Loading...
HomeMy WebLinkAbout25022_SouthBank Bldg_Asbestos Rpt_20210611Ift Mid Atlantic NESHAP Acbesteca Survey Report Former South Bank 400 West Main Street Durham, Durham County, North Carolina PREPARED FOR - Austin Lawrence Partners 400 West Main Street, Suite 100 Durham, North Carolina, 27701 PREPARED BY: Mid -Atlantic Associates 409 Rogers View Court Raleigh, North Carolina, 27610 a Mid Atlantic Engineering & Environmental 5aiutidris June 11, 2021 Mr. Austin Hills Austin Lawrence Partners 400 West Main Street, Suite 100 Durham, North Carolina 27701 Subject: NESHAP Asbestos Survey Report Former South Bank 400 West Main Street Durham, Durham County, North Carolina Mid -Atlantic Project No. 0001113710.00 Task No. 07500 Dear Mr. Hills: 109 Rogers View Court Raleigh. NC 27510 office I19.I50.9918 facsimife 919.I50.9950 MAAONLINE.COM Mid Atlantic Associates, Inc. (Mid -Atlantic) was contracted by Austin Lawrence Partners to conduct a National Emissions Standards for Hazardous Air Pollutants (NESHAP) asbestos survey of the commercial building located at 400 West Main Street in Durham, Durham County, North Carolina. The NESHAP asbestos survey was completed as part of future planned demolition activities at the Subject Property. Asbestos was identified during this survey. Mid -Atlantic appreciates the opportunity to provide our services on this project. Please do not hesitate to contact us if you have any questions or comments. Sincerely, MID -ATLANTIC ASSOCIATES, INC Gareth Hoffmann Darin M. McClure, P.E. Field Industrial Hygienist Principal Engineer N.C. Asbestos Inspector No. 13054 N.C. Asbestos Inspector No. 11115 EXPERIENCED CUSTOMER FOCUSED INNOVATIVE TABLE OF CONTENTS 1.0 INTRODUCTION.................................................. 1 2.0 DEFINITIONS.................................................... 1 2.1 Asbestos -Containing Material .................................... 1 2.2 Building Asbestos Survey ....................................... 2 2.3 Pre -Construction Survey ........................................ 2 3.0 DESCRIPTION OF BUILDINGS ...................................... 2 4.0 FIELD ACTIVITIES ................................................ 3 4.1 Visual Assessment ............................................ 3 4.2 Physical Assessment..........................................3 4.3 Sample Collection ............................................. 3 4.4 Sample Analysis .............................................. 3 5.0 FINDINGS AND RECOMMENDATIONS ............................... 4 6.0 REGULATORY OVERVIEW ......................................... 6 7.0 ABATEMENT SERVICE COSTS AND RECOMMENDATIONS .............. 7 8.0 LIMITATIONS....................................................7 DRAWINGS Drawing 1 - Site Map Drawing 2 - Basement Asbestos -Containing Sample Location Map Drawing 3 - First Floor Asbestos -Containing Sample Location Map Drawing 4 - Second Floor Asbestos -Containing Sample Location Map Drawing 5 - Third Floor Asbestos -Containing Sample Location Map Drawing 6 - Fourth Floor Asbestos -Containing Sample Location Map Drawing 7 - Fifth Floor Asbestos -Containing Sample Location Map Drawing 8 - Sixth Floor Asbestos -Containing Sample Location Map Drawing 9 - Seventh Floor Asbestos -Containing Sample Location Map APPENDIX A - ASBESTOS SURVEY FORMS AND ANALYTICAL RESULTS APPENDIX B - LABORATORY ANALYTICAL DATA APPENDIX C - PHOTOGRAPHS OF ASBESTOS -CONTAINING MATERIALS APPENDIX D - NORTH CAROLINA ASBESTOS INSPECTOR CERTIFICATIONS IS Mid Atlantic siI'k1:0]Bill" I[s]PI Mid -Atlantic Associates, Inc. (Mid -Atlantic) conducted a National Emissions Standards for Hazardous Air Pollutants (NESHAP, Environmental Protection Agency (EPA) regulation 40 CFR 61, Subpart M) asbestos survey of the commercial building located at 400 West Main Street in Durham, Durham County, North Carolina. A Site Map is provided as Drawing 1. The objective of our scope of services was to identify the potential presence of asbestos containing materials (ACM) at the Subject Property. The asbestos survey was completed as part of future planned demolition activities at the Subject Property. f+��>•114a10I10Is] P69 2.1 Asbestos-Containina Material Friable: Friable asbestos -containing material (ACM) is defined by the Asbestos NESHAP as any material containing more than one percent (>1 %) asbestos as determined using Polarized Light Microscopy (PLM) analysis or equivalent NESHAP approved methods, that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Non -friable: Non -friable ACM is any material containing >1 % asbestos as determined using PLM analysis or equivalent NESHAP approved methods, that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. EPA also defines two categories of nonfriable ACM, Category I and Category II. Category I non -friable ACM includes packings, gaskets, resilient floor coverings, and asphalt roofing products. Category 11 includes any material other than those included in Category I which do not meet the definition of friable. Regulated Asbestos -Containing Material: Regulated Asbestos -Containing Material (RACM) is categorized as friable ACM, Category I nonfriable ACM that has become friable, Category I nonfriable ACM that will be or has been subjected to sanding, grinding, cutting or abrading, or Category II nonfriable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation operations. Trace (<_1 %) Asbestos Containing Material: Materials that contain :51 % asbestos are not considered "asbestos -containing material" under the NESHAP standard; however, materials containing :51 % asbestos are covered by the Occupational Safety and Health Administration's (OSHA's) asbestos construction standard (29 CFR 1926.1101). PLM Point -Count: When a friable or non -friable asbestos -containing material is estimated to contain less than 10 percent asbestos by a method other than point counting, such as visual estimation, the EPA recommends that the determination be repeated using point IS Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 2 counting techniques with PLM. Where binders or like materials are present, appropriate sample preparation methods such as gravimetric reduction must be followed to eliminate the effects of interfering substances. Non -friable Organically Bound: Five bulk materials have been categorized by the EPA that are very difficult to analyze by Polarized Light Microscopy (PLM). These materials are dominantly non -friable and fall into the following categories: Vinyl material (i.e. floor tiles, sheetings), viscous matrix products (i.e. caulks/sealants, adhesives, coatings, joint compound/spackle), cementitious material (i.e. pipes, sheetings), asphaltic roofing materials (i.e. shingles, roof rollings), and miscellaneous products (i.e. frictions plates, gaskets). The EPA recommends that these materials be analyzed by Transmission Electron Microscopy (TEM) when PLM results are inconclusive (EPA600/R-93/116, Appendix D). 2.2 Building Asbestos Survey Building Asbestos Survey: An asbestos survey is an activity performed to determine the presence, location, condition, and estimated quantity of ACM in a building or facility. 2.3 Pre -Construction Su Pre -Construction Survey: A Pre -Construction survey is performed in anticipation of renovation or demolition where a baseline survey has not been conducted, and there is no information, or insufficient information, as to the existence of ACM within the planned limits of construction. The Pre- Construction Survey requires destructive testing if concealed spaces are to be breached during construction. If ACM is found, a Project Design Survey is conducted to provide information for preparing the plans and specifications. The Pre -Construction Survey satisfies the EPA NESHAP requirements for renovation or demolition to "thoroughly inspect the affected facility" or the requirements of governmental agencies for issuance of a building permit. 1;1 11 11 *ffj N121191 Z [97 2 11J f4 Q1010-? A commercial building is located on the Subject Property. According to the Durham County Geographic Information System (GIS), the commercial building on the Subject Property was built in 1973. The commercial structure is an approximately 75,000 square foot, seven -story building with a basement parking deck. The commercial building consists of concrete slab construction. Walls are concrete masonry unit (CMU) with pebbledash exterior finish and plaster and wallboard interior finishes. The roof is flat and is finished with asphaltic built-up roof (BUR) membrane. IS Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 3 El91 •a1=111IN-ITOI W k011*1 The field work for the NESHAP asbestos survey was conducted by Mr. Gareth M. Hoffmann (North Carolina Asbestos Building Inspector Accreditation No. 13054) from May 17, 2021 through May 19, 2021. The survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763, Asbestos Hazard Emergency Response Act (AHERA). A summary of survey activities is provided below. 4.1 Visual Assessment Mid -Atlantic's survey activities began with a visual observation of the commercial building to identify apparent homogeneous areas (HA) of suspect ACM. An HA consists of building materials that appear similar throughout in terms of color, texture, and date of application. The asbestos survey was performed on visually accessible areas on the interior, exterior, and roof of the building. Building materials identified as concrete, glass, wood, masonry, metal or rubber are not considered suspect ACM. 4.2 Phvsical Assessment A physical assessment of each homogeneous area of suspect ACM was conducted to investigate the friability and condition of the materials. A friable material is defined by the EPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials. CWgRlrl T•7W9611154490 Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA protocols. Random samples of suspect materials were collected in each homogeneous area. After collection, samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker. Sample locations were then recorded in the field in order to identify the locations of ACM once the laboratory results were generated. The Asbestos -Containing Sample Location Maps are provided as Drawings 2 - 9. During the asbestos assessment, we collected 168 bulk samples of suspect ACM from 57 HAs. The Asbestos Survey Forms and Analytical Results are included as Appendix A. 4.4 Sample Analysis Suspect ACM samples were submitted under chain of custody control to the Eurofins CEI (CEI) in Cary, North Carolina for analysis. The suspect ACM samples were analyzed by Polarized Light Microscopy (PLM) with dispersion staining techniques per EPA methodology (40 CFR 763, Subpart F). The percentage of asbestos, where applicable, was determined by microscopical visual estimation. CEI is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP Accreditation No. 101768-0). 10 Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 4 Asbestos was identified in 35 of the samples and 12 of the HA's collected from the commercial building on the Subject Property during this investigation. A comprehensive list of building materials sampled, locations, friability, and estimated quantities can be found in the Asbestos Survey Form and Analytical Results included as Appendix A. Samples identified as containing >1 % asbestos are bolded and shaded grey. A copy of the CEI analytical report is included in Appendix B. The photographs of ACM found during this investigation are included in Appendix C. A copy of the North Carolina Asbestos Inspector's Certification is included in Appendix D. F �>•aIzIQIz[c3+y_10117:7x0101LylILi1401B7_A1[910&1 Asbestos -containing materials identified during the asbestos survey at the Subject Property include: Homogeneous Material Sample Location Condition/ Quantity Friability 12"x12" Grey with Black Hallway Electrical/ and White Streak Floor Storage Closet of First, Good/ —343 Square Tile and Black Mastic Second, Third, Fourth, Non -Friable Feet (HA-7) Fifth, Sixth, and Seventh Floors 12"x12" Light Grey Floor Basement Stairwell Tile and Black Mastic Foyers and Second Good/ —936 Square (HA-4) Floor Server Room Non -Friable Feet Suite 203 12" x 12" Off-white with Second Floor Closet Pink Streaked Floor Tile Near Southeast Short Good/ —109 Square and Black Mastic Stairs Non -Friable Feet (HA-32) 12" x 12" Orange and Brown Trowel -Patterned Floor Tile and Black First Floor Suite 103 Good/ — >324 Square Mastic Under Carpet and Storage Room Non -Friable Feet Tan Glue (HA-20) 12"x12" Pink/Brown Both Main Stairwells of Streaked Floor Tile and Basement, First, Good/ —806 Square Black Mastic Second, Third, Fourth, Non -Friable Feet (HA-1) Fifth, Sixth, and Seventh Floors 0 Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 5 Homogeneous Material Sample Location Condition/ Quantity Friability 12"x12" Tan with White Hallway Janitorial Streaked Floor Tile and Closet of First, Second, Good/ —245 Square Black Mastic Third, Fourth, Fifth, Non -Friable Feet (HA-24) Sixthand Seventh , Floors 12" x 12" White Floor Tile and Black Mastic Under Fourth Floor Suite 401 Good/ — >588 Square Carpet and Yellow Mastic and 404 Non -Friable Feet (HA-44 ) Black Mastic/Tar Coating Above Ceiling Tile on on 8" Fiberglass Pipe Second Floor Good/ TBD Elbows (Visualized Above Non -Friable (-10 Elbows) (HA-33) Ceiling Tile on Additional Floors) Black Mastic Associated with 12" x 12" Brown/Tan/ Fourth Floor of Suite Good/ >100 Square Light Brown Blotched 409 Breakroom/Kitchen Non -Friable Feet Floor Tile and Tan Mastic (HA-42) Black Mastic Associated with 12" x 12" Tan Floor Tile Under Carpet and First Floor Suite 103 Good/ >120 Square Yellow Glue Non -Friable Feet (HA-34) Both Main Stairwells of Brown Stair Tread Basement, First, Good/ —2,000 Square (HA-6) Second, Third, Fourth, Non -Friable Feet Fifth, Sixth, and Seventh Floors Both Main Stairwells of Popcorn Wall Texture Basement, First, �12,000 Square (HA-2) Second, Third, Fourth, Good/ Friable Feet Fifth, Sixth, and Seventh Floors Asbestos -containing popcorn wall texture was observed in both stairwells from the basement to the seventh floor during the asbestos survey. Due to the friable nature, quantity, and removal techniques used for removal of popcorn texture, asbestos fibers may be released into the environment if not handled properly. Asbestos -containing floor tile and black mastic was observed in various locations throughout each floor of the building including janitors closets, electrical closets, stairwells, and offices during 0 Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 6 the asbestos survey. Heavily carpeted areas, locked offices, and closets were encountered and it is possible for additional unseen quantities of asbestos -containing floor tile and mastic to be discovered during abatement/demolition activities. Non -friable materials such as floor tile and stair tread may still become friable and release airborne asbestos fibers during the removal process depending on the method of removal required. Strongly adhered floor tiles and/or multiple layers can limit removal techniques to friable methods such as manually chipping and breaking either by machine or by hand. Asbestos -containing black tar pipe elbow mastic was observed on 8" fiberglass pipe insulation above the suspended ceiling grid system. These non -friable black tar pipe elbows were observed on various floors during the asbestos survey. At the time of this survey, both friable and non -friable ACM were observed in good condition, and they do not pose a threat to occupants of the building in their current state. However, prior to demolition activities, friable and non -friable materials must be abated by professionals qualified in asbestos abatement (for more detailed information see Section 6.0 - Regulatory Overview below). Mid -Atlantic recommends third party air monitoring and an asbestos abatement project design due to the size and friable abatement conditions required. The asbestos NESHAP regulates asbestos fiber emissions (prohibits the release of asbestos fibers to the atmosphere during renovation or demolition activities) and asbestos waste disposal practices. NESHAP requires the identification and classification of existing building materials prior to demolition or renovation activity. The EPA recommends that all Regulated ACM (RACM) be removed by a certified asbestos contractor prior to any renovation or demolition activities that may impact the material. In the absence of planned renovation/demolition activities, the EPA recommends that ACM be managed in place whenever asbestos is identified in a building. Any damaged ACM should be removed, repaired, encapsulated, or enclosed. ACM that is not damaged may be managed in place in accordance with a written Operations and Maintenance Program. In North Carolina, asbestos activities are regulated by the North Carolina Health Hazards Control Unit (NC HHCU). The NC HHCU requires that any asbestos -related activity conducted in a public building be performed by personnel licensed by the State of North Carolina. According to the guidelines, RACM must be removed prior to conducting any renovation or demolition activities which will disturb those materials. The owner or operator must provide the NC HHCU with written notification of planned removal activities at least ten working days prior to the commencement of asbestos abatement activities. Removal of RACM must be conducted by a State of North Carolina licensed asbestos abatement contractor. In addition, third party air monitoring must be performed during/ following the abatement. The OSHA Asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The OSHA standard requires that employee exposure to airborne asbestos fibers is maintained below 0.1 asbestos fibers per cubic centimeter of air (0.1 f/ 10 Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 7 cc). The OSHA standard classifies construction and maintenance activities which could disturb ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work. States which administer their own Federally approved OSHA programs may require additional precautions. Fxl>•_1 94►vi140IN&*14UT/to] *K91-1]1III :7x0101LhIiyi140117_11Eel 0611 Mid -Atlantic requested asbestos abatement and demolition cost estimates from four established environmental abatement & demolition companies for the removal and disposal of the ACM identified at the Subject Property. Cost estimates for the abatement ranged from $95,000 - $156,500. Due to limitations encountered during the asbestos survey such as heavily carpeted areas, locked offices, and closets, Mid -Atlantic recommends a contingency range of 30%. Estimated abatement completion time frames ranged between a minimum of 20 working days to a maximum of 40 working days. If a quicker abatement schedule is needed, this may also increase the overall price of abatement. Cost estimates for the demolition ranged from $300,000 - $500,000, and demolition completion time frames ranged from a minimum of 30 working days to a maximum of 60 working days. Mid -Atlantic recommends a formal bidding process allowing contractors to physically visualize the site once the building is vacant and prior to abatement/demolition activities. This will allow contractors to identify any site specific needs and provide a more accurate and competitive bid price for both abatement and demolition activities. Austin Lawrence Partners may also consider bidding abatement and demolition services separately in order to maximize cost savings. 1311 1I►yilkIf_A1I:0P►69 Limiting conditions including heavily carpeted areas, occupied spaces, and locked offices/closets were encountered during the asbestos survey. Quantities are approximated. The potential exists for additional suspect ACM to be exposed during demolition and/or renovation activities. Such materials should be sampled and analyzed for asbestos content prior to any renovation and/or demolition activities that could impact these materials. This NESHAP asbestos survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, and recommendations expressed in this report are based on conditions observed during our survey. The information contained in this report is relevant to the date on which this survey was performed and should not be relied upon to represent conditions at a later date. This report has been prepared on behalf of and exclusively for use by Austin Lawrence Partners for specific application to their project. This report is not a bidding document. IS Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 8 Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or any remediation deemed necessary. Mid -Atlantic does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, expressed or implied, is made. IS Mid Atlantic DRAWINGS I* Mid Atlantic k-q" Legend SUBJECT PROPERTY PARCEL BOUNDARY ROADS i, t { E r Es f ko 1p ;► REFERENCES: SCALE: 1:600 1. 2017 AERIAL IMAGERY FROM NC ONEMAP 2. COUNTY INFORMATION FROM DURHAM COUNTY GIS 0 25 50 100 3. MID -ATLANTIC FIELD NOTES Feet id Atlantic SITE MAP FORMER SOUTH BANK DRAWN BY: i " DATE: JUNE 2021 DRAFT CHECK: JOB NO: R3710.00 Task 07500 Engineering & Environmemal SolutioDs 400 WEST MAIN STREET DURHAM, NORTH CAROLINA ENG. CHECK: GIS NO: 05G-R3710.075-01 APPROVAL: GDI I DWG NO: 1 0 O 0 0 N ooj= N O ro CL o N E-jW Z 0 — 0 0 0 0 z � z LLJ Q m o o Q U 0 -D U 0 ❑ ❑ Y U Y U ELECTRICAL UA U W U _ 0 JANITOR CLOSET CLOSET c, 0 C9 U Z w , z � �r wr zr Cr om om wm Qm UP 2-1 UP ❑ 1UU ❑ 6-1 W J Q CL Y W J 04 Ld (n J Q D_f 0_ W m F Q U Q > U Z J = J_ Z D Z Q Q O Z O W Q W � ❑ ❑ OO(nW WO i Q � 3: Q (n O m 0 O 0 = ~ 0 Z U) F-I Ld m o 0 MECHANICAL V) Q 0 ROOM H U w ❑ ❑ U Vo Q 0 r_ lV c O �■ E o Y L> Z Lou� Q w a E on Y U Q LEGEND N p 1-1 ASBESTOS -CONTAINING SAMPLE LOCATION LLi U w of 0 1 6' w LL APPROX. SCALE: 1 "= 16' w 0 r 0 r 0 g c� z s m Z U r U W J W W J H D U U 0 Z ¢a m2b X N 0 rna �Q J_ w l < as ¢z 00 ujP_ Qa 0 U O V1 za 3� �a o� U) z �z m0 U 60 w Om Y Q vi zQ }a� W 0 zo U r =z oa Ur oLL w �o wr �r a 3Q 0 r 00 z w} w 0 l7 Q N � zo o� ~zz o �a U) W ,,z m W m z w D Of w rm oD z cn O O O O N o I C o w M Z O O O I O O z � z O0 U c� Y U Y U __ Ld _ JANITOR ❑ ELECTRICAL ❑ � > U� 0 U C) o 8 CLOSET CLOSET FORMER BANK Z w O DRIVE-THRU Z E Z a.. of>_ a.. Ofr �.. zr �.. dr 7-1 om om um Qm 34-1,34-2 ON IN UP W 1-2 •UP m Q DN g �Z 20-1•0-2 6-2 2-2 I Y W — (n z Ld D_ cQ�ma U= WOMEN MEN I Z O Z JZ_ J _ c1l DO A Q Z O O m co zNzQ OQc �� U Of (n U of W W p Ld a a T: ElO O O w ,I-D cn a o TELLER WINDOWS U W r ' o ❑ ❑ ❑ ❑ �v_ Q v° co � O Z E o Y C) > Z Lu Q 0 �c >_ W w Y U � Q w = N w U LEGEND z ., 1-2 ASBESTOS -CONTAINING SAMPLE LOCATION f• 0 16' Lv LL_ W APPROX. SCALE: 1 "= 16' 0 O . 0 N 0 0 r- o w m 0 z 0 0 I�, 0 0 0 0 z zzvr-- z Li m O0 p U 0 0 Y U 1' U 1,'\LY :tw _ U U Z z w Z p 33-1, 33-2 �} om Qf} om z} wm wr Qm 32-2 rl wl w � � Z_ Q Y w J (n z Ld O N m OQO cn< � U OJ z � z w = w Q O p 0 a_ z z co O ODUDmcnz Q 0 Iw w p O Lij � Li 0 Q Q O 0 O 0_ w � (n m p CD (n Q p (n I— U w I— Vo U of ._� �� Q a 0 0 Y 0 4i z w Q w a as Y U Q w = N w U LEGEND z w 4-2 ASBESTOS —CONTAINING SAMPLE LOCATION 0 1 s' w Iw w APPROX. SCALE: 1 "= 16' w JANITOR CLOSET ELECTRICAL 0 CLOSET ROOM E 7-2 DN UP 1-3 UP 2-3 WOMEN MEN � � OPEN TO BELOW 0 Z 0 O 0 O N o I 0D w of `n Z O o z O D I O O O Z � Z Ld C) U C� Y U Y U Ld JANITOR 0 CLOSET ELECTRICAL z z w w z 0 0 CLOSET Q Q 0 w a • ar �� m z� wm ar Qm 24-1 DN Till t 1-4 UP ill"i w a_ < _j 2-4 Q Y w z cV (n QOf O � � m~ WOMEN MEN Z Q Q U z O Z J = w � O 0 O O O O� w w w a Q � oo= o cn L� o o- w 'tD m o CD Q o U) U wl H V C O N_ L.1f • ' 0 - Q O iv O 4..) o C) y Z uj Q c w a Y U � Q LU _ N w U LEGEND z w 2-4 ASBESTOS -CONTAINING SAMPLE LOCATION is Of 0 16' Ld w APPROX. SCALE: 1 "= 16' Of O O O O N �_ I O N O W O c9 z O O I� O I o O o z Z#z z 0) U c� Y U Y U U U 0 JANITOR > Z w > CLOSET ELECTRICAL Z 0 CLOSET wr wr Zr 5- 24-: 0 m om wm Qm DIN UP Irl W UP J DN H Z Q Y W J N QUO Q O m U WOMEN MEN Z Z W = Z _jon J DO ZO�O�O DO Q O z 4•3 U D W W O LLJ (nO W of�Q Q = OW O p N Of W .14- D C7 m o Q cn U W Vo U W •� Q o � 0 [� m O Z E o Y � Z wU Q W Q a, Z Y U eo Q w = N L LJ LEGEND z W 44-2 ASBESTOS -CONTAINING SAMPLE LOCATION 00� 0 16' Li-i W W APPROX. SCALE: 1 "= 16' 0 0 0 0 N o I � o w � 0 z 0 0 � � I O O O Z z Lv U Y Uuj Y U JANIT �) U g UOR CLOSET ELECTRICAL CD V' w V' 0 CLOSET z z_ w > .. wr Q .. Wr c9 .. zr OfQ a - a om om wm Qm IN NH W :-6 J a_ H Z Q Y w J N WOMEN MEN Q O' C) C O< Q m� Q U Z � � (� 0 = 0 z w z = F--0 0�of a_ Z F= N O Q Z OO U L n w w Ld �OJL`��� Op� (D = r) (n LL- 0 0' LLI .14- m o cD U Q � U w V o U rY �d co v O Z �E o Y L n � Z w Q w w Y •� U on Q w = N w U LEGEND Z 8 w 2-6 ASBESTOS —CONTAINING SAMPLE LOCATION 0 16' w LL w APPROX. SCALE: 1 "= 16' tY o o O O N � I N CD r- LU 00 O r� O I 0 0 0 z zuz z Ld U c� Y U Y U LLJ = _E Ld 2 Zs U U Of 0 JANITOR Z Z Ld w Z O CLOSET ELECTRICAL Q .. Q ., c� ., Q .. CLOSET om W } om Z } wm d } ¢m FN UPDIN a_Z Y W Q J U7 O N 2-7 Q O WQ m Q d7 WOMEN MEN Q z 0 0 Q of O (if LL UO XO'U/) W WLd p O N cn Of� Q Q 0 OW O p 0_ W D V) m 0 U Q p in H U WI H V 0 o LL Q a O Z o p �> Z w Q c W c Y U El El El w = N w LEGEND U z 2-7 ASBESTOS -CONTAINING SAMPLE LOCATION Q:' 0 16 LLd W APPROX. SCALE: 1"= 16' m O O O O N O I N w Q:� O Z O O I� � O � I O O O zLLJ z O U O Y U Y U LQzz. Ld _ = W U CD ELECTRICAL L Z 0 JANITOR CLOSET CLOSET 0 < Z 0- 0 om wm Qm DIN LLJ DN a_ Q z w J N < �Q�O I� O m O m Q rn WOMEN MEN Z_ Q O U J = J = L`oll D Q co jo zZ 0�O�m ~ O EL Q O z � UU W�(nz 0 O > w w JLLJ Q w o Q o Uo = o 0 w �D U) m o CD Q o U w V o U � r o L y F- 0 O E o Y � � Z w Q c° LLJ a Y F-I El U � Q w = LEGEND N L:Li U z 2-8 ASBESTOS -CONTAINING SAMPLE LOCATION 0 16' Lwi w APPROX. SCALE: 1 "= 16' Q:� APPENDIX A - ASBESTOS SURVEY FORMS AND ANALYTICAL RESULTS IS Mid Atlantic ASBESTOS SURVEY FORM AND ANALYTICAL RESULTS Inspector name: Gareth Hoffmann License Number: INC) 13054 Survey Date: 5/17/2021 - 5/19/2021 Page 1 of _7 Project Name: Former South Bank ACM Survey Project Number: OOOR3710.00 Location: 400 West Main Street, Durham, NC Sample Number Homogeneous Material Sample Location Condition Quantity" Total Friability Results Quantity 12"x12"Pink/Brown Streaked Floor Tile Floor Tile: 5% Chrysotile; 1-1 and Black Mastic Basement Main Stairwell Good 176 ft' Non -Friable Black Mastic: 5% Chrysotile 12"x12" Pink/Brown Streaked Floor Tile i Floor Tile: 5% Chrysotile; 1-2 and Black Mastic First Floor Main Stairwell Good 90ft —806 ft2 Non -Friable Black Mastic: 5% Chrysotile 12"x12"Pink/Brown Streaked Floor Tile Floor Tile: 5% Chrysotile; 1-3 and Black Mastic Second Floor Main Stairwell Good 90 ft' Non -Friable Black Mastic: 5% Chrysotile 12"x12" Pink/Brown Streaked Floor Tile Floor Tile: 5% Chrysotile; 1-4 and Black Mastic Third Floor Main Stairwell Good 90 ft' Non -Friable Black Mastic: 5% Chrysotile 2-1 Popcorn Wall Texture Basement Main Stairwell - SE Good 1,122 ft2 _ 12,000 ft2 Friable 3%Chrysotile 2-2 Popcorn Wall Texture First Floor Main Stairwell - SE Good 690 ft' Friable 3%Chrysotile 2-3 Popcorn Wall Texture Second Floor Main Stairwell - SE Good 690 ft' Friable 3%Chrysotile 2-4 Popcorn Wall Texture Third Floor Main Stairwell - SE Good 690 ft' Friable 3%Chrysotile 2-5 Popcorn Wall Texture Fourth Floor Main Stairwell - SE Good 690 ft' Friable 3%Chrysotile 2-6 Popcorn Wall Texture Fifth Floor Main Stairwell - SE Good 690 ft' Friable 3%Chrysotile 2-7 Popcorn Wall Texture Sixth Floor Main Stairwell - SE Good 690 ft2 Friable 3%Chrysotile 2-8 Popcorn Wall Texture Seventh Floor Main Stairwell - SE Good 690 ft2 Friable 3%Chrysotile 2-9 Popcorn Wall Texture First Floor Main Stairwell - NW Good 690 ft2 Friable is3%Chrysotile 4" Dark Brown Covebase and Tan/Brown Covebase: None Detected; 3-1 Basement Foyer Between Stairs and Parking Deck Good Non -Friable Tan Adhesive: None Detected; Adhesive 210 ft ^' 210 ft Brown Adhesive: None Detected 4" Dark Brown Covebase and Tan/Brown Covebase: None Detected; 3-2 Adhesive Basement Foyer Between Stairs and Parking Deck Good Non -Friable Tan Adhesive: None Detected; Brown Adhesive: None Detected 4 1 12"x12" Light Grey Floor Tile and Black Basement Foyer Between Stairs and Parking Deck Good 656 ft� Non -Friable Floor Tile: 3%Chrysotile; Mastic — 936 ft2 Black Mastic: 5% Chrysotile 12"x12" Light Grey Floor Tile and Black Floor Tile: 3%Chrysotile; 4 2 Mastic Second Floor Server Room - Suite 203 Good 280 ft' Non -Friable Black Mastic: 5% Chrysotile 5-1 2' x 2' Large and Small Pinhole Ceiling Tile Basement Foyer Between Stairs and Parking Deck Good 656 ft' 23,000 ft Friable None Detected 5-2 2' x 2' Large and Small Pinhole Ceiling Tile First Floor Hallway - North Good 1,000 ft' Friable None Detected 5-3 2' x 2' Large and Small Pinhole Ceiling Tile Second Floor Hallway Near East Short Stairwell Good 1,000 ft' Friable None Detected 5-4 2' x 2' Large and Small Pinhole Ceiling Tile Fourth Floor Hallway in Front of Elevator Good 5,900 ft' Friable None Detected 5-5 2' x 2' Large and Small Pinhole Ceiling Tile Fifth Floor Hallway in Front of Elevator Good 7,000 ft' Friable None Detected 5-6 2' x 2' Large and Small Pinhole Ceiling Tile Sixth Floor Hallway in Front of Elevator Good 7,000 ft' Friable None Detected 6-1 Brown Stair Tread and Brown Adhesive Basement Main Stairwell Good 36 Stairs Non -Friable Stair Tread: 2% Chrysotile; 408 Steps Brown Adhesive: None Detected Stair Tread: 2% Chrysotile; 6-2 Brown Stair Tread and Brown Adhesive First Floor Main Stairwell Good 24 Stairs ' (— 2,000 ft) Non -Friable Brown Adhesive: None Detected Stair Tread: 2% Chrysotile; 6-3 Brown Stair Tread and Brown Adhesive Second Floor Main Stairwell Good 24 Stairs Non -Friable Brown Adhesive: None Detected 12"x12"Grey w/ Black and White Streak Floor Tile: 2%Chrysotile; 71 Floor Tile and Black Mastic First Floor Hallway Storage Room Near Stairs Good 49ft2 "' 343 ft' Non -Friable Black Mastic: 5% Chrysotile 7 2 12"x12" Grey w/ Black and White Streak Second Floor Hallway Storage Room Near Stairs Good 49ft2 Non -Friable Floor Tile: 2% Chrysotile; Floor Tile and Black Mastic Black Mastic: 5% Chrysotile 12"x12" Grey w/ Black and White Streak Floor Tile: 2% Chrysotile; 7 3 Floor Tile and Black Mastic Third Floor Hallway Storage Room Near Stairs Good 49ft2 Non -Friable Black Mastic: 5% Chrysotile NOTES: ASBESTOS SURVEY FORM AND ANALYTICAL RESULTS Inspector name: Gareth Hoffmann License Number: (NC) 13054 Survey Date: 5/17/2021 - 5/19/2021 Page 2 of 7 Project Name: Former South Bank ACM Survey Project Number: OOOR3710.00 Location: 400 West Main Street, Durham, NC Sample Number Homogeneous Material Sample Location Condition Quantity * Total Friability Results Quantity 8-1 Brown Fireproofing Basement Parking Garage - North Good >13,500 ft2 ->13,500 ft2 Friable None Detected 8-2 Brown Fireproofing Basement Parking Garage - Northeast Good Friable None Detected 8-3 Brown Fireproofing Basement Parking Garage - East Good Friable None Detected 8-4 Brown Fireproofing Basement Parking Garage - Southeast Good Friable None Detected 8-5 Brown Fireproofing Basement Parking Garage - South Good Friable None Detected 8-6 Brown Fireproofing Basement Parking Garage - Southwest Good Friable None Detected 8-7 Brown Fireproofing Basement Parking Garage - West Good Friable None Detected 8-8 Brown Fireproofing Basement Parking Garage - Northwest Good Friable None Detected 8-9 Brown Fireproofing Basement Parking Garage - Northwest on Ground Good Friable None Detected 9-1 10" Pipe Wrap (Orange Pipe) Over Foam Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected Synthetic Insulation 200 ft "400 ft 9 2 10" Pipe Wrap (Orange Pipe) Over Foam Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected Synthetic Insulation 9-3 10" Pipe Wrap (Orange Pipe) Over Foam Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected Synthetic Insulation 10-1 10" Pipe Elbow Mud (Orange Pipe) Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; 47 w 90 Grey Mud: None Detected 10-2 10" Pipe Elbow Mud (Orange Pipe) Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; Elbows/Tees Elbows/Tees Grey Mud: None Detected 10-3 10" Pipe Elbow Mud (Orange Pipe) Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; Grey Mud: None Detected 11-1 12" Pipe Wrap (Blue Pipe) Over Foam Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected Synthetic Insulation 250 ft -500 ft 11-2 12" Pipe Wrap (Blue Pipe) Over Foam Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected Synthetic Insulation 11-3 12" Pipe Wrap (Blue Pipe) Over Foam Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected Synthetic Insulation 12-1 12" Pipe Elbow (Blue Pipe) Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; 37 "' 60 Grey Mud: None Detected 12-2 12" Pipe Elbow (Blue Pipe) Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; Elbows/Tees Elbows/Tees Grey Mud: None Detected 12-3 12" Pipe Elbow (Blue Pipe) Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; Grey Mud: None Detected 13-1 1.5" Pipe Wrap Over Fiberglass Basement Mechanical/Boiler/Chiller Good 170 ft ^ 170 ft Non -Friable None Detected 13-2 1.5" Pipe Wrap Over Fiberglass Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected 13-3 1.5" Pipe Wrap Over Fiberglass Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected 14-1 1.5" Pipe Elbow Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; 25 - 25 Grey Mud: None Detected 14-2 1.5" Pipe Elbow Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; Elbows/Tees Elbows/Tees Grey Mud: None Detected 14-3 1.5" Pipe Elbow Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; Grey Mud: None Detected 15-1 3" Pipe Wrap Over Fiberglass Basement Mechanical/Boiler/Chiller Good 120 ft ^' 120 ft Non -Friable None Detected 15-2 3" Pipe Wrap Over Fiberglass Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected 15-3 3" Pipe Wrap Over Fiberglass Basement Mechanical/Boiler/Chiller Good Non -Friable None Detected 16-1 3" Pipe Elbow Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; 9 Elbows/Tees - 9 Grey Mud: None Detected 16-2 3" Pipe Elbow Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; Elbows/Tees Grey Mud: None Detected 16-3 3" Pipe Elbow Basement Mechanical/Boiler/Chiller Good Friable Pipe Elbow Wrap: None Detected; Grey Mud: None Detected NOTES: ASBESTOS SURVEY FORM AND ANALYTICAL RESULTS Inspector name: Gareth Hoffmann License Number: (NC) 13054 Survey Date: 5/17/2021 - 5/19/2021 Page 3 of 7 Project Name: Former South Bank ACM Survey Project Number: OOOR3710.00 Location: 400 West Main Street, Durham, NC Sample Number Homogeneous Material Sample Location Condition Quantity * Total Friability Results Quantity White/Skim Coat: None Detected; 17-1 Plaster over CMU First Floor Hallway - North Good 5,200 ft' Friable Grey/Rough Coat: None Detected White/Skim Coat: None Detected; 17-2 Plaster over CMU Second Floor Closet Near East Short Stairwell Good 5,200 ft' Friable Grey/Rough Coat: None Detected 17-3 Plaster over CMU First Floor Hallway of Suite 103 Good (5,200 ft') Friable White/Skim Coat: None Detected; Grey/Rough Coat: None Detected 17-4 Plaster over CMU Second Floor Hallway of Suite 206 Good (5,200 ft') Friable White/Skim Coat: None Detected; "'> 36,000 ft2 Grey/Rough Coat: None Detected 17-5 Plaster over CMU Third Floor Hallway of Suite 301 Good 3,600 ft' Friable White/Skim Coat: None Detected; Grey/Rough Coat: None Detected White/Skim Coat: None Detected; 17-6 Plaster over CMU Fourth Floor Hallway of Suite 401 Good 3,600 ft' Friable Grey/Rough Coat: None Detected White/Skim Coat: None Detected; 17-7 Plaster over CMU Fifth Floor Hallway of Suite 500 Good 3,600 ft' Friable Grey/Rough Coat: None Detected White/Skim Coat: None Detected; 17-8 Plaster over CMU Sixth Floor Hallway in Front of Elevators Good 3,600 ft' Friable Grey/Rough Coat: None Detected White/Skim Coat: None Detected; 17-9 Plaster over CMU Seventh Floor Hallway in Front of Elevators Good 3,600 ft' Friable Grey/Rough Coat: None Detected Covebase: None Detected; 18-1 6" Brown Covebase and Yellow Adhesive First Floor Hallway - North Good 100 ft " 100 ft Non -Friable Yellow Adhesive: None Detected Covebase: None Detected; 18-2 6" Brown Covebase and Yellow Adhesive First Floor Hallway- South Good Non -Friable Yellow Adhesive: None Detected 4" Brown Covebase and Yellow/Brown Covebase: None Detected; 19-1 Adhesive Fourth Floor Main Stairwell Good Non -Friable Yellow Adhesive: None Detected; Brown Adhesive: None Detected 4" Brown Covebase and Yellow/Brown Covebase: None Detected; 19-2 Fifth Floor Main Stairwell Good 1,000 ft -1,000ft Non -Friable Yellow Adhesive: None Detected; Adhesive Brown Adhesive: None Detected 4" Brown Covebase and Yellow/Brown Covebase: None Detected; 19-3 Adhesive Sixth Floor Main Stairwell Good Non -Friable Yellow Adhesive: None Detected; Brown Adhesive: None Detected Carpet and Tan Glue Over 12" x 12" Tan Glue: None Detected; 20-1 Orange and Brown Trowel -Patterned Floor First Floor 103 Storage Room Good Non -Friable Floor Tile: 3%Chrysotile; Tile and Black Mastic 324 ft' '"> 324 ft� Black Mastic: 5%Chrysotile Carpet and Tan Glue Over 12" x 12" Tan Glue: None Detected; 20-2 Orange and Brown Trowel -Patterned Floor First Floor 103 Storage Room Good Non -Friable Floor Tile: 3%Chrysotile; Tile and Black Mastic Black Mastic: 5%Chrysotile Covebase: None Detected; 21-1 4" Black Covebase and Tan Adhesive First Floor ALP Offices Good 375 ft 375 it Non -Friable Tan Adhesive: None Detected 21-2 4" Black Covebase and Tan Adhesive Second Floor Northwest Corner Hallway of Suite 203 Good Non -Friable Covebase: None Detected; Tan Adhesive: None Detected 21-3 4" Black Covebase and Tan Adhesive Fourth Floor Suite 406 Breakroom/Kitchen Good Non -Friable Covebase: None Detected; Tan Adhesive: None Detected 22-1 6" Black Covebase and Tan Adhesive First Floor ALP Offices Good Non -Friable Covebase: None Detected; 100 ft " 100 ft Tan Adhesive: None Detected 22-2 6" Black Covebase and Tan Adhesive First Floor ALP Offices Good Non -Friable Covebase: None Detected; Tan Adhesive: None Detected 23-1 Black Window Caulk First Floor ALP Offices Good 800 Window Panes ("'7,500 ft) Non -Friable None Detected 23-2 Black Window Caulk Second Floor Hallway Near East Short Stairwell Good Non -Friable None Detected 23-3 Black Window Caulk Fourth Floor Hallway in Front of Elevator Good Non -Friable one Detected NOTES: ASBESTOS SURVEY FORM AND ANALYTICAL RESULTS Inspector name: Gareth Hoffmann License Number: (NC) 13054 Survey Date: 5/17/2021 - 5/19/2021 Page 4 of 7 Project Name: Former South Bank ACM Survey Project Number: OOOR3710.00 Location: 400 West Main Street, Durham, NC Sample Number Homogeneous Material Sample Location Condition Quantity * Total Friability Results Quantity 12"x12" Tan w/ White Streaked Floor Tile Floor Tile: 3%Chrysotile; 24 1 and Black Mastic Third Floor Hallway Janitorial Closet Good 35 ft' "245 ft' Non -Friable Black Mastic: 5%Chrysotile 24 2 12"x12" Tan w/ White Streaked Floor Tile Fourth Floor Hallway Janitorial Closet Good 35 ft' Non -Friable Floor Tile: 3%Chrysotile; and Black Mastic Black Mastic: 5%Chrysotile 12"x12" Tan w/ White Streaked Floor Tile Floor Tile: 3%Chrysotile; 24 3 and Black Mastic Fifth Floor Hallway Janitorial Closet Good 35 ft' Non -Friable Black Mastic: 5%Chrysotile 25-1 2' x 2' Pinhole and Deep Fissure Ceiling First Floor Suite 101 Good 709 ft' Friable None Detected Tile 2' x 2' Pinhole and Deep Fissure Ceiling 25 2 Tile Third Floor Hallway in Front of 301 Good >3,000 ft'25-3 "> 3,710 ftz Friable None Detected 2' x 2' Pinhole and Deep Fissure Ceiling Tile Third Floor Hallway in Front of 300-F Good Friable None Detected 4" Cream Covebase and Tan/Brown Covebase: None Detected; 26-1 Adhesive First Floor Suite 101 Good 142 ft " 417 ft Non -Friable Tan Adhesive: None Detected; Brown Adhesive: None Detected 4" Cream Covebase and Tan/Brown Covebase: None Detected; 26 2 Fourth Floor Suite 410-412 Good 275 ft Non -Friable Tan Adhesive: None Detected; Adhesive Brown Adhesive: None Detected Carpet With Brown Adhesive Over Non- Brown Adhesive: None Detected; 27 1 Leveling Compound First Floor Suite 101 Good TBD Unable to Quantify Friable/Friable Grey Leveling Compound: None Detected Carpet With Brown Adhesive Over Non- Brown Adhesive: None Detected; 27-2 Leveling Compound First Floor Suite 301 Good Friable/Friable Grey Leveling Compound: None Detected 28-1 2' x 2' Textured Pinhole Ceiling Tile Second Floor ALP Suite, Main Room Ceiling Good ft 624 ' 624 ftz Friable None Detected 28-2 2' x 2' Textured Pinhole Ceiling Tile Second Floor ALP Suite, Main Room Ceiling Good Friable None Detected 29-1 Textured Trapezoidal Ceiling Tile/Panel Second Floor ALP Suite, Main Room Ceiling Good Friable None Detected 1000 ft, 1000 ft, 29-2 Textured Trapezoidal Ceiling Tile/Panel Second Floor ALP Suite, Main Room Ceiling Good Friable None Detected 30-1 1' x I'Pinhole Ceiling Tile First Floor ALP Offices Good 578 ft' 858 ft Friable None Detected 30-2 1' x I'Pinhole Ceiling Tile Second Floor Server Room -Suite 203 Good 280 ft2 Friable None Detected Sheet Flooring: None Detected; 31-1 Wood Patterned Sheet Flooring Over First Floor ALP Offices Bathroom Good Non -Friable Grey Mastic: None Detected; Ceramic 30 ft' 30 ft' Ceramic Tile: None Detected Wood Patterned Sheet Flooring Over Sheet Flooring: None Detected; 31-2 First Floor ALP Offices Bathroom Good Non -Friable Grey Mastic: None Detected; Ceramic Ceramic Tile: None Detected 12" x 12" Off-white w/ Pink Streaked Floor Floor Tile: 3%Chrysotile; 32-1 Tile and Black Mastic Second Floor Closet Near Southeast Short Stairwell Good 28 ft' —109 ft2 Non -Friable Black Mastic: 5%Chrysotile 12" x 12" Off-white w/ Pink Streaked Floor Floor Tile: 3%Chrysotile; 32 2 Tile and Black Mastic Second Floor Room E Good 81 ft' Non -Friable Black Mastic: 5%Chrysotile 33-1 8" Pipe Elbow (Fiberglass) with Black Second Floor Above Ceiling Tile in Room E Good *TBD *TBD Non -Friable Mastic/Tar Coating: 10%Chrysotile; Mastic/Tar Coating (Estimate 10 Elbows) (Estimate 10 Elbows) Pipe Elbow/Fiberglass: None Detected 33-2 8" Pipe Elbow (Fiberglass) with Black Second Floor Above Ceiling Tile in Room E Good Non -Friable Mastic/Tar Coating: 30%Chrysotile; Mastic/Tar Coating Pipe Elbow/Fiberglass: None Detected Carpet and Yellow Glue Over 12" x 12" Tan Yellow Glue: None Detected; 34-1 Floor Tile and Black Mastic First Floor Suite 103 Good Non -Friable Tan Floor Tile: None Detected; 120 ft' "> 120 ft' Black Mastic: 5% Chrysotile Carpet and Yellow Glue Over 12" x 12" Tan Yellow Glue: None Detected; 34 2 Floor Tile and Black Mastic First Floor Suite 103 Good Non -Friable Tan Floor Tile: None Detected; Black Mastic: 5% Chrysotile 35-1 Wallboard First Floor Suite 103 Good 230 ft' '"> 6,500 ft2 Friable None Detected 35-2 Wallboard Second Floor Office Entrance Suite 203 Good 200 ft' Friable None Detected 35-3 Wallboard Third Floor Hallway Closet Near 301 Good >3,000 ft' Friable None Detected NOTES: ASBESTOS SURVEY FORM AND ANALYTICAL RESULTS Inspector name: Gareth Hoffmann License Number: (NC) 13054 Survey Date: 5/17/2021 - 5/19/2021 Page 5 of 7 Project Name: Former South Bank ACM Survey Project Number: OOOR3710.00 Location: 400 West Main Street, Durham, NC Sample Number Homogeneous Material Sample Location Condition Quantity * Total Friability Results Quantity '" > 6,500 ft2 35-4 Wallboard Fourth Floor Suite 404 Good >3,000 ft' Friable None Detected (Continued) Covebase: None Detected; 36-1 4" Light Tan Covebase and Tan Adhesive Second Floor Hallway of Suite 205 Good 310 ft Non -Friable '" 610 ft Tan Adhesive: None Detected Covebase: None Detected; 36-2 4" Light Tan Covebase and Tan Adhesive Fourth Floor Hallway of Suite 415 Good 300 ft Non -Friable Tan Adhesive: None Detected Covebase: None Detected; 37-1 4" Grey Covebase and Tan Adhesive Fifth Floor Hallway in Front of Suite 500 Good 202 ft " 202 ft Non -Friable Tan Adhesive: None Detected Covebase: None Detected; 37-2 4" Grey Covebase and Tan Adhesive Fifth Floor Hallway in Front of Janitor Closet Good Non -Friable Tan Adhesive: None Detected; Brown Adhesive: None Detected 38-1 2' x 2' Pinhole and Fissure Ceiling Tile Second Floor Office Entrance Suite 203 Good 6,600 ft' - 6,600 ft2 Friable None Detected 38-2 2' x 2' Pinhole and Fissure Ceiling Tile Second Floor Northwest Corner Office Suite 203 Good Friable None Detected 38-3 2' x 2' Pinhole and Fissure Ceiling Tile Second Floor Breakroom Suite 203 Good Friable None Detected Cream Carpet Glue: None Detected; 39-1 Carpet and Cream Carpet Glue Second Floor Conference Room Suite 203 Good Non -Friable Carpet Padding: None Detected; 380 ft' ^' 380 ft' Cream Glue: None Detected Cream Carpet Glue: None Detected; 39-2 Carpet and Cream Carpet Glue Second Floor Conference Room Suite 203 Good Non -Friable Carpet Padding: None Detected; Cream Glue: None Detected 12"x12" White w/ Dark Tan and Black Floor Tile: None Detected; 40 1 Specked Floor Tile and Brown Mastic Second Floor Breakroom Suite 203 Good 80 ft _ 80 ft2 Non -Friable Brown Mastic: None Detected 12"x12" White w/ Dark Tan and Black Floor Tile: None Detected; 40 2 Specked Floor Tile and Brown Mastic Second Floor Breakroom Suite 203 Good Non -Friable Brown Mastic: None Detected 12" x 12" White Floor Tile and Black Floor Tile: None Detected; 41-1 Mastic Sixth Floor Suite 609 Breakroom/Kitchen Good 167 ft' ' 167 ft2 Non -Friable Black Mastic: None Detected 12" x 12" White Floor Tile and Black Floor Tile: None Detected; 41-2 Mastic Sixth Floor Suite 609 Breakroom/Kitchen Good Non -Friable Black Mastic: None Detected 12" x 12" Brown/Tan/Light Brown Floor Tile: None Detected; 42 1 Blotched Floor Tile and Tan Mastic Third Floor Hallway Room -SE Corner Good 120 ft' > 590 ft2 Non -Friable Yellow Mastic: None Detected 42 2 12" x 12" Brown/Tan/Light Brown Third Floor Southeast Room Good 370 ft' Non -Friable Floor Tile: None Detected; Blotched Floor Tile and Tan Mastic Yellow Mastic: None Detected 12" x 12" Brown/Tan/Light Brown i Floor Tile: None Detected; 42 3 Blotched Floor Tile and Tan Mastic Fourth Floor Suite 409 Breakroom/Kitchen d 100 ft Non -Friable Yellow/Black Mastic: 3%Chrysotile 2' x 2' Bumpy Large Pinhole and Large 43-1 Fissure Ceiling Tile Third Floor Hallway Room -SW Corner Good 170 ft' "' 1,000 ft2 Friable None Detected 43 2 2' x 2' Bumpy Large Pinhole and Large Third Floor Suite 300-C Good 352 ft' Friable None Detected Fissure Ceiling Tile 2' x 2' Bumpy Large Pinhole and Large 43-3 Fissure Ceiling Tile Third Floor Suite 300-E Good 390 ft' Friable None Detected Carpet and Yellow Mastic over 12" x 12" Floor Tile: 3%Chrysotile; 44 1 White Floor Tile and Black Mastic Fourth Floor Suite 404 Good 288 ft' 588 ft2 Non -Friable Black Mastic: 5%Chrysotile Yellow Mastic: None Detected; Carpet and Yellow Mastic over 12" x 12" 44 2 White Floor Tile and Black Mastic Fourth Floor Suite 401 Good 300 ft2 Non -Friable Floor Tile: 3%Chrysotile; Black Mastic: 5%Chrysotile Covebase: None Detected; 45-1 4" White Covebase and Tan Adhesive Fourth Floor Suite 403 Good 60 ft 60 ft Non -Friable Tan Adhesive: None Detected Covebase: None Detected; 45-2 4" White Covebase and Tan Adhesive Fourth Floor Suite 403 Good Non -Friable Tan Adhesive: None Detected; Brown Adhesive: None Detected Wallboard: None Detected; 46-1 Wallboard and Joint Compound Fourth Floor Suite 406 Breakroom/Kitchen Good *10,000 ft' '">30,000 ft2 Friable Joint Compound: None Detected Wallboard: None Detected; 46-2 Wallboard and Joint Compound Fourth Floor Suite 410 Good Friable Joint Compound: None Detected NOTES: ASBESTOS SURVEY FORM AND ANALYTICAL RESULTS Inspector name: Gareth Hoffmann License Number: (NC) 13054 Survey Date: 5/17/2021 - 5/19/2021 Page 6 of 7 Project Name: Former South Bank ACM Survey Project Number: OOOR3710.00 Location: 400 West Main Street, Durham, NC Sample Number Homogeneous Material Sample Location Condition Quantity * Total Friability Results Quantity Wallboard: None Detected; 46-3 Wallboard and Joint Compound Fifth Floor Hallway in Front of Suite 500 Good *30,000 ft,Joint Friable Compound: None Detected Wallboard: None Detected; 46-4 Wallboard and Joint Compound Fifth Floor Suite 505 Good Friable 30,000 ft' Joint Compound: None Detected Wallboard: None Detected; 46-5 Wallboard and Joint Compound Sixth Floor Suite 614 Good (Continued) Friable Joint Compound: None Detected Wallboard: None Detected; 46-6 Wallboard and Joint Compound Sixth Floor Suite 602 Good *10,000 ft, Friable Joint Compound: None Detected Wallboard: None Detected; 46-7 Wallboard and Joint Compound Sixth Floor Suite 609 Good Friable Joint Compound: None Detected Covebase: None Detected; 47-1 4" Blue Covebase and Tan Adhesive Seventh Floor Hallway in Front of Mechanical Closet Good Non -Friable 300 ft - 300 ft Tan Adhesive: None Detected CovebaseNone Detected; 47-2 4" Blue Covebase and Tan Adhesive Seventh Floor Hallway in Front of 711 Good Non -Friable Adhi Tan Adhesive: None Detected 2' x 2' Pinhole and Small Fissure Ceiling 48 1 Tile Fourth Floor Suite 406-409 Good 1,375 ft' ' 1,375 k� Friable None Detected 2' x 2' Pinhole and Small Fissure Ceiling 48 2 Tile Fourth Floor Suite 406-409 Good Friable None Detected EXT-1-1 Black Window Caulk Second Floor Roof -North Good 800 Window Panes (-7,500 ft) 800 Window Panes (-7,500 ft) Non -Friable None Detected EXT-1-2 Black Window Caulk Second Floor Roof -West Good Non -Friable None Detected EXT-1-3 Black Window Caulk Second Floor Roof -South Good Non -Friable None Detected EXT-2-1 Black Flashing/Seam Caulk Second Floor Roof -North Good 600 ft -600 ft Non -Friable None Detected EXT-2-2 Black Flashing/Seam Caulk Second Floor Roof -West Good Non -Friable None Detected EXT-2-3 Black Flashing/Seam Caulk Second Floor Roof -South Good Non -Friable None Detected EXT-3-1 Light Grey Expansion Caulk Second Floor Roof -North Good 2,000 ft ^'2,000ft Non -Friable None Detected EXT-3-2 Light Grey Expansion Caulk Second Floor Roof -West Good Non -Friable None Detected EXT-3-3 Light Grey Expansion Caulk Second Floor Roof -South Good Non -Friable None Detected Caulk: None Detected; EXT-4-1 Silver Caulk on Metal Wrap Seventh Floor Pipes to South Cooling Tower on Roof Good Non -Friable 20ft -20 ft Metal Wrap: None Detected Caulk: None Detected; EXT-4-2 Silver Caulk on Metal Wrap Seventh Floor Pipes to South Cooling Tower on Roof Good Non -Friable Metal Wrap: None Detected Roof Membrane: None Detected; White Insulation: None Detected; R-1-1 Roof Membrane Second Floor Roof -North Good Non -Friable Yellow Foam: None Detected; 14,000 ft' " 14,000 f? Black Tar: None Detected Roof Membrane: None Detected; White Insulation: None Detected; R-1-2 Roof Membrane Second Floor Roof -West Good Non -Friable Yellow Foam: None Detected; Paper: None Detected; Black Tar: None Detected Roof Flashing: None Detected; White Insulation: None Detected; R-2-1 Roof Flashing Second Floor Roof -North Good Non -Friable Yellow Foam: None Detected; Paper: None Detected; 720 ft " 720 ft Black Tar: None Detected Roof Flashing: None Detected; White Insulation: None Detected; R-2-2 Roof Flashing Second Floor Roof -West Good Non -Friable Yellow Foam: None Detected; Paper: None Detected; Black Tar: None Detected NOTES: ASBESTOS SURVEY FORM AND ANALYTICAL RESULTS Inspector name: Gareth Hoffmann License Number: (NC) 13054 Survey Date: 5/17/2021 - 5/19/2021 Page 7 of 7 Project Name: Former South Bank ACM Survey Project Number: OOOR3710.00 Location: 400 West Main Street, Durham, NC Sample Number Homogeneous Material Sample Location Condition Quantity * Total Friability Results Quantity Roof Membrane: None Detected; White Insulation: None Detected; R-3-1 Roof Membrane Seventh Floor Roof -East Good Non -Friable Yellow Foam: None Detected; Paper: None Detected; 7,000 ft' —7,000 ft' Black Tar: None Detected Roof Membrane: None Detected; Yellow Foam: None Detected; R-3-2 Roof Membrane Seventh Floor Roof -North Good Non -Friable Paper: None Detected; Black Tar: None Detected Roof Flashing: None Detected; White Insulation: None Detected; R-4-1 Roof Flashing Seventh Floor Roof -East Good Non -Friable Yellow Foam: None Detected; Paper: None Detected; 400 ft "400 ft Black Tar: None Detected Roof Flashing: None Detected; White Insulation: None Detected; R-4-2 Roof Flashing Seventh Floor Roof -North Good Non -Friable Yellow Foam: None Detected; Paper: None Detected; Black Tar: None Detected Roof Flashing: None Detected; White Insulation: None Detected; R-5-1 Roof Membrane Penthouse Roof -Center Good 3,000 ft' ^'3,000 ft' Non -Friable Yellow Foam: None Detected; Paper: None Detected; Black Tar: None Detected Condition: Based on a percentage of the building material remaining intact at time of survey. Friability: Classification of building material's ability to become broken, crushed, or pulvarized with hand pressure at time of survey. * Quantities are estimated. NOTES: Floor Tiles and Black Mastic found under carnet may exist in other areas of the building not included in auantification estimates. Wallboard and Pipe elbow mastic/tar was observed in other floors of the building but was unable to sample due to occupancy limitations. No Flashing on Penthouse Roof. was APPENDIX B - LABORATORY ANALYTICAL DATA I* Mid Atlantic 0 eurofins May 25, 2021 Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 CLIENT PROJECT: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 CEI LAB CODE: A216842v3 Dear Customer: Enclosed are asbestos analysis results for PLM Bulk samples received at our laboratory on May 20, 2021. The samples were analyzed for asbestos using polarizing light microscopy (PLM) per the EPA 600 Method. Sample results containing >1 % asbestos are considered asbestos -containing materials (ACMs) per EPA regulatory requirements. The detection limit for the EPA 600 Method is <1 % asbestos by weight as determined by visual estimation. Thank you for your business and we look forward to continuing good relations. rA V i Q TESTING NVLAF LAB CODE 101768-0 Kind Regards, Tianbao Bai, Ph.D., CIH Laboratory Director 730 SE Maynard Road • Cary, NC 27511 • 919.481.1413 tiff eurnfins AMENDED CEI ASBESTOS ANALYTICAL REPORT By: Polarized Light Microscopy Prepared for Mid -Atlantic Associates, Inc. CLIENT PROJECT: 400 W. Main St. ACM Survey, OOOR3710.00 -Task 07500 LAB CODE: A216842v3 TEST METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 REPORT DATE. 05/24/21 TOTAL SAMPLES ANALYZED: 168 # SAMPLES >1 % ASBESTOS: 53 tiff eurofins AEI AMENDED PROJECT: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 1020 LAB CODE: A2168420 ASBESTOS Client ID Layer Lab ID Color Sample Description % 1-1 A96959A Pink,Brown Floor Tile A96959B Black Mastic 1-2 A96960A Pink,Brown Floor Tile A96960B Black Mastic 1-3 A96961A Pink,Brown Floor Tile A96961 B Black Mastic 1-4 A96962A Pink,Brown Floor Tile A96962B Black Mastic 2-1 A96963 White Popcorn Wall Texture 2-2 A96964 White Popcorn Wall Texture 2-3 A96965 White Popcorn Wall Texture 2-4 A96966 White Popcorn Wall Texture 2-5 A96967 White Popcorn Wall Texture 2-6 A96968 White Popcorn Wall Texture 2-7 A96969 White Popcorn Wall Texture 2-8 A96970 White Popcorn Wall Texture 2-9 A96971 White Popcorn Wall Texture 3-1 A96972A Dark Brown Covebase None Detected --------------------------------------------------------------- Layer 1 Layer 2 A96972B A96972B Tan Brown Adhesive Adhesive None Detected None Detected 3-2 A96973A Dark Brown Covebase None Detected --------------------------------------------------------------- Layer 1 Layer 2 A96973B A96973B Tan Brown Adhesive Adhesive None Detected None Detected 4-1 A96974A Light Gray Floor Tile A96974B Black Mastic 4-2 A96975A Light Gray Floor Tile A96975B Black Mastic 5-1 A96976 White Large And Small Pinhole Ceiling Tile None Detected 5-2 A96977 White Large And Small Pinhole Ceiling Tile None Detected Page 1 of 11 ti AMENDED Asbestos Report Summary tiff �u f Uf i n 5 AEI By: POLARIZING LIGHT MICROSCOPY PROJECT: 400 W. Main St. ACM Survey, LAB CODE: A2168420 000R3710.00 - Task 07500 METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 1020 ASBESTOS Client ID Layer Lab ID Color Sample Description % 5-3 A96978 White Large And Small Pinhole Ceiling Tile None Detected 5-4 A96979 White Large And Small Pinhole Ceiling Tile None Detected 5-5 A96980 White Large And Small Pinhole Ceiling Tile None Detected 5-6 A96981 White Large And Small Pinhole Ceiling Tile None Detected 6-1 A96982A Brown Stair Tread A96982B Brown Adhesive None Detected 6-2 A96983A Brown Stair Tread A96983B Brown Adhesive None Detected 6-3 A96984A Brown Stair Tread A96984B Brown Adhesive None Detected 7-1 A96985A Gray,Black Floor Tile White A96985B Black Mastic 7-2 A96986A Gray,Black Floor Tile White A96986B Black Mastic 7-3 A96987A Gray,Black Floor Tile White A96987B Black Mastic 8-1 A96988 Brown Fireproofing None Detected 8-2 A96989 Brown Fireproofing None Detected 8-3 A96990 Brown Fireproofing None Detected 8-4 A96991 Brown Fireproofing None Detected 8-5 A96992 Brown Fireproofing None Detected 8-6 A96993 Brown Fireproofing None Detected 8-7 A96994 Brown Fireproofing None Detected 8-8 A96995 Brown Fireproofing None Detected 8-9 A96996 Brown Fireproofing None Detected 9-1 A96997 Orange Pipe Wrap None Detected Page 2 of 11 .ti AMENDED Asbestos Report Summary tiff eu rnf i n s AEI By: POLARIZING LIGHT MICROSCOPY PROJECT: 400 W. Main St. ACM Survey, LAB CODE: A2168420 000R3710.00 - Task 07500 METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 ASBESTOS Client ID Layer Lab ID Color Sample Description % 9-2 A96998 Orange Pipe Wrap None Detected 9-3 A96999 Orange Pipe Wrap None Detected 10-1 Layer 1 Layer 2 A97000 A97000 Orange Gray Pipe Elbow Pipe Elbow None Detected None Detected 10-2 --------------------------------------------------------------- Layer 1 Layer 2 A97001 A97001 Orange Gray Pipe Elbow Pipe Elbow None Detected None Detected 10-3 --------------------------------------------------------------- Layer 1 Layer 2 A97002 A97002 Orange Gray Pipe Elbow Pipe Elbow None Detected None Detected 11-1 A97003 Blue Pipe Wrap None Detected 11-2 A97004 Blue Pipe Wrap None Detected 11-3 A97005 Blue Pipe Wrap None Detected 12-1 --------------------------------------------------------------- Layer 1 Layer 2 A97006 A97006 Blue Gray Pipe Elbow Pipe Elbow None Detected None Detected 12-2 --------------------------------------------------------------- Layer 1 Layer 2 A97007 A97007 Blue Gray Pipe Elbow Pipe Elbow None Detected None Detected 12-3 --------------------------------------------------------------- Layer 1 Layer 2 A97008 A97008 Blue Gray Pipe Elbow Pipe Elbow None Detected None Detected 13-1 A97009 White Pipe Wrap None Detected 13-2 A97010 White Pipe Wrap None Detected 13-3 A97011 White Pipe Wrap None Detected 14-1 --------------------------------------------------------------- Layer 1 Layer 2 A97012 A97012 White Gray Pipe Elbow Pipe Elbow None Detected None Detected 14-2 --------------------------------------------------------------- Layer 1 Layer 2 A97013 A97013 White Gray Pipe Elbow Pipe Elbow None Detected None Detected 14-3 --------------------------------------------------------------- Layer 1 Layer 2 A97014 A97014 White Gray Pipe Elbow Pipe Elbow None Detected None Detected 15-1 A97015 White Pipe Wrap None Detected 15-2 A97016 White Pipe Wrap None Detected 15-3 A97017 White Pipe Wrap None Detected 16-1 --------------------------------------------------------------- Layer 1 Layer 2 A97018 A97018 White Gray Pipe Elbow Pipe Elbow None Detected None Detected Page 3 of 11 tiff eurnfins AEI AMENDED PROJECT: 400 W. Main St. ACM Survey, 000R3710.00 - Task 07500 Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 LAB CODE: A2168420 ASBESTOS Client ID Layer Lab ID Color Sample Description % 16-2 Layer 1 A97019 White Pipe Elbow None Detected --------------------------------------------------------------- Layer 2 A97019 Gray Pipe Elbow None Detected 16-3 Layer 1 A97020 White Pipe Elbow None Detected --------------------------------------------------------------- Layer 2 A97020 Gray Pipe Elbow None Detected 17-1 Layer 1 A97021 White Plaster Skim Coat None Detected --------------------------------------------------------------- Layer 2 A97021 Gray Plaster Rough Coat Over Cmu None Detected 17-2 Layer 1 A97022 White Plaster Skim Coat None Detected --------------------------------------------------------------- Layer 2 A97022 Gray Plaster Rough Coat Over Cmu None Detected 17-3 Layer 1 A97023 White Plaster Skim Coat None Detected --------------------------------------------------------------- Layer 2 A97023 Gray Plaster Rough Coat Over Cmu None Detected 17-4 Layer 1 A97024 White Plaster Skim Coat None Detected --------------------------------------------------------------- Layer 2 A97024 Gray Plaster Rough Coat Over Cmu None Detected 17-5 Layer 1 A97025 White Plaster Skim Coat None Detected Layer 2 A97025 Gray Plaster Rough Coat Over Cmu None Detected 17-6 Layer 1 A97026 White Plaster Skim Coat None Detected --------------------------------------------------------------- Layer 2 A97026 Gray Plaster Rough Coat Over Cmu None Detected 17-7 Layer 1 A97027 White Plaster Skim Coat None Detected --------------------------------------------------------------- Layer 2 A97027 Gray Plaster Rough Coat Over Cmu None Detected 17-8 Layer 1 A97028 White Plaster Skim Coat None Detected --------------------------------------------------------------- Layer 2 A97028 Gray Plaster Rough Coat Over Cmu None Detected 17-9 Layer 1 A97029 White Plaster Skim Coat None Detected --------------------------------------------------------------- Layer 2 A97029 Gray Plaster Rough Coat Over Cmu None Detected 18-1 A97030A Brown Covebase None Detected A97030B Yellow Adhesive None Detected 18-2 A97031A Brown Covebase None Detected Layer 1 A97031 B Yellow Adhesive None Detected --------------------------------------------------------------- Layer 2 A97031 B Brown Adhesive None Detected 19-1 A97032A Brown Covebase None Detected Layer 1 A97032B Yellow Adhesive None Detected --------------------------------------------------------------- Layer 2 A97032B Brown Adhesive None Detected 19-2 A97033A Brown Covebase None Detected Page 4 of 11 tiff eurofins AEI AMENDED PROJECT: 400 W. Main St. ACM Survey, 000R3710.00 - Task 07500 Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 1020 LAB CODE: A2168420 ASBESTOS Client ID Layer Lab ID Color Sample Description % Layer 1 Layer 2 A97033B A97033B Yellow Brown Adhesive Adhesive None Detected None Detected 19-3 A97034A Brown Covebase None Detected Layer 1 Layer 2 A97034B A97034B Yellow Brown Adhesive Adhesive None Detected None Detected 20-1 --------------------------------------------------------------- Layer 1 Layer 2 A97035A A97035A Tan Orange,Brown Glue Floor Tile None Detected EMEMM A97035B Black Mastic 20-2 Layer 1 Layer 2 A97036A A97036A Tan Orange,Brown Glue Floor Tile None Detected EMEMM A97036B Black Mastic 21-1 A97037A Black Covebase None Detected A97037B Tan Adhesive None Detected 21-2 A97038A Black Covebase None Detected A97038B Tan Adhesive None Detected 21-3 A97039A Black Covebase None Detected A97039B Tan Adhesive None Detected 22-1 A97040A Black Covebase None Detected A97040B Tan Adhesive None Detected 22-2 A97041A Black Covebase None Detected A97041 B Tan Adhesive None Detected 23-1 A97042 Black Window Caulk None Detected 23-2 A97043 Black Window Caulk None Detected 23-3 A97044 Black Window Caulk None Detected 24-1 A97045A Tan,White Floor Tile A97045B Black Mastic 24-2 A97046A Tan,White Floor Tile A97046B Black Mastic 24-3 A97047A Tan,White Floor Tile A97047B Black Mastic Page 5 of 11 ti AMENDED Asbestos Report Summary tiff �u f Uf i n 5 AEI By: POLARIZING LIGHT MICROSCOPY PROJECT: 400 W. Main St. ACM Survey, LAB CODE: A2168420 000R3710.00 - Task 07500 METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 1020 ASBESTOS Client ID Layer Lab ID Color Sample Description % 25-1 A97048 White Pinhole And Deep Fissure Ceiling Tile None Detected 25-2 A97049 White Pinhole And Deep Fissure Ceiling Tile None Detected 25-3 A97050 White Pinhole And Deep Fissure Ceiling Tile None Detected 26-1 A97051A Cream Covebase None Detected --------------------------------------------------------------- Layer 1 Layer 2 A97051 B A97051 B Tan Brown Adhesive Adhesive None Detected None Detected 26-2 A97052A Cream Covebase None Detected Layer 1 Layer 2 A97052B A97052B Tan Brown Adhesive Adhesive None Detected None Detected 27-1 --------------------------------------------------------------- Layer 1 Layer 2 A97053 A97053 Brown Gray Adhesive Leveling Compound None Detected None Detected 27-2 --------------------------------------------------------------- Layer 1 Layer 2 A97054 A97054 Brown Gray Adhesive Leveling Compound None Detected None Detected 28-1 A97055 White Textured Pinhole Ceiling Tile None Detected 28-2 A97056 White Textured Pinhole Ceiling Tile None Detected 29-1 A97057 White Textured Trapezoidal Ceiling Tile/panel None Detected 29-2 A97058 White Textured Trapezoidal Ceiling Tile/panel None Detected 30-1 A97059 White Pinhole Ceiling Tile None Detected 30-2 A97060 White Pinhole Ceiling Tile None Detected 31-1 A97061A Wood, Patterned Sheet Flooring None Detected A97061 B Gray Mastic None Detected A97061C Tan,White Ceramic Tile None Detected 31-2 A97062A Wood, Patterned Sheet Flooring None Detected A97062B Gray Mastic None Detected A97062C Tan,White Ceramic Tile None Detected 32-1 A97063A Off-white,Pink Floor Tile Page 6 of 11 tiff eurofins AEI AMENDED PROJECT: 400 W. Main St. ACM Survey, 000R3710.00 - Task 07500 Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 1020 LAB CODE: A2168420 ASBESTOS Client ID Layer Lab ID Color Sample Description % A97063B Black Mastic 32-2 A97064A Off-white,Pink Floor Tile A97064B Black Mastic 33-1 Layer 1 A97065 Black Mastic/tar Coating--------------------------------------------------------------- Layer 2 A97065 Yellow Pipe Elbow None Detected 33-2 Layer 1 A97066 Black Mastic/tar Coating--------------------------------------------------------------- Layer 2 A97066 Yellow Pipe Elbow None Detected 34-1 --------------------------------------------------------------- Layer 1 Layer 2 A97067A A97067A Yellow Tan Glue Floor Tile None Detected None Detected A97067B Black Mastic 34-2 --------------------------------------------------------------- Layer 1 Layer 2 A97068A A97068A Yellow Tan Glue Floor Tile None Detected None Detected A97068B Black Mastic 35-1 A97069 White Wallboard/Mud None Detected 35-2 A97070 White Wallboard/Mud None Detected 35-3 A97071 White Wallboard None Detected 35-4 A97072 White Wallboard None Detected 36-1 A97073A Light Tan Covebase None Detected A97073B Tan Adhesive None Detected 36-2 A97074A Light Tan Covebase None Detected A97074B Tan Adhesive None Detected 37-1 A97075A Gray Covebase None Detected A97075B Tan Adhesive None Detected 37-2 A97076A Gray Covebase None Detected --------------------------------------------------------------- Layer 1 Layer 2 A97076B A97076B Tan Brown Adhesive Adhesive None Detected None Detected 38-1 A97077 White Pinhole And Fissure Ceiling Tile None Detected 38-2 A97078 White Pinhole And Fissure Ceiling Tile None Detected 38-3 A97079 White Pinhole And Fissure Ceiling Tile None Detected 39-1 --------------------------------------------------------------- Layer 1 Layer 2 A97080A A97080A Cream Black Carpet Glue Carpet None Detected None Detected Page 7 of 11 ti AMENDED Asbestos Report Summary tiff �u f Uf i n 5 AEI By: POLARIZING LIGHT MICROSCOPY PROJECT: 400 W. Main St. ACM Survey, LAB CODE: A2168420 00OR3710.00 - Task 07500 METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 1020 ASBESTOS Client ID Layer Lab ID Color Sample Description % A97080B Cream Carpet Glue None Detected 39-2 Layer 1 Layer 2 A97081A A97081A Cream Black Carpet Glue Carpet None Detected None Detected A97081 B Cream Carpet Glue None Detected 40-1 A97082A White,Dark Tan Floor Tile None Detected A97082B Brown Mastic None Detected 40-2 A97083A White,Dark Tan Floor Tile None Detected A97083B Brown Mastic None Detected 41-1 A97084A White Floor Tile None Detected A97084B Black Mastic None Detected 41-2 A97085A White Floor Tile None Detected A97085B Black Mastic None Detected 42-1 A97086A Brown,Tan Floor Tile None Detected A97086B Yellow Mastic None Detected 42-2 A97087A Brown,Tan Floor Tile None Detected A97087B Yellow Mastic None Detected 42-3 A97088A Brown,Tan Floor Tile None Detected A97088B Yellow,Black Mastic 43-1 A97089 White Bumpy Large Pinhole And Large None Detected Fissure Ceiling Tile 43-2 A97090 White Bumpy Large Pinhole And Large None Detected Fissure Ceiling Tile 43-3 A97091 White Bumpy Large Pinhole And Large None Detected Fissure Ceiling Tile 44-1 A97092A White Floor Tile A97092B Black Mastic 44-2 --------------------------------------------------------------- Layer 1 Layer 2 A97093A A97093A Yellow White Mastic Floor Tile None Detected EMMEM A97093B Black Mastic • 45-1 A97094A White Covebase None Detected A97094B Tan Adhesive None Detected 45-2 A97095A White Covebase None Detected Page 8 of 11 ti AMENDED Asbestos Report Summary tiff �u f Uf i n 5 AEI By: POLARIZING LIGHT MICROSCOPY PROJECT: 400 W. Main St. ACM Survey, LAB CODE: A2168420 00OR3710.00 - Task 07500 METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 1020 ASBESTOS Client ID Layer Lab ID Color Sample Description % Layer 1 Layer 2 A97095B A97095B Tan Brown Adhesive Adhesive None Detected None Detected 46-1 Layer 1 Layer 2 A97096 A97096 White White Joint Compound Wallboard None Detected None Detected 46-2 Layer 1 Layer 2 A97097 A97097 White White Joint Compound Wallboard None Detected None Detected 46-3 Layer 1 Layer 2 A97098 A97098 White White Joint Compound Wallboard None Detected None Detected 46-4 --------------------------------------------------------------- Layer 1 Layer 2 A97099 A97099 White White Joint Compound Wallboard None Detected None Detected 46-5 --------------------------------------------------------------- Layer 1 Layer 2 A97100 A97100 White White Joint Compound Wallboard None Detected None Detected 46-6 --------------------------------------------------------------- Layer 1 Layer 2 A97101 A97101 White White Joint Compound Wallboard None Detected None Detected 46-7 Layer 1 Layer 2 A97102 A97102 White White Joint Compound Wallboard None Detected None Detected 47-1 A97103A Blue Covebase None Detected A97103B Tan Adhesive None Detected 47-2 A97104A Blue Covebase None Detected A97104B Tan Adhesive None Detected 48-1 A97105 White Pinhole And Small Fissure Ceiling Tile None Detected 48-2 A97106 White Pinhole And Small Fissure Ceiling Tile None Detected EXT-1-1 A97107 Black Window Caulk None Detected EXT-1-2 A97108 Black Window Caulk None Detected EXT-1-3 A97109 Black Window Caulk None Detected EXT-2-1 A97110 Black Flashing/seam Caulk None Detected EXT-2-2 A97111 Black Flashing/seam Caulk None Detected EXT-2-3 A97112 Black Flashing/seam Caulk None Detected EXT-3-1 A97113 Gray Expansion Caulk None Detected EXT-3-2 A97114 Gray Expansion Caulk None Detected Page 9 of 11 tiff eurnfins AEI AMENDED PROJECT: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 LAB CODE: A2168420 ASBESTOS Client ID Layer Lab ID Color Sample Description % EXT-3-3 A97115 Gray Expansion Caulk None Detected EXT-4-1 Layer 1 A97116 Silver Caulk None Detected --------------------------------------------------------------- Layer 2 A97116 Silver Metal Wrap None Detected EXT-4-2 Layer 1 A97117 Silver Caulk None Detected --------------------------------------------------------------- Layer 2 A97117 Silver Metal Wrap None Detected R-1-1 Layer 1 A97118 Black Roof Membrane None Detected --------------------------------------------------------------- Layer 2 A97118 White Insulation None Detected --------------------------------------------------------------- Layer 3 A97118 Yellow Foam None Detected Layer 4 A97118 Black Tar None Detected R-1-2 Layer 1 A97119 Black Roof Membrane None Detected --------------------------------------------------------------- Layer 2 A97119 White Insulation None Detected --------------------------------------------------------------- Layer 3 A97119 Yellow Foam None Detected --------------------------------------------------------------- Layer 4 A97119 Brown Paper None Detected --------------------------------------------------------------- Layer 5 A97119 Black Tar None Detected R-2-1 Layer 1 A97120 Black Roof Flashing None Detected --------------------------------------------------------------- Layer 2 A97120 White Insulation None Detected Layer 3 A97120 Yellow Foam None Detected Layer 4 A97120 Brown Paper None Detected --------------------------------------------------------------- Layer 5 A97120 Black Tar None Detected R-2-2 Layer 1 A97121 Black Roof Flashing None Detected --------------------------------------------------------------- Layer 2 A97121 White Insulation None Detected --------------------------------------------------------------- Layer 3 A97121 Yellow Foam None Detected --------------------------------------------------------------- Layer 4 A97121 Brown Paper None Detected --------------------------------------------------------------- Layer 5 A97121 Black Tar None Detected R-3-1 Layer 1 A97122 Black Roof Membrane None Detected --------------------------------------------------------------- Layer 2 A97122 White Insulation None Detected --------------------------------------------------------------- Layer 3 A97122 Yellow Foam None Detected --------------------------------------------------------------- Layer 4 A97122 Brown Paper None Detected --------------------------------------------------------------- Layer 5 A97122 Black Tar None Detected R-3-2 Layer 1 A97123 Black Roof Membrane None Detected --------------------------------------------------------------- Layer 2 A97123 Yellow Foam None Detected Page 10 of 11 tiff eurnfins AEI AMENDED PROJECT: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 Asbestos Report Summary By: POLARIZING LIGHT MICROSCOPY METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 LAB CODE: A2168420 ASBESTOS Client ID Layer Lab ID Color Sample Description % --------------------------------------------------------------- Layer 3 A97123 Brown Paper None Detected Layer 4 A97123 Black Tar None Detected R-4-1 Layer 1 A97124 Black Roof Flashing None Detected Layer 2 A97124 White Insulation None Detected Layer 3 A97124 Yellow Foam None Detected Layer 4 A97124 Brown Paper None Detected --------------------------------------------------------------- Layer 5 A97124 Black Tar None Detected R-4-2 Layer 1 A97125 Black Roof Flashing None Detected Layer 2 A97125 White Insulation None Detected Layer 3 A97125 Yellow Foam None Detected --------------------------------------------------------------- Layer 4 A97125 Brown Paper None Detected --------------------------------------------------------------- Layer 5 A97125 Black Tar None Detected R-5-1 Layer 1 A97126 Black Roof Membrane None Detected --------------------------------------------------------------- Layer 2 A97126 White Insulation None Detected --------------------------------------------------------------- Layer 3 A97126 Yellow Foam None Detected --------------------------------------------------------------- Layer 4 A97126 Brown Paper None Detected Layer 5 A97126 Black Tar None Detected Page 11 of 11 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, INC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % 1-1 Floor Tile Homogeneous 95% Vinyl A96959A P i n k, B rown Non -fibrous Tightly Bound A96959B Mastic Homogeneous 95% Mastic VMIM FIR Black Non -fibrous Bound 1-2 Floor Tile Homogeneous 95% Vinyl A96960A Pi n k, B rown Non -fibrous Tightly Bound A96960B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 1-3 Floor Tile Homogeneous 95% Vinyl VMIM Fill A96961 A Pi n k, B rown Non -fibrous Tightly Bound A96961 B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 1-4 Floor Tile Homogeneous 95% Vinyl A96962A Pink,Brown Non -fibrous Tightly Bound Page 1 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % A96962B Mastic Homogeneous 95% Mastic • - Black Non -fibrous Bound 2-1 Popcorn Wall Texture Heterogeneous 57% Binder A96963 White 35% Calc Carb Non -fibrous 5% Paint Bound 2-2 Popcorn Wall Texture Heterogeneous 57% Binder A96964 White 35% Calc Carb Non -fibrous 5% Paint Bound 2-3 Popcorn Wall Texture Heterogeneous 57% Binder A96965 White 35% Calc Carb Non -fibrous 5% Paint Bound 2-4 Popcorn Wall Texture Heterogeneous 57% Binder A96966 White 35% Calc Carb Non -fibrous 5% Paint Bound 2-5 Popcorn Wall Texture Heterogeneous 57% Binder A96967 White 35% Calc Carb Non -fibrous 5% Paint Bound 2-6 Popcorn Wall Texture Heterogeneous 57% Binder A96968 White 35% Calc Carb Non -fibrous 5% Paint Bound Page 2 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % 2-7 Popcorn Wall Texture Heterogeneous 57% Binder • - A96969 White 35% Calc Carb Non -fibrous 5% Paint Bound 2-8 Popcorn Wall Texture Heterogeneous 57% Binder A96970 White 35% Calc Carb Non -fibrous 5% Paint Bound 2-9 Popcorn Wall Texture Heterogeneous 57% Binder A96971 White 35% Calc Carb Non -fibrous 5% Paint Bound 3-1 Covebase Homogeneous 100% Vinyl None Detected A96972A Dark Brown Non -fibrous Tightly Bound Layer 1 Adhesive Homogeneous 100% Mastic None Detected A96972B Tan Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A96972B Brown Non -fibrous Bound 3-2 Covebase Homogeneous 100% Vinyl None Detected A96973A Dark Brown Non -fibrous Tightly Bound Page 3 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % Layer 1 Adhesive Homogeneous 100% Mastic None Detected A96973B Tan Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A96973B Brown Non -fibrous Bound 4-1 Floor Tile Homogeneous 97% Vinyl 11 A96974A Light Gray Non -fibrous Tightly Bound A96974B Mastic Homogeneous 95% Mastic 16 Black Non -fibrous Bound 4-2 Floor Tile Homogeneous 97% Vinyl A96975A Light Gray Non -fibrous Tightly Bound A96975B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 5-1 Large And Small A96976 Pinhole Ceiling Tile Heterogeneous White Fibrous Loosely Bound 40% Cellulose 30% Perlite None Detected 25% Fiberglass 5% Binder Page 4 of 46 tiff eurofins CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 5-2 Large And Small Heterogeneous 40% Cellulose 30% Perlite None Detected A96977 Pinhole Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 5-3 Large And Small Heterogeneous 40% Cellulose 30% Perlite None Detected A96978 Pinhole Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 5-4 Large And Small Heterogeneous 40% Cellulose 30% Perlite None Detected A96979 Pinhole Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 5-5 Large And Small Heterogeneous 40% Cellulose 30% Perlite None Detected A96980 Pinhole Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 5-6 Large And Small Heterogeneous 40% Cellulose 30% Perlite None Detected A96981 Pinhole Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 6-1 Stair Tread Homogeneous 98% Vinyl A96982A Brown Non -fibrous Tightly Bound A96982B Adhesive Homogeneous 100% Mastic None Detected Brown Non -fibrous Bound Page 5 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 IClient ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS I Lab ID Description Attributes Fibrous Non -Fibrous % 6-2 Stair Tread Homogeneous 98% Vinyl A96983A Brown Non -fibrous Tightly Bound A96983B Adhesive Homogeneous 100% Mastic None Detected Brown Non -fibrous Bound 6-3 Stair Tread Homogeneous 98% Vinyl A96984A Brown Non -fibrous Tightly Bound A96984B Adhesive Homogeneous 100% Mastic None Detected Brown Non -fibrous Bound 7-1 Floor Tile Homogeneous 98% Vinyl A96985A Gray,Black White Non -fibrous Tightly Bound A96985B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 7-2 Floor Tile Homogeneous 98% Vinyl A96986A Gray,Black White Non -fibrous Tightly Bound Page 6 of 46 tiff eurofins CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % A96986B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 7-3 Floor Tile Homogeneous 98% Vinyl A96987A Gray,Black White Non -fibrous Tightly Bound A96987B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 8-1 Fireproofing Homogeneous 100% Cellulose None Detected A96988 Brown Fibrous Loose 8-2 Fireproofing Homogeneous 100% Cellulose None Detected A96989 Brown Fibrous Loose 8-3 Fireproofing Homogeneous 100% Cellulose None Detected A96990 Brown Fibrous Loose 8-4 Fireproofing Homogeneous 100% Cellulose None Detected A96991 Brown Fibrous Loose Page 7 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 8-5 Fireproofing Homogeneous 100% Cellulose None Detected A96992 Brown Fibrous Loose 8-6 Fireproofing Homogeneous 100% Cellulose None Detected A96993 Brown Fibrous Loose 8-7 Fireproofing Homogeneous 100% Cellulose None Detected A96994 Brown Fibrous Loose 8-8 Fireproofing Homogeneous 100% Cellulose None Detected A96995 Brown Fibrous Loose 8-9 Fireproofing Homogeneous 100% Cellulose None Detected A96996 Brown Fibrous Loose 9-1 Pipe Wrap Heterogeneous 20% Cellulose 20% Metal Foil None Detected A96997 Orange 38% Fiberglass 20% Mastic Fibrous 2% Paint Bound 9-2 Pipe Wrap Heterogeneous 20% Cellulose 20% Metal Foil None Detected A96998 Orange 38% Fiberglass 20% Mastic Fibrous 2% Paint Bound Page 8 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % 9-3 Pipe Wrap Heterogeneous 20% Cellulose 20% Metal Foil None Detected A96999 Orange 38% Fiberglass 20% Mastic Fibrous 2% Paint Bound 10-1 Pipe Elbow Heterogeneous 40% Cellulose 2% Paint None Detected Layer 1 Orange 58% Fiberglass A97000 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97000 Gray Fibrous Loose 10-2 Pipe Elbow Heterogeneous 40% Cellulose 2% Paint None Detected Layer 1 Orange 58% Fiberglass A97001 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97001 Gray Fibrous Loose 10-3 Pipe Elbow Heterogeneous 40% Cellulose 2% Paint None Detected Layer 1 Orange 58% Fiberglass A97002 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97002 Gray Fibrous Loose Page 9 of 46 tiff eurofins CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 11-1 Pipe Wrap Heterogeneous 20% Cellulose 20% Mastic None Detected A97003 Blue 20% Fiberglass 38% Foam Fibrous 2% Paint Bound 11-2 Pipe Wrap Heterogeneous 20% Cellulose 20% Mastic None Detected A97004 Blue 20% Fiberglass 38% Foam Fibrous 2% Paint Bound 11-3 Pipe Wrap Heterogeneous 20% Cellulose 20% Mastic None Detected A97005 Blue 20% Fiberglass 38% Foam Fibrous 2% Paint Bound 12-1 Pipe Elbow Heterogeneous 40% Cellulose 2% Paint None Detected Layer 1 Blue 10% Fiberglass 48% Foam A97006 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97006 Gray Fibrous Loose 12-2 Pipe Elbow Heterogeneous 40% Cellulose 2% Paint None Detected Layer 1 Blue 10% Fiberglass 48% Foam A97007 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97007 Gray Fibrous Loose Page 10 of 46 tiff eurofins CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 12-3 Pipe Elbow Heterogeneous 40% Cellulose 2% Paint None Detected Layer 1 Blue 10% Fiberglass 48% Foam A97008 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97008 Gray Fibrous Loose 13-1 A97009 Pipe Wrap Heterogeneous White Fibrous Bound 20% 38% Cellulose Fiberglass 20% 20% 2% Mastic None Detected Metal Foil Paint 13-2 Pipe Wrap Heterogeneous 20% Cellulose 20% Mastic None Detected A97010 White 38% Fiberglass 20% Metal Foil Fibrous 2% Paint Bound 13-3 Pipe Wrap Heterogeneous 20% Cellulose 20% Mastic None Detected A97011 White 38% Fiberglass 20% Metal Foil Fibrous 2% Paint Bound 14-1 Pipe Elbow Heterogeneous 88% Cellulose 2% Paint None Detected Layer 1 White 10% Fiberglass A97012 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97012 Gray Fibrous Loose Page 11 of 46 tiff eurofins CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 14-2 Pipe Elbow Heterogeneous 88% Cellulose 2% Paint None Detected Layer 1 White 10% Fiberglass A97013 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97013 Gray Fibrous Loose 14-3 Pipe Elbow Heterogeneous 88% Cellulose 2% Paint None Detected Layer 1 White 10% Fiberglass A97014 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97014 Gray Fibrous Loose 15-1 Pipe Wrap Heterogeneous 20% Cellulose 20% Mastic None Detected A97015 White 38% Fiberglass 20% Metal Foil Fibrous 2% Paint Bound 15-2 Pipe Wrap Heterogeneous 20% Cellulose 20% Mastic None Detected A97016 White 38% Fiberglass 20% Metal Foil Fibrous 2% Paint Bound 15-3 Pipe Wrap Heterogeneous 20% Cellulose 20% Mastic None Detected A97017 White 38% Fiberglass 20% Metal Foil Fibrous 2% Paint Bound Page 12 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 ;lient ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS -ab ID Description Attributes Fibrous Non -Fibrous % 16-1 Pipe Elbow Heterogeneous 88% Cellulose 2% Paint None Detected Layer 1 White 10% Fiberglass A97018 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97018 Gray Fibrous Loose 16-2 Pipe Elbow Heterogeneous 88% Cellulose 2% Paint None Detected Layer 1 White 10% Fiberglass A97019 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97019 Gray Fibrous Loose 16-3 Pipe Elbow Heterogeneous 88% Cellulose 2% Paint None Detected Layer 1 White 10% Fiberglass A97020 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Homogeneous 15% Fiberglass 85% Binder None Detected A97020 Gray Fibrous Loose 17-1 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97021 Non -fibrous 2% Paint Bound Page 13 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % Layer 2 Plaster Rough Coat Homogeneous 75% Silicates None Detected A97021 Over Cmu Gray 25% Binder Non -fibrous Bound 17-2 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97022 Non -fibrous 2% Paint Bound ------------------------------------------------------------------ Layer 2 Plaster Rough Coat Homogeneous 75% Silicates None Detected A97022 Over Cmu Gray 25% Binder Non -fibrous Bound 17-3 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97023 Non -fibrous 2% Paint Bound ------------------------------------------------------------------ Layer 2 Plaster Rough Coat Homogeneous 75% Silicates None Detected A97023 Over Cmu Gray 25% Binder Non -fibrous Bound 17-4 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97024 Non -fibrous 2% Paint Bound ------------------------------------------------------------------ Layer 2 Plaster Rough Coat Homogeneous 75% Silicates None Detected A97024 Over Cmu Gray 25% Binder Non -fibrous Bound Page 14 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % 17-5 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97025 Non -fibrous 2% Paint Bound ------------------------------------------------------------------ Layer 2 Plaster Rough Coat Homogeneous 75% Silicates None Detected A97025 Over Cmu Gray 25% Binder Non -fibrous Bound 17-6 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97026 Non -fibrous 2% Paint Bound ------------------------------------------------------------------ Layer 2 Plaster Rough Coat Homogeneous 75% Silicates None Detected A97026 Over Cmu Gray 25% Binder Non -fibrous Bound 17-7 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97027 Non -fibrous 2% Paint Bound ------- Layer 2 ------------- Plaster Rough Coat --------------- Homogeneous --------- 75% --------- Silicates ------------- None Detected A97027 Over Cmu Gray 25% Binder Non -fibrous Bound 17-8 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97028 Non -fibrous 2% Paint Bound Page 15 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous Layer 2 Plaster Rough Coat Homogeneous 75% Silicates None Detected A97028 Over Cmu Gray 25% Binder Non -fibrous Bound 17-9 Plaster Skim Coat Heterogeneous 78% Binder None Detected Layer 1 White 20% Calc Carb A97029 Non -fibrous 2% Paint Bound ------------------------------------------------------------------ Layer 2 Plaster Rough Coat Homogeneous 75% Silicates None Detected A97029 Over Cmu Gray 25% Binder Non -fibrous Bound 18-1 Covebase Homogeneous 100% Vinyl None Detected A97030A Brown Non -fibrous Tightly Bound A97030B Adhesive Homogeneous 100% Mastic None Detected Yellow Non -fibrous Bound 18-2 Covebase Homogeneous 100% Vinyl None Detected A97031A Brown Non -fibrous Tightly Bound Layer 1 Adhesive Homogeneous 100% Mastic None Detected A97031 B Yellow Non -fibrous Bound Page 16 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous Layer 2 Adhesive Homogeneous 100% Mastic None Detected A97031B Brown Non -fibrous Bound 19-1 Covebase Homogeneous 100% Vinyl None Detected A97032A Brown Non -fibrous Tightly Bound Layer 1 Adhesive Homogeneous 100% Mastic None Detected A97032B Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A97032B Brown Non -fibrous Bound 19-2 Covebase Homogeneous 100% Vinyl None Detected A97033A Brown Non -fibrous Tightly Bound Layer 1 Adhesive Homogeneous 100% Mastic None Detected A97033B Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A97033B Brown Non -fibrous Bound Page 17 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 000R3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 ;lient ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS -ab ID Description Attributes Fibrous Non -Fibrous % 19-3 Covebase Homogeneous 100% Vinyl None Detected A97034A Brown Non -fibrous Tightly Bound Layer 1 Adhesive Homogeneous 100% Mastic None Detected A97034B Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A97034B Brown Non -fibrous Bound 20-1 Glue Homogeneous <1 % Synthetic Fiber 100% Mastic None Detected Layerl Tan A97035A Non -fibrous Bound Lab Notes: No carpet present. ------------------------------------------------------------------ Layer 2 Floor Tile Homogeneous 97% Vinyl A97035A Orange, Brown Non -fibrous Tightly Bound A97035B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 20-2 Glue Homogeneous <1 % Synthetic Fiber 100% Mastic None Detected Layerl Tan A97036A Non -fibrous Bound Lab Notes: No carpet present. Page 18 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous Layer 2 Floor Tile Homogeneous 97% Vinyl A97036A Orange, Brown Non -fibrous Tightly Bound A97036B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 21-1 Covebase Homogeneous 100% Vinyl None Detected A97037A Black Non -fibrous Tightly Bound A97037B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 21-2 Covebase Homogeneous 100% Vinyl None Detected A97038A Black Non -fibrous Tightly Bound A97038B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 21-3 Covebase Homogeneous 100% Vinyl None Detected A97039A Black Non -fibrous Tightly Bound Page 19 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous A97039B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 22-1 Covebase Homogeneous 100% Vinyl None Detected A97040A Black Non -fibrous Tightly Bound A97040B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 22-2 Covebase Homogeneous 100% Vinyl None Detected A97041 A Black Non -fibrous Tightly Bound A97041 B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 23-1 Window Caulk Homogeneous 100% Caulk None Detected A97042 Black Non -fibrous Bound 23-2 Window Caulk Homogeneous 100% Caulk None Detected A97043 Black Non -fibrous Bound Page 20 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % 23-3 Window Caulk Homogeneous 100% Caulk None Detected A97044 Black Non -fibrous Bound 24-1 Floor Tile Homogeneous 97% Vinyl A97045A Tan, W h ite Non -fibrous Tightly Bound A97045B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 24-2 Floor Tile Homogeneous 97% Vinyl A97046A Tan, W h ite Non -fibrous Tightly Bound A97046B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 24-3 Floor Tile Homogeneous 97% Vinyl A97047A Tan, W h ite Non -fibrous Tightly Bound A97047B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound Page 21 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 25-1 Pinhole And Deep Heterogeneous 40% Cellulose 30% Perlite None Detected A97048 Fissure Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 25-2 Pinhole And Deep Heterogeneous 40% Cellulose 30% Perlite None Detected A97049 Fissure Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 25-3 Pinhole And Deep Heterogeneous 40% Cellulose 30% Perlite None Detected A97050 Fissure Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 26-1 Covebase Homogeneous 100% Vinyl None Detected A97051A Cream Non -fibrous Tightly Bound Layer 1 Adhesive Homogeneous 100% Mastic None Detected A97051B Tan Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A97051B Brown Non -fibrous Bound 26-2 Covebase Homogeneous 100% Vinyl None Detected A97052A Cream Non -fibrous Tightly Bound Page 22 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous Layer 1 Adhesive Homogeneous 100% Mastic None Detected A97052B Tan Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A97052B Brown Non -fibrous Bound 27-1 Adhesive Homogeneous <1 % Synthetic Fiber 100% Mastic None Detected Layer 1 Brown A97053 Non -fibrous Bound Lab Notes: No carpet present. ------------------------------------------------------------------ Layer 2 Leveling Compound Homogeneous 100% Binder None Detected A97053 Gray Non -fibrous Bound 27-2 Adhesive Homogeneous <1 % Synthetic Fiber 100% Mastic None Detected Layer 1 Brown A97054 Non -fibrous Bound Lab Notes: No carpet present. ------------------------------------------------------------------ Layer 2 Leveling Compound Homogeneous 100% Binder None Detected A97054 Gray Non -fibrous Bound 28-1 Textured Pinhole Heterogeneous 40% Cellulose 30% Perlite None Detected A97055 Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound Page 23 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 28-2 Textured Pinhole Heterogeneous 40% Cellulose 30% Perlite None Detected A97056 Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 29-1 Textured Trapezoidal Heterogeneous 40% Cellulose 30% Perlite None Detected A97057 Ceiling Tile/panel White 25% Fiberglass 5% Binder Fibrous Loosely Bound 29-2 Textured Trapezoidal Heterogeneous 40% Cellulose 30% Perlite None Detected A97058 Ceiling Tile/panel White 25% Fiberglass 5% Binder Fibrous Loosely Bound 30-1 Pinhole Ceiling Tile Heterogeneous 40% Cellulose 30% Perlite None Detected A97059 White 25% Fiberglass 5% Binder Fibrous Loosely Bound 30-2 Pinhole Ceiling Tile Heterogeneous 40% Cellulose 30% Perlite None Detected A97060 White 25% Fiberglass 5% Binder Fibrous Loosely Bound 31-1 Sheet Flooring Homogeneous 100% Vinyl None Detected A97061A Wood,Patterned Non -fibrous Tightly Bound A97061 B Mastic Homogeneous 100% Mastic None Detected Gray Non -fibrous Bound Page 24 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % A97061C Ceramic Tile Homogeneous Tan,White Non -fibrous Tightly Bound 70% 30% Silicates None Detected Binder 31-2 Sheet Flooring Homogeneous 100% Vinyl None Detected A97062A Wood, Patterned Non -fibrous Tightly Bound A97062B Mastic Homogeneous 100% Mastic None Detected Gray Non -fibrous Bound A97062C Ceramic Tile Homogeneous 70% Silicates None Detected Tan,White 30% Binder Non -fibrous Tightly Bound 32-1 Floor Tile Homogeneous 97% Vinyl A97063A Off-white,Pink Non -fibrous Tightly Bound A97063B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 32-2 Floor Tile Homogeneous 97% Vinyl A97064A Off-wh ite, Pi n k Non -fibrous Tightly Bound Page 25 of 46 tiff eu rof i n S CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 IClient ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS I Lab ID Description Attributes Fibrous Non -Fibrous A97064B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 33-1 Mastic/tar Coating Homogeneous 5% Fiberglass 85% Tar Layer 1 Black A97065 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Heterogeneous 40% Cellulose 10% Paint None Detected A97065 Yellow 50% Fiberglass Fibrous Bound 33-2 Mastic/tar Coating Homogeneous 5% Fiberglass 85% Tar Layer 1 Black A97066 Fibrous Bound ------------------------------------------------------------------ Layer 2 Pipe Elbow Heterogeneous 40% Cellulose 10% Paint None Detected A97066 Yellow 50% Fiberglass Fibrous Bound 34-1 Glue Homogeneous <1 % Synthetic Fiber 100% Mastic None Detected Layer 1 Yellow A97067A Non -fibrous Bound Lab Notes: No carpet present. ------------------------------------------------------------------ Layer 2 Floor Tile Homogeneous 100% Vinyl None Detected A97067A Tan Non -fibrous Tightly Bound Page 26 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS IClient Lab ID Description Attributes Fibrous Non -Fibrous % I A97067B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 34-2 Glue Homogeneous <1 % Synthetic Fiber 100% Mastic None Detected Layer 1 Yellow A97068A Non -fibrous Bound Lab Notes: No carpet present. ------------------------------------------------------------------ Layer 2 Floor Tile Homogeneous 100% Vinyl None Detected A97068A Tan Non -fibrous Tightly Bound A97068B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 35-1 Wallboard/Mud Heterogeneous 15% Cellulose 73% Gypsum None Detected A97069 White 10% Calc Carb Fibrous 2% Paint Bound 35-2 Wallboard/Mud Heterogeneous 15% Cellulose 73% Gypsum None Detected A97070 White 10% Calc Carb Fibrous 2% Paint Bound 35-3 Wallboard Heterogeneous 15% Cellulose 83% Gypsum None Detected A97071 White 2% Paint Fibrous Bound Page 27 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 35-4 Wallboard Heterogeneous 15% Cellulose 83% Gypsum None Detected A97072 White 2% Paint Fibrous Bound 36-1 Covebase Homogeneous 100% Vinyl None Detected A97073A Light Tan Non -fibrous Tightly Bound A97073B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 36-2 Covebase Homogeneous 100% Vinyl None Detected A97074A Light Tan Non -fibrous Tightly Bound A97074B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 37-1 Covebase Homogeneous 100% Vinyl None Detected A97075A Gray Non -fibrous Tightly Bound A97075B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound Page 28 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 37-2 Covebase Homogeneous 100% Vinyl None Detected A97076A Gray Non -fibrous Tightly Bound Layer 1 Adhesive Homogeneous 100% Mastic None Detected A97076B Tan Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A97076B Brown Non -fibrous Bound 38-1 Pinhole And Fissure Heterogeneous 40% Cellulose 30% Perlite None Detected A97077 Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 38-2 Pinhole And Fissure Heterogeneous 40% Cellulose 30% Perlite None Detected A97078 Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 38-3 Pinhole And Fissure Heterogeneous 40% Cellulose 30% Perlite None Detected A97079 Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 39-1 Carpet Glue Homogeneous 100% Mastic None Detected Layer 1 Cream A97080A Non -fibrous Bound Page 29 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous Layer 2 Carpet Homogeneous 20% Cellulose 80% Foam None Detected A97080A Black Fibrous Bound A97080B Carpet Glue Homogeneous <1 % Synthetic Fiber 100% Mastic None Detected Cream Non -fibrous Bound 39-2 Carpet Glue Homogeneous 100% Mastic None Detected Layer 1 Cream A97081 A Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Carpet Homogeneous 20% Cellulose 80% Foam None Detected A97081 A Black Fibrous Bound A97081 B Carpet Glue Homogeneous <1 % Synthetic Fiber 100% Mastic None Detected Cream Non -fibrous Bound 40-1 Floor Tile Homogeneous 100% Vinyl None Detected A97082A White,Dark Tan Non -fibrous Tightly Bound A97082B Mastic Homogeneous 100% Mastic None Detected Brown Non -fibrous Bound Page 30 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 40-2 Floor Tile Homogeneous 100% Vinyl None Detected A97083A White,Dark Tan Non -fibrous Tightly Bound A97083B Mastic Homogeneous 100% Mastic None Detected Brown Non -fibrous Bound 41-1 Floor Tile Homogeneous 100% Vinyl None Detected A97084A White Non -fibrous Tightly Bound A97084B Mastic Homogeneous <1 % Cellulose 100% Mastic None Detected Black Non -fibrous Bound 41-2 Floor Tile Homogeneous 100% Vinyl None Detected A97085A White Non -fibrous Tightly Bound A97085B Mastic Homogeneous <1 % Cellulose 100% Mastic None Detected Black Non -fibrous Bound 42-1 Floor Tile Homogeneous 100% Vinyl None Detected A97086A Brown,Tan Non -fibrous Tightly Bound Page 31 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous A97086B Mastic Homogeneous 100% Mastic None Detected Yellow Non -fibrous Bound 42-2 Floor Tile Homogeneous 100% Vinyl None Detected A97087A Brown,Tan Non -fibrous Tightly Bound A97087B Mastic Homogeneous 100% Mastic None Detected Yellow Non -fibrous Bound 42-3 Floor Tile Homogeneous 100% Vinyl None Detected A97088A Brown,Tan Non -fibrous Tightly Bound A97088B Mastic Homogeneous 97% Mastic Yellow,Black Non -fibrous Bound Lab Notes: Unable to separate mastics for analysis. 43-1 Bumpy Large Pinhole Heterogeneous 40% Cellulose 30% Perlite None Detected A97089 And Large Fissure White 25% Fiberglass 5% Binder Ceiling Tile Fibrous Loosely Bound 43-2 Bumpy Large Pinhole Heterogeneous 40% Cellulose 30% Perlite None Detected A97090 And Large Fissure White 25% Fiberglass 5% Binder Ceiling Tile Fibrous Loosely Bound Page 32 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % 43-3 Bumpy Large Pinhole Heterogeneous 40% Cellulose 30% Perlite None Detected A97091 And Large Fissure White 25% Fiberglass 5% Binder Ceiling Tile Fibrous Loosely Bound 44-1 Floor Tile Homogeneous 97% Vinyl A97092A White Non -fibrous Tightly Bound Lab Notes: No carpet present. A97092B Mastic Homogeneous 95% Mastic =17M. tin Black Non -fibrous Bound 44-2 Mastic Homogeneous 100% Mastic None Detected Layer 1 Yellow A97093A Non -fibrous Bound Lab Notes: No carpet present. ------------------------------------------------------------------ Layer 2 Floor Tile Homogeneous 97% Vinyl A97093A White Non -fibrous Tightly Bound A97093B Mastic Homogeneous 95% Mastic Black Non -fibrous Bound 45-1 Covebase A97094A Homogeneous White Non -fibrous Tightly Bound 100% Vinyl None Detected Page 33 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous A97094B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 45-2 Covebase Homogeneous 100% Vinyl None Detected A97095A White Non -fibrous Tightly Bound Layer 1 Adhesive Homogeneous 100% Mastic None Detected A97095B Tan Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Adhesive Homogeneous 100% Mastic None Detected A97095B Brown Non -fibrous Bound 46-1 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A97096 Non -fibrous 5% Paint Bound ------------------------------------------------------------------ Layer 2 Wallboard Heterogeneous 15% Cellulose 85% Gypsum None Detected A97096 White Fibrous Bound 46-2 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A97097 Non -fibrous 5% Paint Bound Page 34 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 ;lient ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS -ab ID Description Attributes Fibrous Non -Fibrous % Layer 2 Wallboard Heterogeneous 15% Cellulose 85% Gypsum None Detected A97097 White Fibrous Bound 46-3 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A97098 Non -fibrous 5% Paint Bound ------------------------------------------------------------------ Layer 2 Wallboard Heterogeneous 15% Cellulose 85% Gypsum None Detected A97098 White Fibrous Bound 46-4 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A97099 Non -fibrous 5% Paint Bound ------------------------------------------------------------------ Layer 2 Wallboard Heterogeneous 15% Cellulose 85% Gypsum None Detected A97099 White Fibrous Bound 46-5 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A97100 Non -fibrous 5% Paint Bound ------- Layer 2 --------------------------------- Wallboard Heterogeneous 15% Cellulose ---- 85% ---------------------- Gypsum None Detected A97100 White Fibrous Bound Page 35 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous 46-6 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A97101 Non -fibrous 5% Paint Bound ------------------------------------------------------------------ Layer 2 Wallboard Heterogeneous 15% Cellulose 85% Gypsum None Detected A97101 White Fibrous Bound 46-7 Joint Compound Heterogeneous 60% Binder None Detected Layer 1 White 35% Calc Carb A97102 Non -fibrous 5% Paint Bound ------------------------------------------------------------------ Layer 2 Wallboard Heterogeneous 15% Cellulose 85% Gypsum None Detected A97102 White Fibrous Bound 47-1 Covebase Homogeneous 100% Vinyl None Detected A97103A Blue Non -fibrous Tightly Bound A97103B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 47-2 Covebase Homogeneous 100% Vinyl None Detected A97104A Blue Non -fibrous Tightly Bound Page 36 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous A97104B Adhesive Homogeneous 100% Mastic None Detected Tan Non -fibrous Bound 48-1 Pinhole And Small Heterogeneous 40% Cellulose 30% Perlite None Detected A97105 Fissure Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound 48-2 Pinhole And Small Heterogeneous 40% Cellulose 30% Perlite None Detected A97106 Fissure Ceiling Tile White 25% Fiberglass 5% Binder Fibrous Loosely Bound EXT-1-1 Window Caulk Homogeneous 100% Caulk None Detected A97107 Black Non -fibrous Bound EXT-1-2 Window Caulk Homogeneous 100% Caulk None Detected A97108 Black Non -fibrous Bound EXT-1-3 Window Caulk Homogeneous 100% Caulk None Detected A97109 Black Non -fibrous Bound EXT-2-1 Flashing/seam Caulk Homogeneous 100% Caulk None Detected A97110 Black Non -fibrous Bound Page 37 of 46 tiff eu rofi n s CEI ASBESTOS BULK ANALYSIS AMENDED By: POLARIZING LIGHT MICROSCOPY Client: Mid -Atlantic Associates, Inc. Lab Code: A216842v3 1125 E. Morehead St. Date Received: 05-20-21 Charlotte, NC 28204 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous EXT-2-2 Flashing/seam Caulk Homogeneous 100% Caulk None Detected A97111 Black Non -fibrous Bound EXT-2-3 Flashing/seam Caulk Homogeneous 100% Caulk None Detected A97112 Black Non -fibrous Bound EXT-3-1 Expansion Caulk Homogeneous 100% Caulk None Detected A97113 Gray Non -fibrous Bound EXT-3-2 Expansion Caulk Homogeneous 100% Caulk None Detected A97114 Gray Non -fibrous Bound EXT-3-3 Expansion Caulk Homogeneous 100% Caulk None Detected A97115 Gray Non -fibrous Bound EXT-4-1 Caulk Homogeneous 100% Caulk None Detected Layer 1 Silver A97116 Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Metal Wrap Homogeneous 100% Metal Foil None Detected A97116 Silver Non -fibrous Bound Page 38 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % EXT-4-2 Caulk Homogeneous 100% Caulk None Detected Layer 1 Silver A97117 Non -fibrous Bound ------------------------------------------------------------------ Layer 2 Metal Wrap Homogeneous 100% Metal Foil None Detected A97117 Silver Non -fibrous Bound R-1-1 Roof Membrane Heterogeneous 30% Fiberglass 70% Tar None Detected Layer 1 Black A97118 Fibrous Bound ------------------------------------------------------------------ Layer 2 Insulation Homogeneous 100% Cellulose None Detected A97118 White Fibrous ------------------------------------------------------------------ Loosely Bound Layer 3 Foam Homogeneous 100% Foam None Detected A97118 Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 4 Tar Homogeneous 100% Tar None Detected A97118 Black Non -fibrous Bound R-1-2 Roof Membrane Heterogeneous 30% Fiberglass Layer 1 Black A97119 Fibrous Bound 70% Tar None Detected Page 39 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 ;lient ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS -ab ID Description Attributes Fibrous Non -Fibrous % Layer 2 Insulation Homogeneous 100% Cellulose None Detected A97119 White Fibrous ------------------------------------------------------------------ Loosely Bound Layer 3 Foam Homogeneous 100% Foam None Detected A97119 Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 4 Paper Homogeneous 100% Cellulose None Detected A97119 Brown Fibrous Bound ------------------------------------------------------------------ Layer 5 Tar Homogeneous 100% Tar None Detected A97119 Black Non -fibrous Bound R-2-1 Roof Flashing Heterogeneous 30% Fiberglass 70% Tar None Detected Layer 1 Black A97120 Fibrous Bound ------------------------------------------------------------------ Layer 2 Insulation Homogeneous 100% Cellulose None Detected A97120 White Fibrous ------------------------------------------------------------------ Loosely Bound Layer 3 Foam Homogeneous 100% Foam None Detected A97120 Yellow Non -fibrous Bound Page 40 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 ;lient ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS -ab ID Description Attributes Fibrous Non -Fibrous % Layer 4 Paper Homogeneous 100% Cellulose None Detected A97120 Brown Fibrous Bound ------------------------------------------------------------------ Layer 5 Tar Homogeneous 100% Tar None Detected A97120 Black Non -fibrous Bound R-2-2 Roof Flashing Heterogeneous 30% Fiberglass 70% Tar None Detected Layer 1 Black A97121 Fibrous Bound ------------------------------------------------------------------ Layer 2 Insulation Homogeneous 100% Cellulose None Detected A97121 White Fibrous ------------------------------------------------------------------ Loosely Bound Layer 3 Foam Homogeneous 100% Foam None Detected A97121 Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 4 Paper Homogeneous 100% Cellulose None Detected A97121 Brown Fibrous Bound ------------------------------------------------------------------ Layer 5 Tar Homogeneous 100% Tar None Detected A97121 Black Non -fibrous Bound Page 41 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % R-3-1 Roof Membrane Heterogeneous 30% Fiberglass 70% Tar None Detected Layer 1 Black A97122 Fibrous Bound ------------------------------------------------------------------ Layer 2 Insulation Homogeneous 100% Cellulose None Detected A97122 White Fibrous ------------------------------------------------------------------ Loosely Bound Layer 3 Foam Homogeneous 100% Foam None Detected A97122 Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 4 Paper Homogeneous 100% Cellulose None Detected A97122 Brown Fibrous Bound ------------------------------------------------------------------ Layer 5 Tar Homogeneous 100% Tar None Detected A97122 Black Non -fibrous Bound R-3-2 Roof Membrane Heterogeneous 30% Fiberglass 70% Tar None Detected Layer 1 Black A97123 Fibrous Bound ------------------------------------------------------------------ Layer 2 Foam Homogeneous 100% Foam None Detected A97123 Yellow Non -fibrous Bound Page 42 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 ;lient ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS -ab ID Description Attributes Fibrous Non -Fibrous % Layer 3 Paper Homogeneous 100% Cellulose None Detected A97123 Brown Fibrous Bound ------------------------------------------------------------------ Layer 4 Tar Homogeneous 100% Tar None Detected A97123 Black Non -fibrous Bound R-4-1 Roof Flashing Heterogeneous 30% Fiberglass 70% Tar None Detected Layer 1 Black A97124 Fibrous Bound ------------------------------------------------------------------ Layer 2 Insulation Homogeneous 100% Cellulose None Detected A97124 White Fibrous ------------------------------------------------------------------ Loosely Bound Layer 3 Foam Homogeneous 100% Foam None Detected A97124 Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 4 Paper Homogeneous 100% Cellulose None Detected A97124 Brown Fibrous Bound ------------------------------------------------------------------ Layer 5 Tar Homogeneous 100% Tar None Detected A97124 Black Non -fibrous Bound Page 43 of 46 tiff eu rofi n 5 CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % R-4-2 Roof Flashing Heterogeneous 30% Fiberglass 70% Tar None Detected Layer 1 Black A97125 Fibrous Bound ------------------------------------------------------------------ Layer 2 Insulation Homogeneous 100% Cellulose None Detected A97125 White Fibrous ------------------------------------------------------------------ Loosely Bound Layer 3 Foam Homogeneous 100% Foam None Detected A97125 Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 4 Paper Homogeneous 100% Cellulose None Detected A97125 Brown Fibrous Bound ------------------------------------------------------------------ Layer 5 Tar Homogeneous 100% Tar None Detected A97125 Black Non -fibrous Bound R-5-1 Roof Membrane Heterogeneous 30% Fiberglass 70% Tar None Detected Layer 1 Black A97126 Fibrous Bound ------------------------------------------------------------------ Layer 2 Insulation Homogeneous 100% Cellulose None Detected A97126 White Fibrous Loosely Bound Page 44 of 46 tiff eu rof i n S CEI AMENDED Client: Mid -Atlantic Associates, Inc. 1125 E. Morehead St. Charlotte, NC 28204 ASBESTOS BULK ANALYSIS By: POLARIZING LIGHT MICROSCOPY Project: 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 ASBESTOS BULK PLM, EPA 600 METHOD Lab Code: A216842v3 Date Received: 05-20-21 Date Analyzed: 05-24-21 Date Reported: 05-24-21 Client ID Lab Lab NON -ASBESTOS COMPONENTS ASBESTOS Lab ID Description Attributes Fibrous Non -Fibrous % Layer 3 Foam Homogeneous 100% Foam None Detected A97126 Yellow Non -fibrous Bound ------------------------------------------------------------------ Layer 4 Paper Homogeneous 100% Cellulose None Detected A97126 Brown Fibrous Bound ------------------------------------------------------------------ Layer 5 Tar Homogeneous 100% Tar None Detected A97126 Black Non -fibrous Bound Page 45 of 46 tiff eurofins LEGEND: Non-Anth = Non-Asbestiform Anthophyllite Non-Trem = Non-Asbestiform Tremolite Calc Carb = Calcium Carbonate METHOD: EPA 600 / R93 / 116 and EPA 600 / M4-82 / 020 REPORTING LIMIT: <1 % by visual estimation REPORTING LIMIT FOR POINT COUNTS: 0.25% by 400 Points or 0.1 % by 1,000 Points REGULATORY LIMIT: >1% by weight Due to the limitations of the EPA 600 method, nonfriable organically bound materials (NOBs) such as vinyl floor tiles can be difficult to analyze via polarized light microscopy (PLM). EPA recommends that all NOBs analyzed by PLM, and found not to contain asbestos, be further analyzed by Transmission Electron Microscopy (TEM). Please note that PLM analysis of dust and soil samples for asbestos is not covered under NVLAP accreditation. Estimated measurement of uncertainty is available on request. This report relates only to the samples tested or analyzed and may not be reproduced, except in full, without written approval by Eurofins CEI. Eurofins CEI makes no warranty representation regarding the accuracy of client submitted information in preparing and presenting analytical results. Interpretation of the analytical results is the sole responsibility of the client. Samples were received in acceptable condition unless otherwise noted. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. Government. Information provided by customer includes customer sample ID and sample description. ANALYST: APPROVED BY: �a - yan Steele Tianbao Bai, Ph.D., CIH Laboratory Director AMENDED due to Client Wishes to Change ® Specifications for Analysis - Separate Composited Nvt Lavers Laboratory Tvpograr)hical Error - Failed to TESTING NVLAP LAB CODE 101768-0 Page 46 of 46 16Y eurofin5 CHAIN 4F CUSTODY' LAB USE ONLY. 730 SE Maynard Road, Cary, NC 27511 CEI Lab Code: Y4 Tel: 865-481-1412; Fax: 919-481-1442 CEI Lab I.D. Range-' IF TAT IS NOT MARKED STANDARD 3 DAY TAT APPLIES. TURN AROUND TIME ASBESTOS METHOD 4 HR 8 HR 1 DAY 2 DAY 3 DAY 5 DAY PLM BULK EPA 600 ❑ ❑ ❑ ❑ ❑ PLM POINT COUNT (400) EPA 600 ❑ ❑ F-] ❑ ❑ ❑ PLM POINT COUNT (1000) EPA 600 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ PLM GRAY w POINT COUNT EPA 600 PLM BULK CARB 435_ �T ,.. ❑ ❑ ❑ ❑ ❑ PCM AIR NIOSH 7400 ❑ ❑ ❑ ❑ ❑ ❑ TEM AIR EPA AHERA ❑ 0 ❑ ❑ TEM AIR NIOSH 7402 ❑ ❑ ❑ ❑ ❑ TEM AIR (PCME) ISO 10312 ❑ ❑ ❑ ❑ TEM AIR ASTM 6281-15 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ TEM BULK CHATFIELD TEM DUST WIPE ASTM D6480-05 (2010) ❑ ❑ ❑ ❑ ❑ ❑ TEM DUST MICROVAC ASTM D5755-09 (2014) ❑ ❑ ❑ ❑ ❑ ❑ TEM SOIL ASTM D7521-16101 - a� El ❑ ❑ ❑ TEM VERMICULITE CINCINNATI METHOD >;,�.. 111 r ,° ❑ ❑ El TEM QUALITTATIVE IN-HOUSE METHOD _ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ OTHER: REMARKS 1 SPECIAL INSTRUCTIONS. f a� T CS � Accept Samples Reject Samples Relinquished By: Date/Time Received By, Date/Time 1-7CO , Igo c� t1 Samples will be disposed of 30 days after analysis Page of Version: CCOC.01.18.112.LD 35 ASBESTOS S11RV EY FORM AND ANALYTICAL RESIT LTS Inspector name: Gareth Hoffmann 'Ice nse Number: (N�13054 Survey Date: 5117/2021.5/19/Z02I Page � of __V Project Name: South Bank ACM Survey Project Number OMR37IG-00 Location; 400 West Main Street, Durham, NC Sample Number Homogeneous Material Sample Location Condttlon 4uandty Friabiaty Results 1•d 12"x12"Pin k/BrownStreakedFloor Tile Basement Stairwell Good 176ftt Non -Friable arid Mastic 1 12"x 12" Pink/Brown Streaked Floor Tile First Floor Stairwell Good 90 ft: Non -Friable and Mastic 12-x 12" Pink/Brown St reaked Hoar Tile r 1 ; and Mastic Second Floor Stairwell Good Soft, Nan -Friable 1.4 12"x 12" Pink/8rown Streaked Floor Tile Third Floor Stairwell Good 90 ftt Non-Priable a nd ivlast is 2.2 Popcorn Wall Texture Basement NW - Stairwell Good 1.122 fit' Friable 2-2 Popcorn Wall Texture First Floor SE - Stairwell Good 690 ftt Friable 2.3 Popcorn Wall Texture Second Floor SE - Stairwell Good 690 ttz Friable 2.4 Popcorn Wall Texture Third Floor SE • Stairwell Good 690 it, friable 2.5 Popcorn Wall Texture Fourth Floor SE - Stairwell Good 690 it, Friable 2.6 Popcorn Wall Texture Filth Floor SE - Stairwell Good 6901tr Friable 2-j Popcorn Wall Texture Sixth Floor SE - Stairwell Good 690 it, Friable 24a Popcorn Wall Texture Seventh Floor SE • Stairwell Good 690 Fi' friable 2.9 Popcorn wall Texture First Floor NW - Stairwell Good 690 ftr Friatale 3-11 4' Dark Brown Covebase and Adhesive Basement Foyer Between Stairs and Parking Deck Good 270 ft Non•Friable 3.2 4" Dark Brown Covebase and Adhesive Basement Foyer Between Stairs and Parking Deck Good Non -Friable 4 1 12`x12" light Grey Floor Tile and Black Basement Foyer Between Stain and Parking Oeck Gnnd GS6 ftz Non -Friable Mastic 4-2 12"x12" Light Grey Floor Tile and Black Second Floor Server Room • Suite 203 Good 280 it' Non -Friable Mastic 5.1 2' x 2' large and Small Pinhole Ceiling Tile Basement Foyer Between Stairs and Parking Deck Good 656 h' Friable 5.2 2' x 2' Large and Small Pinhole Ceiling Tile First Floor Hallway - North Good 1,000 fit Friable 5.3 2' x 2' Large and Small Pinhole Ceiling Tile Second Floor Hallway Near East Short Stairwell Good 1,000 ftt Friable 5-0 2' x 2' Large and Small Pinhole Ceiling Tile Fourth Floor Hallway in Front of Elevator Good 5,9D0 h' Friable 5-5 2' x 2' Large and Small Pinhole Ceiling Tile Fifth Floor Hallway in Front of Elevator Good 7,0W ftt Friable 5.6 2' a 2' Large and Small Pinhole Ceiling Tile Sixth Floor Hallway En Front of Elevator Good 7,000 ft' Friable 6-1 Brown Stair Tread and Adhesive Basement Stairwell Good 36Stairs Non -Friable 6.2 Brown Stairhead and Adhesive First Floor Stairwell Good 24Sta}rs Non -Friable 6-3 Brown Stair Tread and Adhesive Second Floor Stairwell Good 24 St4l rs Non -Friable 12"x12" Grey wl Black and White Streak 7.3 First Floor lcaBway Storage Room Near Stain Good 491t° Non -Friable Floor Tile and Black Mastic 12"xl2" Grey w/Vack and White Streak 7 2 Second Floor Halway Storage Room Near Stairs Good 4%tt Hon -Friable - Floor Tile and Black Mastic 7.3 12"xl2" Grey wliNack and White Streak Third Floor Hallway Storage Room Near Stairs Good 49ft' Non -Friable Floor Tile and Black Mastic 8.1 Brown Fireproofing Basement Parking Garage -berth Good a33,500 fit Friable 8-2 grown Fireproc4ling Basement Parking Garage - Northeast Good Friable 8.3 Brown Fireproofing Basemeal Parki nj Gar -East Good Friable 84 Brown Fireproofing Basemenr Parki2lGarage- Southeast Good Friable 8.5 Brown Fireproofing Basement Parking Garage - South Good Friable 8-6 Brow n Fireproofing Basement Parking Garage - Southwest Good Friable 7- c"'-- q 8a Brawn Fireproofing Basement Parking Gaza e • west Good Foiabltr 8.8 Brown Fireprooring Basement Parkin Garage - Northwest Goad Friable 8-9. Brown Fireproofing Basement Parking Garage - Northwest on Ground Good Friable 9-1. 10' Pipe Wrap !OraAge) Basement Mechanica(IBofler/Chiller Good 200 It Non -friable 9.2 10" Pipe Wrap (Orange) Basement MechanicalJBoiier/Chiller Good Non -Friable 9.3 10" Pipe Wrap [Orangef Basement Mechanlcal/Bolfer/Chiller Good Nan -Friable 1C.1 10" Pipe Elbow (Orange) Basement MechanIcalySoiler/Chiller Goad 47 Friable 10-2 10" Pipe Elbow (Orange) Basement Mechanical/Boiler/Chiller Good Friable 10.3 IV pipe Elbow (Ora e) Basement Mechankal/Boller/Chiller Good Elhows/Tees Friable 11.1 12' Pipe Wrap {Blue} Basement Mtchankal/8oiler/Chiller Goad 250it Nori4riable 11.2 12' Pipe Wrap (Blue} Basement Mechanical/Boiler/Chiller Good Nan -Friable 11.3 12' Pipe Wrap (Blue) Basement Mechanical/Boiler/Chiller Good Non -Friable 12.1 12" Pipe Elbow (Blue) Basement Mechanical/Bailer/Chiller Goad 37 Friable 12.2 12" Pipe Elbow (Blue) Basement Mechanical/Boiler/Chiller Good Friable 12.3 12" Pipe Elbow 81uc1 Basement A4echankallSoiler/Chiller Good Elbows/Tees Friable 13.1 1.5' Pipe Wrap Basement Mechanical/Boiler/Chiller Good 170 It Ncn-Friable 13-2 1.5" Pipe Wrap Basement Mechartical/Soifer/[hiller Goad Hon -Friable 13.3 1.5' Pipe Wrap Basement Mechancat/Boller/Chiller Good Nan -Friable 14-3 1.5' Pipe Elbow Basement Mechanical/Sailer/Chiller Good 25 Elbows/Tees Friable 14.2 1.5' Pipe Elbow Basement Mechanical/Bailer/Chi[ler Goad Friable 143 I-S'Pipe Elbow Basement Mechancal/$oiler/Chiller Good Friable 15.1 3" Pipe Wrap Basement Mechanical/Boiler/Chiller Goad 120 it Non -friable I5-2 3" Pipe wrap Basement Mechancal/Boller/Chiller Good Non.finable 15.2 1" Pipe wrap Basement Mechanical/Boiler/Chiller Goad Non -Friable 16•a 3" Pipe Elbow Basement Mechanical/Boilef/Chiller Goad 9 Elbows/Tees Friable ITr; 3" Pipe Elbow Basement Mechancal/Sailer/Chiifer Good Friable 16-3 3" Pipe Elbow Basement Mechanical/8oiler/Chiller Good Frlable 17-1 Plaster over CMU First Floor Hallway - North Goad 50,000 fit: Friable 17:2 Plaster over CMU Second Floor Closet Near East Short Stairwell Good Friable 1713 Plaster over CMU First Floor Hallway of Suite 103 Good Friable 174 Plaster over CMU Second Floor Hallway of Suite 206 Goad Friable 175 Plaster over CMU Third Floor Halhyay of Suite 301 Good Friable 1716 Pfa Fter over CMU Fourth Floor Hallway of Suite 401 Good Friable 17.7 Paster over CMU Firth Floor Hallway of Suite 500 Good Friable 17.6 Piaster over CMU Sixth floor H allway, in Front of Efevators Good Friable 17.9 Plaster over CMU Seventh Floor Hallway in Front of Elevators Good Friable 18-1 6" Brawn Covebase and Adhesive First Floor Hallway, - North Good 100 ItNon•Friable 18.2 6" Brown Covebase and Adhesive First Floor Hallway - South Good Non -Friable 19.3 4' Brawn Covebase and Adhesive Fourth Floor Stairwell Good t,000it Non -Friable 19.2 4" Brown Covebase and Adhesive Fifth Floor Stairwell Good Nan -Friable 19.3 4" Brown Covebase and Adhesve Sixth Floor Stairwell Good Non -friable 2E�1 Carpet and Tan Give Cover 12" x 12" Orange and Brawn Trowel Patterned Floor Tite First Floor 103 Storage Room Good 324 fit' Non -Friable 2D-2 Carpet and Tan Glue Over 12" x 12" Orange and Brawn Trowel Patterned Floor The First Floor 103 Storage Roam Good Non -Friable 23-1 4" Black Covebase and Adhesive First Floor ALP Offices Good Non -Friable 21.2 4" Black Covebase and AdheOve Second Floor Mort hwest Corner Ha llWay of Suite 203 Good Non -Friable 213 4' Black Covebase and Adhesive Fourth Floor Suite 406 Breakroom/kitchan Good 375 it Non -Friable 22-1 6' Black Covebase and Adh estve First Floor ALP Offices Good 100 It Non -Friable 22-2 6" Slack Covebase and Adhesive First Floor ALP Offices Good non -Friable 23•11 Black Window Caulk First Floor ALP Offices Good 800 Window Panes l"7,500 ft! Non -Friable 23.2 Black Window Caulk Second Floor Hallway Near East Short Sta l resell Good Non•Friable 23-S Black Window Caulk Fourth Floor Hallway in Front of Elevator Goad Non -Friable 24 j 12"x12' -tan w/ White Streaked Floor Tile and Black Mastic Third Floor Ha[Way tanitoriai Closet Goad 35 N' Non•Frfable 242 12"x12"Tan ndBlackMastile kedFtoar7ife and Black Matti[ Fourth Floor HaI1waylanitorlatCloset Goad 35ft' Hon -Friable 24,3 12"x12"Too w/ Wh lie Streaked F toor Tile and 8la c k Mastic Fifth Floor Ha l lwa y la nit Oral Closet Goad 35 fit Non-Frlabte RZ Ito 25.2 2' x 2' Pinhole and Deep Fissure Ceiling Tile First Floor Suite 101 Good 7D9 ft' Friable 25.2 2' x 2' Pinhole and Deep Fissure Ceiling Tile Third Floor Hallway In Front of 301 Good Friable a3,000 ft' 25.3 2' x 2' Pinhole and Deep Fissure Ceiling Tile Third Floor Hallway in Front of 300•F Good Friable 26"1 4" Cream Covebase and Adhesive First Floor Suite 101 Good 142 it Non -friable 26.2 4" Cream Covebase and Adhesive Fourth Floor Suite 410-412 Good 275 Ft Nan -Friable Carpet With Brown Adhesive Over Leveling Non• 27n Compound First Floor Suite 101 Good TBD Friable/Friable 27"2 Carpet With Brown Adhesive Over leveling First Floor Suite 101 Goad Non_ Compound Friable/Friable 28=1 2' x 2' Textured Pinhole Ceiling Tile Second Floor ALP Suite, Main Room Ceiling Good 624 Fit 28.2 2' x 2' Textured Pinhole Ceiling Tile Second Floor ALP Suite, Main Room Ceiling Good Friable 29.1 Textured Trapezoidal Ceiling The/Panel Second Floor ALP Suite, Main Room Ceiling Goad Friable 3000 Ft? 29.2 Textured Trapezoidal Ceiling Tile/Panel Second Floor ALP Suite, Main Room Ceiling Good Friable 30.1 1' x 1' Pinhole Ceiling Tile First Floor ALP Offices Good 578 ft' Friable aO-2 Vic 1' Plnhde CellingTile Second Floor Server Room - 50le 203 Good 280 k' Friable 31.1 Woad Patterned Sheet Flooring First Floor ALP OF6ces Bathroom Goad Fl 30 r Non -Friable 31.2 Wood Patterned Sheet Flooring First Floor ALP Offices Bathroom Goad Non -Friable 32' v 12' Off-white w/ Plnk Streaked Floor 32-1 Tile and Black Mastic Second Floor Voset Near East Short Stairwell Good 28 ft' Nan -Friable 12' x 12" Off-white w/ Pink Streaked Floor 32.2 The and Black Mastic Second floor Room E Good 81 ft' Hon -Friable 33-t 8" Pipe Elbow ;Fiberglass) with Black Second Floor Room E Goad 'TBD Non•Friable Mastic/Tar Coating {Esllbc mate 10 Non -Friable 33.2 8" Pipe Elbow (Fiberglass) with Black Second Floor Room E Good s Elbows} Mastic/Tar Coating Carpet and Yellow Glue Over 12' x 12'Tan 34.1 Floor Tile and Black Mastic First Floor Suite 103 Good 120 1t' Non**able 34 2 Carpet and Yellow Glue Over 12" x 12' Tan First Floor Suite 103 Good ion -Friable Floor Vile and Black Mastic 35.1 Wallboard First Floor Suite 103 Good 2301t' Friable 35.2 Wallboard Second Floor Office Entrance Suite 203 Good 200 ff' Friable 35.3 Wallboard Third Floor Hallway Closet Near 301 Good �3,000 Ft' friable 35.4 Walibowd Fourth Floor Su Ice 404 Good Friable 36-1 4" Light Tan Covebase and Adhesive Second Floor Hallway of Suite 205 Goad 310 ft Non -Friable 36-1 4" Ught Tan Covebase and Adhesive Fourth Floor Ha [Way of Suite 415 Good 300 ft Nun -Friable 37.1 4" Grey Covebase and Adhesive Fifth floor Ha llw in Front of Suite 500 Good 202 ft Non•Friable 37-2 4" Grey Covebase and Adhesive Fifth Flow Hallway In Front of Janitor Closet Good Non4dable 38.1 2' x 2' Pinhole and Fissure Ceiling Tile Second Floor Office Entrance Suite 203 Good 6,600 ft' Friable 38.2 V x 2• Pinhole and Fissure Ceiling -tile Second Floor Northwest Corner Office Suite 203 Good friable 38-3 Z x 2' Pinhole and Fissure Cell Ing Tile Second Floor Breakroom Suite 203 Good friable 39-1 Carpet and Cream Carpet Glue Second Floor Conference Room Suite 203 Goad 380 ft' Non -Friable 39.2 Carpet and Cream Carpet Glue Second Floor Conference Room suite 2D3 Good Non -Friable 12"x12' White w/ Dark Tan and Black 4G4 Specked Floor Tile and Brown Mastic SKorvd Floor Breakroom Suite 203 Good so x k Non -Friable 12"x12" White w/ Dark Tan and Black 44 2 Specked Floor We and Brown Mastic Second Floor Breakroom Suite 203 Good Non -Friable 41-1 12' x 12' White FWr Tile and Black Mastk Sixth Floor 5twe W9 8reakroom/xitchen Good Non -Friable 167 Ft' 41.2 12' x 12' White Floor Tile and Black Mastic Sixth Floor Suite 609 Breakroom/Kitchen Good Non -Friable 12" x 12" Brown/Tan/Light Brown Blotched 42 1 Floor TBe and Tan Mastic Third Floor Hallway Roam - SE Comer Good 120 it' Non -Friable 12' x 12' Brown/Tan/Light Brown Blotched 42 2 Floor Tile and Tan Mastic Third Floor Southeast Room Good 37D ft' Non-Frlable Q 04 42 3- W* x 12' Brown/TanlLlght Brown Blotched Floor Tile and Tan Mastic Fourth Fkaor Suite 409 Breekroom/Kitchen Gaud lOD h' Non -Friable 43 1. 2' x I' Bumpy large Pinhole and large Fissure Ceiling Tile or Third Flo Hallway Room - SW Corner Good 170 it, Friable 43.2 2' x I' Bumpy Large PinhDie and Large fissure Ceillng Tile Third Floor Suite 300,C Good 352 ft' Friable 43.3. 2' x 2' Bumpy Large PlnfiNe and Large Fissure Ceiling Tile Third Floor Sul to 3DO.E Good 390 h' Friable 44-1 Carpet over 12" x 12" White Floor TRe and Black Mastl c Fourth Floor Suite 404 Gaod 299 h' Non-Friahle 2 Carpet over 32" x 12• White Floor Tile and Black plastic Fourth Floor Suite 401 Good 30D It' Han -Friable 45=1 4• White Covebase Fourth Floor Suite 403 Goad h Non -Friable AS-2 4" White Covebase Fourth Floor Suite 403 Good Non•Friable 46.1 Wallboard and Joint Compound Fourth Floor Suite 406 Breakroom/xitchen Good •ID.DDo ft' Friable 46.2 Wallboard and Joint Compound Fourth Floor Suite 410 GGod Friable 46.3 Wallboard and Joint Compound Fifth Floor Hallway in Front of Suite SOD Good •10ft7 'OOQ Friable 46-4 Wallboard and Joint Compound Fifth Floor Suite SOS Good Friable 46.5 Wallboard and Joint Compound Sixth Floor Suite 614 Good I • I0.0DD It' friable 4" Wallboard and Joint Compound Sixth Poor Suite 602 Good Friable 46.7 Wallboard and Joint Compound Sixth Floor Suite 609 Good Friable 47.1 4' Blue Covebase and Adhesive Seventh Floor Hallway in Front of Mechanical Closet Good 100tt Non -Friable 47.2 4" Blue Covebase and Adhesive Seventh Floor Hallway In Front of 711 Good Non -Friable 48.1 2' x I' Pinhole and Small Fissure Ceiling Tile Fourth Floor Suite 406.409 Gaud 1,375 h' Friable 48.2 2' x 2' Pinhole and Small Fissure Ceiling Tile fourth Floor Suite 406.409 Good Friahle EXT-1.1 Black Window Caulk Second Floor Roof -North Goad 800windvw Panes (773Mft) Nan -Friable EXT-1-2 Black Window Caulk Second Floor Roof -West Good Non -Friable EXT•1.3 Black window CaAA Second Floor Roof -South Good Non4riable UT-2-1 Black Flashing/Seam Caulk Second Floor Roof -No nth Good 60Dft Non -Friable EXT-2.2 Black FWshing/Seam Caulk Second Floor Roof -West Good Non -Friable EXT-2.3 Black Flashing/Sea m Caulk Second Floor Roof -South Good Non -Friable EXT•3-1 Light Grey EapanslonCaulk Second Floor Roof -North Good 2,D00 it Nan -Friable EXT-3.2 light Grey Expansion Caulk Second Floor Roof -West Good Non -Enable EXT-3-3 Light Grey Expansion Caulk Second Poor Roof -South Good Non-Piable EXT•4.1 Silver Caulk on Metal Wrap Seventh Floor Pipes to South Cooling Tower on Roof Good 20 h Non -Friable EXT-4-2 Si Her Caulk on Metal Wrap Seventh Floor Pipes to South Cooling Tower an Roof Good Han-Friahle R•1.1 Roof Membrane Second Floor Roof -North Good I4,p0p fe } Non -Friable R•1.2 Roof Membrane Second floor Roof -West Good Non -Friable R-2.1 Roof Flashing Second Floor ROOF -North Good 720 It: Non -Friable R-2.2 Roof Flashing Second Fluor Roo! -West Good Nan -Friable R•3.1 Roof Membrane Seventh Floor Roof -East Good 7OODhr Nan -Friable R-3-2 Roof Membrane Seventh Floor Roof -North Good Non -Friable R-4-1 Roof Flash in Seventh Floor Roof -East Good Opp It Non•Friable R-4-2 Roof Flashing Seventh Floor Roof -North Good Non -Friable R•5.1 Roof Mc mbrone Penthouse Roof -Center Goad 3,OW It' Nan-Fciablc Condition: Based on a percentage of the building material remain Ing intact at Vme of survey. Friability: Classification of building material's ability to become broken, crushed, or pulva Fired with hand pressure at time of survey. " Quantities are estimated. NOTES: Floor Tiles and Black Ma stic found under tiles may exist 0 other areas of the building not ind uded in quan fifiration estimates. Wallboard and Joint Cam you nd was roughly estimated. Pipe elbow mastic/tar was observed in other floors of the building but was unable to sample due to occu nvy limitations. No Flashing on Penthouse hoof. Carrier, Danielle From: Gareth Hoffmann <GHoffmann@maaonline.com> Sent: Tuesday, May 25, 2021 12:04 PM To: Carrier, Danielle 5obiect: FW: Laboratory Report for 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 Attachments: A216842.pdf "!TERNAL EMAIL* Lastly, for please do not list the first layer as Expansion Caulk. It should be simply Caulk. For here is a black tar layer that should come after the foam/paper layer. From: Gareth Hoffmann Sent: Tuesday, May 25, 2021 11:51 AM To: Carrier, Danielle <Danielle.Carrier@eurofinset.com> Subject: FW: Laboratory Report for 400 W. Main 5t. ACM Survey, 00OR3710.00 - Task 07500 (A216842) Also, please separate wallboard and joint compound layers. From: Gareth Hoffrna:nn Sent: Tuesday, May 25, 2021 11:35 AM To: Carrier, Danielle <Danielle.Carrier@eurofinset.com> Subject: FW: Laboraiory Report for 400 W. Main St. ACM Survey, 00OR3710.00 - Task 07500 (A216842) In reference to he second layer is labelled as CMU; however, the second layer shook. be classi;`ied as rough, coat. (li is Plaster white/skim and grey/rough coat over CMU.) In reerc.-.ca ,•a he layers should be reversed with the black tar coating as layer 1 and the fiberglass pipe elbow as layer 2. The black tar is applied to the outside of the pipe elbow. Pl--csz -ese c,nano-,r a", ;our earliest convenience. Regan as, Gareth h From:: cei@mg.eurofinset.com <cei@mg.eurofinset.com> Seat: Ivicriday, May 24, 2021 3:43 PM APPENDIX C - PHOTOGRAPHS OF ASBESTOS -CONTAINING MATERIALS IS Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 24 Asbestos -Containing 12" x 12" Pink/Brown Streaked Floor Tile and Black Mastic (HA-1) 7 ' Asbestos -Containing Popcorn Wall Texture (HA-2) Asbestos -Containing 12" x 12" Light Grey Asbestos -Containing Brown Stair Tread Floor Tile and Black Mastic (HA-4) (HA-6) IS Mid Atlantic NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina June 11, 2021 Page 25 rLT 1' t i Asbestos -Containing 12" x 12" Orange and Brown Trowel -Streak -Patterned Floor Tile and Black Mastic Under Carpet and Tan Glue (HA-20) Mr x Asbestos -Containing 12" x 12" Off -White with Pink/Streaked Floor Tile and Black Mastic (HA-32) Asbestos -Containing 12" x 12" Tan with White Streaked Floor Tile and Black Mastic (HA-24) Asbestos -Containing Black Mastic/Tar Coating on 8" Fiberglass Pipe Elbows (HA-33) IS Mid Atlantic June 11, 2021 Page 26 NESHAP Asbestos Survey Report 400 West Main Street Durham, North Carolina r= _ Asbestos -Containing Black Mastic Asbestos -Containing Black Mastic (Fourth Associated 12" x 12" Tan Floor Tile Floor Exclusively) Associated with 12" x Under Carpet and Yellow Glue 12" Brown/Tan/Light Brown Blotched Floor (HA-34) Tile and Tan Mastic (HA-42) ya.. 7i5• . Asbestos -Containing 12" x 12" White Floor Tile and Black Mastic Under Carpet and Yellow Mastic (HA-44) Asbestos -Containing 12" x 12" Grey with Black and White Streaked Floor Tile and Black Mastic (HA-7) IS Mid Atlantic APPENDIX D - NORTH CAROLINA ASBESTOS INSPECTOR CERTIFICATIONS I* Mid Atlantic North Carolina Asbestos Accreditation -'W- "T-% I 12-31-2021 08-26-1992 M 5'3" 185 AIR MONITOR 80889 12-21 INSPECTOR 13054 12-21 Gareth M Hoffmann 36048 Ellen Rd New London, NC 28127 131085