 10' - 0" 10' - 0" SF-26 14' - 0" 3' - 0" SF-27 14' - 0" 10' - 0" SF-28 9' - 0" 3' - 0" SF-29 9' - 0" 10' - 0" SF-30 18' - 0" 10' - 0" SF-31 10' - 0" 10' - 0" SF-32 17' - 6" 7' - 6" SF-33 17' - 0" 5' - 0" SF-34 17' - 2" 2' - 0" SF-35 9' - 8" 8' - 0" SF-36 9' - 8" 10' - 0" SF-37 8' - 8" 8' - 0" SF-38 8' - 8" 10' - 0" SF-39 6' - 8" 8' - 0" SF-40 6' - 8" 10' - 0" SF-41 13' - 0" 8' - 0" SF-42 13' - 0" 10' - 0" SF-43 9' - 0" 8' - 0" SF-44 9' - 0" 10' - 0" SF-45 9' - 0" 8' - 0" SF-46 9' - 0" 10' - 0" SF-47 5' - 0" 8' - 0" SF-48 5' - 0" 10' - 0" CODES AND STANDARDS ITEM:GOVERNING DOCUMENT: 2018 NORTH CAROLINA STATE BUILDING CODE - (REF: 2015 INTERNATIONAL BUILDING CODE) MECKLENGURG COUNTY REQUIREMENTS ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES" ACI 318-14 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE" TMS 402-13/ACI 530-13/ASCE 5-13 "BUILDING CODE REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES" 1. BUILDING 2. LOADS 3. CONCRETE 4. MASONRY AISC "STEEL CONSTRUCTION MANUAL" 14TH EDITION5. STEEL AWC "NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION" 2015 EDITION AWC "SPECIAL DESIGN PROVISIONS FOR WIND & SEISMIC" 2015 EDITION6. WOOD REFER TO CHAPTER 35 OF THE 2018 NCSBC FOR APPLICABLE VERSIONS OF OTHER STANDARDS REFERENCED THROUGHOUT THE DRAWINGS. 7. OTHER REFERENCED STANDARDS CITY OF CHARLOTTE REQUIREMENTS BUILDING STRUCTURAL LOADING ITEM:DESIGN INFORMATION/LOADING:GOVERNING DOCUMENT: ALLOWABLE BEARING PRESSURE = 5000 PSF SUB-GRADE REACTION MODULUS = 120 PCI UNIT WEIGHT OF SOIL = 120 PCF ACTIVE EARTH PRESSURE = 45 PCF AT-REST EARTH PRESSURE = 66 PCF PASSIVE EARTH PRESSURE = 336 PCF COEFFICIENT OF FRICTION = 0.35 1. SOIL LOADS GEOTECHNICAL REPORT: GEO-HYDRO ENGINEERS DATED JULY 13, 2022 AND SUPPLEMENTAL REPORTS DATES OCTOBER 24, 2022 AND XXX ULTIMATE DESIGN WIND SPEED = 115 MPH NOMINAL DESIGN WIND SPEED = 89 MPH RISK CATEGORY = II EXPOSURE CATEGORY = B INTERNAL PRESSURE COEFFICIENT = +/- 0.18 COMPONENTS AND CLADDING WIND PRESSURES = SEE SCHEDULE ON S001 2. WIND DESIGN ASCE 7 EXPOSURE FACTOR = 0.9 THERMAL FACTOR = 1.0 IMPORTANCE FACTOR = 1.0 ROOF SLOPE FACTOR = 1.0 FLAT ROOF SNOW LOAD = 10 PSF GROUND SNOW LOAD = 10 PSF 4. SNOW LOADS ASCE 7 IMPORTANCE FACTOR = 1.0 OCCUPANCY CATEGORY = II SS = 0.239g S1= 0.103g SITE CLASS = D SDS = 0.255g SD1 = 0.164g DESIGN CATEGORY = C R (WOOD) = 6.5 Cs (WOOD) = X.XXX ASD DESIGN BASE SHEAR (WOOD) = XXX KIPS ANALYSIS PROCEDURE UTILIZED (WOOD) = EQUIVALENT LATERAL FORCE PROCEDURE 3. SEISMIC DESIGN ASCE 7 SEISMIC RESISTING SYSTEM (WOOD) = LIGHT-FRAME BEARING WALLS SHEATHED WITH WOOD STRUCTURAL PANELS R (CONCRETE) = 5.0 Cs (CONCRETE) = X.XXX ASD DESIGN BASE SHEAR (CONCRETE) = XXX KIPS ANALYSIS PROCEDURE UTILIZED (CONCRETE) = EQUIVALENT LATERAL FORCE PROCEDURE SEISMIC RESISTING SYSTEM (CONCRETE) = ORDINARY REINFORCED CONCRETE SHEAR WALLS ASD DESIGN BASE SHEAR (TOTAL BUILDING) = XXX KIPS ANALYSIS PROCEDURE UTILIZED (TOTAL BUILDING) = TWO- STAGE GRAVITY DEAD AND LIVE LOADS UNIFORMLY DISTRIBUTED LOADS SUPERIMPOSED DEAD LOAD LIVE LOAD CONCENTRATED LIVE LOADMATERIAL ELEMENT/AREA TOP BOTTOM 15 PSFSLAB ON GRADE - RESIDENTIAL SLAB ON GRADE - ASSEMBLY AND CORRIDOR CONCRETE DESIGN LOADS 5 PSF N/A N/A 40 PSF 100 PSF SLAB ON GRADE - LIGHT STORAGE 5 PSF N/A 125 PSF (1) 25 PSFUNITS 5 PSF 40 PSF 25 PSFASSEMBLY AND CORRIDOR 5 PSF 100 PSF (4) 10 PSFBALCONIES N/A 60 PSF WOOD FLOOR DESIGN LOADS 15 PSFROOF TRUSSES 15 PSFROOF RAFTERS/JOISTS WOOD ROOF DESIGN LOADS STAIRS N/A STEEL DESIGN LOADS N/A UTILITY/LIGHT STORAGE 25 PSF 5 PSF 125 PSF (1) 5 PSF 5 PSF 20 PSF (5)(6) 20 PSF (5) 300 LBS 100 PSF 300 LBS (3) 1. LIVE LOAD REDUCTION IS NOT PERMITTED. 2. LOAD APPLIED TO AN AREA OF 4½"x4½". 3. LOAD APPLIED TO AN AREA OF 2"x2" ON STAIR TREADS NON-CONCURRENT WITH UNIFORM LIVE LOAD. 4. LOAD REPRESENTS ROOF LIVE LOAD. SEE SNOW LOAD SECTION FOR ADDITIONAL LOADING CONDITIONS TO BE CONSIDERED. TRUSS MANUFACTURER TO CONSIDER UNBALANCED SNOW LOADS. 5. TRUSS MANUFACTURER TO APPLY ADDITIONAL BOTTOM CHORD LIVE LOAD FOR ATTIC SPACES BASED ON TRUSS CONFIGURATIONS PER ASCE 7 REQUIREMENTS. 6. CONTRACTOR TO PROVIDE TRUSS MANUFACTURER WITH SPRINKLER SYSTEM DESIGN AND LAYOUT AND COORDINATE ROOF AND FLOOR TRUSS DESIGN WITH SPRINKLER SYSTEM LOADING REQUIREMENTS. 7. HANDRAILS, GUARDRAILS, VEHICLE BARRIERS AND IMPACT LOADS SHALL BE APPLIED PER ASCE 7 REQUIREMENTS. 40 PSFROOF TRUSSES AT MECHANICAL 5 PSF 20 PSF (5)(6)300 LBS 5 PSFSLAB ON GRADE - PARKING N/A 40 PSF (1)3000 LBS (2) 20 PSFELEVATED SLAB - RESIDENTIAL 10 PSF 40 PSF N/AELEVATED SLAB - PARKING 5 PSF 40 PSF (1)3000 LBS (2) ELEVATED SLAB - ASSEMBLY AND CORRIDOR 20 PSF 10 PSF 100 PSF ELEVATED SLAB - LIGHT STORAGE 5 PSF 10 PSF 125 PSF (1) 5 PSFSTAIRS 10 PSF 100 PSF 300 LBS (3) COMPONENTS AND CLADDING WIND PRESSURES 1 10 SQ. FT. 20 SQ. FT. 50 SQ. FT. 100 SQ. FT. EFFECTIVE AREA ROOF ZONES WALL ZONES 1. WIND PRESSURES SHOWN ARE NOMINAL (0.6W). 2. COMPONENTS AND CLADDING SHALL BE DESIGNED TO RESIST BOTH NEGATIVE AND POSITIVE PRESSURES HAVING MAGNITUDES SHOWN ABOVE. 3. SEE ASCE 7 FOR ZONE LOCATIONS. 4. EDGE DISTANCE DIMENSION "a" = 34'. 19.2 PSF 18.7 PSF 18.1 PSF 17.6 PSF 2 32.3 PSF 28.8 PSF 24.3 PSF 20.9 PSF 3 48.5 PSF 40.4 PSF 29.2 PSF 20.9 PSF 4 19.1 PSF 18.3 PSF 17.3 PSF 16.4 PSF 5 23.5 PSF 22.0 PSF 19.8 PSF 18.3 PSF GENERAL PROVISIONS ITEM: DESCRIPTION: STRUCTURAL DRAWINGS ARE NOT STAND-ALONE CONSTRUCTION DOCUMENTS. THEY REQUIRE THE USE OF TECHNICAL SPECIFICATIONS AND DESIGN DRAWINGS FROM ALL NECESSARY DISCIPLINES TO EFFECTIVELY COMMUNICATE THE INTENDED DESIGN. THE STRUCTURAL DESIGN INDICATED IS BASED ON THE COMPLETED WORK. NOTES AND TYPICAL DETAILS APPLY GENERALLY THROUGHOUT THE PROJECT WHEREVER CONDITIONS SIMILAR TO THOSE DEPICTED EXIST AND ARE NOT REFERENCED SPECIFICALLY IN THE DOCUMENTS. 1. STRUCTURAL DRAWINGS SHOULD CONFLICTS ARISE BETWEEN THE QUANTITIES, SIZES, OR STRENGTHS INDICATED WITHIN THE PLANS, SPECIFICATIONS, NOTES, OR DETAILS - THE MORE STRINGENT, LARGER, OR HIGHER STRENGTH ELEMENT SHOULD BE CONSIDERED UNTIL DISCREPANCY IS PROPERLY ADDRESSED. 2. STRUCTURAL CONFLICTS GENERAL CONTRACTOR SHALL REVIEW THE DESIGN DRAWINGS FOR ALL DISCIPLINES AND NOTIFY THE ARCHITECT AND ENGINEERS OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 3. DISCREPANCIES GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT AND ENGINEER SHOULD FIELD CONDITIONS EXIST THAT DO NOT PERMIT THE CONSTRUCTION TO PROCEED IN ACCORDANCE WITH THE CONSTRUCTION DOCUMENTS. 4. UNFORESEEN FIELD CONDITIONS MEANS AND METHODS OF CONSTRUCTION ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. GENERAL CONTRACTOR SHALL INSURE THAT ITS OPERATIONS AND PROCEDURES DO NOT RESULT IN THE APPLICATION OF LOADS TO ANY MEMBER GREATER THAN THE DESIGN LOADS LISTED. TEMPORARY BRACING OF THE STRUCTURE DURING CONSTRUCTION IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. DESIGNS FOR SECONDARY ELEMENTS ASSOCIATED WITH SAFETY MEASURES ARE BEYOND THE SCOPE OF THE STRUCTURAL DRAWINGS AND APPLICABLE DESIGNS SHOULD BE SUBMITTED TO THE GENERAL CONTRACTOR. 5. MEANS AND METHODS RFI'S AND REQUESTS FOR SUBSTITUTIONS SHALL BE SUBMITTED TO THE ARCHITECT WITH PROPOSED SOLUTIONS OR MODIFICATIONS. WORK RELATED TO RFI'S AND SUBSTITUTION REQUESTS SHALL NOT COMMENCE UNTIL APPROPRIATE APPROVAL IS PROVIDED. 6. RFI'S AND SUBSTITUTIONS SHOP DRAWINGS SHALL BE PREPARED BASED ON THE CONSTRUCTION DRAWINGS AND ANY ADDENDUMS PRODUCED. FABRICATION PRIOR TO SHOP DRAWING APPROVAL IS AT THE SOLE RISK OF THE GENERAL CONTRACTOR. SER IS NOT RESPONSIBLE FOR SHOP DRAWINGS NOT REVIEWED. 7. SHOP DRAWINGS DIVISION 03 - CONCRETE ITEM: DESCRIPTION: FOOTINGS - 4500 PSI NW CONCRETE FOUNDATION AND BASEMENT WALLS - 5000 PSI NW CONCRETE, AIR ENTRAINED EXTERIOR AND/OR PARKING SLABS ON GRADE - 5000 PSI NW CONCRETE, AIR ENTRAINED 2. CONCRETE 28-DAY DESIGN STRENGTH 4. MAXIMUM WATER/CEMENT RATIO 6. AIR ENTRAINMENT BILLET STEEL, GRADE 60, IN ACCORDANCE WITH ASTM A615 WELDED WIRE FABRIC IN ACCORDANCE WITH ASTM A185 LAP WELDED WIRE FABRIC 2 SQUARES OR 8" IN EACH DIRECTION MINIMUM 8. REINFORCEMENT MAXIMUM 4" ± 1" CAST AGAINST AND EXPOSED TO EARTH = 3" EXPOSED TO EARTH OR WEATHER (#6 OR LARGER) = 2" EXPOSED TO EARTH OR WEATHER (#5 OR SMALLER) = 1½" 9. CONCRETE COVER 10. TIES AND CHAIRS 11. FORMWORK AND RESHORING FORMWORK AND/OR RESHORING DESIGN SHALL BE PROVIDED BY OTHERS RESHORING IS REQUIRED TO REMAIN IN PLACE AT ELEVATED SLABS FOR A MINIMUM OF 21 DAYS TO MINIMIZE EFFECTS OF LONG TERM DEFLECTION 12. SUBMITTALS REQUIRED SLEEVING PLAN FOR ELEVATED CONCRETE WORK CONCRETE MIX DESIGN (INCLUDING ADMIXTURES) REINFORCEMENT PLACEMENT DRAWINGS FORMWORK AND SHORING DESIGNS INTERIOR SLABS ON GRADE - 3500 PSI NW CONCRETE ELEVATED SLABS - 6000 PSI NW CONCRETE COLUMNS AND SHEAR WALLS - 5000 PSI NW CONCRETE 5. SLUMP MAY BE INCREASED WITH APPROVED ADMIXTURE CONCRETE EXPOSED TO FREEZE AND THAW CYCLES AT FINAL USAGE SHALL BE IN ACCORDANCE WITH ACI 318 TABLE 19.3.3.1 BILLET STEEL, GRADE 60, IN ACCORDANCE WITH ASTM A775/A775M BEAMS AND COLUMNS = 1½" INTERIOR WALLS AND SHEAR WALLS = 1½" ELEVATED SLAB BOTTOM BARS = 1" ELEVATED SLAB TOP BARS (EXTERIOR AND/OR PARKING SLABS) = 2" ELEVATED SLAB TOP BARS (INTERIOR SLABS) = 1" PROVIDE ADEQUATE TIES AND CHAIRS FOR REINFORCEMENT WITHIN SLABS, BEAMS, COLUMNS AND WALLS TO MAINTAIN CORRECT SPACING AND COVER FROM FORMWORK STRIPPING OF FORMWORK FOR ELEVATED SLABS MAY BE COMPLETED IN A MINIMUM OF 3 DAYS AND WHEN CONCRETE HAS REACHED A MINIMUM OF 75% OF THE DESIGN STRENGTH TOWER CRANE LAYOUT AND FOUNDATION DESIGN ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE"1. ADDITIONAL STANDARDS ACI 315 "DETAILS AND DETAILING OF CONCRETE REINFORCEMENT" 3500 PSI NW CONCRETE - 0.55 4500 PSI NW CONCRETE - 0.45 5000-6000 PSI NW CONCRETE - 0.40 CONCRETE EXPOSED TO DEICING CHEMICALS SHALL BE IN ACCORDANCE WITH ACI 318 TABLE 26.4.2.2(B) 3. CEMENTIOUS MATERIAL ALL NON-SHRINK GROUT SHALL CONFORM TO ASTM C1107 MINIMUM COMPRESSIVE STRENGTH OF 5000 PSI 7. NON-SHRINK GROUT DIVISION 04 - MASONRY ITEM: DESCRIPTION: FOUNDATION WALLS - f'm = 2000 PSI, CONCRETE MASONRY UNIT WITH TYPE S MORTAR EXTERIOR/BEARING WALLS - f'm = 2000 PSI, CONCRETE MASONRY UNIT WITH TYPE S MORTAR INTERIOR NON-BEARING WALLS - f'm = 1740 PSI, CONCRETE MASONRY UNIT WITH TYPE N MORTAR VENEER - f'm = 1098 PSI, CLAY MASONRY UNIT WITH TYPE N MORTAR 2. NET AREA COMPRESSIVE STRENGTH CONCRETE - NORMAL WEIGHT ASTM C90 WITH COMPRESSIVE STRENGTH OF 2000 PSI VENEER - MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI 3. MASONRY UNIT 4. MORTAR ALL MASONRY GROUT SHALL CONFORM TO ASTM C476 MINIMUM COMPRESSIVE STRENGTH OF 2000 PSI MASONRY UNITS BELOW GRADE SHALL BE FULLY GROUTED 5. MASONRY GROUT ALL MORTAR SHALL BE CEMENT-LIME OR MORTAR CEMENT CONFORMING TO ASTM C270 TYPE S - AVERAGE COMPRESSIVE STRENGTH OF 1800 PSI TYPE N - AVERAGE COMPRESSIVE STRENGTH OF 750 PSI 9 GA. MINIMUM LADDER OR TRUSS TYPE MAXIMUM 16" O.C. VERTICAL SPACING ABOVE GRADE UNLESS NOTED OTHERWISE LAP 8" MINIMUM HORIZONTALLY 7. JOINT REINFORCING BILLET STEEL, GRADE 60, IN ACCORDANCE WITH ASTM A615 PLACE BARS IN CENTER OF FULLY GROUTED MASONRY CELLS LAP 2'-0" MINIMUM VERTICALLY 8. VERTICAL REINFORCEMENT HOHMANN AND BARNARD DW-10, HOHMANN AND BARNARD X-SEAL OR HECKMANN 315-D ANCHORS SPACED EVERY 2.67 SQUARE FEET AND MAXIMUM 32" O.C. HORIZONTALLY AND 25" O.C. VERTICALLY 9. VENEER ANCHORS PROVIDE ADDITIONAL ANCHORS AROUND OPENINGS LARGER THAN 16" IN EITHER DIMENSION SPACE ANCHORS AROUND PERIMETER OF OPENING AT A MAXIMUM OF 3'-0" O.C. AND WITHIN 12" OF OPENING 11. SUBMITTALS REQUIRED ACCESSORIES MASONRY UNITS MORTAR AND GROUT MIX DESIGNS (INCLUDING ADMIXTURES) REINFORCEMENT PLACEMENT DRAWINGS ALL MASONRY SHALL BE LAID WITH A RUNNING BOND PATTERN6. BOND PATTERN PROVIDE CONTROL AND EXPANSION JOINTS PER "BRICK INDUSTRY OF AMERICA TECHNICAL NOTE 18A" AND PER THE ARCHITECTURAL DRAWINGS. 10. VENEER CONTROL AND EXPANSION JOINTS NATIONAL CONCRETE MASONRY ASSOCIATION (NCMA) TEK MANUAL BRICK INDUSTRY OF AMERICA (BIA) TECHNICAL NOTES 1. ADDITIONAL STANDARDS MAXIMUM 8" O.C. VERTICAL SPACING BELOW GRADE UNLESS NOTED OTHERWISE DIVISION 05 - METALS ITEM: DESCRIPTION: ASTM A992 FOR W-SHAPES (50 KSI) ASTM A500 GR. B FOR HSS-SHAPES (42 KSI ROUND, 46 KSI RECTANGULAR) ASTM A53 GR. B FOR PIPES (35 KSI) ASTM A36 FOR PLATES, L-SHAPES, C-SHAPES, AND MC-SHAPES (36 KSI) 1. STRUCTURAL STEEL PER AWS D1.1 USE E70XX ELECTRODE2. WELDS U.N.O. ON DRAWINGS, CONNECTIONS ARE TO BE AISC STANDARD DESIGNED FOR THE ASD REACTIONS INDICATED. WHERE REACTIONS ARE NOT PROVIDED, DESIGN FOR 50% OF MAXIMUM ALLOWABLE STRESS. 3. CONNECTIONS ALL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED OR UTILIZE AN APPROVED PROTECTIVE COATING 4. CORROSION RESISTANCE PROVIDE PLANS, ELEVATIONS, SECTIONS, LOCATIONS, CONNECTIONS, AND CALCULATIONS (SIGNED AND SEALED) FOR EACH OF THE FOLLOWING: STRUCTURAL STEEL PREFABRICATED STAIRS GUARDRAILS 5. SUBMITTALS REQUIRED U.N.O. ON DRAWINGS, ALL ANCHORS BOLTS SHALL BE HILTI HEX HEAD ASTM F1554 GR. 36 DIVISION 06 - WOOD FRAMING ITEM: DESCRIPTION: SPF #2 FOR BEARING WALL STUDS, RAFTERS, JOISTS, HEADERS AND BEAMS UNLESS NOTED OTHERWISE 1. DIMENSIONAL LUMBER SP #2 FOR BEARING WALL TOP AND BOTTOM PLATES AND FRAMING EXPOSED TO EXTERIOR STUD GRADE LUMBER MAY BE USED AT NON-BEARING WALLS LUMBER SHALL BE DELIVERED TO THE SITE WITH A MOISTURE CONTENT LESS THAN OR EQUAL TO 19% LVL BEAM - Fb (2600), FC PERP. (750), FV (285), E (2E6) PSL BEAM - Fb (2900), FC PERP (750), FV (290), E (2E6) PSL COLUMN - Fb (2400), FC (2500), FV (190), E (1.8E6) WOLMANIZED PSL BEAM SERVICE LEVEL 2 - Fb (1827), FC PERP (338), FV (197), E (1.4E6) WOLMANIZED PSL COLUMN SERVICE LEVEL 2 - Fb (1440), FC (1300), FV (120), E (1.2E6) 2. ENGINEERED LUMBER STRUCUTRAL SHEATHING PANELS SHALL BE APA RATED EXPOSURE I EXTERIOR - 7/16" FIRE RATED OSB WITH CEMENTITIOUS COATING ON 2-SIDES (24/16 SPAN RATING) OR 19/32" FIRE RETARDANT TREATED PLYWOOD (40/20 SPAN RATING) FLOOR - 23/32" OSB (48/24 SPAN RATING) FLAT ROOF - 23/32" OSB (48/24 SPAN RATING) PITCHED ROOF - 19/32" OSB (40/20 SPAN RATING) 3. SHEATHING TRUSS DESIGN AND INSTALLATION SHALL BE IN ACCORDANCE WITH "TRUSS PLATE INSTITUTE" (TPI) AND "BUILDING COMPONENT SAFETY INFORMATION" (BCSI) TRUSSES SHALL BE DESIGNED FOR LOADS INDICATED ON COVER SHEET IN ADDITION TO ANY SPECIFIC LOADING SHOWN ON PLAN ROOF TRUSS LOADING SHALL CONSIDER SNOW, SNOW DRIFTS, PONDING, AND LOADS RESULTING FROM MECHANICAL EQUIPMENT INDIVIDUAL ROOF TRUSS MEMBERS SHALL BE DESIGNED FOR COMPONENTS AND CLADDING LOADS INDICATED ROOF TRUSS UPLIFT REACTIONS SHALL BE BASED ON MAIN WIND FORCE PARAMETERS INDICATED LIVE LOAD DEFLECTION SHALL NOT EXCEED L/480 FOR FLOOR TRUSSES AND L/360 FOR ROOF TRUSSES TOTAL LOAD DEFLECTION SHALL NOT EXCEED L/240 UP TO 1/2" FOR FLOOR TRUSSES AND 1" FOR ROOF TRUSSES DIFFERENTIAL TOTAL LOAD DEFLECTION OF ADJACENT TRUSSES SHALL NOT EXCEED 1/4" FOR FLOOR TRUSSES AND 3/8" FOR ROOF TRUSSES TRUSS DESIGNER IS RESPONSIBLE FOR ALL TRUSS-TO-TRUSS CONNECTIONS INCLUDING CONNECTIONS FOR MULTI-PLY TRUSSES TRUSSES SHALL NOT BE CUT, NOTCHED, OR MODIFIED IN ANY WAY WITHOUT PRIOR APPROVAL FROM TRUSS DESIGNER 4. PRE-FABRICATED TRUSSES ALL LUMBER USED IN EXTERIOR APPLICATIONS OR IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESERVATIVE-TREATED IN ACCORDANCE WITH AWPA STANDARD U1 CONNECTORS AND FASTENERS IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL HAVE COATING TYPES AND WEIGHTS IN ACCORDANCE WITH THE TREATED WOOD OR CONNECTOR MANUFACTURER'S SPECIFICATIONS 5. PRESERVATIVE- TREATED 7. CONNECTIONS WOOD BLOCKING FOR SECONDARY, NON-STRUCTURAL ELEMENTS IS NOT INDICATED WITHIN THE STRUCTURAL DRAWINGS, BUT SHOULD BE COORDINATED WITH OTHER TRADES 8. MISCELLANEOUS FRAMING LUMBER SPECIFICATIONS SHEATHING FLOOR TRUSSES CALCULATIONS (SIGNED AND SEALED) WITH LAYOUT SHEETS ROOF TRUSSES CALCULATIONS (SIGNED AND SEALED) WITH LAYOUT SHEETS CONNECTORS, FASTENERS, AND ADHESIVES SPRINKLER SYSTEM DESIGN 9. SUBMITTALS REQUIRED ANCHOR ROD CALCULATIONS (SIGNED AND SEALED) WITH LAYOUT SHEETS (IF REQUIRED) INTERIOR SHEAR WALLS - 7/16" OSB (24/16 SPAN RATING) FLOOR AT EXTERIOR WALL - 23/32" FIRE RETARDANT TREATED PLYWOOD (48/24 SPAN RATING) FLAT ROOF AT FIREWALL - 23/32" FIRE RETARDANT TREATED PLYWOOD (48/24 SPAN RATING) PITCHED ROOF AT FIREWALL - 19/32" FIRE RETARDANT TREATED PLYWOOD (40/20 SPAN RATING) ALL LUMBER USED FOR EXTERIOR WALL FRAMING SHALL BE FIRE RETARDANT TREATED ALL FLOOR SHEATHING PENETRATING EXTERIOR WALLS SHALL BE FIRE RETARDANT TREATED PROVIDE FIRE RETARDANT TREATED ROOF SHEATHING FOR A DISTANCE OF 4' ON BOTH SIDES OF FIREWALLS6. FIRE RETARDANT TREATED PANELS AT ROOFS AND FLOORS SHALL HAVE TONGUE AND GROOVE EDGES OR CLIPS SHALL BE PROVIDED AT UNSUPPORTED PANEL EDGES ALL PANELS SHALL BE INSTALLED PER APA RECOMMENDATIONS PROVIDE ⅛" GAP BETWEEN ALL PANEL EDGE AND END JOINTS UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER CONNECTORS AND FASTENERS SHALL BE INSTALLED AS SPECIFIED ON THE STRUCTURAL PLANS AND IN ACCORDANCE WITH THE MANUFACTURER'S REQUIREMENTS FOR MAXIMUM CAPACITY UNLESS NOTED OTHERWISE THRU BOLTED CONNECTIONS SHALL UTILIZE ASTM A307 GRADE A BOLTS UNLESS NOTED OTHERWISE DESIGN VALUE ADJUSTMENT FACTORS: Fb CONNECTIONS 0.88 Ft 0.83 Fv 0.93 Fc 0.94 Fc 0.95 E 0.94 EMIN 0.94 0.90 LIST OF ABBREVIATIONS A.B.ANCHOR BOLT LSL LAMINATED STRAND LUMBER A.F.F. ABOVE FINISHED FLOOR LVL LAMINATED VENEER LUMBER BM BEAM N.T.S. NOT TO SCALE B.O.F. BOTTOM OF FOOTING O.C. ON CENTER CANT. CANTILEVER O.F. OUTSIDE FACE C.I.P. CAST IN PLACE OSB ORIENTED STRAND BOARD C.J. CONTROL JOINT PL PLATE CLR CLEAR PLF POUNDS PER LINEAR FOOT COL. COLUMN PSF POUNDS PER SQUARE FOOT CONT. CONTINUOUS PSI POUNDS PER SQUARE INCH DBL DOUBLE PSL PARALLEL STRAND LUMBER EA. EACH P.T. PRESERVATIVE TREATED E.E. EACH END REQ REQUIRED E.F. EACH FACE SER STRUCTURAL ENGINEER OF RECORD E.J. EXPANSION JOINT S.O.G. SLAB ON GRADE EL. ELEVATION SQ SQUARE E.O.R. ENGINEER OF RECORD STL STEEL E.O.S. EDGE OF SLAB S.W. SHEAR WALL E.W. EACH WAY T & B TOP AND BOTTOM (REINFORCEMENT) F.F.E. FINISHED FLOOR ELEVATION T & G TONGUE AND GROOVE FRT FIRE RETARDANT TREATED T.O.B. TOP OF BEAM FTAO FORCE TRANSFER AROUND OPENING T.O.C. TOP OF CONCRETE FTG FOOTING T.O.F. TOP OF FOOTING F.S. FOOTING STEP T.O.S. TOP OF STEEL G.B. GRADE BEAM T.O.W. TOP OF WALL G.T. GIRDER TRUSS TYP. TYPICAL HDR HEADER U.N.O. UNLESS NOTED OTHERWISE I.F. INSIDE FACE VEF VERTICAL EACH FACE LLH LONG LEG HORIZONTAL WF WIDE FLANGE SECTION LLV LONG LEG VERTICAL W.W.M. WELDED WIRE MESH LONG LONGITUDINAL W/ WITH DIVISION 31 - EARTHWORK ITEM: DESCRIPTION: EARTHWORK SHALL BE PERFORMED IN ACCORDANCE WITH THE GEOTECHNICAL REPORT FROM GEO-HYDRO ENGINEERS DATED JULY 13, 2022 AND SUPPLEMENTAL REPORTS. 1. GEOTECHNICAL REPORT SEE BUILDING STRUCTURAL LOADING NOTES FOR SOIL DESIGN INFORMATION. SOIL BEARING CAPACITY SHALL BE VERIFIED BY A GEOTECHNICAL ENGINEER JUST PRIOR TO PLACEMENT OF FOUNDATION. 2. SOIL DESIGN VALUES BOTTOM OF FOOTINGS SHALL BE PLACED AT THE LOWEST OF: A) ELEVATIONS INDICATED ON THE FOUNDATION PLANS B) ELEVATIONS REQUIRED TO MAINTAIN A FROST DEPTH OF 18" BELOW FINISH GRADE C) ELEVATIONS REQUIRED TO MAINTAIN A MAXIMUM SLOPE OF 2H:1V FROM BOTTOM OF ADJACENT UTILITIES AND FOUNDATIONS 3. FOOTING ELEVATIONS UTILIZE GRANULAR MATERIAL WITH THE PARAMETERS AS SPECIFIED WITHIN THE GEOTECHNICAL REPORT. 6. BACKFILL MATERIAL AND OPERATIONS THE BOTTOM OF ALL EXCAVATION SHALL BE DRY AND LEVEL PRIOR TO PLACEMENT OF SUBBASE AND CONCRETE.7. DEWATERING PROTECT EXISTING UNDERGROUND UTILITIES FROM DAMAGE DURING EARTHWORK PROCEDURES.8. EXISTING UTILITIES SITE WORK SHALL BE COMPLETED IN ACCORDANCE WITH LOCAL REGULATIONS AND OSHA REQUIREMENTS.9. SAFETY PROVISIONS MIN. 10 MIL VAPOR BARRIER BELOW ALL SLABS ON GRADE AS SPECIFIED IN THE GEOTECHNICAL REPORT. MIN. 4" LAYER OF OPEN-GRADED STONE AS SPECIFIED IN THE GEOTECHNICAL REPORT. COORDINATE ADDITIONAL REQUIREMENTS WITH ARCHITECTURAL DRAWINGS AND GEOTECHNICAL REPORT. 5. VAPOR BARRIER AND SUB-BASE MATERIAL NO HEAVY COMPACTION EQUIPMENT IS PERMITTED WITHIN 5 FEET OF BASEMENT WALLS. PROTECT SUBGRADE FROM FREEZING PRIOR TO PLACEMENT OF FOUNDATIONS AND SLABS ON GRADE.4. SUBGRADE FOUNDATION WALLS BELOW GRADE AND LOWEST LEVEL SLAB SHALL BE BACKFILLED ON BOTH SIDES SIMULTANEOUSLY BASEMENT/FOUNDATION WALLS ABOVE THE LOWEST LEVEL SLAB SHALL NOT BE BACKFILLED UNTIL UPPER FLOOR OR ROOF IS IN PLACE DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:17 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS00.01 Author Checker DDS-025-22 DESIGN CRITERIA AND STRUCTURAL SPECIFICATIONS SCHEMATIC DESIGN PACKAGE FOUNDRY 601-622 SOUTH CEDAR ST. CHARLOTTE, NC 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCSHEET INDEX SHEET # SHEET NAME SD SUBMISSIONS00.01 DESIGN CRITERIA AND STRUCTURAL SPECIFICATIONS X S00.02 GENERAL SCHEDULES AND SPECIAL INSPECTIONS X S00.03 COUNTY SPECIAL INSPECTIONS FORMS X S01.11 TYPICAL FOUNDATION DETAILS X S01.12 FOUNDATION DETAILS X S01.21 CONCRETE COLUMN DETAILS X S01.41 TYPICAL ELEVATED SLAB DETAILS X S01.42 ELEVATED SLAB DETAILS X S01.61 MASONRY DETAILS X S02.01A FOUNDATION PLAN - PART A X S02.01B FOUNDATION PLAN - PART B X S02.01C FOUNDATION PLAN - PART C X S02.02A LEVEL 2 ELEVATED SLAB PLAN - PART A X S02.02B LEVEL 2 SLAB/FOUNDATION PLAN - PART B X S02.02C LEVEL 2 ELEVATED SLAB PLAN - PART C X S02.03A LEVEL 3 ELEVATED SLAB PLAN - PART A X S02.03AR LEVEL 3 ELEVATED SLAB REINF. PLAN - PART A X S02.03B LEVEL 3 ELEVATED SLAB PLAN - PART B X S02.03BR LEVEL 3 ELEVATED SLAB REINF. PLAN - PART B X S02.03C LEVEL 3 ELEVATED SLAB PLAN - PART C X S02.03CR LEVEL 3 ELEVATED SLAB REINF. PLAN - PART C X S02.04A LEVEL 4 ELEVATED SLAB PLAN - PART A X S02.04AR LEVEL 4 ELEVATED SLAB REINF. PLAN - PART A X S02.04B LEVEL 4 ELEVATED SLAB PLAN - PART B X S02.04BR LEVEL 4 ELEVATED SLAB REINF. PLAN - PART B X S02.04C LEVEL 4 ELEVATED SLAB PLAN - PART C X S02.04CR LEVEL 4 ELEVATED SLAB REINF. PLAN - PART C X S02.05A LEVEL 5 ELEVATED SLAB PLAN - PART A X S02.05AR LEVEL 5 ELEVATED SLAB REINF. PLAN - PART A X S02.05B LEVEL 5 ELEVATED SLAB PLAN - PART B X S02.05BR LEVEL 5 ELEVATED SLAB REINF. PLAN - PART B X S02.06A LEVEL 6 ELEVATED SLAB PLAN - PART A X S02.06AR LEVEL 6 ELEVATED SLAB REINF. PLAN - PART A X S02.06B LEVEL 6 ELEVATED SLAB PLAN - PART B X S02.06BR LEVEL 6 ELEVATED SLAB REINF. PLAN - PART B X S03.05C LEVEL 5 FLOOR FRAMING PLAN - PART C X S03.06C LEVEL 6 FLOOR FRAMING PLAN - PART C X S03.07A LEVEL 7 FLOOR FRAMING PLAN - PART A X S03.07B LEVEL 7 FLOOR FRAMING PLAN - PART B X S03.07C LEVEL 7 FLOOR FRAMING PLAN - PART C X S03.08A LEVEL 8 FLOOR FRAMING PLAN - PART A X S03.08B LEVEL 8 FLOOR FRAMING PLAN - PART B X S03.08C LEVEL 8 FLOOR FRAMING PLAN - PART C X S03.09A LEVEL 9 FLOOR FRAMING PLAN - PART A X S03.09B LEVEL 9 FLOOR FRAMING PLAN - PART B X S03.09C LEVEL 9 LOW ROOF FRAMING PLAN - PART C X S03.10A LEVEL 10 FLOOR FRAMING PLAN - PART A X S03.10B LEVEL 10 FLOOR FRAMING PLAN - PART B X S03.11A LEVEL 11 ROOF FRAMING PLAN - PART A X S03.11B LEVEL 11 ROOF FRAMING PLAN - PART B X S04.01A SHEAR WALL LAYOUT PLAN - PART A X S04.01B SHEAR WALL LAYOUT PLAN - PART B X S04.01C SHEAR WALL LAYOUT PLAN - PART C X S04.11 SHEAR WALL DETAILS X S05.11 TYPICAL WOOD FRAMING DETAILS X S05.12 WOOD FRAMING DETAILS X S05.13 WOOD FRAMING AT BALCONIES X S05.21 ROOF FRAMING DETAILS X TOTAL SHEETS: 58 DATE DESCRIPTION REV SPECIAL INSPECTIONS 1. THE OWNER OR THE OWNER'S AUTHORIZED AGENT SHALL EMPLOY ONE OR MORE APPROVED AGENCIES TO PROVIDE SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION FOR ALL STRUCTURAL SYSTEMS AND ELEMENTS LISTED HEREIN. 4. APPROVED AGENCIES SHALL KEEP DETAILED RECORDS OF ALL SPECIAL INSPECTIONS AND TESTS AND SHALL SUBMIT REPORTS IN A TIMELY FASHION TO THE BUILDING OFFICIAL AND SER WHICH INDICATE THAT WORK INSPECTED OR TESTED WAS OR WAS NOT COMPLETED IN CONFORMANCE TO THE APPROVED CONSTRUCTION DOCUMENTS. 2. IN ADDITION TO THE SPECIAL INSPECTIONS PROGRAM, QUALITY CONTROL PROGRAMS AND PROCEDURES SHALL BE IMPLEMENTED BY ALL CONTRACTORS, SUBCONTRACTORS, SUPPLIERS, AND OTHER ENTITIES FURNISHING MATERIALS OR PERFORMING ANY WORK ON THE PROJECT. 3. CREDENTIALS OF ALL APPROVED AGENCIES AND SPECIAL INSPECTORS SHALL BE PROVIDED TO THE BUILDING OFFICIAL AND SER PRIOR TO THE START OF CONSTRUCTION. 5. DISCREPANCIES BETWEEN THE INSPECTED WORK AND THE APPROVED CONSTRUCTION DOCUMENTS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE GENERAL CONTRACTOR FOR CORRECTION. IF THEY ARE NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL AND SER PRIOR TO THE COMPLETION OF THAT PHASE OF WORK. 6. APPROVED AGENCIES SHALL SUBMIT A FINAL REPORT TO THE BUILDING OFFICIAL AND SER DOCUMENTING THE REQUIRED SPECIAL INSPECTIONS AND TESTS, THE CORRECTION OF ANY DISCREPANCIES, AND INDICATING THAT THE FINAL INSPECTED CONSTRUCTION IS IN CONFORMANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. 7. SPECIAL INSPECTIONS SHALL BE PERFORMED ON A CONTINUOUS OR PERIODIC BASIS AS INDICATED. CONTINUOUS AND PERIODIC SPECIAL INSPECTIONS ARE DEFINED AS: A. CONTINUOUS - SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS PRESENT CONTINUOUSLY WHEN AND WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED. B. PERIODIC - SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEGIN PERFORMED. 8. SPECIAL INSPECTIONS OF SHOP FABRICATED STRUCTURAL, LOAD-BEARING OR LATERAL LOAD-RESISTING MEMBERS OR ASSEMBLIES SHALL BE CONDUCTED ON THE PREMISES OF THE FABRICATOR'S SHOP DURING FABRICATION. 9. SPECIAL INSPECTIONS ARE NOT REQUIRED FOR FABRICATORS REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTIONS BY A QUALIFIED SPECIAL INSPECTIONS AGENCY. 10. AT THE COMPLETION OF FABRICATION, REGISTERED AND APPROVED FABRICATORS SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE OWNER OR THE OWNER'S AUTHORIZED AGENT FOR SUBMITTAL TO THE BUILDING OFFICIAL STATING THAT THE WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. SOILS (2018 NCSBC TABLE 1705.6) REQUIRED TYPE FREQUENCY YES 1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY.PERIODIC YES 2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL. PERIODIC YES 3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.PERIODIC YES 4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESS DURING PLACEMENT AND COMPACTION OF COMPACTED FILL.CONTINUOUS YES 5. PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY.PERIODIC CONCRETE (2018 NCSBC TABLE 1705.3) REQUIRED TYPE FREQUENCY REF. STANDARD IBC REF. YES 1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS, AND VERIFY PLACEMENT.PERIODIC ACI 318: CH. 20, 25.2, 25.3, 26.6.1-26.6.3 1908.4 NO 2. REINFORCING BAR WELDING: NO A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706.PERIODIC AWS D1.4 ACI 318: 26.6.4 -NO B. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16"; AND PERIODIC NO C. INSPECT ALL OTHER WELDS.CONTINUOUS YES 3. INSPECT ANCHORS CAST IN CONCRETE.PERIODIC ACI 318: 17.8.2 - YES 4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS. NO A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS.CONTINUOUS ACI 318: 17.8.2.4 YES B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.A.PERIODIC ACI 318: 17.8.2 - YES 5. VERIFY USE OF REQUIRED MIX DESIGN.PERIODIC 1904.1, 1904.2, 1908.2, 1908.3 ACI 318: CH. 19, 26.4.3, 26.4.4 YES 6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE CONCRETE. CONTINUOUS ASTM C172 ASTM C31 ACI 318: 26.5, 26.12 1908.10 YES 7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.CONTINUOUS ACI 318: 26.5 1908.6, 1908.7, 1908.8 YES 8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.PERIODIC 1908.9ACI 318: 26.5.3-26.5.5 NO 9. INSPECT PRESTRESSED CONCRETE FOR: NO A. APPLICATION OF PRESTRESSING FORCES; AND CONTINUOUS ACI 318: 26.10NO B. GROUTING OF BONDED PRESTRESSING TENDONS. CONTINUOUS - NO 10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS.PERIODIC ACI 318: CH. 26.9 - YES 11. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM BEAMS AND STRUCTURAL SLABS. PERIODIC ACI 318: 26.11.2 - YES 12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED.PERIODIC -ACI 318: 26.11.1.2(b) MASONRY (2018 IBC 1705.4) YES 1. AS MASONRY CONSTRUCTION BEGINS, THE FOLLOWING SHALL BE VERIFIED TO ENSURE COMPLIANCE: YES A. PROPORTIONS OF SITE-PREPARED MORTAR PERIODIC ART. 2.1, 2.6A, 2.6C NO B. GRADE AND SIZE OF PRESTRESSING TENDONS AND ANCHORAGE PERIODIC ART. 2.4B, 2.4H YES C. GRADE, TYPE AND SIZE OF REINFORCEMENT, CONNECTORS, ANCHOR BOLTS, AND PRESTRESSING TENDONS AND ANCHORAGES PERIODIC ART. 3.4, 3.6A NO D. PRESTRESSING TECHNIQUE PERIODIC ART. 3.6B NO E. PROPERTIES OF THIN-BED MORTAR FOR AAC MASONRY SEE NOTE (A) ART. 2.1C.1 YES 2. PRIOR TO GROUTING, VERIFY THAT THE FOLLOWING ARE IN COMPLIANCE: YES A. GROUT SPACE PERIODIC ART. 3.2D, 3.2F B. PLACEMENT OF PRESTRESSING TENDONS AND ANCHORAGESNO PERIODIC SEC. 10.8, 10.9 ART. 2.4, 3.6 YES C. PLACEMENT OF REINFORCEMENT, CONNECTORS, AND ANCHOR BOLTS PERIODIC ART. 3.2E, 3.4 YES D. PROPORTIONS OF SITE-PREPARED GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS PERIODIC ART. 2.6B, 2.4G.1.B SEC. 6.1, 6.3.1, 6.3.6, 6.3.7 YES 3. VERIFY COMPLIANCE OF THE FOLLOWING DURING CONSTRUCTION: YES C. SIZE AND LOCATION OF STRUCTURAL MEMBERS PERIODIC ART. 3.3F D. TYPE, SIZE AND LOCATION OF ANCHORS, INCLUDING OTHER DETAILS OF ANCHORAGE OF MASONRY TO STRUCTURAL MEMBERS, FRAMES, OR OTHER CONSTRUCTION YES PERIODIC SEC. 1.2.1(E), 6.2.1, 6.3.1 NO E. WELDING OF REINFORCEMENT CONTINUOUS SEC. 6.1.6.1.2 F. PREPARATION, CONSTRUCTION, AND PROTECTION OF MASONRY DURING COLD WEATHER (<40°F) OR HOT WEATHER (>90°F) YES PERIODIC ART. 1.8C,1.8D NO G. APPLICATION AND MEASUREMENT OF PRESTRESSING FORCE CONTINUOUS ART. 3.6B YES H. PLACEMENT OF GROUT AND PRESTRESSING GROUT FOR BONDED TENDONS IS IN COMPLIANCE CONTINUOUS ART. 3.5, 3.6C NO I. PLACEMENT OF AAC MASONRY UNITS AND CONSTRUCTION OF THIN-BED MORTAR JOINTS SEE NOTE (A) ART. 3.3B.9, 3.3F.1B 4. OBSERVE PREPARATION OF GROUT SPECIMENS, MORTAR SPECIMENS, AND/OR PRISMSYES PERIODIC ART. 1.4B.2.A.3, 1.4B.2.B.3, 1.4B.2.C.3, 1.4B.3, 1.4B.4 (A) CONTINUOUS REQUIRED FOR THE FIRST 5000 FT² OF AAC MASONRY AND PERIODIC REQUIRED AFTER THE FIRST 5000 FT² OF AAC MASONRY. LEVEL 2 MINIMUM SPECIAL INSPECTIONS (TMS402/602-16: TABLE 4) REFERENCE FOR CRITERIA TMS 402 TMS 602 REQUIRED INSPECTION TASK FREQUENCY NO F. SAMPLE PANEL CONSTRUCTION PERIODIC ART. 1.6D YES A. MATERIALS AND PROCEDURES WITH THE APPROVED SUBMITTALS PERIODIC ART. 1.5 YES B. PLACEMENT OF MASONRY UNITS AND MORTAR JOINT CONSTRUCTION PERIODIC ART. 3.3B MASONRY CONT. (2018 IBC 1705.4) LEVEL 2 MINIMUM VERIFICATIONS (TMS402/602-16: TABLE 3) YES 1. PRIOR TO CONSTRUCTION, VERIFY COMPLIANCE OF SUBMITTALS N/A ART. 1.5 REFERENCE FOR CRITERIA TMS 402 TMS 602 REQUIRED INSPECTION TASK FREQUENCY YES 2. PRIOR TO CONSTRUCTION, VERIFY F'M AND F'AAC, EXCEPT WHERE SPECIFICALLY EXEMPTED BY THE CODE N/A ART. 1.4B 3. DURING CONSTRUCTION, VERIFY SLUMP FLOW AND VISUAL STABILITY INDEX (VSI) WHEN SELF-CONSOLIDATING GROUT IS DELIVERED TO THE PROJECT SITE YES N/A ART. 1.5, 1.6.3 NO 4. DURING CONSTRUCTION, VERIFY F'M AND F'AAC FOR EVERY 5000 FT2 N/A ART. 1.4B 5. DURING CONSTRUCTION, VERIFY PROPORTIONS OF MATERIALS AS DELIVERED TO THE PROJECT SITE FOR PREMIXED OR PREBLENDED MORTAR, PRESTRESSING GROUT, AND GROUT OTHER THAN SELF-CONSOLIDATING GROUT NO N/A ART. 1.4B STRUCTURAL STEEL (2018 IBC 1705.2.1) INSPECTION OF WELDING INSPECTION TASKS PRIOR TO WELDING (AISC 360-16: TABLE N5.4-1) REQUIRED INSPECTION TASK FREQUENCY (A)(B)DESCRIPTION 2. WELDING PROCEDURE SPECIFICATIONS (WPSS) AVAILABLEYES PERFORM 3. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLEYES PERFORM YES 4. MATERIAL IDENTIFICATION (TYPE/GRADE) OBSERVE THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR MEMBER CAN BE IDENTIFIEDOBSERVE5. WELDER IDENTIFICATION SYSTEMYES STAMPS, IF USED, SHALL BE THE LOW-STRESS TYPE JOINT PREPARATION CLEANLINESS (CONDITION OF STEEL SURFACES) TACKING (TACK WELD QUALITY AND LOCATION) BACKING TYPE AND FIT (IF APPLICABLE) DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL) OBSERVE6. FIT-UP GROOVE WELDS (INCLUDING JOINT GEOMETRY)YES YES 8. CONFIGURATION AND FINISH OF ACCESS HOLES OBSERVE DIMENSIONS (ALIGNMENT, GAPS AT ROOT) CLEANLINESS (CONDITION OF STEEL SURFACES) TACKING (TACK WELD QUALITY AND LOCATION) OBSERVE9. FIT-UP FILLET WELDSYES INSPECTION TASKS DURING WELDING (AISC 360-16: TABLE N5.4-2) REQUIRED INSPECTION TASK FREQUENCY (A)(B)DESCRIPTION PACKAGING EXPOSURE CONTROL 1. CONTROL AND HANDLING OF WELDING CONSUMABLESYES OBSERVE YES 2. NO WELDING OVER CRACKED TACK WELDS OBSERVE WIND SPEED WITHIN LIMITS PRECIPITATION AND TEMPERATURE 3. ENVIRONMENTAL CONDITIONSYES OBSERVE SETTINGS ON WELDING EQUIPMENT TRAVEL SPEED SELECTED WELDING MATERIALS SHIELDING GAS TYPE/FLOW RATE PREHEAT APPLIED INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.) PROPER POSITION (F, V, H, OH) YES 4. WELDING PROCEDURES SPECIFICATION (WPS) FOLLOWED OBSERVE INTERPASS AND FINAL CLEANING EACH PASS WITHIN PROFILE LIMITATIONS EACH PASS MEETS QUALITY REQUIREMENTS YES 5. WELDING TECHNIQUES OBSERVE INSPECTION TASKS AFTER WELDING (AISC 360-16: TABLE N5.4-3) REQUIRED INSPECTION TASK FREQUENCY (A)(B)DESCRIPTION YES 1. WELDS CLEANED OBSERVE YES 2. SIZE, LENGTH, AND LOCATION OF WELDS PERFORM CRACK PROHIBITION WELD/BASE-METAL FUSION CRATER CROSS SECTION WELD PROFILES WELD SIZE UNDERCUT POROSITY YES 3. WELDS MEET VISUAL ACCEPTANCE CRITERIA PERFORM YES 4. ARC STRIKES PERFORM WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES, OR STIFFENERS HAS BEEN PERFORMED IN THE K-AREA, VISUALLY INSPECT THE WEB K-AREA FOR CRACKS WITHIN 3 IN. OF THE WELD. PERFORMYES 5. K-AREA 7. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)YES PERFORM YES 8. REPAIR ACTIVITIES PERFORM 9. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBERYES PERFORM INSPECTION TASKS PRIOR TO BOLTING (AISC 360-16: TABLE N5.6-1) REQUIRED INSPECTION TASK FREQUENCY (A)(B)DESCRIPTION INSPECTION OF BOLTING 1. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALSYES PERFORM 2. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTSYES OBSERVE 3. CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE) YES OBSERVE 4. CORRECT BOLTING PROCEDURE SELECTED FOR JOINT DETAILYES OBSERVE 7. CORRECT STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS, AND OTHER FASTENER COMPONENTSYES OBSERVE 5. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION AND HOLE PENETRATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS YES OBSERVE 6. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED. YES OBSERVE 1. WELDER QUALIFICATOIN RECORDS AND CONTINUITY RECORDSYES OBSERVE JOINT PREPARATION CLEANLINESS (CONDITION OF STEEL SURFACES) TACKING (TACK WELD QUALITY AND LOCATION) BACKING TYPE AND FIT (IF APPLICABLE) DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL) OBSERVE 7. FIT-UP CJP GROOVE WELDS OF HSS T-, Y-, AND K- JOINTS WITHOUT BACKING (INLUDING JOINT GEOMETRY) YES 6. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORSYES PERFORM 6. WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPESYES PERFORM 10. NO PROHIBITED WELDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF THE EORYES OBSERVE INSPECTION TASKS DURING BOLTING (AISC 360-16: TABLE N5.6-2) REQUIRED INSPECTION TASK FREQUENCY (A)(B)DESCRIPTION 1. FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND WASHERS (IF REQUIRED) ARE POSITIONED AS REQUIRED YES OBSERVE 2. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO PRETENSIONING OPERATIONYES OBSERVE 3. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATINGYES OBSERVE 4. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE EDGES YES OBSERVE INSPECTION TASKS AFTER BOLTING (AISC 360-16: TABLE N5.6-3) REQUIRED INSPECTION TASK FREQUENCY (A)(B)DESCRIPTION 1. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONSYES PERFORM OTHER INSPECTION TASKS (AISC 360-16: N5.8) REQUIRED INSPECTION TASK FREQUENCY (A)(B)DESCRIPTION AS A MINIMUM, THE DIAMETER, GRADE, TYPE, AND LENGTH OF THE ANCHOR ROD OR EMBEDDED ITEM, AND THE EXTENT OR DEPTH OF EMBEDMENT INTO THE CONCRETE, SHALL BE VERIFIED PRIOR TO PLACEMENT OF CONCRETE PERFORM 1. VERIFY PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING STRUCTURAL STEEL ARE IN COMPLIANCE WITH CONSTRUCTION DOCUMENTS YES BRACES STIFFENERS MEMBER LOCATIONS PROPER APPLICATION OF JOINT DETAILS AT EACH CONNECTION OBSERVE 2. INSPECT THE FABRICATED STEEL OR ERECTED STEEL FRAME, AS APPROPRIATE, TO VERIFY COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS YES (A) OBSERVE - OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS. (B) PERFORM - PERFORM THESE TASKS FOR EACH CONNECTION. INSPECTION OF GALVANIZED STRUCTURAL STEEL MAIN MEMBERS (AISC 360-16: N5.7) REQUIRED INSPECTION TASK FREQUENCY (A)(B)DESCRIPTION 1. VISUALLY INSPECT CUT SURFACES OF GALVANIZED STRUCTURAL STEEL MAIN MEMBERS AND EXPOSED CORNERS OF RECTANGULAR HSS'S FOR CRACKS SUBSEQUENT TO GALVANIZING YES PERFORM STRUCTURAL STEEL CONT. (2018 IBC 1705.2.1)UNCOATED BARSBAR SIZE LAP CLASS #3 A 1. LENGTHS SHOWN ARE BASED ON GRADE 60 REINFORCING BARS AND NORMAL-WEIGHT CONCRETE. FOR LIGHTWEIGHT AGGREGATE CONCRETE MULTIPLY LENGTHS BY 1.3. 2. FOR BEAMS AND COLUMNS, CASE 1 IS DEFINED AS MEMBERS HAVING COVER AT LEAST (1) BAR DIAMETER AND A CENTER-TO-CENTER SPACING AT LEAST (2) BAR DIAMETERS AND CASE 2 IS DEFINED AS MEMBERS HAVING COVER LESS THAN (1) BAR DIAMETER OR A CENTER-TO-CENTER SPACING LESS THAN (2) BAR DIAMETERS. 3. FOR ALL MEMBERS EXCEPT BEAMS AND COLUMNS, CASE 1 IS DEFINED AS MEMBERS HAVING COVER AT LEAST (1) BAR DIAMETER AND A CENTER-TO-CENTER SPACING AT LEAST (3) BAR DIAMETERS AND CASE 2 IS DEFINED AS MEMBERS HAVING COVER LESS THAN (1) BAR DIAMETER OR A CENTER-TO-CENTER SPACING LESS THAN (3) BAR DIAMETERS. 4. LAP CLASS A LENGTHS ARE REQUIRED TENSION DEVELOPMENT LENGTHS, Ld. 5. LAP SPLICE LENGTHS ARE MULTIPLES OF TENSION DEVELOPMENT LENGTHS; CLASS A = 1.0Ld AND CLASS B = 1.3Ld. 6. "TOP BARS" ARE DEFINED PER ACI AS HORIZONTAL REINFORCEMENT PLACED SO THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE DEVELOPMENT LENGTH OR SPLICE. 7. "OTHER BARS" ARE ALL BARS THAT ARE NOT DEFINED AS "TOP BARS" PER NOTE 6. 8. WHEN TENSION LAPPING A SMALLER DIAMETER BAR WITH A LARGER DIAMETER BAR, USE THE LAP LENGTH OF THE LARGER BARS. f'c = 3500 psi TOP BARS OTHER BARS CASE 1 CASE 2 CASE 1 CASE 2 #4 #5 #6 #7 #8 #9 #10 #11 B A B A B A B A B A B A B A B A B f'c = 4500 psi TOP BARS OTHER BARS CASE 1 CASE 2 CASE 1 CASE 2 f'c = 5000 psi TOP BARS OTHER BARS CASE 1 CASE 2 CASE 1 CASE 2 f'c = 6000 psi TOP BARS OTHER BARS CASE 1 CASE 2 CASE 1 CASE 2 18" 23" 23" 30" 29" 38" 35" 45" 51" 66" 58" 76" 66" 85" 74" 96" 82" 107" 26" 34" 35" 45" 44" 57" 52" 68" 76" 99" 87" 114" 98" 128" 111" 144" 123" 160" 14" 18" 18" 23" 22" 29" 27" 35" 39" 51" 45" 58" 51" 66" 57" 74" 63" 82" 20" 26" 27" 35" 34" 44" 40" 52" 59" 76" 67" 87" 76" 99" 85" 111" 95" 123" 20" 30" 15" 23" 26" 39" 20" 30" 26" 40" 20" 31" 34" 52" 26" 40" 33" 50" 25" 38" 43" 64" 33" 50" 40" 59" 31" 46" 52" 77" 40" 60" 58" 87" 44" 67" 75" 113" 58" 87" 66" 99" 51" 76" 86" 129" 66" 99" 74" 112" 57" 86" 97" 145" 75" 112" 84" 126" 65" 97" 109" 163" 84" 126" 93" 140" 72" 107" 121" 181" 93" 140" 17" 22" 22" 29" 28" 36" 33" 43" 48" 63" 55" 72" 62" 81" 70" 91" 78" 101" 25" 32" 33" 43" 41" 54" 50" 65" 72" 94" 83" 108" 93" 122" 105" 137" 117" 152" 13" 17" 17" 22" 21" 28" 26" 33" 37" 48" 43" 55" 48" 62" 54" 70" 60" 78" 19" 25" 26" 33" 32" 42" 38" 50" 56" 73" 64" 83" 72" 93" 81" 105" 90" 117" 15" 20" 20" 26" 25" 33" 30" 39" 44" 57" 50" 66" 57" 74" 64" 83" 71" 92" 23" 30" 30" 39" 38" 49" 45" 59" 66" 86" 76" 98" 85" 111" 96" 125" 107" 139" 12" 15" 16" 20" 19" 25" 23" 30" 34" 44" 39" 51" 44" 57" 49" 64" 55" 71" 18" 23" 23" 30" 29" 38" 35" 45" 51" 66" 58" 76" 66" 85" 74" 96" 82" 107" TENSION DEVELOPMENT AND LAP SPLICE LENGTHS TYPICAL FRAMING ATTACHMENT SCHEDULE CONNECTION DESCRIPTION ATTACHMENT LOCATION ROOF ROOF TRUSS OR RAFTER TO TOP PLATE - SPAN PERPENDICULAR TO WALL (3) 10d TOENAIL, EACH BEARING POINT BRIDGING OR BRACING TO TRUSS (2) 10d FACE NAIL, EACH TRUSS BLOCKING BETWEEN RAFTERS OR TRUSSES (3) 10d TOENAIL, EACH END BUILT-UP ROOF GIRDER TRUSS PER TRUSS MANUFACTURER WALL TOP PLATE TO TOP PLATE 10d AT 12" O.C. FACE NAIL TOP PLATE LAP AT CORNER OR INTERSECTION (4) 10d FACE NAIL BUILT-UP HEADER OR BEAM SEE WOOD HEADER/BEAM LEGEND CONTINUOUS HEADER TO STUD (4) 10d TOENAIL STUD TO STUD 10d AT 12" O.C. FACE NAIL, EACH STUD STUD TO STUD AT INTERSECTION OR CORNER 10d AT 12" O.C. FACE NAIL BUILT-UP WOOD POST, CHORD STUD OR JACK AND KING STUDS SEE BUILT-UP WOOD POST DETAIL BLOCKING BETWEEN STUDS (2) 10d TOENAIL, EACH END (4) 10d TOENAIL (3) 12d END NAIL STUD TO TOP OR BOTTOM PLATE BOTTOM PLATE TO RIBBON, TRUSS, JOIST, BLOCKING OR RIM JOIST 12d AT 12" O.C. FACE NAIL FLOOR FLOOR TRUSS OR JOIST TO TOP PLATE - SPAN PERPENDICULAR TO WALL (3) 10d TOENAIL, EACH BEARING POINT BLOCKING BETWEEN JOISTS OR TRUSSES (2) 10d TOENAIL, EACH END RIBBON TO TRUSS (3) 12d FACE NAIL, EACH TRUSS BUILT-UP FLOOR GIRDER TRUSS PER TRUSS MANUFACTURER 1. TYPICAL ATTACHMENTS SHALL BE APPLIED THROUGHOUT THE BUILDING EXCEPT WHERE DIFFERENT ATTACHMENTS ARE SPECIFIED ON PLANS OR DETAILS. JOISTS TO RIM JOIST (4) 10d FACE NAIL, EACH JOIST RIM JOIST TO TOP PLATE 10d AT 6" O.C. TOENAIL BOTTOM PLATE TO RIBBON, TRUSS, JOIST, BLOCKING OR RIM JOIST AT SHEAR WALLS 12d AT 3" O.C. FACE NAIL LADDER FLOOR TRUSS TO TOP PLATE 12d AT 12" O.C. FACE NAIL LADDER FLOOR TRUSS TO TOP PLATE AT SHEAR WALL 12d AT 3" O.C. FACE NAIL TYPICAL SHEATHING ATTACHMENT SCHEDULE LOCATION SHEATHING ATTACHMENT ROOF 1. REFERENCE DIVISION 06 - WOOD FRAMING NOTES FOR SHEATHING TYPES. 2. SEE PLANS AND SHEAR WALL SHEATHING SCHEDULE FOR LOCATIONS WHERE TYPICAL ATTACHMENT DOES NOT APPLY. 3. GYPSUM WALLBOARD SHEATHING AT INTERIOR WALLS SHALL BE ATTACHED PER ARCH/UL REQUIREMENTS UNLESS NOTED OTHERWISE ON SHEAR WALL SHEATHING SCHEDULE. ATTACH TO ROOF FRAMING MEMBERS WITH 0.131"x2½" RING SHANK NAILS AT 6" O.C. AT PANEL EDGES AND 12" O.C. AT PANEL FIELD. FLOOR ATTACH TO FLOOR FRAMING MEMBERS WITH CONSTRUCTION ADHESIVE AND 8d COMMON NAILS AT 6" O.C. AT PANEL EDGES AND 12" O.C. AT PANEL FIELD. WALL - EXTERIOR ATTACH TO WALL FRAMING MEMBERS WITH 8d COMMON OR GALVANIZED BOX NAILS AT 6" O.C. AT PANEL EDGES AND 12" O.C. AT PANEL FIELD. ALL PANEL EDGES SHALL BE BLOCKED. FRAMING NAILS SCHEDULE PENNYWEIGHT DIAMETER LENGTH HEAD DIAMETER 8d 0.131" 2½" 0.281" 10d 0.148" 3" 0.312" 12d 0.148" 3¼" 0.312" 16d 0.162" 3½" 0.344" 1. SCHEDULE INDICATES DIMENSIONS FOR STANDARD COMMON STEEL WIRE NAILS PER NDS TABLE L4. 4" MASONRY LOOSE LINTEL SCHEDULE OPENING SIZE 1. REFERENCE DIVISION 05 - STEEL NOTES FOR ANGLE PROPERTIES. 2. LINTELS SHALL BE GALVANIZED OR UTILIZE AN APPROVED PROTECTIVE COATING PRIOR TO INSTALLATION. 3. PROVIDE MINIMUM 6" BEARING ON EACH END. UP TO 4'-0" 4'-1" TO 5'-6" 5'-7" TO 7'-6" 7'-7" TO 9'-6" SIZE L3 x 3½ x ¼ L4 x 3½ x ⁵/₁₆ L5 x 3½ x ⁵/₁₆ L6 x 3½ x ⁵/₁₆ ORIENTATION LONG LEG HORIZONTAL LONG LEG VERTICAL LONG LEG VERTICAL LONG LEG VERTICAL WOOD FRAMING SHRINKAGE AND SETTLEMENT SCHEDULE FRAMED LEVEL TOTAL MOVEMENT 1. ANTICIPATED MOVEMENT PROVIDED IS BASED ON DESIGN SHRINKAGE OF SPECIFIED LUMBER AND TYPICAL TOLERANCES IN WOOD CONSTRUCTION. 2. SITE CONDITIONS, WEATHER, AND FRAMING PRACTICES MAY AFFECT ACTUAL TOTAL MOVEMENT. 3. M/E/P CONTRACTORS SHALL ACCOUNT FOR MOVEMENT WITH THE USE OF FLEXIBLE JOINTS OR OTHER APPROVED CONSTRUCTION METHODS. SECOND THIRD FOURTH FIFTH ROOF 3/8" 5/8" 7/8" 1⅛" 1⅜" WOOD HEADER/BEAM LEGEND MARK MARKSIZE SIZE 2-26 2-16 LVL(2) 2x6 (2) 1¾"x16" LVL 3-26 3-16 LVL(3) 2x6 (3) 1¾"x16" LVL 2-28 2-18 LVL(2) 2x8 (2) 1¾"x18" LVL 3-28 3-18 LVL(3) 2x8 (3) 1¾"x18" LVL 2-210 2-20 LVL(2) 2x10 (2) 1¾"x20" LVL 3-210 3-20 LVL(3) 2x10 (3) 1¾"x20" LVL 2-212 410 PSL(2) 2x12 3½"x9½" PSL 3-212 610 PSL(3) 2x12 5¼"x9½" PSL 2-8 LVL 412 PSL(2) 1¾"x7¼" LVL 3½"x11⅞" PSL 3-8 LVL 612 PSL(3) 1¾"x7¼" LVL 5¼"x11⅞" PSL 2-10 LVL 414 PSL(2) 1¾"x9½" LVL 3½"x14" PSL 3-10 LVL 614 PSL(3) 1¾"x9½" LVL 5¼"x14" PSL 2-12 LVL 416 PSL(2) 1¾"x11⅞" LVL 3½"x16" PSL 3-12 LVL 616 PSL(3) 1¾"x11⅞" LVL 5¼"x16" PSL 2-14 LVL 418 PSL(2) 1¾"x14" LVL 3½"x18" PSL 3-14 LVL 618 PSL(3) 1¾"x14" LVL 5¼"x18" PSL 1. ALL PLIES OF HEADERS/BEAMS SHALL BE CONTINUOUS BETWEEN SUPPORT POINTS. 2. HEADERS/BEAMS SHALL BEAR EVENLY ACROSS THE FULL WIDTH OF SUPPORTS UNLESS DETAILED OTHERWISE. 3. HEADER/BEAM PLIES SHALL BE ATTACHED TOGETHER AS INDICATED BELOW. NAILS SHALL BE STAGGERED ON OPPOSITE SIDES OF (3) PLY MEMBERS. LOCATE TOP AND BOTTOM ROWS 2" FROM OUTER EDGES. NOMINAL MEMBER DEPTH < 10": (2) ROWS OF 10d NAILS AT 6" O.C. NOMINAL MEMBER DEPTH ≥ 10": (3) ROWS OF 10d NAILS AT 6" O.C. SILL PLATE ATTACHMENT SCHEDULE LOCATION EXTERIOR WALL - TYPICAL POST INSTALLED CAST-IN-PLACE 1/2" Ø x 6" LONG SIMPSON 'TITEN HD' SCREW AT 4'-0" O.C.SIMPSON 'MASA' STRAPS AT 4'-0" O.C. EXTERIOR WALL - SHEAR WALL (4)1/2" Ø x 6" LONG SIMPSON 'TITEN HD' SCREW AT 2'-0" O.C. INTERIOR WALL - TYPICAL SIMPSON 'PDPAWL-287' POWDER ACTUATED FASTENERS AT 4'-0" O.C.1/2" Ø ANCHOR BOLTS AT 4'-0" O.C. INTERIOR WALL - SHEAR WALL (4)1/2" Ø x 6" LONG SIMPSON 'TITEN HD' SCREW AT 2'-0" O.C.1/2" Ø ANCHOR BOLTS AT 2'-0" O.C. 1. MAINTAIN A 4" MINIMUM AND 12" MAXIMUM DISTANCE FROM ENDS OF PLATES AT CORNERS AND SPLICES. 2. ANCHOR BOLTS, SCREWS, AND POWDER ACTUATED FASTENERS SHALL BE INSTALLED ALONG THE CENTERLINE OF THE PLATES. 3. ANCHOR BOLTS SHALL HAVE A MINIMUM 6" EMBENDMENT AND SHALL UTILIZE A STANDARD CUT WASHER. 4. PROVIDE SIMPSON 'BPS½-6' BEARING PLATE AT 2x6 SHEAR WALLS AND 'BPS½-3' BEARING PLATE AT 2x4 SHEAR WALLS. UTILIZE SLOTTED HOLES IN BEARING PLATE TO MAINTAIN 1/2" MAXIMUM DISTANCE FROM EDGE OF PLATE TO FACE OF SILL PLATE THAT CONTAINS SHEAR WALL SHEATHING. 1/2" Ø ANCHOR BOLTS AT 2'-0" O.C. CONCRETE MASONRY UNIT LINTEL AND JAMB SCHEDULE WALL THICKNESS 1. GROUTED LINTEL SHALL EXTEND TO JAMB WIDTH INDICATED BEYOND OPENING. 2. PRECAST CONCRETE LINTELS OF SAME SIZE AND LENGTH MAY BE SUBSTITUTED. REINFORCE TOP AND BOTTOM OF PRECAST LINTEL TO MATCH BOTTOM REINF. INDICATED IN SCHEDULE. 3. LINTELS TO BE CONSTRUCTED USING SOLID BOTTOM MASONRY UNITS. 4. WHEN (2)TWO BARS ARE INDICATED, LOCATE BARS 3/4" FROM INSIDE EDGE OF MASONRY UNIT WALL. MAX. OPENING SIZE LINTEL DEPTH AND JAMB WIDTH TOP REINF. BOTTOM REINF. 8" 4'-0" 8" (1)#4 (1)#4 8" 6'-0" 8" (1)#4 8" 8'-0" 16" (2)#4 8" 10'-0" 16" 12" 4'-0" 8"(2)#4 12" 12" 12" 6'-0" 8'-0" 10'-0" 8" 16" 16"(2)#5 (2)#5 (2)#5 (2)#4 (2)#4 (2)#4 (2)#4 (2)#4 (2)#4 (2)#4 (2)#4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:19 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS00.02 Author Checker DDS-025-22 GENERAL SCHEDULES AND SPECIAL INSPECTIONS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:19 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS00.03 Author Checker DDS-025-22 COUNTY SPECIAL INSPECTIONS FORMS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 2' - 0"1' - 0"2#4 CONTINUOUS SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT 2#4 CONTINUOUS SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT 2' - 0"1' - 0"1/2" ISOLATION JOIST ALTERNATE: THIS CAN BE SUBSTITUTED WITH AN 8" WIDE CONCRETE CURB WITH 1#4 CONTINUOUS BAR U.N.O. IN DETAILS OR ON PLAN, PROVIDE #5 BARS AT 48" O.C. IN FULLY GROUTED CELLS W/ HORIZ. JOINT REINF AT EVERY OTHER COURSE. AT CRASH WALL LOCATIONS, PROVIDE #5 BARS AT 8" O.C. IN FULLY GROUTED CELLS UP TO 3'-0" ABOVE PARKING SLAB 2' - 0" 2#4 CONTINUOUS SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT 8" 4"FOOTING DEPTHSEE PLAN/SECTIONSFOOTING STEPMINIMUM 2x FOOTING STEP SAME AS FOOTING DEPTH MAY SLOPE AS NECESSARY TO MAINTAIN STABLE SLOPE IN SOIL 'Z' BAR TO MATCH SIZE AND QUANTITY OF FOOTING BOTTOM BAR WITH STANDARD HOOK TOP AND BOTTOM NOTE: TRANSVERSE BARS, WHERE REQUIRED, NOT SHOWN FOR CLARITY.3"3" 2"2"FOOTING DEPTHSEE PLAN/SECTIONS2"EQ EQ EQ LONGITUDINAL REINFORCEMENT WHERE IT OCCURS NOTE: TRANSVERSE BARS, WHERE REQUIRED, NOT SHOWN FOR CLARITY. CLASS B TENSION LAP SPLICE SECOND POURFIRST POUR CONSTRUCTION JOINT CONTROL JOINT TONGUE AND GROOVE JOINT WITH BOND BREAKER OF EITHER CURING COMPOUND OR FORM OIL SAW CUT SLAB 1/4 OF SLAB DEPTH AS SOON AS CONCRETE HAS HARDENED SUFFICIENTLY TO NOT DAMAGE SLAB DURING CUTTING NOTE: 1. PROVIDE CONTROL OR CONSTRUCTION JOINTS AT 20'-0" ON CENTER MAXIMUM. PANELS LONG SIDE SHALL NOT EXCEED 1.5 TIMES THE SHORT SIDE. 2. SLAB ON GRADE REINFORCING SHALL BE PLACED IN THE UPPER THIRD OF THE SLAB AND SUPPORTED BY CHAIRS. 3. SEE PLAN FOR SLAB THICKNESS AND REINFORCING. 4. SEE SPECIFICATIONS FOR SLAB SUBGRADE AND VAPOR BARRIER REQUIREMENTS. PIN WHEEL DIAMOND 4"MIN CONTROL JOINT, SEE TYPICAL DETAIL 1/2" ISOLATION JOINT AROUND COLUMN SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT ≤ 1' - 0"1' - 0" 1.5 1 2' - 0"1' - 0"8" 1' - 0" < 3' - 6"SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT #4 DOWELS SPACED AT 18" O.C., ALTERNATE HOOK AND EXTEND 4" MINIMUM INTO SLAB #4 SPACED AT 12" O.C., PROVIDE MINIMUM 2#4 HORIZONTAL BARS 2#4 CONTINUOUS 1#4 CONTINUOUS BAR AT SLAB STEP 8" INSIDE/OUTSIDE CORNER INTERSECTION CONSTRUCTION JOINT VERTICAL CONSTRUCTION JOINT DOWELS TO MATCH HORIZONTAL BAR SIZE AND SPACING 3/4"x3/4" REGLET IN SURFACES EXPOSED TO VIEW ALTERNATE DIRECTION OF HOOK EVERY OTHER BAR NOTE: 1. PROVIDE 2x4 KEYED CONSTRUCTION JOINT IN CONCRETE WALLS AT 60'-0" ON CENTER AND AT CORNERS/INTERSECTIONS AS SHOWN. NO JOINTS PERMITTED WITHIN 5'-0" OF CORNERS OR WALL INTERSECTIONS. 2. PROVIDE FULL HEIGHT FORMED VERTICAL CONTROL JOINTS SPACED AT 1.5 TIMES THE TOTAL WALL HEIGHT AND NO MORE THE 20'-0" ON CENTER MAXIMUM. 3. WATERPROOFING AND WATERSTOP ARE NOT SHOWN AND SHALL BE COORDINATED WITH ARCHITECTURAL REQUIREMENTS. 4. FORM SAVER COUPLERS MAY BE USED. SUBMIT PRODUCT SPECIFICATIONS TO S.E.R. FOR APPROVAL.CLASS B TENSIONLAP SPLICECLASS B TENSION LAP SPLICE CLASS B TENSION LAP SPLICE CLASS B TENSION LAP SPLICE CLASS B TENSION LAP SPLICE CLASS B TENSIONLAP SPLICEEQ EQ EQ INSIDE/OUTSIDE CORNER INTERSECTION CONSTRUCTION JOINT VERTICAL CONSTRUCTION JOINT DOWELS TO MATCH HORIZONTAL BAR SIZE AND SPACING CUT ALTERNATE BARS IN EACH FACE OF WALL, DO NOT CUT TOP OR BOTTOM MOST BARS 3/4"x3/4" REGLET IN SURFACES EXPOSED TO VIEW NOTE: 1. PROVIDE 2x4 KEYED CONSTRUCTION JOINT IN CONCRETE WALLS AT 60'-0" ON CENTER AND AT CORNERS/INTERSECTIONS AS SHOWN. NO JOINTS PERMITTED WITHIN 5'-0" OF CORNERS OR WALL INTERSECTIONS. 2. PROVIDE FULL HEIGHT FORMED VERTICAL CONTROL JOINTS SPACED AT 1.5 TIMES THE TOTAL WALL HEIGHT AND NO MORE THE 20'-0" ON CENTER MAXIMUM. 3. WATERPROOFING AND WATERSTOP ARE NOT SHOWN AND SHALL BE COORDINATED WITH ARCHITECTURAL REQUIREMENTS. 4. FORM SAVER COUPLERS MAY BE USED. SUBMIT PRODUCT SPECIFICATIONS TO S.E.R. FOR APPROVAL. CLASS B TENSION LAP SPLICE CLASS B TENSION LAP SPLICE CLASS B TENSION LAP SPLICE CLASS B TENSION LAP SPLICE CLASS B TENSIONLAP SPLICECLASS B TENSIONLAP SPLICEEQ EQ EQ OPENING PROVIDE ADDITIONAL VERTICAL BAR EACH SIDE OF OPENING FULL HEIGHT OF WALL 4'-0" LONG #4 DIAGONAL BAR, TYPICAL EACH CORNER PROVIDE ADDITIONAL HORIZONTAL BAR ABOVE AND BELOW OPENING 2' - 6" MIN (TYP) NOTE: 1. PROVIDE (1) ADDITIONAL BAR WHEN SINGLE LAYER REINFORCING IS USED IN WALL. 2. PROVIDE (1) ADDITIONAL BAR IN EACH FACE WHEN DOUBLE LAYER REINFORCING IS USED IN WALL.2' - 0" MAX2' - 0" MAX #4 SPACED AT 12" O.C. EACH WAY PLACED AT MID-DEPTH SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT MECHANICAL EQUIPMENT 6"6" MIN UNREINFORCED CMU WALL SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT NOTE: UNREINFORCED, NON-BEARING CMU WALL SHALL NOT EXCEED 12'-0" IN HEIGHT. 8#8 VERTICAL BARS WITH #3 TIES SPACED AT 10" O.C. 6#8 VERTICAL BARS WITH #3 TIES SPACED AT 10" O.C. NOTES: 1. TYPICAL WALL REINFORCING NOT SHOWN FOR CLARITY. 2. VERTICAL BARS AND TIES SHALL EXTEND DOWN FROM UPPER WALLS THROUGH LOWER WALLS TO FOOTING. END WALL/OPENING/ INTERSECTION DOWEL OR LOWER SPLICED BAR, TYPICAL 135° AT TIES, TYPICAL CORNER DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:22 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS01.11 MG,GK,MS MJS DDS-025-22 TYPICAL FOUNDATION DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"10 TYPICAL REINFORCED CMU WALL FOUNDATION 3/4" = 1'-0"1 TYPICAL FOOTING STEP 3/4" = 1'-0"2 TYPICAL FOOTING CONSTRUCTION JOINT 3/4" = 1'-0"3 TYPICAL SLAB ON GRADE JOINTS 3/4" = 1'-0"4 CONCRETE COLUMN ISOLATION JOINT 3/4" = 1'-0"5 TYPICAL SLAB ON GRADE STEP 3/4" = 1'-0"6 TYPICAL CONCRETE WALL INTERSECTIONS 3/4" = 1'-0"7 TYPICAL CONCRETE WALL INTERSECTIONS 3/4" = 1'-0"8 TYPICAL WALL OPENING 3/4" = 1'-0"9 TYPICAL EQUIPMENT PAD 3/4" = 1'-0"11 TYPICAL NON-BEARING INTERIOR CMU WALL 3/4" = 1'-0"12 CORNER REINFORCEMENT - STAIR / ELEVATOR WALLS DATE DESCRIPTION REV THICKENED SLAB AT ELEVATOR ENTRANCE ELEVATOR OPENING ELEVATOR SILL, COORDINATE WITH MANUFACTURER TYPICAL EACH FLOOR. DOWELS TO MATCH VERTICAL BARS. 2'-0" x 2'-0" x 2'-0" DEEP SUMP PIT THICKENED SLAB AT SUMP. PROVIDE (4) #4 E.W. MAINTAIN 8" MIN. THICKNESS SLAB ON GRADE, SEE PLAN FOR REINFORCEMENT 10" CONCRETE WALL WITH #5 AT 12" O.C. EACH FACE EL. SEE PLAN 8"10"12"SEE PLANFOR THICKNESSPOUR STARTER SLAB FOR PLACEMENT OF WATERPROOFING AS NEEDED 1"x2" KEYWAY WITH WATERSTOP TYP. SEE PLAN 1' - 8"SEE PLAN #6 BARS AT 12" O.C.E.W TOP & BOTTOM 2'-0" MIN. LAPSEE FOUNDATION PLAN FOR FOOTING SIZE AND REINF. #5 DOWELS ON EACH FACE TO MATCH VERTICAL BARS IN WALL W/ 12" HOOK INTO FOOTING 12" CONCRETE WALL W/ #5 VERTICAL BARS AT 12" O.C.E.F. AND #4 HORIZ BARS AT 16" O.C.E.F. SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT U.N.O. ON PLAN1' - 6" TYP.VARIES W/ RAMP SLOPE2'-0" MIN. LAPSEE FOUNDATION PLAN FOR FOOTING SIZE AND REINF. #5 DOWELS ON EACH FACE TO MATCH VERTICAL BARS IN WALL W/ 12" HOOK INTO FOOTING 10" CONCRETE WALL W/ #5 VERTICAL BARS AT 12" O.C.E.F. AND #4 HORIZ BARS AT 16" O.C.E.F. SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT #5 DOWELS SPACED AT 12" O.C. EACH FACE #4 AT 16" O.C. HORIZONTAL EACH FACE #5 AT 12" O.C. VERTICAL BARS SEE FOUNDATION PLAN FOR FOOTING SIZE AND REINF. #5 DOWEL INTO TOP OF WALL AT 16" O.C. 8'-0" 2'-0" 10"8"5"1' - 0"SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT REFER TO ARCHITECTURAL DRAWINGS FOR INSULATION REQUIREMENTS COLD FORMED STEEL EXTERIOR CURTAIN WALL BELOW DESIGNED BY OTHERS, COORD. WIDTH W/ ARCH PLANS 43mil (18ga.) #4 BARS AT 24" O.C. W/ #4 BAR CONTINUOUS AT BRICK LOCATIONS MIN.1' - 6"MIN. 1' - 6"(2)#4 BOTTOM BARS CONT. W/ MIN. 3" CLEAR COVER BRICK VENEER. COORDINATE LOCATION W/ ARCH DWGS. GROUT SOLID BEHIND BRICK BELOW GRADE AT LOCATIONS WITHOUT BRICK VENEER, FOOTING PROJECTION MAY BE ELIMINATED 10"8" #4 EDGE BAR CONT. GC OPTION TO USE A TWO- POUR SEQUENCE GC OPTION TO USE A THREE- POUR SEQUENCE. PROVIDE #4 DOWELS AT 24" O.C. INTO STEM WITH (2)#4 CONT. STOREFRONT FRAMING, BY OTHERS CURB AS NEEDED FOR STOREFRONT AS A SECONDARY POUR. PROVIDE WATERSTOP BETWEEN POURS AND PROVIDE 18" LONG #4 DOWELS AT 16" O.C. W/ (1)#4 CONT. NOTES: 1. SEE DETAIL 5 ON THIS SHEET FOR INFORMATION NOT SHOWN 2. REFER TO DETAIL 5 FOR TWO-POUR AND THREE-POUR SEQUENCE OPTIONS 12"x12"x5/8" STEEL BASE PLATE AND 1/4" LEVELING PLATE TO MATCH SIZE W/ (4)3/4" ANCHOR BOLTS ON 1/2" NON-SHRINK GROUT BED PROVIDE 16"x16"x4" DEEP BLOCKOUT AT STOREFRONT STEEL POST LOCATIONS. COORD. W/ ARCH STEEL POST, SEE PLAN NOTES: 1. SEE DETAIL 5 ON THIS SHEET FOR INFORMATION NOT SHOWN 2. REFER TO DETAIL 5 FOR TWO-POUR AND THREE-POUR SEQUENCE OPTIONS #5 DOWELS AT 32" O.C. IN FULLY GROUTED CELLS. 18" MIN. INTO FOUNDATION SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT TRENCH DRAIN BY OTHERS 1' - 0" 4" MIN6" MIN2#4 CONT. EACH SIDE OF TRENCH DRAIN 1' - 0" MIN ENTRY DRIVE AISLE ON GRADE, SEE CIVIL DRAWINGS #4 AT 16" O.C. 2' - 0" DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:22 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS01.12 MG,GK,MS MJS DDS-025-22 FOUNDATION DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"1 FOUNDATION - ELEVATOR PIT DETAIL 3/4" = 1'-0"2 FOUNDATION AT CONCRETE RAMP WALL 3/4" = 1'-0"3 FOUNDATION AT INTERIOR CONCRETE WALL 3/4" = 1'-0"4 FOUNDATION WALL AT LARGE STEP 3/4" = 1'-0"5 FOUNDATION - LIGHT GAUGE 3/4" = 1'-0"7 FOUNDATION AT STOREFRONT 3/4" = 1'-0"6 FOUNDATION AT EXTERIOR CMU WALL 3/4" = 1'-0"8 GARAGE TRENCH DRAIN DATE DESCRIPTION REV COLUMN VERTICAL BAR PER SCHEDULE, TYPICAL 135° ON COLUMN TIES, SEE SCHEDULE FOR SIZE AND SPACING DOWEL OR LOWER SPLICED BAR, TYPICAL COLUMN TIE SPACING TIE SIZE 3 6 4 10" 12" 14" 16" 18" 20"LEAST COLUMNFACE DIMENSIONVERTICAL BARS >22" 7 8 9 10 11 10" 10" 10" 10" 10" 10" 12" 14"12" 12" 12" 12" 12" 14" 14" 14" 14" 14" 14" 14" 14" 12" 12" 12" 12" 12" 16" 16" 16" 16" 16" 16" 16" 18" 18" 18" 18" 18" 18" 18" 20" 22" C-1 18"x30" W/ (12)#7 BARS C-2 24"x24" W/ (12)#8 BARS C-3 18"x30" W/ (12)#8 BARS ROTATED COLUMN ABOVE/BELOW PROVIDE STANDARD HOOK INTO SLAB DOWEL OR LOWER SPLICED BAR AT CENTER (6) BARS CABLE BARRIER, COORD. SPACING WITH MANUF. PROVIDE COLUMN TIE INDICATED BETWEEN EACH CABLE BARRIER SLEEVE C-3 COLUMN ONLY WHERE INDICATED ON PLAN GARAGE SLAB 30 BAR DIA.SEE COLUMN SCHEDULE FOR SIZE AND REINFORCING SEE PLAN AND FOOTING SCHEDULE FOR SIZE AND REINFORCING DOWELS TO MATCH VERTICAL COLUMN REINFORCING SIZE AND QUANTITY W/ STANDARD HOOK SEE COLUMN SCHEDULE FOR TIE SIZE AND SPACING 'S'3"3"3"3"SSSEE COLUMN SCHEDULE FOR SIZE AND REINFORCING SEE COLUMN SCHEDULE FOR TIE SIZE AND SPACING 'S'S 3" 3" 3" - CONSTRUCTION JOINT SHALL OCCUR AT BOTTOM OF SLAB PROVIDE AT LEAST 2 TIES MINIMUM AT SLAB EDGE AND CORNER CONDITION 3" MAX. FROM BEND IN VERTICAL BAR AND WITHIN S/2 OF SLAB BOTTOM BAR-30 BAR DIA. U.N.O. INCOLUMN SCHEDULE3"3"3"3"SNOTE: FOR 12 BAR CONFIGURATION - 6 BARS CONTINUE TO FLOOR ABOVE AND 6 BARS TERMINATE WITHIN SLAB. INVERT IMAGE FOR COLUMN BARS FROM ABOVE FLAT PLATE CONSTRUCTION JOINT SHALL OCCUR AT BOTTOM OF SLAB SEE CONCRETE COLUMN TIE SPACING SCHEDULE FOR TIE SIZE AND SPACING 'S' CONCRETE COLUMN, SEE SCHEDULE FOR SIZE AND REINFORCEMENT SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT 3"3"3"SCL PROVIDE (2) TIES MINIMUM AT SLAB EDGE AND CORNER CONDITION 3" 3" 3" 3" S30 BAR DIA MIN U.N.O.IN COLUMN SCHEDULE3" MAXIMUM FROM BEND IN VERTICAL BAR AND WITHIN S/2 OF SLAB BOTTOM BAR FLAT PLATE CONSTRUCTION JOINT SHALL OCCUR AT BOTTOM OF SLAB SEE CONCRETE COLUMN TIE SPACING SCHEDULE FOR TIE SIZE AND SPACING 'S' CONCRETE COLUMN, SEE SCHEDULE FOR SIZE AND REINFORCEMENT SEE PLAN FOR SLAB THICKNESS AND REINFORCEMENT DOWELS TO MATCH QUANTITY AND SIZE OF VERTICAL REINFORCEMENT WITH STANDARD HOOK INTO SLAB3"3"3"3"SSSCL CLASS B TENSIONLAP SPLICENOTE: DOWELS ARE NOT REQUIRED IF COLUMN VERTICAL BARS ARE CONTINUOUS AND HOOK INTO SLAB.3"PROVIDE (2) TIES MINIMUM AT SLAB EDGE AND CORNER CONDITION MAINTAIN COLUMN TIES AND VERTICAL REINFORCEMENT DOWN TO FOUNDATION ENGAGE WALL HORIZONTAL REINFORCEMENT BEHIND COLUMN VERTICAL BARS NOTE: SEE TIE AND REBAR REQUIREMENTS ON DETAIL 1 - SHEET S210 LINE OF COLUMN ABOVE CONT. FOUNDATION WALL SHIFT COLUMN REINFORCEMENT INTO WALL TO ALLOW WALL REINF. TO PASS THROUGH COLUMN. VERTICAL BARS FROM COLUMN ABOVE MAY BE INSIDE WALL RIENF. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:23 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS01.21 MG,GK,MS MJS DDS-025-22 CONCRETE COLUMN DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"1 COLUMN REINFORCING - TIE AND REBAR PLACEMENT 3/4" = 1'-0"2 TYPICAL CONCRETE COLUMN FOOTING 3/4" = 1'-0"5 COLUMN REINFORCING - ROTATED COLUMN 3/4" = 1'-0"4 COLUMN REINFORCING - INTERMEDIATE SLAB 3/4" = 1'-0"3 COLUMN REINFORCING - TOP OF COLUMN 3/4" = 1'-0"6 COLUMN - MONOLITHIC WITH FOUNDATION WALL DATE DESCRIPTION REV NOTES: 1. REFER TO PLANS FOR TENDON DRAPE DIMENSIONS. 2. MILD REINFORCING NOT SHOWN FOR CLARITY. SEE DETAIL X/SXXX FOR MILD REINFORCING PLACEMENT INFORMATION. 3. REFER TO DETAIL X/SXXX FOR ADDITIONAL REINFORCING REQUIRED AT ADD TENDON TERMINATION LOCATIONS. 4. COORDINATE ADDITIONAL BURSTING STEEL REQUIREMENTS WITH P/T SUPPLIER. CGS = CENTER OF GRAVITY OF POST-TENSIONING TENDON A = TENDON CGS AT EDGE OF SLAB B = TENDON CGS AT MIDSPAN (UNLESS NOTED OTHERWISE) C = TENDON CGS AT INTERIOR SUPPORT D = TENDON CGS AT SHORT SPAN HIGH POINT CL CL CL CL SEE PLAN L1 - END SPAN L2 - TYPICAL SPAN L3 - SHORT SPAN WITH NO MID-SPAN DRAPE L4 - CANTILEVER SPAN AL1/10 INFLECTION CGS= 0.2B + 0.8ABL1/10 INFLECTION CGS= 0.2B + 0.8CL2/10EQEQEND ANCHORAGE, REFER TO P/T ANCHORAGE DETAILS FOR ADDITIONAL INFORMATION TYPICAL POINT OF INFLECTION BL2/10EQEQ INFLECTION CGS= 0.2B + 0.8DADDED TENDON TERMINATION POINT L4/10 INFLECTION CGS= 0.2A + 0.8DAEQEQDCL CL SEE PLAN FOR COLUMN GRIDLINES CENTER BOTTOM BARS AT MID-SPAN U.N.O. ON PLAN SEE X/SXXX FOR BAR LOCATIONS OVER COLUMN DISCONTINUOUS SUPPORT CONTINUOUS SUPPORT NOTES: 1. POST-TENSIONING TENDONS NOT SHOWN FOR CLARITY. 2. REFER TO PLANS FOR REINFORCING SIZE AND SPACING REQUIREMENTS. 3. CENTER TOP BARS AT COLUMNS U.N.O. ON PLAN. 4. SPACE BARS AT COLUMNS EVENLY WITHIN THE 'A' STRIP U.N.O. ON PLAN, SEE X/SXXX. 5. PROVIDE STANDARD 90° HOOK AT END OF BENT BARS ON PLAN. (8) 5T x 12' - 0" QUANTITY BAR SIZE BAR LOCATION T = TOP B = BOTTOM BAR LENGTH BAR CALL-OUT NOMENCLATURE 1 1/2" DEEP KEYWAY, TYP BETWEEN PT TENDON ANCHORS A A B B2" TYP.EQT/3EQ"T"EQEQSECTION "A": TYPICAL BETWEEN TENDONS #4 TOP AND BOTTOM CONT. CONTINUE TOP AND/OR BOTTOM SLAB REINFORCEMENT THROUGH CONSTRUCTION JOINT, TYP."T"SECTION "B": TYPICAL AT TENDONS P/T TENDON#4 CONT. TOP AND BOTTOM TYP. 1 1/2"xT/3 CONT. KEYWAY, TYP. BETWEEN TENDONS AND ANCHORS #4x4'-0" AT 12" O.C. CONSTRUCTION JOINT INTERMEDIATE STRESSING ANCHORAGE, BY PT SUPPLIER, TO BE PLACED PERPENDICULAR TO TENDON PROFILE 1 1/2" DEEP KEYWAY, TYP BETWEEN PT TENDON ANCHORS A A B B2" TYP.EQT/3EQ"T"EQEQSECTION "A": TYPICAL BETWEEN TENDONS #4 TOP AND BOTTOM CONT. CONTINUE TOP AND/OR BOTTOM SLAB REINFORCEMENT THROUGH CONSTRUCTION JOINT, TYP."T"SECTION "B": TYPICAL AT TENDONS P/T TENDON#4 CONT. TOP AND BOTTOM TYP. 1 1/2"xT/3 CONT. KEYWAY, TYP. BETWEEN TENDONS AND ANCHORS CONSTRUCTION JOINT INTERMEDIATE STRESSING ANCHORAGE, BY PT SUPPLIER, TO BE PLACED PERPENDICULAR TO TENDON PROFILE3"CLEAR, TYP. #6x6'-0" AT 12" O.C. CHAIR, TYP.2" CLR MIN. UNIFORM TENDONS BOTTOM REINFORCEMENT, SEE PLAN BANDED TENDONS (1)#4 CONTINUOUS SUPPORT BAR, TYP. PROFILE HIGH POINT, SEE PLAN SUPPORT BAR OR SLAB BOLSTER @ 3' -0" O.C. MAX CANTILEVERED SPAN INTERIOR SPAN SHEAR WALL BAY CL STRESSING END KEEP TENDON STRAIGHT FOR 16" U.N.O. KEEP TENDON STRAIGHT FOR 16" U.N.O. LOW POINT, SEE PLAN HIGH POINT, SEE PLAN 'HARPED' STRAIGHT TENDON AT CANTILEVER, SEE PLAN WITH STRESSING L1 - EXTERIOR SPAN L2 - INTERIOR SPAN NO STRESSING L3 - EXTERIOR SPAN CL SPAN/4 MIN. STRESSING END CONTROL POINTS AS SHOWN ON PLAN STAGGER TERMINATED TENDONS AT 12" AT BANDS. ANCHOR AT NEUTRAL AXIS KEEP TENDON STRAIGHT FOR 16" U.N.O. KEEP TENDON STRAIGHT FOR 16" U.N.O.a TYP. NOTE: 'a' = 0.1*L FOR UNIFORM SLAB WITH NEUTRAL AXIS AT MID-DEPTH LOW POINT, SEE PLAN HIGH POINT, SEE PLAN 4 STRANDS MAX. PER BUNDLE SLAB EDGE NOTES: 1. STRANDS WITHIN A BUNDLE ARE TO BE SPACED AT 3" O.C. MIN. ALONG THE SLAB EDGE. 2. BUNDLES ARE TO BE SPACED 4" APART O.C. MIN. U.N.O. ON PLAN. 3. GROMMETS ARE TO BE USED ONLY AT THE STRESSING END. 36" MIN. STRAIGHT TOP AND BOTTOM BARS PER TYPICAL STRESSING END ANCHOR DETAIL CL HIGH POINT, SEE PLAN THROUGH TENDON #4x24" TOP AND BOTTOM, TIED TO ANCHORS STAGGER DEAD END ANCHORS AND PLACE HORIZONTAL IN SLABPLAN VIEW SECTION VIEW #4x2'-0" TOP AND BOTTOM OF ANCHORAGE, TYP. TIE TO ANCHORAGES TYPICAL SUPPORT CHAIR AND BAR THROUGH TENDONS 1 12 BANDED TENDONS, MAX. 4 PER BUNDLE DISTRIBUTED TENDONS SPACED AT 6x SLAB THICKNESS OR 48" O.C. MAX. THICKNESS ON EACH SIDE OF COLUMN MILD REINFORCEMENT TO 1.5 TIMES SLAB TOP REBAR, TYP. SPACED AT MAX 12" O.C. EACH WAY TOP REBAR, TYP. SPACED AT MAX 12" O.C. EACH WAY FOR 7" SLABS OR MORE, PLACE ANCHOR UPRIGHT AT 3" MIN. O.C. FOR 6 ½" SLAB OR LESS, PLACE ANCHORS SIDEWAYS AT 6" MIN. O.C. SLAB EDGE 2 STRANDS MIN. AT UNSUPPORTED SLAB EDGE, PARALLEL TO DISTRIBUTED TENDONS NOTE: TWO STRANDS TO PASS DIRECTLY OVER EACH COLUMN EACH WAY NOTES: 1. A STEEL PIPE IS REQUIRED TO BE INSERTED WHEN SLAB PENETRATION IS WITHIN 45° BEARING CONE OF TENDON ANCHOR. 2. PENETRATIONS FARTHER THAN 1.5 TIMES THE DIAMETER OF OPENING "D" OR 1.5 TIMES THE WIDTH OF THE OPENING "W", NOT LESS THAN 18", FROM ANCHOR DO NOT REQUIRE STEEL PIPE INSERTED. 3. PENETRATIONS WITH DIMENSIONS GREATER THAN 12" REQUIRE TRIM REBAR PER TYPICAL DETAILS. 4. SLEEVES SHALL NOT BE PLACED AFTER FINAL TENDON INSPECTIONS HAVE BEEN COMPLETED. 5. HORIZONTAL CONDUIT RUNS ARE NOT ALLOWED WITHIN THE HATCHED ANCHORAGE ZONE.45°18" MIN.1.5D OR 1.5WSLAB EDGE WIDTH "W"2 1/2" CLR.1' - 6"DIAMETER "D"24" MIN. L1 < L1 L28" MIN.EFFECTIVE LENGTH L1 < L1 L2 < L3 L3 NOTES: 1. INSERTS WHICH ARE CLOSER TO ONE ANOTHER THAN THE DIAMETER OF TEH LARGER OF THE TWO ARE CONSIDERED TO FORM A COMBINED OPENING. 2. IF THE COMBINED OPENING IS LESS THAN 12", NO TRIM BARS ARE REQUIRED. 3. IF THE COMBINED OPENING IS MORE THAN 12" BUT LESS THAN 24", PROVIDE (1)#5 TOP & BOTTOM WITH 1' - 6" EXTENSION PAST THE OPENING. 4. NO DIAGONAL BARS ARE NECESSARY. 5. IF THE COMBINED OPENING IS LARGER THAN 24", REFER TO TYPICAL SLAB OPENING FOR TRIM BARS. TRIM BARS NOTE: SINGLE OPENINGS OF SMALLER DIMENSIONA DO NOT REQUIRE TRIM BARS. TENDON (1)#5 TOP & BOTTOM TYP. 1' - 6" TYP. 3" CLR. TYP.1" CLR. TYP. 1 12 12" MIN.2" MIN.MAX. CURVATURE (TYP.) HAIRPIN, SEE TYPICAL DETAIL NOTES: 1. MILD REINFORCEMENT NOT SHOWN FOR CLARITY. REFER TO DETAIL X/SXXX FOR ADDITIONAL REINFORCING REQUIRED AT SLAB OPENINGS. 2. REFER TO PT TENDON DETAILS FOR REINFORCEMENT AS REQUIRED AT TENDON ANCHORAGES. COORDINATE WITH ADDITIONAL BURSTING STEEL REQUIREMENTS FROM PT SUPPLIER. 3. FOR ADDITIONAL INFORMATION AT TENDON SWEEP, REFER TO DETAIL X/SXXX. 4. DO NOT SLOPE TENDONS TIGHTER THAN 1:3 WITHOUT APPROVAL FROM EOR. INTERRUPTED TENDON, SEE PLAN NOTES: 1. LOCATE ANCHOR AT BULKHEAD PER PROJECT PLANS. 2. IF FABRICATED AT SHOP, WEDGES, GREASE CAP, AND SLEEVE WILL BE ASSEMBLED TIGHT TO ANCHOR 3. IF FIELD SEATING IS REQUIRED, VERIFY NO BARE STRAND IS EXPOSED. TAPE IF NECESSARY. ANCHOR STRAND (GREASED AND COATED) END CAP MONOWEDGES TYPE 1.5 PROTECTION SLEEVE SEE NOTE 1 BULKHEAD DEAD END ASSEMBLY NOTES: 1. LOCATE ANCHOR AT BULKHEAD PER PROJECT PLANS. 2. IF FABRICATED AT SHOP, WEDGES, GREASE CAP, AND SLEEVE WILL BE ASSEMBLED TIGHT TO ANCHOR 3. IF FIELD SEATING IS REQUIRED, VERIFY NO BARE STRAND IS EXPOSED. TAPE IF NECESSARY. 4. AFTER POURING, AT TIME OF STRESSING, REMOVE GROMMET AND INSERT WEDGES. 5. AFTER STRESSING, CUT STRAND TO WITHIN 1/8" OF END CAP AND GREASE END CAP PRIOR TO INSERTING IT TIGHT AGAINST ANCHOR. 6. PATCH STRESSING POCKET PER PROJECT PLANS. ANCHOR STRAND (GREASED AND COATED) END CAP MONOWEDGES TYPE 1.5 PROTECTION SLEEVE STRESSING END ASSEMBLY BULKHEAD GROMMET EQ.EQ.16" PT TENDON STRESSING TAIL GROMMET SUPPORT BARS AT 3'-0" O.C. MAX. ANCHOR CASTING#4 TOP AND BOTTOM BACKUP BARS TIED TO ANCHOR (LAP 2'-0" AS REQUIRED) NAIL TO FORMDISTRIBUTED TENDONS BANDED TENDONS EQ.EQ.16" PT TENDON STRESSING TAIL GROMMET SUPPORT BARS AT 48" O.C. MAX. ANCHOR CASTINGADDITIONAL (2)#4 TOP AND BOTTOM AT BANDED TENDON AT 12" O.C. EXTEND 1'-6" BEYOND LAST ANCHOR AT EACH END NAIL TO FORM #4 HAIRPIN IN BANDED DIRECTION ONLY. NUMBER OF HAIRPINS = NUMBER OF ANCHOR RODS PLUS (1). CENTER WITHIN SLAB THICKNESS 18" HAIRPIN THICKNESS TO BE 12" FOR 24" SLAB, 7" FOR 14" OR 18" SLAB, 4" FOR 9" SLAB EQ.EQ.16" PT TENDON STRESSING TAIL GROMMET SUPPORT BARS AT 3'-0" O.C. MAX. ANCHOR CASTING#4 TOP AND BOTTOM BACKUP BARS TIED TO ANCHOR (LAP 2'-0" AS REQUIRED) NAIL TO FORMDISTRIBUTED TENDONS BANDED TENDONS EQ.EQ.16" PT TENDON STRESSING TAIL GROMMET SUPPORT BARS AT 48" O.C. MAX. ANCHOR CASTINGADDITIONAL (2)#4 TOP AND BOTTOM AT BANDED TENDON AT 12" O.C. EXTEND 1'-6" BEYOND LAST ANCHOR AT EACH END NAIL TO FORM #4 HAIRPIN IN BANDED DIRECTION ONLY. NUMBER OF HAIRPINS = NUMBER OF ANCHOR RODS PLUS (1). CENTER WITHIN SLAB THICKNESS 18" HAIRPIN THICKNESS TO BE 12" FOR 24" SLAB, 7" FOR 14" OR 18" SLAB, 4" FOR 9" SLAB MIN. 2 1/2" CLEAR MIN. 2 1/2" CLEAR 2' - 6"3"2" MIN. CLEARBETWEEN TENDONSTENDON SWEEP NOTES: 1. WHERE TENDON SWEEP IS TIGHTER THAN 1:12, SEPARATE TENDONS BY 2" AT TURN AND ADD #3 OR #4 HAIRPINS AT 12" O.C. MAX. 2. HAIRPINS TO CAPTURE NO MORE THAN (4) TENDONS. PROVIDE ADDITIONAL HAIRPINS FOR LARGER TENDON GROUPINGS. 3. SEE P/T SHOP DRAWINGS FOR ADDITIONAL INFORMATION AND REQUIREMENTS. THE MORE STRINGENT HAIRPIN REQUIREMENTS BETWEEN THE SHOP DRAWINGS AND THIS DETAIL SHALL APPLY. 4. DO NOT SLOPE TENDONS TIGHTER THAN 1:3 WITHOUT ENGINEER APPROVAL. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:25 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS01.41 Author Checker DDS-025-22 TYPICAL ELEVATED SLAB DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"1 TYPICAL POST-TENSIONED SLAB TENDON DRAPE DETAILS 3/4" = 1'-0"2 TYPICAL MILD REINFORCEMENT IN P/T SLAB DETAIL 3/4" = 1'-0"3 P/T CONSTRUCTION JOINT (NON-TRANSFER SLABS) 3/4" = 1'-0"4 P/T CONSTRUCTION JOINT (TRANSFER SLABS) 3/4" = 1'-0"5 BANDED TENDONS AT MID-SPAN 3/4" = 1'-0"6 PROFILE FOR HARPED TENDONS AT SHEAR WALL / CANTILEVER 3/4" = 1'-0"7 SECTION THROUGH BANDED TENDON AT COLUMN 3/4" = 1'-0"8 FLARING OF BANDED TENDONS AT SLAB EDGE 3/4" = 1'-0"9 PLACEMENT OF ADDED TENDON 3/4" = 1'-0"10 TOP REINFORCEMENT AT EXTERIOR COLUMNS 3/4" = 1'-0"11 OPENINGS AT PT ANCHORAGE 3/4" = 1'-0"12 TRIM BARS FOR COMBINED OPENINGS 3/4" = 1'-0"13 TRIM BARS AT SLAB OPENINGS 10" - 24" 3/4" = 1'-0"14 TENDON PLACEMENT AT OPENING 24" OR LARGER 3/4" = 1'-0"15 ENCAPSULATED SYSTEM FOR TENDONS AT DEAD END 3/4" = 1'-0"16 ENCAPSULATED SYSTEM FOR TENDONS AT LIVE END 3/4" = 1'-0"17 END ANCHOR AT TENDONS - LIVE END 3/4" = 1'-0"18 END ANCHOR AT TENDONS - DEAD END 3/4" = 1'-0"19 TENDON SWEEP DETAIL DATE DESCRIPTION REV 3 AT 3", GROUP OF 4 ANCHORS MAX. 4" MIN. BETWEEN EACH GROUP OF ANCHORS #4x BETWEEN ANCHORS AS SHOWN 18" 18"SLAB THICKNESS PER PLANCONTINUOUS 9" TYP.LIMIT OF TENDON BAND CONTINUOUS 9" TYP. P/T ANCHOR, TYP. (2)#4 TOP AND BOTTOM. SEE TYPICAL END ANCHORAGE AT BANDED TENDON DETAIL FOR ADDITIONAL INFORMATION. PROTECT REBAR DURING CONSTRUCTION. CLEAN PRIOR TO PLACING CONCRETE. NOTES: 1. CLOSURE STRIP TO BE POURED WITH NON-SHRINK CONCRETE NOT LESS THAN 21 DAYS AFTER ADJACENT SLABS. 2. RETAIN SHORING UNTIL CLOSURE CONCRETE HAS REACHED 75% OF DESIGN STRENGTH OR 7 DAYS, MIN. 3. PROVIDE SHEAR KEY BETWEEN STRESSING HEADS FOR SLABS THICKER THAN 6" (SEE TYPICAL DETAILS), CLEAN JOINTS, AND APPLY BONDING AGENT PRIOR TO PLACING CONCRETE. 4. TO AVOID MISALIGNMENT BETWEEN ADJACENT SLABS, USE MECHANICAL METHODS SUCH AS JACKING IF NECESSARY. 5. USE ENCAPSULATED P.T. SYSTEM IF SLAB IS EXPOSED TO WEATHER OR CORROSIVE ENVIRONMENT AND CAULK TOP JOINTS ALL AROUND AS NOTED. 6. PROVIDE WATERPROOFING MEMBRANE IF REQUIRED FOR WATER-TIGHTNESS. 3"3" POUR STRIP 3'-6" U.N.O. ON PLAN COORDINATE WITH P.T. CONTRACTOR SEE NOTE 3 TOP REINFORCING AS SHOWN ON PLAN BOTTOM REINFORCING AS SHOWN ON PLAN ADDED TOP AND BOTTOM BARS AND HAIRPINS OR BACKUP BARS AS REQUIRED PER TYP. DETAILS (3)#6 BARS TOP AND BOTTOM CONTINUOUS PROVIDE 3/8" V-GROOVE AND SILICONE SEALANT TYP. AT TOP, AT PARKING DECK AND EXPOSED SLAB. NOTES: 1. EQUIPMENT, PIPING AND DUCTWORK SUSPENDED FROM OR PENETRATING THROUGH POST-TENSIONED SLAB SHALL BE CAPABLE OF ACCOMMODATING 1/2" OF DOWNWARD SLAB DEFLECTION DUE TO LIVE LOADS IMPOSED ON THE SLABS. 2. DESIGN OF ATTACHMENTS ABOVE BY INDIVIDUAL COMPONENT MANUFACTURER. 3. ATTACHMENT REQUIREMENTS APPLICABLE AT BOTH TOP AND BOTTOM OF SLAB. HILTI X-U UNIVERSAL FASTENER OR APPROVED EQUALPOWER DRIVEN FASTENERS3/4" MAX.3/8 HILTI HDI-P DROP-IN ANCHOR OR APPROVED EQUALDRILLED ANCHORS DO NOT OVER DRILL CAST-IN INSERTS SUBMIT TO SOR FOR APPROVALCAST-IN ANCHORS UNISTRUT EMBEDDED ANCHOR OR APPROVED EQUAL DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:25 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS01.42 Author Checker DDS-025-22 ELEVATED SLAB DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 3/4" = 1'-0"1 TYPICAL TENDON BAND REINFORCEMENT AT SLAB EDGE 3/4" = 1'-0"2 TYPICAL POUR STRIP 3/4" = 1'-0"3 ATTACHMENTS TO P/T SLAB STOP ALL HORIZ. JOINT REINF. AT CONTROL JOINT BUILDING PAPER OR OTHER BOND BREAK NOTES FOR MASONRY CONTROL JOINTS: 1. LOCATE AT CHANGES IN WALL HEIGHT OR WALL THICKNESS 2. ALIGN WITH MOVEMENT JOINTS IN FOUNDATIONS AND FLOORS 3. SPACE JOINTS AT THE LESSER OF 1.5x THE WALL HEIGHT OR EVERY 25 FEET 4. LOCATE ADJACENT TO WALL CORNERS OR WALL INTERSECTIONS WITHIN A DISTANCE EQUAL TO HALF THE CONTROL JOINT SPACING 5. LOCATE A MINIMUM OF TWO CELLS FROM ONE SIDE OF DOOR OR WINDOW OPENING LINTELS OPTION 1: PREFORMED GASKET OPTION 2: FORMED PAPER JOINT BACKER ROD AND SEALANT ON EACH FACE STOP ALL HORIZ. JOINT REINF. AT CONTROL JOINT PREFORMED GASKET IN CONCRETE MASONRY SASH UNIT BACKER ROD AND SEALANT ON EACH FACE GROUT VOID SOLID ELEVATED SLAB, SEE PLAN FOR THICKNESS AND REINF.2' - 8"8" CMU WALL. SEE DETAIL 4/S230 FOR CONNECTION AT TOP OF WALL #5 DOWELS TO MATCH VERTICAL BARS IN FULLY GROUTED CELLS W/ 1'-0" HOOK INTO SLAB SEE DETAIL 4/S230 FOR TOP OF CMU WALL CONNECTION PROVIDE CORNER BARS TO MATCH SIZE AND SPACING OF HORIZONTAL BOND BEAM REINFORCEMENT, PROVIDE 30" MINIMUM LAP SPLICE CORNER INTERSECTION T-INTERSECTION PLAN VIEW NOMINAL 8" DEEP CMU LINTEL WITH 1#5 HORIZONTAL AT ELEVATOR DOOR OPENING, MAXIMUM OPENING SPAN SHALL NOT EXCEED 4'-8"CONTINUOUS 1#5 JAMB REINFORCING EACH SIDE OF OPENING IN GROUT FILLED CELLS CMU WALL OPENING PROVIDE PREFABRICATED T- INTERSECTION HORIZONTAL JOINT REINFORCEMENT PROVIDE 3#5 VERTICAL CORNER BARS EACH CORNER OF SHAFT IN SOLID GROUT FILLED CELLS CORNER INTERSECTION T-INTERSECTION PLAN VIEW CMU WALL REINFORCED WITH #5 BARS SPACED AT 24" O.C. PROVIDE PREFABRICATED CORNER INTERSECTION HORIZONTAL JOINT REINFORCEMENT SOLID CMU AT TOP COURSE AT RATED WALL ASSEMBLY 3"x3"x1/4" x 8" ANGLE AT 4'-0" O.C. ATTACHED WITH (2) 3/8" EXPANSION OR SCREW ANCHORS WITH MIN. 4" EMBED, BOTH SIDES OF WALL MIN. 1", MAX. 2" BETWEEN SLAB AND TOP OF CMU SEE ARCH DRAWINGS FOR COMPRESSIBLE FILLER AND SEALANT REQUIREMENTS CMU WALL, SEE MASONRY NOTES AND DETAILS FOR ADDITIONAL INFORMATION SOLID CMU AT TOP COURSE AT RATED WALL ASSEMBLY 3"x3"x1/4" x 8" ANGLE AT 4'-0" O.C. ATTACHED WITH (2) 3/8" EXPANSION OR SCREW ANCHORS WITH MIN. 4" EMBED, BOTH SIDES OF WALL MIN. 1", MAX. 2" BETWEEN SLAB AND TOP OF CMU SEE ARCH DRAWINGS FOR COMPRESSIBLE FILLER AND SEALANT REQUIREMENTS CMU WALL, SEE MASONRY NOTES AND DETAILS FOR ADDITIONAL INFORMATION NOMINAL 8" DEEP CMU LINTEL WITH 1#5 HORIZONTAL AT ELEVATOR DOOR OPENING, MAXIMUM OPENING SPAN SHALL NOT EXCEED 4'-8" PROVIDE #5 VERTICAL BARS SPACED AT 24" O.C. MAX ALONG ALL SIDES OF SHAFT PROVIDE 3#5 VERTICAL CORNER BARS EACH CORNER OF SHAFT CORRIDOR UNIT UNITUNIT 10 S2.61 11 S2.61 10 S2.61 9 S2.61 8 S2.61 ELEVATOR SHAFT NOTE: PROVIDE NOMINAL 8" DEEP CMU BOND BEAM AT EACH FLOOR LEVEL REINFORCED WITH 2#5, SEE DETAILS FOR MORE INFORMATION. 2-HR RATED HORIZONTAL CEILING ASSEMBLY, SEE ARCH FOR SPECIFICATIONS AND REQUIREMENTS 2x10 JOISTS SPACED AT 16" O.C., SEE PLAN FOR ORIENTATION ELEVATOR HOIST BEAM, SEE PLAN FOR SIZE AND ORIENTATION 8" CMU BOND BEAM AT TOP OF CMU ELEVATOR SHAFT REINFORCED WITH 2#5 4"x6"x1/4" THICK BEARING PLATE WITH 1/2"Øx6" LONG HEADED STUDS FILL VOID WITH SOLID GROUT ONCE HOIST BEAM IS INSTALLED ELEVATOR SHAFT 4" P.T. (2) 2x8 PLATE WITH 1/2"Ø ANCHOR BOLTS SPACED AT 24" O.C. SIMPSON H2.5T EACH END OF JOIST AT PERPENDICULAR CONDITION DOUBLE JOIST AT EDGE OF SHAFT AT PARALLEL CONDITION AND 2x10 RIM JOIST AT PERPENDICULAR CONDITION TRUSSES PERPENDICULAR NOTES: 1. FOR LEDGER ATTACHMENT, PROVIDE MINIMUM 1½" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. 2. CORRDIOR LEDGER SCREWS SHALL BE DRIVEN INTO SOLID 4x4 VERTICALS OF LADDER TRUSS. 3. PROVIDE UP TO AN ADDITIONAL 1.5" OF LEVELING GYPCRETE IN FRONT OF ELEVATOR DOOR OPENING APPROXIMATELY 6 MONTHS AFTER BUILDING HAS BEEN 'CLOSED IN' TO ACCOUNT FOR ANY WOOD SHRINKAGE THAT HAS TAKEN PLACE. 8" DEEP CMU BOND BEAM AT EACH FLOOR LEVEL REINFORCED WITH 2#5 STAIR/ ELEVATOR SHAFT LADDER TRUSS WITH 4x4 VERTICALS SPACED AT 12" O.C.8" DEEP CMU LINTEL WITH 1#5 HORIZONTAL AT ELEVATOR DOOR OPENING, MAXIMUM OPENING SPAN SHALL NOT EXCEED 4'-8"COORD W/ELEV MANUFAT ELEVATOR: ELEVATOR SILL ANGLE AND CONNECTION BY ELEVATOR MANUFACTURER AT ELEVATOR: L6x4x5/16 LLV ALONG LENGTH OF ELEVATOR DOOR OPENING WITH 1/2"Øx6" LONG HEADED STUDS SPACED AT 12" O.C. 2x CEILING BELOW MECHANICAL PLENUM SEE SCHEDULE FOR CORRIDOR JOIST AND LEDGER SIZES AND FOR ATTACHMENTS CONTINUOUS 7/16" OSB NAILED TO TRUSS VERTICALS, TOP AND BOTTOM CHORD WITH 8d NAILS SPACED AT 4" O.C. ALONG ALL EDGES TRUSSES PERPENDICULAR 2x NAILER FOR CEILING ATTACHMENT CONTINUOUS 7/16" OSB NAILED TO TRUSS VERTICALS, TOP AND BOTTOM CHORD WITH 8d NAILS SPACED AT 4" O.C. ALONG ALL EDGES TOP CHORD BEARING CORRIDOR TRUSS 2x10 LEDGER WITH (2) ROWS OF SIMPSON SDWS22500DB SCREWS AT 12" O.C. LADDER TRUSS WITH 4x4 VERTICALS SPACED AT 12" O.C. NOTES: 1. FOR LEDGER ATTACHMENT, PROVIDE MINIMUM 1½" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. 2. CORRDIOR LEDGER SCREWS SHALL BE DRIVEN INTO SOLID 4x4 VERTICALS OF LADDER TRUSS. 8" DEEP CMU BOND BEAM AT EACH FLOOR LEVEL REINFORCED WITH 2#5 ELEVATOR SHAFT TRUSSES PERPENDICULAR 2x4 FLAT BLOCKING BETWEEN EACH TRUSS PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL 2x4 RIBBON 8" DEEP CMU BOND BEAM AT EACH FLOOR LEVEL REINFORCED WITH 2#5 ELEVATOR SHAFT LADDER TRUSS WITH VERTICALS SPACED TO MATCH SPACING OF WALL STUDS ABOVE TRUSSES PARALLEL 8" DEEP CMU BOND BEAM AT EACH FLOOR LEVEL REINFORCED WITH 2#5 ELEVATOR SHAFT DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:26 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS01.61 MG,GK,MS MJS DDS-025-22 MASONRY DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"5 CMU - TYPICAL WALL CONTROL JOINT 3/4" = 1'-0"12 MID-LEVEL SLAB AT CMU CRASH WALL 3/4" = 1'-0"1 TYPICAL BOND BEAM INTERSECTION 3/4" = 1'-0"2 TYPICAL CMU SHAFT OPENING 3/4" = 1'-0"3 TYPICAL WALL INTERSECTION REINFORCING 3/4" = 1'-0"4 CMU - TYPICAL TOP OF WALL AT CIP SLAB 1/2" = 1'-0"6 MASONRY ELEVATOR SHAFT - ENLARGED PLAN 3/4" = 1'-0"7 CMU ELEVATOR SHAFT - 2x ROOF FRAMING 3/4" = 1'-0"8 CMU SHAFT - CORRIDOR ENTRY 3/4" = 1'-0"9 CMU ELEVATOR SHAFT - CORRIDOR 3/4" = 1'-0"10 CMU ELEVATOR SHAFT - TRUSS BEARING 3/4" = 1'-0"11 CMU ELEVATOR SHAFT - NON BEARING DATE DESCRIPTION REV FOUNDATION PLAN LEGEND FOOTING LINE WALL CENTERLINE AND THICKENED SLAB FOOTING STEP DEPRESSED SLAB CONCRETE CURB OR OVERBUILT SLABF.S.SLAB ELEVATION CHANGE J K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T SWM VAULT SIZE, DEPTH, LOCATION TBD WILL IMPACT ADJACENT FOOTING SIZE, DEPTH, ORIENTATION FOUNDATION SCHEMATIC DESIGN ASSUMPTIONS • FOUNDATIONS WILL BE SUPPORTED UPON A COMBINATION OF WEATHERED ROCK, CONTROLLED FILL, OR GROUND IMPROVEMENT IN AREAS OF UNCONTROLLED FILLED THAT IS TOO DEEP FOR REMOVAL AND REPLACEMENT • FOUNDATIONS WILL BE DESIGNED FOR A NET ALLOWALBE SOIL BEARING PRESSURE OF 5000 PSF • BASEMENT WALLS UP AGAINST SOE WILL BE DESIGNED WITH AN ECCENTRIC FOOTING • INTERIOR FOOTINGS WILL BE PLACED AT 18" BELOW SLAB AND PERIMETER FOOTINGS WILL BE PLACED AT 12" BELOW SLAB UNLESS UTILITY ASPECTS OR STEPPING FOUNDATIONS DICTATE OTHERWISE • SWM VAULT IS NOT DETERMINED AT THIS TIME. FOOTINGS WILL COORDINATE WITH LAYOUT • SLAB ON GRADE TO BE 4" THICK AT INTERIOR RETAIL/AMENITY, AND 5" THICK WITH A COMBINATION OF W.W.M. AND MILD REINFORCEMENT ADJACENT TO STEPS IN THE FOUNDATION WALL • UNDERSLAB DRAINAGE SYSTEM WITHIN GRAVEL IS ANTICIPATED DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:27 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.01A Author Checker DDS-025-22 FOUNDATION PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCFOUNDATION PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 TYPICAL AREA SLAB ON GRADE 4" THICK REINFORCED WITH 6x6 W1.4xW1.4 W.W.M. PLACED IN UPPER THIRD OF SLAB SEE SHEET SXXX FOR ADDITIONAL INFORMATION 2 PARKING AREA SLAB ON GRADE 5" THICK REINFORCED WITH 6x6 W2.1xW2.1 W.W.M. PLACED IN UPPER THIRD OF SLAB SEE SHEET SXXX FOR ADDITIONAL INFORMATION 3 FINISHED FLOOR ELEVATION SEE PLAN FOR SLAB ELEVATIONS AND FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 4 WALL FOOTINGS INDICATED ON DRAWINGS AS WFX.X, SEE PLAN FOR TOP OF FOOTING ELEVATION SEE SCHEDULE AND DETAILS FOR SIZE AND REINFORCEMENT 5 ISOLATED COLUMN FOOTINGS INDICATED ON DRAWINGS AS FX.X, SEE PLAN FOR TOP OF FOOTING ELEVATION SEE SCHEDULES AND DETAILS FOR SIZE AND REINFORCEMENT 6 ISOLATED CONCRETE COLUMNS SEE CONCRETE COLUMN SCHEDULE FOR COLUMN SIZE AND REINFORCEMENT SEE SHEET SXXX FOR ADDITIONAL INFORMATION 7 UTILITIES LOWER FOOTINGS AS NEEDED TO PASS UTILITY LINES WITHIN 24" OF THE FOOTING THROUGH FOUNDATION WALLS, COORDINATE INVERT ELEVATIONS WITH CIVIL AND MEP DRAWINGS SEE X/SXXX AND X/SXXX FOR ADDTIONAL INFORMATION 8 FOOTING LOADS LOADS SHOWN ON PLAN REPRESENT TOTAL FACTORED ASD LOADS WALL FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH DEPTH CONTINUOUS REINFORCEMENT TRANSVERSE REINFORCEMENT ISOLATED FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH LENGTH DEPTH REINFORCEMENT REMARKS 12" MAT SLAB <varies> <varies> 1' - 0" F4.0 4' - 0" 4' - 0" 1' - 0" 14#8 EACH WAY F13.0 13' - 0" 13' - 0" 3' - 1" 14#8 EACH WAY DATE DESCRIPTION REV C D E F G H J 4 7 6 5 1 2 8 3 B OV XY SWM VAULT SIZE, DEPTH, LOCATION TBD WILL IMPACT ADJACENT FOOTING SIZE, DEPTH, ORIENTATION FOUNDATION PLAN LEGEND FOOTING LINE WALL CENTERLINE AND THICKENED SLAB FOOTING STEP DEPRESSED SLAB CONCRETE CURB OR OVERBUILT SLABF.S.SLAB ELEVATION CHANGE FOUNDATION SCHEMATIC DESIGN ASSUMPTIONS • FOUNDATIONS WILL BE SUPPORTED UPON A COMBINATION OF WEATHERED ROCK, CONTROLLED FILL, OR GROUND IMPROVEMENT IN AREAS OF UNCONTROLLED FILLED THAT IS TOO DEEP FOR REMOVAL AND REPLACEMENT • FOUNDATIONS WILL BE DESIGNED FOR A NET ALLOWALBE SOIL BEARING PRESSURE OF 5000 PSF • BASEMENT WALLS UP AGAINST SOE WILL BE DESIGNED WITH AN ECCENTRIC FOOTING • INTERIOR FOOTINGS WILL BE PLACED AT 18" BELOW SLAB AND PERIMETER FOOTINGS WILL BE PLACED AT 12" BELOW SLAB UNLESS UTILITY ASPECTS OR STEPPING FOUNDATIONS DICTATE OTHERWISE • SWM VAULT IS NOT DETERMINED AT THIS TIME. FOOTINGS WILL COORDINATE WITH LAYOUT • SLAB ON GRADE TO BE 4" THICK AT INTERIOR RETAIL/AMENITY, AND 5" THICK WITH A COMBINATION OF W.W.M. AND MILD REINFORCEMENT ADJACENT TO STEPS IN THE FOUNDATION WALL • UNDERSLAB DRAINAGE SYSTEM WITHIN GRAVEL IS ANTICIPATED DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:28 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.01B Author Checker DDS-025-22 FOUNDATION PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 FOUNDATION PLAN - PART B FOUNDATION PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 TYPICAL AREA SLAB ON GRADE 4" THICK REINFORCED WITH 6x6 W1.4xW1.4 W.W.M. PLACED IN UPPER THIRD OF SLAB SEE SHEET SXXX FOR ADDITIONAL INFORMATION 2 PARKING AREA SLAB ON GRADE 5" THICK REINFORCED WITH 6x6 W2.1xW2.1 W.W.M. PLACED IN UPPER THIRD OF SLAB SEE SHEET SXXX FOR ADDITIONAL INFORMATION 3 FINISHED FLOOR ELEVATION SEE PLAN FOR SLAB ELEVATIONS AND FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 4 WALL FOOTINGS INDICATED ON DRAWINGS AS WFX.X, SEE PLAN FOR TOP OF FOOTING ELEVATION SEE SCHEDULE AND DETAILS FOR SIZE AND REINFORCEMENT 5 ISOLATED COLUMN FOOTINGS INDICATED ON DRAWINGS AS FX.X, SEE PLAN FOR TOP OF FOOTING ELEVATION SEE SCHEDULES AND DETAILS FOR SIZE AND REINFORCEMENT 6 ISOLATED CONCRETE COLUMNS SEE CONCRETE COLUMN SCHEDULE FOR COLUMN SIZE AND REINFORCEMENT SEE SHEET SXXX FOR ADDITIONAL INFORMATION 7 UTILITIES LOWER FOOTINGS AS NEEDED TO PASS UTILITY LINES WITHIN 24" OF THE FOOTING THROUGH FOUNDATION WALLS, COORDINATE INVERT ELEVATIONS WITH CIVIL AND MEP DRAWINGS SEE X/SXXX AND X/SXXX FOR ADDTIONAL INFORMATION 8 FOOTING LOADS LOADS SHOWN ON PLAN REPRESENT TOTAL FACTORED ASD LOADS WALL FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH DEPTH CONTINUOUS REINFORCEMENT TRANSVERSE REINFORCEMENT ISOLATED FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH LENGTH DEPTH REINFORCEMENT REMARKS 12" MAT SLAB <varies> <varies> 1' - 0" F4.0 4' - 0" 4' - 0" 1' - 0" 14#8 EACH WAY F13.0 13' - 0" 13' - 0" 3' - 1" 14#8 EACH WAY 9 10 11 13 14 16 17 8 OV XY 15 12 FOUNDATION PLAN LEGEND FOOTING LINE WALL CENTERLINE AND THICKENED SLAB FOOTING STEP DEPRESSED SLAB CONCRETE CURB OR OVERBUILT SLABF.S.SLAB ELEVATION CHANGE FOUNDATION SCHEMATIC DESIGN ASSUMPTIONS • FOUNDATIONS WILL BE SUPPORTED UPON A COMBINATION OF WEATHERED ROCK, CONTROLLED FILL, OR GROUND IMPROVEMENT IN AREAS OF UNCONTROLLED FILLED THAT IS TOO DEEP FOR REMOVAL AND REPLACEMENT • FOUNDATIONS WILL BE DESIGNED FOR A NET ALLOWALBE SOIL BEARING PRESSURE OF 5000 PSF • BASEMENT WALLS UP AGAINST SOE WILL BE DESIGNED WITH AN ECCENTRIC FOOTING • INTERIOR FOOTINGS WILL BE PLACED AT 18" BELOW SLAB AND PERIMETER FOOTINGS WILL BE PLACED AT 12" BELOW SLAB UNLESS UTILITY ASPECTS OR STEPPING FOUNDATIONS DICTATE OTHERWISE • SWM VAULT IS NOT DETERMINED AT THIS TIME. FOOTINGS WILL COORDINATE WITH LAYOUT • SLAB ON GRADE TO BE 4" THICK AT INTERIOR RETAIL/AMENITY, AND 5" THICK WITH A COMBINATION OF W.W.M. AND MILD REINFORCEMENT ADJACENT TO STEPS IN THE FOUNDATION WALL • UNDERSLAB DRAINAGE SYSTEM WITHIN GRAVEL IS ANTICIPATED DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:30 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.01C Author Checker DDS-025-22 FOUNDATION PLAN -PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 FOUNDATION PLAN - PART C FOUNDATION PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 TYPICAL AREA SLAB ON GRADE 4" THICK REINFORCED WITH 6x6 W1.4xW1.4 W.W.M. PLACED IN UPPER THIRD OF SLAB SEE SHEET SXXX FOR ADDITIONAL INFORMATION 2 PARKING AREA SLAB ON GRADE 5" THICK REINFORCED WITH 6x6 W2.1xW2.1 W.W.M. PLACED IN UPPER THIRD OF SLAB SEE SHEET SXXX FOR ADDITIONAL INFORMATION 3 FINISHED FLOOR ELEVATION SEE PLAN FOR SLAB ELEVATIONS AND FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 4 WALL FOOTINGS INDICATED ON DRAWINGS AS WFX.X, SEE PLAN FOR TOP OF FOOTING ELEVATION SEE SCHEDULE AND DETAILS FOR SIZE AND REINFORCEMENT 5 ISOLATED COLUMN FOOTINGS INDICATED ON DRAWINGS AS FX.X, SEE PLAN FOR TOP OF FOOTING ELEVATION SEE SCHEDULES AND DETAILS FOR SIZE AND REINFORCEMENT 6 ISOLATED CONCRETE COLUMNS SEE CONCRETE COLUMN SCHEDULE FOR COLUMN SIZE AND REINFORCEMENT SEE SHEET SXXX FOR ADDITIONAL INFORMATION 7 UTILITIES LOWER FOOTINGS AS NEEDED TO PASS UTILITY LINES WITHIN 24" OF THE FOOTING THROUGH FOUNDATION WALLS, COORDINATE INVERT ELEVATIONS WITH CIVIL AND MEP DRAWINGS SEE X/SXXX AND X/SXXX FOR ADDTIONAL INFORMATION 8 FOOTING LOADS LOADS SHOWN ON PLAN REPRESENT TOTAL FACTORED ASD LOADS WALL FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH DEPTH CONTINUOUS REINFORCEMENT TRANSVERSE REINFORCEMENT ISOLATED FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH LENGTH DEPTH REINFORCEMENT REMARKS 12" MAT SLAB <varies> <varies> 1' - 0" F4.0 4' - 0" 4' - 0" 1' - 0" 14#8 EACH WAY F13.0 13' - 0" 13' - 0" 3' - 1" 14#8 EACH WAY J K L M N P Q R 4 U 7 6 5 1 2 S 8 3 TJKLMNPQR 4 U 7 6 5 1 2 S 8 3 T FOUNDATION SCHEMATIC DESIGN ASSUMPTIONS • FOUNDATIONS WILL BE SUPPORTED UPON A COMBINATION OF WEATHERED ROCK, CONTROLLED FILL, OR GROUND IMPROVEMENT IN AREAS OF UNCONTROLLED FILLED THAT IS TOO DEEP FOR REMOVAL AND REPLACEMENT • FOUNDATIONS WILL BE DESIGNED FOR A NET ALLOWALBE SOIL BEARING PRESSURE OF 5000 PSF • BASEMENT WALLS UP AGAINST SOE WILL BE DESIGNED WITH AN ECCENTRIC FOOTING • INTERIOR FOOTINGS WILL BE PLACED AT 18" BELOW SLAB AND PERIMETER FOOTINGS WILL BE PLACED AT 12" BELOW SLAB UNLESS UTILITY ASPECTS OR STEPPING FOUNDATIONS DICTATE OTHERWISE • SWM VAULT IS NOT DETERMINED AT THIS TIME. FOOTINGS WILL COORDINATE WITH LAYOUT • SLAB ON GRADE TO BE 4" THICK AT INTERIOR RETAIL/AMENITY, AND 5" THICK WITH A COMBINATION OF W.W.M. AND MILD REINFORCEMENT ADJACENT TO STEPS IN THE FOUNDATION WALL • UNDERSLAB DRAINAGE SYSTEM WITHIN GRAVEL IS ANTICIPATED DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:31 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.02A Author Checker DDS-025-22 LEVEL 2 ELEVATED SLAB PLAN - PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 2 - PART A WALL FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH DEPTH CONTINUOUS REINFORCEMENT TRANSVERSE REINFORCEMENT ISOLATED FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH LENGTH DEPTH REINFORCEMENT REMARKS 12" MAT SLAB <varies> <varies> 1' - 0" F4.0 4' - 0" 4' - 0" 1' - 0" 14#8 EACH WAY F13.0 13' - 0" 13' - 0" 3' - 1" 14#8 EACH WAY ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION SCHEMATIC DESIGN NOTES: • FOOTINGS ADJACENT TO BUILDING STEP WILL BE LOWERED. C D E F G H J 4 7 6 5 1 2 8 3 B OV XY C D E F G H J 4 7 6 5 1 2 8 3 B OV XY FOUNDATION SCHEMATIC DESIGN ASSUMPTIONS • FOUNDATIONS WILL BE SUPPORTED UPON A COMBINATION OF WEATHERED ROCK, CONTROLLED FILL, OR GROUND IMPROVEMENT IN AREAS OF UNCONTROLLED FILLED THAT IS TOO DEEP FOR REMOVAL AND REPLACEMENT • FOUNDATIONS WILL BE DESIGNED FOR A NET ALLOWALBE SOIL BEARING PRESSURE OF 5000 PSF • BASEMENT WALLS UP AGAINST SOE WILL BE DESIGNED WITH AN ECCENTRIC FOOTING • INTERIOR FOOTINGS WILL BE PLACED AT 18" BELOW SLAB AND PERIMETER FOOTINGS WILL BE PLACED AT 12" BELOW SLAB UNLESS UTILITY ASPECTS OR STEPPING FOUNDATIONS DICTATE OTHERWISE • SWM VAULT IS NOT DETERMINED AT THIS TIME. FOOTINGS WILL COORDINATE WITH LAYOUT • SLAB ON GRADE TO BE 4" THICK AT INTERIOR RETAIL/AMENITY, AND 5" THICK WITH A COMBINATION OF W.W.M. AND MILD REINFORCEMENT ADJACENT TO STEPS IN THE FOUNDATION WALL • UNDERSLAB DRAINAGE SYSTEM WITHIN GRAVEL IS ANTICIPATED DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:32 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.02B Author Checker DDS-025-22 LEVEL 2 SLAB/FOUNDATION PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 2 SLAB/FOUNDATION PLAN - PART B FOUNDATION PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 TYPICAL AREA SLAB ON GRADE 4" THICK REINFORCED WITH 6x6 W1.4xW1.4 W.W.M. PLACED IN UPPER THIRD OF SLAB SEE SHEET SXXX FOR ADDITIONAL INFORMATION 2 PARKING AREA SLAB ON GRADE 5" THICK REINFORCED WITH 6x6 W2.1xW2.1 W.W.M. PLACED IN UPPER THIRD OF SLAB SEE SHEET SXXX FOR ADDITIONAL INFORMATION 3 FINISHED FLOOR ELEVATION SEE PLAN FOR SLAB ELEVATIONS AND FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 4 WALL FOOTINGS INDICATED ON DRAWINGS AS WFX.X, SEE PLAN FOR TOP OF FOOTING ELEVATION SEE SCHEDULE AND DETAILS FOR SIZE AND REINFORCEMENT 5 ISOLATED COLUMN FOOTINGS INDICATED ON DRAWINGS AS FX.X, SEE PLAN FOR TOP OF FOOTING ELEVATION SEE SCHEDULES AND DETAILS FOR SIZE AND REINFORCEMENT 6 ISOLATED CONCRETE COLUMNS SEE CONCRETE COLUMN SCHEDULE FOR COLUMN SIZE AND REINFORCEMENT SEE SHEET SXXX FOR ADDITIONAL INFORMATION 7 UTILITIES LOWER FOOTINGS AS NEEDED TO PASS UTILITY LINES WITHIN 24" OF THE FOOTING THROUGH FOUNDATION WALLS, COORDINATE INVERT ELEVATIONS WITH CIVIL AND MEP DRAWINGS SEE X/SXXX AND X/SXXX FOR ADDTIONAL INFORMATION 8 FOOTING LOADS LOADS SHOWN ON PLAN REPRESENT TOTAL FACTORED ASD LOADS WALL FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH DEPTH CONTINUOUS REINFORCEMENT TRANSVERSE REINFORCEMENT ISOLATED FOOTING SCHEDULE (5000 PSF ALLOWABLE BEARING) MARK WIDTH LENGTH DEPTH REINFORCEMENT REMARKS 12" MAT SLAB <varies> <varies> 1' - 0" F4.0 4' - 0" 4' - 0" 1' - 0" 14#8 EACH WAY F13.0 13' - 0" 13' - 0" 3' - 1" 14#8 EACH WAY SCHEMATIC DESIGN NOTES: • FOOTINGS ADJACENT TO BUILDING STEP WILL BE LOWERED. 9 10 11 13 14 16 17 8 OV XY 15 12 9 10 11 13 14 16 17 8 OV XY 15 12 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:33 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.02C Author Checker DDS-025-22 LEVEL 2 ELEVATED SLAB PLAN - PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV J K L M N P Q R 4 U 7 6 5 1 2 S 8 3 TJKLMNPQR 4 U 7 6 5 1 2 S 8 3 T MID-LEVEL ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 9" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • ANTICIPATE POUR STRIP AGAINST HIGH GRADE FOUNDATION WALL AND AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:35 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.03A Author Checker DDS-025-22 LEVEL 3 ELEVATED SLAB PLAN - PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION SLAB REINFORCEMENT AND PLACEMENT LEGEND TOP BARS N#XxL@S N = NUMBER OF BARS X = SIZE OF BARS L = LENGTH OF BARS (IN FEET) S = SPACING OF BARS (IN INCHES) ADDITIONAL BOTTOM BARS N#XxL@SB N = NUMBER OF BARS X = SIZE OF BARS L = LENGTH OF BARS (IN FEET) S = SPACING OF BARS (IN INCHES) B = ADDITIONAL BOTTOM BARS REBAR PLACEMENT INNERMOST LAYER 'PLAN' EAST-WEST DIRECTION OUTERMOST LAYER'PLAN' NORTH-SOUTH DIRECTIONCONDUIT PLACEMENT WITHIN ELEVATED SLABS • CONDUIT IS TO BE SPACED AT 3x THE CONDUIT DIAMETER • CONDUIT SIZE SHALL NOT EXCEED 3" IN DIAMETER • HORIZONTAL CONDUIT SHALL NOT BE PLACED WITHIN 3 FEET OF CONCRETE COLUMNS OR 1 FOOT FROM CONCRETE COLUMN STUD RAILS • CONDUIT SHALL NOT CROSS EACH OTHER • CONDUIT SHALL NOT DISPLACE REBAR • CONDUIT SHALL NOT BE ALUMINUM • A MAXIMUM OF (3) CONDUITS ARE PERMITTED WITHIN A 5'-0" WIDE SECTION OF ELEVATED SLAB • CONTRACTOR TO SUBMIT CONDUIT LAYOUT PLAN TO SER PRIOR TO CONCRETE PLACEMENT FOR APPROVAL J K L M N P Q R 4 U 7 6 5 1 2 S 8 3 TJKLMNPQR 4 U 7 6 5 1 2 S 8 3 T DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:35 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.03AR Author Checker DDS-025-22 LEVEL 3 ELEVATED SLAB REINF. PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV ELEVATED TRANSFER SLAB PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB TYPICAL XX" THICK WITH #X AT XX" O.C. BOTTOM MAT U.N.O. ON PLAN TOP BARS AND ADDITIONAL BOTTOM BARS INDICATED ON PLAN 2 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 3 TOP OF SLAB ELEVATION SEE PLAN FOR SLAB ELEVATIONS AND FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 1/8" = 1'-0"1 LEVEL 3 ELEVATED SLAB REINF. PLAN - PART A C D E F G H J 4 7 6 5 1 2 8 3 B OV XY C D E F G H J 4 7 6 5 1 2 8 3 B OV XY MID-LEVEL ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 9" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • ANTICIPATE POUR STRIP AGAINST HIGH GRADE FOUNDATION WALL AND AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:37 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.03B Author Checker DDS-025-22 LEVEL 3 ELEVATED SLAB PLAN - PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 3 ELEVATED SLAB PLAN - PART B ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION C D E F G H J 4 7 6 5 1 2 8 3 B OV XY C D E F G H J 4 7 6 5 1 2 8 3 B OV XY DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:37 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.03BR Author Checker DDS-025-22 LEVEL 3 ELEVATED SLAB REINF. PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 3 ELEVATED SLAB REINF. PLAN - PART B 9 10 11 13 14 16 17 8 OV XY 15 12 9 10 11 13 14 16 17 8 OV XY 15 12 MID-LEVEL ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 9" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • ANTICIPATE POUR STRIP AGAINST HIGH GRADE FOUNDATION WALL AND AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:39 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.03C Author Checker DDS-025-22 LEVEL 3 ELEVATED SLAB PLAN - PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 3 ELEVATED SLAB PLAN - PART C ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION 9 10 11 13 14 16 17 8 OV XY 15 12 9 10 11 13 14 16 17 8 OV XY 15 12 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:39 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.03CR Author Checker DDS-025-22 LEVEL 3 ELEVATED SLAB REINF. PLAN -PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 3 ELEVATED SLAB REINF. PLAN - PART C J K L M N P Q R 4 U 7 6 5 1 2 S 8 3 TJKLMNPQR 4 U 7 6 5 1 2 S 8 3 T MID-LEVEL ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 9" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • ANTICIPATE POUR STRIP AGAINST HIGH GRADE FOUNDATION WALL AND AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:41 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.04A Author Checker DDS-025-22 LEVEL 4 ELEVATED SLAB PLAN - PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 4 ELEVATED SLAB PLAN - PART A ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION J K L M N P Q R 4 U 7 6 5 1 2 S 8 3 TJKLMNPQR 4 U 7 6 5 1 2 S 8 3 T DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:41 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.04AR Author Checker DDS-025-22 LEVEL 4 ELEVATED SLAB REINF. PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 4 ELEVATED SLAB REINF. PLAN - PART A C D E F G H J 4 7 6 5 1 2 8 3 B OV XY C D E F G H J 4 7 6 5 1 2 8 3 B OV XY MID-LEVEL ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 9" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • ANTICIPATE POUR STRIP AGAINST HIGH GRADE FOUNDATION WALL AND AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:43 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.04B Author Checker DDS-025-22 LEVEL 4 ELEVATED SLAB PLAN - PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 4 ELEVATED SLAB PLAN - PART B ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION C D E F G H J 4 7 6 5 1 2 8 3 B OV XY C D E F G H J 4 7 6 5 1 2 8 3 B OV XY DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:43 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.04BR Author Checker DDS-025-22 LEVEL 4 ELEVATED SLAB REINF. PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 4 ELEVATED SLAB REINF. PLAN - PART B 9 10 11 13 14 16 17 8 OV XY 15 12 9 10 11 13 14 16 17 8 OV XY 15 12 TRANSFER ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 16" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • 8" TO 12" STEP DOWN INTO COURTYARDS • ANTICIPATE BEAMS AND SUPPORTING COLUMNS AROUND RECESSED POOL • ANTICIPATE POUR STRIP AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS (8" CMU ABOVE) DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:45 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.04C Author Checker DDS-025-22 LEVEL 4 ELEVATED SLAB PLAN - PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 4 ELEVATED SLAB PLAN - PART C ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION 9 10 11 13 14 16 17 8 OV XY 15 12 9 10 11 13 14 16 17 8 OV XY 15 12 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:46 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.04CR Author Checker DDS-025-22 LEVEL 4 ELEVATED SLAB REINF. PLAN -PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 4 ELEVATED SLAB REINF. PLAN - PART C J K L M N P Q R 4 U 7 6 5 1 2 S 8 3 TJKLMNPQR 4 U 7 6 5 1 2 S 8 3 T MID-LEVEL ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 9" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • ANTICIPATE POUR STRIP AGAINST HIGH GRADE FOUNDATION WALL AND AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:47 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.05A Author Checker DDS-025-22 LEVEL 5 ELEVATED SLAB PLAN - PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 5 ELEVATED SLAB PLAN - PART A ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION J K L M N P Q R 4 U 7 6 5 1 2 S 8 3 TJKLMNPQR 4 U 7 6 5 1 2 S 8 3 T DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:48 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.05AR Author Checker DDS-025-22 LEVEL 5 ELEVATED SLAB REINF. PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 5 ELEVATED SLAB REINF. PLAN - PART A C D E F G H J 4 7 6 5 1 2 8 3 B OV XY C D E F G H J 4 7 6 5 1 2 8 3 B OV XY MID-LEVEL ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 9" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • ANTICIPATE POUR STRIP AGAINST HIGH GRADE FOUNDATION WALL AND AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:49 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.05B Author Checker DDS-025-22 LEVEL 5 ELEVATED SLAB PLAN - PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 5 ELEVATED SLAB PLAN - PART B ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION C D E F G H J 4 7 6 5 1 2 8 3 B OV XY C D E F G H J 4 7 6 5 1 2 8 3 B OV XY DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:50 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.05BR Author Checker DDS-025-22 LEVEL 5 ELEVATED SLAB REINF. PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 5 ELEVATED SLAB REINF. PLAN - PART B NOTE: LOCATE COURTYARD DRAINS PER LANDSCAPE AND PLUMBING DRAWINGS8"8" 8"8"TRANSFER ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 16" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • 8" TO 12" STEP DOWN INTO COURTYARDS • ANTICIPATE BEAMS AND SUPPORTING COLUMNS AROUND RECESSED POOL • ANTICIPATE POUR STRIP AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS (8" CMU ABOVE) DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:51 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.06A Author Checker DDS-025-22 LEVEL 6 ELEVATED SLAB PLAN - PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 6 ELEVATED SLAB PLAN - PART A ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:52 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.06AR Author Checker DDS-025-22 LEVEL 6 ELEVATED SLAB REINF. PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 6 ELEVATED SLAB REINF. PLAN - PART A 8" 8"8"8"8"TRANSFER ELEVATED SLAB SCHEMATIC DESIGN ASSUMPTIONS • ESTIMATED 16" THICK POST TENSIONED SLAB • 18"x24" SUPPORTING CONCRETE COLUMNS • MAJORITY OF COLUMNS WILL REQUIRE STUDRAILS FOR INCREASED SHEAR CAPACITY • ADDITIONAL MILD BARS TO BE PLACED OVER COLUMN LOCATIONS • 8" TO 12" STEP DOWN INTO COURTYARDS • ANTICIPATE BEAMS AND SUPPORTING COLUMNS AROUND RECESSED POOL • ANTICIPATE POUR STRIP AROUND MID-SLAB IN THE EAST-WEST DIRECTION • STAIRWELL AND ELEVATOR WALLS SUPPORTING SLABS TO BE 10" CONCRETE WALLS (8" CMU ABOVE) DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:53 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.06B Author Checker DDS-025-22 LEVEL 6 ELEVATED SLAB PLAN - PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 6 ELEVATED SLAB PLAN - PART B ELEVATED POST TENSIONED SLAB LAYOUT NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ELEVATED SLAB REFER TO PLAN FOR TOP AND BOTTOM OF SLAB ELEVATIONS ELEVATIONS LISTED ABOVE AND BELOW SLAB ELEVATION MARK RESPECTIVELY 2 TOP OF SLAB CONFIGURATIO N SEE PLAN FOR LOCATIONS OF SLOPED SLABS, STEPS IN SLAB, DRAINS, AND DEPRESSIONS VERIFY WITH LATEST ARCHITECTURAL AND CIVIL DRAWINGS 3 SLAB OPENINGS PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENINGS SEE DETAIL X/SXXX FOR ADDITIONAL INFORMATION 4 POUR STRIPS HATCHED AREA ON PLAN INDICATES POUR STRIP TO REMAIN OPEN FOR A MINIMUM OF 28 DAYS AFTER COMPLETION OF SLAB STRESSING REFER TO X/SXXX FOR ADDITIONAL INFORMATION 5 REFERENCE INFORMATION REFER TO SHEETS S01.41 AND S01.42 FOR TYPICAL DETAILS TO BE INCORPORATED AT ALL APPLICABLE LOCATIONS BY SUPPLIER AND/OR CONTRACTOR DETAILS MAY OR MAY NOT BE IDENTIFIED ON PLANS 6 SLAB CORING POST TENSIONED SLAB SHALL NOT BE CORED UNLESS APPROVED BY SER. CORE LOCATIONS SHALL BE SCANNED LOCATE TENDONS, STUDRAILS, AND MILD BARS. SEE DETAILS X/SXXX FOR ADDITIONAL CORE DRILLING LIMITATIONS 7 DAMAGED TENDONS TENDONS DAMAGED DURING PLACEMENT OR CONSTRUCTION SHALL BE REPAIRED BY SUPPLIER AND/OR CONTRACTOR. PROPOSED REPAIR SOLUTIONS SHOULD BE SUBMITTED TO THE SER PRIOR TO IMPLEMENTATION DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:09:54 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS02.06BR Author Checker DDS-025-22 LEVEL 6 ELEVATED SLAB REINF. PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 6 ELEVATED SLAB REINF. PLAN - PART B XXX G.T. FRAMING PLAN LEGEND TRUSS SPAN DIRECTION INTERIOR BEARING WALL DROPPED HEADER WOOD BEARING WALL TAG4A FLUSH BEAM GIRDER TRUSS JOIST/RAFTER/TRUSS ADDITIONAL LOADING FLOOR HEADER SCHEDULE LOCATION MAXIMUM CLEAR SPAN SIZE EXTERIOR WALL X'-X" TO X'-X" (X) 2xX EXTERIOR WALL CORRIDOR WALL INTERIOR BEARING WALL (X) 2xX (X) 2xX (X) 2xX X'-X" TO X'-X" X'-X" TO X'-X" X'-X" TO X'-X" 1. ALL EXTERIOR WALL OPENINGS SHALL HAVE A MINIMUM (2) JACK STUDS AND (2) KING STUDS. 2. ALL INTERIOR WALL OPENINGS SHALL HAVE A MINIMUM (2) JACK STUDS AND (1) KING STUD. WOOD BEARING WALL STUD SCHEDULE 5TH FLR. TO ROOF MARKLEVEL 2x4@XX 4A 4B 4C 6A 6B 2x4@XX 2x4@XX 2x6@XX 2x6@XX 4TH FLR. TO 5TH FLR. 2x4@XX 2x4@XX 2x4@XX 2x6@XX 2x6@XX 3RD FLR. TO 4TH FLR. 2x4@XX 2x4@XX 2x4@XX 2x6@XX 2x6@XX 2ND FLR. TO 3RD FLR. 2x4@XX 2x4@XX 2x4@XX 2x6@XX 2x6@XX 1ST FLR. TO 2ND FLR. 2x4@XX 2x4@XX 2x4@XX 2x6@XX 2x6@XX 1. ALL UNIT SEPARATION WALLS TO BE TYPE "4A", ALL INTERIOR BEARING WALLS TO BE TYPE "4B" AND ALL EXTERIOR WALLS TO BE TYPE "6A" UNLESS NOTED OTHERWISE ON PLAN. 2. ALL WET WALLS DESIGNATED AS BEARING WALLS SHALL BE 2x6 MINIMUM AND SPACED TO MATCH THE 2x4 WALL INDICATION. 3. (D) - INDICATES DOUBLE STUDS AT TRUSS BEARING LOCATIONS. 4. (T) - INDICATES TRIPLE STUDS AT TRUSS BEARING LOCATIONS. 5. STUDS SHALL ALIGN WITH TRUSSES WHEN BOTH ARE SPACED AT 16" O.C. AND WHEN TRUSSES ARE SPACED AT 12" OR 24" AND STUDS ARE SPACED AT 12" O.C. 6. PROVIDE MID-HEIGHT BLOCKING BETWEEN EVERY STUD WHERE STUD HEIGHT EXCEEDS 9'-4". 7. NON-BEARING WALLS MAY HAVE STUDS SPACED AT 24" O.C. MAXIMUM ASSUMING A TIGHTER STUD SPACING IS NOT REQUIRED BY THE OWNER, ARCHITECT, OR GENERAL CONTRACTOR. WOOD COLUMN SCHEDULE 5TH FLR. TO ROOF MARKLEVEL C1 4TH FLR. TO 5TH FLR. 3RD FLR. TO 4TH FLR. 2ND FLR. TO 3RD FLR. 1ST FLR. TO 2ND FLR. (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX C2 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX C3 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX C4 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX C5 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX WOOD CORRIDOR JOIST AND LEDGER SCHEDULE JOIST SIZE AND SPACING 1. LEDGER SHALL BE SINGLE 2x TO MATCH JOIST DEPTH. 2. FOR LEDGER ATTACHMENT, PROVIDE MINIMUM 1½" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. 3. LEDGER SCREWS SHALL BE DRIVEN INTO SOLID 4x4 VERTICALS OF LADDER TRUSSES WHEN FLOOR FRAMING IS PARALLEL TO CORRIDOR WALL. 4. LEDGER SCREWS SHALL BE DRIVEN INTO WIDE FACE OF (2)2x4 CRIPPLE BLOCKING OR TRUSS END VERTICALS WHEN FLOOR FRAMING IS PERPENDICULAR TO CORRIDOR WALL. 5. LOAD FROM SPRINKLER PIPES SHALL NOT EXCEED 250 LBS ON ANY JOIST. MAXIMUM SPRINKLER PIPE HANGER SPACING FOR SCHEDULE 40 PIPE SHALL NOT EXCEED 5'-4" FOR 8"Ø AND 8'-0" FOR 6"Ø. 2x10 AT 16" O.C. (2) 2x10 AT 16" O.C. 12'-6" 8'-0" MAXIMUM SPAN JOIST HANGER LUS28 LUS28-2 LEDGER ATTACHMENT (2) ROWS OF SIMPSON SDWS- 22500DB SCREWS AT 12" O.C. WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:02 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.05C Author Checker DDS-025-22 LEVEL 5 FLOOR FRAMING PLAN -PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCFLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB DATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 5 FLOOR FRAMING PLAN - PART C WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:04 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.06C Author Checker DDS-025-22 LEVEL 6 FLOOR FRAMING PLAN -PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 6 FLOOR FRAMING PLAN - PART C FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:07 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.07A Author Checker DDS-025-22 LEVEL 7 FLOOR FRAMING PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 7 FLOOR FRAMING PLAN - PART A FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:09 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.07B Author Checker DDS-025-22 LEVEL 7 FLOOR FRAMING PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 7 FLOOR FRAMING PLAN - PART B FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:11 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.07C Author Checker DDS-025-22 LEVEL 7 FLOOR FRAMING PLAN -PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 7 FLOOR FRAMING PLAN - PART C FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:14 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.08A Author Checker DDS-025-22 LEVEL 8 FLOOR FRAMING PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 8 FLOOR FRAMING PLAN - PART A FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:16 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.08B Author Checker DDS-025-22 LEVEL 8 FLOOR FRAMING PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 8 FLOOR FRAMING PLAN - PART B FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:17 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.08C Author Checker DDS-025-22 LEVEL 8 FLOOR FRAMING PLAN -PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 8 FLOOR FRAMING PLAN - PART C FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:20 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.09A Author Checker DDS-025-22 LEVEL 9 FLOOR FRAMING PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 9 FLOOR FRAMING PLAN - PART A FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:22 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.09B Author Checker DDS-025-22 LEVEL 9 FLOOR FRAMING PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 9 FLOOR FRAMING PLAN - PART B FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED ROOF SCHEMATIC DESIGN ASSUMPTIONS • ROOF TRUSSES TYPICALLY SPANNING FROM CORRIDOR TO EXTERIOR W/ 1/4" PER FOOT TOP CHORD SLOPE. 30" MINIMUM DEPTH • 'FLAT' ROOF SHEATHED WITH 23/32" APA RATED SHEATHING DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:24 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.09C Author Checker DDS-025-22 LEVEL 9 LOW ROOF FRAMING PLAN -PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 9 LOW ROOF FRAMING PLAN - PART C ROOF FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ROOF TRUSSES PRE-FABRICATED OPEN WEB ROOF TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTED OTHERWISE ON PLAN 2 TRUSS ANCHORAGE PROVIDE SIMPSON 'H2.5T' HURRICANE CLIPS AT EACH TRUSS BEARING POINT GIRDER TRUSSES MAY REQUIRE ADDITIONAL ANCHORAGE AND WILL BE DETERMINED DURING SHOP DRAWING REVIEW. 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:27 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.10A Author Checker DDS-025-22 LEVEL 10 FLOOR FRAMING PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 10 FLOOR FRAMING PLAN - PART A FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB WOOD FRAMED FLOORS SCHEMATIC DESIGN ASSUMPTIONS • 18" OPEN WEB FLOOR TRUSSES W/ 23/32" APA RATED FLOOR SHEATHING TYPICALLY SPANNING FROM DEMISING WALL TO DEMISING WALL • CORRIDORS WILL BE FRAMED WITH FLOOR TRUSSES THAT PROVIDE BLOCKOUTS FOR UTILITIES • CORRIDOR, EXTERIOR, INTERIOR BEARING AND 'WET' DEMISING WALLS TO BE 2x6 STUDS WITH VARIABLE STUD SPACING • TYPICAL DEMISING WALLS TO BE 'DOUBLE' 2x4 STUDS WITH VARIABLE STUD SPACING • LATERAL FORCE RESISTANCE WILL BE FROM A COMBINATION OF EXTERIOR, CORRIDOR, AND UNIT DEMISING WALLS SHEATHED WITH PLYWOOD AND OSB (OSB ON UNIT SIDE OF DEMISING WALLS) • EXTERIOR WALLS TO BE FRT LUMBER AND SHEATHED WITH FRT PLYWOOD OR FLAMEBLOCK DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:29 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.10B Author Checker DDS-025-22 LEVEL 10 FLOOR FRAMING PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 10 FLOOR FRAMING PLAN - PART B FLOOR FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 FLOOR TRUSSES XX" DEEP PRE-FABRICATED OPEN WEB FLOOR TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTE OTHERWISE ON PLAN 2 VERTICAL CHASES TRUSS MANUFACTURER TO PROVIDE GIRDER TRUSSES AS NEEDED TO FRAME OPENINGS FOR VERTICAL CHASES COORDINATE LOCATIONS WITH ARCHITECTURAL DRAWINGS 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB XXX G.T. FRAMING PLAN LEGEND TRUSS SPAN DIRECTION INTERIOR BEARING WALL DROPPED HEADER WOOD BEARING WALL TAG4A FLUSH BEAM GIRDER TRUSS JOIST/RAFTER/TRUSS ADDITIONAL LOADING ROOF HEADER SCHEDULE LOCATION MAXIMUM CLEAR SPAN SIZE EXTERIOR WALL X'-X" TO X'-X" (X) 2xX EXTERIOR WALL CORRIDOR WALL (X) 2xX (X) 2xX X'-X" TO X'-X" X'-X" TO X'-X" 1. ALL EXTERIOR WALL OPENINGS SHALL HAVE A MINIMUM (2) JACK STUDS AND (2) KING STUDS. 2. ALL INTERIOR WALL OPENINGS SHALL HAVE A MINIMUM (2) JACK STUDS AND (1) KING STUD. WOOD BEARING WALL STUD SCHEDULE 5TH FLR. TO ROOF MARKLEVEL 2x4@XX 4A 4B 4C 6A 6B 2x4@XX 2x4@XX 2x6@XX 2x6@XX 4TH FLR. TO 5TH FLR. 2x4@XX 2x4@XX 2x4@XX 2x6@XX 2x6@XX 3RD FLR. TO 4TH FLR. 2x4@XX 2x4@XX 2x4@XX 2x6@XX 2x6@XX 2ND FLR. TO 3RD FLR. 2x4@XX 2x4@XX 2x4@XX 2x6@XX 2x6@XX 1ST FLR. TO 2ND FLR. 2x4@XX 2x4@XX 2x4@XX 2x6@XX 2x6@XX 1. ALL UNIT SEPARATION WALLS TO BE TYPE "4A", ALL INTERIOR BEARING WALLS TO BE TYPE "4B" AND ALL EXTERIOR WALLS TO BE TYPE "6A" UNLESS NOTED OTHERWISE ON PLAN. 2. ALL WET WALLS DESIGNATED AS BEARING WALLS SHALL BE 2x6 MINIMUM AND SPACED TO MATCH THE 2x4 WALL INDICATION. 3. (D) - INDICATES DOUBLE STUDS AT TRUSS BEARING LOCATIONS. 4. (T) - INDICATES TRIPLE STUDS AT TRUSS BEARING LOCATIONS. 5. STUDS SHALL ALIGN WITH TRUSSES WHEN BOTH ARE SPACED AT 16" O.C. AND WHEN TRUSSES ARE SPACED AT 12" OR 24" AND STUDS ARE SPACED AT 12" O.C. 6. PROVIDE MID-HEIGHT BLOCKING BETWEEN EVERY STUD WHERE STUD HEIGHT EXCEEDS 9'-4". 7. NON-BEARING WALLS MAY HAVE STUDS SPACED AT 24" O.C. MAXIMUM ASSUMING A TIGHTER STUD SPACING IS NOT REQUIRED BY THE OWNER, ARCHITECT, OR GENERAL CONTRACTOR. WOOD COLUMN SCHEDULE 5TH FLR. TO ROOF MARKLEVEL C1 4TH FLR. TO 5TH FLR. 3RD FLR. TO 4TH FLR. 2ND FLR. TO 3RD FLR. 1ST FLR. TO 2ND FLR. (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX C2 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX C3 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX C4 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX C5 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX WOOD FRAMED ROOF SCHEMATIC DESIGN ASSUMPTIONS • ROOF TRUSSES TYPICALLY SPANNING FROM CORRIDOR TO EXTERIOR W/ 1/4" PER FOOT TOP CHORD SLOPE. 30" MINIMUM DEPTH • 'FLAT' ROOF SHEATHED WITH 23/32" APA RATED SHEATHING DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:31 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.11A Author Checker DDS-025-22 LEVEL 11 ROOF FRAMING PLAN -PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCROOF FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ROOF TRUSSES PRE-FABRICATED OPEN WEB ROOF TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTED OTHERWISE ON PLAN 2 TRUSS ANCHORAGE PROVIDE SIMPSON 'H2.5T' HURRICANE CLIPS AT EACH TRUSS BEARING POINT GIRDER TRUSSES MAY REQUIRE ADDITIONAL ANCHORAGE AND WILL BE DETERMINED DURING SHOP DRAWING REVIEW. 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB DATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 11 ROOF FRAMING PLAN - PART A WOOD FRAMED ROOF SCHEMATIC DESIGN ASSUMPTIONS • ROOF TRUSSES TYPICALLY SPANNING FROM CORRIDOR TO EXTERIOR W/ 1/4" PER FOOT TOP CHORD SLOPE. 30" MINIMUM DEPTH • 'FLAT' ROOF SHEATHED WITH 23/32" APA RATED SHEATHING DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:32 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS03.11B Author Checker DDS-025-22 LEVEL 11 ROOF FRAMING PLAN -PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV 1/8" = 1'-0"1 LEVEL 11 ROOF FRAMING PLAN - PART B ROOF FRAMING PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 ROOF TRUSSES PRE-FABRICATED OPEN WEB ROOF TRUSSES DESIGNED BY MANUFACTURER AND SPACED AT 24" O.C. MAXIMUM UNLESS NOTED OTHERWISE ON PLAN 2 TRUSS ANCHORAGE PROVIDE SIMPSON 'H2.5T' HURRICANE CLIPS AT EACH TRUSS BEARING POINT GIRDER TRUSSES MAY REQUIRE ADDITIONAL ANCHORAGE AND WILL BE DETERMINED DURING SHOP DRAWING REVIEW. 3 GIRDER TRUSS AND FLUSH BEAM SUPPORT PROVIDE MINIMUM (3)2x STUDS UNDER EACH GIRDER TRUSS OR FLUSH BEAM BEARING POINT, U.N.O. ON PLAN PROVIDE SOLID BLOCKING WITHIN FLOOR PLENUM AND CONTINUE BUILT-UP STUDS DOWN TO ELEVATED TRANSFER SLAB -- -- -- -- -- ---- -- -- -- -- -- -- -- -------- -- -- SHEAR WALL SHEATHING ATTACHMENT SCHEDULE LEVEL WALL TYPE 1ST FLR. TO 2ND FLR. NOTES: 1. SCHEDULE INDICATES REQUIRED SPACING AT PANEL EDGES/IN PANEL FIELD RESPECTIVELY. 2. INSTALL SHEATHING ON SIDE OF WALL THAT CONTAINS SHEAR WALL TAG ON PLAN. 3. FASTENERS FOR OSB/PLYWOOD SHEATHING TO BE 8d COMMON OR GALVANIZED BOX NAILS WITH 1⅜" MINIMUM PENETRATION INTO MAIN MEMBER. 4. FASTENERS FOR 5/8" GYPSUM WALLBOARD TO BE 6d COOLER NAILS OR OTHER OPTION LISTED IN AWC "SPECIAL DESIGN PROVISIONS FOR WIND AND SEISMIC". 5. PROVIDE SOLID BLOCKING AT ALL PANEL EDGES WHERE INDICATED. 6. INSTALL SHEATHING WITH LONG DIMENSION OF PANEL PERPENDICULAR TO STUDS. 7. WHERE OSB SHEATHING PANELS ARE APPLIED ON BOTH FACES AND NAIL SPACING IS LESS THAN 6" ON CENTER ON EITHER SIDE, PANEL JOINTS SHALL BE OFFSET TO FALL ON DIFFERENT FRAMING MEMBERS. ALTERNATIVELY, THE WIDTH OF THE NAILED FACE OF FRAMING MEMBERS SHALL BE 3" NOMINAL OR GREATER AT ADJOINING PANEL EDGES AND NAILS AT ALL PANEL EDGES SHALL BE STAGGERED. 2ND FLR. TO 3RD FLR. 3RD FLR. TO 4TH FLR. 4TH FLR. TO 5TH FLR. SHEATHING MATERIAL 7/16" OSB 19/32" FRT PLYWOOD X/X BLOCKEDSW-X X/X BLOCKED X/X BLOCKED X/X BLOCKED SW-X SW-X 7/16" FIRE RATED OSB X/X UNBLOCKED 5/8" GYPSW-X X/X UNBLOCKED 5TH FLR. TO ROOF X/X BLOCKED 2ND FLOOR 3RD FLOOR 4TH FLOOR 5TH FLOOR ROOF SHEAR WALL HOLDOWN SCHEDULE LEVEL HOLDOWN DEVICE HOLDOWN DEVICE HOLDOWN DEVICE HOLDOWN DEVICE DESIGN UPLIFT DESIGN UPLIFT DESIGN UPLIFT DESIGN UPLIFT AR-1 AR-2 HD-1 HD-2 SHEAR WALL CHORD STUD SCHEDULE 5TH FLR. TO ROOF MARKLEVEL CS-1 4TH FLR. TO 5TH FLR. 3RD FLR. TO 4TH FLR. 2ND FLR. TO 3RD FLR. 1ST FLR. TO 2ND FLR. (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX CS-2 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX CS-3 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX CS-4 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX CS-5 (X) 2xX (X) 2xX (X) 2xX (X) 2xX (X) 2xX DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:34 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS04.01A Author Checker DDS-025-22 SHEAR WALL LAYOUT PLAN - PART A SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCWOOD FRAMED SHEAR WALL PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 SHEAR WALL LAYOUT PLAN 9TH LEVEL HAS BEEN SHOWN AS TYPICAL. SHEAR WALL LAYOUT SHOULD BE APPLIED TO EACH WOOD FRAMED LEVEL 2 DESIGNATED SHEAR WALLS LATERAL FORCE RESISTANCE WILL BE PROVIDED BY THE WALLS HIGHLIGHTED WITH A DASHED LINE UNIT SEPARATION WALLS INDICATED WILL HAVE SHEATHING ATTACHED WITHIN THE WALL CAVITY AND CORRIDOR WALLS INDICATED WILL BE SHEATHED ON THE UNIT SIDE 3 SHEAR WALL MATERIALS SEE ADDITIONAL SCHEDULES AND NOTES ON PLAN FOR SHEATHING MATERIALS AND ATTACHMENT 4 ANCHORAGE OR HOLDOWNS WHERE INDICATED ON PLAN, INSTALL HOLDOWN DEVICES PER THE SHEAR WALL HOLDOWN SCHEDULE ANCHOR RODS TO BE DESIGNED BY OTHERS FOR THE TOTAL FACTORED ASD UPLIFT FORCES NOTED IN THE SHEAR WALL HOLDOWN SCHEDULE. 5 CHORD STUDS (CS-X) WHERE INDICATED ON PLAN, INSTALL CHORD STUDS AS BUILT UP POSTS PER THE SHEAR WALL CHORD STUD SCHEDULE 6 CORNER DIMENSIONS CORNER DIMENSIONS SHOWN INDICATE LOCATIONS FOR 'END ZONE' COMPONENTS AND CLADDING LOADING SEE SHEET SXXX FOR ADDITIONAL LOADING INFORMATION ON INDIVIDUAL COMPONENTS DATE DESCRIPTION REV 1/8" = 1'-0"1 FR9 SHEAR WALL LAYOUT - Part A SCHEMATIC DESIGN ASSUMPTIONS: • IDENTIFIED SHEAR WALLS WILL UTILIZE 7/16" OSB SHEATHING ON THE INTERIOR AND EITHER 1/2" FRT PLYWOOD OR 7/16" CEMENTITIOUS COATED OSB (2-SIDED) SHEATHING ON THE EXTERIOR. • LAYOUT OF SHEAR WALLS WILL UTILIZE A LARGE NUMBER OF UNIT SEPARATION AND CORRIDOR WALLS (ONE SIDE OF THE CORRIDOR TO THE EXTENT POSSIBLE) AS WELL AS TARGETED EXTERIOR WALLS (FORCE TRANSFER AROUND OPENING) DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:35 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS04.01B Author Checker DDS-025-22 SHEAR WALL LAYOUT PLAN - PART B SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV WOOD FRAMED SHEAR WALL PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 SHEAR WALL LAYOUT PLAN 9TH LEVEL HAS BEEN SHOWN AS TYPICAL. SHEAR WALL LAYOUT SHOULD BE APPLIED TO EACH WOOD FRAMED LEVEL 2 DESIGNATED SHEAR WALLS LATERAL FORCE RESISTANCE WILL BE PROVIDED BY THE WALLS HIGHLIGHTED WITH A DASHED LINE UNIT SEPARATION WALLS INDICATED WILL HAVE SHEATHING ATTACHED WITHIN THE WALL CAVITY AND CORRIDOR WALLS INDICATED WILL BE SHEATHED ON THE UNIT SIDE 3 SHEAR WALL MATERIALS SEE ADDITIONAL SCHEDULES AND NOTES ON PLAN FOR SHEATHING MATERIALS AND ATTACHMENT 4 ANCHORAGE OR HOLDOWNS WHERE INDICATED ON PLAN, INSTALL HOLDOWN DEVICES PER THE SHEAR WALL HOLDOWN SCHEDULE ANCHOR RODS TO BE DESIGNED BY OTHERS FOR THE TOTAL FACTORED ASD UPLIFT FORCES NOTED IN THE SHEAR WALL HOLDOWN SCHEDULE. 5 CHORD STUDS (CS-X) WHERE INDICATED ON PLAN, INSTALL CHORD STUDS AS BUILT UP POSTS PER THE SHEAR WALL CHORD STUD SCHEDULE 6 CORNER DIMENSIONS CORNER DIMENSIONS SHOWN INDICATE LOCATIONS FOR 'END ZONE' COMPONENTS AND CLADDING LOADING SEE SHEET SXXX FOR ADDITIONAL LOADING INFORMATION ON INDIVIDUAL COMPONENTS 1/8" = 1'-0"1 FR9 SHEAR WALL LAYOUT - Part B SCHEMATIC DESIGN ASSUMPTIONS: • IDENTIFIED SHEAR WALLS WILL UTILIZE 7/16" OSB SHEATHING ON THE INTERIOR AND EITHER 1/2" FRT PLYWOOD OR 7/16" CEMENTITIOUS COATED OSB (2-SIDED) SHEATHING ON THE EXTERIOR. • LAYOUT OF SHEAR WALLS WILL UTILIZE A LARGE NUMBER OF UNIT SEPARATION AND CORRIDOR WALLS (ONE SIDE OF THE CORRIDOR TO THE EXTENT POSSIBLE) AS WELL AS TARGETED EXTERIOR WALLS (FORCE TRANSFER AROUND OPENING) DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:36 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS04.01C Author Checker DDS-025-22 SHEAR WALL LAYOUT PLAN - PART C SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCDATE DESCRIPTION REV WOOD FRAMED SHEAR WALL PLAN NOTES ELEMENT: INFORMATION:ADDITIONAL COMMENTS: 1 SHEAR WALL LAYOUT PLAN 9TH LEVEL HAS BEEN SHOWN AS TYPICAL. SHEAR WALL LAYOUT SHOULD BE APPLIED TO EACH WOOD FRAMED LEVEL 2 DESIGNATED SHEAR WALLS LATERAL FORCE RESISTANCE WILL BE PROVIDED BY THE WALLS HIGHLIGHTED WITH A DASHED LINE UNIT SEPARATION WALLS INDICATED WILL HAVE SHEATHING ATTACHED WITHIN THE WALL CAVITY AND CORRIDOR WALLS INDICATED WILL BE SHEATHED ON THE UNIT SIDE 3 SHEAR WALL MATERIALS SEE ADDITIONAL SCHEDULES AND NOTES ON PLAN FOR SHEATHING MATERIALS AND ATTACHMENT 4 ANCHORAGE OR HOLDOWNS WHERE INDICATED ON PLAN, INSTALL HOLDOWN DEVICES PER THE SHEAR WALL HOLDOWN SCHEDULE ANCHOR RODS TO BE DESIGNED BY OTHERS FOR THE TOTAL FACTORED ASD UPLIFT FORCES NOTED IN THE SHEAR WALL HOLDOWN SCHEDULE. 5 CHORD STUDS (CS-X) WHERE INDICATED ON PLAN, INSTALL CHORD STUDS AS BUILT UP POSTS PER THE SHEAR WALL CHORD STUD SCHEDULE 6 CORNER DIMENSIONS CORNER DIMENSIONS SHOWN INDICATE LOCATIONS FOR 'END ZONE' COMPONENTS AND CLADDING LOADING SEE SHEET SXXX FOR ADDITIONAL LOADING INFORMATION ON INDIVIDUAL COMPONENTS 1/8" = 1'-0"1 FR9 SHEAR WALL LAYOUT - Part C SCHEMATIC DESIGN ASSUMPTIONS: • IDENTIFIED SHEAR WALLS WILL UTILIZE 7/16" OSB SHEATHING ON THE INTERIOR AND EITHER 1/2" FRT PLYWOOD OR 7/16" CEMENTITIOUS COATED OSB (2-SIDED) SHEATHING ON THE EXTERIOR. • LAYOUT OF SHEAR WALLS WILL UTILIZE A LARGE NUMBER OF UNIT SEPARATION AND CORRIDOR WALLS (ONE SIDE OF THE CORRIDOR TO THE EXTENT POSSIBLE) AS WELL AS TARGETED EXTERIOR WALLS (FORCE TRANSFER AROUND OPENING) SEE NOTE 2 NOTES: 1. SEE SHEAR WALL LAYOUT PLAN FOR HOLDOWN REQUIREMENTS AT LOWEST FLOOR. 2. ADD ADDITIONAL STUDS AS NEEDED TO PROVIDE REQUIRED NUMBER OF CHORD STUDS NOTED IN CHORD STUD SCHEDULE. 3. SEE SHEAR WALL LAYOUT PLAN FOR STRAP REQUIREMENTS ACROSS FLOOR PLENUM. 4. PROVIDE SHEATHING IN WALL CAVITY AS REQUIRED PER SHEAR WALL LAYOUT PLANS AND NOTES. 5. COORDINATE SHEATHING AND ATTACHMENT WITH SCHEDULES AND PLAN NOTES. 6. SEE SHEAR WALL END ELEVATION DETAIL FOR ADDITIONAL INFORMATION. 7. WALL CORNERS AND INTERSECTIONS TO BE FRAMED SIMILAR AT INTERIOR CONDITION. SEE NOTE 1 SEE NOTE 4 UNIT SEPARATION WALL AT EXTERIOR WALL SEE NOTE 2 INTERIOR BEARING WALL AT EXTERIOR WALL SEE NOTE 2 INTERIOR BEARING WALL AT EXTERIOR WALL SEE NOTE 2 SEE NOTE 1 SEE NOTE 4 UNIT SEPARATION WALL AT EXTERIOR CORNER SEE NOTE 2 SEE NOTE 2 SEE NOTE 3 EXTERIOR WALL CORNER SEE NOTE 1 SEE NOTE 3 SEE NOTE 3 SEE NOTE 3 SEE NOTE 3 SEE NOTE 1 SEE NOTE 2 SEE NOTE 1 SEE NOTE 1 DOUBLE 2x TOP PLATE 12"12"DOUBLE 2x TOP PLATE PROVIDE SIMPSON 'CS16' COIL STRAP WITH 10d NAILS ACROSS NON-CONTINUOUS TOP PLATE FASTEN END STUDS TOGETHER PER TYPICAL BUILT UP WOOD POST DETAIL NOTE: FLOOR AND CEILING ASSEMBLY NOT SHOWN FOR CLARITY. INTERSECTION 2x EXTERIOR WALL BEYOND 2x INTERIOR SHEAR WALL 2x EXTERIOR SHEAR WALL NOTES: 1. NOTED AS 'FTAO' (FORCE TRANSFER AROUND OPENINGS) ON SHEAR WALL LAYOUT PLANS. 2. SEE SHEAR WALL SCHEDULES FOR CHORD STUD, ANCHOR AND EXTERIOR SHEATHING REQUIREMENTS. WALL OPENING DOUBLE 2x TOP PLATE SINGLE 2x BOTTOM/SILL PLATE SIMPSON 'CS16' COIL STRAP LOCATED ON INTERIOR FACE OF WALL ATTACHED TO 2x BLOCKING BETWEEN STUDS AT EACH CORNER OF OPENING 12" TYP. ATTACH EXTERIOR SHEATHING TO BLOCKING PER EDGE NAILING NOTED IN SHEAR WALL SHEATHING ATTACHMENT SCHEDULE SIMPSON 'CS16' COIL STRAP LOCATED ON INTERIOR FACE OF WALL ATTACHED TO 2x BLOCKING BETWEEN STUDS AT EACH CORNER OF OPENING, ATTACH PER MANUFACTURER RECOMMENDATIONS A A A-A TRUSS MANUFACTURER TO PROVIDE SHEAR PANELS SPACED AT 24" O.C. AT 5TH AND 6TH FLOOR, AND 48" O.C. AT 7TH AND 8TH FLOOR FOR A SHEAR LOAD OF 500 PLF SHEAR WALL, SEE SHEAR WALL LAYOUT PLANS FOR LOCATIONS SHEAR WALL, SEE SHEAR WALL LAYOUT PLANS FOR LOCATIONS NOTE: SHEAR PANELS CAN BE SUBSTITUTED WITH 1 1/4" LSL PANELS TO MATCH FLOOR TRUSS DEPTH. TOENAIL PERIMETER OF SHEAR PANEL TO ADJACENT FRAMING WITH 10d NAILS SPACED AT 4" O.C. TRUSS MANUFACTURER TO PROVIDE CONTINUOUS BEARING SHEAR TRUSS AT LOCATIONS INDICATED ON PLAN FOR A SHEAR LOAD OF XXX PLF SHEAR WALL, SEE SHEAR WALL LAYOUT PLANS FOR LOCATIONS SHEAR WALL, SEE SHEAR WALL LAYOUT PLANS FOR LOCATIONS NOTES: 1. PROVIDE REQUIRED NUMBER OF CHORD STUDS NOTED IN CHORD STUD SCHEDULE. 2. STRAP END LENGTHS TO MEET MANUFACTURER SPECIFICATIONS TO DEVELOP FULL LISTED LOAD. 3. ATTACH HOLDOWN TO CONCRETE WITH XX"Ø FOR HD-1 AND XX"Ø HD-2. HOLDOWN PER SCHEDULE STRAP ACROSS FLOOR PLENUM PER HOLDOWN SCHEDULE, SLOT FLOOR SHEATHING AND LOCATED STRAP ON INTERIOR SIDE OF WALL COORDINATE FLOOR FRAMING WITH FRAMING PLANS VERTICAL CRIPPLE BLOCKING TO MATCH SIZE AND QUANTITY OF CHORD STUDS BELOWSEENOTE 2SEENOTE 2SEE NOTE 1 CONCRETE LEVEL TYPICAL WOOD FLOOR LEVEL SEE NOTE 1 SEENOTE 3DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:37 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS04.11 MG,GK,MS MJS DDS-025-22 SHEAR WALL DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"1 SHEAR WALL INTERSECTIONS - HOLDOWNS 3/4" = 1'-0"2 TOP PLATE STRAP AT EXTERIOR SHEAR WALL 1/2" = 1'-0"3 FORCE TRANSFER AROUND OPENINGS 3/4" = 1'-0"4 SHEAR PANELS - INTERIOR BEARING SHEAR WALL 3/4" = 1'-0"5 SHEAR TRUSS - CONTINUOUS BEARING 1/2" = 1'-0"6 SHEAR WALL END ELEVATION - HOLDOWNS DATE DESCRIPTION REV DOUBLE 2x4 BLOCKING BETWEEN EACH TRUSS VERTICAL 2x4 BLOCKING ATTACHED TO TRUSS WITH (6) 10d NAILS TRUSS MANUFACTURER TO PROVIDE (2) 2x4 VERTICAL AT OFFSET BEARING WALL LOCATIONS A-A A A NOTE: CONTINUE STRONGBACKS TO PERPENDICULAR WALLS AND ATTACH TO VERTICAL 2x4 BLOCKS. TYPICAL SPLICE BUTT STRONGBACK ENDS TOGETHER 2x6 SCAB ATTACHED WITH (2) ROWS 10d NAILS SPACED AT 6" O.C., EXTEND 2'-0" MINIMUM EACH SIDE OVERLAP MINIMUM 2'-0" AND ATTACH WITH (2) ROWS 10d NAILS SPACED AT 6" O.C. 2x4 VERTICAL BLOCK WITH (2) 10d NAILS TOP AND BOTTOM CHORDS AND WEB INTERSECTION 2x6 STRONGBACK TO BE INSTALLED WITH VERTICAL BLOCK WHEN TRUSS VERTICALS DO NOT ALIGN INSTALL STRONGBACK TIGHT TO BOTTOM CHORD (3) 10d NAILS, TYPICAL UP TO 10' NOT REQUIRED 10' TO 20' 20' TO 30' (1) ROW LOCATED CENTER OF SPAN (2) ROWS, (1) AT EACH THIRD POINT STRONGBACK SPACING SCHEDULE EXTERIOR AND BEARING WALLS ALLOWABLE CUTTING AND NOTCHING 1 3/8" MAX 5 1/2"MAX3 1/2"MAX7/8" MAX 3 1/2" 5 1/2" 2x4 STUD 2x6 STUD NON-BEARING WALLS DEPTH SHALL NOT EXCEED 25% OF WIDTH DEPTH SHALL NOT EXCEED 40% OF WIDTH BORED STUD REQUIREMENTS **NON-BEARING WALLS OR WHEN SPECIFIED WALL STUD QUANTITY IS DOUBLED HOLE DIAMETER SHALL NOT EXCEED 40% OF WIDTH*SPECIFIED WALL STUD QUANTITY HOLE DIAMETER SHALL NOT EXCEED 60% OF WIDTH 3 1/2" *SINGLE 2x4 STUD 3 1/2" **DOUBLE 2x4 STUD *SINGLE 2x6 STUD 5 1/2" **DOUBLE 2x6 STUD 5 1/2" 5/8" MIN 1 3/8" MAX 5/8" MIN 2" MAX 5/8" MIN 2 1/8" MAX 5/8" MIN 3 1/4" MAX NOTES: 1. REFERENCE IBC SECTION 2308.5.9 FOR ALLOWABLE CUTTING AND NOTCHING REQUIREMENTS AND 2308.5.10 FOR BORED STUD REQUIREMENTS. 2. TRIPLE STUDS SHALL NOT BE BORED MORE THAN 40%. 3. WOOD POST SHALL NOT BE NOTCHED OR BORED. 4. MULTIPLE CUTS, NOTCHES OR BORED HOLES SHALL NOT OCCUR IN THE SAME CROSS SECTION OF THE STUD. 5. CUTS, NOTCHES OR BORED HOLES SHALL NOT OCCUR IN MORE THAN TWO SUCCESSIVE STUDS. 6. CONTACT SER PRIOR TO CUTTING, NOTCHING OR BORING STUDS IF THESE LIMITATIONS CANNOT BE MET. 7. ALL EXTERIOR WALL WOOD FRAMING TO BE FIRE RETARDANT TREATED. NOTE: 1. REFERENCE IBC SECTION 2308.4.2.4 AND 2308.7.4 FOR JOIST AND RAFTER HOLE SIZE REQUIREMENTS. 2. DIAGRAM IS FOR UNIFORMLY LOADED BEAM ONLY. 3. RECTANGULAR HOLES ARE NOT PERMITTED. 4. CONTACT SER IF LOCATION AND SIZE OF HOLES DIFFER THAN THOSE SHOWN AND MEET THE DIAGRAM REQUIREMENTS.1/3 D 1/3 D 1/3 D 1/3 SPAN 1/3 SPAN 1/3 SPAN SPANDALLOWABLE HOLE ZONE ALLOWABLE HOLE ZONE 2x DIAMETER OF LARGEST HOLE (MINIMUM) SUPPORT SUPPORT 5 1/2" TO 9 1/4" MEMBER DEPTH MAXIMUM ROUND HOLE SIZE UP TO 20" 1 1/2" 2" UNIT SEPARATION WALL INTERIOR BEARING WALL PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL 2x4 RIBBON BEYOND PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL PLUMBING PENETRATION, SEE PLUMBING DRAWINGS FOR LOCATIONS (2) SIMPSON 'RPS18' STRAP TIES AT BORED HOLES LARGER THAN 1 1/2" IN 2x4 PLATES OR 2 1/2" IN 2x6 PLATES PLUMBING PENETRATION, SEE PLUMBING DRAWINGS FOR LOCATIONS (2) SIMPSON 'RPS18' STRAP TIES AT BORED HOLES LARGER THAN 1 1/2" IN 2x4 PLATES OR 2 1/2" IN 2x6 PLATES NOTE: SIMPSON 'CS16' COIL STRAPS, 24" LONG, WITH 10d NAILS ARE A STRUCTURALLY ACCEPTABLE SUBSTITUTION FOR THE 'RPS18' STRAP TIES. GC TO VERIFY PROPER PIPE PROTECTION IS ACHIEVED IF THIS SUBSTITUTION IS USED. DOUBLE 2x TOP PLATE 12"12" 2x BLOCKING BETWEEN (2) WALL STUDS MINIMUM DOUBLE 2x TOP PLATE PROVIDE SIMPSON 'CS16' COIL STRAP WITH 10d NAILS ACROSS LOWER WALL TOP PLATE AND ADJACENT 2x BLOCKING FASTEN END STUDS TOGETHER PER TYPICAL BUILT UP WOOD POST DETAIL NOTE: 1. FLOOR AND CEILING ASSEMBLY NOT SHOWN FOR CLARITY. 2. ALL EXTERIOR WALL WOOD FRAMING TO BE FIRE RETARDANT TREATED. FASTEN EACH PLY TOGETHER WITH 10d NAILS SPACED AT 12" O.C., STAGGER NAIL EACH FACE NOTES: 1. NAILING REQUIREMENTS APPLY TO ALL BUILT UP WOOD POSTS, INCLUDING JACK AND KING STUDS, WOOD COLUMNS AND SHEAR WALL CHORD STUDS. 2. SHEATHING MAY BE GYPSUM WALLBOARD OR WOOD STRUCTURAL PANEL. COORDINATE WITH TYPICAL SHEATHING AND SHEAR WALL SHEATHING ATTACHMENT SCHEDULE. 3. ALL EXTERIOR WALL WOOD FRAMING TO BE FIRE RETARDANT TREATED. (2) 2x (3) 2x (4) 2x (5) 2x SHEATHING FASTENING PER NOTE 2 ADDITIONAL LINE OF SHEATHING FASTENERS AT OUTER STUDS FOR (4)2x BUILT UP WOOD POST OR LARGER FACE NAIL OUTER PLIES TO (2)2x WITH 10d NAILS SPACED AT 12" O.C. FOR (3)2x BUILT UP WOOD POST OR LARGER FLUSH GIRDER TRUSS FLUSH 2x OR LVL 1/2" MAX 1/2" MAX TOP CHORD BEARING CONDITION TO BE APPLIED TO SHORTER SPAN OF TWO TRUSSES TOP CHORD BEARING CONDITION TO BE APPLIED TO SHORTER SPAN OF TWO TRUSSES GIRDER TRUSS GIRDER TRUSS TO MATCH DEPTH OF FLOOR TRUSSES HANGER BY TRUSS MANUFACTURER, BOTH SIDES HANGER BY TRUSS MANUFACTURER, ONE SIDE FLUSH BEAM TO MATCH DEPTH OF FLOOR TRUSSES FLUSH BEAM PLACED DIRECTLY ON WALL TOP PLATES HANGER, ONE SIDE SHIM TRUSS AT BEARING AS REQUIRED HANGER, BOTH SIDES 3"NOTE: STAGGERED TOP CHORD BEARING TRUSSES ARE PERMITTED ON BOTH SIDES OF FLUSH BEAM/GIRDER TRUSS. ELEVATION NOTE: 1. PROVIDE SIMPSON 'CS16' WITH 10d NAILS AND 12" END LENGTHS WHERE 4'-0" SPLICE IS NOT MAINTAINED. 2. ALL EXTERIOR WALL WOOD FRAMING TO BE FIRE RETARDANT TREATED. PLAN VIEW STAGGER SPLICES 4' - 0" MINIMUM 6"1/2"MIN.(14)10d NAILS STUD EACH SIDE OF SPLICE IN LOWER TOP PLATE STUD UNDER SPLICE IN UPPER TOP PLATE UNIT SEPARATION/EXTERIOR WALL INTERIOR BEARING WALL TRUSS MANUFACTURER TO PROVIDE PRE-CUT (2)2x4 CRIPPLE STUD CENTERED BETWEEN EACH TRUSS 2x4 RIBBON BEYOND 2x6 FRAMED WALL SHOWN HIDDEN 2x4 RIBBON TRUSS MANUFACTURER TO PROVIDE PRE-CUT CRIPPLE STUD TIGHT TO UNDERSIDE OF SHEATHING, CENTERED BETWEEN EACH TRUSS TO MATCH QUANTITY OF WALL STUDS ABOVE (1) 2x4 TIGHT TO UNDERSIDE OF RIBBON, (1) 2x4 TIGHT TO UNDERSIDE OF SHEATHING EQ EQ EQ EQ WOOD POST ALIGNED WITH TRUSS PROVIDE TRANSFER BLOCKING IN EACH FLOOR PLENUM TO MATCH WOOD POST QUANTITY ABOVE SEE NOTE 4 NOTES: 1. PROVIDE SOLID VERTICAL BLOCKING TO TRANSFER ALL POINT LOADS ACROSS FLOOR PLENUM. 2. VERIFY ALIGNMENT AND TIGHTNESS OF FRAMING TO FORM A CONTINUOUS LOAD PATH DOWN THROUGH THE BUILDING TO THE FOUNDATION OR SUPPORTING TRANSFER ELEMENT BELOW. 3. TRANSFER BLOCKING SIZE SHALL COVER EVERY PORTION OF POST FOOTPRINT ABOVE. 4. ONLY BOTTOM CHORD BEARING TRUSSES WITH (2) 2x4 VERTICAL MEMBERS ALIGNED WITH BEARING WALL AID IN LOAD TRANSFER. CONTACT TRUSS MANUFACTURER FOR REPAIR IF POSTS ALIGN ELSEWHERE ALONG THE LENGTH OF THE TRUSS. 5. TRANSFER BLOCKING SHALL OCCUR WITHIN THE TOP AND BOTTOM CHORD AT LOCATIONS WITH A LADDER TRUSS. WOOD POST NOT ALIGNED WITH TRUSS WOOD POST PARTIALLY ALIGNED WITH TRUSS 2x4 RIBBON BEYOND AS REQUIRED NOTCH TRANSFER BLOCKING AT RIBBON LOCATIONS ROUGH OPENING JACK AND KING STUDS, SEE FLOOR HEADER SCHEDULE ON FLOOR FRAMING PLANS HEADER PER SCHEDULE ALTERNATE HEADER LOCATION IF PENETRATIONS ARE NEEDED AT EXTERIOR WALL OVER WINDOW/DOOR AT WINDOW OPENINGS, PROVIDE (1) 2x SILL FOR SINGLE AND DOUBLE OPENING AND (2) 2x SILL AT TRIPLE OR LARGER OPENINGS JACK AND KING STUDS, SEE FLOOR HEADER SCHEDULE ON FLOOR FRAMING PLANS TYPE IIIA NOTES: 1. ALL EXTERIOR WALL WOOD FRAMING TO BE FIRE RETARDANT TREATED. ROUGH OPENING JACK AND KING STUDS, SEE FLOOR HEADER SCHEDULE ON FLOOR FRAMING PLANS HEADER PER SCHEDULE PROVIDE TRANSFER BLOCKING AT POST TRANSFER LOCATIONS PER TYPICAL DETAIL PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL 2x FRAMING TO PROPER WALL OPENING HEIGHT GRILLE OVER DOOR, REMOVE 2x FRAMING AS NEEDED, SEE MECHANICAL DRAWINGS FOR LOCATIONS JACK AND KING STUDS, SEE FLOOR HEADER SCHEDULE ON FLOOR FRAMING PLANS ROUGH OPENING WOOD POST PER SCHEDULE FLUSH BEAM/GIRDER TRUSS, SEE TYPICAL DETAIL WOOD POST PER SCHEDULE PROVIDE TRANSFER BLOCKING ABOVE ENDS OF FLUSH BEAM/GIRDER TRUSS WHEN NOT FULL DEPTH OF FLOOR FRAMING TO MATCH WOOD POST QUANTITY ABOVE PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL FLAT 2x4 BLOCKING SPACED AT 24" O.C. NOTE: DETAIL TO BE UTILIZED WHEN NON-BEARING WALL EXCEEDS 8'-0" IN LENGTH. INTERIOR NON-LOAD BEARING WALL INTERIOR NON-LOAD BEARING WALL FLAT 2x4 BLOCKING SPACED AT 24" O.C. FLAT 2x4 BLOCKING SPACED AT 24" O.C. WHEN 'S' IS ≤ 27" WHEN 27" < 'S' ≤ 30" 'S' 'S' 2x4 LADDER FRAMING SPACED AT 24" O.C.2x4 LEDGER ON EACH END OF OVERSPACED TRUSS BAY FASTENED TO TRUSS WITH 10d NAILS SPACED AT 12" O.C. NOTE: WHEN 'S' EXCEEDS 30", CONTACT SER FOR REPAIR. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:38 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS05.11 MG,GK,MS MJS DDS-025-22 TYPICAL WOOD FRAMING DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"16 OFFSET BEARING WALL SUPPORTED BY TRUSS 3/4" = 1'-0"1 STRONGBACK DETAIL 3/4" = 1'-0"2 WOOD STUD ALLOWABLE NOTCH AND BORED HOLE SIZE 3/4" = 1'-0"3 WOOD BEAM/HEADER/JOIST/RAFTER ALLOWABLE HOLE SIZE 3/4" = 1'-0"4 TOP PLATE STRAP AT BORED HOLES 3/4" = 1'-0"5 TOP PLATE STRAP AT CHANGE IN HEIGHT 3/4" = 1'-0"6 BUILT UP WOOD POST 3/4" = 1'-0"7 FLUSH BEAM/GIRDER TRUSS 3/4" = 1'-0"8 TOP PLATE SPLICE - SAME WALL THICKNESS 3/4" = 1'-0"9 CRIPPLE STUDS AT BEARING WALLS 3/4" = 1'-0"10 POST TRANSFER BLOCKING AT FLOOR LEVEL 3/4" = 1'-0"11 WALL OPENING AT EXTERIOR WINDOW/DOOR 3/4" = 1'-0"12 WALL OPENING AT INTERIOR BEARING WALL 3/4" = 1'-0"13 WALL OPENING AT FLUSH BEAM 3/4" = 1'-0"14 NON-BEARING WALL SUPPORT 3/4" = 1'-0"15 OVERSPACED TRUSS DETAIL DATE DESCRIPTION REV TYPE IIIA, TRUSSES PARALLEL PROVIDE 1/8" MINIMUM GAP AT ALL SHEATHING EDGES PROVIDE 2x FRT BLOCKING AT ALL EXTERIOR SHEATHING EDGES 2x NAILER FOR CEILING ATTACHMENT ALTERNATE HEADER LOCATION PER TYPICAL DETAIL FRT SHEATHING 4' - 0" MINIMUM NOTES: 1. ALL EXTERIOR WALL WOOD FRAMING TO BE FIRE RETARDANT TREATED TYPE IIIA, TRUSSES PERPENDICULAR PROVIDE 1/8" MINIMUM GAP AT ALL SHEATHING EDGES PROVIDE 2x FRT BLOCKING AT ALL EXTERIOR SHEATHING EDGES 2x BLOCKING AT FRT/OSB SHEATHING TRANSITION IF NOT T&G LOCKING USP 'FWH' OR SIMPSON 'DG' HANGER ALTERNATE HEADER LOCATION PER TYPICAL DETAIL FRT SHEATHING 4' - 0" MINIMUM NOTES: 1. ALL EXTERIOR WALL WOOD FRAMING TO BE FIRE RETARDANT TREATED TOP CHORD BEARING CONDITION TO BE APPLIED TO SHORTER SPAN OF TWO TRUSSES PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL NOTE: PIGGYBACK CONDITION SHOWN. TRUSS MAY BE CONTINUOUS WITH MINIMUM DOUBLE VERTICAL AT 2x4 INTERIOR BEARING LOCATION AND TRIPLE VERTICAL AT 2x6 INTERIOR BEARING LOCATION, UNLESS SPAN ARROWS SHOWN ON PLAN APPEAR ON BOTH SIDES OF WALL. 1/2" MAX CONTINUOUS 7/16" OSB NAILED TO TRUSS VERTICAL, RIBBON, CRIPPLE STUDS AND FLAT BLOCKING WITH 8d NAILS SPACED AT 4" O.C. ALONG ALL EDGES 2x4 FLAT BLOCKING BETWEEN EACH TRUSS 2x8 TOP PLATE OSB SHEATHING, COORDINATE THICKNESS, LOCATION AND ATTACHMENT WITH SHEAR WALL LAYOUT PLAN AND SCHEDULES PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL 2x4 RIBBON CONTINUOUS 7/16" OSB NAILED TO TRUSS VERTICALS, TOP AND BOTTOM CHORD WITH 8d NAILS SPACED AT 4" O.C. ALONG ALL EDGES 2x8 TOP PLATE PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL LADDER TRUSS WITH VERTICALS SPACED TO MATCH SPACING OF WALL STUDS ABOVE 2x4 RIBBON OSB SHEATHING, COORDINATE THICKNESS, LOCATION AND ATTACHMENT WITH SHEAR WALL LAYOUT PLAN AND SCHEDULES 2x4 BLOCKING BETWEEN EACH TRUSS 3-HR RATED WALL, SEE ARCH FOR SPECIFICATIONS AND REQUIREMENTS PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL 2x4 RIBBON 2x4 BLOCKING BETWEEN EACH TRUSS PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL 2x4 RIBBON LADDER TRUSS WITH VERTICALS SPACED TO MATCH SPACING OF WALL STUDS ABOVE 3-HR RATED WALL, SEE ARCH FOR SPECIFICATIONS AND REQUIREMENTS TRUSSES PERPENDICULAR 2x NAILER FOR CEILING ATTACHMENT TOP CHORD BEARING CORRIDOR TRUSS 2x10 LEDGER WITH (2) ROWS OF SIMPSON SDWS22500DB SCREWS AT 12" O.C. PROVIDE CRIPPLE STUDS BETWEEN EACH TRUSS PER TYPICAL DETAIL 2x4 FLAT BLOCKING BETWEEN EACH TRUSS, ATTACH BLOCKING TO TOP PLATE WITH 12d NAILS SPACED AT 6" O.C. AT SHEAR WALL LOCATIONS 2x4 RIBBON CONTINUOUS 7/16" OSB SHEAR BLOCKING NAILED TO TRUSS VERTICAL, RIBBON, CRIPPLE STUDS AND FLAT BLOCKING WITH 8d NAILS SPACED AT 4" O.C. ALONG ALL EDGES NOTES: 1. FOR LEDGER ATTACHMENT, PROVIDE MINIMUM 1 1/2" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. 2. LEDGER SCREWS SHALL BE DRIVEN INTO WIDE FACE OF (2)2x4 CRIPPLE BLOCKING OR TRUSS END VERTICALS WHEN FLOOR FRAMING IN PERPENDICULAR TO CORRIDOR WALL. 3. LOAD FROM SPRINKLER PIPES SHALL NOT EXCEED 250 LBS ON ANY TRUSS. MAXIMUM SPRINKLER PIPE HANGER SPACING FOR SCHEDULE 40 PIPE SHALL NOT EXCEED 5'-4" FOR 8" DIA. AND 8'-0" FOR 6" DIA. PROVIDE BLOCKOUT FOR MECH DUCT TRUSSES PARALLEL 2x NAILER FOR CEILING ATTACHMENT 2x NAILER FOR CEILING ATTACHMENT CONTINUOUS 7/16" OSB SHEAR BLOCKING NAILED TO CORRIDOR TRUSS VERTICALS AND 2X BLOCKING WITH 8d NAILS SPACED AT 4" O.C. ALONG ALL EDGES 2x4 BLOCKING AT TOP AND BOTTOM OF CORRIDOR TRUSS PROVIDE (3) TRUSS END VERTICALS NOTES: 1. LOAD FROM SPRINKLER PIPES SHALL NOT EXCEED 250 LBS ON ANY TRUSS. MAXIMUM SPRINKLER PIPE HANGER SPACING FOR SCHEDULE 40 PIPE SHALL NOT EXCEED 5'-4" FOR 8" DIA. AND 8'-0" FOR 6" DIA. 2. SIDE MOUNT SPRINKLER PIPE SUPPORT TO CORRIDOR TRUSS TOP CHORD PROVIDE BLOCKOUT FOR MECH DUCT PROIDE HORIZ. 2x4 BLOCKING AT 4' - 0" MIN. BETWEEN INTERSECTING WALLS. EXTEND BACK TWO TRUSS BAYS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:38 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS05.12 MG,GK,MS MJS DDS-025-22 WOOD FRAMING DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"1 EXTERIOR WALL 3/4" = 1'-0"2 EXTERIOR WALL 3/4" = 1'-0"3 INTERIOR BEARING WALL - BOTH SIDES BEARING 3/4" = 1'-0"4 UNIT SEPARATION WALL - BOTH SIDES BEARING 3/4" = 1'-0"5 UNIT SEPARATION WALL - ONE SIDE BEARING 3/4" = 1'-0"6 FIRE WALL - BOTH SIDES BEARING 3/4" = 1'-0"7 FIRE WALL - ONE SIDE BEARING 3/4" = 1'-0"9 CORRIDOR WALL 3/4" = 1'-0"8 CORRIDOR WALL DATE DESCRIPTION REV EXTERIOR WALL PROVIDE SKEWED SIMPSON 'HHUS210-3' HANGER PROVIDE SIMPSON 'HUC210-2' CONCEALED FLANGE HANGER WITH MAX NAILING 2x BALCONY JOISTSBEAM, SEE PLAN BEAM, SEE PLANPROVIDE SIMPSON 'HUC210-3' CONCEALED FLANGE HANGER WITH MAX NAILING EXTERIOR WALL2x BALCONY JOISTSEXTERIOR WALLDOUBLE LEDGERPROVIDE SKEWED SIMPSON 'HU210-2' HANGER CANT.EXTERIOR WALLPROVIDE MIN. (2) JACKS UNDER EXTERIOR WALL HEADER PER SCHEDULE OR PER PLAN PROVIDE 2x BLOCKING TO MATCH JOIST DEPTH PLACED AT 45 DEGREES AND ATTACHED TO JOISTS AT EACH END WITH (3) 10d TOENAILS, ATTACH DECK BOARDS FROM ABOVE WITH (2) SCREWS MINIMUM 4' - 0"2x BLOCKING2x BLOCKINGBEAM, SEE PLAN BEAM, SEE PLANBEAM, SEE PLAN2x EXTERIOR WALL 2x BALCONY JOISTSPROVIDE SIMPSON 'HUC210-3' CONCEALED FLANGE HANGER WITH MAX NAILING ON EACH END 2x LEDGER TO MATCH JOIST DEPTH FLOOR TRUSS MANUF. TO PROVIDE POCKET FOR BEAM (TYP.) (4)2x6 TYPICAL, W/ ADDITIONAL STUD AT FIRST FRAMED LEVEL PROVIDE MIN. (2) JACKS UNDER EXTERIOR WALL HEADER PER SCHED. OR PER PLAN (4)2x6 TYPICAL, W/ ADDITIONAL STUD AT FIRST FRAMED LEVEL NOTE: SEE DETAILS 3 AND 4 ON SHEET S503A FOR SECTION THROUGH CANTILEVERED BALCONY TYPE IIIA, TRUSSES PARALLEL PROVIDE 1/8" MINIMUM GAP AT ALL SHEATHING EDGES SEE ARCH FOR DECKING INFORMATION PROVIDE 2x FRT BLOCKING AT ALL EXTERIOR SHEATHING EDGES 2x NAILER FOR CEILING ATTACHMENT ALTERNATE HEADER LOCATION PER TYPICAL DETAIL 2x10 JOISTS AT 16" O.C. WITH SIMPSON LUS28 EACH END 2x10 LEDGER WITH (2) ROWS OF SIMPSON SDWS22500DB SCREWS AT 12" O.C. NOTE: FOR LEDGER ATTACHMENT, PROVIDE MINIMUM 1½" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. SEE DETAIL 1 ON SHEET S502 FOR ADDITIONAL INFORMATION TYPE IIIA, TRUSSES PERPENDICULAR USP 'FWH' OR SIMPSON 'DG' HANGER PROVIDE 1/8" MINIMUM GAP AT ALL SHEATHING EDGES SEE ARCH FOR DECKING INFORMATION PROVIDE 2x FRT BLOCKING AT ALL EXTERIOR SHEATHING EDGES 2x BLOCKING AT FRT/OSB SHEATHING TRANSITION IF NOT T&G LOCKING ALTERNATE HEADER LOCATION PER TYPICAL DETAIL 2x10 JOISTS AT 16" O.C. WITH SIMPSON LUS28 EACH END 2x10 LEDGER WITH (2) ROWS OF SIMPSON SDWS22500DB SCREWS AT 12" O.C. NOTE: FOR LEDGER ATTACHMENT, PROVIDE MINIMUM 1½" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. SEE DETAIL 2 ON SHEET S502 FOR ADDITIONAL INFORMATION SEE ARCH FOR DECKING INFORMATION SEE ARCH FOR RAILING TYPE AND INFORMATION, SUBMIT SHOP DRAWINGS OF RAILING DESIGN AND ATTACHMENT FOR REVIEW P.T. 2x BLOCKING AT RAILING LOCATIONS FOR RAILING ATTACHMENT SEE PLAN FOR BALCONY BEAM SIZE BEAM, SEE PLAN 2x EXTERIOR WALL 2x BALCONY JOISTSPROVIDE SIMPSON 'HUC210-3' CONCEALED FLANGE HANGER WITH MAX NAILING ON EACH END 2x LEDGER TO MATCH JOIST DEPTH DOUBLE 2x LEDGER TO MATCH END BEAM DEPTH. ATTACH TO WALL STUDS W/ SIMPSON 'SDWS' SCREWS AT 'XXX' PROVIDE (4)2x6 POST AT CORNER INVERTED SIMPSON HANGER PER PLAN (4) 3/4" Ø THRU BOLTS (3) ROWS OF SIMPSON SDWS221000DB SCREWS AT 12" O.C. REMAINDER OF LEDGER FULL HEIGHT BUILT UP POST AT BOLT LOCATIONS P.T. 2x BLOCKING AT RAILING LOCATIONS FOR RAILING ATTACHMENT SEE ARCH FOR DECKING INFORMATION SEE ARCH FOR RAILING TYPE AND INFORMATION, SUBMIT SHOP DRAWINGS OF RAILING DESIGN AND ATTACHMENT FOR REVIEW BALCONY BEAM PER PLAN CANTILEVERED LEDGER BEAM PER PLAN 2" 3 1/2" 2"1 1/2"3 1/2"NOTE: FOR LEDGER ATTACHMENT WITH SIMPSON SCREWS, PROVIDE MINIMUM 1½" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. TYPE IIIA, TRUSSES PARALLEL PROVIDE 2x FRT BLOCKING AT ALL EXTERIOR SHEATHING EDGES 2x NAILER FOR CEILING ATTACHMENT ALTERNATE HEADER LOCATION PER TYPICAL DETAIL SEE ARCH FOR RAILING TYPE AND INFORMATION, SUBMIT SHOP DRAWINGS OF RAILING DESIGN AND ATTACHMENT FOR REVIEW PROVIDE 1/8" MINIMUM GAP AT ALL SHEATHING EDGES SEE ARCH FOR PAD OUT REQUIREMENTS SEE DETAIL 1 ON SHEET S502 FOR ADDITIONAL INFORMATION PROVIDE 2x BLOCKING TO MATCH JOIST DEPTH PLACED AT 45 DEGREES AND ATTACHED TO JOISTS AT EACH END WITH (3) 10d TOENAILS, ATTACH DECK BOARDS FROM ABOVE WITH (2) SCREWS MINIMUM 2x EXTERIOR WALL BEAM, SEE PLAN BEAM, SEE PLANBEAM, SEE PLAN4' - 0" TYP 4' - 0" TYP2x BALCONY JOISTS6 S503 3,4 S503 2 S503A MIN. (3)2x6 WOOD POST AT END BEAM 45° INTERMEDIATE POST ELEVATION END POST ELEVATION SIMPSON LCE4 POST CAP SIMPSON AC6 POST CAP SEE PLAN FOR BEAM AND POST SIZE SEE PLAN FOR BEAM AND POST SIZE INTERMEDIATE POST PLAN VIEW END POST PLAN VIEW STAGGER JOINTS OF BEAM OR PROVIDE MITER JOINT EACH BEAM TO BEAR 50% ON POST PROVIDE 2x6 VERTICAL BLOCK BETWEEN POST AT BEAM LOCATION NOTE: PROVIDE SIMPSON ABU POST BASE TYP. 2x NAILER FOR CEILING ATTACHMENT CANTILEVERED PSL BEAM, EXTEND INTO FLOOR PLENUM AS SHOWN ON PLAN AND TIGHT TO UNDERSIDE OF FLOOR TRUSS TOP CHORDS. TRUSS MANUF TO PROVIDE BEAM POCKET AND DOUBLE TOP CHORDS AT BEAM LOCATION. DESIGN EACH BEAM FOR A 300 POUND UPLIFT FORCE MIN. (2) FLOOR TRUSS VERTICALS SHOWN BEYOND (4)2x6 BUILT-UP POST TIGHT TO UNDERSIDE OF PSL BEAM ALT: HEADER TIGHT TO UNDERSIDE WHERE OCCURS (3)2x10 END BEAM HUNG FROM CANT. BEAMS W/ CONCEALED FLANGE HANGERS DECKING FINISH PER ARCH NOTES: 1. SEE DETAIL 3/S503 FOR INFORMATION NOT SHOWN. 2. FOR LEDGER ATTACHMENT, PROVIDE MINIMUM 1½" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. 2x10 LEDGER WITH (2) ROWS OF SIMPSON SDWS22500DB SCREWS AT 12" O.C. 2x10 JOISTS @ 16" O.C. WITH SIMPSON LUS28 EACH END TRUSSES PARALLEL CANTILEVERED BEAMS TO BE BROUGHT BACK INTO TRUSS SPACE MIN 11'-0", ATTACH TO EACH TRUSS VERTICAL W/ (2)SDWS SCREWS W/ 3" EMBEDMENT SEE ARCH FOR RAILING TYPE AND INFORMATION, SUBMIT SHOP DRAWINGS OF RAILING DESIGN AND ATTACHMENT FOR REVIEW TRUSSES PERPENDICULAR 2x NAILER FOR CEILING ATTACHMENT CANTILEVERED PSL BEAM, EXTEND INTO FLOOR PLENUM AND TIGHT TO UNDERSIDE OF EXTERIOR WALL DOUBLE TOP PLATE. (4)2x6 BUILT-UP POST TIGHT TO UNDERSIDE OF PSL BEAM ALT: HEADER TIGHT TO UNDERSIDE WHERE OCCURS NOTES: 1. SEE DETAIL 4/S503 FOR INFORMATION NOT SHOWN. 2. FOR LEDGER ATTACHMENT, PROVIDE MINIMUM 1½" EDGE DISTANCE, 6" END DISTANCE, AND 4" BETWEEN ROWS. SEE DETAIL 3 ON THIS SHEET FOR ADDITIONAL BALCONY INFORMATION FLOOR TRUSS WEBS SHOWN BEYOND NOTE: HANGER NOT SHOWN FOR CLARITY CANTILEVERED BEAMS TO BE BROUGHT BACK INTO TRUSS SPACE MIN 11'-0", TYP PROVIDE BEAM POCKET FOR (2)2x12 WITHIN FLOOR TRUSS SERIES AT END OF PSL BEAM. ATTACH INTERSECTING BEAM WITH INVERTED 'HU610' FACE MOUNT HANGER. DESIGN EACH TRUSS FOR 300 POUND UPLIFT FORCE DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:39 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS05.13 Author Checker DDS-025-22 WOOD FRAMING AT BALCONIES SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"1 BALCONY BRACING PLAN AT CORNER 3/4" = 1'-0"2 BALCONY BRACING PLAN AT CANTILEVER 3/4" = 1'-0"3 EXTERIOR WALL - WOOD DECKING BALCONY 3/4" = 1'-0"4 EXTERIOR WALL - WOOD DECKING BALCONY 3/4" = 1'-0"5 BALCONY EDGE DETAIL 3/4" = 1'-0"6 BALCONY BRACING PLAN AT INSET 3/4" = 1'-0"7 CANTILEVERED LEDGER BEAM AT BALCONY - TYPE IIIA 3/4" = 1'-0"8 EXTERIOR WALL - JULIET BALCONY DATE DESCRIPTION REV 3/4" = 1'-0"9 BALCONY BRACING PLAN - POST SUPPORTED 3/4" = 1'-0"10 BALCONY POST TO BEAM CONNECTION 3/4" = 1'-0"11 EXTERIOR WALL - CANTILEVERED BALCONY - TYPE IIIA 3/4" = 1'-0"12 EXTERIOR WALL - CANTILEVERED BALCONY - TYPE IIIA TRUSSES PERPENDICULAR 2X4 BLOCKING BETWEEN EACH TRUSS AT SHEATHING EDGES 2x4 BLOCKING BETWEEN TRUSSES AT ALL WALL SHEATHING PANEL EDGES 2x4 DOUBLE TOP PLATE, SPLICE 4'-0" MIN. SIMPSON H2.5T AT EACH TRUSS BEARING POINT PARAPET TO BE A CONTINUATION OF TRUSS END VERTICAL MEMBER, TYP. 2x4 RIBBON WITH (2) 12d NAILS AT EACH TRUSS 2x8 TOP PLATE WITH (1) ROW 12d NAILS AT 3" O.C. EACH SIDE NAIL SHEATHING TO RIBBON WITH 8d NAILS AT 6" O.C. SIMPSON H2.5T AT EACH TRUSS BEARING POINT SIMPSON A35 CLIP AT 24" O.C. MAX. CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICAL AND TOP/BOTTOM RIBBON WITH 8d NAILS SPACED AT 4" O.C. ALONG ALL EDGES 2x4 RIBBON WITH (2) 12d NAILS AT EACH TRUSS 2x8 TOP PLATE WITH (1) ROW 12d NAILS AT 3" O.C. EACH SIDE NAIL SHEATHING TO RIBBON WITH 8d NAILS AT 6" O.C. SIMPSON H2.5T AT EACH TRUSS BEARING POINT CONTINUOUS 2x6 NAILER ATTACHED TO TOP PLATE WITH 12d NAILS AT 6" O.C. CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICAL AND TOP/BOTTOM RIBBON WITH 8d NAILS SPACED AT 6" O.C. ALONG ALL EDGES ATTACH 2x4 RIBBON TO NAILER WITH 12d NAILS AT 6" O.C. TRUSSES PARALLEL 2x8 TOP PLATE WITH (1) ROW 12d NAILS AT 3" O.C. EACH SIDE NAIL SHEATHING TO TRUSS WITH 8d NAILS AT 6" O.C. CONTINUOUS 2x6 NAILER ATTACHED TO TOP PLATE WITH 12d NAILS AT 6" O.C. CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICALS AND TOP/BOTTOM CHORD WITH 8d NAILS SPACED AT 6" O.C. ALONG ALL EDGES ATTACH TRUSS BOTTOM CHORD TO NAILER WITH 12d NAILS AT 6" O.C. DOUBLE 2x8 P.T. PLATES ATTACHED TO CMU WITH 1/2"x9" SIMPSON TITEN HD SCREW ANCHOR WITH 3"x3" BEARING PLATE AT 24" O.C. 8" BOND BEAM, SEE MASONRY NOTES FOR ADDITIONAL INFORMATION 2x10 JOISTS AT 16" O.C. DOUBLE JOIST AT EDGE OF SHAFT ELEVATOR HOIST BEAM AS NOTED AND ORIENTED ON PLAN WITH 4"x6"x1/4" BEARING PLATE WITH 1/2"x6" LONG HEADED STUD DOUBLE 2x8 P.T. PLATES ATTACHED TO CMU WITH 1/2"x9" SIMPSON TITEN HD SCREW ANCHOR WITH 3"x3" BEARING PLATE AT 24" O.C. 8" BOND BEAM, SEE MASONRY NOTES FOR ADDITIONAL INFORMATION 2x10 JOISTS AT 16" O.C. SIMPSON H2.5T EACH END OF JOIST, TYP. 2x10 RIM JOIST WITH (4) 12d END NAILS INTO EACH JOIST PREFAB ROOF TRUSSES 2x8 STUDS AT 24" O.C. W/ SINGLE BASE AND DOUBLE TOP PLATES. SHEATH EACH SIDE WITH 3/4" P.T. PLYWOOD ATTACHED W/ 8d NAILS AT 4" O.C. AT EDGE AND 12" O.C. IN FIELD ATTACH BASE PLATE TO EACH TRUSS W/ (2) ROWS SIMPSON 'SDS25500' SCREWS. LOCATE 1.5" FROM SIDE OF PLATE 4'-0" MAX.2X4 BLOCKING BETWEEN EACH TRUSS AT SHEATHING EDGES 2x4 BLOCKING BETWEEN TRUSSES AT ALL WALL SHEATHING PANEL EDGES 2x4 DOUBLE TOP PLATE, SPLICE 4'-0" MIN. SIMPSON H2.5T AT EACH TRUSS BEARING POINT DOUBLE 2x8 P.T. PLATES ATTACHED TO CMU WITH 1/2"x9" SIMPSON TITEN HD SCREW ANCHOR WITH 3"x3" BEARING PLATE AT 24" O.C. 8" BOND BEAM, SEE MASONRY NOTES FOR ADDITIONAL INFORMATION 2x4 RIBBON WITH (2) 12d NAILS AT EACH TRUSS NAIL SHEATHING TO RIBBON WITH 8d NAILS AT 6" O.C. SIMPSON H2.5T AT EACH TRUSS BEARING POINT CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICAL AND TOP/BOTTOM RIBBON WITH 8d NAILS SPACED AT 6" O.C. ALONG ALL EDGES SIMPSON A35 CLIP AT 24" O.C. MAX. 8" CMU WALL, SEE MASONRY NOTES FOR ADDITIONAL INFORMATION 8" BOND BEAM W/ (1)#5 BAR CONT. RATED CEILING PER ARCH 2x4 RIBBON WITH (2) 12d NAILS AT EACH TRUSS NAIL SHEATHING TO RIBBON WITH 8d NAILS AT 6" O.C. CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICAL AND TOP/BOTTOM RIBBON WITH 8d NAILS SPACED AT 6" O.C. ALONG ALL EDGES SIMPSON A35 CLIP AT 24" O.C. MAX. 8" CMU WALL, SEE MASONRY NOTES FOR ADDITIONAL INFORMATION 8" BOND BEAM W/ (1)#5 BAR CONT. RATED CEILING PER ARCH TRUSSES PARALLEL PROVIDE TRUSS OVER WALL 2x4 BLOCKING BETWEEN STUDS AT ALL WALL SHEATHING PANEL EDGES 2x4 DOUBLE TOP PLATE, SPLICE 4'-0" MIN. 2x4 LADDER TRUSS WITH (2)2x4 VERTICALS AT 16" O.C. 2x4 BRACING ATTACHED TO LADDER TRUSS AT 4'-0" O.C. MAX. WITH (5) 12d NAILS 2x4 BLOCK ATTACHED TO TRUSS TOP AND BOTTOM CHORD WITH (4) 12d NAILS ATTACH BRACING TO BLOCK WITH (2) 12d NAILS 2x4 DIAGONAL ACROSS TOP AND BOTTOM BRACE ATTACHED WITH (4) 12d NAILS EACH NOTE: COORDINATE PARAPET HEIGHT W/ ARCH SECTIONS AND ELEVATIONS TRUSSES PERPENDICULAR 8" CMU WALL, SEE MASONRY NOTES FOR ADDITIONAL INFORMATION PROVIDE (3) 12d TOENAILS FOR TRUSS TO TOP PLATE CONNECTION 2x4 RIBBON WITH (2) 12d NAILS AT EACH TRUSS NAIL SHEATHING TO RIBBON WITH 8d NAILS AT 6" O.C. SIMPSON H2.5T AT EACH TRUSS BEARING POINT TRUSSES PARALLEL 8" CMU WALL, SEE MASONRY NOTES FOR ADDITIONAL INFORMATION NAIL SHEATHING TO TRUSS TOP CHORD WITH 8d NAILS AT 6" O.C. CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICALS AND TOP/BOTTOM CHORD WITH 8d NAILS SPACED AT 6" O.C. ALONG ALL EDGES 2x4 RIBBON WITH (2) 12d NAILS AT EACH TRUSS NAIL SHEATHING TO RIBBON WITH 8d NAILS AT 6" O.C. SIMPSON H2.5T AT EACH TRUSS BEARING POINT SIMPSON A35 CLIP AT 24" O.C. MAX. CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICAL AND TOP/BOTTOM RIBBON WITH 8d NAILS SPACED AT 6" O.C. ALONG ALL EDGES ATTACH 2x4 RIBBON TO NAILER WITH 12d NAILS AT 6" O.C. 2x4 RIBBON WITH (2) 12d NAILS AT EACH TRUSS NAIL SHEATHING TO RIBBON WITH 8d NAILS AT 6" O.C. SIMPSON H2.5T AT EACH TRUSS BEARING POINT CONTINUOUS 2x4 NAILER ATTACHED TO TOP PLATE WITH 12d NAILS AT 6" O.C. CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICAL AND TOP/BOTTOM RIBBON WITH 8d NAILS SPACED AT 6" O.C. ALONG ALL EDGES ATTACH 2x4 RIBBON TO NAILER WITH 12d NAILS AT 6" O.C. NAIL SHEATHING TO TRUSS WITH 8d NAILS AT 6" O.C. SIMPSON A35 CLIP AT 24" O.C. MAX CONTINUOUS 7/16" DRAFT STOPPING NAILED TO TRUSS VERTICALS AND TOP/BOTTOM CHORD WITH 8d NAILS SPACED AT 6" O.C. ALONG ALL EDGES TRUSSES PARALLEL NAIL SHEATHING TO TRUSS WITH 8d NAILS AT 6" O.C. TOE NAIL TRUSS TO TOP PLATES WITH 12d NAILS SPACED AT 6" O.C. HEADER, PER PLAN TRUSSES PERPENDICULAR 2X4 BLOCKING BETWEEN EACH TRUSS AT SHEATHING EDGES 2x4 BLOCKING BETWEEN TRUSSES AT ALL WALL SHEATHING PANEL EDGES 2x6 DOUBLE TOP PLATE, SPLICE 4'-0" MIN. SIMPSON H2.5T AT EACH TRUSS BEARING POINT PARAPET TO BE A CONTINUATION OF TRUSS END VERTICAL MEMBER. PROVIDE 45 DEGREE KICKERS AS NEEDED PLACE BEAM ATOP WALL PLATES AS NEEDED FOR DEPTH REQUIREMENTS. PROVIDE MID- CHORD BEARING ROOF TRUSS NOTE: COORDINATE PARAPET HEIGHT W/ ARCH SECTIONS AND ELEVATIONS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 11/28/2022 2:10:40 PM D:\724 Consulting Dropbox\724 Consulting Team Folder\PROJECTS\DDS-025-22 Mill Creek Foundry\%Structural%\DDS-025-22_Foundry_R22.rvtS05.21 MG,GK,MS MJS DDS-025-22 ROOF FRAMING DETAILS SCHEMATIC DESIGN PACKAGE 11/04/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALFOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NC3/4" = 1'-0"1 ROOF EXTERIOR WALL - TRUSSES PERPENDICULAR 3/4" = 1'-0"3 ROOF UNIT SEPARATION WALL - BOTH SIDES BEARING 3/4" = 1'-0"4 ROOF UNIT SEPARATION WALL - ONE SIDE BEARING 3/4" = 1'-0"5 ROOF UNIT SEPARATION WALL - TRUSSES PARALLEL 3/4" = 1'-0"9 ROOF ELEVATOR SHAFT - 2X FRAMING PARALLEL 3/4" = 1'-0"8 ROOF ELEVATOR SHAFT - 2X FRAMING PERPENDICULAR 3/4" = 1'-0"14 ROOF MECHANICAL WALL (AS NEEDED FOR PIPING) 3/4" = 1'-0"16 ROOF EXTERIOR WALL - CMU BEARING 3/4" = 1'-0"17 ROOF CMU BEARING WALL - PERPENDICULAR 3/4" = 1'-0"18 ROOF CMU BEARING WALL - PARALLEL 3/4" = 1'-0"2 ROOF EXTERIOR WALL - TRUSSES PARALLEL 3/4" = 1'-0"6 ROOF CMU SHAFT - TRUSSES PERPENDICULAR 3/4" = 1'-0"7 ROOF CMU SHAFT - TRUSSES PARALLEL 3/4" = 1'-0"10 ROOF CORRIDOR BEARING WALL - SHARED BEARING 3/4" = 1'-0"11 ROOF CORRIDOR BEARING WALL - ONE SIDE BEARING 3/4" = 1'-0"12 ROOF FIREWALL AT UNIT SEPARATION 3/4" = 1'-0"13 ROOF FIREWALL AT CORRIDOR 3/4" = 1'-0"15 ROOF EXTERIOR WALL - TRUSSES PERPENDICULAR DATE DESCRIPTION REV PUMP SCHEDULE FIRE PROTECTION LEGEND F T F SCALE:1 NTS SCALE: N.T.S.4 TEST AND DRAIN VALVE VIKING MODEL A-1, AGF MODEL 1000, OR APPROVED EQUAL7'-0" MAX SIGHT GLASS STANDPIPE OR SPRINKLER RISER MINIMUM 2" SPRINKLER TEST/DRAIN TO FLOOR SPRINKLER SYSTEM BY SPRINKLER CONTRACTOR FT NOTES: 1. COORDINATE WATER FLOW AND VALVE SUPERVISORY SWITCH CONNECTIONS WITH FIRE ALARM CONTRACTOR. 2. INSTALL TEST AND DRAIN ASSEMBLY IN ACCORDANCE WITH MANUFACTURERS REQUIREMENTS. 3. SEE FLOOR PLANS FOR LOCATION OF STANDPIPE/SPRINKLER RISER. FLOOR SPRINKLER CONTROL VALVE FDV 2 1/2" FIRE DEPARTMENT VALVE MAIN LANDING (SEE PLANS) MAIN LANDING FT FLOW AND TAMPER SWITCH FOR EACH FIRE/SPRINKLER RISER PRESSURE REDUCING VALVE, REFER TO FIRE PROTECTION NOTES FOR ADDITIONAL INFORMATION. (TYP.) PRV PRV 4. FDC WILL HAVE ONE 2.5" HOSE CONNECTION PER 250 GPM OF STANDPIPE DEMAND. SCALE:2 NTS MAIN DRAIN FIN. FL. ALARM BELL ELECTRIC TO SPRINKLER SYSTEM FLOW SWITCH 1" FLOW TEST LINE TEST CONNECTION SPARE CABINET SPRINKLER NFPA-13 PER MAIN DRAIN VALVE SUPPLY WATER GAUGE AND VALVE RISER CHECK VALVE GAUGE AND VALVE SYSTEM WATER SCALE: BUTTERFLY VALVE WITH TAMPER SWITCH TAMPER SWITCH CHECK VALVE TEST DRAIN VALVE MAINTENANCE DEVICE AIR PRESSURE ACCELERATOR ALARM VALVE VALVE WITHINDICATOR DRAIN CUP VALVE ALARM TEST DRY PIPE AIR COMPRESSOR RISER MOUNTED SUBJECT TO FREEZING TO SERVE ALL SPACES THRUST BLOCK NOTE: ALL SYSTEM GAUGES AND VALVES MUST BE ACCESSIBLE FOR INSPECTION AND MAINTENANCE. THREADED ROD JOINT RESTRAINT WALL MOUNTED FDC, SEE DRAWINGS FOR LOCATION 3 NTS WATTS LF880V OS&Y BACKFLOW PREVENTER BY PASS BY PASS 10" DRAIN 10" DRAIN 8" REDUCED PRINCIPLE BACKFLOW PREVENTION ASSEMBLY INSTALLED PER CLTWATER REQUIREMENTS. LOCATION TO INCLUDE DRAINAGE FOR DISCHARGE WATER PER CLTWATER REQUIREMENTS. FIRE PUMP LICENSED IN THE STATE OF NORTH CAROLINA OR EQUIVALENT FIRE SPRINKLER SYMBOL SERVICE/LOCATION TYPE FLOW (GPM) HEAD (PSI)RPM HP NOTES FP-1 FIRE/ PUMP ROOM HORIZONTAL SPLIT CASE 1000 --- 3550 --- 1,3,4 JP-1 FIRE/ PUMP ROOM CENTRIFUGAL 10 90 --- -2,4 NOTES: 1. BASIS OF DESIGN: - CONTROL PANEL: REDUCED VOLTAGE, ELECTRONIC, SOFT START (25% OF FULL VOLTAGE AT STARTING) 2. BASIS OF DESIGN: GOULDS MODEL 3SV WITH FIRETROL FTA 550 JOCKEY PUMP CONTROL PANEL. 3. FIRE PUMP SHALL COMPLY WITH NFPA 20 AND SHALL MEET 150% MAXIMUM CAPACITY PERFORMANCE. 4. ALL THREE-PHASE PUMP MOTORS 1 HP OR LARGER SHALL MEET OR EXCEED EFFICIENCY STANDARDS FOR NEMA PREMIUM MOTORS. FLOW TEST DATA SCHEDULE LOCATION OF TEST HYDRANT DATE OF TEST TIME OF DAY OF TEST STATIC PRESSURE RESIDUAL PRESSURE FLOW (GPM) UPON AWARD OF THE CONTRACT, THE FIRE PROTECTION CONTRACTOR SHALL PERFORM A FLOW TEST ON THE TWO HYDRANTS NEAREST THE SITE AND FORWARD THE TEST DATA TO THE ENGINEER AND ARCHITECT. THE FOLLOWING WATER PRESSURE/FLOW DATA WAS OBTAINED FROM: CHARLOTTE FIRE DEPARTMENT 48 HOUR HIGH PRESSURE 48 HOUR LOW PRESSURE 48 HOUR AVERAGE PRESSURE HYDRANT NUMBER TYPE/OWNER PRESSURE CALCULATIONS: FIRE PUMP PRESSURE ---- PSI X CHURN PRESSURE 1.4 = --- PSI ---- PSI + (48 HOUR HIGH) 60 PSI = ---- PSI BASED ON CURRENT PRESSURE FLOW FROM THE FIRE PUMP, PRV WILL BE REQUIRED AT EACH LEVEL. FIRE SPRINKLER CONTRACTOR TO CONFIRM CALCULATION REQUIREMENTS. BUILDING CALCULATIONS BUILDING = --- PSI - ----- PSI LOSS = ----- PSI AT THE TOP LEVEL OF THE STAND PIPE. PSI PSI GPM --- --- --- ------- ----- ---- PSI PSI --- --- PSI--- ---- PUBLIC BPA-2 FIRE PROTECTION SYSTEM MATERIALS 14. 13. 8. 12. 11. 10. 7. 5. 4. 2. 1. 3. 6. 9. 15. ALL FIRE PROTECTION DRAWINGS SUBMITTALS SHALL BE AT 1/8" SCALE AS A MINIMUM. SUBMITTALS OF MULTIPLE PRINTS WILL BE RETURNED WITHOUT REVIEW. ALL SPRINKLER PIPING SHALL BE ROUTED TO MAINTAIN DESIGNED CEILING HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG FROM THE TOP CHORDS OF THE JOISTS. ALL FIRE PROTECTION EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. SPRINKLER HEADS INSTALLED IN LAY IN ACOUSTICAL TILE CEILINGS SHALL BE CENTERED IN THE CEILING TILES OR INSTALLED ON QUARTER POINTS OF THE FOUR FOOT DIMENSIONS OF 2'X4' TILES ALL PIPE, SUPPORTS AND HANGER ASSEMBLIES SHALL BE IN ACCORDANCE WITH NFPA-13 AND SHALL BE U.L. LISTED OR F.M. APPROVED. ALL INTERIOR SPRINKLER PIPING SHALL MEET THE REQUIREMENTS OF APPLICABLE SECTIONS OF NFPA, AND THE OWNER'S UNDERWRITER. ALL PIPE, FITTINGS, VALVES, AND SPRINKLER SYSTEM COMPONENTS SHALL BE RATED FOR WORKING PRESSURES AS REQUIRED BY SYSTEM DESIGN. D. ALTERNATE ACCEPTABLE MANUFACTURERS WITH EQUIVALENT SPRINKLERS ARE TYCO, AND RELIABLE. C. FAST RESPONSE UPRIGHT PENDENT SPRINKLERS SHALL BE PROVIDED IN ALL AREAS WITH NO CEILING. TEMPERATURE RATING IS TO BE 165° UNLESS CONDITIONS REQUIRE HIGHER TEMPERATURE. FINISH OF SPRINKLER TO BE ROUGH BRASS. SPRINKLER TO BE VIKING MICROFAST MODEL M. B. RESIDENTIAL SEMI-RECESSED SPRINKLERS SHALL BE USED IN RESIDENTIAL UNITS. A. SMALL FRAME GLASS ELEMENT, SEMI-RECESSED, FAST RESPONSE PENDENT SPRINKLERS SHALL BE PROVIDED IN ALL REMAINING AREAS WITH LAY-IN OR HARD CEILINGS UNLESS OTHERWISE NOTED. AUTOMATIC SPRINKLERS SHALL BE PROVIDED AS FOLLOWS: B. LIGHTWALL, 150 PSI, BUTTWELD FITTINGS, ANSI B16.9. A. GROOVED MECHANICAL COUPLINGS AND FITTINGS WITH EPDM GASKET, MALLEABLE IRON OR DUCTILE IRON, 800 PSI MINIMUM RATING ASTM A47, AND A536, U.L. LISTED, F.M. APPROVED. LIGHTWALL WELDED OR SEAMLESS STEEL PIPE, ASTM A53, AND A135. C. CPVC PIPING IS NOT TO BE INSTALLED IN AREAS OF EXPOSED CONSTRUCTION. PROVIDE STEEL PIPE AND FITTINGS IN ALL AREAS WHERE PIPING IS EXPOSED. B. SCHEDULE 80 CHLORINATED POLYVINYL CHLORIDE (CPVC), THREADED, ASTM F437, UL LISTED, PLENUM RATED. A. SCHEDULE 80 CHLORINATED POLYVINYL CHLORIDE (CPVC), SOLVENT WELDED SOCKET, ASTM F439, UL LISTED, PLENUM CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE, ASTM D1784 AND F442, UL LISTED, PLENUM RATED B. CLASS 150, AND 300 MALLEABLE IRON THREADED FITTINGS, ANSI B16.3. C. GROOVED MECHANICAL COUPLINGS AND FITTINGS WITH EPDM GASKET, MALLEABLE IRON OR DUCTILE IRON, 800 PSI MINIMUM RATING ASTM A47 AND A536, U.L. LISTED, F.M. APPROVED. A. CLASS 125, AND 250 CAST IRON THREADED FITTINGS, ANSI B16.4. SCHEDULE 40 WELDED OR SEAMLESS STEEL PIPE, ASTM A53, AND A135. FIRE PROTECTION SHOP DRAWINGS SHALL INCLUDE ALL DATA REQUIRED BY NFPA 13 SHOP DRAWING PLANS SHALL INDICATE ALL LIGHTS, GRILLES, SOFFITS, ALARMS, SPEAKERS AND OTHER CEILING COMPONENTS, AS WELL AS HYDRAULIC NODE POINTS, TO INSURE COORDINATION. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS TO AND SECURE APPROVAL OF THE OWNER'S UNDERWRITER, LOCAL AUTHORITY AND OR STATE AUTHORITIES PRIOR TO SUBMISSION TO THE ENGINEER. THE CONTRACTOR SHALL NOT COMMENCE WORK, PURCHASE, OR PROVIDE ANY MATERIALS TO THE JOB SITE WITHOUT OBTAINING SHOP DRAWING APPROVAL FROM THE ABOVE AND THE ENGINEER. SHOP DRAWINGS SHALL INCLUDE COPIES OF ALL HYDRAULIC CALCS PROVIDING DESIGN DENSITIES, WHERE APPLICABLE. ALL DESIGN DRAWINGS AND CALCULATIONS PREPARED BY THE FIRE PROTECTION SUBCONTRACTOR SHALL BEAR THE SEAL OF A REGISTERED PROFESSIONAL ENGINEER CONTRACTOR'S CERTIFICATE SEAL. CONTRACTOR TO ENSURE ALL FUSEABLE LINKS, FIRE SPRINKLER HEADS, OR OTHER ITEMS PROHIBITED FROM RECEIVING PAINT ARE NOT PAINTED AND ARE NOT COATED WITH RESIDUAL OR MISTING PAINT. ALL MATERIALS, PIPE, VALVES AND EQUIPMENT FURNISHED UNDER THIS SECTION SHALL BE NEW AND APPROVED BY NFPA, UNDERWRITER'S LABORATORIES, INC. (U.L.), FACTORY MUTUAL(F/M) AND AMERICAN WATER WORKS ASSOCIATION (AWWA) WHERE APPLICABLE. LIGHT .10 1500 SQ. FT. 225 SQ. FT. 100 GPM ORDINARY .15 1500 SQ. FT. 130 SQ. FT. 250 GPM GROUP 1 PUBLIC SPACES, LOBBIES,CORRIDORS, OFFICES, RESTAURANTS, LOUNGES, MEETING ROOMS, DWELLING UNITS, BALCONIES MECHANICAL ROOMS, ELECTRICAL/TELECOM ROOMS, A/V CLOSETS ELEVATOR EQUIPMENT ROOMS, MAINTENANCE/STORAGE ROOMS, KITCHEN/FOOD SERVICE AREAS, LAUNDRY POOL EQUIPMENT ROOMS HAZARD CLASSIFICATIONAREA/USAGE DENSITY GPM/SQ.FT. DEVICE TEMPERATURE RATING REMOTE AREA MAXIMUM HEAD SPACING INTERIOR HOSE STREAM 165° F 165° F DESIGN CRITERIA SPRINKLER, EXTENDED COVERAGE HORIZONTAL SIDEWALL ABBREVIATIONSYMBOL SPRINKLER, PENDENT SPRINKLER SYSTEM PIPING VALVE SUPERVISORY SWITCH FIRE STANDPIPE W/2-1/2" FIRE DEPARTMENT HOSE VALVE FIRE DEPARTMENT HOSE VALVE CABINET VALVE, CHECK WATER FLOW SWITCH, VANE TYPE FIRE DEPARTMENT HOSE VALVE, PLAN/RISER CV TSW SSP SWE SP FDV FSV FVC FSP FIRE PROTECTION SUPPLY PIPINGF DESCRIPTION PG PRESSURE GAUGE SPRINKLER, PENDENT ON DROPSSPD SPRINKLER, HORIZONTAL SIDEWALLSW SPRINKLER, UPRIGHT ON 1" SPRIG-UP SPRINKLER, UPRIGHT SSUS SSU WATER FLOW SWITCH, PRESSURE TYPEFSP BFV VALVE, BUTTERFLY, PLAN/VERTICAL OSY VALVE, OS&Y GATE, IN-LINE/VERTICAL VALVE, GENERAL, OS&Y GATE OR BUTTERFLYGV ACV VALVE/RISER, ALARM CHECK DPV VALVE/RISER, DRY PIPE SPRINKLER DLV VALVE/RISER, DELUGE SPRINKLER PAV VALVE/RISER, PRE-ACTION SPRINKLER FIRE DEPARTMENT SIAMESE CONNECTION, FREE STANDINGFDCF FIRE DEPARTMENT SIAMESE CONNECTION, WALL MOUNTEDFDCW BFP VALVE, DOUBLE CHECK BACKFLOW PREVENTER WMG WATER MOTOR GONG PMP PUMP EB ELECTRIC BELL THF FIRE PUMP TEST HEADER, FREE STANDING FLOOR CONTROL VALVE ASSEMBLY, SPRINKLER SYSTEMFCV DELUGE SPRINKLER SYSTEMDL DRY PIPE SPRINKLER SYSTEMDP PA PRE-ACTION SPRINKLER SYSTEM THW FIRE PUMP TEST HEADER, WALL MOUNTED FIRE DEPARTMENT SIAMESE CONNECTION, RECESS MOUNTEDFDCR SPRINKLER, EARLY SUPPRESSION FAST RESPONSEESFR PIPE UP, TEE DOWN, ELBOW DOWN WP WET PIPE SPRINKLER SYSTEM VALVE, ANGLED, PLAN/RISERAV T F AIR PRESSURE SWITCH, HIGH AND LOW ALARMASPA SPRINKLER, PENDENT, CONCEALEDSSPC THR FIRE PUMP TEST HEADER, RECESS MOUNTED SP POC POINT OF CONNECTION TO EXISTING DRY CONTACT FOR FIRPUMP OR OTHER CONTROLLERDCD DP DL PA WP ESFR EARLY SUPPRESSION, FAST RESPONSE F FIRE PROTECTION CONTRACTOR SHALL CONFIRM WITH ELECTRICAL CONTRACTOR THE REQUIRED SCCR RATINGS FOR ALL EQUIPMENT. NO EQUIPMENT SHALL BE ORDERED PRIOR TO CONFIRMATION OF SCCR VALUES. 16. .15 1950 SQ. FT. 130 SQ. FT. 250 GPM DRY PIPE SYSTEMS: PARKING GARAGES, NON-HEATED ATTIC SPACES, CEILING SPACES, PORTE COCHERE AND OTHER SPACES CONTAINING SPRINKLER PIPING THAT DO NOT HAVE ALTERNATE PROVISIONS TO GUARANTEE A 40 DEGREE F. TEMPERATURE 165° F ORDINARY GROUP 1 ORDINARY .20 1500 SQ. FT. 130 SQ. FT. 250 GPM GROUP 2 BALLROOMS, EXTERIOR LOADING DOCKS (SEE NFPA 13-A5.3.2) 165° F FIRE PROTECTION DESCRIPTION OF WORK 1. PROVIDE SPRINKLER COVERAGE FOR ENTIRE BUILDING IN ACCORDANCE WITH NFPA 13, 2013 EDITION. 2. PROVIDE AUTOMATIC STANDPIPES IN EXIT STAIRS PER NFPA 14, 2013 EDITION. 3. IN PUBLIC AREAS WITH CEILING, PROVIDE CONCEALED HEADS WITH COVER TO MATCH ADJACENT FINISH. 4. PROVIDE SEMI-RECESSED HEADS IN UNITS. 5. PROVIDE FLOOR CONTROL VALVES ON EACH LEVEL FOR WET SYSTEM. PROVIDE SEPARATE FLOOR CONTROL VALVE FOR EACH AREA SEPARATED FROM ANOTHER AREA BY FIREWALL. 6. PROVIDE DRY PIPE SYSTEM FOR PARKING GARAGE AND ALL OTHER UNHEATED AREAS IN RISER ROOM. FIRE SERVICE DETAIL W/ FLOOR CONTROL ASSEMBLY DRY PIPE VALVE ASSEMBLY RISER DETAIL GASKET MATERIAL AND CONCRETE THRUST RTV CAULKING. SEAL WITH DOW#780 #4 DEF. BARS CONT. & VERT. 8" O.C. 2'-0" 3'-0" CAULK WITH NEOPRENE SCHEDULE 40 GALV. SLEEVE FLANGED FITTING FIN. FLOOR 8" INTERIOR PIPING AS SPECIFIED 12" MIN. FITTING FLANGED UNDERGROUND SPECIFIED. PIPING AS MIN EXTERIOR WALL PIPING UNDER BUILDING AS SHOWN ON DRAWINGS BUILDING TO BE ROUTED AND TO A POINT OUTSIDE FINISHED GRADE 12" ADAPTER AS REQUIRED SPRINKLER SYSTEM ENTRY DETAIL RPZ (REDUCED PRESSURE ZONE ASSEMBLY) VERTICAL 8" 1-5 SYMBOL FIRE PROTECTION BACKFLOW PREVENTER SCHEDULE MODEL TYPE SERVICE SIZE NOTES FIRE SPRINKLER SUPPLY FEBCO LF880V OS&Y FIRE SERVICE ENTRANCE DETAIL (W/ BPA-2) NOTES: 1. ASSEMBLY SHALL BE INSTALLED PER ALL PERTINENT STATE, NFPA AND LOCAL JURSIDICTION REQUIREMENTS. 2. PROVIDE AIR GAP AND PIPE DISCHARGE INDIRECTLY TO FLOOR DRAIN, HUB DRAIN, OR THROUGH EXTERIOR WALL TO ATMOSPHERE. 3. THERE SHALL BE NO TAPS, PIPING BRANCHES, UN-APPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. CONNECTION POINTS, OR OTHER WATER USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND CHARLOTTE WATER REQUIRED BACKFLOW PREVENTER. 4. EACH CHARLOTTE WATER REQUIRED BACKFLOW PREVENTER IS REQUIRED TO BE TESTED BY A CHARLOTTE WATER APPROVED CERTIFIED TESTER PRIOR TO PLACING THE WATER SYSTEM IN SERVICE. 5. INSTALLATION INSIDE BUILDING: CLEARANCES SHALL BE 30" FROM WALL OR ANY OBSTRUCTION ON THE SIDE UTILIZED FOR TESTING AND 12" FROM OTHER SIDE. FIRE PROTECTION NOTES 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 1. SPRINKLER DESIGN CRITERIA SHALL BE PER NFPA 13.15. HOSE CONNECTIONS SHALL BE LOCATED WITHIN 5'-0" OF STAIRWELL DOOR.16. FIELD ADJUSTABLE PRESSURE REDUCING VALVE FOR HOSE CONNECTION IN STAIRWELL SHALL BE REQUIRED AT ALL LEVELS. 17. PROVIDE PRESSURE REDUCING VALVE AT EACH FLOOR LEVEL WHERE THE TOTAL ADDED PRESSURES OF THE 48 HOUR HIGH PRESSURE TEST, CHURN PRESSURE OF THE PUMP AND THE OPERATING PRESSURE OF THE PUMP EXCEED 175 PSI. 18. SPRINKLER HEADS LOCATED IN COOLERS AND FREEZERS SHALL BE QUICK RESPONSE, SEMI-RECESSED CHROME PLATED DRY PENDENT SPRINKLERS WITH SPRINKLER GUARDS. BARREL LENGTH SHALL BE MINIMUM 12" FROM THE BASE OF THE TEE TO THE TOP OF THE FREEZER. SPRINKLER AND ESCUTCHEON SHALL BE POLISHED CHROME FINISH. SPRINKLER SHALL BE VIKING MODEL M OR EQUAL. 19. ALL SPRINKLERS IN SPACES VISIBLE TO PUBLIC VIEW SHALL BE LOCATED SYMMETRICALLY IN RELATION TO CEILING DESIGN ELEMENTS, LIGHTING FIXTURES, SPEAKERS, DIFFUSERS, ETC. ALL CEILING COMPONENTS ARE TO BE INDICATED ON THE SUBMITTAL DRAWINGS AS PIPING TO SPRINKLERS IN THESE AREAS IS TO BE PROVIDED WITH RETURN BENDS IF REQUIRED TO ALLOW FOR EXACT PLACEMENT. SPRINKLER HEADS INSTALLED IN LAY IN ACOUSTICAL TILE CEILINGS SHALL BE CENTERED IN THE CEILING TILES OR INSTALLED ON QUARTER POINTS OF THE FOUR FOOT DIMENSIONS OF 2'X4' TILES. ALL FIRE PROTECTION WORK SHALL COMPLY WITH ALL APPLICABLE SECTIONS OF NFPA STANDARDS AND SHALL MEET THE APPROVAL OF THE OWNERS INSURANCE UNDERWRITER, AND LOCAL AUTHORITIES HAVING JURISDICTION. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT PRIOR TO ORDERING, PURCHASING, OR FABRICATION ANY FIRE PROTECTION EQUIPMENT. SHOP DRAWINS SHALL INCLUDE: SPRINKLER DRAWINGS AND CALCS BEARING THE SEAL OF A REGISTERED PROFESSIONAL ENGINEER OR EQUIVALENT CONTRACTORS FIRE SPRINKLER CERTIFICATE SEAL AND APPROVAL STAMP OF LOCAL CODE AUTHORITY; SPRINKLER PIPING; SPRINKLER HEADS; HOSE RACKS, HYDRANTS AND VALVES; PUMPS, CONTROLLERS AND ACCESSORIES; TANKS AND ACCESSORIES. SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE OWNERS INSURANCE UNDERWRITER PRIOR TO BEING SUBMITTED TO THE ARCHITECT. CONTRACTOR SHALL COORDINATE THE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL FIRE PROTECTION EQUIPMENT WITH ELECTRICAL DRAWINGS AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. ALL FIRE PROTECTION EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG FROM THE TOP CHORDS OF THE JOISTS. ALL SPRINKLER SYSTEMS SHALL BE DESIGNED TO THE AVAILABLE CITY WATER SUPPLY. CONTRACTOR SHALL HAVE CURRENT FLOW TEST PERFORMED PRIOR TO DESIGN. ALL SPRINKLER SYSTEM RISERS SHALL INCLUDE AN ALARM CHECK VALVE, WATER MOTOR GONG, FLOW SWITCH, ETC. HYDRAULIC CALCULATIONS SHALL INCLUDE AN ALLOWANCE FOR INSIDE AND OUTSIDE HOSE STREAMS. FIRE PROTECTION SUBCONTRACTOR SHALL FURNISH AND INSTALL 2A RATED 10 LB. FIRE EXTINGUISHERS FOR EVERY 3000 SQ.FT. OF FLOOR AREA. EXTINGUISHERS SHALL BE LOCATED TO MINIMIZE TRAVEL DISTANCE TO 75 FEET. ALL MAJOR VALVES SHALL HAVE U.L. LISTED SUPERVISORY SWITCHES COMPATIBLE WITH THE OWNERS CENTRAL ALARM SYSTEM. WIRING OF THE SWITCHES SHALL BE BY OTHERS. GROOVED (VICTAULIC) COUPLINGS SHALL NOT BE USED OVER OR NEAR ELECTRICAL SWITCHGEAR, PANELS, TRANSFORMERS, ETC. ALL SPRINKLER PIPING SHALL BE ROUTED TO MAINTAIN MINIMUM CLEAR HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. SPECIFICATIONS FOR PIPE MATERIALS REQUIREMENTS O.S.&Y. GATE NFPA REQUIREMENTS VALVE ASSEMBLY PER RATED DOUBLE CHECK FULL PIPE SIZE UL/FM FURNISH AND INSTALL WATER SUPPLY ENTRANCE, TAMPER SWITCH VALVE WITH PER NFPA AND VALVE PROVIDE AND INSTALL MAIN PRESSURE SWITCH ADAPTORS, DEVICES ASSEMBLY, COMPLETE AND ACCESSORIES WITH NECESSARY SYSTEM. REFER TO PLANS AND SPRINKLER AND/OR STANDPIPE EXTEND TO AUTOMATIC DRY-PIPE UL/FM RATED UL/FM RATED DRY PIPE/CHECK VALVE AND REQUIRED SIZES MANUFACTURERS MAIN DRAIN PIPE, EXTEND TO EXTERIOR OF BUILDING OR NEAREST DRAIN (IF REQUIRED) MAIN DRAIN VALVE ALARM TEST VALVE TAMPER SWITCH UL/FM RATED AIR PRESSURE ACCELERATOR OR ELECTRIC ALARM BELL TO WATER MOTOR GONG MAINTENANCE DEVICE ACTUATOR DRY PIPE VALVE NOTES: MATERIALS, ARRANGEMENT AND INSTALLATION SHALL COMPLY WITH FEDERAL, STATE, AND LOCAL CODE REQUIREMENTS, INCLUDING NFPA 13, 101, AND OWNER'S INSURANCE UNDERWRITERS GUIDELINES. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS INCLUDING AIR COMPRESSOR AND MATERIALS. PROVIDE PIPE OR CABINET MOUNTED AIR COMPRESSOR (AS SPECIFIED), SUITABLE FOR INTENDED SERVICE, COMPLETE WITH HIGH/LOW AIR PRESSURE MAINTENANCE DEVICE, ALARM SWITCHES AND PRESSURE MAINTENANCE ALARM PANEL (NUMBER OF DEVICE MONITORS/ZONES AS REQUIRED). 1. 2. 3. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:19:58 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtFP00.00 RAE JMB 2247601 FIRE PROTECTION - LEGEND, SCHEDULES AND DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCRAE JMB Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV FIBERGLASS -1000 4 2 NOTES: 2. DESIGN BASIS: ZURN PROCEPTOR GMC 1000 SERIES OR ENGINEERS APPROVED EQUAL. PLAN MARK TYPE NOTES INTERCEPTOR SCHEDULE FIBERGLASS -500 6 3 3. DESIGN BASIS: ZURN PROCEPTOR OMC 500 SERIES OR ENGINEERS APPROVED EQUAL. PARKING GARAGE SI-1 SAND/OIL INTERCEPTOR GI-2 GREASE INTERCEPTOR FLOW (GPM) CAPACITY (GALLONS) IN/OUT (INCHES) SERVICE/ LOCATION PARKING GARAGE FABRICATED STEEL 10 3 1 GI-1 GREASE INTERCEPTOR TRASH ROOM 15 1. DESIGN BASIS: ZURN Z1170-400 OR ENGINEERS APPROVED EQUAL. FLOOR DRAIN GENERAL PURPOSE FD-G FLOOR DRAIN HEAVY DUTY FD-M FLOOR CLEAN OUT FCO WALL CLEAN OUT WCO YARD CLEAN OUT YCO DECK DRAIN FD-DD DOWNSPOUT NOZZLE DSN NON-FREEZE HOSE BIBB NFHB NON-FREEZE ROOF HYDRANT NFRH HOSE BIBB-LOOSE KEY HB-1 HOSE BIBB- WHEEL HANDLE HB-2 MINIMUM ROUGH-IN SIZES PLAN MARK WASTE CW HW DESCRIPTION VENT TP TRAP PRIMER VTR YCO WCO UP V --- VENT THRU ROOF YARD CLEANOUT WALL CLEANOUT PIPING TURNING UP VENT PIPING UNION EMERGENCY RAIN LEADER COMBINATION WASTE & VENT SOIL, WASTE PIPING (BELOW GROUND) SOIL, WASTE PIPING (ABOVE GROUND) HOSE BIBB/NON-FREEZE HOSE BIBB REDUCED PRESSURE BACKFLOW PREVENTER PRESSURE REDUCING VALVE HOT WATER RETURN PIPING GAS PIPING - MEDIUM PRESSURE COLD WATER PIPINGCW HD HUB DRAIN ST S S PD ST S,W S,W RPZ RD/ERD PRV STORM DRAINAGE PIPING ROOF DRAIN / EMERGENCY ROOF DRAIN --- PD O/H HWR HW PUMPED DISCHARGE P-TRAP OVER HEAD HOT WATER PIPING MG GW G ERL CWV HB/NFHB H.C. GV MG GW G FS HANDICAPPED GATE VALVE GREASE WASTE PIPING GAS PIPING - LOW PRESSURE FLOOR SINK FD FCO ERL DN CWV FLOOR DRAIN FLOOR CLEANOUT PIPING TURNING DOWN CD SYMBOL CONDENSATE DRAIN CV CD B/F B/G B/C CHECK VALVE BELOW COUNTER BELOW GRADE BELOW FLOOR A/P AFG AFF A/F ABBREVIATION A/C AD ACCESS PANEL ABOVE FINISHED GRADE ABOVE FINISHED FLOOR ABOVE FLOOR ABOVE CEILING AREA DRAIN DESCRIPTION PLUMBING LEGEND SA SHOCK ABSORBER HOT WATER RETURN BALANCING VALVEHWBV HEAT TRACED PIPINGHT NOTE: NOT ALL SYMBOLS SHOWN ARE NECESSARILY USED. DCO DOUBLE (2-WAY) CLEANOUT DOUBLE CHECK VALVEDCV BV BALL VALVE DSN DOWNSPOUT NOZZLE PLUMBING DRAIN/SPECIALTY SCHEDULE -- --SEE PLANS -- -- -- ---- -- ---- -- ---- -- -- -- ---- 3/4" ------ 3/4" ------ 1/2" ------ 1/2" ------ PLUMBING MATERIALS DOMESTIC HOT AND COLD WATER SYSTEMS MATERIALS:A. SEE PLANS SEE PLANS SEE PLANS SEE PLANS SEE PLANS B. C. D. E. F. JAY R. SMITH 2005B-L-B6-P050 CAST IRON, 6" SQUARE NICKEL BRONZE STRAINER AND TRAP PRIMER CONNECTION. PROVIDE BACKWATER VALVE. JAY R. SMITH 2142, CAST IRON, 12" DIAMETER WITH DUCTILE IRON GRATE , SEDIMENT BUCKET AND TRAP PRIMER CONNECTION. PROVIDE BACKWATER VALVE. PUBLIC SPACES MECHANICAL ROOM JAY R. SMITH 1412-HP, CAST IRON DRAIN WITH 13" SQUARE HEEL PROOF GRATE, DUCTILE IRON UNDER GRATE WITH NICKEL BRONZE STRAINER. -- FLOOR DRAIN HEAVY DUTY FD-PD -- --SEE PLANS PARKING DECK JAY R. SMITH 2142-M, CAST IRON DRAIN WITH 11-1/2" DUCTILE IRON GRATE AND SEDIMENT BUCKET. -- TRENCH DRAIN HEAVY DUTY FD-TD -- --SEE PLANS PARKING DECK ZURN Z-874-12, 12" WIDE, 4" OUTLET, DUCTILE IRON HEEL PROOF GRATE. -- PLANTER DRAIN FD-P -- --SEE PLANS JAY R. SMITH 2685, CAST IRON DRAIN WITH BRONZE STANDPIPE AND DOME. FIELD VERIFY EXACT HEIGHT REQUIRED. -- GREEN ROOF PLANTER DRAIN GR -- -- SEE PLANS JAY R. SMITH 1017-RBD, CAST IRON BODY WITH FLASHING CLAMP, PERFORATED STAINLESS STEEL EXTENSION, GRAVEL STOP AND ROUGH BRONZE DOME. COORDINATE EXACT REQUIRED EXTENSION HEIGHT WITH ARCHITECT. -- GREEN ROOF EMERGENCY PLANTER DRAIN GRE -- -- SEE PLANS JAY R. SMITH 1070-RBD, CAST IRON BODY WITH FLASHING CLAMP, PVC STANDPIPE, GRAVEL STOP AND ROUGH BRONZE DOME. COORDINATE EXACT REQUIRED STANDPIPE HEIGHT WITH ARCHITECT. -- SEE PLANS SEE PLANS ROOF DRAIN PRIMARY - POURED CONCRETE CONSTRUCTION RD -- --SEE PLANS JAY R. SMITH 1010-Y, CAST IRON BODY WITH COMBINED FLASHING AND GRAVEL STOP, CAST IRON DOME. ROOF DRAIN PRIMARY - STEEL CONSTRUCTION RD -- --SEE PLANS JAY R. SMITH 1015-Y-R-C, CAST IRON BODY WITH COMBINED FLASHING AND GRAVEL STOP, UNDER DECK CLAMP AND SUMP RECEIVER, ADJUSTABLE EXTENSION AND CAST IRON DOME. ROOF DRAIN SECONDARY ERD -- --SEE PLANS -- -- -- SEE PLANS JAY R. SMITH 1080-Y, CAST IRON BODY WITH COMBINED FLASHING AND GRAVEL STOP, CAST IRON DOME, 3" MINIMUM PVC STANDPIPE UNDER DOME, UNDER DECK CLAMP, SUMP RECEIVER AND EXTENSION AS REQUIRED. ZURN ZN-1400 DURO-COATED CAST IRON CLEANOUT WITH WATERTIGHT COUNTER-SUNK PLUG AND ADJUSTABLE SCORIATED SECURED TOP. ZURN ZS-1468 ROUND STAINLESS STEEL WALL ACCESS COVER WITH SECURING SCREW AND BRONZE RAISED HEX HEAD PLUG. ZURN Z-1402 DURO-COATED CAST IRON CLEANOUT WITH WATERTIGHT COUNTER-SUNK PLUG AND SCORIATED SECURED TOP WITH FRAME. INSTALL IN 18" X 18" x 4" THICK CONCRETE PAD. JAY R. SMITH 1770. WALL MOUNTED CAST BRONZE BODY AND FLANGE, NICKEL BRONZE FINISH. WOODFORD #24P WITH LOOSE TEE KEY AND VACUUM BREAKER, CHROME PLATED FOR USE IN PUBLIC AREAS. MOUNT 18" ABOVE FINISH FLOOR. WOODFORD #24P HOSE BIBB WITH WHEEL HANDLE AND VACUUM BREAKER, ROUGH BRASS, FOR USE IN NON-PUBLIC AREAS. MOUNT 18" ABOVE FINISH FLOOR. PROVIDE KEYED RECESSED BOX TYPE WALL HYDRANT FOR NON-FREEZING AREAS EQUAL TO WOODFORD B24 WITH ANTI-SIPHON VACUUM BREAKER. FOR AREAS SUBJECT TO FREEZING TEMPERATURES, PROVIDE KEYED RECESSED BOX TYPE FREEZELESS WALL HYDRANT EQUAL TO WOODFORD B65 WITH AUTOMATIC DRAINING ANTI-SIPHON VACUUM BREAKER. MOUNT MINIMUM 18" ABOVE FINISH GRADE. COORDINATE EXACT MOUTING HEIGHT WITH EXTERIOR FACADE. WOODFORD SRH-MS 3/4" ROOF MOUNT PEDESTAL NON-FREEZE HYDRANT COMPLETE WITH MOUNTING FLANGE AND SHROUD, MALE HOSE END OUTLET WITH DUAL CHECK BACKFLOW PREVENTER, SELF-DRAINING VENTURI. HUB DRAIN HD PROVIDE DEEP SEAL TRAP WITH AUTOMATIC TRAP PRIMER. PROVIDE INTEGRAL BACKWATER VALVE. SEE PLANS SEE PLANS ---- 1 S 2 S SINGLE UNIT BATHROOM SANITARY STACK 1 CW 1 HW PRESSURE ZONE SINGLE UNIT CW RISER STACK NOTES: 1. REFER TO RISER DIAGRAMS. 2. REFER TO FLOOR PLANS FOR STACK/RISER LOCATIONS PRESSURE ZONE SINGLE UNIT HW RISER STACK 3 S RISER & STACK DESIGNATION SCHEDULE SINGLE UNIT KITCHEN SINK WASTE STACK SINGLE UNIT WASHER BOX WASTE STACK 4 S SINGLE UNIT CONDENSATE COLLECTION STACK. CONNECT TO SANITARY SYSTEM. 1 S5 REFERENCE SYSTEM REFERENCE STORIES REFERENCE RISER TYPES PLUMBING NOTES 5. SANITARY AND DRAINAGE PIPING 2" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM, PIPING 3" AND LARGER SHALL BE SLOPED AT 1/8" PER FOOT MINIMUM. SANITARY PIPING 8" IN SIZE AND LARGER MAY BE SLOPED AT 1/16" FALL PER FOOT IF ALLOWED BY LOCAL AUTHORITY HAVING JURISDICTION (AHJ) 1. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ALL PLUMBING FIXTURES. 2. ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 2018 NC PLUMBING CODE WITH ALL APPLICABLE LOCAL AMENDMENTS, CODES AND ORDINANCES. 3. ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED FR0M THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR BE SUPPORTED FROM CEILING TILES. 4. WATER PIPING ROUTED ABOVE CEILING AND IN EXTERIOR WALLS SHALL BE ROUTED ON HEATED SIDE (UNDERSIDE) OF CEILING INSULATION AND HEATED SIDE (INSIDE) OF WALL INSULATION. 6. ALL HORIZONTAL DRAINS SHALL BE PROVIDED WITH CLEANOUTS LOCATED NOT MORE THAN 100 FEET APART. 7. CLEANOUTS SHALL BE PROVIDED AT THE BASE OF ALL VERTICAL DRAIN STACKS. 8. TOPS OF ALL FLOOR DRAINS AND CLEANOUTS SHALL BE SET FLUSH WITH FINISHED FLOOR. 9. TRAP PRIMERS ARE TO BE PROVIDED ON ALL FLOOR DRAINS AND HUB DRAINS. TP-L, LAVATORY WASTE TRAP PRIMERS ARE TO BE PROVIDED ON DRAINS IN PUBLIC RESTROOMS, GUEST ROOMS, AND OTHER AREAS WITH DRAINS ADJACENT TO LAVATORIES. TP-A AUTOMATIC TRAP PRIMERS ARE TO BE PROVIDED IN ALL OTHER REQUIRED LOCATIONS. TRAP GUARDS WILL BE ALLOWED WHERE ALLOWABLE BY THE AHJ IN LIEU OF TRAP PRIMERS. 10. PLUMBING AND FIRE PROTECTION PIPING ARE NOT TO BE INSTALLED IN ELECTRICAL ROOMS, CLOSETS, TELEPHONE ROOMS, OR ELEVATOR EQUIPMENT ROOMS EXCEPT PIPING SERVING THAT SPECIFIC ROOM. 11. LOCATE ALL SECTIONAL OR MAIN CONTROL VALVES WITHIN 1'-0" FROM ACCESS PANELS, CEILING TILES, OR OTHER POINT OF ACCESS. 12. ALL COLD WATER, HOT WATER AND DRAIN PIPING AT HANDICAPPED FIXTURES SHALL BE INSULATED WITH HANDI-LAV GUARD MODELS 102 AND 105 INSULATION KITS. 13. PROVIDE SHOCK ABSORBERS SIZED PER PDI SPECIFICATIONS ON ALL DOMESTIC WATER LINES SERVING FLUSH VALVE FIXTURES, WASHING MACHINES SUPPLIES, PRV STATIONS AND OTHER INSTALLATIONS WITH QUICK CLOSING VALVES. 14. PROVIDE A BASE CLEANOUT AT THE LOWEST LEVEL OF ALL SANITARY AND WASTE STACKS. BASE CLEANOUTS ON SOVENT STACKS SHALL BE LOCATED CONCEALED BEHIND THE WATER CLOSET TANK. 15. ALL SHOWER HEAD ARMS AND VALVES SHALL BE PROVIDED WITH ADDITIONAL BLOCKING AS REQUIRED AND RIGIDLY SECURED TO ADJACENT STRUCTURE. 16. ALL SHOWER HEADS SHALL BE INSTALLED WITH THE CENTER POINT OF THE SHOWER HEAD FACE LOCATED PER THE ARCHITECTURAL DRAWINGS. 17. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTERS AT ALL DOMESTIC WATER CONNECTIONS TO MECHANICAL EQUIPMENT, POOL AND IRRIGATION CONNECTIONS, AND VENDING EQUIPMENT CONNECTIONS AS REQUIRED BY LOCAL CODE AND AUTHORITIES. BACKFLOW PREVENTERS ARE TO BE LOCATED WITH A MINIMUM OF 1'-0" CLEARANCE AT THE LOWEST POINT AND AT NO MORE THAN 5'-0" ABOVE FLOOR AT THE HIGHEST POINT OF THE DEVICE. 18. PROVIDE MANUFACTURED EXPANSION DEVICE OR FABRICATED EXPANSION LOOP ON ALL PIPING SYSTEMS CROSSING BUILDING EXPANSION JOINTS. 19. CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND THE ELECTRICAL CONTRACTOR, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. 20. ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC. INSTALLED IN HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY. 21. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A MINIMUM PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. 22. ALL PIPE PENETRATIONS OF FIRE AND/OR SMOKE RATED ASSEMBLIES SHALL BE FIRE STOPPED AS REQUIRED TO RESTORE ASSEMBLY TO ORIGINAL INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE AS MANUFACTURED BY 3M COMPANY, CP25 CAULK, CS195 COMPOSITE PANEL, FS195 WRAP/SRINK, TREMCO, HILTI, METACAULK, NELSON, OR PSS 7900 SERIES SYSTEMS AS RECOMMENDED BY MANUFACTURER FOR PARTICULAR APPLICATIONS, OR EQUIVALENT SYSTEM AS APPROVED BY LOCAL CODE OFFICIALS. ALSO, REFER TO DIVISION 7 - THERMAL AND MOISTURE PROTECTION. 23. PROVIDE AN INLINE FILTER ON THE DOMESTIC WATER SUPPLY TO ALL ICE MACHINES, FILTRINE MODEL TMP1-07 OR ENGINEER APPROVED EQUAL. 24. ALL VENT THRU ROOF PENETRATIONS SHALL BE ROUTED TO TERMINATE AT THE LEAST VISIBLE LOCATION FROM THE ENTRY VIEW. 25. PLUMBING CONTRACTOR SHALL CONFIRM WITH ELECTRICAL CONTRACTOR THE REQUIRED SCCR RATINGS FOR ALL EQUIPMENT. NO EQUIPMENT SHALL BE ORDERED PRIOR TO CONFIRMATION OF SCCR VALUES. 26. A BACKWATER VALVE SHALL BE PROVIDED AT ALL HUB DRAINS AND FLOOR DRAINS CONNECTING TO THE STORMWATER DRAINAGE SYSTEM. COORDINATE REQUIREMENTS WITH ARCHITECT AND ALL PERTINENT TRADES PRIOR TO INSTALLATION. G. 27. MATERIALS FOR STORM AND DWV PIPING, FITTINGS AND APPURTENANCES IN BUILDINGS IN WHICH THE TOP OCCUPIED FLOOR EXCEEDS 75 FEET IN HEIGHT SHALL BE IN ACCORDANCE WITH SECTIONS 702.1 AND 702.4 OF THE 2018 NORTH CAROLINA PLUMBING CODE. 28. WHERE WATER PRESSURE WITHIN A BUILDING EXCEEDS 80 PSI STATIC, AN APPROVED WATER PRESSURE REDUCING VALVE CONFORMING TO ASSE 1003 OR CSA B356 WITH STRAINER SHALL BE INSTALLED TO REDUCE THE PRESSURE IN THE BUILDING WATER DISTRIBUTION PIPING TO NOT GREATER THAN 80 PSI STATIC. EXCEPTION: SERVICE LINES TO SILL COCKS AND OUTSIDE HYDRANTS, AND MAIN SUPPLY RISERS WHERE PRESSURE FROM THE MAINS IS REDUCED TO 80 PSI OR LESS AT INDIVIDUAL FIXTURES. UNDERGROUND DOMESTIC COLD WATER SYSTEM BASIS OF DESIGN: 1. DUCTILE IRON THICKNESS CLASS 51 FOR 3 INCH AND 4 INCH SIZE THICKNESS , CLASS 50 FOR 6 INCHES AND LARGER, ANSI A21.51, ASTM A746 WITH BITUMINOUS COATING OUTSIDE AND CEMENT MORTAR LINING INSIDE. DUCTILE IRON MECHANICAL OR PUSH-ON JOINTS AND FITTINGS ASNI/AWWA C110/A21.10. DEDUCTIVE ALTERNATES: 1. MAINS WHERE PRESSURE IS NO GREATER THAN 100 PSI: POLYVINYL CHLORIDE (PVC), 160 PSI WATER PIPING, ASTM D2241, SDR26 WITH MECHANICAL OR PUSH-ON JOINTS WITH NEOPRENE "O" RINGS, ASTM C3139. 2. MAINS WHERE PRESSURE IS GREATER THAN 100 PSI: POLYVINYL CHLORIDE (PVC), 200 PSI WATER PIPING, AWWA C900, 200 PSI, WITH MECHANICAL OR PUSH-ON JOINTS WITH NEOPRENE "O" RINGS, ASTM D3139. ABOVEGROUND DOMESTIC COLD WATER SYSTEM BASIS OF DESIGN: 1. POLYPROPYLENE PIPING, AQUATHERM GREEN PIPE SDR 7.4 FOR COLD AND HOT WATER SYSTEMS 3" AND SMALLER, OR SDR 11 FOR HOT WATER SYSTEMS 4" AND LARGER. PIPING, FITTINGS AND JOINTS TO COMPLY WITH NSF 61-G, AND NSF 372. PROVIDE PIPE WRAP OR INSULATION FOR PIPING IN ALL PLENUM APPLICATIONS THAT MEET ASTM E84. DEDUCTIVE ALTERNATE: 1. HOT AND COLD WATER SYSTEMS: CHLORINATED POLYVINYL CHLORIDE (CPVC) SCHEDULE 40, ASTM F-441 AND D-2846 . PIPING, FITTINGS AND JOINTS TO COMPLY WITH NSF 61-G, NSF-61 AND NSF 372. FITTINGS: SCHEDULE 40 SOCKET TYPE CPVC, ASTM F-439 AND F-441. JOINTS: SOLVENT CEMENT AND PRIMER FOR CPVC PIPING. HOT AND COLD WATER SYSTEMS WITHIN LIVING UNITS: 1. CROSS LINKED POLYETHYLENE (PEX) PLASTIC TUBING, PEX-A GRADE, ASTM F-876, ASTM F-877. PIPING, FITTINGS AND JOINTS TO COMPLY WITH NSF 61-G, NSF 61 AND NSF 372. UNDERGROUND SANITARY WASTE, VENT AND STORM DRAINAGE SYSTEMS BASIS OF DESIGN: 1. SERVICE WEIGHT HUB AND SPIGOT CAST IRON SOIL PIPE PER ASTM A-74, COATED ON OUTSIDE. FITTINGS: SERVICE WEIGHT HUB AND SPIGOT CAST IRON SOIL PIPE FITTINGS PER ASTM A-74, COATED ON OUTSIDE. JOINTS: NEOPRENE GASKET JOINTS PER ASTM C564 AND ASTM C1563. 2. NO-HUB CAST IRON SOIL PIPE PER CISPI 301 AND ASTM A888. FITTINGS: NO HUB CAST IRON FITTINGS PER CISPI 301 AND ASTM A888. JOINTS: CAST IRON MECHANICAL COUPLINGS WITH NEOPRENE GASKETS AND STAINLESS STEEL NUTS AND BOLTS. HEAVY DUTY TYPE 304 STAINLESS STEEL SHIELDED COUPLINGS, ASTM C1540. DEDUCTIVE ALTERNATE: 1. SCHEDULE 40 SOLID WALL DWV PVC PIPE, ASTM D1785. INSTALL PER ASTM D2321. FITTINGS: SCHEDULE 40 DWV PVC, SOCKET TYPE FITTINGS, ASTM D2665. JOINTS: SOLVENT JOINTS FOR PVC, ASTM D2564. PVC IS NOT ACCEPTABLE FOR WASTE PIPING RECEIVING DISCHARGE HIGHER THAN 130 DEGREES F. CAST IRON PIPING IS TO BE INSTALLED AT THE CENTRAL PLANT, MECHANICAL ROOMS AND AT ALL LAUNDRY AND KITCHEN EQUIPMENT DISCHARGES. ABOVE GROUND SANITARY WASTE, VENT AND STORM DRAINAGE SYSTEMS BASIS OF DESIGN: 1. NO-HUB CAST IRON SOIL PIPE PER CISPI 301 AND ASTM A888. FITTINGS: NO-HUB CAST IRON FITTINGS PER CISPI 301 AND ASTM A888. JOINTS: JOINTS FOR NO-HUB PIPE AND FITTINGS SHALL BE PER CISPI 310, WITH STAINLESS STEEL CLAMPS AND NEOPRENE SLEEVES CONFORMING TO ASTM D564. ALL CAST IRON PIPE AND FITTINGS SHALL CARRY AN NSF INTERNATIONAL LISTING. UNDERGROUND NATURAL GAS PIPING AND FITTINGS: 1. SCHEDULE 40 BLACK STEEL PIPE, ASTM A53 WITH POLYETHYLENE JACKET, WELDED JOINTS AND STANDARD WEIGHT BLACK STEEL BUTT WELDED OR SOCKET WELD FITTINGS, ASTM A243 OR PRESS CONNECT FITTINGS ANSI LC-4/CSA 6.32 (VIEGA MEGAPRESS) ABOVE GROUND NATURAL GAS PIPING AND FITTINGS: 1. SCHEDULE 40 BLACK STEEL PIPE, ASTM A53 WITH WELDED JOINTS AND STANDARD WEIGHT BLACK STEEL BUTT WELD FITTINGS, ASTM A234 OR SOCKET WELD FITTINGS, ASTM A105. 2. SCHEDULE 40 BLACK STEEL PIPE, ASTM A53 WITH SCREWED JOINTS AND 150 POUND THREADED MALLEABLE IRON FITTINGS, ASTM B.16.3. 3. SCHEDULE 40 BLACK STEEL PIPE, ASTM A53, WITH PRESS CONNECT JOINTS (VIEGA MEGAPRESSG) ANSI LC-4/CSA 6.32. THE FOLLOWING SYSTEMS AND EQUIPMENT SHALL BE INSULATED: 1. ALL DOMESTIC COLD WATER PIPING SUBJECT TO FREEZING TEMPERATURES. 2. ALL HOT WATER AND HOT WATER RETURN PIPING. 3. ALL HORIZONTAL STORM DRAIN PIPING AND ROOF DRAIN BODIES. PROVIDE ELECTRIC HEAT TRACING ON ALL DOMESTIC WATER PIPING AND SANITARY TRAPS EXPOSED IN AREAS SUBJECT TO FREEZING TEMPERATURES. 29. IN PUBLIC USE AREAS WHERE ADA COMPLIANT PLUMBING FIXTURES ARE REQUIRED, A THERMOSTATIC TEMPERATURE MIXING VALVE IN CONFORMANCE WITH ASSE 1070 SHALL BE PROVIDED AT EACH LAVATORY AND SINK LOCATION. SET OUTLET TEMPERATURE AT 110 DEGREES F. MAXIMUM. FOR PUBLIC USE LAVATORIES, PROVIDE A 0.5 GPM AERATOR AT EACH LOCATION. FOR PUBLIC USE SINKS, PROVIDE A 1.0 GPM AERATOR AT EACH LOCATION. PUBLIC USE LAVATORY FAUCETS SHALL BE METERING WHERE REQUIRED IN ACCORDANCE WITH SECTION 604.4.1 OF THE 2018 NORTH CAROLINA PLUMBING CODE. DEDUCTIVE ALTERNATE: (ONLY ACCEPTABLE FOR PHASE 2 NON-HIGH RISE OF PROJECT) 1. POLYVINYL CHLORIDE (PVC), SCHEDULE 40 DWV PVC PIPE, ASTM D1785, FITTINGS: SCHEDULE 40 DWV PVC, SOCKET TYPE FITTINGS, ASTM D2665. JOINTS: SOLVENT JOINTS FOR PVC, ASTM D2564. PVC IS NOT ACCEPTABLE IN PLENUM CEILINGS OR FOR WASTE PIPING RECEIVING DISCHARGE HIGHER THAN 130 DEGREES F. (PHASE 1 HIGH RISE) 3. 1.WORK TO INCLUDE PIPING FROM GAS METER TO GAS FIRED EQUIPMENT. PLUMBING CONTRACTOR TO PROVIDE SHUT-OFF VALVE, DIRT TRAP, AND PRESSURE REGULATOR AT ALL GAS FIRED EQUIPMENT. ALL WORK SHALL BE IN ACCORDANCE WITH ALL APPLICABLE LOCAL CODE REQUIREMENTS AND THE PROVISIONS OF THE 2018 NORTH CAROLINA FUEL GAS CODE (NCFGC). THE CONTRACTOR SHALL SUPPLY ALL PERMITS, FEES, AND LICENSES REQUIRED FOR THE WORK AND FOR ALL INSPECTIONS REQUIRED. PIPE 2" AND SMALLER MAY BE SCHEDULE 40 STEEL WITH THREADED MALLEABLE FITTINGS, PIPE 2-1/2" AND GREATER MAY BE SCHEDULE 40 STEEL WITH BUTT-WELDED FITTINGS AND JOINTS. ALL VALVES SHALL BE AGA/CGA CERTIFIED AND APPROVED WITH STAMP ON VALVE. ALL PIPING EXPOSED TO THE OUTDOORS OR RUN IN UNCONDITIONED SPACES SHALL BE PAINTED WITH TWO COATS OF RUST RESISTANT ENAMEL. ALL GAS PIPING WITH A SERVICE PRESSURE GREATER THAN 0.5 PSI MUST BE IDENTIFIED PER NCFGC 401.5. PRESSURE TEST PORTS MUST BE PROVIDED AT ALL MP REGULATORS IN ACCORDANCE TO NCFGC 410.2. ALL GAS PIPING SUPPORT MUST COMPLY WITH NCFGC T.415.1. 2. 4. 5. 6. 7. 8. 9. FUEL GAS PIPING FLOW TEST DATA SCHEDULE LOCATION OF TEST HYDRANT DATE OF TEST TIME OF DAY OF TEST STATIC PRESSURE RESIDUAL PRESSURE FLOW (GPM) UPON AWARD OF THE CONTRACT, THE FIRE PROTECTION CONTRACTOR SHALL PERFORM A FLOW TEST ON THE TWO HYDRANTS NEAREST THE SITE AND FORWARD THE TEST DATA TO THE ENGINEER AND ARCHITECT. THE FOLLOWING WATER PRESSURE/FLOW DATA WAS OBTAINED FROM: CHARLOTTE FIRE DEPARTMENT 48 HOUR HIGH PRESSURE 48 HOUR LOW PRESSURE 48 HOUR AVERAGE PRESSURE HYDRANT NUMBER TYPE/OWNER PSI PSI GPM -- -- ----- ----- ----- ------ PSI PSI --- --- PSI--- ----- PUBLIC PUMP ROOM TRIPLEX ---- ---- 3450 (3) ---HP 1 BP-1 POTABLE WATER BOOSTER PLAN MARK SERVICE/ LOCATION TYPE FLOW (GPM) HEAD (FT.)RPM HP NOTES DOMESTIC WATER BOOSTER PUMP SCHEDULE NOTES: 1. HY-FAB NO. 8----208 TRIPLEX. THREE -- HP PUMPS. PACKAGE SHALL BE CONSTRUCTED ON A RIGID STRUCTURAL STEEL BASE AND PUMPS/MOTORS SHALL BE SUPPORTED BY STRUCTURE. HEADERS SHALL BE 6" 304 STAINLESS STEEL WITH GROOVED CONNECTIONS ON BOTH ENDS. ONE END OF EACH HEADER SHALL BE CAPPED WITH A GROOVED CAP AND COUPLING. SUCTION AND DISCHARGE CONNECTIONS MAY EACH BE MADE ON EITHER SIDE (I.E. LEFT OR RIGHT). BOOSTER SHALL BE SUPPLIED WITH SERVICABLE PILOT OPERATED ANGLE CHECK VALVES EQUAL TO CLA-VAL 81 SERIES. FURNISH VARIABLE SPEED CONTROLLER WITH SUCTION AND DISCHARGE PRESSURE TRANSMITTERS AND DISCHARGE TEMPERATURE SENSOR. FURNISH CONTROLS IN NEMA 1 ENCLOSURE. FURNISH LOW SUCTION PRESSURE SHUTDOWN. FURNISH SINGLE POINT POWER CONNECTION WITH MAIN DISCONNECT REFERENCE SPECIFICATION FOR ADDITIONAL CONTROL REQUIREMENTS PACKAGE SHALL BE HYDROSTATICALLY AND FLOW TESTED PRIOR TO SHIPMENT. PROVIDE ASME CODE AND NB STAMPED 170 GALLON, 200 PSIG RATED HYDROPNEUMATIC TANK. FURNISH CONNECTION WITH DRAIN FOR HYDROPNEUMATIC TANK ON DISCHARGE HEADER. BPA-1 RPZ (REDUCED PRESSURE ZONE) FEBCO LF880V VERTICAL 6" 1-5 SYMBOL DOMESTIC WATER BACKFLOW PREVENTER SCHEDULE MODEL TYPE SERVICE SIZE NOTES DOMESTIC WATER NOTES: 1. ASSEMBLY SHALL BE INSTALLED PER ALL PERTINENT STATE, NFPA AND LOCAL JURSIDICTION REQUIREMENTS. 2. PROVIDE AIR GAP AND PIPE DISCHARGE INDIRECTLY TO FLOOR DRAIN, HUB DRAIN, OR THROUGH EXTERIOR WALL TO ATMOSPHERE. 3. THERE SHALL BE NO TAPS, PIPING BRANCHES, UN-APPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. CONNECTION POINTS, OR OTHER WATER USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND CHARLOTTE WATER REQUIRED BACKFLOW PREVENTER. 4. EACH CHARLOTTE WATER REQUIRED BACKFLOW PREVENTER IS REQUIRED TO BE TESTED BY A CHARLOTTE WATER APPROVED CERTIFIED TESTER PRIOR TO PLACING THE WATER SYSTEM IN SERVICE. 5. INSTALLATION INSIDE BUILDING: CLEARANCES SHALL BE 30" FROM WALL OR ANY OBSTRUCTION ON THE SIDE UTILIZED FOR TESTING AND 12" FROM OTHER SIDE. SP-1 ELEVATOR SUMP PIT ELEVATOR SUMP PIT SUBMERSIBLE 50 25 3450 0.75 1,4,7 NOTES: 1. DESIGN BASIS: STANCOR PUMPS MODEL SEW-75. PROVIDE CONTROLLER, AUTOMATIC OPERATION. 4. 115V, SINGLE PHASE 3/4 HP. 7. ELEVATORS ARE TRACTION TYPE (NON-HYDRAULIC). PLAN MARK SERVICE/ LOCATION TYPE FLOW (GPM)HEAD (FT.)RPM HP NOTES ELEVATOR PUMP SCHEDULE (TRACTION ELEVATORS) SP-2 ELEVATOR SUMP PIT ELEVATOR SUMP PIT SUBMERSIBLE 100 25 3450 1.5 2,5,7 SP-3 ELEVATOR SUMP PIT ELEVATOR SUMP PIT SUBMERSIBLE 150 20 3450 2.0 3,6,7 2. DESIGN BASIS: STANCOR PUMPS MODEL SEW-150. PROVIDE CONTROLLER, AUTOMATIC OPERATION. 3. DESIGN BASIS: STANCOR PUMPS MODEL SEW-200. PROVIDE CONTROLLER, AUTOMATIC OPERATION. 5. 115V, SINGLE PHASE 1.5 HP. 6. 208V, SINGLE PHASE 2.0 HP. WATER CLOSET WC-1 3" 2" 1/2" --- WATER CLOSET WC-1A 3" 2" 1/2" --- LAVATORY LAV-1 2" 1-1/2" 1/2" 1/2" LAVATORY LAV-1A 2" 1-1/2" 1/2" 1/2" KITCHEN SINK KS-1 2" 1-1/2" 1/2" 1/2" KITCHEN SINK KS-1A 2" 1-1/2" 1/2" 1/2" ICE MAKER OUTLET BOX IMB --- --- 1/2" --- WASHING MACHINE OUTLET BOX WMB 2" 2" 1/2" 1/2" BATHTUB BT-1 2" 1-1/2" 1/2" 1/2" MINIMUM ROUGH-IN SIZES PLAN MARK WST & VENT CW HW DESCRIPTION PLUMBING FIXTURE SCHEDULE LAVATORY LAV-3 2" 1-1/2" 1/2" 1/2" AMENITY SINK S-1 2" 1-1/2" 1/2" 1/2" LAVATORY LAV-2 2" 1-1/2" 1/2" 1/2" WATER CLOSET WC-2 3" 2" 1"--- MINIMUM ROUGH-IN SIZES PLAN MARK WST & VENT CW HW DESCRIPTION PLUMBING FIXTURE SCHEDULE (AMENITIES) EVOLUTION PLUTONIUM SERIES E-PT-1813, PORCELAIN UNDERMOUNT, EXT: 20 1/3"X15"X7", INT: 18"X13"X7". DELTA PRECEPT, SINGLE HANDLE CENTERSET BATHROOM FAUCET #P191102LF, 1.2GPM RP82293 INLINE ADAPTOR FOR 1.0GPM EVOLUTION MERCURY SERIES E-MR-2318 (GRID:MR-G-2318), 18 GAUGE, CENTER DRAIN, SINGLE UNDERMOUNT, 23.5X17.75X9D IPS 87980 ICE MAKER BOX W/ HAMMER ARRESTER. PROVIDE FIRE RATED OUTLET BOXES LOCATED IN RATED WALLS. IPS 85714 WASHING MACHINE BOX WITH HAMMER ARRESTERS. PROVIDE FIRE RATED OUTLET BOXES LOCATED IN RATED WALLS. KOLHER HIGHCLIFF K096057-B ONE PIECE ELONGATED TOILET. KOHLER K-7521 FLUCH VALVE 1.28 GPF. ELONGATED FRONT PLASTIC WHITE TOILET SEAT. FIXTURE TO BE A.D.A. COMPLIANT. KOHLER K-2028-8-0 WALLMOUNT BATHROOM SINK. WHITE FINISH. PFISTER LG49-DAOK FAUCET. FIXTURE TO BE ADA COMPLIANT. PROVIDE LEONARD 170-LF MIXING VALVE. KOHLER K-2882 UNDERCOUNTER BATHROOM SINK. BLACK FINISH. MAC FA400-1201 FAUCET. FIXTURE TO BE ADA COMPLIANT. PROVIDE LEONARD 170-LF MIXING VALVE. ELKAY LRAD221955 DROP IN KITCHEN SINK W/ SINGLE HOLE. 22" x 19-1/2" x 5-1/2" BOWL DIMENSIONS. WHITE FINISH. KOHLER K-7506 FAUCET. VIBRANT STAINLESS FINISH. FIXTURE TO BE ADA COMPLIANT. PROVIDE LEONARD 170-LF MIXING VALVE. (DWELLING UNITS) BATHTUB BT-1A 2" 1-1/2" 1/2" 1/2" SHOWER SH-1 2" 1-1/2" 1/2" 1/2" STERLING VIKRELL 71041120-0, DELTA PRECEPT, TUB SHOWER TRIM KIT #PTT188792-BN + RP62734 FLOW REGULATOR WASHER FOR 1.5GPM SHOWER SH-1A 2" 1-1/2" 1/2" 1/2" ELECTRICAL WATER COOLER 2" 1-1/2" 1/2" 1/2" EWC-1 ELKAY LZWS-LRPBM28K WALL MOUNTED BOTTLE FILLING STATION WITH BI-LEVEL INTEGRAL SWIRLFLO ® FOUNTAIN, REFRIGERATED FILTERED STAINLESS. URNIAL UR-1 2" 2" 3/4"---KOLHER K-991-ET HIGH EFFICIENCY, LOW CONSUMPTION. OPERATES AT 0.125GPF TO 1.0GPF. PROVIDE JAY R. SMITH 635 CARRIER. MOUNT AT STANDARD HEIGHT. AMENITY SINK S-2 2" 1-1/2" 1/2" 1/2" ELKAY ELUHAD121245 UNDERMOUNT ADA SINK. 14 1/2" x 14-1/2" x 4-3/8" BOWL DIMENSIONS. STAINLESS STEEL FINISH. DELTA 4159-DST FAUCET. MATTE BLACK FINISH. FIXTURE TO BE ADA COMPLIANT. PROVIDE LEONARD 170-LF MIXING VALVE. AMENITY SINK S-3 2" 1-1/2" 1/2" 1/2" ELKAY ELUHAD161650 UNDERMOUNT ADA SINK. 18 1/2" x 18-1/2" x 4-7/8" BOWL DIMENSIONS. STAINLESS STEEL FINISH. KOHLER PURIST K-7507 FAUCET. VIBRANT STAINLESS FINISH. FIXTURE TO BE ADA COMPLIANT. PROVIDE LEONARD 170-LF MIXING VALVE. BAR SINK PET SPA KOHLER KINGSTON #K-25087, TWO-PIECE ELONGATED 1.28 GPF, FLOOR MOUNT, LEFT HAND LEVER, 29 7/8"L X 18 3/4"W X 29 1/2"H X 14 1/2"SH. BREVIA QUIET-CLOSE ELONGATED TOILET SEAT KOHLER KINGSTON #K-25087, TWO-PIECE ELONGATED 1.28 GPF, FLOOR MOUNT, LEFT HAND LEVER, 29 7/8"L X 18 3/4"W X 29 1/2"H X 14 1/2"SH. BREVIA QUIET-CLOSE ELONGATED TOILET SEAT STERLING 72131100 ENSEMBLE SHOWER BASIN, DELTA PRECEPT, SHOWER ONLY TRIM KIT# PTT188782 + RP62734 FLOW REGULATOR WASHER FOR 1.5GPM EVOLUTION MERCURY SERIES E-MR-2318 (GRID:MR-G-2318), 18 GAUGE, CENTER DRAIN, SINGLE UNDERMOUNT, 23.5X17.75X9D EVOLUTION PLUTONIUM SERIES E-PT-1813, PORCELAIN UNDERMOUNT, EXT: 20 1/3"X15"X7", INT: 18"X13"X7". DELTA PRECEPT, SINGLE HANDLE CENTERSET BATHROOM FAUCET #P191102LF, 1.2GPM RP82293 INLINE ADAPTOR FOR 1.0GPM STERLING VIKRELL 71041120-0, DELTA PRECEPT, TUB SHOWER TRIM KIT #PTT188792-BN + RP62734 FLOW REGULATOR WASHER FOR 1.5GPM STERLING 72131100 ENSEMBLE SHOWER BASIN, DELTA PRECEPT, SHOWER ONLY TRIM KIT# PTT188782 + RP62734 FLOW REGULATOR WASHER FOR 1.5GPM WALK-THRU TUB BT-2 2" 1-1/2" 1/2" 1/2" GROMMER'S BEST 48" WLK-THRU TUB. STAINLESS STEEL FINISH. 49 1/2" x 26" x 57 1/2" TUB DIMENSIONS. PROVIDE ZURN Z1175 HAIR INTERCEPTOR.PET SPA WALK-IN TUB BT-3 2" 1-1/2" 1/2" 1/2" GROMMER'S BEST 48" WLK-THRU TUB. STAINLESS STEEL FINISH. 49 1/2" x 26" x 57 1/2" TUB DIMENSIONS. FIXTURE TO BE ADA COMPLIANT. PROVIDE ZURN Z1175 HAIR INTERCEPTOR. PET SPA RESOURCE ROOM SINK FIAT TSB-3000 TERAZZO 24" X 24" X 12". FIAT 830AA FAUCET. PROVIDE FIAT 832-AA HOSE BRACKET AND 889-CC MOP HANGER. FAUCET INCLUDES VACUUM BREAKER, BUILT-IN STOPS, LEVER HANDLES, HOSE OUTLET AND BUCKET HOOK WITH BRACE. MOP SINK MS-1 3" 2" 1/2" 1/2" UTILITY SINK US-1 2" 1-1/2" 1/2" 1/2" FLOOR MOUNTED 18 GAL TUB , MUSTEE 19 F MUSTEE #93.600 WATER CLOSET WC-3 3" 2" 1/2" --- KOHLER KINGSTON #K-25087, TWO-PIECE ELONGATED 1.28 GPF, FLOOR MOUNT, LEFT HAND LEVER, 29 7/8"L X 18 3/4"W X 29 1/2"H X 14 1/2"SH. BREVIA QUIET-CLOSE ELONGATED TOILET SEAT WHE-1 WATER HEATER ONE BEDROOM SINGLE BATH UNITS WATER CONNECTION SIZES PLAN MARK CW HW DESCRIPTION PLUMBING WATER HEATER SCHEDULE 3/4" 3/4" WHE-4 WATER HEATER AMENITY AREA 1/2" 1/2" WHE-6 WATER HEATER MOP RECEPTOR 3/4" 3/4" BRADFORD WHITE MODEL RE240LN6, 37 GALLON "LOW-BOY" ELECTRIC WATER HEATER, 21 GPH RECOVERY @ 90 DEGREES F. TEMPERATURE RISE, TWO (2) 4.5KW ELEMENTS WIRED FOR NON-SIMULTANEOUS OPERATION, 4.5KW @ 208V/1PH. PROVIDE AMTROL ST-5C-DD THERMAL EXPANSION TANK. DISCHARGE PAN INDIRECTLY TO HUB DRAIN. WHE-2 WATER HEATER TWO BEDROOM TWO BATH UNITS 1" 1"ELECTRIC WATER HEATER, 21 GPH RECOVERY @ 90 DEGREES F. TEMPERATURE RISE, TWO (2) 4.5 KW ELEMENTS WIRED FOR NON-SIMULTANEOUS OPERATION, 4.5 KW @ 208V/1PH. PROVIDE AMTROL ST-5C-DD THERMAL EXPANSION TANK. DISCHARGE PAN INDIRECTLY TO HUB DRAIN. WHE-5 WATER HEATER AMENITY AREA 1/2" 1/2" EEMAX - MODEL EX4208T - SERIES ONE, THERMOSTATIC POINT OF USE - ELECTRIC WATER HEATER - 4.1KW @ 208V/1PH. TEMPERATURE RISE OF 56 DEGREES F. AT A FLOW OF 0.5 GPM. SET TEMPERATURE AT 110 DEGREES F. MAXIMUM. PROVIDE EEMAX 0.5 GPM AERATOR AT EACH LOCATION. EEMAX - MODEL EX8208T - SERIES ONE, THERMOSTATIC POINT OF USE - ELECTRIC WATER HEATER - 8.3KW @ 208V/1PH. TEMPERATURE RISE OF 57 DEGREES F. AT A FLOW OF 1.0 GPM. SET TEMPERATURE AT 110 DEGREES F. MAXIMUM. PROVIDE EEMAX 1.0 GPM AERATOR AT EACH LOCATION. BRADFORD WHITE MODEL RE250LN6, 47 GALLON "LOW-BOY" WHE-3 WATER HEATER THREE BEDROOM TWO BATH UNITS 1" 1"ELECTRIC WATER HEATER, 21 GPH RECOVERY @ 90 DEGREES F. TEMPERATURE RISE, TWO (2) 4.5 KW ELEMENTS WIRED FOR NON-SIMULTANEOUS OPERATION, 4.5 KW @ 208V/1PH. PROVIDE AMTROL ST-5C-DD THERMAL EXPANSION TANK. DISCHARGE PAN INDIRECTLY TO HUB DRAIN. PROVIDE WATTS BRADFORD WHITE MODEL RE250LN6, 47 GALLON "LOW-BOY" MODEL LFMMV-HTK HOT WATER TANK CAPACITY EXTENDER. & DOG SPA BRADFORD WHITE MODEL RE240LN6, 37 GALLON "LOW-BOY" ELECTRIC WATER HEATER, 21 GPH RECOVERY @ 90 DEGREES F. TEMPERATURE RISE, TWO (2) 4.5KW ELEMENTS WIRED FOR NON-SIMULTANEOUS OPERATION, 4.5KW @ 208V/1PH. PROVIDE AMTROL ST-5C-DD THERMAL EXPANSION TANK. DISCHARGE PAN INDIRECTLY TO HUB DRAIN. PROVIDE HOLDRITE MODEL 50-SWHP-WM WALL MOUNTED WATER HEATER PLATFORM. COORDINATE LOCATION WITH ARCHITECT PRIOR TO INSTALLATION. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:19:58 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP00.00 RAE JMB 2247601 PLUMBING LEGEND, SCHEDULES AND NOTES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCRAE JMB PLUMBING SHEET INDEX FP00.00 FIRE PROTECTION - LEGEND, SCHEDULES AND DETAILS P00.00 PLUMBING LEGEND, SCHEDULES AND NOTES P00.01 PLUMBING DETAILS P00.02 PLUMBING DETAILS P00.03 RISER DIAGRAMS P00.04 RISER DIAGRAMS P00.05 RISER DIAGRAMS P00.06 RISER DIAGRAMS P01.01 LEVEL 1 - UNDERFLOOR - SITE PLAN P01.03 LEVEL 3 - FLOOR PLAN - SITE PLAN P02.01C-UF LEVEL 1 - UNDER FLOOR - AREA C P02.02A LEVEL 2 - FLOOR PLAN - AREA A P02.02B LEVEL 2 - FLOOR PLAN - AREA B P02.02C LEVEL 2 - FLOOR PLAN - AREA C P02.03A LEVEL 3 - FLOOR PLAN - AREA A P02.03B LEVEL 3 - FLOOR PLAN - AREA B P02.03C LEVEL 3 - FLOOR PLAN - AREA C P02.04A LEVEL 4 - FLOOR PLAN - AREA A P02.04B LEVEL 4 - FLOOR PLAN - AREA B P02.04C LEVEL 4 - FLOOR PLAN - AREA C P02.05A LEVEL 5 - FLOOR PLAN - AREA A P02.05B LEVEL 5 - FLOOR PLAN - AREA B P02.05C LEVEL 5 - FLOOR PLAN - AREA C P02.06A LEVEL 6 - FLOOR PLAN - AREA A P02.06B LEVEL 6 - FLOOR PLAN - AREA B P02.06C LEVEL 6 - FLOOR PLAN - AREA C P02.07A LEVEL 7 - FLOOR PLAN - AREA A P02.07B LEVEL 7 - FLOOR PLAN - AREA B P02.07C LEVEL 7 - FLOOR PLAN - AREA C P02.08A LEVEL 8 - FLOOR PLAN - AREA A P02.08B LEVEL 8 - FLOOR PLAN - AREA B P02.08C LEVEL 8 - FLOOR PLAN - AREA C P02.09A LEVEL 9-10 - FLOOR PLAN - AREA A P02.09B LEVEL 9-10 - FLOOR PLAN - AREA B P04.01 UNIT PLANS P04.02 UNIT PLANS Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV METER 2" 5" 5" 4" x 4" ELAST-O-RIB PAD (TYPICAL)TABLE 802.2 OF THE PLUMBING CONTRACTOR GAP PER CHAPTER 8, CODE (IPC) LATEST EDITION INTERNATIONAL PLUMBING REQUIRED MINIMUM AIR SHALL PROVIDE THE NOTE: UNIT ISOLATION VALVE. WIRELESS METER AND TRANSMITTER LOCATED ADJACENT TO WATER HEATER. UNIT WATER SERVICE REPEATER LOCATED IN ATTIC OF APARTMENT BUILDING. COORDINATE LOCATION WITH ELECTRICAL DRAWINGS. DATA CONCENTRATOR AND COMMUNICATOR LOCATED IN CLUBHOUSE. COORDINATE LOCATION WITH ELECTRICAL DRAWINGS. DATA OUTLET - BY OTHERS WATER RISER RADIO SIGNAL RADIO SIGNALREPEATER WATER SUB METERING SYSTEM SHALL BE BY ION SMART METER BY ION ENERGY SERVICES. SYSTEM SHALL INCLUDE ONE REMOTE WITH INTEGRATED TRANSMITTER PER DWELLING UNIT. EACH BUILDING SHALL HAVE A REPEATER LOCATED IN THE ATTIC AND DATA CONCENTRATOR AND COMMUNICATOR (DCC) LOCATED IN THE CLUBHOUSE. PLUMBER TO COORDINATED LOCATION OF POWER SERVICES FOR REPEATER AND DCC WITH THE ELECTRICAL CONTRACTOR. ALL EQUIPMENT SHALL BE PROVIDED UNDER THE PLUMBING CONTRACT UNLESS DIRECTED OTHERWISE BY THE OWNER OR GENERAL CONTRACTOR. PIPE RISER RISER CLAMP & SUPPORT (NOTE 2) SEE NOTE 3 FLOOR SLAB FLOOR SLAB PIPE RISER SCHEDULE 40 PIPE SLEEVE 2 PIPE SIZES LARGER THAN RISER, FILLED WITH APPROVED FIRE SAFING. NOTES: 1. ALL FLOOR PENETRATIONS SHALL BE SEALED AND FIREPROOFED. 2. IN PUMP ROOMS, MECHANICAL ROOMS, PENTHOUSES, AND OTHER LOCATIONS WHERE WATER WOULD PERIODICALLY BE ON THE FLOOR, SLEEVES SHALL EXTEND 2" ABOVE THE FLOOR. RISER CLAMPS SHALL NOT REST ON SLEEVES. 3. FOR WATERPROOF INSTALLATIONS A FLANGE SHALL BE WELDED TO THE MIDPOINT OF THE SLEEVE AND THE ENTIRE ASSEMBLY GALVANIZED AFTER FABRICATION. RISER SIZE 6" PIPE & LARGER 2" BALD HEADED NIPPLE (TACK-WELD TO RISER CLAMP) 2" SCHEDULE 40 COUPLING WELDED TO 4" x 4" x 1/4" STEEL PLATE RISER SIZE 5" PIPE & SMALLER 3/4" BALD HEADED NIPPLE (TACK-WELD TO RISER CLAMP) 3/4"SCHEDULE 40 COUPLING WELDED TO 2" x 2" x 1/8" STEEL PLATE RISER FRICTION CLAMP FILL ANNULAR SPACE WITH U.L. LISTED FIRE RESISTANT MATERIAL TRAPEZE HANGER W/ NEOPRENE PAD 3/8" ROD FOR 5" & SMALLER, 1/2" ROD FOR 6" & LARGER. HOLD TIGHT TO UNDERSIDE OF SLAB FLOOR SLAB CANTED CLAMPS RODS MUST WRAP AROUND LUG ON FITTING SLEEVE (SIZE LARGE ENOUGH TO ALLOW HUB TO TOUCH UNDERSIDE OF SLAB) FILL ANNULAR SPACE WITH U.L. LISTED FIRE RESISTANT MATERIAL NOTE: CONTRACTOR SHALL USE THIS BOTTOM OF RISER SUPPORT FOR ALL WASTE AND STORM RISERS. PLANS FOR SIZE AIR GAP AS REQUIRED OPEN SITE DRAIN WITH EXTEND DRAIN PIPE INTOUP TURN HUB OF PIPE 6" MAX. FIN. FL. WASTE PIPE. REFER TO 2" MIN. PER IPC S.F.0.51S.F. S.F.2.5 S.F.1.5 S.F.1 S.F.7 S.F.3 S.F.2 9 5 S.F. S.F. S.F.3 1.5 S.F. 8 S.F. 4 S.F. 2 S.F. 1 S.F. 12" 8" 6" 4" BEND 22 1/2 BEND 45 BEND 90 DEAD ENDS TEES & SIZE PIPE THRUST BLOCK AREAS 12 BRASS CLEANOUT PLUG COUNTERSINK SCREW CLEANOUT COVER FINISHED FLOOR COVERING AS REQUIRED PVC SIZE AS NOTED ON PLANS SANITARY TEE PVC COMBINATION COLLAR ADJUSTABLE CLAMPING EARTH FILL VENT PIPE UP OATEY "QUADTRO" 1/2" PIPE OR COPPER TUBING FLOOR SEE ARCHITECTURAL PLANS 2" INLET SINGLE LEVER WASHER BOX DRAIN AND TRAP WASTE PIPE DOWN FOR FLOOR CONSTRUCTION TYPE SEE PLANS FOR SIZE SEE PLANS FOR SIZE FROM WASHER MODEL #38545 HW & CW SHUT-OFF SHOCK ARRESTORS CAULKED JOINT. GASKETED JOINTS MAY BE USED IF ALLOWED BY LOCAL AUTHORITY. PROVIDE WITH THREADED AT REQUIRED LOCATIONS.TRAP PRIMER CONNECTION ADJUSTABLE STRAINER FIN. FLOOR FLASHING WITH SEDIMENT BUCKETDRAIN TO BE PROVIDED (TYPE K AND TYPE F DRAINS)AT SPECIFIED LOCATIONS FINISHED GRADE FLOW CONCRETE COLLAR 4" THICK SIZE AS NOTED ON PLANS TYPICAL CLEANOUT PVC 4" WITH STRUCTURAL DRAWINGS. SIZE OF OPENING IN ROOF DECK TO BE AS SMALL AS POSSIBLE COORDINATE TO ARCHITECTURAL DRAWINGS. FOR ROOF CONSTRUCTION TYPE . REFER COUNTER FLASHING AS REQUIRED, CAULK AIRTIGHT SLEEVE ROOF CONSTRUCTION FLASHING AND INCREASER WHEN REQUIRED 2. 1. NOTES: THRU ROOF VENT STACK VENT LINES 2" 6" LEAD FLASHING TURNED DOWN INTO VENT PIPE VENT STACK ACCESS COVER NO HUB WITH SURFACE FINISHED WALL CLEANOUT TEE CLEANOUT PLUG THREADED ACCESS COVER CLEANOUT FERRULE & BRONZE SCREW PLUG SET FLUSH IN ADJACENT SURFACE TYPICAL YCO, (WHERE SHOWN ON DRAWINGS OR AS REQUIRED. BY CODE) SHORT SWEEP 7 1/2" (-) 13" START I.E. SLAB CAULK JOINT 6" ROOF DRAIN / EMERGENCY ROOF DRAIN SCALE: SCALE: 5 VENT STACK DETAIL 4 FLOOR DRAIN DETAIL NTS SCALE:6 WALL CLEANOUT DETAIL SCALE:7 WASHER BOX DETAIL SCALE: FLOOR CLEANOUT DETAIL NTS NTS NTS SCALE: 8 YARD CLEANOUT DETAIL NTS 9 SCALE: ROOF/EMERGENCY DRAIN DETAIL NTS NTS WATER SUB-METER SCHEMATIC14SCALE: NTS RISER SUPPORT DETAIL RESTRAINED PIPE SWEEP DETAIL SCALE: N.T.S. SCALE: N.T.S. OPEN SIGHT DRAIN DETAIL SCALE: N.T.S. THRUST BLOCK DETAILS SCALE: N.T.S. SCALE: 3 JANITORS CLOSET UNIT WATER HEATER DETAIL NTS 1-1/2" HIGH MIN. SAFETY PAN 1" DRAIN - PIPE TO HUB DRAIN DRAIN VALVE PIPE FULL SIZE TO MOP SINK DIELECTRIC UNION (TYP FOR 2) ASME T & P RELIEF VALVE - 2" x 2" x 1/4" GALVANIZED WALL ANGLE IRON FRAME 3/4" CADMIUM-PLATED ALL THREAD ROD WITH LOCK WASHERS AND DOUBLE NUTS (TYP 4) SOLDER SEAMS WATER-TIGHT OR DRAIN BOX. TEMPERATURE GAUGE GATE VALVE (TYP) HW CW (TYP) CHECK VALVE VACUUM RELIEF THERMAL EXPANSION TANK, 2 GALLON, AMTROL OR EQUAL. MAY USE COMB. BALL/RELIEF VALVE WHERE ALLOWED. 111213 SCALE: WHE-1/WHE-2 HW/CW TO UNIT FIXTURES COLD WATER SUB-METER BY OWNER RISER SHUTOFF VALVE ON FIRST LEVEL 3/4"CW FOR ONE BATH UNIT, 1"CW FOR TWO BATH UNIT (TYP). CW RISER, SEE FLOOR PLANS FOR EXACT LOCATIONS, SEE RISER DIAGRAMS FOR SIZEUNIT SHUT-OFF PROVIDE HEAT TRAPS IF INTEGRAL HEAT TRAPS ARE NOT PROVIDED BY THE MANUFACTURER.CDT&P RELIEF VALVE INDIRECT PIPED FULL SIZE TO HUB DRAIN RESIDENTIAL UNIT WATER HEATER DETAIL NTS PRIMARY CONDENSATE DRAIN WITH TRAP, 3/4" MIN. HVAC UNIT PER 802.3 REQUIREMENTS, PROVIDE FIRE RATED WALL BOX WITH READY ACCESS SNAP ON GRILL FOR CONDENSATE DRAINAGE, T&P RELIEF VALVE AND PAN. PER 607.3 REQUIREMENT, AMTROL ST-5C-DD OR EQUIVALENT THERMAL EXPANSION TANK ELEVATED PLATFORM PER 2018 NCPC WATER HEATER SHALL BE ELEVATED OFF THE FLOOR DRAIN PAN, PROVIDE PER MFR RECOMMENDATION 10 TRAP SEAL DEVICE DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:19:59 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP00.01 Author Checker 2247601 PLUMBING DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV STANDARD NO.VERSION NO. VERSION DATESTANDARD NO.VERSION NO. VERSION DATEBACKFLOW PREVENTIONSTANDARD DETAILS85.3.20161.1CHARLOTTE WATERNO SCALEREDUCED PRESSURE PRINCIPLEASSEMBLY (RP) 3/4" - 2" INDOORREDUCED PRESSURE PRINCIPLEASSEMBLY (RP) 2 1/ 2" - 12" INDOOR91.2 5.3.2016BACKFLOW PREVENTIONSTANDARD DETAILSCHARLOTTE WATERNO SCALETYPICAL LOCATION REQUIREMENT FOR INSIDE INSTALLATION ELEVATION VIEW PLAN VIEW NOTES: TYPICAL LOCATION REQUIREMENT FOR INSIDE INSTALLATION PLAN VIEW ELEVATION VIEW NOTES: ZONING SETBACK PROPERTY LINE PUBLIC WATER MAIN ROAD R/WMETER CLT WATER CLT WATER SEE NOTE #8 & #9 N.T.S. EXTERIOR BUILDING WALL DISCHARGES FROM THE RELIEF VALVE DRAIN PORT. AN AIR GAP DRAIN IS RECOMMENDED TO REDUCE SPLASHING OF MINOR SUPPORT FOR ASSEMBLY SHALL BE DESIGNED BY OWNER AS REQUIRED. ON A CASE BY CASE BASIS. ASSEMBLY IS NOT AVAILABLE OUTSIDE. CLT WATER WILL REVIEW WHERE ADEQUATE SPACE FOR THE BACKFLOW PREVENTION INDOOR INSTALLATION SHALL ONLY BE PERMITTED IN CASESSHUT-OFF VALVE #1 DRAIN FLOW WALLOUTSIDE WALLFLOOR DRAIN BY GRAVITY SHUT-OFF VALVE #2 VALVE #2 CHECKCHECK VALVE #1 12" MIN. 60" MAX. 4" MIN. REDUCED PRESSURE PRINCIPLE ASSEMBLY FLOW 6" MIN. 24" MIN. CLEAR SPACE 4" MIN. REDUCED PRESSURE PRINCIPLE ASSEMBLY VALVE #1 CHECK VALVE #2 SHUT-OFF VALVE #1 SHUT-OFF TYPE K OR L COPPER TUBING OR 1" MIN. GALVANIZED STEEL PIPE FOR MIN. OF 5' ON EACH END OF ASSEMBLY. SEE NOTE #4 SEE TABLE IN SPECIFICATIONS FOR MINIMUM DRAIN SIZES FOR RP INDOOR INSTALLATIONS. VALVE REQUIRED BPA INSIDE OUTSIDE WALLTEST COCK #1 OUTLET SEE NOTE #6 SEE NOTE #5 STRAINERRECOMMENDED TEST COCK #1 PIPE MATERIAL AND FITTINGS SHALL BE AS SPECIFIED IN CLT WATER STANDARDS & SPECIFICATIONS. ALL LOCATIONS FOR BPA'S REQUIRE CLT WATER APPROVAL. ASSEMBLIES SHALL BE INSTALLED UPRIGHT AND IN THE HORIZONTAL POSITION. BACKFLOW PREVENTION ASSEMBLIES (BPA's) SHALL CONFORM TO CLT WATER 1. 2. 3. 4. 5. 6. SPECIFICATIONS. SHUT-OFF VALVES ARE SPECIFIC TO EACH APPROVED 7. BPA AND NO SUBSTITUTIONS OF SHUT-OFF VALVES ARE PERMITTED. REFER TO CLT WATER APPROVED LIST OF BPA's. 8. 9. THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. CONNECTION POINTS, OR OTHER WATER - USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND ITS CLT WATER - REQUIRED BACKFLOW PREVENTER. 11. ALL INSTALLATIONS INTENDED FOR ADDRESSING CLT WATER REQUIREMENTS, REQUIRE PRIOR APPROVAL FROM THE APPROPRIATE CLT WATER BACKFLOW INSPECTOR. 10. EXPECTED BY THE BACKFLOW ASSEMBLY MANUFACTURER. CAPABLE OF HANDLING IN EXCESS OF THE MAXIMUM DISCHARGE RATE INDOOR INSTALLATION OF RP'S SHOULD PROVIDE FOR DRAINAGE BLDG. CODE (TYP.) SLEEVE PER NC SEE NOTE #7 RELIEF LOWEST POINT OR RELIEF VALVE OUTLET EACH CLT WATER-REQUIRED BPA IS REQUIRED TO BE TESTED BY A CLT WATER - APPROVED CERTIFIED TESTER PRIOR TO PLACING THE WATER SYSTEM IN SERVICE. TEST RESULTS SHALL BE SUBMITTED TO CLT WATER WITHIN 30 DAYS AND TESTED ANNUALLY THEREAFTER SUBMITTING RESULTS TO CLT WATER. ZONING SETBACK PROPERTY LINE PUBLIC WATER MAIN ROAD R/WMETER CLT WATER CLT WATER SEE NOTE #9 & #10 N.T.S. SEE NOTE #5 SEE NOTE #3 SHUT-OFF VALVE #1 DUCTILE IRON PIPE OR FLOW CHECK VALVE #2 CHECK VALVE #1 SHUT-OFF VALVE #2 SEE NOTE #3 TYPE K OR L COPPER TUBING FOR MIN. OF 5' ON EACH END OF ASSEMBLY. 6" MIN. 24" MIN. CLEAR SPACE CHECK VALVE #1 CHECK VALVE #2SHUT-OFF VALVE #1 SHUT-OFF VALVE #2 6" MIN. REDUCED PRESSURE PRINCIPLE ASSEMBLY 12" MIN. 60" MAX. EXTERIOR BUILDING WALL WALLOUTSIDE WALLFLOOR REDUCED PRESSURE PRINCIPLE ASSEMBLY FLOW DRAIN 6" MIN. DRAIN VALVE ON DRAIN PORT. SHALL BE SUPPORTED AT EACH VALVE AND SHALL NOT BLOCK RELIEF FIRE LINE INSTALLATIONS SHALL HAVE OUTSIDE STEM AND YOKE (OS&Y) HANDWHEEL OPERATORS OR BUTTERFLY VALVES, AND LISTED ON APPROVED LIST AS FIRE APPROVED. IF SERVING FIRE SPRINKLERS, SUPPORT FOR ASSEMBLY SHALL BE DESIGNED BY OWNER, 8" - 12" RELIEF VALVEOUTLET REQUIRED BPA INSIDE OUTSIDE WALLTEST COCK #1 6" CLEAR OF OBSTRUCTIONS SEE NOTE #6 TEST COCK #1 SEE TABLE IN SPECIFICATIONS FOR MINIMUM DRAIN SIZES FOR RP INDOOR INSTALLATIONS LOWEST POINT OR RELIEF VALVE OUTLET BLDG. CODE (TYP.) SLEEVE PER NC DISCHARGES FROM THE RELIEF VALVE DRAIN PORT. AN AIR GAP DRAIN IS RECOMMENDED TO REDUCE SPLASHING OF MINOR AVAILABLE OUTSIDE. CLT WATER WILL REVIEW ON A CASE BY CASE BASIC. ADEQUATE SPACE FOR THE BACKFLOW PREVENTION ASSEMBLY IS NOT INDOOR INSTALLATION SHALL ONLY BE PERMITTED IN CASES WHERE PIPE MATERIAL AND FITTINGS SHALL BE AS SPECIFIED IN CLT WATER STANDARDS & SPECIFICATIONS. ALL LOCATIONS FOR BPA'S REQUIRE CLT WATER APPROVAL. ASSEMBLIES SHALL BE INSTALLED UPRIGHT AND IN THE HORIZONTAL POSITION. BACKFLOW PREVENTION ASSEMBLIES (BPA's) SHALL CONFORM TO CLT WATER 1. 2. 3. 4. 5. 7. SPECIFICATIONS. SHUT-OFF VALVES ARE SPECIFIC TO EACH APPROVED 8. BPA AND NO SUBSTITUTIONS OF SHUT-OFF VALVES ARE PERMITTED. REFER TO CLT WATER APPROVED LIST OF BPA's. 9. 10. THERE SHALL BE NO TAPS, PIPING BRANCHES, UNAPPROVED BYPASS PIPING, HYDRANTS, FIRE DEPT. CONNECTION POINTS, OR OTHER WATER - USING APPURTENANCES CONNECTED TO THE SUPPLY LINE BETWEEN ANY WATER METER AND ITS CLT WATER - REQUIRED BACKFLOW PREVENTER. 12. ALL INSTALLATIONS INTENDED FOR ADDRESSING CLT WATER REQUIREMENTS, REQUIRE PRIOR APPROVAL FROM THE APPROPRIATE CLT WATER BACKFLOW INSPECTOR. 11. EXPECTED BY THE BACKFLOW ASSEMBLY MANUFACTURER. CAPABLE OF HANDLING IN EXCESS OF THE MAXIMUM DISCHARGE RATE INDOOR INSTALLATION OF RP'S SHOULD PROVIDE FOR DRAINAGE 6. BLDG. CODE (TYP.) SLEEVE PER NC SEE NOTE #7 SEE NOTE #8 TAMPER SWITCHES ARE REQUIRED. WHEN VALVE IS FULLY OPEN EACH CLT WATER-REQUIRED BPA IS REQUIRED TO BE TESTED BY A CLT WATER - APPROVED CERTIFIED TESTER PRIOR TO PLACING THE WATER SYSTEM IN SERVICE. TEST RESULTS SHALL BE SUBMITTED TO CLT WATER WITHIN 30 DAYS AND TESTED ANNUALLY THEREAFTER SUBMITTING RESULTS TO CLT WATER. 6" MIN. W/VACUUM BREAKER WALL THICKNESS 3/4" HOSE CONNECTION 3/4" FEMALE 1" MALE I.P.S 3 1/8" 2" 5 1/2" SQ FLOOR G DRIP LEG EQUIPMENT INSIDE3/4" HB STRAINER (TYPICAL) UNION (TYPICAL) CW SUPPLY SEE PLANS FOR LOCATION & SIZE CW TO BUILDING SEE PLANS FOR LOCATION & SIZE SHOCK ABSORBER SA "C" PRESSURE GAUGE GAS SUPPLY CLAMP SEE PLANS FOR SIZE GAS COCK UNION (TYPICAL) SECURE PIPE WITH GALVANIZED RETAINER GAS REGULATOR 2 PSI INLET 7" W.C. OUTLET FLEXIBLE CONNECTION PROVIDE AN AGA APPROVED 1. BACKFLOW PREVENTER SHALL BE LINE-SIZE. 2. ALL THREADED PIPING SHALL BE BRASS. 3. PROVIDE BACKFLOW PREVENTER BETWEEN DOMESTIC WATER, FIRE PROTECTION AND IRRIGATION PIPING ETC.. 4. DEVICE SHALL MEET ASSE 1013 REQUIREMENTS. NOTES: AIR GAP FITTING (SUPPLIED BY MANUF.) SPILL OVER DRAIN AIR GAP TAPPING) BE FULL SIZE OF (DRAIN LINE SHALL SERVICE VALVE (TYPICAL) SCALE: 6 PRESSURE REDUCING STATION DETAIL NTS BY CHUTE SUPPLIEROPERATION). FINAL CONNECTiION TO ELECTRICAL BY ELECTRICAL LAUNDRY/TRASH CHUTE WASH DOWN DETAIL NOTE: SANITIZING UNIT DISINFECTING & SCHEMATIC OFWATER SUPPLY IS FROM PROVIDE SUB-METER IF TENANT WATER HEATER. PLUMBING FIRE SPRINKLER HEAD AT HIGHEST INTAKE. FLUSHING HEAD AT HIGHEST INTAKE. PROPORTIONING VALVE AT REMOTE LOCATION. D & S UNIT: 1-GAL. CONTAINER, MOUNTING BRACKET & CONTRACTOR. 8. 7. 6. CHUTE SUPPLIER PROVIDED BY TYP. OF 2. COUPLING 3/4" HOT WATER SEE OF HOT WATER SUPPLY. PLANS FOR CONNECTION BY-PASS NORMALLY CLOSED PARTIAL PLAN SANITIZING UNIT DISINFECTING & ISOMETRIC OF INSTALLATION NOTES 6 VDC SOLENOID VALVE (OPTIONAL, NOT NEEDED FOR MANUAL ALL PLUMBING MATERIALS & LABOR BY OTHERS. 1/2" CONDUIT TO SOLENOID VALVE (ABOVE HIGHEST INTAKE) 1/4-TURN GATE VALVE (SHUTOFF & BY-PASS). 3/4" DOMESTIC HOT WATER INLET W/ VACUUM BREAKER. TRASH CHUTE FROM TRASH ROOM. 1.BY PLUMBER5. 4. 2. 3. BACKFLOW PREVENTER WATTS 909QTS-HW 1 2 4 3 6 7 8 1 6 6 TRIPLEX VFD WATER BOOSTER PUMP DETAIL HOUSEKEEPING PAD WITH FINISHED FLOOR SPRING ISOLATION BUILDINGWATER TO PRESSURE GAUGE (0-150 P.S.I.G. TYPICAL) FLEX CONNECTION (TYPICAL) PRESSURE SWITCH VALVED BY-PASS NORMALLY CLOSED BOOSTED COLD NON-SLAMMING CHECK VALVE WATER SUPPLY TO PUMPPRESSURE REGULATING/ NO-SLAM CHECK VALVE BALL VALVE (TYPICAL) COLD WATER PUMP SERVICE VALVE (TYPICAL) SUCTION INLET ISOLATION MOUNTING SKID BASE W/VIBRATION 4" DIA. VARIABLVE DRIVES FREQUENCYLOGIC SECTION CONTROL PANEL WHERE REQUIRED SCALE: N.T.S. * REFER TO PUMP SCHEDULE THIS SHEET FOR PUMP CHARACTERISTIC AND CAPACITIES SEW-75 .75 25 50 3450 STANCOR SCALE: N.T.S. MULTI-PIN CONNECTOR & CORD IN CONDUIT LENGHTS AS REQUIRED, 25 FT. IS STANDARD WITH OPTION OF A 25 FT. IN INCREMENTS. -SP-1 PROVIDE PERFORATED STEEL COVER FOR ELEVATOR PIT. SUBMITTALS CONTRACTOR DRAWINGS. NOTES: 2. SUMP PIT TO BE MINIMUM 24" DEEP. COORDINATE INSTALLATION INSTRUCTIONS AND PER APPROVED 1. COORDINATE ALL WORK WITH MANUFACTURERS 3. BACK FILL AROUND PIT WITH CONCRETE IF PIT INSTALLATION WITH STRUCTURAL AND ELEVATOR 24 HOUR MONITORING OR BUILDING BMS SYSTEM. FIBERGLASS OR STEEL BASIN IS USED CONTACTS. CONTRACTOR SHALL CONNECT THE CONTROL PANEL 4. CONTROL PANEL SHALL BE PROVIDED WITH SPARE WITH REMOTE ALARM LOCATED IN ENGINEERS OFFICE OR TO 5. CONTRACTOR SHALL PROVIDE PUMP AND CONTROLS FOR EACH ELEVATOR PIT. UNLESS INDICATED OTHERWISE ON THE DESIGN DOCUMENTS. LOCATION, FOR INSTALLATION OF CONTROL WIRING. RADIUS BENDS FROM SUMP PIT TO CONTROL PANEL 6. CONTRACTOR SHALL PROVIDE 4" CONDUIT WITH LONG 30"x 30"x 30" DEEPSIZE BASIN - - - PUMP No. H.P. T.D.H. G.P.M. PUMP SCHEDULE - -- - 60 1 115 R.P.M. HERTZ PHASE VOLTS DESIGN BASIS OF ELECTRICAL 4 INCREMENTS AVAILABLECORD IN LENGTHS AS REQUIRED; 25 FT. IS STANDARD, OPTIONAL 25 FT. JUNCTION BOX WILL BE PROVIDED WITH MULTI-PIN CONNECTOR AND ITEMS 1,2,3,4,6,7 & 8 PROVIDED BY STANCOR AS A STANDARD PACKAGE PUMP ON FLOAT8 AS REQUIRED, 25 FT. IS STANDARD, OPTIONAL 25 FT. INCREMENTS.BE PROVIDED WITH MULTI-PIN CONNECTOR & CORD IN LENGTHS JUNCTION BOX WILL MOUNT TO PUMP DISCHARGE PIPING7. HIGH LIQUID ALARM FLOAT WITH CLAMP DEVICE TO LIQUID ALARM CABLE & PUMP ON FLOAT CABLE. 6. OIL MINDER CABLE, POWER CABLE, PROBE CABLE, HIGH PROTECTION TAPE 5. ALL BURIED PUMP PRESSURE DISCHARGE PIPING 1.0 SE-100 SHALL BE PROTECTED WITH TAPECOAT CT CORROSION CONTACT FOR A REMOTE ALARM LOCATION. ALARM BUILT INTO PANEL. PANEL SHALL HAVE ADDITIONAL LIQUID ALARM. PROVIDE SILENCING BUTTON FOR AUDIBLE PUMP DOES NOT RUN DUE TO OIL IN PIT OR HIGH OPTIONAL BUILT IN AUDIBLE AND VISUAL ALARM WHEN 3. STANCOR OIL MINDER 115V, 1∅ CONTROL SYSTEM WITH 2. STANCOR CHECK VALVE ___HP, 115 VOLT, 3600 RPM, 2" DISCHARGE CONNECTION 1. STANCOR MODEL_____________ SUBMERSIBLE EFFLUENT PUMP 4 3 8 COVER 6 MIN. PIT SIZE: 24"X24"X24" GATE VALVE PROBE HIGH LEVEL FLOAT OFF PUMP ON FLOAT 7 5 2 1 FLOOR 8 PIN MALE CONNECTOR FLOATHIGH ALARMFLOATON15131075 107531 10 AMPS @ 240 VACRMS RELAY F4F3F2F1PROBEOILP2(L)P1(N)115 VACNL1 MADE IN USAPUMP RUN SILENCE RESETPATENTS:4,752,188; 4,715,785; 6,203,281OIL MINDER CONTROL AMPSOVERLOADSETTINGSSENSORS OVERLOADHIGH LEVELOIL FAULTPOWER WWW.STANCORPUMPS.COMMONROE, CT 06468515 FAN HILL RD. UL 508 LISTED NEMA 4X 8 PIN FEMALE CONNECTOR POWERPUMP JUNCTION BOX RMSPOWER IN ELEVATOR PIT SUMP PUMP DETAIL (EXPOSED TYPE) NON-FREEZE WALL HYDRANT DETAIL SCALE: N.T.S. - SCALE: N.T.S. GAS PIPE CONNECTION DETAIL 23 SCALE: N.T.S. SEW-150 1.5 25 100 3450 STANCOR SP-2 60 1 115 1 5 4 BACKFLOW PREVENTION DEVICE (REDUCED PRESSURE ZONE) DETAIL STRAINER (TYPICAL) UNION SCALE:NTS7 NC ESOLCNPOEESOEPOLCN CHALOT T ETERWWWRHA CITY OF CHARLOTTE DEPARTMENTCHALOT T ETERWWWRHA CITY OF CHARLOTTE DEPARTMENTDRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:19:59 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP00.02 Author Checker 2247601 PLUMBING DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV WMB HD W/BWV WMB WMB HD W/BWV HD W/BWV WMB HD W/BWV WMB HD W/BWV 2" 2 " WC 3" 3" 1ST 2" 2" 2" 3- BATHROOM GROUPS 15 DFU 3- BATHROOM GROUPS 15 DFU3- BATHROOM GROUPS 18 DFU 3" 3" 3" 3" 3" EXPANSION FITTING 2" DW DISPOSAL2" LAV WC LAV WCTUB TUB TUB KS NOT TO SCALE TYPICAL BATHROOM GROUP RISERS NOT TO SCALE KITCHEN SINK RISERS NOT TO SCALE WASHING MACHINE \ HUB DRAIN RISERS TYPICAL THREE LEVEL RISERS S 1 2" 2 " LAV 2" WC 3" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WCTUB TUB TUB S 1A LAV 2" LAV LAV LAV LAV S 1B 2" 2 "WC 3" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC LAV WC SHOWER 2" 2 "LAV SHOWER SHOWER 3- BATHROOM GROUPS 18 DFUS 1C 2" WC 3" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WC LAV 2" LAV LAV LAV LAV SHOWER SHOWER SHOWER S 2 3- KITCHEN SINKS W/DISPOSAL 6 DFU 2" WCO WCO WCO WCO WCO EXPANSION FITTING 2" DW DISPOSAL KS 2" DW DISPOSAL KS S 3 3- PRIVATE CLOTHES WASHERS 6 DFU 2" EXPANSION FITTING 3" 3" 2" 2" 2" S 4 EXPANSION FITTING 3- HUB DRAINS - 6 DFU 2" 2" 3- KITCHEN ISLAND SINKS W/DISPOSAL 6 DFUS 2A WCO WCO 2" 2" WCO EXPANSION FITTING KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV 2ND 3RD 1ST 2ND 3RD 1ST 2ND 3RD 1ST 2ND 3RD 1ST 2ND 3RD 1ST 2ND 3RD 1ST 2ND 3RD 1ST 2ND 3RD 2"VTR 2"VTR 3"VTR 2"VTR3"VTR 3"VTR 3"VTR 3"VTR 3"3"3"3" 2" 2 " WC 3" 3" 1ST 2" 2" 2- BATHROOM GROUPS 10 DFU 2- BATHROOM GROUPS 10 DFU2- BATHROOM GROUPS 12 DFU 3" 3" 3" 3" EXPANSION FITTING 2" DW DISPOSAL2" LAV WC LAVTUB TUB KS NOT TO SCALE TYPICAL BATHROOM GROUP RISERS NOT TO SCALE KITCHEN SINK RISERS NOT TO SCALE WASHING MACHINE \ HUB DRAIN RISERS TYPICAL TWO LEVEL RISERS S 1 2" WC 3" 3" 2" 2" 3" 3" 3" 3" EXPANSION FITTING LAV WCTUB TUB S 1A LAV LAV LAV S 1B 2" 2 "WC 3" 3" 2" 2" 3" 3" 3" 3" EXPANSION FITTING LAV WC LAV SHOWER SHOWER 2- BATHROOM GROUPS 12 DFUS 1C 2" WC 3" 3" 2" 2" 3" 3" 3" 3" EXPANSION FITTING LAV WC LAV LAV LAV SHOWER SHOWER S 2 2- KITCHEN SINKS W/DISPOSAL 4 DFU 2" WCO WCO WCO WCO WCO EXPANSION FITTING 2" DW DISPOSAL KS S 3 2- PRIVATE CLOTHES WASHERS 4 DFU 2" EXPANSION FITTING 3" 3" 2" 2" S 4 EXPANSION FITTING 2- HUB DRAINS - 4 DFU 2" 2" 2- KITCHEN ISLAND SINKS W/DISPOSAL 4 DFUS 2A WCO WCO 2" 2" WCO EXPANSION FITTING KS DISPOSAL DW AAV KS DISPOSAL DW AAV 2ND 1ST 2ND 1ST 2ND 1ST 2ND 1ST 2ND 1ST 2ND 1ST 2ND 1ST 2ND 2"VTR 2"VTR 3"VTR 2"VTR3"VTR 3"VTR 3"VTR 3"VTR 3"3"3"3" 2" 3/4" DOMESTIC WATER RISERS SCALE: N.T.S. SEE WATER SUB-METER SCHEMATIC ON SHEET P0.03. TYPICAL. WATER METER DETAIL KEY NOTES: 1 2" 1-1/2" 1" GAS RISER KEY NOTES: 1-1/2" 1-1/2" 1-1/4" 3/4" 2" 2" 2" 1-1/2" 1-1/2" W 1 W 2 1 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1" 1" 1" 1" 1" 1" 2" 1 TYPICAL GAS RISER SCALE: N.T.S. 1" G 1 2.0 PSI GAS SERVICE FROM METER 1 1" PROVIDESHUT-OFF VALVE AND MAXITROL VENTLESS REGULATOR - SET AT 7"W.C. 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1 2 "2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " GENERAL NOTE FOR THIS SHEET 1. PROVIDE STACK SIZING IN ACCORDANCE WITH SECTION 904.1 OF THE 2018 NORTH CAROLINA PLUMBING CODE. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:19:59 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP00.03 Author Checker 2247601 RISER DIAGRAMS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV WMB HD W/BWV WMB WMB WMB WMB HD W/BWV HD W/BWV HD W/BWV HD W/BWV WMB HD W/BWV WMB WMB WMB HD W/BWV HD W/BWV HD W/BWV 2" 2 " WC 4" 3" 1ST 2" 2" 2" 5- BATHROOM GROUPS 25 DFU 5- BATHROOM GROUPS 25 DFU5- BATHROOM GROUPS 30 DFU 3" 3" 3" 3" 3" EXPANSION FITTING 2" DW DISPOSAL 2" LAV WC LAV WCTUB TUB TUB KS NOT TO SCALE TYPICAL BATHROOM GROUP RISERS NOT TO SCALE KITCHEN SINK RISERS NOT TO SCALE WASHING MACHINE \ HUB DRAIN RISERS TYPICAL FIVE LEVEL RISERS S 1 3" EXPANSION FITTING 2" 2 " LAV 2" 2 " LAV 2" 2 " LAV 2" 3"WCTUB 2" 3"WCTUB 2" WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WCTUB TUB TUB 3" EXPANSION FITTING 2" 2" 2" 3"WCTUB 2" 3"WCTUB S 1A LAV 2" LAV LAV LAV LAV LAV LAV LAV LAV S 1B 2" 2 "WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC LAV WC SHOWER 3" EXPANSION FITTING 2" 2 "LAV 2" 2 "LAV 2" 2 "LAV 2" 3"WC 2" 3"WC SHOWER SHOWER SHOWER SHOWER 5- BATHROOM GROUPS 30 DFUS 1C 2" WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WC 3" EXPANSION FITTING 2" 2" 2" 3"WC 2" 3"WC LAV 2" LAV LAV LAV LAV LAV LAV LAV LAV SHOWER SHOWER SHOWER SHOWER SHOWER S 2 5- KITCHEN SINKS W/DISPOSAL 10 DFU 3" WCO WCO WCO WCO WCO EXPANSION FITTING EXPANSION FITTING 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" S 3 5- PRIVATE CLOTHES WASHERS 10 DFU 2" EXPANSION FITTING EXPANSION FITTING 3" 3" 3" 2" 2" 2" 2" 2" 2" S 4 EXPANSION FITTING EXPANSION FITTING 5- HUB DRAINS - 10 DFU 3" 2" 2" 5- KITCHEN ISLAND SINKS W/DISPOSAL 10 DFUS 2A WCO WCO 3" 2" WCO EXPANSION FITTING EXPANSION FITTING 2" KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV 2ND 3RD 4TH 5TH 1ST 2ND 3RD 4TH 5TH 1ST 2ND 3RD 4TH 5TH 1ST 2ND 3RD 4TH 5TH 1ST 2ND 3RD 4TH 5TH 1ST 2ND 3RD 4TH 5TH 1ST 2ND 3RD 4TH 5TH 1ST 2ND 3RD 4TH 5TH 3"VTR 3"VTR 3"VTR 3"VTR 2"VTR 2"VTR 3"VTR 2"VTR 3"3"3"3" 3"3"3"3" 2" 2 " WC 4" 3" 1ST 2" 2" 2" 4- BATHROOM GROUPS 20 DFU 4- BATHROOM GROUPS 20 DFU4- BATHROOM GROUPS 24 DFU 3" 3" 3" 3" 3" EXPANSION FITTING 2" DW DISPOSAL 2" LAV WC LAV WCTUB TUB TUB KS NOT TO SCALE TYPICAL BATHROOM GROUP RISERS NOT TO SCALE KITCHEN SINK RISERS NOT TO SCALE WASHING MACHINE \ HUB DRAIN RISERS TYPICAL FOUR LEVEL RISERS S 1 EXPANSION FITTING 2" 2 " LAV 2" 2 " LAV 2" 3"WCTUB 2" WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WCTUB TUB TUB EXPANSION FITTING 2" 2" 3"WCTUB S 1A LAV 2" LAV LAV LAV LAV LAV LAV S 1B 2" 2 "WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC LAV WC SHOWER EXPANSION FITTING 2" 2 "LAV 2" 2 "LAV 2" 3"WC SHOWER SHOWER SHOWER 4- BATHROOM GROUPS 24 DFUS 1C 2" WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WC EXPANSION FITTING 2" 2" 3"WC LAV 2" LAV LAV LAV LAV LAV LAV SHOWER SHOWER SHOWER SHOWER S 2 4- KITCHEN SINKS W/DISPOSAL 8 DFU 3" WCO WCO WCO WCO WCO EXPANSION FITTING EXPANSION FITTING 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS S 3 4- PRIVATE CLOTHES WASHERS 8 DFU 2" EXPANSION FITTING EXPANSION FITTING 3" 3" 2" 2" 2" 2" S 4 EXPANSION FITTING EXPANSION FITTING 4- HUB DRAINS - 8 DFU 3" 2" 4- KITCHEN ISLAND SINKS W/DISPOSAL 8 DFUS 2A WCO WCO 3" 2" WCO EXPANSION FITTING EXPANSION FITTING KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV 2ND 3RD 4TH 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH 1ST 2ND 3RD 4TH 2"VTR 2"VTR 3"VTR 2"VTR3"VTR 3"VTR 3"VTR 3"VTR 3"3"3"2" 4"4"4"4" 4"4"4"4" 3"3" 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 3"3"3" 3" 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " 2 " GENERAL NOTES FOR THIS SHEET 1. OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE SHALL BE IN ACCORDANCE WITH SECTION 711 OF THE 2018 NORTH CAROLINA PLUMBING CODE. THE PORTION OF THE STACK BELOW THE OFFSET SHALL BE SIZED AS FOR THE OFFSET OR BASED ON THE TOTAL NUMBER OF DRAINAGE FIXTURE UNITS ON THE ENTIRE STACK, WHICHEVER IS LARGER. OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF LESS THAN FIVE STORIES SHALL BE SIZED AS A BUILDING DRAIN AND IN ACCORDANCE WITH TABLE 710.1(1) OF THE 2018 NORTH CAROLINA PLUMBING CODE. THE PORTION OF THE STACK BELOW THE OFFSET SHALL BE SIZED AS FOR THE OFFSET OR BASED ON THE TOTAL NUMBER OF DRAINAGE FIXTURE UNITS ON THE ENTIRE STACK, WHICHEVER IS LARGER. 2. PROVIDE STACK VENT SIZING IN ACCORDANCE WITH TABLE 904.1 OF THE 2018 NORTH CAROLINA PLUMBING CODE. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:19:59 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP00.04 Author Checker 2247601 RISER DIAGRAMS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV WMB HD W/BWV WMB WMB WMB WMB WMB HD W/BWV HD W/BWV HD W/BWV HD W/BWV HD W/BWV 2" 2 "WC 4" 3" 1ST 2" 2" 2" 6- BATHROOM GROUPS 30 DFU 6- BATHROOM GROUPS 30 DFU6- BATHROOM GROUPS 36 DFU 3" 3" 3" 3" 3" EXPANSION FITTING 2" DW DISPOSAL 2" LAV WC LAV WCTUB TUB TUB KS NOT TO SCALE TYPICAL BATHROOM GROUP RISERS NOT TO SCALE KITCHEN SINK RISERS NOT TO SCALE WASHING MACHINE \ HUB DRAIN RISERS TYPICAL SIX LEVEL RISERS S 1 3" EXPANSION FITTING EXPANSION FITTING 2" 2 "LAV 2" 2 "LAV 2" 2 "LAV 2" 2 "LAV 2" 3"WCTUB 2" 3"WCTUB 2" 3"WCTUB 2" WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WCTUB TUB TUB 3" EXPANSION FITTING EXPANSION FITTING 2" 2" 2" 2" 3"WCTUB 2" 3"WCTUB 2" 3"WCTUB S 1A LAV 2" LAV LAV LAV LAV LAV LAV LAV LAV LAV LAV S 1B 2" 2 "WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC LAV WC SHOWER 3" EXPANSION FITTING EXPANSION FITTING 2" 2 "LAV 2" 2 "LAV 2" 2 "LAV 2" 2 "LAV 2" 3"WC 2" 3"WC 2" 3"WC SHOWER SHOWER SHOWER SHOWER SHOWER 6- BATHROOM GROUPS 36 DFUS 1C 2" WC 4" 3" 2" 2" 2" 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WC 3" EXPANSION FITTING EXPANSION FITTING 2" 2" 2" 2" 3"WC 2" 3"WC 2" 3"WC LAV 2" LAV LAV LAV LAV LAV LAV LAV LAV LAV LAV SHOWER SHOWER SHOWER SHOWER SHOWER SHOWER S 2 6- KITCHEN SINKS W/DISPOSAL 12 DFU 3" WCO WCO WCO WCO WCO EXPANSION FITTING EXPANSION FITTING EXPANSION FITTING 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" S 3 6- PRIVATE CLOTHES WASHERS 12 DFU 2" EXPANSION FITTING EXPANSION FITTING EXPANSION FITTING 3" 3" 3" 2" 2" 2" 2" 2" 2" 2" S 4 EXPANSION FITTING EXPANSION FITTING EXPANSION FITTING 6- HUB DRAINS - 12 DFU 3" 2" 2" 6- KITCHEN ISLAND SINKS W/DISPOSAL 12 DFUS 2A WCO WCO 3" 2" WCO EXPANSION FITTING EXPANSION FITTING EXPANSION FITTING 2" KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL AAV 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 3" 3"VTR 3" 3"VTR 3" 3"VTR 3" 3"VTR 3" 3"3"3" 2"VTR 2"VTR 3"VTR DW 2"VTR 4"4"4"4" 2 "2 "2 "2 "2 "2 "2 "2 "2 "2 "3"3" 2 "2 " 2 " 2 " 2 " 2 " 3" GENERAL NOTES FOR THIS SHEET 1. OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE SHALL BE IN ACCORDANCE WITH SECTION 711 OF THE 2018 NORTH CAROLINA PLUMBING CODE. THE PORTION OF THE STACK BELOW THE OFFSET SHALL BE SIZED AS FOR THE OFFSET OR BASED ON THE TOTAL NUMBER OF DRAINAGE FIXTURE UNITS ON THE ENTIRE STACK, WHICHEVER IS LARGER. OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF LESS THAN FIVE STORIES SHALL BE SIZED AS A BUILDING DRAIN AND IN ACCORDANCE WITH TABLE 710.1(1) OF THE 2018 NORTH CAROLINA PLUMBING CODE. THE PORTION OF THE STACK BELOW THE OFFSET SHALL BE SIZED AS FOR THE OFFSET OR BASED ON THE TOTAL NUMBER OF DRAINAGE FIXTURE UNITS ON THE ENTIRE STACK, WHICHEVER IS LARGER. 2. PROVIDE STACK VENT SIZING IN ACCORDANCE WITH TABLE 904.1 OF THE 2018 NORTH CAROLINA PLUMBING CODE. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:00 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP00.05 Author Checker 2247601 RISER DIAGRAMS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV WMB HD W/BWV WMB WMB WMB WMB WMB WMB HD HD W/BWV HD W/BWV HD W/BWV HD W/BWV HD W/BWV HD W/BWV WMB HD W/BWV 2" 2 " WC 4" 3" 1ST 2" 2" 2" 3"VTR 8- BATHROOM GROUPS 40 DFU 8- BATHROOM GROUPS 40 DFU8- BATHROOM GROUPS 48 DFU 3" 3" 3" 3" 3" EXPANSION FITTING 2" DW DISPOSAL 2" 2"VTR LAV WC LAV WCTUB TUB TUB KS NOT TO SCALE TYPICAL BATHROOM GROUP RISERS NOT TO SCALE KITCHEN SINK RISERS NOT TO SCALE WASHING MACHINE \ HUB DRAIN RISERS TYPICAL EIGHT LEVEL RISERS S 1 3" 3" EXPANSION FITTING EXPANSION FITTING 2" 2 " LAV 2" 2 " LAV 2" 2 " LAV 2" 2 " LAV 2" 2 " LAV 3" 2" 3"WCTUB 2" 3"WCTUB 2" 3"WCTUB 2" 3"WCTUB 3" 2" WC 4" 3" 2" 2" 2" 3"VTR 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WCTUB TUB TUB 3" 3" EXPANSION FITTING EXPANSION FITTING 2" 2" 2" 2" 3" 2" 3"WCTUB 2" 3"WCTUB 2" 3"WCTUB 2" 3"WCTUB 3" S 1A LAV 2" LAV LAV LAV LAV LAV LAV LAV LAV LAV LAV LAV LAV S 1B 2" 2 "WC 4" 3" 2" 2" 2" 3"VTR 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC LAV WC SHOWER 3" 3" EXPANSION FITTING EXPANSION FITTING 2" 2 "LAV 2" 2 "LAV 2" 2 "LAV 2" 2 "LAV 2" 2 "LAV 3" 2" 3"WC 2" 3"WC 2" 3"WC 2" 3"WC 3" SHOWER SHOWER SHOWER SHOWER SHOWER SHOWER 8- BATHROOM GROUPS 48 DFUS 1C 2" WC 4" 3" 2" 2" 2" 3"VTR 3" 3" 3" 3" 3" EXPANSION FITTING LAV WC WC 3" 3" EXPANSION FITTING EXPANSION FITTING 2" 2" 2" 2" 3" 2" 3"WC 2" 3"WC 2" 3"WC 2" 3"WC 3" LAV 2" LAV LAV LAV LAV LAV LAV LAV LAV LAV LAV LAV LAV SHOWER SHOWER SHOWER SHOWER SHOWER SHOWER SHOWER S 2 8- KITCHEN SINKS W/DISPOSAL 16 DFU 3" WCO WCO WCO WCO WCO EXPANSION FITTING EXPANSION FITTING EXPANSION FITTING 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" DW DISPOSAL KS 2" 2" S 3 8- PRIVATE CLOTHES WASHERS 16 DFU 2" EXPANSION FITTING EXPANSION FITTING EXPANSION FITTING 3" 3" 3" 2" 3" 2" 2" 2" 2" 2" 2" 2" S 4 EXPANSION FITTING EXPANSION FITTING EXPANSION FITTING 8- HUB DRAINS - 16 DFU 3" 2" 2" 2" 3"VTR 2"VTR 8- KITCHEN ISLAND SINKS W/DISPOSAL 16 DFUS 2A WCO WCO 3" 2" WCO EXPANSION FITTING EXPANSION FITTING EXPANSION FITTING 2" 2" KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV KS DISPOSAL DW AAV 2"VTR 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 1ST 2ND 3RD 4TH 5TH 6TH 8TH 4"4"4"4" 2 "2 "2 "2 "2 "2 "2 " 2 " 2 " 2 " 2 " 2 " 3"3" 2 " 2 "2 "2 "2 "2 "2 "3" 2" DW DISPOSAL KS 2" DW DISPOSAL KS EXPANSION FITTING 2" 2 " LAV 2" 3"WCTUB EXPANSION FITTING 2" 2" 3"WCTUB LAV LAV EXPANSION FITTING 2" 2 "LAV 2" 3"WC SHOWER EXPANSION FITTING 2" 2" 3"WC LAV LAV SHOWER 2 "2 " 2" KS DISPOSAL DW AAV 2 "2" 7TH 8TH 7TH 8TH 7TH 8TH 7TH 8TH 7TH 8TH 7TH 8TH 7TH 8TH 7TH GENERAL NOTE FOR THIS SHEET OFFSETS IN DRAINAGE PIPING IN BUILDINGS OF FIVE STORIES OR MORE SHALL BE IN ACCORDANCE WITH SECTION 711 OF THE APPLICABLE PLUMBING CODE. THE PORTION OF THE STACK BELOW THE OFFSET SHALL BE SIZED AS FOR THE OFFSET OR BASED ON THE TOTAL NUMBER OF DRAINAGE FIXTURE UNITS ON THE ENTIRE STACK, WHICHEVER IS LARGER. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:00 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP00.06 Author Checker 2247601 RISER DIAGRAMS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV C D E F G H J K L M N P Q R 4 U 7 6 5 1 2 S 9 10 11 13 14 16 17 8 3 TB OV XY 15 12 TERMINATE (8") SANITARY APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. SLOPE PIPING AT (ADD SLOPE) FALL PER FOOT. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:00 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP01.01 Author Checker 2247601 LEVEL 1 - UNDERFLOOR - SITE PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1" = 20'-0" UNDERFLOOR PLUMBING SITE PLAN1 C D E F G H J K L M N P Q R 4 U 7 6 5 1 2 S 9 10 11 13 14 16 17 8 3 TB OV XY 15 12 TERMINATE (10") SANITARY APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. SLOPE PIPING AT (ADD SLOPE) FALL PER FOOT. TERMINATE (8") FIRE MAIN APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. TERMINATE (6") DOMESTIC WATER APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. TERMINATE (2") IRRIGATION SERVICE APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:04 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP01.03 Author Checker 2247601 LEVEL 3 - FLOOR PLAN - SITE PLAN SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1" = 20'-0" LEVEL 3 PLUMBING SITE PLAN1 C D 9 10 11 13 14 16 17 8 B 15 12 STAIR 2 824 RETAIL 973 RETAIL 973 RETAIL 812 RETAIL 330 TRASH 967 RETAIL 974 RETAIL 974 TERMINATE (8") SANITARY APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. SLOPE PIPING AT (ADD SLOPE) FALL PER FOOT. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:05 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.01C-UF Author Checker 2247601 LEVEL 1 - UNDER FLOOR -AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 1 -UNDER FLOOR -AREA C1 K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T CIRCULATION 1317 ELEVATOR 3 340 STAIR 5 1176 GARAGE 320 2 S8 3 S84 S8 2 S83 S8 1A S8 1 S8 4 S8 1A S8 2 S8 3 S8 4 S8 1A S8 2 S8 3 S8 4 S8 1A S8 2 S8 3 S8 4 S8 3 S3 4 S3 1 W3 1 S3 1 S3 3 S3 3 S3 1 S3 2 S3 3 S3 4 S3 1 S3 2 S3 1 S3 3 S3 4 S3 1 S3 2 S3 3 S3 4 S3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:09 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.02A Author Checker 2247601 LEVEL 2 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA A1 C D E F G H J 4 7 6 5 1 2 8 3 B OV XY CIRCULATION 643 STAIR 2 800 ELEVATOR 1 1344 ELEVATOR 2 1343 GARAGE 320 1 S6 2 S8 4 S8 3 S8 1 S8 2 S3 3 S3 4 S3 2 S3 3 S3 4 S3 2 S3 3 S3 4 S3 1 S3 2 S3 3 S3 4 S3 1 S3 1 S3 2 S3 3 S3 4 S3 1 S3 1 S3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:13 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.02B Author Checker 2247601 LEVEL 2 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA B1 C D 9 10 11 13 14 16 17 8 B 15 12 TRASH 959 STAIR 1 1204 CIRCULATION 643 STAIR 2 800 1C S6 1 S6 2 S6 1 S6 1C S6 3 S6 4 S6 2 S6 1 S6 1C S6 3 S6 4 S6 2 S6 1 S6 1C S6 3 S6 4 S6 2 S6 1 S6 1C S6 3 S6 4 S6 2 S6 3 S6 4 S6 1A S6 2 S6 3 S6 2 S6 4 S6 1C S6 4 S6 3 S6 1A S6 1C S6 2 S6 3 S6 4 S6 1 S6 4 S6 1 S6 3 S6 2 S6 1C S6 4 S6 1 S6 3 S6 2 S6 1C S6 4 S6 1 S6 3 S6 2 S6 1C S 1 S6 3 S64 S6 2 S6 1C S6 2 S64 S6 3 S6 1C S6 2 S63 S6 4 S6 2 S6 3 S6 4 S6 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:17 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.02C Author Checker 2247601 LEVEL 2 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA C1 K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T 2 S8 3 S84 S8 1 W8 2 S83 S8 1A S8 1 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 3 S3 4 S3 1 W3 1 S3 1 W3 1 S3 3 S3 3 S3 1 S3 2 S3 3 S3 4 S3 1 W3 1 S3 2 S3 1 W3 1 S3 3 S3 4 S3 1 W3 1 S3 2 S3 3 S3 4 S3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:23 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.03A Author Checker 2247601 LEVEL 3 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA A1 C D E F G H J 4 7 6 5 1 2 8 3 B OV XY FIRE COMMAND 1239 PUMP ROOM 326 ELEC ROOM 692 CIRCULATION 927 RESIDENTIAL STORAGE 691 TELECOM 832 TELECOM 899 GARAGE 873 STAIR 2 804 TERMINATE (10") SANITARY APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. SLOPE PIPING AT (ADD SLOPE) FALL PER FOOT. TERMINATE (8") FIRE MAIN APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. TERMINATE (6") DOMESTIC WATER APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. TERMINATE (2") IRRIGATION SERVICE APPROXIMATELY 5’-0” FROM OUTSIDE OF BUILDING. SEE CIVIL SITE UTILITY PLAN FOR CONTINUATION. FINISH FLOOR ELEVATION: (FFE)’. INVERT AT CIVIL CONNECTION: (INVERT)’ +/-. COORDINATE EXACT LOCATION, SIZE AND INVERT OF CIVIL CONNECTION PRIOR TO CONSTRUCTION. 1 S6 2 S8 4 S8 1 W8 3 S8 1 S8 2 S3 3 S3 4 S3 2 S3 3 S3 4 S3 2 W3 2 S3 3 S3 4 S3 1 W3 1 S3 2 S3 3 S3 4 S3 2 W3 1 S3 1 S3 2 S3 3 S3 4 S3 2 W3 1 S3 1 S3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:28 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.03B Author Checker 2247601 LEVEL 3 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA B1 C D 9 10 11 13 14 16 17 8 B 15 12 STAIR 2 804 1C S6 1 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 3 S6 1 W6 4 S6 1A S6 2 S6 3 S6 2 S6 1 W6 4 S6 1C S6 1 W6 4 S6 3 S6 1A S6 1C S6 2 S6 3 S6 4 S6 2 W6 1 S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S 1 S6 3 S64 S6 1 W6 2 S6 1C S6 2 S64 S6 3 S6 1 W6 1C S6 2 S63 S6 1 W6 4 S6 2 S6 3 S6 2 W6 4 S6 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:34 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.03C Author Checker 2247601 LEVEL 3 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA C1 K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T ELEVATOR 3 343 BOH 1441 STAIR 5 1178 2 S8 3 S84 S8 1 W8 2 S83 S8 1A S8 1 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 3 S3 4 S3 1 W3 1 S3 1 W3 1 S3 3 S3 3 S3 1 S3 2 S3 3 S3 4 S3 1 W3 1 S3 2 S3 1 W3 1 S3 3 S3 4 S3 1 W3 1 S3 2 S3 3 S3 4 S3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:40 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.04A Author Checker 2247601 LEVEL 4 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA A1 C D E F G H J 4 7 6 5 1 2 8 3 B OV XY LOADING 321 BOH 1430 CIRCULATION 1320 RESIDENTIAL STORAGE 874 BOH 1434 GARAGE 318 2 S6 3 S6 1 S6 2 S8 4 S8 1 W8 3 S8 1 S8 2 S3 3 S3 4 S3 2 S3 3 S3 4 S3 2 W3 2 S3 3 S3 4 S3 1 W3 1 S3 2 S3 3 S3 4 S3 2 W3 1 S3 1 S3 2 S3 3 S3 4 S3 2 W3 1 S3 1 S3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:46 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.04B Author Checker 2247601 LEVEL 4 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA B1 C D 9 10 11 13 14 16 17 8 B 15 12 STAIR 1 1206 2 S6 1 S6 1C S6 3 S6 1C S6 1 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 3 S6 1 W6 4 S6 1A S6 2 S6 3 S6 2 S6 1 W6 4 S6 1C S6 1 W6 4 S6 3 S6 1A S6 1C S6 2 S6 3 S6 4 S6 2 W6 1 S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S 1 S6 3 S64 S6 1 W6 2 S6 1C S6 2 S64 S6 3 S6 1 W6 1C S6 2 S63 S6 1 W6 4 S6 2 S6 3 S6 2 W6 4 S6 4 S6 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:20:52 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.04C Author Checker 2247601 LEVEL 4 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA C1 4 U 7 6 5 1 2 8 3 2 S5 4 S5 3 S5 2 S5 1A S5 4 S5 3 S5 1 S5 1A S5 3 S5 2 S5 4 S5 2 S5 1A S5 3 S5 4 S5 2 S5 3 S5 4 S5 1A S5 1A S5 1 S5 2 S5 3 S5 4 S5 4 S5 1C S5 3 S5 4 S5 2 S5 2 S5 3 S5 4 S5 1A S5 1 S5 4 S5 2 S5 1C S5 3 S5 3 S5 4 S5 2 S5 1 S5 1C S5 2 S5 3 S5 4 S5 1 S5 2 S5 3 S5 4 S5 1 S5 1A S5 4 S5 3 S5 2 S5 1 S5 1 S5 4 S5 2 S5 3 S5 1C S51C S5 3 S5 2 S5 1 S5 4 S5 1 S5 2 S5 3 S5 4 S5 1A S5 1A S5 3 S5 4 S5 2 S5 2 S5 3 S54 S5 1A S5 2 S5 3 S5 4 S5 1C S5 2 S8 3 S84 S8 1 W8 2 S83 S8 1A S8 1 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1 S5 4 S5 2 S5 3 S5 1A S5 1A S5 4 S5 3 S5 2 S51 S5 1A S5 2 S5 3 S3 4 S3 1 W3 1 S3 1 W3 1 S3 3 S3 3 S3 1 S3 2 S3 3 S3 4 S3 1 W3 1 S3 2 S3 1 W3 1 S3 3 S3 4 S3 1 W3 1 S3 2 S3 3 S3 4 S3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:21:01 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.05A Author Checker 2247601 LEVEL 5 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA A1 4 7 6 5 1 2 8 3 BOH 568 2 S6 3 S6 2 W6 1 S6 4 S5 1 S5 2 S5 3 S5 1C S5 1C S5 4 S5 3 S5 1 S5 2 S5 4 S5 3 S5 2 S5 1A S5 2 S5 3 S5 4 S5 1A S5 1A S5 3 S5 4 S5 2 S5 2 S5 4 S5 3 S5 1A S5 1A S5 4 S5 3 S5 2 S5 1 S5 1A S5 3 S5 4 S5 1 S53 S5 2 S5 4 S5 1C S5 2 S5 1A S5 2 S5 3 S5 4 S5 2 S5 3 S5 4 S5 1 S5 2 S5 4 S5 3 S5 1 S5 2 S54 S5 3 S5 1 S5 2 S5 1A S5 4 S5 3 S52 S5 1A S5 4 S5 3 S5 2 S5 1A S5 4 S5 3 S5 2 S51 S52 S5 3 S5 4 S5 1A S5 1A S5 3 S54 S5 2 S4 4 S5 2 S53 S5 1C S5 1 S54 S5 3 S5 2 S5 2 S8 4 S8 1 W8 3 S8 1 S8 1A S4 2 S3 3 S3 4 S3 2 S3 3 S3 4 S3 2 W3 2 S3 3 S3 4 S3 1 W3 1 S3 2 S3 3 S3 4 S3 2 W3 1 S3 1 S3 2 S3 3 S3 4 S3 2 W3 1 S3 1 S3 1 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:21:12 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.05B Author Checker 2247601 LEVEL 5 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA B1 9 10 11 13 14 16 17 8 15 12 UNIT B2.1 427 STAIR 1 1207 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 1C S6 1 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 3 S6 1 W6 4 S6 1A S6 2 S6 3 S6 2 S6 1 W6 4 S6 1C S6 1 W6 4 S6 3 S6 1A S6 1C S6 2 S6 3 S6 4 S6 2 W6 1 S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S 1 S6 3 S64 S6 1 W6 2 S6 1C S6 2 S64 S6 3 S6 1 W6 1C S6 2 S63 S6 1 W6 4 S6 2 S6 3 S6 2 W6 4 S6 1 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:21:22 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.05C Author Checker 2247601 LEVEL 5 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA C1 2 S5 4 S51 W5 3 S5 2 S5 1A S5 2 W5 4 S5 3 S5 1 S5 1A S5 3 S5 2 S5 4 S5 1 W5 2 S5 1A S5 3 S5 4 S5 1 W5 2 S5 3 S5 4 S5 1 W5 1A S5 1A S5 1 S5 2 S5 3 S5 4 S5 2 W5 4 S5 1C S5 3 S5 4 S5 1 W5 2 S5 2 S5 3 S5 4 S5 1 W5 1A S5 1 S5 4 S5 2 W5 2 W5 2 S5 1C S5 3 S5 3 S5 4 S5 2 S5 1 S5 1C S5 2 S5 3 S5 4 S5 1 W5 1 S5 2 S5 3 S5 4 S5 1 W5 1 S5 1A S5 1 W5 4 S5 3 S5 2 S5 1 S5 1 S5 4 S5 1 W5 2 S5 3 S5 1C S51C S5 3 S5 2 S5 1 S5 4 S5 1 W5 1 S5 2 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S5 4 S5 1 W5 2 S5 2 S5 3 S54 S5 1 W5 1A S5 2 S5 3 S5 4 S5 1 W5 1C S5 2 S8 3 S84 S8 1 W8 2 S83 S8 1A S8 1 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1 S5 4 S5 2 W5 2 S5 3 S5 1A S5 1A S5 2 W5 4 S5 3 S5 2 S51 S5 1A S5 2 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:21:36 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.06A Author Checker 2247601 LEVEL 6 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA A1 2 S6 3 S6 2 W6 1 S6 2 W5 4 S5 1 S5 2 S5 3 S5 1C S5 1C S5 4 S5 2 W5 3 S5 1 S5 2 S5 4 S5 1 W5 3 S5 2 S5 1A S5 1 S5 2 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S5 4 S5 1 W5 2 S5 2 S5 4 S5 3 S5 1 W5 1A S5 1A S5 4 S5 2 W5 3 S5 2 S5 1 S5 1A S5 3 S5 4 S5 1 W5 1 S53 S5 2 S5 4 S5 2 W5 1C S5 2 S5 1A S5 2 S5 3 S5 4 S5 1 W5 2 S5 3 S5 4 S5 1 W5 1 S5 2 S5 4 S5 3 S5 1 W5 1 S5 2 S54 S5 3 S5 1 W5 1 S5 1 W5 2 S5 1A S5 4 S5 2 W5 3 S52 S5 1A S5 4 S5 2 W5 3 S5 2 S5 1A S5 4 S5 2 W5 3 S5 2 S51 S52 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S54 S5 1 W5 2 S4 4 S5 2 S5 1 W5 3 S5 1C S5 1 S54 S5 1 W5 3 S5 2 S5 2 S8 4 S8 1 W8 3 S8 1 S8 1A S4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:21:48 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.06B Author Checker 2247601 LEVEL 6 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA B1 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 1C S6 1 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 3 S6 1 W6 4 S6 1A S6 2 S6 3 S6 2 S6 1 W6 4 S6 1C S6 1 W6 4 S6 3 S6 1A S6 1C S6 2 S6 3 S6 4 S6 2 W6 1 S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S 1 S6 3 S64 S6 1 W6 2 S6 1C S6 2 S64 S6 3 S6 1 W6 1C S6 2 S63 S6 1 W6 4 S6 2 S6 3 S6 2 W6 4 S6 1 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:21:59 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.06C Author Checker 2247601 LEVEL 6 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA C1 4 S51 W5 3 S5 2 S5 1A S5 2 W5 4 S5 3 S5 1 S5 1A S5 3 S5 2 S5 4 S5 1 W5 2 S5 1A S5 3 S5 4 S5 1 W5 2 S5 3 S5 4 S5 1 W5 1A S5 1A S5 1 S5 2 S5 3 S5 4 S5 2 W5 4 S5 1C S5 3 S5 4 S5 1 W5 2 S5 2 S5 3 S5 4 S5 1 W5 1A S5 1 S5 4 S5 2 W5 2 W5 2 S5 1C S5 3 S5 3 S5 4 S5 2 S5 1 S5 1C S5 2 S5 3 S5 4 S5 1 W5 1 S5 2 S5 3 S5 4 S5 1 W5 1 S5 1A S5 1 W5 4 S5 3 S5 2 S5 1 S5 1 S5 4 S5 1 W5 2 S5 3 S5 1C S51C S5 3 S5 2 S5 1 S5 4 S5 1 W5 1 S5 2 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S5 4 S5 1 W5 2 S5 2 S5 3 S54 S5 1 W5 1A S5 2 S5 3 S5 4 S5 1 W5 1C S5 2 S8 3 S84 S8 1 W8 2 S83 S8 1A S8 1 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 2 S3 3 S3 4 S3 1 S3 2 S3 3 S3 4 S3 1 S3 1 S3 2 S3 3 S3 4 S3 1C S3 1 S5 4 S5 2 W5 2 S5 3 S5 1A S5 1A S5 2 W5 4 S5 3 S5 2 S51 S5 1A S5 2 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:22:12 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.07A Author Checker 2247601 LEVEL 7 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA A1 2 S6 3 S6 2 W6 1 S6 2 W5 4 S5 1 S5 2 S5 3 S5 1C S5 1C S5 4 S5 2 W5 3 S5 1 S5 2 S5 4 S5 1 W5 3 S5 2 S5 1A S5 1 S5 2 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S5 4 S5 1 W5 2 S5 2 S5 4 S5 3 S5 1 W5 1A S5 1A S5 4 S5 2 W5 3 S5 2 S5 1 S5 1A S5 3 S5 4 S5 1 W5 1 S53 S5 2 S5 4 S5 2 W5 1C S5 2 S5 1A S5 2 S5 3 S5 4 S5 1 W5 2 S5 3 S5 4 S5 1 W5 1 S5 2 S5 4 S5 3 S5 1 W5 1 S5 2 S54 S5 3 S5 1 W5 1 S5 1 W5 2 S5 1A S5 4 S5 2 W5 3 S52 S5 1A S5 4 S5 2 W5 3 S5 2 S5 1A S5 4 S5 2 W5 3 S5 2 S51 S52 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S54 S5 1 W5 2 S4 4 S5 2 S5 1 W5 3 S5 1C S5 1 S54 S5 1 W5 3 S5 2 S5 2 S8 4 S8 1 W8 3 S8 1 S8 1A S4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:22:25 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.07B Author Checker 2247601 LEVEL 7 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA B1 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 1C S6 1 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 3 S6 1 W6 4 S6 1A S6 2 S6 3 S6 2 S6 1 W6 4 S6 1C S6 1 W6 4 S6 3 S6 1A S6 1C S6 2 S6 3 S6 4 S6 2 W6 1 S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S 1 S6 3 S64 S6 1 W6 2 S6 1C S6 2 S64 S6 3 S6 1 W6 1C S6 2 S63 S6 1 W6 4 S6 2 S6 3 S6 2 W6 4 S6 1 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:22:35 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.07C Author Checker 2247601 LEVEL 7 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA C1 2 S5 4 S51 W5 3 S5 2 S5 1A S5 2 W5 4 S5 3 S5 1 S5 1A S5 3 S5 2 S5 4 S5 1 W5 2 S5 1A S5 3 S5 4 S5 1 W5 2 S5 3 S5 4 S5 1 W5 1A S5 1A S5 1 S5 2 S5 3 S5 4 S5 2 W5 4 S5 1C S5 3 S5 4 S5 1 W5 2 S5 2 S5 3 S5 4 S5 1 W5 1A S5 1 S5 4 S5 2 W5 2 W5 2 S5 1C S5 3 S5 3 S5 4 S5 2 S5 1 S5 1C S5 2 S5 3 S5 4 S5 1 W5 1 S5 2 S5 3 S5 4 S5 1 W5 1 S5 1A S5 1 W5 4 S5 3 S5 2 S5 1 S5 1 S5 4 S5 1 W5 2 S5 3 S5 1C S51C S5 3 S5 2 S5 1 S5 4 S5 1 W5 1 S5 2 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S5 4 S5 1 W5 2 S5 2 S5 3 S54 S5 1 W5 1A S5 2 S5 3 S5 4 S5 1 W5 1C S5 2 S8 3 S84 S8 1 W8 2 S83 S8 1A S8 1 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 2 S3 3 S3 4 S3 1 W3 1 S3 2 S3 3 S3 4 S3 1 W3 1 S3 1 S3 2 S3 3 S3 2 W3 4 S3 1C S3 1 S5 4 S5 2 W5 2 S5 3 S5 1A S5 1A S5 2 W5 4 S5 3 S5 2 S51 S5 1A S5 2 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:22:49 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.08A Author Checker 2247601 LEVEL 8 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA A1 2 S6 3 S6 2 W6 1 S6 2 W5 4 S5 1 S5 2 S5 3 S5 1C S5 1C S5 4 S5 2 W5 3 S5 1 S5 2 S5 4 S5 1 W5 3 S5 2 S5 1A S5 1 S5 2 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S5 4 S5 1 W5 2 S5 2 S5 4 S5 3 S5 1 W5 1A S5 1A S5 4 S5 2 W5 3 S5 2 S5 1 S5 1A S5 3 S5 4 S5 1 W5 1 S53 S5 2 S5 4 S5 2 W5 1C S5 2 S5 1A S5 2 S5 3 S5 4 S5 1 W5 2 S5 3 S5 4 S5 1 W5 1 S5 2 S5 4 S5 3 S5 1 W5 1 S5 2 S54 S5 3 S5 1 W5 1 S5 1 W5 2 S5 1A S5 4 S5 2 W5 3 S52 S5 1A S5 4 S5 2 W5 3 S5 2 S5 1A S5 4 S5 2 W5 3 S5 2 S51 S52 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S54 S5 1 W5 2 S4 4 S5 2 S5 1 W5 3 S5 1C S5 1 S54 S5 1 W5 3 S5 2 S5 2 S8 4 S8 1 W8 3 S8 1 S8 1A S4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:23:03 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.08B Author Checker 2247601 LEVEL 8 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA B1 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 1C S6 1 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 1 S6 1C S6 3 S6 2 W6 4 S6 2 S6 3 S6 1 W6 4 S6 1A S6 2 S6 3 S6 2 S6 1 W6 4 S6 1C S6 1 W6 4 S6 3 S6 1A S6 1C S6 2 S6 3 S6 4 S6 2 W6 1 S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S6 2 W6 4 S6 1 S6 3 S6 2 S6 1C S 1 S6 3 S64 S6 1 W6 2 S6 1C S6 2 S64 S6 3 S6 1 W6 1C S6 2 S63 S6 1 W6 4 S6 2 S6 3 S6 2 W6 4 S6 1 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:28:06 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.08C Author Checker 2247601 LEVEL 8 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA C1 2 S5 4 S51 W5 3 S5 2 S5 1A S5 2 W5 4 S5 3 S5 1 S5 1A S5 3 S5 2 S5 4 S5 1 W5 2 S5 1A S5 3 S5 4 S5 1 W5 2 S5 3 S5 4 S5 1 W5 1A S5 1A S5 1 S5 2 S5 3 S5 4 S5 2 W5 4 S5 1C S5 3 S5 4 S5 1 W5 2 S5 2 S5 3 S5 4 S5 1 W5 1A S5 1 S5 4 S5 2 W5 2 W5 2 S5 1C S5 3 S5 3 S5 4 S5 2 S5 1 S5 1C S5 2 S5 3 S5 4 S5 1 W5 1 S5 2 S5 3 S5 4 S5 1 W5 1 S5 1A S5 1 W5 4 S5 3 S5 2 S5 1 S5 1 S5 4 S5 1 W5 2 S5 3 S5 1C S51C S5 3 S5 2 S5 1 S5 4 S5 1 W5 1 S5 2 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S5 4 S5 1 W5 2 S5 2 S5 3 S54 S5 1 W5 1A S5 2 S5 3 S5 4 S5 1 W5 1C S5 2 S8 3 S84 S8 1 W8 2 S83 S8 1A S8 1 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 1A S8 2 S8 3 S8 4 S8 1 W8 2 S3 3 S3 4 S3 1 W3 1 S3 2 S3 3 S3 4 S3 1 W3 1 S3 1 S3 2 S3 3 S3 2 W3 4 S3 1C S3 1 S5 4 S5 2 W5 2 S5 3 S5 1A S5 1A S5 2 W5 4 S5 3 S5 2 S51 S5 1A S5 2 S5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:23:18 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.09A Author Checker 2247601 LEVEL 9-10 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 9-10 -FLOOR PLAN -AREA A1 2 W5 4 S5 1 S5 2 S5 3 S5 1C S5 1C S5 4 S5 2 W5 3 S5 1 S5 2 S5 4 S5 1 W5 3 S5 2 S5 1A S5 1 S5 2 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S5 4 S5 1 W5 2 S5 2 S5 4 S5 3 S5 1 W5 1A S5 1A S5 4 S5 2 W5 3 S5 2 S5 1 S5 1A S5 3 S5 4 S5 1 W5 1 S53 S5 2 S5 4 S5 2 W5 1C S5 2 S5 1A S5 2 S5 3 S5 4 S5 1 W5 2 S5 3 S5 4 S5 1 W5 1 S5 2 S5 4 S5 3 S5 1 W5 1 S5 2 S54 S5 3 S5 1 W5 1 S5 1 W5 2 S5 1A S5 4 S5 2 W5 3 S52 S5 1A S5 4 S5 2 W5 3 S5 2 S5 1A S5 4 S5 2 W5 3 S5 2 S51 S52 S5 3 S5 4 S5 2 W5 1A S5 1A S5 3 S54 S5 1 W5 2 S4 4 S5 2 S5 1 W5 3 S5 1C S5 1 S54 S5 1 W5 3 S5 2 S5 2 S8 4 S8 1 W8 3 S8 1 S8 1A S4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:23:27 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP02.09B Author Checker 2247601 LEVEL 9-10 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 9-10 -FLOOR PLAN -AREA B1 2" 3" 3" 2" 2" 3/4" 3/4" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2"1/2" 3/4" 3/4" 3/4"3/4" 1/2" 1/2" 1/2" 3/4" KS-1 IMB WHE-1 HD WMBBT-1 WC-1 LAV-1 1 S 4 S 3 S 2 S 1 W 4 S 3"3" 2" 2" 2" 1/2" 1/2" 1/2" 3/4" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4"1A S 1 W 2 S3 S HD WC-1 LAV-1 BT-1 LAV-1 KS-1 IMB WHE-1 WHE-1 HD 4 S 3 S 1 W 3"3" 2" 2" 2" 3/4" 3/4" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 1/2" 3/4" 1/2"1/2" 3/4" 3/4" 1/2" 1/2" 3/4" 3/4" 1 S 2 S KS-1IMB WMB BT-1 WC-1LAV-1 4 S 1/2"1/2" 3/4" 3/4" 1 W WHE-1 3/4" 3/4" 1/2" 3/4" 3/4" 3/4" 1/2" 1/2" 2"3" 3" 2" 1/2" 1/2" 1/2" 3/4" 3/4"3/4" 1/2" 1/2" 1/2" 1/2" 2 S 1A SBT-1 WC-1 LAV-1 LAV-1 KS-1 IMB WMB 3 S 1. PROVIDE WALL BOX IN PLENUM SPACE WITH SNAP ON GRILL FOR CONDENSATE DRAINAGE, T&P VALVE AND PAN. 2. PROVIDE SHUT-OFF VALVE AND REMOTE WATER METER. PLUMBING GENERAL NOTES DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:23:29 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP04.01 Author Checker 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/4" = 1'-0" UNIT S21 Scale: 1/4" = 1'-0" UNIT A12 Scale: 1/4" = 1'-0" UNIT A63 Scale: 1/4" = 1'-0" UNIT AD24 2 W WHE-2 1"1" 3/4" 3/4" 1/2" 1/2" 3/4"3/4" 1/2" 1/2" 3/4"3/4" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 1/2" 1/2" 3/4" 3/4" 3/4" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4"3/4" 3/4" 2" 3" 2" 2" 3" 3" 3" 2" 2" 2" 4 S 3 S 2 S 1 S 1A SLAV-1 LAV-1 WC-1 BT-1 HD WMB KS-1 LAV-1 WC-1 BT-1 2 W WHE-2 1" 1" 4 S HD 3" 3" 2" 2" 3"3" 2" 2" 2" 1/2" 1/2" 1/2"1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2"1/2" 1" 1" 1" 1" 1/2" 3/4"1/2" 1/2"1/2"1/2" 3 S2 S 1C S 1 S WMB KS-1 IMB SH-1 LAV-1 LAV-1 WC-1 LAV-1 WC-1 BT-13/4" 3/4" 2 W WHE-2 HD 2" 2" 2" 3"3" 3"3" 2" 2" 2" 1"1" 3/4" 3/4"3/4" 1/2" 1/2" 3/4"3/4" 1/2" 3/4" 3/4" 1/2" 1/2" 3/4" 3/4" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 3/4" WMB LAV-1 LAV-1 WC-1 SH-1 KS-1 IMB LAV-1 WC-1 BT-1 3/4" 3/4" 1" 1/2" 1/2"3/4" 1/2"1/2" 1/2"4 S1C S 2 S 1 S 3 S 1. PROVIDE WALL BOX IN PLENUM SPACE WITH SNAP ON GRILL FOR CONDENSATE DRAINAGE, T&P VALVE AND PAN. 2. PROVIDE SHUT-OFF VALVE AND REMOTE WATER METER. PLUMBING GENERAL NOTES DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 10:23:31 AM D:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-P-r22_RogerE.rvtP04.02 Author Checker 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By: Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/4" = 1'-0" UNIT B11 Scale: 1/4" = 1'-0" UNIT B22 Scale: 1/4" = 1'-0" UNIT BA13 CO2 CN S TS T A CD CONDENSATE DRAINAGE REF-L REF-S REFRIGERANT-LIQUID REFRIGERANT-SUCTION 2" PIPING SYMBOLS KEYNOTE CONTINUATION SYMBOL NUMBER OF SHEET WHERE DETAIL APPEARS NUMBER OF DETAIL ON SHEET REVISION NUMBER -SHOWN ON PLANS ROOM NAME AND NUMBER AREA NOT IN CONTRACT ABOVE GROUND PIPING (NEW) PIPE SIZE TAG (DIAMETER) PIPE RISEPIPE DROP PIPE TEE 1 - --- * NOTE * THE SYMBOLS AND ABBREVIATIONS SHOWN ON THIS SHEET MAY OR MAY NOT BE USED IN THIS SET OF DRAWINGS. Room 15 16x8 16/8 F S M B D C 16Ø EA OA TA RA SA EXHAUST AIR OUTSIDE AIR RETURN AIR SUPPLY AIR TRANSFER AIR GRILLES, REGISTERS & DIFFUSERS TAG CFM NECK SIZE / MODULE SIZE NEW OVAL DUCT SIZE TAG (WIDTH / HEIGHT) NEW SQUARE DUCT SIZE TAG (WIDTH x HEIGHT) MECHANICAL SYMBOLS RECTANGULAR SUPPLY/OUTSIDE AIR DUCT RISE RECTANGULAR RETURN/TRANSFER AIR DUCT RISE MECHANICAL EQUIPMENT TAGS NEW ROUND DUCT SIZE TAG (DIAMETER) LINEAR DIFFUSER TAG CFMTYPE (SEE SCHEDULE) NECK SIZE ROUND SUPPLY/OUTSIDE AIR DUCT RISE ROUND RETURN/TRANSFER AIR DUCT RISE RECTANGULAR EXHAUST/RELIEF AIR DUCT RISE ROUND EXHAUST/RELIEF AIR DUCT RISE DROP DROP DROP DROP DROP DROP GE GREASE EXHAUST AIR EQUIPMENT BY OTHERS (REFER TO OTHER DISCIPLINE FOR ADDITIONAL INFORMATION) FLUE EXHAUST GAS FLUE TYPE (SEE SCHEDULE) PIPE ACCESSORY TAGS SENSOR TAGS DAMPER TAGS MANUAL BALANCING DAMPER BACKDRAFT DAMPER FIRE DAMPER SMOKE DAMPER MOTORIZED DAMPER SENSOR THERMOSTAT TEMPERATURE SENSOR COMBINATION CO/NO2 SENSOR CARBON DIOXIDE SENSOR CAP 10"A 400SQUARE LAY-IN AIR DEVICE CEILING GRILLE/REGISTER LINEAR AIR DEVICE ROUND AIR DEVICE 12"C 400 12x10SG5500 48x3E400 8"J 200 LINEAR SLOT DIFFUSER HP XX Ø ROUND (F)FUTURE A/C ABOVE CEILING AAV AUTOMATIC AIR VENT ABV ABOVE AC AIR CONDITIONING ACC AIR COOLED CONDENSER ACCH AIR COOLED CHILLER ACF AIR CURTAIN FAN AD ACCESS DOOR ADD ADDENDUM AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFUE ANNUAL FUEL UTILIZATION EFFICIENCY AH AIR HANDLER AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT ALT ALTERNATE ALUM ALUMINUM AP ACCESS PANEL ARCH ARCHITECT/ARCHITECTURAL AS AIR SEPARATOR B BOILER BAS BUILDING AUTOMATION SYSTEM BDD BACKDRAFT DAMPER BF BOOSTER FAN BFF BELOW FINISHED FLOOR BLW BELOW BOD BOTTOM OF DUCT BPD BYPASS DAMPER BTU BRITISH THERMAL UNITS BTUH BRITISH THERMAL UNITS PER HOUR C AIR COMPRESSOR CAP CAPACITY CD CONDENSATE DRAIN CEH CEILING HEATER CF CIRCULATION FAN CFM CUBIC FEET PER MINUTE CH WATER-COOLED CHILLER CH CHILLER CHP CHILLED WATER PUMP CLG COOLING CO CLEAN OUT COP COEFFICIENT OF PERFORMANCE CRD CEILING RADIATION DAMPER CRP CONDENSATE RECEIVER & PUMP CT COOLING TOWER CU AIR COOLED CONDENSING UNIT CUH CABINET UNIT HEATER CW COLD WATER CWP CONDENSER WATER PUMP D DEGREE DAD DUCT ACCESS DOOR DB DRY BULB DE DISHWASHER EXHAUST DIA DIAMETER DN DOWN DP DEW POINT DS DUCT SILENCER EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EBH ELECTRIC BASEBOARD HEATER EF EXHAUST FAN ELEC ELECTRICAL EPF ELEVATOR PRESSURIZATION FAN EQUIP EQUIPMENT ER EXHAUST REGISTER ERU ENERGY RECOVERY UNIT ERV ENERGY RECOVERY VENTILATOR ESP EXTERNAL STATIC PRESSURE ET EXPANSION TANK EUH ELECTRIC UNIT HEATER EWC ELECTRIC WATER COOLER EWH ELECTRIC WALL HEATER EWT ENTERING WATER TEMPERATURE EX EXISTING EXIST EXISTING F DEGREES FAHRENHEIT FA FREE AREA FCU FAN COIL UNIT FD FLOOR DRAIN FD FIRE DAMPER FL FLOOR FO FUEL OIL FOF FUEL OIL FILL FOR FUEL OIL RETURN FOS FUEL OIL SUPPLY FOT FLAT ON TOP FOV FUEL OIL VENT FPM FEET PER MINUTE FSCP FIREFIGHTERS SMOKE CONTROL PANEL FSD COMBINATION FIRE/SMOKE DAMPER FT HD H2O FEET OF WATER FT FOOT/FEET GAL GALLON GC GENERAL CONTRACTOR GE GREASE EXHAUST GEF GARAGE EXHAUST FAN GPM GALLONS PER MINUTE GR GRILLE (AIR DEVICE WITHOUT A BALANCING DAMPER) GUH GAS FIRED UNIT HEATER GWP GLYCOL WATER PUMP H HUMIDISTAT HEX HEAT EXCHANGER HP HEAT PUMP HP HORSE POWER HSPF HEATING SEASONAL PERF HTG HEATING HV HEATING AND VENTILATING UNIT HVLS HIGH VOLUME LOW SPEED HW HOT WATER HWP HOT WATER PUMP ID INSIDE DIAMETER IEER INTEGRATED ENERGY EFFICIENCY RATIO IH INTAKE HOOD IN INCH IRH INFRARED HEATER KEF KITCHEN HOOD EXHAUST FAN KW KILOWATT LAT LEAVING AIR TEMPERATURE LB POUND LB/HR POUNDS PER HOUR LP LOW PRESSURE LPG LIQUEFIED PETROLEUM GAS LSW LOW SIDEWALL (12" AFF) LWT LEAVING WATER TEMPERATURE MAT MIXED AIR TEMPERATURE MAU MAKE-UP AIR UNIT MAV MANUAL AIR VENT MAX MAXIMUM MBH ONE THOUSAND BTU PER HOUR MD MOTORIZED DAMPER MECH MECHANICAL MFR MANUFACTURER MIN MINIMUM MISC MISCELLANEOUS MOV MOTORIZED VALVE MT MOUNT MTR MOTOR MU/A MAKE-UP/AIR MVD MANUAL VOLUME DAMPER N/A NOT APPLICABLE NC NOISE CRITERIA NC NORMALLY CLOSED (FAIL CLOSED) NIC NOT IN CONTRACT NO NUMBER NO NORMALLY OPEN (FAIL OPEN) NTS NOT TO SCALE OA OUTSIDE AIR OAU OUTSIDE AIR UNIT OBD OPPOSED BLADE DAMPER OC ON CENTER OD OUTSIDE DIAMETER OED OPEN ENDED DUCT OPG OPENING ORD OVERFLOW ROOF DRAIN PCHP PRIMARY CHILLED WATER PUMP PD PRESSURE DROP PDU POOL DEHUMIDIFICATION UNIT PER POOL EQUIPMENT ROOM PIU FAN-POWERED INDUCTION UNIT PLBG PLUMBING POC POINT OF CONNECTION PRESS PRESSURE PRV PRESSURE REDUCING VALVE PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE PTAC PACKAGED TERMINAL AIR CONDITIONER PTHP PACKAGED TERMINAL HEAT PUMP R RISE RA RETURN AIR RCP RADIANT CEILING PANEL REC RECESSED RED REDUCER REG REGISTER (AIR DEVICE WITH FACE OPERATED BALANCING DAMPER) RLA RELIEF AIR RH RELIEF HOOD RH RELATIVE HUMIDITY RHG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RL/A RELIEF AIR RM ROOM RPM REVOLUTIONS PER MINUTE RS REFRIGERANT SUCTION RTU ROOF TOP UNIT S/A SUPPLY AIR SA SUPPLY AIR SCHP SECONDARY CHILLED WATER PUMP SCU WATER-COOLED SELF-CONTAINED AIR CONDITIONING UNIT SD SMOKE DAMPER SEER SEASONAL ENERGY EFFICIENCY RATIO SEF SMOKE EXHAUST FAN SENS SENSIBLE SF SUPPLY FAN SF SQUARE FOOT SG SUPPLY GRILLE SM SURFACE MOUNT SPF STAIR PRESSURIZATION FAN SR SUPPLY REGISTER SS STAINLESS STEEL (TYPE 316 UNO) SSF SOLIDS SEPARATION FILTRATION UNIT STM STEAM T THERMOSTAT TD TRANSFER DUCT TD TEMPERATURE DROP TE TOILET EXHAUST TEMP TEMPERATURE TOD TOP OF DUCT TSTAT THERMOSTAT TWP TEMPERED WATER PUMP TXR TRANSFER TYP TYPICAL UCD UNDER CUT DOOR UG UNDERGROUND UNO UNLESS NOTED OTHERWISE V VENT VAV VARIABLE AIR VOLUME VENT VENTILATION VFD VARIABLE FREQUENCY DRIVE VRV/VRF VARIABLE REFRIGERANT VOLUME VARIABLE REFRIGERANT FLOW VTAC VERTICAL PACKAGED TERMINAL AC UNIT VVT VARIABLE VOLUME/VARIABLE TEMPERATURE TERMINAL UNIT WB WET BULB WC WATER COLUMN WG WATER GAUGE WL WALL LOUVER WMS WIRE MESH SCREEN WSHP WATER SOURCE HEAT PUMP ZD ZONE DAMPER ABBREVIATIONS PIPE TEE FROM BOTTOM PIPE TEE FROM TOP PIPE FITTINGS CEILING RADIATION DAMPER CO/NO2 GAS DETECTION SYSTEM ALARM DUCT TRANSITION16x824x8 LINED DUCT FLEX DUCT DUCT SMOKE DETECTOR DRYER BOX WALL CAP 12x10SG5500SIDEWALL GRILLE/ REGISTER AIRFLOW SYMBOLS SUPPLY RETURN / INTAKE / EXHAUST UCD 1" UNDERCUT DOOR WALL LOUVER TURNING VANES GRD TAKEOFF (SEE DETAILS) MECHANICAL EQUIPMENT WITH SERVICE AND AIRFLOW CLEARANCES (AS REQUIRED BY THE MANUFACTURER) HP XX NEW EQUIPMENT PLENUM RATED SOFFIT NON-PLENUM RATED SOFFIT CO A R CONSTANT AIRFLOW REGULATOR COMBINATION FIRE/SMOKE DAMPER THE MECHANICAL CONTRACTOR SHALL COORDINATE THE ELECTRICAL CHARACTERISTICS OF ALL HVAC EQUIPMENT (VOLTAGE, PHASE, MCA, MOCP, ETC.) WITH THE ELECTRICAL CONTRACTOR AND THE ELECTRICAL PLANS PRIOR TO SUBMITTING OR ORDERING ANY MECHANICAL EQUIPMENT. ANY SUBSEQUENT MISMATCH BETWEEN THE MECHANICAL EQUIPMENT ELECTRICAL REQUIREMENTS AND THE ELECTRICAL SERVICE, AS DESIGNED AND PROVIDED, SHALL BE THE RESPONSIBILITY OF THE MECHANICAL CONTRACTOR WITH NO ADDITIONS TO THE CONTRACT. MECHANICAL/ELECTRICAL COORDINATION STATEMENTS REQUIRED BY HVAC GENERAL NOTES AND SPECIFICATION SECTION 230000 , PARAGRAPH 1.06.E SHALL BE INCLUDED WITH HVAC EQUIPMENT SUBMITTALS/SHOP DRAWINGS. MECH/ELEC COORDINATION DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:30:45 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM00.01 ALS SDW 2247601 COVER SHEET SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV MECHANICAL SHEET LIST Sheet Number Sheet Name M00.01 COVER SHEET M00.02 GENERAL NOTES M00.03 SEQUENCES M02.01A LEVEL 1 - FLOOR PLAN - AREA A M02.01B LEVEL 1 - FLOOR PLAN - AREA B M02.01C LEVEL 1 - FLOOR PLAN - AREA C M02.02A LEVEL 2 - FLOOR PLAN - AREA A M02.02B LEVEL 2 - FLOOR PLAN - AREA B M02.02C LEVEL 2 - FLOOR PLAN - AREA C M02.03A LEVEL 3 - FLOOR PLAN - AREA A M02.03B LEVEL 3 - FLOOR PLAN - AREA B M02.03C LEVEL 3 - FLOOR PLAN - AREA C M02.04A LEVEL 4 - FLOOR PLAN - AREA A M02.04B LEVEL 4 - FLOOR PLAN - AREA B M02.04C LEVEL 4 - FLOOR PLAN - AREA C M02.05A LEVEL 5 - FLOOR PLAN - AREA A M02.05B LEVEL 5 - FLOOR PLAN - AREA B M02.05C LEVEL 5 - FLOOR PLAN - AREA C M02.06A LEVEL 6 - FLOOR PLAN - AREA A M02.06B LEVEL 6 - FLOOR PLAN - AREA B M02.06C LEVEL 6 - FLOOR PLAN - AREA C M02.07A LEVEL 7 - FLOOR PLAN - AREA A M02.07B LEVEL 7 - FLOOR PLAN - AREA B M02.07C LEVEL 7 - FLOOR PLAN - AREA C M02.08A LEVEL 8 - FLOOR PLAN - AREA A M02.08B LEVEL 8 - FLOOR PLAN - AREA B M02.08C LEVEL 8 - FLOOR PLAN - AREA C M02.09A LEVEL 9-10 - FLOOR PLAN - AREA A M02.09B LEVEL 9-10 - FLOOR PLAN - AREA B M02.09C LEVEL 9 - LOW ROOF - FLOOR PLAN - AREA C M02.10A ROOF PLAN - AREA A M02.10B ROOF PLAN - AREA B M04.01 UNIT PLANS M04.02 UNIT PLANS M04.03 UNIT PLANS M04.04 UNIT PLANS M05.01 DETAILS M05.02 DETAILS M05.03 DETAILS M05.04 DETAILS M05.05 DETAILS M06.01 SCHEDULES M06.02 SCHEDULES M07.01 CALCULATIONS M07.02 CALCULATIONS PRICING NOTES THE INFORMATION CONTAINED WITHIN THESE DOCUMENTS IS GENERAL IN NATURE AND, AS SUCH, MAY NOT DESCRIBE ALL COMPONENTS OR CONDITIONS NECESSARY FOR THE COMPLETED PROJECT. THE CONTRACTOR, BY USING THESE DOCUMENTS AS PART OF ANY EFFORT TO ESTABLISH A GUARANTEED MAXIMUM PRICE (GMP) FOR CONSTRUCTION, ACKNOWLEDGES THE INCOMPLETE NATURE OF THE INFORMATION CONTAINED HEREIN, AND WILL THEREFORE, INCORPORATE REASONABLE AMOUNTS AND ASSUMPTIONS IN THEIR ESTIMATE NECESSARY TO PROVIDE A COMPLETE PROJECT THAT IS CONSISTENT WITH THE DESIGN INTENT OF THESE DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR ALL MECHANICAL ELECTRICAL, PLUMBING, AND FIRE PROTECTION FEATURES INDICATED IN THE DOCUMENTS AS COMPLETE, SAFE, AND WORKING SYSTEMS. ANY FEATURE INDICATED IN ONE DISCIPLINE'S DESIGN IS ASSUMED TO BE INCLUDED AND INCORPORATED IN ALL DISCIPLINES AND SHOULD BE COORDINATED BETWEEN SUB-CONTRACTORS AS NECESSARY AND REQUIRED FOR FULLY FUNCTIONING SYSTEMS. SHOULD THE CONTRACTOR NOTE ANY CONFLICTING OR CONTRADICTORY INFORMATION IN THESE DOCUMENTS, THEY ARE INSTRUCTED TO NOTIFY THE ARCHITECT IMMEDIATELY OR IDENTIFY THE ITEM AS A SEPARATE LINE ITEM AND PRICE THE MORE COSTLY OF THE DIFFERING CONDITIONS. PROVIDE COMPLETE, SAFE, AND WORKING CODE COMPLIANT SYSTEMS, INCLUDING DUCTWORK, PIPING, INSULATION, EQUIPMENT, DRAINS, CONTROLS, BALANCING DAMPERS, BALANCING VALVES, ETC. WITH THE ELECTRICAL SERVICE COORDINATED AND PROVIDED BY THE ELECTRICAL CONTRACTOR. AIR DISTRIBUTION SYSTEMS SHALL BE COMPLETE WITH DUCTWORK, GRILLES, REGISTERS, DIFFUSERS, BALANCING DAMPERS, BACK DRAFT DAMPERS, ETC. ALL OUTSIDE AIR INTAKE DUCT CONNECTIONS TO LOUVERS, HOODS OR FAN DRIVEN EQUIPMENT (FANS, AIR HANDLING UNITS, ENERGY RECOVERY UNITS, ETC.) SHALL BE PROVIDED WITH MOTOR OPERATED DAMPERS. DIFFUSERS, REGISTERS AND GRILLES SHALL BE COMPATIBLE WITH REFLECTED CEILING PLANS AS INDICATED ON THE ARCHITECTURAL DRAWINGS. THE SYSTEMS SHALL BE TESTED AND BALANCED AND MADE READY FOR USE. FIRE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND SMOKE DAMPERS SHALL BE PROVIDED TO PROTECT OPENINGS THROUGH RATED ASSEMBLIES AS INDICATED ON THE ARCHITECTURAL DRAWINGS. PROVIDE CEILING OR WALL ACCESS PANELS AS REQUIRED FOR REMOVAL, REPLACEMENT, INSPECTION AND GENERAL ACCESS FOR ALL EQUIPMENT AND ACCESSORIES INSTALLED ABOVE CEILINGS OR BEHIND WALLS, INCLUDING FIRE DAMPERS, SMOKE DAMPERS, MOTOR OPERATED DAMPERS, MANUAL BALANCING DAMPERS, VALVES, ETC. COORDINATE THE TYPE AND STYLE OF ACCESS PANELS REQUIRED WITH THE ARCHITECTURAL DOCUMENTS. ALL OUTSIDE AIR DUCTWORK (INCLUDING PLENUMS) SHALL BE INSULATED AND CONNECTED TO FCUs, ETC. WITH A MOTORIZED DAMPER INTERLOCKED WITH THE RESPECTIVE EQUIPMENT. INCLUDE PRICING TO PROVIDE TEMPORARY HEAT (ELECTRIC HEATERS SIZED AT 15 BTU/SF) FOR ALL UNOCCUPIED TENANT SPACES. PROVIDE AUXILIARY DRAIN PANS BELOW ALL FCUs, ETC. SERVING ELEVATOR MACHINE ROOMS, TELECOM ROOMS AND ELECTRICAL ROOMS. ROUTE DRAIN PIPING TO THE NEAREST PLUMBING DRAIN. ALL EQUIPMENT AND ACCESSORIES REQUIRING ELECTRICAL CONNECTIONS SHALL BE PROVIDED WITH ELECTRICAL SERVICE, WITH ELECTRICAL NEEDS AND SERVICE REQUIREMENTS COORDINATED WITH THE ELECTRICAL CONTRACTOR. ELECTRICAL SERVICE SHALL BE INCLUDED IN THE GMP PRICING. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:23:02 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM00.02 ALS SDW 2247601 GENERAL NOTES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV HVAC GENERAL NOTES 1.ALL MECHANICAL EQUIPMENT AND INSTALLATIONS SHALL CONFORM WITH THE REQUIREMENTS OF THE 2018 INTERNATIONAL MECHANICAL CODE, THE 2018 INTERNATIONAL BUILDING CODE, ASHRAE STANDARD 90.1-2010 AS ALLOWED BY THE 2018 INTERNATIONAL ENERGY CONSERVATION CODE, STATE AND LOCAL AMENDMENTS, NFPA 70 (NEC), 90A, 96, 101, UNDERWRITERS LABORATORIES (OR ETL) AND ALL APPLICABLE LOCAL CODES AND ORDINANCES. 2.THE LOCATIONS, ARRANGEMENT AND EXTENT OF EQUIPMENT, PIPING, SUPPORTS, DEVICES, CONDUIT, AND OTHER APPURTENANCES RELATED TO THE INSTALLATION OF THE MECHANICAL AND ELECTRICAL WORK SHOWN ARE APPROXIMATE. THE DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE THE DRAWINGS, BUT REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS OF BUILDING COMPONENTS. SHOULD A CONFLICT EXIST BETWEEN THE ARCHITECTURAL AND ENGINEERING DRAWINGS REGARDING DIMENSIONS, SCALE, ETC., NOTIFY THE ARCHITECT IMMEDIATELY. 3.MATERIALS, EQUIPMENT OR LABOR NOT INDICATED, BUT WHICH CAN BE REASONABLY INFERRED TO BE NECESSARY FOR A COMPLETE INSTALLATION SHALL BE PROVIDED. THE DRAWINGS AND SPECIFICATIONS DO NOT UNDERTAKE TO INDICATE EVERY ITEM OF MATERIAL, EQUIPMENT OR LABOR REQUIRED TO PRODUCE A SAFE, COMPLETE AND PROPERLY OPERATING SYSTEM. 4.PRIOR TO PURCHASING ANY MATERIALS OR STARTING ANY WORK, CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, DUCTWORK SIZES AND LOCATIONS, EQUIPMENT, ETC. SHOWN ON THE DRAWINGS OR AFFECTING THIS WORK AND SHALL REPORT ANY DEVIATIONS TO THE ARCHITECT. 5.SHOP DRAWINGS SHALL BE SUBMITTED TO AND APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO ORDERING, PURCHASING, OR FABRICATING ANY MECHANICAL EQUIPMENT. SHOP DRAWINGS SHALL INCLUDE: ALL EQUIPMENT SCHEDULED OR SPECIFIED ON THE DRAWINGS; DUCTWORK DRAWN TO 1/4" SCALE OR THE SCALE SHOWN ON THE DRAWINGS; PARKING GARAGE CO/NO2 MONITORING AND CONTROL SYSTEM LAYOUT PREPARED BY THE SYSTEM MANUFACTURER INCLUDING SENSOR LOCATIONS, SEQUENCE OF OPERATION AND PRODUCT DATA; MECHANICAL VENTILATION CONTROLLERS, WALL CAPS, REFRIGERANT PIPING AND CONTROL WIRING SCHEMATICS CERTIFIED BY THE AIR CONDITIONING EQUIPMENT MANUFACTURER. A.WHERE SPLIT SYSTEMS ARE USED IN A “LONG LINE APPLICATION,”SUBMIT MANUFACTURER’S REFRIGERANT LINE SET ROUTING DRAWINGS AND ENGINEERED CALCULATIONS SUPPORTING INSTALLED LINE LENGTHS AND RECOMMENDED SUCTION AND LIQUID LINE SIZES (DEVIATIONS IN THE INSTALLED LENGTHS AND SIZES SHALL BE RECORDED ON THE AS-BUILT DRAWINGS AND COORDINATED WITH THE MANUFACTURER TO RECONFIRM THAT LONG LINE GUIDELINES ARE BEING MET). IDENTIFY AND PROVIDE CUT SHEETS OF ANY AND ALL ACCESSORIES REQUIRED TO MAKE THE SYSTEM COMPLETE, FUNCTIONAL AND RELIABLE. b.FAILURE TO SUBMIT CERTIFIED REFRIGERANT PIPING DRAWINGS SHALL BE CAUSE FOR REJECTION OF THE ENTIRE SUBMITTAL AND DOES NOT RELIEVE THE CONTRACTOR OF COMPLYING WITH MANUFACTURER’S RECOMMENDATIONS. c.LONG LINE REFRIGERANT PIPING APPLICATIONS SHALL BE IN ACCORDANCE WITH THE MANUFACTURER’S CURRENT SPLIT SYSTEM LONG-LINE APPLICATION GUIDELINE. d.ANY SPLIT SYSTEM WITH 75 FEET OF SEPARATION BETWEEN THE OUTDOOR UNIT AND INDOOR UNIT REQUIRES THAT THE CONTRACTOR OBTAIN A WARRANTY APPROVAL LETTER FROM THE EQUIPMENT MANUFACTURER CERTIFYING THE LONG LINE LENGTH DISTANCES SHOWN ON THE SUBMITTED SHOP DRAWINGS ARE ACCEPTABLE. e.HVAC EQUIPMENT SUBMITTALS SHALL INCLUDE, BUT NOT BE LIMITED TO, DATA SHEETS FOR ALL SYSTEM COMPONENTS, FAN SELECTIONS WITH PERFORMANCE CURVES AT SITE CONDITIONS, ELECTRICAL CHARACTERISTICS (COORDINATED WITH ELECTRICAL SUBCONTRACTOR), WIRING DIAGRAMS, INSTALLATION, OPERATION AND MAINTENANCE MANUALS, AHRI RATING CERTIFICATES FOR ACTUAL EQUIPMENT TO BE INSTALLED. FAILURE TO SUBMIT AHRI CERTIFICATES IS CAUSE FOR REJECTION OF THE SUBMITTAL. SHOP DRAWINGS SHALL BE SUBMITTED SIMULTANEOUSLY IN ONE PACKAGE WITH EACH ITEM CLEARLY NOTED BY THE TAG USED ON THE DRAWINGS AND SPECIFICATION SECTION PERTAINING TO THE ITEM. 6.ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED AND MAINTAINED PER MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS. 7.ALL MECHANICAL EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER ACCEPTANCE BY OWNER. 8.ALL HVAC COMPRESSORS SHALL HAVE EXTENDED 4-YEAR MANUFACTURER'S WARRANTY FOR A 5-YEAR TOTAL WARRANTY. 9.FOR EXACT LOCATION OF OUTDOOR AIR CONDITIONING UNITS, SEE ARCHITECTURAL DRAWINGS. 10.INSTALL GRADE MOUNTED OUTDOOR AIR CONDITIONING EQUIPMENT LEVEL ON 2" (MIN.) THICK POLYPROPYLENE EQUIPMENT PAD 4" LARGER THAN OUTDOOR UNIT FOOTPRINT; DIVERSITECH "E LITE”PAD OR APPROVED EQUAL EXTENDING 4" BEYOND UNIT PERIMETER. 11.[INSTALL ROOF MOUNTED OUTDOOR AIR CONDITIONING EQUIPMENT LEVEL ON SUPPORTS AS INDICATED ON THE DETAIL SHEETS. MOUNT ALL EQUIPMENT ON 3/8”THICK NEOPRENE PADS (MINIMUM OF 4 PADS PER UNIT). ALL ROOFTOP MOUNTED EQUIPMENT SHALL BE INSTALLED PER DETAILS AND AS RECOMMENDED BY THE MANUFACTURER. 12.SPLIT SYSTEM OUTDOOR UNIT EQUIPMENT HAS BEEN SHOWN ON THE PLANS INDICATING MATCHED SYSTEMS OF THE INDOOR UNIT WITH ITS ASSOCIATED OUTDOOR UNIT. WHILE THE LOCATION OF THE OUTDOOR UNITS ARE APPROXIMATE, THE IMPORTANCE OF UNIT LOCATIONS IN RELATION TO THE REFRIGERANT LINE SET LENGTH IS CRITICAL FOR THE PROJECT. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION AND OBSERVE THE MANUFACTURER’S INSTALLATION INSTRUCTIONS FOR LONG LINE APPLICATIONS. REFRIGERANT LINE SETS SHALL BE INSTALLED TO REDUCE THE SYSTEM TOTAL EQUIVALENT LENGTH AND MINIMIZE SYSTEM CAPACITY LOSSES DUE TO ELBOWS, FITTINGS, VALVES, ETC. THAT COMPRISE THE ENTIRE REFRIGERANT PIPING SYSTEM. AFTER RECEIPT OF THE APPROVED SUBMITTALS, THE CONTRACTOR IS RESPONSIBLE TO COORDINATE THE REFRIGERANT PIPING SCHEMATICS CERTIFIED BY THE EQUIPMENT MANUFACTURER AND SUBMITTING THE REFRIGERANT PIPING DRAWINGS AS OUTLINED IN THE SHOP DRAWING NOTE ABOVE. 13.PORTIONS OF DUCTWORK AND PIPE INSULATION VISIBLE THROUGH AIR DISTRIBUTION DEVICES IN FINISHED AREAS SHALL BE PAINTED FLAT BLACK. 14.MOUNT TOP OF THERMOSTATS AND SENSORS AT 46" AFF UNLESS NOTED OTHERWISE. PROVIDE CLEAR LOCKING GUARD ASSEMBLIES FOR ALL PUBLIC AREA THERMOSTATS. COORDINATE THERMOSTAT LOCATIONS WITH ALL TRADES. COORDINATE FINAL LOCATIONS WITH THE GENERAL CONTRACTOR, INTERIOR DESIGNER AND THE OWNER PRIOR TO INSTALLATION. LOCATE ADJACENT TO LIGHT SWITCHES WHERE POSSIBLE. DO NOT LOCATE THERMOSTATS AT THE CENTER OR NEAR CENTER OF A WALL. THERMOSTATS SHALL BE MOUNTED NO CLOSER THAN 8" FROM THE CORNER OR END OF A WALL OR DOOR. ALL THERMOSTATS SHALL BE ADA COMPLIANT. 15.ALL WORK SHALL BE COORDINATED AND PERFORMED WITH PRIOR APPROVAL FROM THE OWNER TO SUIT HIS OPERATING CONDITIONS. 16.ANY EXISTING WALL, FLOOR, OR CEILING SURFACE THAT IS DISTURBED DURING THE COURSE OF THE HVAC WORK SHALL BE REPAIRED TO MATCH NEW AND/OR EXISTING CONDITIONS. 17.CAREFULLY COORDINATE ALL PENETRATIONS THROUGH EXTERIOR WALLS WITH ARCHITECTURAL DRAWINGS AND FINISHES.THE PENETRATIONS SHALL NOT BE LOCATED WHERE THEY WILL CONFLICT WITH ARCHITECTURAL FEATURES, TRANSITIONS IN MATERIALS, OR COLOR CHANGES IN MATERIALS. HORIZONTALLY ALIGN PENETRATIONS WHEREVER POSSIBLE UNLESS NOTED OTHERWISE. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO ANY WORK BEING DONE. 18.CAREFULLY COORDINATE ALL PENETRATIONS THROUGH THE ROOF WITH ARCHITECTURAL DRAWINGS.THE PENETRATIONS SHALL NOT BE LOCATED WHERE THEY WILL CONFLICT WITH ARCHITECTURAL FEATURES, EXPANSION JOINTS OR STRUCTURE. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO ANY WORK BEING DONE. 19.CONTRACTOR SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL EQUIPMENT, DUCTWORK, PIPING, ETC. TO FIT WITHIN THE SPACE ALLOWED BY THE ARCHITECTURAL AND STRUCTURAL CONDITIONS. CUTTING OR OTHERWISE ALTERING ANY STRUCTURAL MEMBERS SHALL NOT BE PERMITTED WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT. 20.SEAL THE ANNULAR SPACE AROUND ALL DUCT, PIPE, GRILLE, REGISTER, DIFFUSER, ETC. PENETRATIONS THROUGH WALLS, FLOORS AND CEILINGS AIRTIGHT WITH AN APPROVED MATERIAL (RE: ARCHITECTURAL DOCUMENTS FOR APPROVED MATERIALS). 21.AIR HANDLING UNITS, COOLING COILS, FAN COIL UNITS AND ANY OTHER EQUIPMENT THAT PRODUCES CONDENSATE AND IS LOCATED ABOVE A CEILING OR IN AN ATTIC SHALL BE INSTALLED WITH AN AUXILIARY DRAIN PAN BENEATH ANY COMPONENT THAT MAY PRODUCE CONDENSATE. INSTALL AN OVERFLOW SAFETY SWITCH IN THE COOLING COIL OVERFLOW DRAIN LINE OR A WATER LEVEL DETECTION DEVICE IN THE PRIMARY DRAIN PAN AND A WATER LEVEL DETECTION DEVICE IN THE AUXILIARY DRAIN PAN.ON DOWNFLOW UNITS OR OTHER EQUIPMENT WHERE AN AUXILIARY DRAIN PAN IS NOT POSSIBLE, INSTALL A WATER LEVEL DETECTION DEVICE IN THE PRIMARY DRAIN PAN OR AN OVERFLOW SAFETY SWITCH IN THE OVERFLOW DRAIN LINE CONNECTION.WATER LEVEL DETECTION DEVICES (CONFORMING TO UL508)SHALL BE WIRED TO SHUT DOWN THE AIR HANDLING UNIT. 22.THE GENERAL CONTRACTOR SHALL COORDINATE SERVICE ACCESS PATHS FOR ROOF MOUNTED EQUIPMENT REQUIRING ROUTINE MAINTENANCE. PROVIDE CODE COMPLIANT GALVANIZED STEEL CROSSING STRUCTURE (E.G. STAIRS WITH HANDRAILS, LADDERS, ETC.) FOR ANY OBSTRUCTION (DUCTWORK, PIPING, ETC.) THAT EXCEEDS 1’-6” IN HEIGHT X 1’-6”IN WIDTH. ATTIC CROSSINGS MAY BE CONSTRUCTED OF WOOD IF ALLOWED BY LOCAL CODE. DETAILS OF SUCH CROSSINGS SHALL BE INCLUDED WITH PIPING AND DUCTWORK LAYOUT AND COORDINATION DRAWINGS. ALL DUCTWORK, PIPING AND EQUIPMENT INSTALLATION SHALL COMPLY WITH THE FOLLOWING: a.INSTALL EQUIPMENT TO ALLOW MAXIMUM POSSIBLE HEADROOM UNLESS SPECIFIC MOUNTING HEIGHTS ARE NOT INDICATED. b.INSTALL EQUIPMENT LEVEL AND PLUMB, PARALLEL AND PERPENDICULAR TO OTHER BUILDING SYSTEMS AND COMPONENTS IN EXPOSED INTERIOR SPACES, UNLESS OTHERWISE INDICATED. c.INSTALL HVAC EQUIPMENT TO FACILITATE SERVICE, MAINTENANCE, AND REPAIR OR REPLACEMENT OF COMPONENTS. CONNECT EQUIPMENT FOR EASE OF DISCONNECTING, WITH MINIMUM INTERFERENCE TO OTHER INSTALLATIONS. EXTEND GREASE FITTINGS TO ACCESSIBLE LOCATIONS. d.INSTALL EQUIPMENT TO ALLOW RIGHT-OF-WAY FOR PIPING TO BE INSTALLED WITH THE REQUIRED SLOPE. e.FOR ROOF AND ATTIC MOUNTED EQUIPMENT REQUIRING ROUTINE MAINTENANCE, ALLOW FOR AN UNOBSTRUCTED PATH FROM THE ROOF/ATTIC SERVICE ENTRY POINT TO THE EQUIPMENT. THE PATH AREA SHALL BE A MINIMUM OF 6’-0”HIGH BY 3’-0”WIDE. 23.ALL PIPE AND DUCT PENETRATIONS OF FIRE AND/OR SMOKE-RATED ASSEMBLIES SHALL BE FIRE-STOPPED AS REQUIRED TO RESTORE THE ASSEMBLY TO ITS ORIGINAL INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE AS MANUFACTURED BY TREMCO, HILTI, 3M, STI, NELSON OR APPROVED EQUAL. 24.ACCESS PANELS IN NON-ACCESSIBLE CEILINGS AND IN WALLS TO ALLOW ADEQUATE ROOM FOR MAINTENANCE OF EQUIPMENT AND BALANCING OF SYSTEMS SHALL BE INSTALLED UNDER THE ARCHITECTURAL DIVISION. ACCESS PANELS IN CEILING AND WALLS SHALL BE PROVIDED WHERE SHOWN ON THE DRAWINGS OR WHERE NECESSARY TO ACCESS DAMPERS, VALVES, ETC. COORDINATE EXACT LOCATION OF ALL ACCESS PANELS WITH THE ARCHITECT DURING THE SHOP DRAWING PROCESS. 25.ACCESS DOORS SHALL BE INSTALLED AT ALL FIRE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS, SMOKE DAMPERS AND WHERE INDICATED FOR CEILING RADIATION DAMPERS TO FACILITATE INSPECTION AND MAINTENANCE. PERMANENTLY IDENTIFY THE ACCESS DOOR BY A DIE-CUT LABEL WITH ½”HIGH RED BLOCK LETTERS ON A WHITE BACKGROUND. LABEL SHALL READ “FIRE DAMPER”, “COMBINATION FIRE/SMOKE DAMPER”, “SMOKE DAMPER”OR “CEILING RADIATION DAMPER”. 26.ALL MECHANICAL EQUIPMENT SHALL BE LABELED WITH A 2”HIGH SEMI-RIGID PLASTIC LAMINATE NAMEPLATE WITH 1”HIGH WHITE LETTERS ON A BLACK BACKGROUND SECURELY AFFIXED TO THE EQUIPMENT. THE NAMEPLATE SHALL SHOW THE EQUIPMENT TAG USED ON THESE DRAWINGS. ON RESIDENTIAL PROJECTS, THE NAMEPLATE ON THE OUTDOOR EQUIPMENT SHALL INDICATE THE DWELLING UNIT NUMBER IT SERVES AS WELL AS THE EQUIPMENT ID TAG. 27.REFER TO ARCHITECTURAL PLANS FOR ALL DROPPED CEILINGS AND SOFFITS. CONTRACTOR SHALL ADVISE ARCHITECT AND ENGINEER OF ANY CONFLICTS BETWEEN ARCHITECTURAL AND MECHANICAL DRAWINGS. 28.REFER TO ARCHITECTURAL PLANS FOR FLOOR AND CEILING ASSEMBLY UL RATINGS AND DETAILS. 29.ALL MATERIALS EXPOSED WITHIN HVAC PLENUMS SHALL HAVE A FLAME-SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED RATING INDEX OF NOT MORE THAN 50 UNLESS OTHERWISE ALLOWED BY CODE. 30.THE FIRE SPRINKLER CONTRACTOR SHALL INSTALL AND LOCATE ALL FIRE SPRINKLER PIPING TO PREVENT PIPING FROM THE POTENTIAL OF FREEZING. THE FlRE SPRINKLER CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT AND COORDINATE WITH THE MECHANICAL AND ELECTRICAL CONTRACTORS IF HEATING IS REQUIRED. 31.COORDINATE ALL DUCTWORK WITH WOOD TRUSS SHOP DRAWINGS PRIOR TO INSTALLATION. 32.GENERAL CONTRACTOR SHALL COORDINATE THE INSTALLATION OF WOOD TRUSS SHOP DRAWINGS AND FIELD TRUSSES TO AVOID WOOD TRUSSES CONFLICTING WITH VERTICAL SHAFTS AND INDIVIDUAL AIR HANDLING UNIT DISCHARGE PLENUMS. 33.ALL AHUs WITH SUPPLY AIR DUCTED VERTICALLY THROUGH A CEILING RADIATION DAMPER SHALL BE PROVIDED WITH A MEANS TO SHUTDOWN THE AHU UPON DETECTION OF SMOKE IN THE DWELLING UNIT. REFER TO DETAILS FOR ADDITIONAL INFORMATION. 34.UNLESS NOTED OTHERWISE, THE ROOF CURB SHALL BE FURNISHED WITH THE EQUIPMENT IT SUPPORTS (SUBMIT WITH SHOP DRAWINGS). COORDINATE WITH THE ROOF SYSTEM USED SO THAT A MINIMUM OF 8" OF THE CURB IS ABOVE THE FINISHED ROOF FOR FLASHING PURPOSES. THE TOP OF THE CURB SHALL BE LEVEL AND THE SLOPE OF THE ROOF SHALL BE COMPENSATED FOR BY THE CURB. 35.DUCTWORK AND PIPING SHALL NOT BE INSTALLED IN ELECTRICAL ROOMS, TELECOM ROOMS, OR ELEVATOR EQUIPMENT ROOMS EXCEPT FOR DUCTWORK AND PIPING SERVING THAT SPECIFIC ROOM. DUCTWORK AND PIPING SHALL NOT BE ROUTED ABOVE ELECTRICAL EQUIPMENT PER THE NATIONAL ELECTRICAL CODE ARTICLE 110. 36.ROOFING: ROOF OPENINGS, PENETRATIONS AND CURBS SHALL BE AT LEAST 12 INCHES APART FROM OTHER ROOF PENETRATIONS, CURBS, WALL, AND DRAIN SUMP TO ALLOW FOR PROPER ROOFING SYSTEM FLASHING AND DETAILING. ROOF OPENINGS SHALL BE A MINIMUM OF 3’-0”FROM A PARAPET WALL AND A MINIMUM OF 5’-0”FROM A FIRE WALL EXTENDING THRU THE ROOF. 37.ROOFTOP MOUNTED EQUIPMENT SHALL BE LOCATED A MINIMUM OF 10’-0”FROM THE EDGE OF THE ROOF OR PARAPET. 38.ROOFTOP EQUIPMENT WIND RESISTANCE: THE CONTRACTOR SHALL PROVIDE SUPPORT FOR MECHANICAL ROOFTOP EQUIPMENT IN ORDER TO MEET CODE REQUIRED WIND RESISTANCE (RE: 2015 AND 2018 IMC “301.15 WIND RESISTANCE. MECHANICAL EQUIPMENT, APPLIANCES AND SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND INSTALLED TO RESIST THE WIND PRESSURE DETERMINED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE.” 39.STORAGE AND PROTECTION OF STORED MATERIALS: a.DURING CONSTRUCTION, ALL EQUIPMENT SHALL BE PROPERLY PROTECTED AGAINST DAMAGE, DEFACING AND FREEZING WITH SHIPPING CARTONS, PLASTIC SHEETING, SHIPPING COVERS, ETC. b.ALL OPEN ENDS OF PIPING AND EQUIPMENT SHALL BE SEALED WITH NIPPLES AND CAPS, PLUGS, AND TEST PLUGS UNTIL FINAL CONNECTION TO SYSTEM IS MADE. c.ALL EQUIPMENT, PIPING AND DUCTWORK SHALL BE PROTECTED TO PREVENT ENTRANCE OF FOREIGN MATTER AND DEBRIS BY COVERING EXPOSED OPENINGS DURING CONSTRUCTION. d.HANDLE AND STORE MATERIALS IN ACCORDANCE WITH MANUFACTURER’S AND SUPPLIER’S RECOMMENDATIONS AND IN A MANNER TO PREVENT DAMAGE TO MATERIALS DURING STORAGE AND HANDLING. REPLACE DAMAGED MATERIALS. e.EQUIPMENT AND MATERIALS SHALL NOT BE INSTALLED UNTIL SUCH TIME AS THE ENVIRONMENTAL CONDITIONS OF THE JOB SITE ARE SUITABLE TO PROTECT THE EQUIPMENT OR MATERIALS. EQUIPMENT OR MATERIALS DAMAGED, OR WHICH ARE SUBJECTED TO THESE ELEMENTS, ARE UNACCEPTABLE AND SHALL BE REMOVED FROM THE PREMISES AND REPLACED. f.PROTECT EQUIPMENT AND AIR DISTRIBUTION SYSTEMS AS OUTLINED IN SMACNA’S IAQ GUIDELINES FOR OCCUPIED BUILDINGS UNDER CONSTRUCTION, LATEST EDITION. TESTING, ADJUSTING AND BALANCING (RESIDENTIAL PROJECTS) 1.AFTER CONSTRUCTION, THE ENTIRE HVAC SYSTEM SHALL BE CLEANED, TESTED AND ADJUSTED TO SATISFY THE EQUIPMENT SCHEDULES AND AIR QUANTITIES SHOWN ON THE DRAWINGS. EXCEPT FOR OAFS (RE: NOTE 6 BELOW), INDIVIDUAL AIR DEVICES IN DWELLING LIVING UNITS DO NOT REQUIRE AN AIR TEST AND BALANCE BE PERFORMED. 2.ALL PARKING GARAGE MECHANICAL VENTILATION SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED TO PROVIDE AIR QUANTITIES INDICATED.IN ADDITION, THE COMPLETE SYSTEM OPERATION (FANS, SENSORS, CONTROLS, SEQUENCE OF OPERATION, ETC.) SHALL BE CERTIFIED BY THE MANUFACTURER. THE MANUFACTURER SHALL SUBMIT A LETTER STATING THAT THE SYSTEM IS OPERATING AS DESIGNED AND IN SAFE AND PROPER WORKING ORDER. 3.ALL AMENITY AREAS, AND PACKAGED ROOFTOP UNITS SHALL BE TESTED, ADJUSTED AND BALANCED TO SATISFY THE EQUIPMENT SCHEDULES AND AIR QUANTITIES SHOWN ON THE DRAWINGS. REGISTERS AND/OR DIFFUSERS SERVED FROM ROOFTOP UNITS AND DEDICATED OUTSIDE AIR SYSTEMS SHALL BE INDIVIDUALLY TESTED AND BALANCED AND AIR QUANTITIES RECORDED IN THE TAB REPORT. 4.COMMON AREAS -VENTILATION AIR DISTRIBUTION SYSTEMS (OUTDOOR AIR AND EXHAUST AIR) SHALL BE BALANCED TO ACHIEVE THE AIRFLOW RATES INDICATED ON THE DRAWINGS. THESE AIRFLOW RATES SHALL BE CONSIDERED MINIMUM RATES. THE MEASURED AIR BALANCE TOLERANCE FOR BOTH OUTDOOR AIR AND EXHAUST AIR RATES SHALL BE 0% TO +10%. 5.AFTER CONSTRUCTION, ALL HVAC FANS WITH MOTORS GREATER THAN 1 HP IN SIZE SHALL BE TESTED, ADJUSTED, AND BALANCED TO DELIVER THE AIR QUANTITIES SHOWN ON THE DRAWINGS. 6.WHEN TESTING AND BALANCING IS REQUIRED IN DWELLING UNITS, IT MUST BE COMPLETED AND THE TAB REPORT SUBMITTED PRIOR TO OCCUPANCY. COORDINATE WITH THE GENERAL CONTRACTOR, OWNER’S REPRESENTATIVE, AND MECHANICAL SUBCONTRACTOR TO SCHEDULE TAB WELL IN ADVANCE OF OCCUPANCY. 7.SUBMIT THE CERTIFIED (AABC OR NEBB) TEST AND BALANCE REPORT TO THE ARCHITECT FOR APPROVAL.REPORTS SHALL INCLUDE AIRFLOW, STATIC PRESSURE, AND TEMPERATURE TEST DATA. MECHANICAL/ELECTRICAL COORDINATION: 1.CONTRACTOR SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL EQUIPMENT WITH ELECTRICAL DRAWINGS PRIOR TO ORDERING EQUIPMENT OR SUBMITTING SHOP DRAWINGS AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. SHOP DRAWING SUBMITTALS SHALL CLEARLY STATE THAT THE ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT HAS BEEN COORDINATED WITH THE ELECTRICAL CONTRACT DOCUMENTS AND THE ELECTRICAL CONTRACTOR. 2.ALL MECHANICAL EQUIPMENT REQUIRING ELECTRICAL POWER SHALL BE INSTALLED WITH A DISCONNECT SWITCH AT EACH PIECE OF EQUIPMENT. COORDINATE SWITCH TYPE (FUSED OR NON-FUSED) WITH EQUIPMENT CHARACTERISTICS, MANUFACTURER'S RECOMMENDATIONS AND THE ELECTRICAL DRAWINGS. DISCONNECT SWITCH SHALL BE FURNISHED BY MECHANICAL FOR INSTALLATION BY ELECTRICAL. DISCONNECT SWITCHES SHALL NOT BE MOUNTED ON THE EQUIPMENT IT SERVES UNLESS INTEGRAL TO THE UNIT. 3.PROVIDE ALL SYSTEM CONTROLS AND ASSOCIATED CONTROL AND INTERLOCK WIRING FOR COMPLETE AND OPERABLE SYSTEMS. 120 VOLT AND HIGHER WIRING SHALL BE MC CABLE OR IN CONDUIT IN ACCORDANCE WITH LOCAL CODES AND THE MATERIALS AND INSTALLATION REQUIREMENTS OF DIVISION 26 -ELECTRICAL. 4.COORDINATE POWER AND FIRE ALARM REQUIREMENTS OF ALL COMBINATION FIRE/SMOKE DAMPERS AND SMOKE DAMPERS WITH THE ELECTRICAL CONTRACTOR. 5.ALL REQUIRED CONTROL WIRING (INCLUDING POWER WIRING REQUIRED FOR CONTROL PANELS, DEVICES, ETC.) NOT INDICATED ON THE ELECTRICAL DRAWINGS SHALL BE INCLUDED AS PART OF THE MECHANICAL WORK. WIRING IN HVAC PLENUM SPACES SHALL BE INSTALLED ACCORDING TO CODE REQUIREMENTS. 6.UNLESS NOTED OTHERWISE, TRANSFORMERS, CONTROLS AND CONTROL WIRING REQUIRED FOR ALL MECHANICAL SYSTEMS SHALL BE FURNISHED WITH THE EQUIPMENT IT SERVES AND INSTALLED BY THE MECHANICAL CONTRACTOR. MOTOR STARTERS FOR HVAC EQUIPMENT SHALL BE FURNISHED WITH THE MOTOR OR APPARATUS WHICH IT OPERATES. MOTOR STARTER INSTALLATION SHALL BE BY THE DIVISION 26 CONTRACTOR. 7.MAINTAIN REQUIRED NEC CLEARANCES FOR ALL POWERED MECHANICAL EQUIPMENT. THE CLEAR WIDTH SHALL BE THE WIDTH OF THE EQUIPMENT OR 2’-6”(MINIMUM). THE FOLLOWING CLEARANCE IN FRONT OF THE EQUIPMENT SHALL BE: a.FOR 208/240V EQUIPMENT: 3’-0”CLEARANCE b.FOR 480V EQUIPMENT: 3’-0”CLEARANCE: CONDITION 1 –OPEN AREA, NO OBSTRUCTIONS; 3’-6”CLEARANCE –CONDITION 2 –GROUNDED EQUIPMENT, OR CONCRETE/STEEL WALL ON OPPOSING SIDE; 4’CLEARANCE –CONDITION 3 –LIVE PARTS TO LIVE PARTS. 8.CLEARANCES FOR ELECTRIC DUCT HEATERS AND LOW VOLTAGE CONTROL PANELS LOCATED ABOVE CEILINGS: THE CONTRACTOR SHALL COORDINATE AND PLAN THE WORK TO ALLOW FOR A CLEAR SPACE IN FRONT OF ALL ELECTRIC DUCT HEATER CONTROL PANELS (INCLUDING, BUT NOT LIMITED TO AHUS, FCUS, VAVs, PIUs, UHs, ETC.) OF 42” X 30”WIDE (OR THE WIDTH OF THE PANEL WHICHEVER IS GREATER). THE CONTROL PANEL DOOR SHALL BE ALLOWED TO OPEN AT LEAST 90 DEGREES. EQUIPMENT WITHOUT DUCT HEATERS THAT HAVE LOW VOLTAGE CONTROL PANELS SHALL HAVE A MINIMUM CLEAR SPACE IN FRONT OF THE PANEL OF 24”X 24”WIDE (OR THE WIDTH OF THE PANEL WHICHEVER IS GREATER). 9.ROUTING OF PIPING AND DUCTWORK SHALL BE COORDINATED WITH THE ELECTRICAL CONTRACTOR AND ALL OTHER TRADES DURING THE SUBMITTAL AND LAYOUT PHASE. PIPING AND DUCTWORK SHALL NOT BE ROUTED THROUGH THE DEDICATED ELECTRICAL SPACE ABOVE EACH LOAD CENTER. 10.MOTORS CONTROLLED BY A VARIABLE FREQUENCY DRIVE (VFD) SHALL BE INVERTER DUTY MOTORS DESIGNED ACCORDING TO THE REQUIREMENTS OF NEMA MG 1, PART 31, “DEFINITE PURPOSE, INVERTER FED MOTORS”AND SHALL BE COMPATIBLE WITH THE PARTICULAR MANUFACTURER’S DRIVE THAT IS USED. 11.COORDINATE WITH THE ELECTRICAL DRAWINGS FOR THE REQUIRED SHORT CIRCUIT CURRENT RATING OF THE PANELBOARD SERVING THE EQUIPMENT. THE EQUIPMENT NAMEPLATE SHALL BEAR A RATING OF NO LESS THAN THE PANELBOARD RATING. DUCT SMOKE DETECTORS: 1.ALL FANS SUPPLYING MORE THAN 2000 CFM OF AIR TO ANY SPACE SHALL BE INSTALLED WITH A SMOKE DETECTOR IN THE RETURN DUCTWORK.DUCT SMOKE DETECTORS SHALL BE INSTALLED IN THE RETURN AIR PATH OF AIR DISTRIBUTION SYSTEMS UTILIZING A COMMON SUPPLY AND/OR RETURN AIR PLENUM WITH A COMBINED DESIGN CAPACITY GREATER THAN 2000 CFM. 2.THE SMOKE DETECTOR SHALL BE WIRED TO STOP THE FAN UPON DETECTION OF SMOKE, AND SIGNAL THE BUILDING FIRE ALARM CONTROL PANEL. THE SMOKE DETECTOR SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, MOUNTED IN THE DUCT BY THE MECHANICAL CONTRACTOR, AND WIRED BY THE ELECTRICAL CONTRACTOR. AIR DISTRIBUTION: 1.SUPPLY, RETURN AND O.A. DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEETMETAL IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS- METAL AND FLEXIBLE, LATEST EDITION AND IMC CHAPTER 6 AS REQUIRED. a.SNAP-LOCK LONGITUDINAL SEAMS ARE NOT ALLOWED UNLESS SECURED WITH SHEET METAL FASTENING SCREWS AS RECOMMENDED BY SMACNA. b.LEASING, AMENITY AND COMMON AREA DUCTWORK IN MULTIFAMILY PROJECTS SHALL HAVE SHEET METAL DUCTWORK. 2.TAPES, SEALANTS AND MASTICS USED TO SEAL METALLIC AND FLEXIBLE AIR DUCTS AND FLEXIBLE AIR CONNECTORS SHALL COMPLY WITH UL 181B AND SHALL BE MARKED “181 B-FX”FOR PRESSURE-SENSITIVE TAPE OR “181 B-M”FOR MASTIC/SEALANT. 3.SEAL THE ANNULAR SPACE AROUND ALL DUCT PENETRATIONS THROUGH WALLS, CEILINGS AND FLOORS AIRTIGHT WITH AN APPROVED MATERIAL (RE: ARCHITECTURAL DRAWINGS FOR APPROVED MATERIALS). 4.MECHANICAL FASTENERS FOR USE WITH FLEXIBLE NONMETALLIC AIR DUCTS SHALL COMPLY WITH UL 181B AND SHALL BE MARKED “181 B-C”. 5.SHEETMETAL DUCT SEALING: a.ALL JOINTS AND SEAMS IN ALL SHEETMETAL DUCTWORK SHALL BE SEALED WITH DUCT SEALER. b.SEAL, INSPECT AND TEST SHEETMETAL DUCTWORK PRIOR TO INSULATING OR CONCEALING. SEAL ALL DUCTWORK AND PLENUMS TO MEET SMACNA SEAL CLASS A. c.SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, AND DUCT WALL PENETRATIONS. d.PRESSURE-SENSITIVE TAPE SHALL NOT BE USED AS THE PRIMARY SEALANT, UNLESS IT HAS BEEN CERTIFIED TO COMPLY WITH UL-181A OR UL-181B BY AN INDEPENDENT TESTING LABORATORY AND THE TAPE IS USED IN ACCORDANCE WITH THAT CERTIFICATION. e.ALL CONNECTIONS SHALL BE SEALED, INCLUDING BUT NOT LIMITED TO SPIN-IN FITTINGS, TAPS, OTHER BRANCH CONNECTIONS, ACCESS DOORS, AND DUCT CONNECTIONS TO EQUIPMENT. f.SEALING THAT WOULD VOID PRODUCT LISTINGS IS NOT REQUIRED. g.SPIRAL LOCK SEAMS NEED NOT BE SEALED. 6.ALTERNATE SUPPLY AND RETURN AIR DUCTWORK FOR DWELLING UNITS -FIBERGLASS DUCT BOARD (MINIMUM INSULATION VALUE R-4.3 WHERE LOCATED WITHIN THE THERMAL ENVELOPE AND A MINIMUM INSULATION VALUE OF R-8 WHEN LOCATED IN AN ATTIC OR OUTSIDE THE THERMAL ENVELOPE OF THE BUILDING, OR GREATER WHERE REQUIRED BY APPLICABLE ENERGY CODE) WITH GLASS FABRIC REINFORCED VAPOR BARRIER. DUCT CONSTRUCTION SHALL CONFORM TO SMACNA FIBROUS GLASS DUCT CONSTRUCTION STANDARDS, LATEST EDITION. FIBERGLASS DUCTBOARD SHALL BE UL 181 LISTED AS A CLASS 1 RIGID AIR DUCT. ALL FIBERGLASS DUCTWORK AND ACCESSORIES SHALL BE FABRICATED BY A MANUFACTURER'S AUTHORIZED FABRICATOR, SHALL BE INSTALLED WITH THE FABRICATOR'S SUPERVISION AND IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. FIBERGLASS DUCTWORK SHALL NOT BE USED OUTDOORS. DUCT BOARD SHALL BE JOHNS MANVILLE MICRO-AIRE OR EQUAL. a.TAPES AND MASTICS USED TO SEAL FIBROUS GLASS DUCTWORK SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A AND SHALL BE MARKED “181 A-P”FOR PRESSURE-SENSITIVE TAPE, “181 A-M”FOR MASTIC OR “181 A-H”FOR HEAT-SENSITIVE TAPE. 7.EXTERIOR SUPPLY AND RETURN DUCTWORK SHALL BE CONSTRUCTED OF GALVANIZED SHEETMETAL (G 90 MINIMUM) WITH ALL SEAMS CAULKED AND SEALED WEATHERTIGHT AND COATED WITH A RUST PREVENTIVE COATING OVER THE ENTIRE DUCT SURFACE. RUST PREVENTATIVE COATING SHALL BE “RUST DESTROYER”BY ADVANCE PROTECTIVE PRODUCTS, INC., OR APPROVED EQUAL. SLOPE OR CROWN DUCTWORK AT 1/4”PER FOOT TRANSVERSELY TO PREVENT STANDING WATER ON TOP OF DUCTWORK. ALSO, REFER TO INSULATION NOTE 1e BELOW FOR INSULATION REQUIREMENTS. 8.ALL OPEN-ENDED DUCTS AND FAN OUTLETS SHALL HAVE ½”X ½”HARDWARE CLOTH (WMS) AFFIXED TO THE OPENING. 9.EXHAUST DUCTWORK SHALL BE GALVANIZED SHEET METAL (G 90 MINIMUM) CONSTRUCTED TO SMACNA STANDARDS AND SHALL NOT BE INSULATED UNLESS NOTED OTHERWISE. 10.ALL DUCTWORK SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. DUCT SUPPORTS AND ATTACHMENT TO STRUCTURE SHALL BE PER SMACNA STANDARDS. 11.FLEXIBLE DUCTWORK SHALL BE THERMAFLEX M-KE (U.L. 181 LISTED, CLASS 1 FLEXIBLE AIR DUCT) OR EQUAL BY FLEXMASTER, QUIETFLEX, ATCO, JM LAMBORN, OR ROYAL METAL PRODUCTS. PROVIDE A MINIMUM INSULATION VALUE OF R-6; R-8 WHEN LOCATED OUTSIDE THE THERMAL ENVELOPE OF THE BUILDING, OR GREATER WHERE REQUIRED BY APPLICABLE ENERGY CODE. AIR CONNECTORS ARE NOT ACCEPTABLE. FLEX DUCT DIAMETER SHALL MATCH DEVICE NECK DIAMETER. PROVIDE ROUND GALVANIZED STEEL DUCT RUNOUTS TO MAINTAIN A MAXIMUM FLEXIBLE DUCT LENGTH OF 8'-0" (EXCEPT IN DWELLING UNITS, LENGTH SHALL BE AS INDICATED). LEASING, AMENITY AND COMMON AREAS IN MULTIFAMILY PROJECTS SHALL BE LIMITED TO 8’-0”MAXIMUM FLEXIBLE DUCT LENGTH. FLEXIBLE DUCTWORK SHALL BE INSTALLED AS STRAIGHT AS POSSIBLE AND SHALL BE ROUTED AND SUPPORTED WITHOUT FORMING CRIMPS OR OTHER AIR FLOW RESTRICTIONS. PROVIDE SQUARE TO ROUND ADAPTERS OR BOOTS TO CONNECT TO AIR DEVICE NECK WHEN REQUIRED. 12.COMMON AREA ROUND AND FLEXIBLE SUPPLY AIR DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH A CONICAL TYPE SPIN-IN FITTING WITH MANUAL VOLUME DAMPER (EXCEPT WHERE INSTALLED ABOVE INACCESSIBLE CEILINGS, THE DAMPER SHALL BE OMITTED AND PROVIDED IN THE AIR DEVICE NECK). 13.DWELLING UNIT ROUND AND FLEXIBLE SUPPLY AIR DUCTWORK SHALL BE CONNECTED TO MAIN DUCTS WITH A TAB TYPE FITTING. 14.TAPE, BED AND SEAL AIR-TIGHT ALL PENETRATIONS FROM RETURN AIR PLENUMS TO NON-RETURN AIR PLENUMS THAT ARE REQUIRED DUE TO DUCTWORK, PIPING OR OTHER ITEMS. 15.DUCTWORK DIMENSIONS SHOWN ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. 16.EXTERNAL STATIC PRESSURE (ESP) DOES NOT INCLUDE COIL, CASING OR FILTER PRESSURE DROP. 17.INSTALL FIRE, SMOKE, COMBINATION FIRE/SMOKE, AND CEILING RADIATION DAMPERS IN ACCORDANCE WITH MANUFACTURER’S UL INSTALLATION INSTRUCTIONS AND SMACNA’S FIRE, SMOKE AND RADIATION DAMPER INSTALLATION GUIDE FOR HVAC SYSTEMS. 18.INSTALL FIRE DAMPERS IN ALL RATED WALLS AND FLOOR PENETRATIONS. FIRE DAMPERS SHALL BE THE DYNAMIC TYPE WITH BLADES OUT OF THE AIRSTREAM WHERE POSSIBLE. ALL FIRE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF U.L. 555. 19.INSTALL SMOKE DAMPERS IN ALL DUCT PENETRATIONS THROUGH SMOKE RATED WALLS. WHERE DUCTS PENETRATE WALLS THAT CARRY BOTH FIRE AND SMOKE RATINGS OR ARCHITECTURAL SHAFTS, THE DAMPERS INSTALLED SHALL BE COMBINATION FIRE AND SMOKE DAMPERS. ALL SMOKE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF U.L. 555S. ALL COMBINATION FIRE AND SMOKE DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF U.L. 555 AND U.L. 555S. POWER WIRING TO TEST SWITCH AND ACTUATOR SHALL BE PER MANUFACTURER’S INSTALLATION INSTRUCTIONS. 20.INSTALL CEILING RADIATION DAMPERS IN ALL MEMBRANE PENETRATIONS OF FIRE RATED FLOOR/CEILING AND ROOF/CEILING ASSEMBLIES WHERE NOT OTHERWISE PROTECTED WITH A RATED SHAFT. ALL CEILING RADIATION DAMPERS SHALL COMPLY WITH THE REQUIREMENTS OF U.L. 555C. REFER TO THE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF RATED ASSEMBLIES. WHERE NECESSARY, PROVIDE DUCT ACCESS DOOR AND CEILING ACCESS PANEL. 21.DUCT ACCESS DOORS: PROVIDE ACCESS DOORS IN DUCTWORK AT EACH FIRE, COMBINATION FIRE/SMOKE AND SMOKE DAMPER LOCATION. 22.PROVIDE ALL OUTDOOR AIR INTAKES AND EXHAUST OPENINGS WITH MOTORIZED OR GRAVITY DAMPERS IN ACCORDANCE WITH THE LOCAL ENERGY CODE. DAMPERS SHALL CLOSE WHEN THE VENTILATION SYSTEM IS NOT OPERATING. 23.LOCATIONS OF GRILLES, REGISTERS, AND DIFFUSERS SHOWN ON THE DRAWINGS ARE APPROXIMATE. COORDINATE EXACT LOCATIONS WITH LIGHTS, CEILING GRID, ETC. AND ARCHITECTURAL REFLECTED CEILING PLAN. 24.WHERE BALANCING DAMPERS CANNOT BE ACCESSED FROM BELOW THE CEILING, PROVIDE A REMOTE OPERATED ELECTRONIC DAMPER; YOUNG REGULATOR OR EQUAL. 25.DUCTWORK CONNECTING KITCHEN EXHAUST HOODS TO EXHAUST FANS SHALL BE CONSTRUCTED OF 16 GAUGE BLACK STEEL WITH WELDED SEAMS OR SHALL BE A UL TESTED AND LISTED FACTORY BUILT GREASE DUCT SYSTEM (RE: SPEC SECTION 23 09 00). ALL GREASE EXHAUST DUCTWORK SHALL BE CONSTRUCTED AND INSTALLED PER THE REQUIREMENTS OF LOCAL CODE AUTHORITIES AND NFPA 96 REQUIREMENTS (FACTORY BUILT GREASE DUCT SYSTEMS SHALL BE INSTALLED PER MANUFACTURER’S INSTALLATION INSTRUCTIONS). INSTALL GASKETED ACCESS DOORS AT 20’ON CENTER AND AT EACH CHANGE OF DIRECTION. ACCESS DOORS IN VERTICAL DUCT RUNS SHALL BE LOCATED 12”AFF IN A COMMON AREA (NOT WITHIN DWELLING UNITS). 26.DISHWASHER EXHAUST DUCTWORK ABOVE THE CEILING SHALL BE EITHER 18-GAUGE STAINLESS STEEL OR 16-GAUGE ALUMINUM. ALL SEAMS AND JOINTS SHALL BE WELDED LIQUID-TIGHT. DISHWASHER EXHAUST RISERS AND TRIM COLLARS BELOW THE CEILING SHALL BE 18-GAUGE, TYPE 304 STAINLESS STEEL FINISHED IN A 180 GRIT POLISHED FINISH. ALL DISHWASHER EXHAUST DUCTWORK SHALL SLOPE DOWN TOWARD THE DISHWASHER CONNECTIONS AT 1/4" PER FOOT AND BE CONSTRUCTED WITH NO POCKETS WHICH WILL TRAP CONDENSATION. 27.SUPPLY AND EXHAUST DUCTWORK SERVING SWIMMING POOLS AND POOL EQUIPMENT/CHEMICAL STORAGE ROOMS SHALL BE 16-GAUGE ALUMINUM (ALLOY 3003 -H14 TEMPER PER ASTM B209). SLOPE DUCTWORK AT 1/8" PER FOOT TOWARDS DRAIN. 28.DUCTWORK INSTALLED WITHIN OPEN ATTIC SPACES SHALL BE GALVANIZED STEEL. DUCTBOARD AND FLEX DUCT IS ALLOWABLE WHERE SERVING DWELLING UNIT SUPPLY AIR SYSTEMS. 29.FLEXIBLE DUCT CONNECTORS SHALL BE USED TO CONNECT DUCTWORK AND PLENUMS TO FAN-ROTATING EQUIPMENT; PROFLEX BY DUCTMATE OR APPROVED EQUAL. INDOOR FLEXIBLE CONNECTORS SHALL BE 26 OZ/SQ. YD. GLASS FABRIC DOUBLE COATED WITH NEOPRENE. OUTDOOR FLEXIBLE CONNECTORS SHALL BE 24 OZ/SQ. YD. GLASS FABRIC DOUBLE COATED WITH WEATHERPROOF SYNTHETIC RUBBER RESISTANT TO UV RAYS AND OZONE. FABRICS, COATINGS AND ADHESIVES SHALL BE TESTED IN ACCORDANCE WITH UL 701 AND HAVE A FLAME SPREAD/ SMOKE DEVELOPED RATING OF 25/50. FLEXIBLE DUCT CONNECTORS SHALL ALSO BE PROVIDED WHERE DUCTWORK CROSSES BUILDING EXPANSION JOINTS. 30.EXPOSED INTERIOR DUCTWORK TO BE PAINTED SHALL HAVE ALL EXPOSED SURFACES (INCLUDING HANGER STRAPS) COATED WITH A "PAINT GRIP" FINISH FOR FIELD PAINTING. AS AN OPTION, MILL PHOSPHATIZED STEEL DUCTWORK MAY BE USED. LINE OR INSULATE PER HVAC GENERAL NOTES OR SPEC SECTION 23 07 00. 31.PROTECT DUCTS EXPOSED IN FINISHED SPACES FROM BEING DENTED, SCRATCHED, OR DAMAGED. TRIM DUCT SEALANTS FLUSH WITH METAL TO CREATE A SMOOTH AND UNIFORM EXPOSED BEAD. TWO-PART TAPE SEALING SYSTEMS ARE NOT ALLOWED. REPAIR OR REPLACE DAMAGED DUCTWORK AND FINISH WORK THAT DOES NOT COMPLY WITH THESE REQUIREMENTS. 32.SUPPORT ROOF MOUNTED DUCTWORK AT 6 FT. OC (MAX.) WITH MIFAB SERIES DSA DUCT SUPPORT SYSTEM. UV RESISTANT RUBBER BASES SHALL BE PLACED ON ROOFING WALKPAD MATERIAL. COORDINATE WITH ROOFING INSTALLER. 33.INSTALL DUCTWORK SUCH THAT LINE-OF-SIGHT IS ELIMINATED BETWEEN RETURN AIR REGISTERS/GRILLES AND AIR HANDLING UNITS, FAN COIL UNITS AND ROOFTOP UNITS. INSULATION: 1. DUCT INSULATION: a. DUCT WRAP SHALL BE UL LISTED FIBERGLASS BLANKET INSULATION WITH FOIL VAPOR BARRIER, JOHNS MANVILLE MICROLITE EQ FSK OR APPROVED EQUAL. PUNCTURES AND TEARS IN THE FOIL JACKET SHALL BE PATCHED WITH FOIL TAPE TO MAINTAIN THE INTEGRITY OF THE VAPOR BARRIER. INSULATE SHEET METAL DUCTWORK IN THE THICKNESSES AND DENSITIES LISTED BELOW: 1. SHEET METAL SUPPLY AND OUTSIDE AIR DUCTWORK: 2”THICK, 1 LB/FT3 DENSITY, R-6 MINIMUM INSTALLED. 2. SHEET METAL RETURN DUCTWORK IN NON-AIR-CONDITIONED AREAS (SUCH AS INTERSTITIAL SPACES AND FLOOR/CEILING ASSEMBLIES): 2" THICK, 1 LB/FT3 DENSITY, R-6 MINIMUM INSTALLED. 3. ALL SHEET METAL DUCTWORK LOCATED OUTSIDE OF THE THERMAL ENVELOPE OF THE BUILDING (INCLUDING CRAWL SPACES AND ATTIC SPACES): 3”THICK, ¾" LB/FT3 DENSITY, R-8 MINIMUM INSTALLE. b. INDOOR EXPOSED RECTANGULAR SHEET METAL SUPPLY AND RETURN AIR DUCTWORK SHALL BE LINED WITH 1”THICK DUCT LINER (MINIMUM R-4) JOHNS MANVILLE LINACOUSTIC RC OR EQUAL. c. INDOOR EXPOSED ROUND, SPIRAL AND OVAL SUPPLY AND RETURN AIR DUCT SHALL BE LINED WITH 1”THICK ROUND DUCT LINER (MINIMUM R-4), JOHNS MANVILLE SPIRACOUSTIC PLUS OR EQUAL. d. INDOOR EXPOSED ROUND AND SPIRAL OUTSIDE AIR DUCT SHALL BE INSULATED WITH 1”THICK PREFORMED FIBROUS GLASS PIPE INSULATION WITH VAPOR BARRIER JACKET [K-VALUE NOT TO EXCEED 0.23 BTU·in/hr·ft²·°F (0.033 W/m K) WHEN TESTED IN ACCORDANCE WITH ASTM C 335 at 75°F (24°C)]; JOHNS MANVILLE MICRO-LOK OR APPROVED EQUAL. e. EXTERIOR DUCTWORK SHALL BE LINED WITH 2”THICK DUCT LINER BOARD (MINIMUM R-8. JOHNS MANVILLE PERMACOTEâ LINACOUSTIC R-300 OR EQUAL. COAT THE EXTERIOR OF THE ENTIRE DUCT SURFACE WITH A RUST INHIBITIVE PAINT. PAINTING BY MECHANICAL. SUBMIT COLOR CHART TO THE ARCHITECT DURING THE SUBMITTAL PHASE. ALTERNATE EXTERNAL INSULATION SYSTEMS: 1) THERMADUCT OUTDOOR DUCT SYSTEM HAVING A MINIMUM R-VALUE OF 8. THE SYSTEM SHALL UTILIZE NON-FIBROUS CLOSED CELL KINGSPAN KOOLDUCT FORTIFIED INNER LINER COMPLIANT TO UL (C-UL) 181, STANDARD FOR SAFETY LISTED, CLASS 1 SYSTEM AND SMACNA CLASS 1 LEAKAGE, OR LESS. SUBMIT PRODUCT DATA AND LAYOUT DRAWINGS DURING THE SUBMITTAL PHASE. FOR PROJECTS LOCATED WITHIN 2 MILES OF THE SEACOAST, FLANGES AND HARDWARE SHALL BE ALUMINUM (ALLOY 3003 -H14 TEMPER PER ASTM B209); 2) SHEET METAL DUCTWORK WITH CLASS B FOIL FACED POLYISOCYANURATE FOAM INSULATION HAVING A MINIMUM R-VALUE OF 8 TO THE EXTERIOR WITH WEATHER RESISTANT WHITE FLEXIBLE CLADDING, ALUMAGUARD LITE WHITE BY POLYGUARD. INSTALL IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTIONS; 3) SHEET METAL DUCTWORK WITH PHYSICALLY CROSSLINKED CLOSED CELL POLYOLEFIN FOAM INSULATION HAVING A MINIMUM R-VALUE OF 8 WITH FACTORY APPLIED HEAVY DUTY MULTILAYER COMPOSITE FOIL FACING WITH A UV AND WEATHER DURABLE COATING; THERMOBREAK NO-CLAD INSULATION BY SEKISUI VOLTEK. INSTALL IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTIONS. CROWN OR SLOPE DUCTWORK AT 1/4”PER FOOT TRANSVERSELY TO PREVENT STANDING WATER ON TOP OF DUCTWORK. f.KITCHEN HOOD EXHAUST DUCTWORK SHALL BE INSULATED, WHERE REQUIRED, PER NFPA 96 AND LOCAL CODE REQUIREMENTS. KITCHEN HOOD SUPPLY DUCTWORK SHALL BE INSULATED AS SPECIFIED FOR HVAC SUPPLY DUCTWORK. EXPOSED DUCT WRAP INSULATION SYSTEMS SHALL BE PROTECTED WHERE SUBJECT TO PHYSICAL DAMAGE. g.DUCT LINER FOR ACOUSTICS: LINE ALL SUPPLY AND RETURN SHEETMETAL DUCTWORK A MINIMUM OF 15'-0" (OR AS INDICATED OR SPECIFIED HEREIN) UPSTREAM AND DOWNSTREAM OF ALL AIR HANDLING UNITS AND ROOFTOP UNITS, DUCT LINER FOR RECTANGULAR DUCTS SHALL BE 1½”THICK, (MINIMUM R-6 OR GREATER WHERE REQUIRED BY APPLICABLE ENERGY CODE) [3" THICK (MINIMUM R-12)]; JOHNS MANVILLE LINACOUSTIC RC OR EQUAL. 1. THE LEADING EDGE OF THE DUCT LINER SHALL HAVE A SHEETMETAL NOSING. 2. EXPOSED EDGES AND BUTT JOINTS SHALL BE “BUTTERED”WITH DUCT SEALER. 3. LINED DUCTWORK DOES NOT REQUIRE ADDITIONAL EXTERIOR INSULATION WHERE LINER MEETS REQUIRED R-VALUES. 4. RETURN AIR TRANSFER DUCTS, ELBOWS AND SOUND BOOTS SHALL BE LINED WITH 1”THICK LINER UNLESS OTHERWISE NOTED. 5. DUCT LINER SHALL BE INTERRUPTED AT ALL FIRE, SMOKE, COMBINATION FIRE/SMOKE AND RADIATION DAMPERS. 6. DUCT LINER SHALL BE INTERRUPTED NOT LESS THAN 6" UPSTREAM AND 6" DOWNSTREAM OF ELECTRIC-RESISTANCE AND FUEL-BURNING HEATERS IN A DUCT SYSTEM. a. REFER TO ARCHITECTURAL DRAWINGS AND/OR SPECIFICATIONS FOR PAINTING OF DUCTWORK, INSULATION, ETC. IN EXPOSED INTERIOR AREAS. b. DUCTWORK PENETRATING SMOKEPROOF ENCLOSURES SHALL BE WRAPPED USING A U.L. LISTED AND APPROVED 2-HOUR RATED FIRE WRAP INSULATING SYSTEM OR ENCLOSED IN AN APPROVED FIRE RATED ASSEMBLY. 2.PIPE INSULATION: a. CONVENTIONAL SPLIT SYSTEMS –REFRIGERANT PIPING INSTALLED OUTDOORS SHALL BE INSULATED WITH FLEXIBLE ELASTOMERIC TUBING WITH FACTORY APPLIED UV RESISTANT DURABLE PROTECTIVE JACKET, ARMAFLEX SHIELDTM (K FACTOR 0.25 BTU·IN/HR·FT²·°F) CONTINUOUS COIL PIPE INSULATION AS MANUFACTURED BY ARMACELL, LLC OR ALTERNATES LISTED BELOW, WHEN THE PRODUCT IS AVAILABLE IN THE REQUIRED PIPE SIZE AND INSULATION WALL THICKNESS. NO FIELD APPLIED PROTECTIVE COATING OR FINISH SHALL BE USED WITH THIS INSULATION. LONGITUDINAL AND BUTT JOINTS SHALL BE SEALED PER MANUFACTURER’S INSTALLATION INSTRUCTIONS. POLYETHYLENE FOAM INSULATION IS NOT ACCEPTABLE. ACCEPTABLE ALTERNATE ELASTOMERIC PRODUCT: 1)K-FLEX USA; K-FLEX TITANTM (K-FACTOR: 0.245 HR•FT²•°F/BTU (0.035 M²•°C/W) AT 75°F (24°C) MEAN TEMPERATURE). 2)MUELLER STREAMLINE DURAGUARD UV (K-FACTOR: 0.245 HR•FT²•°F/BTU (0.035 M²•°C/W) AT 75°F (24°C) MEAN TEMPERATURE). b.REFRIGERANT PIPING INSTALLED INDOORS: SHALL BE INSULATED WITH FLEXIBLE ELASTOMERIC TUBING INSULATION, AP/ARMAFLEX BLACK LAPSEALTM PIPE INSULATION AS MANUFACTURED BY ARMACELL, LLC OR ALTERNATES LISTED BELOW. ALL JOINTS AND SEAMS SHALL BE SEALED WEATHERTIGHT WITH ARMAFLEX BLACK LAPSEALTM TAPE. BLACK LAPSEALTM TAPE SHALL ALSO BE USED TO SECURE THE THERMOSTAT CABLE TO THE PIPE INSULATION. AS AN ALTERNATE TO INSULATION PRODUCTS WITH THE UV RESISTANT DURABLE PROTECTIVE JACKET NOTED ABOVE, ARMAFLEX BLACK LAPSEAL INSULATION MAY BE USED OUTDOORS WITH A FIELD APPLIED UV RESISTANT FINISH COAT. THE FINISH COAT SHALL BE TWO COATS OF A WATER-BASED LATEX PAINT DESIGNED FOR USE OVER ALL FORMS OF FLEXIBLE ELASTOMERIC INSULATION. FINISH COAT SHALL PROVIDE A PROTECTIVE FINISH SUITABLE FOR OUTDOOR APPLICATIONS, FORMULATED FOR COLD WEATHER FLEXIBILITY TO RESIST CRACKING AND WEATHER-RESISTANT TO ULTRAVIOLET (UV) AND OZONE. COATING SHALL BE ARMAFLEX WB FINISH OR EQUIVALENT PRODUCT COMPATIBLE WITH THE INSULATION. POLYETHYLENE FOAM INSULATION IS NOT ACCEPTABLE. ACCEPTABLE ALTERNATE PRODUCTS: 1)AEROFLEX, USA, INC.; AEROCELL-SSPTTM (K-FACTOR: 0.245 HR•FT²•°F/BTU (0.035 M²•°C/W) AT 75°F (24°C) MEAN TEMPERATURE) WITH PROTAPE AND TWO COATS OF FIELD APPLIED AEROCEL AEROCOAT. (AEROCEL AEROCOAT REQUIRED FOR OUTDOOR INSTALLATION ONLY). 2)K-FLEX USA, LLC., K-FLEX INSUL-LOCK DS (K-FACTOR: 0.245 HR•FT²•°F/BTU (0.035 M²•°C/W) AT 75°F (24°C) MEAN TEMPERATURE) (INDOOR USE ONLY). 3)MUELLER STREAMLINE ELASTOMERIC INSULATION (K-FACTOR: 0.245 HR•FT²•°F/BTU (0.035 M²•°C/W) AT 75°F (24°C) MEAN TEMPERATURE) (INDOOR USE ONLY). c.INSULATION THICKNESS SHALL BE [PER SPECIFICATION SECTION 23 23 00. d.INSULATE ALL CONDENSATE DRAIN PIPING AND FITTINGS WITHIN THE BUILDING’S THERMAL ENVELOPE WITH SECTIONAL PREFORMED FIBERGLASS PIPE INSULATION (K FACTOR NOT TO EXCEED 0.23 BTU·IN/HR·FT²·°F) WITH VAPOR BARRIER JACKET; JOHNS MANVILLE MICRO-LOK OR APPROVED EQUAL. ACCEPTABLE ALTERNATE: CLOSED CELL ELASTOMERIC; AP ARMAFLEX WITH LAP SEAL. THICKNESS SHALL BE MANUFACTURER’S RECOMMENDED THICKNESS TO PREVENT CONDENSATION ON THE EXTERIOR OF THE JACKET; MINIMUM THICKNESS SHALL BE ½" FOR PIPE SIZES UP TO AND INCLUDING 1¼“AND 1”THICKNESS FOR PIPE SIZES 1½“AND LARGER. INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER’S INSTALLATION INSTRUCTIONS. GAS FLUES (U.L. LISTED): 1. GAS FLUE MATERIAL SHALL BE AS RECOMMENDED BY THE HEATING APPLIANCE MANUFACTURER EXCEPT THAT WHERE POLYVINYL CHLORIDE (PVC) IS ALLOWABLE FOR CATEGORY II AND IV APPLIANCES, PROVIDE A UL TESTED AND LISTED POLYPROPYLENE (PP) GAS VENTING SYSTEM; POLYFLUE, POLYPRO, INNOFLUE OR APPROVED EQUAL. PVC IS ACCEPTABLE FOR COMBUSTION AIR PIPING. CERTAIN APPLIANCES MAY REQUIRE AL29-4C VENTING MATERIAL IN CONFORMANCE WITH UL 1738. 2.SIZING AND ROUTING RESTRICTIONS SHALL BE PER MANUFACTURER’S REQUIREMENTS. 3.TERMINATE ALL GAS FLUE PIPING TO THE OUTDOORS THROUGH ROOF OR EXTERIOR WALL. TERMINATION SHALL BE INSTALLED PER MANUFACTURER’S REQUIREMENTS AND FLASHED AND SEALED WEATHERTIGHT. SMOKE CONTROL SYSTEMS: 1. ALL FANS, DAMPERS, AND OTHER HVAC EQUIPMENT THAT ARE PART OF A SMOKE CONTROL SYSTEM SHALL BE MONITORED AND CONTROLLED BY A U.L. LISTED FIRE FIGHTERS’SMOKE CONTROL STATION (FSCS) IN ACCORDANCE WITH NFPA 92. THE FSCS SHALL BE MANUFACTURED BY SIEMENS, HONEYWELL, NOTIFIER, JOHNSON CONTROLS OR APPROVED EQUAL. THE FSCS SIZE AND CAPACITY SHALL BE AS REQUIRED BY THE NUMBER OF SMOKE CONTROL POINTS. THE STATION SHALL BE LOCATED IN THE FIRE COMMAND CENTER. THE FSCS SHALL COMPLY WITH BUILDING CODE REQUIREMENTS AND NFPA 92 GUIDELINES. 2.STAIR PRESSURIZATION FANS SHALL BE PROVIDED WITH A DUCT SMOKE DETECTOR IN THE AIRSTREAM TO DE-ENERGIZE THE FAN UPON DETECTION OF SMOKE. A RED INDICATOR, WITH RESET SWITCH, LABELED “SMOKE DETECTOR TRIP”SHALL BE LOCATED ON THE FACE OF THE FIREFIGHTER’S SMOKE CONTROL PANEL ADJACENT TO THE FAN’S MANUAL OVERRIDE SWITCH. THE DUCT DETECTOR SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR, MOUNTED BY THE MECHANICAL CONTRACTOR AND WIRED BY THE ELECTRICAL CONTRACTOR. 3.STAIR PRESSURIZATION FANS SHALL BE PROVIDED WITH A CLASS I SMOKE DAMPER ON THE INLET OF THE FAN. DAMPER SHALL BE NORMALLY OPEN (POWERED CLOSED/FAIL OPEN). FOR PRESSURIZATION SYSTEMS, THE SMOKE DAMPER IS BEING USED AS A CONTROL DAMPER TO REDUCE STAIRWELL/HOISTWAY HEAT LOSS AND PREVENT FANS FROM “FREE-WHEELING”. DAMPER SHALL BE FULLY OPEN PRIOR TO ENERGIZING FAN. ON THE INLET SIDE OF ROOF MOUNTED FANS, PROVIDE A 45° WEATHER COWL WITH 1’X1”GALVANIZED STEEL SCREEN COVERING THE ENTIRE INLET. 4.SMOKE CONTROL FANS SHALL BE UL LISTED –POWER VENTILATORS FOR SMOKE CONTROL SYSTEMS AND INCLUDE, BUT NOT LIMITED TO, A HIGH TEMPERATURE OPTION (500ºF FOR A MINIMUM OF FOUR HOURS, AND 1000ºF FOR A MINIMUM OF FIFTEEN MINUTES), DRIVE COMPONENTS SIZED FOR A MINIMUM OF 150% OF THE DRIVEN LOAD AND A MINIMUM OF TWO HEAT RESISTANT BELTS WITHIN A PROTECTIVE BELT TUBE. 5.SMOKE CONTROL SYSTEMS ARE TO BE TESTED AND CERTIFIED BY A 3RD PARTY SPECIAL INSPECTOR UNDER CONTRACT WITH THE OWNER. REFER TO PROJECT SPECIFICATIONS FOR ADDITIONAL INFORMATION. PIPING: 1. REFRIGERANT PIPING SHALL BE TYPE L OR ACR (AIR CONDITIONING AND REFRIGERATION FIELD SERVICE) COPPER TUBING WITH BRAZED JOINTS. 2.REFRIGERANT CIRCUIT ACCESS PORTS LOCATED OUTDOORS SHALL BE FITTED WITH LOCKING-TYPE TAMPER-RESISTANT CAPS. 3.SEAL THE ANNULAR SPACE AROUND ALL PIPING PENETRATIONS THROUGH WALLS, CEILINGS AND FLOORS AIRTIGHT WITH AN APPROVED MATERIAL (RE: ARCHITECTURAL DRAWINGS FOR APPROVED MATERIALS). 4.CONDENSATE FROM ALL AIR CONDITIONING EQUIPMENT SHALL BE TRAPPED AND ROUTED TO THE NEAREST PLUMBING DRAIN]. CONDENSATE PIPING SHALL BE INSULATED TYPE M COPPER OR INSULATED SCHEDULE 40 PVC (IN HVAC PLENUMS USE INSULATED TYPE M COPPER). CPVC PIPING IS NOT ALLOWED. CONDENSATE SHALL BE PUMPED AS REQUIRED. CONDENSATE PUMP SHALL BE TESTED TO COMPLY WITH UL 2043 FOR PLENUM APPLICATIONS; LITTLE GIANT VCCA SERIES. (PVC EXPOSED TO THE WEATHER SHALL BE PAINTED WITH A LIGHT-COLORED ACRYLIC OR LATEX ULTRAVIOLET (UV) AND OZONE INHIBITOR PAINT THAT IS CHEMICALLY COMPATIBLE WITH PVC. 5.PROVIDE MANUAL OR AUTOMATIC AIR VENT (WITH DRAIN) AT HIGH POINTS OF ALL RECIRCULATING WATER PIPING SYSTEMS. 6.PIPING AT PUMPS AND EQUIPMENT SHALL BE SUPPORTED SO THAT NO PIPING OR ACCESSORY LOAD IS CARRIED BY THE PUMP OR EQUIPMENT. 7.PIPE SUPPORTS AND HANGERS: a. ALL PIPING ABOVE GRADE SHALL BE SUPPORTED BY THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR CEILING STRUCTURE. PIPING HUNG FROM JOISTS SHALL BE HUNG FROM THE TOP CHORDS OF THE JOISTS. b. UNLESS NOTED OTHERWISE, CONDENSATE DRAIN AND REFRIGERANT PIPING ROUTED ON THE ROOF SHALL BE SUPPORTED WITH UV RESISTANT RUBBER SUPPORT SYSTEM; MIFAB C SERIES OR EQUAL BY DURA-BLOK. DWELLING UNITS: 1. SEAL ALL PENETRATIONS AIRTIGHT THRU WALLS, FLOORS AND CEILINGS, INCLUDING, BUT NOT LIMITED TO, ALL DUCTS, REGISTERS, GRILLES, RETURN AIR PLENUMS, OUTSIDE AIR AND EXHAUST DUCT PENETRATIONS AT THE EXTERIOR WALL, DRYER EXHAUST WALL BOXES (SEALED TO WALL), REFRIGERANT PIPING, CONDENSATE PIPING, CONTROL WIRING, CONDUIT, ETC. SEAL SEAMS OF GRILLES AND REGISTERS AIRTIGHT PRIOR TO INSTALLATION. 2.CLOTHES DRYER FLEXIBLE DUCTWORK SHALL BE CONNECTED (BY INSTALLING APPLIANCE CONTRACTOR) TO A MANUFACTURED DRYER WALL BOX (DRYERBOX MODEL 425 FOR UPWARD EXHAUST FLOW BY IN-O-VATE TECHNOLOGIES, INC. OR EQUAL). THE F AND T RATINGS FOR THE INSTALLATION SHALL BE 1 HOUR. THE FLEXIBLE DUCTWORK (BY DRYER INSTALLER) SHALL CONNECT THE CLOTHES DRYER TO THE DRYER WALL BOX CONNECTION USING A WORM DRIVE TYPE HOSE CLAMP AND BE INSTALLED AS SHOWN ON THE PLANS. THE LOCATION OF THE CLOTHES DRYER CONNECTION IN THE DWELLING UNIT SHALL BE BASED ON THE CLOTHES DRYER TYPE (STACKED OR SIDE BY SIDE) AND COORDINATED IN THE FIELD. 3.BATHROOM AND CLOTHES DRYER EXHAUST DUCTS PENETRATING A HORIZONTAL RATED ASSEMBLY THROUGH THE TOP PLATE OR BOTTOM PLATE OF A FRAMED WALL ASSEMBLY SHALL BE PER UL INSTALLATION INSTRUCTIONS. DUCTWORK SHALL BE CONSTRUCTED OF 26 GAUGE GALVANIZED STEEL FOR THE ENTIRE LENGTH OF THE DUCT SYSTEM. DUCTWORK SHALL BE INSTALLED WITH LONGITUDINAL SEAMS FACING UP. FROM THE EXTERIOR WALL INWARD, SLOPE THE LAST 10’OF DUCTWORK AT 1/8”/FT. DOWN TOWARDS THE EXTERIOR WALL. DO NOT SECURE DRYER DUCT WITH SHEET METAL SCREWS. 4.OUTSIDE AIR DUCTWORK SHALL BE CONSTRUCTED OF INSULATED 26 GAUGE GALVANIZED STEEL FOR THE ENTIRE LENGTH OF THE DUCT SYSTEM. FLEXIBLE DUCTWORK IS NOT PERMITTED. DUCTWORK SHALL BE INSTALLED WITH LONGITUDINAL SEAMS FACING UP. FROM THE EXTERIOR WALL INWARD, SLOPE THE LAST 10’OF DUCTWORK AT 1/8”/FT. DOWN TOWARDS THE EXTERIOR WALL. 5.BATHROOM (TOILET), KITCHEN AND CLOTHES DRYER EXHAUST DUCTWORK SHALL BE PROVIDED WITH A BACK DRAFT DAMPER. REFER TO DETAILS FOR ADDITIONAL INFORMATION. IF SCHEDULED OR DETAILED, BATHROOM AND KITCHEN EXHAUST TERMINATIONS SHALL INCLUDE AN INSECT SCREEN. 6.DWELLING UNIT KITCHEN RANGE HOODS SHALL BE THE VENTLESS RECIRCULATING TYPE AND WILL BE PROVIDED BY OTHERS. 7.BATHROOM (TOILET), AND CLOTHES DRYER EXHAUST DUCTWORK SHALL BE SHEET METAL WITH LONGITUDINAL SEAMS FACING UP. SEAMS SHALL BE SEALED AIRTIGHT WITH DUCT SEALER. 8.ABOVE CEILING ENCLOSED RETURN AIR PLENUMS SHALL BE SEALED AIRTIGHT. ALL PENETRATIONS SHALL BE SEALED WITH AN AIR-IMPERMEABLE SPRAY FOAM HAVING A 1-HOUR FIRE RATING AND A FLAME SPREAD/SMOKE DEVELOPMENT RATING OF 25/50. 9.AIR HANDLERS SHALL HAVE A MANUFACTURER’S DESIGNATION FOR AN AIR LEAKAGE OF NO MORE THAN 2% OF THE DESIGN AIR FLOW RATE WHEN TESTED IN ACCORDANCE WITH ASHRAE 193. 10.ALL JOINTS AND SEAMS OF REGISTERS, GRILLES AND DIFFUSER BOOTS, PANS, PLENUM BOXES, ETC. SHALL BE SEALED AIRTIGHT WITH DUCT SEALER OR MASTIC. VINYL OR FOIL TAPES ALONE ARE NOT ACCEPTABLE. REGISTER AND DIFFUSER BOOTS SHALL BE SEALED AIRTIGHT TO THE DRYWALL SURROUND. 11.TESTING AND BALANCING OF AIR DISTRIBUTION SYSTEMS SHALL BE PERFORMED AS NOTED IN THE TESTING AND BALANCING SECTION ABOVE. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:23:06 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM00.03 ALS SDW 2247601 SEQUENCES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV GENERAL 1. THERMOSTATS CONTROLLING EXHAUST FANS AND ELECTRIC HEATERS LOCATED IN A SAME ROOM SHALL BE CONFIGURED WITH MINIMUM A 10°F DEADBAND TO PREVENT SIMULTANEOUS COOLING AND HEATING. ALL OTHER THERMOSTATS THAT DO NOT REQUIRE MANUAL CHANGEOVER BETWEEN HEATING AND COOLING MODES SHALL BE CAPABLE OF PROVIDING A DEAD BAND OF AT LEAST 5°F WITHIN WHICH THE SUPPLY OF HEATING AND COOLING IS SHUT-OFF OR REDUCED TO A MINIMUM. 2. ALL THERMOSTATS SHALL HAVE AT LEAST A 5°F DEADBAND BETWEEN HEATING AND COOLING. 3. ALL THERMOSTATS SHALL HAVE CONTROLS THAT PREVENT SETPOINT OVERLAP. 4. ALL THERMOSTATS SHALL HAVE A BATTERY BACKUP THAT STORES THE TIME SCHEDULE PROGRAMMING FOR A MINIMUM OF 10 HOURS. 5. ALL THERMOSTATS SHALL HAVE THE CAPABILITY TO RESET THE ZONE TEMPERATURE SET POINT TO A MINIMUM OF 55 F AND A MAXIMUM OF 85 F. 6. WHERE CONDENSATE PUMPS ARE PROVIDED, INTERLOCK THE CONDENSATE PUMP SAFETY SWITCH TO SHUT DOWN THE ASSOCIATED UNIT UPON FAILURE OF THE CONDENSATE PUMP. ELECTRIC UNIT HEATERS (EUH): 1. ELECTRIC UNIT HEATERS SHALL BE CONTROLLED BY AN INTEGRAL THERMOSTAT TO MAINTAIN A SPACE TEMPERATURE SET POINT OF 50°F (ADJ.) FOR UNOCCUPIED SPACES OR 70°F (ADJ.) FOR OCCUPIED SPACES. ELECTRIC WALL HEATERS (EWH): 1. ELECTRIC WALL HEATERS SHALL BE CONTROLLED BY AN INTEGRAL THERMOSTAT TO MAINTAIN A SPACE TEMPERATURE SET POINT OF 50°F (ADJ.) FOR UNOCCUPIED SPACES OR 70°F (ADJ.) FOR OCCUPIED SPACES. VENTILATION FANS/ELECTRIC HEATERS 1. WHERE A VENTILATION FAN AND AN ELECTRIC HEATER ARE ISNTALLED IN THE SAME ROOM, PROVIDE A LINE VOLTAGE THERMOSTAT TO CONTROL THE FAN AND THE ELECTRIC HEATER. 2. THE FAN SHALL CYCLE TO MAINTAIN A COOLING SET POINT OF 80 DEG. F (ADJ.). THE INTAKE AND EXHAUST MOTORIZED DAMPERS (WHERE APPICABLE) SHALL BE INTERLOCKED WITH THE FAN. 3. THE HEATER SHALL CYCLE TO MAINTAIN A HEATING SET POINT OF 55 DEG. F (ADJ.). THE INTAKE AND EXHAUST MOTORIZED DAMPERS (WHERE APPLICABLE) SHALL BE CLOSED. 4. THERMOSTAT SHALL BE A 7-DAY PROGRAMMABLE AUTO CHANGEOVER THERMOSTAT. 5. PROVIDE A MINIMUM DEADBAND OF 5 DEG. F BETWEEN HEATING AND COOLING. 6. THERMOSTAT SHALL HAVE CONTROLS THAT PREVENT SET POINT OVERLAP. 7. THERMOSTAT SHALL HAVE A BATTERY BACKUP THAT STORES THE TIME SCHEDULE FOR A MINIMUM OF 10 HOURS. RESIDENTIAL TOILET ROOM EXHAUST FANS: 1. EXHAUST FANS SERVING RESIDENTIAL TOILET ROOMS SHALL BE ENERGIZED/DE-ENERGIZED VIA A WALL SWITCH. INDIVIDUAL TOILET ROOM EXHAUST FANS: 1. EXHAUST FANS SERVING TOILET ROOMS WITH A SINGLE WATER CLOSET SHALL BE ENERGIZED/DE-ENERGIZED VIA THE SAME SWITCH AS THE LIGHTS. MULTI-FIXTURE TOILET ROOM EXHAUST FANS: 1. EXHAUST FANS SERVING TOILET ROOMS WITH MULTIPLE WATER CLOSETS OR URINALS SHALL BE ENERGIZED/DE-ENERGIZED VIA A TIME CLOCK. COORDINATE THE TIME CLOCK HOURS OF OPERATION WITH THE OWNER. DOG WASH EXHAUST FAN: 1. PROVIDE AN OCCUPANCY SENSOR IN THE SPACE TO ENERGIZE THE DOG WASH EXHAUST FAN. THE OCCUPANCY SENSOR SHALL BE INDEPENDENT FROM THE LIGHTS. 2. THE OCCUPANCY SENSOR SHALL ENERGIZE THE EXHAUST FAN WHEN THE SPACE IS OCCUPIED. THE EXHAUST FAN SHALL BE DE-ENERGIZED WHEN THE SPACE HAS BEEN UNOCCUPIED FOR 20 MINUTES (ADJ.). 3. THE INTAKE AND EXHAUST MOTORIZED DAMPERS SHALL BE INTERLOCKED WITH THE EXHAUST FAN. STAIR PRESSURIZATION FANS: 1. SET POINTS: 2. MINIMUM STAIRWELL PRESSURE: 0.1”W.G. 3. MAXIMUM STAIRWELL PRESSURE: 0.35”W.G. 4. DUCT RISER STATIC PRESSURE SET POINT: 0.35”W.G. 5. GENERAL: 6. THE STAIRWELL PRESSURIZATION SYSTEM IS INTENDED TO FUNCTION WITH [ALL DOORS CLOSED] [# DOORS OPEN]. 7. THE STAIRWELL PRESSURIZATION SYSTEM CONTROLER (SPSC) SHALL COMMUNICATE WITH AND BE MONITORED BY THE FIRE ALARM SYSTEM (FAS). 8. THE SPSC SHALL CONTROL THE STAIRWELL PRESSURIZATION SYSTEM. ALL HARDWARE (CABLING/SWITCHING INFRASTRUCTURE) SHALL BE UL 864 LISTED FOR FIRE ALARM SYSTEM USE. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE WIRING AND INSTALL IN CONDUIT THROUGHOUT WITH LONG SWEEP TURNS. COORDINATE CONDUIT, WIRE SIZE, AND QUANTITY WITH EQUIPMENT VENDOR. 9. THE STAIRWELL PRESSURIZATION SYSTEM SHALL OPERATE TO MAINTAIN POSITIVE STAIRWELL PRESSURIZATION RELATIVE TO THE BUILDING AND SMOKE-FREE PASSAGE FOR OCCUPANTS EXITING THE BUILDING DURING A SMOKE AND/OR FIRE EVENT. 10. ALL LOCALLY-CONTROLLED SETPOINTS AND TIME DELAYS SHALL BE ADJUSTABLE VIA THE STAIRWELL PRESSURIZATION SYSTEM CONTROLLER. 11. THE SMOKE DAMPER AT THE SUPPLY FAN SHALL BE OF THE SPRING OPEN/POWER CLOSE TYPE. THE DAMPER SHALL BE CLOSED WHEN THE SYSTEM IS NOT IN OPERATION. 12. SYSTEM OPERATION: 13. THE STAIRWELL PRESSURIZATION SYSTEM SHALL BE ACTIVATED BY THE FIRE ALARM SYSTEM. 14. A SMOKE DETECTOR DOWNSTREAM OF THE SUPPLY FAN ON THE ROOF SHALL PREVENT SMOKE FROM BEING INTRODUCED VIA THE SUPPLY AIR FAN INTAKE. UPON DETECTION OF SMOKE, THE SUPPLY FAN SHALL BE DE-ENERGIZED, THE SMOKE DAMPER SHALL CLOSE, AND AN ALARM SHALL BE INITIATED AT THE SPSC. A MANUAL RESET FOR THE SMOKE DETECTOR SHALL BE PROVIDED. IF THE SMOKE DETECTOR IS RESET OR BYPASSED AT THE FIREFIGHTERS SMOKE CONTROL STATION, THE SYSTEM SHALL RESUME NORMAL OPERATION. 15. PRIOR TO ENTERING NORMAL OPERATION, THE SPSC SHALL VERIFY THAT THE SMOKE DAMPER IS FULLY OPEN VIA AN END SWITCH, THE STAIR PRESSURIZATION FAN IS RUNNING VIA A CURRENT SWITCH, AND THE MINIMUM AND MAXIMUM PRESSURES ARE MAINTAINED. 16. A BI-DIRECTIONAL PRESSURE SENSOR SHALL BE PROVIDED AT EACH INJECTION POINT SUPPLYING AIR INTO THE STAIRWELL. THE PRESSURE SENSOR SHALL MODULATE THE MOTORIZED DAMPER AT THE SUPPLY REGISTER TO MAINTAIN THE MINIMUM AND MAXIMUM PRESSURE SET POINTS INSIDE THE STAIR RELATIVE TO THE BUILDING. 17. A STATIC PRESSURE SENSOR SHALL BE INSTALLED 2/3 OF THE WAY DOWN THE DUCT RISER. THE STATIC PRESSURE SENSOR SHALL MODULATE THE STAIR PRESSURIZATION FAN TO MAINTAIN THE DUCT STATIC PRESSURE. 18. A STATIC PRESSURE SENSOR SHALL BE INSTALLED IN AT THE MID POINT OF THE STAIR. THE STATIC PRESSURE SET POINT FOR THE SENSOR SHALL BE DETERMINED DURING TESTING AND BALANCING. THE STAIR PRESSURIZATION FAN SHALL MODULATE TO MAINTAIN THE STATIC PRESSURE SET POINT. 19. A COUNTER BALANCED BAROMETRIC RELIEF DAMPER SHALL BE INSTALLED AT THE TOP OF THE STAIR TO RELIEVE PRESSURE IN EXCESS OF THE MAXIMUM STAIRWELL PRESSURE. 20. ALARMS: 21. UNDER EMERGENCY OPERATION, ANY SYSTEM MALFUNCTION REGISTERED AT THE LOCAL DDC CONTROLLER LEVEL, SHALL BE TRANSMITTED, THROUGH THE FAS CONTROL INTERFACE, TO THE FAS AS A SUPERVISORY CONDITION. 22. SYSTEM CONDITIONS GENERATED THROUGH LOCAL MAINTENANCE OR TESTING SHALL BE LOGGED AT THE FAS, BUT SHALL NOT BE TRANSMITTED TO THE FAS AS ALARM CONDITIONS. 23. SUPPLY FAN SMOKE DETECTOR. 24. SUPPLY FAN SMOKE DETECTOR FAULT. 25. SYSTEM RETURN TO NON-EMERGENCY STATUS: 26. AN INDICATION, FROM THE FAS, OF AN ALL-CLEAR CONDITION, CONTROL SHALL BE RETURNED TO THE LOCAL PRESSURIZATION SYSTEM CONTROLLERS. 27. ONCE THE FAS IS RESET TO 'NORMAL' STATUS, THE FAN SERVING EACH STAIRWELL SHALL BE STOPPED. 28. UPON PROOF THAT FANS AT THE STAIRWELL ARE STOPPED, AS INDICATED BY CURRENT TRANSDUCERS, THE FANS' RESPECTIVE SMOKE DAMPER SHALL BE CLOSED AND VERIFIED BY A CLOSED-POSITION END SWITCH. 29. POWERED SENSORS AND INSTRUMENTS SHALL BE RETURNED TO THEIR NORMAL POSITIONS AND STATES. GARAGE VENTILATION FANS: 1. SET POINTS: 2. GARAGE TEMPERATURE SET POINT: 90°F (ADJ.). 3. CARBON MONOXIDE HIGH LIMIT SET POINT: 25 PPM. 4. CARBON MONOXIDE ALARM LIMIT SET POINT: 100 PPM. 5. NITROGEN DIOXIDE HIGH LIMIT SET POINT: 0.7 PPM. 6. NITROGEN DIOXIDE ALARM LIMIT SET POINT: 5 PPM. 7. SYSTEM DESCRIPTION: 8. PROVIDE ONE (1) STANDALONE GAS DETECTION AND CONTROL SYSTEM FOR EACH LEVEL OF THE PARKING GARAGE (AS A VALUE ENGINEERING ALTERNATIVE, ONE CONTROLLER WITH RELAY MODULE TO PROVIDE SEPARATE CONTROL OF FANS ON A PER LEVEL BASIS MAY BE PROPOSED). 9. ALL CONTROLLERS AND DEVICES SHALL HAVE A WATER/DUST TIGHT CORROSION RESISTANT ENCLOSURE AND AUTOMATIC RESETTING THERMAL CIRCUIT FUSE. QUANTITY AND LOCATION OF SENSORS SHOWN ON THE PLANS ARE APPROXIMATE ONLY AND SHALL BE CONFIRMED BY THE MANUFACTURER PRIOR TO BID. THE SYSTEM MANUFACTURER SHALL FURNISH COMPLETE LAYOUT DRAWINGS DURING THE SUBMITTAL PHASE. 10. SENSORS SHALL BE MOUNTED AT 48" ABOVE FINISHED FLOOR UNLESS DICTATED OTHERWISE BY LOCAL CODE OR THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. 11. SENSOR LOCATIONS SHOWN ON DRAWINGS REPRESENT A GENERAL GUIDELINE. ACTUAL SENSOR SPACING SHALL BE DETERMINED BY THE GAS DETECTION SYSTEM INSTALLER. SENSOR SPACING SHALL BE IN ACCORDANCE WITH THE SUBMITTED MANUFACTURER’S COVERAGE REQUIREMENTS. 12. ALL WIRING SHALL BE PROTECTED BY CONDUIT. 13. THE GARAGE CIRCULATION FANS AND INTERMITTENT EXHAUST FANS SHALL BE PROVIDED WITH MOTOR STARTERS SIZED FOR THE EACH FAN’S MOTOR HORSEPOWER. ALL MOTOR STARTERS AND DISCONNECT SWITCHES INSTALLED IN THE GARAGE SHALL BE NEMA 3R RATED. 14. SYSTEM SHALL BE MANUFACTURED BY HONEYWELL ANALYTICS, OR EQUAL PRODUCTS BY CRITICAL ENVIRONMENT TECHNOLOGIES, MACURCO OR INTEC CONTROLS. 15. SEQUENCE OF OPERATION: 16. THE SYSTEM CONSISTS OF MULTIPLE FANS; A CONTINUOUSLY OPERATING FAN TO PROVIDE THE CODE REQUIRED CONTINUOUS EXHAUST RATE, GARAGE CIRCULATION FANS, AND LARGER FAN(S) CONTROLLED BY THE DETECTION AND MONITORING SYSTEM AS DESCRIBED BELOW. 17. UPON DETECTION OF ELEVATED LEVELS OF CARBON MONOXIDE OR NITROGEN DIOXIDE, THE ASSOCIATED LARGE EXHAUST FANS AND GARAGE CIRCULATION FANS FOR THAT ZONE SHALL BE ENERGIZED, OPENING THE MOTORIZED DAMPER (WHERE APPLICABLE) PRIOR TO THE FAN ENERGIZING. THE FANS SHALL BE DE-ENERGIZED AFTER THE CONTAMINANT CONCENTRATION LEVELS ARE UNDER THE ALLOWABLE LIMITS FOR A PERIOD OF TIME (ADJUSTABLE), AND THE MOTORIZED DAMPERS (WHERE APPLICABLE) SHALL CLOSE. THIS SEQUENCE SHALL REPEAT AFTER EACH DETECTION OF ELEVATED CONTAMINANT LEVELS. 18. SHOULD THE CONTAMINANT LEVELS RISE ABOVE THE ALARM LIMIT SET POINTS, THE SYSTEM SHALL EMIT AN AUDIBLE AND VISUAL ALARM LOCATED IN A CONSPICUOUS LOCATION THE COMBINATION SPEAKER/STROBES LOCATED IN THE GARAGE SHALL BE ACTIVATED. AUDIBLE ALARMS SHALL EMIT A TEMPORAL-4 SIGNAL. 19. A LINE VOLTAGE THERMOSTAT SHALL BE PROVIDED FOR EACH ZONE. IF THE TEMPERATURE SENSED BY THE THERMOSTAT EXCEEDS THE GARAGE TEMPERATURE SET POINT, THE GCF’S ON THE ASSOCIATED ZONE SHALL BE ENERGIZED. 20. SYSTEM COMPONENT MODEL NUMBERS: 21. CONTROLLER (TYPICAL): HONEYWELL ANALYTICS 301C 22. CO SENSOR (TYPICAL): HONEYWELL ANALYTICS E3SCO OR E3SRMSCO 23. NO2 SENSOR (TYPICAL): HONEYWELL ANALYTICS E3SNO2 OR E3SRMNO2 LOADING DOCK EXHAUST WITH VFD CONTROL: 1. SET POINTS: 2. GARAGE TEMPERATURE SET POINT: 90°F (ADJ.). 3. CARBON MONOXIDE HIGH LIMIT SET POINT: 25 PPM. 4. CARBON MONOXIDE ALARM LIMIT SET POINT: 100 PPM. 5. NITROGEN DIOXIDE HIGH LIMIT SET POINT: 0.7 PPM. 6. NITROGEN DIOXIDE ALARM LIMIT SET POINT: 5 PPM. 7. SYSTEM DESCRIPTION: 8. PROVIDE ONE (1) STANDALONE GAS DETECTION AND CONTROL SYSTEM FOR EACH LEVEL OF THE PARKING GARAGE (AS A VALUE ENGINEERING ALTERNATIVE, ONE CONTROLLER WITH RELAY MODULE TO PROVIDE SEPARATE CONTROL OF FANS ON A PER LEVEL BASIS MAY BE PROPOSED). 9. ALL CONTROLLERS AND DEVICES SHALL HAVE A WATER/DUST TIGHT CORROSION RESISTANT ENCLOSURE AND AUTOMATIC RESETTING THERMAL CIRCUIT FUSE. QUANTITY AND LOCATION OF SENSORS SHOWN ON THE PLANS ARE APPROXIMATE ONLY AND SHALL BE CONFIRMED BY THE MANUFACTURER PRIOR TO BID. THE SYSTEM MANUFACTURER SHALL FURNISH COMPLETE LAYOUT DRAWINGS DURING THE SUBMITTAL PHASE. 10. SENSORS SHALL BE MOUNTED AT 48" ABOVE FINISHED FLOOR UNLESS DICTATED OTHERWISE BY LOCAL CODE OR THE MANUFACTURER’S INSTALLATION INSTRUCTIONS. 11. SENSOR LOCATIONS SHOWN ON DRAWINGS REPRESENT A GENERAL GUIDELINE. ACTUAL SENSOR SPACING SHALL BE DETERMINED BY THE GAS DETECTION SYSTEM INSTALLER. SENSOR SPACING SHALL BE IN ACCORDANCE WITH THE SUBMITTED MANUFACTURER’S COVERAGE REQUIREMENTS. 12. ALL WIRING SHALL BE PROTECTED BY CONDUIT. 13. THE GARAGE CIRCULATION FANS AND INTERMITTENT EXHAUST FANS SHALL BE PROVIDED WITH MOTOR STARTERS SIZED FOR THE EACH FAN’S MOTOR HORSEPOWER. ALL MOTOR STARTERS AND DISCONNECT SWITCHES INSTALLED IN THE GARAGE SHALL BE NEMA 3R RATED. 14. SYSTEM SHALL BE MANUFACTURED BY HONEYWELL ANALYTICS, OR EQUAL PRODUCTS BY CRITICAL ENVIRONMENT TECHNOLOGIES, MACURCO OR INTEC CONTROLS. 15. SEQUENCE OF OPERATION: 16. THE SYSTEM CONSISTS OF CONTINUOUSLY OPERATING FAN(S) CONTROLLED BY A VARIABLE SPEED DRIVE TO PROVIDE THE CODE REQUIRED EXHAUST RATES. THE DETECTION AND MONITORING SYSTEM AS DESCRIBED BELOW SHALL VARY THE FAN SPEED PROPORTIONALLY IN RESPONSE TO ELEVATED CONTAMINANT LEVELS. THE FAN(S) SHALL OPERATE AT 100% CAPACITY WHEN THE CO OR NO2 LEVEL EXCEEDS THE HIGH LIMIT SET POINTS. 17. UPON DETECTION OF ELEVATED LEVELS OF CARBON MONOXIDE OR NITROGEN DIOXIDE, FOR EACH ZONE, THE ASSOCIATED FAN(S) SHALL INCREASE IN SPEED AND THE GARAGE CIRCULATION FANS SHALL BE ENERGIZED. THE FAN(S) SHALL DECREASE IN SPEED AND THE GARAGE CIRCULATION FANS SHALL BE DE-ENERGIZED AFTER THE CONTAMINANT LEVELS ARE BELOW THE HIGH LIMIT SET POINT FOR A PERIOD OF TIME (ADJUSTABLE). THIS SEQUENCE SHALL REPEAT AFTER EACH DETECTION OF ELEVATED CONTAMINANT LEVELS. 18. SHOULD THE CONTAMINANT LEVELS RISE ABOVE THE ALARM LIMIT SET POINTS, THE SYSTEM SHALL EMIT AN AUDIBLE AND VISUAL ALARM LOCATED IN A CONSPICUOUS LOCATION THE COMBINATION SPEAKER/STROBES LOCATED IN THE GARAGE SHALL BE ACTIVATED. AUDIBLE ALARMS SHALL EMIT A TEMPORAL-4 SIGNAL. 19. A LINE VOLTAGE THERMOSTAT SHALL BE PROVIDED FOR EACH ZONE. IF THE TEMPERATURE SENSED BY THE THERMOSTAT EXCEEDS THE GARAGE TEMPERATURE SET POINT, THE GCF’S ON THE ASSOCIATED ZONE SHALL BE ENERGIZED. 20. SYSTEM COMPONENT MODEL NUMBERS: 21. CONTROLLER (TYPICAL): HONEYWELL ANALYTICS 301C 22. CO SENSOR (TYPICAL): HONEYWELL ANALYTICS E3SCO OR E3SRMSCO 23. NO2 SENSOR (TYPICAL): HONEYWELL ANALYTICS E3SNO2 OR E3SRMNO2 DUCTLESS SPLIT SYSTEM HEAT PUMP UNITS: 1. DUCTLESS SPLIT SYSTEM HEAT PUMP UNITS SHALL BE CONTROLLED BY A REMOTE LOW VOLTAGE HEATING/COOLING WALL MOUNTED THERMOSTAT. THE THERMOSTAT SHALL OPEN/CLOSE THE REVERSING VALVE AND CYCLE THE SUPPLY FAN, MODULATE THE COMPRESSOR, AND MODULATE THE CONDENSER FAN TO MAINTAIN A COOLING SET POINT OF 75°F (ADJ.) AND A HEATING SET POINT OF 70°F (ADJ.). DUCTLESS SPLIT SYSTEM A/C UNITS (COOLING ONLY): 1. DUCTLESS SPLIT SYSTEM A/C UNITS SHALL BE CONTROLLED BY A REMOTE LOW VOLTAGE COOLING ONLY WALL MOUNTED THERMOSTAT. THE THERMOSTAT SHALL CYCLE THE SUPPLY FAN, MODULATE THE COMPRESSOR, AND MODULATE THE CONDENSER FAN TO MAINTAIN A COOLING SET POINT OF 75°F (ADJ.). DWELLING UNIT SPLIT SYSTEM HEAT PUMP UNITS: 1. THERMOSTAT: 7-DAY PROGRAMMABLE THERMOSTAT WITH AUTO-CHANGEOVER CONTROL. PROVIDE WITH ADAPTIVE SETBACK RECOVERY CONTROLS TO ANTICIPATE THE TIME REQUIRED TO BRING THE SPACE TO SETPOINT WHEN RETURNING TO NORMAL MODE FROM SETBACK MODE. PROVIDE WITH REMOTE OUTDOOR AIR TEMPERATURE SENSOR. BASIS OF DESIGN: BRAEBURN 5220 OR APPROVED EQUAL. 2. COOLING MODE: THE FAN SHALL CYCLE, AND THE COMPRESSOR SHALL STAGE TO MAINTAIN THE SPACE SET POINT. THE REVERSING VALVE SHALL BE IN THE COOLING POSITION. 3. HEATING MODE: THE FAN SHALL CYCLE, AND THE COMPRESSOR SHALL STAGE TO MAINTAIN THE SPACE SET POINT. THE REVERSING VALVE SHALL BE IN THE HEATING POSITION. IF THE HEATING LOAD CANNOT BE MET BY THE COMPRESSOR ALONE, THE AUXILIARY ELECTRIC HEATER SHALL BE ENERGIZED IN STAGES TO AUGMENT THE COMPRESSOR OPERATION. 4. SMOKE DETECTOR INTERLOCK: THE UNIT SHALL BE DE-ENERGIZED UPON DETECTION OF SMOKE BY THE SPACE SMOKE DETECTOR TO ALLOW THE RADIATION DAMPER TO CLOSE. REFER TO AIR HANDLER/FURNACE SHUTDOWN WIRING DETAIL FOR ADDITIONAL INFORMATION. AMENITY SPLIT-SYSTEM HEAT PUMP UNITS (WITHOUT CO2 CONTROL): 1. THERMOSTAT: 7-DAY PROGRAMMABLE THERMOSTAT WITH AUTO-CHANGEOVER CONTROL. PROVIDE WITH ADAPTIVE SETBACK RECOVERY CONTROLS TO ANTICIPATE THE TIME REQUIRED TO BRING THE SPACE TO SETPOINT WHEN RETURNING TO NORMAL MODE FROM SETBACK MODE. PROVIDE WITH REMOTE OUTDOOR AIR TEMPERATURE SENSOR. BASIS OF DESIGN: BRAEBURN 5220 OR APPROVED EQUAL. 2. COOLING MODE: THE FAN SHALL RUN CONTINUOSLY DURING OCCUPIED HOURS, AND THE COMPRESSOR SHALL CYCLE TO MAINTAIN THE SPACE SET POINT. THE REVERSING VALVE SHALL BE IN THE COOLING POSITION. 3. HEATING MODE: THE FAN SHALL RUN CONTINUOSLY DURING OCCUPIED HOURS, AND THE COMPRESSOR SHALL CYCLE TO MAINTAIN THE SPACE SET POINT. THE REVERSING VALVE SHALL BE IN THE HEATING POSITION. IF THE HEATING LOAD CANNOT BE MET BY THE COMPRESSOR ALONE, THE AUXILIARY ELECTRIC HEATER SHALL BE ENERGIZED IN STAGES TO AUGMENT THE COMPRESSOR OPERATION. 4. SMOKE DETECTOR INTERLOCK (WHERE SMOKE DETECTORS ARE SHOWN): THE UNIT SHALL BE DE-ENERGIZED UPON DETECTION OF SMOKE BY THE SMOKE DETECTOR AT THE UNIT INLET. 5. WHERE AN ASSOCIATED OUTDOOR AIR FAN SUPPLIES OUTDOOR AIR TO THE INDOOR UNIT, THE OUTDOOR AIR FAN SHALL RUN CONTINUOUSLY. A MOTORIZED DAMPER SHALL BE INTERLOCKED WITH THE OUTDOOR AIR FAN. ROOF MOUNTED UNITS: 1. SET POINTS: 2. SUPPLY AIR TEMPERATURE SET POINT: 70°F (ADJ.). 3. SUPPLY AIR MAXIMUM DEW POINT TEMPERATURE: 55°F (ADJ.). 4. CORRIDOR COOLING SET POINT: 75°F (ADJ.). 5. CORRIDOR HEATING SET POINT: 70°F (ADJ.). 6. GENERAL: 7. THE UNIT SHALL BE PROVIDED WITH A REMOTE TOUCHSCREEN CONTROL PANEL TO PROVIDE A REMOTE INTERFACE WITH THE ONBOARD CONTROLLER.THE REMOTE CONTROL PANEL SHALL BE LOCATED IN THE BUILDING ENGINEER’S OFFICE OR AS INDICATED ON THE DRAWINGS. 8. THE REMOTE CONTROL PANEL SHALL MONITOR THE FOLLOWING POINTS FOR TROUBLESHOOTING: 1. OUTDOOR AIR DRY BULB TEMPERATURE. 2. OUTDOOR AIR DEW POINT TEMPERATURE. 3. COOLING COIL LEAVING AIR DRY BULB TEMPERATURE. 4. COOLING COIL LEAVING AIR DEW POINT TEMPERATURE. 5. SUPPLY AIR DRY BULB TEMPERATURE. 6. SUPPLY AIR DEW POINT TEMPERATURE. 7. OUTDOOR AIR FLOW RATE. 9. NORMAL MODE: 10. THE UNIT SHALL OPERATE IN NORMAL MODE UNLESS MANUALLY COMMANDED OFF FOR MAINTENANCE. 11. WHILE OPERATING IN NORMAL MODE, THE SUPPLY FAN SHALL BE ENERGIZED, THE OUTDOOR AIR DAMPER SHALL BE OPEN, THE COMPRESSOR(S) SHALL MODULATE/STAGE, THE CONDENSER FANS SHALL STAGE, THE HOT GAS REHEAT COIL SHALL MODULATE, AND THE NATURAL GAS FURNACE SHALL STAGE TO MAINTAIN THE SUPPLY AIR TEMPERATURE SET POINT AND SUPPLY AIR MAXIMUM DEW POINT TEMPERATURE. 12. DEHUMIDIFICATION USING THE COOLING COIL AND HOT GAS REHEAT COIL SHALL BE ENABLED WHENEVER THE OUTDOOR AIR DEW POINT TEMPERATURE IS GREATER THAN 50°F (ADJ.). 13. SUPPLY AIR TEMPERATURE RESET: 1. AVERAGING SPACE TEMPERATURE SENSORS SHALL BE INSTALLED IN THE CORRIDOR ON LEVELS 2, 5, 8, AND 12. 2. IF THE AVERAGE CORRIDOR TEMPERATURE RISES ABOVE THE CORRIDOR COOLING SET POINT, THE SUPPLY AIR TEMPERATURE SHALL BE RESET TO 65°F (ADJ.) UNTIL THE SET POINT IS REACHED. 3. IF THE AVERAGE CORRIDOR TEMPERATURE FALLS BELOW THE CORRIDOR HEATING SET POINT, THE SUPPLY AIR TEMPERATURE SHALL BE RESET TO 80°F (ADJ.) UNTIL THE SET POINT IS REACHED. 14. SMOKE DETECTOR INTERLOCK: 15. THE RETURN AIR SMOKE DETECTOR SHALL BE INTERLOCKED TO SHUT DOWN THE SUPPLY FAN UPON DETECTION OF PRODUCTS OF COMBUSTION. 16. ALARMS: 17. DIRTY FILTER ALARM: FILTER PRESSURE DROP EXCEEDS 1.0”W.G. (ADJ.). 18. SYSTEM STATUS MIS-MATCH: UNIT IS COMMANDED ON, BUT STATUS IS OFF OR VICE VERSA. 19. HIGH SUPPLY AIR TEMPERATURE ALARM: SUPPLY AIR TEMPERATURE EXCEEDS 110°F (ADJ.). 20. LOW SUPPLY AIR TEMPERATURE ALARM: SUPPLY AIR TEMPERATURE IS LESS THAN 50°F (ADJ.). 21. HIGH SUPPLY AIR DEW POINT TEMPERATURE: SUPPLY AIR DEW POINT TEMPERATURE EXCEEDS 60°F (ADJ.). K L M N P Q R U 7 6 5 S 8 T RETAIL 791 CIRCULATION 772 ELEVATOR 3 339 TRASH 385 RESTAURANT 325 STAIR 5 1175 TR 1 EUH R-12 EUH R-13 EUH R-14 EUH R-15 EUH R-16 EUH R-17 EUH 1-2 EWH 1-3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:44:41 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.01A ALS SDW 2247601 LEVEL 1 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 1 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV C D E F G H J 7 6 5 8 B OV XY STAIR 2 824 BOH 531 MAIL ROOM 825 ELEVATOR 2 1341 ELEVATOR 1 1342 LEASING/LOBBY 779 FITNESS 803 RETAIL 791 EUH R-11 EUH R-12 EWH 1-2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:44:47 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.01B ALS SDW 2247601 LEVEL 1 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 1 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV C D 9 10 11 13 14 16 17 8 B 15 12 STAIR 1 1203 RETAIL 974 TRASH 967 RETAIL 330 RETAIL 812 RETAIL 973 STAIR 2 824 TR 2 EUH R-2 EUH R-3 EUH R-4 EUH R-1 EUH R-5 EUH R-6 EUH R-7 EUH R-8 EUH R-9 EUH R-10 EUH 1-1 M EWH 1-1 EWH 1-2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:44:53 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.01C ALS SDW 2247601 LEVEL 1 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 1 -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T ELEVATOR 3 340 CIRCULATION 1317 BOH 701 STAIR 5 1176 GSF 2-1 GSF 2-2 SP 5 TR 1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:44:59 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.02A ALS SDW 2247601 LEVEL 2 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV C D E F G H J 4 7 6 5 1 2 8 3 B OV XY STAIR 2 800 CIRCULATION 643 ELEVATOR 1 1344 ELEVATOR 2 1343 BOH 632 STAIR 3 1184 GEF 2-1 GEF 2-2 SP 2 EWH 2-1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:45:01 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.02B ALS SDW 2247601 LEVEL 2 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV C D 9 10 11 13 14 16 17 8 B 15 12 STAIR 2 800 TR 2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:45:04 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.02C ALS SDW 2247601 LEVEL 2 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T ELEC ROOM 688 STAIR 5 1177 PET SPA 1433 RESIDENTIAL STORAGE 400 BOH 1424TELECOM 904 CIRCULATION 927 UNIT S2 845 UNIT A4 1421 UNIT AD2 871 UNIT AD2 844 UNIT A2 841 UNIT A5 872 BOH 842 UNIT S3 813UNIT A6 499 ELEVATOR 3 341 TRASH 371 GSF 3-1 GSF 3-2 SP 5 TR 1 RTU 7 RTU 8 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:45:11 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.03A ALS SDW 2247601 LEVEL 3 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV TT C D E F G H J 4 7 6 5 1 2 8 3 B OV XY STAIR 3 1189 UNIT B3 850 RESIDENTIAL STORAGE 399 UNIT B3 740 UNIT A6 497 UNIT A6 510 RESIDENTIAL STORAGE 691 TELECOM 832 ELEVATOR 2 1345 ELEVATOR 1 1346 ELEC ROOM 851 STAIR 2 804 FIRE COMMAND 1239 ELEC ROOM 692 TELECOM 899 GEF 3-1 GEF 3-2 SP 2 SP 3 RTU 1 DFH 1-2 DHP 1-2 DHP 1-1 DFH 1-1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:45:15 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.03B ALS SDW 2247601 LEVEL 3 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV C D 9 10 11 13 14 16 17 8 B 15 12 ELEC ROOM 851 STAIR 2 804 UNIT A6 838 UNIT BA1 863 UNIT A2 854 UNIT BA1 933 CIRCULATION 434 UNIT B2 858 UNIT B2 859 UNIT AU1 866 UNIT AU1 506 UNIT B2 956 UNIT A2 934 UNIT BA1 936 UNIT B10 485 STAIR 1 1205 UNIT B2 680 UNIT B2 862 UNIT AD2 957 BOH 828 TRASH 960 TELECOM 935 C 10x8 RA 10x8 SA CC 10x8 RA RTU 9 RTU 10 10x8 SA C8x8 SA 8x8 SA 8x8 SA TR 2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:45:20 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.03C ALS SDW 2247601 LEVEL 3 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T STAIR 5 1178 BOH 1441 BOH 1441 BOH 1441BOH 1441 CIRCULATION 1320 UNIT S2 631 UNIT A4 929 UNIT AD2 834 UNIT AD2 630 UNIT A2 616 UNIT A5 839 BOH 623 UNIT S3 361UNIT A6 458 ELEVATOR 3 343 TRASH 372 GSF 4-1 GSF 4-2 SP 5 TR 1 RTU 7 RTU 8 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:35:16 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.04A ALS SDW 2247601 LEVEL 4 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV C D E F G H J 4 7 6 5 1 2 8 3 B OV XY UNIT B3 741 BOH 1434 UNIT B3 739 UNIT A6 511 UNIT A6 433 RESIDENTIAL STORAGE 874 RESIDENTIAL STORAGE 874 ELEVATOR 2 1347 ELEVATOR 1 1348 ELEC ROOM 750 STAIR 2 805 BOH 1430 LOADING 321 GEF 4-1 GEF 4-2 SP 2 SP 3 RTU 1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:35:19 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.04B ALS SDW 2247601 LEVEL 4 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV C D 9 10 11 13 14 16 17 8 B 15 12 ELEC ROOM 750 STAIR 2 805 UNIT A6 836 UNIT BA1 939 UNIT A2 937 UNIT BA1 940 CIRCULATION 438 UNIT B2 642 UNIT B2 647 UNIT AU1 735 UNIT AU1 504 UNIT B2 736 UNIT A2 941 UNIT BA1 943 UNIT B10 481 STAIR 1 1206 UNIT B2.1 428 UNIT B2 683 UNIT AD2 968 BOH 926 TRASH 961 BOH 942 C 10x8 RA 10x8 SA CC 10x8 RA RTU 9 RTU 10 10x8 SA C8x8 SA 8x8 SA 8x8 SA TR 2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:35:24 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.04C ALS SDW 2247601 LEVEL 4 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T STAIR 5 1179 RESIDENTIAL STORAGE 394 RESIDENTIAL STORAGE 394 TELECOM 898 CIRCULATION 774 UNIT S2 865 UNIT A4 391 UNIT AD2 502 UNIT AD2 498 UNIT A2 689 UNIT A5 414 BOH 690 UNIT S3-A 488UNIT A6 405 ELEVATOR 3 344 TRASH 373 STAIR 4 378 GSF 5-1 GSF 5-2 SP 5 TR 1 RTU 7 RTU 8 EWH 5-1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:35:32 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.05A ALS SDW 2247601 LEVEL 5 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV C D E F G H J 4 7 6 5 1 2 8 3 B OV XY UNIT B3 764 MAINTENENCE AND ENGINEERING 827 UNIT B3 763 UNIT A6 401 UNIT A6 403 RESIDENTIAL STORAGE 379 TELECOM 846 ELEVATOR 2 1349 ELEVATOR 1 1350 ELEC ROOM 878 STAIR 2 806 BOH 568 STAIR 3 1191 GEF 5-1 GEF 5-2 SP 2 SP 3 RTU 1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:35:36 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.05B ALS SDW 2247601 LEVEL 5 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV C D 9 10 11 13 14 16 17 8 B 15 12 ELEC ROOM 878 STAIR 2 806 UNIT A6 833 UNIT BA1-A 487 UNIT A2 944 UNIT BA1 948 CIRCULATION 432 UNIT B2 706 UNIT B2 708 UNIT AU1 518 UNIT AU1 514 UNIT B2 721 UNIT A2 949 UNIT BA1-A 486 UNIT B10 807 STAIR 1 1207 UNIT B2.1 427 UNIT B2 720 UNIT AD2 969 BOH 928 TRASH 962 TELECOM 950 C 10x8 RA 10x8 SA CC 10x8 RA RTU 9 RTU 10 10x8 SA C8x8 SA 8x8 SA 8x8 SA TR 2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:35:41 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.05C ALS SDW 2247601 LEVEL 5 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV UNIT A6 411 UNIT AD2 470 STAIR 4 362 BOH 392 UNIT B1 460 UNIT A1 436 UNIT A7 751 UNIT A1 435 UNIT B1 452 UNIT A1 353 UNIT A1 440 UNIT B1 448 UNIT BA1.1 482 UNIT BA1.1 979 UNIT B1 450 UNIT A1 437 UNIT A1 352 UNIT A2-A 634 UNIT AD2 513 UNIT AD2 742 UNIT A4 1425 UNIT S2 522 STAIR 5 1074 UNIT S4 402 UNIT A5 419 UNIT A7 523 UNIT B2 521 UNIT B2.1 566 AMENITY 727 ELEVATOR 3 338 TRASH 367 UNIT B5 820 UNIT B1 464 RTU 4 RTU 5 RTU 6 RTU 7 RTU 8 C 10x10 RA10x10 SA8x8 SA C 10x10 SA C 10x10 SA C C 10x10 SA C 10x10 RA C 10x10 RA C 10x10 RA 8x8 SA 10x8 SA 8x8 SA 10x8 SA 10x8 SA 8x8 SA C 10x10 RA 10x10 SA C 10x8 SA 8x8 SA 10x8 SA SP 4 SP 5 TR 1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:35:48 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.06A ALS SDW 2247601 LEVEL 6 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV STAIR 3 947 UNIT B6 335 UNIT A1 446 UNIT B1 478 UNIT AD2 461 UNIT A5 483 UNIT A6 406 UNIT A6 411 UNIT A1 442 UNIT A7 447 UNIT A1 444 UNIT B1 474 UNIT A1 445 UNIT S2 730 UNIT B1 476 UNIT A1 484 UNIT A1 354 UNIT A1 333 UNIT B6 500 UNIT BA1 978 STAIR 2 793 ELEC ROOM 528 ELEVATOR 1 1340 ELEVATOR 2 1339 BOH 792 RTU 1 RTU 2 RTU 3 CC C C C C 10x8 SA 10x8 RA 10x10 SA 10x10 RA 8x8 SA 8x8 SA 10x10 SA 8x8 SA 10x8 SA 10x10 RA SP 2 SP 3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:35:55 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.06B ALS SDW 2247601 LEVEL 6 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV STAIR 2 793 ELEC ROOM 528 UNIT B2 501 CIRCULATION 431 UNIT A6 387 UNIT BA1 954 UNIT B2 515 UNIT B2 517 UNIT AU1 336 UNIT AU1 503 BOH 890 BOH 843 BOH 829 UNIT A2 952 UNIT BA1 955 UNIT A2-A 489 TRASH 958 BOH 930 UNIT BA1 977 UNIT B10 821 UNIT B2.1 891 UNIT B2 762 UNIT AD2 970 STAIR 1 975 UNIT B2 760 C 10x8 RA 10x8 SA CC 10x8 RA RTU 9 RTU 10 10x8 SA C8x8 SA 8x8 SA 8x8 SA TR 2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:36:00 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.06C ALS SDW 2247601 LEVEL 6 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV UNIT A6 415 UNIT AD2 1211 STAIR 4 381 BOH 1227 UNIT B1 554 UNIT A1 538 UNIT A7 612 UNIT A1 537 UNIT B1 552 UNIT A3 1372 UNIT A1 541 UNIT B1 548 UNIT BA1.1 761 UNIT BA1.1 767 UNIT B1 550 UNIT A1 539 UNIT A3 1371 UNIT A2 579 UNIT AD2 599 UNIT AD2 1375 UNIT A4 1426 UNIT S2 609 STAIR 5 1180 UNIT S4 410 UNIT A5 604 UNIT A7 610 UNIT B2 608 UNIT B2.1 575 ELEVATOR 3 346 TRASH 376 UNIT B5 818 UNIT B1 556 RTU 4 RTU 5 RTU 6 RTU 7 RTU 8 C 10x10 RA10x10 SA8x8 SA C 10x10 SA C 10x10 SA C C 10x10 SA C 10x10 RA C 10x10 RA C 10x10 RA 8x8 SA 10x8 SA 8x8 SA 10x8 SA 10x8 SA 8x8 SA C 10x10 RA 10x10 SA C 10x8 SA 8x8 SA 10x8 SA SP 4 SP 5 TR 1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:36:07 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.07A ALS SDW 2247601 LEVEL 7 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV STAIR 3 1192 UNIT B6 1376 UNIT A1 546 UNIT B1 562 UNIT AD2 1210 UNIT A5 1200 UNIT A6 413 UNIT A6 415 UNIT A1 543 UNIT A7 547 UNIT A1 544 UNIT B1 558 UNIT A1 545 UNIT A2 613 UNIT B1 560 UNIT A1 570 UNIT A3 1373 UNIT A1 572 UNIT B6 586 UNIT BA1 527 STAIR 2 808 ELEC ROOM 607 ELEVATOR 1 1352 ELEVATOR 2 1351 BOH 830 RTU 1 RTU 2 RTU 3 CC C C C C 10x8 SA 10x8 RA 10x10 SA 10x10 RA 8x8 SA 8x8 SA 10x10 SA 8x8 SA 10x8 SA 10x10 RA SP 2 SP 3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:36:13 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.07B ALS SDW 2247601 LEVEL 7 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV STAIR 2 808 ELEC ROOM 607 UNIT B2 535 CIRCULATION 430 UNIT A6 532 UNIT BA1 982 UNIT B2 1386 UNIT B2 1387 UNIT AU1 1392 UNIT AU1 505 BOH 920 BOH 918 BOH 913 UNIT A2 980 UNIT BA1 983 UNIT A2 984 TRASH 963 BOH 931 UNIT BA1 986 UNIT B10 473 UNIT B2.1 583 UNIT B2 1391 UNIT AD2 971 STAIR 1 1208 UNIT B2 1389 C 10x8 RA 10x8 SA CC 10x8 RA RTU 9 RTU 10 10x8 SA C8x8 SA 8x8 SA 8x8 SA TR 2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:36:19 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.07C ALS SDW 2247601 LEVEL 7 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV UNIT A6 421 UNIT AD2 1226 STAIR 4 383 BOH 1232 UNIT B1 661 UNIT A1 645 UNIT A7 717 UNIT A1 644 UNIT B1 659 UNIT A3 356 UNIT A1 648 UNIT B1 655 UNIT BA1.1 790 UNIT BA1.1 860 UNIT B1 657 UNIT A1 646 UNIT A3 355 UNIT A2 684 UNIT AD2 707 UNIT AD2 1326 UNIT A4 1427 UNIT S2 714 STAIR 5 1181 UNIT S4 409 UNIT A5 709 UNIT A7 715 UNIT B2 713 UNIT B2.1 596 UNIT S3-A 492 ELEVATOR 3 350 TRASH 377 UNIT B5 678 UNIT B1 663 RTU 4 RTU 5 RTU 6 RTU 7 RTU 8 C 10x10 RA10x10 SA8x8 SA C 10x10 SA C 10x10 SA C C 10x10 SA C 10x10 RA C 10x10 RA C 10x10 RA 8x8 SA 10x8 SA 8x8 SA 10x8 SA 10x8 SA 8x8 SA C 10x10 RA 10x10 SA C 8x8 SA 10x8 SA SP 4 SP 5 TR 1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:36:30 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.08A ALS SDW 2247601 LEVEL 8 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV STAIR 3 1193 UNIT B6 1325 UNIT A1 653 UNIT B1 669 UNIT AD2 1225 UNIT A5 1222 UNIT A6 420 UNIT A6 421 UNIT A1 650 UNIT A7 654 UNIT A1 651 UNIT B1 665 UNIT A1 652 UNIT A2-A 637 UNIT B1 667 UNIT A1 675 UNIT A3 357 UNIT A1 677 UNIT B6 699 UNIT BA1-A 490 STAIR 2 809 ELEC ROOM 1328 ELEVATOR 1 1354 ELEVATOR 2 1353 BOH 879 RTU 1 RTU 2 RTU 3 CC C C C C 10x8 SA 10x8 RA 10x10 SA 10x10 RA 8x8 SA 8x8 SA 10x10 SA 8x8 SA 10x8 SA 10x10 RA SP 2 SP 3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:36:37 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.08B ALS SDW 2247601 LEVEL 8 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV STAIR 2 809 ELEC ROOM 1328 UNIT B2 542 CIRCULATION 429 UNIT A6 534 UNIT BA1 989 UNIT B2 1338 UNIT B2 1359 UNIT AU1 1378 UNIT AU1 508 BOH 924 BOH 923 BOH 921 UNIT A2 987 UNIT BA1 990 UNIT A2-A 491 TRASH 964 BOH 932 UNIT BA1 993 UNIT B10 472 UNIT B2.1 598 UNIT B2 1377 UNIT AD2 972 STAIR 1 1209 UNIT B2 1365 C 10x8 RA 10x8 SA CC 10x8 RA RTU 9 RTU 10 10x8 SA C8x8 SA 8x8 SA 8x8 SA TR 2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:36:46 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.08C ALS SDW 2247601 LEVEL 8 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV UNIT A6 424 UNIT AD2 1221 STAIR 4 386 BOH 1235 UNIT B1 591 UNIT A1 565 UNIT A7 743 UNIT A1 564 UNIT B1 589 UNIT A3 747 UNIT A1 573 UNIT B1 584 UNIT BA1.1 861 UNIT BA1.1 867 UNIT B1 587 UNIT A1 571 UNIT A3 746 UNIT A2 682 UNIT AD2 722 UNIT AD2 757 UNIT A4 1428 UNIT S2 848 STAIR 5 1182 UNIT S4 766 UNIT A5 723 UNIT A7 734 UNIT B2 726 UNIT B2.1 624 UNIT S3 816 ELEVATOR 3 351 TRASH 380 UNIT B5 359 UNIT B1 595 RTU 4 RTU 5 RTU 6 RTU 7 RTU 8 C 10x10 RA10x10 SA8x8 SA C 10x10 SA C 10x10 SA C C 10x10 SA C 10x10 RA C 10x10 RA C 10x10 RA 8x8 SA 10x8 SA 8x8 SA 10x8 SA 10x8 SA 8x8 SA C 10x10 RA 10x10 SA C 10x8 SA 8x8 SA 10x8 SA SP 4 SP 5 SP 4 SP 5 TR 1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:41:48 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.09A ALS SDW 2247601 LEVEL 9-10 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 9-10 -FLOOR PLAN -AREA A1 DATE DESCRIPTION REV STAIR 3 1194 UNIT B6 756 UNIT A1 581 UNIT B1 615 UNIT AD2 1220 UNIT A5 1217 UNIT A6 422 UNIT A6 424 UNIT A1 576 UNIT A7 582 UNIT A1 577 UNIT B1 601 UNIT A1 578 UNIT A2 744 UNIT B1 603 UNIT A1 629 UNIT A3 748 UNIT A1 633 UNIT B6 700 UNIT BA1 593 STAIR 2 810 ELEC ROOM 759 ELEVATOR 1 1356 ELEVATOR 2 1355 BOH 412 RTU 1 RTU 2 RTU 3 CC C C C C 10x8 SA 10x8 RA 10x10 SA 10x10 RA 8x8 SA 8x8 SA 10x10 SA 8x8 SA 10x8 SA 10x10 RA UNIT B6 705 UNIT A6 536 SP 2 SP 3 SP 2 SP 3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:41:59 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.09B ALS SDW 2247601 LEVEL 9-10 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 9-10 -FLOOR PLAN -AREA B1 DATE DESCRIPTION REV STAIR 2 810 ELEC ROOM 759 RTU LR-1 RTU LR-2 RTU 9 RTU 10 TR LR-1 TR 2 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:42:08 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.09C ALS SDW 2247601 LEVEL 9 -LOW ROOF -FLOOR PLAN -AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" LEVEL 9 LOW ROOF -FLOOR PLAN -AREA C1 DATE DESCRIPTION REV RTU HR-4 RTU HR-5 RTU HR-6 RTU 4 RTU 5 RTU 6 RTU 7 RTU 8 RTU HR-8 RTU HR-7 AMENITY HEAT PUMPS AMENITY HEAT PUMPS SP 4 SP 5 SPF 4 S SPF 5S TR HR-1 TR 1 M DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:42:19 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.10A ALS SDW 2247601 ROOF PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" HIGH ROOF -AREA A1 DATE DESCRIPTION REV RTU 1 RTU HR-3 RTU 2 RTU 3 RTU HR-1 RTU HR-2 SP 2 SP 3 SPF 2 S SPF 3 S DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:42:29 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM02.10B ALS SDW 2247601 ROOF PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/8" = 1'-0" HIGH ROOF -AREA B1 DATE DESCRIPTION REV TT AHU A - 18x10C- 18x10C - 24x12C 12x10 SA R14x6A155 10x6A100 14x6A155 14x6A155 8x4B30 RRRRR R EF A 4"Ø 7"Ø 7"Ø 7"Ø 6"Ø 4Ø EA 4Ø EA 7 5 6 3 2 4 1 AHU A EF A - 18x10C- 18x10C - 24x12C 8x4B30 4Ø EA 4Ø EA 14x6A170 14x6A200 14x6A170 12x10 SA RR R RRRR 8x4B30 4"Ø 4"Ø 8"Ø 8"Ø 8"Ø 5 6 2 7 4 3 1 KEYNOTES 1. ELECTRICAL LOAD CENTER SHOWN FOR REFERENCE. AVOID ROUTING DUCTWORK OVER LOAD CENTER. 2. ROUTE 4"∅DRYER EXHAUST DUCT FROM DRYER EXHAUST WALL BOX UP IN WALL AND INTO TRUSS SPACE. FIRESTOP PENETRATION AT TOP PLATE. ROUTE EXHAUST DUCT TO EXTERIOR WALL CAP/SOFFIT GRILLE. REFER TO DRYER VENT LENGTH CALCULATION FOR QUANTITY AND TYPE OF ELBOWS. 3. DRYER MAKE-UP AIR -TWO (2) 18X10 TYPE "G" GRILLES; ONE ON EACH SIDE OF WALL CENTERED ABOVE THE DOOR TO PROVIDE A MINIMUM OF 120 SQUARE INCHES FREE AREA. IN ADDITION, UNDERCUT (BY OTHERS) LAUNDRY ROOM DOOR(S) 1" TO PROVIDE FOR HIGH/LOW MAKE-UP AIR. 1" UNDERCUT SHALL BE FROM TOP OF FINISHED FLOOR. 4. KITCHEN HOOD IS THE RECIRCULATING TYPE (WITH INTEGRAL BDD) PROVIDED BY OTHERS. 5. AIR HANDLING UNIT SHALL BE SHUT OFF UPON ACTIVATION OF THE FIRE STAT LOCATED IN THE AHU DUCT. PROVIDE ALL CONTROL WIRING AND INTERLOCK. 6. TRAP AND ROUTE PRIMARY CONDENSATE FULL SIZE OF UNIT CONNECTION (MIN. 3/4") TO HUB DRAIN IN MECHANICAL CLOSET (RE: PLUMBING DRAWINGS FOR LOCATION). REFER TO CONDENSATE TRAP AND DWELLING UNIT AIR HANDLING UNIT DETAILS FOR ADDITIONAL REQUIREMENTS. 7. REFRIGERANT PIPING RISERS. INDICATED ON PLAN AS APPLY TO THIS SHEET ONLY# DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:35:09 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM04.01 ALS SDW 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/4" = 1'-0" UNIT S21 Scale: 1/4" = 1'-0" UNIT A12 DATE DESCRIPTION REV T T AHU A - 18x10C 12x10 SA R- 18x10C - 24x12C 14x6A200 14x6A200 8x4B30 8x4B30 12x6A140 7"Ø 4"Ø 4"Ø 8"Ø 8"Ø R R RRREF A 4Ø EA4Ø EA 4 5 6 2 3 7 1 AHU A - 18x10C - 24x12C 12x10 SA R14x6A200 14x6A170 8x4B30 10x6A100 10x6A100 6"Ø 4"Ø 8"Ø 8"Ø 6"Ø RRRRR R 4Ø EA 4Ø EA EF A 5 6 7 2 3 4 1 KEYNOTES 1. ELECTRICAL LOAD CENTER SHOWN FOR REFERENCE. AVOID ROUTING DUCTWORK OVER LOAD CENTER. 2. ROUTE 4"∅DRYER EXHAUST DUCT FROM DRYER EXHAUST WALL BOX UP IN WALL AND INTO TRUSS SPACE. FIRESTOP PENETRATION AT TOP PLATE. ROUTE EXHAUST DUCT TO EXTERIOR WALL CAP/SOFFIT GRILLE. REFER TO DRYER VENT LENGTH CALCULATION FOR QUANTITY AND TYPE OF ELBOWS. 3. DRYER MAKE-UP AIR -TWO (2) 18X10 TYPE "G" GRILLES; ONE ON EACH SIDE OF WALL CENTERED ABOVE THE DOOR TO PROVIDE A MINIMUM OF 120 SQUARE INCHES FREE AREA. IN ADDITION, UNDERCUT (BY OTHERS) LAUNDRY ROOM DOOR(S) 1" TO PROVIDE FOR HIGH/LOW MAKE-UP AIR. 1" UNDERCUT SHALL BE FROM TOP OF FINISHED FLOOR. 4. KITCHEN HOOD IS THE RECIRCULATING TYPE (WITH INTEGRAL BDD) PROVIDED BY OTHERS. 5. AIR HANDLING UNIT SHALL BE SHUT OFF UPON ACTIVATION OF THE FIRE STAT LOCATED IN THE AHU DUCT. PROVIDE ALL CONTROL WIRING AND INTERLOCK. 6. TRAP AND ROUTE PRIMARY CONDENSATE FULL SIZE OF UNIT CONNECTION (MIN. 3/4") TO HUB DRAIN IN MECHANICAL CLOSET (RE: PLUMBING DRAWINGS FOR LOCATION). REFER TO CONDENSATE TRAP AND DWELLING UNIT AIR HANDLING UNIT DETAILS FOR ADDITIONAL REQUIREMENTS. 7. REFRIGERANT PIPING RISERS. INDICATED ON PLAN AS APPLY TO THIS SHEET ONLY# DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:35:18 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM04.02 ALS SDW 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/4" = 1'-0" UNIT A61 Scale: 1/4" = 1'-0" UNIT AD22 DATE DESCRIPTION REV TTAHU B - 18x10C- 18x10C- 24x12C 14x12 SAR EF A EF A 4Ø EA 14x6A150 14x6A170 14x6A150 14x6A170 8x4B30 14x6A100 8x4B30 RRRRRR R RR 4Ø EA 4Ø EA 4Ø EA 7"Ø 8"Ø 8"Ø 7"Ø 4"Ø 6"Ø 4"Ø 3 25 6 7 41 AHU B - 18x10C- 18x10C - 24x12C 14x12 SA R 4Ø EA 4Ø EA 4Ø EAEF A EF A 14x6A160 14x6A160 14x6A145 8x4B30 14x6A100 14x6A145 8x4B30 8x4B30 6"Ø8"Ø 8"Ø 7"Ø 4"Ø 7"Ø 4"Ø 4"Ø R R R R RRRRR 4Ø EA 5 6 7 3 2 4 1 KEYNOTES 1. ELECTRICAL LOAD CENTER SHOWN FOR REFERENCE. AVOID ROUTING DUCTWORK OVER LOAD CENTER. 2. ROUTE 4"∅DRYER EXHAUST DUCT FROM DRYER EXHAUST WALL BOX UP IN WALL AND INTO TRUSS SPACE. FIRESTOP PENETRATION AT TOP PLATE. ROUTE EXHAUST DUCT TO EXTERIOR WALL CAP/SOFFIT GRILLE. REFER TO DRYER VENT LENGTH CALCULATION FOR QUANTITY AND TYPE OF ELBOWS. 3. DRYER MAKE-UP AIR -TWO (2) 18X10 TYPE "G" GRILLES; ONE ON EACH SIDE OF WALL CENTERED ABOVE THE DOOR TO PROVIDE A MINIMUM OF 120 SQUARE INCHES FREE AREA. IN ADDITION, UNDERCUT (BY OTHERS) LAUNDRY ROOM DOOR(S) 1" TO PROVIDE FOR HIGH/LOW MAKE-UP AIR. 1" UNDERCUT SHALL BE FROM TOP OF FINISHED FLOOR. 4. KITCHEN HOOD IS THE RECIRCULATING TYPE (WITH INTEGRAL BDD) PROVIDED BY OTHERS. 5. AIR HANDLING UNIT SHALL BE SHUT OFF UPON ACTIVATION OF THE FIRE STAT LOCATED IN THE AHU DUCT. PROVIDE ALL CONTROL WIRING AND INTERLOCK. 6. TRAP AND ROUTE PRIMARY CONDENSATE FULL SIZE OF UNIT CONNECTION (MIN. 3/4") TO HUB DRAIN IN MECHANICAL CLOSET (RE: PLUMBING DRAWINGS FOR LOCATION). REFER TO CONDENSATE TRAP AND DWELLING UNIT AIR HANDLING UNIT DETAILS FOR ADDITIONAL REQUIREMENTS. 7. REFRIGERANT PIPING RISERS. INDICATED ON PLAN AS APPLY TO THIS SHEET ONLY# DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:35:28 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM04.03 ALS SDW 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/4" = 1'-0" UNIT B11 Scale: 1/4" = 1'-0" UNIT B22 DATE DESCRIPTION REV T AHU B - 18x10C- 18x10C - 24x12C R 4Ø EA 4Ø EA EF A 4Ø EA EF A 14x6A100 8x4B30 8x4B30 14x6A130 14x6A160 14x6A160 14x6A130 8x4B30 8x4B30 R RR R R R R R R RR 14x12 SA 4"Ø 6"Ø 4"Ø 7"Ø 8"Ø 8"Ø 7"Ø 4"Ø 4"Ø 5 6 7 3 2 4 1 KEYNOTES 1. ELECTRICAL LOAD CENTER SHOWN FOR REFERENCE. AVOID ROUTING DUCTWORK OVER LOAD CENTER. 2. ROUTE 4"∅DRYER EXHAUST DUCT FROM DRYER EXHAUST WALL BOX UP IN WALL AND INTO TRUSS SPACE. FIRESTOP PENETRATION AT TOP PLATE. ROUTE EXHAUST DUCT TO EXTERIOR WALL CAP/SOFFIT GRILLE. REFER TO DRYER VENT LENGTH CALCULATION FOR QUANTITY AND TYPE OF ELBOWS. 3. DRYER MAKE-UP AIR -TWO (2) 18X10 TYPE "G" GRILLES; ONE ON EACH SIDE OF WALL CENTERED ABOVE THE DOOR TO PROVIDE A MINIMUM OF 120 SQUARE INCHES FREE AREA. IN ADDITION, UNDERCUT (BY OTHERS) LAUNDRY ROOM DOOR(S) 1" TO PROVIDE FOR HIGH/LOW MAKE-UP AIR. 1" UNDERCUT SHALL BE FROM TOP OF FINISHED FLOOR. 4. KITCHEN HOOD IS THE RECIRCULATING TYPE (WITH INTEGRAL BDD) PROVIDED BY OTHERS. 5. AIR HANDLING UNIT SHALL BE SHUT OFF UPON ACTIVATION OF THE FIRE STAT LOCATED IN THE AHU DUCT. PROVIDE ALL CONTROL WIRING AND INTERLOCK. 6. TRAP AND ROUTE PRIMARY CONDENSATE FULL SIZE OF UNIT CONNECTION (MIN. 3/4") TO HUB DRAIN IN MECHANICAL CLOSET (RE: PLUMBING DRAWINGS FOR LOCATION). REFER TO CONDENSATE TRAP AND DWELLING UNIT AIR HANDLING UNIT DETAILS FOR ADDITIONAL REQUIREMENTS. 7. REFRIGERANT PIPING RISERS. INDICATED ON PLAN AS APPLY TO THIS SHEET ONLY# DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:35:35 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM04.04 ALS SDW 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: Scale: 1/4" = 1'-0" UNIT BA11 DATE DESCRIPTION REV NOTES: 1. GENERAL CONTRACTOR SHALL COORDINATE THE PLENUM RATING OF ALL MATERIALS IN THE HVAC CLOSET WITH ALL DISCIPLINES PRIOR TO CONSTRUCTION. 2. ALL MATERIALS, INCLUDING WIRING AND PIPING, IN THE UPPER CLOSET SHALL BE PLENUM RATED AS REQUIRED BY BUILDING CODE. 3. HVAC CLOSET MAY BE CONSTRUCTED OF COMBUSTIBLE MATERIALS WHERE PERMITTED BY BUILDING CODE. 4. GENERAL AND MECHANICAL CONTRACTORS SHALL CONFIRM ADEQUATE LAYOUT, ROUTING AND INSTALLATION OF ALL EQUIPMENT, PIPING AND SYSTEMS IN CLOSET WITH ALL DISCIPLINES PRIOR TO CONSTRUCTION. 5. AIR HANDLER SHALL BE INSTALLED SUCH THAT THE TOP OF THE AIR HANDLER SHALL NOT EXCEED THE TOP OF THE CLOSET DOOR OPENING. 6. CAREFULLY COORDINATE LOCATION OF CEILING RADIATION DAMPER ACCESS PRIOR TO CONSTRUCTION. 7. GENERAL CONTRACTOR SHALL COORDINATE FLOOR/ATTIC TRUSS LOCATIONS ABOVE CLOSET WITH PLUMBING AND MECHANICAL CONTRACTORS TO AVOID CONFLICTS WITH DUCTWORK AND PIPING. TRUSS SPACING MAY REQUIRE GREATER THAN 24" O.C. AT HVAC CLOSET. 8. PROVIDE SAFE-T-SWITCH CONDENSATE OVERFLOW SHUT-OFF SWITCH ON SECONDARY CONNECTION ON PRIMARY DRAIN PAN. 9. INTERLOCK NEAREST DWELLING UNIT SMOKE ALARM TO SHUTDOWN AIR HANDLER OPERATION. SEE INTERLOCK DETAIL FOR MORE INFORMATION. RIGID SUPPLY DUCTWORK SUPPLY FLEX DUCT CRD ACCESS DOOR OPTION 2 CRD ACCESS DOOR OPTION 1 REFRIGERANT LINE CONNECTIONS SECURE AIR HANDLER TO WALL WITH Z PANEL CLIPS/HANGERS AND ANGLE BRACKETS SEPARATION SHELF-1/4" THICK CEMENT BASED BACKER-BOARD MATERIAL (RE: ARCH. DWGS.) WITH ALL EDGES AND PENETRATIONS SEALED PRIMARY CONDENSATE DRAIN WITH TRAP, SEE TRAP DETAIL, SIZE PIPE TO MATCH PAN CONNECTION, 3/4" MIN. WATER HEATER DRAIN PAN UL LISTED AND APPROVED CEILING RADIATION DAMPER (CRD) AS REQUIRED TO COMPLY WITH F AND T RATINGS OF THE UL LISTED CEILING ASSEMBLY UL LISTED CEILING-FLOOR / CEILING ROOF ASSEMBLY, SEE ARCHITECTURAL DRAWINGS FOR UL INFORMATION AND DETAILS RETURN AIR GRILLE 4"x4" STEEL ELECTRICAL OUTLET BOX WITH 120V/24V RELAY -REFER TO AH/FURNACE SHUTDOWN WIRING DIAGRAM INTEGRAL 1" RETURN AIR FILTER RACK 1/2" THICK ELASTOMERIC INSULATION (AP ARMAFLEX) ADHERED TO THE SHELF ALONG ENTIRE LENGTH OF THE DOOR 7'-0" (MIN.) HIGH HVAC CLOSET DOOR SANITARY HUB DRAIN, REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION PROVIDE PROTECTIVE NAIL PLATE BEHIND WALL BOARD TO PROTECT REFRIGERANT PIPING REFRIGERANT PIPING FROM THIS AH MUST PENETRATE THE WALL BELOW THE STRUCTURE ABOVE SANITARY WASTE STACK SANITARY HUB DRAIN 32" DOOR MINIMUM (DOORWAY MUST PROVIDE MINIMUM OPENING WIDTH OF 29" CLEAR) SURFACE MOUNTED CEILING 4"x4" STEEL ELECTRICAL OUTLET BOX WITH 120V/24V RELAY -REFER TO AH/FURNACE SHUTDOWN WIRING DIAGRAM 36" DEEP x 40" WIDE CLOSET, MINIMUM, INSIDE CLEAR OF WALL BOARD ROUTE REFRIGERANT PIPING WITHIN WALL FRAMING, 6" WALL, MIN. PRIMARY CONDENSATE TRAP AND VENT AIR HANDLER FRAMING TRUSS, TYP. WATER HEATER AND DRAIN PAN WH 9" PLBG AREA AH SIDE ELEVATION VIEW PLAN VIEW NOTES: 1. GENERAL CONTRACTOR SHALL COORDINATE THE PLENUM RATING OF ALL MATERIALS IN THE HVAC CLOSET WITH ALL DISCIPLINES PRIOR TO CONSTRUCTION. 2. ALL MATERIALS, INCLUDING WIRING AND PIPING, IN THE UPPER CLOSET SHALL BE PLENUM RATED AS REQUIRED BY BUILDING CODE. 3. GENERAL AND MECHANICAL CONTRACTORS SHALL CONFIRM ADEQUATE LAYOUT, ROUTING AND INSTALLATION OF ALL EQUIPMENT, PIPING AND SYSTEMS IN CLOSET WITH ALL DISCIPLINES PRIOR TO CONSTRUCTION. 4. AIR HANDLER SHALL BE INSTALLED SUCH THAT THE TOP OF THE AIR HANDLER SHALL NOT EXCEED THE TOP OF THE CLOSET DOOR OPENING. 5. PROVIDE SAFE-T-SWITCH CONDENSATE OVERFLOW SHUT-OFF SWITCH ON SECONDARY CONNECTION ON PRIMARY DRAIN PAN. 6. SEE TYPICAL LINE SET CONCRETE SLAB OPENINGS DETAIL FOR MORE INFORMATION. RIGID SUPPLY DUCTWORK SUPPLY FLEX DUCT NON-RATED CEILING REFRIGERANT LINE CONNECTIONS SECURE AIR HANDLER TO WALL WITH Z PANEL CLIPS/HANGERS AND ANGLE BRACKETS SEPARATION SHELF-1/4" THICK CEMENT BASED BACKER- BOARD MATERIAL (RE: ARCH. DWGS.) WITH ALL EDGES AND PENETRATIONS SEALED PRIMARY CONDENSATE DRAIN WITH TRAP, SEE TRAP DETAIL, SIZE PIPE TO MATCH PAN CONNECTION, 3/4" MIN. WATER HEATER DRAIN PAN CONCRETE CEILING-FLOOR / CEILING-ROOF DECK, SEE ARCHITECTURAL DRAWINGS FOR UL INFORMATION AND DETAILS RETURN AIR GRILLE INTEGRAL 1" RETURN AIR FILTER RACK 1/2" THICK ELASTOMERIC INSULATION (AP ARMAFLEX) ADHERED TO THE SHELF ALONG ENTIRE LENGTH OF THE DOOR 7'-0" (MIN.) HIGH HVAC CLOSET DOOR SANITARY HUB DRAIN, REFER TO PLUMBING DRAWINGS FOR MORE INFORMATION PROVIDE PROTECTIVE NAIL PLATE BEHIND WALL BOARD TO PROTECT REFRIGERANT PIPING REFRIGERANT PIPING FROM THIS AH MUST PENETRATE THE WALL BELOW THE STRUCTURE ABOVE SANITARY WASTE STACK SANITARY HUB DRAIN 32" DOOR MINIMUM (DOORWAY MUST PROVIDE MINIMUM OPENING WIDTH OF 29" CLEAR) 40" DEEP x 40" WIDE CLOSET, MINIMUM, INSIDE CLEAR OF WALL BOARD SUGGESTED ALTERNATE AREA FOR ELECTRICAL CONDUCTORS TO OUTDOOR AC UNITS, IF REQUIRED - DESIGNER TO COORDINATE SIZE AND LOCATION ROUTE REFRIGERANT PIPING WITHIN WALL FRAMING, 6" WALL, MIN. PRIMARY CONDENSATE TRAP AND VENT AIR HANDLER WATER HEATER AND DRAIN PAN AH WH 9" PLBG AREA PLAN VIEW SIDE ELEVATION VIEW NOTE 1 TO OTHER SMOKE ALARMS (BY ELECTRICAL) WHITE (NEUTRAL ) BLACK (HOT) NOTE 3 AUXILIARY CONTACT (NO) WHITE (NEUTRAL) ORANGE (INTERCONNECT) BLACK (HOT) NOTE 2 BLUE (NOT USED) BROWN GRAY (NC) R C C R G G Y Y W W THERMOSTAT AH/FURNACE 24V/120V ALARM RELAY- FIRST ALERT (BRK) MODEL RM4 NOTES: 1. BREAK THE RED WIRE BETWEEN THE THERMOSTAT AND AH TERMINAL STRIP. 2. 4X4 STEEL ELECTRICAL OUTLET BOX -LABEL COVER "AH (OR FURNACE) SHUTDOWN RELAY" (BOTH THE BOX AND THE RELAY ARE TO BE FURNISHED BY MECHANICAL FOR INSTALLATION BY ELECTRICAL). 3. SMOKE ALARM (LAST IN SERIES) WITH AUXILIARY CONTACT (BY ELECTRICAL). SMOKE ALARM SHALL BE CAPABLE OF OPERATING THE AUXILIARY CONTACT WHILE BEING POWERED BY EITHER 9 OR 120 VOLTS. 4. THE 24V/120V ALARM RELAY MAY BE ELIMINATED IF A SMOKE ALARM HAVING THE SAME FEATURES IS PROVIDED. AIR HANDLER/FURNACE SHUTDOWN WIRING NOT TO SCALE OA INTAKE PER PLANS FILTER SECTION WITH SIDE ACCESS -MAINTAIN CLEAR SPACE FOR FILTER REMOVAL THREADED ROD WITH SPRING TYPE VIBRATION ISOLATORS (SIZE ROD AND SUPPORT UNIT AS RECOMMENDED BY MANUFACTURER) (TYPICAL OF FOUR - ONE PER CORNER). SEE NOTE 1 FLEXIBLE DUCT CONNECTOR, TYP.M MVD LINED SUPPLY AIR DUCT (OR DUCT BOARD IF SPECIFIED) PRIMARY CONDENSATE DRAIN -FULL SIZE OF UNIT CONNECTION (3/4" MIN.) UNLESS NOTED OTHERWISE. SLOPE 1/8" PER FT. (OR SLOPE PER LOCAL CODE) MIN. -REFER TO FLOOR PLANS FOR ROUTING CONDENSATE TRAP PER DETAIL CONDENSATE SAFETY SWITCH IN OVERFLOW DRAIN; "SAFE-T-SWITCH" OR EQUAL. INTERLOCK WITH AH TO SHUT UNIT OFF IF LIQUID IS DETECTED LINED RETURN AIR PLENUM/ DUCTWORK (OR DUCT BOARD IF SPECIFIED) AUXILIARY DRAIN PAN WITH WATER LEVEL DETECTION DEVICE WIRED TO SHUT DOWN THE UNIT IF LIQUID IS PRESENT (PER 2012, 2015, OR 2018 IMC 307.2.3, METHOD 3 -SEE NOTE 5) NOTES: 1. STRUCTURE VARIES. COORDINATE WITH STRUCTURAL DOCUMENTS FOR PROPER ANCHORING METHOD (BEAM CLAMPS, EXPANSION BOLTS, INSERTS, ETC.). 2. ON SERVICE SIDE OF UNIT, MAINTAIN A 42"W X LENGTH OF UNIT CLEARANCE TO PIPING, DUCTWORK, EQUIPMENT, CONDUIT, ETC. ELECTRIC HEAT SECTIONS OR DUCT HEATERS: MAINTAIN A MIN. OF 42" CLEARANCE (OR PER N.E.C.) IN FRONT OF ALL ELECTRIC HEATER CONTROL PANELS. THE WIDTH OF THE SERVICE CLEARANCE SHALL BE 30" OR THE WIDTH OF THE PANEL WHICHEVER IS GREATER. FOR LOW VOLTAGE CONTROL PANELS (WITHOUT ELECTRIC HEATER), MAINTAIN A MIN. OF 24" CLEARANCE (OR PER N.E.C.) IN FRONT OF PANEL. THE WIDTH OF THE SERVICE CLEARANCE SHALL BE 24" OR THE WIDTH OF THE PANEL WHICHEVER IS GREATER. NO PIPES, SPRINKLERS, CONDUITS, ETC. SHALL BE INSTALLED WITHIN THIS ZONE. COORDINATE AND PLAN WORK CAREFULLY WITH ALL OTHER TRADES. 3. WHERE AHs OR THEIR WORKING CLEARANCE ARE LOCATED ABOVE LIGHT FIXTURES, THE FIXTURE SHALL HAVE A FLEXIBLE WHIP TO ALLOW TEMPORARY RELOCATION OF THE FIXTURE FOR ACCESS TO THE AH. COORDINATE WITH ELECTRICAL CONTRACTOR. 4. PROVIDE MINIMUM SERVICE CLEARANCES AS RECOMMENDED BY UNIT MANUFACTURER. 5. AUXILIARY DRAIN PAN WITHOUT DRAIN LINE -WATER-LEVEL DETECTION DEVICE SHALL CONFORM TO UL 508. THE PAN SHALL HAVE A MINIMUM DEPTH OF 1 1/2 INCHES (38 MM), SHALL BE NOT LESS THAN 3 INCHES (76 MM) LARGER THAN THE UNIT IN WIDTH AND LENGTH AND SHALL BE CONSTRUCTED OF CORROSION-RESISTANT MATERIAL. GALVANIZED SHEET STEEL PANS SHALL HAVE A MINIMUM THICKNESS OF NOT LESS THAN 0.0236 INCHES (0.6010 MM) (NO. 24 GAGE). 6. REFER TO STRUCTURAL FOR FLOOR SYSTEM TYPE. 7. IF FILTER ACCESS IS FROM BOTTOM, INSTALL DRAIN PAN SO THAT ACCESS TO FILTER IS NOT BLOCKED MVD SUSPENDED HORIZONTAL AIR HANDLING UNIT DETAIL NOT TO SCALE 0' - 1 1/8" 4 5 .0 °45.0° MIN. 24 GAUGE VANES 0' - 2 1/4" 45.0°4 5 .0 ° MIN. 26 GAUGE VANES 4-1/2"R 2"R TYPE 2 RUNNER WELD EVERY SIXTH VANE TO RUNNER (OVER 1500 FPM) LARGE SMALL NOTE: 1. TURNING VANES SHALL BE CONSTRUCTED PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS (2005 EDITION FIGURE 4-3).0' - 2 1/8"0' - 3 1/4"TURNING VANE DETAIL NOT TO SCALE 3 1/2"2" PIANO HINGE, 16 GAUGE, REVERSE ASSEMBLY -SHIM AS REQUIRED ACCESS DOOR: 6"Ø -12"Ø DUCT: 4"x7" DOOR OPENING 13"Ø -26"Ø DUCT: 6"x9" DOOR OPENING STIFFENER PLATE WELDED TO DOOR DESTACO MODEL 2002 LOCKING CLAMP -TYP. OF 2 1/8" x 5/8" CLOSED CELL NEOPRENE GASKET - CONTINUOUS AROUND PERIMETER OF DOOR NOTES: 1. AS AN ALTERNATE, FACTORY FABRICATED CONTOURED DOOR WITH CLAMPING TYPE CLOSURE IS ACCEPTABLE; RUSKIN MODEL ADR OR APPROVED EQUAL. 2. ACCESS DOORS FOR FIRE DAMPERS, COMBINATION FIRE/SMOKE DAMPERS AND SMOKE DAMPERS IN MEDIUM PRESSURE (+4 IN. WG AND HIGHER) DUCT SYSTEMS SHALL BE THE IMPLOSION/PRESSURE RELIEF TYPE DESIGNED TO PREVENT EXCESSIVE NEGATIVE PRESSURE DOWNSTREAM RESULTING IN COLLAPSED DUCTWORK. AT THE CONTRACTOR'S OPTION, THE ACCESS DOOR MAY BE AN INTEGRAL FEATURE OF THE DAMPER ASSEMBLY. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:35:40 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM05.01 ALS SDW 2247601 DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 12" = 1'-0" DWELLING UNIT VERTICAL AIR HANDLING UNIT DETAIL (WOOD)1Scale: 12" = 1'-0" DWELLING UNIT VERTICAL AIR HANDLING UNIT DETAIL (CONCRETE)2Scale: 12" = 1'-0" AIR HANDLER/ FURNACE SHUTDOWN WIRING3 Scale: 12" = 1'-0" SUSPENDED HORIZONTAL AIR HANDLING UNIT DETAIL4 Scale: 6" = 1'-0" TURNING VANE DETAIL5Scale: 12" = 1'-0" DUCT ACCESS DOOR DETAIL6 CONNECT FLEX DUCT TO DIFFUSER NECK WITH NYLON ZIP TIES. APPLY A BEAD OF MASTIC BETWEEN THE INTERIOR LINER AND THE SHEET-METAL PRIOR TO ZIP-TYING. THE INTERIOR LINER AND EXTERIOR INSULATION OF THE FLEX DUCT SHALL BE ZIP-TIED INDIVIDUALLY. INSTALL ZIP TIES USING A TENSIONING TOOL PER MANUFACTURER'S RECOMMENDATION SECURE THERMAL INSULATION BLANKET TO DIFFUSER NECK/ CRD PER UL INSTALLATION INSTRUCTIONS SECURE CRD TO DIFFUSER NECK PER UL INSTALLATION INSTRUCTIONS NOTES: 1. CRDs SHALL BE CLASSIFIED IN ACCORDANCE WITH UL555C AND LABELED FOR A 1 HOUR FIRE RESISTANCE RATING. 2. SUPPORT CRD/DIFFUSER PER UL INSTALLATION INSTRUCTIONS. FLEXIBLE SUPPLY RUN OUT (OR RIGID SHEET- METAL ELBOW) EXTENDED DAMPER FRAME (REQUIRED ONLY WHEN USING FLEX DUCT) DAMPER BLADE 165°F FUSIBLE LINK CEILING RADIATION DAMPER THERMAL INSULATION BLANKET FURNISHED WITH DIFFUSER STEEL CEILING DIFFUSER UL CEILING ASSEMBLY WOOD TRUSS (RE: ARCH. DWGS. FOR LOCATIONS AND TYPE) DAMPER ASSEMBLY WITH R-6.5 INSULATED (R-8.0 IF LOCATED IN ATTIC) SHEET-METAL BOOT SIDE OR TOP CONNECTION AS REQUIRED SUPPLY RUN OUT 165°F FUSIBLE LINK SPRING RELEASE SECURE SUPPLY REGISTER TO DAMPER ASSEMBLY WITH SCREWS PER UL INSTALLATION INSTRUCTIONS CEILING RADIATION DAMPER -SEE UL ASSEMBLY DETAIL FOR TYPE AND RATING SUPPLY REGISTER OR GRILLE MOUNTING RAILS PER UL INSTALLATION INSTRUCTIONS NOTES: 1. CRDs SHALL BE CLASSIFIED IN ACCORDANCE WITH UL555C AND LABELED FOR A 1 HOUR FIRE RESISTANCE RATING. 2. INSULATION SHALL HAVE THE R-VALUE AS NOTED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS OR A MINIMUM R-VALUE OF 6.0. CEILING RADIATION DAMPER DETAIL NOT TO SCALE FD FREE AREA SHALL BE EQUAL TO THE FREE AREA OF THE SR/RAG -TRANSITION DUCTWORK AS REQUIRED (SEE NOTE 4) FIRE DAMPER ASSEMBLY -RUSKIN DIBD2G OR EQUAL. INSTALLATION SHALL CONFORM TO UL INSTALLATION INSTRUCTIONS FOR THE PARTICULAR DAMPER USED REGISTER OR GRILLE MOUNTING FLANGE SUPPLY REGISTER (DOUBLE DEFLECTION) WITH FACE OPERATED OBD OR RAG (MAX. DEPTH OF 2 7/8") -SEE PLANS FOR SIZE MOUNTING ANGLE -MINIMUM 1 1/2" x 1 1/2" x 20 GAUGE BOLTED, TACK WELDED OR SCREWED TO SLEEVE. SPACE FASTENERS PER UL INSTALLATION INSTRUCTIONS. RUSKIN "FAST" ANGLE IS AN ACCEPTABLE ALTERNATIVE 20 GAUGE STEEL SLEEVE -LENGTH PER UL INSTALLATION INSTRUCTIONS (SEE NOTE 5) BREAKAWAY CONNECTION NOTES: 1. FDs SHALL HAVE A RATING COMPATIBLE WITH THE FLOOR, WALL OR PARTITION, SHALL BE TESTED IN ACCORDANCE WITH UL555 AND BE LABELED FOR THE INTENDED LOCATION. UNLESS NOTED OTHERWISE, FDs SHALL BE RATED FOR 1 1/2 HOURS. COORDINATE WITH ARCHITECTURAL DRAWINGS TO CONFIRM RATINGS. 2. REFER TO ARCHITECTURAL DRAWINGS FOR WALL MATERIALS (WOOD OR METAL STUD, SHAFTWALL, ETC.) AND USE APPROPRIATE UL INSTALLATION INSTRUCTIONS TO SUIT APPLICATION. 3. IN WOOD CONSTRUCTION, GYPSUM WALLBOARD MUST COVER ALL WOOD STUD SURFACES. REFER TO UL INSTALLATION DETAILS FOR EXACT REQUIREMENTS. 4. ALTERNATE ASSEMBLY -OUT OF WALL TYPE -RUSKIN MODEL OW WITH BLADE STACK OUT OF THE AIR STREAM. USING THIS MODEL MAY NOT REQUIRE A DUCT TRANSITION. 5. DAMPER SETBACK (S) SHALL BE 3". SLEEVE LENGTH (L) IS CALCULATED AS FOLLOWS: S + 6"; THEREFORE 3" + 6" = 9" MINIMUM SLEEVE LENGTH. THE MINIMUM WALL DEPTH REQUIRED FOR RUSKIN MODEL DIBD2G IS CALCULATED AS FOLLOWS: S + 2"; THEREFORE 3" + 2" = 5" MINIMUM WALL DEPTH. IF THE WALL, FLOOR OR CEILING DEPTH IS LESS THAN THE CALCULATED MINIMUM, USE RUSKIN MODEL OW OR GA. FIRE CONDITION -WHEN TEMPERATURES IN EXCESS OF 165°F ARE PRESENT, THE DAMPER SHALL CLOSE. OPERATION SLEEVE LENGTH "L" WALL DUCT (SEE PLANS FOR SIZE) FRONT ACCESS FIRE DAMPER DETAIL NOT TO SCALE 3/4" REGISTER MOUNTING FLANGE ACTUATOR AND ACCESSORY ACCESS THROUGH GRILLE REMOVAL DUCT CONNECTION STEEL SUPPLY REGISTER WITH FACE OPERATED DAMPER (SINGLE DEFLECTION; MAXIMUM 2 1/2" DEPTH) OR STEEL RETURN AIR GRILLE. SIZE TO MATCH OVERALL W x H OF FSD ASSEMBLY (RE: PLANS FOR SIZE) ELECTRIC RESET LINK (RUSKIN EFL-165ºF) FOR CONNECTION TO SMOKE ALARM SIGNAL (COORDINATE WITH ELECTRICAL) BREAKAWAY CONNECTION OPERATOR/ACTUATOR (SIDE MOUNT) DUCT (SEE PLANS FOR SIZE) 1/4" THICK FACTORY APPLIED HIGH TEMPERATURE INSULATION (ALL FOUR SIDES OF DAMPER AND SLEEVE ASSEMBLY) 8" MAXIMUM FOR STEEL STUD AND MASONRY WALLS; 6" MAXIMUM FOR WOOD STUD WALLS (OR PER UL INSTALLATION INSTRUCTIONS) COMBINATION FIRE/SMOKE DAMPER ASSEMBLY - RUSKIN FSD 60GA OR EQUAL. INSTALLATION SHALL CONFORM TO THE UL INSTALLATION INSTRUCTIONS FOR THE PARTICULAR DAMPER USED STEEL SUPPLY REGISTER WITH FACE OPERATED DAMPER (SINGLE DEFLECTION, MAXIMUM 2 1/2" DEPTH) OR STEEL RETURN AIR GRILLE DAMPER AND ACTUATOR LOCATION SHALL ALLOW FLUSH INSTALLATION OF SUPPLY REGISTER (GRILLE AND OBD) -COORDINATE WITH THE DAMPER MANUFACTURER PRIOR TO ORDERING 3/4" FLANGE WALL OR PARTITION MOUNTING ANGLE -MINIMUM 1 1/2"x1 1/2"x14 GAUGE BOLTED, TACK WELDED OR SCREWED. SPACE FASTENERS PER UL INSTALLATION INSTRUCTIONS OPERATION/ACTUATION: SLEEVE OF SAME GAUGE AS DUCTWORK (MINIMUM) 1. FIRE CONDITION -WHEN TEMPERATURES IN EXCESS OF 165°F ARE DETECTED, THE DAMPER SHALL CLOSE VIA AN ELECTRIC FUSE LINK (EFL). THE EFL WILL ALLOW THE DAMPER TO AUTOMATICALLY REOPEN AFTER A TEST, SMOKE DETECTION OR POWER FAILURE. 2. SMOKE CONDITION -WHEN A SMOKE SIGNAL FROM THE SMOKE DETECTOR IS RECEIVED (AND TRANSMITTED TO THE FIRE ALARM SYSTEM), THE DAMPER SHALL CLOSE AND REMAIN CLOSED UNTIL THE SMOKE SIGNAL CEASES AND THE FIRE ALARM SYSTEM IS RESET. THE DAMPER SHALL THEN OPEN. 3. COMBINATION FIRE SMOKE DAMPER ACTUATION IN MULTIFAMILY AND HOTEL CORRIDOR SUPPLY AIR SYSTEMS SHALL OCCUR FROM A CEILING MOUNTED SMOKE DETECTOR (RE: ELECTRICAL DRAWING) IN THE CORRIDOR DIRECTLY ABOVE THE FSD FOR LOCAL ACTUATION. 4. COMBINATION FIRE SMOKE DAMPER ACTUATION IN HOTEL GUESTROOM OUTSIDE AIR SUPPLY AIR SYSTEMS SHALL OCCUR FROM A FIRE ALARM SYSTEM-TYPE SMOKE DETECTOR (WITH SOUNDER BASE AND AUXILIARY CONTACT; RE:ELECTRICAL DRAWING) IN THE GUESTROOM, TIED TO ITS RESPECTIVE SMOKE DAMPER. THIS DETECTOR WOULD BE IN LIEU OF THE 120V SMOKE ALARM, WHICH IS COMMON FOR HOTEL GUESTROOMS. 5. IF THE FSD IS INSTALLED IN A SMOKE MANAGEMENT SYSTEM, THE PRIMARY ACTUATION CONTROL SHALL BE FROM THE SMOKE CONTROL SYSTEM AND NOT THE CEILING SMOKE DETECTOR. 6. PROVIDE ALL REQUIRED ACCESSORIES FOR TESTING AND INSPECTION. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. NOTES: 1. IF THE FIRE/SMOKE DAMPERS ARE INSTALLED AS PART OF AN ENGINEERED SMOKE MANAGEMENT SYSTEM, REFER TO DUCTWORK AND ACCESSORIES SPECIFICATION FOR ACCESSORIES AND ADDITIONAL REQUIREMENTS. 2. FSDs SHALL HAVE A RATING COMPATIBLE WITH THE FLOOR, WALL OR PARTITION, SHALL BE TESTED IN ACCORDANCE WITH UL555 AND UL555S, AND BE LABELED FOR THE INTENDED LOCATION. UNLESS NOTED OTHERWISE, FSDs SHALL BE RATED FOR 1 1/2 HOURS AND LEAKAGE CLASS 1. COORDINATE WITH ARCHITECTURAL DRAWINGS TO CONFIRM WALL RATINGS. 3. IN WOOD CONSTRUCTION, GYPSUM WALLBOARD MUST COVER ALL WOOD STUD SURFACES. REFER TO UL INSTALLATION DETAILS FOR EXACT REQUIREMENTS. MAXIMUM 16" GRILLE ACCESS FIRE SMOKE DAMPER DETAIL NOT TO SCALE FIRE DAMPER ASSEMBLY; DYNAMIC CURTAIN TYPE, STYLE B, RUSKIN DIBD2 OR EQUAL. INSTALLATION SHALL CONFORM TO THE UL INSTALLATION INSTRUCTIONS FOR THE PARTICULAR DAMPER USED 165°F FUSIBLE LINK UNO DUCT (RE: PLANS FOR SIZE) SLEEVE OF SAME GAUGE AS DUCTWORK (MIN.) MOUNTING ANGLE -MINIMUM 1 1/2"x1 1/2"x14 GAUGE BOLTED, TACK WELDED OR SCREWED. SPACE FASTENERS PER UL INSTALLATION INSTRUCTIONS NOTES: 1. STYLE A (BLADE STACK IN THE AIR STREAM) WILL BE CONSIDERED AS AN ALTERNATE ONLY IF THERE IS INSUFFICIENT SPACE TO MOUNT THE STYLE B DAMPER. SUBMIT SUPPORTING DATA FOR ENGINEER'S REVIEW. 2. FDs SHALL HAVE A RATING COMPATIBLE WITH THE WALL OR PARTITION, SHALL BE TESTED IN ACCORDANCE WITH UL555 AND BE LABELED FOR THE INTENDED LOCATION. FDs SHALL BE RATED FOR 1 1/2 HOURS UNO. COORDINATE WITH ARCHITECTURAL DRAWINGS TO CONFIRM RATINGS. 3. IN WOOD CONSTRUCTION, GYPSUM WALLBOARD MUST COVER ALL WOOD STUD SURFACES. REFER TO UL INSTALLATION INSTRUCTIONS FOR EXACT REQUIREMENTS. 4. ACCESS DOOR SHALL BE IN AN ACCESSIBLE LOCATION AND ARRANGED SUCH THAT THE FD CAN BE INSPECTED AND THE FUSIBLE LINK EASILY REPLACED. ACCESS DOORS MAY BE FACTORY MOUNTED. ACCESS DOORS IN MEDIUM PRESSURE (+4 IN. WG AND HIGHER) DUCT SYSTEMS SHALL BE THE IMPLOSION TYPE. WALL OR PARTITION BREAKAWAY CONNECTION ACCESS DOOR-SEE NOTE 4 VERTICAL FIRE DAMPER DETAIL (2-HOUR) NOT TO SCALE DUCT (RE: PLANS FOR SIZE) ACCESS DOOR ACCESS DOOR & DUCT SMOKE DETECTOR - SEE DETAIL NOTES 4 & 5 OPERATOR/ ACTUATOR BREAKAWAY CONNECTION UL RATED FLOOR/ CEILING ASSEMBLY ELECTRIC RESET LINK (RUSKIN EFL-165º) FOR CONNECTION TO SMOKE ALARM SIGNAL (COORDINATE WITH ELECTRICAL) SLEEVE OF SAME GAUGE AS DUCTWORK (MINIMUM) COMBINATION FIRE/SMOKE DAMPER ASSEMBLY: RUSKIN FSD60 OR EQUAL. INSTALLATION SHALL CONFORM TO UL INSTALLATION INSTRUCTIONS FOR PARTICULAR DAMPER USED MOUNTING ANGLE -MINIMUM 1 1/2"x1 1/2"x14 GAUGE BOLTED, TACK WELDED OR SCREWED. SPACE FASTENERS PER UL INSTALLATION INSTRUCTIONS OPERATION/ACTUATION: 1. FIRE CONDITION -WHEN TEMPERATURES IN EXCESS OF 165°F ARE DETECTED, THE DAMPER SHALL CLOSE VIA AN ELECTRIC FUSE LINK (EFL). THE EFL WILL ALLOW THE DAMPER TO AUTOMATICALLY REOPEN AFTER A TEST, SMOKE DETECTION OR POWER FAILURE. 2. SMOKE CONDITION -WHEN A SMOKE SIGNAL FROM THE DUCT MOUNTED SMOKE DETECTOR IS RECEIVED (AND TRANSMITTED TO THE FIRE ALARM SYSTEM), THE DAMPER SHALL CLOSE AND REMAIN CLOSED UNTIL THE SMOKE SIGNAL CEASES AND THE FIRE ALARM SYSTEM IS RESET. THE DAMPER SHALL THEN OPEN. 3. IF THE FSD IS INSTALLED IN A SMOKE MANAGEMENT SYSTEM, THE PRIMARY ACTUATION CONTROL SHALL BE FROM THE SMOKE CONTROL SYSTEM AND NOT THE CEILING SMOKE DETECTOR. 4. PROVIDE ALL REQUIRED ACCESSORIES FOR TESTING AND INSPECTION. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. NOTES: 1. IF THE FSDs ARE INSTALLED AS PART OF AN ENGINEERED SMOKE MANAGEMENT SYSTEM, REFER TO DUCTWORK AND ACCESSORIES SPECIFICATION FOR ACCESSORIES AND ADDITIONAL REQUIREMENTS. 2. FSDs SHALL HAVE A RATING COMPATIBLE WITH THE FLOOR OR CEILING ASSEMBLY, SHALL BE TESTED IN ACCORDANCE WITH UL555 AND UL555S, AND BE LABELED FOR THE INTENDED LOCATION (HORIZONTAL IN FLOOR / CEILING ASSEMBLY). UNLESS NOTED OTHERWISE, FSDs SHALL BE RATED FOR 1 1/2 HOURS AND LEAKAGE CLASS 1. COORDINATE WITH ARCHITECTURAL DRAWINGS TO CONFIRM RATINGS. 3. IN WOOD CONSTRUCTION, GYPSUM WALLBOARD MUST COVER ALL WOOD STUD SURFACES. REFER TO UL INSTALLATION INSTRUCTIONS FOR EXACT REQUIREMENTS. 4. PROVIDE AN ACCESS DOOR FOR ALL FSDs. DUCT SMOKE DETECTORS (WITH ADDRESSABLE MODULE, IF REQUIRED) SHALL BE PROVIDED FOR ALL FSDs UNO. ACCESS DOORS MAY BE FACTORY MOUNTED. ACCESS DOORS IN MEDIUM PRESSURE (+4 IN. WG AND HIGHER) DUCT SYSTEMS SHALL BE THE IMPLOSION TYPE. 5. DUCT SMOKE DETECTOR SHALL BE COMPATIBLE WITH THE FIRE ALARM SYSTEM. COORDINATE WITH ELECTRICAL SUBCONTRACTOR. SLEEVE OF SAME GAUGE AS DUCTWORK (MINIMUM) DUCT (RE: PLANS FOR SIZE) COMBINATION FIRE/SMOKE DAMPER ASSEMBLY; RUSKIN FSD60 OR EQUAL. INSTALLATION SHALL CONFORM TO UL INSTALLATION INSTRUCTIONS FOR PARTICULAR DAMPER USED ELECTRIC RESET LINK (RUSKIN EFL-165°F) FOR CONNECTION TO SMOKE ALARM SIGNAL (COORDINATE WITH ELECTRICAL) OPERATOR/ACTUATOR ACCESS DOOR & DUCT SMOKE DETECTOR - SEE DETAIL NOTES 4 & 5 MOUNTING ANGLE -MINIMUM 1 1/2"x1 1/2"x14 GAUGE BOLTED, TACK WELDED OR SCREWED. SPACE FASTENERS PER UL INSTALLATION INSTRUCTIONS WALL OR PARTITION BREAKAWAY CONNECTION OPERATION/ACTUATION: 1. FIRE CONDITION -WHEN TEMPERATURES IN EXCESS OF 165°F ARE DETECTED, THE DAMPER SHALL CLOSE VIA AN ELECTRIC FUSE LINK (EFL). THE EFL WILL ALLOW THE DAMPER TO AUTOMATICALLY REOPEN AFTER A TEST, SMOKE DETECTION OR POWER FAILURE. 2. SMOKE CONDITION -WHEN A SMOKE SIGNAL FROM THE DUCT MOUNTED SMOKE DETECTOR IS RECEIVED (AND TRANSMITTED TO THE FIRE ALARM SYSTEM), THE DAMPER SHALL CLOSE AND REMAIN CLOSED UNTIL THE SMOKE SIGNAL CEASES AND THE FIRE ALARM SYSTEM IS RESET. THE DAMPER SHALL THEN OPEN. 3. IF THE FSD IS INSTALLED IN A SMOKE MANAGEMENT SYSTEM, THE PRIMARY ACTUATION CONTROL SHALL BE FROM THE SMOKE CONTROL SYSTEM AND NOT THE DUCT SMOKE DETECTOR. 4. PROVIDE ALL REQUIRED ACCESSORIES FOR TESTING AND INSPECTION. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. NOTES: 1. IF THE FSDs ARE INSTALLED AS PART OF AN ENGINEERED SMOKE MANAGEMENT SYSTEM, REFER TO DUCTWORK AND ACCESSORIES SPECIFICATION FOR ACCESSORIES AND ADDITIONAL REQUIREMENTS. 2. FSDs SHALL HAVE A RATING COMPATIBLE WITH THE FLOOR OR CEILING ASSEMBLY, SHALL BE TESTED IN ACCORDANCE WITH UL555 AND UL555S, AND BE LABELED FOR THE INTENDED LOCATION (HORIZONTAL IN FLOOR/CEILING ASSEMBLY). UNLESS NOTED OTHERWISE, FSDs SHALL BE RATED FOR 11/2 HOURS AND LEAKAGE CLASS 1. COORDINATE WITH ARCHITECTURAL DRAWINGS TO CONFIRM RATINGS. 3. IN WOOD CONSTRUCTION, GYPSUM WALLBOARD MUST COVER ALL WOOD STUD SURFACES. REFER TO UL INSTALLATION INSTRUCTIONS FOR EXACT REQUIREMENTS. 4. PROVIDE AN ACCESS DOOR FOR ALL FSDs. DUCT SMOKE DETECTORS (WITH ADDRESSABLE MODULE, IF REQUIRED) SHALL BE PROVIDED FOR ALL FSDs UNO. ACCESS DOORS MAY BE FACTORY MOUNTED. ACCESS DOORS IN MEDIUM PRESSURE (+4 IN. WG AND HIGHER) DUCT SYSTEMS SHALL BE THE IMPLOSION TYPE. 5. DUCT SMOKE DETECTOR SHALL BE COMPATIBLE WITH THE FIRE ALARM SYSTEM. COORDINATE WITH ELECTRICAL SUBCONTRACTOR. VERTICAL FIRE SMOKE DAMPER DETAIL NOT TO SCALE DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:35:46 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM05.02 ALS SDW 2247601 DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 12" = 1'-0" CEILING DIFFUSER WITH CRD DETAIL1Scale: 12" = 1'-0" CEILING RADIATION DAMPER DETAIL2 Scale: 12" = 1'-0" FRONT ACCESS FIRE DAMPER DETAIL3 Scale: 1/8" = 1'-0" GRILLE ACCESS FIRE SMOKE DAMPER DETAIL4Scale: 12" = 1'-0" VERTICAL FIRE DAMPER DETAIL (2-HOUR)5Scale: 12" = 1'-0" HORIZONTAL FIRE/SMOKE DAMPER DETAIL6Scale: 12" = 1'-0" VERTICAL FIRE SMOKE DAMPER DETAIL7 FIRE DAMPER ASSEMBLY; DYNAMIC CURTAIN TYPE, STYLE B, RUSKIN DIBD2 OR EQUAL. INSTALLATION SHALL CONFORM TO THE UL INSTALLATION INSTRUCTIONS FOR THE PARTICULAR DAMPER USED SLEEVE OF SAME GAUGE AS DUCTWORK (MIN.) MOUNTING ANGLE -MINIMUM 1 1/2"x1 1/2"x14 GAUGE BOLTED, TACK WELDED OR SCREWED. SPACE FASTENERS PER UL INSTALLATION INSTRUCTIONS ACCESS DOOR - SEE NOTE 4 WALL OR PARTITION BREAKAWAY CONNECTION DUCT (RE: PLANS FOR SIZE) 165°F FUSIBLE LINK UNO NOTES: 1. STYLE A (BLADE STACK IN THE AIR STREAM) WILL BE CONSIDERED AS AN ALTERNATE ONLY IF THERE IS INSUFFICIENT SPACE TO MOUNT THE STYLE B DAMPER. SUBMIT SUPPORTING DATA FOR ENGINEER'S REVIEW. 2. FDs SHALL HAVE A RATING COMPATIBLE WITH THE FLOOR, SHALL BE TESTED IN ACCORDANCE WITH UL555 AND BE LABELED FOR THE INTENDED LOCATION. FDs SHALL BE RATED FOR 11/2 HOURS UNO. COORDINATE WITH ARCHITECTURAL DRAWINGS TO CONFIRM RATINGS. 3. IN WOOD CONSTRUCTION, GYPSUM WALLBOARD MUST COVER ALL WOOD STUD SURFACES. REFER TO UL INSTALLATION INSTRUCTIONS FOR EXACT REQUIREMENTS. 4. ACCESS DOOR SHALL BE IN AN ACCESSIBLE LOCATION AND ARRANGED SUCH THAT THE FD CAN BE INSPECTED AND THE FUSIBLE LINK EASILY REPLACED. ACCESS DOORS MAY BE FACTORY MOUNTED. ACCESS DOORS IN MEDIUM PRESSURE (+4 IN. WG AND HIGHER) DUCT SYSTEMS SHALL BE THE IMPLOSION TYPE. HORIZONTAL FIRE DAMPER DETAIL NOT TO SCALE RECTANGULAR SUPPLY, RETURN OR EXHAUST DUCT MVD RECTANGULAR BRANCH DUCT TAKE-OFF L=1/4W, 4" MIN. SA AIRFLOWRA & EA AIRFLOWROUND BRANCH DUCT TAKE-OFF CONICAL TAP (SPIN-IN OR FLANGED) SHOP FABRICATED 45° CONICAL FITTING SHOP FABRICATED 90° CONICAL FITTING NOTE: 1. ACCEPTABLE ALTERNATIVES ARE CONICAL TAPS AND CONICAL SADDLE TAPS PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS. NOTE: 1. ACCEPTABLE ALTERNATIVES ARE CONICAL TAPS AND CONICAL SADDLE TAPS PER SMACNA HVAC DUCT CONSTRUCTION STANDARDS. LOW PRESSURE BRANCH DUCT TAKE-OFF (RECTANGULAR 45° ENTRY) LOW PRESSURE BRANCH DUCT TAKE-OFF ROUND BRANCH ENTRY) LOW PRESSURE BRANCH DUCT TAKE-OFF (ALTERNATIVE ROUND 90° BRANCH) LOW PRESSURE BRANCH DUCT TAKE-OFF (ALTERNATIVE ROUND 45° ENTRY) MVD RECTANGULAR SUPPLY, RETURN OR EXHAUST DUCT SA AIRFLOWRA & EA AIRFLOWSA AIRFLOW RA & EA AIRFLOW SA AIRFLOW RA & EA AIRFLOWWL BRANCH DUCT TAKE-OFF DETAILS NOT TO SCALE CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH ZIP TIES. APPLY A BEAD OF MASTIC BETWEEN THE INTERIOR LINER AND THE SHEET METAL PRIOR TO ZIP-TYING. THE INTERIOR LINER AND EXTERIOR INSULATION OF THE FLEX DUCT SHALL BE ZIP-TIED INDIVIDUALLY ZIP TIES INTERIOR LINER PRE-INSULATED FLEXIBLE DUCTWORK. SEE CENTRAL NOTES/SPECIFICATIONS. LENGTH SHALL NOT EXCEED 8'-0". PROVIDE SUPPORT PER SMACNA STANDARDS AND INSTALL FREE OF KINKS & SAGS. THERMAFLEX FLEXFLOW ELBOW SUPPORT (OR FLEXABOOT BY BUILD RIGHT PRODUCTS) ROUND SHEET-METAL DUCT DIAMETER AS INDICATED ON PLANS BRANCH DUCT CONICAL SPIN-IN FITTING WITH MVD CEILING -SEE ARCH. DWGS. FOR TYPE SUPPLY DIFFUSER OR REGISTER NOTES: 1. TAPES AND MASTICS USED TO SEAL FIBROUS GLASS DUCTWORK SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A AND SHALL BE MARKED “181 A-P”FOR PRESSURE-SENSITIVE TAPE, “181 A-M”FOR MASTIC OR “181 A-H”FOR HEAT-SENSITIVE TAPE. 2. TAPES AND MASTICS USED TO SEAL METALLIC AND FLEXIBLE AIR DUCTS SHALL COMPLY WITH UL 181B AND SHALL BE MARKED “181 B-FX”FOR PRESSURE-SENSITIVE TAPE OR “181 B-M”FOR MASTIC. 3. MECHANICAL FASTENERS FOR USE WITH FLEXIBLE NONMETALLIC AIR DUCTS SHALL COMPLY WITH UL 181B AND SHALL BE MARKED “181 B-C”. 4. ZIP TIES SHALL BE PLENUM RATED. INSTALL ZIP TIES USING A TENSIONING TOOL PER MANUFACTURER'S RECOMMENDATIONS. INTERIOR LINER PRE-INSULATED FLEXIBLE DUCTWORK. SEE GENERAL OTES/SPECIFICATIONS. PROVIDE SUPPORT PER SMACNA STANDARDS AND INSTALL FREE OF KINKS & SAGS TAB FITTING DIAMETER EQUAL TO FLEX DUCT RUN OUT SIZE BRANCH DUCT SUPPLY REGISTER (CEILING OR WALL) CEILING -SEE ARCH. DWGS. FOR TYPE TAB TYPE FITTING CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH NYLON ZIP TIES. APPLY A BEAD OF MASTIC BETWEEN THE INTERIOR LINER AND THE SHEET METAL PRIOR TO ZIP-TYING. THE INTERIOR LINER AND EXTERIOR INSULATION OF THE FLEX DUCT SHALL BE ZIP-TIED INDIVIDUALLY. INSTALL ZIP TIES USING A TENSIONING TOOL PER MANUFACTURER'S RECOMMENDATIONS NYLON ZIP TIES NOTES: 1. TAPES AND MASTICS USED TO SEAL FIBROUS GLASS DUCTWORK SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL 181A AND SHALL BE MARKED “181 A-P”FOR PRESSURE-SENSITIVE TAPE, “181 A-M”FOR MASTIC OR “181 A-H”FOR HEAT-SENSITIVE TAPE. 2. TAPES AND MASTICS USED TO SEAL METALLIC AND FLEXIBLE AIR DUCTS SHALL COMPLY WITH UL 181B AND SHALL BE MARKED “181 B-FX”FOR PRESSURE-SENSITIVE TAPE OR “181 B-M”FOR MASTIC. 3. MECHANICAL FASTENERS FOR USE WITH FLEXIBLE NONMETALLIC AIR DUCTS SHALL COMPLY WITH UL 181B AND SHALL BE MARKED “181 B-C”.45.0°INERTIA BASE 14" HIGH EQUIPMENT RAIL RPS STYLE ER-4B OR EQUAL BY PATE OR THYCURB. 1" DRAIN IN BOTTOM OF SCROLL DISCHARGEWEATHER PROOF MOTOR COMPARTMENT DUCT FULL SIZE OF FAN INLET MIN 40" DISCHARGE FRONT ELEVATION SIDE ELEVATION WELDED DUCT CONNECTION FULL RADIUS ELBOW (WHEN SPACE RESTRICTIONS PREVENT A RADIUS ELBOW, USE A MITERED RECTANGULAR ELBOW WITH 4 1/2" RADIUS DOUBLE THICKNESS TURNING VANES) TRANSITION AS REQUIRED DUCT THRU ROOF - SEE DETAIL 14" HIGH CURB (MIN.) SUPPORT DUCTWORK AT 6 FT. OC ON MIFAB MODEL DSAW SUPPORT SYSTEM ON WALKPAD MATERIAL ROUTE TO STAIR OR HOISTWAY WALL OR ROOF AS SHOWN 1/8" THICK NEOPRENE GASKET BETWEEN DUCTWORK & FAN, TYP. ANGLE IRON SUPPORT FRAME CONCRETE BASE (RE: STRUCT. DWGS.) DUCT MOUNTED SMOKE DETECTOR (RE: ELECT. DWGS.) CLASS 1 PARALLEL BLADE SMOKE DAMPER (NO -POWERED CLOSED/FAIL OPEN); RUSKIN MODEL SD60 45° WEATHER COWL WITH BIRDSCREEN RUBBER VIBRATION/ FRICTION PAD, TYP. AT EACH SUPPORT POINT SPF/EPF ACCESS DOOR FINISHED ROOF 2.5 x FAN DIAMETER MIN.36" MIN.MAINTAIN 20' MINIMUM FROM AIR EXHAUST SYSTEM OR OUTLET S NOTES: 1. EACH FAN SHALL BE PROVIDED WITH A DUCT SMOKE DETECTOR THAT SHALL ANNUNCIATE A SUPERVISORY SIGNAL ON THE FIREFIGHTER'S SMOKE CONTROL PANEL (FSCP) AND SHALL ILLUMINATE A LAMP ADJACENT TO THE FAN STATUS INDICATOR. A MANUAL OVERRIDE FOR EACH FAN SHALL ALSO BE PROVIDED. FANS SHALL NOT SHUT OFF UNTIL MANUALLY OVERRIDDEN BY FIRE DEPARTMENT PERSONNEL OR UNTIL THE FIRE ALARM SYSTEM IS RESET. THE FSCP SHALL ALSO INDICATE THAT AIR IS MOVING IN EACH STAIRWAY PRESSURIZATION SYSTEM. MONITORING OF AIR FLOW SHALL BE ACCOMPLISHED WITH DIFFERENTIAL PRESSURE ACROSS THE FAN.THE VFD SHALL NOT FAIL TO A GREATER CAPACITY THAN THAT ASSOCIATED WITH THE CONTROL SETPOINT FOR THE FAN. 2. FLEXIBLE DUCT CONNECTOR AT FAN DISCHARGE -FLEXIBLE DUCT CONNECTOR SHALL BE OZONE AND WEATHER RESISTANT; DURODYNE DUROLON OR EQUAL. 18 GAUGE ALUMINUM RAIN SHIELD -SEAL WEATHERTIGHT WITH 25 YEAR SILICONE SEALANT SEAL ALL JOINTS WEATHERTIGHT WITH 25 YEAR SILICONE SEALANT NOTE 2 STEEL ANGLE IRON BRACE STAIRWELL / ELELVATOR HOISTWAY FILL ANNULAR SPACE WITH EXPANDING FOAM INSULATION TO MAKE WEATHERTIGHT EXTERIOR WALL ALTERNATE THRU WALL PENETRATION NOTE: COORDINATE PENETRATION DETAIL WITH ARCH. DWGS. DUCT COLLAR FLOOR/CEILING ASSEMBLY SECURE FAN /DAMPER ASSEMBLY TO MOUNTING ANGLE PER UL INSTALLATION INSTRUCTIONS CEILING RADIATION DAMPER ONE HOUR FIRE RATED CEILING CEILING GRILLEPLASTER FLANGE MOUNTING BRACKET PER UL INSTALLATION INSTRUCTIONS FLEXIBLE DUCT CONNECTOR TRANSITION AS REQUIRED SEE FLOOR PLAN FOR DUCT SIZE CEILING EXHAUST FAN NOTES: 1. INSTALLATION SHALL BE IN STRICT COMPLIANCE WITH UL OR OTHER CERTIFICATION AGENCY'S INSTALLATION INSTRUCTIONS. SUBMIT INSTALLATION INSTRUCTION WITH SHOP DRAWINGS. 2. AT THE CONTRACTOR'S OPTION, THE CRD MAY BE SHIPPED LOOSE FOR FIELD INSTALLATION. 3. MOUNT THE CEILING GRILLE TO THE UNDER SIDE OF THE CRD USING THE HARDWARE FURNISHED WITH THE FAN. OPEN PARKING GARAGE PROPELLER FAN WITH MOTOR SIDE GUARD AND MOTORIZED DAMPER, TYP. ENCLOSED PARKING GARAGE ENCLOSED PARKING GARAGE VENTILATION SHAFT MOUNT FAN AS HIGH AS POSSIBLE, TYP. M M DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:35:51 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM05.03 ALS SDW 2247601 DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 12" = 1'-0" HORIZONTAL FIRE SECURITY DAMPER DETAIL1 Scale: 12" = 1'-0" BRANCH DUCT TAKE-OFF DETAIL2Scale: 12" = 1'-0" COMMERCIAL FLEXIBLE DUCT TAKE-OFF DETAIL3Scale: 12" = 1'-0" DWELLING UNIT FLEXIBLE DUCT TAKE-OFF DETAIL4 Scale: 6" = 1'-0" EXHAUST FAN (UTILITY SET) DETAIL5 Scale: NTS STAIR/ELEVATOR PRESSURIZATION FAN DETAIL6Scale: 12" = 1'-0" CEILING EXHAUST FAN WITH CRD DETAIL7 Scale: 12" = 1'-0" PARKING GARAGE VENTILATION SHAFT DETAIL8 NOTES: 1. DO NOT LOCATE FANS ABOVE DRIVE AISLES, WALK PATHS OR HANDICAP ACCESSIBLE AREAS. 2. FAN RUNS CONTINUOUSLY. AFTER FAN IS ENERGIZED, REMOVE THE PULL CORD FROM THE PULL CORD SWITCH. SECURE SAFETY CABLE MOUNT TO STRUCTURE ON 1/8" A36 STEEL PLATE WITH U RETAINER AND TWO (2) 1/4"x1-1/2" LAG SCREWS, LAG SHIELDS, AND TWO (2) 1/16" FLAT STEEL WASHERS SECURE FAN MOUNTING BRACKET TO STRUCTURE WITH 3/8" LAG SCREW, LAG SHIELD, AND TWO (2) 1/16" FLAT STEEL WASHERS CIRCULATION FAN ANGLE FAN SLIGHTLY DOWNWARD AND TIGHTEN FAN ANGLE ADJUSTMENT NUT PER MANUFACTURER'S INSTRUCTIONS SECONDARY SUPPORT CABLE FURNISHED WITH FAN -SECURE WITH CABLE CLAMPS AND TO STRUCTURE PER MANUFACTURER'S RECOMMENDATIONS GARAGE STRUCTURE (CEILING OR BEAM) - INSURE THAT FAN MOUNTING PROVIDES FOR MAXIMUM CLEAR HEIGHT AFF SURFACE MOUNTED RECEPTACLE (RE: ELECT. DWGS.) INTEGRAL POWER CORD AND PLUG -COIL AND SECURE EXCESS WITH CABLE TIE AND CONCRETE FASTENER EXHAUST AIR FLOW 1/2" X 1/2" WIRE MESH MOTORIZED DAMPER WALL HOUSING WALL (RE: ARCH. DWGS.) CLOSURE ANGLES PROPELLER FAN (RE:FAN SCHEDULE) MOTOR SIDE GUARD EXHAUST AIR FLOW MOTOR AND DRIVE ASSEMBLY ACCESSED FROM THIS SIDE STRUT CHANNEL AND HANGER RODS (MIN. OF 2 RODS) GARAGE EXHAUST SHAFT FAN/WALL HOUSING SUPPORT OPTIONS: 1. FROM STRUCTURE ABOVE WITH STRUT CHANNEL AND THREADED RODS. 2. FROM WALL BELOW FAN WITH ANGLE IRON "KICKERS". TRANSITION AS REQUIRED RE: PLANS FOR DUCT SIZE DUCT COLLAR SUSPEND FAN FROM STRUCTURE AS HIGH AS POSSIBLE WITH THREADED RODS (MINIMUM 4 ) (RE:STRUCTURAL DRAWINGS FOR ATTACHCHMENT DETAILS) NEOPRENE ISOLATOR AT HANGER BRACKET (TYP. OF 4) RE: PLANS FOR DUCT SIZE FLEXIBLE DUCT CONNECTOR ALTERNATE HANGER BRACKET LOCATION IN-LINE CENTRIFUGAL FAN FACTORY SUPPLIED INSULATED PLENUM LINEAR SUPPLY DIFFUSER - FRAME TO MATCH CEILING TYPE CEILING (RE:ARCH. DWGS. FOR TYPE) NOTE: 1. IF THE DIFFUSER IS INSTALLED IN AN INACCESSIBLE CEILING, DELETE INLET MVD AND PROVIDE A REMOTE CONTROLLED (OR FACE OPERATED) DAMPER ASSEMBLY. INLET MVD SUPPLY RUN OUT FLEX DUCT RUN-OUT FACE OR REMOTE CONTROLLED MVD (SUPPLY ONLY) FACTORY SUPPLIED INSULATED PLENUM LINEAR SLOT DIFFUSER -SEE PLANS AND GRILLES, REGISTERS AND DIFFUSER SCHEDULES FOR SIZE SUSPEND FROM STRUCTURE -REFER TO EXPOSED sPIRAL DUCT HANGER DETAIL SPIRAL DUCTWORK -ALL EXPOSED SHEET METAL SURFACES AND HANGER STRAPS SHALL HAVE A "PAINT GRIP" FINISH FOR FIELD PAINTING. AS AN OPTION, MILL PHOSPHATIZED STEEL DUCTWORK MAY BE USED. INTERNALLY INSULATE PER HVAC GENERAL NOTES OR SPEC SECTION 23 07 00 UNO FOLD SHEET METAL ENDS DOWN 1" SUPPLY REGISTER (RE: PLANS GRILLES, REGISTERS AND DIFFUSER SCHEDULE) TURN DOWN 30 DEGREES NOTES: 1. PAINT COLOR SHALL BE SELECTED BY THE ARCHITECT. 2. PAINTING BY OTHERS. COORDINATE WITH ARCHITECTURAL DWGS. EDH (RE: PLANS AND SCHEDULES) EDH SHALL BE LOCATED A MINIMUM OF 4' DOWNSTREAM OF AIR HANDLING EQUIPMENT, 2' FROM AN ELBOW (UPSTREAM OR DOWNSTREAM), 4' UPSTREAM OF A HUMIDIFIER, AND 4' UPSTREAM OR DOWNSTREAM FROM A TRANSITION NOTES: 1. MAINTAIN A MIN. OF 42" CLEARANCE (OR PER N.E.C.) IN FRONT OF ALL ELECTRIC DUCT HEATER CONTROL PANELS. THE WIDTH OF THE SERVICE CLEARANCE SHALL BE 30" OR THE WIDTH OF THE PANEL WHICHEVER IS GREATER. NO PIPES, SPRINKLERS, CONDUITS, ETC. SHALL BE INSTALLED WITHIN THIS ZONE. COORDINATE CAREFULLY WITH ALL OTHER TRADES. 2. WHERE EDHs OR THEIR WORKING CLEARANCE ARE LOCATED ABOVE LIGHT FIXTURES, THE FIXTURE SHALL HAVE A FLEXIBLE WHIP TO ALLOW TEMPORARY RELOCATION OF THE FIXTURE FOR ACCESS TO THE EDH. COORDINATE WITH THE ELECTRICAL CONTRACTOR. 3. INSTALL EDHs PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. FOR INSTALLATION IN DUCTBOARD, INSTALL PER THE LATEST EDITION OF SMACNA'S FIBROUS DUCT CONSTRUCTION STANDARDS. SEE NOTES BELOW C O N T R O L P A N E L A IR F L O W KINETICS NOISE CONTROL "KIP- R1" FIBERGLASS PAD CONTINUOUS BETWEEN RTU AND CURB PER MANUFACTURER'S RECOMMENDATIONS OUTDOOR AIR INTAKE HOOD FLEX DUCT CONNECTOR, TYP. ROOF DECK CONDENSATE DRAIN -TRAP PER DETAIL; SIZE AND ROUTE PER PLANS THERMOSTAT WIRING DUCT SMOKE DETECTOR PER CODE CONDENSER FAN DISCHARGE DISCONNECT SWITCH (SEE ELECTRICAL DWGS. UNLESS FACTORY MOUNTED) 14" HIGH (MIN). ROOF CURB FELTED SEMI-RIGID MINERAL WOOL BATT INSULATION, 4 LB. DENSITY, 8" THICK TOTAL LINE INSIDE OF CURB AND ROOF DECK WITH KINETICS KNM-100B ACOUSTICAL BARRIER POWER WIRING (RE: ELECT. DWGS.) NOTES: 1. WHEN FACTORY MOUNTED DISCONNECT SWITCH IS SCHEDULED OR SPECIFIED, CONDUIT FROM BELOW THE ROOF SHALL BE LOCATED INSIDE THE ROOF CURB. FIELD MOUNTED DISCONNECT SWITCH, BRACKETS, AND CONDUIT SHALL BE LOCATED SUCH THAT THEY ARE CLEAR OF ALL UNIT ACCESS PANELS AND DO NOT OBSTRUCT AIRFLOW. ATTACH DISCONNECT SWITCH SUPPORT BRACKETS TO STRUCTURAL MEMBERS OF UNIT AND NOT DIRECTLY TO SHEET-METAL CASING (COORDINATE WITH ELECTRICIAN). 2. DO NOT MOUNT DISCONNECT SWITCH OVER NAMEPLATE OF UNIT (COORDINATE WITH ELECTRICIAN). 3. CUT OPENINGS IN THE ROOF DECK ONLY FOR SUPPLY AND RETURN DUCT PENETRATIONS PER MANUFACTURER'S DIMENSIONAL LAYOUT DRAWINGS. BATT INSULATION SHALL COVER THE ENTIRE AREA OUTLINED BY THE CURB AND IN BETWEEN SUPPLY AND RETURN DUCTS. 4. MAINTAIN 10 LINEAL FEET BETWEEN OA INTAKE HOOD AND EXHAUST FANS, PLUMBING VENTS, ETC. WATERTIGHT REFRIGERANT LINE SET CHASE SUPPORT RS & RL 6' OC WITH MIFAB MODEL C PIPE SUPPORT ON ROOFING WALKPAD MATERIAL - SECURE PIPE WITH PIPE CLAMP INSULATED REFRIGERANT LINE SET, TYPICAL SECURE OUTDOOR UNIT TO WOOD SLEEPERS, TYP. 4 LOCATIONS CONDENSING UNIT OR HEAT PUMP 2"X2", 3/8" THICK NEOPRENE PAD, TYPICAL OF 4 SEAL OPENING AIR AND WATER TIGHT WITH EXPANDING FOAM INSULATION PRESSURE TREATED 4X4 WOOD SLEEPER-MOUNT ON ROOFING WALKPAD MATERIAL ROOF STRUCTURE NOTE: 1. MIFAB PIPE SUPPORT TO HAVE 14 GA. X 3/16" WIDE GALVANIZED CHANNEL. LENGTH TO SUIT QUANTITY OF PIPING SUPPORTED. PROVIDE INSULATION SHIELD WHERE STRUT CLAMP COMES IN CONTACT WITH INSULATION..H H = FAN INLET PRESSURE (IN. WC) + 1".H/2 MINIMUM SUSPENDED AHU UNION FACTORY DRAIN PAN HAND TIGHT PLUGS FOR CLEAN OUT PURPOSES FLOAT SWITCH WIRED TO SHUT DOWN RTU; SAF-T-SWITCH MODEL SS3 TRAP AND PIPE SAME SIZE AS UNIT CONNECTION -ROUTE TO NEAREST PLUMBING DRAIN FLOAT SWITCH WIRED TO SHUT DOWN AHU; SAF-T-SWITCH MODEL SS3 26 GA. SHEETMETAL DRAIN PAN -11/2" DEEP X 4" (MIN.) LARGER THAN THE AHU AND SHALL EXTEND BENEATH ALL PIPING CONNECTIONS TO THE AHU AND CONDENSATE TRAP NOTES: 1. SLOPE PIPING DOWN TOWARDS PLUMBING DRAIN AT 1/8" PER FOOT. 2. RUNNING TRAPS ARE NOT ALLOWED. 3. ALL PIPING LOCATED WITHIN A RETURN AIR PLENUM MUST MEET FLAME SPREAD/SMOKE DEVELOPED RATINGS OF 25/50. 4. TEST THE FLOAT SWITCH IN THE DRAIN PAN FOR PROPER OPERATION AT LEAST ONCE A YEAR. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:35:56 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM05.04 ALS SDW 2247601 DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 12" = 1'-0" GARAGE CIRCULATION FAN DETAIL1Scale: NTS GARAGE EXHAUST FAN (WALL MOUNTED PROPELLER) DETAIL2Scale: 12" = 1'-0" IN-LINE CENTRIFUGAL FAN DETAIL3Scale: 12" = 1'-0" LINEAR DIFFUSER DETAIL4 Scale: 6" = 1'-0" LINEAR SUPPLY/RETURN SLOT DETAIL5Scale: 12" = 1'-0" SPIRALDUCT SUPPLY REGISTER DETAIL6Scale: 12" = 1'-0" ELECTRIC DUCT HEATER DETAIL7Scale: 12" = 1'-0" ROOF TOP UNIT DETAIL8 Scale: 12" = 1'-0" OUTDOOR UNIT ROOF MOUNTING DETAIL9Scale: 12" = 1'-0" CONDENSATE DRAIN TRAP DETAIL10 ROUTE DRYER EXHAUST DUCT TO EXTERIOR WALL IN THE MOST DIRECT MANNER POSSIBLE 4"Ø DRYER EXHAUST DUCT SHALL BE A MINIMUM OF 26 GAUGE EXTEND 4"Ø DRYER EXHAUST DUCT THRU DRYER EXHAUST BOX TO ALLOW CONNECTION FOR FLEXIBLE DRYER HOSE DRYER EXHAUST WALL BOX -REFER TO PLANS FOR EXACT LOCATION AND SEE NOTES BELOW FOR ADDITIONAL INFORMATION METAL FLANGE SECURE EXHAUST BOX TO WALL PER MANUFACTURER'S RECOMMENDATIONS FLEXIBLE DRYER HOSE BY INSTALLER DRYER BY XXXXXX NOTES: 1. DRYER EXHAUST BOX MODEL 425 AS MANUFACTURED BY IN-O-VATE TECHNOLOGIES; LISTED FOR 1-HR (F AND T RATINGS) WALL INSTALLATION; UL THROUGH-PENETRATION FIRESTOP SYSTEM NO. W-L-7129. USE FOR UPWAR EXHAUST DIRECTION AND DOWNWARD EXHAUST DIRECTION ONLY FOR PEDESTAL AND STACKING DRYERS. 2. FOR DOWNWARD EXHAUST DIRECTION USE THE MODEL 4D (EXCEPT FOR PEDESTAL AND STACKABLE DRYERS). 3. INSTALLATION REQUIRES THE SPACES BETWEEN THE SIDES OF THE BOX AND THE STUDS AND THE SPACE IMMEDIATELY ABOVE THE BOX TO BE TIGHTLY PACKED WITH GLASS FIBER BATT OR MINERAL WOOL BATT INSULATION. REFER TO UL INSTALLATION DETAILS FOR ADDITIONAL INFORMATION. 4. INSTALL 16 GA STEEL SHIELD PLATES AT THE FINISHED FACE OF FRAMING MEMBERS WHERE THERE IS LESS THAN 11/4" BETWEEN THE DUCT AND THE FINISHED FACE OF THE FRAMING. SHIELD PLATES SHALL EXTEND 2" ABOVE SOLE PLATES AND 2" BELOW TOP PLATES. 5. PROVIDE DRYWALL BOX OUT WHEN THE DRYER VENT BOX IS LOCATED WITHIN A 1-HR RATED WALL ASSEMBLY. REFER TO MANUFACTURER'S AND UL INSTALLATION INSTRUCTIONS AND ARCHITECTURAL DETAILS. THE CLOTHES DRYER'S INSTALLED MAXIMUM EXHAUST LENGTH AS SHOWN IN THE INSTALLATION INSTRUCTIONS MUST EXCEED THE TOTAL SYSTEM EQUIVALENT LENGTH INDICATED BELOW DRYER CONNECTION MUST BE UL LISTED 4" ROUND FLEX DUCT TOTAL SYSTEM EQUIVALENT LENGTH = XX'-X" TOTAL STRAIGHT DUCT LENGTH = XX'-X" NUMBER OF 90° ELBOWS = # NUMBER OF 45° ELBOWS = # CONTRACTOR: INSERT THE ACTUAL FIELD MEASURED DISTANCE ACTUAL INSTALLED EQUIVALENT LENGTH FROM THE DRYER CONNECTION TO THE EXTERIOR VENT CAP NOTES: 1. PERMANENTLY AFFIX THE LABEL IN A CONSPICUOUS LOCATION WITHIN SIX (6) LINEAL FEET OF THE EXHAUST CONNECTION. 2. LABEL ABOVE IS SHOWN AS A GUIDELINE ONLY. ALTERNATE DESIGNS MAY BE SUBMITTED FOR REVIEW (SUCH AS THOSE MANUFACTURED BY IN-O-VATE TECHNOLOGIES, INC. -www.dryerplacard.com). 3. TOTAL STRAIGHT DUCT LENGTH SHALL BE MEASURED FROM FITTING TO FITTING (WITHOUT ELBOWS). 5/16" (MIN.) HIGH WHITE LETTERS RED PLASTIC BACKGROUND WITH ENGRAVED 1/8" (MIN.) HIGH WHITE LETTERS PRE-DRILLED HOLES 0' - 6"0' - 3"WARNING -RISK OF FIRE CONTRACTOR: INSERT THE ACTUAL NUMBER OF ELBOWS AMERICAN ALDES SPRING LOADED BACKDRAFT DAMPER -AIRFLOW DIRECTION SHALL BE MARKED ON THE OUTSIDE OF THE DAMPER PRIOR TO INSTALLATION TO VERIFY PROPER AIRFLOW DIRECTION. INSTALL SO THAT BDD CAN BE ACCESSED THRU WALL CAP HOOD (BDD CAN BE ELIMINATED IF A MOTORIZED DAMPER AT THE AIR HANDLER IS USED) HOODED WALL CAP WITH BIRD SCREEN -BROAN MODELS: 6"-641FA; 8"-643FA; 10"-610FA INSULATED OA DUCT -ROUTE TO AIR HANDLER (RE: FLOOR PLANS FOR SIZE AND ROUTING). SLOPE OUTERMOST 10' DOWN TOWARD WALL CAP NOTES: 1. WALL CAP CONNECTION AND BDD SIZE SHALL BE THE SAME SIZE AS THE OA DUCT. 2. WALL CAP SHALL BE ALUMINUM OR GALVANIZED STEEL WITH PAINT GRIP COATING FOR FIELD PAINTING (FIELD PAINTING BY OTHERS). 3. WALL CAP AND BDD SHALL BE ALUMINUM CONSTRUCTION FOR SEACOAST LOCATIONS. DRYER EXHAUST DUCT -ROUTE TO DRYER EXHAUST WALL BOX (RE: FLOOR PLANS FOR DUCT SIZE AND ROUTING). SLOPE OUTERMOST 10' DOWN TOWARD WALL CAP DETAIL NOTES: 1. WALL CAP SHALL BE FURNISHED WITH A DUCT COLLAR OF THE SAME SIZE AS THE EXHAUST DUCT. COLLAR SHALL BE SEALED AIRTIGHT TO THE WALL CAP. 2. MODEL NUMBER ABOVE IS ALUMINUM CONSTRUCTION. GALVANIZED STEEL MAY BE SUBSTITUTED. WALL CAP SHALL HAVE A PAINT GRIP COATING FOR FIELD PAINTING (FIELD PAINTING BY OTHERS). 3. WALL CAP AND BDD SHALL BE ALUMINUM CONSTRUCTION FOR SEACOAST LOCATIONS. (WITHIN 2 MILES OF A SEACOAST). WIDE MOUTH FULL SIZE HOODED WALL CAP WITH GASKETED SPRING RETURN BACKDRAFT DAMPER; ARTIS METALS MODEL WMSDWVA OR APPROVED EQUAL. THE DESIGN SHALL BE SUCH THAT THE CAP PROVIDES AN UNDIMINISHED PASSAGEWAY OF 12.5 SQUARE INCHES AS AN OPTION TO THE BROAN WALL CAP WITH SPRING LOADED BDD, PROVIDE AN AMERICAN ALDES SPRING LOADED BACKDRAFT DAMPER -AIRFLOW DIRECTION SHALL BE MARKED ON THE OUTSIDE OF THE DAMPER PRIOR TO INSTALLATION TO VERIFY PROPER AIRFLOW DIRECTION. INSTALL SO THAT BDD CAN BE ACCESSED THRU WALL CAP HOOD WALL CAP WITH GASKETED SPRING LOADED BACKDRAFT DAMPER AND BIRD SCREEN -3" OR 4" DUCT: BROAN MODEL 885; 6" DUCT: BROAN MODEL 641 OR APPROVED EQUAL ROUTE TO EXHAUST FAN (RE: FLOOR PLANS FOR SIZE AND ROUTING). SLOPE OUTERMOST 10' DOWN TOWARD WALL CAP DETAILS NOTES: 1. WALL CAP SHALL BE THE SAME SIZE AS THE EXHAUST DUCT -REFER TO FLOOR PLANS FOR SIZE. 2. WALL CAP SHALL BE ALUMINUM OR GALVANIZED STEEL WITH PAINT GRIP COATING FOR FIELD PAINTING (FIELD PAINTING BY THERS). 3. WALL CAP AND BDD SHALL BE ALUMINUM CONSTRUCTION FOR SEACOAST LOCATIONS. (WITHIN 2 MILES OF SEACOAST). EXIT SEAL SIZED BY MANUFACTURER PIPING MATERIALS AND SIZES PER PLAN AND SPECS FURNISH THE VALUT TO THE ROOFING INSTALLER AND COORDINATE THE INSTALLATION WITH ALL TRADES WIND RATE ALUMINUM COVER SECURED TO VAULT WITH VANDAL RESISTANT SCREWS PIPE PORTAL; THE VAULT MODEL AWIAS MANUFACTURED BY RPH, LLC INSULATED CURB EXTENSION INSULATED ALUMINUM CURB (18" HIGH MIN.) CURB FLANGE- SECURE TO ROOF DECK PER STRUCTURAL DWGS. EXIT SEAL SIZED BY MANUFACTURER PIPING MATERIALS AND SIZED PER PLANS AND SPECS RECOVERY BOARD FILL VOID BETWEEN PIPING AND CURB WITH FELTED SEMI-RIGID MINERAL WOOL BATT INSULATION, 4 LB. DENSITY SECURE PIPING TO CURBAND CHASE WALL INSULATED ALUMINIM CURB (18"HIGH MIN.) ROOFING SYSTEM/FLASHING ANGLE IRON FRAMING AROUND PERIMETER OF OPENING (RE: STRUCT. DWGS.) SECTION ISOMETRIC NOTES: 1. SIZE OF THE VAULT SHALL BE DETERMINED BY THE MANUFACTURER BASED ON THE SIZE AND QUANTITY OF PENETRATIONS. 2. THE VAULT SHALL BE INSULATED AND SEALED TO MEET SECTION C402 OF THE 2015 ICC INTERNATIONAL ENERGY CONSERVATION CODE. 3. THE VAULT SHALL BE THIRD PARTY WIND TESTED TO 225 MPH. 4. INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. EXIT SEALS SHALL BE ALUMINUM (STAINLESS STEEL FOR PROJECTS WITHIN 2 MILES OF THE SEACOAST). 20 GAUGE COUNTER- FLASHING WITH DRIP EDGE ALL AROUND HIGH DOMED CAPPED & GASKET FASTENERS AT 12" OC (MIN. 2 PER SIDE COMPOSITE ROOFING MATERIAL BY ROOFER PACK SPACE BETWEEN CURB AND DUCTWORK WITH MINERAL WOOL INSULATION -SEAL BOTH ENDS WITH MASTIC DUCTWORK -PAINT IN A COLOR SELECTED BY THE ARCHITECT CONTINUOUSLY WELD/ SOLDER FLASHING TO DUCTWORK 14" HIGH (MIN.) INSULATED ROOF CURB WITH FLASHING CANT & WOOD NAILER FINISHED ROOF 1 1/4" x 1 1/4" x 1/4" ANGLE IRON FRAME TO SUPPORT DUCTWORK (REFER TO STRUCTURAL DWGS NOTE: 1. FLASHING PER THE SMACNA ARCHITECTURAL SHEETMETAL MANUAL IS AN ACCEPTABLE ALTERNATIVE. SECURE ANGLE IRON TO STRUCTURE WITH 3/8" X 3" LONG LAG SCREWS OR EXPANSION BOLTS (RE: STRUCT. DWGS.)SECURE ANGLE TO DUCT WITH #8 X 3/4" LONG SELF-TAPPING SHEET METAL SCREWS AT 6" OC (MIN. 4 PER SIDE) PIPE -SEE PLANS AND RISER DIAGRAM FLOOR -RE: STRUCT. DWGS. RISER CLAMP BOLTS 2x2x2" HIGH NEOPRENE PADS AT RISER CLAMP BEARING POINTS PACK ANNULAR SPACE WITH FIBERGLASS OR MINERAL WOOL INSULATION SEAL TOP AND BOTTOM OF ANNULAR SPACE WITH A SEALANT THAT WILL BE WATERTIGHT AND REMAIN PLIABLE SCHEDULE 40 STEEL PIPE SLEEVE 1" ABOVE AND BELOW FINISHED FLOOR 1" SPACE-PACK WITH FIBROUS PACKING SEAL ALL AROUND WITH A SEALANT THAT WILL REMAIN PLIABLE16 GA SHEET- METAL SLEEVE MECHANICAL ROOM WALL CONSTRUCTED OF CMU SEAL ALL AROUND WITH A SEALANT THAT WILL REMAIN FLEXIBLE SEE PLANS FOR NUMBER AND SIZE OF PIPING DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:36:02 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM05.05 ALS SDW 2247601 DETAILS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 12" = 1'-0" DRYER EXHAUST WALL BOX DETAIL1Scale: 12" = 1'-0" DRYER EXHAUST VENT WARNING LABEL2Scale: 12" = 1'-0" OUTSIDE AIR INTAKE WALL CAP3Scale: 12" = 1'-0" DRYER EXHAUST WALL CAP DETAIL4 Scale: 12" = 1'-0" BATH AND/OR KITCHEN EXHAUST WALL CAP DETAIL5Scale: 3" = 1'-0" PIPE PORTAL/VAULT DETAIL7 Scale: 12" = 1'-0" DUCT THRU ROOF DETAIL6Scale: 12" = 1'-0" DETAIL OF PIPES AND CONDUITS PASSING THRU FLOORS8 Scale: 12" = 1'-0" DETAIL OF PIPES AND CONDUITS PASSING THRU WALLS9 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:36:10 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM06.01 ALS SDW 2247601 SCHEDULES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV EQUIPMENT SELECTIONS BASED ON PRODUCTS INDICATED. SUBJECT TO COMPLIANCE WITH ALL PRODUCTS, EQUAL PRODUCTS BY: CARRIER, TRANE, JOHNSON CONTROLS, LENNOX, DAIKIN, RHEEM.. 23. ECONOMIZER FAULT DETECTION AND DIAGNOSTICS (FDD) 22. CONDENSATE OVERFLOW PROTECTION VIA FLOAT SWITCH IN DRAIN PAN TO SHUT DOWN UNIT 21. MANUFACTURER STARTUP 20. CONDENSER COIL HAIL GUARDS UNLESS SPECIFIED WITH POWERED EXHAUST 19. INTEGRATED FIXED DRY BULB TYPE ECONOMIZER, SIZED FOR 100% SUPPLY AIR CAPACITY, CAPABLE OF SIMULTANEOUS ECONOMIZER AND COMPRESSOR OPERATION, WITH BAROMETRIC RELIEF, UNLESS SPECIFIED WITH POWERED EXHAUST 18. INTEGRATED DIFFERENTIAL ENTHALPY TYPE ECONOMIZER, SIZED FOR 100% SUPPLY AIR CAPACITY, CAPABLE OF SIMULTANEOUS ECONOMIZER AND COMPRESSOR OPERATION, WITH BAROMETRIC RELIEF, 17. FLEXIBLE POLYMER E-COAT FOR PROTECTION FROM SEA COAST ENVIRONMENT 16. ULTRAVIOLET GERMICIDAL LAMPS ON EVAPORATOR COIL AND DRAIN PAN 15. SUPPLY/RETURN DROP BOX 14. DIRECT DRIVE, PLENUM FAN 13. 2-STAGE COOLING AND 2 COMPRESSORS 12. RTU DEMAND CONTROL VENTILATION WIRING AND CONTROLS. PROVIDE WITH ONE WALL MOUNTED CO2 SENSOR AND ADDITIONAL SENSORS WHERE INDICATED. 11. PHASE MONITORING PROTECTION 10. GFCI 15 AMP CONVENIENCE OUTLET POWERED ON LINE SIDE OF DISCONNECT 9. KINETICS KNM-100B SOUND BARRIER MATERIAL INSIDE OF ROOF CURB AND ON TOP OF ROOF DECK 8. HOT GAS BYPASS. INSTALL ON LEADING COMPRESSOR ON 2-STAGE UNITS 7. SMOKE DETECTORS: MOUNT IN [SUPPLY] [RETURN] [SUPPLY & RETURN] AIRSTREAM FAN SPEED SHALL ADJUST TO MATCH COMPRESSOR OPERATION/STAGING. 6. UNIT MOUNTED FACTORY DISCONNECT SAV:STAGED AIR VOLUME FOR RTUS WITH 2-STAGE COOLING SHALL CONSIST OF MULTI-SPEED INDOOR FAN. 5. LOW AMBIENT OPERATION TO 20˚F 4. POWERED EXHAUST FOR ECONOMIZER RELIEF THERMOSTAT WITH FAN-ON-AUTO... 3. BAS COMPATIBLE (BACnet) CONTROLLER, PROGRAMABLE DIGITAL DISPLAY THERMOSTAT CV:CONSTANT VOLUME, VARIABLE TEMPERATURE. PROVIDE WITH 7-DAY PROGRAMMABLE AUTO CHANGEOVER 2. LOCKING THERMOSTAT COVER PROVIDE THE FOLLOWING FEATURES LISTED BELOW FOR THE SYSTEM TYPES IDENTIFIED FOR EACH RTU: 1. 7-DAY PROGRAMMABLE THERMOSTAT WITH FAN-ON-AUTO CONTROL AND AUTO HEATING/COOLING CHANGEOVER SYSTEM DESCRIPTION AND REQUIREMENTS: ACCESSORIES (THIS LIST IS NOT ALL INCLUSIVE. IN ADDITION, PROVIDE MANUFACTURER RECOMMEND ACCESSORIES FOR SAFE AND PROPER OPERATION): EQUIPMENT. THE EQUIPMENT NAMEPLATE SHALL BEAR A RATING OF NO LESS THAN THE PANELBOARD RATING OR THE CALCULATED FAULT CURRENT. CALCULATED AVAILABLE FAULT CURRENT INDICATED AT THE EQUIPMENT. THIS FAULT CURRENT VALUE SHALL BE UTILIZED TO DETERMINE THE CORRECT SHORT CIRCUIT CURRENT RATIN... H. COORDINATE WITH THE ELECTRICAL DRAWINGS FOR THE CALCULATED AVAILABLE FAULT CURRENT AT THE PANELBOARD SERVING MULTI-MOTOR AND COMBINATION-LOAD... G. VARIABLE FLOW FAN SYSTEMS SHALL BE PROVIDED WITH VARIABLE SPEED DRIVE AND AIR FLOW MEASURING DEVICE TO MONITOR AND CONTROL OUTSIDE AIR VOLUME. CONTROLS, ELECTRIC RESISTANCE HEATER, COMPRESSOR ANTI-RECYCLE CONTROLS, SINGLE POINT POWER CONNECTION, COOLING OPERATION DOWN TO 40˚F, 14" HIGH INSULATED ROOF CURB WITH BASE SLOPED TO MATCH ROOF PITCH. F. RTUS SHALL BE PROVIDED WITH 2" PLEATED DISPOSABLE FILTERS, CONDENSATE OVERFLOW SWITCH IN PRIMARY DRAIN PAN, MOTORIZED OUTSIDE AIR DAMPER, HP REVERSING VALVE, SUCTION LINE ACCUMULATOR, DEFROST CYCLE E. PROVIDE CRANKCASE HEATERS ON ALL UNITS 6 TONS AND LARGER. D. RETURN AND OUTSIDE AIR DAMPERS SHALL BE CLASS 1 LOW-LEAKAGE TYPE. C. ALL RTUS WITH CAPACITIIES 7.5 TONS AND HIGHER SHALL BE PROVIDED WITH MULTIPLE COMPRESSORS AND A MINIMUM OF 2 INDEPENDENT REFRIGERANT CIRCUITS. B. REFRIGERANT SHALL BE R-410A. A. SCHEDULED COOLING CAPACITY IS BASED ON THE FOLLOWING OUTDOOR AMBIENT TEMPERATURE: 95°F DB AND A PROJECT ELEVATION OF XXXX'. NOTES: (APPLIES TO ALL UNITS) RTU-LR-2 DAIKIN GPH CORRIDORS CV 1,950 295 295 1/2 2.0 6.0 71.0 50.4 78 64 11.1 13.0 70.0 17.0 2.3 -63 --8 675 RTU-LR-1 DAIKIN GPH CORRIDORS CV 1,950 295 295 1/2 2.0 6.0 71.0 50.4 78 64 11.1 13.0 70.0 17.0 2.3 -63 --8 675 RTU-HR-8 DAIKIN GPH CORRIDORS CV 3,395 510 510 2 2.0 10.0 113.0 84.0 78 64 11.1/12.6 -56.0 17.0 2.4 -63 --8 1,285 RTU-HR-7 DAIKIN GPH CORRIDORS CV 3,720 560 560 2 2.0 10.0 113.0 84.0 78 64 11.1/12.6 -56.0 17.0 2.4 -63 --8 1,285 RTU-HR-6 DAIKIN GPH CORRIDORS CV 2,100 320 320 1/2 2.0 6.0 71.0 50.4 78 64 11.1 13.0 70.0 17.0 2.3 -62 --8 675 RTU-HR-5 DAIKIN GPH CORRIDORS CV 2,050 310 310 1/2 2.0 6.0 71.0 50.4 78 64 11.1 13.0 70.0 17.0 2.3 -63 --8 675 RTU-HR-4 DAIKIN GPH CORRIDORS CV 2,300 345 345 1/2 2.0 6.0 71.0 50.4 78 64 11.1 13.0 70.0 17.0 2.3 -63 --8 675 - RTU-HR-3 DAIKIN GPH CORRIDORS CV 1,575 240 240 1/2 2.0 4.0 46.0 34.5 78 64 11.3 13.0 45.0 17.0 2.2 7.7 62 --8 610 - RTU-HR-2 DAIKIN GPH CORRIDORS CV 2,600 395 395 2 2.0 7.5 90.0 65.7 78 64 11.5 -52.0 17.0 2.4 -63 --8 1,135 - RTU-HR-1 DAIKIN GPH CORRIDORS CV 3,985 600 600 2 2.0 10.0 113.0 84.0 78 64 11.1/12.6 -56.0 17.0 2.4 -63 --8 1,285 - MIN MAX COP HSPFTOTALOUTSI...NOM TONS TOT SENS DB WB EER/IEER SEER CAP (MBH) OA AMB (˚F) EFFICI...KW No. STAGES AIRFLOW...MAX MOTOR HP ESP (IN WC) CAPACITY (MBH)EAT (˚F)EFFICIENCY INTEGRATED HP CAPACITY EAT (˚F) SUPP... MERV RATING TAG MANUF EQUIP SERIES AREA SERVED SYSTEM TYPE SUPPLY...NET COOLING HEATING FILTERS WEIGHT (LB)ACCESSORIES ROOFTOP UNITS (HEAT PUMPS) EQUAL PRODUCTS: PENNBARRY, CARNES, COOK, ACME, TWIN CITY, AEROVENT, DELTA BREEZ, AND PANASONIC PROVIDED THE PRODUCTS MEET OR EXCEEED THE SCHEDULED PERFORMANCE AND SPECIFICATIONS. UNLESS NOTED OTHERWISE, SELECTIONS ARE BASED ON PRODUCTS BY GREENHECK OR MANUFACTURER NOTED. 49. DISCONNECT SWITCH (FURNISHED AND INSTALLED BY ELECTRICAL) 25. INSULATED HOUSING 48. CEILING MOUNT KIT 24. COATING ON AIRSTREAM COMPONENTS FAN CONTROL, BACNET/MODBUS CONNECTIVITY, WEB INTEROPERABILITY. 23. NON-SPARKING CONSTRUCTION 47. JET VENT CONTROL CENTER WITH CO/NO2 SENSORS, FIRE ALARM INTERLOCK, SUPPLY/EXHAUST 22. EXPLOSION PROOF MOTOR 46. 6" LONG DUCT SECTION ON INLET AND OUTLET OF FAN WITH TEST PORTS FOR VERIFYING CFM 21. ACOUSTICAL CURB 45. MERV 13 FILTER 20. MOTOR COVER/BELT GUARD 44. MERV 6 FILTER 19. OUTLET GUARD 43. CORD AND PLUG 18. INLET GUARD 42. ALUMINUM DAMPER 17. ALUMINUM CONSTRUCTION 41. DISCONNECT SWITCH (FOR MOUNTING BY ELECTRICAL) 16. WALL MOUNTED SWITCH WITH HUMIDITY SENSOR (FOR MOUNTING BY ELECTRICAL) FAN" (FOR MOUNTING BY ELECTRICAL) 15. DYNAMICALLY RATED CEILING RADIATION DAMPER 40. WALL MOUNTED TIMER SWITCH (0-30 MINUTES) - LABEL "KITCHEN VENTILATION 14. VIBRATION ISOLATION KIT (NEOPRENE ISOLATORS)39. OVERHEAD MOUNTING KIT AND 9' CORD AND PLUG 13. ENERGY STAR 38. DOOR SWITCH (JAMB MOUNTED) 12. EC MOTOR 37. SEISMIC RATED CONSTRUCTION OPTION 11. VARIABLE FREQUENCY DRIVE (FOR MOUNTING BY ELECTRICAL)36. HIGH WIND RESISTANT CONSTRUCTION OPTION 10. SPEED CONTROLLER 35. EXTENDED GREASE LINES 9. SPEED CONTROLLER FOR BALANCING PURPOSES (FOR MOUNTING BY ELECTRICAL)34. REVERSIBLE AIRFLOW 8. INSECT SCREEN (1/4" X 1/4")33. LOUVER MOUNTING 7. BIRD SCREEN 32. OSHA MOTOR SIDE GUARD 6. MANUFACTURER'S STANDARD WALL CAP 31. MOTORIZED DAMPER WITH END SWITCH 5. MINIMUM 14" HIGH INSULATED ROOF CURB 30. 45 DEGREE WEATHERHOOD WITH BIRDSCREEN 4. COMBINATION STARTER/DISCONNECT (FOR MOUNTING BY ELECTRICAL)29. WALL COLLAR WITH CLOSURE ANGLES 3. FACTORY MOUNTED DISCONNECTING MEANS (CORD AND PLUG, SWITCH, ETC.)28. WALL HOUSING WITH CLOSURE ANGLES 2. MOTORIZED BACKDRAFT DAMPER 27. SPRING TYPE VIBRATION ISOLATORS 1. GRAVITY BACKDRAFT DAMPER 26. ANGLED FILTER BOX WITH 1" MERV 8 FILTERS ACCESSORIES: CS - OCCUPANCY SENSOR - REFER TO ELECTRICAL DWGS. CR - INTERLOCK WITH VENTILATION CONTROLLER/AIR HANDLER CQ - INTERLOCK WITH GAS MONITORING SYSTEM/BOILER CONTROLS ILM - IN-LINE MIXED FLOW CP - WALL MOUNTED TIMER (0-30 MINUTES LABELED "KITCHEN VENTILATION") FS - FILTERED SUPPLY CN - CONTINUOUS OPERATION ACF - AIR CURTAIN CM - INTERLOCK WITH ___________ CF - CIRCULATION FAN CL - WALL MOUNTED HUMIDITY SENSOR (DEWSTOP MODEL FS-300) UCF - UTILITY CENTRIFUGAL FAN CK - HYDROGEN GAS MONITORING AND CONTROL SYSTEM TA - TUBE AXIAL CJ - CO/NO2 GAS MONITORING AND CONTROL SYSTEM RUP - ROOF UPBLAST PROPELLER/AXIAL CH - VARIABLE FREQUENCY DRIVE WP - WALL PROPELLER CG - DOOR SWITCH (JAMB MOUNTED) ILC - IN-LINE CENTRIFUGAL CF - SWITCH ON FACE OF KITCHEN HOOD WC - WALL CENTRIFUGAL CE - INTERLOCK WITH MOTORIZED DAMPER/COMBINATION LOUVER RCU - ROOF CENTRIFUGAL UPBLAST CD - INTERLOCK WITH BAS/TIMECLOCK RCD - ROOF CENTRIFUGAL DOWNBLAST CC - START/STOP SWITCH WITH INDICATOR LIGHT CAB - IN LINE CABINET B - BELT CB - WALL MOUNTED THERMOSTAT CC - CEILING CENTRIFUGAL D - DIRECT CA - WALL SWITCH - REFER TO ELECTRICAL DWGS. FAN TYPES:DRIVE TYPE:FAN CONTROL NOTES: P. MAX. FREE-FIELD SOUND RATING AT 3 METERS SHALL NOT EXCEED 64 DBA. N. FANS AND ASSOCIATED COMPONENTS LOCATED IN RA PLENUMS SHALL BE PLENUM RATED. S&P REFRESH. M. APPROVED OAF SYSTEMS ARE APRILAIRE 8144NC/8120X; BROAN FIN-180P-HW; S&P TD-XS FAN WITH APRILAIRE 8120X/MD/FILTER AND FIELD CONTROLS FAPV WITH FAVC CONTROLLER AND FAD (FRESH AIR DAMPER), AND L. FANS WITH SELELCTABLE CFM SHALL BE SET TO THE APPROPRIATE SETTING DURING INSTALLATION PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. USED. REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. K. MOTORS CONTROLLED BY A VARIABLE FREQUENCY DRIVE (VFD) SHALL BE INVERTER DUTY MOTORS AND SHALL BE COMPATIBLE WITH THE PARTICULAR MANUFACTURER’S DRIVE THAT IS J. FANS SHALL BE CERTIFIED AND BEAR THE HVI-2100 OR AMCA LABEL FOR AIR AND SOUND PERFORMANCE. H. REFER TO AIR HANDLING UNIT SCHEDULE FOR OA CFM AND BALANCE ACCORDINGLY. CONTRACTOR AND PROVIDE RELAYS/CONTROLS AS REQUIRED. G. FANS THAT ARE INTERCONNECTED WITH LIGHTING CONTROLS (E.G. LIGHT SWITCH) MAY NOT BE THE SAME VOLTAGE AS THE LIGHTING CIRCUIT. COORDINATE WITH THE ELECTRICAL F. FANS THAT ARE SCHEDULED TO RUN CONTINUOUSLY SHALL HAVE IEC 60034-1 CONTINUOUS DUTY RATED MOTORS. E. WEIGHTS INCLUDE ACCESSORIES, CURBS, MOTORS, ETC. D. FOR FANS THAT ARE PART OF A SMOKE MANAGEMENT SYSTEM, REFER TO THE SMOKE CONTROL FAN SCHEDULE. C. REFER TO DETAILS FOR ADDITIONAL OPTIONS, ACCESSORIES, MOUNTING ARRANGEMENT, ETC. B. GREASE REMOVAL FANS SHALL BE LISTED FOR GREASE REMOVAL (UL 762) AND ELECTRICAL (UL 705) A. SELECTIONS ARE BASED ON A PROJECT ELEVATION OF XXXX'. CFM HAS BEEN CORRECTED FOR ALTITUDE. NOTES: TR-LR-1 GREENHECK USF UCF TRASH EXH 1850 2 CN NO 2, 14, 41 TR-HR-1 GREENHECK USF UCF TRASH EXH 820 2 CN NO 2, 14, 41 SPF-5 GREENHECK AX TA STAIR PRESSUIRZATION 10,000 2 YES SPF-4 GREENHECK AX TA STAIR PRESSUIRZATION 10,000 2 YES SPF-3 GREENHECK AX TA STAIR PRESSUIRZATION 10,000 2 YES SPF-2 GREENHECK AX TA STAIR PRESSUIRZATION 10,000 2 YES GSF-5-2 GREENHECK SBS WP GARAGE SUPPLY 2,600 0.5 CN NO 2, 28, 32, 41 GSF-5-1 GREENHECK SBS WP GARAGE SUPPLY 35,650 0.5 CJ NO 2, 4, 28, 32 GEF-5-2 GREENHECK SBE WP GARAGE EXH 2,600 0.5 CN NO 2, 28, 32, 41 GEF-5-1 GREENHECK SBE WP GARAGE EXH 35,650 0.5 CJ NO 2, 3, 11, 27 GSF-4-2 GREENHECK SBS WP GARAGE SUPPLY 2,600 0.5 CN NO 2, 28, 32, 41 GSF-4-1 GREENHECK SBS WP GARAGE SUPPLY 35,650 0.5 CJ NO 2, 4, 28, 32 GEF-4-2 GREENHECK SBE WP GARAGE EXH 2,600 0.5 CN NO 2, 28, 32, 41 GEF-4-1 GREENHECK SBE WP GARAGE EXH 35,650 0.5 CJ NO 2, 3, 11, 27 GSF-3-2 GREENHECK SBS WP GARAGE SUPPLY 2,600 0.5 CN NO 2, 28, 32, 41 GSF-3-1 GREENHECK SBS WP GARAGE SUPPLY 35,650 0.5 CJ NO 2, 4, 28, 32 GEF-3-2 GREENHECK SBE WP GARAGE EXH 2,600 0.5 CN NO 2, 28, 32, 41 GEF-3-1 GREENHECK SBE WP GARAGE EXH 35,650 0.5 CJ NO 2, 3, 11, 27 GSF-2-2 GREENHECK SBS WP GARAGE SUPPLY 2,600 0.5 CN NO 2, 28, 32, 41 GSF-2-1 GREENHECK SBS WP GARAGE SUPPLY 35,650 0.5 CJ NO 2, 4, 28, 32 GEF-2-2 GREENHECK SBE WP GARAGE EXH 2,600 0.5 CN NO 2, 28, 32, 41 GEF-2-1 GREENHECK SBE WP GARAGE EXH 35,650 0.5 CJ NO 2, 3, 11, 27 CF-#GREENHECK IC CF GARAGE CIRC 3,090 N/A 1/4 HP 1140 D N/A 140 CJ NO 3, 18, 19, 39 S&P TD-150 ILC COMMON AREA VENTILATION NOTE H 0.5 65 W N/A D 2.0 11 CN NO 2, 10, 41, 44 S&P TD-125 ILC COMMON AREA VENTILATION NOTE H 0.5 38 W N/A D 2.0 11 CN NO 2, 10, 41, 44 EF-A GREENHECK SP-AP CC DWELLING UNIT BATH EXH 50 0.5 14.3W 808 D 0.7 12 CA NO 1, 3, 9, 13, 15 TAG MANUF.MODEL TYPE DUTY CFM SP (IN WC) MAX. MOTOR SIZE RPM DRIVE MAX. SONES APPROX. WEIGHT (LBS)CONTROLLED BY EMERGENCY POWER ACCESSORIES/ REMARKS FANS EQUAL PRODUCTS BY CARRIER, MITSUBISHI, LG, JCI, TRANE, SAMSUNG, TOSHIBA, PANASONIC, SANYO, BOSCH SELECTIONS BASED ON PRODUCTS BY DAIKIN 9. HURRICANE RATED WALL MOUNTING KIT FOR OUTDOOR UNIT 4. REFRIGERANT LINE-SET (VERIFY LENGTH)8. SEACOAST PROTECTION PACKAGE 3. COMPRESSOR ANTI-RECYCLE CONTROLS 7. LOW AMBIENT WIND BAFFLE 2. CONDENSATE PUMP AND SAFETY SWITCH 6. METAL DRAIN PAN FOR OUTDOOR UNIT; DIVERSITECH OR APPROVED EQUAL 1. WIRED WALL MOUNT UNIT CONTROLLER 5. WALL MOUNTING KIT FOR OUTDOOR UNIT ACCESSORIES (THIS LIST IS NOT ALL INCLUSIVE. IN ADDITION, PROVIDE MANUFACTURER RECOMMEND ACCESSORIES FOR SAFE AND PROPER OPERATION): H. VERIFY MAXIMUM COMPRESSOR LIFT COMPATABILITY WITH MANUFACTURER AND OUTDOOR UNIT LOCATION. G. UNITS SHALL BE EQUIPPED WITH AN INTERNAL CONDENSATE TRAP OR CHECK VALVE. F. DISCONNECT SWITCH FOR OUTDOOR UNIT FURNISHED BY DIV 23, INSTALLED BY DIV 26. E. INDOOR AND OUTDOOR UNITS SHALL BE INSTALLED PER PLANS, MANUFACTURER'S RECOMMENDATIONS, AND LOCAL CODE REQUIREMENTS.W - WALL HUNG D. REFER TO HVAC GENERAL NOTES AND DETAILS FOR ADDITIONAL INFORMATION.C - CEILING CASSETTE C. SUBMIT AHRI CERTIFIED CAPACITIES FOR ACTUAL EQUIPMENT TO BE INSTALLED.FAN COIL UNIT TYPE: B. HEAT PUMP HEATING CAPACITY BASED ON AN INDOOR EAT OF 80°F DB/67°F WB AND XX°F ENTERING OUTDOOR UNIT.LEGEND A. COOLING CAPACITIES ARE BASED ON AN INDOOR EAT OF 80˚F DB/67˚F WB AND XXX˚F AMBIENT AND A PROJECT ELEVATION OF XXXX'. NOTES (APPLY TO ALL UNITS): DFH 1-2/DHP 1-2 FTX/RX MAIN TELECOM W 715 21.2 15.8 14.4 14.3 7.5 27 / 108 1,2,3,4,6 DFH 1-1/DHP 1-1 FTX/RX FIRE COMMAND CENTER W 715 21.2 15.8 14.4 14.3 7.5 27 / 108 1,2,3,4,6 TYPE TOTAL CFM TOTAL COOLING (MBH) SENSIBLE COOLING (MBH) HP HEAT (MBH) TAG SERIES FAN COIL UNIT/HEAT PUMP UNIT AREA SERVED FAN COIL CAPACITY MINIMUM SEER2 RATING MINIMUM HSPF2 RATING APPROX. WEIGHT (LBS) FCU/HP ACCESSORIES DUCTLESS SPLIT SYSTEM (HEAT PUMP) DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:36:18 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM06.02 ALS SDW 2247601 SCHEDULES SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV EQUAL PRODUCTS BY MARKEL, BERKO, QMARK, INDEECO, MARLEY, REDDI, STELPRO. SELECTIONS BASED ON PRODUCTS BY RAYWALL 10. COMPLETE INSTALLATION TO INCLUDE ALL SPLICES, END CAPS, MOUNTING HARDWARE, ETC. 9. FAN GUARD AND LOUVER DIFFUSER 8. CERTIFIED FOR ZERO CLEARANCE TO WALL OR CEILING 7. TEE BAR CEILING MOUNTING KIT 6. WALL MOUNTED THERMOSTAT 5. UNIVERSAL WALL/CEILING MOUNTING BRACKET 4. SEMI-RECESS MOUNTING KIT 3. SURFACE MOUNTING KIT 2. INTEGRAL DISCONNECT SWITCH 1. INTEGRAL TAMPERPROOF THERMOSTAT, UNLESS NOTED TO BE INTERLOCKED WITH FAN THERMOSTAT. ACCESSORIES: D. STAIRWELL AND SPRINKLER RISER ROOM HEATERS - THERMOSTAT SETPOINT SHALL BE 45°F. C. ALL HEATERS SHALL HAVE THERMAL OVERLOAD PROTECTION. B. OUTPUT CAPACITY SCHEDULED IS AT INSTALLED VOLTAGE. COORDINATE WITH ELECTRICAL... A. ALL HEATERS SHALL BE UL OR ETL TESTED AND LISTED. NOTES (APPLY TO ALL HEATERS): EUH-1-2 MUH UNIT HEATER TRASH RM 5.0 7'-6"27 1, 2, 5 EUH-1-1 MUH UNIT HEATER MAIN TRASH RM 15.0 7'-6"27 1, 2, 5 EUH-R-17 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-16 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-15 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-14 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-13 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-12 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-11 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-10 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-9 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-8 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-7 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-6 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-5 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-4 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-3 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-2 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EUH-R-1 MUH UNIT HEATER RETAIL 3.0 7'-6"27 1, 2, 5 EWH-5-1 AWH WALL HEATER STAIR 4 3.0 1'-0"25 1, 2, 5 EWH-2-1 AWH WALL HEATER STAIR 3 3.0 1'-0"25 1, 2, 5 EWH 1-3 AWH WALL HEATER STAIR 5 3.0 1'-0"25 1, 2, 5 EWH 1-2 AWH WALL HEATER STAIR 2 3.0 1'-0"25 1, 2, 5 EWH 1-1 AWH WALL HEATER STAIR 1 3.0 1'-0"25 1, 2, 5 TAG SERIES TYPE LOCATION OUTPUT CAPACITY (KW) MOUNTING HEIGHT AFF APPROX. WEIGHT (LBs) ACCESSORIES ELECTRIC HEATERS EQUAL PRODUCTS: KRUEGER, CARNES, ANEMOSTAT, TUTTLE & BAILEY, PRICE, METALAIRE, NAILOR. SELECTIONS ARE BASED ON PRODUCTS BY: TITUS. 5. INSECT SCREEN (1/16" SQUARE MESH) 4. RETURN HOOD/LIGHT SHIELD ON RA SLOTS 3. MANUFACTURER'S STANDARD INSULATED PLENUM 2. BALANCING DAMPER IN INLET 1. MOLDED INSULATION (R-6) BLANKET ON BACK PAN ACCESSORIES: J. REFER TO PLANS AND DETAILS FOR SOFFIT GRILLE SIZES AND TYPES. H. FOR DRYWALL OR PLASTER CEILING INSTALLATION, PROVIDE PLASTER FRAME. G. ONE 1" SLOT, 4' LONG TO MATCH LINEAR SUPPLY F. ONE 1" SLOT, 4' LONG TO MATCH LINEAR SUPPLY E. ONE 1" SLOT, 4' LONG, 10"Ø INLET, FACTORY INSULATED PLENUM. D. ONE 1" SLOT, 4' LONG, 10"Ø INLET, FACTORY INSULATED PLENUM.... BALANCING DAMPER SHALL BE INCLUDED. C. WHEN A DAMPER IS CALLED FOR ABOVE AND THE DEVICE IS TO BE MOUNTED IN AN INACCESSIBLE CEILING, EITHER A FACE ADJUSTABLE OR REMOTE CABLE OPERATED B. FINISH SHALL BE MANUFACTURER'S STANDARD. REFER TO ACCESSORIES/NOTES FOR CUSTOM FINISHES, IF ANY. SUBMIT COLOR CHART WITH SHOP DRAWINGS. COMPATIBLE WITH ADJACENT SURFACES AND FINISHES. A. REFER TO ARCHITECTURAL DRAWINGS FOR TYPE OF CEILING, SUSPENSION SYSTEM AND FINISHES WHERE DEVICE WILL BE MOUNTED. FRAME AND BORDER TYPE SHALL BE NOTES (APPLY TO ALL DEVICES UNO): HH 300FS SEE DWGS SUPPLY SEE DWGS SEE DWGS YES ALUMINUM DOUBLE DEFLECTION REGISTER 2 GG OMNI SEE DWGS RETURN SEE DWGS 24X24 YES STEEL SQUARE PLAQUE DIFFUSER FF OMNI SEE DWGS SUPPLY SEE DWGS 24X24 YES STEEL SQUARE PLAQUE DIFFUSER ACCESSORY 1 EE MLR SEE DWGS RETURN SEE DWGS SEE DWGS NO ALUMINUM LINEAR SLOT RETURN NOTE F DD ML-39 SEE DWGS SUPPLY SEE DWGS VARIES YES ALUMINUM LINEAR SLOT DUFFUSER NOTES C, E/ACCESSORY 3 CC 350FL SEE DWGS EXHAUST SEE DWGS SEE DWGS YES ALUMINUM 35° FIXED BLADE EXHAUST REGISTER BB 350RL SEE DWGS RETURN SEE DWGS SEE DWGS NO STEEL 35° FIXED BLADE RETURN GRILLE AA 300RS SEE DWGS SUPPLY SEE DWGS SEE DWGS YES STEEL DOUBLE DEFLECTION REGISTER TAG SERIES CFM DUTY NECK SIZE FACE SIZE DAMPER MATERIAL TYPE NOTES/ACCESSORIES GRILLE, REGISTERS & DIFFUSERS - COMMON AREAS EQUAL COMMERCIAL PRODUCTS TO TITUS: KRUEGER, CARNES, ANEMOSTAT, TUTTLE & BAILEY, PRICE, METALAIRE, NAILOR. EQUAL RESIDENTIAL PRODUCTS TO AIRMATE: HART & COOLEY, LIMA, TRUAIRE, USAIRE, SPEEDI-GRILLE, SHOEMAKER. 5. INSECT SCREEN (1/16" SQUARE MESH) 4. TOE DUCTOR UNDER CABINET TOE KICK SPACE DUCTING KIT 3. FINISH SHALL BE CUSTOM COLOR SELECTED BY THE ARCHITECT. SUBMIT COLOR CHART WITH SHOP DRAWINGS. 2. 1" MERV 6 FILTER 1. MOLDED INSULATION (R-6) BLANKET ON BACK PAN ACCESSORIES: F. SELECTIONS SHALL BE BASED ON A MAXIMUM PRESSURE DROP OF 0.05" INCLUDING THE... KITCHENS, UTILITY ROOMS - NC35; COMMON AREAS - NC35. E. SELECTIONS SHALL BE BASED ON THE FOLLOWING MAXIMUM NC LEVELS: DWELLING UNIT LIVING ROOMS AND BEDROOMS - NC30; BATHROOMS, D. REFER TO PLANS AND DETAILS FOR DWELLING UNIT SOFFIT GRILLE SIZES AND TYPES. C. STEEL CONSTRUCTION AS REQUIRED BY UL INSTALLATION DETAIL FOR GRILLE ACCESS TYPE FIRE/SMOKE DAMPER. B. FINISH SHALL BE MANUFACTURER'S STANDARD WHITE, UNLESS NOTED OTHERWISE. A. REFER TO ARCHITECTURAL DRAWINGS FOR TYPE OF CEILING AND/OR SUSPENSION SYSTEM. NOTES (APPLY TO ALL AIR DEVICES): E AIRMATE 240VO SEE DWGS SUPPLY SEE DWGS SEE DWGS YES ALUMINUM DOUBLE DEFELCTION SIDEWALL REGISTER D AIRMATE A170 N/A RETURN/TXR SEE DWGS SEE DWGS NO ALUMINUM STAMPED RETURN GRILLE 6 C AIRMATE 170 N/A RETURN/TXR SEE DWGS SEE DWGS NO STEEL STAMPED RETURN GRILLE 6 B AIRMATE A100 SEE DWGS SUPPLY SEE DWGS SEE DWGS YES ALUMINUM STAMPED SUPPLY REGISTER 6 A AIRMATE 100 SEE DWGS SUPPLY SEE DWGS SEE DWGS YES STEEL STAMPED SUPPLY REGISTER 6 TAG MFG SERIES BLOW DIRECTION DUTY NECK SIZE (INCHES)FACE SIZE DAMPER MATERIAL TYPE NOTES ACCESSORIES GRILLES, REGISTERS & DIFFUSERS - RESIDENTIAL OUTDOOR UNITS: GOODMAN, DAIKIN, CARRIER, BRYANT, TRANE, YORK, LENNOX, RHEEM. EQUAL PRODUCTS BY: INDOOR UNITS: GOODMAN, DAIKIN, FIRST COMPANY, SUNTHERM, ASPEN, CARRIER, BRYANT, TRANE, YORK, LENNOX, RHEEM, AIRMARK. SELECTIONS BASED ON PRODUCTS BY CARRIER. 21. 24V INTERFACE KIT 20. OUTDOOR TEMPERATURE SENSOR 19. METAL DRAIN PAN FOR OUTDOOR UNIT; DIVERSITECH OR APPROVED EQUAL 18. FILTER RACK WITH MERV 8 DURING CONSTRUCTION AND MERV 6 PRIOR TO PROJECT TURNOVER TO THE OWNER 17. COASTAL PROTECTION 16. LOW AMBIENT CONTROL TO 0˚F 15. PANCAKE UNIT - FULLY INSULATED ENCLOSURE 14. PANCAKE UNIT - HINGED AND GASKETED CEILING ACCESS PANEL FOR MAINTENANCE AND REMOVAL 13. WALL RECESSED UNIT WITH ACCESS PANEL/RETURN AIR GRILLE WITH 1" MERV 6 FILTER 12. FILTER RACK WITH 1" THICK DISPOSABLE MERV 6 FILTER 11. ANCHOR BRACKET KIT 10. SNOW STAND (18") 9. EVAPORATOR FREEZE PROTECTION KIT 8. CRANKCASE HEATER 7. HARD START KIT 6. SAF-T-SWITCH INSTALLED IN SECONDARY CONDENSATE DRAIN FOR OVERFLOW PROTECTION [OR ROUTE FULL SIZE OUTLET CONNECTION THRU CEILING WITH ESCUTCHEON] 5. BI-FLOW REFRIGERANT FILTER DRIER IF REQUIRED BY MANUFACTURER (LOCATE PER MANUFACTURER'S RECOMMENDATION) 4. FACTORY MOUNTED THERMAL EXPANSION VALVE TO ACHIEVE SEER RATING SCHEDULED (IF REQUIRED) 3. OUTDOOR UNIT - DISCONNECT FURNISHED BY MECHANICAL; INSTALLED BY ELECTRICAL (COORDINATE WITH ELECTRICAL SUBCONTRACTOR) 2. INDOOR UNIT - SINGLE POINT POWER WIRING KIT WITH DISCONNECTING MEANS AND OVERLOAD PROTECTION (COORDINATE WITH ELECTRICAL SUBCONTRACTOR) 1. IECC COMPLIANT 7-DAY PROGRAMMABLE THERMOSTAT; MANUAL CHANGEOVER WITH COMPRESSOR ANTI-RECYCLE PROTECTION, 2-STAGE HEATING, ADAPTIVE INTELLIGENT RECOVERY AND TIME DELAY RELAY ACCESSORIES (THIS LIST IS NOT ALL INCLUSIVE. IN ADDITION, PROVIDE MANUFACTURER RECOMMEND ACCESSORIES FOR SAFE AND PROPER OPERATION): S. IF THE OUTDOOR UNIT IS INSTALLED IN A LOCATION WHERE ICE MELT FROM THE DEFROST CYCLE MIGHT POSE A NUISANCE, PROVIDE A DRIP PAN WITH DRAIN LINE. SEE PLANS FOR ROUTING. MERV 6 FILTER BOX OR AN ALL-IN-ONE FRESH AIR VENTILATOR (APRILAIRE 8144NC OR APPROVED EQUAL) WITH CONTROLLER, MOTORIZED DAMPER, FILTER AND SPEED CONTROL. REFER TO DETAILS FOR ADDITIONAL REQUIREMENTS. R. OA CONTROLLED BY A VENTILATION CONTROLLER WITH TEMPERATURE/HUMIDITY LIMITS (APRILAIRE 8120X OR APPROVED EQUAL BY BROAN, FIELD CONTROLS OR S & P) AND AN OUTSIDE AIR FAN WITH MOTORIZED DAMPER, AND Q. FOR DWELLING UNITS THAT ARE NATURALLY VENTILATED, REFER TO ARCHITECTURAL DRAWINGS FOR CALCULATIONS. REQUIREMENTS. PROJECT IS DESIGNED AROUND 14.0 SEER AND 8.2 HSPF EQUIPMENT (APPLIES TO SINGLE-PHASE EQUIPMENT ONLY). P. DEPARTMENT OF ENERGY 2023 CHANGES REQUIRE THAT IF SPLIT SYSTEM HEAT PUMPS ARE MANUFACTUERED AFTER 01/01/2023 THE EFFICIENCY WILL HAVE TO MEET THE NEW 14.3 SEER2 AND 7.5 HSPF2 N. OBTAIN OUTSIDE AIR CFM FROM VENTILATION CALCULATIONS PROVIDED, BALANCE, AND DOCUMENT ACCORDINGLY. M. WALL HUNG AND CLOSET TYPE AIR HANDLERS SHALL HAVE INTEGRAL FILTER RACK/RAILS. THERMOSTAT AND OUTDOOR AIR TEMP SENSOR (IF REQUIRED). L. ELECTRIC HEAT SHALL OPERATE ONLY WHEN IN THE DEFROST MODE OR WHEN THE HEATING LOAD CANNOT BE MET BY THE COMPRESSOR ALONE. PROVIDE HP SHUT-OFF KIT AND OUTDOOR K. SEE DRAWINGS FOR AIR HANDLER ORIENTATION. PROVIDED FOR ALL SPLIT SYSTEMS WHERE THE OUTDOOR UNIT IS 20’ ABOVE OR BELOW THE INDOOR UNIT. LINE SET SIZE SHALL BE THE MAXIMUM RECOMMENDED BY THE MANUFACTURER TO MINIMIZE SYSTEM CAPACITY DE-RATING. J. FOR LONG LINE APPLICATIONS, PROVIDE ACCESSORIES AS RECOMMENDED BY THE MANUFACTURER. LONG LINE ACCESSORIES INCLUDING, BUT NOT LIMITED TO A TXV, SHALL BE H. PRIMARY CONDENSATE SHALL BE SIZED, TRAPPED AND ROUTED PER PLANS AND DETAILS. G. INDOOR AND OUTDOOR UNITS SHALL BE INSTALLED PER PLANS, MANUFACTURER'S RECOMMENDATIONS AND LOCAL CODE REQUIREMENTS. F. ECM ON EVAPORATOR FAN. ADJUST MOTOR SPEED TAP IN FIELD TO PROVIDE TOTAL CFM LISTED FOR EACH AIR... E. REFER TO HVAC GENERAL NOTES AND DETAILS FOR ADDITIONAL INFORMATION.H - HORIZONTAL D. ESP DOES NOT INCLUDE COIL, FILTER, CASING AND ACCESSORY LOSSES.W - WALL HUNG C. HEAT PUMP HEATING CAPACITY BASED ON AN INDOOR EAT OF 80°F DB/67°F WB AND 47°F/17°F ENTERING OUTDOOR UNIT.CP - CASED PANCAKE (LOW PROFILE)N - NATURAL BE INSTALLED.C - CLOSET M - MECHANICAL B. UNITS SHALL BE EQUIPPED WITH A THERMAL EXPANSION VALVE AS REQUIRED. SUBMIT AHRI CERTIFICATES FOR ACTUAL EQUIPMENT TO TYPE:OA SOURCE: A. COOLING CAPACITIES ARE BASED ON AN INDOOR EAT OF 80˚F DB/67˚F WB AND 95˚F AMBIENT.LEGEND SPECIFICATION NOTES (APPLY TO ALL UNITS): AH/HP-D FMA4X/GH5S036 W 1,195 M NOTE N 1/2 0.4 35.1 26.6 33.6/20.2 10.0 7.5 15.0 8.5 15.2 7.8 123/173 1, 2, 3, 4, 5, 6, 7, 8 AH/HP-C FMA4X/GH5S030 W 970 M NOTE N 1/2 0.4 28.5 21.8 28.4/17.2 8.0 6.0 15.0 9.0 15.2 8.1 123/171 1, 2, 3, 4, 5, 6, 7, 8 AH/HP-B FMA4X/GH5S024 W 790 M NOTE N 1/3 0.4 23.3 17.8 23.2/14.2 8.0 6.0 15.0 8.5 15.2 7.5 99/153 1, 2, 3, 4, 5, 6, 7, 8 AH/HP-A FMA4X/GH5S018 W 585 M NOTE N 1/3 0.4 17.5 13.2 17.3/10.3 5.0 3.8 15.5 8.5 15.2 7.8 99/135 1, 2, 3, 4, 5, 6, 7, 8 240V 208V SEER HSPF SEER2 HSPF2 TYPE TOTAL CFM OA SOURCE OA CFM MAX FAN HP ESP (IN WC) TOTAL COOLING (MBH) SENSIBLE COOLING (MBH) HEAT PUMP HEAT 47°F/17°F (MBH) SUPPLEMENTAL HEAT OUTPUT (kW) MANUFACTURED BEFORE 01/01/2023 (NOTE P) MANUFACTURED AFTER 01/01/2023 (NOTE P) TAG SERIES AIR HANDLER/ HEAT PUMP UNIT AIR HANDLER CAPACITY EFFICIENCIES (SINGLE-PHASE UNITS) APPROX. WEIGHT (AH/HP) (LBS) ACCESSORIES SPLIT SYSTEM HEAT PUMP UNITS - DWELLING UNITS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:36:24 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM07.01 ALS SDW 2247601 CALCULATIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV 3.UNIT SERVES ONLY ONE VENTILATION ZONE; Ev DOES NOT APPLY. 2.OUTSIDE AIR IS PRECONDITIONED AND SUPPLIED DIRECTLY TO THE SPACE AT ROOM TEMPERATURE WITH THE 150 FPM SUPPLY JET REACHING WITHIN 4'-6" OF THE FINISHED FLOOR. 1.UNIT OPERATES IN COOLING MODE ONLY OR SUPPLY AIR TEMPERATURE IS LESS THAN 15 DEG. F ABOVE THE SPACE TEMPERATURE. THE 150 FPM SUPPLY JET REACHES WITHIN 4'-6" OF THE FINISHED FLOOR. Notes: DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:2% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =320 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)315 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 10 Corridor Corridors 840 0.06 50.4 0 0 0 0 50.4 0.8 63 420 0.15 -3 Level 9 Corridor Corridors 840 0.06 50.4 0 0 0 0 50.4 0.8 63 420 0.15 -3 Level 8 Corridor Corridors 840 0.06 50.4 0 0 0 0 50.4 0.8 63 420 0.15 -3 Level 7 Corridor Corridors 840 0.06 50.4 0 0 0 0 50.4 0.8 63 420 0.15 -3 RTU-HR-6 Level 6 Corridor Corridors 840 0.06 50.4 0 0 0 0 50.4 0.8 63 420 0.15 -3 DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:1% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =310 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)306 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 10 Corridor Corridors 815 0.06 48.9 0 0 0 0 48.9 0.8 61 410 0.15 -3 Level 9 Corridor Corridors 815 0.06 48.9 0 0 0 0 48.9 0.8 61 410 0.15 -3 Level 8 Corridor Corridors 815 0.06 48.9 0 0 0 0 48.9 0.8 61 410 0.15 -3 Level 7 Corridor Corridors 815 0.06 48.9 0 0 0 0 48.9 0.8 61 410 0.15 -3 RTU-HR-5 Level 6 Corridor Corridors 815 0.06 48.9 0 0 0 0 48.9 0.8 61 410 0.15 -3 DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:1% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =345 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)343 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 10 Corridor Corridors 915 0.06 54.9 0 0 0 0 54.9 0.8 69 460 0.15 -3 Level 9 Corridor Corridors 915 0.06 54.9 0 0 0 0 54.9 0.8 69 460 0.15 -3 Level 8 Corridor Corridors 915 0.06 54.9 0 0 0 0 54.9 0.8 69 460 0.15 -3 Level 7 Corridor Corridors 915 0.06 54.9 0 0 0 0 54.9 0.8 69 460 0.15 -3 RTU-HR-4 Level 6 Corridor Corridors 915 0.06 54.9 0 0 0 0 54.9 0.8 69 460 0.15 -3 DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:2% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =240 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)236 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 10 Corridor Corridors 630 0.06 37.8 0 0 0 0 37.8 0.8 47 315 0.15 -3 Level 9 Corridor Corridors 630 0.06 37.8 0 0 0 0 37.8 0.8 47 315 0.15 -3 Level 8 Corridor Corridors 630 0.06 37.8 0 0 0 0 37.8 0.8 47 315 0.15 -3 Level 7 Corridor Corridors 630 0.06 37.8 0 0 0 0 37.8 0.8 47 315 0.15 -3 RTU-HR-3 Level 6 Corridor Corridors 630 0.06 37.8 0 0 0 0 37.8 0.8 47 315 0.15 -3 DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:1% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =395 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)390 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 10 Corridor Corridors 1040 0.06 62.4 0 0 0 0 62.4 0.8 78 520 0.15 -3 Level 9 Corridor Corridors 1040 0.06 62.4 0 0 0 0 62.4 0.8 78 520 0.15 -3 Level 8 Corridor Corridors 1040 0.06 62.4 0 0 0 0 62.4 0.8 78 520 0.15 -3 Level 7 Corridor Corridors 1040 0.06 62.4 0 0 0 0 62.4 0.8 78 520 0.15 -3 RTU-HR-2 Level 6 Corridor Corridors 1040 0.06 62.4 0 0 0 0 62.4 0.8 78 520 0.15 -3 DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:0% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =600 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)600 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 10 Corridor Corridors 1065 0.06 63.9 0 0 0 0 63.9 0.8 80 530 0.15 -3 Level 9 Corridor Corridors 1065 0.06 63.9 0 0 0 0 63.9 0.8 80 530 0.15 -3 Level 8 Corridor Corridors 1065 0.06 63.9 0 0 0 0 63.9 0.8 80 530 0.15 -3 Level 7 Corridor Corridors 1065 0.06 63.9 0 0 0 0 63.9 0.8 80 530 0.15 -3 Level 6 Corridor Corridors 1065 0.06 63.9 0 0 0 0 63.9 0.8 80 530 0.15 -3 Level 5 Corridor Corridors 890 0.06 53.4 0 0 0 0 53.4 0.8 67 445 0.15 -3 Level 4 Corridor Corridors 890 0.06 53.4 0 0 0 0 53.4 0.8 67 445 0.15 -3 RTU-HR-1 Level 3 Corridor Corridors 890 0.06 53.4 0 0 0 0 53.4 0.8 67 445 0.15 -3 (FT2)(CFM/FT2)(CFM)(PEOPLE)(CFM)(CFM)(CFM)(CFM) (PEOPLE / 1000 FT2) (CFM/ PERSON) 403.3.1.1 IMC 2018 403.3.1.1 403.3.1.1 Az DESCRIPTION OCCUPANCY CLASSIFICATION AREA,AREA OUTDOOR AIR RATE, Ra, PER TABLE AREA OUTDOOR AIR, RaAz OCCUPANT DENSITY PER TABLE NUMBER OF OCCUPANTS, Pz = Az * OCCUPANT DENSITY OCCUPANT OUTDOOR AIR RATE, Rp, PER TABLE OCCUPANT OUTDOOR AIR, RpPz BREATHING ZONE OUTDOOR AIR, Vbz = RpPz + RaAz ZONE AIR DISTRIBUTION EFFECTIVENESS, Ez, PER TABLE ZONE OUTDOOR AIR, Voz = Vbz/ Ez DESIGN SUPPLY AIR, Vpz ZONE OUTDOOR AIR FRACTION, Zpz = Voz/ Vpz ZONE VENTILATION EFFICIENCY, Evz = 1+Xs-Zpz NOTES VENTILATION AIR SCHEDULE - IMC 2018 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 12:36:30 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-M-r22_AustinS.rvtM07.02 ALS SDW 2247601 CALCULATIONS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCALS SDW Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV 3.UNIT SERVES ONLY ONE VENTILATION ZONE; Ev DOES NOT APPLY. 2.OUTSIDE AIR IS PRECONDITIONED AND SUPPLIED DIRECTLY TO THE SPACE AT ROOM TEMPERATURE WITH THE 150 FPM SUPPLY JET REACHING WITHIN 4'-6" OF THE FINISHED FLOOR. 1.UNIT OPERATES IN COOLING MODE ONLY OR SUPPLY AIR TEMPERATURE IS LESS THAN 15 DEG. F ABOVE THE SPACE TEMPERATURE. THE 150 FPM SUPPLY JET REACHES WITHIN 4'-6" OF THE FINISHED FLOOR. Notes: DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:2% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =295 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)290 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 8 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 Level 7 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 Level 6 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 Level 5 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 Level 4 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 RTU-LR-2 Level 3 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:2% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =295 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)290 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 8 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 Level 7 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 Level 6 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 Level 5 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 Level 4 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 RTU-LR-1 Level 3 Corridor Corridors 645 0.06 38.7 0 0 0 0 38.7 0.8 48 325 0.15 -3 DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:0% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =510 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)508 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 10 Corridor Corridors 830 0.06 49.8 0 0 0 0 49.8 0.8 62 415 0.15 -3 Level 9 Corridor Corridors 830 0.06 49.8 0 0 0 0 49.8 0.8 62 415 0.15 -3 Level 8 Corridor Corridors 830 0.06 49.8 0 0 0 0 49.8 0.8 62 415 0.15 -3 Level 7 Corridor Corridors 830 0.06 49.8 0 0 0 0 49.8 0.8 62 415 0.15 -3 Level 6 Corridor Corridors 830 0.06 49.8 0 0 0 0 49.8 0.8 62 415 0.15 -3 Level 5 Corridor Corridors 875 0.06 52.5 0 0 0 0 52.5 0.8 66 440 0.15 -3 Level 4 Corridor Corridors 875 0.06 52.5 0 0 0 0 52.5 0.8 66 440 0.15 -3 RTU-HR-8 Level 3 Corridor Corridors 875 0.06 52.5 0 0 0 0 52.5 0.8 66 440 0.15 -3 DESIGN EXCEEDS MINIMUM CODE REQUIREMENTS BY:1% DESIGN COMPLIES WITH CODE REQUIREMENTS:YES DESIGN OUTDOOR AIR =560 CFM OCCUPANT DIVERSITY (D=Ps/Total Pz) =1.00 TOTAL REQUIRED OUTDOOR AIR (Vot = Voz)555 CFM SYSTEM POPULATION (Ps) =0 People 3 Level 10 Corridor Corridors 955 0.06 57.3 0 0 0 0 57.3 0.8 72 480 0.15 -3 Level 9 Corridor Corridors 955 0.06 57.3 0 0 0 0 57.3 0.8 72 480 0.15 -3 Level 8 Corridor Corridors 955 0.06 57.3 0 0 0 0 57.3 0.8 72 480 0.15 -3 Level 7 Corridor Corridors 955 0.06 57.3 0 0 0 0 57.3 0.8 72 480 0.15 -3 Level 6 Corridor Corridors 955 0.06 57.3 0 0 0 0 57.3 0.8 72 480 0.15 -3 Level 5 Corridor Corridors 875 0.06 52.5 0 0 0 0 52.5 0.8 66 440 0.15 -3 Level 4 Corridor Corridors 875 0.06 52.5 0 0 0 0 52.5 0.8 66 440 0.15 -3 RTU-HR-7 Level 3 Corridor Corridors 875 0.06 52.5 0 0 0 0 52.5 0.8 66 440 0.15 -3 (FT2)(CFM/FT2)(CFM)(PEOPLE)(CFM)(CFM)(CFM)(CFM) (PEOPLE / 1000 FT2) (CFM/ PERSON) 403.3.1.1 IMC 2018 403.3.1.1 403.3.1.1 Az DESCRIPTION OCCUPANCY CLASSIFICATION AREA,AREA OUTDOOR AIR RATE, Ra, PER TABLE AREA OUTDOOR AIR, RaAz OCCUPANT DENSITY PER TABLE NUMBER OF OCCUPANTS, Pz = Az * OCCUPANT DENSITY OCCUPANT OUTDOOR AIR RATE, Rp, PER TABLE OCCUPANT OUTDOOR AIR, RpPz BREATHING ZONE OUTDOOR AIR, Vbz = RpPz + RaAz ZONE AIR DISTRIBUTION EFFECTIVENESS, Ez, PER TABLE ZONE OUTDOOR AIR, Voz = Vbz/ Ez DESIGN SUPPLY AIR, Vpz ZONE OUTDOOR AIR FRACTION, Zpz = Voz/ Vpz ZONE VENTILATION EFFICIENCY, Evz = 1+Xs-Zpz NOTES VENTILATION AIR SCHEDULE - IMC 2018 RS RI TV TV TV BSACACJ J J TC34KTOSDM XX-1 H S H S H H SS J H H COH COH SASA SASA CACA CACA AIMA WF VS CBXF A D3D3ARROWHEAD INDICATES HOMERUN. X-1,3,5 ADJACENT TO HOMERUN ARROWHEADS INDICATES HOMERUN TO PANEL X CIRCUIT NUMBERS 1, 3, AND 5. INDICATES CIRCUIT CONTINUATION OF CIRCUITS 3 AND 5 OF PANEL X. MARKS ACROSS RACEWAY SYMBOLS INDICATE THE NUMBER OF #12 CONDUCTORS (2 PHASE, 1 NEUTRAL) UNLESS OTHERWISE NOTED. NO MARKS INDICATES TWO #12 CONDUCTORS. EQUIPMENT GROUNDING CONDUCTORS ARE NOT INDICATED BY MARKS. RACEWAY/CABLE CONCEALED IN WALL AND/OR ABOVE CEILING RACEWAY CONCEALED BELOW GRADE OR IN-SLAB RACEWAY/CABLE CONCEALED IN WALL AND/OR ABOVE CEILING -EMERGENCY CIRCUIT RACEWAY INSTALLED EXPOSED GROUNDING CONNECTION (SYSTEM AND/OR EQUIPMENT) CONDUIT TURNING UP/DOWN CONDUIT STUB. TERMINATE IN INSULATED BUSHING OR CAP IF UNDERGROUND LIGHTING FIXTURE, 2X4, 1X4, 2X2 LIGHTING FIXTURE, 2X4, 1X4, 2X2 -PROVIDING EMERGENCY ILLUMINATION RECESSED LIGHTING FIXTURE. NORMAL AND EMERGENCY. STRIP FIXTURE -OVERHEAD/WALLMOUNTED DIRECTIONAL OR WALL WASH LIGHTING FIXTURE LIGHT TRACK AND LIGHT TRACK FIXTURES POLE MOUNTED LIGHT FIXTURE WITH ARM. SEE PLANS FOR NUMBER OF LUMINAIRES AND LIGHT DIRECTION. POST TOP OR BOLLARD LIGHT FIXTURE CEILING/PENDANT MOUNTED PADDLE FAN EXIT SIGN, CEILING/WALL MOUNTED. SHADED QUADRANT INDICATES FACE(S). PROVIDE ARROWS PER PLANS. L-1 L-2 L-3 L-4 L-5 L-6 X-1,3,5 3,5 SIZE 2/3R SIZE 2/3R 60/3/3R/40 60/3/3R 1P 1 POLE (2P, 3P, 4P, ETC.) A AMPERE AC ABOVE COUNTER OR AIR CONDITIONER ACLG ABOVE CEILING ADO AUTOMATIC DOOR OPENER AF AMP FRAME AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFI ARC FAULT CIRCUIT INTERRUPTER AHU AIR HANDLING UNIT AL ALUMINUM ALT ALTERNATE AMP AMPERE AMPL AMPLIFIER ANNUN ANNUNCIATOR APPROX APPROXIMATELY AQ-STATAQUASTAT ARCH ARCHITECT, ARCHITECTURAL AS AMP SWITCH AT AMP TRIP ATS AUTOMATIC TRANSFER SWITCH AUTO AUTOMATIC AUX AUXILIARY AV AUDIO VISUAL AWG AMERICAN WIRE GAUGE BATT BATTERY BD BOARD BLDG BUILDING BMS BUILDING MANAGEMENT SYSTEM C CONDUIT CAB CABINET CAT CATALOG CATV CABLE TELEVISION CB CIRCUIT BREAKER CCTV CLOSED CIRCUIT TELEVISION CKT CIRCUIT CLG CEILING COMB COMBINATION CMPR COMPRESSOR CONN CONNECTION CONST CONSTRUCTION CONT CONTINUATION OR CONTINUOUS CONTR CONTRACTOR CONV CONVECTOR CP CIRCULATING PUMP CRT CATHODE-RAY TUBE CT CURRENT TRANSFORMER CTR CENTER CU COPPER DCP DOMESTIC WATER CIRCULATING PUMP DEPT DEPARTMENT DET DETAIL DIA DIAMETER DISC DISCONNECT DIST DISTRIBUTION DN DOWN DPR DAMPER DS SAFETY DISCONNECT SWITCH DT DOUBLE THROW DWG DRAWING EC ELECTRICAL CONTRACTOR ELEC ELECTRIC, ELECTRICAL ELEV ELEVATOR EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM EMT ELECTRICAL METALLIC TUBING EP ELECTRIC PNEUMATIC EQUIP EQUIPMENT EWC ELECTRIC WATER COOLER EXIST EXISTING EXH EXHAUST EXP EXPLOSION PROOF FA FIRE ALARM FABP FIRE ALARM BOOSTER POWER SUPPLY PANEL FACP FIRE ALARM CONTROL PANEL FCU FAN COIL UNIT FIXT FIXTURE FLR FLOOR FLUOR FLUORESCENT FU FUSE FUDS FUSED SAFETY DISCONNECT SWITCH GA GAUGE GAL GALLON GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERATOR GFI GROUND FAULT CIRCUIT INTERRUPTER GFP GROUND FAULT PROTECTOR GND GROUND GRS GALVANIZED RIGID STEEL (CONDUIT) GYP BD GYPSUM BOARD HOA HANDS-OFF-AUTOMATIC SWITCH HORIZ HORIZONTAL HP HORSEPOWER HPF HIGH POWER FACTOR HT HEIGHT HTG HEATING HTR HEATER HV HIGH VOLTAGE HVAC HEATING, VENTILATING AND AIR CONDITIONING HWP HYDRONIC WATER PUMP IC INTERRUPTING CAPACITY IG ISOLATED GROUND IMC INTERMEDIATE METAL CONDUIT INCAND INCANDESCENT IR INFRARED I/W INTERLOCK WITH J-BOX JUNCTION BOX KV KILOVOLT KVA KILOVOLT-AMPERE KVAR KILOVOLT-AMPERE REACTIVE KW KILOWATT KWH KILOWATT HOUR LOC LOCATE OR LOCATION LT LIGHT LTG LIGHTING LTNG LIGHTNING LV LOW VOLTAGE MAX MAXIMUM MAG.S MAGNETIC STARTER M/C MOMENTARY CONTACT MC MECHANICAL CONTRACTOR MCB MAIN CIRCUIT BREAKER MCC MOTOR CONTROL CENTER MDC MAIN DISTRIBUTION CENTER MDP MAIN DISTRIBUTION PANEL MFR MANUFACTURER MFS MAIN FUSED DISCONNECT SWITCH MH MANHOLE MIC MICROPHONE MIN MINIMUM MISC MISCELLANEOUS MLO MAIN LUGS ONLY MMS MANUAL MOTOR STARTER MOA MULTIOUTLET ASSEMBLY MSP MOTOR STARTER PANELBOARD MSBD MAIN SWITCHBOARD MT MOUNT MT.C EMPTY CONDUIT MTS MANUAL TRANSFER SWITCH MTR MOTOR, MOTORIZED N.C. NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION NFDS NON-FUSED SAFETY DISCONNECT SWITCH NIC NOT IN CONTRACT NL NIGHT LIGHT N.O. NORMALLY OPEN NPF NORMAL POWER FACTOR NTS NOT TO SCALE OH OVERHEAD OL OVERLOADS PA PUBLIC ADDRESS PB PULL BOX OR PUSHBUTTON PE PNEUMATIC ELECTRIC PED PEDESTAL PF POWER FACTOR PH PHASE PIV POST INDICATING VALVE PNL PANEL PP POWER POLE PR PAIR PRI PRIMARY PROJ PROJECTION PRV POWER ROOF VENTILATOR PT POTENTIAL TRANSFORMER PVC POLYVINYL CHLORIDE (CONDUIT) PWR POWER QUAN QUANTITY RCPT RECEPTACLE REQD REQUIRED RM ROOM RSC RIGID STEEL CONDUIT RTU ROOF TOP UNIT SC SURFACE CONDUIT SEC SECONDARY SHT SHEET SIM SIMILAR S/N SOLID NEUTRAL SPEC SPECIFICATION SPKR SPEAKER SP SPARE SR SURFACE RACEWAY SS STAINLESS STEEL SSW SELECTOR SWITCH S/S STOP/START PUSHBUTTONS STA STATION STD STANDARD SURF SURFACE MOUNTED SW SWITCH SWBD SWITCHBOARD SYM SYMMETRICAL SYS SYSTEM TEL TELEPHONE TEL/DATA TELEPHONE/DATA TERM TERMINAL TL TWIST LOCK TR TAMPER RESISTANT T-STAT THERMOSTAT TTC TELEPHONE TERMINAL CABINET TV TELEVISION TVTC TELEVISION TERMINAL CABINET TYP TYPICAL UC UNDER COUNTER UE UNDERGROUND ELECTRICAL UG UNDERGROUND UH UNIT HEATER UT UNDERGROUND TELEPHONE UTIL UTILITY UV UNIT VENTILATOR OR ULTRAVIOLET V VOLT VA VOLT-AMPERES VDT VIDEO DISPLAY TERMINAL VERT VERTICAL VFD VARIABLE FREQUENCY DRIVE VOL VOLUME W WATT W/ WITH WG WIRE GUARD WH WATER HEATER W/O WITHOUT WP WEATHERPROOF XFMR TRANSFORMER XFR TRANSFER ∠ANGLE @ AT ▲DELTA 'FEET "INCHES #NUMBER Ø PHASE C CENTER LINE P PLATE ABBREVIATIONS ELECTRICAL SYMBOLS SINGLE RECEPTACLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE CEILING MOUNTED DESCRIPTIONSYMBOLNOTE L-1 HEIGHT 18" 18" DUPLEX RECEPTACLE ABOVE COUNTER43" 18" DUPLEX RECEPTACLE GFCI ABOVE COUNTER43" DUPLEX RECEPTACLE GFCI DUPLEX RECEPTACLE ABOVE COUNTER WITH (2) DC USB CHARGING PORTS 18" 43" 18" 43" ISOLATED GROUND DUPLEX RECEPTACLE43" 18" SPECIAL PURPOSE RECEPTACLE OUTLET, NEMA CONFIGURATION TO MATCH PLUG SPLIT WIRED DUPLEX RECEPTACLE. ONE RECEPTACLE SHALL BE CONTROLLED WHERE USED TO CONSERVE ENERGY, RECEPTACLE SHALL BE SUITABLY MARKED PER NEC REQUIREMENTS. DUPLEX RECEPTACLE WITH (2) DC USB CHARGING PORTS DUPLEX GF PROTECTED RECEPTACLE ABOVE COUNTER WITH (2) DC USB CHARGING PORTS DUPLEX GF PROTECTED RECEPTACLE WITH (2) DC USB CHARGING PORTS L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 L-1 CLOCK (WALL RECESSED) JUNCTION BOX JUNCTION BOX FLOOR MOUNTED JUNCTION BOX CEILING MOUNTED L-1 DUPLEX RECEPTACLE FLOOR MOUNTED QUAD RECEPTACLE CEILING MOUNTED QUAD RECEPTACLE FLOOR MOUNTED 18" FIRE-RATED POKE-THRU DEVICE MULTI-OUTLET ASSEMBLY WITH OUTLETS ON CENTERS AS INDICATED IN NOTES OR SPECIFICATIONS. MOUNT 6" ABOVE COUNTER OR AS INDICATED CIRCUITING/CONDUIT SURFACE MOUNTED LIGHTING FIXTURE. NORMAL AND EMERGENCY. WALL MOUNTED LIGHTING FIXTURE. NORMAL AND EMERGENCY. PANELBOARD -WALL MOUNTED (SURFACE) PANELBOARD -WALL MOUNTED (RECESSED) EMERGENCY LIGHTING FIXTURE LIGHTING CONTACTOR / TIMECLOCK SINGLE POLE SINGLE THROW TOGGLE SWITCHL-1 46" 3-WAY TOGGLE SWITCHL-1 46" 4-WAY TOGGLE SWITCHL-1 46" MOTOR RATED SWITCHL-1 46" KEYED SWITCHL-1 46" TIMER SWITCHL-1 46" OCCUPANCY SWITCHL-1 46" DIMMER SWITCHL-1 46" NONFUSIBLE DISCONNECT SWITCH, RATING/POLES/NEMA ENCLOSURE FUSIBLE DISCONNECT SWITCH, RATING/POLES/NEMA ENCLOSURE/FUSE RATING MAGNETIC MOTOR STARTER. NEMA SIZE RATING/ENCLOSURE (NEMA 1 IF NOT SHOWN) COMBINATION MAGNETIC MOTOR STARTER AND DISCONNECT MEANS, NEMA SIZE RATING/ENCLOSURE (NEMA 1 IF NOT SHOWN) CURRENT TRANSFORMER CABINET POWER METER AND SOCKET MOTOR FIRE ALARM HORN WITH VISUAL DEVICE, WALL/CEILING MOUNTED. NUMERAL INDICATES CANDELA RATING. L-3, L-5 15cd FIRE ALARM SPEAKER WITH VISUAL DEVICE, WALL/CEILING MOUNTED. NUMERAL INDICATES CANDELA RATING.15cd L-3, L-5 FIRE ALARM HORN, WALL/CEILING MOUNTED.L-3, L-5 FIRE ALARM SPEAKER, WALL/CEILING MOUNTED.L-3, L-5 FIRE ALARM MANUAL PULL STATION FIRE ALARM VISUAL DEVICE, WALL/CEILING MOUNTED. NUMERAL INDICATES CANDELA RATING. L-3 15cd FIREMAN PHONE FIREMAN PHONE JACK 42" 42" FIRE ALARM SMOKE DETECTOR, WALL/CEILING MOUNTED L-4 FIRE ALARM SMOKE DETECTOR WITH INTEGRAL HORN, WALL/CEILING MOUNTED FIRE ALARM SMOKE/CO DETECTOR WITH INTEGRAL HORN, WALL/CEILING MOUNTED 120V AUDIBLE SMOKE ALARM WITH BATTERY, WALL/CEILING MOUNTED L-4, L-5 L-4, L-5 L-4, L-6 120V AUDIBLE/VISUAL SMOKE ALARM WITH BATTERY, WALL/CEILING MOUNTED. NUMERAL INDICATES CANDELA L-4, L-6 15cd 120V AUDIBLE COMBINATION SMOKE/CO ALARM, WALL/CEILING MOUNTED. NUMERAL INDICATES CANDELA 120V AUDIBLE/VISUAL COMBINATION SMOKE/CO ALARM, WALL/CEILING MOUNTED. NUMERAL INDICATES CANDELA15cd L-4, L-6 L-4, L-6 ADDRESSABLE INTELLIGENT MODULE -FIRE ALARM SYSTEM FIRE ALARM HEAT DETECTOR, WALL/CEILING MOUNTED. FIRE ALARM ANALOG HEAT DETECTOR, WALL/CEILING MOUNTED. CONNECTION TO FIRE PROTECTION SYSTEM WATER FLOW VALVE SUPERVISORY FIRE ALARM DOOR HOLDER FIRE ALARM DOOR CLOSER DUCT MOUNTED SMOKE DETECTOR REMOTE TEST STATION REMOTE INDICATOR LIGHT FIRE ALARM CONTROL PANEL, SURFACE FIRE ALARM CONTROL PANEL, RECESSED FIRE ALARM ANNUNCIATOR PANEL, RECESSED TELEPHONE OUTLET, WALL MOUNTED. TELEPHONE OUTLET, ABOVE COUNTER TELEPHONE OUTLET, FLOOR MOUNTED TELEPHONE OUTLET, CEILING MOUNTED L-1, L-2 18" 43" COMBINATION TELEPHONE/DATA OUTLET, WALL MOUNTED. COMBINATION TELEPHONE/DATA OUTLET, ABOVE COUNTER COMBINATION TELEPHONE/DATA OUTLET, FLOOR MOUNTED COMBINATION TELEPHONE/DATA OUTLET, CEILING MOUNTED L-1, L-2 18" 43" DATA OUTLET, WALL MOUNTED. DATA OUTLET, ABOVE COUNTER DATA OUTLET, FLOOR MOUNTED DATA OUTLET, CEILING MOUNTED L-1, L-2 18" 43" TELEVISION OUTLET, WALL MOUNTED. TELEVISION OUTLET, FLOOR MOUNTED TELEVISION OUTLET, CEILING MOUNTED 18"L-1 TWO-WAY COMMUNICATION BASE STATION46" CALL BOX46" DESCRIPTIONSYMBOLNOTEHEIGHT LEGEND NOTES MOUNTING HEIGHTS NOTED ARE TO THE CENTER OF DEVICE ABOVE FINISHED FLOOR, UNLESS NOTED OTHERWISE. STUB 3/4" CONDUIT 6" ABOVE ACCESSIBLE CEILING AND TERMINATE WITH NYLON GROMMET. WHERE FIRE ALARM VISUAL DEVICES ARE WALL-MOUNTED, THE ENTIRE LENS SHALL BE MOUNTED A MINIMUM OF 80" AFF AND NOT GREATER THAN 96" AFF. TOPS OF WALL- MOUNTED AUDIBLE-ONLY DEVICES SHALL NOT BE LESS THAN 90" AFF AND NOT LESS THAN 6" BELOW FINISHED CEILING. WITHIN SLEEPING AREAS, WHERE DISTANCE FROM CEILING TO TOP OF VISUAL DEVICE LENS IS LESS THAN 24", DEVICE SHALL HAVE INTENSITY OF 177 CANDELA. 120V SMOKE AND CO ALARMS SHALL HAVE BATTERY BACKUP AND BE PROVIDED WITH AUXILIARY CONTACTS. WALL MOUNTED DEVICE SHALL BE LOCATED 4" MIN. AND 12" MAX. FROM CEILING. AUDIBLE SIGNAL OF FIRE ALARM DEVICES LOCATED IN SLEEPING ROOMS SHALL BE 520HZ. AUDIBLE SIGNAL OF SMOKE AND CO ALARMS LOCATED IN SLEEPING ROOMS AND DWELLINGS DESIGNATED FOR H/C ACCESSIBILITY OR HEARING IMPAIRED SHALL BE 520HZ. VOLTAGE (H = 480V, L= 208V) *SERVICE TYPE (MAIN SERVICE "A", "B", "1", ETC.) E H A 2 A BUILDING, LEVEL, OR ZONE/AREA ("1", "2", "A", ETC.) PANELBOARD IDENTIFICATION *PREFIXES (E = EMERGENCY, S = STANDBY, O = OPTIONAL) *ITERATIVE SEQUENCE LETTER ("A", "B", "C", ETC.) * DENOTES ONLY USED IF APPLICABLE EXAMPLES: HA1A (480V PANEL, SERVED FROM MSA, MECHANICAL LOADS, (NO BUILDING, LEVEL, OR ZONE), FIRST PANEL) LB2C (208V PANEL, SERVED FROM MSB, METERING LOAD TYPE NOT APPLICABLE, LEVEL 2, THIRD PANEL) A.PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS MUST BE FIRESTOPPED WITH AN APPROVED MATERIAL. 1.CONDUITS MAY PENETRATE WALLS OR PARTITIONS, PROVIDED THEY ARE FIRE-STOPPED. 2.OPENINGS FOR STEEL ELECTRICAL BOXES NOT EXCEEDING 16 SQUARE INCHES ARE PERMITTED PROVIDED OPENINGS DO NOT AGGREGATE MORE THAN 100 SQUARE INCHES FOR ANY 100 SQUARE FEET OF WALL OR PARTITION. 3.OUTLET BOXES ON OPPOSITE SIDES OF WALLS OR PARTITIONS MUST BE SEPARATED BY A HORIZONTAL DISTANCE OF 24 INCHES. B.LIGHT FIXTURES AND OTHER APPARATUS SUPPORTED BY THE ACOUSTICAL CEILING GRID MUST MEET THE REQUIREMENTS OF NEC SECTION 410.16, MEANS OF SUPPORT. C.RECESSED LIGHTING FIXTURES INSTALLED IN FIRE RATED CEILING ASSEMBLIES SHALL BE FIRE RATED FIXTURES BEARING THE UL FIRE RATED LABEL. FIXTURES SHALL BE INSTALLED IN ACCORDANCE WITH THE UL FIRE RESISTANCE DIRECTORY, AND SHALL INCLUDE A FIRE RATED ENCLOSURE INSTALLED OVER THE FIXTURE THAT MEETS THE REQUIREMENTS OF THE UL FIRE RESISTANCE DIRECTORY. SPECIFIC CODE NOTES FIRE PROTECTION REQUIREMENTS QUADRAPLEX RECEPTACLE18"L-1 3-WAY DIMMER SWITCHL-1 46" OCCUPANCY DIMMER SWITCHL-1 46" DISTRIBUTION PANELBOARD -WALL MOUNTED (SURFACE) S M SMOKE DAMPER MOTORIZED DAMPER DUCT SMOKE DETECTOR COMBINATION FIRE/SMOKE DAMPERC DAMPER TAGS G1 G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G14 G15 PROJECT DESIGN IS BASED UPON THE 2020 EDITION OF THE NATIONAL ELECTRICAL CODE. WHEN CONDUCTOR OR CONDUIT SIZE IS INDICATED FOR BRANCH CIRCUIT HOMERUN, THE CONDUCTOR AND CONDUIT SIZE INDICATED SHALL BE USED FOR THE COMPLETE CIRCUIT. REFER TO THE APPROPRIATE DRAWINGS (INCLUDING ARCHITECTURAL DRAWINGS) FOR THE EXACT LOCATION OF EQUIPMENT INSTALLED UNDER OTHER DIVISIONS OF THE DOCUMENTS WHICH REQUIRE ELECTRICAL SERVICE. CAPITAL LETTER BESIDE LIGHTING SYMBOL INDICATES FIXTURE TYPE. REFER TO LIGHTING FIXTURE SCHEDULE FOR FIXTURE SELECTION. EQUIPMENT GROUNDING CONDUCTORS ARE TO BE INCLUDED IN ALL RACEWAYS AND CABLES. REFER TO SPRINKLER FIRE PROTECTION SHOP DRAWINGS FOR ALL FLOW AND TAMPER SWITCH LOCATIONS AND CONNECTIONS FOR THE FIRE ALARM SYSTEM. REFER TO ARCHITECTURAL DOOR SCHEDULES FOR DOORS REQUIRING FIRE ALARM SYSTEM INTERFACE AND SMOKE OPERATION. PROVIDE 120V POWER AND FIRE ALARM CONNECTION TO ALL FIRE/SMOKE AND SMOKE DAMPERS INDICATED ON THE MECHANICAL DRAWINGS. WHERE ANY DAMPER IS EQUIPPED WITH INTEGRAL SMOKE DETECTOR, PROVIDE A ZONE ADDRESSABLE MODULE FOR CONNECTION TO FIRE ALARM SYSTEM WIRING. IN BUILDINGS WITH MULTIPLE SERVICES, THE CONTRACTOR SHALL PROVIDE A PLAQUE AT EACH SERVICE EQUIPMENT LOCATION DENOTING ALL OTHER SERVICES IN THE BUILDING AND THE AREA SERVED BY EACH. ANY CABLE ROUTED TO A WALL SWITCH CONTROLLING LIGHTING SHALL CONTAIN A GROUNDED CONDUCTOR (NEUTRAL), IN ADDITION TO AN EQUIPMENT GROUNDING CONDUCTOR. CONTRACTOR SHALL ENSURE TO THE GREATEST EXTENT POSSIBLE THAT LOADS ON THE ELECTRICAL DISTRIBUTION SYSTEM ARE PHASED-BALANCED. WHERE MULTI- METER PACKS ARE INSTALLED, EQUIPMENT LUGS SHALL BE ADJUSTED ACCORDINGLY TO BALANCE PHASES. FIRE ALARM INITIATING DEVICES LOCATED IN ELEVATOR SHAFTS ARE REQUIRED TO BE ACCESSIBLE FOR SERVICE, TESTING, AND MAINTENANCE FROM OUTSIDE THE ELEVATOR HOISTWAY PER NFPA 72 20.3.7. WHERE CIRCUIT BREAKERS OR FUSES ARE SERIES COMBINATION RATED, THE ENCLOSURE FOR THE OVERCURRENT DEVICES SHALL BE CLEARLY AND LEGIBLY MARKED IN THE FIELD TO INDICATE THE EQUIPMENT HAS BEEN APPLIED WITH A SERIES COMBINATION RATING. THE MARKING SHALL BE READILY VISIBLE AND STATE THE FOLLOWING: CAUTION -SERIES COMBINATION SYSTEM RATED ____ AMPERES. IDENTIFIED REPLACEMENT COMPONENTS REQUIRED. FEEDERS FOR THE EMERGENCY BRANCH OF ELECTRICAL DISTRIBUTION SHALL BE PROTECTED FROM FIRE PER THE REQUIREMENTS OF NEC ARTICLE 700. A LISTED CIRCUIT-PROTECTIVE SYSTEM, THERMAL BARRIER, THERMAL ASSEMBLY (CONTAINING ONLY EMERGENCY FEEDERS) OR CONCRETE ENCASEMENT IS NOT REQUIRED WHERE FEEDERS ARE INSTALLED IN SPACES OR AREAS THAT ARE FULLY PROTECTED BY AN APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEM. FOR THIS REQUIREMENT, AN UNSPRINKLERED CEILING CAVITY IS NOT CONSIDERED A PROTECTED SPACE OR AREA. THIS REQUIREMENT ALSO APPLIES TO CONTROL WIRING BETWEEN GENERATOR AND TRANSFER SWITCH(ES). POWER AND CONTROL WIRING TO STAIRWELL PRESSURIZATION EQUIPMENT (FANS, STARTERS, AND DAMPERS) SHALL BE INSTALLED BY ONE OR COMBINATION OF THE FOLLOWING METHODS: a. EXTERIOR TO BUILDING. b. WITHIN SMOKEPROOF ENCLOSURES c. ENCLOSED BY MINIMUM 2 HOUR FIRE BARRIERS OR HORIZONTAL ASSEMBLIES d. ENCASED IN MINIMUM OF 2" OF CONCRETE e. UTILIZING 2 HOUR RATED CABLE OR CABLE SYSTEM ALL WIRING AND CABLES TO DESIGNATED FIRE SERVICE ACCESS ELEVATOR MOTOR(S), CAB(S), MACHINE ROOM HVAC EQUIPMENT, CAB COMMUNICATION WIRING, AND FIRE ALARM SYSTEM INITIATING DEVICE CIRCUITS (LOCATED IN FIRE SERVICE ELEVATOR SHAFTS, LOBBIES, AND MACHINE ROOM) SHALL BE SUITABLY PROTECTED FROM FIRE PER THE REQUIREMENTS OF IBC 3007 (1-HOUR PER IBC 2009, 2-HOUR PER IBC 2012). WHERE APPROVED BY THE AHJ, WIRING AND CABLES LOCATED WITHIN THE FIRE SERVICE ELEVATOR HOISTWAY AND MACHINE ROOM ARE CONSIDERED PROTECTED. ELECTRICAL GENERAL NOTES DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:53:10 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE00.00 IMW MJS 2247601 ELECTRICAL TITLE SHEET SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS ELECTRICAL SHEET INDEX E00.00 ELECTRICAL TITLE SHEET E02.01A LEVEL 1 - FLOOR PLAN - AREA A E02.01B LEVEL 1 - FLOOR PLAN - AREA B E02.01C LEVEL 1 - FLOOR PLAN - AREA C E02.02A LEVEL 2 - FLOOR PLAN - AREA A E02.02B LEVEL 2 - FLOOR PLAN - AREA B E02.02C LEVEL 2 - FLOOR PLAN - AREA C E02.03A LEVEL 3 - FLOOR PLAN - AREA A E02.03B LEVEL 3 - FLOOR PLAN - AREA B E02.03C LEVEL 3 - FLOOR PLAN - AREA C E02.04A LEVEL 4 - FLOOR PLAN - AREA A E02.04B LEVEL 4 - FLOOR PLAN - AREA B E02.04C LEVEL 4 - FLOOR PLAN - AREA C E02.05A LEVEL 5 - FLOOR PLAN - AREA A E02.05B LEVEL 5 - FLOOR PLAN - AREA B E02.05C LEVEL 5 - FLOOR PLAN - AREA C E02.06A LEVEL 6 - FLOOR PLAN - AREA A E02.06B LEVEL 6 - FLOOR PLAN - AREA B E02.06C LEVEL 6 - FLOOR PLAN - AREA C E02.07A LEVEL 7 - FLOOR PLAN - AREA A E02.07B LEVEL 7 - FLOOR PLAN - AREA B E02.07C LEVEL 7 - FLOOR PLAN - AREA C E02.08A LEVEL 8 - FLOOR PLAN - AREA A E02.08B LEVEL 8 - FLOOR PLAN - AREA B E02.08C LEVEL 8 - FLOOR PLAN - AREA C E02.09A LEVEL 9-10 - FLOOR PLAN - AREA A E02.09B LEVEL 9-10 - FLOOR PLAN - AREA B E02.09C LEVEL 9-10 - FLOOR PLAN - AREA C E02.10A ROOF PLAN - AREA A E02.10B ROOF PLAN - AREA B E02.10C ROOF PLAN - AREA C E04.01 UNIT PLANS E04.02 UNIT PLANS E04.03 UNIT PLANS E04.04 UNIT PLANS E05.01 ELECTRICAL RISER DIAGRAM Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV K L M N P Q R U 7 6 5 S 8 T RESTAURANT 325 STAIR 5 1175 CIRCULATION 772 ELEVATOR 3 339 TRASH 385 RETAIL 791 F4 F4 F3 F3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:53:14 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.01A IMW MJS 2247601 LEVEL 1 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1" = 10'-0" LEVEL 1 -FLOOR PLAN -AREA A1 C D E F G H J 7 6 5 8 B OV XY BOH 531 ELEVATOR 2 1341 ELEVATOR 1 1342 LEASING/LOBBY 779 FITNESS 803 RETAIL 791 STAIR 2 824 MAIL ROOM 825 F4 F4 F3 F3 F3 F3 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:53:17 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.01B IMW MJS 2247601 LEVEL 1 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1" = 10'-0" LEVEL 1 -FLOOR PLAN -AREA B1 C D 9 10 11 13 14 16 17 8 B OV XY 15 12 RETAIL 330 STAIR 1 1203 STAIR 2 824 TRASH 967 RETAIL 974 RETAIL 812 F4 F4 RETAIL 973 4' - 0" E02.01C 2 9 O 4' - 0"4' - 0" RS1 RETAIL #1 400A C.T. FUTURE RETAIL 1-4 SERVICE TROUGH 1600A PHASE I RETAIL #2 400A C.T. FUTURE RETAIL#2 400A DISC. FUTURE RETAIL#1 400A DISC. FUTURE RETAIL#3 400A DISC. FUTURE RETAIL#4 400A DISC. FUTURE RETAIL #3 400A C.T. FUTURE RETAIL #4 400A C.T. FUTURE RETAIL 1 & 2 SERVICE TROUGH 1600A PHASE II HH HLT-HL RETAIL #2 400A C.T. FUTURE RETAIL#2 400A DISC. FUTURE RETAIL#1 400A DISC. FUTURE RETAIL #1 400A C.T. FUTURE RETAIL TROUGH PHASE II RETAIL TROUGH PHASE I 2500A PULL SECT. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 2:54:04 PM D:\Revit Projects\22020579-MCRT Foundry-E-r22_Central_mfrenchH69FY.rvtE02.01C IMW MJS 2247601 LEVEL 1 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1" = 10'-0" LEVEL 1 -FLOOR PLAN -AREA C1 Scale: 1/4" = 1'-0" ELECTRIACL ROOM RETAIL & RS12 K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T GARAGE 320 STAIR 5 1176 CIRCULATION 1317 ELEVATOR 3 340 BOH 701 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:53:24 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.02A IMW MJS 2247601 LEVEL 2 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA A1 C D E F G H J 4 7 6 5 1 2 8 3 B OV XY STAIR 3 1184 ELEVATOR 2 1343 ELEVATOR 1 1344 BOH 632 CIRCULATION 643 STAIR 2 800 F4 F4 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:53:27 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.02B IMW MJS 2247601 LEVEL 2 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA B1 C D 9 10 11 13 14 16 17 8 B 15 12 STAIR 1 1204 STAIR 2 800 TRASH 959 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:53:31 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.02C IMW MJS 2247601 LEVEL 2 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 2 -FLOOR PLAN -AREA C1 K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T ELEC ROOM 688 STAIR 5 1177 ELEVATOR 3 341 TRASH 371 UNIT A2 841 BOH 842 UNIT AD2 844 UNIT S2 845 UNIT AD2 871 UNIT A5 872 GARAGE 873 BOH 1424 UNIT A4 1421 PET SPA 1433 TELECOM 904 UNIT A6 499 UNIT S3 813 RESIDENTIAL STORAGE 400 F4 F4 T5 E02.03A 2 U 1 T PULL SECT. RS4 PULL SECT. RS3ELEC ROOM 688 T5 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 2:54:05 PM D:\Revit Projects\22020579-MCRT Foundry-E-r22_Central_mfrenchH69FY.rvtE02.03A IMW MJS 2247601 LEVEL 3 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA A1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM 6882 C D E F G H J 4 7 6 5 1 2 8 3 B OV XY E02.03B 2 RESIDENTIAL STORAGE 691 STAIR 3 1189 ELEVATOR 2 1345 ELEVATOR 1 1346 STAIR 2 804 UNIT B3 850 ELEC ROOM 851 CIRCULATION 927 TELECOM 899 UNIT B3 740 UNIT A6 497 UNIT A6 510 TELECOM 832 RESIDENTIAL STORAGE 399 F4 F4 F4 F4 ELEC ROOM 692 GARAGE 873 C 7 6 5 B GARAGE E.V. 225KVA E.V DIST. LOCATION TBD - DESIGN BASED ON NATURAL GAS GENERATOR - WILL INCREASE IN LENGTH IF DIESEL GENERATOR DESIRED, TO ACCOMODATE SKID TANK.600 ES200 EL1600ADIST.MAINDIST.PULL HHB FIRE COMMAND 1239 ELEC ROOM 692 LHBRS2 MTS-EL ATS-EL 1HEL 1LEL ATS-ES 1DHES 1LES T-1LES 1HEST-1LEL T-LHB DPEV LOW VOLTAGEEMERGENCY ELEC. RM. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 2:54:06 PM D:\Revit Projects\22020579-MCRT Foundry-E-r22_Central_mfrenchH69FY.rvtE02.03B IMW MJS 2247601 LEVEL 3 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ● Suite 100 Charlotte, NC 28217 p. 704.599.4377 ● f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA B1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE I -MAIN & GENERATOR2 C D 9 10 11 13 14 16 17 8 B 15 12 HP13 E02.03C 2 STAIR 1 1205 STAIR 2 804 ELEC ROOM 851 UNIT A2 854 BOH 855 UNIT B2 858 UNIT B2 859 UNIT B2 862 UNIT BA1 863 UNIT AU1 866 UNIT B10 485 UNIT AU1 506 UNIT B2 680 BOH 798 BOH 814 BOH 826 UNIT B2 956 UNIT AD2 957 TRASH 960 BOH 828 UNIT BA1 933 UNIT A2 934 TELECOM 935 UNIT BA1 936 UNIT A6 838 CIRCULATION 434 F4 F4 9 4' - 0"10' - 2"MC13 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:53:49 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.03C IMW MJS 2247601 LEVEL 3 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 3 -FLOOR PLAN -AREA C1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE II MC132 K L M N P Q R 4 U 7 6 5 1 2 S 8 3 T GARAGE 318 BOH 530 STAIR 5 1178 UNIT A2 616 BOH 623 UNIT AD2 630 UNIT S2 631 ELEVATOR 3 343 TRASH 372 UNIT AD2 834 UNIT A5 839 UNIT A4 929 BOH 1441 UNIT A6 458 UNIT S3 361 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:53:55 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.04A IMW MJS 2247601 LEVEL 4 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA A1 C D E F G H J 4 7 6 5 1 2 8 3 B OV XY LOADING 321 STAIR 3 1190 CIRCULATION 1320 ELEVATOR 2 1347 ELEVATOR 1 1348 UNIT B3 741 ELEC ROOM 750 STAIR 2 805 RESIDENTIAL STORAGE 874 BOH 1430 BOH 1434 UNIT A6 433 UNIT B3 739 UNIT A6 511 F4 F4 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:00 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.04B IMW MJS 2247601 LEVEL 4 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA B1 C D 9 10 11 13 14 16 17 8 B 15 12 STAIR 1 1206 ELEC ROOM 750 STAIR 2 805 UNIT B2 642 UNIT B2 647 UNIT B2 683 UNIT AU1 735 UNIT B2 736 UNIT B10 481 UNIT AU1 504 BOH 770 BOH 780 BOH 795 TRASH 961 UNIT AD2 968 BOH 926 UNIT A2 937 BOH 938 UNIT BA1 939 UNIT BA1 940 UNIT A2 941 BOH 942 UNIT BA1 943 UNIT A6 836 UNIT B2.1 428 CIRCULATION 438 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:06 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.04C IMW MJS 2247601 LEVEL 4 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 4 -FLOOR PLAN -AREA C1 4 U 7 6 5 1 2 8 3 MC35 E02.05A 2 STAIR 5 1179 BOH 796 ELEVATOR 3 344 TRASH 373 MAINTENENCE AND ENGINEERING 827 GARAGE 877 RESIDENTIAL STORAGE 394 TELECOM 898 UNIT A2 689 BOH 690 UNIT A4 391 UNIT A5 414 UNIT AD2 498 UNIT AD2 502 UNIT S2 865 STAIR 4 378 UNIT S3-A 488 UNIT A6 405 F4 F4 F4 F4 MC35 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:12 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.05A IMW MJS 2247601 LEVEL 5 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA A1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE I -MC352 4 7 6 5 1 2 8 3 E02.05B 2 MC25 STAIR 3 1191 ELEVATOR 2 1349 ELEVATOR 1 1350 BOH 568 CIRCULATION 774 STAIR 2 806 MAINTENENCE AND ENGINEERING 827 ELEC ROOM 878 RESIDENTIAL STORAGE 379 POOL EQUIP AND STORAGE ROOM 1431 UNIT B3 763 UNIT B3 764 TELECOM 846 LONG TERM BIKE STORAGE 671 UNIT B2 823 UNIT A6 401 UNIT A6 403 F4 F4 F4 F4 7 MC25 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:17 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.05B IMW MJS 2247601 LEVEL 5 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA B1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE I -MC252 9 10 11 13 14 16 17 8 15 12 STAIR 1 1207 STAIR 2 806 ELEC ROOM 878 BOH 875 BOH 889 BOH 894 UNIT AU1 514 UNIT AU1 518 UNIT B2 706 UNIT B2 708 UNIT B2 720 UNIT B2 721 UNIT B10 807 TRASH 962 UNIT AD2 969 BOH 928 UNIT A2 944 BOH 945 UNIT BA1 948 UNIT A2 949 TELECOM 950 UNIT BA1-A 486 UNIT BA1-A 487 UNIT B2 823 UNIT A6 833 UNIT B2.1 427 CIRCULATION 432 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:23 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.05C IMW MJS 2247601 LEVEL 5 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 5 -FLOOR PLAN -AREA C1 MC36 E02.06A 2 STAIR 5 1074 UNIT A1 435 UNIT A1 436 UNIT A1 437 UNIT A1 440 UNIT B1 448 BOH 449 UNIT B1 450 BOH 451 UNIT B1 452 BOH 453 UNIT B1 460 BOH 462 UNIT B1 464 BOH 469 UNIT BA1.1 482 UNIT AD2 513 UNIT B2 521 UNIT S2 522 UNIT A7 523 AMENITY 727 COURTYARD B 731 UNIT A7 751 UNIT A1 352 UNIT A1 353 ELEVATOR 3 338 TRASH 367 UNIT AD2 742 UNIT S4 402 UNIT A4 1425 UNIT A5 419 UNIT AD2 470 UNIT BA1.1 979 UNIT B2.1 566 UNIT B5 820 STAIR 4 362 BOH 392 UNIT A2-A 634 UNIT A6 411 F4 F4 F4 F4 6' - 5 5/16" MC36 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:32 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.06A IMW MJS 2247601 LEVEL 6 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA A1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE I -MC362 STAIR 3 947 CIRCULATION 1186 ELEVATOR 2 1339 ELEVATOR 1 1340 UNIT A1 442 UNIT A1 444 UNIT A1 445 UNIT A1 446 UNIT A7 447 UNIT B1 474 BOH 475 UNIT B1 476 BOH 477 UNIT B1 478 BOH 479 UNIT A5 483 UNIT A1 484 UNIT B6 500 UNIT B2 501 UNIT B6 507 ELEC ROOM 528 COURTYARD A 728 POOL 729 UNIT S2 730 COURTYARD C 733 UNIT A1 354 UNIT A1 333 UNIT B6 335 BOH 792 STAIR 2 793 UNIT AD2 461 PRIVATE TERRACES 454 PRIVATE TERRACES 455 UNIT A6 516 UNIT BA1 978 UNIT A6 406 UNIT A6 411 F4 F4 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:39 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.06B IMW MJS 2247601 LEVEL 6 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA B1 4' - 0"10' - 2"STAIR 1 975 UNIT B2 501 UNIT B2 515 UNIT B2 517 ELEC ROOM 528 UNIT B2 760 UNIT B2 762 UNIT AU1 336 STAIR 2 793 UNIT A6 387 UNIT AU1 503 TRASH 958 UNIT AD2 970 UNIT B2.1 891 BOH 829 BOH 843 BOH 890 BOH 930 UNIT A2 952 BOH 953 UNIT BA1 954 UNIT BA1 955 UNIT BA1 977 UNIT B10 821 UNIT A2-A 489 CIRCULATION 431 F4 F4 E02.06C 2 MC16 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:47 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.06C IMW MJS 2247601 LEVEL 6 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 6 -FLOOR PLAN -AREA C1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE II MC162 STAIR 5 1180 UNIT A1 537 UNIT A1 538 UNIT A1 539 UNIT A1 541 UNIT B1 548 BOH 549 UNIT B1 550 BOH 551 UNIT B1 552 BOH 553 UNIT B1 554 BOH 555 UNIT B1 556 BOH 557 UNIT A2 579 BOH 580 UNIT AD2 599 UNIT A5 604 UNIT B2 608 UNIT S2 609 UNIT A7 610 UNIT A7 612 ELEVATOR 3 346 TRASH 376 UNIT A3 1371 UNIT A3 1372 UNIT AD2 1375 UNIT S4 410 UNIT A4 1426 UNIT BA1.1 761 UNIT BA1.1 767 UNIT B2.1 575 UNIT B5 818 STAIR 4 381 UNIT AD2 1211 BOH 1227UNIT A6 415 F4 F4 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:54:55 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.07A IMW MJS 2247601 LEVEL 7 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA A1 MC27 E02.07B 2 STAIR 3 1192 CIRCULATION 1187 ELEVATOR 2 1351 ELEVATOR 1 1352 UNIT A1 543 UNIT A1 544 UNIT A1 545 UNIT A1 546 UNIT A7 547 UNIT B1 558 BOH 559 UNIT B1 560 BOH 561 UNIT B1 562 BOH 563 UNIT A1 570 UNIT A1 572 UNIT B6 586 UNIT B6 594 ELEC ROOM 607 UNIT A2 613 BOH 614 STAIR 2 808 BOH 830 UNIT A3 1373 UNIT B6 1376 UNIT B2 535 UNIT A6 524 UNIT BA1 527 UNIT A5 1200 UNIT AD2 1210 UNIT A6 413 UNIT A6 415 F4 F4 F4 F4 MC27 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:55:03 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.07B IMW MJS 2247601 LEVEL 7 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA B1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE I -MC272 STAIR 1 1208 ELEC ROOM 607 STAIR 2 808 UNIT B2 1386 UNIT B2 1387 UNIT B2 1389 UNIT B2 1391 UNIT AU1 1392 UNIT B10 473 UNIT A6 532 UNIT B2 535 UNIT AU1 505 TRASH 963 UNIT AD2 971 UNIT B2.1 583 BOH 913 BOH 918 BOH 920 BOH 931 UNIT A2 980 BOH 981 UNIT BA1 982 UNIT BA1 983 UNIT A2 984 TELECOM 985 UNIT BA1 986 CIRCULATION 430 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:55:09 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.07C IMW MJS 2247601 LEVEL 7 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 7 -FLOOR PLAN -AREA C1 MC48 E02.08A 2 STAIR 5 1181 UNIT A1 644 UNIT A1 645 UNIT A1 646 UNIT A1 648 UNIT B1 655 BOH 656 UNIT B1 657 BOH 658 UNIT B1 659 BOH 660 UNIT B1 661 BOH 662 UNIT B1 663 BOH 664 UNIT B5 678 UNIT A2 684 BOH 693 UNIT B6 703 UNIT AD2 707 UNIT A5 709 UNIT B2 713 UNIT S2 714 UNIT A7 715 UNIT A7 717 UNIT A3 355 UNIT A3 356 ELEVATOR 3 350 TRASH 377 UNIT A5 1322 UNIT AD2 1326 UNIT S4 409 UNIT A4 1427 UNIT BA1.1 790 UNIT BA1.1 860 UNIT B2.1 596 STAIR 4 383 UNIT AD2 1226 BOH 1232 UNIT S3-A 492 UNIT A6 421 F4 F4 F4 F4 17' - 0"6' - 5 5/16" MC48 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:55:19 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.08A IMW MJS 2247601 LEVEL 8 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA A1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE I -MC482 NEED LOCATION STAIR 3 1193 CIRCULATION 1319 ELEVATOR 2 1353 ELEVATOR 1 1354 UNIT A1 650 UNIT A1 651 UNIT A1 652 UNIT A1 653 UNIT A7 654 UNIT B1 665 BOH 666 UNIT B1 667 BOH 668 UNIT B1 669 BOH 670 UNIT A1 675 UNIT A1 677 UNIT B6 699 UNIT B6 702 UNIT A3 357 STAIR 2 809 BOH 879 UNIT B6 1325 ELEC ROOM 1328 UNIT B2 542 UNIT A6 533 UNIT A5 1222 UNIT AD2 1225 UNIT BA1-A 490 UNIT A2-A 637 UNIT A6 420 UNIT A6 421 F4 F4 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:55:27 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.08B IMW MJS 2247601 LEVEL 8 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA B1 STAIR 1 1209 STAIR 2 809 ELEC ROOM 1328 UNIT B2 1338 UNIT B2 1359 UNIT B2 1365 UNIT B2 1377 UNIT AU1 1378 UNIT B10 472 UNIT A6 534 UNIT B2 542 UNIT AU1 508 TRASH 964 UNIT AD2 972 UNIT B2.1 598 BOH 921 BOH 923 BOH 924 BOH 932 UNIT A2 987 BOH 988 UNIT BA1 989 UNIT BA1 990 UNIT BA1 993 UNIT A2-A 491 CIRCULATION 429 F4 F4 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:55:34 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.08C IMW MJS 2247601 LEVEL 8 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 8 -FLOOR PLAN -AREA C1 MC49 E02.09A 2 STAIR 5 1182 ELEVATOR 3 351 TRASH 380 UNIT A1 564 UNIT A1 565 UNIT A1 571 UNIT A1 573 UNIT B1 584 BOH 585 UNIT B1 587 BOH 588 UNIT B1 589 BOH 590 UNIT B1 591 BOH 592 UNIT B1 595 BOH 597 UNIT A2 682 BOH 697 UNIT B6 716 UNIT AD2 722 UNIT A5 723 UNIT B2 726 UNIT A7 734 UNIT A7 743 UNIT A3 746 UNIT A3 747 UNIT AD2 757 UNIT S4 766 UNIT A5 752 UNIT A4 1428 UNIT B5 359 UNIT S2 848 UNIT BA1.1 861 UNIT BA1.1 867 UNIT B2.1 624 UNIT S3 816 STAIR 4 386 UNIT AD2 1221 BOH 1235UNIT A6 424 F4 F4 F4 F4 17' - 0"6' - 5 5/16" MC49 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:55:43 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.09A IMW MJS 2247601 LEVEL 9-10 - FLOOR PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 9-10 -FLOOR PLAN -AREA A1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE I -MC492 NEED LOCATION MC29 E02.09B 2 STAIR 3 1194 CIRCULATION 1318 ELEVATOR 2 1355 ELEVATOR 1 1356 STAIR 2 810 BOH 412 UNIT A1 576 UNIT A1 577 UNIT A1 578 UNIT A1 581 UNIT A7 582 UNIT B1 601 BOH 602 UNIT B1 603 BOH 611 UNIT B1 615 BOH 622 UNIT A1 629 UNIT A1 633 UNIT B6 700 UNIT B6 705 UNIT A2 744 BOH 745 UNIT A3 748 UNIT B6 756 ELEC ROOM 759 UNIT A6 536 UNIT BA1 593 UNIT A5 1217 UNIT AD2 1220 UNIT A6 422 UNIT A6 424 F4 F4 F4 F4 MC29 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:55:51 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.09B IMW MJS 2247601 LEVEL 9-10 - FLOOR PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 9-10 -FLOOR PLAN -AREA B1 Scale: 1/8" = 1'-0" ELECTRICAL ROOM PHASE I -MC292 STAIR 2 810 ELEC ROOM 759 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:55:55 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.09C IMW MJS 2247601 LEVEL 9-10 - FLOOR PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LEVEL 9-10 -FLOOR PLAN -AREA C1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:56:00 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.10A IMW MJS 2247601 ROOF PLAN - AREA A SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" HIGH ROOF -AREA A1 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:56:06 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.10B IMW MJS 2247601 ROOF PLAN - AREA B SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" HIGH ROOF -AREA B1 CIRCULATION 1318 ELEVATOR 2 1355 ELEVATOR 1 1356 STAIR 2 810 BOH 412 BOH 611 ELEC ROOM 759 UNIT A6 536 UNIT BA1 593 DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:56:10 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE02.10C IMW MJS 2247601 ROOF PLAN - AREA C SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/8" = 1'-0" LOW ROOF -AREA C (NORTH)1Scale: 1/8" = 1'-0" LOW ROOF -AREA C (SOUTH)2 J H HSA CATVTVJCASA H H TVTVPANEL 2 1 7 6 5 4 8 8 3 10 WP GENERAL NOTES 1. LOCATION OF SMOKE ALARMS SHALL BE NO LESS THAN 36" FROM A BATHROOM DOOR, SUPPLY AIR REGISTER, OR TIP OF A CEILING FAN BLADE, AND SHALL BE NO LESS THAN 10' FROM A FIXED COOKING APPLIANCE. WHERE WALL MOUNTED, TOP OF DEVICE SHALL BE NO GREATER THAN 12" FROM CEILING. COORDINATE LOCATION WITH SOFFITS AND CROWN MOLDING (WHERE PRESENT). 2. SMOKE AND CO ALARMS SHALL BE WIRED TO AN UNSWITCHED LIGHTING AND RECEPTACLE CIRCUIT. ALARM DEVICES WITHIN A DWELLING UNIT SHALL BE PROVIDED WITH AUXILIARY CONTACTS AND WIRED SO THAT UPON THE ACTIVATION OF ANY ALARM IN THE DWELLING UNIT, ALL SMOKE AND CO ALARMS WITHIN THE DWELLING SHALL SIGNAL AN ALARM. 3. REFER TO "ELECTRICAL DEVICES-DWELLING UNIT KITCHEN" DETAIL INCLUDED IN THESE DRAWINGS FOR DIMENSIONAL INFORMATION OF DEVICES AT CORNERS (WHERE APPLICABLE). 4. ALL 120V, 15-AND 20-AMP RECEPTACLES IN DWELLING UNITS SHALL BE LISTED TAMPER-RESISTANT TYPE. 5. OUTLET BOXES INSTALLED FOR CEILING FANS SHALL BE UL-LISTED "FOR USE WITH CEILING FANS". 6. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR APPLICABLE CIRCUIT REQUIREMENTS. 7. PRIOR TO ROUGH-IN, CONTRACTOR SHALL: • COORDINATE EXACT REQUIREMENTS OF ALL EQUIPMENT AND APPLIANCES FURNISHED BY OTHERS. • COORDINATE LIGHTING FIXTURE LOCATIONS WITH ARCHITECTURAL/INTERIORS DRAWINGS. 8. SEVERAL DWELLING UNIT CIRCUITS AND RECEPTACLES ARE REQUIRED TO BE AFCI- AND/OR GFCI-PROTECTED. REFER TO DRAWINGS AND LOAD CENTER SCHEDULES FOR MORE INFORMATION. 9. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES : • LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS GREATER THAN 48" AFF. • TOGGLE SWITCHES SHALL BE FIELD-INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCHES SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES AND CONTROL THE LIGHTS INDEPENDENT OF THE FAN . 10. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION): • FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM (CAT# 7005-G5), CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE (CAT# 147-10) OUTSIDE OF ENTRY DOOR, TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVING ROOM. • EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. • A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. • REFER TO DETAIL INCLUDED IN THESE DRAWINGS FOR WIRING DIAGRAM OF SMOKE ALARMS AND FIRE ALARM DEVICES. 11. FOR EACH DWELLING UNIT LOCATED AT GRADE-LEVEL OR ON A FLOOR ACCESSIBLE BY ELEVATOR: • LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS GREATER THAN 48"AFF. • FOR ALL DESIGNATED "ANSI TYPE A" UNITS, TOGGLE SWITCHES SHALL BE FIELD-INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCHES SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES AND CONTROL THE LIGHT INDEPENDENT OF THE FAN. 12. UNLESS DIRECTED OTHERWISE, DESIGNATED "ANSI TYPE A" UNITS SHALL HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION): • FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM (CAT# 7005-G5), CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE (CAT# 147-10) OUTSIDE OF ENTRY DOOR, TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVING ROOM. • EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. • A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. • REFER TO DETAIL INCLUDED IN THESE DRAWINGS FOR WIRING DIAGRAM OF SMOKE ALARMS AND FIRE ALARM DEVICES. 13. WHERE APPLICABLE, KITCHEN RECEPTACLE CIRCUIT SHALL POWER GAS COOKTOP IGNITER. 14. RECEPTACLE LAYOUTS SHOWN IN UNITS ARE BASED ON MINIMUM NEC REQUIREMENTS. CONTRACTOR SHALL REVIEW LAYOUTS AND PROVIDE ANY ADDITIONAL RECEPTACLES NEEDED TO BE IN COMPLIANCE WITH NEC BASED ON ACTUAL FIELD INSTALLED LOCATIONS. KEY NOTES (DESIGNATED BY " # ") 1. NEMA 5-20R FOR CLOTHES WASHER. CIRCUIT SHALL BE 2#12, #12G. 2. NEMA 14-30R FOR CLOTHES DRYER. CIRCUIT SHALL BE 3#10, #10G. 3. NEMA 14-50R FOR RANGE/OVEN. CIRCUIT SHALL BE 3#6, #10G. 4. NEMA 5-20R FOR MICROWAVE/EXHAUST HOOD. CIRCUIT SHALL BE 2#12, #12G. LOCATE RECEPTACLE IN CABINETRY ABOVE. RECEPTACLE MAY BE LOCATED BELOW COUNTER IN ACCESSIBLE UNITS. REFER TO ARCHITECTURAL KITCHEN ELEVATIONS FOR FURTHER INFORMATION. 5. FOR SINK DISPOSAL/DISHWASHER CONNECTION, INSTALL SPLIT-WIRED NEMA 5-20R DUPLEX WITHIN BASE CABINET. RECEPTACLE SHALL BE ACCESSIBLE AND LOCATED IN CABINET ADJACENT TO DISHWASHER. DISHWASHER CORD LENGTH SHALL NOT EXCEED 6'-6". 6. DISCONNECT SWITCH FOR AIR-HANDLING UNIT. 7. JUNCTION BOX FOR CONNECTION TO WATER HEATER. CIRCUIT SHALL BE 2#10, 1# 10G. 8. INSTALL RECEPTACLE NO MORE THAN 12" BELOW COUNTERTOP, PROVIDED THAT THE COUNTERTOP EXTENDS NO MORE THAN 6" BEYOND ITS SUPPORT BASE. 9. PROVIDE JUNCTION BOX FOR POWER TO OUTSIDE AIR FAN (OAF), SPEED CONTROLLER AND RELAY PROVIDED BY DIVISION 23.OAF SHALL BE PROVIDED WITH MOTOR RATED DISCONNECT SWITCH AS PART OF THE MECHANICAL SUBMITTAL.CONTRACTOR SHALL COORDINATE AND INSTALL DISCONNECT TO MEET NEC WORKING CLEARANCE REQUIREMENTS.CONNECT TO THE NEAREST LIGHTING & RECEPTACLE CIRCUIT. COORDINATE EXACT REQUIEMENTS WITH THE MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. 10. PROVIDE RECEPTACLE FOR TELECOMMUNICATIONS STRUCTURED MEDIA CENTER PANEL (MP). COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH TELECOM DRAWINGS BEFORE INSTALLATION. PANEL 2 1 7 5 3 4 6 10 WP DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:56:16 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE04.01 IMW MJS 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/4" = 1'-0" UNIT A12 Scale: 1/4" = 1'-0" UNIT S21 RECEPTACLE WOULD FOLLOW MEASURED AS THE SHORTEST PATH THE CORD OF AN APPLIANCE CONNECTED TO THE *GFCI NOT REQUIRED WHERE RECEPTACLE IS MORE THAN 6FT FROM THE EDGE OF A SINK 48" AFF. DESIGNATED IBC ACCESSIBLE, TYPE A OR B, MAXIMUM HEIGHT TO ANY DEVICE HANDLE SHALL BE 2. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES, OR THOSE DEVICE SO THAT CIRCUITS CAN BE DISCONNECTED SIMULTANEOUSLY. NOTES:1. BREAKERS PROTECTING MULTI-WIRE BRANCH CIRCUITS SHALL BE EQUIPPED WITH A PAD-LOCK 23 SPACE SPACE 24 21 -----SPACE 22 19 15/2 OUTDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 20 17 -----LIGHTS & RECEPTACLES AFCI 15/1 18 15 35/2 INDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 16 13 -----REFRIGERATOR AFCI/GFCI 15/1*14 11 30/2 LOCKOFF WATER HEATER BATHROOM CIRCUIT 20/1 12 9 20/1*AFCI/GFCI MICROWAVE OVEN WASHER AFCI/GFCI 20/1 10 7 -----DISPOSAL AFCI/GFCI 20/1 8 5 30/2 GFCI DRYER DISHWASHER AFCI/GFCI 20/1 6 3 -----KIT/DINING RECEPTACLES AFCI 20/1 4 1 50/2*GFCI RANGE KITCHEN RECEPTACLES AFCI 20/1 2 #POLES TYPE A B TYPE POLES # CKT TRIP /BKR DESCRIPTION PHASE DESCRIPTION BKR TRIP /CKT MAIN:125A MLO VOLTAGE:208/120 PHASE:1 WIRE:3 RECESSED AIC:10,000 LOAD CENTER SCHEDULE - A1 VOLTAGE:208/120 PHASE:1 107.5 AMPS TOTAL 22.4 KVA N.E.C. 220-82 HVAC (HEATING)4.2 KVA X 65 %2.7 KVA HVAC (COOLING)N/A KVA X 100 %KVA HVAC (HEAT PUMP)2.0 KVA X 100 %2.0 KVA REMAINDER 19.1 KVA X 40 %7.6 KVA 1ST 10 KW 10.0 KVA X 100 %10.0 KVA DEMAND FACTOR SUBTOTAL 29.1 KVA WATER HEATERS 4500 VA 4.5 KVA MICROWAVE/HOOD 1500 VA 1.5 KVA DISHWASHERS 1200 VA 1.2 KVA DISPOSALS 800 VA 0.8 KVA REFRIGERAT...1500 VA 1.5 KVA DRYERS 5000 VA 5.0 KVA RANGES 8000 VA 8.0 KVA KITCHEN/LAUNDRY 4500 VA 4.5 KVA SQUARE FOOTAGE 699 SF X 3 VA/SF 2.1 KVA UNIT "A1" RECEPTACLE WOULD FOLLOW MEASURED AS THE SHORTEST PATH THE CORD OF AN APPLIANCE CONNECTED TO THE *GFCI NOT REQUIRED WHERE RECEPTACLE IS MORE THAN 6FT FROM THE EDGE OF A SINK 48" AFF. DESIGNATED IBC ACCESSIBLE, TYPE A OR B, MAXIMUM HEIGHT TO ANY DEVICE HANDLE SHALL BE 2. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES, OR THOSE DEVICE SO THAT CIRCUITS CAN BE DISCONNECTED SIMULTANEOUSLY. NOTES:1. BREAKERS PROTECTING MULTI-WIRE BRANCH CIRCUITS SHALL BE EQUIPPED WITH A PAD-LOCK 23 SPACE SPACE 24 21 -----SPACE 22 19 15/2 OUTDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 20 17 -----LIGHTS & RECEPTACLES AFCI 15/1 18 15 35/2 INDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 16 13 -----REFRIGERATOR AFCI/GFCI 15/1*14 11 30/2 LOCKOFF WATER HEATER BATHROOM CIRCUIT 20/1 12 9 20/1*AFCI/GFCI MICROWAVE OVEN WASHER AFCI/GFCI 20/1 10 7 -----DISPOSAL AFCI/GFCI 20/1 8 5 30/2 GFCI DRYER DISHWASHER AFCI/GFCI 20/1 6 3 -----KIT/DINING RECEPTACLES AFCI 20/1 4 1 50/2*GFCI RANGE KITCHEN RECEPTACLES AFCI 20/1 2 #POLES TYPE A B TYPE POLES # CKT TRIP /BKR DESCRIPTION PHASE DESCRIPTION BKR TRIP /CKT MAIN:125A MLO VOLTAGE:208/120 PHASE:1 WIRE:3 RECESSED AIC:10,000 LOAD CENTER SCHEDULE - S2 VOLTAGE:208/120 PHASE:1 107.0 AMPS TOTAL 22.2 KVA N.E.C. 220-82 HVAC (HEATING)4.2 KVA X 65 %2.7 KVA HVAC (COOLING)N/A KVA X 100 %KVA HVAC (HEAT PUMP)2.0 KVA X 100 %2.0 KVA REMAINDER 18.8 KVA X 40 %7.5 KVA 1ST 10 KW 10.0 KVA X 100 %10.0 KVA DEMAND FACTOR SUBTOTAL 28.8 KVA WATER HEATERS 4500 VA 4.5 KVA MICROWAVE/HOOD 1500 VA 1.5 KVA DISHWASHERS 1200 VA 1.2 KVA DISPOSALS 800 VA 0.8 KVA REFRIGERAT...1500 VA 1.5 KVA DRYERS 5000 VA 5.0 KVA RANGES 8000 VA 8.0 KVA KITCHEN/LAUNDRY 4500 VA 4.5 KVA SQUARE FOOTAGE 599 SF X 3 VA/SF 1.8 KVA UNIT "S2" J HHSACATVTVJCASAHHTVTVPANEL 6 7 34 1 2 5 8 8 10 WP PANEL 8 67 1 2 4 3 5 8 10 WP GENERAL NOTES 1. LOCATION OF SMOKE ALARMS SHALL BE NO LESS THAN 36" FROM A BATHROOM DOOR, SUPPLY AIR REGISTER, OR TIP OF A CEILING FAN BLADE, AND SHALL BE NO LESS THAN 10' FROM A FIXED COOKING APPLIANCE. WHERE WALL MOUNTED, TOP OF DEVICE SHALL BE NO GREATER THAN 12" FROM CEILING. COORDINATE LOCATION WITH SOFFITS AND CROWN MOLDING (WHERE PRESENT). 2. SMOKE AND CO ALARMS SHALL BE WIRED TO AN UNSWITCHED LIGHTING AND RECEPTACLE CIRCUIT. ALARM DEVICES WITHIN A DWELLING UNIT SHALL BE PROVIDED WITH AUXILIARY CONTACTS AND WIRED SO THAT UPON THE ACTIVATION OF ANY ALARM IN THE DWELLING UNIT, ALL SMOKE AND CO ALARMS WITHIN THE DWELLING SHALL SIGNAL AN ALARM. 3. REFER TO "ELECTRICAL DEVICES-DWELLING UNIT KITCHEN" DETAIL INCLUDED IN THESE DRAWINGS FOR DIMENSIONAL INFORMATION OF DEVICES AT CORNERS (WHERE APPLICABLE). 4. ALL 120V, 15-AND 20-AMP RECEPTACLES IN DWELLING UNITS SHALL BE LISTED TAMPER-RESISTANT TYPE. 5. OUTLET BOXES INSTALLED FOR CEILING FANS SHALL BE UL-LISTED "FOR USE WITH CEILING FANS". 6. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR APPLICABLE CIRCUIT REQUIREMENTS. 7. PRIOR TO ROUGH-IN, CONTRACTOR SHALL: • COORDINATE EXACT REQUIREMENTS OF ALL EQUIPMENT AND APPLIANCES FURNISHED BY OTHERS. • COORDINATE LIGHTING FIXTURE LOCATIONS WITH ARCHITECTURAL/INTERIORS DRAWINGS. 8. SEVERAL DWELLING UNIT CIRCUITS AND RECEPTACLES ARE REQUIRED TO BE AFCI- AND/OR GFCI-PROTECTED. REFER TO DRAWINGS AND LOAD CENTER SCHEDULES FOR MORE INFORMATION. 9. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES : • LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS GREATER THAN 48" AFF. • TOGGLE SWITCHES SHALL BE FIELD-INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCHES SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES AND CONTROL THE LIGHTS INDEPENDENT OF THE FAN . 10. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION): • FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM (CAT# 7005-G5), CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE (CAT# 147-10) OUTSIDE OF ENTRY DOOR, TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVING ROOM. • EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. • A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. • REFER TO DETAIL INCLUDED IN THESE DRAWINGS FOR WIRING DIAGRAM OF SMOKE ALARMS AND FIRE ALARM DEVICES. 11. FOR EACH DWELLING UNIT LOCATED AT GRADE-LEVEL OR ON A FLOOR ACCESSIBLE BY ELEVATOR: • LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS GREATER THAN 48"AFF. • FOR ALL DESIGNATED "ANSI TYPE A" UNITS, TOGGLE SWITCHES SHALL BE FIELD-INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCHES SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES AND CONTROL THE LIGHT INDEPENDENT OF THE FAN. 12. UNLESS DIRECTED OTHERWISE, DESIGNATED "ANSI TYPE A" UNITS SHALL HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION): • FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM (CAT# 7005-G5), CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE (CAT# 147-10) OUTSIDE OF ENTRY DOOR, TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVING ROOM. • EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. • A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. • REFER TO DETAIL INCLUDED IN THESE DRAWINGS FOR WIRING DIAGRAM OF SMOKE ALARMS AND FIRE ALARM DEVICES. 13. WHERE APPLICABLE, KITCHEN RECEPTACLE CIRCUIT SHALL POWER GAS COOKTOP IGNITER. 14. RECEPTACLE LAYOUTS SHOWN IN UNITS ARE BASED ON MINIMUM NEC REQUIREMENTS. CONTRACTOR SHALL REVIEW LAYOUTS AND PROVIDE ANY ADDITIONAL RECEPTACLES NEEDED TO BE IN COMPLIANCE WITH NEC BASED ON ACTUAL FIELD INSTALLED LOCATIONS. KEY NOTES (DESIGNATED BY " # ") 1. NEMA 5-20R FOR CLOTHES WASHER. CIRCUIT SHALL BE 2#12, #12G. 2. NEMA 14-30R FOR CLOTHES DRYER. CIRCUIT SHALL BE 3#10, #10G. 3. NEMA 14-50R FOR RANGE/OVEN. CIRCUIT SHALL BE 3#6, #10G. 4. NEMA 5-20R FOR MICROWAVE/EXHAUST HOOD. CIRCUIT SHALL BE 2#12, #12G. LOCATE RECEPTACLE IN CABINETRY ABOVE. RECEPTACLE MAY BE LOCATED BELOW COUNTER IN ACCESSIBLE UNITS. REFER TO ARCHITECTURAL KITCHEN ELEVATIONS FOR FURTHER INFORMATION. 5. FOR SINK DISPOSAL/DISHWASHER CONNECTION, INSTALL SPLIT-WIRED NEMA 5-20R DUPLEX WITHIN BASE CABINET. RECEPTACLE SHALL BE ACCESSIBLE AND LOCATED IN CABINET ADJACENT TO DISHWASHER. DISHWASHER CORD LENGTH SHALL NOT EXCEED 6'-6". 6. DISCONNECT SWITCH FOR AIR-HANDLING UNIT. 7. JUNCTION BOX FOR CONNECTION TO WATER HEATER. CIRCUIT SHALL BE 2#10, 1# 10G. 8. INSTALL RECEPTACLE NO MORE THAN 12" BELOW COUNTERTOP, PROVIDED THAT THE COUNTERTOP EXTENDS NO MORE THAN 6" BEYOND ITS SUPPORT BASE. 9. PROVIDE JUNCTION BOX FOR POWER TO OUTSIDE AIR FAN (OAF), SPEED CONTROLLER AND RELAY PROVIDED BY DIVISION 23.OAF SHALL BE PROVIDED WITH MOTOR RATED DISCONNECT SWITCH AS PART OF THE MECHANICAL SUBMITTAL.CONTRACTOR SHALL COORDINATE AND INSTALL DISCONNECT TO MEET NEC WORKING CLEARANCE REQUIREMENTS.CONNECT TO THE NEAREST LIGHTING & RECEPTACLE CIRCUIT. COORDINATE EXACT REQUIEMENTS WITH THE MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. 10. PROVIDE RECEPTACLE FOR TELECOMMUNICATIONS STRUCTURED MEDIA CENTER PANEL (MP). COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH TELECOM DRAWINGS BEFORE INSTALLATION. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:56:22 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE04.02 IMW MJS 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/4" = 1'-0" UNIT A61 Scale: 1/4" = 1'-0" UNIT AD22 RECEPTACLE WOULD FOLLOW MEASURED AS THE SHORTEST PATH THE CORD OF AN APPLIANCE CONNECTED TO THE *GFCI NOT REQUIRED WHERE RECEPTACLE IS MORE THAN 6FT FROM THE EDGE OF A SINK 48" AFF. DESIGNATED IBC ACCESSIBLE, TYPE A OR B, MAXIMUM HEIGHT TO ANY DEVICE HANDLE SHALL BE 2. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES, OR THOSE DEVICE SO THAT CIRCUITS CAN BE DISCONNECTED SIMULTANEOUSLY. NOTES:1. BREAKERS PROTECTING MULTI-WIRE BRANCH CIRCUITS SHALL BE EQUIPPED WITH A PAD-LOCK 23 SPACE SPACE 24 21 -----SPACE 22 19 20/2 OUTDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 20 17 -----LIGHTS & RECEPTACLES AFCI 15/1 18 15 50/2 INDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 16 13 -----REFRIGERATOR AFCI/GFCI 15/1*14 11 30/2 LOCKOFF WATER HEATER BATHROOM CIRCUIT 20/1 12 9 20/1*AFCI/GFCI MICROWAVE OVEN WASHER AFCI/GFCI 20/1 10 7 -----DISPOSAL AFCI/GFCI 20/1 8 5 30/2 GFCI DRYER DISHWASHER AFCI/GFCI 20/1 6 3 -----KIT/DINING RECEPTACLES AFCI 20/1 4 1 50/2*GFCI RANGE KITCHEN RECEPTACLES AFCI 20/1 2 #POLES TYPE A B TYPE POLES # CKT TRIP /BKR DESCRIPTION PHASE DESCRIPTION BKR TRIP /CKT MAIN:125A MLO VOLTAGE:208/120 PHASE:1 WIRE:3 RECESSED AIC:10,000 LOAD CENTER SCHEDULE - AD2 VOLTAGE:208/120 PHASE:1 118.0 AMPS TOTAL 24.5 KVA N.E.C. 220-82 HVAC (HEATING)6.4 KVA X 65 %4.2 KVA HVAC (COOLING)N/A KVA X 100 %KVA HVAC (HEAT PUMP)2.5 KVA X 100 %2.5 KVA REMAINDER 19.7 KVA X 40 %7.9 KVA 1ST 10 KW 10.0 KVA X 100 %10.0 KVA DEMAND FACTOR SUBTOTAL 29.7 KVA WATER HEATERS 4500 VA 4.5 KVA MICROWAVE/HOOD 1500 VA 1.5 KVA DISHWASHERS 1200 VA 1.2 KVA DISPOSALS 800 VA 0.8 KVA REFRIGERAT...1500 VA 1.5 KVA DRYERS 5000 VA 5.0 KVA RANGES 8000 VA 8.0 KVA KITCHEN/LAUNDRY 4500 VA 4.5 KVA SQUARE FOOTAGE 896 SF X 3 VA/SF 2.7 KVA UNIT "AD2" RECEPTACLE WOULD FOLLOW MEASURED AS THE SHORTEST PATH THE CORD OF AN APPLIANCE CONNECTED TO THE *GFCI NOT REQUIRED WHERE RECEPTACLE IS MORE THAN 6FT FROM THE EDGE OF A SINK 48" AFF. DESIGNATED IBC ACCESSIBLE, TYPE A OR B, MAXIMUM HEIGHT TO ANY DEVICE HANDLE SHALL BE 2. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES, OR THOSE DEVICE SO THAT CIRCUITS CAN BE DISCONNECTED SIMULTANEOUSLY. NOTES:1. BREAKERS PROTECTING MULTI-WIRE BRANCH CIRCUITS SHALL BE EQUIPPED WITH A PAD-LOCK 23 SPACE SPACE 24 21 -----SPACE 22 19 15/2 OUTDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 20 17 -----LIGHTS & RECEPTACLES AFCI 15/1 18 15 35/2 INDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 16 13 -----REFRIGERATOR AFCI/GFCI 15/1*14 11 30/2 LOCKOFF WATER HEATER BATHROOM CIRCUIT 20/1 12 9 20/1*AFCI/GFCI MICROWAVE OVEN WASHER AFCI/GFCI 20/1 10 7 -----DISPOSAL AFCI/GFCI 20/1 8 5 30/2 GFCI DRYER DISHWASHER AFCI/GFCI 20/1 6 3 -----KIT/DINING RECEPTACLES AFCI 20/1 4 1 50/2*GFCI RANGE KITCHEN RECEPTACLES AFCI 20/1 2 #POLES TYPE A B TYPE POLES # CKT TRIP /BKR DESCRIPTION PHASE DESCRIPTION BKR TRIP /CKT MAIN:125A MLO VOLTAGE:208/120 PHASE:1 WIRE:3 RECESSED AIC:10,000 LOAD CENTER SCHEDULE - A6 VOLTAGE:208/120 PHASE:1 107.7 AMPS TOTAL 22.4 KVA N.E.C. 220-82 HVAC (HEATING)4.2 KVA X 65 %2.7 KVA HVAC (COOLING)N/A KVA X 100 %KVA HVAC (HEAT PUMP)2.0 KVA X 100 %2.0 KVA REMAINDER 19.2 KVA X 40 %7.7 KVA 1ST 10 KW 10.0 KVA X 100 %10.0 KVA DEMAND FACTOR SUBTOTAL 29.2 KVA WATER HEATERS 4500 VA 4.5 KVA MICROWAVE/HOOD 1500 VA 1.5 KVA DISHWASHERS 1200 VA 1.2 KVA DISPOSALS 800 VA 0.8 KVA REFRIGERAT...1500 VA 1.5 KVA DRYERS 5000 VA 5.0 KVA RANGES 8000 VA 8.0 KVA KITCHEN/LAUNDRY 4500 VA 4.5 KVA SQUARE FOOTAGE 726 SF X 3 VA/SF 2.2 KVA UNIT "A6" J H HH SA SA CACATV TVTVCACASA SAHH H JTVTV TV PANEL 8 8 5 4 3 7 6 1 2 10 WP PANEL 5 3 4 8 8 2 1 6 7 10 WP GENERAL NOTES 1. LOCATION OF SMOKE ALARMS SHALL BE NO LESS THAN 36" FROM A BATHROOM DOOR, SUPPLY AIR REGISTER, OR TIP OF A CEILING FAN BLADE, AND SHALL BE NO LESS THAN 10' FROM A FIXED COOKING APPLIANCE. WHERE WALL MOUNTED, TOP OF DEVICE SHALL BE NO GREATER THAN 12" FROM CEILING. COORDINATE LOCATION WITH SOFFITS AND CROWN MOLDING (WHERE PRESENT). 2. SMOKE AND CO ALARMS SHALL BE WIRED TO AN UNSWITCHED LIGHTING AND RECEPTACLE CIRCUIT. ALARM DEVICES WITHIN A DWELLING UNIT SHALL BE PROVIDED WITH AUXILIARY CONTACTS AND WIRED SO THAT UPON THE ACTIVATION OF ANY ALARM IN THE DWELLING UNIT, ALL SMOKE AND CO ALARMS WITHIN THE DWELLING SHALL SIGNAL AN ALARM. 3. REFER TO "ELECTRICAL DEVICES-DWELLING UNIT KITCHEN" DETAIL INCLUDED IN THESE DRAWINGS FOR DIMENSIONAL INFORMATION OF DEVICES AT CORNERS (WHERE APPLICABLE). 4. ALL 120V, 15-AND 20-AMP RECEPTACLES IN DWELLING UNITS SHALL BE LISTED TAMPER-RESISTANT TYPE. 5. OUTLET BOXES INSTALLED FOR CEILING FANS SHALL BE UL-LISTED "FOR USE WITH CEILING FANS". 6. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR APPLICABLE CIRCUIT REQUIREMENTS. 7. PRIOR TO ROUGH-IN, CONTRACTOR SHALL: • COORDINATE EXACT REQUIREMENTS OF ALL EQUIPMENT AND APPLIANCES FURNISHED BY OTHERS. • COORDINATE LIGHTING FIXTURE LOCATIONS WITH ARCHITECTURAL/INTERIORS DRAWINGS. 8. SEVERAL DWELLING UNIT CIRCUITS AND RECEPTACLES ARE REQUIRED TO BE AFCI- AND/OR GFCI-PROTECTED. REFER TO DRAWINGS AND LOAD CENTER SCHEDULES FOR MORE INFORMATION. 9. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES : • LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS GREATER THAN 48" AFF. • TOGGLE SWITCHES SHALL BE FIELD-INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCHES SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES AND CONTROL THE LIGHTS INDEPENDENT OF THE FAN . 10. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION): • FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM (CAT# 7005-G5), CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE (CAT# 147-10) OUTSIDE OF ENTRY DOOR, TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVING ROOM. • EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. • A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. • REFER TO DETAIL INCLUDED IN THESE DRAWINGS FOR WIRING DIAGRAM OF SMOKE ALARMS AND FIRE ALARM DEVICES. 11. FOR EACH DWELLING UNIT LOCATED AT GRADE-LEVEL OR ON A FLOOR ACCESSIBLE BY ELEVATOR: • LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS GREATER THAN 48"AFF. • FOR ALL DESIGNATED "ANSI TYPE A" UNITS, TOGGLE SWITCHES SHALL BE FIELD-INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCHES SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES AND CONTROL THE LIGHT INDEPENDENT OF THE FAN. 12. UNLESS DIRECTED OTHERWISE, DESIGNATED "ANSI TYPE A" UNITS SHALL HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION): • FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM (CAT# 7005-G5), CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE (CAT# 147-10) OUTSIDE OF ENTRY DOOR, TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVING ROOM. • EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. • A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. • REFER TO DETAIL INCLUDED IN THESE DRAWINGS FOR WIRING DIAGRAM OF SMOKE ALARMS AND FIRE ALARM DEVICES. 13. WHERE APPLICABLE, KITCHEN RECEPTACLE CIRCUIT SHALL POWER GAS COOKTOP IGNITER. 14. RECEPTACLE LAYOUTS SHOWN IN UNITS ARE BASED ON MINIMUM NEC REQUIREMENTS. CONTRACTOR SHALL REVIEW LAYOUTS AND PROVIDE ANY ADDITIONAL RECEPTACLES NEEDED TO BE IN COMPLIANCE WITH NEC BASED ON ACTUAL FIELD INSTALLED LOCATIONS. KEY NOTES (DESIGNATED BY " # ") 1. NEMA 5-20R FOR CLOTHES WASHER. CIRCUIT SHALL BE 2#12, #12G. 2. NEMA 14-30R FOR CLOTHES DRYER. CIRCUIT SHALL BE 3#10, #10G. 3. NEMA 14-50R FOR RANGE/OVEN. CIRCUIT SHALL BE 3#6, #10G. 4. NEMA 5-20R FOR MICROWAVE/EXHAUST HOOD. CIRCUIT SHALL BE 2#12, #12G. LOCATE RECEPTACLE IN CABINETRY ABOVE. RECEPTACLE MAY BE LOCATED BELOW COUNTER IN ACCESSIBLE UNITS. REFER TO ARCHITECTURAL KITCHEN ELEVATIONS FOR FURTHER INFORMATION. 5. FOR SINK DISPOSAL/DISHWASHER CONNECTION, INSTALL SPLIT-WIRED NEMA 5-20R DUPLEX WITHIN BASE CABINET. RECEPTACLE SHALL BE ACCESSIBLE AND LOCATED IN CABINET ADJACENT TO DISHWASHER. DISHWASHER CORD LENGTH SHALL NOT EXCEED 6'-6". 6. DISCONNECT SWITCH FOR AIR-HANDLING UNIT. 7. JUNCTION BOX FOR CONNECTION TO WATER HEATER. CIRCUIT SHALL BE 2#10, 1# 10G. 8. INSTALL RECEPTACLE NO MORE THAN 12" BELOW COUNTERTOP, PROVIDED THAT THE COUNTERTOP EXTENDS NO MORE THAN 6" BEYOND ITS SUPPORT BASE. 9. PROVIDE JUNCTION BOX FOR POWER TO OUTSIDE AIR FAN (OAF), SPEED CONTROLLER AND RELAY PROVIDED BY DIVISION 23.OAF SHALL BE PROVIDED WITH MOTOR RATED DISCONNECT SWITCH AS PART OF THE MECHANICAL SUBMITTAL.CONTRACTOR SHALL COORDINATE AND INSTALL DISCONNECT TO MEET NEC WORKING CLEARANCE REQUIREMENTS.CONNECT TO THE NEAREST LIGHTING & RECEPTACLE CIRCUIT. COORDINATE EXACT REQUIEMENTS WITH THE MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. 10. PROVIDE RECEPTACLE FOR TELECOMMUNICATIONS STRUCTURED MEDIA CENTER PANEL (MP). COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH TELECOM DRAWINGS BEFORE INSTALLATION. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:56:28 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE04.03 IMW MJS 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/4" = 1'-0" UNIT B11 Scale: 1/4" = 1'-0" UNIT B22 RECEPTACLE WOULD FOLLOW MEASURED AS THE SHORTEST PATH THE CORD OF AN APPLIANCE CONNECTED TO THE *GFCI NOT REQUIRED WHERE RECEPTACLE IS MORE THAN 6FT FROM THE EDGE OF A SINK 48" AFF. DESIGNATED IBC ACCESSIBLE, TYPE A OR B, MAXIMUM HEIGHT TO ANY DEVICE HANDLE SHALL BE 2. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES, OR THOSE DEVICE SO THAT CIRCUITS CAN BE DISCONNECTED SIMULTANEOUSLY. NOTES:1. BREAKERS PROTECTING MULTI-WIRE BRANCH CIRCUITS SHALL BE EQUIPPED WITH A PAD-LOCK 23 SPACE SPACE 24 21 -----SPACE 22 19 20/2 OUTDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 20 17 -----LIGHTS & RECEPTACLES AFCI 15/1 18 15 50/2 INDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 16 13 -----REFRIGERATOR AFCI/GFCI 15/1*14 11 30/2 LOCKOFF WATER HEATER BATHROOM CIRCUIT 20/1 12 9 20/1*AFCI/GFCI MICROWAVE OVEN WASHER AFCI/GFCI 20/1 10 7 -----DISPOSAL AFCI/GFCI 20/1 8 5 30/2 GFCI DRYER DISHWASHER AFCI/GFCI 20/1 6 3 -----KIT/DINING RECEPTACLES AFCI 20/1 4 1 50/2*GFCI RANGE KITCHEN RECEPTACLES AFCI 20/1 2 #POLES TYPE A B TYPE POLES # CKT TRIP /BKR DESCRIPTION PHASE DESCRIPTION BKR TRIP /CKT MAIN:125A MLO VOLTAGE:208/120 PHASE:1 WIRE:3 RECESSED AIC:10,000 LOAD CENTER SCHEDULE - B2 VOLTAGE:208/120 PHASE:1 119.0 AMPS TOTAL 24.7 KVA N.E.C. 220-82 HVAC (HEATING)6.4 KVA X 65 %4.2 KVA HVAC (COOLING)N/A KVA X 100 %KVA HVAC (HEAT PUMP)2.5 KVA X 100 %2.5 KVA REMAINDER 20.2 KVA X 40 %8.1 KVA 1ST 10 KW 10.0 KVA X 100 %10.0 KVA DEMAND FACTOR SUBTOTAL 30.2 KVA WATER HEATERS 4500 VA 4.5 KVA MICROWAVE/HOOD 1500 VA 1.5 KVA DISHWASHERS 1200 VA 1.2 KVA DISPOSALS 800 VA 0.8 KVA REFRIGERAT...1500 VA 1.5 KVA DRYERS 5000 VA 5.0 KVA RANGES 8000 VA 8.0 KVA KITCHEN/LAUNDRY 4500 VA 4.5 KVA SQUARE FOOTAGE 1072 SF X 3 VA/SF 3.2 KVA UNIT "B2" RECEPTACLE WOULD FOLLOW MEASURED AS THE SHORTEST PATH THE CORD OF AN APPLIANCE CONNECTED TO THE *GFCI NOT REQUIRED WHERE RECEPTACLE IS MORE THAN 6FT FROM THE EDGE OF A SINK 48" AFF. DESIGNATED IBC ACCESSIBLE, TYPE A OR B, MAXIMUM HEIGHT TO ANY DEVICE HANDLE SHALL BE 2. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES, OR THOSE DEVICE SO THAT CIRCUITS CAN BE DISCONNECTED SIMULTANEOUSLY. NOTES:1. BREAKERS PROTECTING MULTI-WIRE BRANCH CIRCUITS SHALL BE EQUIPPED WITH A PAD-LOCK 23 SPACE SPACE 24 21 -----SPACE 22 19 20/2 OUTDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 20 17 -----LIGHTS & RECEPTACLES AFCI 15/1 18 15 50/2 INDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 16 13 -----REFRIGERATOR AFCI/GFCI 15/1*14 11 30/2 LOCKOFF WATER HEATER BATHROOM CIRCUIT 20/1 12 9 20/1*AFCI/GFCI MICROWAVE OVEN WASHER AFCI/GFCI 20/1 10 7 -----DISPOSAL AFCI/GFCI 20/1 8 5 30/2 GFCI DRYER DISHWASHER AFCI/GFCI 20/1 6 3 -----KIT/DINING RECEPTACLES AFCI 20/1 4 1 50/2*GFCI RANGE KITCHEN RECEPTACLES AFCI 20/1 2 #POLES TYPE A B TYPE POLES # CKT TRIP /BKR DESCRIPTION PHASE DESCRIPTION BKR TRIP /CKT MAIN:125A MLO VOLTAGE:208/120 PHASE:1 WIRE:3 RECESSED AIC:10,000 LOAD CENTER SCHEDULE - B1 VOLTAGE:208/120 PHASE:1 118.8 AMPS TOTAL 24.7 KVA N.E.C. 220-82 HVAC (HEATING)6.4 KVA X 65 %4.2 KVA HVAC (COOLING)N/A KVA X 100 %KVA HVAC (HEAT PUMP)2.5 KVA X 100 %2.5 KVA REMAINDER 20.1 KVA X 40 %8.0 KVA 1ST 10 KW 10.0 KVA X 100 %10.0 KVA DEMAND FACTOR SUBTOTAL 30.1 KVA WATER HEATERS 4500 VA 4.5 KVA MICROWAVE/HOOD 1500 VA 1.5 KVA DISHWASHERS 1200 VA 1.2 KVA DISPOSALS 800 VA 0.8 KVA REFRIGERAT...1500 VA 1.5 KVA DRYERS 5000 VA 5.0 KVA RANGES 8000 VA 8.0 KVA KITCHEN/LAUNDRY 4500 VA 4.5 KVA SQUARE FOOTAGE 1036 SF X 3 VA/SF 3.1 KVA UNIT "B1" JTVTVTVSA SA CACAH HH PANEL WP 1 2 4 3 5 7 6 8 8 10 GENERAL NOTES 1. LOCATION OF SMOKE ALARMS SHALL BE NO LESS THAN 36" FROM A BATHROOM DOOR, SUPPLY AIR REGISTER, OR TIP OF A CEILING FAN BLADE, AND SHALL BE NO LESS THAN 10' FROM A FIXED COOKING APPLIANCE. WHERE WALL MOUNTED, TOP OF DEVICE SHALL BE NO GREATER THAN 12" FROM CEILING. COORDINATE LOCATION WITH SOFFITS AND CROWN MOLDING (WHERE PRESENT). 2. SMOKE AND CO ALARMS SHALL BE WIRED TO AN UNSWITCHED LIGHTING AND RECEPTACLE CIRCUIT. ALARM DEVICES WITHIN A DWELLING UNIT SHALL BE PROVIDED WITH AUXILIARY CONTACTS AND WIRED SO THAT UPON THE ACTIVATION OF ANY ALARM IN THE DWELLING UNIT, ALL SMOKE AND CO ALARMS WITHIN THE DWELLING SHALL SIGNAL AN ALARM. 3. REFER TO "ELECTRICAL DEVICES-DWELLING UNIT KITCHEN" DETAIL INCLUDED IN THESE DRAWINGS FOR DIMENSIONAL INFORMATION OF DEVICES AT CORNERS (WHERE APPLICABLE). 4. ALL 120V, 15-AND 20-AMP RECEPTACLES IN DWELLING UNITS SHALL BE LISTED TAMPER-RESISTANT TYPE. 5. OUTLET BOXES INSTALLED FOR CEILING FANS SHALL BE UL-LISTED "FOR USE WITH CEILING FANS". 6. REFER TO MECHANICAL EQUIPMENT CONNECTION SCHEDULE FOR APPLICABLE CIRCUIT REQUIREMENTS. 7. PRIOR TO ROUGH-IN, CONTRACTOR SHALL: • COORDINATE EXACT REQUIREMENTS OF ALL EQUIPMENT AND APPLIANCES FURNISHED BY OTHERS. • COORDINATE LIGHTING FIXTURE LOCATIONS WITH ARCHITECTURAL/INTERIORS DRAWINGS. 8. SEVERAL DWELLING UNIT CIRCUITS AND RECEPTACLES ARE REQUIRED TO BE AFCI- AND/OR GFCI-PROTECTED. REFER TO DRAWINGS AND LOAD CENTER SCHEDULES FOR MORE INFORMATION. 9. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES : • LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS GREATER THAN 48" AFF. • TOGGLE SWITCHES SHALL BE FIELD-INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCHES SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES AND CONTROL THE LIGHTS INDEPENDENT OF THE FAN . 10. FOR DWELLING UNITS DESIGNATED TO HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION): • FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM (CAT# 7005-G5), CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE (CAT# 147-10) OUTSIDE OF ENTRY DOOR, TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVING ROOM. • EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. • A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. • REFER TO DETAIL INCLUDED IN THESE DRAWINGS FOR WIRING DIAGRAM OF SMOKE ALARMS AND FIRE ALARM DEVICES. 11. FOR EACH DWELLING UNIT LOCATED AT GRADE-LEVEL OR ON A FLOOR ACCESSIBLE BY ELEVATOR: • LOAD CENTER SHALL BE INSTALLED SO THAT NO TRIM LATCH OR BREAKER IS GREATER THAN 48"AFF. • FOR ALL DESIGNATED "ANSI TYPE A" UNITS, TOGGLE SWITCHES SHALL BE FIELD-INSTALLED AND WIRED FOR THE RANGE HOOD/LIGHT CIRCUIT. SWITCHES SHALL BE MOUNTED ABOVE COUNTER WITHIN REQUIRED REACH RANGES AND CONTROL THE LIGHT INDEPENDENT OF THE FAN. 12. UNLESS DIRECTED OTHERWISE, DESIGNATED "ANSI TYPE A" UNITS SHALL HAVE COMMUNICATION FEATURES FOR SENSORY-IMPAIRED (HEARING OR VISION): • FURNISH AND INSTALL AN EDWARDS (OR EQUAL) "DOORBELL" SYSTEM (CAT# 7005-G5), CONSISTING OF A LOW-VOLTAGE TRANSFORMER, PUSHBUTTON AND HORN/STROBE. LOCATE PUSHBUTTON WITH COVERPLATE (CAT# 147-10) OUTSIDE OF ENTRY DOOR, TRANSFORMER CONCEALED WITHIN CLOTHES CLOSET, AND HORN/STROBE WITHIN LIVING ROOM. • EACH FIRE ALARM SYSTEM AUDIBLE APPLIANCE SHALL BE EQUIPPED WITH A VISUAL DEVICE. • A FIRE ALARM VISUAL DEVICE SHALL BE INSTALLED IN EACH BATHROOM. • REFER TO DETAIL INCLUDED IN THESE DRAWINGS FOR WIRING DIAGRAM OF SMOKE ALARMS AND FIRE ALARM DEVICES. 13. WHERE APPLICABLE, KITCHEN RECEPTACLE CIRCUIT SHALL POWER GAS COOKTOP IGNITER. 14. RECEPTACLE LAYOUTS SHOWN IN UNITS ARE BASED ON MINIMUM NEC REQUIREMENTS. CONTRACTOR SHALL REVIEW LAYOUTS AND PROVIDE ANY ADDITIONAL RECEPTACLES NEEDED TO BE IN COMPLIANCE WITH NEC BASED ON ACTUAL FIELD INSTALLED LOCATIONS. KEY NOTES (DESIGNATED BY " # ") 1. NEMA 5-20R FOR CLOTHES WASHER. CIRCUIT SHALL BE 2#12, #12G. 2. NEMA 14-30R FOR CLOTHES DRYER. CIRCUIT SHALL BE 3#10, #10G. 3. NEMA 14-50R FOR RANGE/OVEN. CIRCUIT SHALL BE 3#6, #10G. 4. NEMA 5-20R FOR MICROWAVE/EXHAUST HOOD. CIRCUIT SHALL BE 2#12, #12G. LOCATE RECEPTACLE IN CABINETRY ABOVE. RECEPTACLE MAY BE LOCATED BELOW COUNTER IN ACCESSIBLE UNITS. REFER TO ARCHITECTURAL KITCHEN ELEVATIONS FOR FURTHER INFORMATION. 5. FOR SINK DISPOSAL/DISHWASHER CONNECTION, INSTALL SPLIT-WIRED NEMA 5-20R DUPLEX WITHIN BASE CABINET. RECEPTACLE SHALL BE ACCESSIBLE AND LOCATED IN CABINET ADJACENT TO DISHWASHER. DISHWASHER CORD LENGTH SHALL NOT EXCEED 6'-6". 6. DISCONNECT SWITCH FOR AIR-HANDLING UNIT. 7. JUNCTION BOX FOR CONNECTION TO WATER HEATER. CIRCUIT SHALL BE 2#10, 1# 10G. 8. INSTALL RECEPTACLE NO MORE THAN 12" BELOW COUNTERTOP, PROVIDED THAT THE COUNTERTOP EXTENDS NO MORE THAN 6" BEYOND ITS SUPPORT BASE. 9. PROVIDE JUNCTION BOX FOR POWER TO OUTSIDE AIR FAN (OAF), SPEED CONTROLLER AND RELAY PROVIDED BY DIVISION 23.OAF SHALL BE PROVIDED WITH MOTOR RATED DISCONNECT SWITCH AS PART OF THE MECHANICAL SUBMITTAL.CONTRACTOR SHALL COORDINATE AND INSTALL DISCONNECT TO MEET NEC WORKING CLEARANCE REQUIREMENTS.CONNECT TO THE NEAREST LIGHTING & RECEPTACLE CIRCUIT. COORDINATE EXACT REQUIEMENTS WITH THE MECHANICAL CONTRACTOR PRIOR TO INSTALLATION. 10. PROVIDE RECEPTACLE FOR TELECOMMUNICATIONS STRUCTURED MEDIA CENTER PANEL (MP). COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH TELECOM DRAWINGS BEFORE INSTALLATION. DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:56:33 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE04.04 IMW MJS 2247601 UNIT PLANS SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCIMW MJS Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 1/4" = 1'-0" UNIT BA11 VOLTAGE:208/120 PHASE:1 118.8 AMPS TOTAL 24.7 KVA N.E.C. 220-82 HVAC (HEATING)6.4 KVA X 65 %4.2 KVA HVAC (COOLING)N/A KVA X 100 %KVA HVAC (HEAT PUMP)2.5 KVA X 100 %2.5 KVA REMAINDER 20.1 KVA X 40 %8.1 KVA 1ST 10 KW 10.0 KVA X 100 %10.0 KVA DEMAND FACTOR SUBTOTAL 30.1 KVA WATER HEATERS 4500 VA 4.5 KVA MICROWAVE/HOOD 1500 VA 1.5 KVA DISHWASHERS 1200 VA 1.2 KVA DISPOSALS 800 VA 0.8 KVA REFRIGERAT...1500 VA 1.5 KVA DRYERS 5000 VA 5.0 KVA RANGES 8000 VA 8.0 KVA KITCHEN/LAUNDRY 4500 VA 4.5 KVA SQUARE FOOTAGE 1046 SF X 3 VA/SF 3.1 KVA UNIT "BA1" RECEPTACLE WOULD FOLLOW MEASURED AS THE SHORTEST PATH THE CORD OF AN APPLIANCE CONNECTED TO THE *GFCI NOT REQUIRED WHERE RECEPTACLE IS MORE THAN 6FT FROM THE EDGE OF A SINK 48" AFF. DESIGNATED IBC ACCESSIBLE, TYPE A OR B, MAXIMUM HEIGHT TO ANY DEVICE HANDLE SHALL BE 2. FOR DWELLING UNITS DESIGNATED TO HAVE ACCESSIBLE MOBILITY FEATURES, OR THOSE DEVICE SO THAT CIRCUITS CAN BE DISCONNECTED SIMULTANEOUSLY. NOTES:1. BREAKERS PROTECTING MULTI-WIRE BRANCH CIRCUITS SHALL BE EQUIPPED WITH A PAD-LOCK 23 SPACE SPACE 24 21 -----SPACE 22 19 20/2 OUTDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 20 17 -----LIGHTS & RECEPTACLES AFCI 15/1 18 15 50/2 INDOOR HVAC LIGHTS & RECEPTACLES AFCI 15/1 16 13 -----REFRIGERATOR AFCI/GFCI 15/1*14 11 30/2 LOCKOFF WATER HEATER BATHROOM CIRCUIT 20/1 12 9 20/1*AFCI/GFCI MICROWAVE OVEN WASHER AFCI/GFCI 20/1 10 7 -----DISPOSAL AFCI/GFCI 20/1 8 5 30/2 GFCI DRYER DISHWASHER AFCI/GFCI 20/1 6 3 -----KIT/DINING RECEPTACLES AFCI 20/1 4 1 50/2*GFCI RANGE KITCHEN RECEPTACLES AFCI 20/1 2 #POLES TYPE A B TYPE POLES # CKT TRIP /BKR DESCRIPTION PHASE DESCRIPTION BKR TRIP /CKT MAIN:125A MLO VOLTAGE:208/120 PHASE:1 WIRE:3 RECESSED AIC:10,000 LOAD CENTER SCHEDULE - BA1 T TTT FFFFTFFFFFFFF FFFFFFFFF F FF FF LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 1 LEVEL 2 ROOF LEVEL 6 LEVEL 7 LEVEL 8 LEVEL 9 LEVEL 10 1600A/3/3R 1600A RETAIL TROUGH 400A/3/3R 400A/3/3R METERING AND DISCONNECTS FOR FUTURE RETAIL TENANTS HH T-HL 30 kVA 480V-208/120V HL 400A/3/3R 400A/3/3R MSR1 2500A 208/120V SPD MSR2 2500A 208/120V SPD MSR4 2000A 208/120V SPD MSR3 2500A 208/120V SPD T5 208/120V MC131600A MLO T2 480/277V T3 208/120V T1 480/277V MC25 1200A MLO MC27 1200A MLO MC29 1200A MLO MC35 1200A MLO MC36 1600A MLO 1HES T-1ES 75 kVA 480V-208/120V 1LES1HEL T-1EL 45 kVA 480V-208/120V 1LEL 1DHES 600A ATS-ES 200A ATS-EL 1200A MTS-EL MSC1 3200A 480/277V SPD 1200A/3/3R 1200A RETAIL TROUGH 400A/3/3R METERING AND DISCONNECTS FOR FUTURE RETAIL TENANTS 1000A/3/3R CT CABINET CT CABINET 300 KW GENSET G 600A 200A HHB T-LHB 112.5 kVA 480V-208/120V LHB T-EV 225 kVA 480V-208/120V DPEV MC16 1600A MLO HP13 LP13 MC13 16 UNITS UNITLOAD CENTERS MC1316 UNITS UNIT LOAD CENTERS MC1316 UNITS UNIT LOAD CENTERS MC1616 UNITS UNIT LOAD CENTERS MC1616 UNITS UNIT LOAD CENTERS MC1616 UNITS UNIT LOAD CENTERS MC25 3 UNITS UNITLOAD CENTERS MC253 UNITS UNIT LOAD CENTERS MC253 UNITS UNIT LOAD CENTERS MC2519 UNITS UNIT LOAD CENTERS MC2719 UNITS UNIT LOAD CENTERS MC2719 UNITS UNIT LOAD CENTERS MC2919 UNITS UNIT LOAD CENTERS MC2919 UNITS UNIT LOAD CENTERS MC35 9 UNITS UNITLOAD CENTERS MC359 UNITS UNIT LOAD CENTERS MC359 UNITS UNIT LOAD CENTERS UNIT LOAD CENTERS MC3627 UNITS UNIT LOAD CENTERS UNIT LOAD CENTERS MC4831 UNITS UNIT LOAD CENTERS MC4931 UNITS UNIT LOAD CENTERS MC3627 UNITS MC48 1600A MLO MC49 1200A MLO MC3611 UNITS EH16 EL16 HP25 LP25 EH25 EL25 HP27 LP27 HP29 LP29 EH27 EL27 EH29 EL29 HP49 LP49 EH49 EL49 HP48 LP48 EH48 EL48 HP36 LP36 EH36 EL36 HP35 LP36 EH35 EL35 9 SETS 4 SETS 5 SETS7 SETS T4 208/120V 7 SETS 6 SETS 7 SETS UNIT LOAD CENTERS MC4820 UNITS DRAWN BY CHECKED BY JOB NUMBER: SHEET NAME: THIS DRAWING AND ASSOCIATED DOCUMENTS ARE THE EXCLUSIVE PROPERTY OF DWELL DESIGN STUDIO, AND ARE NOT TO BE REPRODUCED OR COPIED IN WHOLE OR IN PART, EXCEPT AS REQUIRED FOR THE STATED PROJECT. THEY ARE ONLY TO BE USED FOR THIS PROJECT AND SITE SPECIFICALLY IDENTIFIED HEREIN AND ARE NOT TO BE USED ON ANY OTHER PROJECT WITHOUT WRITTEN CONSENT OF DWELL DESIGN STUDIO. SCALES AS NOTED ON THIS DRAWING ARE VALID ON THE ORIGINAL DRAWING ONLY, THE DIMENSIONS OF WHICH ARE 30 x 42 INCHES. DISCLAIMER: SEAL: ISSUE A DEVELOPMENT FOR: REVISION DATE DESCRIPTION INCLUDED 1910 SOUTH BLVD. CHARLOTTE, NC 28203 PHONE: 770.864.1035 dwelldesignstudio.com 22020579 C-2330 11/29/2022 1:56:36 PMD:\Revit Projects\22020579-MCRT Foundry\22020579-MCRT Foundry-E-r22_IsaacW.rvtE05.01 Author Checker 2247601 ELECTRICAL RISER DIAGRAM SCHEMATIC DESIGN PACKAGE 11/30/2022 SCHEMATIC DESIGN PACKAGE MILL CREEK RESIDENTIALTHE FOUNDRY601-622 SOUTH CEDAR ST. CHARLOTTE, NCAuthor Checker Jordan & Skala Engineers 4501 Charlotte Park Dr., ●Suite 100 Charlotte, NC 28217 p. 704.599.4377 ●f. 704.509.9330 Project Number: Drawn By:Checked By: Certification No.: DATE DESCRIPTION REV Scale: 12" = 1'-0" ELECTRICAL ONE-LINE1 !( !( !(!( !(!(!( !<(!<( !(!(!<( !<( !(!( !<( !(!( !<( !(!<( !( !( !( !( !( !<( !( !( !(!( !<(!(!<( !( !( !( !<(!( !<(!( !(!<( !( !<( !( !<( !<( !<( !( !( !( !( !(SS-1 SS-2 SG-1 SS-3 CMW-4B SG-2/A SG-3/A CB SG-5/A SG-4/B C B SG-17/A C TW-3 SG-6/A C SG-7/A B B C A SB-2 SS-4/SB-1MW-1 B C B SG-9/ACSG-16/B C B MW-3 SG-15/A CSG-14/A B C SG-10/A C SG-13/BC SG-12/A SG-11/B SG-8/A MW-2 D D EEEX-9 EX-1 EX-2 EX-3 EX-5 EX-4 EX-10 EX-11 EX-13 EX-12 EX-8 EX-7 EX-0 EX-6 0 200100Feet ^_ ± !(Groundwater Sample !(Soil Gas Sample !(Soil Sample !(Sub-Slab Soil Gas Sample !<(Soil Gas & Soil Sample !<(Sub-Slab Soil Gas & Soil SampleGP-2 Area of Concern (2012) Interior DevelopmentSurface Water Excavation ZoneElevatorStairsBuilding FootprintProperty BoundaryApproximate Excavation Depth (ft)41020 EMP Attachment 2.0Sample Location Map 600 Eldridge StreetCharlotte, North Carolina ProjectManager:JT DrawnBy:EJK CheckedBy:__ Legend: .. -Approximate Location Of Soil Sample Collected By Geoscience $ -Approximate Location Of Geoprobe Boring Attempted By Geoscience -+--Reported Location Of Soil Sample Collected By Other Consultant GP-5 .. 07'~13103 N ·- SCALE: l" = 90' DATE: March 25, 2013 v 0 .o 07318106 . ·-GP-7 -... _ ·- . --:+-s1a109·-· ... (, () 07~ ·~ 0731831"' 605 '"-/ 6J4 I I '· / 0731a3 12 I / 07. 07318313 I 0731 e401 ) I ,,I/ ./ 07318301 608 I ' 07318304 GEOSCIENCE GROUP, INC CHARLOTTE, N TH CAROLINA ./ APPROVED BY: DRAWN BY: Charlotte REVISED: TCH THE FOUNDRY CHARLOTTE, NORTH CAROLINA / ~ SOIL SAMPLE LOCATION DIAGRAM FIGURE NUMBER: CH014-4 December 8, 2023 Sent Via E-mail Welch Liles AP Foundry, LP 1616 Camden Road, Suite 210, Charlotte, NC 28203 iwliles@asanapartners.com Subject: Soil Management Export Dynamic Auto Works II and Foundry Charlotte, Mecklenburg County Brownfields Project Nos 26093-22-060 & 17021-13-060 Dear Mr. Liles, The North Carolina Department of Environmental Quality Brownfields Redevelopment Section (DEQ Brownfields) received and reviewed a request to export approximately 51,000 cubic yards of soil for the planned redeveloped at the above referenced Brownfields Properties. This request was submitted on your behalf in a Soil Export Request letter report dated December 8, 2023prepared by ONE Environmental Group of the Carolinas, PLLC. Based on our review of the data, the DEQ Brownfield agrees that these soils may be exported as outlined in the table below. Other Beneficial Fill and Land Clearing & Inert Debris Landfill (LCID) options may be available; however, DEQ requires that the receiving facility be identified and discussed prior to export. The receiving facility should have metals concentrations which are consistent with those from the Brownfields Properties. LOCATION ID DEPTH (Ft)1 Est. VOLUME (YD3 MANAGEMENT OPTIONS EX-0 0-4 1,200 MSWLF EX-1 0-2 450 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 2-5 675 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 5-10 1,125 Old 27, Griffin Farms, CDLF, MSWLF, TVBF EX-2 0-2 425 Griffin Farms, CDLF, MSWLF, TVBF 2-5 638 Old 27, CDLF, MSWLF, TVBF 5-10 1,063 Old 27, CDLF, MSWLF, TVBF 10-20 2,125 MSWLF, TVBF EX-3 0-2 425 CDLF, MSWLF, TVBF 2-5 638 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 5-10 1,063 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 10-20 2,125 Old 27, CDLF, MSWLF, TVBF LOCATION ID DEPTH (Ft)1 Est. VOLUME (YD3 MANAGEMENT OPTIONS EX-4 0-2 450 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 2-5 675 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 5-10 1,125 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 10-20 2,250 Old 27, Griffin Farms, CDLF, MSWLF, TVBF EX-5 0-2 450 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 2-5 675 MSWLF, TVBF 5-10 1,125 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 10-20 2,250 Old 27, Griffin Farms, CDLF, MSWLF, TVBF EX-6 0-2 400 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 2-5 600 Old 27, CDLF, MSWLF, TVBF 5-10 1,000 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 10-20 2,000 MSWLF, TVBF EX-7 0-2 400 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 2-5 600 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 5-10 1,000 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 10-20 2,000 Old 27, Griffin Farms, CDLF, MSWLF, TVBF EX-8 0-2 433 MSWLF, TVBF 2-5 650 MSWLF, TVBF 5-10 1,082 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 10-18.5 1,838 Old 27, Griffin Farms, CDLF, MSWLF, TVBF EX-9 0-2 600 MSWLF, TVBF 2-5 900 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 5-10 1,500 Old 27, Griffin Farms, CDLF, MSWLF, TVBF EX-10 0-2 450 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 2-5 675 MSWLF, TVBF 5-10 1,125 MSWLF, TVBF EX-11 0-2 450 MSWLF, TVBF 2-5 675 MSWLF, TVBF 5-10 1,125 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 10-20 2,250 Old 27, CDLF, MSWLF, TVBF EX-12 0-2 515 CDLF, MSWLF, TVBF 2-5 772 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 5-10 1,286 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 10-17.5 1,930 Old 27, Griffin Farms, CDLF, MSWLF, TVBF EX-13 0-2 450 CDLF, MSWLF, TVBF 2-5 675 Old 27, Griffin Farms, CDLF, MSWLF, TVBF 5-10 1,125 Old 27, CDLF, MSWLF, TVBF 10-20 2,250 Old 27, Griffin Farms, CDLF, MSWLF, TVBF Notes: 1) Depth listed is total depth of available analytical data. Additional sampling would potentially be required beyond these depths prior to export. 2) Old 27= Old 27 Landfill (36A-LCID) 123 Tate Street, Mount Holly, NC; Griffin Farms = Griffin Farms Landfill (9013-LCID) at 4242 Morgan Mill Road, Unionville, NC; CDLF = Construction & Demolition landfill; MSWLF = Municipal Solid Waste landfill (MSWLF) facility ; TVBF = Tarmac Virginia Brownfields Property at 3934 Raleigh Street, Charlotte, Mecklenburg County. Page 3 of 3 December 8, 2023 DEQ Brownfields understands the redevelopment will be done jointly under one DEQ-approved Environmental Management Plan (EMP) under the development name “The Foundry”. All soil export must be conducted under an approved EMP. Soils should be field screened during excavation prior to export from the property. If unaanticipated impacts are identified during excavation, please refer to the EMP for further actions and cease transfer until appropriate characterization can be completed. In addition, in accordance with the Dynamic Auto II EMP, an annual Redevelopment Summary Report will be submitted to DEQ Brownfields. Details related to the disposition of this soil including but not limited to, total volume, general description of field screening efforts, etc. should be included with the Redevelopment Summary Report. Please be advised that this compliance review from DEQ Brownfields does not waive any applicable requirement to obtain any necessary permits, licenses or certifications which may be required from other state or local entities. If you have any questions, please contact me at (704) 661-10330, or via e-mail at Carolyn.minnich@deq.nc.gov. Sincerely, Carolyn Minnich Project Manager Brownfields Redevelopment Section ec: BFPropertyManagement BFPropertyManagement@deq.nc.gov Mary Katherine Stukes marykatherinestukes@mvalaw.com Laura Boorman Truesdale lauratruesdale@mvalaw.com Tim Marsh tmarsh@mcrtrust.com Justin Houston jhouston@mcrtrust.com Daren Sweeting dsweeting@mcrtrust.com Robert H Nelson rnelson@mcrtrust.com Jenny Tang JTang@oneenv.com Hillary Goodell hgoodell@oneenv.com Dylan Gottlieb dgottlieb@oneenv.com !(!(!(!(Garage51,701 SFLeasing/Lobby5,107 SFBOHRetail17,440 SFRetail2,859 SFRestaurant7,820 SFEldridge StWarner StMorris StS Cedar StW Hill StMW‐1MW‐3MW‐2MW‐40200100Feet^_EMP Attachment 2.3Groundwater (TCE) Analytical Detections±!(Groundwater Monitoring WellExisting BuildingExisting Building to be DemoedProposed DevelopmentProperty BoundaryProjectManager:JPTDrawnBy:EJKCheckedBy:JPT600 Eldridge StreetCharlotte, North CarolinaNotes:All concentrations are reported in µg/L (micrograms per liter).Laboratory analytical results are screened against the North Carolina Department ofEnvironmental Quality (NCDEQ) 15A NCAC 02L .0202 Groundwater Quality Standards (2L) (2022)Bold = Exceedance of regulatory screening levelMW‐1Result 2LTCE 1.01 3MW‐2Result 2LTCE71.53MW‐3Result 2LTCE83.43MW‐4Result 2LTCE 2.63 3 !(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(!(Garage51,701 SFLeasing/Lobby5,107 SFBOHRetail17,440 SFRetail2,859 SFRestaurant7,820 SFSG‐1SG‐2SG‐3SG‐4SG‐5SG‐6SG‐7SG‐8SG‐9SG‐10SG‐11SG‐12SG‐13SG‐14SG‐15SG‐16SG‐17SS‐1SS‐2SS‐3SS‐40200100Feet^_EMP Attachment 2.4Soil Vapor Exceedances±!(Soil Gas Sample!(Sub-Slab Soil Gas SampleExisting Building to be DemoedProposed DevelopmentProperty BoundaryProjectManager:JPTDrawnBy:EJKCheckedBy:JPT600 Eldridge StreetCharlotte, North CarolinaNotes:All concentrations are reported in µg/L (micrograms per liter).Laboratory analytical results are screened against the North Carolina Department ofEnvironmental Quality (NCDEQ) 15A NCAC 02L .0202 Groundwater Quality Standards (2L) (2022)Bold = Exceedance of a regulatory screening levelSS-1 Result SGSLPCE4,0003,500 HI 0.230 1TCR 8.5E-07 1.0E-06Risk CalculationSS-2 Result SGSLHI NA 1TCR NA 1.0E-06No ExceedanceRisk CalculationSS-3 Result SGSLHI 0.024 1TCR 7.0E-08 1.0E-06No ExceedanceRisk CalculationSS-4 Result SGSLHI 0.002 1TCR 6.0E-08 1.0E-06No ExceedanceRisk CalculationSG-14 Result SGSL1,3-Butadiene11041HI 0.130 1TCR 2.8E-06 1.0E-06Risk CalculationSG-1 Result SGSLTCE660180HI 0.860 1TCR 3.0E-06 1.0E-06Risk CalculationSG-4 Result SGSLHI 0.046 1TCR 5.2E-07 1.0E-06No ExceedanceRisk CalculationSG-5 Result SGSLHI 0.041 1TCR 4.7E-07 1.0E-06No ExceedanceRisk CalculationSG-6 Result SGSLHI 0.006 1TCR 1.4E-07 1.0E-06No ExceedanceRisk CalculationSG-7 Result SGSLHI 0.005 1TCR 8.9E-08 1.0E-06No ExceedanceRisk CalculationSG-8 Result SGSLHI 0.009 1TCR 1.8E-07 1.0E-06No ExceedanceRisk CalculationSG-9 Result SGSLHI 0.013 1TCR 4.6E-08 1.0E-06Risk CalculationNo ExceedanceSG-10 Result SGSLTCE650180HI 0.750 1TCR 2.3E-06 1.0E-06Risk CalculationSG-11 Result SGSLTCE520180HI 0.640 1TCR 2.1E-06 1.0E-06Risk CalculationSG-12 Result SGSLHI 0.008 1TCR 4.3E-08 1.0E-06Risk CalculationNo ExceedanceSG-13 Result SGSLTCE3100180HI 3.700 1TCR 1.1E-05 1.0E-06Risk CalculationSG-15 Result SGSLHI 0.020 1TCR 3.5E-07 1.0E-06No ExceedanceRisk CalculationSG-16 Result SGSLHI 0.009 1TCR 4.5E-08 1.0E-06No ExceedanceRisk CalculationSG-17 Result SGSLHI 0.001 1TCR 2.4E-08 1.0E-06No ExceedanceRisk CalculationSG-2 Result SGSL1,3-Butadiene9041HI 0.110 1TCR 2.3E-06 1.0E-06Risk CalculationSG-3 Result SGSLHI 0.001 1TCR 3.4E-08 1.0E-06No ExceedanceRisk Calculation ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !! ! ! ! ! !! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! !!Eldridge StS Cedar StMo r r i s S t Warner StW H i l l S t -4 -4 -20 -20 -4 -4 -20 -20 -20 -20 -20 -17.5 -10 -20 -17.5 -10 -10 -10 -18.5 -20 -18.5 -18.5 -18.5 -18.5 -10 -10 -10 -17.5-17.5 -20-20 -20 -20 -20 -20 -20 -20-10 -10 -20 -20-17.5 -20 -20-20 -20 -10 -10 -20 -20 -20 -10-10 -4 0 200100Feet ^_ ±Building FootprintExcavation ZoneProperty Boundary Excavation Depth (ft)20 4 EMP Attachment 3.0Cut-Fill Analysis Map 600 Eldridge StreetCharlotte, North Carolina ProjectManager:JT DrawnBy:EJK CheckedBy:__ -20 -20 -10 -20 *All soil excavation depths are approximate. Soil excavation and export are the only activities anticipated on-site.Import of fill material on-site is not anticipated. STST STSTSTSTGASGASGASGASGASGASGASGASGASGASSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTWWWWWWWWWWWWW WWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWWWST 20'SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXS T S T STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSTST663664677665665665670665664665670675675680685690695670675680685690695700675670670670675680690695700705710710705705704700695 690 685680675670 665670675665WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS GAS GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSXXXXXXXXXXXXXXXXXXXXXXXXXUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPSOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EC PH 1N/AC3-006/28/2023 3:37 PM ERIC LEACH P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_EROS1.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658LAND DEVELOPMENT1ST SUBMITTAL04.28.20231LAND DEVELOPMENT2nd SUBMITTAL06.28.20232 1" = 20'4020#10EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING PLAZATOTAL DENUDED AREA:4.40 ACRESEROSION CONTROL NOTES:1.CONTRACTOR TO PROVIDE AS MUCH SPACE AS POSSIBLE BETWEEN TOE OF FILLSLOPE AND SILT FENCE.2.PLEASE CONTACT CITY INSPECTOR TO ADVISE ON START DATE AND SCHEDULEPRE-CONSTRUCTION MEETING.3.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROMTHE ZONING ADMINISTRATOR.4.ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION SHOWN ON THIS PLAN ISSUBJECT TO A FINE.5.GRADING 1 ACRE OR MORE WITHOUT AN APPROVED EROSION CONTROL PLAN IS AVIOLATION AND SUBJECT TO A FINE.6.ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 7 CALENDAR DAYS.7.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIREDBY THE EROSION CONTROL COORDINATOR.8.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. FILL SLOPES GREATER THAN10' REQUIRE ADEQUATE TERRACING. SLOPES GREATER THAN 3:1 SHALL RECEIVEMATTING.9.ALL ELEVATIONS ARE IN REFERENCE TO THE SURVEYORS BENCHMARK WHICHMUST BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING.10.ALL CONSTRUCTION TRAFFIC MUST BE THROUGH THE CONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLAN.11.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE N.C.EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.12.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULDBE CONSTRUCTED AT 3:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENTSLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND ASINDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTEMATERIAL IS HAULED FROM THE PROPERTY THEN THE CONTRACTOR SHALLDISCLOSE THE LOCATION OF ANY ON-SITE AND/OR OFF-SITE BORROW LOCATIONAND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR.BORROW AND WASTE SITES MUST HAVE APPROVE EROSION CONTROL PLAN.13.LIMITS OF CLEARING SHOWN ARE BASED ON CUT AND FILL SLOPES OR OTHERGRADING REQUIREMENTS.14.CONTRACTOR SHALL INSTALL ALL EROSION CONTROL MEASURES AS INDICATEDPRIOR TO GRADING OPERATIONS. NO DEVICE MAY BE REMOVED WITHOUTAPPROVAL OF EROSION CONTROL COORDINATOR.15.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTINGCONTOURS.16.ALL DISTANCES ARE HORIZONTAL GROUND.17.ANCHOR SILT FENCE WITH STONE ON TREE PROTECTION ZONES. DO NOT BURY.18.INLET PROTECTION IS REQUIRED FOR ALL INLETS LOCATED IN THE WORKING AREA19.INLET PROTECTION IS REQUIRED FOR ALL PHASES OF THE PROJECT AND UNTILTHE DISTURBED AREA IS FULLY STABILIZED.20.SEDIMENT TRAP AND BASIN SLOPES SHALL BE STABILIZED AND SEEDEDIMMEDIATELY AFTER CONSTRUCTION.21.CONTRACTOR TO REPLACE ALL STAGING AND STOCKPILE AREAS TO PRECONSTRUCTION CONDITIONS. PROVIDE PHOTO DOCUMENTATION OFPRE-CONSTRUCTION CONDITION AT THESE AREASLIMITS OF DISTURBANCELEGENDLDLDTEMPORARY SILT FENCE (CLDS 30.06A)PROPOSED BAFFLESPROPERTY LINEPROPOSED STABILIZED CONSTRUCTIONENTRANCE (CLDS 30.11A)INLET PROTECTIONPROP. 12" PVC (TYP.)PROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)EX. STORMWATER (TYP.)PROP. PROJECTLIMITS (TYP.)PROP. SILT FENCE(TYP.)EX. SANITARYSEWER (TYP.)EX. STORMWATER (TYP.)PROPERTY LINEPROPERTY LINEPH 1 DISTURBED AREATOTAL = 31,000SF0.71ACPH 1 DISTURBED AREATOTAL = 31,000SF0.71ACPH 1 DISTURBED AREATOTAL = 31,000SF0.71ACPROP. PH 1PROJECT LIMITS(TYP.)PROP. PROJECTLIMITS (TYP.)PH 1 AREA:0.71 ACRESPROP. HIGH HAZARDSILT FENCECOORDINATE WITH STREAMIMPACT PERMITTINGALL CONSTRUCTION TRAFFICMUST BE THROUGH THECONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLANCONSTRUCTION SEQUENCE1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE CITY OFCHARLOTTE ENGINEERING DEPARTMENT.2.FLAG THE CONSTRUCTION LIMITS AND MARK ANY TREES, WETLANDS, OR EXISTINGSTRUCTURES NOTED TO REMAIN.3.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH EROSION CONTROLINSPECTOR OF THE CITY ENGINEERING DEPARTMENT TO DISCUSS EROSIONCONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS PRIORTO ANY LAND-DISTURBING ACTIVITY IS A VIOLATION OF THE CITY CODE AND ISSUBJECT TO FINE.4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE.PHASE 15.INSTALL BOX CULVERT BY-PASSPHASE 26.INSTALL ALL TEMPORARY SILT FENCE, TREE PROTECTION, AND ANY OTHERTEMPORARY MEASURES AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.7.INSTALL SKIMMER SEDIMENT BASIN, CHECK DAMS AND DIVERSION DITCHES.8.CALL FOR ON-SITE INSPECTION BY EROSION CONTROL INSPECTOR. WHENAPPROVED, INSPECTOR WILL ISSUE THE GRADING PERMIT AND CLEARING,GRUBBING AND DEMOLITION MAY BEGIN.9.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES ARE INPLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS.10.BEGIN CLEARING, GRUBBING AND DEMOLITION OPERATIONS. CLEARING ANDGRUBBING SHALL BE DONE ONLY IN AREAS WHERE EARTHWORK WILL BEPERFORMED AND ONLY IN AREAS WHERE CONSTRUCTION IS PLANNED TOCOMMENCE WITHIN 14 DAYS AFTER CLEARING AND GRUBBING.11.BEGIN MASS GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURES ASINDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.12.COMPLETE STABILIZATION OF UPPER SITE, 1.60 ACPHASE 2A13.COORDINATE PHASING OUT OF SED BASIN WITH UNDERGROUND VAULTCONSTRUCTION AND SITE INSPECTOR.14.SED BASIN IS REQUIRED TO BE IN PLACE IF GREATER THAN 1.0 AC OF DISTURBEDAREA ARE PRESENTPHASE 315.IN COORDINATION WITH SITE INSPECTOR UNDERGROUND VAULT TO ACT ASSEDIMENT BASIN.16.MAJORITY OF BUILDING FOOTPRINT TO BE STABILIZED IN THIS PHASEPHASE 417.CONTINUE MAINTENANCE OOF EROSION CONTROL MEASURES18.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING ISNECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS ANDESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTIONSEQUENCE.19.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED AND WITH APPROVALFROM EROSION CONTROL INSPECTOR.20.ALL EROSION CONTROL DEVICES SHOULD BE MONITORED ONCE A WEEK AND AFTEREVERY 1" RAIN EVENT OR GREATER BY A CERTIFIED INSPECTOR. IF ANY FAILURESARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE.21.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITHTHE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S.DEPT. OF AGRICULTURE, CITY OF CHARLOTTE, EROSION CONTROL ORDINANCE, ANDTHE CHARLOTTE LAND DEVELOPMENT STANDARDS.22.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENTPROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSIONMUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.23.UPON STABILIZATION OF ALL UPSTREAM AREA, SKIMMER SEDIMENT VAULT TO BEMUCKED OUT AND CONVERTED TO UNDERGROUND DETENTION. STST STSTSTSTGASGASGASGASGASGASGASGASGASGASSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTWWWWWWWWWWWWW WWW W WWWWWWWWWWWWWWWW WWWWWWWWWWWWST 20'SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTS T STSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSSSTST663664677665665665670665664665670675675680685690695670675680685690695700675670670670675680690695700705710710705704700695 690 685680675670 665670675665WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS GAS GASGASSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSXXXXXXXXXXXXXXXXXXXXXXXXUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPSOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDTD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->675680670661665670675661663665670 6656656.429.0010.00 13.0011.7810.00 10.00 10.005.50LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDMODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EC PH 2N/AC3-026/28/2023 3:37 PM ERIC LEACH P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_EROS2.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658LAND DEVELOPMENT1ST SUBMITTAL04.28.20231LAND DEVELOPMENT2nd SUBMITTAL06.28.20232 1" = 20'4020#10EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING PLAZAEROSION CONTROL NOTES:1.CONTRACTOR TO PROVIDE AS MUCH SPACE AS POSSIBLE BETWEEN TOE OF FILLSLOPE AND SILT FENCE.2.PLEASE CONTACT CITY INSPECTOR TO ADVISE ON START DATE AND SCHEDULEPRE-CONSTRUCTION MEETING.3.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROMTHE ZONING ADMINISTRATOR.4.ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION SHOWN ON THIS PLAN ISSUBJECT TO A FINE.5.GRADING 1 ACRE OR MORE WITHOUT AN APPROVED EROSION CONTROL PLAN IS AVIOLATION AND SUBJECT TO A FINE.6.ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 7 CALENDAR DAYS.7.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIREDBY THE EROSION CONTROL COORDINATOR.8.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. FILL SLOPES GREATER THAN10' REQUIRE ADEQUATE TERRACING. SLOPES GREATER THAN 3:1 SHALL RECEIVEMATTING.9.ALL ELEVATIONS ARE IN REFERENCE TO THE SURVEYORS BENCHMARK WHICHMUST BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING.10.ALL CONSTRUCTION TRAFFIC MUST BE THROUGH THE CONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLAN.11.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE N.C.EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.12.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULDBE CONSTRUCTED AT 3:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENTSLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND ASINDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTEMATERIAL IS HAULED FROM THE PROPERTY THEN THE CONTRACTOR SHALLDISCLOSE THE LOCATION OF ANY ON-SITE AND/OR OFF-SITE BORROW LOCATIONAND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR.BORROW AND WASTE SITES MUST HAVE APPROVE EROSION CONTROL PLAN.13.LIMITS OF CLEARING SHOWN ARE BASED ON CUT AND FILL SLOPES OR OTHERGRADING REQUIREMENTS.14.CONTRACTOR SHALL INSTALL ALL EROSION CONTROL MEASURES AS INDICATEDPRIOR TO GRADING OPERATIONS. NO DEVICE MAY BE REMOVED WITHOUTAPPROVAL OF EROSION CONTROL COORDINATOR.15.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTINGCONTOURS.16.ALL DISTANCES ARE HORIZONTAL GROUND.17.ANCHOR SILT FENCE WITH STONE ON TREE PROTECTION ZONES. DO NOT BURY.18.INLET PROTECTION IS REQUIRED FOR ALL INLETS LOCATED IN THE WORKING AREA19.INLET PROTECTION IS REQUIRED FOR ALL PHASES OF THE PROJECT AND UNTILTHE DISTURBED AREA IS FULLY STABILIZED.20.SEDIMENT TRAP AND BASIN SLOPES SHALL BE STABILIZED AND SEEDEDIMMEDIATELY AFTER CONSTRUCTION.21.CONTRACTOR TO REPLACE ALL STAGING AND STOCKPILE AREAS TO PRECONSTRUCTION CONDITIONS. PROVIDE PHOTO DOCUMENTATION OFPRE-CONSTRUCTION CONDITION AT THESE AREASLIMITS OF DISTURBANCELEGENDLDLDTEMPORARY SILT FENCE (CLDS 30.06A)PROPOSED BAFFLESPROPERTY LINEPROPOSED STABILIZED CONSTRUCTIONENTRANCE (CLDS 30.11A)INLET PROTECTIONPHASE 2SKIMMER SEDIMENT BASIN (SSB 1)DRAINAGE AREA : 3.68 ACSURFACE AREA REQUIRED: 7,987 SFSURFACE AREA PROVIDED: 8,115 SFVOLUME REQUIRED: 6,624 CFVOLUME PROVIDED: 16,900 CFBOTTOM OF BASIN: 661'SURFACE: 663.5'SKIMMER: 662'SPILLWAY: 634'SIDE SLOPE: 3:1PROP. SKIMMER DEWATERINGDEVICESKIMMER SIZE: 3.00"ORIFICE DIAMETER: 2.50"SKIMMER INVERT: 661.00'DE-WATERING TIME: 2.34 DAYSPROP. BAFFLESPROP. 12" PVC TO TIEINTO EX. STORM INLETPROP. 12" PVC (TYP.)PROP. SLOPE DRAINPIPE (TYP.)EX. STORMWATER TO BEREMOVEDEX. SANITARYSEWER (TYP.)EX. STORMWATER (TYP.)PROP. TEMPORARY DIVERSIONDITCH WITH ROCK CHECK DAMSEVERY 50 LF (TYP.)ADJUST PROP. TEMPORARYDIVERSION DITCH AS BUILDINGPROGRESSES. ROCK CHECKDAMS EVERY 50 LF (TYP.)DRAINAGE AREAPROPERTY LINEPROPERTY LINETOTAL DENUDED AREA:4.16 ACRESPH 2 AREA:2.59 ACRESPROP. PROJECTLIMITS (TYP.)PROP. SILT FENCE(TYP.)PH 2 DISTURBED AREATOTAL = 113,000SF2.59ACPROP. PROJECTLIMITS (TYP.)PH 2 STABILIZED:1.59 ACRESREMAINING DENUDED:2.57 ACRESPH 2A DRAINAGE AREA1.49AC TO VAULT.1.59 ACRES OF BUILDINGPAD TO BE STABILIZEDBEFORE SED BASIN ISREMOVED AND FLOWDIVERTED TO VAULT0.38 AC TO STONE OUTLETROCK CHECK DAMS EVERY50 LF (TYP.)COORDINATE WITH STREAMIMPACT PERMITTINGALL CONSTRUCTION TRAFFIC MUST BETHROUGH THE CONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLANSPROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)DITCH 1DITCH 2STABILIZE BASIN SLOPES PERCLDSM STD. 30.00 ON C3-06DITCH 3CONSTRUCTION SEQUENCE1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE CITY OFCHARLOTTE ENGINEERING DEPARTMENT.2.FLAG THE CONSTRUCTION LIMITS AND MARK ANY TREES, WETLANDS, OR EXISTINGSTRUCTURES NOTED TO REMAIN.3.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH EROSION CONTROLINSPECTOR OF THE CITY ENGINEERING DEPARTMENT TO DISCUSS EROSIONCONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS PRIORTO ANY LAND-DISTURBING ACTIVITY IS A VIOLATION OF THE CITY CODE AND ISSUBJECT TO FINE.4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE.PHASE 15.INSTALL BOX CULVERT BY-PASSPHASE 26.INSTALL ALL TEMPORARY SILT FENCE, TREE PROTECTION, AND ANY OTHERTEMPORARY MEASURES AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.7.INSTALL SKIMMER SEDIMENT BASIN, CHECK DAMS AND DIVERSION DITCHES.8.CALL FOR ON-SITE INSPECTION BY EROSION CONTROL INSPECTOR. WHENAPPROVED, INSPECTOR WILL ISSUE THE GRADING PERMIT AND CLEARING,GRUBBING AND DEMOLITION MAY BEGIN.9.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES ARE INPLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS.10.BEGIN CLEARING, GRUBBING AND DEMOLITION OPERATIONS. CLEARING ANDGRUBBING SHALL BE DONE ONLY IN AREAS WHERE EARTHWORK WILL BEPERFORMED AND ONLY IN AREAS WHERE CONSTRUCTION IS PLANNED TOCOMMENCE WITHIN 14 DAYS AFTER CLEARING AND GRUBBING.11.BEGIN MASS GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURES ASINDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.12.COMPLETE STABILIZATION OF UPPER SITE, 1.60 ACPHASE 2A13.COORDINATE PHASING OUT OF SED BASIN WITH UNDERGROUND VAULTCONSTRUCTION AND SITE INSPECTOR.14.SED BASIN IS REQUIRED TO BE IN PLACE IF GREATER THAN 1.0 AC OF DISTURBEDAREA ARE PRESENTPHASE 315.IN COORDINATION WITH SITE INSPECTOR UNDERGROUND VAULT TO ACT ASSEDIMENT BASIN.16.MAJORITY OF BUILDING FOOTPRINT TO BE STABILIZED IN THIS PHASEPHASE 417.CONTINUE MAINTENANCE OOF EROSION CONTROL MEASURES18.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING ISNECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS ANDESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTIONSEQUENCE.19.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED AND WITH APPROVALFROM EROSION CONTROL INSPECTOR.20.ALL EROSION CONTROL DEVICES SHOULD BE MONITORED ONCE A WEEK AND AFTEREVERY 1" RAIN EVENT OR GREATER BY A CERTIFIED INSPECTOR. IF ANY FAILURESARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE.21.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITHTHE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S.DEPT. OF AGRICULTURE, CITY OF CHARLOTTE, EROSION CONTROL ORDINANCE, ANDTHE CHARLOTTE LAND DEVELOPMENT STANDARDS.22.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENTPROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSIONMUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.23.UPON STABILIZATION OF ALL UPSTREAM AREA, SKIMMER SEDIMENT VAULT TO BEMUCKED OUT AND CONVERTED TO UNDERGROUND DETENTION.DITCH 1 0+000+501+001+502+002+500+ 0 01+002+003+003+980+001+001+650+001+002+003+004+004+15STSTSTSTGASGASGASGASGASGASGASGASGASGASWWWWWWWWWWWWW WWW W WWWWWWWWWWWWWWWW WWWWWWWWWWWWSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSS663664677665665665670665664665670675675680685690695670675680685690695700675670670670675680690695700705710710705704700695 690 685680675670 665670675665WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS GAS GASGASSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSXXXXXXXXXXXXXXXXXXXXXXXXUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPSOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDTD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->675680670661665670675661663665670 665TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->DI - 2AD - 1SDMH - 1S-35AD - 3AD - 4AD - 5S-33S-39S-9S-12S-10S-48DI-64DI-65DI-66DI-63AD-62AD-61AD-60AD-59AD-58AD - 2AD-556656.429.0010.00 13.0011.7810.00 10.00 10.005.50LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDMODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EC PH 2AN/AC3-036/28/2023 3:37 PM ERIC LEACH P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_EROS2.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658LAND DEVELOPMENT1ST SUBMITTAL04.28.20231LAND DEVELOPMENT2nd SUBMITTAL06.28.20232 1" = 20'4020#10EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING PLAZAEROSION CONTROL NOTES:1.CONTRACTOR TO PROVIDE AS MUCH SPACE AS POSSIBLE BETWEEN TOE OF FILLSLOPE AND SILT FENCE.2.PLEASE CONTACT CITY INSPECTOR TO ADVISE ON START DATE AND SCHEDULEPRE-CONSTRUCTION MEETING.3.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROMTHE ZONING ADMINISTRATOR.4.ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION SHOWN ON THIS PLAN ISSUBJECT TO A FINE.5.GRADING 1 ACRE OR MORE WITHOUT AN APPROVED EROSION CONTROL PLAN IS AVIOLATION AND SUBJECT TO A FINE.6.ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 7 CALENDAR DAYS.7.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIREDBY THE EROSION CONTROL COORDINATOR.8.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. FILL SLOPES GREATER THAN10' REQUIRE ADEQUATE TERRACING. SLOPES GREATER THAN 3:1 SHALL RECEIVEMATTING.9.ALL ELEVATIONS ARE IN REFERENCE TO THE SURVEYORS BENCHMARK WHICHMUST BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING.10.ALL CONSTRUCTION TRAFFIC MUST BE THROUGH THE CONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLAN.11.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE N.C.EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.12.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULDBE CONSTRUCTED AT 3:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENTSLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND ASINDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTEMATERIAL IS HAULED FROM THE PROPERTY THEN THE CONTRACTOR SHALLDISCLOSE THE LOCATION OF ANY ON-SITE AND/OR OFF-SITE BORROW LOCATIONAND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR.BORROW AND WASTE SITES MUST HAVE APPROVE EROSION CONTROL PLAN.13.LIMITS OF CLEARING SHOWN ARE BASED ON CUT AND FILL SLOPES OR OTHERGRADING REQUIREMENTS.14.CONTRACTOR SHALL INSTALL ALL EROSION CONTROL MEASURES AS INDICATEDPRIOR TO GRADING OPERATIONS. NO DEVICE MAY BE REMOVED WITHOUTAPPROVAL OF EROSION CONTROL COORDINATOR.15.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTINGCONTOURS.16.ALL DISTANCES ARE HORIZONTAL GROUND.17.ANCHOR SILT FENCE WITH STONE ON TREE PROTECTION ZONES. DO NOT BURY.18.INLET PROTECTION IS REQUIRED FOR ALL INLETS LOCATED IN THE WORKING AREA19.INLET PROTECTION IS REQUIRED FOR ALL PHASES OF THE PROJECT AND UNTILTHE DISTURBED AREA IS FULLY STABILIZED.20.SEDIMENT TRAP AND BASIN SLOPES SHALL BE STABILIZED AND SEEDEDIMMEDIATELY AFTER CONSTRUCTION.21.CONTRACTOR TO REPLACE ALL STAGING AND STOCKPILE AREAS TO PRECONSTRUCTION CONDITIONS. PROVIDE PHOTO DOCUMENTATION OFPRE-CONSTRUCTION CONDITION AT THESE AREASLIMITS OF DISTURBANCELEGENDLDLDTEMPORARY SILT FENCE (CLDS 30.06A)PROPOSED BAFFLESPROPERTY LINEPROPOSED STABILIZED CONSTRUCTIONENTRANCE (CLDS 30.11A)INLET PROTECTIONPHASE 2ASKIMMER VAULTDRAINAGE AREA : 1.49 ACSURFACE AREA REQUIRED: 3,234 SFSURFACE AREA PROVIDED: 4,000 SFVOLUME PROVIDED: 10,000 CFBOTTOM OF BASIN: 654'SIDE SLOPE: N/APROP. SKIMMER DEWATERINGDEVICESKIMMER SIZE: 3.00"ORIFICE DIAMETER: 2.00"SKIMMER INVERT: 654.00'DE-WATERING TIME: 2.16 DAYSPROP. 12" PVC TO TIEINTO EX. STORM INLETPROP. 12" PVC (TYP.)EX. SANITARYSEWER (TYP.)EX. STORMWATER (TYP.)PROP. TEMPORARY DIVERSIONDITCH WITH ROCK CHECK DAMSEVERY 50 LF (TYP.)ADJUST PROP. TEMPORARYDIVERSION DITCH AS BUILDINGPROGRESSES. ROCK CHECKDAMS EVERY 50 LF (TYP.)DRAINAGE AREAPROPERTY LINEPROPERTY LINETOTAL DENUDED AREA:4.16 ACRESPH 2 AREA:2.59 ACRESPROP. PROJECTLIMITS (TYP.)PROP. SILT FENCE(TYP.)PROP. PROJECTLIMITS (TYP.)PH 2 STABILIZED:1.59 ACRESREMAINING DENUDED:2.57 ACRESPH 2A DRAINAGE AREA1.49AC TO VAULT.1.59 ACRES OF BUILDINGPAD TO BE STABILIZEDBEFORE SED BASIN ISREMOVED AND FLOWDIVERTED TO VAULT0.38 AC TO STONE OUTLETROCK CHECK DAMS EVERY50 LF (TYP.)ROUTE PH2A TEMPORARYDIVERSION DITCHES TOSEDIMENT VAULT. ROCK CHECKDAMS EVERY 50 LF (TYP.)PROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)ALL CONSTRUCTION TRAFFIC MUST BETHROUGH THE CONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLANSDITCH 2DITCH 1DITCH 4CONSTRUCTION SEQUENCE1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE CITY OFCHARLOTTE ENGINEERING DEPARTMENT.2.FLAG THE CONSTRUCTION LIMITS AND MARK ANY TREES, WETLANDS, OR EXISTINGSTRUCTURES NOTED TO REMAIN.3.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH EROSION CONTROLINSPECTOR OF THE CITY ENGINEERING DEPARTMENT TO DISCUSS EROSIONCONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS PRIORTO ANY LAND-DISTURBING ACTIVITY IS A VIOLATION OF THE CITY CODE AND ISSUBJECT TO FINE.4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE.PHASE 15.INSTALL BOX CULVERT BY-PASSPHASE 26.INSTALL ALL TEMPORARY SILT FENCE, TREE PROTECTION, AND ANY OTHERTEMPORARY MEASURES AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.7.INSTALL SKIMMER SEDIMENT BASIN, CHECK DAMS AND DIVERSION DITCHES.8.CALL FOR ON-SITE INSPECTION BY EROSION CONTROL INSPECTOR. WHENAPPROVED, INSPECTOR WILL ISSUE THE GRADING PERMIT AND CLEARING,GRUBBING AND DEMOLITION MAY BEGIN.9.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES ARE INPLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS.10.BEGIN CLEARING, GRUBBING AND DEMOLITION OPERATIONS. CLEARING ANDGRUBBING SHALL BE DONE ONLY IN AREAS WHERE EARTHWORK WILL BEPERFORMED AND ONLY IN AREAS WHERE CONSTRUCTION IS PLANNED TOCOMMENCE WITHIN 14 DAYS AFTER CLEARING AND GRUBBING.11.BEGIN MASS GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURES ASINDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.12.COMPLETE STABILIZATION OF UPPER SITE, 1.60 ACPHASE 2A13.COORDINATE PHASING OUT OF SED BASIN WITH UNDERGROUND VAULTCONSTRUCTION AND SITE INSPECTOR.14.SED BASIN IS REQUIRED TO BE IN PLACE IF GREATER THAN 1.0 AC OF DISTURBEDAREA ARE PRESENTPHASE 315.IN COORDINATION WITH SITE INSPECTOR UNDERGROUND VAULT TO ACT ASSEDIMENT BASIN.16.MAJORITY OF BUILDING FOOTPRINT TO BE STABILIZED IN THIS PHASEPHASE 417.CONTINUE MAINTENANCE OOF EROSION CONTROL MEASURES18.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING ISNECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS ANDESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTIONSEQUENCE.19.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED AND WITH APPROVALFROM EROSION CONTROL INSPECTOR.20.ALL EROSION CONTROL DEVICES SHOULD BE MONITORED ONCE A WEEK AND AFTEREVERY 1" RAIN EVENT OR GREATER BY A CERTIFIED INSPECTOR. IF ANY FAILURESARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE.21.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITHTHE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S.DEPT. OF AGRICULTURE, CITY OF CHARLOTTE, EROSION CONTROL ORDINANCE, ANDTHE CHARLOTTE LAND DEVELOPMENT STANDARDS.22.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENTPROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSIONMUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.23.UPON STABILIZATION OF ALL UPSTREAM AREA, SKIMMER SEDIMENT VAULT TO BEMUCKED OUT AND CONVERTED TO UNDERGROUND DETENTION.PROP. 24" PVC PIPETOP ELEV: 656.00DITCH 1 STSTSTSTGASGASGASGASGASGASGASGASGASGASWWWWWWWWWWWWW WWW W WWWWWWWWWWWWWWWW WWWWWWWWWWWWSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSS663664677665665665670665664665670675675680685690695670675680685690695700675670670670675680690695700705710710705704700695 690 685680675670 665670675665WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS GAS GASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSXXXXXXXXXXXXXXXXXXXXXXXXUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGP0+000+400+801+201+60SOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)670675680685690688686683678673668695697709708707695665664663664665680679678683684685686687688689690691692693694695696697698699700701702703704704 707708707705 699698696694693692691689687684682681679677676674672671669667682681706704703702704703702701706710705TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->TD->LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDTD->TD->TD->TD->TD->TD->MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EC PH 3N/AC3-046/28/2023 3:37 PM ERIC LEACH P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_EROS3.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658LAND DEVELOPMENT1ST SUBMITTAL04.28.20231LAND DEVELOPMENT2nd SUBMITTAL06.28.20232 1" = 20'4020#10EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGEXISTING PLAZAEROSION CONTROL NOTES:1.CONTRACTOR TO PROVIDE AS MUCH SPACE AS POSSIBLE BETWEEN TOE OF FILLSLOPE AND SILT FENCE.2.PLEASE CONTACT CITY INSPECTOR TO ADVISE ON START DATE AND SCHEDULEPRE-CONSTRUCTION MEETING.3.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROMTHE ZONING ADMINISTRATOR.4.ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION SHOWN ON THIS PLAN ISSUBJECT TO A FINE.5.GRADING 1 ACRE OR MORE WITHOUT AN APPROVED EROSION CONTROL PLAN IS AVIOLATION AND SUBJECT TO A FINE.6.ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 7 CALENDAR DAYS.7.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIREDBY THE EROSION CONTROL COORDINATOR.8.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. FILL SLOPES GREATER THAN10' REQUIRE ADEQUATE TERRACING. SLOPES GREATER THAN 3:1 SHALL RECEIVEMATTING.9.ALL ELEVATIONS ARE IN REFERENCE TO THE SURVEYORS BENCHMARK WHICHMUST BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING.10.ALL CONSTRUCTION TRAFFIC MUST BE THROUGH THE CONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLAN.11.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE N.C.EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.12.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULDBE CONSTRUCTED AT 3:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENTSLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND ASINDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTEMATERIAL IS HAULED FROM THE PROPERTY THEN THE CONTRACTOR SHALLDISCLOSE THE LOCATION OF ANY ON-SITE AND/OR OFF-SITE BORROW LOCATIONAND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR.BORROW AND WASTE SITES MUST HAVE APPROVE EROSION CONTROL PLAN.13.LIMITS OF CLEARING SHOWN ARE BASED ON CUT AND FILL SLOPES OR OTHERGRADING REQUIREMENTS.14.CONTRACTOR SHALL INSTALL ALL EROSION CONTROL MEASURES AS INDICATEDPRIOR TO GRADING OPERATIONS. NO DEVICE MAY BE REMOVED WITHOUTAPPROVAL OF EROSION CONTROL COORDINATOR.15.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTINGCONTOURS.16.ALL DISTANCES ARE HORIZONTAL GROUND.17.ANCHOR SILT FENCE WITH STONE ON TREE PROTECTION ZONES. DO NOT BURY.18.INLET PROTECTION IS REQUIRED FOR ALL INLETS LOCATED IN THE WORKING AREA19.INLET PROTECTION IS REQUIRED FOR ALL PHASES OF THE PROJECT AND UNTILTHE DISTURBED AREA IS FULLY STABILIZED.20.SEDIMENT TRAP AND BASIN SLOPES SHALL BE STABILIZED AND SEEDEDIMMEDIATELY AFTER CONSTRUCTION.21.CONTRACTOR TO REPLACE ALL STAGING AND STOCKPILE AREAS TO PRECONSTRUCTION CONDITIONS. PROVIDE PHOTO DOCUMENTATION OFPRE-CONSTRUCTION CONDITION AT THESE AREASPROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)PROP. LIMITS OFDISTURBANCE (TYP.)PROP. ROW SILT FENCE(TYP.)EX. SANITARYSEWER (TYP.)EX. STORMWATER(TYP.)PROP. LIMITS OFDISTURBANCE (TYP.)FFE: 666'FFE: 666'FFE: 674' - 3"PROPOSED BUILDING (FORREFERENCE ONLY)ELEVATIONS ARE TO TOP OFFINISHED GRADE. CONTRACTOR TOSUBTRACT PAVEMENT AND/OR SLABSECTION. CUT 1' TO SUB-GRADE.FFE'S PER ARCHITECTURAL GROUNDFLOOR PLAN.PROPERTY LINEPROPERTY LINEPHASE 2ASKIMMER VAULTDRAINAGE AREA : 1.49 ACSURFACE AREA REQUIRED: 3,234 SFSURFACE AREA PROVIDED: 4,000 SFVOLUME PROVIDED: 10,000 CFBOTTOM OF BASIN: 654'SIDE SLOPE: N/APROP. SKIMMER DEWATERINGDEVICESKIMMER SIZE: 3.00"ORIFICE DIAMETER: 2.00"SKIMMER INVERT: 654.00'DE-WATERING TIME: 2.16 DAYSPROP. 12" PVC (TYP.)0.38 AC TO STONE OUTLETROCK CHECK DAMS EVERY50 LF (TYP.)ALL CONSTRUCTION MUST BETHROUGH THE CONSTRUCTIONENTRANCE SHOWN ON THEAPPROVED PLANDITCH 2LIMITS OF DISTURBANCELEGENDLDLDTEMPORARY SILT FENCE (CLDS 30.06A)PROPOSED BAFFLESPROPERTY LINEPROPOSED STABILIZED CONSTRUCTIONENTRANCE (CLDS 30.11A)INLET PROTECTIONTOTAL DENUDED AREA:4.16 ACRESPH 2 AREA:2.59 ACRESPH 2 STABILIZED:1.59 ACRESREMAINING DENUDED:2.57 ACRESCONSTRUCTION SEQUENCE1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE CITY OFCHARLOTTE ENGINEERING DEPARTMENT.2.FLAG THE CONSTRUCTION LIMITS AND MARK ANY TREES, WETLANDS, OR EXISTINGSTRUCTURES NOTED TO REMAIN.3.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH EROSION CONTROLINSPECTOR OF THE CITY ENGINEERING DEPARTMENT TO DISCUSS EROSIONCONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS PRIORTO ANY LAND-DISTURBING ACTIVITY IS A VIOLATION OF THE CITY CODE AND ISSUBJECT TO FINE.4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE.PHASE 15.INSTALL BOX CULVERT BY-PASSPHASE 26.INSTALL ALL TEMPORARY SILT FENCE, TREE PROTECTION, AND ANY OTHERTEMPORARY MEASURES AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.7.INSTALL SKIMMER SEDIMENT BASIN, CHECK DAMS AND DIVERSION DITCHES.8.CALL FOR ON-SITE INSPECTION BY EROSION CONTROL INSPECTOR. WHENAPPROVED, INSPECTOR WILL ISSUE THE GRADING PERMIT AND CLEARING,GRUBBING AND DEMOLITION MAY BEGIN.9.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES ARE INPLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS.10.BEGIN CLEARING, GRUBBING AND DEMOLITION OPERATIONS. CLEARING ANDGRUBBING SHALL BE DONE ONLY IN AREAS WHERE EARTHWORK WILL BEPERFORMED AND ONLY IN AREAS WHERE CONSTRUCTION IS PLANNED TOCOMMENCE WITHIN 14 DAYS AFTER CLEARING AND GRUBBING.11.BEGIN MASS GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURES ASINDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.12.COMPLETE STABILIZATION OF UPPER SITE, 1.60 ACPHASE 2A13.COORDINATE PHASING OUT OF SED BASIN WITH UNDERGROUND VAULTCONSTRUCTION AND SITE INSPECTOR.14.SED BASIN IS REQUIRED TO BE IN PLACE IF GREATER THAN 1.0 AC OF DISTURBEDAREA ARE PRESENTPHASE 315.IN COORDINATION WITH SITE INSPECTOR UNDERGROUND VAULT TO ACT ASSEDIMENT BASIN.16.MAJORITY OF BUILDING FOOTPRINT TO BE STABILIZED IN THIS PHASEPHASE 417.CONTINUE MAINTENANCE OOF EROSION CONTROL MEASURES18.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING ISNECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS ANDESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTIONSEQUENCE.19.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED AND WITH APPROVALFROM EROSION CONTROL INSPECTOR.20.ALL EROSION CONTROL DEVICES SHOULD BE MONITORED ONCE A WEEK AND AFTEREVERY 1" RAIN EVENT OR GREATER BY A CERTIFIED INSPECTOR. IF ANY FAILURESARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE.21.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITHTHE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S.DEPT. OF AGRICULTURE, CITY OF CHARLOTTE, EROSION CONTROL ORDINANCE, ANDTHE CHARLOTTE LAND DEVELOPMENT STANDARDS.22.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENTPROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSIONMUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.23.UPON STABILIZATION OF ALL UPSTREAM AREA, SKIMMER SEDIMENT VAULT TO BEMUCKED OUT AND CONVERTED TO UNDERGROUND DETENTION.PROP. 24" PVC PIPETOP ELEV: 656.00DITCH 4 STSTSTSTGASGASGASGASGASGASGASGASGASGASWWWWWWWWWWWWW WWW W WWWWWWWWWWWWWWWW WWWWWWWWWWWWSS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SS SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASXXSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSTSSSSSSSS663664677665665665670665664665670675675680685690695670675680685690695700675670670670675680690695700705710710705704700695 690 685680675670 665670675665WWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWWW WWWWWWWWWWGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGASGAS GAS GASGASSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSXXXXXXXXXXXXXXXXXXXXXXXXUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPUGPSOUTH CEDAR STREET(ASSUMED 40' PUBLIC R/W PER MB 332-209)STADIUM VIEW DRIVE(35' PUBLIC R/W)R/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WR/WTTTTGGVANLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD LD LD LD LD LD LD LD LD LD LD LD LD LD LD LDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLDLD W STSTSTST ST ST STSTSTSTSTSTSTST W W SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W SSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSS-39AD - 5AD - 4S-35DI - 2AD - 3AD - 1SDMH - 1AD - 2S-486' X 6' RCBS-106' X 6' RCBS-96' X 6' RCBS-1212" RCP 24" RCP 12" RCP 18" RCP18" RCP18" RCP TD->TD->TD->TD->TD->TD->MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EC PH 4N/AC3-056/28/2023 3:37 PM ERIC LEACH P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_PLN_EROS4.DWGKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658LAND DEVELOPMENT1ST SUBMITTAL04.28.20231LAND DEVELOPMENT2nd SUBMITTAL06.28.20232 1" = 20'4020#10EXISTING BUILDINGEXISTING BUILDINGEXISTING BUILDINGPROPOSED PLAZAEROSION CONTROL NOTES:1.CONTRACTOR TO PROVIDE AS MUCH SPACE AS POSSIBLE BETWEEN TOE OF FILLSLOPE AND SILT FENCE.2.PLEASE CONTACT CITY INSPECTOR TO ADVISE ON START DATE AND SCHEDULEPRE-CONSTRUCTION MEETING.3.ON-SITE BURIAL PITS REQUIRE AN ON-SITE DEMOLITION LANDFILL PERMIT FROMTHE ZONING ADMINISTRATOR.4.ANY GRADING BEYOND THE LIMITS OF CONSTRUCTION SHOWN ON THIS PLAN ISSUBJECT TO A FINE.5.GRADING 1 ACRE OR MORE WITHOUT AN APPROVED EROSION CONTROL PLAN IS AVIOLATION AND SUBJECT TO A FINE.6.ALL SLOPES MUST BE SEEDED AND MULCHED WITHIN 7 CALENDAR DAYS.7.ADDITIONAL MEASURES TO CONTROL EROSION AND SEDIMENT MAY BE REQUIREDBY THE EROSION CONTROL COORDINATOR.8.SLOPES SHALL BE GRADED NO STEEPER THAN 3:1. FILL SLOPES GREATER THAN10' REQUIRE ADEQUATE TERRACING. SLOPES GREATER THAN 3:1 SHALL RECEIVEMATTING.9.ALL ELEVATIONS ARE IN REFERENCE TO THE SURVEYORS BENCHMARK WHICHMUST BE VERIFIED BY THE GENERAL CONTRACTOR PRIOR TO GROUND BREAKING.10.ALL CONSTRUCTION TRAFFIC MUST BE THROUGH THE CONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLAN.11.ALL EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH THE N.C.EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL.12.PERMANENT CUT AND FILL SLOPES PLACED ON A SUITABLE FOUNDATION SHOULDBE CONSTRUCTED AT 3:1 (HORIZONTAL TO VERTICAL) OR FLATTER. PERMANENTSLOPES OF 3:1 SHOULD BE CONSTRUCTED WHERE MOWING IS DESIRABLE AND ASINDICATED. IF FILL MATERIAL IS BROUGHT ONTO THE PROPERTY OR IF WASTEMATERIAL IS HAULED FROM THE PROPERTY THEN THE CONTRACTOR SHALLDISCLOSE THE LOCATION OF ANY ON-SITE AND/OR OFF-SITE BORROW LOCATIONAND/OR WASTE BURIAL LOCATION TO THE EROSION CONTROL INSPECTOR.BORROW AND WASTE SITES MUST HAVE APPROVE EROSION CONTROL PLAN.13.LIMITS OF CLEARING SHOWN ARE BASED ON CUT AND FILL SLOPES OR OTHERGRADING REQUIREMENTS.14.CONTRACTOR SHALL INSTALL ALL EROSION CONTROL MEASURES AS INDICATEDPRIOR TO GRADING OPERATIONS. NO DEVICE MAY BE REMOVED WITHOUTAPPROVAL OF EROSION CONTROL COORDINATOR.15.CONTRACTOR SHALL BLEND NEW EARTHWORK SMOOTHLY WITH EXISTINGCONTOURS.16.ALL DISTANCES ARE HORIZONTAL GROUND.17.ANCHOR SILT FENCE WITH STONE ON TREE PROTECTION ZONES. DO NOT BURY.18.INLET PROTECTION IS REQUIRED FOR ALL INLETS LOCATED IN THE WORKING AREA19.INLET PROTECTION IS REQUIRED FOR ALL PHASES OF THE PROJECT AND UNTILTHE DISTURBED AREA IS FULLY STABILIZED.20.SEDIMENT TRAP AND BASIN SLOPES SHALL BE STABILIZED AND SEEDEDIMMEDIATELY AFTER CONSTRUCTION.21.CONTRACTOR TO REPLACE ALL STAGING AND STOCKPILE AREAS TO PRECONSTRUCTION CONDITIONS. PROVIDE PHOTO DOCUMENTATION OFPRE-CONSTRUCTION CONDITION AT THESE AREASLIMITS OF DISTURBANCELEGENDLDLDTEMPORARY SILT FENCE (CLDS 30.06A)PROPOSED BAFFLESPROPERTY LINEPROPOSED STABILIZED CONSTRUCTIONENTRANCE (CLDS 30.11A)INLET PROTECTIONPHASE 2ASKIMMER VAULTDRAINAGE AREA : 1.49 ACSURFACE AREA REQUIRED: 3,234 SFSURFACE AREA PROVIDED: 4,000 SFVOLUME PROVIDED: 10,000 CFBOTTOM OF BASIN: 654'SIDE SLOPE: N/APROP. SKIMMER DEWATERINGDEVICESKIMMER SIZE: 3.00"ORIFICE DIAMETER: 2.00"SKIMMER INVERT: 654.00'DE-WATERING TIME: 2.16 DAYSPROP. 12" PVC TO TIEINTO EX. STORM INLETPROP. 12" PVC (TYP.)EX. SANITARYSEWER (TYP.)EX. STORMWATER (TYP.)DRAINAGE AREADRAINAGE AREAPROPERTY LINEPROPERTY LINETOTAL DENUDED AREA:4.16 ACRESPH 2 AREA:2.59 ACRESPROP. PROJECTLIMITS (TYP.)PROP. SILT FENCE(TYP.)PH 2 STABILIZED:1.59 ACRESREMAINING DENUDED:2.57 ACRESPH 2A DRAINAGE AREATO VAULT.ALL CONSTRUCTION TRAFFIC MUST BETHROUGH THE CONSTRUCTION ENTRANCESHOWN ON THE APPROVED PLANSPROP. CONSTRUCTION ENTRANCEWITH TIRE WASH (TYP.)CONSTRUCTION SEQUENCE1.OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM THE CITY OFCHARLOTTE ENGINEERING DEPARTMENT.2.FLAG THE CONSTRUCTION LIMITS AND MARK ANY TREES, WETLANDS, OR EXISTINGSTRUCTURES NOTED TO REMAIN.3.SET UP AN ON-SITE PRE-CONSTRUCTION CONFERENCE WITH EROSION CONTROLINSPECTOR OF THE CITY ENGINEERING DEPARTMENT TO DISCUSS EROSIONCONTROL MEASURES. FAILURE TO SCHEDULE SUCH CONFERENCE 48 HOURS PRIORTO ANY LAND-DISTURBING ACTIVITY IS A VIOLATION OF THE CITY CODE AND ISSUBJECT TO FINE.4.INSTALL TEMPORARY CONSTRUCTION ENTRANCE.PHASE 15.INSTALL BOX CULVERT BY-PASSPHASE 26.INSTALL ALL TEMPORARY SILT FENCE, TREE PROTECTION, AND ANY OTHERTEMPORARY MEASURES AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.7.INSTALL SKIMMER SEDIMENT BASIN, CHECK DAMS AND DIVERSION DITCHES.8.CALL FOR ON-SITE INSPECTION BY EROSION CONTROL INSPECTOR. WHENAPPROVED, INSPECTOR WILL ISSUE THE GRADING PERMIT AND CLEARING,GRUBBING AND DEMOLITION MAY BEGIN.9.GENERAL CONTRACTOR SHALL ENSURE THAT EROSION CONTROL MEASURES ARE INPLACE AND FUNCTIONING PRIOR TO GRUBBING AND GRADING OPERATIONS.10.BEGIN CLEARING, GRUBBING AND DEMOLITION OPERATIONS. CLEARING ANDGRUBBING SHALL BE DONE ONLY IN AREAS WHERE EARTHWORK WILL BEPERFORMED AND ONLY IN AREAS WHERE CONSTRUCTION IS PLANNED TOCOMMENCE WITHIN 14 DAYS AFTER CLEARING AND GRUBBING.11.BEGIN MASS GRADING, INSTALLING ADDITIONAL EROSION CONTROL MEASURES ASINDICATED, AS REQUIRED, AND AS DEEMED NECESSARY BY THE EROSION CONTROLINSPECTOR.12.COMPLETE STABILIZATION OF UPPER SITE, 1.60 ACPHASE 2A13.COORDINATE PHASING OUT OF SED BASIN WITH UNDERGROUND VAULTCONSTRUCTION AND SITE INSPECTOR.14.SED BASIN IS REQUIRED TO BE IN PLACE IF GREATER THAN 1.0 AC OF DISTURBEDAREA ARE PRESENTPHASE 315.IN COORDINATION WITH SITE INSPECTOR UNDERGROUND VAULT TO ACT ASSEDIMENT BASIN.16.MAJORITY OF BUILDING FOOTPRINT TO BE STABILIZED IN THIS PHASEPHASE 417.CONTINUE MAINTENANCE OOF EROSION CONTROL MEASURES18.STABILIZATION IS THE BEST FORM OF EROSION CONTROL. TEMPORARY SEEDING ISNECESSARY TO ACHIEVE EROSION CONTROL ON LARGE DENUDED AREAS ANDESPECIALLY WHEN SPECIFICALLY REQUIRED AS PART OF THE CONSTRUCTIONSEQUENCE.19.NO DEVICE SHALL BE REMOVED UNTIL SITE IS STABILIZED AND WITH APPROVALFROM EROSION CONTROL INSPECTOR.20.ALL EROSION CONTROL DEVICES SHOULD BE MONITORED ONCE A WEEK AND AFTEREVERY 1" RAIN EVENT OR GREATER BY A CERTIFIED INSPECTOR. IF ANY FAILURESARE FOUND THEY SHOULD BE REPAIRED AS SOON AS POSSIBLE.21.ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITHTHE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, U.S.DEPT. OF AGRICULTURE, CITY OF CHARLOTTE, EROSION CONTROL ORDINANCE, ANDTHE CHARLOTTE LAND DEVELOPMENT STANDARDS.22.APPROVAL OF THIS PLAN IS NOT AN AUTHORIZATION TO GRADE ADJACENTPROPERTIES. WHEN FIELD CONDITIONS WARRANT OFF-SITE GRADING, PERMISSIONMUST BE OBTAINED FROM THE AFFECTED PROPERTY OWNERS.23.UPON STABILIZATION OF ALL UPSTREAM AREA, SKIMMER SEDIMENT VAULT TO BEMUCKED OUT AND CONVERTED TO UNDERGROUND DETENTION.DITCH 4 MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EROSION CONTROL DETAILSN/AC3-066/28/2023 3:37 PM ERIC LEACH P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_DTL_EROS.DWGAS NOTEDKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658LAND DEVELOPMENT1ST SUBMITTAL04.28.20231LAND DEVELOPMENT2nd SUBMITTAL06.28.20232 SSB-1(PH 2)3.682.5724.586,62416,9007,9878,115123101.553.0 in2.5 in1.492.579.954,62610,0003,2344,000123101.553.0 in2.0 inSSB-1(PH 2A)PH 2-DITCH #10.56 AC1.5 ft7.0 ft1.0 ft4.68 ft/sPH 2-DITCH #20.36 AC1.5 ft7.0 ft1.0 ft3.91 ft/sNAG S-150 MATTING OR EQUIVALENTPH 2A-DITCH #10.91 AC1.5 ft7.0 ft1.0 ft6.25 ft/sPH 2A-DITCH #20.21 AC1.5 ft7.0 ft1.0 ft1.90 ft/sNAG S-150 MATTING OR EQUIVALENTNAG S-150 MATTING OR EQUIVALENTPH 2-DITCH #30.22 AC1.5 ft7.0 ft1.0 ft1.78 ft/sPH 2-4-DITCH #40.27 AC1.5 ft7.0 ft1.0 ft2.22 ft/sNAG S-150 MATTING OR EQUIVALENT MODERA AT THEFOUNDRYMILL CREEK RESIDENTIAL TRUSTCHARLOTTENORTH CAROLINA1022147EROSION CONTROL DETAILSN/AC3-076/28/2023 3:38 PM ERIC LEACH P:\CLT\_2022\1022147\CAD\DOCUMENTATION\1022147_DTL_EROS.DWGAS NOTEDKEY MAPSEALSHEET NUMBERSHEET TITLELANDDESIGN PROJ.#SCALEPROJECTNORTHNO.DESCRIPTIONDATEREVISION / ISSUANCEORIGINAL SHEET SIZE: 30" X 42"VERT:HORZ:CHECKED BY:DRAWN BY:DESIGNED BY:223 NORTH GRAHAM STREETCHARLOTTE, NC 28202704.333.0325WWW.LANDDESIGN.COMNC ENG. FIRM LICENSE # C-0658LAND DEVELOPMENT1ST SUBMITTAL04.28.20231LAND DEVELOPMENT2nd SUBMITTAL06.28.20232 DEPARTMENT OF THE ARMY U.S. ARMY CORPS OF ENGINEERS, WILMINGTON DISTRICT CHARLOTTE REGULATORY OFFICE 8430 UNIVERSITY EXECUTIVE PARK DRIVE, SUITE 615 CHARLOTTE NORTH CAROLINA 28262 July 5, 2023 Regulatory Program/Division Mr. Justin Houston Mill Creek Residential Trust 1001 Morehead Square Drive Suite 300 Charlotte, NC 28203 Via Email: jhouston@MCRTrust.com Dear Mr. Houston: This letter is in response to the Pre-Construction Notification (PCN) you submitted to the Wilmington District, Charlotte Regulatory Office on April 20, 2023, for a Department of the Army Nationwide permit (NWP) verification. This project has been assigned the file number SAW-2023-00194 and is known as The Foundry at Cedar Street. This file number should be referenced in all correspondence concerning this project. A review of the information provided indicates that the proposed work would result in permanent impacts of 115 linear feet (0.01 acre) of stream to facilitate construction of a residential development. The project area for this determination includes a 4.78 acre(s) area which is illustrated on the enclosed site plans/maps. The project area is in the eastern quadrant of the intersection of S. Cedar St. and Eldridge St., approximately 0.09 mile northeast of the intersection of S. Cedar St. and W. Morehead St., at Latitude 35.227700 and Longitude -80.854500; in Charlotte, Mecklenburg County, North Carolina. We have determined that the proposed work is authorized by Nationwide Permit 29 (Residential Development). The proposed work must be accomplished in strict accordance with the general permit conditions, any regional conditions, the special conditions listed in this letter, the application materials, and the enclosed plans entitled Foundry at Cedar Street, Impact 1 Storm Plan and Impact 1 Storm Profile, dated 03-01- 2023. If the extent of the project area and/or nature of the authorized impacts to waters are modified, a revised PCN must be submitted to this office for written approval before work is initiated. Any violation of permit conditions or deviation from your submitted plans may subject the permittee to enforcement action. This verification is valid until March 14, 2026, unless prior to this date the subject NWP(s) is suspended, revoked, or is modified such that the activity no longer complies with the terms and conditions of this NWP. If you commence or are under contract to commence this activity before the date that the relevant NWP is modified or revoked, you will have 12 months from the date of the modification or revocation of the NWP to complete the activity under the present terms and conditions of this NWP. Project Specific Special Conditions: 1. Should the Tricolored Bat (Perimyotis subflavus) become listed as threatened or endangered under the Endangered Species Act prior to tree-clearing activities within the Corps action area, the applicant shall commit to a tree clearing moratorium within the Corps action area between April 1 and October 15. Activities subject to Section 404 (as indicated above) may also require an individual Section 401 Water Quality Certification. You should contact the NC Division of Water Resources (telephone 919-807-6300) to determine Section 401 requirements. This NWP verification does not preclude the necessity to obtain any other Federal, State, or local permits, licenses, and/or certifications, which may be required. If you have any questions related to this verification or have issues accessing documents referenced in this letter, please contact Meagan Jolly, Regulatory Specialist of the Charlotte Regulatory Office at 704-578-4506, by mail at the above address, or by email at CharlotteNCREG1@usace.army.mil. Please take a moment to complete our customer satisfaction survey located at https://regulatory.ops.usace.army.mil/ords/f?p=136:4. Sincerely, Meagan Jolly Regulatory Specialist Enclosures Cc (w/enclosures) Christine Geist, NRE Environmental (via cgeist@NREenviro.com) General Conditions (33 CFR PART 320-330): 1. The time limit for completing the work authorized ends on March 14, 2026. 2. You must maintain the activity authorized by this permit in good condition and in conformance with the terms and conditions of this permit. You are not relieved of this requirement if you abandon the permitted activity, although you may make a good faith transfer to a third party in compliance with General Condition 4 below. Should you wish to cease to maintain the authorized activity or should you desire to abandon it without a good faith transfer, you must obtain a modification of this permit from this office, which may require restoration of the area. 3. If you discover any previously unknown historic or archeological remains while accomplishing the activity authorized by this permit, you must immediately notify this office of what you have found. We will initiate the Federal and state coordination required to determine if the remains warrant a recovery effort of if the site is eligible for listing in the National Register of Historic Places. 4. If you sell the property associated with this permit you must obtain the signature of the new owner on the transfer form attached to this letter and forward a copy to this office to validate the transfer of this authorization. 5. If a conditioned water quality certification has been issued for your project, you must comply with the conditions specified in the certification as special conditions to this permit. 6. You must allow a representative from this office to inspect the authorized activity at any time deemed necessary to ensure that it is being or has been accomplished in accordance with the terms and conditions of your permit. Compliance Certification Form Action ID Number: SAW-2023-00194 County: Mecklenburg Permittee: Mill Creek Residential Trust, Mr. Justin Houston Project Name: The Foundry at Cedar Street Date Verification Issued: 7/5/2023 Project Manager: Meagan Jolly Within 30 days of completion of the activity authorized by this permit and any mitigation required by the permit, sign this certification and return it to the following address: US ARMY CORPS OF ENGINEERS Wilmington District Attn: Meagan Jolly Charlotte Regulatory Office U.S Army Corps of Engineers 8430 University Executive Park Drive, Suite 615 Charlotte, North Carolina 28262 or CharlotteNCREG1@usace.army.mil 704-578-4506 Please note that your permitted activity is subject to a compliance inspection by a U. S. Army Corps of Engineers representative. Failure to comply with any terms or conditions of this authorization may result in the Corps suspending, modifying or revoking the authorization and/or issuing a Class I administrative penalty, or initiating other appropriate legal action. I hereby certify that the work authorized by the above referenced permit has been completed in accordance with the terms and condition of the said permit including any general or specific conditions, and the required mitigation was completed in accordance with the permit conditions. __________________________________ ______________________ Signature of Permittee Date TASK ID TASK WORK DAYS Start Finish Total Float COMMENTS MODERA FOUNDRYMODERA FOUNDRY 886 11-Nov-22 A 06-Nov-26 0 MILESTONESMILESTONES 783 03-Oct-23 06-Nov-26 0 1409 TOTAL CONSTRUCTION DURATION 742 04-Dec-23 06-Nov-26 0 **CURRENTLY 35 MOS** PRECONSTRUCTIONPRECONSTRUCTION 41 03-Oct-23 01-Dec-23 0 1185 SUBMIT GMP 0 03-Oct-23 0 1184 GMP APPROVAL 0 17-Oct-23 0 1414 CONTRACT DEVELOPMENT WITH EQUITY PARTNERS / NOTICE TO PROCEED 31 18-Oct-23 01-Dec-23 0 CONSTRUCTIONCONSTRUCTION 385 30-Apr-25 06-Nov-26 0 1163 CONCRETE TOPOUT 0 30-Apr-25 25 4/30/25f per sub+6w 1165 START WOOD FRAMING 0 30-Apr-25 58 1411 PERMANENT POWER 0 08-Sep-25 106 1167 WOOD FRAMING COMPLETE 0 10-Dec-25 0 1153 SUBSTANTIAL COMPLETION - BUILDING A 0 17-Aug-26 58 1149 SUBSTANTIAL COMPLETION - BUILDING B 0 18-Sep-26 35 1151 SUBSTANTIAL COMPLETION - BUILDING C 0 06-Nov-26 0 PRECONSTRUCTIONPRECONSTRUCTION 516 11-Nov-22 A 21-May-25 370 DESIGNDESIGN 42 11-Nov-22 A 05-Sep-23 803 CIVILCIVIL 42 11-Nov-22 A 05-Sep-23 803 1100 ISSUE CIVIL SCHEMATIC DESIGN SET 0 11-Nov-22 A 11/11/22 1102 CIVIL DESIGN DEVELOPMENT SET 10 14-Nov-22 A 18-May-23 A 5/18f 1118 CIVIL GMP DOCUMENT SET 10 19-May-23 A 05-Sep-23 39 9/5f STRUCTURALSTRUCTURAL 42 11-Nov-22 A 05-Sep-23 266 1112 ISSUE STRUCTURAL SCHEMATIC DESIGN SET 0 11-Nov-22 A 1114 STRUCTURAL DESIGN DEVELOPMENT SET 10 14-Nov-22 A 05-Sep-23 266 9/5F 1120 STRUCTURAL GMP DOCUMENT SET 10 19-May-23 A 05-Sep-23 0 9/5F ARCHITECTURALARCHITECTURAL 42 30-Nov-22 A 05-Sep-23 118 1122 ISSUE ARCHITECTURAL SCHEMATIC DESIGN SET 0 30-Nov-22 A 1124 ARCHITECTURAL DESIGN DEVELOPMENT SET 10 01-Dec-22 A 19-May-23 A 1126 ARCHITECTURAL GMP DOCUMENT SET 10 19-May-23 A 05-Sep-23 0 9/5F GMP / PERMITGMP / PERMIT 30 06-Sep-23 17-Oct-23 0 1182 GMP DOCUMENT PRICING 20 06-Sep-23 03-Oct-23 0 4W 1183 GMP REVIEW 10 04-Oct-23 17-Oct-23 0 2W PERMITTINGPERMITTING 122 14-Nov-22 A 30-Oct-23 185 FOUNDATION PERMITFOUNDATION PERMIT 41 14-Nov-22 A 06-Jul-23 266 1116 FOUNDATION PERMIT DOCUMENTS 10 14-Nov-22 A 08-May-23 A 5/8F 1106 SUBMIT FOR FOUNDATION PERMIT 0 08-May-23 A 5/8F 1108 FOUNDATION PERMIT REVIEW 40 09-May-23 A 06-Jul-23 266 5/9S 1110 FOUNDATION PERMIT APPROVAL 0 06-Jul-23 266 BUILDING PERMITBUILDING PERMIT 106 22-May-23 A 30-Oct-23 185 1136 FULL BUILDING PERMIT DOCUMENTS 10 22-May-23 A 01-Sep-23 185 9/1F 1138 SUBMIT FOR FULL BUILDING PERMIT 0 01-Sep-23 185 9/1F 1140 FULL BUILDING PERMIT REVIEW 40 05-Sep-23 30-Oct-23 185 10/30F 1142 FULL BUILDING PERMIT APPROVAL 0 30-Oct-23 185 10/30F PROCUREMENTPROCUREMENT 433 06-Sep-23 21-May-25 217 MOCKUP CONSTRUCTIONMOCKUP CONSTRUCTION 433 06-Sep-23 21-May-25 95 1155 MOCKUP DESIGN & MATERIAL PROCUREMENT 90 06-Sep-23 16-Jan-24 378 1157 MOCKUP CONSTRUCTION 30 27-Feb-25 09-Apr-25 95 AFTER LVL 3 Conc 1159 MOCKUP REVIEW & APPROVAL 30 10-Apr-25 21-May-25 95 **installation only PRECAST BOX CULVERTPRECAST BOX CULVERT 40 06-Sep-23 31-Oct-23 39 1181 EARLY CIVIL PACKAGE AWARD 10 06-Sep-23 19-Sep-23 39 1146 PREPARE SUBMITTALS - CIP BOX CULVERT 20 20-Sep-23 17-Oct-23 39 AFTER CIVIL PCKG AWARD 1148 REVIEW & APPROVAL - CIP BOX CULVERT 10 18-Oct-23 31-Oct-23 39 PRECAST STORMWATER SKIMMER VAULTPRECAST STORMWATER SKIMMER VAULT 30 20-Sep-23 31-Oct-23 208 1143 PREPARE SUBMITTALS - CIP SKIMMER VAULT 20 20-Sep-23 17-Oct-23 208 AFTER CIVIL PCKG AWARD M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D 2023 2024 2025 2026 1409 TOTAL CONSTRUCTION DURATION 1185 SUBMIT GMP 1184 GMP APPROVAL 1414 CONTRACT DEVELOPMENT WITH EQUITY PARTNERS / NOTICE TO PROCEED 1163 CONCRETE TOPOUT 1165 START WOOD FRAMING 1411 PERMANENT POWER 1167 WOOD FRAMING COMPLETE 1153 SUBSTANTIAL COMPLETION - BUILDING A 1149 SUBSTANTIAL COMPLETION - BUILDING B 1151 SUBSTANTIAL COMPLETION - BUILDING C ISSUE CIVIL SCHEMATIC DESIGN SET CIVIL DESIGN DEVELOPMENT SET CIVIL GMP DOCUMENT SET ISSUE STRUCTURAL SCHEMATIC DESIGN SET STRUCTURAL DESIGN DEVELOPMENT SET STRUCTURAL GMP DOCUMENT SET ISSUE ARCHITECTURAL SCHEMATIC DESIGN SET ARCHITECTURAL DESIGN DEVELOPMENT SET ARCHITECTURAL GMP DOCUMENT SET 1182 GMP DOCUMENT PRICING 1183 GMP REVIEW FOUNDATION PERMIT DOCUMENTS SUBMIT FOR FOUNDATION PERMIT FOUNDATION PERMIT REVIEW 1110 FOUNDATION PERMIT APPROVAL FULL BUILDING PERMIT DOCUMENTS 1138 SUBMIT FOR FULL BUILDING PERMIT 1140 FULL BUILDING PERMIT REVIEW 1142 FULL BUILDING PERMIT APPROVAL 1155 MOCKUP DESIGN & MATERIAL PROCUREMENT 1157 MOCKUP CONSTRUCTION 1159 MOCKUP REVIEW & APPROVAL 1181 EARLY CIVIL PACKAGE AWARD 1146 PREPARE SUBMITTALS - CIP BOX CULVERT 1148 REVIEW & APPROVAL - CIP BOX CULVERT 1143 PREPARE SUBMITTALS - CIP SKIMMER VAULT ISSUED 21-Jun-23 DATA DATE 01-Jun-23 MODERA FOUNDRY PRELIMINARY SUMMARIZDE BASELINE SCHEDULE BY AREA - 21-Jun-23 DRAFT PAGE 1 OF 6 FOUND 06-20-23 TASK ID TASK WORK DAYS Start Finish Total Float COMMENTS 1144 REVIEW & APPROVAL - CIP SKIMMER VAULT 10 18-Oct-23 31-Oct-23 208 FOUNDATION REBARFOUNDATION REBAR 85 18-Oct-23 20-Feb-24 109 1186 AWARD CONCRETE PACKAGE 5 18-Oct-23 24-Oct-23 109 AFTER GMP APPRVL 1152 PREPARE SUBMITTALS - FOUNDATION REBAR 30 25-Oct-23 07-Dec-23 109 1154 REVIEW & APPROVAL - FOUNDATION REBAR 20 08-Dec-23 09-Jan-24 109 1156 FABRICATION - FOUNDATION REBAR 30 10-Jan-24 20-Feb-24 109 WOOD TRUSSESWOOD TRUSSES 180 18-Oct-23 03-Jul-24 266 1188 AWARD WOOD FRAMING PACKAGE 20 18-Oct-23 14-Nov-23 266 AFTER GMP APPRVL 1158 PREPARE SUBMITTALS - WOOD TRUSSES 60 15-Nov-23 13-Feb-24 266 1160 REVIEW & APPROVAL - WOOD TRUSSES 20 14-Feb-24 12-Mar-24 266 1162 FABRICATION - WOOD TRUSSES 80 13-Mar-24 03-Jul-24 266 ELECTRICAL SWITCHGEARELECTRICAL SWITCHGEAR 293 18-Oct-23 13-Dec-24 271 1190 AWARD ELECTRICAL PACKAGE 5 18-Oct-23 24-Oct-23 271 AFTER GMP APPRVL 1164 PREPARE SUBMITTALS - SWITCHGEAR 20 25-Oct-23 21-Nov-23 271 1166 REVIEW & APPROVAL - SWITCHGEAR 10 22-Nov-23 07-Dec-23 271 1168 FABRICATION - SWITCHGEAR 258 08-Dec-23 13-Dec-24 271 ORDER BY MILL CREEK WINDOWSWINDOWS 195 18-Oct-23 25-Jul-24 303 1192 AWARD WINDOW PACKAGE 20 18-Oct-23 14-Nov-23 303 AFTER GMP APPRVL 1170 PREPARE SUBMITTALS - WINDOWS 30 15-Nov-23 02-Jan-24 303 1172 REVIEW & APPROVAL - WINDOWS 15 03-Jan-24 23-Jan-24 303 1174 FABRICATION - WINDOWS 130 24-Jan-24 25-Jul-24 303 CABINETSCABINETS 195 18-Oct-23 25-Jul-24 425 1194 AWARD CABINET PACKAGE 20 18-Oct-23 14-Nov-23 425 AFTER GMP APPRVL 1176 PREPARE SUBMITTALS - CABINETS 30 15-Nov-23 02-Jan-24 425 1178 REVIEW & APPROVAL - CABINETS 15 03-Jan-24 23-Jan-24 425 1180 FABRICATION - CABINETS 130 24-Jan-24 25-Jul-24 425 CONSTRUCTIONCONSTRUCTION 742 04-Dec-23 06-Nov-26 0 CIVILCIVIL 168 04-Dec-23 31-Jul-24 574 MOBILIZATION & DEMOMOBILIZATION & DEMO 33 04-Dec-23 22-Jan-24 0 1195 MOBILIZATION 13 04-Dec-23 20-Dec-23 0 12/4S 1196 CONSTRUCTION SITE FENCING & ENTRANCES 5 21-Dec-23 29-Dec-23 0 12/29F 1197 DEMOLITION 15 02-Jan-24 22-Jan-24 0 3W EROSION CONTROL PHASE 1EROSION CONTROL PHASE 1 40 02-Jan-24 26-Feb-24 0 1198 EROSION CONTROL & INSPECTION - CIVIL PHASE 1 20 02-Jan-24 29-Jan-24 0 20D 1199 F/R/P CIP BOX CULVERT - CIVIL PHASE 1 30 02-Jan-24 12-Feb-24 0 W/ EC 6W 1200 TIE INTO EXISTING STORM & BACKFILL - CIVIL PHASE 1 10 13-Feb-24 26-Feb-24 0 2W EROSION CONTROL PHASE 2EROSION CONTROL PHASE 2 90 27-Feb-24 02-Jul-24 0 1207 SEDIMENT BASIN - CIVIL PHASE 2 10 27-Feb-24 11-Mar-24 0 2W 1208 EARTHWORK - CIVIL PHASE 2 80 12-Mar-24 02-Jul-24 0 4M EROSION CONTROL PHASE 3EROSION CONTROL PHASE 3 105 05-Mar-24 31-Jul-24 89 1202 F/R/P CIP SKIMMER VAULT & STORM - CIVIL PHASE 3 30 05-Mar-24 15-Apr-24 124 6W 1204 EARTHWORK - CIVIL PHASE 3 40 05-Jun-24 31-Jul-24 89 2M SANITARY & WATER UTILITIESSANITARY & WATER UTILITIES 20 19-Jun-24 17-Jul-24 584 1209 WATER & FIRE MAINS 20 19-Jun-24 17-Jul-24 584 1206 SANITARY SEWER 20 19-Jun-24 17-Jul-24 584 CONCRETE PODIUMCONCRETE PODIUM 209 03-Jul-24 30-Apr-25 385 LEVEL 1LEVEL 1 173 03-Jul-24 11-Mar-25 421 BUILDING ABUILDING A 113 03-Jul-24 12-Dec-24 481 1101 POUR CRANE PADS & ERECT TOWER CRANES #1 & #2 15 03-Jul-24 24-Jul-24 0 3W 1210 CIP RETAINING WALL FOUNDATIONS - BUILDING A LEVEL 1 15 25-Jul-24 14-Aug-24 0 1211 CIP RETAINING WALL - BUILDING A LEVEL 1 30 06-Aug-24 17-Sep-24 0 1214 FOUNDATIONS - BUILDING A LEVEL 1 20 20-Aug-24 17-Sep-24 0 1415 UNDERSLAB MEP ROUGHIN, VAPOR MITIGATION & INSPECTIONS - BUILDING A 15 04-Sep-24 24-Sep-24 0 3W 1103 PREP & POUR SOG - BUILDING A 10 18-Sep-24 01-Oct-24 0 2W 1234 COLUMNS - BUILDING A LEVEL 1 20 02-Oct-24 29-Oct-24 0 M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D 2023 2024 2025 2026 1144 REVIEW & APPROVAL - CIP SKIMMER VAULT 1186 AWARD CONCRETE PACKAGE 1152 PREPARE SUBMITTALS - FOUNDATION REBAR 1154 REVIEW & APPROVAL - FOUNDATION REBAR 1156 FABRICATION - FOUNDATION REBAR 1188 AWARD WOOD FRAMING PACKAGE 1158 PREPARE SUBMITTALS - WOOD TRUSSES 1160 REVIEW & APPROVAL - WOOD TRUSSES 1162 FABRICATION - WOOD TRUSSES 1190 AWARD ELECTRICAL PACKAGE 1164 PREPARE SUBMITTALS - SWITCHGEAR 1166 REVIEW & APPROVAL - SWITCHGEAR 1168 FABRICATION - SWITCHGEAR 1192 AWARD WINDOW PACKAGE 1170 PREPARE SUBMITTALS - WINDOWS 1172 REVIEW & APPROVAL - WINDOWS 1174 FABRICATION - WINDOWS 1194 AWARD CABINET PACKAGE 1176 PREPARE SUBMITTALS - CABINETS 1178 REVIEW & APPROVAL - CABINETS 1180 FABRICATION - CABINETS 1195 MOBILIZATION 1196 CONSTRUCTION SITE FENCING & ENTRANCES 1197 DEMOLITION 1198 EROSION CONTROL & INSPECTION - CIVIL PHASE 1 1199 F/R/P CIP BOX CULVERT - CIVIL PHASE 1 1200 TIE INTO EXISTING STORM & BACKFILL - CIVIL PHASE 1 1207 SEDIMENT BASIN - CIVIL PHASE 2 1208 EARTHWORK - CIVIL PHASE 2 1202 F/R/P CIP SKIMMER VAULT & STORM - CIVIL PHASE 3 1204 EARTHWORK - CIVIL PHASE 3 1209 WATER & FIRE MAINS 1206 SANITARY SEWER 1101 POUR CRANE PADS & ERECT TOWER CRANES #1 & #2 1210 CIP RETAINING WALL FOUNDATIONS - BUILDING A LEVEL 1 1211 CIP RETAINING WALL - BUILDING A LEVEL 1 1214 FOUNDATIONS - BUILDING A LEVEL 1 1415 UNDERSLAB MEP ROUGHIN, VAPOR MITIGATION & INSPECTIONS - BUILDING A 1103 PREP & POUR SOG - BUILDING A 1234 COLUMNS - BUILDING A LEVEL 1 ISSUED 21-Jun-23 DATA DATE 01-Jun-23 MODERA FOUNDRY PRELIMINARY SUMMARIZDE BASELINE SCHEDULE BY AREA - 21-Jun-23 DRAFT PAGE 2 OF 6 FOUND 06-20-23 TASK ID TASK WORK DAYS Start Finish Total Float COMMENTS 1244 FORM & POUR ELEVATED DECK - BUILDING A LEVEL 1 20 16-Oct-24 12-Nov-24 0 1212 BACKFILL CIP RETAINING WALL - BUILDING A LEVEL 1 20 13-Nov-24 12-Dec-24 481 BUILDING BBUILDING B 113 15-Aug-24 28-Jan-25 451 1216 CIP RETAINING WALL FOUNDATIONS - BUILDING B LEVEL 1 20 15-Aug-24 12-Sep-24 44 1218 CIP RETAINING WALL - BUILDING B LEVEL 1 30 18-Sep-24 29-Oct-24 31 1220 FOUNDATIONS - BUILDING B LEVEL 1 20 02-Oct-24 29-Oct-24 31 1104 UNDERSLAB MEP ROUGHIN, VAPOR MITIGATION & INSPECTIONS - BUILDING B 15 16-Oct-24 05-Nov-24 31 3W 1105 PREP & POUR SOG - BUILDING B 10 30-Oct-24 12-Nov-24 31 2W 1236 COLUMNS - BUILDING B LEVEL 1 20 13-Nov-24 12-Dec-24 31 1242 FORM & POUR ELEVATED DECK - BUILDING B LEVEL 1 20 27-Nov-24 30-Dec-24 31 1222 BACKFILL CIP RETAINING WALL - BUILDING B LEVEL 1 20 31-Dec-24 28-Jan-25 451 BUILDING CBUILDING C 123 13-Sep-24 11-Mar-25 421 1224 CIP RETAINING WALL FOUNDATIONS - BUILDING C LEVEL 1 20 13-Sep-24 10-Oct-24 59 1226 CIP RETAINING WALL - BUILDING C LEVEL 1 30 30-Oct-24 12-Dec-24 36 1228 FOUNDATIONS - BUILDING C LEVEL 1 20 13-Nov-24 12-Dec-24 36 1128 UNDERSLAB MEP ROUGHIN, VAPOR MITIGATION & INSPECTIONS - BUILDING C 15 27-Nov-24 19-Dec-24 36 3W 1130 PREP & POUR SOG - BUILDING C 10 13-Dec-24 30-Dec-24 36 2W 1238 COLUMNS - BUILDING C LEVEL 1 20 31-Dec-24 28-Jan-25 36 1240 FORM & POUR ELEVATED DECK - BUILDING C LEVEL 1 20 15-Jan-25 11-Feb-25 36 1230 BACKFILL CIP RETAINING WALL - BUILDING C LEVEL 1 20 12-Feb-25 11-Mar-25 421 LEVEL 2LEVEL 2 95 07-Nov-24 26-Mar-25 30 1231 CONCRETE STRUCTURE - BUILDING A LEVEL 2 60 07-Nov-24 05-Feb-25 0 1232 CONCRETE STRUCTURE -BUILDING B LEVEL 2 40 16-Dec-24 12-Feb-25 25 1233 CONCRETE STRUCTURE -BUILDING C LEVEL 2 40 30-Jan-25 26-Mar-25 30 LEVEL 3LEVEL 3 100 02-Dec-24 23-Apr-25 30 1246 CONCRETE STRUCTURE -BUILDING A LEVEL 3 60 02-Dec-24 26-Feb-25 0 1248 CONCRETE STRUCTURE -BUILDING B LEVEL 3 55 09-Jan-25 26-Mar-25 25 1250 CONCRETE STRUCTURE -BUILDING C LEVEL 3 40 27-Feb-25 23-Apr-25 30 LEVEL 4LEVEL 4 80 23-Dec-24 16-Apr-25 25 1252 CONCRETE STRUCTURE -BUILDING A LEVEL 4 60 23-Dec-24 19-Mar-25 0 1254 CONCRETE STRUCTURE -BUILDING B LEVEL 4 55 30-Jan-25 16-Apr-25 25 LEVEL 5LEVEL 5 70 23-Jan-25 30-Apr-25 25 1258 CONCRETE STRUCTURE -BUILDING A LEVEL 5 60 23-Jan-25 16-Apr-25 0 1260 CONCRETE STRUCTURE -BUILDING B LEVEL 5 30 20-Mar-25 30-Apr-25 25 GARAGE / RETAIL MEPGARAGE / RETAIL MEP 186 12-Feb-25 03-Nov-25 106 1175 GARAGE MEP INSTALLATION - LEVEL 1 120 12-Feb-25 31-Jul-25 132 1173 GARAGE MEP INSTALLATION - LEVEL 2 120 27-Mar-25 15-Sep-25 111 1169 GARAGE MEP INSTALLATION - LEVEL 4 120 17-Apr-25 06-Oct-25 106 1171 GARAGE MEP INSTALLATION - LEVEL 3 120 01-May-25 20-Oct-25 106 1161 GARAGE MEP INSTALLATION - LEVEL 5 120 15-May-25 03-Nov-25 106 MAIN ELECTRICAL ROOMMAIN ELECTRICAL ROOM 20 11-Aug-25 08-Sep-25 106 1410 WIRE & TERMINATE ELECTRICAL GEAR 20 11-Aug-25 08-Sep-25 106 WOOD FRAMED APARTMENTSWOOD FRAMED APARTMENTS 395 17-Apr-25 06-Nov-26 0 BUILDING A (EAST TO WEST)BUILDING A (EAST TO WEST)337 17-Apr-25 17-Aug-26 58 MASONRY SHAFTSMASONRY SHAFTS 25 17-Apr-25 21-May-25 0 1263 MASONRY SHAFT - STAIR#1 BUILDING A SEQ 1 10 17-Apr-25 30-Apr-25 0 1134 MASONRY SHAFTS - ELEVATOR #1 & 2 BUILDING A SEQ 2 15 01-May-25 21-May-25 0 1221 MASONRY SHAFTS - STAIR#2 BUILDING A SEQ 2 10 08-May-25 21-May-25 0 W/ ELEVATOR SHAFT?? WOOD FRAMINGWOOD FRAMING 97 01-May-25 17-Sep-25 58 LEVEL 6LEVEL 6 25 01-May-25 05-Jun-25 58 1268 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 6 10 01-May-25 14-May-25 58 1132 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 6 10 22-May-25 05-Jun-25 58 LEVEL 7LEVEL 7 30 15-May-25 26-Jun-25 58 1267 TRUSSES & DECK - BUILDING A SEQ 1 LEVEL 7 5 15-May-25 21-May-25 58 1270 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 7 10 22-May-25 05-Jun-25 58 M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D 2023 2024 2025 2026 1244 FORM & POUR ELEVATED DECK - BUILDING A LEVEL 1 1212 BACKFILL CIP RETAINING WALL - BUILDING A LEVEL 1 1216 CIP RETAINING WALL FOUNDATIONS - BUILDING B LEVEL 1 1218 CIP RETAINING WALL - BUILDING B LEVEL 1 1220 FOUNDATIONS - BUILDING B LEVEL 1 1104 UNDERSLAB MEP ROUGHIN, VAPOR MITIGATION & INSPECTIONS - BUILDING B 1105 PREP & POUR SOG - BUILDING B 1236 COLUMNS - BUILDING B LEVEL 1 1242 FORM & POUR ELEVATED DECK - BUILDING B LEVEL 1 1222 BACKFILL CIP RETAINING WALL - BUILDING B LEVEL 1 1224 CIP RETAINING WALL FOUNDATIONS - BUILDING C LEVEL 1 1226 CIP RETAINING WALL - BUILDING C LEVEL 1 1228 FOUNDATIONS - BUILDING C LEVEL 1 1128 UNDERSLAB MEP ROUGHIN, VAPOR MITIGATION & INSPECTIONS - BUILDING C 1130 PREP & POUR SOG - BUILDING C 1238 COLUMNS - BUILDING C LEVEL 1 1240 FORM & POUR ELEVATED DECK - BUILDING C LEVEL 1 1230 BACKFILL CIP RETAINING WALL - BUILDING C LEVEL 1 1231 CONCRETE STRUCTURE - BUILDING A LEVEL 2 1232 CONCRETE STRUCTURE -BUILDING B LEVEL 2 1233 CONCRETE STRUCTURE -BUILDING C LEVEL 2 1246 CONCRETE STRUCTURE -BUILDING A LEVEL 3 1248 CONCRETE STRUCTURE -BUILDING B LEVEL 3 1250 CONCRETE STRUCTURE -BUILDING C LEVEL 3 1252 CONCRETE STRUCTURE -BUILDING A LEVEL 4 1254 CONCRETE STRUCTURE -BUILDING B LEVEL 4 1258 CONCRETE STRUCTURE -BUILDING A LEVEL 5 1260 CONCRETE STRUCTURE -BUILDING B LEVEL 5 1175 GARAGE MEP INSTALLATION - LEVEL 1 1173 GARAGE MEP INSTALLATION - LEVEL 2 1169 GARAGE MEP INSTALLATION - LEVEL 4 1171 GARAGE MEP INSTALLATION - LEVEL 3 1161 GARAGE MEP INSTALLATION - LEVEL 5 1410 WIRE & TERMINATE ELECTRICAL GEAR 1263 MASONRY SHAFT - STAIR#1 BUILDING A SEQ 1 1134 MASONRY SHAFTS - ELEVATOR #1 & 2 BUILDING A SEQ 2 1221 MASONRY SHAFTS - STAIR#2 BUILDING A SEQ 2 1268 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 6 1132 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 6 1267 TRUSSES & DECK - BUILDING A SEQ 1 LEVEL 7 1270 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 7 ISSUED 21-Jun-23 DATA DATE 01-Jun-23 MODERA FOUNDRY PRELIMINARY SUMMARIZDE BASELINE SCHEDULE BY AREA - 21-Jun-23 DRAFT PAGE 3 OF 6 FOUND 06-20-23 TASK ID TASK WORK DAYS Start Finish Total Float COMMENTS 1145 TRUSSES & DECK - BUILDING A SEQ 2 LEVEL 7 5 06-Jun-25 12-Jun-25 58 1150 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 7 10 13-Jun-25 26-Jun-25 58 LEVEL 8LEVEL 8 32 06-Jun-25 22-Jul-25 58 1272 TRUSSES & DECK - BUILDING A SEQ 1 LEVEL 8 7 06-Jun-25 16-Jun-25 58 1274 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 8 10 17-Jun-25 30-Jun-25 58 1201 TRUSSES & DECK - BUILDING A SEQ 2 LEVEL 8 7 27-Jun-25 08-Jul-25 58 1203 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 8 10 09-Jul-25 22-Jul-25 58 LEVEL 9LEVEL 9 30 01-Jul-25 12-Aug-25 58 1276 TRUSSES & DECK - BUILDING A SEQ 1 LEVEL 9 5 01-Jul-25 08-Jul-25 58 1278 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 9 10 09-Jul-25 22-Jul-25 58 1205 TRUSSES & DECK - BUILDING A SEQ 2 LEVEL 9 5 23-Jul-25 29-Jul-25 58 1213 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 9 10 30-Jul-25 12-Aug-25 58 LEVEL 10LEVEL 10 30 23-Jul-25 03-Sep-25 58 1280 TRUSSES & DECK - BUILDING A SEQ 1 LEVEL 10 5 23-Jul-25 29-Jul-25 58 1282 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 10 10 30-Jul-25 12-Aug-25 58 1215 TRUSSES & DECK - BUILDING A SEQ 2 LEVEL 10 5 13-Aug-25 19-Aug-25 58 1217 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 10 10 20-Aug-25 03-Sep-25 58 ROOFROOF 25 13-Aug-25 17-Sep-25 58 1284 ROOF TRUSSES, PARAPETS & DECK - BUILDING A SEQ 1 ROOF 10 13-Aug-25 26-Aug-25 58 1219 ROOF TRUSSES, PARAPETS & DECK - BUILDING A SEQ 2 ROOF 10 04-Sep-25 17-Sep-25 58 ROOFINGROOFING 30 27-Aug-25 08-Oct-25 58 1393 ROOFING - BUILDING A SEQ 1 10 27-Aug-25 10-Sep-25 63 1107 ROOFING - BUILDING A SEQ 2 15 18-Sep-25 08-Oct-25 58 EXTERIOR FINISHESEXTERIOR FINISHES 150 16-Jul-25 19-Feb-26 143 1412 WINDOWS - BUILDING A SEQ 1 30 16-Jul-25 26-Aug-25 58 1177 WINDOWS - BUILDING A SEQ 2 30 27-Aug-25 08-Oct-25 58 1413 MASONRY & SIDING - BUILDING A SEQ 1 90 11-Sep-25 22-Jan-26 163 1179 MASONRY & SIDING - BUILDING A SEQ 2 90 09-Oct-25 19-Feb-26 143 INTERIORSINTERIORS 280 09-Jul-25 17-Aug-26 58 WEATHER RESISTANT ROUGHINWEATHER RESISTANT ROUGHIN 60 09-Jul-25 01-Oct-25 279 PHASE 1PHASE 1 45 09-Jul-25 10-Sep-25 84 1290 PLUMBING ROUGHIN - BUILDING A SEQ 1 ALL LEVELS 35 09-Jul-25*26-Aug-25 94 1294 FIRE PROTECTION - BUILDING A SEQ 1 ALL LEVELS 35 09-Jul-25*26-Aug-25 74 1292 WEATHER RESISTANT MECHANICAL - BUILDING A SEQ 1 ALL LEVELS 30 23-Jul-25*03-Sep-25 74 1308 PREROCK & GYPCRETE AT DEAD SPACES - BUILDING A SEQ 1 ALL LEVELS 20 30-Jul-25 26-Aug-25 84 1296 ELECTRICAL BOXES - BUILDING A SEQ 1 ALL LEVELS 15 13-Aug-25 03-Sep-25 84 1310 SET TUBS - BUILDING A SEQ 1 ALL LEVELS 20 13-Aug-25 10-Sep-25 84 PHASE 2PHASE 2 45 30-Jul-25 01-Oct-25 279 1223 PLUMBING ROUGHIN - BUILDING A SEQ 2 ALL LEVELS 35 30-Jul-25*17-Sep-25 74 1225 FIRE PROTECTION - BUILDING A SEQ 2 ALL LEVELS 35 30-Jul-25*17-Sep-25 284 1227 WEATHER RESISTANT MECHANICAL - BUILDING A SEQ 2 ALL LEVELS 30 13-Aug-25*24-Sep-25 284 1229 PREROCK & GYPCRETE AT DEAD SPACES - BUILDING A SEQ 2 ALL LEVELS 20 20-Aug-25 17-Sep-25 64 1235 ELECTRICAL BOXES - BUILDING A SEQ 2 ALL LEVELS 15 04-Sep-25 24-Sep-25 284 1237 SET TUBS - BUILDING A SEQ 2 ALL LEVELS 20 04-Sep-25 01-Oct-25 64 LEVEL 10LEVEL 10 145 11-Sep-25 09-Apr-26 58 SEQ 1SEQ 1 125 11-Sep-25 11-Mar-26 79 WEATHER SENSITIVE ROUGHINWEATHER SENSITIVE ROUGHIN 14 11-Sep-25 30-Sep-25 79 1298 MECHANICAL ROUGHIN - BUILDING A / SEQ 1 LEVEL 10 5 11-Sep-25 17-Sep-25 69 1306 ELECTRICAL & DATA ROUGHIN - BUILDING A / SEQ 1 LEVEL 10 5 11-Sep-25 17-Sep-25 79 1300 FIRE CAULK - BUILDING A / SEQ 1 LEVEL 10 2 18-Sep-25 19-Sep-25 79 1302 ROUGHIN INSPECTIONS - BUILDING A / SEQ 1 LEVEL 10 5 22-Sep-25 26-Sep-25 79 1304 FIRE MARSHAL INSPECTIONS - BUILDING A / SEQ 1 LEVEL 10 2 29-Sep-25 30-Sep-25 79 INSULATION & INSPECTIONSINSULATION & INSPECTIONS 12 01-Oct-25 16-Oct-25 79 1312 MOISTURE INTRUSION MITIGATION - BUILDING A / SEQ 1 LEVEL 10 3 01-Oct-25 03-Oct-25 79 1322 MOISTURE INTRUSION MITIGATION INSPECTION - BUILDING A / SEQ 1 LEVEL10 1 06-Oct-25 06-Oct-25 79 1320 NETTING & RC CHANNEL - BUILDING A / SEQ 1 LEVEL 10 3 07-Oct-25 09-Oct-25 79 1314 INSPECT NETTING & RC CHANNEL - BUILDING A / SEQ 1 LEVEL 10 1 10-Oct-25 10-Oct-25 79 1316 INSULATE - BUILDING A / SEQ 1 LEVEL 10 3 13-Oct-25 15-Oct-25 79 1318 INSPECT INSULATION - BUILDING A / SEQ 1 LEVEL 10 1 16-Oct-25 16-Oct-25 79 M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D 2023 2024 2025 2026 1145 TRUSSES & DECK - BUILDING A SEQ 2 LEVEL 7 1150 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 7 1272 TRUSSES & DECK - BUILDING A SEQ 1 LEVEL 8 1274 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 8 1201 TRUSSES & DECK - BUILDING A SEQ 2 LEVEL 8 1203 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 8 1276 TRUSSES & DECK - BUILDING A SEQ 1 LEVEL 9 1278 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 9 1205 TRUSSES & DECK - BUILDING A SEQ 2 LEVEL 9 1213 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 9 1280 TRUSSES & DECK - BUILDING A SEQ 1 LEVEL 10 1282 LAYOUT & FRAME WALLS - BUILDING A SEQ 1 LEVEL 10 1215 TRUSSES & DECK - BUILDING A SEQ 2 LEVEL 10 1217 LAYOUT & FRAME WALLS - BUILDING A SEQ 2 LEVEL 10 1284 ROOF TRUSSES, PARAPETS & DECK - BUILDING A SEQ 1 ROOF 1219 ROOF TRUSSES, PARAPETS & DECK - BUILDING A SEQ 2 ROOF 1393 ROOFING - BUILDING A SEQ 1 1107 ROOFING - BUILDING A SEQ 2 1412 WINDOWS - BUILDING A SEQ 1 1177 WINDOWS - BUILDING A SEQ 2 1413 MASONRY & SIDING - BUILDING A SEQ 1 1179 MASONRY & SIDING - BUILDING A SEQ 2 1290 PLUMBING ROUGHIN - BUILDING A SEQ 1 ALL LEVELS 1294 FIRE PROTECTION - BUILDING A SEQ 1 ALL LEVELS 1292 WEATHER RESISTANT MECHANICAL - BUILDING A SEQ 1 ALL LEVELS 1308 PREROCK & GYPCRETE AT DEAD SPACES - BUILDING A SEQ 1 ALL LEVELS 1296 ELECTRICAL BOXES - BUILDING A SEQ 1 ALL LEVELS 1310 SET TUBS - BUILDING A SEQ 1 ALL LEVELS 1223 PLUMBING ROUGHIN - BUILDING A SEQ 2 ALL LEVELS 1225 FIRE PROTECTION - BUILDING A SEQ 2 ALL LEVELS 1227 WEATHER RESISTANT MECHANICAL - BUILDING A SEQ 2 ALL LEVELS 1229 PREROCK & GYPCRETE AT DEAD SPACES - BUILDING A SEQ 2 ALL LEVELS 1235 ELECTRICAL BOXES - BUILDING A SEQ 2 ALL LEVELS 1237 SET TUBS - BUILDING A SEQ 2 ALL LEVELS 1298 MECHANICAL ROUGHIN - BUILDING A / SEQ 1 LEVEL 10 1306 ELECTRICAL & DATA ROUGHIN - BUILDING A / SEQ 1 LEVEL 10 1300 FIRE CAULK - BUILDING A / SEQ 1 LEVEL 10 1302 ROUGHIN INSPECTIONS - BUILDING A / SEQ 1 LEVEL 10 1304 FIRE MARSHAL INSPECTIONS - BUILDING A / SEQ 1 LEVEL 10 1312 MOISTURE INTRUSION MITIGATION - BUILDING A / SEQ 1 LEVEL 10 1322 MOISTURE INTRUSION MITIGATION INSPECTION - BUILDING A / SEQ 1 LEVEL 10 1320 NETTING & RC CHANNEL - BUILDING A / SEQ 1 LEVEL 10 1314 INSPECT NETTING & RC CHANNEL - BUILDING A / SEQ 1 LEVEL 10 1316 INSULATE - BUILDING A / SEQ 1 LEVEL 10 1318 INSPECT INSULATION - BUILDING A / SEQ 1 LEVEL 10 ISSUED 21-Jun-23 DATA DATE 01-Jun-23 MODERA FOUNDRY PRELIMINARY SUMMARIZDE BASELINE SCHEDULE BY AREA - 21-Jun-23 DRAFT PAGE 4 OF 6 FOUND 06-20-23 TASK ID TASK WORK DAYS Start Finish Total Float COMMENTS DRYWALLDRYWALL 18 17-Oct-25 11-Nov-25 79 1324 HANG DRYWALL - BUILDING A / SEQ 1 LEVEL 10 5 17-Oct-25 23-Oct-25 79 1326 TAPE & FINISH DRYWALL - BUILDING A / SEQ 1 LEVEL 10 10 24-Oct-25 06-Nov-25 79 1328 GYPCRETE - BUILDING A / SEQ 1 LEVEL 10 3 07-Nov-25 11-Nov-25 79 FINISHES & FIXTURESFINISHES & FIXTURES 55 12-Nov-25 03-Feb-26 79 1332 INTERIOR DOORS & TRIM - BUILDING A / SEQ 1 LEVEL 10 8 12-Nov-25 21-Nov-25 79 1330 PRIME PAINT - BUILDING A / SEQ 1 LEVEL 10 4 24-Nov-25 01-Dec-25 79 1334 POINT UP & FIRST COAT PAINT - BUILDING A / SEQ 1 LEVEL 10 6 02-Dec-25 09-Dec-25 79 1372 PUTTY & PAINT TRIM - BUILDING A / SEQ 1 LEVEL 10 7 02-Dec-25 10-Dec-25 87 1344 CABINETS - BUILDING A / SEQ 1 LEVEL 10 5 10-Dec-25 16-Dec-25 79 1346 BATHROOM HARD TILE - BUILDING A / SEQ 1 LEVEL 10 5 10-Dec-25 16-Dec-25 87 1370 SET AIR HANDLER - BUILDING A / SEQ 1 LEVEL 10 5 10-Dec-25 16-Dec-25 92 1348 KITCHEN & VANITY TOPS - BUILDING A / SEQ 1 LEVEL 10 3 17-Dec-25 19-Dec-25 79 1338 BACKSPASH - BUILDING A / SEQ 1 LEVEL 10 5 22-Dec-25 30-Dec-25 79 1342 LVT FLOORING - BUILDING A / SEQ 1 LEVEL 10 5 22-Dec-25 30-Dec-25 80 1340 FIXED APPLIANCES (D/W, DISP, MICRO) - BUILDING A / SEQ 1 LEVEL 10 2 31-Dec-25 02-Jan-26 80 1336 PLUMBING FIXTURES & TRIM - BUILDING A / SEQ 1 LEVEL 10 5 31-Dec-25 07-Jan-26 79 1352 HVAC TRIM - BUILDING A / SEQ 1 LEVEL 10 5 31-Dec-25 07-Jan-26 83 1354 LOW VOLTAGE & FIRE ALARM DEVICES - BUILDING A / SEQ 1 LEVEL 10 6 31-Dec-25 08-Jan-26 82 1350 ELECTRICAL DEVICES & TRIM - BUILDING A / SEQ 1 LEVEL 10 6 05-Jan-26 12-Jan-26 80 1356 UNIT ENTRY DOORS & HARDWARE - BUILDING A / SEQ 1 LEVEL 10 4 08-Jan-26 13-Jan-26 79 1360 ROUGH CLEAN - BUILDING A / SEQ 1 LEVEL 10 2 14-Jan-26 15-Jan-26 79 1362 STARTUP AIR HANDLERS - BUILDING A / SEQ 1 LEVEL 10 2 16-Jan-26 19-Jan-26 81 1378 LARGE APPLIANCES (W/D, FRIDGE, RANGE) - BUILDING A / SEQ 1 LEVEL 10 2 16-Jan-26 19-Jan-26 81 1358 SHOWER DOORS - BUILDING A / SEQ 1 LEVEL 10 4 16-Jan-26 21-Jan-26 79 1376 CLOSET & BATH ACCESSORIES - BUILDING A / SEQ 1 LEVEL 10 4 16-Jan-26 21-Jan-26 79 1364 CARPET - BUILDING A / SEQ 1 LEVEL 10 2 22-Jan-26 23-Jan-26 79 1374 PERMANENT UNIT ENTRY HARDWARE - BUILDING A / SEQ 1 LEVEL 10 1 26-Jan-26 26-Jan-26 85 1366 FINAL PAINT - BUILDING A / SEQ 1 LEVEL 10 5 26-Jan-26 30-Jan-26 79 1368 BLINDS - BUILDING A / SEQ 1 LEVEL 10 2 02-Feb-26 03-Feb-26 79 CLEAN & PUNCHCLEAN & PUNCH 26 04-Feb-26 11-Mar-26 79 1380 FINAL CLEAN - BUILDING A / SEQ 1 LEVEL 10 3 04-Feb-26 06-Feb-26 79 1382 GC PUNCH - BUILDING A / SEQ 1 LEVEL 10 10 09-Feb-26 20-Feb-26 79 1392 PUFF CLEAN 1 - BUILDING A / SEQ 1 LEVEL 10 2 23-Feb-26 24-Feb-26 79 1384 OWNER PUNCH INSPECTION - BUILDING A / SEQ 1 LEVEL 10 2 25-Feb-26 26-Feb-26 79 1386 OWNER PUNCH CORRECTIONS - BUILDING A / SEQ 1 LEVEL 10 5 27-Feb-26 05-Mar-26 79 1388 PUFF CLEAN 2 - BUILDING A / SEQ 1 LEVEL 10 2 06-Mar-26 09-Mar-26 79 1390 OWNER ACCEPTANCE INSPECTION & TURNOVER - BUILDING A / SEQ 1 LEVEL 10 2 10-Mar-26 11-Mar-26 79 SEQ 2SEQ 2 125 09-Oct-25 09-Apr-26 58 1400 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 10 125 09-Oct-25 09-Apr-26 58 LEVEL 9LEVEL 9 145 25-Sep-25 23-Apr-26 58 1394 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 9 125 25-Sep-25 26-Mar-26 78 1401 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 9 125 23-Oct-25 23-Apr-26 58 LEVEL 8LEVEL 8 145 09-Oct-25 07-May-26 58 1395 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 8 125 09-Oct-25 09-Apr-26 78 1402 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 8 125 06-Nov-25 07-May-26 58 LEVEL 7LEVEL 7 145 23-Oct-25 21-May-26 58 1396 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 7 125 23-Oct-25 23-Apr-26 78 1403 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 7 125 20-Nov-25 21-May-26 58 LEVEL 6LEVEL 6 145 06-Nov-25 05-Jun-26 58 1397 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 6 125 06-Nov-25 07-May-26 78 1404 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 6 125 08-Dec-25 05-Jun-26 58 LEVEL 5LEVEL 5 145 20-Nov-25 19-Jun-26 58 1398 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 5 125 20-Nov-25 21-May-26 78 1405 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 5 125 22-Dec-25 19-Jun-26 58 INSPECTIONS & TURNOVERINSPECTIONS & TURNOVER 60 22-May-26 17-Aug-26 58 1399 GC QUALITY CONTROL - BUILDING A / SEQ 1 40 22-May-26 20-Jul-26 78 1406 GC QUALITY CONTROL - BUILDING A / SEQ 2 40 22-Jun-26 17-Aug-26 58 BUILDING BBUILDING B 335 22-May-25 18-Sep-26 35 M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D 2023 2024 2025 2026 1324 HANG DRYWALL - BUILDING A / SEQ 1 LEVEL 10 1326 TAPE & FINISH DRYWALL - BUILDING A / SEQ 1 LEVEL 10 1328 GYPCRETE - BUILDING A / SEQ 1 LEVEL 10 1332 INTERIOR DOORS & TRIM - BUILDING A / SEQ 1 LEVEL 10 1330 PRIME PAINT - BUILDING A / SEQ 1 LEVEL 10 1334 POINT UP & FIRST COAT PAINT - BUILDING A / SEQ 1 LEVEL 10 1372 PUTTY & PAINT TRIM - BUILDING A / SEQ 1 LEVEL 10 1344 CABINETS - BUILDING A / SEQ 1 LEVEL 10 1346 BATHROOM HARD TILE - BUILDING A / SEQ 1 LEVEL 10 1370 SET AIR HANDLER - BUILDING A / SEQ 1 LEVEL 10 1348 KITCHEN & VANITY TOPS - BUILDING A / SEQ 1 LEVEL 10 1338 BACKSPASH - BUILDING A / SEQ 1 LEVEL 10 1342 LVT FLOORING - BUILDING A / SEQ 1 LEVEL 10 1340 FIXED APPLIANCES (D/W, DISP, MICRO) - BUILDING A / SEQ 1 LEVEL 10 1336 PLUMBING FIXTURES & TRIM - BUILDING A / SEQ 1 LEVEL 10 1352 HVAC TRIM - BUILDING A / SEQ 1 LEVEL 10 1354 LOW VOLTAGE & FIRE ALARM DEVICES - BUILDING A / SEQ 1 LEVEL 10 1350 ELECTRICAL DEVICES & TRIM - BUILDING A / SEQ 1 LEVEL 10 1356 UNIT ENTRY DOORS & HARDWARE - BUILDING A / SEQ 1 LEVEL 10 1360 ROUGH CLEAN - BUILDING A / SEQ 1 LEVEL 10 1362 STARTUP AIR HANDLERS - BUILDING A / SEQ 1 LEVEL 10 1378 LARGE APPLIANCES (W/D, FRIDGE, RANGE) - BUILDING A / SEQ 1 LEVEL 10 1358 SHOWER DOORS - BUILDING A / SEQ 1 LEVEL 10 1376 CLOSET & BATH ACCESSORIES - BUILDING A / SEQ 1 LEVEL 10 1364 CARPET - BUILDING A / SEQ 1 LEVEL 10 1374 PERMANENT UNIT ENTRY HARDWARE - BUILDING A / SEQ 1 LEVEL 10 1366 FINAL PAINT - BUILDING A / SEQ 1 LEVEL 10 1368 BLINDS - BUILDING A / SEQ 1 LEVEL 10 1380 FINAL CLEAN - BUILDING A / SEQ 1 LEVEL 10 1382 GC PUNCH - BUILDING A / SEQ 1 LEVEL 10 1392 PUFF CLEAN 1 - BUILDING A / SEQ 1 LEVEL 10 1384 OWNER PUNCH INSPECTION - BUILDING A / SEQ 1 LEVEL 10 1386 OWNER PUNCH CORRECTIONS - BUILDING A / SEQ 1 LEVEL 10 1388 PUFF CLEAN 2 - BUILDING A / SEQ 1 LEVEL 10 1390 OWNER ACCEPTANCE INSPECTION & TURNOVER - BUILDING A / SEQ 1 LEVEL 10 1400 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 10 1394 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 9 1401 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 9 1395 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 8 1402 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 8 1396 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 7 1403 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 7 1397 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 6 1404 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 6 1398 ROUGHIN & FINISHES - BUILDING A / SEQ 1 LEVEL 5 1405 ROUGHIN & FINISHES - BUILDING A / SEQ 2 LEVEL 5 1399 GC QUALITY CONTROL - BUILDING A / SEQ 1 1406 GC QUALITY CONTROL - BUILDING A / SEQ 2 ISSUED 21-Jun-23 DATA DATE 01-Jun-23 MODERA FOUNDRY PRELIMINARY SUMMARIZDE BASELINE SCHEDULE BY AREA - 21-Jun-23 DRAFT PAGE 5 OF 6 FOUND 06-20-23 TASK ID TASK WORK DAYS Start Finish Total Float COMMENTS MASONRY SHAFTSMASONRY SHAFTS 30 22-May-25 03-Jul-25 0 1239 MASONRY SHAFTS - STAIR#3 BUILDING B 10 22-May-25 05-Jun-25 0 AFTER A SHAFTS 1264 MASONRY SHAFTS - ELEVATOR #3 & 4 / STAIR#4 BUILDING B 20 06-Jun-25 03-Jul-25 0 AFTER STAIR#3 SHAFT WOOD FRAMINGWOOD FRAMING 75 07-Jul-25 20-Oct-25 0 1286 WOOD FRAMING - BUILDING B 75 07-Jul-25 20-Oct-25 0 ROOFINGROOFING 15 21-Oct-25 10-Nov-25 35 1109 ROOFING - BUILDING B 15 21-Oct-25 10-Nov-25 35 EXTERIOR FINISHESEXTERIOR FINISHES 120 09-Sep-25 03-Mar-26 135 1187 WINDOWS- BUILDING B 30 09-Sep-25 20-Oct-25 50 1189 MASONRY & SIDING- BUILDING B 90 21-Oct-25 03-Mar-26 135 INTERIORSINTERIORS 260 09-Sep-25 18-Sep-26 35 1113 WEATHER RESISTANT ROUGHIN - BUILDING B ALL LEVELS 45 09-Sep-25 10-Nov-25 35 1115 ROUGHIN & FINISHES - BUILDING B LEVEL 10 125 11-Nov-25 12-May-26 35 1117 ROUGHIN & FINISHES - BUILDING B LEVEL 9 125 25-Nov-25 27-May-26 35 1119 ROUGHIN & FINISHES - BUILDING B LEVEL 8 125 11-Dec-25 10-Jun-26 35 1121 ROUGHIN & FINISHES - BUILDING B LEVEL 7 125 30-Dec-25 24-Jun-26 35 1123 ROUGHIN & FINISHES - BUILDING B LEVEL 6 125 14-Jan-26 09-Jul-26 35 1125 ROUGHIN & FINISHES - BUILDING B LEVEL 5 125 28-Jan-26 23-Jul-26 35 1127 GC QUALITY CONTROL - BUILDING B 40 24-Jul-26 18-Sep-26 35 BUILDING CBUILDING C 340 07-Jul-25 06-Nov-26 0 MASONRY SHAFTSMASONRY SHAFTS 20 07-Jul-25 01-Aug-25 15 1266 MASONRY SHAFTS - STAIR #5 BUILDING C 20 07-Jul-25 01-Aug-25 15 AFTER BLDG B SHAFTS WOOD FRAMINGWOOD FRAMING 75 25-Aug-25 10-Dec-25 0 1288 WOOD FRAMING - BUILDING C 75 25-Aug-25 10-Dec-25 0 ROOFINGROOFING 15 11-Dec-25 06-Jan-26 0 1111 ROOFING - BUILDING C 15 11-Dec-25 06-Jan-26 0 EXTERIOR FINISHESEXTERIOR FINISHES 120 28-Oct-25 21-Apr-26 100 1191 WINDOWS - BUILDING C 30 28-Oct-25 10-Dec-25 15 1193 MASONRY & SIDING- BUILDING C 90 11-Dec-25 21-Apr-26 100 INTERIORSINTERIORS 260 28-Oct-25 06-Nov-26 0 1129 WEATHER RESISTANT ROUGHIN - BUILDING C ALL LEVELS 45 28-Oct-25 06-Jan-26 0 1131 ROUGHIN & FINISHES - BUILDING C LEVEL 8 125 07-Jan-26 01-Jul-26 0 1133 ROUGHIN & FINISHES - BUILDING C LEVEL 7 125 21-Jan-26 16-Jul-26 0 1135 ROUGHIN & FINISHES - BUILDING C LEVEL 6 125 04-Feb-26 30-Jul-26 0 1137 ROUGHIN & FINISHES - BUILDING C LEVEL 5 125 18-Feb-26 13-Aug-26 0 1139 ROUGHIN & FINISHES - BUILDING C LEVEL 4 125 04-Mar-26 27-Aug-26 0 1141 ROUGHIN & FINISHES - BUILDING C LEVEL 3 125 18-Mar-26 11-Sep-26 0 1147 GC QUALITY CONTROL - BUILDING C 40 14-Sep-26 06-Nov-26 0 M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D J F M A M J J A S O N D 2023 2024 2025 2026 1239 MASONRY SHAFTS - STAIR#3 BUILDING B 1264 MASONRY SHAFTS - ELEVATOR #3 & 4 / STAIR#4 BUILDING B 1286 WOOD FRAMING - BUILDING B 1109 ROOFING - BUILDING B 1187 WINDOWS- BUILDING B 1189 MASONRY & SIDING- BUILDING B 1113 WEATHER RESISTANT ROUGHIN - BUILDING B ALL LEVELS 1115 ROUGHIN & FINISHES - BUILDING B LEVEL 10 1117 ROUGHIN & FINISHES - BUILDING B LEVEL 9 1119 ROUGHIN & FINISHES - BUILDING B LEVEL 8 1121 ROUGHIN & FINISHES - BUILDING B LEVEL 7 1123 ROUGHIN & FINISHES - BUILDING B LEVEL 6 1125 ROUGHIN & FINISHES - BUILDING B LEVEL 5 1127 GC QUALITY CONTROL - BUILDING B 1266 MASONRY SHAFTS - STAIR #5 BUILDING C 1288 WOOD FRAMING - BUILDING C 1111 ROOFING - BUILDING C 1191 WINDOWS - BUILDING C 1193 MASONRY & SIDING- BUILDING C 1129 WEATHER RESISTANT ROUGHIN - BUILDING C ALL LEVELS 1131 ROUGHIN & FINISHES - BUILDING C LEVEL 8 1133 ROUGHIN & FINISHES - BUILDING C LEVEL 7 1135 ROUGHIN & FINISHES - BUILDING C LEVEL 6 1137 ROUGHIN & FINISHES - BUILDING C LEVEL 5 1139 ROUGHIN & FINISHES - BUILDING C LEVEL 4 1141 ROUGHIN & FINISHES - BUILDING C LEVEL 3 1147 GC QUALITY CONTROL - BUILDING C ISSUED 21-Jun-23 DATA DATE 01-Jun-23 MODERA FOUNDRY PRELIMINARY SUMMARIZDE BASELINE SCHEDULE BY AREA - 21-Jun-23 DRAFT PAGE 6 OF 6 FOUND 06-20-23 EMP Attachment 6.0Summary of Soil Analytical DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina Method Analyte Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result QAcetone0.038 0.036 0.032 0.016 J 0.074 0.009 J 0.031 J 0.012 J 0.014 J 0.004 J 0.041 0.006 J 25 14,000 210,000Benzene<0.0007 <0.0007 <0.0007 <0.0007 <0.0007 <0.0008 <0.0009 <0.0008 <0.0007 <0.0007 <0.0007 <0.0008 0.01 1.2 5.4Carbon Disulfide <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.001 <0.0009 <0.0008 <0.0008 <0.0008 <0.0009 4.1 160 740n-Hexane <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0009 <0.001 <0.0009 <0.0008 <0.0008 <0.0008 <0.0009 55 130 540Methyl Ethyl Ketone <0.0008 <0.0008 <0.0008 <0.0008 0.003 J <0.0009 <0.001 <0.0009 <0.0008 <0.0008 <0.0008 <0.0009 17 5,500 40,000Methylene Chloride 0.002 B J 0.001 B J 0.002 B J 0.001 B J <0.001 0.002 B J 0.004 B J 0.003 B J 0.002 B J <0.001 <0.001 <0.002 0.025 58 650Toluene<0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0009 <0.001 <0.0009 <0.0008 <0.0008 <0.0008 <0.0009 8.3 990 9,700Anthracene<0.171 <0.173 <0.180 <0.178 <0.182 <0.189 <0.231 <0.195 <0.175 <0.175 <0.182 <0.200 1300 3,600 45,000Benzo(a)anthracene <0.166 <0.168 <0.175 <0.173 <0.177 <0.184 <0.224 <0.190 <0.170 <0.170 <0.177 <0.194 0.35 1.1 21Benzo(a)pyrene <0.176 <0.178 <0.185 <0.183 <0.187 <0.194 <0.237 <0.201 <0.179 <0.179 <0.187 <0.205 0.12 0.11 2.1Benzo(b)fluoranthene 0.279 J <0.176 <0.184 <0.181 0.192 J <0.193 <0.235 <0.199 <0.178 <0.178 <0.186 <0.204 1.2 1.1 21Benzo(ghi)perylene <0.163 <0.164 <0.171 <0.169 <0.173 <0.180 <0.219 <0.186 <0.166 <0.166 <0.173 <0.190 NS NS NSBenzo(k)fluoranthene <0.164 <0.166 <0.172 <0.170 <0.174 <0.181 <0.221 <0.187 <0.167 <0.167 <0.174 <0.191 12 11 210Chrysene<0.170 <0.172 <0.179 <0.176 <0.180 <0.188 <0.229 <0.194 <0.173 <0.173 <0.181 <0.198 36 110 2,100Fluoranthene0.219 J <0.149 <0.155 <0.153 <0.156 <0.163 <0.198 <0.168 <0.150 <0.150 <0.156 <0.172 670 480 6,000Indeno(123-cd)pyrene <0.214 <0.216 <0.226 <0.222 <0.228 <0.237 <0.289 <0.244 <0.219 <0.219 <0.228 <0.250 3.9 1.1 211-Methylnaphthalene <0.127 <0.128 <0.133 <0.132 <0.135 <0.140 <0.171 <0.145 <0.129 <0.129 <0.135 <0.148 0.11 18 732-Methylnaphthalene <0.120 <0.121 <0.126 <0.124 <0.127 <0.132 <0.161 <0.136 <0.122 <0.122 <0.127 <0.140 3.1 48 600Naphthalene<0.001 <0.174 <0.181 <0.179 <0.183 <0.190 <0.232 <0.196 <0.176 <0.176 <0.183 <0.201 0.39 2.1 8.8Phenanthrene<0.249 <0.252 <0.262 <0.259 <0.264 <0.275 <0.336 <0.284 <0.254 <0.254 <0.265 <0.291 NS NS NSPyrene0.19 J <0.162 <0.169 <0.166 <0.170 <0.177 <0.216 <0.183 <0.164 <0.164 <0.170 <0.187 440 360 4,500Arsenic1.52 1.87 1.04 0.725 3.41 0.934 1.27 1.76 3.01 2.04 1.05 0.758 5.8 0.68 3.0 100 1.2-2.7 4.1-12.4 0.467-7.5Barium45.3 55.9 230 63.9 90.7 64.1 93.9 64.3 75 31.1 39.4 37.3 580 3,100 47,000 2,000 64-220 37.9-66.3 8.21-192Cadmium<0.0310 0.089 J <0.0327 <0.0322 0.247 J 0.0432 J <0.0418 0.0823 J 0.0652 J <0.0317 <0.0330 0.0455 J 3 1.4 20 20 <0.05 0.087-0.24 0.036-0.97Lead12.4 38.1 8.02 12.1 87.8 4.55 3.91 2.85 24.4 5.56 4.39 3.39 270 400 800 100 6.6-18 12.1-24.9 3.1-107Selenium0.653 0.627 1.49 0.702 1.16 0.834 1.76 5.4 1.18 0.728 0.359 0.753 2.1 78 1,200 20 1.2J-4.1 1.1-3.5 <0.097-0.85Silver0.0165 J 0.0393 J 0.0135 J <0.0083 0.134 J 0.0221 J 0.0554 J 0.0224 J 0.0766 J 0.0143 J 0.0423 J 0.0348 J 3.4 78 1,200 100 <0.07 <0.2-0.3 <0.04-0.358Chromium (Total)40.5 36.2 26.4 9.38 63.3 78.6 43.5 63.2 39.2 23.9 10.7 33.1 NS NS NS -37-90 21.1-32.8 1.8-103Chromium (Trivalent)40.5 36.2 26.4 9.38 63.3 77.5 41.8 59.3 38.4 23.9 10.7 31.5 360000 23000 350000 -35-90 21.1-32.8 1.8-103SW7199Chromium Hexavalent <0.169 <0.173 <0.178 <0.178 <0.179 1.07 1.73 3.95 0.811 <0.173 <0.179 1.57 3.8 0.31 6.5 100 0.27-2 <0.319 <2.7-<46.6Chromium TCLP ---------------5.0 ---Lead TCLP ---------------5.0 ---7471A Mercury (Total)<0.0267 0.0948 J 0.0574 J <0.0279 0.194 J 0.0347 J <0.0318 <0.0294 0.127 J 0.0404 J <0.0251 <0.0304 1 2.3 9.7 4 0.032J-0.074 0.028-0.053 <0.01-0.35Notes:All concentrations are reported in mg/kg (milligrams per kilogram). Chromium (Trivalent) calculated by subtracting Chromium Hexavalent from Chromium (Total). The Rule of 20 Values are derived from a 1:20 factor of the United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), November 2004, Maximum Concentration of Contaminants for Toxicity Characteristic.NS = No screening level established; - = Not applicableQ = Qualifier; J = Laboratory estimated value below the lowest calibration point/reporting limit; B = Analyte also detected in associated method blankBold = Detection; Bold/Highlight = Exceedance of the PSRG or Rule of 20 Value; Underlined = Exceedance of Protection of Groundwater PSRGItalicized = Exceedance of Old 27 Landfill Background Metal Concentration; Blue = Exceedance of Griffin Farms Landfill Background Metal ConcentrationDUP-1 sampled at EX-8 (2-5'); DUP-2 sampled at EX-1 (0-2') Protection of Groundwater PSRG Residential PSRG10-20'0-2'2-5'5-10'0-2'DUP-2 2-5'5-10'0-2'2-5'5-10'Griffin Farms Landfill BackgroundSample ID EX-1 EX-2 EX-3 10-20'Industrial/ Commercial PSRG Rule of 20/ TCLP Value Old 27 Landfill Background Tarmac Virginia - 8260D -- Date Collected 04/19/23 04/20/23 04/18/23 8070E Laboratory analytical results were screened against the North Carolina Department of Environmental Quality (NCDEQ) Health-Based Preliminary Soil Remediation Goals (PSRG), January 2023, Rule of 20 Values, United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), May 2021, and background metals concentrations of Old 27 LCID Landfill (BF No. 20050-16-060), May 2021, Griffin Farms LCID, March 2021, and Tarmac Virginia Brownfields Property (BF No. 26067-22-060), June 2022. - 6020B SW6010D ONE Page 1 of 5 AP Foundry, LP EMP Attachment 6.0Summary of Soil Analytical DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina Method Analyte Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result QAcetone0.012 J 0.035 0.018 J 0.005 J 0.017 J 0.075 0.019 J 0.008 J 0.061 0.026 0.021 J 0.014 J 25 14,000 210,000Benzene<0.0007 <0.0007 <0.0008 <0.0008 <0.0008 <0.0007 <0.0007 <0.0007 <0.0007 <0.0007 <0.0007 <0.0007 0.01 1.2 5.4Carbon Disulfide <0.0008 <0.0008 <0.0009 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 4.1 160 740n-Hexane <0.0008 <0.0008 <0.0009 <0.0009 <0.0009 <0.0008 <0.0008 <0.0008 <0.0008 <0.0009 <0.0008 <0.0008 55 130 540Methyl Ethyl Ketone (MEK)<0.0008 <0.0008 <0.0009 <0.0008 <0.0009 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 17 5,500 40,000Methylene Chloride 0.003 B J 0.003 B J 0.002 B J <0.001 <0.001 <0.001 0.002 B J <0.001 0.002 B J 0.002 B J 0.002 B J 0.002 B J 0.025 58 650Toluene<0.0008 <0.0008 <0.0009 <0.0009 <0.0009 <0.0008 <0.0008 <0.0008 <0.0008 <0.0009 <0.0008 <0.0008 8.3 990 9,700Anthracene<0.178 <0.176 <0.191 <0.185 <0.187 <0.173 <0.169 <0.172 <0.182 <0.184 <0.171 <0.183 1300 3,600 45,000Benzo(a)anthracene <0.173 <0.171 <0.186 <0.180 <0.182 <0.168 <0.164 <0.167 <0.177 <0.179 <0.166 <0.178 0.35 1.1 21Benzo(a)pyrene <0.183 <0.181 <0.196 <0.191 <0.192 <0.178 <0.173 <0.177 <0.187 <0.189 <0.176 <0.188 0.12 0.11 2.1Benzo(b)fluoranthene <0.181 <0.180 <0.195 <0.189 <0.191 0.201 J <0.172 <0.176 <0.186 <0.188 <0.174 <0.187 1.2 1.1 21Benzo(ghi)perylene <0.169 <0.167 <0.182 <0.176 <0.178 <0.164 <0.160 <0.164 <0.173 <0.175 <0.162 <0.174 NS NS NSBenzo(k)fluoranthene <0.170 <0.169 <0.183 <0.178 <0.179 <0.166 <0.161 <0.165 <0.174 <0.176 <0.164 <0.175 12 11 210Chrysene<0.176 <0.175 <0.190 <0.184 <0.186 <0.172 <0.167 <0.171 <0.181 <0.183 <0.170 <0.182 36 110 2,100Fluoranthene<0.153 <0.151 <0.164 <0.159 <0.161 0.22 J <0.145 <0.148 <0.157 <0.158 <0.147 <0.157 670 480 6,000Indeno(123-cd)pyrene <0.222 <0.220 <0.239 <0.232 <0.234 <0.216 <0.211 <0.216 <0.228 <0.230 <0.214 <0.229 3.9 1.1 211-Methylnaphthalene <0.132 <0.130 <0.141 <0.137 <0.139 <0.128 <0.125 <0.128 <0.135 <0.136 <0.126 <0.135 0.11 18 732-Methylnaphthalene <0.124 <0.123 <0.133 <0.130 <0.131 <0.121 <0.118 <0.120 <0.127 <0.129 <0.119 <0.128 3.1 48 600Naphthalene<0.179 <0.177 <0.192 <0.187 <0.188 <0.174 <0.170 <0.173 <0.183 <0.185 <0.172 <0.184 0.39 2.1 8.8Phenanthrene<0.259 <0.256 <0.278 <0.270 <0.272 <0.252 <0.245 <0.251 <0.265 <0.268 <0.249 <0.266 NS NS NSPyrene<0.166 <0.165 <0.179 <0.174 <0.175 <0.162 <0.158 <0.161 <0.171 <0.172 <0.160 <0.171 440 360 4,500Arsenic2.13 1.03 0.465 0.906 0.839 3.49 0.957 0.54 1.18 0.872 0.326 0.576 5.8 0.68 3.0 100 1.2-2.7 4.1-12.4 0.467-7.5Barium21.8 16 30.1 41.4 24.1 158 28.3 36.1 41.5 47.5 24.2 84.2 580 3,100 47,000 2,000 64-220 37.9-66.3 8.21-192Cadmium<0.0322 <0.0319 <0.0346 0.0387 J <0.0339 0.966 <0.0306 <0.0312 0.0333 J <0.0334 <0.0310 0.0633 J 3 1.4 20 20 <0.05 0.087-0.24 0.036-0.97Lead5.14 5.89 4.2 4.53 6.5 104 6.87 5.79 11.8 12.4 5.11 11.7 270 400 800 100 6.6-18 12.1-24.9 3.1-107Selenium0.495 0.696 0.618 2.39 0.467 1.61 0.379 0.956 0.615 0.494 0.39 0.542 2.1 78 1,200 20 1.2-4.1 1.1-3.5 <0.097-0.85Silver<0.0083 0.0087 J <0.0090 0.017 J <0.0088 0.404 0.0094 J <0.0081 0.0178 J 0.0277 J <0.0080 0.0774 J 3.4 78 1,200 100 <0.07 <0.2-0.3 <0.04-0.358Chromium (Total)22.4 20.1 5.26 28.5 34.5 26.3 8.44 5.70 23.5 123 7.88 265 NS NS NS -37-90 21.1-32.8 1.8-103Chromium (Trivalent)22.4 20.1 5.26 28.5 34.2 25.4 8.44 5.70 23.5 122 7.88 262 360000 23000 350000 -35-90 21.1-32.8 1.8-103SW7199Chromium Hexavalent <0.175 <0.174 <0.188 <0.183 0.314 0.864 <0.166 <0.170 <0.181 1.33 <0.170 2.72 3.8 0.31 6.5 100 0.27-2 <0.319 <2.7-<46.6Chromium TCLP ---------<0.012 -0.295 ---5.0 ---Lead TCLP -----0.041 ---------5.0 ---7471A Mercury (Total)0.0334 J <0.0269 <0.0282 <0.0294 <0.0293 2.79 0.136 J <0.0252 0.0639 J 0.0759 J <0.0267 <0.0260 1 2.3 9.7 4 0.037-0.074 0.028-0.053 <0.01-0.35Notes:All concentrations are reported in mg/kg (milligrams per kilogram). Chromium (Trivalent) calculated by subtracting Chromium Hexavalent from Chromium (Total). The Rule of 20 Values are derived from a 1:20 factor of the United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), November 2004, Maximum Concentration of Contaminants for Toxicity Characteristic.NS = No screening level established; - = Not applicableQ = Qualifier; J = Laboratory estimated value below the lowest calibration point/reporting limit; B = Analyte also detected in associated method blankBold = Detection; Bold/Highlight = Exceedance of the PSRG or Rule of 20 Value; Underlined = Exceedance of Protection of Groundwater PSRGItalicized = Exceedance of Old 27 Landfill Background Metal Concentration; Blue = Exceedance of Griffin Farms Landfill Background Metal ConcentrationDUP-1 sampled at EX-8 (2-5'); DUP-2 sampled at EX-1 (0-2') 0-2'2-5'5-10'10-20'0-2'Industrial/ Commercial PSRG Rule of 20/ TCLP ValueEX-6 Protection of Groundwater PSRG Residential PSRG10-20'Sample ID EX-4 EX-52-5'5-10'10-20'Old 27 Landfill Background0-2'2-5'5-10' 8260D -- 04/17/23 Griffin Farms Landfill BackgroundDate Collected 04/19/23 8070E SW6010D Laboratory analytical results were screened against the North Carolina Department of Environmental Quality (NCDEQ) Health-Based Preliminary Soil Remediation Goals (PSRG), January 2023, Rule of 20 Values, United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), May 2021, and background metals concentrations of Old 27 LCID Landfill (BF No. 20050-16-060), May 2021, Griffin Farms LCID, March 2021, and Tarmac Virginia Brownfields Property (BF No. 26067-22-060), June 2022. Tarmac Virginia -- 6020B ONE Page 2 of 5 AP Foundry, LP EMP Attachment 6.0Summary of Soil Analytical DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina Method Analyte Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result QAcetone0.023 0.02 J 0.071 0.008 J 0.062 0.071 0.09 0.027 0.012 J 0.048 0.031 0.013 J 25 14,000 210,000Benzene<0.0007 <0.0007 <0.0006 <0.0007 <0.0007 <0.0007 <0.0007 0.002 J <0.0007 <0.0007 <0.0007 <0.0007 0.01 1.2 5.4Carbon Disulfide <0.0008 <0.0008 <0.0007 <0.0007 <0.0008 <0.0007 <0.0007 <0.0007 <0.0008 <0.0007 <0.0008 <0.0008 4.1 160 740n-Hexane <0.0008 <0.0008 <0.0007 <0.0008 <0.0008 <0.0008 <0.0008 0.008 J <0.0008 <0.0008 <0.0008 <0.0008 55 130 540Methyl Ethyl Ketone (MEK)<0.0008 <0.0008 <0.0007 <0.0007 <0.0008 <0.0007 <0.0008 <0.0008 <0.0008 <0.0007 <0.0008 <0.0008 17 5,500 40,000Methylene Chloride <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 <0.001 0.001 B J 0.001 B J 0.025 58 650Toluene<0.0008 <0.0008 <0.0007 <0.0008 <0.0008 <0.0008 <0.0008 0.001 J <0.0008 <0.0008 <0.0008 <0.0008 8.3 990 9,700Anthracene<0.169 <0.183 <0.158 <0.162 <0.170 <0.163 <0.166 <0.165 <0.175 <0.163 <0.177 <0.177 1300 3,600 45,000Benzo(a)anthracene <0.164 <0.178 <0.153 <0.158 <0.166 <0.159 <0.162 <0.161 <0.170 0.216 J <0.172 <0.172 0.35 1.1 21Benzo(a)pyrene <0.174 <0.188 <0.162 <0.167 0.217 J <0.168 <0.171 <0.170 <0.180 0.231 J <0.182 <0.182 0.12 0.11 2.1Benzo(b)fluoranthene <0.173 <0.187 <0.161 <0.166 0.329 J <0.167 <0.170 <0.169 <0.179 0.412 J <0.181 <0.181 1.2 1.1 21Benzo(ghi)perylene <0.161 <0.174 <0.150 <0.154 0.166 J <0.155 <0.158 <0.157 <0.167 0.216 J <0.169 <0.169 NS NS NSBenzo(k)fluoranthene <0.162 <0.175 <0.151 <0.156 <0.163 <0.157 <0.159 <0.158 <0.168 <0.156 <0.170 <0.170 12 11 210Chrysene<0.168 <0.182 <0.156 <0.161 0.201 J <0.162 <0.165 <0.164 <0.174 0.195 J <0.176 <0.176 36 110 2,100Fluoranthene<0.145 <0.157 <0.135 <0.140 0.228 J <0.141 <0.143 <0.142 <0.151 0.324 J <0.152 <0.152 670 480 6,000Indeno(123-cd)pyrene <0.212 <0.229 <0.197 <0.203 <0.213 <0.205 <0.208 <0.207 <0.219 0.242 J <0.222 <0.222 3.9 1.1 211-Methylnaphthalene <0.125 <0.135 <0.117 <0.120 0.419 J <0.121 <0.123 <0.122 <0.130 <0.121 <0.131 <0.131 0.11 18 732-Methylnaphthalene <0.118 <0.128 <0.110 <0.113 0.522 J <0.114 <0.116 <0.116 <0.122 <0.114 <0.124 <0.124 3.1 48 600Naphthalene<0.170 <0.184 <0.159 <0.164 0.489 J <0.165 <0.168 <0.167 <0.176 <0.164 <0.179 <0.179 0.39 2.1 8.8Phenanthrene<0.246 <0.266 <0.229 <0.236 0.313 J <0.238 <0.242 <0.241 <0.255 0.239 J <0.258 <0.258 NS NS NSPyrene<0.158 <0.171 <0.148 <0.152 0.234 J <0.153 <0.156 <0.155 <0.164 0.21 J <0.166 <0.166 440 360 4,500Arsenic1.89 0.821 0.486 0.386 3.48 1.36 1.47 0.458 0.585 2.71 0.932 0.6 5.8 0.68 3 100 1.2-2.7 4.1-12.4 0.467-7.5Barium74.9 48.8 57.2 53.1 183 122 125 27.5 76.7 97.4 63.3 103 580 3,100 47,000 2,000 64-220 37.9-66.3 8.21-192Cadmium<0.0307 <0.0332 <0.0286 0.0333 J 0.489 0.153 J 0.225 J <0.0300 0.0675 J 0.476 0.0592 J 0.0924 J 3 1.4 20 20 <0.05 0.087-0.24 0.036-0.97Lead21.5 7.99 7.07 5.13 165 65.5 112 4.03 5.29 106 9.73 5.16 270 400 800 100 6.6-18 12.1-24.9 3.1-107Selenium0.76 0.355 0.781 0.351 0.967 0.707 0.592 0.259 J 1.34 1.04 1.03 1.32 2.1 78 1,200 20 1.2-4.1 1.1-3.5 <0.097-0.85Silver0.0339 J 0.0097 J 0.0077 J 0.0086 J 0.271 J 0.108 J 0.127 J 0.0078 J 0.0151 J 0.131 J 0.0117 J 0.0103 J 3.4 78 1,200 100 <0.07 <0.2-0.3 <0.04-0.358Chromium (Total)47.2 14.0 4.54 5.07 32.1 16.9 13.5 6.45 47.3 31.6 68.9 48.3 NS NS NS -37-90 21.1-32.8 1.8-103Chromium (Trivalent)47.2 14.0 4.54 5.07 31.7 16.4 12.8 6.45 47.1 31.6 68.9 48.3 360000 23000 350000 -35-90 21.1-32.8 1.8-103SW7199Chromium Hexavalent <0.172 <0.183 <0.160 <0.160 0.375 0.54 0.74 <0.169 0.211 J <0.160 <0.175 <0.175 3.8 0.31 6.5 100 0.27-2 <0.319 <2.7-<46.6Chromium TCLP ---------------5.0 ---Lead TCLP ----1.14 ----------5.0 ---7471A Mercury (Total)0.136 J <0.0278 0.0286 J <0.0235 0.578 <0.0253 0.11 J 0.0305 J <0.0249 0.207 J 0.0525 J <0.0254 1 2.3 9.7 4 0.037-0.074 0.028-0.053 <0.01-0.35Notes:All concentrations are reported in mg/kg (milligrams per kilogram). Chromium (Trivalent) calculated by subtracting Chromium Hexavalent from Chromium (Total). The Rule of 20 Values are derived from a 1:20 factor of the United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), November 2004, Maximum Concentration of Contaminants for Toxicity Characteristic.NS = No screening level established; - = Not applicableQ = Qualifier; J = Laboratory estimated value below the lowest calibration point/reporting limit; B = Analyte also detected in associated method blankBold = Detection; Bold/Highlight = Exceedance of the PSRG or Rule of 20 Value; Underlined = Exceedance of Protection of Groundwater PSRGItalicized = Exceedance of Old 27 Landfill Background Metal Concentration; Blue = Exceedance of Griffin Farms Landfill Background Metal ConcentrationDUP-1 sampled at EX-8 (2-5'); DUP-2 sampled at EX-1 (0-2') Sample ID EX-7 2-5'5-10'0-2'2-5'DUP-1 5-10'10-18.5'0-2'EX-8 EX-9 Protection of Groundwater PSRG Residential PSRG Rule of 20/ TCLP Value Old 27 Landfill Background04/17/23 04/19/23 Griffin Farms Landfill BackgroundIndustrial/ Commercial PSRG5-10'10-20' 8260D Date Collected 8070E 0-2'2-5' SW6010D -- Laboratory analytical results were screened against the North Carolina Department of Environmental Quality (NCDEQ) Health-Based Preliminary Soil Remediation Goals (PSRG), January 2023, Rule of 20 Values, United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), May 2021, and background metals concentrations of Old 27 LCID Landfill (BF No. 20050-16-060), May 2021, Griffin Farms LCID, March 2021, and Tarmac Virginia Brownfields Property (BF No. 26067-22-060), June 2022. Tarmac Virginia -- 6020B ONE Page 3 of 5 AP Foundry, LP EMP Attachment 6.0Summary of Soil Analytical DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina Method Analyte Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result QAcetone0.03 0.015 J 0.016 J 0.094 0.067 0.019 J 0.018 J 0.068 0.052 0.018 J 0.013 J 25 14,000 210,000Benzene<0.0007 <0.0007 <0.0007 <0.0007 <0.0007 <0.0007 <0.0007 <0.0007 <0.0007 <0.0008 <0.0008 0.01 1.2 5.4Carbon Disulfide <0.0008 <0.0008 0.001 J <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 4.1 160 740n-Hexane <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0009 <0.0009 <0.0009 55 130 540Methyl Ethyl Ketone (MEK)<0.0008 <0.0008 <0.0008 0.004 J <0.0008 <0.0008 <0.0008 0.002 J <0.0008 <0.0009 <0.0009 17 5,500 40,000Methylene Chloride 0.002 B J <0.001 0.002 B J <0.001 <0.001 0.002 B J 0.002 B J 0.002 B J 0.002 B J 0.002 B J 0.002 B J 0.025 58 650Toluene<0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0008 <0.0009 <0.0009 <0.0009 8.3 990 9,700Anthracene<0.176 0.183 J <0.181 <0.175 <0.178 <0.171 <0.180 <0.179 <0.184 <0.187 <0.187 1300 3,600 45,000Benzo(a)anthracene <0.172 0.578 J 0.282 J 0.188 J 0.24 J <0.166 <0.175 <0.174 <0.179 <0.182 <0.182 0.35 1.1 21Benzo(a)pyrene <0.181 0.612 J 0.484 J 0.219 J 0.287 J <0.175 <0.185 <0.184 <0.189 <0.192 <0.192 0.12 0.11 2.1Benzo(b)fluoranthene 0.303 J 1.02 0.755 J 0.307 J 0.374 J <0.174 <0.184 0.221 J <0.188 <0.191 <0.191 1.2 1.1 21Benzo(ghi)perylene 0.173 J 0.501 J 0.546 J <0.166 0.211 J <0.162 <0.171 <0.170 <0.175 <0.178 <0.178 NS NS NSBenzo(k)fluoranthene <0.169 0.292 J 0.236 J <0.168 <0.170 <0.163 <0.172 <0.171 <0.176 <0.179 <0.179 12 11 210Chrysene<0.175 0.535 J 0.221 J 0.213 J 0.246 J <0.169 <0.179 <0.177 <0.182 <0.186 <0.186 36 110 2,100Fluoranthene0.174 J 1.05 0.179 J 0.289 J 0.457 J <0.147 <0.155 0.157 J <0.158 <0.161 <0.161 670 480 6,000Indeno(123-cd)pyrene <0.221 0.62 J 0.65 J <0.219 0.237 J <0.214 <0.226 <0.224 <0.230 <0.234 <0.234 3.9 1.1 211-Methylnaphthalene <0.131 <0.136 <0.134 <0.130 <0.132 <0.126 <0.133 <0.132 <0.136 <0.138 <0.139 0.11 18 732-Methylnaphthalene <0.123 <0.128 <0.126 <0.122 <0.124 <0.119 <0.126 0.141 J <0.128 <0.131 <0.131 3.1 48 600Naphthalene<0.178 <0.184 <0.182 <0.176 <0.179 <0.172 <0.181 <0.180 <0.185 <0.188 <0.188 0.39 2.1 8.8Phenanthrene<0.257 0.794 J <0.263 <0.255 <0.259 <0.248 <0.262 <0.260 <0.268 <0.272 <0.272 NS NS NSPyrene<0.165 0.829 J <0.169 0.278 J 0.373 J <0.160 <0.169 <0.167 <0.172 <0.175 <0.175 440 360 4,500Arsenic2.09 4.2 0.696 21.7 2.98 1.47 0.917 3.17 1.47 0.834 0.768 5.8 0.68 3 100 1.2-2.7 4.1-12.4 0.467-7.5Barium87.9 126 113 175 239 100 58.7 124 46.4 57.5 62.1 580 3,100 47,000 2,000 64-220 37.9-66.3 8.21-192Cadmium0.146 J 0.777 0.0546 J 0.69 0.587 0.0647 J <0.0327 0.573 <0.0333 <0.0339 0.0561 J 3 1.4 20 20 <0.05 0.087-0.24 0.036-0.97Lead52.4 186 18 164 197 40 6.34 99.9 7.07 7.55 15.1 270 400 800 100 6.6-18 12.1-24.9 3.1-107Selenium1.02 0.878 1.01 0.884 0.995 0.872 0.511 0.919 0.782 0.84 1.11 2.1 78 1,200 20 1.2-4.1 1.1-3.5 <0.097-0.85Silver0.0466 J 0.245 J 0.02 J 0.22 J 0.466 0.0728 J 0.0261 J 0.142 J 0.0264 J 0.0211 J 0.0297 J 3.4 78 1,200 100 <0.07 <0.2-0.3 <0.04-0.358Chromium (Total)18.8 22.0 9.99 24.9 34.7 24.8 15.7 23.3 29.0 18.0 15.7 NS NS NS -37-90 21.1-32.8 1.8-103Chromium (Trivalent)18.5 22.0 9.99 24.5 34.3 24.8 15.2 23.0 29.0 18.0 15.7 360000 23000 350000 -35-90 21.1-32.8 1.8-103SW7199Chromium Hexavalent 0.28 <0.181 <0.178 0.422 0.399 <0.168 0.521 0.333 <0.181 <0.184 <0.185 3.8 0.31 6.5 100 0.27-2 <0.319 <2.7-<46.6Chromium TCLP --------------5.0 ---Lead TCLP ---0.079 0.124 ---------5.0 ---7471A Mercury (Total)0.222 J 0.145 J 0.0901 J 1.42 0.496 0.225 <0.0282 0.353 <0.0286 0.0571 J <0.0291 1 2.3 9.7 4 0.037-0.074 0.028-0.053 <0.01-0.35Notes:All concentrations are reported in mg/kg (milligrams per kilogram). Chromium (Trivalent) calculated by subtracting Chromium Hexavalent from Chromium (Total). The Rule of 20 Values are derived from a 1:20 factor of the United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), November 2004, Maximum Concentration of Contaminants for Toxicity Characteristic.NS = No screening level established; - = Not applicableQ = Qualifier; J = Laboratory estimated value below the lowest calibration point/reporting limit; B = Analyte also detected in associated method blankBold = Detection; Bold/Highlight = Exceedance of the PSRG or Rule of 20 Value; Underlined = Exceedance of Protection of Groundwater PSRGItalicized = Exceedance of Old 27 Landfill Background Metal Concentration; Blue = Exceedance of Griffin Farms Landfill Background Metal ConcentrationDUP-1 sampled at EX-8 (2-5'); DUP-2 sampled at EX-1 (0-2') EX-12Sample ID EX-10 EX-112-5'5-10'10-20'04/17/230-2'2-5'5-10'0-2'Protection of Groundwater PSRG Residential PSRG Industrial/ Commercial PSRG Rule of 20/ TCLP Value Old 27 Landfill Background04/18/23Date Collected 04/19/23 0-2'2-5'5-10'10-17.5'Tarmac Virginia - SW6010D 8070E 8260D -- Laboratory analytical results were screened against the North Carolina Department of Environmental Quality (NCDEQ) Health-Based Preliminary Soil Remediation Goals (PSRG), January 2023, Rule of 20 Values, United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), May 2021, and background metals concentrations of Old 27 LCID Landfill (BF No. 20050-16-060), May 2021, Griffin Farms LCID, March 2021, and Tarmac Virginia Brownfields Property (BF No. 26067-22-060), June 2022. Griffin Farms Landfill Background - 6020B ONE Page 4 of 5 AP Foundry, LP EMP Attachment 6.0Summary of Soil Analytical DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina Method Analyte Result Q Result Q Result Q Result Q Result Q Result QAcetone0.024 J 0.149 0.053 0.045 0.009 J 0.038 25 14,000 210,000Benzene<0.0008 <0.0008 <0.0008 <0.0007 <0.0007 <0.0007 0.01 1.2 5.4Carbon Disulfide <0.0008 <0.0009 <0.0008 <0.0008 <0.0008 <0.0008 4.1 160 740n-Hexane <0.0009 <0.0009 <0.0009 <0.0008 <0.0008 <0.0008 55 130 540Methyl Ethyl Ketone (MEK)<0.0008 0.005 J 0.003 J <0.0008 <0.0008 <0.0008 17 5,500 40,000Methylene Chloride 0.002 B J <0.001 0.003 B J 0.001 B J 0.001 B J 0.002 B J 0.025 58 650Toluene<0.0009 <0.0009 <0.0009 <0.0008 <0.0008 <0.0008 8.3 990 9,700Anthracene<0.185 <0.193 <0.186 <0.178 <0.175 <0.183 1300 3,600 45,000Benzo(a)anthracene <0.180 <0.188 <0.180 <0.173 <0.170 <0.178 0.35 1.1 21Benzo(a)pyrene <0.190 <0.199 <0.191 <0.183 <0.179 <0.188 0.12 0.11 2.1Benzo(b)fluoranthene 0.206 J <0.197 <0.190 <0.182 <0.178 <0.187 1.2 1.1 21Benzo(ghi)perylene <0.176 <0.184 <0.177 <0.169 <0.166 <0.174 NS NS NSBenzo(k)fluoranthene <0.177 <0.185 <0.178 <0.171 <0.167 <0.175 12 11 210Chrysene<0.184 <0.192 <0.184 <0.177 <0.173 <0.182 36 110 2,100Fluoranthene0.207 J <0.166 <0.160 <0.153 <0.150 <0.157 670 480 6,000Indeno(123-cd)pyrene <0.232 <0.242 <0.233 <0.223 <0.219 <0.229 3.9 1.1 211-Methylnaphthalene <0.137 <0.143 <0.138 <0.132 <0.129 <0.135 0.11 18 732-Methylnaphthalene <0.129 <0.135 <0.130 <0.124 <0.122 <0.128 3.1 48 600Naphthalene<0.187 <0.195 <0.187 <0.179 <0.176 <0.184 0.39 2.1 8.8Phenanthrene<0.270 <0.281 <0.270 <0.259 <0.254 <0.266 NS NS NSPyrene0.181 J <0.181 <0.174 <0.167 <0.164 <0.171 440 360 4,500Arsenic31.01 0.6 0.714 1.04 1.99 5.8 0.68 3 100 1.2-2.7 4.1-12.4 0.467-7.5Barium70.4 33.5 82 61.3 87.3 96.9 580 3,100 47,000 2,000 64-220 37.9-66.3 8.21-192Cadmium0.174 J <0.0350 0.0444 J 0.0414 J <0.0317 0.201 J 3 1.4 20 20 <0.05 0.087-0.24 0.036-0.97Lead2326.2 7.58 4.98 12.9 83.2 270 400 800 100 6.6-18 12.1-24.9 3.1-107Selenium0.851 0.57 0.834 0.707 0.566 0.621 2.1 78 1,200 20 1.2-4.1 1.1-3.5 <0.097-0.85Silver0.0403 J 0.0173 J 0.0221 J 0.0203 J 0.0181 J 0.112 J 3.4 78 1,200 100 <0.07 <0.2-0.3 <0.04-0.358Chromium (Total)27.5 10.6 41.8 10.9 14.6 151 NS NS NS -37-90 21.1-32.8 1.8-103Chromium (Trivalent)27.5 10.6 41.4 10.9 14.3 150 360000 23000 350000 -35-90 21.1-32.8 1.8-103SW7199Chromium Hexavalent <0.183 <0.191 0.432 <0.176 0.293 1.41 3.8 0.31 6.5 100 0.27-2 <0.319 <2.7-<46.6Chromium TCLP -----<0.012 ---5.0 ---Lead TCLP ---------5.0 ---7471A Mercury (Total)0.07 J 0.215 J 0.0408 J <0.0278 0.0581 J 0.395 1 2.3 9.7 4 0.037-0.074 0.028-0.053 <0.01-0.35Notes:All concentrations are reported in mg/kg (milligrams per kilogram). Chromium (Trivalent) calculated by subtracting Chromium Hexavalent from Chromium (Total). The Rule of 20 Values are derived from a 1:20 factor of the United States Environmental Protection Agency (USEPA) Toxicity Characteristic Leaching Procedure (TCLP), November 2004, Maximum Concentration of Contaminants for Toxicity Characteristic.NS = No screening level established; - = Not applicableQ = Qualifier; J = Laboratory estimated value below the lowest calibration point/reporting limit; B = Analyte also detected in associated method blankBold = Detection; Bold/Highlight = Exceedance of the PSRG or Rule of 20 Value; Underlined = Exceedance of Protection of Groundwater PSRGItalicized = Exceedance of Old 27 Landfill Background Metal Concentration; Blue = Exceedance of Griffin Farms Landfill Background Metal ConcentrationDUP-1 sampled at EX-8 (2-5'); DUP-2 sampled at EX-1 (0-2') Industrial/ Commercial PSRG Rule of 20/ TCLP ValueSample ID EX-130-2'2-5'5-10'10-20'Old 27 Landfill BackgroundSB-1 SB-2 Protection of Groundwater PSRG Residential PSRG04/18/23Date Collected SW6010D -- 8070E 8260D Laboratory analytical results were screened against the North Carolina Department of Environmental Quality (NCDEQ) Health-Based Preliminary Soil Remediation Goals (PSRG), January 2023, Rule of 20 Values, United States Environmental Protection Agency (USEPAbackground metals concentrations of Old 27 LCID Landfill (BF No. 20050-16-060), May 2021, Griffin Farms LCID, March 2021, and Tarmac Virginia Brownfields Property (BF No. 26067-22-060), June 2022. Tarmac Virginia - Griffin Farms Landfill Background - 6020B ONE Page 5 of 5 AP Foundry, LP I I I I I I I I I I I I I I I I I I I Revision April 11, 2013 Date: ~--~ EPA 8260 (mg/kg) .. C~qtclit ..... .. ., ., ., c c: c "O ., i!l "" . ·' "· .1:.;.·. ., N 31 ., 1.· ., N c: c c ·.·. ·:: .. ·,< ... ,A·.--·"'' c: c .. " "' Q) 1l <II .· ·: \~-.9 "' ~ "' :;:, ~ c I·· "' ~ ·c· 0 :; c: 9 < " ~ Ill 0 ~~ Q. ~ &l i -e ., <II (.) ... GP-1-15 3/1/2013 TW-1 15 BRL 0.0073 0.024 0.0045 BRL BRL GP-2-7.5 3/1/2013 TW-2 7.5 0.085 BRL BRL BRL BRL BRL GP-3-25 3/1/2013 TW-3 25 0.072 BRL BRL BRL BRL BRL s-1* 7/26/2012 GP-1 4 BRL BRL 2.3 BRL BRL 1.3J s-2* 7/26/2012 GP-2 6 0.059 BRL 0.011 0.0016 J 0.0016J 0.0028 J S-3* 7126/2012 GP-5 8 BRL BRL BRL BRL BRL BRL S-4* 7/26/2012 GP-3 12 0.035 BRL BRL BRL BRL BRL s-s* 7/26/2012 GP-4 10 0.0073J BRL BRL BRL BRL BRL s-e* 7/26/2012 GP-6 6 BRL BRL BRL BRL BRL BRL S-7* 7126/2012 GP-7 8 0.012 J BRL BRL BRL 0.0025J BRL s-a* 7/26/2012 GP-8 6 BRL BRL 0.22J BRL BRL BRL - 24 2.4 2.2 1.7 3.8 NL 12,000 110 NL NL 160 NL 100,000 110 NL NL 740 NL Notes: * -Sample Collected/Reported By Other Consultant BRL -Below Reporting Limit J -Detected At Concentration Below Reporting Limit, Result Is An Estimated Concentration NA -Not Analyzed NL -Not Listed Q) " c Q) c: N .. c N .. c: "' "' :;:, "' :;:, Q. e = w Q. ii BRL 0.019 BRL BRL BRL BRL 1.5J 4.6 BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL 8.1 1.3 5.4 270 27 270 PSRG -Inactive Hazardous Sites Branch Preliminary Soil Remediation Goal (From Table Dated January 2012) Yellow Shaded Cells Exceed Protection Of Groundwater PSRG Orange Shaded Cells Exceed Residential Health Based PSRG Pink Shaded Cells Exceed Commercial/Industrial Health Based PSRG ., c 0 Qj :<'. :;:, .s:; ii:i :;:, ~ :; BRL 0.0059J 0.0078J BRL 0.0082J BRL BRL BRL BRL BRL BRL 16 5,600 28,000 Table 1: .. .. c: c: .. i!l " N c: c c: "' i!l c "' "' ., "' "' c :;:, :;:, iii ., = .s:; ~ "' Qj :;:, ., Q. Q. E E e ., ·c ·c: z C\-f-f-.... "' c: <'i "! ~ ~ 0.038 0.024 BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL • ·->;' 24 •• 48 0.0096 BRL 0.0025J BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL 1.1 0.11 J 0.19J BRL 0.21 1.5 6.7 6.7 3.6 260 12 160 18 260 52 180 Summary of Soil Sampling Results EPA 8270 (mg/kg) " .. .. ., ., ., c: c c c c: c: "' .. .. .. 'l': I ., .. Q) ., = = ~ c c: ., iii iii "' ., " c: ., 0 11\"' c: c: !';! c c ., ~ ~ !';! c = = c ., ., ., ., c !';! !';! Q. ,., .s=-., ., .91 ~ "' c: c ~ Q) = >..!!! '€ ~ c ~~ .s:; .s:; .. :;:, 0 0 0 ,!!: ~ Q. Q. ., ~ c: .. c ~ ~., ~ " :;:, >i: Q. !';! .lll " " .c .. = .. N !';! 0 ~~ .. .. ~ ~ >i: .. !E. !E. 2 cp: c: " 0,., c ~ .. 6: Q. ~ ~ .. "' -" .§ N.s:; .s:; "' 0 ;:;:: c: Q. :;:, Q. c: 0 oil 2 (.) .0 " .s:; .s:; .. ., 2 'O' c: ~ Q. ., .s:; E < N 2 ~ <II c ;:;:: "O Qj Qj z tl. c: c ~ c iii .s =ii ~ ~ "' .. Ill Ill - BRL BRL BRL 0.26 J BRL BRL BRL BRL BRL BRL BRL BRL 0.23J BRL 0.65 BRL 2.3 3.2 0.32J 1.3 0.14J BRL BRL BRL NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA BRL BRL BRL NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA NA 0.89J 2.5J 5.9 BRL BRL 0.25J o.37J 0.13J BRL ~~ . 1.7 0.64 BRL 0.58 BRL BRL BRL BRL 0.57 BRL 0.32J BRL BRL BRL BRL 2.1 J .:.~: : ~" ··. 2.5J 3.3J BRL BRL 3.2J BRL 5.1 BRL 3i&.S BRL BRL BRL 2.2J 4.0 .. BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL BRL 0.S6J 0.94J BRL ~ BRL 0.52J BRL 2.0J BRL BRL BRL BRL BRL BRL 0.92J 5.5 NL NL 8.4 660 0.18 0.6 5.9 7,800 0.059 7.2 18 5.2 330 56 2.0 0.055 1.6 0.21 68 220 820 140 120 680 3,400 0.15 0.15 1.5 NL 0.015 35 15 16 460 460 0.15 16 46 3.6 NL 340 820 430 390 6,600 34,000 2.1 2.1 21 NL 0.21 120 210 170 4,400 4,400 2.1 53 370 18 NL 3,400 EMP Attachment 6.1Summary of Historical Soil Analytical DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina EMP Attachment 6.2Summary of Groundwater Analytical DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina Method Analyte Result Q Result Q Result Q Result Q Result Q Result Q Result QAcetone15.6 <1.80 <1.80 <1.80 <1.80 <1.80 <1.80 6,000 6,000,000Carbon Disulfide <0.150 <0.150 <0.150 <0.150 0.661 J <0.150 <0.150 700 590,000cis-12-Dichloroethene <0.200 0.5 0.489 J 0.362 J 0.518 0.363 J <0.200 70 70,000Methyl Ethyl Ketone (MEK)1.19 J <0.710 <0.710 <0.710 <0.710 <0.710 <0.710 4,000 4,000,000Tetrachloroethene<0.220 <0.220 0.225 J <0.220 <0.220 <0.220 <0.220 0.7 700Toluene<0.220 <0.220 <0.220 <0.220 0.331 J <0.220 <0.220 600 260,000Trichloroethene1.01 71.5 68 83.4 2.63 45.2 <0.180 3 3,000Diethyl phthalate 0.868 J H <0.749 <0.752 <0.752 <0.585 H 6,000 NSDimethyl phthalate 3.81 J H <0.944 <0.948 <0.948 <0.510 H NS NSBarium41.3 21.3 22.1 20.2 90.2 700 700,000Chromium3.74 1.09 1.14 2.12 0.427 J 10 10,000Lead0.561 J <0.264 <0.264 <0.264 0.288 J 15 15,000Selenium0.719 J 1.51 1.48 1.04 <0.703 20 NSSM-3500CrB Chromium Hexavalent <0.0044 <0.0044 <0.0044 <0.0044 <0.0044 NS NSSW-7470A Mercury <0.00013 <0.00013 <0.00013 <0.00013 <0.00013 1 NSNotes:All concentrations are reported in µg/L (micrograms per liter). NS = No screening level established- = Not analyzedQ = Qualifier; J = Laboratory estimated value below the lowest calibration point/reporting limit; H = Sample analyzed outside of hold timeBold = DetectionBold/Highlight = Exceedance of a regulatory screening level 2L GCLMW-4 IDW-1 Trip Blank Laboratory analytical results are screened against the North Carolina Department of Environmental Quality (NCDEQ) 15A NCAC 02L .0202 Groundwater Quality Standards (2L) (2022) and Gross Contamination Levels for Groundwater (GLC) (2014). Sample IDDate Collected 04/17/23 SW-6020B MW-1 MW-2 DUP-1 MW-3 SW-8260D SW-8270E - ONE Page 1 of 1 AP Foundry, LP MethodAnalyteResult Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q1,1,1-Trichloroethane <5.5 <5.5 <5.5 <5.5 <5.5 <5.5 <5.5 <5.5<5.5 <5.5 <5.544,0001,1,2-Trichloroethane<5.5 <5.5 <5.5 <5.5 <5.57.1<5.5 <5.5 <5.5 <5.5 <5.5181,1-Dichloroethane <4.0 <4.0 <4.0 <4.0 <4.0 <4.0 <4.0 <4.0 <4.0 <4.0 <4.07701,1-Dichloroethene <4.0 <4.0 <4.0 <4.0<4.0 <4.0 <4.0 <4.0<4.0 <4.0 <4.018,0001,2,4-Trimethylbenzene <4.9 <7.4 <4.9 <7.43.4J12<7.4 <7.4134.2J6.95,3001,3,5-Trimethylbenzene <4.9 <4.9 <4.9 <4.9 <4.93.4J <4.9 <4.93.2J <4.9 <4.95,3001,3-Butadiene <2.2 <2.2 <2.2 <2.2 <2.2 <2.290<2.28.3153.4412,2,4-Trimethylpentane <4.7 <4.7 <4.7 <4.7 <4.7140<4.7 <4.72.8J <4.7 <4.7NS2-Butanone262.4J12146.913128.4121515440,0002-Hexanone <4.1 <4.1 <4.1 <4.1 <4.1164.9<4.13.9J <4.13.5J 2,6004-Ethyltoluene <4.9 <4.9 <4.9 <4.9 <4.92.9J <4.9 <4.94.2J <4.9 <4.9NS4-Methyl-2-pentanone17<4.1182115103.7J4.3423575260,000Acetone260<247478284608429759949NSBenzene<3.2 <3.2 <3.2 <3.2813124.35.33.75.4160Bromodichloromethane <5.2 <6.7 <6.7 <6.7 <6.716<6.7 <6.7 <6.7 <6.7 <6.733Carbon disulfide1.7J <3.13.753.450326.2389.32361,000Chlorobenzene <4.6 <4.6 <4.6 <4.6 <4.63.0J <4.6 <4.615<4.6 <4.64,400Chloroform <4.9 <4.9 <4.9 <4.9 <4.95.4<4.9 <4.9 <4.9 <4.9 <4.953Chloromethane <2.1 <2.12.22.2<2.11.8J <2.1 <2.1 <2.1 <2.1 <2.17,900cis-1,2-Dichloroethene <4.0 <4.0 <4.0 <4.0 <4.0260<4.0 <4.0 <4.0 <4.0 <4.03,500Cyclohexane10<3.48.68.854130662226078110530,000Dichlorodifluoromethane <4.93.5J<4.9 <4.9 <4.9 <4.9<4.9 <4.9 <4.9 <4.97.48,760Ethylbenzene <4.3 <4.3 <4.3 <4.32.40J6.13.9J3.3J14059.1490Isopropyl alcohol4.9J <18 <185.4J <184.4J <18 <18 <18 <18 <1818,000m,p-Xylene <8.7 <8.7 <8.7 <8.75.0J136.1J8.797011178,800Methylene chloride <3.5 <3.5 <3.5 <3.5<3.5 <3.5 <3.5 <3.5<3.5 <3.5 <3.553,000n-Heptane<4.1 <4.1 <4.1 <4.1 <4.13317<4.16.4<4.13.9J 35,000n-Hexane<3.5 <4.14.8<3.53.911050<3.520106.961,000o-Xylene<4.3 <4.3 <4.3 <4.3 <4.35.92.8J4.1J4804.1J5.48,800Propene1.9<1.71.92.57.6 2,200 1,800 13200 42021260,000Styrene<4.3 <4.3 <4.3 <4.3 <4.31.7J <4.3 <4.34.0J <4.32.8J 88,000Tetrachloroethene4,000 29<6.8 <6.818<6.8 <6.8 <6.8 <6.8 <6.8 <6.83,500Tetrahydrofuran8.4<2.9 <2.9 <2.9 <2.9 <2.9 <2.9 <2.94.45.34.3180,000Toluene6.24.11111271102949250 120 180440,000trans-1,2-Dichloroethene <4.0 <4.0 <4.0 <4.0 <4.012<4.0 <4.0 <4.0 <4.0 <4.03,500Trichloroethene <5.4 <5.42121<5.4660<5.4 <5.4 <5.420<5.4180Trichlorofluoromethane <5.6 <5.6 <5.63.1J <5.6 <5.6 <5.6 <5.6 <5.6 <5.6 <5.6NSVinyl acetate <3.5 <3.5 <3.5 <3.5 <3.5 <3.5 <3.5 <3.5 <3.5 <3.5 <3.518,000Xylenes, Total <13 <13 <13 <13 <13198.9J13J1,400 15228,800Notes:All concentrations are reported in micrograms per cubic meter (µg/m3).Sub-slab and exterior soil gas screening levels (SGSLs) were obtained from the North Carolina Department of Environmental Quality (NCDEQ) Vapor Intrusion Risk Calculator using the non-residential exposure scenario.For each sample, a cumulative exceedance exists when the carcinogenic risk exceeds 1.0E-06 or the hazard quotient exceeds 1.0. Compounds 2,2,4-trimethylpentane and 4-ethyltoluene were not identified in the NCDEQ Vapor Intrusion Risk Calculator and are not included in risk calculations.NS = No screening level established; NA = Not applicableQ = Qualifier; J = Laboratory estimated value below the lowest calibration point/reporting limitBold = DetectionBold/Highlight = Exceedance of a regulatory screening levelElevatorParking garageSoil Characterization ZoneNAEX-1Retail RetailSample Location (Future use- 1st floor)RetailRetailConcrete drive RetailSample Location (Current use)623 South Cedar StreetEX-2Cumulative Exceedence TO-15Sample IDDate CollectedSS-1 SS-2 SS-3 DUP-2 SS-4 SG-1 SG-2 SG-3 SG-4 SG-5 SG-6623 South Cedar StreetGrass hillsideDirt drive600 Eldridge StreetAsphalt parking lotGrass medianAsphalt parking lotNoSub-Slab and Exterior SGSLEX-3EX-4Stairwell04/19/23NoNoNoNoNoNoNoNoYesYesONEPage 1 of 2AP Foundry, LPEMP Attachment 6.3Summary of Sub-Slab and Exterior Soil Gas Analytical Data Mill Creek - Dynamic Auto Works II and FoundryCharlotte, North Carolina EMP Attachment 6.3Summary of Sub-Slab and Exterior Soil Gas Analytical Data Mill Creek - Dynamic Auto Works II and FoundryCharlotte, North CarolinaMethodAnalyteResult Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q Result Q1,1,1-Trichloroethane <5.5 <5.5 <5.5 <5.56.8<5.517<5.5 <5.5 <5.5 <5.5 <5.544,0001,1,2-Trichloroethane <5.5 <5.5 <5.5 <5.5 <5.5 <5.5 <5.5 <5.5 <5.5 <5.5 <5.5 <5.5181,1-Dichloroethane <4.0 <4.0 <4.0 <4.0 <4.0 <4.03.2J <4.0 <4.0 <4.0 <4.0 <4.07701,1-Dichloroethene <4.0 <4.0 <4.0 <4.0 <4.0 <4.06.3<4.0 <4.0 <4.0<4.0 <4.018,0001,2,4-Trimethylbenzene <7.420<7.4 <7.4 <7.4 <7.4 <7.48.84.4J <7.43.7J3.9J 5,3001,3,5-Trimethylbenzene <4.95.7<4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.95,3001,3-Butadiene <2.24.8<2.2 <2.2 <2.2 <2.2 <2.211012<2.2 <2.2 <2.2412,2,4-Trimethylpentane <4.7<4.7 <4.7 <4.7 <4.7 <4.7 <4.74.7<4.7 <4.7 <4.7 <4.7N/A2-Butanone5.6413.26.55.3121315133.42827440,0002-Hexanone <4.1 <4.1 <4.13.5J <4.13.7J <4.14.5<4.1 <4.1 <4.12.7J 2,6004-Ethyltoluene <4.96.6<4.9 <4.9 <4.9 <4.9 <4.93.4J <4.9 <4.9 <4.9 <4.9N/A4-Methyl-2-pentanone2.5J95<4.1 <4.15.1<4.15.5356.62.3J100 140260,000Acetone6021010J <2414J44531608012J150 140N/ABenzene117<3.213<3.22.9J3.5155.82.6J2.4J <3.2160Bromodichloromethane <6.7 <6.7 <6.7 <6.7<6.7 <6.7 <6.7 <6.7 <6.7 <6.7 <6.7 <6.733Carbon disulfide9.8342.2J6.2<3.16.97.2666.23.79.81161,000Chlorobenzene <4.6 <4.6 <4.62.8J <4.6 <4.6 <4.6 <4.6 <4.6 <4.6 <4.6 <4.64,400Chloroform <4.9 <4.9 <4.9 <4.99.8<4.918<4.9<4.9 <4.9 <4.9 <4.953Chloromethane <2.1 <2.1 <2.1 <2.1 <2.1<2.1 <2.1 <2.1 <2.1<2.1 <2.1 <2.17,900cis-1,2-Dichloroethene <4.0 <4.0 <4.0 <4.0 <4.0 <4.0140<4.0 <4.0 <4.0 <4.0 <4.03,500Cyclohexane652.8J854916<3.423240 180465255530,000Dichlorodifluoromethane3.7J <4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.9 <4.98,760Ethylbenzene9.3114.319<4.3 <4.33.0J115.22.6J4.1J4.8490Isopropyl alcohol <1821<18 <186.6J <183.6J5.0J4.2J4.2J3.3J <1818,000m,p-Xylene34423.9J41<8.7 <8.75.0J20114.6J10118,800Methylene chloride <3.5 <3.5 <3.5 <3.5 <3.5 <3.55.6<3.5 <3.5 <3.5<3.5 <3.553,000n-Heptane3.3J4.3<4.15.1<4.14.5<4.119<4.1 <4.1 <4.1 <4.135,000n-Hexane778.8<3.544<3.5114.863103.2J4.13.2J 61,000o-Xylene1912<4.334<4.3 <4.3 <4.37.86.54.1J3.5J3.7J 8,800Propene3,000 4616440121041 3,100 170544.75.7260,000Styrene<4.32.6J <4.32.1J <4.3 <4.3 <4.32.3J <4.3 <4.3 <4.3 <4.388,000Tetrachloroethene <6.8 <6.8 <6.82874038 2,800<6.8 <6.8 <6.8 <6.8 <6.83,500Tetrahydrofuran <2.913<2.9 <2.92.2J <2.9 <2.98.44<2.954.4180,000Toluene575703728136.2254407326110 110440,000trans-1,2-Dichloroethene <4.0 <4.0 <4.0 <4.0 <4.0 <4.04.6<4.0 <4.0 <4.0 <4.0 <4.03,500Trichloroethene <5.4 <5.411650 5204.8J3,100<5.44.0J7<5.4 <5.4180Trichlorofluoromethane <5.6 <5.6 <5.617<5.6 <5.63.9J <5.6 <5.6 <5.6 <5.6 <5.6N/AVinyl acetate <3.5 <3.5 <3.5 <3.5 <3.5 <3.5 <3.520<3.5 <3.5 <3.5 <3.518,000Xylenes, Total5354<1375<13 <13 <132818<1314158,800Notes:All concentrations are reported in micrograms per cubic meter (µg/m3).Sub-slab and exterior soil gas screening levels (SGSLs) were obtained from the North Carolina Department of Environmental Quality (NCDEQ) Vapor Intrusion Risk Calculator using the non-residential exposure scenario.For each sample, a cumulative exceedance exists when the carcinogenic risk exceeds 1.0E-06 or the hazard quotient exceeds 1.0. Compounds 2,2,4-trimethylpentane and 4-ethyltoluene were not identified in the NCDEQ Vapor Intrusion Risk Calculator and are not included in risk calculations.NS = No screening level established; NA = Not applicableQ = Qualifier; J = Laboratory estimated value below the lowest calibration point/reporting limitBold = DetectionBold/Highlight = Exceedance of a regulatory screening levelSub-Slab and Exterior SGSLSample Location (Current use)SG-17EX-13Dirt RoadRestaurant/Parking garageRetail/Lobby/Parking garageDUP-1SG-9 SG-10 SG-11 SG-12 SG-13Dirt ParkingParking garageGrass AreaYesYesYesYesNoNoNoSG-14 SG-15 SG-16SG-7 SG-8Sample IDDate CollectedExterior vacant shopSoil Characterization ZoneSample Location (Future use- 1st floor)EX-5 EX-7 EX-8EX-9EX-10EX-11EX-12TO-15Cumulative Exceedence 04/19/23NoNoNoNoNoONEPage 2 of 2AP Foundry, LP Revision Date Method T0-15 Noles: July2, 2014 Chent Sample ID Collect Date Compound cis-1,2· Dichloroethene trans-1,2- Dichloroelhene Trichloroethylene ITC El Vinvt chloride N/A NL Air-1 Units 6/26/2014 µg/m3 <0.79 µg/m3 <0.79 µg/m3 <1.1 µQ/m3 <0.51 -Not Applicable ·Not Listed Air-2 6/26/2014 <0.79 <0.79 <1.1 <0.51 Table 2: Summary of Indoor Air Sampling Results Air-3 Aif-4 DWM Residential Indoor Air and Crawlspace Screening Level (June 2014) IASLIAl IASLIBl IASL© 6/26/2014 6/26/2014 TCR = 1.0E-06 TCR = 1.0E-05 TCR = 1.0E·04 <0.79 <0.79 NL NL NL <0.79 <0.79 NL NL NL <1.1 <1.1 0.42 0.42 0.42 <0.51 <0.51 0.17 1.7 16.8 • Exceeds DWM Residential Vapor Intrusion Screening Levels • Exceeds DWM Industrial/Commercial Vapor Intrusion Screening Levels DWM Commercial/Industrial Indoor Air and Crawlspace Screening Level (June 2014) IASLIAl IASLIBl IASL© TCR = 1.0E-06 TCR = 1.0E·05 TCR = 1.0E-04 NL NL NL NL NL NL 1.75 1.75 1.75 2.8 27.9 87.6 P:\Work Files\ENV\2013\014 ·South Cedar\Data tor 7-1 Report\NewVapor and Indoor Samples 6_27_14 Page 1 EMP Attachment 6.4Summary of Historical Indoor Air Analytical DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina EMP Attachment 7.0Summary of Groundwater Elevation DataMill Creek - Dynamic Auto Works II and Foundry Charlotte, North Carolina Monitoring Location ID Gauging Date Depth to Water (ft btoc)Depth to Bottom (ft btoc)Top of Casing Elevation(ft amsl)Groundwater Elevation(ft amsl)MW-1 4/17/2023 26.77 30.14 670.77 644.00MW-2 4/17/2023 22.91 37.01 669.52 646.61MW-3 4/17/2023 26.02 42.55 676.40 650.38MW-4 4/17/2023 15.17 19.50 657.61 642.44Notes:Elevations estimated using Google Earth Pro 2023ft btoc = Feet Below Top of Casing; ft amsl = Feet Above Mean Sea Level ONE Page 1 of 1 AP Foundry, LP