HomeMy WebLinkAbout25032_Domestic Laundry_SIR_20220818 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 08/19/2022 8:32 AM I. Inspection Information Date & Time: 08/18/2022 10:46 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter Other Personnel: Nick Gaston - Whiting-Turner Superintendent, and Jon Joseph - RJ Leeper Location: Lat: 35.21414399, Long: -80.84134548 Brownfields Inspection Report: Domestic Lanudry (RN), 25032-21-060 08/18/2022 10:46 AM Page 2 of 7 II. Project Information Number: 25032-21-060 Name: Domestic Lanudry (RN) Address: 801 S. McDowell St; 900, 928, 943 Baxter St.; 1001, 1017, 1043, 1051 E. Morehead St. City: Charlotte County: Mecklenburg III. Environmental Current Use of Property: Industrial Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Not Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: N/A Summary: N/A Summary: Buildings have not been demolished at the time of the Site Inspection, and no pavement has been removed, although some pavement removal is scheduled for next week. Summary: N/A Brownfields Inspection Report: Domestic Lanudry (RN), 25032-21-060 08/18/2022 10:46 AM Page 3 of 7 Use of Basements: Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: A basement is present within eastern structure, although it is no longer in use (Photo 4). Summary: N/A, however, there were two areas where drums of soil from soil borings were staged. There was almost no information on drum placards regarding contents, contact information, dates collected, etc. (Photo 7). Condition: Summary: N/A The perimeter of the property is surrounded with temporary construction fencing (Photos 1 & 6). No risk to the public was observed at the time of the Site Inspection. Brownfields Inspection Report: Domestic Lanudry (RN), 25032-21-060 08/18/2022 10:46 AM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: View of eastern building from across the intersection of Baxter St. and S. McDowell St. I met with two superintendents at their construction trailer, and the soil disturbance which was supposed to start the previous day had been pushed back to next week. There was no hard copy of EMP onsite which was a result of just getting power to the construction trailer although they did have a copy on their laptop. I requested they print and keep a hard copy onsite, prior to the start of the soil disturbance. A soft kick-off meeting was scheduled the following Monday. I indicated I might attend if notified, however, I was not notified and did not attend. Brownfields Inspection Report: Domestic Lanudry (RN), 25032-21-060 08/18/2022 10:46 AM Page 5 of 7 Photo 2: Eastern side of same building facing west. Photo 3: Southeastern side of eastern building. Initial soil disturbance to take place in this general area, and salvage company vehicles and trailer visible in photo. Brownfields Inspection Report: Domestic Lanudry (RN), 25032-21-060 08/18/2022 10:46 AM Page 6 of 7 Photo 4: Stairwell down to unused basement. Not in use, and inspector did not enter the basement area. Photo 5: Parking area and southern building on opposite side of Baxter. Brownfields Inspection Report: Domestic Lanudry (RN), 25032-21-060 08/18/2022 10:46 AM Page 7 of 7 Photo 6: View facing west of former parking area, and additional building to be razed. Photo 7: There were two areas on eastern portion of property where soil drums were staged. Most of the labels had no writing on them, with some only indicating the boring location. Did not observe any labels with contact info, dates collected, etc.