Loading...
HomeMy WebLinkAboutWS-29656_48783_CA_UST-61_20221209 UST-61 24-Hour Release and UST Leak Reporting Form. For Releases in NC This form should be completed and submitted to the UST Section’s regional office following a known or suspected release from an underground storage tank (UST) system. This form is required to be submitted within 24 hours of discovery of a known or suspected release (DWM USE ONLY) Incident # ________ Risk (H,I,L,U)_______ Received On ________ Received By ________ Reported by (circle one): Phone, Fax or Report Region _______ INCIDENT DESCRIPTION Raleigh, Washington, Wilmington, Winston-Salem Briefly describe suspected or confirmed release: (including but not limited to: nature of release, date of release, amount of release, amount of free product present and recovery efforts, initial responses conducted, impacts to receptors)  GPS  Other  Unknown Describe location: HOW RELEASE WAS DISCOVERED (Release Code) (Check one)  Release Detection Equipment or Methods  During UST Closure/Removal  Property Transfer  Visual/Odor  Water in Tank  Water Supply Well Contamination  Groundwater Contamination  Surface Water Contamination  Other (specify) _______________ SOURCE OF CONTAMINATION Source of Release (Check primary source) Cause of Release (Check primary cause) Type of Release (Check one) Product Type Released (Check primary product type released)  Tank  Piping  Dispenser  Submersible Turbine Pump  Delivery Problem  Spill Bucket  Other  Unknown Definitions presented on reverse  Spill  Overfill  Corrosion  Physical/Mechanical Damage  Install Problem  Other  Unknown Definitions presented on reverse  Petroleum  Non-Petroleum  Both Location (Check one)  Facility  Residence  Other  Gasoline/ Diesel/ Kerosene  Heating Oil  Other Petroleum Products  Metals  Other Inorganics  Other Organics  Diesel/Veg. Oil Blend  Vegetable Oil 100%  E10 – E20  E21 – E84  E85 – E99  Ethanol 100%  E01 – E09 Ownership 1. Municipal 2. Military 3. Unknown 4. Private 5. Federal 6. County 7. State Operation Type 1. Public Service 2. Agricultural 3. Residential 4. Education/Relig. 5. Industrial 6. Commercial 7. Mining UST Form 61 (02/19) Page 1 of 2 Suspected Contamination? (Y/N) _N_______ Confirmed GW Contamination? (Y/N) ___N___ Confirmed Soil Contamination ?(Y/N) ___Y___ Samples Taken?(Y/N) ___Y___ Free Product? (Y/N) ___N__ If Yes, State Greatest Thickness _______NA_______ Facility ID Number ______________ Date Leak Discovered _12/9/2022__ Comm/Non-Commercial? _Comm__ Reg/Non-regulated? _______Reg___ Regional Office (circle one): Asheville, Mooresville, Fayetteville, City/Town: Greensboro Zip Code: 27407 Address: 4411 Groometown Road County: Guilford Incident Name: TForce Greensboro, NC Facility Latitude (decimal degrees): 35.9958817 Longitude (decimal degrees) : -79.8631032 Obtained by:  GIS Address matching  Topographic map IMPACT ON DRINKING WATER SUPPLIES Water Supply Wells Affected? 1. Yes 2. No 3. Unknown Number of Water Supply Wells Affected __________________ Water Supply Wells Contaminated: (Include Users Names, Addresses and Phone Numbers. Attach additional sheet if necessary) 1. 2. 3. UST SYSTEM OWNER UST Owner/Company Point of Contact Address City State Zip Code Telephone Number UST SYSTEM OPERATOR UST Operator/Company Address City State Zip Code Telephone Number LANDOWNER AT LOCATION OF UST INCIDENT Landowner Address City State Zip Code Telephone Number Draw Sketch of Area (showing two major road intersections) or Attach Map Person Reporting Incident Company Telephone Number Title Address Date UST Form 61 (02/19) Page 2 of 2 Definitions of Sources Tank: means the tank that stores the product and is part of the underground storage tank system Piping: means the piping and connectors running from the tank or submersible turbine pump to the dispenser or other end-use equipment (Vent, vapor recovery, or fill lines are excluded.) Dispenser: includes the dispenser and the equipment used to connect the dispenser to the piping (e.g., a release from a suction pump or from components located above the shear valve) Submersible Turbine Pump (STP) Area includes the submersible turbine pump head (typically located in the tank sump), the line leak detector, and the piping that connects the submersible turbine pump to the tank Delivery Problem: identifies releases that occurred during product delivery to the tank. (Typical causes associated with this source are spills and overfills.) Other: serves as the option to use when the release source is known but does not fit into one of the preceding categories (e.g., for releases from vent lines, vapor recovery lines, and fill lines) Unknown: identifies releases for which the source has not been determined Definitions of Causes Spill: use this cause when a spill occurs (e.g., when the delivery hose is disconnected from the tank fill pipe or when the nozzle is removed from the dispenser) Overfill: use when an overfill occurs (e.g., overfills may occur from the fill pipe at the tank or when the nozzle fails to shut off at the dispenser) Physical or Mechanical Damage: use for all types of physical or mechanical damage, except corrosion (e.g., puncture of tank or piping, loose fittings, broken components, and components that have changed dimension) Corrosion: use when a metal tank, piping, or other component has a release due to corrosion (e.g., for steel, corrosion takes the form of rust) Installation Problem: use when the problem is determined to have occurred specifically because the UST system was not installed properly Other: use this option when the cause is known but does not fit into one of the preceding categories (e.g., putting regulated substances into monitoring wells) Unknown: use when the cause has not been determined DATE: APPROVED BY: CHECKED BY: DRAWN BY:PROJ. NO.:Path:Plot Date:DECEMBER 2022 463648.0000.0000 Figure_1_Soil_Analytical_Data_Greensboro.mxd TFORCE HOLDINGS USA, INC.4411 GROOMETOWN ROADGREENSBORO, NORTH CAROLINA D. SZYNAL U:\TForce\Greensboro, NC\2022\Figure_1_Soil_Analytical_Data_Greensboro.mxd12/9/2022, 13:01:50 PM by DSZYNAL -- LAYOUT: ANSI B(11"x17")Map Rotation:Coordinate System:0NAD 1983 StatePlane South Carolina FIPS 3900 Feet (Foot US)L. CLARK 1:3001 " = 25 ' 0 25 50Feet µ LEGEND TRC - GISTRC - GISFIGURE 1 J. YONTS SOIL ANALYTICAL RESULTS FILE NO.: TITLE: PROJECT: NOTES:1. © 2022 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS 2. Soil analytical result exceedances above comparison values.3. Soil sample results expressed in mg/kg4. NAP = Naphthalene5. 1-MN = 1-Methylnaphthalene6. 2-MN = 2-Methylnaphthalene7. TPH-DRO = Total Petroleum Hydrocarbons - Diesel Range Organics8. TPH-GRO = Total Petroleum Hydrocarbons - Gasoline Range Organics WORKING COPY Patewood Plaza Three, Suite 15050 International DriveGreenville, SC 29615-3535Phone: 864-281-0030FAX: 864-281-0288 Approximate location and Extent of Excavation of Former Fuel Dispensers Approximate Extent of Excavation Former Diesel Fuel Pipe and Vent Lines Soil Sample Location Approximate location of Former20,000-gallon Diesel UndergroundStorage Tank DATE: APPROVED BY: CHECKED BY: DRAWN BY:PROJ. NO.:Path:Plot Date:DECEMBER 2022 463648.0000.0000 Figure_1_Soil_Analytical_Data_Greensboro.mxd TFORCE HOLDINGS USA, INC.4411 GROOMETOWN ROADGREENSBORO, NORTH CAROLINA D. SZYNAL U:\TForce\Greensboro, NC\2022\Figure_1_Soil_Analytical_Data_Greensboro.mxd12/9/2022, 13:01:50 PM by DSZYNAL -- LAYOUT: ANSI B(11"x17")Map Rotation:Coordinate System:0NAD 1983 StatePlane South Carolina FIPS 3900 Feet (Foot US)L. CLARK 1:3001 " = 25 ' 0 25 50Feet µ LEGEND TRC - GISTRC - GISFIGURE 1 J. YONTS SOIL ANALYTICAL RESULTS FILE NO.: TITLE: PROJECT: NOTES:1. © 2022 Microsoft Corporation © 2022 Maxar ©CNES (2022) Distribution Airbus DS 2. Soil analytical result exceedances above comparison values.3. Soil sample results expressed in mg/kg4. NAP = Naphthalene5. 1-MN = 1-Methylnaphthalene6. 2-MN = 2-Methylnaphthalene7. TPH-DRO = Total Petroleum Hydrocarbons - Diesel Range Organics8. TPH-GRO = Total Petroleum Hydrocarbons - Gasoline Range Organics WORKING COPY Patewood Plaza Three, Suite 15050 International DriveGreenville, SC 29615-3535Phone: 864-281-0030FAX: 864-281-0288 Approximate location and Extent of Excavation of Former Fuel Dispensers Approximate Extent of Excavation Former Diesel Fuel Pipe and Vent Lines Soil Sample Location Approximate location of Former20,000-gallon Diesel UndergroundStorage Tank