HomeMy WebLinkAbout16041_Fleming Labs_SIR_20220922 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 09/23/2022 6:28 AM I. Inspection Information Date & Time: 09/22/2022 11:22 AM Inspection Type: Drive-By Brownfields Staff: Kevin Slaughter, Seth Titley, Tyler Pearson Other Personnel: Louis Giacomini - Brewerey owner Location: Lat: 35.23395908, Long: -80.873908 Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 09/22/2022 11:22 AM Page 2 of 6 II. Project Information Number: 16041-12-060 Name: Fleming Laboratories-RFRU Address: 2205 - 2215 Thrift Road City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Recreation/Festival Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: Active VIMS, checked vacuums on several riser pipes within southern portion of building, including one several risers, and one vapor pin (photos 1-3). Attempted to open monitoring point, however, unable to remove cap as concrete sealer had worked its way into threaded cap. Although the four roof-top blowers were inspected (Photos 4 & 5), DEQ personnel were unable to enter Summit Seltzery during Site Inspection to check alarm system as business was closed at the time of the inspection. Summary: NA Summary: Single story masonry construction former Fleming Laboratories building has been retrofitted into two brewery type facilities. Summit Seltzery (currently operating) is located within the northern portion of the building, and Midnight Mulligan Brewing, a brewery/restaurant is in the southern portion of the building. Summary: NA Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 09/22/2022 11:22 AM Page 3 of 6 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: NA Summary: NA Condition: Summary: NA No risk to the public observed at the time of the Site Inspection. Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 09/22/2022 11:22 AM Page 4 of 6 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Measuring riser vacuum in “WC within Midnight Mulligan Brewing. All four of the rooftop blowers were operating at the time of the Site Inspection, although the southern blower had more bearing noise than the other three (Photos 4 & 5). As stated previously, unable to check alarm system, and blower vacuums as seltzer business was closed at the time of the Site Inspection. Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 09/22/2022 11:22 AM Page 5 of 6 Photo 2: Close-up of steel riser piping, sample/vacuum port, and labeling behind panel door. Photo 3: Vacuum measurement within Midnight Mulligan Brewing. DEQ personnel attempted to open a second sub-slab vapor pin but were unable due to concrete sealer in the threads. Brownfields Inspection Report: Fleming Laboratories-RFRU, 16041-12-060 09/22/2022 11:22 AM Page 6 of 6 Photo 4: Southern roof-top fan facing east. These fans bearings appeared to be making more noise than a similar blower located on eastern portion of the roof. Photo 5: Dual fans located closer to middle of building roof.