HomeMy WebLinkAbout24043_Gas Fired Products_SIR_20220714 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 07/20/2022 10:59 AM I. Inspection Information Date & Time: 07/14/2022 10:27 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter, Tyler Pearson Other Personnel: Shannon Switch – Hart & Hickman (H&H) Location: Lat: 35.21025565, Long: -80.86773396 Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 07/14/2022 10:27 AM Page 2 of 6 II. Project Information Number: 24043-20-060 Name: Gas Fired Products (RN) Address: 421 W. Tremont Avenue City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Residential Structures on Property: New Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Observed Exposed Soils Violation: No Summary: Observed sub-slab piping and gravel inspection on the southeast corner of the property (Photos 1 – 4). On arrival, VIMS piping, and gravel were exposed for the inspection. Following the sub-slab piping/ gravel inspection, contractors began to cover the PVC piping with washed gravel (Photo 4). Summary: N/A Summary: New High Density residential and parking garage. Summary: Exposed soil consistant with construction activities and EMP. Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 07/14/2022 10:27 AM Page 3 of 6 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A No risk to the public observed at the time of the Site Inspection. Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 07/14/2022 10:27 AM Page 4 of 6 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Exposed sub-slab gravel, suction lines, and orange riser stub-up visible in photo. Black foam material was installed over solid VIMS piping where it crossed future footers. Site Inspection scheduled to observe sub-slab piping / gravel inspection being performed by H&H prior to exposed piping being covered with washed stone. VIMS piping layout, and washed stone thickness were acceptable, and contactors began covering piping with washed stone following the inspection. Solid PVC piping had been wrapped in a black foam sheath where it crossing thickened slabs to prevent potential damage (Photos 1-4). Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 07/14/2022 10:27 AM Page 5 of 6 Photo 2: View of VIMS components facing north. Photo 3: Exposed slotted PVC line prior to being covered with gravel (Photo 4) Brownfields Inspection Report: Gas Fired Products (RN), 24043-20-060 07/14/2022 10:27 AM Page 6 of 6 Photo 4: Following the inspection, the suction line shown in Photo 3 was covered with gravel prior to VIMS barrier being installed and tied into edges visible in photo. Photo 5: View of previously inspected lower-level floor slab to the west.