Loading...
HomeMy WebLinkAbout15032_800 Chatham_SIR_20221108 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 11/09/2022 4:22 PM I. Inspection Information Date & Time: 11/08/2022 9:55 AM Inspection Type: Drive-By Brownfields Staff: Kevin Slaughter, Seth Titley, Tyler Pearson Other Personnel: Maintenance Superintendent Location: Lat: 36.10481671, Long: -80.25470287 Brownfields Inspection Report: 800 Chatham Road, 15032-11-034 11/08/2022 9:55 AM Page 2 of 7 II. Project Information Number: 15032-11-034 Name: 800 Chatham Road Address: 800 Chatham Road City: Winston-Salem County: Forsyth III. Environmental Current Use of Property: Residential Structures on Property: Existing Structures Violation: Unknown Vapor Mitigation Systems: Observed Vapor Mitigation Violation: Unknown Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: Unknown Summary: Two sub-slab vacuum readings were taken from wall mounted access panels within building 12-15 on each end of the atrium. No vacuum was observed at panel P-14- 1 (Photo 6). None of the VIMS testing apparatus (tubing, vapor barrier wrapped masonry walls and bottoms of wood columns in atrium, PVC piping, etc.) has been touched since DEQ’s previous Site Inspection. DEQ personnel inspected active blowers on the roof of building 12-15 that were accessible, and determined that one of the blowers, extracting from the vicinity of sub-slab monitoring point P-14-1 was not operating. DEQ personnel turned the GFI outlet on and off but were unable to restart it. Summary: N/A Summary: Two occupied buildings on the southern half of the property have been renovated for multi-residential apartments. Based on conversation with construction worker encountered wile inspecting the vacant building on the northern portion of the property (resulting from roof work being performed), it is currently in the process of being converted into residential units of some type (Photos 1-3). Summary: Soil along both sides of a sidewalk and concrete stairs located on northern side of building 12-15 has been washed out since prior Site Inspection and mostly covered portions of sidewalk at lower elevation (Photos 4 & 5). Yellow caution tape has been installed across the sidewalk to prevent its use, and pieces of coal and other debris are exposed in both the washed-out soil and in the sidewalls of the intact soil remaining. Brownfields Inspection Report: 800 Chatham Road, 15032-11-034 11/08/2022 9:55 AM Page 3 of 7 Use of Basements: Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: There are maintenance areas, common hallways, residential units, and an atrium that are at least partially below the surrounding grade in building 12-15 (Photos 6 & 7). There are soil contact walls around walk-out type basement in vacant building currently being renovated on northern portion of property (Photos 1-3). Summary: N/A Condition: Summary: N/A Although the area had caution tape installed to prevent pedestrian traffic, there is a washed-out soil area north of building 12-15 as mentioned previously (Photos 4 & 5). This is the general location of the sub-slab/crawl space blower fans that discharge within the breathing zone which has been noted in prior Site Inspection Reports. There is a roof mounted fan building 12-15 that has shut down since DEQ’s April/2022 site inspection (Photos 6 & 7), and the risk is unknown for construction workers currently in the process of remodeling currently vacant building on the northern half of the property (Photos 1-3). Brownfields Inspection Report: 800 Chatham Road, 15032-11-034 11/08/2022 9:55 AM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: View of vacant building being renovated. Photo taken from existing apartment building 12-15 roof. New roof installation can be seen in the photo. The Site Inspection was performed at the request of the DEQ project manager to determine the current condition of the property, and if any additional testing work or test equipment dismantling has occurred in and adjacent to the atrium portion of building 12- 15 (it has not). As mentioned previously, at least one blower on building 12-15 was non-operational at the time of the Site Inspection (there are others on a higher elevation that could not be checked), there is a washed out area along a concrete sidewalk and stairwell that needs to be addressed, and there is work beginning on a large masonry vacant building located on northern portion of property (new roof installed, and contractor meeting scheduled for later that day). Brownfields Inspection Report: 800 Chatham Road, 15032-11-034 11/08/2022 9:55 AM Page 5 of 7 Photo 2: Interior - First floor of vacant building. Photo 3: Interior – Basement level of vacant building. Brownfields Inspection Report: 800 Chatham Road, 15032-11-034 11/08/2022 9:55 AM Page 6 of 7 Photo 4: Both sides of sidewalk and concrete stairs have been washed out, and over lower leave sidewalk. Caution tape has been put up to prevent use. Coal and other debris visible. Photo 5: Additional photo on other side of sidewalk of washed-out area and caution tape. Brownfields Inspection Report: 800 Chatham Road, 15032-11-034 11/08/2022 9:55 AM Page 7 of 7 Photo 6: No vacuum influence measured at P-14-1. A roof blower check was performed as a result. Photo 7: Non-operational blower that extracts from near sub-slab monitoring point in Photo 6. DEQ personnel attempted to restart fan by resetting GFI outlet but were unsuccessful.