HomeMy WebLinkAbout18032_Carter Woodson_SIR_20220630 DWM Brownfields Inspection Report Submitted By: jkslaughter_ncdenr Submitted Time: 07/06/2022 7:18 AM I. Inspection Information Date & Time: 06/30/2022 9:40 AM Inspection Type: Meeting Brownfields Staff: Kevin Slaughter, Seth Titley, Tyler Pearson Other Personnel: Conan Fitzgerald - AECOM Location: Lat: 36.0666554, Long: -80.2314058, Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 06/30/2022 9:40 AM Page 2 of 7 II. Project Information Number: 18032-14-034 Name: Carter G. Woodson Charter School Address: 420, 437 Goldfloss St City: Winston Salem County: Forsyth III. Environmental Current Use of Property: Institutional Structures on Property: Existing Structures Violation: No Vapor Mitigation Systems: Observed Vapor Mitigation Violation: No Use of Surface Water or Groundwater: Not Observed Water Use Violation: No Exposed Soils: Not Observed Exposed Soils Violation: No Summary: An active VIMS is installed within the southern school building described above. The system has three fans mounted on the exterior of the western end of the building (Photo 1). Three trunk lines extract air from a combination of suction pits and relatively short sub-slab trenches, most of which can be identified by vinyl floor tiles that have been replaced following the installations (Photos 2 and 3). Liquid filled u-tube manometers, riser labeling, vapor pins, valving and system alarms were visible during the inspection. During the Site Inspection, DEQ requested that AECOM install labels on exterior blower discharge piping. Summary: During the Site Inspection, the future use of creek water for a proposed goat enclosure was mentioned by maintenance staff at the school. This would not be allowed based on Land Use Restrictions (LURU’s) for the property. Summary: During the Site Inspection, the only structure inspected was a newer single story school building located on southern side of Goldfloss St. Summary: N/A Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 06/30/2022 9:40 AM Page 3 of 7 Use of Basements: Not Observed Basement Violation: No Storage of Chemicals: Not Observed Chemical Violation: No Groundwater Monitoring Wells: Not Observed Monitoring Well Violation: No Current Exposure to Public/Public Risk: Summary: N/A Summary: N/A Condition: Summary: N/A Based on vacuum measurements observed within the school building (Photos 4 and 5), the VIMS appears to be generally operating as designed, although two vapor pins on the eastern end of the building had no measurable vacuum influence (Photo 6). This operation of this portion of the VIMS may need to be reevaluated. There are large gardens present on the southwestern portion of the property which are used to grow vegetables (Figure 7). Some areas appear to be slightly raised, while others are not. Although a black fabric material is installed below the soil/mulch layer, it is unknown if this material would prevent roots from the growing from plants above the fabric, into native soil below the fabric. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 06/30/2022 9:40 AM Page 4 of 7 IV. Inspector Comments V. PHOTOGRAPHS Photo 1: Exterior active VIMS fans, exhaust risers, VIMS alarms, and lockable disconnects located on western end of school building. Requested during Site Inspection that AECOM install labels on exterior riser piping. During the Site Inspection, maintenance personnel identified a proposed goat enclosure area as being west of the existing vegetable gardens, and not to the south as shown on Mid-Atlantic’s drawing depicting the proposed location of the goat pen (Photo 7 and attachment). As mentioned previously, utilizing water from the creek to provide water for the goats was mentioned while on-site which would not be allowed under the existing LUR’s for the property. Following the Site Inspection, the goat enclosure, possible use of water from the creek, presence of vegetable gardens and current condition of the VIMS was discussed with the DEQ Project Manager. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 06/30/2022 9:40 AM Page 5 of 7 Photo 2: Example of PVC riser extracting from suction pit located directly below riser as indicated by replacement floor tile. Photo 3: PVC riser on back wall extracting from sub-slab extraction trench. The trench location can be identified from lighter colored replacement floor tiles below desks. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 06/30/2022 9:40 AM Page 6 of 7 Photo 4: Liquid filled U-tube manometers and labeling were installed near the ceiling on each suction riser. Photo 5: Example of vacuum measurement from sub-slab vapor pin located in classroom. Units are in “WC. Brownfields Inspection Report: Carter G. Woodson Charter School, 18032-14-034 06/30/2022 9:40 AM Page 7 of 7 Photo 6: One of two locations (restroom) where no measurable vacuum was measured during the Site Inspection. Photo 7: Facing west across vegetable garden at the proposed goat enclosure location (according to maintenance staff). This location is significantly north of the area identified in a figure prepared by Mid-Atlantic prior to the Site Inspection (attached).