Loading...
HomeMy WebLinkAboutWS-28030_47427_CA_LSA_20230113     TABLE OF CONTENTS      1.0 FACILITY INFORMATION ..................................................................... 1  2.0 INTRODUCTION .................................................................................. 1  3.0 SITE HISTORY ...................................................................................... 2  3.1 UNDERGROUND STORAGE TANK INFORMATION: .............................................. 2  3.2 SOIL ASSESSMENT & UST CLOSURE ACTIVITIES SUMMARY ................................ 3  4.0 RISK CHARACTERIZATION ................................................................... 4  5.0 RECEPTOR INFORMATION .................................................................. 4  5.1 WATER SUPPLY WELLS:.............................................................................. 4  5.2 PUBLIC WATER SUPPLIES ARE NOT AVAILABLE ................................................ 4  5.3 SURFACE WATER: ..................................................................................... 5  5.4 WELLHEAD PROTECTION AREAS: .................................................................. 5  5.5 DEEP AQUIFERS IN THE COASTAL PLAIN PHYSIOGRAPHIC REGION: ....................... 5  5.6 SUBSURFACE STRUCTURES: ......................................................................... 5  5.7 LAND USE: .............................................................................................. 5  6.0 SITE GEOLOGY AND HYDROGEOLOGY ................................................. 5  7.0 GROUNDWATER INVESTIGATION ....................................................... 6  7.1 MONITORING WELL INSTALLATION: .............................................................. 6  7.2 MONITORING WELL AND SUPPLY WELL SAMPLING & LABORATORY ANALYSES: ...... 6  7.3 GROUNDWATER FLOW DIRECTION ................................................................ 7  7.4 GROUNDWATER ANALYTICAL RESULTS: .......................................................... 7  8.0 ASSESSMENT SUMMARY .................................................................... 8  9.0 RECOMMENDATIONS ......................................................................... 9  10.0 CLOSURE ......................................................................................... 9      Page  I TABLE OF CONTENTS  (Continued)      FIGURES:    1. USGS Topographic Map  2. Site Detail Map  3. UST Closure Map (November 2020)  4. Surrounding Properties/Supply Well Locations Map  5. Potentiometric Surface Map (10‐13‐2022)  6. Benzene Isoconcentration Map (10‐13‐2022)  7. Toluene Isoconcentration Map (10‐13‐2022)  8. Ethylbenzene Isoconcentration Map (10‐13‐2022)  9. Xylenes Isoconcentration Map (10‐13‐2022)  10. MTBE Isoconcentration Map (10‐13‐2022)      TABLES:    1. UST Information (Page 2)  2. UST Closure Samples – TPH Soil Results  3. RedLabs Soil Analytical Results (Diesel & Kerosene USTs)  4. Post‐Excavation Risk‐Based Soil Analytical Results (Diesel)  5. Surrounding Properties within 1,000 ft. of source area  6. Monitoring Well Construction Data  7. LSA Risk‐Based Soil Analytical Results  8. Groundwater Gauging Data  9. Groundwater Analytical Results    APPENDICES:    A. Notice of Regulatory Requirements  B. LSA Risk Classification & Land Use Form  C. Field Drilling & Well Construction Records   D. Standard Field Procedures  E. Laboratory Report for Soil & Groundwater Samples    Page II Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 1  Pyramid Project # 2021‐080  01/13/2023     LIMITED SITE ASSESSMENT ( LSA II )  REPORT  C&H SHELL  WEST JEFFERSON, ASHE COUNTY, NC 28643      1.0 FACILITY INFORMATION     Site Name:    C & H Shell        Location:    317 S. Jefferson Ave., West Jefferson, NC   Site Detail Information: Figure 1 (Topo Map), Figure 2 (Site Detail Map)   DEQ  Incident No.:  45130   Facility I.D. No.:  00‐0‐0000022991 ( all USTs removed 2020)   UST Owner/Operator:  Colvard Oil Company ( all USTs removed 2020)   Responsible Party:  Colvard Oil Company  Mr. Larry Dollar, President  P.O. Box 7, West Jefferson, NC 28694‐0007   Consultant/Contractor: Pyramid Environmental & Engineering, P.C.   Release Information:  a. Date Discovered: November 2020  b. Est. Qty. of Release: Unknown  c. Source of Release: Gasoline and Diesel UST System  d. UST Size/Contents: See Table 1  e. Latitude/Longitude: N. Lat.  36.399059⁰  /  W. Long.  ‐81.490904⁰     Property Owner:  Colvard Oil Company  Mr. Larry Dollar, President  P.O. Box 7, West Jefferson, NC 28694‐0007   Current Property Use:  Colvard Oil Company main office   UST Owners:      Colvard Oil Company    2.0 INTRODUCTION    On behalf of Colvard Oil Company, Pyramid Environmental & Engineering P.C. (Pyramid)  has completed the Phase II Limited Site Assessment (LSA II) for the former C&H Shell  (Colvard Oil Co. Office) property. The subject property is located at 317  S. Jefferson  Avenue in West Jefferson, Ashe County, North Carolina. The location of the site is shown  on Figure 1, portions of the Jefferson, NC, USGS topographic map.     Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 2  Pyramid Project # 2021‐080  01/13/2023  Two 1,000‐gallon gasoline Underground Storage Tanks (USTs) and one 3,000‐gallon  diesel UST were installed on the property in 1972 and used until 2010. Two 1,000‐gallon  diesel and one 550‐gallon kerosene USTs were installed on the property in 1985 and  used until 2010. An orphaned 1,000‐gallon gasoline UST was found during the UST tank  removal and the dates of use are unknown. During November 4 ‐ 6, 2020, Pyramid  supervised the removal and permanent closure of the seven USTs. During the UST  removals in 2020, petroleum releases from the four gasoline USTs were confirmed, and  were reported to the NC Department of Environmental Quality (DEQ).  The former  locations of the USTs are shown on Figure 2.     3.0 SITE HISTORY    3.1 Underground Storage Tank Information:  Details of the UST are included in Table 1.    Table 1  UST Information    Tank  No.  Install  Date  Size in  (Gals)  Tank  Dimensions  Last  Contents  Permanently Closed/Removed   T1 5/11/1972 1,000 4’ dia. x 10’8” L Gasoline Removed 11/2020 – Release Confirmed  T2 5/11/1972 1,000 4’ dia. x 10’8” L Gasoline Removed 11/2020 – Release Confirmed  T3 5/11/1972 3,000 5’ 3” dia. x 18’ L Gasoline Removed 11/2020 – Release Confirmed  T4 5/11/1985 1,000 5’3”dia. x 6’2” L Diesel No release – Removed on 11/5/2020  T5 5/11/1985 1,000 5’3”dia. x 6’2” L Diesel No release – Removed on 11/5/2020  T6 5/11/1985 550 3’10”dia x 6’1”L Kerosene No release – Removed on 11/5/2020  T7 ?? 1,000 4’ dia. x 10’8” L Gasoline Removed 11/2020 ‐ Release Confirmed    As indicated on Table 1, three 1,000‐gallon gasoline underground storage tanks (USTs),  one 3,000‐gallon gasoline UST, two 1,000‐gallon diesel USTs, and one 550‐gallon  kerosene UST were closed by removal. The gas station building is approximately 1,300  square feet and there is an inactive car wash. The Site Map showing the UST area is  presented as Figure 2, and shows the layout and general site features.    Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 3  Pyramid Project # 2021‐080  01/13/2023  3.2 Soil Assessment & UST Closure Activities Summary  On November 4 ‐ 6, 2020, Pyramid supervised the removal and permanent closure of  three (3) 1,000‐gallon gasoline underground storage tanks (USTs), one (1) 3,000‐gallon  gasoline UST, two (2) 1,000‐gallon diesel UST, and one 550‐gallon diesel UST at the C&H  Shell site.  As part of the permanent closure of the UST systems and Initial Abatement  Actions, 51.5 tons of petroleum‐impacted soil were excavated and transported off‐site  for proper treatment and disposal.    The soil samples collected beneath the three gasoline USTs contained concentrations of  GRO and DRO that exceed the current NCDEQ initial cleanup levels for GRO of 50  milligrams per kilogram (mg/kg), and DRO of 100 mg/kg. The laboratory results for the  product line and dispenser soil samples detected TPH concentrations that exceed the  current DEQ initial cleanup levels. The locations of the initial UST closure samples are  shown on Figure 3, and the laboratory results are summarized in Table 2.     The soil samples collected beneath the two diesel USTs, did not contain concentrations  of GRO and DRO that exceed the current NCDEQ initial cleanup levels for GRO of 50  milligrams per kilogram (mg/kg), and DRO of 100 mg/kg.    The Soil samples collected beneath the kerosene UST, did not contain concentrations of  GRO and DRO that exceed the current NCDEQ initial cleanup levels for GRO of 50  milligrams per kilogram (mg/kg), and DRO of 100 mg/kg.    The contaminated soil above, around, and below the gasoline, diesel, and kerosene  tanks was excavated.  Most of the petroleum‐impacted soil detected around USTs were  excavated.  The soil excavations are shown on Figure 3.  The final excavation  dimensions, sample depths, and sample locations are shown on Figure 3.  The post‐ excavation soil samples for the gasoline excavation were analyzed for volatile organic  compounds (VOCs) using EPA Method 8260/5035.     A shown in Table 3 and Table 4, some the targeted risk‐based parameters were  detected at concentrations that exceed the soil‐to‐groundwater maximum soil  contaminant concentrations (MSCCs). The results were below residential MSCCs in the  gasoline post‐excavation soil samples.    Based on the remaining soil contaminants, and the shallow groundwater at the site, the  NC DEQ issued a Notice of Regulatory Requirements to Colvard Oil. The DEQ letter  required the preparation and submittal of a Limited Site Assessment Report for  regulatory Incident # 47247. The NCDEQ letter dated August 25, 2021 is presented as  Appendix A.   Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 4  Pyramid Project # 2021‐080  01/13/2023  4.0 RISK CHARACTERIZATION    The LSA Risk Classification and Land Use Form was completed by Pyramid and is  presented as Appendix B.  The receptors survey located one active municipal water  supply well (Well 7A) within 1,000 feet of the former gasoline and diesel UST systems.   The area is supplied with drinking water by drilled water supply wells operated by the  town of West Jefferson, and some uphill up‐gradient spring‐fed water supply sources  operated by the Town as well. Pyramid did not observe any private water supply wells  during the receptor survey.  The results of the LSA indicate that the incident should be  classified as “high‐risk” since there is an active water supply well located within 1,000  feet of the source area.     5.0 RECEPTOR INFORMATION    In 2022, Pyramid completed a receptor survey for the former C&H Shell. The site is  located in downtown West Jefferson, where all properties within 1,500 feet use  municipal water provided by the Town of West Jefferson. Pyramid completed the  receptor survey in May 2019 by walking and interviewing some of the property owners  located within 1,000 feet of the site.  The surrounding area is shown on Figure 4. The  property owner and supply well information for the properties within approximately  1,000 feet are provided in Table 5.     A search for supply wells found only one municipal water supply well location within  1,000 feet of the site, as shown on Figure 4.     5.1 Water Supply Wells:  As shown on Figure 4, no private water supply wells and springs were identified within  1,000 feet of the site. One public water supply well (MW‐7A is located approximately  950 feet to the northwest and is shown on Figure 4.     5.2 Public Water Supplies are Not Available   The subject site and all properties within 1,500 feet of the site rely on the Town of West  Jefferson for potable water supply.    Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 5  Pyramid Project # 2021‐080  01/13/2023  5.3 Surface Water:  The nearest surface water is Little Buffalo Creek, which is located under the site.  The  surface water run‐off on the subject site generally flows to the east towards Little  Buffalo Creek.      5.4 Wellhead Protection Areas:  The area surrounding the site is within the West Jefferson designated wellhead  protection area.    5.5 Deep Aquifers in the Coastal Plain Physiographic Region:  This site is not in the Coastal Plain; therefore, this section does not apply to this site.    5.6 Subsurface Structures:  The culvert for stormwater beneath the site is the only known subsurface structure  located in the source areas.    5.7 Land Use:  The area near the subject site is primarily commercial and industrial properties with  some nearby residential properties. The nearest residential properties are  approximately 430 feet to the east southeast.    6.0 SITE GEOLOGY AND HYDROGEOLOGY    Pyramid’s review of the 1985 Geologic Map of North Carolina yielded information  concerning local geology and hydrogeology. Based on this review, the site is in the Blue  Ridge Belt of North Carolina. The surface geology consists of regional soils created by  the weathering of the underlying bedrock. According to the 1985 Geologic Map of North  Carolina, the underlying bedrock beneath the site includes Equigranular, massive to well  foliated, interlayered, rarely discordant, metamorphosed intrusive and extrusive mafic  rock, map symbol Zata.    In general, both surface and groundwater flow directions are controlled by topographic  contours of landforms, with flow occurring perpendicular to the contours from high to  low elevations. At the C&H Shell Site, there is a box culvert which contains an active  surface water stream. The on‐site stream flows about 0.5 miles into Little Buffalo Creek,  Surface water from the subject enters the storm drains and flows northeast into Little  Buffalo Creek which is shown in Figure 1.  Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 6  Pyramid Project # 2021‐080  01/13/2023  7.0 GROUNDWATER INVESTIGATION    7.1 Monitoring Well Installation:  To investigate groundwater in the three UST system areas, Pyramid installed three 2‐ inch diameter monitoring wells on October 12, 2022.  The wells (MW‐1, MW‐2 and MW‐ 3) were installed to a depth of 15 feet BLS.  The MWs were drilled using a truck‐ mounted drill rig and installed with solid stem augers. The wells were constructed using  10 feet of 2‐inch diameter schedule‐40 PVC 0.010‐inch slotted screen, and the  remaining portion was constructed of schedule 40 PVC solid well casing.      Monitoring wells MW‐1 was installed downgradient of the former dispenser island and  MW‐2 was installed near the former 3,000‐gallon gasoline UST. Monitoring well MW‐3  was installed next to the two former 1,000‐gallon diesel USTs on the downgradient side  of the site. The location of the monitoring wells are shown on Figure 2.  The well  construction data for the monitoring wells are included in Table 6, and a copy of the  well construction records and soil boring logs are presented in Appendix C.     During the installation of each monitoring well, soil samples were screened in the field.  The soil sample with the highest PID reading from each well was collected for risked‐ based laboratory analyses.  The laboratory results for soil sample MW‐1(5‐6’) and MW‐ 2(5‐6’) detected some of the targeted risk‐based parameters above soil‐to‐groundwater  MSCC levels but below residential MSCCs.  NO Soil samples were collected for Risk‐ Based analyses from MW‐3 since the GRO and DRO concentrations in that area were  below cleanup levels.  The laboratory results are summarized in Table 7. The soil sample  laboratory report is included in Appendix D.    7.2 Monitoring Well and Supply Well Sampling & Laboratory Analyses:  On October 13, 2022, groundwater samples were collected from monitoring wells MW‐ 1, MW‐2 and MW‐3 for laboratory analyses. Prior to collecting the groundwater  samples, the monitoring wells were gauged to record the depth to groundwater and  check for free product. No free product was detected in any of the monitoring wells.   The depth to groundwater ranged from 7.36 to 7.71 feet below the top‐of‐casing (TOC).  The site is in a river valley and the groundwater is shallow.     To purge stagnant water and develop each monitoring well, approximately 2 to 4   gallons of water was removed from each well using disposal bailers. The standard field  procedures used by Pyramid are summarized in Appendix D.  The groundwater samples  were collected using the disposable bailer and placed in laboratory prepared containers,  packed in ice, and prepared for shipment to Pace Analytical Services in Huntersville, NC.   Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 7  Pyramid Project # 2021‐080  01/13/2023    The groundwater samples from monitoring wells MW‐1, MW‐2, and MW‐3 (from the  gasoline area) were collected for gasoline methods, and analyses included EPA Method  6200B for volatile organic compounds (VOCs),  Method 504.1 for 1,2‐Dibromomethane  (EDB), and EPA Method 6010 for lead (Pb).  All groundwater concentrations are  reported in Micrograms per liter (µg/l).    7.3 Groundwater Flow Direction  On October 13, 2022, Pyramid conducted an elevation survey to establish the relative  top of casing (TOC) elevations for the groundwater monitoring wells. Groundwater  elevation data recorded in the field was used with the relative elevation survey data  from the monitoring wells to calculate the relative groundwater elevation for each well.   The TOC elevation data from the survey and depth‐to‐groundwater measurements are  presented on Table 8 with the calculated groundwater elevation at each MW.      Utilizing the calculated relative groundwater elevation data for the Type II monitoring  wells, a potentiometric surface map was prepared for the site and is presented as Figure  5.  The groundwater contours show groundwater flow to the northeast with the surface  water stream toward Little Buffalo Creek. This flow direction concurs with the local  topography and stream flow. No Free‐Product was found in any of the MWs.    7.4 Groundwater Analytical Results:  The laboratory results of the groundwater sample collected from MW‐1 on October 13,  2022 showed concentrations of benzene at 11.9 micrograms per liter (ug/L). The  benzene concentration in MW‐1 is above the North Carolina Administrative Code  (NCAC) 2L Groundwater Standard for benzene and just greater than 10 times the  drinking water standard. The remaining wells did not have any compounds above the  NCAC  2L groundwater standards.     The laboratory results for the groundwater samples collected in October 2022 are  summarized on Table 9, and a copy of the laboratory report and chain of custody is  presented as Appendix E.  Groundwater concentration contours were prepared for  BTEX compounds and MTBE and are presented as Figures 6‐10, respectively. These  analytical data and concentration contours show a relatively small area of benzene  concentrations above NCAC 2L groundwater standards. Naphthalene and n‐ butylbenzene were slightly above the NCAC 2L standard but well below NC Gross  Contaminant Limits (GCLs).      Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 8  Pyramid Project # 2021‐080  01/13/2023  8.0 ASSESSMENT SUMMARY    As requested by Colvard Oil Company, Inc., Pyramid has completed the Phase II Limited  Site Assessment (LSA II) for the former C&H Shell in West Jefferson, NC.  A summary of  the assessment results is presented below.     In November 2020, Pyramid supervised the removal of the former C&H Shell  gasoline UST systems, diesel USTs, kerosene UST, and associated product piping.     On November 4, 2020, approximately 20 gallons of dark gasoline free‐product was  vacuumed from beneath the Orphaned gasoline UST excavation. The free‐product  was a dark, old gasoline, and did not return to the excavation after it was pumped  out once. To further remediation the pump island area, this area was excavated on  November 5th, and approximately 12.56 tons petroleum contaminated soil was  removed from the bottom of the pump island/gasoline tank excavation.      Approximately 51.5 tons of petroleum contaminated soil was removed from the site  during the UST removal process.      On October 12, Pyramid installed three groundwater monitoring wells (MW‐1, MW‐ 2, and MW‐3) in the three source areas at the site.      Risk‐based soil analytical results showed Benzene in MW‐1 and MW‐2 at levels  which exceed the soil‐to‐groundwater MSCCS but are below the residential MSCCs.      Risk‐based soil analytical results showed Tetrachloroethene in MW‐3 at levels which  exceed the soil‐to‐groundwater MSCCS but are below the residential MSCCs.     The water table at the site is between 7.36 and 7.71 feet BLS.      The receptors survey showed that all developed properties within 1,000 feet of the  site rely on the Town of West Jefferson for water supply. One public water supply  well (MW‐7A) is located approximately 950 feet to the northwest of the site.     The nearest surface water is a tributary to Little Buffalo Creek. The tributary runs  beneath the site in a box culvert. The nearest surface water is at the site.       The risk classification of the incident should be “High Risk”.    Based on the findings of this LSA II, the concentrations detected in the monitoring wells  are relatively low and do not pose an imminent threat to any supply well. Additional  monitoring and groundwater assessment is recommended.    Colvard Oil Company, Inc. – C&H Shell –  Limited Site Assessment (LSA II) 9  Pyramid Project # 2021‐080  01/13/2023    9.0 RECOMMENDATIONS    As requested by Colvard Oil Company, Pyramid completed the LSA II and risk evaluation  for the C&H Shell in West Jefferson, NC. Based on the findings and evaluation of the  assessment data, Pyramid recommends the following:     Installation of one additional groundwater monitoring well to the northwest of  MW‐1 to define the groundwater concentrations of benzene at the site. This well  will be installed and surveyed to provide a relative TOC elevation.     After the proposed MW is installed, we recommend gauging all wells and  collecting a full round of groundwater samples from all MWs.         10.0 CLOSURE    This report is prepared for, and made available solely for the use of Colvard Oil  Company, Inc. and the NCDEQ.  The contents thereof may not be used or relied upon by  any other person without the express written consent and authorization of Pyramid  Environmental & Engineering, P.C. (Pyramid). The scope of services for this  environmental report relies on documented environmental data provided by others.  The NCDEQ accepted the previous environmental investigations; therefore, these  reports are counted as reliable in providing historical data for the evaluations in this  report. The subsurface is inherently heterogeneous and subsurface conditions not  identified in this limited assessment may influence COCs in unpredicted ways.  Subsurface conditions such as groundwater elevations, groundwater migration, and  water quality will vary over time. The opinions and conclusions in this report are in  accordance with industry accepted geologic and hydrogeologic practices used at the  time and location where the report was prepared. No guarantee or warrantee is  expressed or implied. The observations, conclusions, and recommendations  documented in this report are based on site conditions and information reviewed at the  time of Pyramid's investigation. Pyramid appreciates the opportunity to provide this  environmental service.                                FIGURES      Well #7A 1,000' Radius Figure 4 Receptor Survey Map C&H Shell West Jefferson, NC 5 6 7 8 9 10                               TABLES      SAMPLE DATE Soil Sample DEPTH FID/OVA GRO (mg/kg) DRO (mg/kg) ID Location (feet) (ppm) (C5 - C10) (C10-C35) PI1 11/3/2020 Gasoline Dispener 1.5 150.0 2157 4226 PI2 11/3/2020 Gasoline Dispener 1.5 123.0 145.5 219.5 PI3 11/3/2020 Gasoline Dispener 1.5 12.0 <0.42 13.1 #1S 11/4/2020 Under South End 1,000 gallon Gasoline UST 7 540.0 1566.0 2676.0 #1N 11/4/2020 Under North End 1000 gallon Gasoline UST 6.5 - 7 580.0 69.8 494.9 #2S 11/4/2020 Under South End 1,000 gallon Gasoline UST 7 190.0 438.2 910.2 #2N 11/4/2020 Under North End 1000 gallon Gasoline UST 7 190.0 64 106.7 UNTN 11/4/2020 Under North End 1000 gallon Gasoline UST 7 390.0 112.8 491.1 UNTS 11/4/2020 Under South End 1,000 gallon Gasoline UST 7 800.0 109.3 285.8 LS1 11/4/2020 Gasoline Product Line Sample 2 - 2.5 675.0 1324 3101 LS2 11/5/2020 Gasoline Product Line Sample 2 - 3 5.0 <0.67 53.2 LS3 11/5/2020 Gasoline Product Line Sample 2 - 3 4.6 <1.2 89.6 LS4 11/6/2020 Gasoline Product Line Sample 2 - 2.5 0.2 <0.58 25.2 3KGW 11/6/2020 Under West End 3,000 gallon Gasoline UST 8 - 9 9.2 18.7 6.4 3KGE 11/6/2020 Under East End 3,000 gallon Gasoline UST 8 - 9 3.1 <0.54 11.1 DS1 11/3/2020 Composite Soil Sample NA 575 74.9 214.1 FID= flame-ionizaton detector GRO= Gasoline Range Organics TPH= Total Petroleum PPM= parts-per-million DRO= Diesel Range Organics Hydrocarbons (GRO + DR PID= Photoionization Detector mg/kg= milligrams-per-kilogram NA= Not Applicable HC= Hydrocardons "------" = No Laboratory Analysis PHC= Petroleum Hydrocarbons * Bold values indicate concentrations above NCDEQ initial action levels Composite Soil Sample of Overburden / Stockpile 100NC Initial Action Level - UST Section for 505035/5030-GRO; 3550-DRO TABLE 2 Summary of UST Closure Soil Sample Results For Gasoline USTs Former C & H Shell - Colvard Oil Company Offices 317 S. Jefferson Ave. West Jefferson, Ashe County, North Carolina SAMPLE DATE Soil Sample DEPTH FID/OVA GRO (mg/kg) DRO (mg/kg) ID Location (feet) (ppm) (C5 - C10) (C10-C35) DP1 11/3/2020 Diesel Dispener 1.5 9.0 <0.74 16.9 DP2 11/3/2020 Diesel Dispener 1 0.7 <0.68 8.5 D1E 11/5/2020 Under East of Diesel Tank 9-10 3.2 <0.6 41.3 D1W 11/5/2020 Under West of Diesel Tank 9-10 0.2 <0.63 6.9 D2-W 11/5/2020 Under West of Diesel Tank 9-10 0.7 <0.57 5.7 D2-E 11/5/2020 Under East of Diesel Tank 9-10 1.0 6.3 6.1 DLS1 11/5/2020 Diesel Product Line Sample 2-2.5 1.0 <0.7 8 DLS2 11/5/2020 Diesel Product Line Sample 2-2.5 0.2 <0.86 12.5 DLS3 11/5/2020 Diesel Product Line Sample 2-2.5 0.2 <0.69 18.3 KT-W 11/6/2020 Under Kerosene Tank 8-9 0.0 <0.7 4.4 KT-E 11/6/2020 Under Kerosene Tank 8-9 0.0 <0.76 6.1 KD1 11/5/2020 Kerosene Dispenser 1.5-2 0.3 2.3 6.4 KLS1 11/5/2020 Kerosene Product Line Sanoke 2-2.5 0.2 <0.62 2.1 FID= flame-ionizaton detector GRO= Gasoline Range Organics TPH= Total Petroleum PPM= parts-per-million DRO= Diesel Range Organics Hydrocarbons (GRO + DR PID= Photoionization Detector mg/kg= milligrams-per-kilogram NA= Not Applicable HC= Hydrocardons "------" = No Laboratory Analysis PHC= Petroleum Hydrocarbons * Bold values indicate concentrations above NCDEQ initial action levels 100NC Initial Action Level - UST Section for 505035/5030-GRO; 3550-DRO TABLE 3 Summary of UST Closure Soil Sample Results For Diesel & Kerosene USTs Former C & H Shell - Colvard Oil Company Offices 317 S. Jefferson Ave. West Jefferson, Ashe County, North Carolina Analytical Analytical Parameter Method CESW CWSW CBS CNWSW CSSW 3KGW Soil to Residential Sample Date:11/4/2020 11/4/2020 11/4/2020 11/4/2020 11/4/2020 11/6/2020 Groundwater MSCC MSCC Sample Depth (feet):8-9 9-10 10-11 7-8 8-9 8-9 (3K Gas UST)(mg/kg)(mg/kg) C5-C8 Aliphatics (x)VPH ND 23.7 216 235 407 ND 72 939 C9-C12 Aliphatics (a)VPH ND 35.6 109 82.4 494 11.6 C9-C18 Aliphatics (b)EPH NA NA NA NA NA NA 3300 9386 C9-C18 Aliphatics (a-c)+b VPH/EPH ND 35.6 109 82.4 494 11.6 C19-C36 Aliphatics (y)EPH NA NA NA NA NA NA CI 93860 C9-C10 Aromatics (c)VPH ND 20.7 66 55.7 192 13.4 C11-C22 Aromatics (d)EPH NA NA NA NA NA NA 34 469 C9-C22 Aromatics (c+d)VPH/EPH ND ND 66 55.7 192 13.4 EPA Method 8260 Acetone 8260 ND ND ND ND ND ND 24 14,000 Benzene 8260 0.0941 0.479 0.182 ND 5.91 ND 0.0056 18 n-Butylbenzene 8260 1.18 ND 2.56 1.34 3.4 0.351 4.3 626 sec-Butylbenzene 8260 ND ND 0.76 1.01 ND 0.0535 3.3 626 tert-Butylbenzene 8260 ND ND ND 0.0251 ND ND 3.4 626 Chlorobenzene 8260 ND ND ND 0.0332 0.037 ND 0.44 312 1,2-Dichloroethane 8260 ND ND ND ND 0.0826 ND 0.0019 7 Ethylbenzene 8260 4.03 3.43 3.56 0.173 28.2 ND 4.9 1,560 IPE 8260 ND ND ND ND 0.494 ND 0.37 156 Isopropylbenzene 8260 0.714 0.292 1.04 1.1 2.75 0.0233 1.7 1,564 p-Isopropyltoluene 8260 ND 0.182 ND ND ND ND 0.12 100 Methylene Chloride 8260 ND ND ND ND ND ND 0.02 85 4-Methyl-2-pentanone (MIBK) 8260 0.601 ND 1.68 2.290 2.0400 ND 0.4 1200 MTBE 8260 ND ND ND ND ND ND 0.091 350 Naphthalene 8260 3.99 1.23 2.79 0.368 14.8 0.846 0.16 313 n-Propylbenzene 8260 3.02 0.932 0.446 3.78 9.63 0.119 1.7 626 Toluene 8260 1.02 0.108 0.0085 ND 4.04 ND 4.3 1,200 1,2,4-Trimethylbenzene 8260 14.3 5.67 5.71 0.22 21.4 ND 8.5 782 1,3,5-Trimethylbenzene 8260 5.08 1.75 1.7 ND 7.89 ND 8.3 782 Total Xylenes 8260 12.5 11.5 5.38 0.347 38.1 ND 4.6 3,129 NA=Not Analzyed for this parameter BOLD values are above Soil-to-Groundwater BOLD, Highlighted are above Industrial MSCCs MSCC=Maximum Soil Contaminant Concentration mg/kg = milligrams/kilograms.BOLD and shaded are above Residential MSCCs PPM = Parts Per Million ND=Not Detected Sample Number 317 S. Jefferson Ave., Ashe County, West Jefferson, NC NCDEQ Incident # Pending TABLE 4 Post-Excavation Risk-Based Analytical Results (Gasoline USTs) Former C & H Shell PID (Tax Number)Owner/Occupant NameOwner Address Owner CityOwner StateOwner ZipProperty Address (West Jefferson, NC 2869319223624230LAWRENCE WILLIAM BRENT & HEIDI C2896 CUPENO COURTJAMULCA91935215 S JEFFERSON AVE19223624218LEEPER SHAWN K & LISA V3978 GARDENWOOD CIRGRANTFL 32949-8245215 S JEFFERSON AVE19223624217BEAMON JAMES R & CAROLINE KPO BOX 1403NORTH WILKESBORO NC28659215 S JEFFERSON AVE19223624216POSEY PHILIP W & CAROL K4759 LIGHTKEEPERS WAY UNIT 14HLITTLE RIVERSC 29566-7988215 S JEFFERSON AVE19223624216POSEY PHILIP W & CAROL K4759 LIGHTKEEPERS WAY UNIT 14HLITTLE RIVERSC 29566-7988215 S JEFFERSON AVE19223624215HARRELL JEFFREY SPO BOX 1374JEFFERSONNC 28640-1374215 S JEFFERSON AVE19223624214HAWKINS PERRY DAVID & JUDY H497 LIBERTY LANDING DRFLEETWOODNC 28626-9836215 S JEFFERSON AVE19223624213BECK MARTHA4 INDIGO RUN DR APT 3921HILTON HEADSC 29926-4145215 S JEFFERSON AVE19223624212LIVINGSTONE KAREN311 TONI AVEBLOWING ROCK NC 28605-9918212 S JEFFERSON AVE19223624211MERRILL FRANK S JR & STANALAND JANET LPO BOX 2016ANGLETONTX 77516-2016211 S JEFFERSON AVE19223624210ALLEN DANIEL WESLEY107 SMALL OAK LNKINGNC 27021-7829210 S JEFFERSON AVE19223624209LANEY MATTHEW & APRILPO BOX 74GLENDALE SPRINGS NC28629209 S JEFFERSON AVE19223624208CAUSBY FIVE PROPERTIES LLC670 STONE RDSALISBURYNC 28146-8927208 S JEFFERSON AVE19223624208CAUSBY FIVE PROPERTIES LLC670 STONE RDSALISBURYNC 28146-8927208 S JEFFERSON AVE19223624207GUPTON ROGER MORE & SMITH ANNA LOUISE215 S JEFFERSON AVE UNIT 207W JEFFERSON NC 28694-7703207 S JEFFERSON AVE19223624206DENNY RICHARD KYLE & CHRISTY GREENE277 DOYLE BARE RDW JEFFERSON NC 28694-9231206 S JEFFERSON AVE19223624204POTEAT JILLPO BOX 1524W JEFFERSON NC 28694-1524204 S JEFFERSON AVE19223624203LEE JAMES & LISAPO BOX 658ANGLETONTX 77516-0658203 S JEFFERSON AVE19223624202WOODS TODD R & LISA A215 S JEFFERSON AVEW JEFFERSON NC 28694-9803202 S JEFFERSON AVE19223624201DENNY LONNIE R & TINA S215 S JEFFERSON AVE UNIT 201W JEFFERSON NC 28694-9804201 S JEFFERSON AVE19223624109POSEY CAROL P & PHILIP W4759 LIGHTKEEPERS WAY UNIT 14HLITTLE RIVERSC 29566-7988109 S JEFFERSON AVE19223624108HARRELL JEFFREY SPO BOX 1374JEFFERSONNC 28640-1374108 S JEFFERSON AVE19223624107BACHMAN ROBERT & ANNEMARIE14514 BAREFOOT LNPARRISHFL 34219-4576107 S JEFFERSON AVE19223624106VELA JAMIE KAY215 S JEFFERSON AVE UNIT 106W JEFFERSON NC 28694-9805106 S JEFFERSON AVE19223624105MILLS JEFFREY KENNETH & DENISE JONES7239 COBBLECREEK DRMATTHEWSNC 28104-8641105 S JEFFERSON AVE19223624104JOHNSON KENNETH MILES & JOYCE MELISSA JO437 FOUR BROOKS RDWINSTON SALEM NC 27107-9656104 S JEFFERSON AVE19223624103DEAL JR WILLARD MCCREEPO BOX 1907W JEFFERSON NC 28694-1907103 S JEFFERSON AVE19223624102TREADWAY ROBERT SAMUEL JR & TERESA GAMBLE7480 LEXFORD CTCONCORDNC 28025-1209102 S JEFFERSON AVE19223624101THOMAS BEVERLY SWANN & HARRELL JEFFREY S215 S JEFFERSON AVE UNIT 101W JEFFERSON NC 28694-9805101 S JEFFERSON AVE19223001975 BROUGHAM LLC FLORIDA LIMITED LIABILITY COMPANY225 HICE AVEW JEFFERSON NC 28694-7059207 S JEFFERSON AVE19223001975 BROUGHAM LLC FLORIDA LIMITED LIABILITY COMPANY225 HICE AVEW JEFFERSON NC 28694-7059207 S JEFFERSON AVE19223001974JIMMY AND JEANS820 RANDY BYLAND RDFLEETWOODNC 28626-925259719223001974JIMMY AND JEANS821 RANDY BYLAND RDFLEETWOODNC 28626-925359719223001971WJ CAPITAL LLC9164 NC HIGHWAY 88 ELAUREL SPGSNC 28644-8634603 S JEFFERSON AVE19223001969MABRO PROPERTIES LLC420 NORTHWOOD DRRALEIGHNC27609 19223001968MABRO PROPERTIES LLC420 NORTHWOOD DRRALEIGHNC27609 19223001967ASHE COUNTY CHEESE LLCPO BOX 447WEST JEFFERSON NC28694200 E MAIN ST19223001965FOWLER ROBERT L101 GLENN DRW JEFFERSON NC 28694-7545 19223001954LAND PATRICK IAN & KATHERINE A3229 COLONY RDCHARLOTTENC28211 19223001941PARKER TIE COMPANY INCPO BOX 65WEST JEFFERSON NC 28694-0065200 E MAIN ST19223001939DRANE HENRY M & KRISTINA J405 CALVIN AVEWEST JEFFERSON NC28694405 CALVIN AVE19223001938SABLET WEST LLCPO BOX 1503WEST JEFFERSON NC2869412 S JEFFERSON AVE19223001937VANNOY JAMES MARKPO BOX 635JEFFERSONNC 28640-0635215 S JEFFERSON AVE19223001923COLVARD RENA EMILY ET AL1230 PADDOCK CIRCHARLOTTENC 28209-2442 19223001914LOPEZ J REYES BARCENAS & GRACIELA AGUILAR BARCENASPO BOX 1016WEST JEFFERSON NC28694 19223001913BALL BETTY JANE103 E BUCK MOUNTAIN RDW JEFFERSON NC 28694-7374 19223001912MILLER DARRELL KEITHPO BOX 81WEST JEFFERSON NC 28694-0081 19223001911LITTLE RANDALL & KATRINA MILLER C/O KINA JONES167 OAK GROVE CICLEJEFFERSONNC28640 19223001907PARKER TIE COMPANY INCPO BOX 65WEST JEFFERSON NC 28694-0065215 S JEFFERSON AVE19223001906COBBLE CREEK HOLDINGS LLCPO BOX 1848W JEFFERSON NC 28694-1848230 HICE AVE19223001906COBBLE CREEK HOLDINGS LLCPO BOX 1848W JEFFERSON NC 28694-1848230 HICE AVE19223001905COBBLE CREEK HOLDINGS LLCPO BOX 1848W JEFFERSON NC 28694-1848230 HICE AVE19223001903DRANE HENRY M & KRISTINA J405 CALVIN AVEWEST JEFFERSON NC28694201 LONG STTABLE 5Surrounding Properties Within 1,000' of Source AreaColvard Oil - C&H Shell317 S. Jefferson Ave., West Jefferson, NC PID (Tax Number)Owner/Occupant NameOwner Address Owner CityOwner StateOwner ZipProperty Address (West Jefferson, NC 2869319223001899HARE STEVEN LPO BOX 493HAYSNC28635508 GRAYBEAL AVE19223001898BLUE OCEAN VIEW LLC2615 OLD MORGANTON RDLENOIRNC 28645-9687 19223001853PARSONS DONALD J JRPO BOX 389WEST JEFFERSON NC28694202 BACKSTREET19223001833HART MYRON K & LINDY L355 BALDWIN RDWEST JEFFERSON NC 28694-9160302 BACKSTREET19223001827COMMUNITY APARTMENTS CORPORATION OF1331 SUNDAY DRRALEIGHNC27607113 BURKETT AVE19223001825BARNETT CHARLES LEE WALL228 YELTON COURTNASHVILLETN 37211-3425105 DYKE ST19223001823POLLARD DUANE1097 WILLIE BROWN RDCRUMPLERNC 28617-9373 19223001819GRIFFITH WILLIAM ANDREW & RHONDA109 BURKETT AVEWEST JEFFERSON NC28694109 BURKETT AVE19223001817KINGSWOOD INVESTMENTS LLC875 MOUNT JEFFERSON RD STE 1W JEFFERSON NC 28694-8579 16 E BUCK MOUNTAIN RD19223001779LITTLE RANDAL A & KATRINA MILLERPO BOX 147WEST JEFFERSON NC28694203 E BUCK MOUNTAIN RD19223001778BROOKS J DAVID (L/E)533 SAWYERS RDWARRENSVILLE NC 28693-9274306 BACKSTREET19223001777NWO LLC2014 DARTMOUTH PLACECHARLOTTENC28207204 S JEFFERSON AVE19223001754DJS ASSOCIATES LLCPO BOX 569BOONENC 28607-0569102 LONG ST19223001750WARNER SHIRLEY ANNE2531 WEST MILLER CREEK RDWARRENSVILLE NC28693 19223001688MCGUNEGLE JULIE104 E BUCK MOUNTAIN RDW JEFFERSON NC 28694-7374 104 E BUCK MOUNTAIN RD19223001687WILLIAMS JAMES T106 E BUCK MOUNTAIN RDWEST JEFFERSON NC28694106 E BUCK MOUNTAIN RD19223001686EDWARDS JONATHAN & KARA108 E BUCK MOUNTAIN RDW JEFFERSON NC 28694-7374 108 E BUCK MOUNTAIN RD19223001685BEAVER WILLIAM B914 COCHRAN DRLAKE WORTHFL 33461-5711 110 E BUCK MOUNTAIN RD19223001667ASHE COUNTY BOARD OF EDUCATIONPO BOX 604JEFFERSONNC 28640-0604414 SCHOOL AVE19223001662RUSSELL ELIZABETH T101 GLENN DRW JEFFERSON NC 28694-7545101 GLENN DR19223001661MULLIS LINDA103 GLENN DRWEST JEFFERSON NC28694103 GLENN DR19223001660FURR JAMES H & AUDREY W (TRUSTEES)4165 WRANGLER DR SWCONCORDNC 28027-3966 19223001658FOX JEANNIE M (1/2 UNDIVIDED INTEREST)1083 MULATTO MOUNTAIN RDW JEFFERSON NC 28694-8157102 WITT DR19223001648BARNETT CHARLES LEE W228 YELTON CTNASHVILLETN 37211-3425 19223001647BARNETT CHARLES LEE WALL228 YELTON COURTNASHVILLETN 37211-3425 19223001646HOWELL JOSHUA LEE & TIFFANY S103 BURKETT AVEWEST JEFFERSON NC28694103 BURKETT AVE19223001645CARLTON II JEFFERY STEVEN107 BURKETT AVEW JEFFERSON NC 28694-9502107 BURKETT AVE19223001644ESTRADA LUCIO R & LAURA111 BURKETT AVEWEST JEFFERSON NC 28694-9502111 BURKETT AVE19223001643BARNETT CHARLES LEE WALL228 YELTON COURTNASHVILLETN 37211-3425 19223001642POLLARD DUANE1097 WILLIE BROWN RDCRUMPLERNC 28617-9373211 BURKETT AVE19223001641BLACK BEVERLY J192 SUMMER STJEFFERSONNC28640301 BURKETT AVE19223001640MYERS ROMAN BRADSHAW301 COLLEGE AVEW JEFFERSON NC 28694-9115303 BURKETT AVE19223001639BARNETT CHARLES LEE W228 YELTON CTNASHVILLETN 37211-3425 19223001638AMERICAS #1 INVESTMENT INC2705 BEAVER CREEK SCHOOL RDW JEFFERSON NC28694309 BURKETT AVE19223001637AMERICAS #1 INVESTMENT INC2705 BEAVER CREEK SCHOOL RDW JEFFERSON NC28694 19223001636PLEASANT WILLIAM G & PLEASANT THOMAS W263 HOBBLE CREEK LANEBOONENC28607402 SCHOOL AVE19223001635OSBORNE MARILYN404 SCHOOL AVEW JEFFERSON NC 28694-9314404 SCHOOL AVE19223001634ASHE COUNTY BOARD OF EDUCATIONPO BOX 604JEFFERSONNC 28640-0604 19223001633JONES WILLIAM JR & STACY M SOMERS45312 ELMBROOK DRCALIFORNIAMD20619106 BURKETT AVE19223001632YOUNG CHRISTOPHER108 BURKETT AVEWEST JEFFERSON NC28694108 BURKETT AVE19223001631KEMPER JAMES E JR3437 BEECH MINT DRMINT HILLNC28227112 BURKETT AVE19223001630YOW MARY LOU (TRUST)4300 ALICE ST SWSHALLOTTENC 28470-5534114 BURKETT AVE19223001629BOWEN ELSIE M304 BURKETT AVEW JEFFERSON NC 28694-9549304 BURKETT AVE19223001628SAMPLE JOSEPH306 BURKETT AVEWEST JEFFERSON NC28694306 BURKETT AVE19223001627BLEDSOE MISTY LYNN9835 HWY 221 SOUTHFLEETWOODNC28626308 BURKETT AVE19223001626POTTER HOLDINGS INCORPORATED162 ASHE CENTRAL SCHOOL RDJEFFERSONNC 28640-9106492 HAMILTON ST19223001625POTTER HOLDINGS INCORPORATED162 ASHE CENTRAL SCHOOL RDJEFFERSONNC 28640-9106494 HAMILTON ST19223001624JEFFERSON STATION PARTNERS LTD PARTPO BOX 1819GARNERNC 27529-1819215 S JEFFERSON AVE19223001623L.D. DOLLAR IV INCPO BOX 173WEST JEFFERSON NC28694317 S JEFFERSON AVE192230016221GOLDENTREE LLC2200 WHISKERY DRWAXHAWNC 28173-6960401 S JEFFERSON AVE19223001621CENTRAL TELEPHONE CO1025 ELDORADO BLVDBROOMFIELDCO 80021-8254403 S JEFFERSON AVE19223001620WARNER SHIRLEY ANNE2531 WEST MILLER CREEK RDWARRENSVILLE NC28693405 S JEFFERSON AVE19223001617O'ROURKE PATRICK (TRTE)414 HIGH POINT DR STE 1COCOAFL32926503 S JEFFERSON AVE19223001615IGLESIAS MONIQUE & NORDELO CHRISTOPHER J9229 SW 154TH AVEMIAMIFL 33196-1138601 S JEFFERSON AVE19223001614ROSTOB INC191 TRISTATE KNLSPINEY CREEKNC 28663-9284605 S JEFFERSON AVE19223001613E G G INVESTMENTS LLC334 INDIAN LAKE DRWEST JEFFERSON NC 28694-9171607 S JEFFERSON AVE PID (Tax Number)Owner/Occupant NameOwner Address Owner CityOwner StateOwner ZipProperty Address (West Jefferson, NC 2869319223001612BLACKWELDER PHILIP ANDREW & CHRISTINE DIANA2131 LANIER AVECHARLOTTENC28205600 SPRUCE ST19223001597DAVIS HOBART G402 N CHURCH AVEW JEFFERSON NC28694 19223001597DAVIS HOBART G402 N CHURCH AVEW JEFFERSON NC28694 19223001596MILLER DARRELL KEITHPO BOX 81WEST JEFFERSON NC 28694-0081 105 E BUCK MOUNTAIN RD19223001595BALL BETTY JANE103 E BUCK MOUNTAIN RDW JEFFERSON NC 28694-7374 103 E BUCK MOUNTAIN RD19223001594LOPEZ J REYES BARCENAS & GRACIELA AGUILAR BARCENASPO BOX 1016WEST JEFFERSON NC28694 19223001593SULLIVAN CRAIG JOSEPH716 MOUNT JEFFERSON RDW JEFFERSON NC28694510 GRAYBEAL AVE19223001592WOODIE VADA (HEIRS)PO BOX 39HICKORYNC28603 19223001591BLEVINS MARGARET WOOD121 COUNTRY LANEMILLERS CREEK NC28651506 GRAYBEAL AVE19223001590LLL LLC972 RIVERWIND RDLANSINGNC 28643-8758 101 E BUCK MOUNTAIN RD19223001589KCG PROPERTIES LLCPO BOX 1235JEFFERSONNC28640102 E BUCK MOUNTAIN RD19223001588KCG PROPERTIES LLCPO BOX 1235JEFFERSONNC28640408 GRAYBEAL AVE19223001587CARTER TIMOTHY D OR ROBIN J (TRUSTEES)117 OAKVIEW DRJEFFERSONNC 28640-9410405 GRAYBEAL AVE19223001586DOLLAR JAMES A & CAROLYN J (L/E)404 GRAYBEAL AVEWEST JEFFERSON NC 28694-9730404 GRAYBEAL AVE19223001585GOSSETT NORMAN E SR (HEIRS)103 LONG STW JEFFERSON NC 28694-9709103 LONG ST19223001584ROBINSON DEBORAH ANN & MORROW JR603 MEADOW LANE AVEW JEFFERSON NC 28694-9792402 GRAYBEAL AVE19223001583GREENE CALVINPO BOX 270WEST JEFFERSON NC28694105 LONG ST19223001582JOYCE SARAH S107 LONG STWEST JEFFERSON NC28694107 LONG ST19223001581FUNES INES MATAPO BOX 1420WEST JEFFERSON NC 28694-1420109 LONG ST19223001580ELDRETH LOUIS ALLEN JR501 SOUTH STJEFFERSONNC 28640-8009111 LONG ST19223001579PARSONS DONALD JOE JRPO BOX 389W JEFFERSON NC 28694-0389 19223001578BARNES APRIL202 E BUCK MOUNTAIN RDW JEFFERSON NC 28694-7370 19223001576PARSONS DONALD JOE JRPO BOX 389W JEFFERSON NC 28694-0389 19223001575PARSONS DONALD JOE JRPO BOX 389W JEFFERSON NC 28694-0389 19223001574HART MYRON K & LINDY L355 BALDWIN RDWEST JEFFERSON NC 28694-9160 19223001573BLEVINS MARK127 MACE DOLLAR RDWEST JEFFERSON NC28694106 LONG ST19223001572PHIPPS CONSTRUCTION LLC425 COLONEL FRANCIS RDCRUMPLERNC28617104 LONG ST19223001571SABLET WEST LLCPO BOX 1503WEST JEFFERSON NC28694412 BACKSTREET19223001570C PHIPPS PROPERTIES LP422 E 2ND ST UNIT 1W JEFFERSON NC2869419006019223001569FIFTH THIRD BANK38 FOUNTAIN SQUARE PLAZA MD 10ATA1CINCINNATIOH45263402 S JEFFERSON AVE19223001568THE WEST JEFFERSON ABC BOARD404 S JEFFERSON AVEWEST JEFFERSON NC28694404 S JEFFERSON AVE19223001567PETERS MARTY & HEATHER (1/2) &PO BOX 830W JEFFERSON NC 28694-0830 19223001566P & R INVESTMENTSPO BOX 830W JEFFERSON NC2869419005619223001563P AND R INVESTMENTSPO BOX 830WEST JEFFERSON NC2869417 E BUCK MOUNTAIN RD19223001562MOUNTAIN ADVANTAGE LLCPO BOX 830W JEFFERSON NC 28694-0830502 S JEFFERSON AVE19223001560LEASHOMB STEVEN JAMES SR & ANNETTE641 OAKWOOD RDWEST JEFFERSON NC2869449 SHORT ST19223001559CALLANAN ANDREW A; & POPE NATALIE C2612 CLERESTORY PLRALEIGHNC 27615-8404603 GRAYBEAL AVE19223001558LOPEZ J REYES BARCENAS209 APPALOOSA LNFLEETWOODNC 28626-9152605 GRAYBEAL AVE19223001556L.D. DOLLAR III INCPO BOX 173WEST JEFFERSON NC28694602 S JEFFERSON AVE19223001555GOSAI ARVIND & USHA4327 BERRY BEND LANERICHMONDTX77406604 S JEFFERSON AVE19223001554LEVITON MANUFACTURING CO INC201 N SERVICE RDMELVILLENY 11747-3138618 S JEFFERSON AVE19223001291PARKWAY STORAGE LLCPO BOX 3CRUMPLERNC286175 W ASHE ST19223001290PARKWAY STORAGE LLCPO BOX 3CRUMPLERNC286175 W ASHE ST19223001288HART MYRON K & LINDY L355 BALDWIN RDWEST JEFFERSON NC 28694-9160W ASHE STREET19223001286AF BANKPO BOX 26WEST JEFFERSON NC 28694-00268 W ASHE ST19223001285TOWN OF WEST JEFFERSONPO BOX 490WEST JEFFERSON NC28694174 BACKSTREET19223001284COUNTY OF ASHE150 GOVERNMENT CIR STE 2500JEFFERSONNC2864019006019223001283LAND PATRICK IAN & KATHERINE A3229 COLONY RDCHARLOTTENC282116 W ASHE ST19223001282TOWN OF WEST JEFFERSONPO BOX 490WEST JEFFERSON NC28694203 S CHURCH AVE19223001281TOWN OF WEST JEFFERSONPO BOX 490WEST JEFFERSON NC28694 19223001280TOWN OF WEST JEFFERSONPO BOX 490WEST JEFFERSON NC28694 19223001223ROTEN APRIL MPO BOX 577WEST JEFFERSON NC28694202 E BUCK MOUNTAIN RD19223001163HOLDEN TODD201 E BUCK MOUNTAIN RDW JEFFERSON NC 28694-7370 201 E BUCK MOUNTAIN RD19223001133PARKER TIE COMPANY INCPO BOX 65WEST JEFFERSON NC 28694-0065 19223001124PARKER TIE COMPANY INCPO BOX 65WEST JEFFERSON NC 28694-006519 S THIRD AVE19223001108RAY RITZ C JR256 HOLLIN WAYWINSTON SALEM NC27104 PID (Tax Number)Owner/Occupant NameOwner Address Owner CityOwner StateOwner ZipProperty Address (West Jefferson, NC 2869319223001107PARKER TIE COMPANY INCPO BOX 65WEST JEFFERSON NC 28694-006519 S THIRD AVE19223001106PARKER TIE COMPANY INCPO BOX 65WEST JEFFERSON NC 28694-0065 19223001105PACK FAN INVESTMENTS LLC362 RIDGE DRWEST JEFFERSON NC 28694-930620 E ASHE ST19223001104NEW RIVER PROPERTIES LLC380 BUCKS LNWARRENSVILLE NC 28693-9597108 S THIRD AVE19223001103BROWN TERRY M211 PLUMSTEAD LNCLEMMONSNC 27012-9643106 S THIRD AVE19223001102ASHE LODGE #594UNKNOWNUNKNOWNNC0104 S THIRD AVE19223001101PARKER TIE COMPANY INCPO BOX 65WEST JEFFERSON NC 28694-0065106 S THIRD AVE19223001100TAGM LLC347 PADDY AVEWEST JEFFERSON NC286943 E STATE ST19223001099TAGM LLC347 PADDY AVEWEST JEFFERSON NC286943 E STATE ST19223001098PARKER TIE COMPANY INCPO BOX 65WEST JEFFERSON NC 28694-006518 S THIRD AVE19223001097PARKWAY THEATER LLC171 GREEN HILL DRWEST JEFFERSON NC2869410 E MAIN ST19223001096MICHAEL D VANNOY ENTERPRISES INCPO BOX 110WEST JEFFERSON NC286948 E MAIN ST19223001073TOWN OF WEST JEFFERSONPO BOX 490WEST JEFFERSON NC286941 S JEFFERSON AVE19223001072GREEN DARREN JPO BOX 270W JEFFERSON NC 28694-02705 S JEFFERSON AVE19223001071MILLER R CRAIG & VIVIAN S302 4TH AVE SKURE BEACHNC284497 S JEFFERSON AVE19223001070MILLER R CRAIG & VIVIAN S302 4TH AVE SKURE BEACHNC284499 S JEFFERSON AVE19223001069TOWN OF WEST JEFFERSONPO BOX 490WEST JEFFERSON NC28694 19223001068JONES DANNY E & ROBIN B147 EAST STJEFFERSONNC28640101 S JEFFERSON AVE19223001067MCNEILL WILLIAM TERRY (TRUSTEE) &527 OAKWOOD RDWEST JEFFERSON NC 28694-8353105 S JEFFERSON AVE19223001066MILLER CHRISTOPHER V &PO BOX 390WEST JEFFERSON NC28694107 S JEFFERSON AVE19223001065AF BANKPO BOX 26WEST JEFFERSON NC 28694-0026111 S JEFFERSON AVE19223001064ASHE FEDERAL SAVINGS & LOAN ASSOC.PO BOX 26WEST JEFFERSON NC28694 19223001063MT JEFFERSON PRESBYTERIAN CHURCHPO BOX 782WEST JEFFERSON NC28694201 S JEFFERSON AVE19223001062MT JEFFERSON PRESBYTERIAN CHURCHPO BOX 782WEST JEFFERSON NC28694203 S JEFFERSON AVE19223001061ASHE FEDERAL SAVINGS & LOAN ASSOC.PO BOX 26WEST JEFFERSON NC28694205 S JEFFERSON AVE19223001060ASHE FEDERAL SAVINGS & LOAN ASSOC.PO BOX 26WEST JEFFERSON NC28694207 S JEFFERSON AVE19223001059BLUE OCEAN VIEW LLC2615 OLD MORGANTON RDLENOIRNC 28645-9687312 S JEFFERSON AVE19223001058BLUE OCEAN VIEW LLC2615 OLD MORGANTON RDLENOIRNC 28645-9687308 S JEFFERSON AVE19223001057RYAN JOHN O JR & MARINAPO BOX 849WEST JEFFERSON NC28694306 S JEFFERSON AVE19223001056RYAN JOHN O JR & MARINAPO BOX 849WEST JEFFERSON NC28694304 S JEFFERSON AVE19223001055GBDB HOLDINGS LLCPO BOX 1619WEST JEFFERSON NC28694302 S JEFFERSON AVE19223001054GRANITE HARDWOODS INCPO BOX 226GRANITE FALLS NC28630214 S JEFFERSON AVE19223001053EASON HEIDI LEE BADIANO475 WES RANDALL RDDEEP GAPNC28618208 S JEFFERSON AVE19223001052ASHE FEDERAL BANKPO BOX 26WEST JEFFERSON NC28694206 S JEFFERSON AVE19223001051ABSHER ENTERPRISES LLC756 NC HWY 88 EJEFFERSONNC28640202 S JEFFERSON AVE19223001050GBDB HOLDINGS LLCPO BOX 1629W JEFFERSON NC28694 19223001049GBDB HOLDINGS LLCPO BOX 1629W JEFFERSON NC28694 19223001048GBDB HOLDINGS LLCPO BOX 1629W JEFFERSON NC28694108 S JEFFERSON AVE19223001047ELLIOTT NORMAN C & ANNA L (L/E)367 GENTRY STJEFFERSONNC28640106 S JEFFERSON AVE19223001046TOWN OF WEST JEFFERSONPO BOX 490WEST JEFFERSON NC28694104 S JEFFERSON AVE19223001045VANNOY WILLIAM B & TRACY E155 CHARTER RDGJEFFERSONNC28640102 S JEFFERSON AVE19223001044WOLFPACKER PROPERTIES LPPO BOX 130JEFFERSONNC2864014 S JEFFERSON AVE19223001043THE PAUL AND FLORENCE THOMASPO BOX 373WEST JEFFERSON NC2869410 S JEFFERSON AVE19223001042THORE JOEY F & TAMMY LUMPO BOX 766JEFFERSONNC286408 S JEFFERSON AVE19223001041MLSJ LLC417 WEAVER FARMS RDW JEFFERSON NC 28694-75296 S JEFFERSON AVE19223001020BRIDGETREE INVESTMENTS LLCPO BOX 69FORT MILLSC 29716-00693 W MAIN ST19223001019BRIDGETREE INVESTMENTS LLCPO BOX 69FORT MILLSC 29716-0069 19223001018PARSONS DONALD J JRPO BOX 389WEST JEFFERSON NC286941 W STATE ST19223001017MOUNTAIN OUTFITTERS LLCPO BOX 265JEFFERSONNC28640201 BACKSTREET19223001016PARSONS DONALD J JRPO BOX 389WEST JEFFERSON NC28694203 BACKSTREET19223001015PARSONS DONALD J JRPO BOX 389WEST JEFFERSON NC28694205 BACKSTREET19223001014PREECE TERRY D & NANCY E1599 SW 15TH STBOCA RATONFL33486207 BACKSTREET19223001013HOLE LOTTA DOUGHNUTS REAL ESTATE LLCPO BOX 153W JEFFERSON NC 28694-0153211 BACKSTREET19223001012GDBD HOLDINGS LLCPO BOX 1629W JEFFERSON NC28694 19223001011GDBD HOLDINGS LLCPO BOX 1629W JEFFERSON NC28694301 BACKSTREET19223001010PARSONS DONALD J JRPO BOX 389WEST JEFFERSON NC28694303 BACKSTREET PID (Tax Number)Owner/Occupant NameOwner Address Owner CityOwner StateOwner ZipProperty Address (West Jefferson, NC 2869319223001008HART MYRON K & LINDY L355 BALDWIN RDWEST JEFFERSON NC 28694-9160305 BACKSTREET19223001007HART MYRON K & LINDY L355 BALDWIN ROADWEST JEFFERSON NC28694305 BACKSTREET19223001006HART MYRON K & LINDY L355 BALDWIN RDWEST JEFFERSON NC 28694-9160401 BACKSTREET19223001005HART MYRON K & LINDY L355 BALDWIN RDWEST JEFFERSON NC 28694-91600 R R AVENUE19223001004SUPREME PETROLEUM TRANSPORT COPO BOX 173WEST JEFFERSON NC28694 19223001003SUPREME PETROLEUM TRANSPORT COPO BOX 173WEST JEFFERSON NC28694403 BACKSTREET19223001002HALE TOD E & DAWNPO BOX 211WEST JEFFERSON NC28694314 S JEFFERSON AVE19223001001BLEVINS MARGARET WOOD (2/3) & ANNA121 COUNTRY LNMILLERS CREEK NC28651 Monitoring Well Well Riser Screen Grout Bentonite Sand Date Well Depth Diameter Interval Interval Interval Interval Interval Constructed (feet) (inches) (feet) (feet) (feet) (feet) (feet) MW-1 15 2 0-5 5-15 0.5-2 2-3 3-15 12/09/22 MW-2 15 2 0-5 5-15 0.5-2 2-3 3-15 12/09/22 MW-3 15 2 0-5 5-15 0.5-2 2-3 3-15 12/09/22 317 S. Jefferson Ave. West Jefferson, NC C&H Shell Monitoring Well Construction Details TABLE 6 AnalyticalAnalyticalParameterMethod MW-1MW-2 MW-3Sample Date:10/12/2022 10/12/2022 10/12/2022Sample Depth (feet):5-6 feet 5-6 feet 5-6 feet(mg/kg)(mg/kg)(mg/kg)MADEP VPHC5-C8 Aliphatics (x)VPHNDNDND6893924,528C9-C12 Aliphatics (a)VPHNDNDNDC9-C18 Aliphatics (b)EPHNANANDC9-C18 Aliphatics (a-c)+bSumNANANDC19-C36 Aliphatics (y)EPHNANANDCI31,000810,000C9-C10 Aromatics (c)VPHNDNDNDC11-C22 Aromatics (d)EPHNANANDC9-C22 Aromatics (c+d)SumNANANDEPA Method 8260Acetone8260NDNDND2414,000210,000Benzene82600.01630.0191ND0.00721259.4n-Butylbenzene82600.0214NDND2.478211,600sec-Butylbenzene8260ND0.0077ND2.21,56023,300tert-Butylbenzene8260NDNDND1.71,56023,300Chlorobenzene8260NDNDND0.443124,670Chloroform8260NDND0.02740.3720180Ethylbenzene8260ND0.0244ND860.3297IPE8260ND0.0087ND0.32NA2,330Isopropylbenzene8260ND0.0189ND1.31,56023,300p-Isopropyltoluene8260ND0.019ND0.121,56023,300Methylene Chloride8260NDNDND0.0293.81,4004-Methyl-2-pentanone (MIBK)8260NDNDND0.42125018,600MTBE82600.01960.0083ND0.0851561,810Naphthalene8260NDNDND0.2627n-Propylbenzene8260ND0.0192ND1.41,56023,300Tetrachloroethane8260NDND0.03480.00420200Toluene8260ND0.020.0785.41,25018,6001,2,4-Trimethylbenzene82600.1890.02630.00966.61562,3301,3,5-Trimethylbenzene82600.09310.0291ND6.61562,330Total Xylenes82600.1541.10.020963,12046,700NA = Not Analzyed for this parameterBOLD values exceed the Soil-to-Groundwater MSCCsmg/kg = milligrams/kilogram BOLD and shaded values exceed Residential & Commercial/Industrial MSCCs 3146912,264Soil to Groundwater MSCCResidential MSCCCommercial / Industrial MSCC5401,50040,000Sample Number317 S. Jefferson Avenue, West Jefferson, NC 28675TABLE 7 Risk-Based Soil Analytical Results for Soil SamplesColvard Oil Company - C&H ShellNCDEQ Incident # PendingPyramid Project #2021-080 Top of Depth to Depth Free- Free- Corrected CorrectedWell Date Casing Free-To Product Product Depth To WaterNumber Gauged Elevation Product Water Thickness Adjustment Water Elevation (feet) (feet) (feet) (feet) (feet) (feet) (feet)10/13/22 99.89 None 7.71N/AN/AN/A 92.18MW-110/13/22 100.00 None 7.36N/AN/AN/A 92.64MW-210/13/22 98.82 None 7.36N/AN/AN/A 91.46MW-3NG = Not gauged NM = Not measured N/A= Not Applicable317 S. Jefferson Ave., West Jefferson, NC DEQ Incident # 47427Table 8Depth to Groundwater and Groundwater Elevation DataFormer C&H Shell - Current Colvard Oil Offices Page 1 of 1 NCAC 2L GCLsMW-1 MW-2 MW-3Groundwater GroundwaterStandard (ug/L) (ug/L)Volatiles by 6200B10-13-2211.9ND ND10-13-22 0.51 ND ND10-13-22 2.9 ND ND10-13-22 2.83 ND ND10-13-22 18.14 ND ND10-13-22 4.3 ND ND10-13-22 7.6 ND ND10-13-22 ND ND ND10-13-22 ND 1.1 1.610-13-22 ND ND ND10-13-22 ND ND ND10-13-22 0.88 ND ND10-13-22 ND ND ND10-13-22 23.6 ND ND10-13-2238.6ND ND10-13-22 ND ND ND10-13-2251.2ND NDIsopropylbenzeneNaphthaleneStyreneEDB1,2-DichlorobenzeneBenzeneTolueneEthylbenzeneTotal XylenesTOTAL BTEX1,3-Dichlorobenzene1,2,4-TrimethylbenzeneUNITS DATEMONITORING WELL IDTABLE 9Colvard Oil Company - C&H Shell Pyramid Project #2021-080Monitoring Well Groundwater Analytical ResultsMTBEIPE500 85,500600 84,5005,0001ug/lug/lug/lug/lug/lug/lug/lug/lug/lug/lug/lug/lug/l2500070400 2500070 700006 600070 30000285000.005 2000.40 20ug/lNo Standard No Standard0.02 5070 70,00020 20,000317 S. Jefferson Avenue, West Jefferson, NC 286751,3,5-TrimethylbenzeneChloromethaneug/l0.4020600260,000ug/ln-Butylbenzeneug/l400NA = Not analyzed for this parameterND = Not detected NI = Not installed (well installed after this date)NS = Not SampledBold = Exceeds 2L StandardsBold and shaded = Exceeds GCLsPage 1 of 3 NCAC 2L GCLsMW-1 MW-2 MW-3Groundwater GroundwaterStandard (ug/L) (ug/L)UNITS DATEMONITORING WELL IDTABLE 9Colvard Oil Company - C&H Shell Pyramid Project #2021-080Monitoring Well Groundwater Analytical Results317 S. Jefferson Avenue, West Jefferson, NC 2867510-13-2295.1ND ND10-13-22 ND ND ND10-13-22 ND ND ND10-13-22 ND ND ND10-13-22 ND ND ND10-13-22 22.3 ND ND10-13-22 0.6 ND NDEPA 504.110-13-22 ND ND NA10-13-22 ND ND NA10-13-22 ND ND NDMADEP EPH10-13-22 NA NA ND10-13-22 NA NA ND10-13-22 NA NA ND6010 - Metals10-13-22 ND ND ND1,2,3-Tichloropropane1,2-Dibromo-3-chloropropane1,2-Dibromoethane (EDB)Lead (3030C)n-Propylbenzene1,2-DichloroethaneMethylene ChlorideC11-C22 AliphaticsC9-C18 AliphaticsC19-C36 Aliphaticssec-Butylbenzeneug/lug/l660007030000TrichloroetheneTetrachloroethenetert-Butylbenzeneug/lug/lug/l0.770033000701500055000No StandardNo StandardNo Standardug/l15000ug/lug/lug/l0.0050.040.0215ug/lug/l200 No Standardug/l700ug/l708500No Standardug/l10000 No StandardNA = Not analyzed for this parameterND = Not detected NI = Not installed (well installed after this date)NS = Not SampledBold = Exceeds 2L StandardsBold and shaded = Exceeds GCLsPage 2 of 3 NCAC 2L GCLsMW-1 MW-2 MW-3Groundwater GroundwaterStandard (ug/L) (ug/L)UNITS DATEMONITORING WELL IDTABLE 9Colvard Oil Company - C&H Shell Pyramid Project #2021-080Monitoring Well Groundwater Analytical Results317 S. Jefferson Avenue, West Jefferson, NC 28675EPA 625.110-13-22 NA NA 5.6J10-13-22 NA NA 6.2J10-13-22 NA NA 5.6JNA = Not AnalyzedND = Not DetectedNI = Not Installed11.201:Benzenesulfonaug/l400 No Standard15.149:Eicosaneug/l4200 No Standard6.326:Unknownug/l210 No StandardNA = Not analyzed for this parameterND = Not detected NI = Not installed (well installed after this date)NS = Not SampledBold = Exceeds 2L StandardsBold and shaded = Exceeds GCLsPage 3 of 3                             APPENDIX   A                                                        August 25, 2021 Colvard Oil Company, Inc. Mr. Bill Crothers P.O. Box 7 West Jefferson, NC 28694-0007 Re: Notice of Regulatory Requirements 15A NCAC 2L .0405 Risk-based Assessment and Corrective Action for Petroleum Underground Storage Tanks C & H Shell 317 S. Jefferson Avenue West Jefferson, Ashe County Incident number:47247 Risk Classification: Pending Ranking: Pending Dear Mr. Crothers The Initial Abatement Action Report received by the UST Section, Division of Waste Management, Winston-Salem Regional Office on December 12, 2021 has been reviewed. The report indicates that soil contamination exceeds the soil-to-groundwater MSCCs established in Title 15A NCAC 2L .0411. Therefore, the UST Section hereby confirms that you must comply with assessment and reporting requirements of Title 15A NCAC 2L .0405, within the timeframes specified in the attached rule. The requirements of Title 15A NCAC 2L .0405 include the preparation and submittal of a Limited Site Assessment (LSA) Report, in accordance with the rule and the most recent version of the UST Section Assessment Guidelines, within 120 days of discovery of the release. Because a release or discharge has been confirmed, a Licensed Geologist or a Professional Engineer, certified by the State of North Carolina, is required to prepare and certify all reports submitted to the Department of Environmental Quality in accordance with Title 15A NCAC 2L .0103(e) and 2L .0111(b). Please note that before you sell, transfer, or request a “No Further Action” determination for a property that has not been remediated to below “unrestricted use” standards, you must file a Notice of Residual Petroleum ("Notice") with the Register of Deeds in the county where the property is located (NCGS 143B-279.9 and 143B-279.11). Failure to comply with the State's rules in the manner and time specified may result in the assessment of civil penalties and/or the use of other enforcement mechanisms. If you have any questions regarding trust fund eligibility or reimbursement from the Commercial Leaking Petroleum Underground Storage Tank Cleanup Funds, please contact the UST Section Trust Fund Branch Page 2 of 2 at (919) 707-8171. If you have any questions regarding the actions that must be taken or the rules mentioned in this letter, please contact Karen J. Hall at the address listed below. Sincerely, Karen J. Hall Environmental Sr. Specialist Winston-Salem Regional Office UST Section, Division of Waste Management, NCDEQ Enclosures: Title 15A NCAC 2L .0405 A Brief History of North Carolina Session Laws, Rules, and General Statutes… cc: Ashe County Health Department via email Mike Jones and Tim Leatherman, Pyramid Environmental, via email                                 APPENDIX   B                                    Comprehensive Site Assessment Report _________________________________________________________________________________________________ LSA – PYRAMID ENVIRONMENTAL & ENGINEERING, P.C. Limited Site Assessment Risk Classification and Land Use Form Part I – Groundwater/Surface Water/Vapor Impacts High Risk 1. Has the discharge or release contaminated any water supply well including any used for non-drinking purposes? YES/NO If yes, explain. 2. Is a water supply well used for drinking water located within 1000 feet of the source area of the discharge or release? YES/NO 3. Is a water supply well used for any purpose (e.g., irrigation, washing cars, industrial cooling water, filling swimming pools) located within 250 feet of the source area of the release or discharge?YES/NO 4. Does groundwater within 500 feet of the source area of the discharge or release have the potential for future use in that there is no other source of water supply other than the groundwater?YES/NO Explain. 5. Do vapors from the discharge or release pose a threat of explosion because of accumulation of the vapors in a confined space or pose any other serious threat to public health, public safety or the environment? YES/NOIf yes, explain. 6. Are there any other factors that would cause the discharge or release to pose an imminent danger to public health, public safety, or the environment? YES/NO If yes, explain. The Town of West Jefferson supplies drinking water from several municiapal water supply wells. The closest well is located 950 feet side-gradient from the site. NO Wells Within 250 feet. C&HShell Comprehensive Site Assessment Report _________________________________________________________________________________________________ LSA – PYRAMID ENVIRONMENTAL & ENGINEERING, P.C. Intermediate Risk 7. Is a surface water body located within 500 feet of the source area of the discharge or release? YES/NO If yes, does the maximum groundwater contaminant concentration exceed the surface water quality standards and criteria found in 15A NCAC 2B .0200 by a factor of 10? YES/NO 8. Is the source area of the discharge or release located within a designated wellhead protection area as defined in 42 USC 300h-7(e)? YES/NOIf yes, explain. 9. Is the discharge or release located in the Coastal Plain physiographic region as designated on a map entitled “Geology of North Carolina” published by the Department in 1985? YES/NO If yes, is the source area of the discharge or release located in an area in which there is recharge to an unconfined or semi-confined deeper aquifer that is being used or may be used as a source of drinking water?YES/NOIf yes, explain. 10. Do the levels of groundwater contamination for any contaminant exceed the gross contamination levels established (see Table 7) by the Department. YES/NO There is a stream on site that is contained in a box culvert that flows beneath the site. This stream is within 500 feet. Yes, the benzene concentration in MW-1 was 11.9 ug/L. The former USTs were located within the designated wellhead protection area. C&HShell Comprehensive Site Assessment Report _________________________________________________________________________________________________ LSA – PYRAMID ENVIRONMENTAL & ENGINEERING, P.C. Part II - Land Use Property Containing Source Area of Discharge or Release The questions below pertain to the property containing the source area of the release. 1. Does the property contain one or more primary or secondary residences (permanent or temporary)? YES/NOExplain. 2. Does the property contain a school, daycare center, hospital, playground, park, recreation area, church, nursing home, or other place of public assembly? YES/NOExplain. 3. Does the property contain a commercial (e.g., retail, warehouse, office/business space, etc.) or industrial (e.g., manufacturing, utilities, industrial research and development, chemical/petroleum bulk storage, etc.) enterprise, an inactive commercial or industrial enterprise, or is the land undeveloped? YES/NO Explain. 4. Do children visit the property? YES/NO Explain. 5. Is access to the property reliably restricted consistent with its use (e.g., by fences, security personnel or both)? YES/NO Explain. 6. Do pavement, buildings, or other structures cap the contaminated soil? YES/NOExplain. If yes, what mechanisms are in place or can be put into place to ensure that the contaminated soil will remain capped in the foreseeable future? The building is the office for Colvard Oil Co. It is available for children to visit the property, but not regularly. The property is not fenced but it is paved. Any remaining contaminated soil is capped with pavement. The site is in downtown West Jefferson and will be used for commercial purposes. C&HShell Comprehensive Site Assessment Report _________________________________________________________________________________________________ LSA – PYRAMID ENVIRONMENTAL & ENGINEERING, P.C. 7. What is the zoning status of the property? 8. Is the use of the property likely to change in the next 20 years? YES/NOExplain. Property Surrounding Source Area of Discharge or Release The questions below pertain to the area within 1500 feet of the source area of the discharge or release (excludes property containing source area of the release): 9. What is the distance from the source area of the release to the nearest primary or secondary residence (permanent or temporary)? 10. What is the distance from the source area of the release to the nearest school, daycare center, hospital, playground, park, recreation area, church, nursing home or other place of public assembly? 11. What is the zoning status of properties in the surrounding area? 12. Briefly characterize the use and activities of the land in the surrounding area. The property is zoned "HC" for Highway Commercial land use. The Site is in downtown West Jefferson & will remain commercial for at least 20 years. There is a house at 430 feet to the east southeast of the former UST area - Side-gradient. Hometown Diner, a restaurant is located approximately 110 feet from the source area. The properies in the surrounding area are zoned for Community Shopping (C-S), Highway Commercial (H-C) Industrial (M-1 & M-1-C), and Medium Density Residential (R-7). The surrounding area is primarily used for commercial and light industrial purposes. C&HShell                         APPENDIX   C          Pyramid Environmental & Engineering, P.C. FIELD DRILLING RECORD PROJECT NAME: PROJECT NUMBER: BORING/WELL NO: SITE LOCATION: BORING/WELL LOCATION: START DATE: COMPLETED: GEOLOGIST:DRILLER: DRILL METHOD: SAMPLE METHOD: BORING DIA: CASING DIA: TOTAL DEPTH: CASING DEPTH: DEPTH (ft.) VISUAL MANUAL SOIL CLASSIFICATION COLOR, TEXTURE, STRUCTURE, CONSISTENCY, ODOR, ETC. OVA RESULTS PERCENT RECOVERY BLOW COUNTS MONITORING WELL INFORMATION (IF APPLICABLE) RISER LENGTH (ft) DEPTH (ft) DIAMETER (in) MATERIAL .SCREEN LENGTH (ft) DEPTH (ft) DIAMETER (in) MATERIAL .DEPTH TO TOP OF SAND BAGS OF SAND . DEPTH TO TOP SEAL BENTONITE USED BAGS OF CEMENT USED . C&H Shell 2021-080 MW-1 317 S. Jefferson Avenue West Jefferson, NC East of Former Pump Island 10/12/2022 10/12/2022 Tim Leatherman Ransier Environmental Drilling, Inc. (REDI) Auger Grab 6" 2" 15' N/A 0-5'PVC 10-15'PVC 3' 2' .5 Brown clayey sandy silt(ML)with rocks, Most to very moist, petroleum odor Dark brown to black silty, clayey, sand(SC), very moist to saturated, Boring terminated @16 feet, set well at 15 feet with 10 feet of screen. petroleum odor 0-6' 6-16 12.2 ppm 5' 5' 2" 2" 3 .5 Pyramid Environmental & Engineering, P.C. FIELD DRILLING RECORD PROJECT NAME: PROJECT NUMBER: BORING/WELL NO: SITE LOCATION: BORING/WELL LOCATION: START DATE: COMPLETED: GEOLOGIST:DRILLER: DRILL METHOD: SAMPLE METHOD: BORING DIA: CASING DIA: TOTAL DEPTH: CASING DEPTH: DEPTH (ft.) VISUAL MANUAL SOIL CLASSIFICATION COLOR, TEXTURE, STRUCTURE, CONSISTENCY, ODOR, ETC. OVA RESULTS PERCENT RECOVERY BLOW COUNTS MONITORING WELL INFORMATION (IF APPLICABLE) RISER LENGTH (ft) DEPTH (ft) DIAMETER (in) MATERIAL .SCREEN LENGTH (ft) DEPTH (ft) DIAMETER (in) MATERIAL .DEPTH TO TOP OF SAND BAGS OF SAND . DEPTH TO TOP SEAL BENTONITE USED BAGS OF CEMENT USED . C&H Shell 2021-080 MW-2 317 S. Jefferson Avenue West Jefferson, NC South of Former Pump Island 10/12/2022 10/12/2022 Tim Leatherman Ransier Environmental Drilling, Inc. (REDI) Auger Grab 6" 2" 15' N/A 0-5'PVC 10-15'PVC 3' 2' .5 Brown clayey sandy silt(ML), Most to very moist, no petroleum odor Dark brown to gray natural organic rich soil, clayey sandy silt(ML), most Brown silty clayey sand (SC), very moist to saturated, no petroleum odor Boring terminated @ 15 feet, set well at 15 feet with 10 feet of screen to very moist, no petroleum odor 8' - 15' 0-6' 6' - 8' 1.8 ppm 5' 10' 2" 2" 3 .5 Pyramid Environmental & Engineering, P.C. FIELD DRILLING RECORD PROJECT NAME: PROJECT NUMBER: BORING/WELL NO: SITE LOCATION: BORING/WELL LOCATION: START DATE: COMPLETED: GEOLOGIST:DRILLER: DRILL METHOD: SAMPLE METHOD: BORING DIA: CASING DIA: TOTAL DEPTH: CASING DEPTH: DEPTH (ft.) VISUAL MANUAL SOIL CLASSIFICATION COLOR, TEXTURE, STRUCTURE, CONSISTENCY, ODOR, ETC. OVA RESULTS PERCENT RECOVERY BLOW COUNTS MONITORING WELL INFORMATION (IF APPLICABLE) RISER LENGTH (ft) DEPTH (ft) DIAMETER (in) MATERIAL .SCREEN LENGTH (ft) DEPTH (ft) DIAMETER (in) MATERIAL .DEPTH TO TOP OF SAND BAGS OF SAND . DEPTH TO TOP SEAL BENTONITE USED BAGS OF CEMENT USED . C&H Shell 2021-080 MW-3 317 S. Jefferson Avenue West Jefferson, NC North of Colvard Office 10/12/2022 10/12/2022 Tim Leatherman Ransier Environmental Drilling, Inc. (REDI) Auger Grab 6" 2" 15' N/A 0-5'PVC 10-15'PVC 3' 2' .5 Brown to dark brown sandy clayey silt(ML), most, no petroleum odor, rocks or boulders present Brown sandy clayey silt(ML), most to very moist, no petroleum odor Brown silty sandy, clay(CL), very moist to saturated, no petroleum odor Boring terminated @ 15 feet, set well at 15 feet with 10 feet of screen 7' - 15' 0-5' 5' - 7' 5' 10' 2" 2" 3 .5 WELL CONSTRUCTION RECORD This form can be used for single or multiple wells Form GW-1 North Carolina Department of Environment and Natural Resources – Division of Water 5HVRXUFHV Revised AXJXVW 2013 1. Well Contractor Information: Well Contractor Name NC Well Contractor Certification Number Company Name 2. Well Construction Permit #: List all applicable well permits (i.e. County, State, Variance, ,QMHFWLRQetc.) 3. Well Use (check well use): Water Supply Well: □Agricultural □Municipal/Public □Geothermal (Heating/Cooling Supply) □Residential Water Supply (single) □Industrial/Commercial □Residential Water Supply (shared) □Irrigation Non-Water Supply Well: □Monitoring □Recovery Injection Well: □Aquifer Recharge □Groundwater Remediation □Aquifer Storage and Recovery □Salinity Barrier □Aquifer Test □Stormwater Drainage □Experimental Technology □Subsidence Control □Geothermal (Closed Loop) □Tracer □Geothermal (Heating/Cooling Return) □Other (explain under #21 Remarks) 4. Date Well(s) Completed: ____________ Well ID#______________________ 5a. Well Location: Facility/Owner Name Facility ID# (if applicable) Physical Address, City, and Zip County Parcel Identification No. (PIN) 5b. Latitude and Longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) N W 6. Is (are) the well(s): □Permanent or □Temporary 7. Is this a repair to an existing well: □Yes or □No If this is a repair, fill out known well construction information and explain the nature of the repair under #21 remarks section or on the back of this form. 8. Number of wells constructed: For multiple injection or non-water supply wells ONLY with the same construction, you can submit one form. 9. Total well depth below land surface: (ft.) For multiple wells list all depths if different (example- 3@200’ and 2@100′) 10. Static water level below top of casing: (ft.) If water level is above casing, use “+” 11. Borehole diameter: (in.) 12. Well construction method: (i.e. auger, rotary, cable, direct push, etc.) FOR WATER SUPPLY WELLS ONLY: 13a. Yield (gpm) Method of test: 13b. Disinfection type: Amount: 14. WATER ZONES FROM TO DESCRIPTION ft. ft. ft. ft. 15. OUTER CASING (for multi-cased wells) OR LINER (if applicable) FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. 16. INNER CASING OR TUBING (geothermal closed-loop) FROM TO DIAMETER THICKNESS MATERIAL ft. ft. in. ft. ft. in. 17. SCREEN FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL ft. ft. in. ft. ft. in. 18. GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT ft. ft. ft. ft. ft. ft. 19. SAND/GRAVEL PACK (if applicable) FROM TO MATERIAL EMPLACEMENT METHOD ft. ft. ft. ft. 20. DRILLING LOG (attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soil/rock type, grain size, etc.) ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. 21. REMARKS 22. Certification: Signature of Certified Well Contractor Date By signing this form, I hereby certify that the well(s) was (were) constructed in accordance with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well construction details. You may also attach additional pages if necessary. SUBMITTAL INSTUCTIONS 24a. For All Wells: Submit this form within 30 days of completion of well construction to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 24b. For Injection Wells ONLY: In addition to sending the form to the address in 24a above, also submit a copy of this form within 30 days of completion of well construction to the following: Division of Water Resources, Underground Injection Control Program, 1636 Mail Service Center, Raleigh, NC 27699-1636 24c. For Water Supply & Injection Wells: Also submit one copy of this form within 30 days of completion ofwell construction to the county health department of the county whereconstructed. For Internal Use ONLY:                             APPENDIX   D                                                        Standard Field Procedures:  Revision 10.6                            Page 1  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  Standard Field Procedures Pyramid Environmental & Engineering, P.C. ________________________________________________________________________ 1.0 Equipment Decontamination Equipment decontamination is essential to assure representative environmental samples  are collected and to eliminate the potential for cross‐contamination between sample points.  Pyramid strives to clean all field equipment prior to leaving the office; however, field  decontamination is still required on most projects. The procedures for decontamination of  water level probes, hand augers, sampling probes, trowels, and other field equipment are  listed below.    1.1 EPA Region IV Decontamination Procedures   Drilling and soil sampling equipment is decontaminated prior to each use using a pressure  washer or steam cleaner. Reusable sampling equipment (hand augers, sampling probes,  trowels, split spoon samplers, water sampling equipment, etc.…) are decontaminated using  the general procedure described below.    Wash with non‐phosphate detergent, water, & brush to remove particulate matter   Rinse with tap water   Rinse with 10 percent nitric acid solution (only if sampling for metals)   Rinse with de‐ionized water   Rinse with pesticide‐grade isopropyl alcohol   Rinse with de‐ionized water   Air‐dry as long as possible   The level of decontamination used is appropriate to the analytical parameters selected and  the material of the sampling device being used for sampling. For example, if metals analyses  are required, then the 10 % nitric acid solution is used for decontamination of stainless‐steel  equipment. Pyramid uses de‐ionized or distilled water for decontamination. Equipment that  is not used immediately after decontamination is wrapped in aluminum foil prior to storage.    2.0 Soil Borings & Sampling 2.1 Soil Borings   Soil borings are used by Pyramid to investigate and characterize the subsurface at sites.       Soil borings provide information concerning soil types and density, depth to refusal, depth  to bedrock, organic vapors that may be present, and can be used to obtain samples for  laboratory analysis.   Standard Field Procedures:  Revision 10.6                            Page 2  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  Pyramid conducts borings in several different ways, using hand augers, direct‐push  equipment (Geoprobe), sample probes, split‐spoon samplers (ASTM D 1586‐84), auger  drilling, air drilling, and Vibro‐Core. The following procedures are used by Pyramid  Environmental when performing soil borings:   1. Soil boring locations are chosen, and the ULOCO utility locating service is called to  mark all public utilities. Pyramid locates private utilities at many project sites using  Pyramid locating equipment, or uses a private utility locating service.    2. Down hole drilling equipment is cleaned prior to use and between borings using  pressure washing or steam cleaning. Additional decontamination procedures in  Section 1.1 are used for sampling tools such as split spoons or direct‐push points.     3. Soil borings are advanced using direct‐push, drilling rigs, hand augers, or other  appropriate means. Near‐surface soil samples may also be collected using stainless  steel push probes, shovels, scoops, or other sampling devices.     4. Soil samples are normally collected at a minimum of 5‐foot intervals. Each sample is  divided into two parts. Soil samples for laboratory analyses are jarred from the initial  sample volume. The remaining soil is stored in a sealed container for headspace  analysis and geological description.     5. After screening the soil with the field instruments, each soil sample is described by  the field geologist and a geologic description is recorded in project documentation.    6. Soils are typically described in the field by the project geologist or soil scientist and  are classified according to the Unified Soil Classification System (ASTM D 2488‐84).    7. Soil samples selected for laboratory analysis are placed in properly prepared,  laboratory supplied containers and immediately packed in a cooler on ice. Sample  custody is maintained using standard chain‐of‐custody (COC) procedures through  delivery to the analytical laboratory.    8. Soil borings, which are not completed as monitoring wells, are grouted using a  Portland cement, bentonite, or backfilled with soil cuttings.     9. Soil cuttings are generally spread near the soil boring or monitoring well location as  directed by State regulatory managers.  Drill cuttings are drummed (containerized)  where site conditions or regulatory requirements prohibit spreading cuttings, and  are disposed off‐site (after waste determination is made).         Standard Field Procedures:  Revision 10.6                            Page 3  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  2.2 Soil Headspace Screening   Soil samples are routinely screened for volatile organic compounds (VOCs) which may be an  indication of organic or petroleum hydrocarbon contamination. The typical screening  procedure includes immediately transferring the soil from the sampling devices to a sealed  container (sealed 1‐gallon Ziplock plastic bag). The soil container is filled approximately  halfway with soil and sealed. This creates headspace above the soil in which VOCs may  accumulate. The container is allowed to stand for 5 to 15 minutes for the VOCs to equilibrate  in the headspace of the container. The headspace of the container is then screened using a  calibrated organic vapor analyzer (PID or FID). The screening is conducted by cracking the  seal only enough to allow insertion of the probe into the headspace so as not to dilute the  sample. In most cases where the contaminant of concern includes volatile organics, the  highest or “Peak“ field‐screening result is documented for each sample. The soil samples  showing the highest reading from each boring are typically selected for laboratory analysis.    2.3 Soil Sample Collection for Laboratory Analysis    After the targeted depth has been reached, soil samples are collected using a variety of  sampling devices. Soil sample devices used include split‐spoons, stainless‐steel hand augers,  stainless‐steel push‐probes and sampling scoops, and directly from the center of the  excavator bucket. The sample technician uses disposable nitrile gloves, which are changed  between samples to avoid cross‐contamination of samples, and each sampling device is  decontaminated prior to use.     Only laboratory provided containers are used for sample collection. Samples are collected  in accordance with the preservation methods required by the requested analytical method.  Samples are handled as little as possible and preserved in the field as specified for the  analytical method. The samples are stored and transported to the laboratory in an insulated  cooler chilled to approximately 4 degrees centigrade. The samples are labeled with a  minimum of the following information: Pyramid, project name or number, sample  identification, date collected, sampler name, and analysis requested. Sample custody is  maintained using standard chain‐of‐custody procedures through delivery to the analytical  laboratory. Notes of the sampling events are recorded in project documentation.  Incremental sampling methodology (ISM) is a structured composite sampling and  processing protocol that reduces data variability and provides a reasonably unbiased  estimate of mean contaminant concentrations in a volume of soil targeted for sampling.  ISM provides representative samples of specific soil volumes defined as decision units  (DUs) by collecting numerous increments of soil (typically 30–100 increments) that are  combined, processed, and subsampled according to specific protocols. ISM Sampling will  be further explained in a site‐specific Work Plan documents.  Pyramid will contract an on‐site laboratory for immediate analyses as needed.   Standard Field Procedures:  Revision 10.6                            Page 4  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  2.4 Sediment Sample Collection for Laboratory Analysis    Near surface sediment may be present in a surface water ditch, stream, or dry intermittent  stream bed. Sediment samples are typically soil related samples and may be collected with  a variety of sampling tools. Pyramid will use stainless‐steel samplers which have been  decontaminated according to the procedure detailed in section 1.1 of this document. After  the sediment samples are collected, the location, depth, conditions, and sample  composition are documented in the project records. The samples will be screened in the  field to detect volatile organic vapors and visually examined for contamination. Sediment  samples will be preserved in laboratory prepared containers in accordance with sample  preservation recommendation of the analytical laboratory. Samples are handled as little as  possible and preserved in the field as specified for the analytical method. The samples are  stored and transported in an insulated cooler chilled to approximately 4 degrees centigrade.  The samples are labeled with a minimum of the following information: Pyramid, project  name or number, sample identification, date collected, sampler name, and analysis  requested. Sample custody is maintained using standard chain‐of‐custody procedures  through delivery to the analytical laboratory. Documentation of the sampling events are  recorded in the project documentation.    3.0 Direct-Push Sampling Procedures   Direct‐push sampling techniques have been used at many sites to collect soil and  groundwater samples rapidly and inexpensively.  Track‐mounted, direct‐push rigs can access  hard to reach areas and allow borings and monitoring wells to be installed.  For soil sampling,  typically, the direct‐push steel drive tube is decontaminated using a pressure washer, and a  new plastic sample liner is inserted in the steel drive tube to collect soil samples. The soil  samples are collected in new polyethylene sample tubes within the steel drive tube. The soil  samples are then extracted from the polyethylene liner and preserved as required for  laboratory analysis.    For groundwater sampling, a steel probe with a retractable screen section and tubing are  driven to depth and the screened section is opened to allow groundwater to enter the  tubing. The water samples are withdrawn using new polyethylene and Teflon® tubing with  either a decontaminated stainless‐steel check ball, or peristaltic pump. The groundwater  sample is placed directly into the appropriate laboratory containers and sealed immediately.  To prevent cross‐contamination of samples, new disposable tubing is used for each  groundwater sample point. Disposable nitrile gloves are worn by field personnel during  development and groundwater sampling, and gloves are changed between samples.  Groundwater sampling procedures are detailed more in Section 5.0, as appropriate for each  analytical method.      Standard Field Procedures:  Revision 10.6                            Page 5  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  4.0 Monitoring Well Installation   Groundwater monitoring wells are installed in many subsurface environments; Coastal  Plain, sedimentary, Piedmont saprolite, weathered rock formations, and mountain terrains  to list a few. Formations encountered include unconsolidated and consolidated sediments,  fill material, organic soils, saprolitic soils, weathered rock formations, and bedrock.  Groundwater monitoring wells provide a stable sampling point at discrete intervals within  the confined or unconfined aquifers. Monitoring wells are installed for a number of reasons,  and are typically installed as 1‐inch, 2‐inch, 4‐inch, or 6‐inch diameter wells. Construction  may be of PVC, stainless‐steel, HDPE, or other appropriate materials. The following  procedures are used by Pyramid when performing borings and monitoring well installations.   If required, monitoring well permits are obtained from the State, County, or City.   Boring and monitoring well locations are chosen, and utilities are marked by the  public utility locating company. As needed, the locations may be scanned for utilities  by Pyramid using our locating equipment, or a private utility locating company.   In selecting a drill site, care is taken to avoid overhead power lines, and subsurface  utilities whenever possible.   Down‐hole drilling equipment is decontaminated prior to use and between borings.   Borings are advanced using direct‐push, drilling rigs, hand augers, solid‐stem augers,  hollow‐stem augers, air rotary drilling, or air hammer drilling.   Soil samples are normally collected at a minimum of 5‐foot intervals. Each sample is  divided into two parts.  Soil samples for laboratory analyses are jarred from the initial  sample volume. The remaining soil is stored in a sealed container for headspace  analysis with an organic vapor analyzer (PID or FID).    After screening the soil with the field instruments, each soil sample is described by  the field geologist and a geologic description is recorded in the project  documentation.    Type II monitoring wells are usually installed using 2‐inch diameter schedule 40 PVC riser  and 2‐inch, 0.010‐inch machine slotted well screen. The screened interval length varies with  the geologic site conditions, expected variations in water level, and the investigation goals  for the well. The well construction details are presented on the boring log.    Type III wells are usually installed as double‐cased wells to monitor the deeper portions of  the aquifer. The first casing is usually a 5 to 6‐inch diameter solid PVC well casing drilled to  bedrock or an appropriate depth within the surficial zone. The 5 to 6‐inch diameter casing  is then set and grouted in the borehole. After the cement grout has set for 12 to 24‐hours,  the borehole is completed to the desired depth using air rotary drilling or air hammer  drilling. The inside casing of the Type III monitoring well is usually constructed of 2‐inch  diameter SCH 40 PVC casing and 2‐inch diameter SCH 40 PVC 0.010‐inch slotted well screen.    Standard Field Procedures:  Revision 10.6                            Page 6  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  In most applications, a sand filter pack of #2 well sand (or appropriately sized well sand).   Sand is typically installed to a level of 2 feet above the top of the screen in each well.                    A minimum 2‐foot thick bentonite seal is usually placed on top of the filter pack and  hydrated with de‐ionized or distilled water. The remaining annular space of a typical well is  backfilled to grade with a Portland cement/bentonite grout. In monitoring wells where the  water table is close to surface, the amount of sand above the screen and bentonite will be  reduced to allow for a minimum of 2–3 feet of cement grout in the well bore.    At the surface, each well is secured with a locking cap and a steel well protector. Depending  on the surface conditions, the well may be protected by a flush‐mounted manhole set in the  surrounding surface in a concrete pad.  In some cases, stick‐up well protectors are used to  secure the well and allow the well to be more easily located in wooded or open areas.    Each groundwater monitoring well is developed by surging, pumping, or bailing to remove  sediment before sampling. Water removed during development is managed according to  individual State regulatory guidance.      5.0 Water Sampling Procedures   Pyramid relies on water sampling as a primary method for assessment of subsurface  groundwater conditions. Water sampling typically includes sampling groundwater from  monitoring wells, water supply wells, surface water bodies, stormwater,  waste sumps, etc.    The following provides typical sampling procedures for the water samples.    5.1 Monitoring Wells   Prior to sampling each monitoring well, depth to liquid and/or liquids and total well depth  are measured using a properly decontaminated electric interface probe. If phase‐separated  petroleum product is detected in a well, the product measurements are recorded along with  the water level in each well.  This information is recorded in the field record and the volume  of the water in the well casing is calculated. To purge stagnant water from each monitoring  well, three to five well casing volumes of water are removed from each well prior to  sampling. Alternately, for low‐flow sampling, development continues until the field  parameters (pH, conductivity, dissolved oxygen, ORP, and temperature) have stabilized.    If the water in the monitoring well is removed until the well is dry, then the well is sampled  thereafter. Water removed from wells during purging is managed in accordance with  individual State regulatory guidance.     Groundwater samples are typically collected using a new disposable polyethylene bailer and  a new length of nylon cord. To prevent cross‐contamination of samples between wells, a  new disposable bailer is used for each well.  The bailer is lowered into the groundwater  Standard Field Procedures:  Revision 10.6                            Page 7  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  slowly and removed slowly.  A new pair of disposable gloves is worn by field personnel  during purging and sampling, and is changed between wells.  In the case of small diameter  monitoring wells or direct‐push water samples, water samples may be collected using a  peristaltic pump and new polyethylene tubing.  Another method is to use a segment of new  sampling tubing and a stainless‐steel check ball to create a “Tube Bailer”.   Groundwater samples selected for laboratory analysis are immediately placed in properly  prepared, laboratory supplied containers and preserved in a cooler on ice. Samples are  maintained under standard chain‐of‐custody procedures from sample collection through  laboratory analysis.    5.2 Water Supply Well Sampling   Prior to sampling each water supply well, the well owner is contacted to provide access to  the well. The well owner is interviewed to locate the faucet closest to the well for sampling.     If there are no faucets located on the well, then water from an outside faucet at the building   is usually sampled. If there are no outside faucets available, then the water samples are  collected from an inside faucet. The location of the sample is recorded in the field record.   The owner is interviewed to see if there is a chlorination system on the well, or if the well  has been recently chlorinated. Recent chlorination could affect the laboratory detection  limits. In most cases, the samples are preserved using sodium thiosulfate or ascorbic acid to  remove the interactions of chlorine, which may be present in the samples.    If the well is treated with a Point‐of‐Entry (POE) treatment system, then the “raw” water  sample must be collected before the treatment system. An associated treated water sample  is usually collected as well to demonstrate effective treatment.     To purge stagnant water from the water supply well system, the faucet is allowed to run on  full stream for a minimum of 15 minutes. The aerator is removed from the tap if one is  present. Water removed from wells during purging is managed according to regulatory  standards.   Water supply well samples are collected using appropriate laboratory prepared containers  for each analysis.  The analytical methods selected will vary with the contaminant of  interest. To prevent cross‐contamination of samples between wells, disposable nitrile gloves  are worn by field personnel during purging and sampling and are changed between wells. It  is possible that samples may be required at several places within the water supply system.  The samples are collected accordingly and labeled to show the source and location sampled.   Supply well samples selected for laboratory analysis are immediately placed in properly  prepared, laboratory supplied containers and packed in a cooler on ice, and chilled to  approximately 4 degrees Celsius.  Samples are maintained under standard chain‐of‐custody  procedures from sample collection through laboratory analysis.    Standard Field Procedures:  Revision 10.6                            Page 8  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  5.3 Surface Water Sampling   Surface water samples are obtained using several techniques including use of sample  bailers, discrete depth interval samples, sample scoops, from boats, bridges, or wading into  a stream. Caution should always be used when sampling surface water to ensure that the  water collected is representative of the site conditions. Since stream or open water sampling  is transient, careful documentation of the site conditions, weather, surface conditions,  sediment, algal or biological material, etc. is required.     In many studies, additional samples from upstream and downstream of the desired sample  point are required. Surface water sampling must be planned to reflect the site‐specific  conditions during sampling. The general procedures are similar to the supply well sampling  procedures detailed above. Appropriate laboratory prepared containers are used for each  analysis. The analytical methods selected will vary with the contaminant of interest.    To prevent cross‐contamination of samples between samples, disposable nitrile gloves are  worn by field personnel during purging and sampling and are changed between samples. It  is possible that samples may be required at several places along the stream to check for  influences of up‐stream facilities.  Samples will be collected accordingly and labeled to show  the source and location sampled. Sample will always be collected upstream of the area  disturbed by the person sampling the stream. Surface water samples selected for laboratory  analysis are placed in properly prepared, laboratory supplied containers and immediately  packed in a cooler on ice. Samples are maintained under strict control using standard chain‐ of‐custody procedures through laboratory analysis.     6.0 Quality Assurance / Quality Control   The field and laboratory procedures listed above have been implemented on many sites  with excellent results. The procedures are often verified by an appropriate use of the  following environmental samples.    Trip Blanks ( or Travel blanks)  The Trip Blank (or travel blanks) are often used to verify that the environmental samples are  not impacted during shipping, and verify that the source of the glassware is not the source  of contamination. The trip blanks are preserved de‐ionized water, collected in the  laboratory, and shipped with the sample containers to Pyramid or the site. The trip blank  remains in the sample cooler and is shipped back to the laboratory with the environmental  samples. The trip blank is most commonly analyzed for volatile organic compounds (VOCs),  and correspond to the target analyses.        Standard Field Procedures:  Revision 10.6                            Page 9  Pyramid Environmental & Engineering, P.C.           Revision date 01‐06‐2020  Field Blanks   Field Blanks are quality assurance samples which are collected in the field to represent the  conditions present at the time the samples are collected. For water samples, the laboratory  containers are opened and filled in the field using de‐ionized (or distilled) water from a  known source.  The samples reflect any site conditions such as vapor sources which may  affect the water samples.  The samples then travel to the laboratory with the other samples  for analysis. Comparison of the field blank results with the sample results may indicate a  pervasive site constituent detected in the samples.     Equipment Blanks   Equipment Blanks are used to verify whether the decontamination procedures used for the  sample equipment (or the new equipment) may have added any contaminants to the  sample during collection. If a non‐disposable sampling device is used (such as a sampling  treir, scoop, hand auger, Teflon bailer, etc.…), then the decontamination of the sampling  device is usually verified using an equipment blank. The equipment blank is collected using  de‐ionized (or distilled) water from a known source. The equipment is decontaminated,   allowed to air dry, the water is poured over (or through) the equipment, and a sample is  collected in the appropriate sample containers. The equipment blank samples are preserved  with the other environmental samples, and shipped for analyses for the target parameters.    Duplicate Samples  Duplicate Samples are used to verify the sampling procedures and evaluate laboratory  analysis variability. The duplicate samples may be collected from soil, sediment, air, surface  water, wastes, or groundwater. These samples are collected and sent to the laboratory as   blind samples to have maximum effectiveness. Duplicate samples are generally analyzed for  the same analytical methods as the actual environmental sample for direct comparison.  Duplicate samples may also be split between two different laboratories to provide  verification of laboratory detection limits or quality process verification.    Background Samples  Background Samples are a tool for comparison of general site conditions with source area  site conditions. Background samples may be soil, sediment, air, surface water, waste, or  groundwater. The goal is to reflect conditions outside the expected area of contamination.  These samples are collected outside the expected area of contamination and sent to the  laboratory for analyses. Background samples are generally analyzed for the same analytical  methods as the source area environmental samples for direct comparison. Background  samples for metals comparison are common types of background samples used in  environmental investigations.                                       APPENDIX   E            #=CL# November 01, 2022 LIMS USE: FR - TIM LEATHERMAN LIMS OBJECT ID: 92631278 92631278 Project: Pace Project No.: RE: Mr. Tim Leatherman Pyramid Environmental P.O. Box 16265 503 Industrial Avenue Greensboro, NC 27416 C&H SHELL 2021-080 Dear Mr. Leatherman: Enclosed are the analytical results for sample(s) received by the laboratory on October 14, 2022. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services - Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Bonnie Vang bonnie.vang@pacelabs.com Project Manager (704)875-9092 Enclosures cc:Wyatt Copeland, Pyramid Environmental Mr. Mika Trifunovic, Pyramid Environmental REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 1 of 75 #=CP# CERTIFICATIONS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Pace Analytical Services Charlotte South Carolina Laboratory ID: 99006 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 South Carolina Laboratory ID: 99006 South Carolina Certification #: 99006001 South Carolina Drinking Water Cert. #: 99006003 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Louisiana DoH Drinking Water #: LA029 Virginia/VELAP Certification #: 460221 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 North Carolina Wastewater Certification #: 40 South Carolina Laboratory ID: 99030 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 2 of 75 #=SA# SAMPLE ANALYTE COUNT Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Lab ID Sample ID Method Analytes Reported LaboratoryAnalysts 92631278001 MW-1 (5-6)MADEP VPH 5 PASI-CTEG EPA 8260D 70 PASI-CCL SW-846 1 PASI-CKDF 92631278002 MW-2 (5-6)MADEP VPH 5 PASI-CTEG EPA 8260D 70 PASI-CCL SW-846 1 PASI-CKDF 92631278003 MW-3 (5-6)MADEP EPH 7 PASI-CAP2 MADEP VPH 5 PASI-CTEG EPA 8270E 75 PASI-CBPJ EPA 8260D 70 PASI-CCL SW-846 1 PASI-CKDF 92631278004 MW-1 EPA 504.1 4 PASI-CHH EPA 6010D 1 PASI-ADEC SM 6200B 69 PASI-CSAS 92631278005 MW-2 EPA 504.1 4 PASI-CHH EPA 6010D 1 PASI-ADEC SM 6200B 69 PASI-CCL 92631278006 MW-3 EPA 504.1 2 PASI-CHH MADEP EPH 7 PASI-CAP2 EPA 6010D 1 PASI-ADEC EPA 625.1 60 PASI-CPKS SM 6200B 63 PASI-CSAS PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 3 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-1 (5-6)Lab ID: 92631278001 Collected: 10/12/22 00:00 Received: 10/14/22 10:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: MADEP VPH Preparation Method: MADEP VPH Pace Analytical Services - Charlotte VPH NC Soil Aliphatic (C05-C08)ND mg/kg 10/28/22 19:01 N210/28/22 16:343.5 1 Aliphatic(C09-C12) Adjusted ND mg/kg 10/28/22 19:01 N210/28/22 16:343.5 1 Aromatic (C09-C10)ND mg/kg 10/28/22 19:01 N210/28/22 16:343.5 1 Surrogates 4-Bromofluorobenzene (FID) (S)99 %10/28/22 19:01 460-00-410/28/22 16:3470-130 1 4-Bromofluorobenzene (PID) (S)85 %10/28/22 19:01 460-00-410/28/22 16:3470-130 1 Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Acetone ND ug/kg 10/18/22 17:50 67-64-110/18/22 16:13145 1 Benzene 16.3 ug/kg 10/18/22 17:50 71-43-210/18/22 16:137.2 1 Bromobenzene ND ug/kg 10/18/22 17:50 108-86-110/18/22 16:137.2 1 Bromochloromethane ND ug/kg 10/18/22 17:50 74-97-510/18/22 16:137.2 1 Bromodichloromethane ND ug/kg 10/18/22 17:50 75-27-410/18/22 16:137.2 1 Bromoform ND ug/kg 10/18/22 17:50 75-25-210/18/22 16:137.2 1 Bromomethane ND ug/kg 10/18/22 17:50 74-83-910/18/22 16:1314.5 1 2-Butanone (MEK)ND ug/kg 10/18/22 17:50 78-93-310/18/22 16:13145 1 n-Butylbenzene 21.4 ug/kg 10/18/22 17:50 104-51-810/18/22 16:137.2 1 sec-Butylbenzene ND ug/kg 10/18/22 17:50 135-98-810/18/22 16:137.2 1 tert-Butylbenzene ND ug/kg 10/18/22 17:50 98-06-610/18/22 16:137.2 1 Carbon tetrachloride ND ug/kg 10/18/22 17:50 56-23-5 v210/18/22 16:137.2 1 Chlorobenzene ND ug/kg 10/18/22 17:50 108-90-710/18/22 16:137.2 1 Chloroethane ND ug/kg 10/18/22 17:50 75-00-310/18/22 16:1314.5 1 Chloroform ND ug/kg 10/18/22 17:50 67-66-310/18/22 16:137.2 1 Chloromethane ND ug/kg 10/18/22 17:50 74-87-310/18/22 16:1314.5 1 2-Chlorotoluene ND ug/kg 10/18/22 17:50 95-49-810/18/22 16:137.2 1 4-Chlorotoluene ND ug/kg 10/18/22 17:50 106-43-410/18/22 16:137.2 1 1,2-Dibromo-3-chloropropane ND ug/kg 10/18/22 17:50 96-12-810/18/22 16:137.2 1 Dibromochloromethane ND ug/kg 10/18/22 17:50 124-48-110/18/22 16:137.2 1 1,2-Dibromoethane (EDB)ND ug/kg 10/18/22 17:50 106-93-410/18/22 16:137.2 1 Dibromomethane ND ug/kg 10/18/22 17:50 74-95-310/18/22 16:137.2 1 1,2-Dichlorobenzene ND ug/kg 10/18/22 17:50 95-50-110/18/22 16:137.2 1 1,3-Dichlorobenzene ND ug/kg 10/18/22 17:50 541-73-110/18/22 16:137.2 1 1,4-Dichlorobenzene ND ug/kg 10/18/22 17:50 106-46-710/18/22 16:137.2 1 Dichlorodifluoromethane ND ug/kg 10/18/22 17:50 75-71-810/18/22 16:1314.5 1 1,1-Dichloroethane ND ug/kg 10/18/22 17:50 75-34-310/18/22 16:137.2 1 1,2-Dichloroethane ND ug/kg 10/18/22 17:50 107-06-210/18/22 16:137.2 1 1,1-Dichloroethene ND ug/kg 10/18/22 17:50 75-35-410/18/22 16:137.2 1 cis-1,2-Dichloroethene ND ug/kg 10/18/22 17:50 156-59-210/18/22 16:137.2 1 trans-1,2-Dichloroethene ND ug/kg 10/18/22 17:50 156-60-510/18/22 16:137.2 1 1,2-Dichloropropane ND ug/kg 10/18/22 17:50 78-87-510/18/22 16:137.2 1 1,3-Dichloropropane ND ug/kg 10/18/22 17:50 142-28-910/18/22 16:137.2 1 2,2-Dichloropropane ND ug/kg 10/18/22 17:50 594-20-710/18/22 16:137.2 1 1,1-Dichloropropene ND ug/kg 10/18/22 17:50 563-58-610/18/22 16:137.2 1 cis-1,3-Dichloropropene ND ug/kg 10/18/22 17:50 10061-01-510/18/22 16:137.2 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 4 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-1 (5-6)Lab ID: 92631278001 Collected: 10/12/22 00:00 Received: 10/14/22 10:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles trans-1,3-Dichloropropene ND ug/kg 10/18/22 17:50 10061-02-610/18/22 16:137.2 1 Diisopropyl ether ND ug/kg 10/18/22 17:50 108-20-310/18/22 16:137.2 1 Ethylbenzene ND ug/kg 10/18/22 17:50 100-41-410/18/22 16:137.2 1 Hexachloro-1,3-butadiene ND ug/kg 10/18/22 17:50 87-68-310/18/22 16:1314.5 1 2-Hexanone ND ug/kg 10/18/22 17:50 591-78-610/18/22 16:1372.4 1 Isopropylbenzene (Cumene)ND ug/kg 10/18/22 17:50 98-82-810/18/22 16:137.2 1 p-Isopropyltoluene ND ug/kg 10/18/22 17:50 99-87-610/18/22 16:137.2 1 Methylene Chloride ND ug/kg 10/18/22 17:50 75-09-210/18/22 16:1329.0 1 4-Methyl-2-pentanone (MIBK)ND ug/kg 10/18/22 17:50 108-10-110/18/22 16:1372.4 1 Methyl-tert-butyl ether 19.6 ug/kg 10/18/22 17:50 1634-04-410/18/22 16:137.2 1 Naphthalene ND ug/kg 10/18/22 17:50 91-20-3 C810/18/22 16:137.2 1 n-Propylbenzene ND ug/kg 10/18/22 17:50 103-65-110/18/22 16:137.2 1 Styrene ND ug/kg 10/18/22 17:50 100-42-510/18/22 16:137.2 1 1,1,1,2-Tetrachloroethane ND ug/kg 10/18/22 17:50 630-20-610/18/22 16:137.2 1 1,1,2,2-Tetrachloroethane ND ug/kg 10/18/22 17:50 79-34-510/18/22 16:137.2 1 Tetrachloroethene ND ug/kg 10/18/22 17:50 127-18-410/18/22 16:137.2 1 Toluene ND ug/kg 10/18/22 17:50 108-88-310/18/22 16:137.2 1 1,2,3-Trichlorobenzene ND ug/kg 10/18/22 17:50 87-61-610/18/22 16:137.2 1 1,2,4-Trichlorobenzene ND ug/kg 10/18/22 17:50 120-82-110/18/22 16:137.2 1 1,1,1-Trichloroethane ND ug/kg 10/18/22 17:50 71-55-610/18/22 16:137.2 1 1,1,2-Trichloroethane ND ug/kg 10/18/22 17:50 79-00-510/18/22 16:137.2 1 Trichloroethene ND ug/kg 10/18/22 17:50 79-01-610/18/22 16:137.2 1 Trichlorofluoromethane ND ug/kg 10/18/22 17:50 75-69-410/18/22 16:137.2 1 1,2,3-Trichloropropane ND ug/kg 10/18/22 17:50 96-18-410/18/22 16:137.2 1 1,2,4-Trimethylbenzene 189 ug/kg 10/18/22 17:50 95-63-610/18/22 16:137.2 1 1,3,5-Trimethylbenzene 93.1 ug/kg 10/18/22 17:50 108-67-810/18/22 16:137.2 1 Vinyl acetate ND ug/kg 10/18/22 17:50 108-05-410/18/22 16:1372.4 1 Vinyl chloride ND ug/kg 10/18/22 17:50 75-01-410/18/22 16:1314.5 1 Xylene (Total)154 ug/kg 10/18/22 17:50 1330-20-710/18/22 16:1314.5 1 m&p-Xylene 126 ug/kg 10/18/22 17:50 179601-23-110/18/22 16:1314.5 1 o-Xylene 27.1 ug/kg 10/18/22 17:50 95-47-610/18/22 16:137.2 1 Surrogates Toluene-d8 (S)100 %10/18/22 17:50 2037-26-510/18/22 16:1370-130 1 4-Bromofluorobenzene (S)102 %10/18/22 17:50 460-00-410/18/22 16:1370-130 1 1,2-Dichloroethane-d4 (S)101 %10/18/22 17:50 17060-07-010/18/22 16:1370-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 23.4 %10/18/22 14:44 N20.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 5 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-2 (5-6)Lab ID: 92631278002 Collected: 10/12/22 00:00 Received: 10/14/22 10:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: MADEP VPH Preparation Method: MADEP VPH Pace Analytical Services - Charlotte VPH NC Soil Aliphatic (C05-C08)ND mg/kg 10/28/22 19:30 N210/28/22 16:344.5 1 Aliphatic(C09-C12) Adjusted ND mg/kg 10/28/22 19:30 N210/28/22 16:344.5 1 Aromatic (C09-C10)ND mg/kg 10/28/22 19:30 N210/28/22 16:344.5 1 Surrogates 4-Bromofluorobenzene (FID) (S)99 %10/28/22 19:30 460-00-410/28/22 16:3470-130 1 4-Bromofluorobenzene (PID) (S)83 %10/28/22 19:30 460-00-410/28/22 16:3470-130 1 Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Acetone ND ug/kg 10/18/22 18:07 67-64-110/18/22 16:13148 1 Benzene 19.1 ug/kg 10/18/22 18:07 71-43-210/18/22 16:137.4 1 Bromobenzene ND ug/kg 10/18/22 18:07 108-86-110/18/22 16:137.4 1 Bromochloromethane ND ug/kg 10/18/22 18:07 74-97-510/18/22 16:137.4 1 Bromodichloromethane ND ug/kg 10/18/22 18:07 75-27-410/18/22 16:137.4 1 Bromoform ND ug/kg 10/18/22 18:07 75-25-210/18/22 16:137.4 1 Bromomethane ND ug/kg 10/18/22 18:07 74-83-910/18/22 16:1314.8 1 2-Butanone (MEK)ND ug/kg 10/18/22 18:07 78-93-310/18/22 16:13148 1 n-Butylbenzene ND ug/kg 10/18/22 18:07 104-51-810/18/22 16:137.4 1 sec-Butylbenzene 7.7 ug/kg 10/18/22 18:07 135-98-810/18/22 16:137.4 1 tert-Butylbenzene ND ug/kg 10/18/22 18:07 98-06-610/18/22 16:137.4 1 Carbon tetrachloride ND ug/kg 10/18/22 18:07 56-23-5 v210/18/22 16:137.4 1 Chlorobenzene ND ug/kg 10/18/22 18:07 108-90-710/18/22 16:137.4 1 Chloroethane ND ug/kg 10/18/22 18:07 75-00-310/18/22 16:1314.8 1 Chloroform ND ug/kg 10/18/22 18:07 67-66-310/18/22 16:137.4 1 Chloromethane ND ug/kg 10/18/22 18:07 74-87-310/18/22 16:1314.8 1 2-Chlorotoluene ND ug/kg 10/18/22 18:07 95-49-810/18/22 16:137.4 1 4-Chlorotoluene ND ug/kg 10/18/22 18:07 106-43-410/18/22 16:137.4 1 1,2-Dibromo-3-chloropropane ND ug/kg 10/18/22 18:07 96-12-810/18/22 16:137.4 1 Dibromochloromethane ND ug/kg 10/18/22 18:07 124-48-110/18/22 16:137.4 1 1,2-Dibromoethane (EDB)ND ug/kg 10/18/22 18:07 106-93-410/18/22 16:137.4 1 Dibromomethane ND ug/kg 10/18/22 18:07 74-95-310/18/22 16:137.4 1 1,2-Dichlorobenzene ND ug/kg 10/18/22 18:07 95-50-110/18/22 16:137.4 1 1,3-Dichlorobenzene ND ug/kg 10/18/22 18:07 541-73-110/18/22 16:137.4 1 1,4-Dichlorobenzene ND ug/kg 10/18/22 18:07 106-46-710/18/22 16:137.4 1 Dichlorodifluoromethane ND ug/kg 10/18/22 18:07 75-71-810/18/22 16:1314.8 1 1,1-Dichloroethane ND ug/kg 10/18/22 18:07 75-34-310/18/22 16:137.4 1 1,2-Dichloroethane ND ug/kg 10/18/22 18:07 107-06-210/18/22 16:137.4 1 1,1-Dichloroethene ND ug/kg 10/18/22 18:07 75-35-410/18/22 16:137.4 1 cis-1,2-Dichloroethene ND ug/kg 10/18/22 18:07 156-59-210/18/22 16:137.4 1 trans-1,2-Dichloroethene ND ug/kg 10/18/22 18:07 156-60-510/18/22 16:137.4 1 1,2-Dichloropropane ND ug/kg 10/18/22 18:07 78-87-510/18/22 16:137.4 1 1,3-Dichloropropane ND ug/kg 10/18/22 18:07 142-28-910/18/22 16:137.4 1 2,2-Dichloropropane ND ug/kg 10/18/22 18:07 594-20-710/18/22 16:137.4 1 1,1-Dichloropropene ND ug/kg 10/18/22 18:07 563-58-610/18/22 16:137.4 1 cis-1,3-Dichloropropene ND ug/kg 10/18/22 18:07 10061-01-510/18/22 16:137.4 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 6 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-2 (5-6)Lab ID: 92631278002 Collected: 10/12/22 00:00 Received: 10/14/22 10:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles trans-1,3-Dichloropropene ND ug/kg 10/18/22 18:07 10061-02-610/18/22 16:137.4 1 Diisopropyl ether 8.7 ug/kg 10/18/22 18:07 108-20-310/18/22 16:137.4 1 Ethylbenzene 24.4 ug/kg 10/18/22 18:07 100-41-410/18/22 16:137.4 1 Hexachloro-1,3-butadiene ND ug/kg 10/18/22 18:07 87-68-310/18/22 16:1314.8 1 2-Hexanone ND ug/kg 10/18/22 18:07 591-78-610/18/22 16:1373.9 1 Isopropylbenzene (Cumene)18.9 ug/kg 10/18/22 18:07 98-82-810/18/22 16:137.4 1 p-Isopropyltoluene 19.0 ug/kg 10/18/22 18:07 99-87-610/18/22 16:137.4 1 Methylene Chloride ND ug/kg 10/18/22 18:07 75-09-210/18/22 16:1329.6 1 4-Methyl-2-pentanone (MIBK)ND ug/kg 10/18/22 18:07 108-10-110/18/22 16:1373.9 1 Methyl-tert-butyl ether 8.3 ug/kg 10/18/22 18:07 1634-04-410/18/22 16:137.4 1 Naphthalene ND ug/kg 10/18/22 18:07 91-20-310/18/22 16:137.4 1 n-Propylbenzene 19.2 ug/kg 10/18/22 18:07 103-65-110/18/22 16:137.4 1 Styrene ND ug/kg 10/18/22 18:07 100-42-510/18/22 16:137.4 1 1,1,1,2-Tetrachloroethane ND ug/kg 10/18/22 18:07 630-20-610/18/22 16:137.4 1 1,1,2,2-Tetrachloroethane ND ug/kg 10/18/22 18:07 79-34-510/18/22 16:137.4 1 Tetrachloroethene ND ug/kg 10/18/22 18:07 127-18-410/18/22 16:137.4 1 Toluene 20.0 ug/kg 10/18/22 18:07 108-88-310/18/22 16:137.4 1 1,2,3-Trichlorobenzene ND ug/kg 10/18/22 18:07 87-61-610/18/22 16:137.4 1 1,2,4-Trichlorobenzene ND ug/kg 10/18/22 18:07 120-82-110/18/22 16:137.4 1 1,1,1-Trichloroethane ND ug/kg 10/18/22 18:07 71-55-610/18/22 16:137.4 1 1,1,2-Trichloroethane ND ug/kg 10/18/22 18:07 79-00-510/18/22 16:137.4 1 Trichloroethene ND ug/kg 10/18/22 18:07 79-01-610/18/22 16:137.4 1 Trichlorofluoromethane ND ug/kg 10/18/22 18:07 75-69-410/18/22 16:137.4 1 1,2,3-Trichloropropane ND ug/kg 10/18/22 18:07 96-18-410/18/22 16:137.4 1 1,2,4-Trimethylbenzene 26.3 ug/kg 10/18/22 18:07 95-63-610/18/22 16:137.4 1 1,3,5-Trimethylbenzene 29.1 ug/kg 10/18/22 18:07 108-67-810/18/22 16:137.4 1 Vinyl acetate ND ug/kg 10/18/22 18:07 108-05-410/18/22 16:1373.9 1 Vinyl chloride ND ug/kg 10/18/22 18:07 75-01-410/18/22 16:1314.8 1 Xylene (Total)110 ug/kg 10/18/22 18:07 1330-20-710/18/22 16:1314.8 1 m&p-Xylene 91.2 ug/kg 10/18/22 18:07 179601-23-110/18/22 16:1314.8 1 o-Xylene 18.4 ug/kg 10/18/22 18:07 95-47-610/18/22 16:137.4 1 Surrogates Toluene-d8 (S)101 %10/18/22 18:07 2037-26-510/18/22 16:1370-130 1 4-Bromofluorobenzene (S)103 %10/18/22 18:07 460-00-410/18/22 16:1370-130 1 1,2-Dichloroethane-d4 (S)103 %10/18/22 18:07 17060-07-010/18/22 16:1370-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 22.2 %10/18/22 14:44 N20.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 7 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-3 (5-6)Lab ID: 92631278003 Collected: 10/12/22 00:00 Received: 10/14/22 10:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: MADEP EPH Preparation Method: MADEP EPH Pace Analytical Services - Charlotte MADEP EPH NC Soil Aliphatic (C09-C18)ND mg/kg 10/21/22 16:15 N210/17/22 12:4913.3 1 Aliphatic (C19-C36)ND mg/kg 10/21/22 16:15 N210/17/22 12:4913.3 1 Aromatic (C11-C22)ND mg/kg 10/21/22 16:15 N210/17/22 12:4913.3 1 Surrogates 1-Chlorooctadecane (S)29 %10/21/22 16:15 3386-33-2 S210/17/22 12:4940-140 1 o-Terphenyl (S)41 %10/21/22 16:15 84-15-110/17/22 12:4940-140 1 2-Fluorobiphenyl (S)113 %10/21/22 16:15 321-60-810/17/22 12:4940-140 1 2-Bromonaphthalene (S)121 %10/21/22 16:15 580-13-210/17/22 12:4940-140 1 Analytical Method: MADEP VPH Preparation Method: MADEP VPH Pace Analytical Services - Charlotte VPH NC Soil Aliphatic (C05-C08)ND mg/kg 10/21/22 06:37 N210/19/22 11:235.6 1 Aliphatic(C09-C12) Adjusted ND mg/kg 10/21/22 06:37 N210/19/22 11:235.6 1 Aromatic (C09-C10)ND mg/kg 10/21/22 06:37 N210/19/22 11:235.6 1 Surrogates 4-Bromofluorobenzene (FID) (S)100 %10/21/22 06:37 460-00-410/19/22 11:2370-130 1 4-Bromofluorobenzene (PID) (S)114 %10/21/22 06:37 460-00-410/19/22 11:2370-130 1 Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave Acenaphthene ND ug/kg 10/19/22 13:53 83-32-910/18/22 13:09439 1 Acenaphthylene ND ug/kg 10/19/22 13:53 208-96-810/18/22 13:09439 1 Aniline ND ug/kg 10/19/22 13:53 62-53-310/18/22 13:09439 1 Anthracene ND ug/kg 10/19/22 13:53 120-12-710/18/22 13:09439 1 Benzo(a)anthracene ND ug/kg 10/19/22 13:53 56-55-310/18/22 13:09439 1 Benzo(a)pyrene ND ug/kg 10/19/22 13:53 50-32-810/18/22 13:09439 1 Benzo(b)fluoranthene ND ug/kg 10/19/22 13:53 205-99-210/18/22 13:09439 1 Benzo(g,h,i)perylene ND ug/kg 10/19/22 13:53 191-24-210/18/22 13:09439 1 Benzo(k)fluoranthene ND ug/kg 10/19/22 13:53 207-08-910/18/22 13:09439 1 Benzoic Acid ND ug/kg 10/19/22 13:53 65-85-010/18/22 13:092200 1 Benzyl alcohol ND ug/kg 10/19/22 13:53 100-51-610/18/22 13:09879 1 4-Bromophenylphenyl ether ND ug/kg 10/19/22 13:53 101-55-310/18/22 13:09439 1 Butylbenzylphthalate ND ug/kg 10/19/22 13:53 85-68-710/18/22 13:09439 1 4-Chloro-3-methylphenol ND ug/kg 10/19/22 13:53 59-50-710/18/22 13:09879 1 4-Chloroaniline ND ug/kg 10/19/22 13:53 106-47-810/18/22 13:09879 1 bis(2-Chloroethoxy)methane ND ug/kg 10/19/22 13:53 111-91-110/18/22 13:09439 1 bis(2-Chloroethyl) ether ND ug/kg 10/19/22 13:53 111-44-410/18/22 13:09439 1 2-Chloronaphthalene ND ug/kg 10/19/22 13:53 91-58-710/18/22 13:09439 1 2-Chlorophenol ND ug/kg 10/19/22 13:53 95-57-810/18/22 13:09439 1 4-Chlorophenylphenyl ether ND ug/kg 10/19/22 13:53 7005-72-310/18/22 13:09439 1 Chrysene ND ug/kg 10/19/22 13:53 218-01-910/18/22 13:09439 1 Dibenz(a,h)anthracene ND ug/kg 10/19/22 13:53 53-70-310/18/22 13:09439 1 Dibenzofuran ND ug/kg 10/19/22 13:53 132-64-910/18/22 13:09439 1 1,2-Dichlorobenzene ND ug/kg 10/19/22 13:53 95-50-110/18/22 13:09439 1 1,3-Dichlorobenzene ND ug/kg 10/19/22 13:53 541-73-110/18/22 13:09439 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 8 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-3 (5-6)Lab ID: 92631278003 Collected: 10/12/22 00:00 Received: 10/14/22 10:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave 1,4-Dichlorobenzene ND ug/kg 10/19/22 13:53 106-46-710/18/22 13:09439 1 3,3'-Dichlorobenzidine ND ug/kg 10/19/22 13:53 91-94-110/18/22 13:09879 1 2,4-Dichlorophenol ND ug/kg 10/19/22 13:53 120-83-210/18/22 13:09439 1 Diethylphthalate ND ug/kg 10/19/22 13:53 84-66-210/18/22 13:09439 1 2,4-Dimethylphenol ND ug/kg 10/19/22 13:53 105-67-910/18/22 13:09439 1 Dimethylphthalate ND ug/kg 10/19/22 13:53 131-11-310/18/22 13:09439 1 Di-n-butylphthalate ND ug/kg 10/19/22 13:53 84-74-210/18/22 13:09439 1 4,6-Dinitro-2-methylphenol ND ug/kg 10/19/22 13:53 534-52-110/18/22 13:09879 1 2,4-Dinitrophenol ND ug/kg 10/19/22 13:53 51-28-510/18/22 13:092200 1 2,4-Dinitrotoluene ND ug/kg 10/19/22 13:53 121-14-210/18/22 13:09439 1 2,6-Dinitrotoluene ND ug/kg 10/19/22 13:53 606-20-210/18/22 13:09439 1 Di-n-octylphthalate ND ug/kg 10/19/22 13:53 117-84-010/18/22 13:09439 1 bis(2-Ethylhexyl)phthalate ND ug/kg 10/19/22 13:53 117-81-7 v210/18/22 13:09439 1 Fluoranthene ND ug/kg 10/19/22 13:53 206-44-010/18/22 13:09439 1 Fluorene ND ug/kg 10/19/22 13:53 86-73-710/18/22 13:09439 1 Hexachloro-1,3-butadiene ND ug/kg 10/19/22 13:53 87-68-3 v110/18/22 13:09439 1 Hexachlorobenzene ND ug/kg 10/19/22 13:53 118-74-110/18/22 13:09439 1 Hexachlorocyclopentadiene ND ug/kg 10/19/22 13:53 77-47-410/18/22 13:09439 1 Hexachloroethane ND ug/kg 10/19/22 13:53 67-72-110/18/22 13:09439 1 Indeno(1,2,3-cd)pyrene ND ug/kg 10/19/22 13:53 193-39-510/18/22 13:09439 1 Isophorone ND ug/kg 10/19/22 13:53 78-59-110/18/22 13:09439 1 1-Methylnaphthalene ND ug/kg 10/19/22 13:53 90-12-010/18/22 13:09439 1 2-Methylnaphthalene ND ug/kg 10/19/22 13:53 91-57-610/18/22 13:09439 1 2-Methylphenol(o-Cresol)ND ug/kg 10/19/22 13:53 95-48-710/18/22 13:09439 1 3&4-Methylphenol(m&p Cresol)ND ug/kg 10/19/22 13:53 15831-10-410/18/22 13:09439 1 Naphthalene ND ug/kg 10/19/22 13:53 91-20-310/18/22 13:09439 1 2-Nitroaniline ND ug/kg 10/19/22 13:53 88-74-410/18/22 13:092200 1 3-Nitroaniline ND ug/kg 10/19/22 13:53 99-09-210/18/22 13:092200 1 4-Nitroaniline ND ug/kg 10/19/22 13:53 100-01-610/18/22 13:09879 1 Nitrobenzene ND ug/kg 10/19/22 13:53 98-95-310/18/22 13:09439 1 2-Nitrophenol ND ug/kg 10/19/22 13:53 88-75-510/18/22 13:09439 1 4-Nitrophenol ND ug/kg 10/19/22 13:53 100-02-7 v210/18/22 13:092200 1 N-Nitrosodimethylamine ND ug/kg 10/19/22 13:53 62-75-910/18/22 13:09439 1 N-Nitroso-di-n-propylamine ND ug/kg 10/19/22 13:53 621-64-710/18/22 13:09439 1 N-Nitrosodiphenylamine ND ug/kg 10/19/22 13:53 86-30-610/18/22 13:09439 1 2,2'-Oxybis(1-chloropropane)ND ug/kg 10/19/22 13:53 108-60-1 L210/18/22 13:09439 1 Pentachlorophenol ND ug/kg 10/19/22 13:53 87-86-5 v210/18/22 13:09879 1 Phenanthrene ND ug/kg 10/19/22 13:53 85-01-810/18/22 13:09439 1 Phenol ND ug/kg 10/19/22 13:53 108-95-210/18/22 13:09439 1 Pyrene ND ug/kg 10/19/22 13:53 129-00-010/18/22 13:09439 1 Pyridine ND ug/kg 10/19/22 13:53 110-86-110/18/22 13:09439 1 1,2,4-Trichlorobenzene ND ug/kg 10/19/22 13:53 120-82-110/18/22 13:09439 1 2,4,5-Trichlorophenol ND ug/kg 10/19/22 13:53 95-95-410/18/22 13:09439 1 2,4,6-Trichlorophenol ND ug/kg 10/19/22 13:53 88-06-210/18/22 13:09439 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 9 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-3 (5-6)Lab ID: 92631278003 Collected: 10/12/22 00:00 Received: 10/14/22 10:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 8270E Preparation Method: EPA 3546 Pace Analytical Services - Charlotte 8270E MSSV Microwave Surrogates Nitrobenzene-d5 (S)62 %10/19/22 13:53 4165-60-010/18/22 13:0910-130 1 2-Fluorobiphenyl (S)48 %10/19/22 13:53 321-60-810/18/22 13:0910-130 1 Terphenyl-d14 (S)71 %10/19/22 13:53 1718-51-010/18/22 13:0910-130 1 Phenol-d6 (S)52 %10/19/22 13:53 13127-88-310/18/22 13:0910-130 1 2-Fluorophenol (S)49 %10/19/22 13:53 367-12-410/18/22 13:0910-130 1 2,4,6-Tribromophenol (S)58 %10/19/22 13:53 118-79-610/18/22 13:0910-131 1 Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles Acetone ND ug/kg 10/18/22 18:24 67-64-110/18/22 16:13178 1 Benzene ND ug/kg 10/18/22 18:24 71-43-210/18/22 16:138.9 1 Bromobenzene ND ug/kg 10/18/22 18:24 108-86-110/18/22 16:138.9 1 Bromochloromethane ND ug/kg 10/18/22 18:24 74-97-510/18/22 16:138.9 1 Bromodichloromethane ND ug/kg 10/18/22 18:24 75-27-410/18/22 16:138.9 1 Bromoform ND ug/kg 10/18/22 18:24 75-25-210/18/22 16:138.9 1 Bromomethane ND ug/kg 10/18/22 18:24 74-83-910/18/22 16:1317.8 1 2-Butanone (MEK)ND ug/kg 10/18/22 18:24 78-93-310/18/22 16:13178 1 n-Butylbenzene ND ug/kg 10/18/22 18:24 104-51-810/18/22 16:138.9 1 sec-Butylbenzene ND ug/kg 10/18/22 18:24 135-98-810/18/22 16:138.9 1 tert-Butylbenzene ND ug/kg 10/18/22 18:24 98-06-610/18/22 16:138.9 1 Carbon tetrachloride ND ug/kg 10/18/22 18:24 56-23-5 v210/18/22 16:138.9 1 Chlorobenzene ND ug/kg 10/18/22 18:24 108-90-710/18/22 16:138.9 1 Chloroethane ND ug/kg 10/18/22 18:24 75-00-310/18/22 16:1317.8 1 Chloroform 27.4 ug/kg 10/18/22 18:24 67-66-310/18/22 16:138.9 1 Chloromethane ND ug/kg 10/18/22 18:24 74-87-310/18/22 16:1317.8 1 2-Chlorotoluene ND ug/kg 10/18/22 18:24 95-49-810/18/22 16:138.9 1 4-Chlorotoluene ND ug/kg 10/18/22 18:24 106-43-410/18/22 16:138.9 1 1,2-Dibromo-3-chloropropane ND ug/kg 10/18/22 18:24 96-12-810/18/22 16:138.9 1 Dibromochloromethane ND ug/kg 10/18/22 18:24 124-48-110/18/22 16:138.9 1 1,2-Dibromoethane (EDB)ND ug/kg 10/18/22 18:24 106-93-410/18/22 16:138.9 1 Dibromomethane ND ug/kg 10/18/22 18:24 74-95-310/18/22 16:138.9 1 1,2-Dichlorobenzene ND ug/kg 10/18/22 18:24 95-50-110/18/22 16:138.9 1 1,3-Dichlorobenzene ND ug/kg 10/18/22 18:24 541-73-110/18/22 16:138.9 1 1,4-Dichlorobenzene ND ug/kg 10/18/22 18:24 106-46-710/18/22 16:138.9 1 Dichlorodifluoromethane ND ug/kg 10/18/22 18:24 75-71-810/18/22 16:1317.8 1 1,1-Dichloroethane ND ug/kg 10/18/22 18:24 75-34-310/18/22 16:138.9 1 1,2-Dichloroethane ND ug/kg 10/18/22 18:24 107-06-210/18/22 16:138.9 1 1,1-Dichloroethene ND ug/kg 10/18/22 18:24 75-35-410/18/22 16:138.9 1 cis-1,2-Dichloroethene ND ug/kg 10/18/22 18:24 156-59-210/18/22 16:138.9 1 trans-1,2-Dichloroethene ND ug/kg 10/18/22 18:24 156-60-510/18/22 16:138.9 1 1,2-Dichloropropane ND ug/kg 10/18/22 18:24 78-87-510/18/22 16:138.9 1 1,3-Dichloropropane ND ug/kg 10/18/22 18:24 142-28-910/18/22 16:138.9 1 2,2-Dichloropropane ND ug/kg 10/18/22 18:24 594-20-710/18/22 16:138.9 1 1,1-Dichloropropene ND ug/kg 10/18/22 18:24 563-58-610/18/22 16:138.9 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 10 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-3 (5-6)Lab ID: 92631278003 Collected: 10/12/22 00:00 Received: 10/14/22 10:15 Matrix: Solid Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions. Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 8260D Preparation Method: EPA 5035A/5030B Pace Analytical Services - Charlotte 8260D/5035A/5030B Volatiles cis-1,3-Dichloropropene ND ug/kg 10/18/22 18:24 10061-01-510/18/22 16:138.9 1 trans-1,3-Dichloropropene ND ug/kg 10/18/22 18:24 10061-02-610/18/22 16:138.9 1 Diisopropyl ether ND ug/kg 10/18/22 18:24 108-20-310/18/22 16:138.9 1 Ethylbenzene ND ug/kg 10/18/22 18:24 100-41-410/18/22 16:138.9 1 Hexachloro-1,3-butadiene ND ug/kg 10/18/22 18:24 87-68-310/18/22 16:1317.8 1 2-Hexanone ND ug/kg 10/18/22 18:24 591-78-610/18/22 16:1388.8 1 Isopropylbenzene (Cumene)ND ug/kg 10/18/22 18:24 98-82-810/18/22 16:138.9 1 p-Isopropyltoluene ND ug/kg 10/18/22 18:24 99-87-610/18/22 16:138.9 1 Methylene Chloride ND ug/kg 10/18/22 18:24 75-09-210/18/22 16:1335.5 1 4-Methyl-2-pentanone (MIBK)ND ug/kg 10/18/22 18:24 108-10-110/18/22 16:1388.8 1 Methyl-tert-butyl ether ND ug/kg 10/18/22 18:24 1634-04-410/18/22 16:138.9 1 Naphthalene ND ug/kg 10/18/22 18:24 91-20-310/18/22 16:138.9 1 n-Propylbenzene ND ug/kg 10/18/22 18:24 103-65-110/18/22 16:138.9 1 Styrene ND ug/kg 10/18/22 18:24 100-42-510/18/22 16:138.9 1 1,1,1,2-Tetrachloroethane ND ug/kg 10/18/22 18:24 630-20-610/18/22 16:138.9 1 1,1,2,2-Tetrachloroethane ND ug/kg 10/18/22 18:24 79-34-510/18/22 16:138.9 1 Tetrachloroethene 34.8 ug/kg 10/18/22 18:24 127-18-410/18/22 16:138.9 1 Toluene 78.0 ug/kg 10/18/22 18:24 108-88-310/18/22 16:138.9 1 1,2,3-Trichlorobenzene ND ug/kg 10/18/22 18:24 87-61-610/18/22 16:138.9 1 1,2,4-Trichlorobenzene ND ug/kg 10/18/22 18:24 120-82-110/18/22 16:138.9 1 1,1,1-Trichloroethane ND ug/kg 10/18/22 18:24 71-55-610/18/22 16:138.9 1 1,1,2-Trichloroethane ND ug/kg 10/18/22 18:24 79-00-510/18/22 16:138.9 1 Trichloroethene ND ug/kg 10/18/22 18:24 79-01-610/18/22 16:138.9 1 Trichlorofluoromethane ND ug/kg 10/18/22 18:24 75-69-410/18/22 16:138.9 1 1,2,3-Trichloropropane ND ug/kg 10/18/22 18:24 96-18-410/18/22 16:138.9 1 1,2,4-Trimethylbenzene 9.6 ug/kg 10/18/22 18:24 95-63-610/18/22 16:138.9 1 1,3,5-Trimethylbenzene ND ug/kg 10/18/22 18:24 108-67-810/18/22 16:138.9 1 Vinyl acetate ND ug/kg 10/18/22 18:24 108-05-410/18/22 16:1388.8 1 Vinyl chloride ND ug/kg 10/18/22 18:24 75-01-410/18/22 16:1317.8 1 Xylene (Total)20.9 ug/kg 10/18/22 18:24 1330-20-710/18/22 16:1317.8 1 m&p-Xylene 20.9 ug/kg 10/18/22 18:24 179601-23-110/18/22 16:1317.8 1 o-Xylene ND ug/kg 10/18/22 18:24 95-47-610/18/22 16:138.9 1 Surrogates Toluene-d8 (S)102 %10/18/22 18:24 2037-26-510/18/22 16:1370-130 1 4-Bromofluorobenzene (S)102 %10/18/22 18:24 460-00-410/18/22 16:1370-130 1 1,2-Dichloroethane-d4 (S)101 %10/18/22 18:24 17060-07-010/18/22 16:1370-130 1 Analytical Method: SW-846 Pace Analytical Services - Charlotte Percent Moisture Percent Moisture 26.1 %10/18/22 14:44 N20.10 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 11 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-1 Lab ID: 92631278004 Collected: 10/13/22 00:00 Received: 10/14/22 10:15 Matrix: Water Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 504.1 Preparation Method: EPA 504.1 Pace Analytical Services - Charlotte 504 GCS EDB and DBCP 1,2-Dibromo-3-chloropropane ND ug/L 10/24/22 21:42 96-12-810/24/22 11:220.049 1 1,2-Dibromoethane (EDB)ND ug/L 10/24/22 21:42 106-93-410/24/22 11:220.020 1 1,2,3-Trichloropropane ND ug/L 10/24/22 21:42 96-18-410/24/22 11:220.049 1 Surrogates 1-Chloro-2-bromopropane (S)100 %10/24/22 21:42 301-79-5610/24/22 11:2270-130 1 Analytical Method: EPA 6010D Preparation Method: EPA 3010A Pace Analytical Services - Asheville 6010 MET ICP Lead ND ug/L 10/27/22 17:13 7439-92-110/26/22 11:565.0 1 Analytical Method: SM 6200B Pace Analytical Services - Charlotte 6200B MSV tert-Amyl Alcohol ND ug/L 10/25/22 00:44 75-85-4100 1 tert-Amylmethyl ether ND ug/L 10/25/22 00:44 994-05-810.0 1 Benzene 11.9 ug/L 10/25/22 00:44 71-43-2 M10.50 1 Bromobenzene ND ug/L 10/25/22 00:44 108-86-10.50 1 Bromochloromethane ND ug/L 10/25/22 00:44 74-97-50.50 1 Bromodichloromethane ND ug/L 10/25/22 00:44 75-27-40.50 1 Bromoform ND ug/L 10/25/22 00:44 75-25-20.50 1 Bromomethane ND ug/L 10/25/22 00:44 74-83-95.0 1 tert-Butyl Alcohol ND ug/L 10/25/22 00:44 75-65-050.0 1 n-Butylbenzene 51.2 ug/L 10/25/22 00:44 104-51-80.50 1 sec-Butylbenzene 22.3 ug/L 10/25/22 00:44 135-98-80.50 1 tert-Butylbenzene 0.62 ug/L 10/25/22 00:44 98-06-60.50 1 tert-Butyl Formate ND ug/L 10/25/22 00:44 762-75-4 M150.0 1 Carbon tetrachloride ND ug/L 10/25/22 00:44 56-23-50.50 1 Chlorobenzene ND ug/L 10/25/22 00:44 108-90-70.50 1 Chloroethane ND ug/L 10/25/22 00:44 75-00-31.0 1 Chloroform ND ug/L 10/25/22 00:44 67-66-30.50 1 Chloromethane ND ug/L 10/25/22 00:44 74-87-31.0 1 2-Chlorotoluene ND ug/L 10/25/22 00:44 95-49-80.50 1 4-Chlorotoluene ND ug/L 10/25/22 00:44 106-43-40.50 1 1,2-Dibromo-3-chloropropane ND ug/L 10/25/22 00:44 96-12-81.0 1 Dibromochloromethane ND ug/L 10/25/22 00:44 124-48-10.50 1 1,2-Dibromoethane (EDB)ND ug/L 10/25/22 00:44 106-93-40.50 1 Dibromomethane ND ug/L 10/25/22 00:44 74-95-30.50 1 1,2-Dichlorobenzene ND ug/L 10/25/22 00:44 95-50-10.50 1 1,3-Dichlorobenzene ND ug/L 10/25/22 00:44 541-73-10.50 1 1,4-Dichlorobenzene ND ug/L 10/25/22 00:44 106-46-70.50 1 Dichlorodifluoromethane ND ug/L 10/25/22 00:44 75-71-80.50 1 1,1-Dichloroethane ND ug/L 10/25/22 00:44 75-34-30.50 1 1,2-Dichloroethane ND ug/L 10/25/22 00:44 107-06-20.50 1 1,1-Dichloroethene ND ug/L 10/25/22 00:44 75-35-40.50 1 cis-1,2-Dichloroethene ND ug/L 10/25/22 00:44 156-59-20.50 1 trans-1,2-Dichloroethene ND ug/L 10/25/22 00:44 156-60-50.50 1 1,2-Dichloropropane ND ug/L 10/25/22 00:44 78-87-50.50 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 12 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-1 Lab ID: 92631278004 Collected: 10/13/22 00:00 Received: 10/14/22 10:15 Matrix: Water Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: SM 6200B Pace Analytical Services - Charlotte 6200B MSV 1,3-Dichloropropane ND ug/L 10/25/22 00:44 142-28-90.50 1 2,2-Dichloropropane ND ug/L 10/25/22 00:44 594-20-70.50 1 1,1-Dichloropropene ND ug/L 10/25/22 00:44 563-58-60.50 1 cis-1,3-Dichloropropene ND ug/L 10/25/22 00:44 10061-01-50.50 1 trans-1,3-Dichloropropene ND ug/L 10/25/22 00:44 10061-02-60.50 1 Diisopropyl ether 7.6 ug/L 10/25/22 00:44 108-20-3 M10.50 1 Ethanol ND ug/L 10/25/22 00:44 64-17-5200 1 Ethylbenzene 2.9 ug/L 10/25/22 00:44 100-41-40.50 1 Ethyl-tert-butyl ether ND ug/L 10/25/22 00:44 637-92-310.0 1 Hexachloro-1,3-butadiene ND ug/L 10/25/22 00:44 87-68-32.0 1 Isopropylbenzene (Cumene)23.6 ug/L 10/25/22 00:44 98-82-8 M10.50 1 Methylene Chloride ND ug/L 10/25/22 00:44 75-09-22.0 1 Methyl-tert-butyl ether 4.3 ug/L 10/25/22 00:44 1634-04-40.50 1 Naphthalene 38.6 ug/L 10/25/22 00:44 91-20-3 M12.0 1 n-Propylbenzene 95.1 ug/L 10/25/22 00:44 103-65-1 M10.50 1 Styrene ND ug/L 10/25/22 00:44 100-42-50.50 1 1,1,1,2-Tetrachloroethane ND ug/L 10/25/22 00:44 630-20-60.50 1 1,1,2,2-Tetrachloroethane ND ug/L 10/25/22 00:44 79-34-50.50 1 Tetrachloroethene ND ug/L 10/25/22 00:44 127-18-40.50 1 Toluene 0.51 ug/L 10/25/22 00:44 108-88-30.50 1 1,2,3-Trichlorobenzene ND ug/L 10/25/22 00:44 87-61-62.0 1 1,2,4-Trichlorobenzene ND ug/L 10/25/22 00:44 120-82-12.0 1 1,1,1-Trichloroethane ND ug/L 10/25/22 00:44 71-55-60.50 1 1,1,2-Trichloroethane ND ug/L 10/25/22 00:44 79-00-50.50 1 Trichloroethene ND ug/L 10/25/22 00:44 79-01-60.50 1 Trichlorofluoromethane ND ug/L 10/25/22 00:44 75-69-41.0 1 1,2,3-Trichloropropane ND ug/L 10/25/22 00:44 96-18-40.50 1 1,2,4-Trimethylbenzene 0.88 ug/L 10/25/22 00:44 95-63-60.50 1 1,3,5-Trimethylbenzene ND ug/L 10/25/22 00:44 108-67-80.50 1 Vinyl chloride ND ug/L 10/25/22 00:44 75-01-41.0 1 m&p-Xylene 2.3 ug/L 10/25/22 00:44 179601-23-11.0 1 o-Xylene 0.53 ug/L 10/25/22 00:44 95-47-60.50 1 Surrogates 1,2-Dichloroethane-d4 (S)96 %10/25/22 00:44 17060-07-070-130 1 4-Bromofluorobenzene (S)107 %10/25/22 00:44 460-00-470-130 1 Toluene-d8 (S)92 %10/25/22 00:44 2037-26-570-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 13 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-2 Lab ID: 92631278005 Collected: 10/13/22 00:00 Received: 10/14/22 10:15 Matrix: Water Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 504.1 Preparation Method: EPA 504.1 Pace Analytical Services - Charlotte 504 GCS EDB and DBCP 1,2-Dibromo-3-chloropropane ND ug/L 10/24/22 21:52 96-12-810/24/22 11:220.049 1 1,2-Dibromoethane (EDB)ND ug/L 10/24/22 21:52 106-93-410/24/22 11:220.019 1 1,2,3-Trichloropropane ND ug/L 10/24/22 21:52 96-18-410/24/22 11:220.049 1 Surrogates 1-Chloro-2-bromopropane (S)102 %10/24/22 21:52 301-79-5610/24/22 11:2270-130 1 Analytical Method: EPA 6010D Preparation Method: EPA 3010A Pace Analytical Services - Asheville 6010 MET ICP Lead ND ug/L 10/27/22 17:16 7439-92-110/26/22 11:565.0 1 Analytical Method: SM 6200B Pace Analytical Services - Charlotte 6200B MSV tert-Amyl Alcohol ND ug/L 10/25/22 16:07 75-85-4100 1 tert-Amylmethyl ether ND ug/L 10/25/22 16:07 994-05-810.0 1 Benzene ND ug/L 10/25/22 16:07 71-43-20.50 1 Bromobenzene ND ug/L 10/25/22 16:07 108-86-10.50 1 Bromochloromethane ND ug/L 10/25/22 16:07 74-97-50.50 1 Bromodichloromethane ND ug/L 10/25/22 16:07 75-27-40.50 1 Bromoform ND ug/L 10/25/22 16:07 75-25-20.50 1 Bromomethane ND ug/L 10/25/22 16:07 74-83-95.0 1 tert-Butyl Alcohol ND ug/L 10/25/22 16:07 75-65-050.0 1 n-Butylbenzene ND ug/L 10/25/22 16:07 104-51-80.50 1 sec-Butylbenzene ND ug/L 10/25/22 16:07 135-98-80.50 1 tert-Butylbenzene ND ug/L 10/25/22 16:07 98-06-60.50 1 tert-Butyl Formate ND ug/L 10/25/22 16:07 762-75-450.0 1 Carbon tetrachloride ND ug/L 10/25/22 16:07 56-23-50.50 1 Chlorobenzene ND ug/L 10/25/22 16:07 108-90-70.50 1 Chloroethane ND ug/L 10/25/22 16:07 75-00-31.0 1 Chloroform ND ug/L 10/25/22 16:07 67-66-30.50 1 Chloromethane 1.1 ug/L 10/25/22 16:07 74-87-31.0 1 2-Chlorotoluene ND ug/L 10/25/22 16:07 95-49-80.50 1 4-Chlorotoluene ND ug/L 10/25/22 16:07 106-43-40.50 1 1,2-Dibromo-3-chloropropane ND ug/L 10/25/22 16:07 96-12-81.0 1 Dibromochloromethane ND ug/L 10/25/22 16:07 124-48-10.50 1 1,2-Dibromoethane (EDB)ND ug/L 10/25/22 16:07 106-93-40.50 1 Dibromomethane ND ug/L 10/25/22 16:07 74-95-30.50 1 1,2-Dichlorobenzene ND ug/L 10/25/22 16:07 95-50-10.50 1 1,3-Dichlorobenzene ND ug/L 10/25/22 16:07 541-73-10.50 1 1,4-Dichlorobenzene ND ug/L 10/25/22 16:07 106-46-70.50 1 Dichlorodifluoromethane ND ug/L 10/25/22 16:07 75-71-80.50 1 1,1-Dichloroethane ND ug/L 10/25/22 16:07 75-34-30.50 1 1,2-Dichloroethane ND ug/L 10/25/22 16:07 107-06-20.50 1 1,1-Dichloroethene ND ug/L 10/25/22 16:07 75-35-40.50 1 cis-1,2-Dichloroethene ND ug/L 10/25/22 16:07 156-59-20.50 1 trans-1,2-Dichloroethene ND ug/L 10/25/22 16:07 156-60-50.50 1 1,2-Dichloropropane ND ug/L 10/25/22 16:07 78-87-50.50 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 14 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-2 Lab ID: 92631278005 Collected: 10/13/22 00:00 Received: 10/14/22 10:15 Matrix: Water Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: SM 6200B Pace Analytical Services - Charlotte 6200B MSV 1,3-Dichloropropane ND ug/L 10/25/22 16:07 142-28-90.50 1 2,2-Dichloropropane ND ug/L 10/25/22 16:07 594-20-70.50 1 1,1-Dichloropropene ND ug/L 10/25/22 16:07 563-58-60.50 1 cis-1,3-Dichloropropene ND ug/L 10/25/22 16:07 10061-01-50.50 1 trans-1,3-Dichloropropene ND ug/L 10/25/22 16:07 10061-02-60.50 1 Diisopropyl ether ND ug/L 10/25/22 16:07 108-20-30.50 1 Ethanol ND ug/L 10/25/22 16:07 64-17-5200 1 Ethylbenzene ND ug/L 10/25/22 16:07 100-41-40.50 1 Ethyl-tert-butyl ether ND ug/L 10/25/22 16:07 637-92-310.0 1 Hexachloro-1,3-butadiene ND ug/L 10/25/22 16:07 87-68-32.0 1 Isopropylbenzene (Cumene)ND ug/L 10/25/22 16:07 98-82-80.50 1 Methylene Chloride ND ug/L 10/25/22 16:07 75-09-22.0 1 Methyl-tert-butyl ether ND ug/L 10/25/22 16:07 1634-04-40.50 1 Naphthalene ND ug/L 10/25/22 16:07 91-20-32.0 1 n-Propylbenzene ND ug/L 10/25/22 16:07 103-65-10.50 1 Styrene ND ug/L 10/25/22 16:07 100-42-50.50 1 1,1,1,2-Tetrachloroethane ND ug/L 10/25/22 16:07 630-20-60.50 1 1,1,2,2-Tetrachloroethane ND ug/L 10/25/22 16:07 79-34-50.50 1 Tetrachloroethene ND ug/L 10/25/22 16:07 127-18-40.50 1 Toluene ND ug/L 10/25/22 16:07 108-88-30.50 1 1,2,3-Trichlorobenzene ND ug/L 10/25/22 16:07 87-61-62.0 1 1,2,4-Trichlorobenzene ND ug/L 10/25/22 16:07 120-82-12.0 1 1,1,1-Trichloroethane ND ug/L 10/25/22 16:07 71-55-60.50 1 1,1,2-Trichloroethane ND ug/L 10/25/22 16:07 79-00-50.50 1 Trichloroethene ND ug/L 10/25/22 16:07 79-01-60.50 1 Trichlorofluoromethane ND ug/L 10/25/22 16:07 75-69-41.0 1 1,2,3-Trichloropropane ND ug/L 10/25/22 16:07 96-18-40.50 1 1,2,4-Trimethylbenzene ND ug/L 10/25/22 16:07 95-63-60.50 1 1,3,5-Trimethylbenzene ND ug/L 10/25/22 16:07 108-67-80.50 1 Vinyl chloride ND ug/L 10/25/22 16:07 75-01-41.0 1 m&p-Xylene ND ug/L 10/25/22 16:07 179601-23-11.0 1 o-Xylene ND ug/L 10/25/22 16:07 95-47-60.50 1 Surrogates 1,2-Dichloroethane-d4 (S)105 %10/25/22 16:07 17060-07-070-130 1 4-Bromofluorobenzene (S)97 %10/25/22 16:07 460-00-470-130 1 Toluene-d8 (S)103 %10/25/22 16:07 2037-26-570-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 15 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-3 Lab ID: 92631278006 Collected: 10/13/22 00:00 Received: 10/14/22 10:15 Matrix: Water Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 504.1 Preparation Method: EPA 504.1 Pace Analytical Services - Charlotte 504 GCS EDB and DBCP 1,2-Dibromoethane (EDB)ND ug/L 10/24/22 22:03 106-93-410/24/22 11:220.020 1 Surrogates 1-Chloro-2-bromopropane (S)100 %10/24/22 22:03 301-79-5610/24/22 11:2270-130 1 Analytical Method: MADEP EPH Preparation Method: MADEP EPH Pace Analytical Services - Charlotte MADEP EPH NC Water Aliphatic (C09-C18)ND ug/L 10/25/22 16:06 N210/24/22 10:3399.0 1 Aliphatic (C19-C36)ND ug/L 10/25/22 16:06 N210/24/22 10:3399.0 1 Aromatic (C11-C22)ND ug/L 10/25/22 16:06 N210/24/22 10:3399.0 1 Surrogates 1-Chlorooctadecane (S)48 %10/25/22 16:06 3386-33-210/24/22 10:3340-140 1 o-Terphenyl (S)82 %10/25/22 16:06 84-15-110/24/22 10:3340-140 1 2-Fluorobiphenyl (S)123 %10/25/22 16:06 321-60-810/24/22 10:3340-140 1 2-Bromonaphthalene (S)128 %10/25/22 16:06 580-13-210/24/22 10:3340-140 1 Analytical Method: EPA 6010D Preparation Method: EPA 3010A Pace Analytical Services - Asheville 6010 MET ICP Lead ND ug/L 10/27/22 17:20 7439-92-110/26/22 11:565.0 1 Analytical Method: EPA 625.1 Preparation Method: EPA 625.1 Pace Analytical Services - Charlotte 625 RVE Acenaphthene ND ug/L 10/21/22 15:42 83-32-910/20/22 14:415.0 1 Acenaphthylene ND ug/L 10/21/22 15:42 208-96-810/20/22 14:415.0 1 Anthracene ND ug/L 10/21/22 15:42 120-12-710/20/22 14:415.0 1 Benzo(a)anthracene ND ug/L 10/21/22 15:42 56-55-310/20/22 14:415.0 1 Benzo(a)pyrene ND ug/L 10/21/22 15:42 50-32-810/20/22 14:415.0 1 Benzo(b)fluoranthene ND ug/L 10/21/22 15:42 205-99-210/20/22 14:415.0 1 Benzo(g,h,i)perylene ND ug/L 10/21/22 15:42 191-24-210/20/22 14:415.0 1 Benzo(k)fluoranthene ND ug/L 10/21/22 15:42 207-08-910/20/22 14:415.0 1 4-Bromophenylphenyl ether ND ug/L 10/21/22 15:42 101-55-310/20/22 14:415.0 1 Butylbenzylphthalate ND ug/L 10/21/22 15:42 85-68-710/20/22 14:415.0 1 4-Chloro-3-methylphenol ND ug/L 10/21/22 15:42 59-50-710/20/22 14:415.0 1 bis(2-Chloroethoxy)methane ND ug/L 10/21/22 15:42 111-91-110/20/22 14:4110.0 1 bis(2-Chloroethyl) ether ND ug/L 10/21/22 15:42 111-44-410/20/22 14:415.0 1 2-Chloronaphthalene ND ug/L 10/21/22 15:42 91-58-710/20/22 14:415.0 1 2-Chlorophenol ND ug/L 10/21/22 15:42 95-57-810/20/22 14:415.0 1 4-Chlorophenylphenyl ether ND ug/L 10/21/22 15:42 7005-72-310/20/22 14:415.0 1 Chrysene ND ug/L 10/21/22 15:42 218-01-910/20/22 14:415.0 1 Dibenz(a,h)anthracene ND ug/L 10/21/22 15:42 53-70-310/20/22 14:415.0 1 3,3'-Dichlorobenzidine ND ug/L 10/21/22 15:42 91-94-110/20/22 14:4110.0 1 2,4-Dichlorophenol ND ug/L 10/21/22 15:42 120-83-210/20/22 14:415.0 1 Diethylphthalate ND ug/L 10/21/22 15:42 84-66-210/20/22 14:415.0 1 2,4-Dimethylphenol ND ug/L 10/21/22 15:42 105-67-9 L110/20/22 14:4110.0 1 Dimethylphthalate ND ug/L 10/21/22 15:42 131-11-310/20/22 14:415.0 1 Di-n-butylphthalate ND ug/L 10/21/22 15:42 84-74-210/20/22 14:415.0 1 4,6-Dinitro-2-methylphenol ND ug/L 10/21/22 15:42 534-52-110/20/22 14:4110.0 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 16 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-3 Lab ID: 92631278006 Collected: 10/13/22 00:00 Received: 10/14/22 10:15 Matrix: Water Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: EPA 625.1 Preparation Method: EPA 625.1 Pace Analytical Services - Charlotte 625 RVE 2,4-Dinitrophenol ND ug/L 10/21/22 15:42 51-28-510/20/22 14:4150.0 1 2,4-Dinitrotoluene ND ug/L 10/21/22 15:42 121-14-210/20/22 14:415.0 1 2,6-Dinitrotoluene ND ug/L 10/21/22 15:42 606-20-210/20/22 14:415.0 1 Di-n-octylphthalate ND ug/L 10/21/22 15:42 117-84-010/20/22 14:415.0 1 bis(2-Ethylhexyl)phthalate ND ug/L 10/21/22 15:42 117-81-710/20/22 14:415.0 1 Fluoranthene ND ug/L 10/21/22 15:42 206-44-010/20/22 14:415.0 1 Fluorene ND ug/L 10/21/22 15:42 86-73-710/20/22 14:415.0 1 Hexachloro-1,3-butadiene ND ug/L 10/21/22 15:42 87-68-310/20/22 14:415.0 1 Hexachlorobenzene ND ug/L 10/21/22 15:42 118-74-110/20/22 14:415.0 1 Hexachlorocyclopentadiene ND ug/L 10/21/22 15:42 77-47-410/20/22 14:4110.0 1 Hexachloroethane ND ug/L 10/21/22 15:42 67-72-110/20/22 14:415.0 1 Indeno(1,2,3-cd)pyrene ND ug/L 10/21/22 15:42 193-39-510/20/22 14:415.0 1 Isophorone ND ug/L 10/21/22 15:42 78-59-110/20/22 14:4110.0 1 Naphthalene ND ug/L 10/21/22 15:42 91-20-310/20/22 14:415.0 1 Nitrobenzene ND ug/L 10/21/22 15:42 98-95-310/20/22 14:415.0 1 2-Nitrophenol ND ug/L 10/21/22 15:42 88-75-510/20/22 14:415.0 1 4-Nitrophenol ND ug/L 10/21/22 15:42 100-02-710/20/22 14:4110.0 1 N-Nitrosodimethylamine ND ug/L 10/21/22 15:42 62-75-910/20/22 14:415.0 1 N-Nitroso-di-n-propylamine ND ug/L 10/21/22 15:42 621-64-710/20/22 14:415.0 1 N-Nitrosodiphenylamine ND ug/L 10/21/22 15:42 86-30-610/20/22 14:4110.0 1 Pentachlorophenol ND ug/L 10/21/22 15:42 87-86-510/20/22 14:4110.0 1 Phenanthrene ND ug/L 10/21/22 15:42 85-01-810/20/22 14:415.0 1 Phenol ND ug/L 10/21/22 15:42 108-95-210/20/22 14:415.0 1 Pyrene ND ug/L 10/21/22 15:42 129-00-010/20/22 14:415.0 1 1,2,4-Trichlorobenzene ND ug/L 10/21/22 15:42 120-82-110/20/22 14:415.0 1 2,4,6-Trichlorophenol ND ug/L 10/21/22 15:42 88-06-210/20/22 14:4110.0 1 Surrogates Nitrobenzene-d5 (S)52 %10/21/22 15:42 4165-60-010/20/22 14:4110-120 1 2-Fluorobiphenyl (S)28 %10/21/22 15:42 321-60-810/20/22 14:4115-120 1 Terphenyl-d14 (S)93 %10/21/22 15:42 1718-51-010/20/22 14:4111-131 1 Phenol-d6 (S)25 %10/21/22 15:42 13127-88-310/20/22 14:4110-120 1 2-Fluorophenol (S)15 %10/21/22 15:42 367-12-410/20/22 14:4110-120 1 2,4,6-Tribromophenol (S)17 %10/21/22 15:42 118-79-610/20/22 14:4110-137 1 Tentatively Identified Compounds Unknown 5.6J ug/L 10/21/22 15:4210/20/22 14:411 Benzenesulfonamide, N-e 5.6J ug/L 10/21/22 15:42 80-39-7 N10/20/22 14:411 Eicosane 6.2J ug/L 10/21/22 15:42 112-95-8 N10/20/22 14:411 Analytical Method: SM 6200B Pace Analytical Services - Charlotte 6200B MSV Benzene ND ug/L 10/25/22 01:20 71-43-20.50 1 Bromobenzene ND ug/L 10/25/22 01:20 108-86-10.50 1 Bromochloromethane ND ug/L 10/25/22 01:20 74-97-50.50 1 Bromodichloromethane ND ug/L 10/25/22 01:20 75-27-40.50 1 Bromoform ND ug/L 10/25/22 01:20 75-25-20.50 1 Bromomethane ND ug/L 10/25/22 01:20 74-83-95.0 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 17 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-3 Lab ID: 92631278006 Collected: 10/13/22 00:00 Received: 10/14/22 10:15 Matrix: Water Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: SM 6200B Pace Analytical Services - Charlotte 6200B MSV n-Butylbenzene ND ug/L 10/25/22 01:20 104-51-80.50 1 sec-Butylbenzene ND ug/L 10/25/22 01:20 135-98-80.50 1 tert-Butylbenzene ND ug/L 10/25/22 01:20 98-06-60.50 1 Carbon tetrachloride ND ug/L 10/25/22 01:20 56-23-50.50 1 Chlorobenzene ND ug/L 10/25/22 01:20 108-90-70.50 1 Chloroethane ND ug/L 10/25/22 01:20 75-00-31.0 1 Chloroform ND ug/L 10/25/22 01:20 67-66-30.50 1 Chloromethane 1.6 ug/L 10/25/22 01:20 74-87-31.0 1 2-Chlorotoluene ND ug/L 10/25/22 01:20 95-49-80.50 1 4-Chlorotoluene ND ug/L 10/25/22 01:20 106-43-40.50 1 1,2-Dibromo-3-chloropropane ND ug/L 10/25/22 01:20 96-12-81.0 1 Dibromochloromethane ND ug/L 10/25/22 01:20 124-48-10.50 1 1,2-Dibromoethane (EDB)ND ug/L 10/25/22 01:20 106-93-40.50 1 Dibromomethane ND ug/L 10/25/22 01:20 74-95-30.50 1 1,2-Dichlorobenzene ND ug/L 10/25/22 01:20 95-50-10.50 1 1,3-Dichlorobenzene ND ug/L 10/25/22 01:20 541-73-10.50 1 1,4-Dichlorobenzene ND ug/L 10/25/22 01:20 106-46-70.50 1 Dichlorodifluoromethane ND ug/L 10/25/22 01:20 75-71-80.50 1 1,1-Dichloroethane ND ug/L 10/25/22 01:20 75-34-30.50 1 1,2-Dichloroethane ND ug/L 10/25/22 01:20 107-06-20.50 1 1,1-Dichloroethene ND ug/L 10/25/22 01:20 75-35-40.50 1 cis-1,2-Dichloroethene ND ug/L 10/25/22 01:20 156-59-20.50 1 trans-1,2-Dichloroethene ND ug/L 10/25/22 01:20 156-60-50.50 1 1,2-Dichloropropane ND ug/L 10/25/22 01:20 78-87-50.50 1 1,3-Dichloropropane ND ug/L 10/25/22 01:20 142-28-90.50 1 2,2-Dichloropropane ND ug/L 10/25/22 01:20 594-20-70.50 1 1,1-Dichloropropene ND ug/L 10/25/22 01:20 563-58-60.50 1 cis-1,3-Dichloropropene ND ug/L 10/25/22 01:20 10061-01-50.50 1 trans-1,3-Dichloropropene ND ug/L 10/25/22 01:20 10061-02-60.50 1 Diisopropyl ether ND ug/L 10/25/22 01:20 108-20-30.50 1 Ethylbenzene ND ug/L 10/25/22 01:20 100-41-40.50 1 Hexachloro-1,3-butadiene ND ug/L 10/25/22 01:20 87-68-32.0 1 Isopropylbenzene (Cumene)ND ug/L 10/25/22 01:20 98-82-80.50 1 Methylene Chloride ND ug/L 10/25/22 01:20 75-09-22.0 1 Methyl-tert-butyl ether ND ug/L 10/25/22 01:20 1634-04-40.50 1 Naphthalene ND ug/L 10/25/22 01:20 91-20-32.0 1 n-Propylbenzene ND ug/L 10/25/22 01:20 103-65-10.50 1 Styrene ND ug/L 10/25/22 01:20 100-42-50.50 1 1,1,1,2-Tetrachloroethane ND ug/L 10/25/22 01:20 630-20-60.50 1 1,1,2,2-Tetrachloroethane ND ug/L 10/25/22 01:20 79-34-50.50 1 Tetrachloroethene ND ug/L 10/25/22 01:20 127-18-40.50 1 Toluene ND ug/L 10/25/22 01:20 108-88-30.50 1 1,2,3-Trichlorobenzene ND ug/L 10/25/22 01:20 87-61-62.0 1 1,2,4-Trichlorobenzene ND ug/L 10/25/22 01:20 120-82-12.0 1 1,1,1-Trichloroethane ND ug/L 10/25/22 01:20 71-55-60.50 1 1,1,2-Trichloroethane ND ug/L 10/25/22 01:20 79-00-50.50 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 18 of 75 #=AR# ANALYTICAL RESULTS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Sample: MW-3 Lab ID: 92631278006 Collected: 10/13/22 00:00 Received: 10/14/22 10:15 Matrix: Water Parameters Results Units DF Prepared Analyzed CAS No. QualReport Limit Analytical Method: SM 6200B Pace Analytical Services - Charlotte 6200B MSV Trichloroethene ND ug/L 10/25/22 01:20 79-01-60.50 1 Trichlorofluoromethane ND ug/L 10/25/22 01:20 75-69-41.0 1 1,2,3-Trichloropropane ND ug/L 10/25/22 01:20 96-18-40.50 1 1,2,4-Trimethylbenzene ND ug/L 10/25/22 01:20 95-63-60.50 1 1,3,5-Trimethylbenzene ND ug/L 10/25/22 01:20 108-67-80.50 1 Vinyl chloride ND ug/L 10/25/22 01:20 75-01-41.0 1 m&p-Xylene ND ug/L 10/25/22 01:20 179601-23-11.0 1 o-Xylene ND ug/L 10/25/22 01:20 95-47-60.50 1 Surrogates 1,2-Dichloroethane-d4 (S)99 %10/25/22 01:20 17060-07-070-130 1 4-Bromofluorobenzene (S)101 %10/25/22 01:20 460-00-470-130 1 Toluene-d8 (S)109 %10/25/22 01:20 2037-26-570-130 1 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 19 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 731297 MADEP VPH MADEP VPH VPH NC Soil Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3807052 Associated Lab Samples:92631278003 Matrix: Solid Analyzed Aliphatic (C05-C08)mg/kg ND 2.5 N210/20/22 23:28 Aromatic (C09-C10)mg/kg ND 2.5 N210/20/22 23:28 4-Bromofluorobenzene (FID) (S)%105 70-130 10/20/22 23:28 4-Bromofluorobenzene (PID) (S)%107 70-130 10/20/22 23:28 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3807053LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 3807054 Aliphatic (C05-C08)mg/kg 13.8 N2159270-1309314.0 2 25 Aromatic (C09-C10)mg/kg 5.6 N2511270-1301125.6 0 25 4-Bromofluorobenzene (FID) (S)%103 70-130101 4-Bromofluorobenzene (PID) (S)%105 70-130103 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 20 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 733579 MADEP VPH MADEP VPH VPH NC Soil Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278001, 92631278002 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3818358 Associated Lab Samples:92631278001, 92631278002 Matrix: Solid Analyzed Aliphatic (C05-C08)mg/kg ND 2.5 N210/28/22 17:36 Aromatic (C09-C10)mg/kg ND 2.5 N210/28/22 17:36 4-Bromofluorobenzene (FID) (S)%98 70-130 10/28/22 17:36 4-Bromofluorobenzene (PID) (S)%86 70-130 10/28/22 17:36 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3818359LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 3818360 Aliphatic (C05-C08)mg/kg 18.0 N21511970-13011717.6 2 25 Aromatic (C09-C10)mg/kg 5.0 N2510170-130994.9 2 25 4-Bromofluorobenzene (FID) (S)%99 70-130102 4-Bromofluorobenzene (PID) (S)%90 70-13092 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 21 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 732879 EPA 3010A EPA 6010D 6010 MET Laboratory:Pace Analytical Services - Asheville Associated Lab Samples: 92631278004, 92631278005, 92631278006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3814428 Associated Lab Samples:92631278004, 92631278005, 92631278006 Matrix: Water Analyzed Lead ug/L ND 5.0 10/27/22 16:41 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3814429LABORATORY CONTROL SAMPLE: LCSSpike Lead ug/L 465500 93 80-120 Parameter Units MS Result % Rec Limits Qual% RecConc. 3814430MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92631257005 3814431 MSD Result MSD % Rec RPD MSDMS Spike Conc. Lead ug/L 500 92 75-12593 1500ND461 465 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 22 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 732223 SM 6200B SM 6200B 6200B MSV Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278004, 92631278006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3811486 Associated Lab Samples:92631278004, 92631278006 Matrix: Water Analyzed 1,1,1,2-Tetrachloroethane ug/L ND 0.50 10/24/22 23:33 1,1,1-Trichloroethane ug/L ND 0.50 10/24/22 23:33 1,1,2,2-Tetrachloroethane ug/L ND 0.50 10/24/22 23:33 1,1,2-Trichloroethane ug/L ND 0.50 10/24/22 23:33 1,1-Dichloroethane ug/L ND 0.50 10/24/22 23:33 1,1-Dichloroethene ug/L ND 0.50 10/24/22 23:33 1,1-Dichloropropene ug/L ND 0.50 10/24/22 23:33 1,2,3-Trichlorobenzene ug/L ND 2.0 10/24/22 23:33 1,2,3-Trichloropropane ug/L ND 0.50 10/24/22 23:33 1,2,4-Trichlorobenzene ug/L ND 2.0 10/24/22 23:33 1,2,4-Trimethylbenzene ug/L ND 0.50 10/24/22 23:33 1,2-Dibromo-3-chloropropane ug/L ND 1.0 10/24/22 23:33 1,2-Dibromoethane (EDB)ug/L ND 0.50 10/24/22 23:33 1,2-Dichlorobenzene ug/L ND 0.50 10/24/22 23:33 1,2-Dichloroethane ug/L ND 0.50 10/24/22 23:33 1,2-Dichloropropane ug/L ND 0.50 10/24/22 23:33 1,3,5-Trimethylbenzene ug/L ND 0.50 10/24/22 23:33 1,3-Dichlorobenzene ug/L ND 0.50 10/24/22 23:33 1,3-Dichloropropane ug/L ND 0.50 10/24/22 23:33 1,4-Dichlorobenzene ug/L ND 0.50 10/24/22 23:33 2,2-Dichloropropane ug/L ND 0.50 10/24/22 23:33 2-Chlorotoluene ug/L ND 0.50 10/24/22 23:33 4-Chlorotoluene ug/L ND 0.50 10/24/22 23:33 Benzene ug/L ND 0.50 10/24/22 23:33 Bromobenzene ug/L ND 0.50 10/24/22 23:33 Bromochloromethane ug/L ND 0.50 10/24/22 23:33 Bromodichloromethane ug/L ND 0.50 10/24/22 23:33 Bromoform ug/L ND 0.50 10/24/22 23:33 Bromomethane ug/L ND 5.0 10/24/22 23:33 Carbon tetrachloride ug/L ND 0.50 10/24/22 23:33 Chlorobenzene ug/L ND 0.50 10/24/22 23:33 Chloroethane ug/L ND 1.0 10/24/22 23:33 Chloroform ug/L ND 0.50 10/24/22 23:33 Chloromethane ug/L ND 1.0 10/24/22 23:33 cis-1,2-Dichloroethene ug/L ND 0.50 10/24/22 23:33 cis-1,3-Dichloropropene ug/L ND 0.50 10/24/22 23:33 Dibromochloromethane ug/L ND 0.50 10/24/22 23:33 Dibromomethane ug/L ND 0.50 10/24/22 23:33 Dichlorodifluoromethane ug/L ND 0.50 10/24/22 23:33 Diisopropyl ether ug/L ND 0.50 10/24/22 23:33 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 23 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3811486 Associated Lab Samples:92631278004, 92631278006 Matrix: Water Analyzed Ethanol ug/L ND 200 10/24/22 23:33 Ethyl-tert-butyl ether ug/L ND 10.0 10/24/22 23:33 Ethylbenzene ug/L ND 0.50 10/24/22 23:33 Hexachloro-1,3-butadiene ug/L ND 2.0 10/24/22 23:33 Isopropylbenzene (Cumene)ug/L ND 0.50 10/24/22 23:33 m&p-Xylene ug/L ND 1.0 10/24/22 23:33 Methyl-tert-butyl ether ug/L ND 0.50 10/24/22 23:33 Methylene Chloride ug/L ND 2.0 10/24/22 23:33 n-Butylbenzene ug/L ND 0.50 10/24/22 23:33 n-Propylbenzene ug/L ND 0.50 10/24/22 23:33 Naphthalene ug/L ND 2.0 10/24/22 23:33 o-Xylene ug/L ND 0.50 10/24/22 23:33 sec-Butylbenzene ug/L ND 0.50 10/24/22 23:33 Styrene ug/L ND 0.50 10/24/22 23:33 tert-Amyl Alcohol ug/L ND 100 10/24/22 23:33 tert-Amylmethyl ether ug/L ND 10.0 10/24/22 23:33 tert-Butyl Alcohol ug/L ND 50.0 10/24/22 23:33 tert-Butyl Formate ug/L ND 50.0 10/24/22 23:33 tert-Butylbenzene ug/L ND 0.50 10/24/22 23:33 Tetrachloroethene ug/L ND 0.50 10/24/22 23:33 Toluene ug/L ND 0.50 10/24/22 23:33 trans-1,2-Dichloroethene ug/L ND 0.50 10/24/22 23:33 trans-1,3-Dichloropropene ug/L ND 0.50 10/24/22 23:33 Trichloroethene ug/L ND 0.50 10/24/22 23:33 Trichlorofluoromethane ug/L ND 1.0 10/24/22 23:33 Vinyl chloride ug/L ND 1.0 10/24/22 23:33 1,2-Dichloroethane-d4 (S)%101 70-130 10/24/22 23:33 4-Bromofluorobenzene (S)%102 70-130 10/24/22 23:33 Toluene-d8 (S)%108 70-130 10/24/22 23:33 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3811487LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1,2-Tetrachloroethane ug/L 49.750 99 60-140 1,1,1-Trichloroethane ug/L 56.450 113 60-140 1,1,2,2-Tetrachloroethane ug/L 47.450 95 60-140 1,1,2-Trichloroethane ug/L 49.750 99 60-140 1,1-Dichloroethane ug/L 51.250 102 60-140 1,1-Dichloroethene ug/L 55.550 111 60-140 1,1-Dichloropropene ug/L 61.150 122 60-140 1,2,3-Trichlorobenzene ug/L 42.650 85 60-140 1,2,3-Trichloropropane ug/L 47.550 95 60-140 1,2,4-Trichlorobenzene ug/L 42.350 85 60-140 1,2,4-Trimethylbenzene ug/L 45.450 91 60-140 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 24 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3811487LABORATORY CONTROL SAMPLE: LCSSpike 1,2-Dibromo-3-chloropropane ug/L 49.750 99 60-140 1,2-Dibromoethane (EDB)ug/L 49.550 99 60-140 1,2-Dichlorobenzene ug/L 43.750 87 60-140 1,2-Dichloroethane ug/L 51.350 103 60-140 1,2-Dichloropropane ug/L 52.650 105 60-140 1,3,5-Trimethylbenzene ug/L 46.950 94 60-140 1,3-Dichlorobenzene ug/L 45.250 90 60-140 1,3-Dichloropropane ug/L 49.750 99 60-140 1,4-Dichlorobenzene ug/L 43.150 86 60-140 2,2-Dichloropropane ug/L 55.450 111 60-140 2-Chlorotoluene ug/L 44.950 90 60-140 4-Chlorotoluene ug/L 45.050 90 60-140 Benzene ug/L 47.150 94 60-140 Bromobenzene ug/L 45.050 90 60-140 Bromochloromethane ug/L 49.750 99 60-140 Bromodichloromethane ug/L 51.350 103 60-140 Bromoform ug/L 53.150 106 60-140 Bromomethane ug/L 49.150 98 60-140 Carbon tetrachloride ug/L 56.450 113 60-140 Chlorobenzene ug/L 45.650 91 60-140 Chloroethane ug/L 52.450 105 60-140 Chloroform ug/L 50.850 102 60-140 Chloromethane ug/L 60.950 122 60-140 cis-1,2-Dichloroethene ug/L 52.250 104 60-140 cis-1,3-Dichloropropene ug/L 54.550 109 60-140 Dibromochloromethane ug/L 52.950 106 60-140 Dibromomethane ug/L 47.550 95 60-140 Dichlorodifluoromethane ug/L 61.950 124 60-140 Diisopropyl ether ug/L 55.250 110 60-140 Ethanol ug/L 19102000 95 60-140 Ethyl-tert-butyl ether ug/L 105100 105 60-140 Ethylbenzene ug/L 46.650 93 60-140 Hexachloro-1,3-butadiene ug/L 42.450 85 60-140 Isopropylbenzene (Cumene)ug/L 46.450 93 60-140 m&p-Xylene ug/L 93.4100 93 60-140 Methyl-tert-butyl ether ug/L 54.950 110 60-140 Methylene Chloride ug/L 53.950 108 60-140 n-Butylbenzene ug/L 48.550 97 60-140 n-Propylbenzene ug/L 46.950 94 60-140 Naphthalene ug/L 46.550 93 60-140 o-Xylene ug/L 46.150 92 60-140 sec-Butylbenzene ug/L 46.850 94 60-140 Styrene ug/L 47.350 95 60-140 tert-Amyl Alcohol ug/L 10701000 107 60-140 tert-Amylmethyl ether ug/L 99.9100 100 60-140 tert-Butyl Alcohol ug/L 440500 88 60-140 tert-Butyl Formate ug/L 379400 95 60-140 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 25 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3811487LABORATORY CONTROL SAMPLE: LCSSpike tert-Butylbenzene ug/L 39.650 79 60-140 Tetrachloroethene ug/L 45.750 91 60-140 Toluene ug/L 45.950 92 60-140 trans-1,2-Dichloroethene ug/L 53.550 107 60-140 trans-1,3-Dichloropropene ug/L 53.250 106 60-140 Trichloroethene ug/L 51.450 103 60-140 Trichlorofluoromethane ug/L 57.550 115 60-140 Vinyl chloride ug/L 63.050 126 60-140 1,2-Dichloroethane-d4 (S)%102 70-130 4-Bromofluorobenzene (S)%103 70-130 Toluene-d8 (S)%99 70-130 Parameter Units MS Result % Rec Limits Qual% RecConc. 3811488MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92631278004 3811489 MSD Result MSD % Rec RPD MSDMS Spike Conc. 1,1,1,2-Tetrachloroethane ug/L 20 113 60-140114 120ND22.7 22.8 1,1,1-Trichloroethane ug/L 20 116 60-140118 220ND23.1 23.6 1,1,2,2-Tetrachloroethane ug/L 20 103 60-140103 020ND20.5 20.5 1,1,2-Trichloroethane ug/L 20 99 60-14099 120ND19.7 19.9 1,1-Dichloroethane ug/L 20 109 60-140112 220ND21.9 22.4 1,1-Dichloroethene ug/L 20 122 60-140120 120ND24.4 24.1 1,1-Dichloropropene ug/L 20 127 60-140130 220ND25.4 26.0 1,2,3-Trichlorobenzene ug/L 20 100 60-14098 220ND20.1 19.6 1,2,3-Trichloropropane ug/L 20 103 60-140104 120ND20.7 20.8 1,2,4-Trichlorobenzene ug/L 20 101 60-14099 220ND20.3 19.9 1,2,4-Trimethylbenzene ug/L 20 111 60-140107 3200.88 23.1 22.3 1,2-Dibromo-3-chloropropane ug/L 20 105 60-140105 120ND21.0 20.9 1,2-Dibromoethane (EDB)ug/L 20 109 60-140109 020ND21.8 21.7 1,2-Dichlorobenzene ug/L 20 102 60-140100 320ND20.5 19.9 1,2-Dichloroethane ug/L 20 108 60-140108 020ND21.5 21.6 1,2-Dichloropropane ug/L 20 107 60-140110 220ND21.5 22.0 1,3,5-Trimethylbenzene ug/L 20 114 60-140111 320ND22.9 22.1 1,3-Dichlorobenzene ug/L 20 107 60-140102 420ND21.4 20.4 1,3-Dichloropropane ug/L 20 110 60-140111 020ND22.0 22.1 1,4-Dichlorobenzene ug/L 20 100 60-14098 220ND20.0 19.6 2,2-Dichloropropane ug/L 20 120 60-140120 020ND24.1 24.0 2-Chlorotoluene ug/L 20 106 60-140103 320ND21.3 20.6 4-Chlorotoluene ug/L 20 109 60-140104 420ND21.8 20.8 Benzene ug/L M1209960-140152 282011.9 31.8 42.2 Bromobenzene ug/L 20 104 60-140102 220ND20.9 20.4 Bromochloromethane ug/L 20 101 60-140102 120ND20.3 20.5 Bromodichloromethane ug/L 20 108 60-140109 020ND21.6 21.7 Bromoform ug/L 20 112 60-140110 120ND22.3 22.0 Bromomethane ug/L 20 102 60-140106 420ND20.5 21.3 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 26 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qual% RecConc. 3811488MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92631278004 3811489 MSD Result MSD % Rec RPD MSDMS Spike Conc. Carbon tetrachloride ug/L 20 112 60-140114 220ND22.4 22.9 Chlorobenzene ug/L 20 103 60-140102 120ND20.7 20.5 Chloroethane ug/L 20 127 60-140126 120ND25.3 25.1 Chloroform ug/L 20 109 60-140109 020ND21.8 21.8 Chloromethane ug/L 20 138 60-140136 120ND27.7 27.3 cis-1,2-Dichloroethene ug/L 20 110 60-140111 120ND21.9 22.1 cis-1,3-Dichloropropene ug/L 20 105 60-140106 020ND21.1 21.1 Dibromochloromethane ug/L 20 109 60-140110 120ND21.8 22.1 Dibromomethane ug/L 20 93 60-14094 220ND18.5 18.9 Dichlorodifluoromethane ug/L 20 136 60-140136 020ND27.2 27.2 Diisopropyl ether ug/L M12012360-140149 15207.6 32.2 37.4 Ethanol ug/L 800 96 60-14097 0800ND771 772 Ethyl-tert-butyl ether ug/L 40 113 60-140113 040ND45.1 45.3 Ethylbenzene ug/L 20 109 60-140116 6202.9 24.7 26.2 Hexachloro-1,3-butadiene ug/L 20 100 60-14097 320ND20.0 19.4 Isopropylbenzene (Cumene) ug/L M12011060-140152 172023.6 45.6 54.0 m&p-Xylene ug/L 40 107 60-140112 4402.3 45.2 46.9 Methyl-tert-butyl ether ug/L 20 119 60-140133 10204.3 28.1 31.0 Methylene Chloride ug/L 20 104 60-140104 020ND20.9 20.8 n-Butylbenzene ug/L 20 124 60-140133 22051.2 75.9 77.8 n-Propylbenzene ug/L M12012360-140253 202095.1 120 146 Naphthalene ug/L M12013360-140197 182038.6 65.2 78.0 o-Xylene ug/L 20 107 60-140104 2200.53 21.9 21.4 sec-Butylbenzene ug/L 20 116 60-140122 22022.3 45.5 46.7 Styrene ug/L 20 106 60-140105 120ND21.2 21.1 tert-Amyl Alcohol ug/L 400 109 60-140117 7400ND436 466 tert-Amylmethyl ether ug/L 40 108 60-140111 340ND43.1 44.3 tert-Butyl Alcohol ug/L 200 94 60-140106 10200ND235 261 tert-Butyl Formate ug/L M11604360-14041 4160ND68.8 66.0 tert-Butylbenzene ug/L 20 94 60-14092 3200.62 19.5 19.0 Tetrachloroethene ug/L 20 109 60-140108 120ND21.8 21.7 Toluene ug/L 20 95 60-14097 3200.51 19.5 19.9 trans-1,2-Dichloroethene ug/L 20 114 60-140115 120ND22.8 23.1 trans-1,3-Dichloropropene ug/L 20 107 60-140108 120ND21.4 21.6 Trichloroethene ug/L 20 104 60-140107 320ND20.8 21.4 Trichlorofluoromethane ug/L 20 132 60-140130 220ND26.5 26.0 Vinyl chloride ug/L 20 136 60-140140 320ND27.2 28.0 1,2-Dichloroethane-d4 (S)%101 70-130100 4-Bromofluorobenzene (S)%106 70-130107 Toluene-d8 (S)%93 70-13092 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 27 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 732655 SM 6200B SM 6200B 6200B MSV Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278005 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3813503 Associated Lab Samples:92631278005 Matrix: Water Analyzed 1,1,1,2-Tetrachloroethane ug/L ND 0.50 10/25/22 13:07 1,1,1-Trichloroethane ug/L ND 0.50 10/25/22 13:07 1,1,2,2-Tetrachloroethane ug/L ND 0.50 10/25/22 13:07 1,1,2-Trichloroethane ug/L ND 0.50 10/25/22 13:07 1,1-Dichloroethane ug/L ND 0.50 10/25/22 13:07 1,1-Dichloroethene ug/L ND 0.50 10/25/22 13:07 1,1-Dichloropropene ug/L ND 0.50 10/25/22 13:07 1,2,3-Trichlorobenzene ug/L ND 2.0 10/25/22 13:07 1,2,3-Trichloropropane ug/L ND 0.50 10/25/22 13:07 1,2,4-Trichlorobenzene ug/L ND 2.0 10/25/22 13:07 1,2,4-Trimethylbenzene ug/L ND 0.50 10/25/22 13:07 1,2-Dibromo-3-chloropropane ug/L ND 1.0 10/25/22 13:07 1,2-Dibromoethane (EDB)ug/L ND 0.50 10/25/22 13:07 1,2-Dichlorobenzene ug/L ND 0.50 10/25/22 13:07 1,2-Dichloroethane ug/L ND 0.50 10/25/22 13:07 1,2-Dichloropropane ug/L ND 0.50 10/25/22 13:07 1,3,5-Trimethylbenzene ug/L ND 0.50 10/25/22 13:07 1,3-Dichlorobenzene ug/L ND 0.50 10/25/22 13:07 1,3-Dichloropropane ug/L ND 0.50 10/25/22 13:07 1,4-Dichlorobenzene ug/L ND 0.50 10/25/22 13:07 2,2-Dichloropropane ug/L ND 0.50 10/25/22 13:07 2-Chlorotoluene ug/L ND 0.50 10/25/22 13:07 4-Chlorotoluene ug/L ND 0.50 10/25/22 13:07 Benzene ug/L ND 0.50 10/25/22 13:07 Bromobenzene ug/L ND 0.50 10/25/22 13:07 Bromochloromethane ug/L ND 0.50 10/25/22 13:07 Bromodichloromethane ug/L ND 0.50 10/25/22 13:07 Bromoform ug/L ND 0.50 10/25/22 13:07 Bromomethane ug/L ND 5.0 10/25/22 13:07 Carbon tetrachloride ug/L ND 0.50 10/25/22 13:07 Chlorobenzene ug/L ND 0.50 10/25/22 13:07 Chloroethane ug/L ND 1.0 10/25/22 13:07 Chloroform ug/L ND 0.50 10/25/22 13:07 Chloromethane ug/L ND 1.0 10/25/22 13:07 cis-1,2-Dichloroethene ug/L ND 0.50 10/25/22 13:07 cis-1,3-Dichloropropene ug/L ND 0.50 10/25/22 13:07 Dibromochloromethane ug/L ND 0.50 10/25/22 13:07 Dibromomethane ug/L ND 0.50 10/25/22 13:07 Dichlorodifluoromethane ug/L ND 0.50 10/25/22 13:07 Diisopropyl ether ug/L ND 0.50 10/25/22 13:07 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 28 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3813503 Associated Lab Samples:92631278005 Matrix: Water Analyzed Ethanol ug/L ND 200 10/25/22 13:07 Ethyl-tert-butyl ether ug/L ND 10.0 10/25/22 13:07 Ethylbenzene ug/L ND 0.50 10/25/22 13:07 Hexachloro-1,3-butadiene ug/L ND 2.0 10/25/22 13:07 Isopropylbenzene (Cumene)ug/L ND 0.50 10/25/22 13:07 m&p-Xylene ug/L ND 1.0 10/25/22 13:07 Methyl-tert-butyl ether ug/L ND 0.50 10/25/22 13:07 Methylene Chloride ug/L ND 2.0 10/25/22 13:07 n-Butylbenzene ug/L ND 0.50 10/25/22 13:07 n-Propylbenzene ug/L ND 0.50 10/25/22 13:07 Naphthalene ug/L ND 2.0 10/25/22 13:07 o-Xylene ug/L ND 0.50 10/25/22 13:07 sec-Butylbenzene ug/L ND 0.50 10/25/22 13:07 Styrene ug/L ND 0.50 10/25/22 13:07 tert-Amyl Alcohol ug/L ND 100 10/25/22 13:07 tert-Amylmethyl ether ug/L ND 10.0 10/25/22 13:07 tert-Butyl Alcohol ug/L ND 50.0 10/25/22 13:07 tert-Butyl Formate ug/L ND 50.0 10/25/22 13:07 tert-Butylbenzene ug/L ND 0.50 10/25/22 13:07 Tetrachloroethene ug/L ND 0.50 10/25/22 13:07 Toluene ug/L ND 0.50 10/25/22 13:07 trans-1,2-Dichloroethene ug/L ND 0.50 10/25/22 13:07 trans-1,3-Dichloropropene ug/L ND 0.50 10/25/22 13:07 Trichloroethene ug/L ND 0.50 10/25/22 13:07 Trichlorofluoromethane ug/L ND 1.0 10/25/22 13:07 Vinyl chloride ug/L ND 1.0 10/25/22 13:07 1,2-Dichloroethane-d4 (S)%103 70-130 10/25/22 13:07 4-Bromofluorobenzene (S)%99 70-130 10/25/22 13:07 Toluene-d8 (S)%103 70-130 10/25/22 13:07 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3813504LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1,2-Tetrachloroethane ug/L 54.350 109 60-140 1,1,1-Trichloroethane ug/L 55.950 112 60-140 1,1,2,2-Tetrachloroethane ug/L 54.150 108 60-140 1,1,2-Trichloroethane ug/L 53.150 106 60-140 1,1-Dichloroethane ug/L 52.650 105 60-140 1,1-Dichloroethene ug/L 56.450 113 60-140 1,1-Dichloropropene ug/L 63.350 127 60-140 1,2,3-Trichlorobenzene ug/L 59.650 119 60-140 1,2,3-Trichloropropane ug/L 52.250 104 60-140 1,2,4-Trichlorobenzene ug/L 58.750 117 60-140 1,2,4-Trimethylbenzene ug/L 52.850 106 60-140 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 29 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3813504LABORATORY CONTROL SAMPLE: LCSSpike 1,2-Dibromo-3-chloropropane ug/L 56.650 113 60-140 1,2-Dibromoethane (EDB)ug/L 55.850 112 60-140 1,2-Dichlorobenzene ug/L 52.750 105 60-140 1,2-Dichloroethane ug/L 53.850 108 60-140 1,2-Dichloropropane ug/L 55.050 110 60-140 1,3,5-Trimethylbenzene ug/L 55.250 110 60-140 1,3-Dichlorobenzene ug/L 53.250 106 60-140 1,3-Dichloropropane ug/L 53.450 107 60-140 1,4-Dichlorobenzene ug/L 51.050 102 60-140 2,2-Dichloropropane ug/L 63.950 128 60-140 2-Chlorotoluene ug/L 53.050 106 60-140 4-Chlorotoluene ug/L 52.950 106 60-140 Benzene ug/L 49.850 100 60-140 Bromobenzene ug/L 50.450 101 60-140 Bromochloromethane ug/L 53.450 107 60-140 Bromodichloromethane ug/L 53.950 108 60-140 Bromoform ug/L 57.750 115 60-140 Bromomethane ug/L 52.350 105 60-140 Carbon tetrachloride ug/L 55.650 111 60-140 Chlorobenzene ug/L 51.150 102 60-140 Chloroethane ug/L 49.950 100 60-140 Chloroform ug/L 52.450 105 60-140 Chloromethane ug/L 62.750 125 60-140 cis-1,2-Dichloroethene ug/L 54.250 108 60-140 cis-1,3-Dichloropropene ug/L 58.950 118 60-140 Dibromochloromethane ug/L 55.650 111 60-140 Dibromomethane ug/L 51.850 104 60-140 Dichlorodifluoromethane ug/L 63.550 127 60-140 Diisopropyl ether ug/L 57.550 115 60-140 Ethanol ug/L 21202000 106 60-140 Ethyl-tert-butyl ether ug/L 107100 107 60-140 Ethylbenzene ug/L 52.450 105 60-140 Hexachloro-1,3-butadiene ug/L 61.950 124 60-140 Isopropylbenzene (Cumene)ug/L 53.950 108 60-140 m&p-Xylene ug/L 108100 108 60-140 Methyl-tert-butyl ether ug/L 57.050 114 60-140 Methylene Chloride ug/L 52.250 104 60-140 n-Butylbenzene ug/L 62.750 125 60-140 n-Propylbenzene ug/L 54.550 109 60-140 Naphthalene ug/L 64.850 130 60-140 o-Xylene ug/L 53.050 106 60-140 sec-Butylbenzene ug/L 56.150 112 60-140 Styrene ug/L 56.750 113 60-140 tert-Amyl Alcohol ug/L 11201000 112 60-140 tert-Amylmethyl ether ug/L 108100 108 60-140 tert-Butyl Alcohol ug/L 558500 112 60-140 tert-Butyl Formate ug/L 412400 103 60-140 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 30 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3813504LABORATORY CONTROL SAMPLE: LCSSpike tert-Butylbenzene ug/L 44.850 90 60-140 Tetrachloroethene ug/L 51.950 104 60-140 Toluene ug/L 49.550 99 60-140 trans-1,2-Dichloroethene ug/L 56.350 113 60-140 trans-1,3-Dichloropropene ug/L 59.250 118 60-140 Trichloroethene ug/L 54.450 109 60-140 Trichlorofluoromethane ug/L 59.150 118 60-140 Vinyl chloride ug/L 65.350 131 60-140 1,2-Dichloroethane-d4 (S)%112 70-130 4-Bromofluorobenzene (S)%103 70-130 Toluene-d8 (S)%100 70-130 Parameter Units MS Result % Rec Limits Qual% RecConc. 3813505MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92631667010 3813506 MSD Result MSD % Rec RPD MSDMS Spike Conc. 1,1,1,2-Tetrachloroethane ug/L 250 133 60-140126 5250ND331 316 1,1,1-Trichloroethane ug/L M125014360-140139 3250ND358 347 1,1,2,2-Tetrachloroethane ug/L 250 129 60-140123 4250ND322 308 1,1,2-Trichloroethane ug/L 250 127 60-140124 2250ND317 310 1,1-Dichloroethane ug/L 250 134 60-140131 2250ND334 327 1,1-Dichloroethene ug/L M125014660-140143 3250ND366 357 1,1-Dichloropropene ug/L M125016260-140156 4250ND405 389 1,2,3-Trichlorobenzene ug/L 250 126 60-140130 4250ND320 332 1,2,3-Trichloropropane ug/L 250 123 60-140117 5250ND308 294 1,2,4-Trichlorobenzene ug/L 250 136 60-140138 1250ND341 344 1,2,4-Trimethylbenzene ug/L 250 136 60-140132 325012.1 353 343 1,2-Dibromo-3-chloropropane ug/L 250 129 60-140123 5250ND322 308 1,2-Dibromoethane (EDB)ug/L 250 132 60-140127 4250ND330 317 1,2-Dichlorobenzene ug/L 250 129 60-140125 3250ND323 312 1,2-Dichloroethane ug/L 250 134 60-140129 4250ND335 322 1,2-Dichloropropane ug/L 250 137 60-140136 1250ND343 340 1,3,5-Trimethylbenzene ug/L 250 140 60-140137 3250ND351 342 1,3-Dichlorobenzene ug/L 250 131 60-140129 2250ND328 322 1,3-Dichloropropane ug/L 250 131 60-140125 4250ND328 314 1,4-Dichlorobenzene ug/L 250 128 60-140125 2250ND321 313 2,2-Dichloropropane ug/L M125016160-140157 3250ND402 392 2-Chlorotoluene ug/L 250 136 60-140132 3250ND340 331 4-Chlorotoluene ug/L 250 135 60-140131 3250ND337 327 Benzene ug/L 250 135 60-140131 2250192529 520 Bromobenzene ug/L 250 127 60-140125 1250ND317 313 Bromochloromethane ug/L 250 132 60-140127 3250ND329 318 Bromodichloromethane ug/L 250 134 60-140130 3250ND334 325 Bromoform ug/L 250 131 60-140124 5250ND328 311 Bromomethane ug/L M125014760-140158 7250ND366 394 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 31 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qual% RecConc. 3813505MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92631667010 3813506 MSD Result MSD % Rec RPD MSDMS Spike Conc. Carbon tetrachloride ug/L M125014460-140142 2250ND360 354 Chlorobenzene ug/L 250 128 60-140124 4250ND321 309 Chloroethane ug/L M125016260-140156 4250ND406 391 Chloroform ug/L 250 127 60-140128 1250ND317 320 Chloromethane ug/L M125017660-140174 1250ND439 434 cis-1,2-Dichloroethene ug/L 250 137 60-140131 5250ND342 327 cis-1,3-Dichloropropene ug/L 250 138 60-140135 2250ND346 338 Dibromochloromethane ug/L 250 129 60-140126 3250ND324 314 Dibromomethane ug/L 250 125 60-140123 2250ND312 307 Dichlorodifluoromethane ug/L M125016660-140159 4250ND415 397 Diisopropyl ether ug/L 250 136 60-140132 22508.6 348 340 Ethanol ug/L 10000 127 60-140122 410000ND12700 12200 Ethyl-tert-butyl ether ug/L 500 124 60-140119 4500ND622 595 Ethylbenzene ug/L 250 137 60-140134 2250148492 484 Hexachloro-1,3-butadiene ug/L M125015460-140153 0250ND384 383 Isopropylbenzene (Cumene) ug/L 250 137 60-140131 425015.5 358 344 m&p-Xylene ug/L 500 136 60-140131 4500ND681 655 Methyl-tert-butyl ether ug/L E,M125025360-140235 225019502580 2530 Methylene Chloride ug/L 250 136 60-140133 3250ND341 331 n-Butylbenzene ug/L M125016260-140160 1250ND405 400 n-Propylbenzene ug/L M125014260-140139 225031.3 386 378 Naphthalene ug/L M125013660-140142 325053.4 394 407 o-Xylene ug/L 250 132 60-140127 4250ND329 316 sec-Butylbenzene ug/L M125014660-140142 22507.6 372 364 Styrene ug/L 250 138 60-140132 4250ND344 331 tert-Amyl Alcohol ug/L 5000 130 60-140122 55000904J7390 7020 tert-Amylmethyl ether ug/L 500 125 60-140121 3500ND654 637 tert-Butyl Alcohol ug/L 2500 128 60-140122 52500ND3440 3280 tert-Butyl Formate ug/L 2000 115 60-140110 42000ND2300 2200 tert-Butylbenzene ug/L 250 117 60-140114 2250ND291 284 Tetrachloroethene ug/L 250 131 60-140127 3250ND328 318 Toluene ug/L 250 127 60-140125 2250ND317 311 trans-1,2-Dichloroethene ug/L M125014460-140140 3250ND359 350 trans-1,3-Dichloropropene ug/L 250 137 60-140136 1250ND343 339 Trichloroethene ug/L 250 138 60-140135 2250ND345 337 Trichlorofluoromethane ug/L M125015460-140151 2250ND386 377 Vinyl chloride ug/L M125017160-140167 2250ND428 418 1,2-Dichloroethane-d4 (S)%106 70-130105 4-Bromofluorobenzene (S)%101 70-130101 Toluene-d8 (S)%99 70-130101 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 32 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 731067 EPA 5035A/5030B EPA 8260D 8260D 5035A 5030B Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278001, 92631278002, 92631278003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3806248 Associated Lab Samples:92631278001, 92631278002, 92631278003 Matrix: Solid Analyzed 1,1,1,2-Tetrachloroethane ug/kg ND 5.0 10/18/22 16:58 1,1,1-Trichloroethane ug/kg ND 5.0 10/18/22 16:58 1,1,2,2-Tetrachloroethane ug/kg ND 5.0 10/18/22 16:58 1,1,2-Trichloroethane ug/kg ND 5.0 10/18/22 16:58 1,1-Dichloroethane ug/kg ND 5.0 10/18/22 16:58 1,1-Dichloroethene ug/kg ND 5.0 10/18/22 16:58 1,1-Dichloropropene ug/kg ND 5.0 10/18/22 16:58 1,2,3-Trichlorobenzene ug/kg ND 5.0 10/18/22 16:58 1,2,3-Trichloropropane ug/kg ND 5.0 10/18/22 16:58 1,2,4-Trichlorobenzene ug/kg ND 5.0 10/18/22 16:58 1,2,4-Trimethylbenzene ug/kg ND 5.0 10/18/22 16:58 1,2-Dibromo-3-chloropropane ug/kg ND 5.0 10/18/22 16:58 1,2-Dibromoethane (EDB)ug/kg ND 5.0 10/18/22 16:58 1,2-Dichlorobenzene ug/kg ND 5.0 10/18/22 16:58 1,2-Dichloroethane ug/kg ND 5.0 10/18/22 16:58 1,2-Dichloropropane ug/kg ND 5.0 10/18/22 16:58 1,3,5-Trimethylbenzene ug/kg ND 5.0 10/18/22 16:58 1,3-Dichlorobenzene ug/kg ND 5.0 10/18/22 16:58 1,3-Dichloropropane ug/kg ND 5.0 10/18/22 16:58 1,4-Dichlorobenzene ug/kg ND 5.0 10/18/22 16:58 2,2-Dichloropropane ug/kg ND 5.0 10/18/22 16:58 2-Butanone (MEK)ug/kg ND 100 10/18/22 16:58 2-Chlorotoluene ug/kg ND 5.0 10/18/22 16:58 2-Hexanone ug/kg ND 50.0 10/18/22 16:58 4-Chlorotoluene ug/kg ND 5.0 10/18/22 16:58 4-Methyl-2-pentanone (MIBK)ug/kg ND 50.0 10/18/22 16:58 Acetone ug/kg ND 100 10/18/22 16:58 Benzene ug/kg ND 5.0 10/18/22 16:58 Bromobenzene ug/kg ND 5.0 10/18/22 16:58 Bromochloromethane ug/kg ND 5.0 10/18/22 16:58 Bromodichloromethane ug/kg ND 5.0 10/18/22 16:58 Bromoform ug/kg ND 5.0 10/18/22 16:58 Bromomethane ug/kg ND 10.0 10/18/22 16:58 Carbon tetrachloride ug/kg ND 5.0 v210/18/22 16:58 Chlorobenzene ug/kg ND 5.0 10/18/22 16:58 Chloroethane ug/kg ND 10.0 10/18/22 16:58 Chloroform ug/kg ND 5.0 10/18/22 16:58 Chloromethane ug/kg ND 10.0 10/18/22 16:58 cis-1,2-Dichloroethene ug/kg ND 5.0 10/18/22 16:58 cis-1,3-Dichloropropene ug/kg ND 5.0 10/18/22 16:58 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 33 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3806248 Associated Lab Samples:92631278001, 92631278002, 92631278003 Matrix: Solid Analyzed Dibromochloromethane ug/kg ND 5.0 10/18/22 16:58 Dibromomethane ug/kg ND 5.0 10/18/22 16:58 Dichlorodifluoromethane ug/kg ND 10.0 10/18/22 16:58 Diisopropyl ether ug/kg ND 5.0 10/18/22 16:58 Ethylbenzene ug/kg ND 5.0 10/18/22 16:58 Hexachloro-1,3-butadiene ug/kg ND 10.0 10/18/22 16:58 Isopropylbenzene (Cumene)ug/kg ND 5.0 10/18/22 16:58 m&p-Xylene ug/kg ND 10.0 10/18/22 16:58 Methyl-tert-butyl ether ug/kg ND 5.0 10/18/22 16:58 Methylene Chloride ug/kg ND 20.0 10/18/22 16:58 n-Butylbenzene ug/kg ND 5.0 10/18/22 16:58 n-Propylbenzene ug/kg ND 5.0 10/18/22 16:58 Naphthalene ug/kg ND 5.0 10/18/22 16:58 o-Xylene ug/kg ND 5.0 10/18/22 16:58 p-Isopropyltoluene ug/kg ND 5.0 10/18/22 16:58 sec-Butylbenzene ug/kg ND 5.0 10/18/22 16:58 Styrene ug/kg ND 5.0 10/18/22 16:58 tert-Butylbenzene ug/kg ND 5.0 10/18/22 16:58 Tetrachloroethene ug/kg ND 5.0 10/18/22 16:58 Toluene ug/kg ND 5.0 10/18/22 16:58 trans-1,2-Dichloroethene ug/kg ND 5.0 10/18/22 16:58 trans-1,3-Dichloropropene ug/kg ND 5.0 10/18/22 16:58 Trichloroethene ug/kg ND 5.0 10/18/22 16:58 Trichlorofluoromethane ug/kg ND 5.0 10/18/22 16:58 Vinyl acetate ug/kg ND 50.0 10/18/22 16:58 Vinyl chloride ug/kg ND 10.0 10/18/22 16:58 Xylene (Total)ug/kg ND 10.0 10/18/22 16:58 1,2-Dichloroethane-d4 (S)%99 70-130 10/18/22 16:58 4-Bromofluorobenzene (S)%98 70-130 10/18/22 16:58 Toluene-d8 (S)%100 70-130 10/18/22 16:58 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3806249LABORATORY CONTROL SAMPLE: LCSSpike 1,1,1,2-Tetrachloroethane ug/kg 11301250 90 70-130 1,1,1-Trichloroethane ug/kg 10601250 85 70-130 1,1,2,2-Tetrachloroethane ug/kg 12501250 100 70-130 1,1,2-Trichloroethane ug/kg 11501250 92 70-130 1,1-Dichloroethane ug/kg 10801250 86 70-130 1,1-Dichloroethene ug/kg 11401250 91 70-130 1,1-Dichloropropene ug/kg 11301250 90 70-130 1,2,3-Trichlorobenzene ug/kg 14701250 117 70-130 1,2,3-Trichloropropane ug/kg 11701250 94 70-130 1,2,4-Trichlorobenzene ug/kg 13301250 107 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 34 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3806249LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trimethylbenzene ug/kg 11501250 92 70-130 1,2-Dibromo-3-chloropropane ug/kg 13001250 104 67-130 1,2-Dibromoethane (EDB)ug/kg 11801250 95 70-130 1,2-Dichlorobenzene ug/kg 12201250 97 70-130 1,2-Dichloroethane ug/kg 11301250 91 70-130 1,2-Dichloropropane ug/kg 11501250 92 70-130 1,3,5-Trimethylbenzene ug/kg 11301250 91 70-130 1,3-Dichlorobenzene ug/kg 11801250 94 70-130 1,3-Dichloropropane ug/kg 11301250 91 70-130 1,4-Dichlorobenzene ug/kg 11101250 89 70-130 2,2-Dichloropropane ug/kg 10201250 81 67-130 2-Butanone (MEK)ug/kg 24902500 100 66-130 2-Chlorotoluene ug/kg 11301250 91 70-130 2-Hexanone ug/kg 25802500 103 70-130 4-Chlorotoluene ug/kg 11301250 91 70-130 4-Methyl-2-pentanone (MIBK)ug/kg 26002500 104 70-130 Acetone ug/kg 24102500 97 67-130 Benzene ug/kg 10701250 86 70-130 Bromobenzene ug/kg 11501250 92 70-130 Bromochloromethane ug/kg 11401250 91 70-130 Bromodichloromethane ug/kg 11701250 93 70-130 Bromoform ug/kg 12501250 100 70-130 Bromomethane ug/kg 12001250 96 53-175 Carbon tetrachloride ug/kg 975 v3125078 70-130 Chlorobenzene ug/kg 11201250 90 70-130 Chloroethane ug/kg 12001250 96 70-135 Chloroform ug/kg 10701250 86 70-130 Chloromethane ug/kg 12601250 101 64-130 cis-1,2-Dichloroethene ug/kg 11501250 92 70-130 cis-1,3-Dichloropropene ug/kg 11701250 93 70-130 Dibromochloromethane ug/kg 11501250 92 70-130 Dibromomethane ug/kg 11601250 93 70-130 Dichlorodifluoromethane ug/kg 12801250 102 63-145 Diisopropyl ether ug/kg 11701250 94 68-130 Ethylbenzene ug/kg 10701250 86 70-130 Hexachloro-1,3-butadiene ug/kg 12101250 97 70-130 Isopropylbenzene (Cumene)ug/kg 10801250 86 70-130 m&p-Xylene ug/kg 22402500 90 70-130 Methyl-tert-butyl ether ug/kg 11101250 89 70-130 Methylene Chloride ug/kg 11101250 88 67-130 n-Butylbenzene ug/kg 11301250 90 70-130 n-Propylbenzene ug/kg 10901250 87 70-130 Naphthalene ug/kg 14901250 119 70-130 o-Xylene ug/kg 11201250 89 70-130 p-Isopropyltoluene ug/kg 11501250 92 70-130 sec-Butylbenzene ug/kg 11301250 91 70-130 Styrene ug/kg 11901250 95 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 35 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3806249LABORATORY CONTROL SAMPLE: LCSSpike tert-Butylbenzene ug/kg 10701250 86 64-130 Tetrachloroethene ug/kg 10601250 85 70-130 Toluene ug/kg 10801250 86 70-130 trans-1,2-Dichloroethene ug/kg 11201250 90 70-130 trans-1,3-Dichloropropene ug/kg 11701250 94 70-130 Trichloroethene ug/kg 11101250 89 70-130 Trichlorofluoromethane ug/kg 10501250 84 70-130 Vinyl acetate ug/kg 24702500 99 70-134 Vinyl chloride ug/kg 12901250 103 68-130 Xylene (Total)ug/kg 33603750 90 70-130 1,2-Dichloroethane-d4 (S)%101 70-130 4-Bromofluorobenzene (S)%98 70-130 Toluene-d8 (S)%100 70-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3806250MATRIX SPIKE SAMPLE: MSSpike Result 92631257004 1,1,1,2-Tetrachloroethane ug/kg 577649 89 58-140ND 1,1,1-Trichloroethane ug/kg 641649 99 58-144ND 1,1,2,2-Tetrachloroethane ug/kg 1110 M1649171 52-139ND 1,1,2-Trichloroethane ug/kg 791649 122 56-140ND 1,1-Dichloroethane ug/kg 744649 115 58-145ND 1,1-Dichloroethene ug/kg 780649 120 57-158ND 1,1-Dichloropropene ug/kg 735649 113 58-151ND 1,2,3-Trichlorobenzene ug/kg ND M16490 48-149ND 1,2,3-Trichloropropane ug/kg 674649 104 54-132ND 1,2,4-Trichlorobenzene ug/kg 724649 112 51-151ND 1,2,4-Trimethylbenzene ug/kg 849649 131 38-170ND 1,2-Dibromo-3-chloropropane ug/kg 483649 74 44-134ND 1,2-Dibromoethane (EDB)ug/kg 712649 110 60-138ND 1,2-Dichlorobenzene ug/kg 761649 117 59-147ND 1,2-Dichloroethane ug/kg 745649 115 57-139ND 1,2-Dichloropropane ug/kg 739649 114 62-145ND 1,3,5-Trimethylbenzene ug/kg 802649 124 47-159ND 1,3-Dichlorobenzene ug/kg 745649 115 58-144ND 1,3-Dichloropropane ug/kg 740649 114 60-142ND 1,4-Dichlorobenzene ug/kg 665649 103 57-143ND 2,2-Dichloropropane ug/kg 607649 93 37-144ND 2-Butanone (MEK)ug/kg 2300 M11300177 28-146ND 2-Chlorotoluene ug/kg 727649 112 55-158ND 2-Hexanone ug/kg 15201300 117 44-141ND 4-Chlorotoluene ug/kg 720649 111 55-146ND 4-Methyl-2-pentanone (MIBK)ug/kg 16901300 105 50-138319 Acetone ug/kg 12801300 99 20-136ND Benzene ug/kg 695649 104 60-14521.8 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 36 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3806250MATRIX SPIKE SAMPLE: MSSpike Result 92631257004 Bromobenzene ug/kg 704649 108 59-145ND Bromochloromethane ug/kg 744649 115 57-143ND Bromodichloromethane ug/kg 605649 93 53-133ND Bromoform ug/kg 473649 73 48-133ND Bromomethane ug/kg 356649 55 10-167ND Carbon tetrachloride ug/kg 440 v364968 57-147ND Chlorobenzene ug/kg 733649 111 61-14411.2 Chloroethane ug/kg 268649 41 10-153ND Chloroform ug/kg 731649 113 58-141ND Chloromethane ug/kg 893649 138 54-165ND cis-1,2-Dichloroethene ug/kg 782649 120 59-144ND cis-1,3-Dichloropropene ug/kg 637649 98 56-137ND Dibromochloromethane ug/kg 509649 78 53-139ND Dibromomethane ug/kg 669649 103 60-136ND Dichlorodifluoromethane ug/kg 830649 128 49-177ND Diisopropyl ether ug/kg 773649 119 53-136ND Ethylbenzene ug/kg 921649 109 53-150215 Hexachloro-1,3-butadiene ug/kg 608649 94 42-186ND Isopropylbenzene (Cumene)ug/kg 807649 116 62-15453.2 m&p-Xylene ug/kg 15501300 113 49-15685.7 Methyl-tert-butyl ether ug/kg 754649 112 54-13327.3 Methylene Chloride ug/kg 787649 117 50-153ND n-Butylbenzene ug/kg 1060649 131 44-174212 n-Propylbenzene ug/kg 867649 115 52-157119 Naphthalene ug/kg 1010 M1649155 37-150ND o-Xylene ug/kg 759649 113 54-15026.7 p-Isopropyltoluene ug/kg 874649 135 50-164ND sec-Butylbenzene ug/kg 1390649 131 58-161536 Styrene ug/kg 747649 115 60-148ND tert-Butylbenzene ug/kg 818649 126 44-151ND Tetrachloroethene ug/kg 658649 101 53-151ND Toluene ug/kg 680649 102 52-14817.6 trans-1,2-Dichloroethene ug/kg 758649 117 60-148ND trans-1,3-Dichloropropene ug/kg 632649 97 55-133ND Trichloroethene ug/kg 676649 104 60-148ND Trichlorofluoromethane ug/kg 407649 63 10-154ND Vinyl acetate ug/kg 14001300 108 50-149ND Vinyl chloride ug/kg 840649 129 57-157ND Xylene (Total)ug/kg 23101950 113 52-153112 1,2-Dichloroethane-d4 (S)%104 70-130 4-Bromofluorobenzene (S)%118 70-130 Toluene-d8 (S)%97 70-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 37 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result QualifiersRPDResult 92631278001 3806251SAMPLE DUPLICATE: 1,1,1,2-Tetrachloroethane ug/kg NDND 1,1,1-Trichloroethane ug/kg NDND 1,1,2,2-Tetrachloroethane ug/kg NDND 1,1,2-Trichloroethane ug/kg NDND 1,1-Dichloroethane ug/kg NDND 1,1-Dichloroethene ug/kg NDND 1,1-Dichloropropene ug/kg NDND 1,2,3-Trichlorobenzene ug/kg NDND 1,2,3-Trichloropropane ug/kg NDND 1,2,4-Trichlorobenzene ug/kg NDND 1,2,4-Trimethylbenzene ug/kg 190 1189 1,2-Dibromo-3-chloropropane ug/kg NDND 1,2-Dibromoethane (EDB)ug/kg NDND 1,2-Dichlorobenzene ug/kg NDND 1,2-Dichloroethane ug/kg NDND 1,2-Dichloropropane ug/kg NDND 1,3,5-Trimethylbenzene ug/kg 94.6 293.1 1,3-Dichlorobenzene ug/kg NDND 1,3-Dichloropropane ug/kg NDND 1,4-Dichlorobenzene ug/kg NDND 2,2-Dichloropropane ug/kg NDND 2-Butanone (MEK)ug/kg NDND 2-Chlorotoluene ug/kg NDND 2-Hexanone ug/kg NDND 4-Chlorotoluene ug/kg NDND 4-Methyl-2-pentanone (MIBK)ug/kg NDND Acetone ug/kg NDND Benzene ug/kg 17.3 616.3 Bromobenzene ug/kg NDND Bromochloromethane ug/kg NDND Bromodichloromethane ug/kg NDND Bromoform ug/kg NDND Bromomethane ug/kg NDND Carbon tetrachloride ug/kg ND v2ND Chlorobenzene ug/kg 3.8JND Chloroethane ug/kg NDND Chloroform ug/kg NDND Chloromethane ug/kg NDND cis-1,2-Dichloroethene ug/kg NDND cis-1,3-Dichloropropene ug/kg NDND Dibromochloromethane ug/kg NDND Dibromomethane ug/kg NDND Dichlorodifluoromethane ug/kg NDND Diisopropyl ether ug/kg 6.4JND Ethylbenzene ug/kg 5JND Hexachloro-1,3-butadiene ug/kg NDND Isopropylbenzene (Cumene)ug/kg 3.9JND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 38 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result QualifiersRPDResult 92631278001 3806251SAMPLE DUPLICATE: m&p-Xylene ug/kg 124 2126 Methyl-tert-butyl ether ug/kg 18.6 519.6 Methylene Chloride ug/kg NDND n-Butylbenzene ug/kg ND21.4 n-Propylbenzene ug/kg NDND Naphthalene ug/kg 17.0 C8ND o-Xylene ug/kg 25.3 727.1 p-Isopropyltoluene ug/kg NDND sec-Butylbenzene ug/kg NDND Styrene ug/kg NDND tert-Butylbenzene ug/kg NDND Tetrachloroethene ug/kg NDND Toluene ug/kg 4.6JND trans-1,2-Dichloroethene ug/kg NDND trans-1,3-Dichloropropene ug/kg NDND Trichloroethene ug/kg NDND Trichlorofluoromethane ug/kg NDND Vinyl acetate ug/kg NDND Vinyl chloride ug/kg NDND Xylene (Total)ug/kg 150 2154 1,2-Dichloroethane-d4 (S)%103101 4-Bromofluorobenzene (S)%100102 Toluene-d8 (S)%101100 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 39 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 732287 EPA 504.1 EPA 504.1 GCS 504 EDB DBCP Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278004, 92631278005, 92631278006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3811648 Associated Lab Samples:92631278004, 92631278005, 92631278006 Matrix: Water Analyzed 1,2,3-Trichloropropane ug/L ND 0.050 10/24/22 19:34 1,2-Dibromo-3-chloropropane ug/L ND 0.050 10/24/22 19:34 1,2-Dibromoethane (EDB)ug/L ND 0.020 10/24/22 19:34 1-Chloro-2-bromopropane (S)%109 70-130 10/24/22 19:34 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3811649LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 3811650 1,2,3-Trichloropropane ug/L 0.270.25 110 70-1301090.27 1 20 1,2-Dibromo-3-chloropropane ug/L 0.250.25 100 70-1301030.26 3 20 1,2-Dibromoethane (EDB)ug/L 0.230.25 94 70-130970.24 2 20 1-Chloro-2-bromopropane (S)%111 70-130112 Parameter Units MS Result % Rec Limits Qual% RecConc. 3811652MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 92632102002 3811653 MSD Result MSD % Rec RPD MSDMS Spike Conc. 1,2,3-Trichloropropane ug/L M1,R10.25 121 65-13544 940.25ND 0.30 0.11 1,2-Dibromo-3-chloropropane ug/L 0.25 102 65-13597 40.25ND 0.25 0.24 1,2-Dibromoethane (EDB)ug/L 0.25 88 65-13586 20.25ND 0.22 0.22 1-Chloro-2-bromopropane (S) %105 70-130104 Parameter Units Dup Result QualifiersRPDResult 92632102001 3811651SAMPLE DUPLICATE: 1,2,3-Trichloropropane ug/L NDND 1,2-Dibromo-3-chloropropane ug/L NDND 1,2-Dibromoethane (EDB)ug/L NDND 1-Chloro-2-bromopropane (S)%111113 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 40 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 731589 EPA 625.1 EPA 625.1 625 MSS Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3808536 Associated Lab Samples:92631278006 Matrix: Water Analyzed 1,2,4-Trichlorobenzene ug/L ND 5.0 10/20/22 18:05 2,4,6-Trichlorophenol ug/L ND 10.0 10/20/22 18:05 2,4-Dichlorophenol ug/L ND 5.0 10/20/22 18:05 2,4-Dimethylphenol ug/L ND 10.0 10/20/22 18:05 2,4-Dinitrophenol ug/L ND 50.0 10/20/22 18:05 2,4-Dinitrotoluene ug/L ND 5.0 10/20/22 18:05 2,6-Dinitrotoluene ug/L ND 5.0 10/20/22 18:05 2-Chloronaphthalene ug/L ND 5.0 10/20/22 18:05 2-Chlorophenol ug/L ND 5.0 10/20/22 18:05 2-Nitrophenol ug/L ND 5.0 10/20/22 18:05 3,3'-Dichlorobenzidine ug/L ND 10.0 10/20/22 18:05 4,6-Dinitro-2-methylphenol ug/L ND 10.0 10/20/22 18:05 4-Bromophenylphenyl ether ug/L ND 5.0 10/20/22 18:05 4-Chloro-3-methylphenol ug/L ND 5.0 10/20/22 18:05 4-Chlorophenylphenyl ether ug/L ND 5.0 10/20/22 18:05 4-Nitrophenol ug/L ND 10.0 10/20/22 18:05 Acenaphthene ug/L ND 5.0 10/20/22 18:05 Acenaphthylene ug/L ND 5.0 10/20/22 18:05 Anthracene ug/L ND 5.0 10/20/22 18:05 Benzo(a)anthracene ug/L ND 5.0 10/20/22 18:05 Benzo(a)pyrene ug/L ND 5.0 10/20/22 18:05 Benzo(b)fluoranthene ug/L ND 5.0 10/20/22 18:05 Benzo(g,h,i)perylene ug/L ND 5.0 10/20/22 18:05 Benzo(k)fluoranthene ug/L ND 5.0 10/20/22 18:05 bis(2-Chloroethoxy)methane ug/L ND 10.0 10/20/22 18:05 bis(2-Chloroethyl) ether ug/L ND 5.0 10/20/22 18:05 bis(2-Ethylhexyl)phthalate ug/L ND 5.0 10/20/22 18:05 Butylbenzylphthalate ug/L ND 5.0 10/20/22 18:05 Chrysene ug/L ND 5.0 10/20/22 18:05 Di-n-butylphthalate ug/L ND 5.0 10/20/22 18:05 Di-n-octylphthalate ug/L ND 5.0 10/20/22 18:05 Dibenz(a,h)anthracene ug/L ND 5.0 10/20/22 18:05 Diethylphthalate ug/L ND 5.0 10/20/22 18:05 Dimethylphthalate ug/L ND 5.0 10/20/22 18:05 Fluoranthene ug/L ND 5.0 10/20/22 18:05 Fluorene ug/L ND 5.0 10/20/22 18:05 Hexachloro-1,3-butadiene ug/L ND 5.0 10/20/22 18:05 Hexachlorobenzene ug/L ND 5.0 10/20/22 18:05 Hexachlorocyclopentadiene ug/L ND 10.0 10/20/22 18:05 Hexachloroethane ug/L ND 5.0 10/20/22 18:05 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 41 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3808536 Associated Lab Samples:92631278006 Matrix: Water Analyzed Indeno(1,2,3-cd)pyrene ug/L ND 5.0 10/20/22 18:05 Isophorone ug/L ND 10.0 10/20/22 18:05 N-Nitroso-di-n-propylamine ug/L ND 5.0 10/20/22 18:05 N-Nitrosodimethylamine ug/L ND 5.0 10/20/22 18:05 N-Nitrosodiphenylamine ug/L ND 10.0 10/20/22 18:05 Naphthalene ug/L ND 5.0 10/20/22 18:05 Nitrobenzene ug/L ND 5.0 10/20/22 18:05 Pentachlorophenol ug/L ND 10.0 10/20/22 18:05 Phenanthrene ug/L ND 5.0 10/20/22 18:05 Phenol ug/L ND 5.0 10/20/22 18:05 Pyrene ug/L ND 5.0 10/20/22 18:05 2,4,6-Tribromophenol (S)%107 10-137 10/20/22 18:05 2-Fluorobiphenyl (S)%73 15-120 10/20/22 18:05 2-Fluorophenol (S)%73 10-120 10/20/22 18:05 Nitrobenzene-d5 (S)%101 10-120 10/20/22 18:05 Phenol-d6 (S)%57 10-120 10/20/22 18:05 Terphenyl-d14 (S)%116 11-131 10/20/22 18:05 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3808537LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trichlorobenzene ug/L 42.050 84 44-142 2,4,6-Trichlorophenol ug/L 46.050 92 37-144 2,4-Dichlorophenol ug/L 47.750 95 1-191 2,4-Dimethylphenol ug/L 63.3 L150127 32-119 2,4-Dinitrophenol ug/L 161250 64 1-181 2,4-Dinitrotoluene ug/L 61.250 122 39-139 2,6-Dinitrotoluene ug/L 57.450 115 50-158 2-Chloronaphthalene ug/L 47.850 96 60-118 2-Chlorophenol ug/L 43.050 86 23-134 2-Nitrophenol ug/L 51.750 103 29-182 3,3'-Dichlorobenzidine ug/L 110100 110 1-262 4,6-Dinitro-2-methylphenol ug/L 93.2100 93 1-181 4-Bromophenylphenyl ether ug/L 46.350 93 53-127 4-Chloro-3-methylphenol ug/L 99.9100 100 22-147 4-Chlorophenylphenyl ether ug/L 48.250 96 25-158 4-Nitrophenol ug/L 128250 51 1-132 Acenaphthene ug/L 47.650 95 47-145 Acenaphthylene ug/L 46.750 93 33-145 Anthracene ug/L 43.150 86 1-166 Benzo(a)anthracene ug/L 48.250 96 33-143 Benzo(a)pyrene ug/L 50.050 100 17-163 Benzo(b)fluoranthene ug/L 50.750 101 24-159 Benzo(g,h,i)perylene ug/L 54.050 108 1-219 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 42 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3808537LABORATORY CONTROL SAMPLE: LCSSpike Benzo(k)fluoranthene ug/L 48.450 97 11-162 bis(2-Chloroethoxy)methane ug/L 47.550 95 33-184 bis(2-Chloroethyl) ether ug/L 44.850 90 12-158 bis(2-Ethylhexyl)phthalate ug/L 56.550 113 8-158 Butylbenzylphthalate ug/L 57.950 116 1-152 Chrysene ug/L 47.750 95 17-168 Di-n-butylphthalate ug/L 57.350 115 1-118 Di-n-octylphthalate ug/L 64.950 130 4-146 Dibenz(a,h)anthracene ug/L 52.850 106 1-227 Diethylphthalate ug/L 54.350 109 1-114 Dimethylphthalate ug/L 51.750 103 1-112 Fluoranthene ug/L 54.350 109 26-137 Fluorene ug/L 49.350 99 59-121 Hexachloro-1,3-butadiene ug/L 38.150 76 24-116 Hexachlorobenzene ug/L 45.950 92 1-152 Hexachlorocyclopentadiene ug/L 47.150 94 25-150 Hexachloroethane ug/L 36.050 72 40-113 Indeno(1,2,3-cd)pyrene ug/L 55.450 111 1-171 Isophorone ug/L 49.650 99 21-196 N-Nitroso-di-n-propylamine ug/L 49.450 99 1-230 N-Nitrosodimethylamine ug/L 41.550 83 25-150 N-Nitrosodiphenylamine ug/L 47.850 96 25-150 Naphthalene ug/L 42.150 84 21-133 Nitrobenzene ug/L 50.450 101 35-180 Pentachlorophenol ug/L 66.4100 66 14-176 Phenanthrene ug/L 48.450 97 54-120 Phenol ug/L 30.650 61 5-112 Pyrene ug/L 44.150 88 52-115 2,4,6-Tribromophenol (S)%99 10-137 2-Fluorobiphenyl (S)%91 15-120 2-Fluorophenol (S)%69 10-120 Nitrobenzene-d5 (S)%102 10-120 Phenol-d6 (S)%59 10-120 Terphenyl-d14 (S)%98 11-131 Parameter Units MS Result % Rec Limits Qual% RecConc. 3808538MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 35753351001 3808539 MSD Result MSD % Rec RPD MSDMS Spike Conc. 1,2,4-Trichlorobenzene ug/L M1501744-14219 14501.7U 8.5 9.7 2,4,6-Trichlorophenol ug/L 50 73 37-14484 15501.6U 36.4 42.1 2,4-Dichlorophenol ug/L 50 66 1-19176 15501.4U 32.8 38.2 2,4-Dimethylphenol ug/L 50 97 32-119104 7501.7U 48.5 52.1 2,4-Dinitrophenol ug/L R1250451-18190 6825026.0U 112 226 2,4-Dinitrotoluene ug/L 50 103 39-139113 9501.6U 51.6 56.4 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 43 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qual% RecConc. 3808538MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 35753351001 3808539 MSD Result MSD % Rec RPD MSDMS Spike Conc. 2,6-Dinitrotoluene ug/L 50 93 50-158107 14501.7U 46.7 53.5 2-Chloronaphthalene ug/L M1505860-11868 15501.7U 29.2 33.9 2-Chlorophenol ug/L 50 56 23-13462 10501.2U 27.9 30.8 2-Nitrophenol ug/L 50 68 29-18272 6501.4U 33.8 36.0 3,3'-Dichlorobenzidine ug/L 100 94 1-26299 51008.1U 93.5 98.6 4,6-Dinitro-2-methylphenol ug/L R1100721-181106 391007.8U 72.0 106 4-Bromophenylphenyl ether ug/L 50 74 53-12783 11501.8U 37.0 41.5 4-Chloro-3-methylphenol ug/L 100 79 22-14787 101003.3U 78.6 86.5 4-Chlorophenylphenyl ether ug/L 50 76 25-15888 14502.0U 38.1 43.8 4-Nitrophenol ug/L R1250311-13257 602506.6U 77.1 142 Acenaphthene ug/L 50 69 47-14578 12502.0U 34.5 39.1 Acenaphthylene ug/L 50 68 33-14577 12502.0U 34.2 38.4 Anthracene ug/L 50 71 1-16680 11502.3U 35.7 39.9 Benzo(a)anthracene ug/L 50 84 33-14391 7502.7U 42.1 45.3 Benzo(a)pyrene ug/L 50 83 17-16387 4502.8U 41.7 43.4 Benzo(b)fluoranthene ug/L 50 83 24-15988 6502.6U 41.5 43.9 Benzo(g,h,i)perylene ug/L 50 90 1-21992 3502.8U 44.8 46.1 Benzo(k)fluoranthene ug/L 50 83 11-16285 2502.7U 41.7 42.7 bis(2-Chloroethoxy)methane ug/L 50 63 33-18468 7501.8U 31.7 34.1 bis(2-Chloroethyl) ether ug/L 50 59 12-15863 7501.9U 29.4 31.5 bis(2-Ethylhexyl)phthalate ug/L 50 102 8-158109 7503.7U 50.8 54.7 Butylbenzylphthalate ug/L 50 99 1-152113 13503.1U 49.6 56.3 Chrysene ug/L 50 83 17-16891 9502.8U 41.6 45.6 Di-n-butylphthalate ug/L 50 98 1-118108 9502.2U 49.2 53.8 Di-n-octylphthalate ug/L 50 114 4-146124 9503.9U 56.8 62.2 Dibenz(a,h)anthracene ug/L 50 86 1-22791 5503.0U 43.1 45.3 Diethylphthalate ug/L 50 92 1-114100 9502.0U 46.0 50.2 Dimethylphthalate ug/L 50 86 1-11297 12502.1U 43.0 48.4 Fluoranthene ug/L 50 92 26-137100 9502.2U 45.9 50.2 Fluorene ug/L 50 78 59-12189 14502.1U 38.9 44.7 Hexachloro-1,3-butadiene ug/L M150624-1168501.8U 3J 4J Hexachlorobenzene ug/L 50 82 1-15289 9502.2U 40.8 44.5 Hexachlorocyclopentadiene ug/L M1502325-15030 28501.6U 11.4 15.0 Hexachloroethane ug/L M150640-1136501.4U 2.8J 2.8J Indeno(1,2,3-cd)pyrene ug/L 50 93 1-17195 3502.9U 46.3 47.6 Isophorone ug/L 50 72 21-19679 9501.7U 35.8 39.3 N-Nitroso-di-n-propylamine ug/L 50 69 1-23079 13501.3U 34.3 39.3 N-Nitrosodimethylamine ug/L 50 55 25-15066 18501.9U 27.5 32.9 N-Nitrosodiphenylamine ug/L 50 79 25-15087 10503.0U 39.7 43.7 Naphthalene ug/L 50 28 21-13330 7502.1U 13.9 15.0 Nitrobenzene ug/L 50 62 35-18064 3501.9U 31.0 32.0 Pentachlorophenol ug/L R11006314-17688 321003.8U 63.2 87.6 Phenanthrene ug/L 50 83 54-12089 6502.0U 41.7 44.3 Phenol ug/L 50 41 5-11252 24501.4U 20.5 26.0 Pyrene ug/L 50 74 52-11583 11502.2U 37.2 41.5 2,4,6-Tribromophenol (S)%84 10-13797 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 44 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qual% RecConc. 3808538MATRIX SPIKE & MATRIX SPIKE DUPLICATE: MSSpike Result 35753351001 3808539 MSD Result MSD % Rec RPD MSDMS Spike Conc. 2-Fluorobiphenyl (S)%50 15-12047 2-Fluorophenol (S)%42 10-12050 Nitrobenzene-d5 (S)%65 10-12063 Phenol-d6 (S)%38 10-12048 Terphenyl-d14 (S)%83 11-13191 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 45 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 730982 EPA 3546 EPA 8270E 8270E Solid MSSV Microwave Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3805733 Associated Lab Samples:92631278003 Matrix: Solid Analyzed 1,2,4-Trichlorobenzene ug/kg ND 333 v110/19/22 09:05 1,2-Dichlorobenzene ug/kg ND 333 10/19/22 09:05 1,3-Dichlorobenzene ug/kg ND 333 10/19/22 09:05 1,4-Dichlorobenzene ug/kg ND 333 10/19/22 09:05 1-Methylnaphthalene ug/kg ND 333 10/19/22 09:05 2,2'-Oxybis(1-chloropropane)ug/kg ND 333 v210/19/22 09:05 2,4,5-Trichlorophenol ug/kg ND 333 10/19/22 09:05 2,4,6-Trichlorophenol ug/kg ND 333 10/19/22 09:05 2,4-Dichlorophenol ug/kg ND 333 10/19/22 09:05 2,4-Dimethylphenol ug/kg ND 333 10/19/22 09:05 2,4-Dinitrophenol ug/kg ND 1670 10/19/22 09:05 2,4-Dinitrotoluene ug/kg ND 333 10/19/22 09:05 2,6-Dinitrotoluene ug/kg ND 333 10/19/22 09:05 2-Chloronaphthalene ug/kg ND 333 10/19/22 09:05 2-Chlorophenol ug/kg ND 333 10/19/22 09:05 2-Methylnaphthalene ug/kg ND 333 10/19/22 09:05 2-Methylphenol(o-Cresol)ug/kg ND 333 10/19/22 09:05 2-Nitroaniline ug/kg ND 1670 10/19/22 09:05 2-Nitrophenol ug/kg ND 333 10/19/22 09:05 3&4-Methylphenol(m&p Cresol)ug/kg ND 333 10/19/22 09:05 3,3'-Dichlorobenzidine ug/kg ND 667 10/19/22 09:05 3-Nitroaniline ug/kg ND 1670 10/19/22 09:05 4,6-Dinitro-2-methylphenol ug/kg ND 667 10/19/22 09:05 4-Bromophenylphenyl ether ug/kg ND 333 10/19/22 09:05 4-Chloro-3-methylphenol ug/kg ND 667 v110/19/22 09:05 4-Chloroaniline ug/kg ND 667 10/19/22 09:05 4-Chlorophenylphenyl ether ug/kg ND 333 10/19/22 09:05 4-Nitroaniline ug/kg ND 667 10/19/22 09:05 4-Nitrophenol ug/kg ND 1670 v110/19/22 09:05 Acenaphthene ug/kg ND 333 10/19/22 09:05 Acenaphthylene ug/kg ND 333 10/19/22 09:05 Aniline ug/kg ND 333 10/19/22 09:05 Anthracene ug/kg ND 333 10/19/22 09:05 Benzo(a)anthracene ug/kg ND 333 10/19/22 09:05 Benzo(a)pyrene ug/kg ND 333 10/19/22 09:05 Benzo(b)fluoranthene ug/kg ND 333 10/19/22 09:05 Benzo(g,h,i)perylene ug/kg ND 333 10/19/22 09:05 Benzo(k)fluoranthene ug/kg ND 333 10/19/22 09:05 Benzoic Acid ug/kg ND 1670 10/19/22 09:05 Benzyl alcohol ug/kg ND 667 10/19/22 09:05 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 46 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3805733 Associated Lab Samples:92631278003 Matrix: Solid Analyzed bis(2-Chloroethoxy)methane ug/kg ND 333 10/19/22 09:05 bis(2-Chloroethyl) ether ug/kg ND 333 10/19/22 09:05 bis(2-Ethylhexyl)phthalate ug/kg ND 333 10/19/22 09:05 Butylbenzylphthalate ug/kg ND 333 10/19/22 09:05 Chrysene ug/kg ND 333 10/19/22 09:05 Di-n-butylphthalate ug/kg ND 333 10/19/22 09:05 Di-n-octylphthalate ug/kg ND 333 10/19/22 09:05 Dibenz(a,h)anthracene ug/kg ND 333 10/19/22 09:05 Dibenzofuran ug/kg ND 333 10/19/22 09:05 Diethylphthalate ug/kg ND 333 10/19/22 09:05 Dimethylphthalate ug/kg ND 333 10/19/22 09:05 Fluoranthene ug/kg ND 333 10/19/22 09:05 Fluorene ug/kg ND 333 10/19/22 09:05 Hexachloro-1,3-butadiene ug/kg ND 333 v110/19/22 09:05 Hexachlorobenzene ug/kg ND 333 10/19/22 09:05 Hexachlorocyclopentadiene ug/kg ND 333 10/19/22 09:05 Hexachloroethane ug/kg ND 333 10/19/22 09:05 Indeno(1,2,3-cd)pyrene ug/kg ND 333 10/19/22 09:05 Isophorone ug/kg ND 333 10/19/22 09:05 N-Nitroso-di-n-propylamine ug/kg ND 333 10/19/22 09:05 N-Nitrosodimethylamine ug/kg ND 333 10/19/22 09:05 N-Nitrosodiphenylamine ug/kg ND 333 10/19/22 09:05 Naphthalene ug/kg ND 333 10/19/22 09:05 Nitrobenzene ug/kg ND 333 10/19/22 09:05 Pentachlorophenol ug/kg ND 667 10/19/22 09:05 Phenanthrene ug/kg ND 333 10/19/22 09:05 Phenol ug/kg ND 333 10/19/22 09:05 Pyrene ug/kg ND 333 10/19/22 09:05 Pyridine ug/kg ND 333 10/19/22 09:05 2,4,6-Tribromophenol (S)%77 10-131 10/19/22 09:05 2-Fluorobiphenyl (S)%69 10-130 10/19/22 09:05 2-Fluorophenol (S)%67 10-130 10/19/22 09:05 Nitrobenzene-d5 (S)%68 10-130 10/19/22 09:05 Phenol-d6 (S)%64 10-130 10/19/22 09:05 Terphenyl-d14 (S)%75 10-130 10/19/22 09:05 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3805734LABORATORY CONTROL SAMPLE: LCSSpike 1,2,4-Trichlorobenzene ug/kg 1060 v1168063 43-130 1,2-Dichlorobenzene ug/kg 9161680 55 43-130 1,3-Dichlorobenzene ug/kg 8651680 52 43-130 1,4-Dichlorobenzene ug/kg 8421680 50 44-130 1-Methylnaphthalene ug/kg 10501680 62 47-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 47 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3805734LABORATORY CONTROL SAMPLE: LCSSpike 2,2'-Oxybis(1-chloropropane)ug/kg 318J L2,v3168019 29-130 2,4,5-Trichlorophenol ug/kg 11501680 69 47-130 2,4,6-Trichlorophenol ug/kg 11201680 67 47-130 2,4-Dichlorophenol ug/kg 10101680 60 45-130 2,4-Dimethylphenol ug/kg 12601680 75 45-130 2,4-Dinitrophenol ug/kg 55608390 66 27-140 2,4-Dinitrotoluene ug/kg 12101680 72 46-130 2,6-Dinitrotoluene ug/kg 11501680 69 48-130 2-Chloronaphthalene ug/kg 9991680 60 46-130 2-Chlorophenol ug/kg 8651680 52 43-130 2-Methylnaphthalene ug/kg 9901680 59 47-130 2-Methylphenol(o-Cresol)ug/kg 9801680 58 42-130 2-Nitroaniline ug/kg 21703360 65 41-130 2-Nitrophenol ug/kg 9741680 58 48-130 3&4-Methylphenol(m&p Cresol)ug/kg 9921680 59 39-130 3,3'-Dichlorobenzidine ug/kg 21603360 64 41-130 3-Nitroaniline ug/kg 18603360 56 37-130 4,6-Dinitro-2-methylphenol ug/kg 23503360 70 38-141 4-Bromophenylphenyl ether ug/kg 12601680 75 47-130 4-Chloro-3-methylphenol ug/kg 2430 v1336073 44-130 4-Chloroaniline ug/kg 19603360 58 41-130 4-Chlorophenylphenyl ether ug/kg 12801680 76 45-130 4-Nitroaniline ug/kg 20303360 60 42-130 4-Nitrophenol ug/kg 6830 v1839081 39-131 Acenaphthene ug/kg 9971680 59 49-130 Acenaphthylene ug/kg 11001680 65 50-130 Aniline ug/kg 8511680 51 38-130 Anthracene ug/kg 10001680 60 49-130 Benzo(a)anthracene ug/kg 11601680 69 51-130 Benzo(a)pyrene ug/kg 11901680 71 51-130 Benzo(b)fluoranthene ug/kg 10901680 65 49-130 Benzo(g,h,i)perylene ug/kg 11101680 66 48-140 Benzo(k)fluoranthene ug/kg 10301680 61 51-130 Benzoic Acid ug/kg 39908390 48 22-130 Benzyl alcohol ug/kg 20103360 60 43-130 bis(2-Chloroethoxy)methane ug/kg 9141680 54 43-130 bis(2-Chloroethyl) ether ug/kg 8311680 50 42-130 bis(2-Ethylhexyl)phthalate ug/kg 10801680 65 43-130 Butylbenzylphthalate ug/kg 10901680 65 44-131 Chrysene ug/kg 11501680 69 51-130 Di-n-butylphthalate ug/kg 10901680 65 46-130 Di-n-octylphthalate ug/kg 11601680 69 45-130 Dibenz(a,h)anthracene ug/kg 11301680 68 48-130 Dibenzofuran ug/kg 11601680 69 10-130 Diethylphthalate ug/kg 11801680 70 48-130 Dimethylphthalate ug/kg 11801680 70 48-130 Fluoranthene ug/kg 12101680 72 48-130 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 48 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3805734LABORATORY CONTROL SAMPLE: LCSSpike Fluorene ug/kg 11901680 71 48-130 Hexachloro-1,3-butadiene ug/kg 1040 v1168062 39-130 Hexachlorobenzene ug/kg 12401680 74 47-130 Hexachlorocyclopentadiene ug/kg 7681680 46 17-130 Hexachloroethane ug/kg 8981680 54 40-130 Indeno(1,2,3-cd)pyrene ug/kg 11201680 67 50-130 Isophorone ug/kg 9801680 58 41-130 N-Nitroso-di-n-propylamine ug/kg 10501680 63 36-130 N-Nitrosodimethylamine ug/kg 8071680 48 34-130 N-Nitrosodiphenylamine ug/kg 10801680 65 48-130 Naphthalene ug/kg 9101680 54 46-130 Nitrobenzene ug/kg 9801680 58 39-130 Pentachlorophenol ug/kg 21303360 63 42-130 Phenanthrene ug/kg 11001680 66 50-130 Phenol ug/kg 9021680 54 42-130 Pyrene ug/kg 11501680 68 50-130 Pyridine ug/kg 7801680 46 26-130 2,4,6-Tribromophenol (S)%79 10-131 2-Fluorobiphenyl (S)%63 10-130 2-Fluorophenol (S)%56 10-130 Nitrobenzene-d5 (S)%60 10-130 Phenol-d6 (S)%59 10-130 Terphenyl-d14 (S)%70 10-130 Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3805735MATRIX SPIKE SAMPLE: MSSpike Result 92631485002 1,2,4-Trichlorobenzene ug/kg 1590 v1198080 16-130ND 1,2-Dichlorobenzene ug/kg 11801980 59 19-130ND 1,3-Dichlorobenzene ug/kg 11401980 57 19-130ND 1,4-Dichlorobenzene ug/kg 10901980 55 20-130ND 1-Methylnaphthalene ug/kg 24501980 83 19-130798 2,2'-Oxybis(1-chloropropane)ug/kg 413 v3198021 10-130ND 2,4,5-Trichlorophenol ug/kg 14501980 73 19-130ND 2,4,6-Trichlorophenol ug/kg 15201980 76 18-130ND 2,4-Dichlorophenol ug/kg 16201980 81 16-130ND 2,4-Dimethylphenol ug/kg 18801980 95 10-130ND 2,4-Dinitrophenol ug/kg 76009920 77 10-143ND 2,4-Dinitrotoluene ug/kg 16001980 81 19-130ND 2,6-Dinitrotoluene ug/kg 13901980 70 22-130ND 2-Chloronaphthalene ug/kg 12801980 64 18-130ND 2-Chlorophenol ug/kg 12201980 61 20-130ND 2-Methylnaphthalene ug/kg 36701980 95 18-1301790 2-Methylphenol(o-Cresol)ug/kg 13501980 68 13-130ND 2-Nitroaniline ug/kg 27903970 70 18-130ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 49 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3805735MATRIX SPIKE SAMPLE: MSSpike Result 92631485002 2-Nitrophenol ug/kg 14201980 72 19-130ND 3&4-Methylphenol(m&p Cresol)ug/kg 12601980 64 13-130ND 3,3'-Dichlorobenzidine ug/kg 29403970 74 10-130ND 3-Nitroaniline ug/kg 24503970 62 22-130ND 4,6-Dinitro-2-methylphenol ug/kg 29403970 74 10-144ND 4-Bromophenylphenyl ether ug/kg 15301980 77 18-130ND 4-Chloro-3-methylphenol ug/kg 3200 v1397081 16-130ND 4-Chloroaniline ug/kg 26503970 67 17-130ND 4-Chlorophenylphenyl ether ug/kg 16501980 83 17-130ND 4-Nitroaniline ug/kg 23103970 58 21-130ND 4-Nitrophenol ug/kg 9270 v1992094 13-131ND Acenaphthene ug/kg 13201980 67 20-130ND Acenaphthylene ug/kg 14001980 71 21-130ND Aniline ug/kg 10801980 54 10-130ND Anthracene ug/kg 12201980 62 19-130ND Benzo(a)anthracene ug/kg 13801980 69 17-130ND Benzo(a)pyrene ug/kg 14101980 71 14-130ND Benzo(b)fluoranthene ug/kg 12401980 62 11-134ND Benzo(g,h,i)perylene ug/kg 14401980 72 12-130ND Benzo(k)fluoranthene ug/kg 12301980 62 15-130ND Benzoic Acid ug/kg 62709920 63 10-130ND Benzyl alcohol ug/kg 25303970 64 20-130ND bis(2-Chloroethoxy)methane ug/kg 13301980 67 16-130ND bis(2-Chloroethyl) ether ug/kg 11901980 60 18-130ND bis(2-Ethylhexyl)phthalate ug/kg 12801980 64 11-130ND Butylbenzylphthalate ug/kg 13101980 66 10-130ND Chrysene ug/kg 13701980 69 17-130ND Di-n-butylphthalate ug/kg 13201980 66 16-130ND Di-n-octylphthalate ug/kg 13601980 69 16-130ND Dibenz(a,h)anthracene ug/kg 14601980 74 13-130ND Dibenzofuran ug/kg 14901980 75 19-130ND Diethylphthalate ug/kg 15101980 76 22-130ND Dimethylphthalate ug/kg 14401980 73 23-130ND Fluoranthene ug/kg 14801980 75 14-130ND Fluorene ug/kg 14901980 75 19-130ND Hexachloro-1,3-butadiene ug/kg 1480 v1198075 12-130ND Hexachlorobenzene ug/kg 15201980 77 17-130ND Hexachlorocyclopentadiene ug/kg 10901980 55 10-130ND Hexachloroethane ug/kg 13401980 67 14-130ND Indeno(1,2,3-cd)pyrene ug/kg 14001980 71 13-130ND Isophorone ug/kg 13401980 68 17-130ND N-Nitroso-di-n-propylamine ug/kg 14801980 75 10-130ND N-Nitrosodimethylamine ug/kg 11101980 56 16-130ND N-Nitrosodiphenylamine ug/kg 13201980 67 19-130ND Naphthalene ug/kg 20801980 76 18-130576 Nitrobenzene ug/kg 14001980 71 15-130ND Pentachlorophenol ug/kg 26903970 68 10-130ND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 50 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units MS Result % Rec Limits Qualifiers% RecConc. 3805735MATRIX SPIKE SAMPLE: MSSpike Result 92631485002 Phenanthrene ug/kg 13601980 68 17-130ND Phenol ug/kg 10801980 55 15-130ND Pyrene ug/kg 13001980 66 31-130ND Pyridine ug/kg 8991980 45 10-130ND 2,4,6-Tribromophenol (S)%74 10-131 2-Fluorobiphenyl (S)%65 10-130 2-Fluorophenol (S)%63 10-130 Nitrobenzene-d5 (S)%74 10-130 Phenol-d6 (S)%61 10-130 Terphenyl-d14 (S)%66 10-130 Parameter Units Dup Result QualifiersRPDResult 92631485001 3805736SAMPLE DUPLICATE: 1,2,4-Trichlorobenzene ug/kg ND v1ND 1,2-Dichlorobenzene ug/kg NDND 1,3-Dichlorobenzene ug/kg NDND 1,4-Dichlorobenzene ug/kg NDND 1-Methylnaphthalene ug/kg NDND 2,2'-Oxybis(1-chloropropane)ug/kg ND v2ND 2,4,5-Trichlorophenol ug/kg NDND 2,4,6-Trichlorophenol ug/kg NDND 2,4-Dichlorophenol ug/kg NDND 2,4-Dimethylphenol ug/kg NDND 2,4-Dinitrophenol ug/kg NDND 2,4-Dinitrotoluene ug/kg NDND 2,6-Dinitrotoluene ug/kg NDND 2-Chloronaphthalene ug/kg NDND 2-Chlorophenol ug/kg NDND 2-Methylnaphthalene ug/kg NDND 2-Methylphenol(o-Cresol)ug/kg NDND 2-Nitroaniline ug/kg NDND 2-Nitrophenol ug/kg NDND 3&4-Methylphenol(m&p Cresol)ug/kg NDND 3,3'-Dichlorobenzidine ug/kg NDND 3-Nitroaniline ug/kg NDND 4,6-Dinitro-2-methylphenol ug/kg NDND 4-Bromophenylphenyl ether ug/kg NDND 4-Chloro-3-methylphenol ug/kg ND v1ND 4-Chloroaniline ug/kg NDND 4-Chlorophenylphenyl ether ug/kg NDND 4-Nitroaniline ug/kg NDND 4-Nitrophenol ug/kg ND v1ND Acenaphthene ug/kg NDND Acenaphthylene ug/kg NDND REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 51 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. Parameter Units Dup Result QualifiersRPDResult 92631485001 3805736SAMPLE DUPLICATE: Aniline ug/kg NDND Anthracene ug/kg NDND Benzo(a)anthracene ug/kg NDND Benzo(a)pyrene ug/kg NDND Benzo(b)fluoranthene ug/kg NDND Benzo(g,h,i)perylene ug/kg NDND Benzo(k)fluoranthene ug/kg NDND Benzoic Acid ug/kg NDND Benzyl alcohol ug/kg NDND bis(2-Chloroethoxy)methane ug/kg NDND bis(2-Chloroethyl) ether ug/kg NDND bis(2-Ethylhexyl)phthalate ug/kg NDND Butylbenzylphthalate ug/kg NDND Chrysene ug/kg NDND Di-n-butylphthalate ug/kg NDND Di-n-octylphthalate ug/kg NDND Dibenz(a,h)anthracene ug/kg NDND Dibenzofuran ug/kg NDND Diethylphthalate ug/kg NDND Dimethylphthalate ug/kg NDND Fluoranthene ug/kg NDND Fluorene ug/kg NDND Hexachloro-1,3-butadiene ug/kg ND v1ND Hexachlorobenzene ug/kg NDND Hexachlorocyclopentadiene ug/kg NDND Hexachloroethane ug/kg NDND Indeno(1,2,3-cd)pyrene ug/kg NDND Isophorone ug/kg NDND N-Nitroso-di-n-propylamine ug/kg NDND N-Nitrosodimethylamine ug/kg NDND N-Nitrosodiphenylamine ug/kg NDND Naphthalene ug/kg NDND Nitrobenzene ug/kg NDND Pentachlorophenol ug/kg NDND Phenanthrene ug/kg NDND Phenol ug/kg NDND Pyrene ug/kg NDND Pyridine ug/kg NDND 2,4,6-Tribromophenol (S)%6865 2-Fluorobiphenyl (S)%5246 2-Fluorophenol (S)%5541 Nitrobenzene-d5 (S)%5951 Phenol-d6 (S)%5241 Terphenyl-d14 (S)%6066 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 52 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 730694 MADEP EPH MADEP EPH MADEP EPH NC Soil Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278003 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3804517 Associated Lab Samples:92631278003 Matrix: Solid Analyzed Aliphatic (C09-C18)mg/kg ND 10.0 N210/21/22 09:00 Aliphatic (C19-C36)mg/kg ND 10.0 N210/21/22 09:00 Aromatic (C11-C22)mg/kg ND 10.0 N210/21/22 09:00 1-Chlorooctadecane (S)%75 40-140 10/21/22 09:00 2-Bromonaphthalene (S)%122 40-140 10/21/22 09:00 2-Fluorobiphenyl (S)%115 40-140 10/21/22 09:00 o-Terphenyl (S)%74 40-140 10/21/22 09:00 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3804518LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 3804519 Aliphatic (C09-C18)mg/kg ND N210.1 47 40-14048ND 50 Aliphatic (C19-C36)mg/kg ND N213.5 70 40-14073ND 50 Aromatic (C11-C22)mg/kg 21.7 N228.6 76 40-1406919.3 12 50 1-Chlorooctadecane (S)%73 40-14070 2-Bromonaphthalene (S)%127 40-140114 2-Fluorobiphenyl (S)%122 40-140110 o-Terphenyl (S)%78 40-14066 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 53 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 732295 MADEP EPH MADEP EPH MADEP EPH NC Water Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278006 Parameter Units Blank Result Reporting Limit Qualifiers METHOD BLANK: 3811677 Associated Lab Samples:92631278006 Matrix: Water Analyzed Aliphatic (C09-C18)ug/L ND 100 N210/25/22 14:51 Aliphatic (C19-C36)ug/L ND 100 N210/25/22 14:51 Aromatic (C11-C22)ug/L ND 100 N210/25/22 14:51 1-Chlorooctadecane (S)%57 40-140 10/25/22 14:51 2-Bromonaphthalene (S)%110 40-140 10/25/22 14:51 2-Fluorobiphenyl (S)%107 40-140 10/25/22 14:51 o-Terphenyl (S)%76 40-140 10/25/22 14:51 Parameter Units LCS Result % Rec Limits Qualifiers% RecConc. 3811678LABORATORY CONTROL SAMPLE & LCSD: LCSSpike LCSD % Rec RPD Max RPD LCSD Result 3811679 Aliphatic (C09-C18)ug/L 141 N23004740-14057170 18 50 Aliphatic (C19-C36)ug/L 364 N24009140-14091365 0 50 Aromatic (C11-C22)ug/L 675 N28507940-14078662 2 50 1-Chlorooctadecane (S)%60 40-14062 2-Bromonaphthalene (S)%100 40-14073 2-Fluorobiphenyl (S)%102 40-14075 o-Terphenyl (S)%80 40-14081 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 54 of 75 #=QC# QUALITY CONTROL DATA Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. QC Batch: QC Batch Method: Analysis Method: Analysis Description: 731027 SW-846 SW-846 Dry Weight/Percent Moisture Laboratory:Pace Analytical Services - Charlotte Associated Lab Samples: 92631278001, 92631278002, 92631278003 Parameter Units Dup Result QualifiersRPDResult 92631249001 3805907SAMPLE DUPLICATE: Percent Moisture %23.3 N2721.8 Parameter Units Dup Result QualifiersRPDResult 92631455005 3805908SAMPLE DUPLICATE: Percent Moisture %22.0 N2221.5 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 55 of 75 #=QL# QUALIFIERS Pace Project No.: Project: 92631278 C&H SHELL 2021-080 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL - Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean-Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPAMethod 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Reported results are not rounded until the final step prior to reporting. Therefore, calculated parameters that are typically reported as "Total" may vary slightly from the sum of the reported component parameters. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS Result may be biased high due to carryover from previously analyzed sample.C8 Analyte concentration exceeded the calibration range. The reported result is estimated.E Analyte recovery in the laboratory control sample (LCS) was above QC limits. Results for this analyte in associatedsamples may be biased high.L1 Analyte recovery in the laboratory control sample (LCS) was below QC limits. Results for this analyte in associated samples may be biased low.L2 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.M1 The reported TIC has an 85% or higher match on a mass spectral library search.N The lab does not hold NELAC/TNI accreditation for this parameter but other accreditations/certifications may apply. A complete list of accreditations/certifications is available upon request.N2 RPD value was outside control limits.R1 Surrogate recovery outside laboratory control limits due to matrix interferences (confirmed by similar results from sample re-analysis).S2 The continuing calibration verification was above the method acceptance limit. Any detection for the analyte in the associated samples may have a high bias.v1 The continuing calibration verification was below the method acceptance limit. The analyte was not detected in the associated samples and the sensitivity of the instrument was verified with a reporting limit check standard.v2 The continuing calibration verification was below the method acceptance limit. Any detection for the analyte in the associated samples may have low bias.v3 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 56 of 75 #=CR# QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Project No.: Project: 92631278 C&H SHELL 2021-080 Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92631278004 732287 732386MW-1 EPA 504.1 EPA 504.1 92631278005 732287 732386MW-2 EPA 504.1 EPA 504.1 92631278006 732287 732386MW-3 EPA 504.1 EPA 504.1 92631278003 730694 731888MW-3 (5-6)MADEP EPH MADEP EPH 92631278006 732295 732806MW-3 MADEP EPH MADEP EPH 92631278001 733579 733582MW-1 (5-6)MADEP VPH MADEP VPH 92631278002 733579 733582MW-2 (5-6)MADEP VPH MADEP VPH 92631278003 731297 731415MW-3 (5-6)MADEP VPH MADEP VPH 92631278004 732879 732910MW-1 EPA 3010A EPA 6010D 92631278005 732879 732910MW-2 EPA 3010A EPA 6010D 92631278006 732879 732910MW-3 EPA 3010A EPA 6010D 92631278006 731589 731774MW-3 EPA 625.1 EPA 625.1 92631278003 730982 731233MW-3 (5-6)EPA 3546 EPA 8270E 92631278004 732223MW-1 SM 6200B 92631278005 732655MW-2 SM 6200B 92631278006 732223MW-3 SM 6200B 92631278001 731067 731108MW-1 (5-6)EPA 5035A/5030B EPA 8260D 92631278002 731067 731108MW-2 (5-6)EPA 5035A/5030B EPA 8260D 92631278003 731067 731108MW-3 (5-6)EPA 5035A/5030B EPA 8260D 92631278001 731027MW-1 (5-6)SW-846 92631278002 731027MW-2 (5-6)SW-846 92631278003 731027MW-3 (5-6)SW-846 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC.Date: 11/01/2022 03:05 PM Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Page 57 of 75 Page 58 of 75 Page 59 of 75 Page 60 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 October 28, 2022 Angela Baioni Pace Analytical Services - NC 9800 Kincey Avenue, Suite 100 Huntersville, NC 28078 Project Location: C&H Shell 2021-080 Client Job Number: Project Number: 92631278 Laboratory Work Order Number: 22J3711 Enclosed are results of analyses for samples as received by the laboratory on October 26, 2022. If you have any questions concerning this report, please feel free to contact me. Sincerely, Kerry K. McGee Project Manager Page 61 of 75 Table of Contents Sample Summary 3 Case Narrative 4 Sample Results 5 22J3711-01 5 22J3711-02 6 22J3711-03 7 Sample Preparation Information 8 QC Data 9 Petroleum Hydrocarbons Analyses - VPH 9 B321198 9 Flag/Qualifier Summary 11 Certifications 12 Chain of Custody/Sample Receipt 13 Page 62 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 ANALYTICAL SUMMARY 10/28/2022 Pace Analytical Services - NC 9800 Kincey Avenue, Suite 100 Huntersville, NC 28078 ATTN: Angela Baioni 92631278 22J3711 The results of analyses performed on the following samples submitted to CON-TEST, a Pace Analytical Laboratory, are found in this report. PROJECT LOCATION: PURCHASE ORDER NUMBER: PROJECT NUMBER: REPORT DATE: WORK ORDER NUMBER: FIELD SAMPLE #LAB ID:MATRIX TESTSAMPLE DESCRIPTION SUB LAB C&H Shell 2021-080 MW-1 22J3711-01 Water MADEP-VPH-Feb 2018 Rev 2.1 MW-2 22J3711-02 Water MADEP-VPH-Feb 2018 Rev 2.1 MW-3 22J3711-03 Water MADEP-VPH-Feb 2018 Rev 2.1 [TOC_1]Sample Summary[TOC] Page 63 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 CASE NARRATIVE SUMMARY All reported results are within defined laboratory quality control objectives unless listed below or otherwise qualified in this report. For method MA VPH only hydrocarbon ranges were requested and reported. [TOC_1]Case Narrative[TOC] MADEP-VPH-Feb 2018 Rev 2.1 No significant modifications were made to the method. All VPH samples were received preserved properly at pH <2 in the proper containers as specified on the chain-of-custody form unless specified in this narrative. Analytical column used for VPH analysis is Restek, Rtx-502.2, 105meter, 0.53mmID, 3um df. Trap used for VPH analysis is Carbopack B/CarboSieveS-III. The results of analyses reported only relate to samples submitted to Con-Test, a Pace Analytical Laboratory, for testing. I certify that the analyses listed above, unless specifically listed as subcontracted, if any, were performed under my direction according to the approved methodologies listed in this document, and that based upon my inquiry of those individuals immediately responsible for obtaining the information, the material contained in this report is, to the best of my knowledge and belief, accurate and complete. Tod E. Kopyscinski Laboratory Director Page 64 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 Date Received: 10/26/2022 Work Order: 22J3711Sample Description:Project Location: C&H Shell 2021-080 Sample ID: 22J3711-01 Field Sample #: MW-1 Sample Matrix: Water Sampled: 10/13/2022 00:00 [TOC_2]22J3711-01[TOC] AnalystAnalyzedDilutionFlag/QualRLResultsAnalyte Date/Time Units Date PreparedMethod Petroleum Hydrocarbons Analyses - VPH 2400 500 10/27/22 6:05 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 5Unadjusted C5-C8 Aliphatics 2400 500 10/27/22 6:05 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 5C5-C8 Aliphatics 1700 500 10/27/22 6:05 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 5Unadjusted C9-C12 Aliphatics ND 500 10/27/22 6:05 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 5C9-C12 Aliphatics 1300 500 10/27/22 6:05 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 5C9-C10 Aromatics Surrogates % Recovery Recovery Limits Flag/Qual 2,5-Dibromotoluene (FID)104 10/27/22 6:0570-130 2,5-Dibromotoluene (PID)96.6 10/27/22 6:0570-130 [TOC_1]Sample Results[TOC] Page 65 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 Date Received: 10/26/2022 Work Order: 22J3711Sample Description:Project Location: C&H Shell 2021-080 Sample ID: 22J3711-02 Field Sample #: MW-2 Sample Matrix: Water Sampled: 10/13/2022 00:00 [TOC_2]22J3711-02[TOC] AnalystAnalyzedDilutionFlag/QualRLResultsAnalyte Date/Time Units Date PreparedMethod Petroleum Hydrocarbons Analyses - VPH ND 100 10/27/22 4:36 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1Unadjusted C5-C8 Aliphatics ND 100 10/27/22 4:36 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1C5-C8 Aliphatics ND 100 10/27/22 4:36 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1Unadjusted C9-C12 Aliphatics ND 100 10/27/22 4:36 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1C9-C12 Aliphatics ND 100 10/27/22 4:36 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1C9-C10 Aromatics Surrogates % Recovery Recovery Limits Flag/Qual 2,5-Dibromotoluene (FID)79.8 10/27/22 4:3670-130 2,5-Dibromotoluene (PID)74.9 10/27/22 4:3670-130 Page 66 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 Date Received: 10/26/2022 Work Order: 22J3711Sample Description:Project Location: C&H Shell 2021-080 Sample ID: 22J3711-03 Field Sample #: MW-3 Sample Matrix: Water Sampled: 10/13/2022 00:00 [TOC_2]22J3711-03[TOC] AnalystAnalyzedDilutionFlag/QualRLResultsAnalyte Date/Time Units Date PreparedMethod Petroleum Hydrocarbons Analyses - VPH ND 100 10/27/22 5:06 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1Unadjusted C5-C8 Aliphatics ND 100 10/27/22 5:06 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1C5-C8 Aliphatics ND 100 10/27/22 5:06 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1Unadjusted C9-C12 Aliphatics ND 100 10/27/22 5:06 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1C9-C12 Aliphatics ND 100 10/27/22 5:06 EEHg/L 10/26/22MADEP-VPH-Feb 2018 Rev 2.1 1C9-C10 Aromatics Surrogates % Recovery Recovery Limits Flag/Qual 2,5-Dibromotoluene (FID)79.1 10/27/22 5:0670-130 2,5-Dibromotoluene (PID)76.6 10/27/22 5:0670-130 Page 67 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 Sample Extraction Data Prep Method: MA VPH Analytical Method: MADEP-VPH-Feb 2018 Rev 2.1 Lab Number [Field ID]Batch DateInitial [mL]Final [mL] B321198 10/26/2215.0022J3711-01 [MW-1] B321198 10/26/2255.0022J3711-02 [MW-2] B321198 10/26/2255.0022J3711-03 [MW-3] [TOC_1]Sample Preparation Information[TOC] Page 68 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 Result Limit Reporting Units Level Spike Result Source %REC %REC Limits RPD RPD Limit Notes Analyte Petroleum Hydrocarbons Analyses - VPH - Quality Control QUALITY CONTROL [TOC_2]Petroleum Hydrocarbons Analyses - VPH[TOC] Batch B321198 - MA VPH [TOC_3]B321198[TOC] Blank (B321198-BLK1) Prepared & Analyzed: 10/26/22 Unadjusted C5-C8 Aliphatics g/L100ND C5-C8 Aliphatics g/L100ND Unadjusted C9-C12 Aliphatics g/L100ND C9-C12 Aliphatics g/L100ND C9-C10 Aromatics g/L100ND Benzene g/L1.0ND Butylcyclohexane g/L1.0ND Decane g/L1.0ND Ethylbenzene g/L1.0ND Methyl tert-Butyl Ether (MTBE)g/L1.0ND 2-Methylpentane g/L1.0ND Naphthalene g/L5.0ND Nonane g/L1.0ND Pentane g/L1.0ND Toluene g/L1.0ND 1,2,4-Trimethylbenzene g/L1.0ND 2,2,4-Trimethylpentane g/L1.0ND m+p Xylene g/L2.0ND o-Xylene g/L1.0ND g/L 40.0 70-130Surrogate: 2,5-Dibromotoluene (FID)81.732.7 g/L 40.0 70-130Surrogate: 2,5-Dibromotoluene (PID)72.729.1 LCS (B321198-BS1) Prepared & Analyzed: 10/26/22 Unadjusted C5-C8 Aliphatics g/L100 150 70-13093.8141 Unadjusted C9-C12 Aliphatics g/L100 150 70-130103154 C9-C10 Aromatics g/L100 50.0 70-13010150.3 Benzene g/L1.0 50.0 70-13010150.7 Butylcyclohexane g/L1.0 50.0 70-13011457.0 Decane g/L1.0 50.0 70-13082.141.0 Ethylbenzene g/L1.0 50.0 70-13088.644.3 Methyl tert-Butyl Ether (MTBE)g/L1.0 50.0 70-13010451.9 2-Methylpentane g/L1.0 50.0 70-13092.646.3 Naphthalene g/L5.0 50.0 70-13088.244.1 Nonane g/L1.0 50.0 70-13011356.4 Pentane g/L1.0 50.0 70-13097.448.7 Toluene g/L1.0 50.0 70-13095.147.6 1,2,4-Trimethylbenzene g/L1.0 50.0 70-13010150.3 2,2,4-Trimethylpentane g/L1.0 50.0 70-13091.345.7 m+p Xylene g/L2.0 100 70-13096.396.3 o-Xylene g/L1.0 50.0 70-13010351.7 g/L 40.0 70-130Surrogate: 2,5-Dibromotoluene (FID)11044.0 g/L 40.0 70-130Surrogate: 2,5-Dibromotoluene (PID)97.639.0 [TOC_1]QC Data[TOC] Page 69 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 Result Limit Reporting Units Level Spike Result Source %REC %REC Limits RPD RPD Limit Notes Analyte Petroleum Hydrocarbons Analyses - VPH - Quality Control QUALITY CONTROL Batch B321198 - MA VPH LCS Dup (B321198-BSD1) Prepared & Analyzed: 10/26/22 Unadjusted C5-C8 Aliphatics g/L100 150 2570-13090.3 3.79135 Unadjusted C9-C12 Aliphatics g/L100 150 2570-130100 2.65150 C9-C10 Aromatics g/L100 50.0 2570-13093.2 7.6246.6 Benzene g/L1.0 50.0 2570-13097.9 3.6048.9 Butylcyclohexane g/L1.0 50.0 2570-130111 2.5255.6 Decane g/L1.0 50.0 2570-13079.0 3.7939.5 Ethylbenzene g/L1.0 50.0 2570-13083.3 6.2641.6 Methyl tert-Butyl Ether (MTBE)g/L1.0 50.0 2570-13099.0 4.7049.5 2-Methylpentane g/L1.0 50.0 2570-13092.8 0.23746.4 Naphthalene g/L5.0 50.0 2570-13083.8 5.0341.9 Nonane g/L1.0 50.0 2570-130111 1.9555.3 Pentane g/L1.0 50.0 2570-13093.8 3.7246.9 Toluene g/L1.0 50.0 2570-13094.2 0.99147.1 1,2,4-Trimethylbenzene g/L1.0 50.0 2570-13093.2 7.6246.6 2,2,4-Trimethylpentane g/L1.0 50.0 2570-13084.2 8.1342.1 m+p Xylene g/L2.0 100 2570-13090.5 6.1790.5 o-Xylene g/L1.0 50.0 2570-13096.3 7.0548.2 g/L 40.0 70-130Surrogate: 2,5-Dibromotoluene (FID)92.737.1 g/L 40.0 70-130Surrogate: 2,5-Dibromotoluene (PID)85.134.1 Page 70 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 FLAG/QUALIFIER SUMMARY *QC result is outside of established limits. Wide recovery limits established for difficult compound. Wide RPD limits established for difficult compound. #Data exceeded client recommended or regulatory level Percent recoveries and relative percent differences (RPDs) are determined by the software using values in the calculation which have not been rounded. No results have been blank subtracted unless specified in the case narrative section. RL Reporting Limit is at the level of quantitation (LOQ) DL Detection Limit is the lower limit of detection determined by the MDL study MCL Maximum Contaminant Level ND Not Detected [TOC_1]Flag/Qualifier Summary[TOC] Page 71 of 75 39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332 CertificationsAnalyte CERTIFICATIONS Certified Analyses included in this Report MADEP-VPH-Feb 2018 Rev 2.1 in Water CT,NC,ME,NH-PUnadjusted C5-C8 Aliphatics CT,NC,ME,NH-PC5-C8 Aliphatics CT,NC,ME,NH-PUnadjusted C9-C12 Aliphatics CT,NC,ME,NH-PC9-C12 Aliphatics CT,NC,ME,NH-PC9-C10 Aromatics [TOC_1]Certifications[TOC] Con-Test, a Pace Environmental Laboratory, operates under the following certifications and accreditations: Code Description Number Expires PH-0165Connecticut Department of Public HealthCT 12/31/2022 652North Carolina Div. of Water QualityNC 12/31/2022 MA00100State of MaineME 06/9/2023 2557 NELAPNew Hampshire Environmental LabNH-P 09/6/2023 Page 72 of 75 Page 73 of 75 Page 74 of 75 Page 75 of 75